1
|
Wu J, Liu J. Review of the Capacity to Accurately Detect the Temperature of Human Skin Tissue Using the Microwave Radiation Method. BIOSENSORS 2024; 14:221. [PMID: 38785695 PMCID: PMC11117873 DOI: 10.3390/bios14050221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 04/24/2024] [Accepted: 04/26/2024] [Indexed: 05/25/2024]
Abstract
Microwave radiometry (MWR) is instrumental in detecting thermal variations in skin tissue before anatomical changes occur, proving particularly beneficial in the early diagnosis of cancer and inflammation. This study concisely traces the evolution of microwave radiometers within the medical sector. By analyzing a plethora of pertinent studies and contrasting their strengths, weaknesses, and performance metrics, this research identifies the primary factors limiting temperature measurement accuracy. The review establishes the critical technologies necessary to overcome these limitations, examines the current state and prospective advancements of each technology, and proposes comprehensive implementation strategies. The discussion elucidates that the precise measurement of human surface and subcutaneous tissue temperatures using an MWR system is a complex challenge, necessitating an integration of antenna directionality for temperature measurement, radiometer error correction, hardware configuration, and the calibration and precision of a multilayer tissue forward and inversion method. This study delves into the pivotal technologies for non-invasive human tissue temperature monitoring in the microwave frequency range, offering an effective approach for the precise assessment of human epidermal and subcutaneous temperatures, and develops a non-contact microwave protocol for gauging subcutaneous tissue temperature distribution. It is anticipated that mass-produced measurement systems will deliver substantial economic and societal benefits.
Collapse
Affiliation(s)
- Jingtao Wu
- School of Information Science and Engineering, Southeast University, Nanjing 210096, China;
| | - Jie Liu
- The Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China
| |
Collapse
|
2
|
Sui K, Meneghetti M, Li G, Ioannou A, Abdollahian P, Kalli K, Nielsen K, Berg RW, Markos C. In vivo brain temperature mapping using polymer optical fiber Bragg grating sensors. OPTICS LETTERS 2023; 48:4225-4228. [PMID: 37581998 DOI: 10.1364/ol.498031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 07/21/2023] [Indexed: 08/17/2023]
Abstract
Variation of the brain temperature is strongly affected by blood flow, oxygen supply, and neural cell metabolism. Localized monitoring of the brain temperature is one of the most effective ways to correlate brain functions and diseases such as stroke, epilepsy, and mood disorders. While polymer optical fibers (POFs) are considered ideal candidates for temperature sensing in the brain, they have never been used so far in vivo. Here, we developed for the first, to the best of our knowledge, time an implantable probe based on a microstructured polymer optical fiber Bragg grating (FBG) sensor for intracranial brain temperature mapping. The temperature at different depths of the brain (starting from the cerebral cortex) and the correlation between the brain and body core temperature of a rat were recorded with a sensitivity of 33 pm/°C and accuracy <0.2°C. Our in vivo experimental results suggest that the proposed device can achieve real-time and high-resolution local temperature measurement in the brain, as well as being integrated with existing neural interfaces.
Collapse
|
3
|
Berger C, Bauer M, Wittig H, Gerlach K, Scheurer E, Lenz C. Investigation of post mortem brain, rectal and forehead temperature relations. J Therm Biol 2023; 115:103615. [PMID: 37390676 DOI: 10.1016/j.jtherbio.2023.103615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 06/05/2023] [Accepted: 06/05/2023] [Indexed: 07/02/2023]
Abstract
It is well known that magnetic resonance (MR) imaging is temperature sensitive, which is highly relevant for post mortem examinations. Therefore, the determination of the exact temperature of the investigated body site, e.g. the brain, is crucial. However, direct temperature measurements are invasive and inconvenient. Thus, in view of post mortem MR imaging of the brain, this study aims at investigating the relation between the brain and the forehead temperature for modelling the brain temperature based on the non-invasive forehead temperature. In addition, the brain temperature will be compared to the rectal temperature. Brain temperature profiles measured in the longitudinal fissure between the brain hemispheres, as well as rectal and forehead temperature profiles of 16 deceased were acquired continuously. Linear mixed, linear, quadratic and cubic models were fitted to the relation between the longitudinal fissure and the forehead and between the longitudinal fissure and the rectal temperature, respectively. Highest adjusted R2 values were found between the longitudinal fissure and the forehead temperature, as well as between the longitudinal fissure and the rectal temperature using a linear mixed model including the sex, environmental temperature and humidity as fixed effects. The results indicate that the forehead, as well as the rectal temperature, can be used to model the brain temperature measured in the longitudinal fissure. Comparable fit results were observed for the longitudinal fissure-forehead temperature relation and for the longitudinal fissure-rectal temperature relation. Combined with the fact that the forehead temperature overcomes the problem of measurement invasiveness, the results suggest using the forehead temperature for modelling the brain temperature in the longitudinal fissure.
Collapse
Affiliation(s)
- Celine Berger
- Institute of Forensic Medicine, Department of Biomedical Engineering, University of Basel, Basel, Switzerland; Institute of Forensic Medicine, Health Department Basel-Stadt, Basel, Switzerland
| | - Melanie Bauer
- Institute of Forensic Medicine, Department of Biomedical Engineering, University of Basel, Basel, Switzerland; Institute of Forensic Medicine, Health Department Basel-Stadt, Basel, Switzerland
| | - Holger Wittig
- Institute of Forensic Medicine, Department of Biomedical Engineering, University of Basel, Basel, Switzerland; Institute of Forensic Medicine, Health Department Basel-Stadt, Basel, Switzerland
| | - Kathrin Gerlach
- Institute of Forensic Medicine, Department of Biomedical Engineering, University of Basel, Basel, Switzerland; Institute of Forensic Medicine, Health Department Basel-Stadt, Basel, Switzerland
| | - Eva Scheurer
- Institute of Forensic Medicine, Department of Biomedical Engineering, University of Basel, Basel, Switzerland; Institute of Forensic Medicine, Health Department Basel-Stadt, Basel, Switzerland
| | - Claudia Lenz
- Institute of Forensic Medicine, Department of Biomedical Engineering, University of Basel, Basel, Switzerland; Institute of Forensic Medicine, Health Department Basel-Stadt, Basel, Switzerland.
