1
|
Yusuf PA, Hubka P, Konerding W, Land R, Tillein J, Kral A. Congenital deafness reduces alpha-gamma cross-frequency coupling in the auditory cortex. Hear Res 2024; 449:109032. [PMID: 38797035 DOI: 10.1016/j.heares.2024.109032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 04/30/2024] [Accepted: 05/13/2024] [Indexed: 05/29/2024]
Abstract
Neurons within a neuronal network can be grouped by bottom-up and top-down influences using synchrony in neuronal oscillations. This creates the representation of perceptual objects from sensory features. Oscillatory activity can be differentiated into stimulus-phase-locked (evoked) and non-phase-locked (induced). The former is mainly determined by sensory input, the latter by higher-level (cortical) processing. Effects of auditory deprivation on cortical oscillations have been studied in congenitally deaf cats (CDCs) using cochlear implant (CI) stimulation. CI-induced alpha, beta, and gamma activity were compromised in the auditory cortex of CDCs. Furthermore, top-down information flow between secondary and primary auditory areas in hearing cats, conveyed by induced alpha oscillations, was lost in CDCs. Here we used the matching pursuit algorithm to assess components of such oscillatory activity in local field potentials recorded in primary field A1. Additionally to the loss of induced alpha oscillations, we also found a loss of evoked theta activity in CDCs. The loss of theta and alpha activity in CDCs can be directly related to reduced high-frequency (gamma-band) activity due to cross-frequency coupling. Here we quantified such cross-frequency coupling in adult 1) hearing-experienced, acoustically stimulated cats (aHCs), 2) hearing-experienced cats following acute pharmacological deafening and subsequent CIs, thus in electrically stimulated cats (eHCs), and 3) electrically stimulated CDCs. We found significant cross-frequency coupling in all animal groups in > 70% of auditory-responsive sites. The predominant coupling in aHCs and eHCs was between theta/alpha phase and gamma power. In CDCs such coupling was lost and replaced by alpha oscillations coupling to delta/theta phase. Thus, alpha/theta oscillations synchronize high-frequency gamma activity only in hearing-experienced cats. The absence of induced alpha and theta oscillations contributes to the loss of induced gamma power in CDCs, thereby signifying impaired local network activity.
Collapse
Affiliation(s)
- Prasandhya A Yusuf
- Hannover Medical School, Institute of AudioNeuroTechnology and Department of Experimental Otology of the ENT Clinics, Hannover, Germany; Faculty of Medicine University of Indonesia, Department of Medical Physiology and Biophysics / Medical Technology IMERI, Jakarta, Indonesia.
| | - Peter Hubka
- Hannover Medical School, Institute of AudioNeuroTechnology and Department of Experimental Otology of the ENT Clinics, Hannover, Germany
| | - Wiebke Konerding
- Hannover Medical School, Institute of AudioNeuroTechnology and Department of Experimental Otology of the ENT Clinics, Hannover, Germany
| | - Rüdiger Land
- Hannover Medical School, Institute of AudioNeuroTechnology and Department of Experimental Otology of the ENT Clinics, Hannover, Germany
| | - Jochen Tillein
- J.W. Goethe University, Department of Otorhinolaryngology, Frankfurt am Main, Germany
| | - Andrej Kral
- Hannover Medical School, Institute of AudioNeuroTechnology and Department of Experimental Otology of the ENT Clinics, Hannover, Germany; Australian Hearing Hub, School of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| |
Collapse
|
2
|
Adenis V, Partouche E, Stahl P, Gnansia D, Huetz C, Edeline JM. Asymmetric pulses delivered by a cochlear implant allow a reduction in evoked firing rate and in spatial activation in the guinea pig auditory cortex. Hear Res 2024; 447:109027. [PMID: 38723386 DOI: 10.1016/j.heares.2024.109027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 04/30/2024] [Accepted: 05/02/2024] [Indexed: 05/25/2024]
Abstract
Despite that fact that the cochlear implant (CI) is one of the most successful neuro-prosthetic devices which allows hearing restoration, several aspects still need to be improved. Interactions between stimulating electrodes through current spread occurring within the cochlea drastically limit the number of discriminable frequency channels and thus can ultimately result in poor speech perception. One potential solution relies on the use of new pulse shapes, such as asymmetric pulses, which can potentially reduce the current spread within the cochlea. The present study characterized the impact of changing electrical pulse shapes from the standard biphasic symmetric to the asymmetrical shape by quantifying the evoked firing rate and the spatial activation in the guinea pig primary auditory cortex (A1). At a fixed charge, the firing rate and the spatial activation in A1 decreased by 15 to 25 % when asymmetric pulses were used to activate the auditory nerve fibers, suggesting a potential reduction of the spread of excitation inside the cochlea. A strong "polarity-order" effect was found as the reduction was more pronounced when the first phase of the pulse was cathodic with high amplitude. These results suggest that the use of asymmetrical pulse shapes in clinical settings can potentially reduce the channel interactions in CI users.
Collapse
Affiliation(s)
- V Adenis
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - E Partouche
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - P Stahl
- Oticon Medical, Vallauris, France
| | | | - C Huetz
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France
| | - J-M Edeline
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), France; CNRS UMR 9197, 91405 Orsay cedex, France; Université Paris-Saclay, 91405 Orsay cedex, France.
| |
Collapse
|
3
|
Quass GL, Kral A. Tripolar configuration and pulse shape in cochlear implants reduce channel interactions in the temporal domain. Hear Res 2024; 443:108953. [PMID: 38277881 DOI: 10.1016/j.heares.2024.108953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 01/08/2024] [Accepted: 01/11/2024] [Indexed: 01/28/2024]
Abstract
The present study investigates effects of current focusing and pulse shape on threshold, dynamic range, spread of excitation and channel interaction in the time domain using cochlear implant stimulation. The study was performed on 20 adult guinea pigs using a 6-channel animal cochlear implant, recording was performed in the auditory midbrain using a multielectrode array. After determining the best frequencies for individual recording contacts with acoustic stimulation, the ear was deafened and a cochlear implant was inserted into the cochlea. The position of the implant was controlled by x-ray. Stimulation with biphasic, pseudomonophasic and monophasic stimuli was performed with monopolar, monopolar with common ground, bipolar and tripolar configuration in two sets of experiments, allowing comparison of the effects of the different stimulation strategies on threshold, dynamic range, spread of excitation and channel interaction. Channel interaction was studied in the temporal domain, where two electrodes were activated with pulse trains and phase locking to these pulse trains in the midbrain was quantified. The results documented multifactorial influences on the response properties, with significant interaction between factors. Thresholds increased with increasing current focusing, but decreased with pseudomonophasic and monophasic pulse shapes. The results documented that current focusing, particularly tripolar configuration, effectively reduces channel interaction, but that also pseudomonophasic and monophasic stimulation and phase duration intensity coding reduce channel interactions.
Collapse
Affiliation(s)
- Gunnar L Quass
- Institute for AudioNeuroTechnology (VIANNA) & Department of Experimental Otology, Otolaryngology Clinics, Hannover Medical School, Hannover, Germany; Cluster of Excellence "Hearing4All" (EXC 2177), Germany.
| | - Andrej Kral
- Institute for AudioNeuroTechnology (VIANNA) & Department of Experimental Otology, Otolaryngology Clinics, Hannover Medical School, Hannover, Germany; Cluster of Excellence "Hearing4All" (EXC 2177), Germany; Australian Hearing Hub, School of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| |
Collapse
|
4
|
Schvartz-Leyzac KC, Colesa DJ, Swiderski DL, Raphael Y, Pfingst BE. Cochlear Health and Cochlear-implant Function. J Assoc Res Otolaryngol 2023; 24:5-29. [PMID: 36600147 PMCID: PMC9971430 DOI: 10.1007/s10162-022-00882-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 11/24/2022] [Indexed: 01/06/2023] Open
Abstract
The cochlear implant (CI) is widely considered to be one of the most innovative and successful neuroprosthetic treatments developed to date. Although outcomes vary, CIs are able to effectively improve hearing in nearly all recipients and can substantially improve speech understanding and quality of life for patients with significant hearing loss. A wealth of research has focused on underlying factors that contribute to success with a CI, and recent evidence suggests that the overall health of the cochlea could potentially play a larger role than previously recognized. This article defines and reviews attributes of cochlear health and describes procedures to evaluate cochlear health in humans and animal models in order to examine the effects of cochlear health on performance with a CI. Lastly, we describe how future biologic approaches can be used to preserve and/or enhance cochlear health in order to maximize performance for individual CI recipients.
Collapse
Affiliation(s)
- Kara C Schvartz-Leyzac
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge Ave, Charleston, SC, 29425, USA
| | - Deborah J Colesa
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Donald L Swiderski
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Yehoash Raphael
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Bryan E Pfingst
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA.
| |
Collapse
|
5
|
Partouche E, Adenis V, Stahl P, Huetz C, Edeline JM. What Is the Benefit of Ramped Pulse Shapes for Activating Auditory Cortex Neurons? An Electrophysiological Study in an Animal Model of Cochlear Implant. Brain Sci 2023; 13:brainsci13020250. [PMID: 36831793 PMCID: PMC9954719 DOI: 10.3390/brainsci13020250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 01/19/2023] [Accepted: 01/30/2023] [Indexed: 02/04/2023] Open
Abstract
In all commercial cochlear implant (CI) devices, the activation of auditory nerve fibers is performed with rectangular pulses that have two phases of opposite polarity. Recently, several papers proposed that ramped pulse shapes could be an alternative shape for efficiently activating auditory nerve fibers. Here, we investigate whether ramped pulse shapes can activate auditory cortex (ACx) neurons in a more efficient way than the classical rectangular pulses. Guinea pigs were implanted with CI devices and responses of ACx neurons were tested with rectangular pulses and with four ramped pulse shapes, with a first-phase being either cathodic or anodic. The thresholds, i.e., the charge level necessary for obtaining significant cortical responses, were almost systematically lower with ramped pulses than with rectangular pulses. The maximal firing rate (FR) elicited by the ramped pulses was higher than with rectangular pulses. As the maximal FR occurred with lower charge levels, the dynamic range (between threshold and the maximal FR) was not modified. These effects were obtained with cathodic and anodic ramped pulses. By reducing the charge levels required to activate ACx neurons, the ramped pulse shapes should reduce charge consumption and should contribute to more battery-efficient CI devices in the future.
