1
|
Zhang J, Maksaev G, Yuan P. Open structure and gating of the Arabidopsis mechanosensitive ion channel MSL10. Nat Commun 2023; 14:6284. [PMID: 37805510 PMCID: PMC10560256 DOI: 10.1038/s41467-023-42117-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 09/29/2023] [Indexed: 10/09/2023] Open
Abstract
Plants are challenged by drastically different osmotic environments during growth and development. Adaptation to these environments often involves mechanosensitive ion channels that can detect and respond to mechanical force. In the model plant Arabidopsis thaliana, the mechanosensitive channel MSL10 plays a crucial role in hypo-osmotic shock adaptation and programmed cell death induction, but the molecular basis of channel function remains poorly understood. Here, we report a structural and electrophysiological analysis of MSL10. The cryo-electron microscopy structures reveal a distinct heptameric channel assembly. Structures of the wild-type channel in detergent and lipid environments, and in the absence of membrane tension, capture an open conformation. Furthermore, structural analysis of a non-conductive mutant channel demonstrates that reorientation of phenylalanine side chains alone, without main chain rearrangements, may generate the hydrophobic gate. Together, these results reveal a distinct gating mechanism and advance our understanding of mechanotransduction.
Collapse
Affiliation(s)
- Jingying Zhang
- Department of Cell Biology and Physiology, Washington University School of Medicine, Saint Louis, MO, USA
- Center for the Investigation of Membrane Excitability Diseases, Washington University School of Medicine, Saint Louis, MO, USA
- Department of Pharmacological Sciences, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Grigory Maksaev
- Department of Cell Biology and Physiology, Washington University School of Medicine, Saint Louis, MO, USA
- Center for the Investigation of Membrane Excitability Diseases, Washington University School of Medicine, Saint Louis, MO, USA
| | - Peng Yuan
- Department of Cell Biology and Physiology, Washington University School of Medicine, Saint Louis, MO, USA.
- Center for the Investigation of Membrane Excitability Diseases, Washington University School of Medicine, Saint Louis, MO, USA.
- Department of Pharmacological Sciences, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- Department of Neuroscience, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
| |
Collapse
|
2
|
Flegler VJ, Rasmussen T, Böttcher B. How Functional Lipids Affect the Structure and Gating of Mechanosensitive MscS-like Channels. Int J Mol Sci 2022; 23:ijms232315071. [PMID: 36499396 PMCID: PMC9739000 DOI: 10.3390/ijms232315071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 11/21/2022] [Accepted: 11/23/2022] [Indexed: 12/04/2022] Open
Abstract
The ability to cope with and adapt to changes in the environment is essential for all organisms. Osmotic pressure is a universal threat when environmental changes result in an imbalance of osmolytes inside and outside the cell which causes a deviation from the normal turgor. Cells have developed a potent system to deal with this stress in the form of mechanosensitive ion channels. Channel opening releases solutes from the cell and relieves the stress immediately. In bacteria, these channels directly sense the increased membrane tension caused by the enhanced turgor levels upon hypoosmotic shock. The mechanosensitive channel of small conductance, MscS, from Escherichia coli is one of the most extensively studied examples of mechanically stimulated channels. Different conformational states of this channel were obtained in various detergents and membrane mimetics, highlighting an intimate connection between the channel and its lipidic environment. Associated lipids occupy distinct locations and determine the conformational states of MscS. Not all these features are preserved in the larger MscS-like homologues. Recent structures of homologues from bacteria and plants identify common features and differences. This review discusses the current structural and functional models for MscS opening, as well as the influence of certain membrane characteristics on gating.
Collapse
|
3
|
Cyclodextrins increase membrane tension and are universal activators of mechanosensitive channels. Proc Natl Acad Sci U S A 2021; 118:2104820118. [PMID: 34475213 DOI: 10.1073/pnas.2104820118] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 07/29/2021] [Indexed: 11/18/2022] Open
Abstract
The bacterial mechanosensitive channel of small conductance (MscS) has been extensively studied to understand how mechanical forces are converted into the conformational changes that underlie mechanosensitive (MS) channel gating. We showed that lipid removal by β-cyclodextrin can mimic membrane tension. Here, we show that all cyclodextrins (CDs) can activate reconstituted Escherichia coli MscS, that MscS activation by CDs depends on CD-mediated lipid removal, and that the CD amount required to gate MscS scales with the channel's sensitivity to membrane tension. Importantly, cholesterol-loaded CDs do not activate MscS. CD-mediated lipid removal ultimately causes MscS desensitization, which we show is affected by the lipid environment. While many MS channels respond to membrane forces, generalized by the "force-from-lipids" principle, their different molecular architectures suggest that they use unique ways to convert mechanical forces into conformational changes. To test whether CDs can also be used to activate other MS channels, we chose to investigate the mechanosensitive channel of large conductance (MscL) and demonstrate that CDs can also activate this structurally unrelated channel. Since CDs can open the least tension-sensitive MS channel, MscL, they should be able to open any MS channel that responds to membrane tension. Thus, CDs emerge as a universal tool for the structural and functional characterization of unrelated MS channels.