| |
Collapse
|
4
|
Tisdale K, Bringer A, Kiourti A. A Core Body Temperature Retrieval Method for Microwave Radiometry when Tissue Permittivity is Unknown. IEEE JOURNAL OF ELECTROMAGNETICS, RF AND MICROWAVES IN MEDICINE AND BIOLOGY 2022; 6:470-476. [PMID: 36439285 PMCID: PMC9696197 DOI: 10.1109/jerm.2022.3171092] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
This paper presents a novel method for core temperature retrieval using microwave radiometry when complex permittivity and heat transfer parameters of the tissue layers of the human subject are unknown. Previous works present methods for core temperature retrieval, but these methods do not account for population variation in the relevant electromagnetic and thermal parameters, which can increase measurement error beyond the clinically acceptable limit of 0.5°C. Pennes' bioheat model of a six-tissue-layer human head model combined with a coherent electromagnetic model simulate experimental data. To retrieve core temperature, nonlinear least squares optimization is then used to minimize the difference between the simulated experimental data and an exponential model for physical temperature and the coherent electromagnetic model. By using 20 frequencies spanning from 1-5 GHz, core temperature is retrieved while accounting for population variation in the permittivity and thermal parameters. A Monte Carlo simulation in which the thermal parameters and permittivity vary according to literature-derived, population-representative distributions and the core body temperature varies from 18-46°C is used to assess the utility of the retrieval method. Different antenna patterns are tested to explore the effect on retrieval accuracy. The retrieval method has a retrieval error of <0.1°C when only the thermal parameters are unknown and a retrieval error of <0.5°C when the thermal parameters and permittivity are unknown, which is within the clinically acceptable error range of 0.5°C. These results help progress the field of medical microwave radiometry toward being a clinically viable noninvasive measurement that is accurate when measuring all patients.
Collapse
Affiliation(s)
- Katrina Tisdale
- The Ohio State University ElectroScience Laboratory, Columbus, OH, 43212 USA
| | - Alexandra Bringer
- The Ohio State University ElectroScience Laboratory, Columbus, OH, 43212 USA
| | - Asimina Kiourti
- The Ohio State University ElectroScience Laboratory, Columbus, OH, 43212 USA
| |
Collapse
|
5
|
Tisdale K, Bringer A, Kiourti A. Development of a Coherent Model for Radiometric Core Body Temperature Sensing. IEEE JOURNAL OF ELECTROMAGNETICS, RF AND MICROWAVES IN MEDICINE AND BIOLOGY 2022; 6:355-363. [PMID: 36034518 PMCID: PMC9400640 DOI: 10.1109/jerm.2021.3137962] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
This paper examines the utility of a wideband, physics-based model to determine human core body or brain temperature via microwave radiometry. Pennes's bioheat equation is applied to a six-layer human head model to generate the expected layered temperature profile during the development of a fever. The resulting temperature profile is fed into the forward electromagnetic (EM) model to determine the emitted brightness temperature at various points in time. To accurately retrieve physical temperature via radiometry, the utilized model must incorporate population variation statistics and cover a wide frequency band. The effect of human population variation on emitted brightness temperature is studied by varying the relevant thermal and EM parameters, and brightness temperature emissions are simulated from 0.1 MHz to 10 GHz. A Monte Carlo simulation combined with literature-derived statistical distributions for the thermal and EM parameters is performed to analyze population-level variation in resulting brightness temperature. Variation in thermal parameters affects the offset of the resulting brightness temperature signature, while EM parameter variation shifts the key maxima and minima of the signature. The layering of high and low permittivity layers creates these key maxima and minima via wave interference. This study is one of the first to apply a coherent model to and the first to examine the effect of population-representative variable distributions on radiometry for core temperature measurement. These results better inform the development of an on-body radiometer useful for core body temperature measurement across the human population.
Collapse
Affiliation(s)
- Katrina Tisdale
- Ohio State University ElectroScience Laboratory, Columbus, OH 43212 USA
| | - Alexandra Bringer
- Ohio State University ElectroScience Laboratory, Columbus, OH 43212 USA
| | - Asimina Kiourti
- Ohio State University ElectroScience Laboratory, Columbus, OH 43212 USA
| |
Collapse
|
6
|
Khoperskov AV, Polyakov MV. Improving the Efficiency of Oncological Diagnosis of the Breast Based on the Combined Use of Simulation Modeling and Artificial Intelligence Algorithms. ALGORITHMS 2022; 15:292. [DOI: 10.3390/a15080292] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2025]
Abstract
This work includes a brief overview of the applications of the powerful and easy-to-perform method of microwave radiometry (MWR) for the diagnosis of various diseases. The main goal of this paper is to develop a method for diagnosing breast oncology based on machine learning algorithms using thermometric data, both real medical measurements and simulation results of MWR examinations. The dataset includes distributions of deep and skin temperatures calculated in numerical models of the dynamics of thermal and radiation fields inside biological tissue. The constructed combined dataset allows us to explore the limits of applicability of the MWR method for detecting weak tumors. We use convolutional neural networks and classic machine learning algorithms (k-nearest neighbors, naive Bayes classifier, support vector machine) to classify data. The construction of Kohonen self-organizing maps to explore the structure of our combined dataset demonstrated differences between the temperatures of patients with positive and negative diagnoses. Our analysis shows that the MWR can detect tumors with a radius of up to 0.5 cm if they are at the stage of rapid growth, when the tumor volume doubling occurs in approximately 100 days or less. The use of convolutional neural networks for MWR provides both high sensitivity (sens=0.86) and specificity (spec=0.82), which is an advantage over other methods for diagnosing breast cancer. A new modified scheme for medical measurements of IR temperature and brightness temperature is proposed for a larger number of points in the breast compared to the classical scheme. This approach can increase the effectiveness and sensitivity of diagnostics by several percent.
Collapse
Affiliation(s)
- Alexander V. Khoperskov
- Department of Information Systems and Computer Modelling, Volgograd State University, Universitetsky pr., 100, Volgograd 400062, Russia
| | - Maxim V. Polyakov
- Department of Information Systems and Computer Modelling, Volgograd State University, Universitetsky pr., 100, Volgograd 400062, Russia
| |
Collapse
|
7
|
Goryanin I, Ovchinnikov L, Vesnin S, Ivanov Y. Monitoring Protein Denaturation of Egg White Using Passive Microwave Radiometry (MWR). Diagnostics (Basel) 2022; 12:diagnostics12061498. [PMID: 35741308 PMCID: PMC9221703 DOI: 10.3390/diagnostics12061498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 06/08/2022] [Accepted: 06/15/2022] [Indexed: 11/16/2022] Open
Abstract
Passive microwave radiometry (MWR) is a measurement technique based on the detection of passive radiation in the microwave spectrum of different objects. When in equilibrium, this radiation is known to be proportional to the thermodynamic temperature of an emitting body. We hypothesize that living systems feature other mechanisms of emission that are based on protein unfolding and water rotational transitions. To understand the nature of these emissions, microwave radiometry was used in several in vitro experiments. In our study, we performed pilot measurements of microwave emissions from egg whites during denaturation induced by ethanol. Egg whites comprise 10% proteins, such as albumins, mucoproteins, and globulins. We observed a novel phenomenon: microwave emissions changed without a corresponding change in the water’s thermodynamic temperature. We also found striking differences between microwave emissions and thermodynamic temperature kinetics. Therefore, we hypothesize that these two processes are unrelated, contrary to what was thought before. It is known that some pathologies such as stroke or brain trauma feature increased microwave emissions. We hypothesize that this phenomenon originates from protein denaturation and is not related to the thermodynamic temperature. As such, our findings could explain the reason for the increase in microwave emissions after trauma and post mortem for the first time. These findings could be used for the development of novel diagnostics methods. The MWR method is inexpensive and does not require fluorescent or radioactive labels. It can be used in different areas of basic and applied pharmaceutical research, including in kinetics studies in biomedicine.