Collapse
Affiliation(s)
- Elie Partouche
- Jean-Marc Edeline Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, Campus CEA Saclay, Route de la Rotonde Bâtiment 151, 91400 Saclay, France
| | - Victor Adenis
- Jean-Marc Edeline Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, Campus CEA Saclay, Route de la Rotonde Bâtiment 151, 91400 Saclay, France
| | - Pierre Stahl
- Departement of Scientific and Clinical Research, Oticon Medical, 06220 Vallauris, France
| | - Chloé Huetz
- Jean-Marc Edeline Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, Campus CEA Saclay, Route de la Rotonde Bâtiment 151, 91400 Saclay, France
| | - Jean-Marc Edeline
- Jean-Marc Edeline Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, Campus CEA Saclay, Route de la Rotonde Bâtiment 151, 91400 Saclay, France
- Correspondence:
| |
Collapse
|
6
|
Summating Potential as Marker of Intracochlear Position in Bipolar Electrocochleography. Ear Hear 2023; 44:118-134. [PMID: 35894668 DOI: 10.1097/aud.0000000000001259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVES Cochlear implantation criteria include subjects with residual low-frequency hearing. To minimize implantation trauma and to avoid unwanted interactions of electric- and acoustic stimuli, it is often recommended to stop cochlear implantation before the cochlear implant (CI) reaches the cochlear partition with residual hearing, as determined by an audiogram. For this purpose, the implant can be used to record acoustically evoked signals during implantation, including cochlear compound action potentials (CAP), cochlear microphonics (CMs), and summating potentials (SPs). The former two have previously been used to monitor residual hearing in clinical settings. DESIGN In the present study we investigated the use of intracochlear, bipolar SP recordings to determine the exact cochlear position of the contacts of implanted CIs in guinea pig cochleae (n = 13). Polarity reversals of SPs were used as a functional marker of intracochlear position. Micro computed tomography (µCT) imaging and a modified Greenwood function were used to determine the cochleotopic positions of the contacts in the cochlea. These anatomical reconstructions were used to validate the SP-based position estimates. RESULTS The precision of the SP-based position estimation was on average within ± 0.37 octaves and was not impaired by moderate hearing loss caused by noise exposure after implantation. It is important to note that acute hearing impairment did not reduce the precision of the method. The cochleotopic position of CI accounted for ~70% of the variability of SP polarity reversals. Outliers in the dataset were associated with lateral CI positions. Last, we propose a simplified method to avoid implantation in functioning parts of the cochlea by approaching a predefined frequency region using bipolar SP recordings through a CI. CONCLUSIONS Bipolar SP recordings provide reliable information on electrode position in the cochlea. The position estimate remains reliable after moderate hearing loss. The technique presented here could be applied during CI surgery to monitor the CI approach to a predefined frequency region.
Collapse
|
7
|
Kipping D, Nogueira W. A Computational Model of a Single Auditory Nerve Fiber for Electric-Acoustic Stimulation. J Assoc Res Otolaryngol 2022; 23:835-858. [PMID: 36333573 PMCID: PMC9789289 DOI: 10.1007/s10162-022-00870-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Accepted: 08/21/2022] [Indexed: 11/06/2022] Open
Abstract
Cochlear implant (CI) recipients with preserved acoustic low-frequency hearing in the implanted ear are a growing group among traditional CI users who benefit from hybrid electric-acoustic stimulation (EAS). However, combined ipsilateral electric and acoustic stimulation also introduces interactions between the two modalities that can affect the performance of EAS users. A computational model of a single auditory nerve fiber that is excited by EAS was developed to study the interaction between electric and acoustic stimulation. Two existing models of sole electric or acoustic stimulation were coupled to simulate responses to combined EAS. Different methods of combining both models were implemented. In the coupled model variant, the refractoriness of the simulated fiber leads to suppressive interaction between electrically evoked and acoustically evoked spikes as well as spontaneous activity. The second model variant is an uncoupled EAS model without electric-acoustic interaction. By comparing predictions between the coupled and the noninteracting EAS model, it was possible to infer electric-acoustic interaction at the level of the auditory nerve. The EAS model was used to simulate fiber populations with realistic inter-unit variability, where each unit was represented by the single-fiber model. Predicted thresholds and dynamic ranges, spike rates, latencies, jitter, and vector strengths were compared to empirical data. The presented EAS model provides a framework for future studies of peripheral electric-acoustic interaction.
Collapse
Affiliation(s)
- Daniel Kipping
- Department of Otolaryngology, Hannover Medical School (MHH), Hannover, Germany
- Cluster of Excellence Hearing4all, Hannover, Germany
| | - Waldo Nogueira
- Department of Otolaryngology, Hannover Medical School (MHH), Hannover, Germany
- Cluster of Excellence Hearing4all, Hannover, Germany
| |
Collapse
|
8
|
Montes-Lourido P, Kar M, Pernia M, Parida S, Sadagopan S. Updates to the guinea pig animal model for in-vivo auditory neuroscience in the low-frequency hearing range. Hear Res 2022; 424:108603. [PMID: 36099806 PMCID: PMC9922531 DOI: 10.1016/j.heares.2022.108603] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 08/29/2022] [Accepted: 09/03/2022] [Indexed: 02/08/2023]
Abstract
For gaining insight into general principles of auditory processing, it is critical to choose model organisms whose set of natural behaviors encompasses the processes being investigated. This reasoning has led to the development of a variety of animal models for auditory neuroscience research, such as guinea pigs, gerbils, chinchillas, rabbits, and ferrets; but in recent years, the availability of cutting-edge molecular tools and other methodologies in the mouse model have led to waning interest in these unique model species. As laboratories increasingly look to include in-vivo components in their research programs, a comprehensive description of procedures and techniques for applying some of these modern neuroscience tools to a non-mouse small animal model would enable researchers to leverage unique model species that may be best suited for testing their specific hypotheses. In this manuscript, we describe in detail the methods we have developed to apply these tools to the guinea pig animal model to answer questions regarding the neural processing of complex sounds, such as vocalizations. We describe techniques for vocalization acquisition, behavioral testing, recording of auditory brainstem responses and frequency-following responses, intracranial neural signals including local field potential and single unit activity, and the expression of transgenes allowing for optogenetic manipulation of neural activity, all in awake and head-fixed guinea pigs. We demonstrate the rich datasets at the behavioral and electrophysiological levels that can be obtained using these techniques, underscoring the guinea pig as a versatile animal model for studying complex auditory processing. More generally, the methods described here are applicable to a broad range of small mammals, enabling investigators to address specific auditory processing questions in model organisms that are best suited for answering them.
Collapse
Affiliation(s)
- Pilar Montes-Lourido
- Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Center for Neuroscience, University of Pittsburgh, Pittsburgh, PA, USA
| | - Manaswini Kar
- Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Center for Neuroscience, University of Pittsburgh, Pittsburgh, PA, USA; Center for the Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, USA
| | - Marianny Pernia
- Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Center for Neuroscience, University of Pittsburgh, Pittsburgh, PA, USA
| | - Satyabrata Parida
- Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Center for Neuroscience, University of Pittsburgh, Pittsburgh, PA, USA
| | - Srivatsun Sadagopan
- Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Center for Neuroscience, University of Pittsburgh, Pittsburgh, PA, USA; Center for the Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Department of Communication Science and Disorders, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
9
|
Yusuf PA, Lamuri A, Hubka P, Tillein J, Vinck M, Kral A. Deficient Recurrent Cortical Processing in Congenital Deafness. Front Syst Neurosci 2022; 16:806142. [PMID: 35283734 PMCID: PMC8913535 DOI: 10.3389/fnsys.2022.806142] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Accepted: 01/13/2022] [Indexed: 12/14/2022] Open
Abstract
The influence of sensory experience on cortical feedforward and feedback interactions has rarely been studied in the auditory cortex. Previous work has documented a dystrophic effect of deafness in deep cortical layers, and a reduction of interareal couplings between primary and secondary auditory areas in congenital deafness which was particularly pronounced in the top-down direction (from the secondary to the primary area). In the present study, we directly quantified the functional interaction between superficial (supragranular, I to III) and deep (infragranular, V and VI) layers of feline’s primary auditory cortex A1, and also between superficial/deep layers of A1 and a secondary auditory cortex, namely the posterior auditory field (PAF). We compared adult hearing cats under acoustic stimulation and cochlear implant (CI) stimulation to adult congenitally deaf cats (CDC) under CI stimulation. Neuronal activity was recorded from auditory fields A1 and PAF simultaneously with two NeuroNexus electrode arrays. We quantified the spike field coherence (i.e., the statistical dependence of spike trains at one electrode with local field potentials on another electrode) using pairwise phase consistency (PPC). Both the magnitude as well as the preferred phase of synchronization was analyzed. The magnitude of PPC was significantly smaller in CDCs than in controls. Furthermore, controls showed no significant difference between the preferred phase of synchronization between supragranular and infragranular layers, both in acoustic and electric stimulation. In CDCs, however, there was a large difference in the preferred phase between supragranular and infragranular layers. These results demonstrate a loss of synchrony and for the first time directly document a functional decoupling of the interaction between supragranular and infragranular layers of the primary auditory cortex in congenital deafness. Since these are key for the influence of top-down to bottom-up computations, the results suggest a loss of recurrent cortical processing in congenital deafness and explain the outcomes of previous studies by deficits in intracolumnar microcircuitry.
Collapse
Affiliation(s)
- Prasandhya Astagiri Yusuf
- Department of Medical Physics/Medical Technology IMERI, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia
| | - Aly Lamuri
- Department of Medical Physics/Medical Technology IMERI, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia
| | - Peter Hubka
- Institute of AudioNeuroTechnology and Department of Experimental Otology of the ENT Clinics, Hannover Medical School, Hanover, Germany
| | - Jochen Tillein
- Institute of AudioNeuroTechnology and Department of Experimental Otology of the ENT Clinics, Hannover Medical School, Hanover, Germany
- MEDEL Comp., Starnberg, Germany
| | - Martin Vinck
- Ernst Strüngmann Institut for Neuroscience in Cooperation with Max Planck Society, Frankfurt am Main, Germany
- Donders Centre for Neuroscience, Department of Neuroinformatics, Radboud University Nijmegen, Nijmegen, Netherlands
| | - Andrej Kral
- Institute of AudioNeuroTechnology and Department of Experimental Otology of the ENT Clinics, Hannover Medical School, Hanover, Germany
- Department of Biomedical Sciences, School of Medicine and Health Sciences, Macquarie University, Sydney, NSW, Australia
| |
Collapse
|
10
|
Partouche E, Adenis V, Gnansia D, Stahl P, Edeline JM. Increased Threshold and Reduced Firing Rate of Auditory Cortex Neurons after Cochlear Implant Insertion. Brain Sci 2022; 12:brainsci12020205. [PMID: 35203968 PMCID: PMC8870646 DOI: 10.3390/brainsci12020205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 01/25/2022] [Accepted: 01/28/2022] [Indexed: 12/10/2022] Open
Abstract
The cochlear implant (CI) is the most successful neuroprosthesis allowing thousands of patients with profound hearing loss to recover speech understanding. Recently, cochlear implants have been proposed to subjects with residual hearing and, in these cases, shorter CIs were implanted. To be successful, it is crucial to preserve the patient’s remaining hearing abilities after the implantation. Here, we quantified the effects of CI insertion on the responses of auditory cortex neurons in anesthetized guinea pigs. The responses of auditory cortex neurons were determined before and after the insertion of a 300 µm diameter CI (six stimulating electrodes, length 6 mm). Immediately after CI insertion there was a 5 to 15 dB increase in the threshold for cortical neurons from the middle to the high frequencies, accompanied by a decrease in the evoked firing rate. Analyzing the characteristic frequency (CF) values revealed that in large number of cases, the CFs obtained after insertion were lower than before. These effects were not detected in the control animals. These results indicate that there is a small but immediate cortical hearing loss after CI insertion, even with short length CIs. Therefore, efforts should be made to minimize the damages during CI insertion to preserve the cortical responses to acoustic stimuli.