Collapse
|
4
|
Flegler VJ, Rasmussen A, Borbil K, Boten L, Chen HA, Deinlein H, Halang J, Hellmanzik K, Löffler J, Schmidt V, Makbul C, Kraft C, Hedrich R, Rasmussen T, Böttcher B. Mechanosensitive channel gating by delipidation. Proc Natl Acad Sci U S A 2021; 118:e2107095118. [PMID: 34376558 PMCID: PMC8379960 DOI: 10.1073/pnas.2107095118] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
The mechanosensitive channel of small conductance (MscS) protects bacteria against hypoosmotic shock. It can sense the tension in the surrounding membrane and releases solutes if the pressure in the cell is getting too high. The membrane contacts MscS at sensor paddles, but lipids also leave the membrane and move along grooves between the paddles to reside as far as 15 Å away from the membrane in hydrophobic pockets. One sensing model suggests that a higher tension pulls lipids from the grooves back to the membrane, which triggers gating. However, it is still unclear to what degree this model accounts for sensing and what contribution the direct interaction of the membrane with the channel has. Here, we show that MscS opens when it is sufficiently delipidated by incubation with the detergent dodecyl-β-maltoside or the branched detergent lauryl maltose neopentyl glycol. After addition of detergent-solubilized lipids, it closes again. These results support the model that lipid extrusion causes gating: Lipids are slowly removed from the grooves and pockets by the incubation with detergent, which triggers opening. Addition of lipids in micelles allows lipids to migrate back into the pockets, which closes the channel even in the absence of a membrane. Based on the distribution of the aliphatic chains in the open and closed conformation, we propose that during gating, lipids leave the complex on the cytosolic leaflet at the height of highest lateral tension, while on the periplasmic side, lipids flow into gaps, which open between transmembrane helices.
Collapse
Affiliation(s)
| | - Akiko Rasmussen
- Lehrstuhl für Botanik I, Julius-Maximilians-Universität Würzburg, 97082 Würzburg, Germany
| | - Karina Borbil
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany
| | - Lea Boten
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany
| | - Hsuan-Ai Chen
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany
| | - Hanna Deinlein
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany
| | - Julia Halang
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany
| | - Kristin Hellmanzik
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany
| | - Jessica Löffler
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany
| | - Vanessa Schmidt
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany
| | - Cihan Makbul
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany
| | - Christian Kraft
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany
| | - Rainer Hedrich
- Lehrstuhl für Botanik I, Julius-Maximilians-Universität Würzburg, 97082 Würzburg, Germany
| | - Tim Rasmussen
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany;
| | - Bettina Böttcher
- Biocenter and Rudolf-Virchow-Zentrum, Universität Würzburg, 97080 Würzburg, Germany;
| |
Collapse
|
5
|
Visualization of the mechanosensitive ion channel MscS under membrane tension. Nature 2021; 590:509-514. [PMID: 33568813 DOI: 10.1038/s41586-021-03196-w] [Citation(s) in RCA: 68] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Accepted: 01/06/2021] [Indexed: 12/20/2022]
Abstract
Mechanosensitive channels sense mechanical forces in cell membranes and underlie many biological sensing processes1-3. However, how exactly they sense mechanical force remains under investigation4. The bacterial mechanosensitive channel of small conductance, MscS, is one of the most extensively studied mechanosensitive channels4-8, but how it is regulated by membrane tension remains unclear, even though the structures are known for its open and closed states9-11. Here we used cryo-electron microscopy to determine the structure of MscS in different membrane environments, including one that mimics a membrane under tension. We present the structures of MscS in the subconducting and desensitized states, and demonstrate that the conformation of MscS in a lipid bilayer in the open state is dynamic. Several associated lipids have distinct roles in MscS mechanosensation. Pore lipids are necessary to prevent ion conduction in the closed state. Gatekeeper lipids stabilize the closed conformation and dissociate with membrane tension, allowing the channel to open. Pocket lipids in a solvent-exposed pocket between subunits are pulled out under sustained tension, allowing the channel to transition to the subconducting state and then to the desensitized state. Our results provide a mechanistic underpinning and expand on the 'force-from-lipids' model for MscS mechanosensation4,11.
Collapse
|
6
|
Discoveries in structure and physiology of mechanically activated ion channels. Nature 2020; 587:567-576. [PMID: 33239794 DOI: 10.1038/s41586-020-2933-1] [Citation(s) in RCA: 295] [Impact Index Per Article: 73.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Accepted: 08/19/2020] [Indexed: 01/24/2023]
Abstract
The ability to sense physical forces is conserved across all organisms. Cells convert mechanical stimuli into electrical or chemical signals via mechanically activated ion channels. In recent years, the identification of new families of mechanosensitive ion channels-such as PIEZO and OSCA/TMEM63 channels-along with surprising insights into well-studied mechanosensitive channels have driven further developments in the mechanotransduction field. Several well-characterized mechanosensory roles such as touch, blood-pressure sensing and hearing are now linked with primary mechanotransducers. Unanticipated roles of mechanical force sensing continue to be uncovered. Furthermore, high-resolution structures representative of nearly every family of mechanically activated channel described so far have underscored their diversity while advancing our understanding of the biophysical mechanisms of pressure sensing. Here we summarize recent discoveries in the physiology and structures of known mechanically activated ion channel families and discuss their implications for understanding the mechanisms of mechanical force sensing.