Collapse
Affiliation(s)
- Igor Goryanin
- Okinawa Institute of Science and Technology, Onna-son, Okinawa 904-049, Japan
- School of Informatics, University of Edinburgh, Edinburgh EH8 9YL, UK
- Institute Experimental and Theoretical Biophysics, 142290 Pushchino, Russia
- Correspondence:
| | - Lev Ovchinnikov
- Medical Microwave Radiometry (MMWR) LTD, Edinburgh EH10 5LZ, UK; (L.O.); (S.V.)
| | - Sergey Vesnin
- Medical Microwave Radiometry (MMWR) LTD, Edinburgh EH10 5LZ, UK; (L.O.); (S.V.)
| | - Yuri Ivanov
- Institute of Biomedical Chemistry, 10, Pogodinskaya st., 119121 Moscow, Russia;
| |
Collapse
|
8
|
Abstract
PURPOSE OF REVIEW Fever is common after acute brain injury and is associated with poor prognosis in this setting. RECENT FINDINGS Achieving normothermia is feasible in patients with ischemic or hemorrhagic stroke, subarachnoid hemorrhage and traumatic brain injury. Pharmacological strategies (i.e. paracetamol or nonsteroidal anti-inflammatory drugs) are frequently ineffective and physical (i.e. cooling devices) therapies are often required. There are no good quality data supporting any benefit from therapeutic strategies aiming at normothermia in all brain injured patients when compared with standard of care, where mild-to-moderate fever is tolerated. However, recent guidelines recommended fever control in this setting. SUMMARY As fever is considered a clinically relevant secondary brain damage, we have provided an individualized therapeutic approach to treat it in brain injured patients, which deserved further validation in the clinical setting.
Collapse
Affiliation(s)
- Elisa Gouvea Bogossian
- Department of Intensive Care, Erasmus Hospital, Université Libre de Bruxelles (ULB), Brussels, Belgium
| | | |
Collapse
|
9
|
Paal P, Pasquier M, Darocha T, Lechner R, Kosinski S, Wallner B, Zafren K, Brugger H. Accidental Hypothermia: 2021 Update. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:501. [PMID: 35010760 PMCID: PMC8744717 DOI: 10.3390/ijerph19010501] [Citation(s) in RCA: 69] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Revised: 12/08/2021] [Accepted: 12/09/2021] [Indexed: 12/13/2022]
Abstract
Accidental hypothermia is an unintentional drop of core temperature below 35 °C. Annually, thousands die of primary hypothermia and an unknown number die of secondary hypothermia worldwide. Hypothermia can be expected in emergency patients in the prehospital phase. Injured and intoxicated patients cool quickly even in subtropical regions. Preventive measures are important to avoid hypothermia or cooling in ill or injured patients. Diagnosis and assessment of the risk of cardiac arrest are based on clinical signs and core temperature measurement when available. Hypothermic patients with risk factors for imminent cardiac arrest (temperature < 30 °C in young and healthy patients and <32 °C in elderly persons, or patients with multiple comorbidities), ventricular dysrhythmias, or systolic blood pressure < 90 mmHg) and hypothermic patients who are already in cardiac arrest, should be transferred directly to an extracorporeal life support (ECLS) centre. If a hypothermic patient arrests, continuous cardiopulmonary resuscitation (CPR) should be performed. In hypothermic patients, the chances of survival and good neurological outcome are higher than for normothermic patients for witnessed, unwitnessed and asystolic cardiac arrest. Mechanical CPR devices should be used for prolonged rescue, if available. In severely hypothermic patients in cardiac arrest, if continuous or mechanical CPR is not possible, intermittent CPR should be used. Rewarming can be accomplished by passive and active techniques. Most often, passive and active external techniques are used. Only in patients with refractory hypothermia or cardiac arrest are internal rewarming techniques required. ECLS rewarming should be performed with extracorporeal membrane oxygenation (ECMO). A post-resuscitation care bundle should complement treatment.
Collapse
Affiliation(s)
- Peter Paal
- Department of Anesthesiology and Intensive Care Medicine, St. John of God Hospital, Paracelsus Medical University, 5020 Salzburg, Austria
- International Commission for Mountain Emergency Medicine (ICAR MedCom), 8302 Kloten, Switzerland; (M.P.); (K.Z.); (H.B.)
| | - Mathieu Pasquier
- International Commission for Mountain Emergency Medicine (ICAR MedCom), 8302 Kloten, Switzerland; (M.P.); (K.Z.); (H.B.)
- Department of Emergency Medicine, Lausanne University Hospital, 1011 Lausanne, Switzerland
| | - Tomasz Darocha
- Department of Anesthesiology and Intensive Care, Medical University of Silesia, 40-001 Katowice, Poland;
| | - Raimund Lechner
- Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Therapy, Military Hospital, 89081 Ulm, Germany;
| | - Sylweriusz Kosinski
- Faculty of Health Sciences, Jagiellonian University Medical College, 34-500 Krakow, Poland;
| | - Bernd Wallner
- Department of Anesthesiology and Critical Care Medicine, Medical University of Innsbruck, 6020 Innsbruck, Austria;
| | - Ken Zafren
- International Commission for Mountain Emergency Medicine (ICAR MedCom), 8302 Kloten, Switzerland; (M.P.); (K.Z.); (H.B.)
- Department of Emergency Medicine, Alaska Native Medical Center, Anchorage, AK 99508, USA
- Department of Emergency Medicine, Stanford University Medical Center, Stanford University, Palo Alto, CA 94304, USA
| | - Hermann Brugger
- International Commission for Mountain Emergency Medicine (ICAR MedCom), 8302 Kloten, Switzerland; (M.P.); (K.Z.); (H.B.)