Collapse
Affiliation(s)
- Elie Partouche
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, 91400 Saclay, France; (E.P.); (V.A.)
| | - Victor Adenis
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, 91400 Saclay, France; (E.P.); (V.A.)
| | - Dan Gnansia
- Department of Scientific and Clinical Research, Oticon Medical, 06224 Vallauris, France; (D.G.); (P.S.)
| | - Pierre Stahl
- Department of Scientific and Clinical Research, Oticon Medical, 06224 Vallauris, France; (D.G.); (P.S.)
| | - Jean-Marc Edeline
- Paris-Saclay Institute of Neurosciences (Neuro-PSI), CNRS UMR 9197, Universite Paris-Saclay, 91400 Saclay, France; (E.P.); (V.A.)
- Correspondence:
| |
Collapse
|
11
|
Suh MW, Tran P, Richardson M, Sun S, Xu Y, Djalilian HR, Lin HW, Zeng FG. Electric hearing and tinnitus suppression by noninvasive ear stimulation. Hear Res 2022; 415:108431. [PMID: 35016022 DOI: 10.1016/j.heares.2022.108431] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 12/22/2021] [Accepted: 01/04/2022] [Indexed: 11/04/2022]
Abstract
While noninvasive brain stimulation is convenient and cost effective, its utility is limited by the substantial distance between scalp electrodes and their intended neural targets in the head. The tympanic membrane, or eardrum, is a thin flap of skin deep in an orifice of the head that may serve as a port for improved efficiency of noninvasive stimulation. Here we chose the cochlea as a target because it resides in the densest bone of the skull and is adjacent to many deep-brain-stimulation structures. We also tested the hypothesis that noninvasive electric stimulation of the cochlea may restore neural activities that are missing in acoustic stimulation. We placed an electrode in the ear canal or on the tympanic membrane in 25 human adults (10 females) and compared their stimulation efficiency by characterizing the electrically-evoked auditory sensation. Relative to ear canal stimulation, tympanic membrane stimulation was four times more likely to produce an auditory percept, required eight times lower electric current to reach the threshold and produced two-to-four times more linear suprathreshold responses. We further measured tinnitus suppression in 14 of the 25 subjects who had chronic tinnitus. Compared with ear canal stimulation, tympanic membrane stimulation doubled both the probability (22% vs. 55%) and the amount (-15% vs. -34%) of tinnitus suppression. These findings extended previous work comparing evoked perception and tinnitus suppression between electrodes placed in the ear canal and on the scalp. Together, the previous and present results suggest that the efficiency of conventional scalp-based noninvasive electric stimulation can be improved by at least one order of magnitude via tympanic membrane stimulation. This increased efficiency is most likely due to the shortened distance between the electrode placed on the tympanic membrane and the targeted cochlea. The present findings have implications for the management of tinnitus by offering a potential alternative to interventions using invasive electrical stimulation such as cochlear implantation, or other non-invasive transcranial electrical stimulation methods.
Collapse
Affiliation(s)
- Myung-Whan Suh
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, CA 92697, United States; Department of Otorhinolaryngology - Head and Neck Surgery, Seoul National University Hospital, Seoul, South Korea
| | - Phillip Tran
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, CA 92697, United States
| | - Matthew Richardson
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, CA 92697, United States
| | - Shuping Sun
- Department of Otolaryngology - Head and Neck Surgery, The First Affiliated Hospital, Zhengzhou University, Henan 450052, China
| | - Yuchen Xu
- Department of Bioengineering, University of California San Diego, San Diego, California 92092, United States
| | - Hamid R Djalilian
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, CA 92697, United States
| | - Harrison W Lin
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, CA 92697, United States
| | - Fan-Gang Zeng
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, CA 92697, United States.
| |
Collapse
|
12
|
Zhang Q, Ota T, Yoshida T, Ino D, Sato MP, Doi K, Horii A, Nin F, Hibino H. Electrochemical properties of the non-excitable tissue stria vascularis of the mammalian cochlea are sensitive to sounds. J Physiol 2021; 599:4497-4516. [PMID: 34426971 DOI: 10.1113/jp281981] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 08/18/2021] [Indexed: 11/08/2022] Open
Abstract
Excitable cochlear hair cells convert the mechanical energy of sounds into the electrical signals necessary for neurotransmission. The key process is cellular depolarization via K+ entry from K+ -enriched endolymph through hair cells' mechanosensitive channels. Positive 80 mV potential in endolymph accelerates the K+ entry, thereby sensitizing hearing. This potential represents positive extracellular potential within the epithelial-like stria vascularis; the latter potential stems from K+ equilibrium potential (EK ) across the strial membrane. Extra- and intracellular [K+ ] determining EK are likely maintained by continuous unidirectional circulation of K+ through a putative K+ transport pathway containing hair cells and stria. Whether and how the non-excitable tissue stria vascularis responds to acoustic stimuli remains unclear. Therefore, we analysed a cochlear portion for the best frequency, 1 kHz, by theoretical and experimental approaches. We have previously developed a computational model that integrates ion channels and transporters in the stria and hair cells into a circuit and described a circulation current composed of K+ . Here, in this model, mimicking of hair cells' K+ flow induced by a 1 kHz sound modulated the circulation current and affected the strial ion transport mechanisms; the latter effect resulted in monotonically decreasing potential and increasing [K+ ] in the extracellular strial compartment. Similar results were obtained when the stria in acoustically stimulated animals was examined using microelectrodes detecting the potential and [K+ ]. Measured potential dynamics mirrored the EK change. Collectively, because stria vascularis is electrically coupled to hair cells by the circulation current in vivo too, the strial electrochemical properties respond to sounds. KEY POINTS: A highly positive potential of +80 mV in K+ -enriched endolymph in the mammalian cochlea accelerates sound-induced K+ entry into excitable sensory hair cells, a process that triggers hearing. This unique endolymphatic potential represents an EK -based battery for a non-excitable epithelial-like tissue, the stria vascularis. To examine whether and how the stria vascularis responds to sounds, we used our computational model, in which strial channels and transporters are serially connected to those hair cells in a closed-loop circuit, and found that mimicking hair cell excitation by acoustic stimuli resulted in increased extracellular [K+ ] and decreased the battery's potential within the stria. This observation was overall verified by electrophysiological experiments using live guinea pigs. The sensitivity of electrochemical properties of the stria to sounds indicates that this tissue is electrically coupled to hair cells by a radial ionic flow called a circulation current.
Collapse
Affiliation(s)
- Qi Zhang
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.,Department of Molecular Physiology, Niigata University Graduate School of Medical and Dental Sciences, Asahimachi-dori, Niigata, Japan.,Department of Otolaryngology Head and Neck Surgery, Niigata University Graduate School of Medical and Dental Sciences, Asahimachi-dori, Niigata, Japan
| | - Takeru Ota
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Takamasa Yoshida
- Department of Otorhinolaryngology, Graduate School of Medical Sciences, Kyushu University, Maidashi, Fukuoka, Japan
| | - Daisuke Ino
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Mitsuo P Sato
- Department of Otolaryngology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Katsumi Doi
- Department of Otolaryngology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Arata Horii
- Department of Otolaryngology Head and Neck Surgery, Niigata University Graduate School of Medical and Dental Sciences, Asahimachi-dori, Niigata, Japan
| | - Fumiaki Nin
- Department of Physiology, Division of Biological Principles, Graduate School of Medicine, Gifu University, Yanagido, Gifu, Japan
| | - Hiroshi Hibino
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.,AMED, AMED-CREST, Osaka, Japan
| |
Collapse
|
13
|
Zhang C, Li Q, Chen M, Lu T, Min S, Li S. The role of oxidative stress in the susceptibility of noise-impaired cochleae to synaptic loss induced by intracochlear electrical stimulation. Neuropharmacology 2021; 196:108707. [PMID: 34246683 DOI: 10.1016/j.neuropharm.2021.108707] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 06/15/2021] [Accepted: 07/06/2021] [Indexed: 11/20/2022]
Abstract
Intracochlear electrical stimulation (ES) generated by cochlear implants (CIs) is used to activate auditory nerves to restore hearing perception in deaf subjects and those with residual hearing who use electroacoustic stimulation (EAS) technology. Approximately 1/3 of EAS recipients experience loss of residual hearing a few months after ES activation, but the underlying mechanism is unknown. Clinical evidence indicates that the loss is related to the previous history of noise-induced hearing loss (NIHL). In this report, we investigated the impact of intracochlear ES on oxidative stress levels and synaptic counts in inner hair cells (IHCs) of the apical, middle and basal regions of guinea pigs with normal hearing (NH) and NIHL. Our results demonstrated that intracochlear ES with an intensity of 6 dB above the thresholds of electrically evoked compound action potentials (ECAPs) could induce the elevation of oxidative stress levels, resulting in a loss of IHC synapses near the electrodes in the basal and middle regions of the NH cochleae. Furthermore, the apical region of cochleae with NIHL were more susceptible to synaptic loss induced by relatively low-intensity ES than that of NH cochleae, resulting from the additional elevation of oxidative stress levels and the reduced antioxidant capability throughout the whole cochlea.