Collapse
|
7
|
Schlegel AM, Haswell ES. Charged pore-lining residues are required for normal channel kinetics in the eukaryotic mechanosensitive ion channel MSL1. Channels (Austin) 2020; 14:310-325. [PMID: 32988273 PMCID: PMC7757850 DOI: 10.1080/19336950.2020.1818509] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
Mechanosensitive (MS) ion channels are widespread mechanisms for cellular mechanosensation that can be directly activated by increasing membrane tension. The well-studied MscS family of MS ion channels is found in bacteria, archaea, and plants. MscS-Like (MSL)1 is localized to the inner mitochondrial membrane of Arabidopsis thaliana, where it is required for normal mitochondrial responses to oxidative stress. Like Escherichia coli MscS, MSL1 has a pore-lining helix that is kinked. However, in MSL1 this kink is comprised of two charged pore-lining residues, R326 and D327. Using single-channel patch-clamp electrophysiology in E. coli, we show that altering the size and charge of R326 and D327 leads to dramatic changes in channel kinetics. Modest changes in gating pressure were also observed while no effects on channel rectification or conductance were detected. MSL1 channel variants had differing physiological function in E. coli hypoosmotic shock assays, without clear correlation between function and particular channel characteristics. Taken together, these results demonstrate that altering pore-lining residue charge and size disrupts normal channel state stability and gating transitions, and led us to propose the “sweet spot” model. In this model, the transition to the closed state is facilitated by attraction between R326 and D327 and repulsion between R326 residues of neighboring monomers. In the open state, expansion of the channel reduces inter-monomeric repulsion, rendering open state stability influenced mainly by attractive forces. This work provides insight into how unique charge-charge interactions can be combined with an otherwise conserved structural feature to help modulate MS channel function.
Collapse
Affiliation(s)
- Angela M Schlegel
- Department of Biology, Washington University , St. Louis, Missouri, USA.,NSF Center for Engineering Mechanobiology, Washington University , St. Louis, Missouri, USA
| | - Elizabeth S Haswell
- Department of Biology, Washington University , St. Louis, Missouri, USA.,NSF Center for Engineering Mechanobiology, Washington University , St. Louis, Missouri, USA
| |
Collapse
|
8
|
Schlegel AM, Haswell ES. Analyzing plant mechanosensitive ion channels expressed in giant E. coli spheroplasts by single-channel patch-clamp electrophysiology. Methods Cell Biol 2020; 160:61-82. [PMID: 32896333 DOI: 10.1016/bs.mcb.2020.02.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Plants possess numerous ion channels that respond to a range of stimuli, including small molecules, transmembrane voltage, and mechanical force. Many in the latter category, known as mechanosensitive (MS) ion channels, open directly in response to increases in lateral membrane tension. One of the most effective techniques for characterizing ion channel properties is patch-clamp electrophysiology, in which the current through a section of membrane containing ion channels is measured. For MS channels, this technique enables the measurement of key channel properties such as tension sensitivity, conductance, and ion selectivity. These characteristics, along with the phenotypes of genetic mutants, can help reveal the physiological roles of a particular MS channel. In this protocol, we provide detailed instructions on how to study MS ion channels using single-channel patch-clamp electrophysiology in giant E. coli spheroplasts. We first present an optimized method for preparing giant spheroplasts, then describe how to measure MS channel activity using patch-clamp electrophysiology and analyze the resulting data. We also provide recommended equipment lists, setup schematics, and useful conventions.
Collapse
Affiliation(s)
- Angela M Schlegel
- Department of Biology and Center for Engineering Mechanobiology, Washington University in St. Louis, St. Louis, MO, United States
| | - Elizabeth S Haswell
- Department of Biology and Center for Engineering Mechanobiology, Washington University in St. Louis, St. Louis, MO, United States.
| |
Collapse
|
9
|
Structure of the Mechanosensitive Channel MscS Embedded in the Membrane Bilayer. J Mol Biol 2019; 431:3081-3090. [DOI: 10.1016/j.jmb.2019.07.006] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 06/12/2019] [Accepted: 07/01/2019] [Indexed: 12/29/2022]
|
10
|
Gating and inactivation of mechanosensitive channels of small conductance: A continuum mechanics study. J Mech Behav Biomed Mater 2018; 90:502-514. [PMID: 30453114 DOI: 10.1016/j.jmbbm.2018.10.040] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Revised: 04/27/2018] [Accepted: 10/30/2018] [Indexed: 11/21/2022]
Abstract
Mechanosensitive channels of small conductance (MscS) in Escherichia coli (E. coli) serve as a paradigm for understanding the gating behaviors of the MscS family of ion channels. In this work, we develop a continuum mechanics framework to explore the conformational states of MscS during the gating transition. A complete gating transition trajectory from the closed to the open state along with partially open intermediates is obtained, and the open structure is close to the available structural model from crystallographic studies. The computational efficiency of the modeling framework makes it possible to explore the roles of various structural elements (e.g., loops that connect transmembrane helices) and specific interactions in the gating transition. It is observed that removing either the Asp62-Arg131 salt bridge or the Phe68-Leu111 non-polar interaction leads to essentially non-conducting structures even with a membrane tension close to the lysis limit. The loop connecting TM2 (the second transmembrane helix) and TM3 is found to be essential for force transmission during gating, while the loop connecting TM1 and TM2 does not make any major contribution. Based on the different structural evolutions observed when the TM3 kink is treated as a loop or a helical segment, we propose that the helical propensity of the kink plays a central role in inactivation; i.e., under prolonged sub-threshold membrane tension, transition of the initially flexible loop to a helical segment in TM3 may lead to MscS inactivation. Finally, the gating transition of MscS under different transmembrane voltages is explored and found to be essentially voltage independent. Collectively, results from the current continuum mechanics analysis provide further insights into the gating transition of MscS at structural and physical levels, and specific predictions are proposed for further experimental investigations.