- Institute of Mountain Emergency Medicine, Eurac Research, 39100 Bolzano, Italy
- Department of Anesthesiology and Intensive Care Medicine, Medical University of Innsbruck, 6020 Innsbruck, Austria
| |
Collapse
|
10
|
Verma V, Lange F, Bainbridge A, Harvey-Jones K, Robertson NJ, Tachtsidis I, Mitra S. Brain temperature monitoring in newborn infants: Current methodologies and prospects. Front Pediatr 2022; 10:1008539. [PMID: 36268041 PMCID: PMC9577084 DOI: 10.3389/fped.2022.1008539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 09/15/2022] [Indexed: 02/02/2023] Open
Abstract
Brain tissue temperature is a dynamic balance between heat generation from metabolism, passive loss of energy to the environment, and thermoregulatory processes such as perfusion. Perinatal brain injuries, particularly neonatal encephalopathy, and seizures, have a significant impact on the metabolic and haemodynamic state of the developing brain, and thereby likely induce changes in brain temperature. In healthy newborn brains, brain temperature is higher than the core temperature. Magnetic resonance spectroscopy (MRS) has been used as a viable, non-invasive tool to measure temperature in the newborn brain with a reported accuracy of up to 0.2 degrees Celcius and a precision of 0.3 degrees Celcius. This measurement is based on the separation of chemical shifts between the temperature-sensitive water peaks and temperature-insensitive singlet metabolite peaks. MRS thermometry requires transport to an MRI scanner and a lengthy single-point measurement. Optical monitoring, using near infrared spectroscopy (NIRS), offers an alternative which overcomes this limitation in its ability to monitor newborn brain tissue temperature continuously at the cot side in real-time. Near infrared spectroscopy uses linear temperature-dependent changes in water absorption spectra in the near infrared range to estimate the tissue temperature. This review focuses on the currently available methodologies and their viability for accurate measurement, the potential benefits of monitoring newborn brain temperature in the neonatal intensive care unit, and the important challenges that still need to be addressed.
Collapse
Affiliation(s)
- Vinita Verma
- Institute for Women's Health, University College London, London, United Kingdom
| | - Frederic Lange
- Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Alan Bainbridge
- Medical Physics and Engineering, University College London Hospital, London, United Kingdom
| | - Kelly Harvey-Jones
- Institute for Women's Health, University College London, London, United Kingdom
| | - Nicola J Robertson
- Institute for Women's Health, University College London, London, United Kingdom
| | - Ilias Tachtsidis
- Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Subhabrata Mitra
- Institute for Women's Health, University College London, London, United Kingdom
| |
Collapse
|
11
|
Shevelev O, Petrova M, Smolensky A, Osmonov B, Toimatov S, Kharybina T, Karbainov S, Ovchinnikov L, Vesnin S, Tarakanov A, Goryanin I. Using medical microwave radiometry for brain temperature measurements. Drug Discov Today 2021; 27:881-889. [PMID: 34767961 DOI: 10.1016/j.drudis.2021.11.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 09/29/2021] [Accepted: 11/02/2021] [Indexed: 11/30/2022]
Abstract
Brain temperature (BT) is a crucial physiological parameter used to monitor cerebral status. Physical activities and traumatic brain injuries (TBI) can affect BT; therefore, non-invasive BT monitoring is an important way to gain insight into TBI, stroke, and wellbeing. The effects of BT on physical performance have been studied at length. When humans are under extreme conditions, most of the energy consumed is used to maintain the BT. In addition, measuring the BT is useful for early brain diagnostics. Passive microwave radiometry (MWR) measures the intrinsic radiation of tissues in the 1-4 GHz range. It was shown that non-invasive passive MWR technology can successfully measure BT and identify even small TBIs. Here, we review the potential applications of MWR for assessing BT.
Collapse
Affiliation(s)
- Oleg Shevelev
- People' Friendship University of Russia, Moscow, Russia; Federal Research and Clinical Centre for Resuscitation and Rehabilitation, Moscow, Russia
| | - Marina Petrova
- People' Friendship University of Russia, Moscow, Russia; Federal Research and Clinical Centre for Resuscitation and Rehabilitation, Moscow, Russia
| | - Andrey Smolensky
- Russian State University of Physical Culture, Sports, Youth and Tourism, Moscow, Russia
| | - Batyr Osmonov
- Educational - Scientifc Medical Center of Kyrgyz Medical Sate University, Bishkek, Kyrgyz Republic
| | | | - Tatyana Kharybina
- Library for Natural Sciences of the Russian Academy of Sciences, Moscow, Russia
| | | | | | - Sergey Vesnin
- Medical Microwave Radiometry Ltd, Edinburgh, UK; RTM Diagnostic LLC, Moscow, Russia; Bauman Moscow State Technical University, Moscow, Russia
| | | | - Igor Goryanin
- School of Informatics, University of Edinburgh, Edinburgh, UK; Institute Theoretical and Experimental Biophysics, Pushchino, Russia; Okinawa Institute Science and Technology, Okinawa, Japan.
| |
Collapse
|
12
|
Ischemia-Reperfusion Injuries Assessment during Pancreas Preservation. Int J Mol Sci 2021; 22:ijms22105172. [PMID: 34068301 PMCID: PMC8153272 DOI: 10.3390/ijms22105172] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Revised: 04/25/2021] [Accepted: 05/10/2021] [Indexed: 12/20/2022] Open
Abstract
Maintaining organ viability between donation and transplantation is of critical importance for optimal graft function and survival. To date in pancreas transplantation, static cold storage (SCS) is the most widely practiced method of organ preservation. The first experiments in ex vivo perfusion of the pancreas were performed at the beginning of the 20th century. These perfusions led to organ oedema, hemorrhage, and venous congestion after revascularization. Despite these early hurdles, a number of factors now favor the use of perfusion during preservation: the encouraging results of HMP in kidney transplantation, the development of new perfusion solutions, and the development of organ perfusion machines for the lung, heart, kidneys and liver. This has led to a resurgence of research in machine perfusion for whole organ pancreas preservation. This review highlights the ischemia-reperfusion injuries assessment during ex vivo pancreas perfusion, both for assessment in pre-clinical experimental models as well for future use in the clinic. We evaluated perfusion dynamics, oedema assessment, especially by impedance analysis and MRI, whole organ oxygen consumption, tissue oxygen tension, metabolite concentrations in tissue and perfusate, mitochondrial respiration, cell death, especially by histology, total cell free DNA, caspase activation, and exocrine and endocrine assessment.
Collapse
|
13
|
Zhang B, Wang Y, Zhao Z, Han B, Yang J, Sun Y, Zhang B, Zang Y, Guan H. Temperature Plays an Essential Regulatory Role in the Tumor Immune Microenvironment. J Biomed Nanotechnol 2021; 17:169-195. [PMID: 33785090 DOI: 10.1166/jbn.2021.3030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In recent years, emerging immunotherapy has been included in various malignant tumor treatment standards. Temperature has been considered to affect different pathophysiological reactions such as inflammation and cancer for a long time. However, in tumor immunology research, temperature is still rarely considered a significant variable. In this review, we discuss the effects of room temperature, body temperature, and the local tumor temperature on the tumor immune microenvironment from multiple levels and perspectives, and we discuss changes in the body's local and whole-body temperature under tumor conditions. We analyze the current use of ablation treatment-the reason for the opposite immune effect. We should pay more attention to the therapeutic potential of temperature and create a better antitumor microenvironment that can be combined with immunotherapy.