Collapse
Affiliation(s)
- Chen Zhang
- Department of Otolaryngology - Head and Neck Surgery, Eye & ENT Hospital of Fudan University, Shanghai, 200031, China; NHC Key Laboratory of Hearing Medicine, Shanghai, China
| | - Qiang Li
- Department of Otolaryngology - Head and Neck Surgery, Eye & ENT Hospital of Fudan University, Shanghai, 200031, China; NHC Key Laboratory of Hearing Medicine, Shanghai, China
| | - Min Chen
- Department of Otolaryngology - Head and Neck Surgery, Eye & ENT Hospital of Fudan University, Shanghai, 200031, China; NHC Key Laboratory of Hearing Medicine, Shanghai, China
| | - Tianhao Lu
- Department of Otolaryngology - Head and Neck Surgery, Eye & ENT Hospital of Fudan University, Shanghai, 200031, China; NHC Key Laboratory of Hearing Medicine, Shanghai, China
| | - Shiyao Min
- Department of Otolaryngology - Head and Neck Surgery, Eye & ENT Hospital of Fudan University, Shanghai, 200031, China; NHC Key Laboratory of Hearing Medicine, Shanghai, China
| | - Shufeng Li
- Department of Otolaryngology - Head and Neck Surgery, Eye & ENT Hospital of Fudan University, Shanghai, 200031, China; NHC Key Laboratory of Hearing Medicine, Shanghai, China.
| |
Collapse
|
14
|
Buchman CA, Gifford RH, Haynes DS, Lenarz T, O'Donoghue G, Adunka O, Biever A, Briggs RJ, Carlson ML, Dai P, Driscoll CL, Francis HW, Gantz BJ, Gurgel RK, Hansen MR, Holcomb M, Karltorp E, Kirtane M, Larky J, Mylanus EAM, Roland JT, Saeed SR, Skarzynski H, Skarzynski PH, Syms M, Teagle H, Van de Heyning PH, Vincent C, Wu H, Yamasoba T, Zwolan T. Unilateral Cochlear Implants for Severe, Profound, or Moderate Sloping to Profound Bilateral Sensorineural Hearing Loss: A Systematic Review and Consensus Statements. JAMA Otolaryngol Head Neck Surg 2021; 146:942-953. [PMID: 32857157 DOI: 10.1001/jamaoto.2020.0998] [Citation(s) in RCA: 67] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Importance Cochlear implants are a treatment option for individuals with severe, profound, or moderate sloping to profound bilateral sensorineural hearing loss (SNHL) who receive little or no benefit from hearing aids; however, cochlear implantation in adults is still not routine. Objective To develop consensus statements regarding the use of unilateral cochlear implants in adults with severe, profound, or moderate sloping to profound bilateral SNHL. Design, Setting, and Participants This study was a modified Delphi consensus process that was informed by a systematic review of the literature and clinical expertise. Searches were conducted in the following databases: (1) MEDLINE In-Process & Other Non-Indexed Citations and Ovid MEDLINE, (2) Embase, and (3) the Cochrane Library. Consensus statements on cochlear implantation were developed using the evidence identified. This consensus process was relevant for the use of unilateral cochlear implantation in adults with severe, profound, or moderate sloping to profound bilateral SNHL. The literature searches were conducted on July 18, 2018, and the 3-step Delphi consensus method took place over the subsequent 9-month period up to March 30, 2019. Main Outcomes and Measures A Delphi consensus panel of 30 international specialists voted on consensus statements about cochlear implantation, informed by an SR of the literature and clinical expertise. This vote resulted in 20 evidence-based consensus statements that are in line with clinical experience. A modified 3-step Delphi consensus method was used to vote on and refine the consensus statements. This method consisted of 2 rounds of email questionnaires and a face-to-face meeting of panel members at the final round. All consensus statements were reviewed, discussed, and finalized at the face-to-face meeting. Results In total, 6492 articles were identified in the searches of the electronic databases. After removal of duplicate articles, 74 articles fulfilled all of the inclusion criteria and were used to create the 20 evidence-based consensus statements. These 20 consensus statements on the use of unilateral cochlear implantation in adults with SNHL were relevant to the following 7 key areas of interest: level of awareness of cochlear implantation (1 consensus statement); best practice clinical pathway from diagnosis to surgery (3 consensus statements); best practice guidelines for surgery (2 consensus statements); clinical effectiveness of cochlear implantation (4 consensus statements); factors associated with postimplantation outcomes (4 consensus statements); association between hearing loss and depression, cognition, and dementia (5 consensus statements); and cost implications of cochlear implantation (1 consensus statement). Conclusions and Relevance These consensus statements represent the first step toward the development of international guidelines on best practices for cochlear implantation in adults with SNHL. Further research to develop consensus statements for unilateral cochlear implantation in children, bilateral cochlear implantation, combined electric-acoustic stimulation, unilateral cochlear implantation for single-sided deafness, and asymmetrical hearing loss in children and adults may be beneficial for optimizing hearing and quality of life for these patients.
Collapse
Affiliation(s)
- Craig A Buchman
- Department of Otolaryngology-Head and Neck Surgery, Washington University School of Medicine in St Louis, St Louis, Missouri
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - David S Haynes
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
| | - Gerard O'Donoghue
- Department of Otology and Neurotology, University of Nottingham, Nottingham, United Kingdom.,Nottingham Biomedical Research Center, Nottingham University Hospitals National Health Service (NHS) Trust, Nottingham, United Kingdom
| | - Oliver Adunka
- Ohio State University Wexner Medical Center, The Ohio State University, Columbus
| | | | - Robert J Briggs
- Department of Otolaryngology, The University of Melbourne, Melbourne, Victoria, Australia.,Otology and Cochlear Implant Clinic, Royal Victorian Eye and Ear Hospital, Melbourne, Victoria, Australia.,Department of Surgery, Royal Melbourne Hospital, Melbourne, Victoria, Australia
| | - Matthew L Carlson
- Department of Otorhinolaryngology, Mayo Clinic School of Medicine, Rochester, Minnesota
| | - Pu Dai
- Department of Otolaryngology, General Hospital of People's Liberation Army, Beijing, China
| | - Colin L Driscoll
- Department of Otorhinolaryngology, Mayo Clinic School of Medicine, Rochester, Minnesota
| | - Howard W Francis
- Division of Head and Neck Surgery and Communication Sciences, Duke Surgery, Duke University School of Medicine, Durham, North Carolina
| | - Bruce J Gantz
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa, Iowa City
| | - Richard K Gurgel
- Division of Otolaryngology-Head & Neck Surgery, School of Medicine, University of Utah Hospital, Salt Lake City
| | - Marlan R Hansen
- Department of Otolaryngology-Head and Neck Surgery, University of Iowa, Iowa City
| | - Meredith Holcomb
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston.,now with Department of Otolaryngology, University of Miami, Miami, Florida
| | - Eva Karltorp
- Cochlear Implant Department, Karolinska University Hospital, Stockholm, Sweden
| | - Milind Kirtane
- Department of ENT and Head Neck Surgery, Seth Gordhandas Sunderdas Medical College, King Edward Memorial Hospital, Mumbai, India
| | - Jannine Larky
- Cochlear Implant Center, Stanford University School of Medicine, Stanford, California
| | - Emmanuel A M Mylanus
- Department of Ear Nose Throat, Radboud University Medical Centre, Nijmegen, the Netherlands
| | - J Thomas Roland
- NYU Langone Health, New York University School of Medicine, New York
| | - Shakeel R Saeed
- Royal National Throat, Nose and Ear Hospital and University College London Ear Institute, London, United Kingdom
| | - Henryk Skarzynski
- Institute of Physiology and Pathology of Hearing, World Hearing Center, Kajetany, Nadarzyn, Poland
| | - Piotr H Skarzynski
- Institute of Physiology and Pathology of Hearing, World Hearing Center, Kajetany, Nadarzyn, Poland.,Faculty of Medicine, Medical University of Warsaw, Warsaw, Poland.,Institute of Sensory Organs, Kajetany, Nadarzyn, Poland
| | | | - Holly Teagle
- School of Population Health-Audiology, The University of Auckland, Auckland, New Zealand
| | - Paul H Van de Heyning
- Department NKO & Head-Neck Surgery, Antwerp University Hospital, University of Antwerp, Edegem, Belgium
| | - Christophe Vincent
- Service d'Otologie et Oto-Neurologie, Centre Hospitalier Universitaire de Lille, Lille, France
| | - Hao Wu
- Department of Otolaryngology-Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Tatsuya Yamasoba
- Department of Otorhinolaryngology and Auditory and Voice Surgery, University of Tokyo Hospital, Tokyo, Japan
| | - Terry Zwolan
- Department of Otolaryngology-Head and Neck Surgery, University of Michigan, Ann Arbor
| |
Collapse
|
15
|
Foremny K, Konerding WS, Behrens A, Baumhoff P, Froriep UP, Kral A, Doll T. Carbon-Nanotube-Coated Surface Electrodes for Cortical Recordings In Vivo. NANOMATERIALS 2021; 11:nano11041029. [PMID: 33920671 PMCID: PMC8073035 DOI: 10.3390/nano11041029] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 04/12/2021] [Accepted: 04/15/2021] [Indexed: 11/16/2022]
Abstract
Current developments of electrodes for neural recordings address the need of biomedical research and applications for high spatial acuity in electrophysiological recordings. One approach is the usage of novel materials to overcome electrochemical constraints of state-of-the-art metal contacts. Promising materials are carbon nanotubes (CNTs), as they are well suited for neural interfacing. The CNTs increase the effective contact surface area to decrease high impedances while keeping minimal contact diameters. However, to prevent toxic dissolving of CNTs, an appropriate surface coating is required. In this study, we tested flexible surface electrocorticographic (ECoG) electrodes, coated with a CNT-silicone rubber composite. First, we describe the outcome of surface etching, which exposes the contact nanostructure while anchoring the CNTs. Subsequently, the ECoG electrodes were used for acute in vivo recordings of auditory evoked potentials from the guinea pig auditory cortex. Both the impedances and the signal-to-noise ratios of coated contacts were similar to uncoated gold contacts. This novel approach for a safe application of CNTs, embedded in a surface etched silicone rubber, showed promising results but did not lead to improvements during acute recordings.
Collapse
Affiliation(s)
- Katharina Foremny
- Institute of AudioNeuroTechnology and Department of Experimental Otology, ENT Clinic, Hannover Medical School, 30625 Hannover, Germany; (W.S.K.); (A.B.); (P.B.); (A.K.); (T.D.)
- Correspondence:
| | - Wiebke S. Konerding
- Institute of AudioNeuroTechnology and Department of Experimental Otology, ENT Clinic, Hannover Medical School, 30625 Hannover, Germany; (W.S.K.); (A.B.); (P.B.); (A.K.); (T.D.)
| | - Ailke Behrens
- Institute of AudioNeuroTechnology and Department of Experimental Otology, ENT Clinic, Hannover Medical School, 30625 Hannover, Germany; (W.S.K.); (A.B.); (P.B.); (A.K.); (T.D.)
| | - Peter Baumhoff
- Institute of AudioNeuroTechnology and Department of Experimental Otology, ENT Clinic, Hannover Medical School, 30625 Hannover, Germany; (W.S.K.); (A.B.); (P.B.); (A.K.); (T.D.)
| | - Ulrich P. Froriep
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany;
| | - Andrej Kral
- Institute of AudioNeuroTechnology and Department of Experimental Otology, ENT Clinic, Hannover Medical School, 30625 Hannover, Germany; (W.S.K.); (A.B.); (P.B.); (A.K.); (T.D.)
| | - Theodor Doll
- Institute of AudioNeuroTechnology and Department of Experimental Otology, ENT Clinic, Hannover Medical School, 30625 Hannover, Germany; (W.S.K.); (A.B.); (P.B.); (A.K.); (T.D.)