Collapse
|
11
|
Wang X, Tang S, Wen X, Hong L, Hong F, Li Y. Transmembrane TM3b of Mechanosensitive Channel MscS Interacts With Cytoplasmic Domain Cyto-Helix. Front Physiol 2018; 9:1389. [PMID: 30327617 PMCID: PMC6174206 DOI: 10.3389/fphys.2018.01389] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 09/12/2018] [Indexed: 11/25/2022] Open
Abstract
The mechanosensitive channel MscS functions as an osmolyte emergency release-valve in the event of a sudden decrease in external environmental osmolarity. MscS has served as a paradigm for studying how channel proteins detect and respond to mechanical stimuli. However, the inter-domain interactions and structural rearrangements that occur in the MscS gating process remain largely unknown. Here, we determined the interactions between the transmembrane domain and cytoplasmic domain of MscS. Using in vivo cellular viability, single-channel electrophysiological recording, and cysteine disulfide trapping, we demonstrated that N117 of the TM3b helix and N167 of the Cyto-helix are critical residues that function at the TM3b-Cyto helix interface. In vivo downshock assays showed that double cysteine substitution at N117 and N167 failed to rescue the osmotic-lysis phenotype of cells in acute osmotic downshock. Single-channel recordings demonstrated that cysteine cross-linking of N117C and N167C led to a non-conductive channel. Consistently, coordination of the histidines of N117H and N167H caused a decrease in channel gating. Moreover, cross-linked N117 and N167 altered the gating of the severe gain-of-function mutant L109S. Our results demonstrate that N117–N167 interactions stabilize the inactivation state by an association of TM3b segments with β-domains of the cytoplasmic region, providing further insights into the gating mechanism of the MscS channel.
Collapse
Affiliation(s)
- Xiaomin Wang
- Children's Hospital and Department of Biophysics, National Health Commission and Chinese Academy of Medical Sciences Key Laboratory of Medical Neurobiology, Zhejiang University School of Medicine, Hangzhou, China
| | - Siyang Tang
- Children's Hospital and Department of Biophysics, National Health Commission and Chinese Academy of Medical Sciences Key Laboratory of Medical Neurobiology, Zhejiang University School of Medicine, Hangzhou, China
| | - Xiaoxu Wen
- Children's Hospital and Department of Biophysics, National Health Commission and Chinese Academy of Medical Sciences Key Laboratory of Medical Neurobiology, Zhejiang University School of Medicine, Hangzhou, China
| | - Lang Hong
- Children's Hospital and Department of Biophysics, National Health Commission and Chinese Academy of Medical Sciences Key Laboratory of Medical Neurobiology, Zhejiang University School of Medicine, Hangzhou, China
| | - Feifan Hong
- Children's Hospital and Department of Biophysics, National Health Commission and Chinese Academy of Medical Sciences Key Laboratory of Medical Neurobiology, Zhejiang University School of Medicine, Hangzhou, China
| | - Yuezhou Li
- Children's Hospital and Department of Biophysics, National Health Commission and Chinese Academy of Medical Sciences Key Laboratory of Medical Neurobiology, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
12
|
Maksaev G, Shoots JM, Ohri S, Haswell ES. Nonpolar residues in the presumptive pore-lining helix of mechanosensitive channel MSL10 influence channel behavior and establish a nonconducting function. PLANT DIRECT 2018; 2:e00059. [PMID: 30506019 PMCID: PMC6261518 DOI: 10.1002/pld3.59] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Mechanosensitive (MS) ion channels provide a universal mechanism for sensing and responding to increased membrane tension. MscS-like (MSL) 10 is a relatively well-studied MS ion channel from Arabidopsis thaliana that is implicated in cell death signaling. The relationship between the amino acid sequence of MSL10 and its conductance, gating tension, and opening and closing kinetics remains unstudied. Here, we identify several nonpolar residues in the presumptive pore-lining transmembrane helix of MSL10 (TM6) that contribute to these basic channel properties. F553 and I554 are essential for wild type channel conductance and the stability of the open state. G556, a glycine residue located at a predicted kink in TM6, is essential for channel conductance. The increased tension sensitivity of MSL10 compared to close homolog MSL8 may be attributed to F563, but other channel characteristics appear to be dictated by more global differences in structure. Finally, MSL10 F553V and MSL10 G556V provided the necessary tools to establish that MSL10's ability to trigger cell death is independent of its ion channel function.