Collapse
Affiliation(s)
- Bin Zhang
- Marine Drug and Food Institute, Ocean University of China, Qingdao, Shandong, 266100, China
| | - Youpeng Wang
- Department of Hepatobiliary and Pancreatic Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, 266003, China
| | - Ziyin Zhao
- Organ Transplantation Center, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, 266003, China
| | - Bing Han
- Department of Hepatobiliary and Pancreatic Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, 266003, China
| | - Jinbo Yang
- Marine Drug and Food Institute, Ocean University of China, Qingdao, Shandong, 266100, China
| | - Yang Sun
- Marine Drug and Food Institute, Ocean University of China, Qingdao, Shandong, 266100, China
| | - Bingyuan Zhang
- Department of Hepatobiliary and Pancreatic Surgery, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, 266003, China
| | - Yunjin Zang
- Organ Transplantation Center, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, 266003, China
| | - Huashi Guan
- Marine Drug and Food Institute, Ocean University of China, Qingdao, Shandong, 266100, China
| |
Collapse
|
14
|
Guido K, Bringer A, Kiourti A. Toward Non-Invasive Core Body Temperature Sensing. PROCEEDINGS. USNC-URSI RADIO SCIENCE MEETING 2021; 2021:164-165. [PMID: 33693311 PMCID: PMC7943173 DOI: 10.23919/usnc-ursinrsm51531.2021.9336477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
This paper aims to explore the potential of a novel radiometry technique that leverages bio-matched antennas (BMAs), broadband measurements, and forward modeling of layered tissues for non-invasive and accurate core temperature monitoring. Our approach relies on the observation that electromagnetic waves penetrate to different depths depending on their frequency and dielectric properties of the medium and adapts radiative transfer models that have been successfully implemented in the past for layered geophysical media. Preliminary modeling and experimental results confirm feasibility.
Collapse
Affiliation(s)
- Katrina Guido
- ElectroScience Laboratory, Department of Electrical and Computer Engineering, The Ohio State University Columbus, OH, USA
| | - Alexandra Bringer
- ElectroScience Laboratory, Department of Electrical and Computer Engineering, The Ohio State University Columbus, OH, USA
| | - Asimina Kiourti
- ElectroScience Laboratory, Department of Electrical and Computer Engineering, The Ohio State University Columbus, OH, USA
| |
Collapse
|
15
|
Meaney P, Hartov A, Raynolds T, Davis C, Richter S, Schoenberger F, Geimer S, Paulsen K. Low Cost, High Performance, 16-Channel Microwave Measurement System for Tomographic Applications. SENSORS 2020; 20:s20185436. [PMID: 32971940 PMCID: PMC7570920 DOI: 10.3390/s20185436] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 09/16/2020] [Accepted: 09/17/2020] [Indexed: 12/26/2022]
Abstract
We have developed a multichannel software defined radio-based transceiver measurement system for use in general microwave tomographic applications. The unit is compact enough to fit conveniently underneath the current illumination tank of the Dartmouth microwave breast imaging system. The system includes 16 channels that can both transmit and receive and it operates from 500 MHz to 2.5 GHz while measuring signals down to −140 dBm. As is the case with multichannel systems, cross-channel leakage is an important specification and must be lower than the noise floors for each receiver. This design exploits the isolation inherent when the individual receivers for each channel are physically separate; however, these challenging specifications require more involved signal isolation techniques at both the system design level and the individual, shielded component level. We describe the isolation design techniques for the critical system elements and demonstrate specification compliance at both the component and system level.
Collapse
Affiliation(s)
- Paul Meaney
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA; (A.H.); (T.R.); (S.G.); (K.P.)
- Correspondence: ; Tel.: +1-603-646-3939
| | - Alexander Hartov
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA; (A.H.); (T.R.); (S.G.); (K.P.)
| | - Timothy Raynolds
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA; (A.H.); (T.R.); (S.G.); (K.P.)
| | | | - Sebastian Richter
- German Federal Ministry of Defense, 2E1202 Hamburg, Germany; (S.R.); (F.S.)
| | | | - Shireen Geimer
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA; (A.H.); (T.R.); (S.G.); (K.P.)
| | - Keith Paulsen
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA; (A.H.); (T.R.); (S.G.); (K.P.)
| |
Collapse
|
16
|
Raiko J, Koskensalo K, Sainio T. Imaging-based internal body temperature measurements: The journal Temperature toolbox. Temperature (Austin) 2020; 7:363-388. [PMID: 33251282 PMCID: PMC7678923 DOI: 10.1080/23328940.2020.1769006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Revised: 05/08/2020] [Accepted: 05/11/2020] [Indexed: 12/27/2022] Open
Abstract
Noninvasive imaging methods of internal body temperature are in high demand in both clinical medicine and physiological research. Thermography and thermometry can be used to assess tissue temperature during thermal therapies: ablative and hyperthermia treatments to ensure adequate temperature rise in target tissues but also to avoid collateral damage by heating healthy tissues. In research use, measurement of internal body temperature enables us the production of thermal maps on muscles, internal organs, and other tissues of interest. The most used methods for noninvasive imaging of internal body temperature are based on different parameters acquired with magnetic resonance imaging, ultrasound, computed tomography, microwave radiometry, photoacoustic imaging, and near-infrared spectroscopy. In the current review, we examine the aforementioned imaging methods, their use in estimating internal body temperature in vivo with their advantages and disadvantages, and the physical phenomena the thermography or thermometry modalities are based on.
Collapse
Affiliation(s)
- Juho Raiko
- Turku PET Centre, University of Turku, Turku, Finland
- Department of Nutrition and Movement Sciences, Maastricht University, Maastricht, The Netherlands
| | - Kalle Koskensalo
- Department of Medical Physics, Turku University Hospital, Turku, Finland
| | - Teija Sainio
- Department of Medical Physics, Turku University Hospital, Turku, Finland
| |
Collapse
|
17
|
Goryanin I, Karbainov S, Shevelev O, Tarakanov A, Redpath K, Vesnin S, Ivanov Y. Passive microwave radiometry in biomedical studies. Drug Discov Today 2020; 25:757-763. [PMID: 32004473 DOI: 10.1016/j.drudis.2020.01.016] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 12/21/2019] [Accepted: 01/22/2020] [Indexed: 01/30/2023]
Abstract
Passive microwave radiometry (MWR) measures natural emissions in the range 1-10GHz from proteins, cells, organs and the whole human body. The intensity of intrinsic emission is determined by biochemical and biophysical processes. The nature of this process is still not very well known. Infrared thermography (IRT) can detect emission several microns deep (skin temperature), whereas MWR allows detection of thermal abnormalities down to several centimeters (internal or deep temperature). MWR is noninvasive and inexpensive. It requires neither fluorescent nor radioactive labels, nor ionizing or other radiation. MWR can be used in early drug discovery as well as preclinical and clinical studies.