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany;
| |
Collapse
|
16
|
Yusuf PA, Hubka P, Tillein J, Vinck M, Kral A. Deafness Weakens Interareal Couplings in the Auditory Cortex. Front Neurosci 2021; 14:625721. [PMID: 33551733 PMCID: PMC7858676 DOI: 10.3389/fnins.2020.625721] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 12/30/2020] [Indexed: 12/22/2022] Open
Abstract
The function of the cerebral cortex essentially depends on the ability to form functional assemblies across different cortical areas serving different functions. Here we investigated how developmental hearing experience affects functional and effective interareal connectivity in the auditory cortex in an animal model with years-long and complete auditory deprivation (deafness) from birth, the congenitally deaf cat (CDC). Using intracortical multielectrode arrays, neuronal activity of adult hearing controls and CDCs was registered in the primary auditory cortex and the secondary posterior auditory field (PAF). Ongoing activity as well as responses to acoustic stimulation (in adult hearing controls) and electric stimulation applied via cochlear implants (in adult hearing controls and CDCs) were analyzed. As functional connectivity measures pairwise phase consistency and Granger causality were used. While the number of coupled sites was nearly identical between controls and CDCs, a reduced coupling strength between the primary and the higher order field was found in CDCs under auditory stimulation. Such stimulus-related decoupling was particularly pronounced in the alpha band and in top–down direction. Ongoing connectivity did not show such a decoupling. These findings suggest that developmental experience is essential for functional interareal interactions during sensory processing. The outcomes demonstrate that corticocortical couplings, particularly top-down connectivity, are compromised following congenital sensory deprivation.
Collapse
Affiliation(s)
- Prasandhya Astagiri Yusuf
- Department of Medical Physics/Medical Technology Core Cluster IMERI, Faculty of Medicine, University of Indonesia, Jakarta, Indonesia.,Institute of AudioNeuroTechnology, Hannover Medical School, Hanover, Germany.,Department of Experimental Otology of the ENT Clinics, Hannover Medical School, Hanover, Germany
| | - Peter Hubka
- Institute of AudioNeuroTechnology, Hannover Medical School, Hanover, Germany.,Department of Experimental Otology of the ENT Clinics, Hannover Medical School, Hanover, Germany
| | - Jochen Tillein
- Institute of AudioNeuroTechnology, Hannover Medical School, Hanover, Germany.,Department of Experimental Otology of the ENT Clinics, Hannover Medical School, Hanover, Germany.,Department of Otorhinolaryngology, Goethe University, Frankfurt am Main, Germany.,MedEL Company, Innsbruck, Austria
| | - Martin Vinck
- Ernst Strüngmann Institut for Neuroscience in Cooperation with Max Planck Society, Frankfurt, Germany.,Donders Centre for Neuroscience, Radboud University, Department of Neuroinformatics, Nijmegen, Netherlands
| | - Andrej Kral
- Institute of AudioNeuroTechnology, Hannover Medical School, Hanover, Germany.,Department of Experimental Otology of the ENT Clinics, Hannover Medical School, Hanover, Germany.,Department of Biomedical Sciences, School of Medicine and Health Sciences, Macquarie University, Sydney, NSW, Australia
| |
Collapse
|
17
|
Quass GL, Baumhoff P, Gnansia D, Stahl P, Kral A. Level coding by phase duration and asymmetric pulse shape reduce channel interactions in cochlear implants. Hear Res 2020; 396:108070. [PMID: 32950954 DOI: 10.1016/j.heares.2020.108070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 08/21/2020] [Accepted: 08/31/2020] [Indexed: 10/23/2022]
Abstract
Conventional loudness coding with CIs by pulse current amplitude has a disadvantage: Increasing the stimulation current increases the spread of excitation in the auditory nerve, resulting in stronger channel interactions at high stimulation levels. These limit the number of effective information channels that a CI user can perceive. Stimulus intensity information (loudness) can alternatively be transmitted via pulse phase duration. We hypothesized that loudness coding by phase duration avoids the increase in the spread of the electric field and thus leads to less channel interactions at high stimulation levels. To avoid polarity effects, we combined this coding with pseudomonophasic stimuli. To test whether this affects the spread of excitation, 16 acutely deafened guinea pigs were implanted with CIs and neural activity from the inferior colliculus was recorded while stimulating with either biphasic, amplitude-coded pulses, or pseudomonophasic, duration- or amplitude-coded pulses. Pseudomonophasic stimuli combined with phase duration loudness coding reduced the lowest response thresholds and the spread of excitation. We investigated the channel interactions at suprathreshold levels by computing the phase-locking to a pulse train in the presence of an interacting pulse train on a different electrode on the CI. Pseudomonophasic pulses coupled with phase duration loudness coding reduced the interference by 4-5% compared to biphasic pulses, depending on the place of stimulation. This effect of pseudomonophasic stimuli was achieved with amplitude coding only in the basal cochlea, indicating a distance- or volume dependent effect. Our results show that pseudomonophasic, phase-duration-coded stimuli slightly reduce channel interactions, suggesting a potential benefit for speech understanding in humans.
Collapse
Affiliation(s)
- Gunnar Lennart Quass
- Institute for AudioNeuroTechnology (VIANNA), ENT Clinics, Hannover Medical School, 30625 Hannover, Germany; Cluster of Excellence "Hearing4All" (EXC 2177).
| | - Peter Baumhoff
- Institute for AudioNeuroTechnology (VIANNA), ENT Clinics, Hannover Medical School, 30625 Hannover, Germany
| | | | | | - Andrej Kral
- Institute for AudioNeuroTechnology (VIANNA), ENT Clinics, Hannover Medical School, 30625 Hannover, Germany; Cluster of Excellence "Hearing4All" (EXC 2177)
| |
Collapse
|
18
|
Andrade JSCD, Baumhoff P, Cruz OLM, Lenarz T, Kral A. Cochlear implantation in an animal model documents cochlear damage at the tip of the implant. Braz J Otorhinolaryngol 2020; 88:546-555. [PMID: 33039317 PMCID: PMC9422412 DOI: 10.1016/j.bjorl.2020.07.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 07/13/2020] [Accepted: 07/30/2020] [Indexed: 11/28/2022] Open
Abstract
INTRODUCTION Electrocochleography has recently emerged as a diagnostic tool in cochlear implant surgery, purposing hearing preservation and optimal electrode positioning. OBJECTIVE In this experimental study, extra-cochlear potentials were obtained during cochlear implant surgery in guinea pigs. The aim was to determine electrophysiological changes indicating cochlear trauma after cochleostomy and after electrode implantation in different insertion depths. METHODS Normal-hearing guinea pigs (n = 14) were implanted uni- or bilaterally with a multichannel electrode. The extra-cochlear cochlear nerve action potentials were obtained in response to acoustic stimuli at specific frequencies before and after cochleostomy, and after introduction of the electrode bundle. After the electrophysiological experiments, the guinea pigs were euthanized and microtomography was performed, in order to determine the position of the electrode and to calculate of the depth of insertion. Based on the changes of amplitude and thresholds in relation to the stimulus frequency, the electrophysiological data and the position obtained by the microtomography reconstruction were compared. RESULTS Cochleostomy promoted a small electrophysiological impact, while electrode insertion caused changes in the amplitude of extra-cochlear electrophysiological potentials over a wide range of frequencies, especially in the deepest insertions. There was, however, preservation of the electrical response to low frequency stimuli in most cases, indicating a limited auditory impact in the intraoperative evaluation. The mean insertion depth of the apical electrodes was 5339.56 μm (±306.45 - 6 inserted contacts) and 4447.75 μm (±290.23 - 5 inserted contacts). CONCLUSIONS The main electrophysiological changes observed during surgical procedures occurred during implantation of the electrode, especially the deepest insertions, whereas the cochleostomy disturbed the potentials to a lesser extent. While hearing loss was often observed apical to the cochlear implant, it was possible to preserve low frequencies after insertion.
Collapse
Affiliation(s)
- José Santos Cruz de Andrade
- Universidade Federal de São Paulo (UNIFESP), Departamento de Otorrinolaringologia e Cirurgia de Cabeça e Pescoço, São Paulo, SP, Brazil; Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (Fundação CAPES), Brasília, DF, Brazil; Institute of Audioneurotechnology (VIANNA) & Dept. of Experimental Otology, Department of Otolaryngology, Medical University Hannover, Hannover, Germany.
| | - Peter Baumhoff
- Institute of Audioneurotechnology (VIANNA) & Dept. of Experimental Otology, Department of Otolaryngology, Medical University Hannover, Hannover, Germany; Cluster of Excellence "Hearing4all", Hannover, Germany
| | - Oswaldo Laércio Mendonça Cruz
- Universidade Federal de São Paulo (UNIFESP), Departamento de Otorrinolaringologia e Cirurgia de Cabeça e Pescoço, São Paulo, SP, Brazil; Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (Fundação CAPES), Brasília, DF, Brazil
| | - Thomas Lenarz
- Institute of Audioneurotechnology (VIANNA) & Dept. of Experimental Otology, Department of Otolaryngology, Medical University Hannover, Hannover, Germany; Cluster of Excellence "Hearing4all", Hannover, Germany
| | - Andrej Kral
- Institute of Audioneurotechnology (VIANNA) & Dept. of Experimental Otology, Department of Otolaryngology, Medical University Hannover, Hannover, Germany; Cluster of Excellence "Hearing4all", Hannover, Germany
| |
Collapse
|
19
|
Kipping D, Krüger B, Nogueira W. The role of electroneural versus electrophonic stimulation on psychoacoustic electric-acoustic masking in cochlear implant users with residual hearing. Hear Res 2020; 395:108036. [PMID: 32736202 DOI: 10.1016/j.heares.2020.108036] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 06/18/2020] [Accepted: 06/28/2020] [Indexed: 11/26/2022]
Abstract
Cochlear implant (CI) candidates with residual low-frequency hearing are nowadays often implanted with CI electrode arrays that allow preserving their acoustic hearing in the implanted ear. These subjects receiving combined electric-acoustic stimulation (EAS) show enhanced speech perception scores when compared to traditional CI users without acoustic component. However, these benefits are limited by interaction effects such as masking between electric and acoustic stimulation. This study evaluates ipsilateral electric-acoustic masking in a psychophysical experiment conducted in 5 EAS subjects. The elevation of acoustic pure tone thresholds through simultaneous presentation of electric pulse trains and vice versa is measured for different acoustic frequencies and different settings of the electric stimuli. Electric-acoustic interaction could originate either from electroneural stimulation of auditory nerve fibers or from electrophonic stimulation of hair cells. The two fundamental goals of this study are to investigate the effects of stimulation rate and phase duration of the electric stimulus on electric-acoustic masking and to investigate the origin of electric-acoustic masking by assessing the contributions of electroneural versus electrophonic stimulation. The amount of electric-acoustic masking in the present study was independent of pulse rate and phase duration of the electric stimuli. Moreover, the results demonstrate that electric-acoustic masking depends on the spatial distance between the locations of electric or acoustic excitation in the cochlea, but not on the spectral content of the electric stimulus. We thereby conclude that psychoacoustic electric-acoustic masking in EAS users is dominated by electroneural-acoustic interaction, whereas the contribution of electrophonic stimulation is negligible.