Collapse
Affiliation(s)
- Grigory Maksaev
- Department of Biology and Center for Engineering MechanoBiologyWashington University in Saint LouisSaint LouisMissouri
- Present address:
Department of Cell Biology and Physiology and Center for the Investigation of Membrane Excitability DiseasesWashington University School of MedicineSaint LouisMO
| | - Jennette M. Shoots
- Department of Biology and Center for Engineering MechanoBiologyWashington University in Saint LouisSaint LouisMissouri
| | - Simran Ohri
- Department of Biology and Center for Engineering MechanoBiologyWashington University in Saint LouisSaint LouisMissouri
| | - Elizabeth S. Haswell
- Department of Biology and Center for Engineering MechanoBiologyWashington University in Saint LouisSaint LouisMissouri
| |
Collapse
|
13
|
Identification and Characterization of the Neisseria gonorrhoeae MscS-Like Mechanosensitive Channel. Infect Immun 2018; 86:IAI.00090-18. [PMID: 29581189 DOI: 10.1128/iai.00090-18] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Accepted: 03/15/2018] [Indexed: 12/25/2022] Open
Abstract
Mechanosensitive channels are ubiquitous in bacteria and provide an essential mechanism to survive sudden exposure to a hypo-osmotic environment by the sensing and release of increased turgor pressure. No mechanosensitive channels have thus far been identified and characterized for the human-specific bacterial pathogen Neisseria gonorrhoeae In this study, we identified and characterized the N. gonorrhoeae MscS-like mechanosensitive channel (Ng-MscS). Electrophysiological analyses by the patch clamp method showed that Ng-MscS is stretch activated and contains pressure-dependent gating properties. Further mutagenesis studies of critical residues forming the hydrophobic vapor lock showed that gain-of-function mutations in Ng-MscS inhibited bacterial growth. Subsequent analysis of the function of Ng-MscS in N. gonorrhoeae by osmotic down-shock assays revealed that the survival of Ng-mscS deletion mutants was significantly reduced compared with that of wild-type strains, while down-shock survival was restored upon the ectopic complementation of mscS Finally, to investigate whether Ng-MscS is important for N. gonorrhoeae during infections, competition assays were performed by using a murine vaginal tract infection model. Ng-mscS deletion mutants were outcompeted by N. gonorrhoeae wild-type strains for colonization and survival in this infection model, highlighting that Ng-MscS contributes to in vivo colonization and survival. Therefore, Ng-MscS might be a promising target for the future development of novel antimicrobials.
Collapse
|
14
|
Abstract
Mechanosensitive (MS) channels protect bacteria against hypo-osmotic shock and fulfil additional functions. Hypo-osmotic shock leads to high turgor pressure that can cause cell rupture and death. MS channels open under these conditions and release unspecifically solutes and consequently the turgor pressure. They can recognise the raised pressure via the increased tension in the cell membrane. Currently, a better understanding how MS channels can sense tension on molecular level is developing because the interaction of the lipid bilayer with the channel is being investigated in detail. The MS channel of large conductance (MscL) and of small conductance (MscS) have been distinguished and studied in molecular detail. In addition, larger channels were found that contain a homologous region corresponding to MscS so that MscS represents a family of channels. Often several members of this family are present in a species. The importance of this family is underlined by the fact that members can be found not only in bacteria but also in higher organisms. While MscL and MscS have been studied for years in particular by electrophysiology, mutagenesis, molecular dynamics, X-ray crystallography and other biophysical techniques, only recently more details are emerging about other members of the MscS-family.
Collapse
|
15
|
Lee CP, Maksaev G, Jensen GS, Murcha MW, Wilson ME, Fricker M, Hell R, Haswell ES, Millar AH, Sweetlove LJ. MSL1 is a mechanosensitive ion channel that dissipates mitochondrial membrane potential and maintains redox homeostasis in mitochondria during abiotic stress. THE PLANT JOURNAL : FOR CELL AND MOLECULAR BIOLOGY 2016; 88:809-825. [PMID: 27505616 PMCID: PMC5195915 DOI: 10.1111/tpj.13301] [Citation(s) in RCA: 58] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Revised: 08/04/2016] [Accepted: 08/05/2016] [Indexed: 05/18/2023]
Abstract
Mitochondria must maintain tight control over the electrochemical gradient across their inner membrane to allow ATP synthesis while maintaining a redox-balanced electron transport chain and avoiding excessive reactive oxygen species production. However, there is a scarcity of knowledge about the ion transporters in the inner mitochondrial membrane that contribute to control of membrane potential. We show that loss of MSL1, a member of a family of mechanosensitive ion channels related to the bacterial channel MscS, leads to increased membrane potential of Arabidopsis mitochondria under specific bioenergetic states. We demonstrate that MSL1 localises to the inner mitochondrial membrane. When expressed in Escherichia coli, MSL1 forms a stretch-activated ion channel with a slight preference for anions and provides protection against hypo-osmotic shock. In contrast, loss of MSL1 in Arabidopsis did not prevent swelling of isolated mitochondria in hypo-osmotic conditions. Instead, our data suggest that ion transport by MSL1 leads to dissipation of mitochondrial membrane potential when it becomes too high. The importance of MSL1 function was demonstrated by the observation of a higher oxidation state of the mitochondrial glutathione pool in msl1-1 mutants under moderate heat- and heavy-metal-stress. Furthermore, we show that MSL1 function is not directly implicated in mitochondrial membrane potential pulsing, but is complementary and appears to be important under similar conditions.