Collapse
Affiliation(s)
- Igor Goryanin
- University of Edinburgh, UK; Okinawa Institute Science and Technology, Okinawa, Japan; Tianjin Institute of Industrial Biotechnology, Tianjin, China.
| | | | - Oleg Shevelev
- Peoples' Friendship University of Russia, Moscow, Russia
| | | | - Keith Redpath
- Manus Neurodynamica, Edinburgh, UK; Medical Microwave Radiometry (MMWR), Edinburgh, UK
| | - Sergey Vesnin
- Medical Microwave Radiometry (MMWR), Edinburgh, UK; Bauman Moscow State Technical University (BMSTU), Moscow, Russia
| | - Yuri Ivanov
- Institute of Biomedical Chemistry (IBMC), Moscow, Russia; Joint Institute for High Temperatures of the RAS, Moscow, Russia
| |
Collapse
|
18
|
Ravi VM, Sharma AK, Arunachalam K. Pre-Clinical Testing of Microwave Radiometer and a Pilot Study on the Screening Inflammation of Knee Joints. Bioelectromagnetics 2019; 40:402-411. [PMID: 31310336 DOI: 10.1002/bem.22203] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Accepted: 06/12/2019] [Indexed: 11/10/2022]
Abstract
This article presents the pre-clinical evaluation of our custom-built, single-band microwave radiometer centered at 1.3 GHz for deep tissue thermometry, and a pilot study on volunteers for passive detection of inflammation in knee joints. The electromagnetic (EM) compatibility of the battery-operated radiometer for clinical use was assessed as per International Special Committee on Radio Interference (CISPR) 22 standard. The ability to detect inflammation in knee joints was assessed using a substrate integrated waveguide antenna connected to the radiometer. EM compatibility tests carried out in the laboratory indicated device immunity to intentional radiated interference up to -20 dBm injected power in the global system for mobile communication frequency band, and pre-compliance to CISPR 22 standard. Radiometer temperature measurements recorded at the lateral and medial aspects of both knees of 41 volunteers indicated mean temperature greater than 33°C for the diseased sites compared with the mean temperature of 28°C measured for the healthy sites. One-way analysis of variance statistics indicated significantly (P < 0.005) higher radiometer temperature at the diseased sites unlike the healthy sites. Thus, the EM pre-compliance of the device and the potential to measure deep tissue inflammation were demonstrated. Bioelectromagnetics. 2019;40:402-411. © 2019 Bioelectromagnetics Society.
Collapse
Affiliation(s)
- Vidyalakshmi M Ravi
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai, India
| | - Amit K Sharma
- Institute Hospital, Indian Institute of Technology Madras, Chennai, India
| | - Kavitha Arunachalam
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai, India
| |
Collapse
|
19
|
Groumpas E, Koutsoupidou M, Karanasiou IS, Papageorgiou C, Uzunoglu N. Real-Time Passive Brain Monitoring System Using Near-Field Microwave Radiometry. IEEE Trans Biomed Eng 2019; 67:158-165. [PMID: 30969913 DOI: 10.1109/tbme.2019.2909994] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Near-field microwave radiometry has emerged as a tool for real-time passive monitoring of local brain activation, possibly attributed to local changes in blood flow that correspond to temperature and/or conductivity changes. The aim of this study is to design and evaluate a prototype system based on microwave radiometry intended to detect local changes of temperature and conductivity in depth in brain tissues. A novel radiometric system that comprises a four port total power Dicke-switch sensitive receiver that operates at 1.5 GHz has been developed. METHODS AND RESULTS The efficacy of the system was assessed through simulation and experiment on brain tissue mimicking phantoms under different setup conditions, where temperature and conductivity changes were accurately detected. In order to validate the radiometer's capability to sense low power signals occurring spontaneously from regions in the human brain, the somatosensory cortices of one volunteer were measured under pain-inducing psychophysiological conditions. The promising results from the initial in vivo measurements prove the system's potential for more extensive investigative trials. CONCLUSION AND SIGNIFICANCE The significance of this study lies on the development of a compact and sensitive radiometer for totally passive monitoring of local brain activation as a potential complementary tool for contributing to the research effort for investigating brain functionality.
Collapse
|
20
|
Development of Body-Tissue Temperature-Control Transducer. SENSORS 2018; 19:s19010014. [PMID: 30577508 PMCID: PMC6339162 DOI: 10.3390/s19010014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Revised: 12/13/2018] [Accepted: 12/17/2018] [Indexed: 01/09/2023]
Abstract
The aim of this study was to develop a transducer for non-invasive temperature measurement in deeper tissue layers during tissue cooling. Simulation of the temperature field distribution in human tissues and the transducer were done, and the influence of transducer structure and material properties were studied. Using simulation results, the experimental transducer was designed for temperature measurement in deeper tissue layers during cooling. The temperature measurements with the needle thermometer and the transducer were well correlated at both before tissue cooling r = 0.723 and after cooling r = 0.945, and the temperature difference was no more than ±0.2 °C.
Collapse
|
21
|
Ma M, Zhang Y, Gu N. Estimation the tumor temperature in magnetic nanoparticle hyperthermia by infrared thermography: Phantom and numerical studies. J Therm Biol 2018; 76:89-94. [DOI: 10.1016/j.jtherbio.2018.07.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 07/06/2018] [Accepted: 07/09/2018] [Indexed: 10/28/2022]
|
22
|
Ivanov Y, Kozlov AF, Galiullin RA, Tatur VY, Ziborov VS, Ivanova ND, Pleshakova TO, Vesnin SG, Goryanin I. Use of Microwave Radiometry to Monitor Thermal Denaturation of Albumin. Front Physiol 2018; 9:956. [PMID: 30090068 PMCID: PMC6068392 DOI: 10.3389/fphys.2018.00956] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 06/29/2018] [Indexed: 11/25/2022] Open
Abstract
This study monitored thermal denaturation of albumin using microwave radiometry. Brightness Temperature, derived from Microwave Emission (BTME) of an aqueous solution of bovine serum albumin (0.1 mM) was monitored in the microwave frequency range 3.8–4.2 GHz during denaturation of this protein at a temperature of 56°C in a conical polypropylene cuvette. This method does not require fluorescent or radioactive labels. A microwave emission change of 1.5–2°C in the BTME of aqueous albumin solution was found during its denaturation, without a corresponding change in the water temperature. Radio thermometry makes it possible to monitor protein denaturation kinetics, and the resulting rate constant for albumin denaturation was 0.2 ± 0.1 min−1, which corresponds well to rate constants obtained by other methods.