Collapse
Affiliation(s)
- Daniel Kipping
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany; Cluster of Excellence Hearing4all, Germany.
| | - Benjamin Krüger
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany; Cluster of Excellence Hearing4all, Germany.
| | - Waldo Nogueira
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany; Cluster of Excellence Hearing4all, Germany.
| |
Collapse
|
20
|
Postoperative Intracochlear Electrocochleography in Pediatric Cochlear Implant Recipients: Association to Audiometric Thresholds and Auditory Performance. Ear Hear 2020; 41:1135-1143. [DOI: 10.1097/aud.0000000000000833] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
21
|
Konerding W, Arenberg JG, Kral A, Baumhoff P. Late electrically-evoked compound action potentials as markers for acute micro-lesions of spiral ganglion neurons. Hear Res 2020; 413:108057. [PMID: 32883545 DOI: 10.1016/j.heares.2020.108057] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 07/13/2020] [Accepted: 08/11/2020] [Indexed: 12/20/2022]
Abstract
Cochlear implants (CIs) are the treatment of choice for profoundly hearing impaired people. It has been proposed that speech perception in CI users is influenced by the neural health (deafferentation, demyelination and degeneration) of the cochlea, which may be heterogeneous along an individual cochlea. Several options have been put forward to account for these local differences in neural health when fitting the speech processor settings, however with mixed results. The interpretation of the results is hampered by the fact that reliable markers of locally restricted changes in spiral ganglion neuron (SGN) health are lacking. The aim of the study was (i) to establish mechanical micro-lesions in the guinea pig as a model of heterogeneous SGN deafferentation and degeneration and (ii) to assess potential electrophysiological markers that can also be used in human subjects. First, we defined the extent of micro-lesions in normal hearing animals using acoustically-evoked compound action potentials (aCAPs); second, we measured electrically-evoked CAPs (eCAPs) before and after focal lesioning in neomycin-deafened and implanted animals. Therefore, we inserted guinea pig adjusted 6-contact CIs through a cochleostomy in the scala tympani. The eCAP was recorded from a ball electrode at the round window niche in response to monopolar or bipolar, 50 µs/phase biphasic pulses of alternating anodic- and cathodic-leading polarity. To exclude the large electrical artifact from the analysis, we focused on the late eCAP component. We systematically isolated the eCAP parameter that showed local pre- versus post-lesion changes and lesion-target specificity. Histological evaluation of the cleared cochleae revealed focal damage of an average size of 0.0036 mm3 with an apical-basal span of maximal 440 µm. We found that the threshold of the late N2P2 eCAP component was significantly elevated after lesioning when stimulating at basal (near the lesion), but not apical (distant to the lesion) CI contacts. To circumvent the potentially conflicting influence of the apical-basal gradient in eCAP thresholds, we used the polarity effect (PE=cathodic-anodic) as a relative measure. During monopolar stimulation, but not bipolar stimulation, the PE was sensitive to the lesion target and showed significantly better cathodic than anodic thresholds after soma lesions. We conclude that the difference in N2P2 thresholds in response to cathodic versus anodic-leading monopolar stimulation corresponds to the presence of SGN soma damage, and may therefore be a marker for SGN loss. We consider this electrophysiological estimate of local neural health a potentially relevant tool for human applications because of the temporal separation from the stimulation artifact and possible implementation into common eCAP measurements.
Collapse
Affiliation(s)
- Wiebke Konerding
- Department of Experimental Otology, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany.
| | - Julie G Arenberg
- Massachusetts Eye and Ear Infirmary, Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA.
| | - Andrej Kral
- Department of Experimental Otology, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany; Cluster of Excellence "Hearing4all", Germany.
| | - Peter Baumhoff
- Department of Experimental Otology, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany.
| |
Collapse
|
22
|
Krüger B, Büchner A, Lenarz T, Nogueira W. Electric-acoustic interaction measurements in cochlear-implant users with ipsilateral residual hearing using electrocochleography. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:350. [PMID: 32006967 DOI: 10.1121/10.0000577] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Accepted: 12/19/2019] [Indexed: 06/10/2023]
Abstract
Cochlear implantation is increasingly being used as a hearing-loss treatment for patients with residual hearing in the low acoustic frequencies. These patients obtain combined electric-acoustic stimulation (EAS). Substantial residual hearing and relatively long electrode arrays can lead to interactions between the electric and acoustic stimulation. This work investigated EAS interaction through psychophysical and electrophysiological measures. Moreover, cone-beam computed-tomography data was used to characterize the interaction along spatial cochlear locations. Psychophysical EAS interaction was estimated based on the threshold of audibility of an acoustic probe stimulus in the presence of a simultaneously presented electric masker stimulus. Intracochlear electrocochleography was used to estimate electrophysiological EAS interaction via the telemetry capability of the cochlear implant. EAS interaction was observed using psychophysical and electrophysiological measurements. While psychoacoustic EAS interaction was most pronounced close to the electrical stimulation site, electrophysiological EAS interaction was observed over a wider range of spatial cochlear locations. Psychophysical EAS interaction was significantly larger than electrophysiological EAS interaction for acoustic probes close to the electrode position.
Collapse
Affiliation(s)
- Benjamin Krüger
- Department of Otolaryngology, Hannover Medical School, Cluster of Excellence Hearing4all, Carl-Neuberg-Straße 1, 30625 Hannover, Germany
| | - Andreas Büchner
- Department of Otolaryngology, Hannover Medical School, Cluster of Excellence Hearing4all, Carl-Neuberg-Straße 1, 30625 Hannover, Germany
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Cluster of Excellence Hearing4all, Carl-Neuberg-Straße 1, 30625 Hannover, Germany
| | - Waldo Nogueira
- Department of Otolaryngology, Hannover Medical School, Cluster of Excellence Hearing4all, Carl-Neuberg-Straße 1, 30625 Hannover, Germany
| |
Collapse
|
23
|
Brown AD, Anbuhl KL, Gilmer JI, Tollin DJ. Between-ear sound frequency disparity modulates a brain stem biomarker of binaural hearing. J Neurophysiol 2019; 122:1110-1122. [PMID: 31314646 PMCID: PMC6766741 DOI: 10.1152/jn.00057.2019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 07/02/2019] [Accepted: 07/03/2019] [Indexed: 11/22/2022] Open
Abstract
The auditory brain stem response (ABR) is an evoked potential that indexes a cascade of neural events elicited by sound. In the present study we evaluated the influence of sound frequency on a derived component of the ABR known as the binaural interaction component (BIC). Specifically, we evaluated the effect of acoustic interaural (between-ear) frequency mismatch on BIC amplitude. Goals were to 1) increase basic understanding of sound features that influence this long-studied auditory potential and 2) gain insight about the persistence of the BIC with interaural electrode mismatch in human users of bilateral cochlear implants, presently a limitation on the prospective utility of the BIC in audiological settings. Data were collected in an animal model that is audiometrically similar to humans, the chinchilla (Chinchilla lanigera; 6 females). Frequency disparities and amplitudes of acoustic stimuli were varied over broad ranges, and associated variation of BIC amplitude was quantified. Subsequently, responses were simulated with the use of established models of the brain stem pathway thought to underlie the BIC. Collectively, the data demonstrate that at high sound intensities (≥85 dB SPL), the acoustically elicited BIC persisted with interaurally disparate stimulation (click frequencies ≥1.5 octaves apart). However, sharper tuning emerged at moderate sound intensities (65 dB SPL), with the largest BIC occurring for stimulus frequencies within ~0.8 octaves, equivalent to ±1 mm in cochlear place. Such responses were consistent with simulated responses of the presumed brain stem generator of the BIC, the lateral superior olive. The data suggest that leveraging focused electrical stimulation strategies could improve BIC-based bilateral cochlear implant fitting outcomes.NEW & NOTEWORTHY Traditional hearing tests evaluate each ear independently. Diagnosis and treatment of binaural hearing dysfunction remains a basic challenge for hearing clinicians. We demonstrate in an animal model that the prospective utility of a noninvasive electrophysiological signature of binaural function, the binaural interaction component (BIC), depends strongly on the intensity of auditory stimulation. Data suggest that more informative BIC measurements could be obtained with clinical protocols leveraging stimuli restricted in effective bandwidth.