Collapse
Affiliation(s)
- Chun Pong Lee
- ARC Centre of Excellence in Plant Energy Biology, University of Western Australia, Bayliss Building M316, 35 Stirling Highway, Crawley, 6009, Western Australia, Australia
| | - Grigory Maksaev
- Department of Biology, Washington University in Saint Louis, One Brookings Drive, Mailcode 1137, Saint Louis, MO, 63130, USA
| | - Gregory S Jensen
- Department of Biology, Washington University in Saint Louis, One Brookings Drive, Mailcode 1137, Saint Louis, MO, 63130, USA
| | - Monika W Murcha
- ARC Centre of Excellence in Plant Energy Biology, University of Western Australia, Bayliss Building M316, 35 Stirling Highway, Crawley, 6009, Western Australia, Australia
| | - Margaret E Wilson
- Department of Biology, Washington University in Saint Louis, One Brookings Drive, Mailcode 1137, Saint Louis, MO, 63130, USA
| | - Mark Fricker
- Department of Plant Sciences, University of Oxford, South Parks Road, Oxford, OX1 3RB, UK
| | - Ruediger Hell
- Department of Plant Molecular Biology, Centre for Organismal Studies, University of Heidelberg, Im Neuenheimer Feld 360, D-69120, Heidelberg, Germany
| | - Elizabeth S Haswell
- Department of Biology, Washington University in Saint Louis, One Brookings Drive, Mailcode 1137, Saint Louis, MO, 63130, USA
| | - A Harvey Millar
- ARC Centre of Excellence in Plant Energy Biology, University of Western Australia, Bayliss Building M316, 35 Stirling Highway, Crawley, 6009, Western Australia, Australia
| | - Lee J Sweetlove
- Department of Plant Sciences, University of Oxford, South Parks Road, Oxford, OX1 3RB, UK
| |
Collapse
|
16
|
Abstract
Escherichia coli and Salmonella encounter osmotic pressure variations in natural environments that include host tissues, food, soil, and water. Osmotic stress causes water to flow into or out of cells, changing their structure, physics, and chemistry in ways that perturb cell functions. E. coli and Salmonella limit osmotically induced water fluxes by accumulating and releasing electrolytes and small organic solutes, some denoted compatible solutes because they accumulate to high levels without disturbing cell functions. Osmotic upshifts inhibit membrane-based energy transduction and macromolecule synthesis while activating existing osmoregulatory systems and specifically inducing osmoregulatory genes. The osmoregulatory response depends on the availability of osmoprotectants (exogenous organic compounds that can be taken up to become compatible solutes). Without osmoprotectants, K+ accumulates with counterion glutamate, and compatible solute trehalose is synthesized. Available osmoprotectants are taken up via transporters ProP, ProU, BetT, and BetU. The resulting compatible solute accumulation attenuates the K+ glutamate response and more effectively restores cell hydration and growth. Osmotic downshifts abruptly increase turgor pressure and strain the cytoplasmic membrane. Mechanosensitive channels like MscS and MscL open to allow nonspecific solute efflux and forestall cell lysis. Research frontiers include (i) the osmoadaptive remodeling of cell structure, (ii) the mechanisms by which osmotic stress alters gene expression, (iii) the mechanisms by which transporters and channels detect and respond to osmotic pressure changes, (iv) the coordination of osmoregulatory programs and selection of available osmoprotectants, and (v) the roles played by osmoregulatory mechanisms as E. coli and Salmonella survive or thrive in their natural environments.
Collapse
|
17
|
Malcolm HR, Blount P. Mutations in a Conserved Domain of E. coli MscS to the Most Conserved Superfamily Residue Leads to Kinetic Changes. PLoS One 2015; 10:e0136756. [PMID: 26340270 PMCID: PMC4560390 DOI: 10.1371/journal.pone.0136756] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Accepted: 08/08/2015] [Indexed: 12/13/2022] Open
Abstract
In Escherichia coli (E. coli) the mechanosensitive channel of small conductance, MscS, gates in response to membrane tension created from acute external hypoosmotic shock, thus rescuing the bacterium from cell lysis. E. coli MscS is the most well studied member of the MscS superfamily of channels, whose members are found throughout the bacterial and plant kingdoms. Homology to the pore lining helix and upper vestibule domain of E. coli MscS is required for inclusion into the superfamily. Although highly conserved, in the second half of the pore lining helix (TM3B), E. coli MscS has five residues significantly different from other members of the superfamily. In superfamilies such as this, it remains unclear why variations within such a homologous region occur: is it tolerance of alternate residues, or does it define functional variance within the superfamily? Point mutations (S114I/T, L118F, A120S, L123F, F127E/K/T) and patch clamp electrophysiology were used to study the effect of changing these residues in E. coli MscS on sensitivity and gating. The data indicate that variation at these locations do not consistently lead to wildtype channel phenotypes, nor do they define large changes in mechanosensation, but often appear to effect changes in the E. coli MscS channel gating kinetics.
Collapse
Affiliation(s)
- Hannah R. Malcolm
- Department of Physiology, University of Texas Southwestern Medical Center, Dallas, Texas, 76390, United States of America
| | - Paul Blount
- Department of Physiology, University of Texas Southwestern Medical Center, Dallas, Texas, 76390, United States of America
- * E-mail:
| |
Collapse
|
18
|
Negative and positive temperature dependence of potassium leak in MscS mutants: Implications for understanding thermosensitive channels. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES 2015; 1848:1678-86. [PMID: 25958301 DOI: 10.1016/j.bbamem.2015.04.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2015] [Revised: 04/24/2015] [Accepted: 04/29/2015] [Indexed: 01/30/2023]
Abstract
Bacterial mechanosensitive channel of small conductance (MscS) is a protein, whose activity is modulated by membrane tension, voltage and cytoplasmic crowding. MscS is a homoheptamer and each monomer consists of three transmembrane helices (TM1-3). Hydrophobic pore of the channel is made of TM3s surrounded by peripheral TM1/2s. MscS gating is a complex process, which involves opening and inactivation in response to the increase of membrane tension. A number of MscS mutants were isolated. Among them mutants affecting gating have been found including gain-of-function (GOF) and loss-of-function (LOF) that open at lower or at higher thresholds, respectively. Previously, using an in vivo screen we isolated multiple MscS mutants that leak potassium and some of them were GOF or LOF. Here we show that for a subset of these mutants K+ leak is negatively (NTD) or positively (PTD) temperature dependent. We show that temperature reliance of these mutants does not depend on how MS gating is affected by a particular mutation. Instead, we argue that NTD or PTD leak is due to the opposite allosteric coupling of the structures that determine the temperature dependence to the channel gate. In PTD mutants an increased hydration of the pore vestibule is directly coupled to the increase in the channel conductance. In NTD mutants, at higher temperatures an increased hydration of peripheral structures leads to complete separation of TM3 and a pore collapse.