Collapse
Affiliation(s)
- Yuri Ivanov
- Institute of Biomedical Chemistry, Moscow, Russia
| | | | | | - Vadim Y Tatur
- Foundation of Advanced Technologies and Innovations, Moscow, Russia
| | - Vadim S Ziborov
- Joint Institute for High Temperatures of Russian Academy of Sciences (RAS), Moscow, Russia
| | - Nina D Ivanova
- Moscow State Academy of Veterinary Medicine and Biotechnology, Moscow, Russia
| | | | - Sergey G Vesnin
- RES LTD, Moscow, Russia.,Medical MicroWave Radiometry (MMWR) LTD, Edinburgh, United Kingdom
| | - Igor Goryanin
- School of Informatics, University of Edinburgh, Edinburgh, United Kingdom.,Biological Systems Unit, Okinawa Institute of Science and Technology, Okinawa, Japan.,Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences, Tianjin, China
| |
Collapse
|
23
|
Koutsoupidou M, Groumpas E, Karanasiou IS, Christopoulou M, Nikita K, Uzunoglu N. The effect of using a dielectric matching medium in focused microwave radiometry: an anatomically detailed head model study. Med Biol Eng Comput 2017; 56:809-816. [PMID: 29027087 DOI: 10.1007/s11517-017-1729-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Accepted: 10/04/2017] [Indexed: 11/29/2022]
Abstract
Microwave radiometry is a passive technique used to measure in-depth temperature distributions inside the human body, potentially useful in clinical applications. Experimental data imply that it may provide the capability of detecting in-depth local variations of temperature and/or conductivity of excitable tissues at microwave frequencies. Specifically, microwave radiometry may allow the real-time monitoring of brain temperature and/or conductivity changes, associated with local brain activation. In this paper, recent results of our ongoing research regarding the capabilities of focused microwave radiometry for brain intracranial applications are presented. Electromagnetic and thermal simulation analysis was performed using an anatomically detailed head model and a dielectric cap as matching medium placed around it, in order to improve the sensitivity and the focusing attributes of the system. The theoretical results were compared to experimental data elicited while exploring that the sensing depth and spatial resolution of the proposed imaging method at 2.1 GHz areas located 3 cm deep inside the brain can be measured, while at 2.5 GHz, the sensing area is confined specifically to the area of interest. The results exhibit the system's potential as a complementary brain imaging tool for multifrequency in-depth passive monitoring which could be clinically useful for therapeutic, diagnostic, and research applications.
Collapse
Affiliation(s)
- Maria Koutsoupidou
- School of Electrical and Computer Engineering, National Technical University of Athens, Zografou Campus, Athens, Greece. .,School of Natural & Mathematical Sciences, King's College London, Strand Campus, London, UK.
| | - Evangelos Groumpas
- School of Electrical and Computer Engineering, National Technical University of Athens, Zografou Campus, Athens, Greece
| | - Irene S Karanasiou
- School of Electrical and Computer Engineering, National Technical University of Athens, Zografou Campus, Athens, Greece.,Department of Mathematics and Engineering Science, Hellenic Army University, Vari, Athens, Greece
| | - Maria Christopoulou
- School of Electrical and Computer Engineering, National Technical University of Athens, Zografou Campus, Athens, Greece
| | - Konstantina Nikita
- School of Electrical and Computer Engineering, National Technical University of Athens, Zografou Campus, Athens, Greece
| | - Nikolaos Uzunoglu
- School of Electrical and Computer Engineering, National Technical University of Athens, Zografou Campus, Athens, Greece
| |
Collapse
|
24
|
Packett RDM, Brown PJ, Popli GSS, Scott Gayzik F. Development and Validation of a Brain Phantom for Therapeutic Cooling Devices. J Biomech Eng 2017; 139:2612565. [PMID: 28291867 DOI: 10.1115/1.4036215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Indexed: 11/08/2022]
Abstract
Tissue cooling has been proven as a viable therapy for multiple conditions and injuries and has been applied to the brain to treat epilepsy and concussions, leading to improved long-term outcomes. To facilitate the study of temperature reduction as a function of various cooling methods, a thermal brain phantom was developed and analyzed. The phantom is composed of a potassium-neutralized, superabsorbent copolymer hydrogel. The phantom was tested in a series of cooling trials using a cooling block and 37 deg water representing nondirectional blood flow ranging up to 6 gph, a physiologically representative range based on the prototype volume. Results were compared against a validated finite difference (FD) model. Two sets of parameters were used in the FD model: one set to represent the phantom itself and a second set to represent brain parenchyma. The model was then used to calculate steady-state cooling at a depth of 5 mm for all flow rates, for both the phantom and a model of the brain. This effort was undertaken to (1) validate the FD model against the phantom results and (2) evaluate how similar the thermal response of the phantom is to that of a perfused brain. The FD phantom model showed good agreement with the empirical phantom results. Furthermore, the empirical phantom agreed with the predicted brain response within 3.5% at physiological flow, suggesting a biofidelic thermal response. The phantom will be used as a platform for future studies of thermally mediated therapies applied to the cerebral cortex.
Collapse
Affiliation(s)
- Ryan D M Packett
- Department of Biomedical Engineering, Wake Forest University, 575?N. Patterson Avenue Suite 120, Winston-Salem, NC 27101 e-mail:
| | - Philip J Brown
- Department of Biomedical Engineering, Wake Forest University, 575?N. Patterson Avenue Suite 120, Winston-Salem, NC 27101 e-mail:
| | - Gautam S S Popli
- Department of Neurology, Wake Forest Baptist Medical Center, Medical Center Boulevard, Winston-Salem, NC 27104 e-mail:
| | - F Scott Gayzik
- Mem. ASME Department of Biomedical Engineering, Wake Forest University, 575?N. Patterson Avenue Suite 120, Winston-Salem, NC 27101 e-mail:
| |
Collapse
|
25
|
Holper L, Mitra S, Bale G, Robertson N, Tachtsidis I. Prediction of brain tissue temperature using near-infrared spectroscopy. NEUROPHOTONICS 2017; 4:021106. [PMID: 28630878 PMCID: PMC5469395 DOI: 10.1117/1.nph.4.2.021106] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Accepted: 05/15/2017] [Indexed: 08/17/2023]
Abstract
Broadband near-infrared spectroscopy (NIRS) can provide an endogenous indicator of tissue temperature based on the temperature dependence of the water absorption spectrum. We describe a first evaluation of the calibration and prediction of brain tissue temperature obtained during hypothermia in newborn piglets (animal dataset) and rewarming in newborn infants (human dataset) based on measured body (rectal) temperature. The calibration using partial least squares regression proved to be a reliable method to predict brain tissue temperature with respect to core body temperature in the wavelength interval of 720 to 880 nm with a strong mean predictive power of [Formula: see text] (animal dataset) and [Formula: see text] (human dataset). In addition, we applied regression receiver operating characteristic curves for the first time to evaluate the temperature prediction, which provided an overall mean error bias between NIRS predicted brain temperature and body temperature of [Formula: see text] (animal dataset) and [Formula: see text] (human dataset). We discuss main methodological aspects, particularly the well-known aspect of over- versus underestimation between brain and body temperature, which is relevant for potential clinical applications.