Collapse
Affiliation(s)
- Andrew D Brown
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington
| | - Kelsey L Anbuhl
- Center for Neural Science, New York University, New York, New York
| | - Jesse I Gilmer
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado
- Neuroscience Training Program, University of Colorado School of Medicine, Aurora, Colorado
| | - Daniel J Tollin
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado
- Neuroscience Training Program, University of Colorado School of Medicine, Aurora, Colorado
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado
| |
Collapse
|
24
|
Gordon K, Kral A. Animal and human studies on developmental monaural hearing loss. Hear Res 2019; 380:60-74. [DOI: 10.1016/j.heares.2019.05.011] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Revised: 05/29/2019] [Accepted: 05/30/2019] [Indexed: 11/26/2022]
|
25
|
Nassiri AM, Yawn RJ, Gifford RH, Haynes DS, Roberts JB, Gilbane MS, Murfee J, Bennett ML. Intraoperative Electrically Evoked Compound Action Potential (ECAP) Measurements in Traditional and Hearing Preservation Cochlear Implantation. J Am Acad Audiol 2019; 30:918-926. [PMID: 31274070 DOI: 10.3766/jaaa.18052] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND In current practice, the status of residual low-frequency acoustic hearing in hearing preservation cochlear implantation (CI) is unknown until activation two to three weeks postoperatively. The intraoperatively measured electrically evoked compound action potential (ECAP), a synchronous response from electrically stimulated auditory nerve fibers, is one of the first markers of auditory nerve function after cochlear implant surgery and such may provide information regarding the status of residual low-frequency acoustic hearing. PURPOSE This study aimed to evaluate the relationship between intraoperative ECAP at the time of CI and presence of preoperative and postoperative low-frequency acoustic hearing. RESEARCH DESIGN A retrospective case review. STUDY SAMPLE Two hundred seventeen adult ears receiving CI (42 Advanced Bionics, 82 Cochlear, and 93 MED-EL implants). INTERVENTIONS Intraoperative ECAP and CI. DATA COLLECTION AND ANALYSIS ECAP measurements were obtained intraoperatively, whereas residual hearing data were obtained from postoperative CI activation audiogram. A linear mixed model test revealed no interaction effects for the following variables: manufacturer, electrode location (basal, middle, and apical), preoperative low-frequency pure-tone average (LFPTA), and postoperative LFPTA. The postoperative residual low-frequency hearing status was defined as preservation of unaided air conduction thresholds ≤90 dB at 250 Hz. Electrode location and hearing preservation data were analyzed individually for both the ECAP threshold and ECAP maximum amplitude using multiple t-tests, without assuming a consistent standard deviation between the groups, and with alpha correction. RESULTS The maximum amplitude, in microvolts, was significantly higher throughout apical and middle regions of the cochlea in patients who had preserved low-frequency acoustic hearing as compared with those who did not have preserved hearing (p = 0.0001 and p = 0.0088, respectively). ECAP threshold, in microamperes, was significantly lower throughout the apical region of the cochlea in patients with preserved low-frequency acoustic hearing as compared with those without preserved hearing (p = 0.0099). Basal electrode maximum amplitudes and middle and basal electrode thresholds were not significantly correlated with postoperative low-frequency hearing. CONCLUSIONS Apical and middle electrode maximum amplitudes and apical electrode thresholds detected through intraoperative ECAP measurements are significantly correlated with preservation of low-frequency acoustic hearing. This association may represent a potential immediate feedback mechanism for postoperative outcomes that can be applied to all CIs.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Jack Murfee
- Vanderbilt University Medical Center, Nashville, TN
| | | |
Collapse
|
26
|
Intracochlear near infrared stimulation: Feasibility of optoacoustic stimulation in vivo. Hear Res 2018; 371:40-52. [PMID: 30458383 DOI: 10.1016/j.heares.2018.11.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Revised: 10/04/2018] [Accepted: 11/08/2018] [Indexed: 01/12/2023]
Abstract
Intracochlear optical stimulation has been suggested as an alternative approach to hearing prosthetics in recent years. This study investigated the properties of a near infrared laser (NIR) induced optoacoustic effect. Pressure recordings were performed at the external meatus of anaesthetized guinea pigs during intracochlear NIR stimulation. The sound pressure and power spectra were determined. The results were compared to multi unit responses in the inferior colliculus (IC). Additionally, the responses to NIR stimulation were compared to IC responses induced by intracochlear electric stimulation at the same cochlear position to investigate a potentially confounding contribution of direct neural NIR stimulation. The power spectra of the sound recorded at the external meatus (n = 7) had most power at frequencies below 10 kHz and showed little variation for different stimulation sites. The mean spike rates of IC units responding to intracochlear NIR stimulation (n = 222) of 17 animals were significantly correlated with the power of the externally recorded signal at frequencies corresponding to the best frequencies of the IC units. The response strength as well as the sound pressure at the external meatus depended on the pulse peak power of the optical stimulus. The sound pressure recorded at the external meatus reached levels above 70 dB SPL peak equivalent. In hearing animals a cochlear activation apical to the location of the fiber was found. The absence of any NIR responses after pharmacologically deafening and the comparison to electric stimulation at the NIR stimulation site revealed no indication of a confounding direct neural NIR stimulation. Intracochlear optoacoustic stimulation might become useful in combined electro-acoustic stimulation devices in the future.
Collapse
|
27
|
Neural Processing of Acoustic and Electric Interaural Time Differences in Normal-Hearing Gerbils. J Neurosci 2018; 38:6949-6966. [PMID: 29959238 DOI: 10.1523/jneurosci.3328-17.2018] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 06/04/2018] [Accepted: 06/04/2018] [Indexed: 12/18/2022] Open
Abstract
Bilateral cochlear implants (CIs) provide benefits for speech perception in noise and directional hearing, but users typically show poor sensitivity to interaural time differences (ITDs). Possible explanations for this deficit are deafness-induced degradations in neural ITD sensitivity, between-ear mismatches in electrode positions or activation sites, or differences in binaural brain circuits activated by electric versus acoustic stimulation. To identify potential limitations of electric ITD coding in the normal-hearing system, responses of single neurons in the dorsal nucleus of the lateral lemniscus and in the inferior colliculus to ITDs of electric (biphasic pulses) and acoustic (noise, clicks, chirps, and tones) stimuli were recorded in normal-hearing gerbils of either sex. To maintain acoustic sensitivity, electric stimuli were delivered to the round window. ITD tuning metrics (e.g., best ITD) and ITD discrimination thresholds for electric versus transient acoustic stimuli (clicks, chirps) obtained from the same neurons were not significantly correlated. Across populations of neurons with similar characteristic frequencies, however, ITD tuning metrics and ITD discrimination thresholds were similar for electric and acoustic stimuli and largely independent of the spectrotemporal properties of the acoustic stimuli when measured in the central range of ITDs. The similarity of acoustic and electric ITD coding on the population level in animals with normal hearing experience suggests that poorer ITD sensitivity in bilateral CI users compared with normal-hearing listeners is likely due to deprivation-induced changes in neural ITD coding rather than to differences in the binaural brain circuits involved in the processing of electric and acoustic ITDs.SIGNIFICANCE STATEMENT Small differences in the arrival time of sound at the two ears (interaural time differences, ITDs) provide important cues for speech understanding in noise and directional hearing. Deaf subjects with bilateral cochlear implants obtain only little benefit from ITDs. It is unclear whether these limitations are due to between-ear mismatches in activation sites, differences in binaural brain circuits activated by electric versus acoustic stimulation, or deafness-induced degradations in neural ITD processing. This study is the first to directly compare electric and acoustic ITD coding in neurons of known characteristic frequencies. In animals with normal hearing, populations of auditory brainstem and midbrain neurons demonstrate general similarities in electric and acoustic ITD coding, suggesting similar underlying central auditory processing mechanisms.
Collapse
|
28
|
Abstract
OBJECTIVE Electrical stimulation is normally performed on ears that have no hearing function, i.e., lack functional hair cells. The properties of electrically-evoked responses in these cochleae were investigated in several previous studies. Recent clinical developments have introduced cochlear implantation (CI) in residually-hearing ears to improve speech understanding in noise. The present study documents the known physiological differences between electrical stimulation of hair cells and of spiral ganglion cells, respectively, and reviews the mechanisms of combined electric and acoustic stimulation in the hearing ears. DATA SOURCES Literature review from 1971 to 2016. CONCLUSIONS Compared with pure electrical stimulation the combined electroacoustic stimulation provides additional low-frequency information and expands the dynamic range of the input. Physiological studies document a weaker synchronization of the evoked activity in electrically stimulated hearing ears compared with deaf ears that reduces the hypersynchronization of electrically-evoked activity. The findings suggest the possibility of balancing the information provided by acoustic and electric input using stimulus intensity. Absence of distorting acoustic-electric interactions allows exploiting these clinical benefits of electroacoustic stimulation.
Collapse
|
29
|
Palmer JC, Lord MS, Pinyon JL, Wise AK, Lovell NH, Carter PM, Enke YL, Housley GD, Green RA. Comparing perilymph proteomes across species. Laryngoscope 2017; 128:E47-E52. [DOI: 10.1002/lary.26885] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 08/02/2017] [Accepted: 08/07/2017] [Indexed: 11/08/2022]
Affiliation(s)
- Jonathan C. Palmer
- Graduate School of Biomedical EngineeringUniversity of New South Wales SydneySydneyNew South WalesAustralia
| | - Megan S. Lord
- Graduate School of Biomedical EngineeringUniversity of New South Wales SydneySydneyNew South WalesAustralia
| | - Jeremy L. Pinyon
- Translational Neuroscience Facility and Department of Physiology, School of Medical SciencesUniversity of New South Wales SydneySydneyNew South WalesAustralia
| | | | - Nigel H. Lovell
- Graduate School of Biomedical EngineeringUniversity of New South Wales SydneySydneyNew South WalesAustralia
| | - Paul M. Carter
- Cochlear LtdMacquarie UniversitySydneyNew South WalesAustralia
| | - Ya Lang Enke
- Cochlear LtdMacquarie UniversitySydneyNew South WalesAustralia
| | - Gary D. Housley
- Translational Neuroscience Facility and Department of Physiology, School of Medical SciencesUniversity of New South Wales SydneySydneyNew South WalesAustralia
| | - Rylie A. Green
- Graduate School of Biomedical EngineeringUniversity of New South Wales SydneySydneyNew South WalesAustralia
- Department of BioengineeringImperial College LondonLondonUnited Kingdom
| |
Collapse
|
30
|
Selective Neuronal Activation by Cochlear Implant Stimulation in Auditory Cortex of Awake Primate. J Neurosci 2017; 36:12468-12484. [PMID: 27927962 DOI: 10.1523/jneurosci.1699-16.2016] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Revised: 10/05/2016] [Accepted: 10/10/2016] [Indexed: 11/21/2022] Open
Abstract
Despite the success of cochlear implants (CIs) in human populations, most users perform poorly in noisy environments and music and tonal language perception. How CI devices engage the brain at the single neuron level has remained largely unknown, in particular in the primate brain. By comparing neuronal responses with acoustic and CI stimulation in marmoset monkeys unilaterally implanted with a CI electrode array, we discovered that CI stimulation was surprisingly ineffective at activating many neurons in auditory cortex, particularly in the hemisphere ipsilateral to the CI. Further analyses revealed that the CI-nonresponsive neurons were narrowly tuned to frequency and sound level when probed with acoustic stimuli; such neurons likely play a role in perceptual behaviors requiring fine frequency and level discrimination, tasks that CI users find especially challenging. These findings suggest potential deficits in central auditory processing of CI stimulation and provide important insights into factors responsible for poor CI user performance in a wide range of perceptual tasks. SIGNIFICANCE STATEMENT The cochlear implant (CI) is the most successful neural prosthetic device to date and has restored hearing in hundreds of thousands of deaf individuals worldwide. However, despite its huge successes, CI users still face many perceptual limitations, and the brain mechanisms involved in hearing through CI devices remain poorly understood. By directly comparing single-neuron responses to acoustic and CI stimulation in auditory cortex of awake marmoset monkeys, we discovered that neurons unresponsive to CI stimulation were sharply tuned to frequency and sound level. Our results point out a major deficit in central auditory processing of CI stimulation and provide important insights into mechanisms underlying the poor CI user performance in a wide range of perceptual tasks.