Collapse
|
19
|
The mechanosensitive channel of small conductance (MscS) functions as a Jack-in-the box. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES 2014; 1848:159-66. [PMID: 25450806 DOI: 10.1016/j.bbamem.2014.10.022] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2014] [Revised: 10/04/2014] [Accepted: 10/15/2014] [Indexed: 11/23/2022]
Abstract
Phenotypical analysis of the lipid interacting residues in the closed state of the mechanosensitive channel of small conductance (MscS) from Escherichia coli (E. coli) has previously shown that these residues are critical for channel function. In the closed state, mutation of individual hydrophobic lipid lining residues to alanine, thus reducing the hydrophobicity, resulted in phenotypic changes that were observable using in vivo assays. Here, in an analogous set of experiments, we identify eleven residues in the first transmembrane domain of the open state of MscS that interact with the lipid bilayer. Each of these residues was mutated to alanine and leucine to modulate their hydrophobic interaction with the lipid tail-groups in the open state. The effects of these changes on channel function were analyzed using in vivo bacterial assays and patch clamp electrophysiology. Mutant channels were found to be functionally indistinguishable from wildtype MscS. Thus, mutation of open-state lipid interacting residues does not differentially stabilize or destabilize the open, closed, intermediate, or transition states of MscS. Based on these results and other data from the literature, we propose a new gating paradigm for MscS where MscS acts as a "Jack-In-The-Box" with the intrinsic bilayer lateral pressure holding the channel in the closed state. In this model, upon application of extrinsic tension the channel springs into the open state due to relief of the intrinsic lipid bilayer pressure.
Collapse
|
20
|
Martinac B, Nomura T, Chi G, Petrov E, Rohde PR, Battle AR, Foo A, Constantine M, Rothnagel R, Carne S, Deplazes E, Cornell B, Cranfield CG, Hankamer B, Landsberg MJ. Bacterial mechanosensitive channels: models for studying mechanosensory transduction. Antioxid Redox Signal 2014; 20:952-69. [PMID: 23834368 DOI: 10.1089/ars.2013.5471] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
SIGNIFICANCE Sensations of touch and hearing are manifestations of mechanical contact and air pressure acting on touch receptors and hair cells of the inner ear, respectively. In bacteria, osmotic pressure exerts a significant mechanical force on their cellular membrane. Bacteria have evolved mechanosensitive (MS) channels to cope with excessive turgor pressure resulting from a hypo-osmotic shock. MS channel opening allows the expulsion of osmolytes and water, thereby restoring normal cellular turgor and preventing cell lysis. RECENT ADVANCES As biological force-sensing systems, MS channels have been identified as the best examples of membrane proteins coupling molecular dynamics to cellular mechanics. The bacterial MS channel of large conductance (MscL) and MS channel of small conductance (MscS) have been subjected to extensive biophysical, biochemical, genetic, and structural analyses. These studies have established MscL and MscS as model systems for mechanosensory transduction. CRITICAL ISSUES In recent years, MS ion channels in mammalian cells have moved into focus of mechanotransduction research, accompanied by an increased awareness of the role they may play in the pathophysiology of diseases, including cardiac hypertrophy, muscular dystrophy, or Xerocytosis. FUTURE DIRECTIONS A recent exciting development includes the molecular identification of Piezo proteins, which function as nonselective cation channels in mechanosensory transduction associated with senses of touch and pain. Since research on Piezo channels is very young, applying lessons learned from studies of bacterial MS channels to establishing the mechanism by which the Piezo channels are mechanically activated remains one of the future challenges toward a better understanding of the role that MS channels play in mechanobiology.
Collapse
Affiliation(s)
- Boris Martinac
- 1 Molecular Cardiology and Biophysics Division/Mechanosensory Biophysics Laboratory, Victor Chang Cardiac Research Institute , Darlinghurst, Australia
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Cox CD, Wann KT, Martinac B. Selectivity mechanisms in MscS-like channels: From structure to function. Channels (Austin) 2013; 8:5-12. [PMID: 24262975 DOI: 10.4161/chan.27107] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
The E. coli mechanosensitive (MS) channel of small conductance (EcMscS) is the prototype of a diverse family of channels present in all domains of life. While EcMscS has been extensively studied, recent developments show that MscS may display some characteristics not widely conserved in this protein subfamily. With numerous members now electrophysiologically characterized, this subfamily of channels displays a breadth of ion selectivity with both anion and cation selective members. The selectivity of these channels may be relatively weak in comparison to voltage-gated channels but their selectivity mechanisms represent great novelty. Recent studies have identified unexpected residues important for selectivity in these homologs revealing different selectivity mechanisms than those employed by voltage gated K(+), Na(+), Ca(2+) and Cl(-) channels whose selectivity filters are housed within their transmembrane pores. This commentary looks at what is currently known about MscS subfamily selectivity and begins to unravel the potential physiological relevance of these differences.