Collapse
Affiliation(s)
- Lisa Holper
- University of Zurich, Hospital of Psychiatry, Department of Psychiatry, Psychotherapy, and Psychosomatics, Zurich, Switzerland
| | - Subhabrata Mitra
- University College London and Neonatal Unit, University College London Hospitals Trust, Institute for Women’s Health, London, United Kingdom
| | - Gemma Bale
- University College London, Biomedical Optics Research Laboratory, Department of Medical Physics and Biomedical Engineering, London, United Kingdom
| | - Nicola Robertson
- University College London and Neonatal Unit, University College London Hospitals Trust, Institute for Women’s Health, London, United Kingdom
| | - Ilias Tachtsidis
- University College London, Biomedical Optics Research Laboratory, Department of Medical Physics and Biomedical Engineering, London, United Kingdom
| |
Collapse
|
26
|
Salota V, Slovakova Z, Panes C, Nundlall A, Goonasekera C. Is postoperative tympanic membrane temperature measurement effective? ACTA ACUST UNITED AC 2016; 25:490-3. [DOI: 10.12968/bjon.2016.25.9.490] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Vishal Salota
- Registrar, Anaesthetics, King's College Hospital, Denmark Hill, London
| | | | | | - Anitha Nundlall
- Modern Matron (Anaesthetics & Recovery), King's College Hospital, Denmark Hill, London
| | - Chulananda Goonasekera
- Consultant Anaesthetist, Department of Anaesthetics, King's College Hospital, Denmark Hill, London
| |
Collapse
|
27
|
Schooneveldt G, Bakker A, Balidemaj E, Chopra R, Crezee J, Geijsen ED, Hartmann J, Hulshof MC, Kok HP, Paulides MM, Sousa-Escandon A, Stauffer PR, Maccarini PF. Thermal dosimetry for bladder hyperthermia treatment. An overview. Int J Hyperthermia 2016; 32:417-33. [DOI: 10.3109/02656736.2016.1156170] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
|
28
|
Rodrigues DB, Stauffer PR, Colebeck E, Hood AZ, Salahi S, Maccarini PF, Topsakal E. Dielectric properties measurements of brown and white adipose tissue in rats from 0.5 to 10 GHz. Biomed Phys Eng Express 2016; 2:025005. [PMID: 29354288 PMCID: PMC5773071 DOI: 10.1088/2057-1976/2/2/025005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Brown adipose tissue (BAT) plays an important role in whole body metabolism and with appropriate stimulus could potentially mediate weight gain and insulin sensitivity. Although imaging techniques are available to detect subsurface BAT, there are currently no viable methods for continuous acquisition of BAT energy expenditure. Microwave (MW) radiometry is an emerging technology that allows the quantification of tissue temperature variations at depths of several centimeters. Such temperature differentials may be correlated with variations in metabolic rate, thus providing a quantitative approach to monitor BAT metabolism. In order to optimize MW radiometry, numerical and experimental phantoms with accurate dielectric properties are required to develop and calibrate radiometric sensors. Thus, we present for the first time, the characterization of relative permittivity and electrical conductivity of brown (BAT) and white (WAT) adipose tissues in rats across the MW range 0.5-10GHz. Measurements were carried out in situ and post mortem in six female rats of approximately 200g. A Cole-Cole model was used to fit the experimental data into a parametric model that describes the variation of dielectric properties as a function of frequency. Measurements confirm that the dielectric properties of BAT (εr = 14.0-19.4, σ = 0.3-3.3S/m) are significantly higher than those of WAT (εr = 9.1-11.9, σ = 0.1-1.9S/m), in accordance with the higher water content of BAT.
Collapse
Affiliation(s)
- D B Rodrigues
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - P R Stauffer
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - E Colebeck
- Department of Electrical and Computer Engineering, Mississippi State University, Starkville, MS 39762, USA
| | - A Z Hood
- Department of Electrical and Computer Engineering, Mississippi State University, Starkville, MS 39762, USA
| | | | - P F Maccarini
- Department of Biomedical Engineering, Duke University, Durham, NC 27710, USA
| | - E Topsakal
- Department of Electrical and Computer Engineering, Mississippi State University, Starkville, MS 39762, USA
- Department of Electrical and Computer Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
| |
Collapse
|
29
|
Li XP, Xia Q, Qu D, Wu TC, Yang DG, Hao WD, Jiang X, Li XM. The dynamic dielectric at a brain functional site and an EM wave approach to functional brain imaging. Sci Rep 2014; 4:6893. [PMID: 25367217 PMCID: PMC4219156 DOI: 10.1038/srep06893] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2014] [Accepted: 10/15/2014] [Indexed: 11/12/2022] Open
Abstract
Functional brain imaging has tremendous applications. The existing methods for functional brain imaging include functional Magnetic Resonant Imaging (fMRI), scalp electroencephalography (EEG), implanted EEG, magnetoencephalography (MEG) and Positron Emission Tomography (PET), which have been widely and successfully applied to various brain imaging studies. To develop a new method for functional brain imaging, here we show that the dielectric at a brain functional site has a dynamic nature, varying with local neuronal activation as the permittivity of the dielectric varies with the ion concentration of the extracellular fluid surrounding neurons in activation. Therefore, the neuronal activation can be sensed by a radiofrequency (RF) electromagnetic (EM) wave propagating through the site as the phase change of the EM wave varies with the permittivity. Such a dynamic nature of the dielectric at a brain functional site provides the basis for an RF EM wave approach to detecting and imaging neuronal activation at brain functional sites, leading to an RF EM wave approach to functional brain imaging.
Collapse
Affiliation(s)
- X P Li
- Neuroengineering Lab, National University of Singapore, 9 Engineering Drive 1, Singapore 117575
| | - Q Xia
- Newrocare Pte Ltd, 6 EU Tong Sen Street, #12-03, The Central, Singapore 059817
| | - D Qu
- Neuroengineering Lab, National University of Singapore, 9 Engineering Drive 1, Singapore 117575
| | - T C Wu
- Neuroengineering Lab, National University of Singapore, 9 Engineering Drive 1, Singapore 117575
| | - D G Yang
- Guilin University of Electronic Technology, No.1 Jinji Road, Guilin 541004, Guangxi, P.R. China
| | - W D Hao
- Guilin University of Electronic Technology, No.1 Jinji Road, Guilin 541004, Guangxi, P.R. China
| | - X Jiang
- Guilin University of Electronic Technology, No.1 Jinji Road, Guilin 541004, Guangxi, P.R. China
| | - X M Li
- Guilin University of Electronic Technology, No.1 Jinji Road, Guilin 541004, Guangxi, P.R. China
| |
Collapse
|