Collapse
|
31
|
Krüger B, Büchner A, Nogueira W. Simultaneous masking between electric and acoustic stimulation in cochlear implant users with residual low-frequency hearing. Hear Res 2017; 353:185-196. [PMID: 28688755 DOI: 10.1016/j.heares.2017.06.014] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Revised: 06/27/2017] [Accepted: 06/28/2017] [Indexed: 11/18/2022]
Abstract
Ipsilateral electric-acoustic stimulation (EAS) is becoming increasingly important in cochlear implant (CI) treatment. Improvements in electrode designs and surgical techniques have contributed to improved hearing preservation during implantation. Consequently, CI implantation criteria have been expanded toward people with significant residual low-frequency hearing, who may benefit from the combined use of both the electric and acoustic stimulation in the same ear. However, only few studies have investigated the mutual interaction between electric and acoustic stimulation modalities. This work characterizes the interaction between both stimulation modalities using psychophysical masking experiments and cone beam computer tomography (CBCT). Two psychophysical experiments for electric and acoustic masking were performed to measure the hearing threshold elevation of a probe stimulus in the presence of a masker stimulus. For electric masking, the probe stimulus was an acoustic tone while the masker stimulus was an electric pulse train. For acoustic masking, the probe stimulus was an electric pulse train and the masker stimulus was an acoustic tone. Five EAS users, implanted with a CI and ipsilateral residual low-frequency hearing, participated in the study. Masking was determined at different electrodes and different acoustic frequencies. CBCT scans were used to determine the individual place-pitch frequencies of the intracochlear electrode contacts by using the Stakhovskaya place-to-frequency transformation. This allows the characterization of masking as a function of the difference between electric and acoustic stimulation sites, which we term the electric-acoustic frequency difference (EAFD). The results demonstrate a significant elevation of detection thresholds for both experiments. In electric masking, acoustic-tone thresholds increased exponentially with decreasing EAFD. In contrast, for the acoustic masking experiment, threshold elevations were present regardless of the tested EAFDs. Based on the present findings, we conclude that there is an asymmetry between the electric and the acoustic masker modalities. These observations have implications for the design and fitting of EAS sound-coding strategies.
Collapse
Affiliation(s)
- Benjamin Krüger
- Department of Otolaryngology, Hannover Medical School, Cluster of Excellence Hearing4all, Hannover, Germany.
| | - Andreas Büchner
- Department of Otolaryngology, Hannover Medical School, Cluster of Excellence Hearing4all, Hannover, Germany.
| | - Waldo Nogueira
- Department of Otolaryngology, Hannover Medical School, Cluster of Excellence Hearing4all, Hannover, Germany.
| |
Collapse
|
32
|
A Test of the Stereausis Hypothesis for Sound Localization in Mammals. J Neurosci 2017; 37:7278-7289. [PMID: 28659280 DOI: 10.1523/jneurosci.0233-17.2017] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Revised: 05/20/2017] [Accepted: 05/25/2017] [Indexed: 11/21/2022] Open
Abstract
The relative arrival times of sounds at both ears constitute an important cue for localization of low-frequency sounds in the horizontal plane. The binaural neurons of the medial superior olive (MSO) act as coincidence detectors that fire when inputs from both ears arrive near simultaneously. Each principal neuron in the MSO is tuned to its own best interaural time difference (ITD), indicating the presence of an internal delay, a difference in the travel times from either ear to the MSO. According to the stereausis hypothesis, differences in wave propagation along the cochlea could provide the delays necessary for coincidence detection if the ipsilateral and contralateral inputs originated from different cochlear positions, with different frequency tuning. We therefore investigated the relation between interaural mismatches in frequency tuning and ITD tuning during in vivo loose-patch (juxtacellular) recordings from principal neurons of the MSO of anesthetized female gerbils. Cochlear delays can be bypassed by directly stimulating the auditory nerve; in agreement with the stereausis hypothesis, tuning for timing differences during bilateral electrical stimulation of the round windows differed markedly from ITD tuning in the same cells. Moreover, some neurons showed a frequency tuning mismatch that was sufficiently large to have a potential impact on ITD tuning. However, we did not find a correlation between frequency tuning mismatches and best ITDs. Our data thus suggest that axonal delays dominate ITD tuning.SIGNIFICANCE STATEMENT Neurons in the medial superior olive (MSO) play a unique role in sound localization because of their ability to compare the relative arrival time of low-frequency sounds at both ears. They fire maximally when the difference in sound arrival time exactly compensates for the internal delay: the difference in travel time from either ear to the MSO neuron. We tested whether differences in cochlear delay systematically contribute to the total travel time by comparing for individual MSO neurons the best difference in arrival times, as predicted from the frequency tuning for either ear, and the actual best difference. No systematic relation was observed, emphasizing the dominant contribution of axonal delays to the internal delay.
Collapse
|
33
|
Palmer JC, Lord MS, Pinyon JL, Wise AK, Lovell NH, Carter PM, Enke YL, Housley GD, Green RA. Understanding the cochlear implant environment by mapping perilymph proteomes from different species. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:5237-5240. [PMID: 28269445 DOI: 10.1109/embc.2016.7591908] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Cochlear implants operate within a bony channel of the cochlea, bathed in a fluid known as the perilymph. The perilymph is a complex fluid containing ions and proteins, which are known to actively interact with metallic electrodes. To improve our understanding of how cochlear implant performance varies in preclinical in vivo studies in comparison to human trials and patient outcomes, the protein composition (or perilymph proteome) is needed. Samples of perilymph were gathered from feline and guinea pig subjects and analyzed using liquid chromatography with tandem mass spectrometry (LC-MS/MS) to produce proteomes and compare against the recently published human proteome. Over 64% of the proteins in the guinea pig proteome were found to be common to the human proteome. The proportions of apolipoproteins, enzymes and immunoglobulins showed little variation between the two proteomes, with other classes showing similarity. This establishes a good basis for comparison of results. The results for the feline profile showed less similarity with the human proteome and would not provide a quality comparison. This work highlights the suitability of the guinea pig to model the biological environment of the human cochlear and the need to carefully select models of the biological environment of a cochlear implant to more adequately translate in vitro and in vivo studies to the clinic.
Collapse
|
34
|
Vassanelli S, Mahmud M. Trends and Challenges in Neuroengineering: Toward "Intelligent" Neuroprostheses through Brain-"Brain Inspired Systems" Communication. Front Neurosci 2016; 10:438. [PMID: 27721741 PMCID: PMC5034009 DOI: 10.3389/fnins.2016.00438] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Accepted: 09/09/2016] [Indexed: 11/30/2022] Open
Abstract
Future technologies aiming at restoring and enhancing organs function will intimately rely on near-physiological and energy-efficient communication between living and artificial biomimetic systems. Interfacing brain-inspired devices with the real brain is at the forefront of such emerging field, with the term "neurobiohybrids" indicating all those systems where such interaction is established. We argue that achieving a "high-level" communication and functional synergy between natural and artificial neuronal networks in vivo, will allow the development of a heterogeneous world of neurobiohybrids, which will include "living robots" but will also embrace "intelligent" neuroprostheses for augmentation of brain function. The societal and economical impact of intelligent neuroprostheses is likely to be potentially strong, as they will offer novel therapeutic perspectives for a number of diseases, and going beyond classical pharmaceutical schemes. However, they will unavoidably raise fundamental ethical questions on the intermingling between man and machine and more specifically, on how deeply it should be allowed that brain processing is affected by implanted "intelligent" artificial systems. Following this perspective, we provide the reader with insights on ongoing developments and trends in the field of neurobiohybrids. We address the topic also from a "community building" perspective, showing through a quantitative bibliographic analysis, how scientists working on the engineering of brain-inspired devices and brain-machine interfaces are increasing their interactions. We foresee that such trend preludes to a formidable technological and scientific revolution in brain-machine communication and to the opening of new avenues for restoring or even augmenting brain function for therapeutic purposes.
Collapse
Affiliation(s)
- Stefano Vassanelli
- NeuroChip Laboratory, Department of Biomedical Sciences, University of PadovaPadova, Italy
| | | |
Collapse
|
35
|
George SS, Shivdasani MN, Fallon JB. Effect of current focusing on the sensitivity of inferior colliculus neurons to amplitude-modulated stimulation. J Neurophysiol 2016; 116:1104-16. [PMID: 27306672 DOI: 10.1152/jn.00126.2016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Accepted: 06/15/2016] [Indexed: 11/22/2022] Open
Abstract
In multichannel cochlear implants (CIs), current is delivered to specific electrodes along the cochlea in the form of amplitude-modulated pulse trains, to convey temporal and spectral cues. Our previous studies have shown that focused multipolar (FMP) and tripolar (TP) stimulation produce more restricted neural activation and reduced channel interactions in the inferior colliculus (IC) compared with traditional monopolar (MP) stimulation, suggesting that focusing of stimulation could produce better transmission of spectral information. The present study explored the capability of IC neurons to detect modulated CI stimulation with FMP and TP stimulation compared with MP stimulation. The study examined multiunit responses of IC neurons in acutely deafened guinea pigs by systematically varying the stimulation configuration, modulation depth, and stimulation level. Stimuli were sinusoidal amplitude-modulated pulse trains (carrier rate of 120 pulses/s). Modulation sensitivity was quantified by measuring modulation detection thresholds (MDTs), defined as the lowest modulation depth required to differentiate the response of a modulated stimulus from an unmodulated one. Whereas MP stimulation showed significantly lower MDTs than FMP and TP stimulation (P values <0.05) at stimulation ≤2 dB above threshold, all stimulation configurations were found to have similar modulation sensitivities at 4 dB above threshold. There was no difference found in modulation sensitivity between FMP and TP stimulation. The present study demonstrates that current focusing techniques such as FMP and TP can adequately convey amplitude modulation and are comparable to MP stimulation, especially at higher stimulation levels, although there may be some trade-off between spectral and temporal fidelity with current focusing stimulation.
Collapse
Affiliation(s)
- Shefin S George
- The Bionics Institute, East Melbourne, Australia; and Department of Medical Bionics, University of Melbourne, Melbourne, Australia
| | - Mohit N Shivdasani
- The Bionics Institute, East Melbourne, Australia; and Department of Medical Bionics, University of Melbourne, Melbourne, Australia
| | - James B Fallon
- The Bionics Institute, East Melbourne, Australia; and Department of Medical Bionics, University of Melbourne, Melbourne, Australia
| |
Collapse
|