Collapse
Affiliation(s)
- Charles D Cox
- School of Pharmacy and Pharmaceutical Sciences; Cardiff University; Cardiff, UK; Victor Chang Cardiac Research Institute; Sydney, New South Wales, Australia
| | - Kenneth T Wann
- School of Pharmacy and Pharmaceutical Sciences; Cardiff University; Cardiff, UK
| | - Boris Martinac
- Victor Chang Cardiac Research Institute; Sydney, New South Wales, Australia
| |
Collapse
|
22
|
Wilson ME, Maksaev G, Haswell ES. MscS-like mechanosensitive channels in plants and microbes. Biochemistry 2013; 52:5708-22. [PMID: 23947546 DOI: 10.1021/bi400804z] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The challenge of osmotic stress is something all living organisms must face as a result of environmental dynamics. Over the past three decades, innovative research and cooperation across disciplines have irrefutably established that cells utilize mechanically gated ion channels to release osmolytes and prevent cell lysis during hypoosmotic stress. Early electrophysiological analysis of the inner membrane of Escherichia coli identified the presence of three distinct mechanosensitive activities. The subsequent discoveries of the genes responsible for two of these activities, the mechanosensitive channels of large (MscL) and small (MscS) conductance, led to the identification of two diverse families of mechanosensitive channels. The latter of these two families, the MscS family, consists of members from bacteria, archaea, fungi, and plants. Genetic and electrophysiological analysis of these family members has provided insight into how organisms use mechanosensitive channels for osmotic regulation in response to changing environmental and developmental circumstances. Furthermore, determining the crystal structure of E. coli MscS and several homologues in several conformational states has contributed to our understanding of the gating mechanisms of these channels. Here we summarize our current knowledge of MscS homologues from all three domains of life and address their structure, proposed physiological functions, electrophysiological behaviors, and topological diversity.
Collapse
Affiliation(s)
- Margaret E Wilson
- Department of Biology, Washington University in St. Louis, Missouri 63130, United States
| | | | | |
Collapse
|
23
|
Selectivity mechanism of the mechanosensitive channel MscS revealed by probing channel subconducting states. Nat Commun 2013; 4:2137. [DOI: 10.1038/ncomms3137] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Accepted: 06/12/2013] [Indexed: 11/08/2022] Open
|
24
|
Maksaev G, Haswell ES. Recent characterizations of MscS and its homologs provide insight into the basis of ion selectivity in mechanosensitive channels. Channels (Austin) 2013; 7:215-20. [PMID: 23590902 DOI: 10.4161/chan.24505] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
The bacterial mechanosensitive channel MscS provides an excellent model system for the study of mechanosensitivity and for investigations into the cellular response to hypoosmotic shock. Numerous studies have elucidated the structure, function and gating mechanism of Escherichia coli MscS, providing a wealth of information for the comparative analysis of MscS family members in bacteria, archaea, fungi and plants. We recently reported the electrophysiological characterization of MscS-Like (MSL)10, a MscS homolog from the model flowering plant Arabidopsis thaliana. Here we summarize our results and briefly compare MSL10 to previously described members of the MscS family. Finally, we comment on how this and other recently published studies illuminate the possible mechanisms by which ion selectivity is accomplished in this fascinating family of channels.
Collapse
Affiliation(s)
- Grigory Maksaev
- Department of Biology, Washington University in St. Louis, St. Louis, MO, USA
| | | |
Collapse
|
25
|
Maksaev G, Haswell ES. MscS-Like10 is a stretch-activated ion channel from Arabidopsis thaliana with a preference for anions. Proc Natl Acad Sci U S A 2012; 109:19015-20. [PMID: 23112188 PMCID: PMC3503204 DOI: 10.1073/pnas.1213931109] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Like many other organisms, plants are capable of sensing and responding to mechanical stimuli such as touch, osmotic pressure, and gravity. One mechanism for the perception of force is the activation of mechanosensitive (or stretch-activated) ion channels, and a number of mechanosensitive channel activities have been described in plant membranes. Based on their homology to the bacterial mechanosensitive channel MscS, the 10 MscS-Like (MSL) proteins of Arabidopsis thaliana have been hypothesized to form mechanosensitive channels in plant cell and organelle membranes. However, definitive proof that MSLs form mechanosensitive channels has been lacking. Here we used single-channel patch clamp electrophysiology to show that MSL10 is capable of providing a MS channel activity when heterologously expressed in Xenopus laevis oocytes. This channel had a conductance of ∼100 pS, consistent with the hypothesis that it underlies an activity previously observed in the plasma membrane of plant root cells. We found that MSL10 formed a channel with a moderate preference for anions, which was modulated by strongly positive and negative membrane potentials, and was reversibly inhibited by gadolinium, a known inhibitor of mechanosensitive channels. MSL10 demonstrated asymmetric activation/inactivation kinetics, with the channel closing at substantially lower tensions than channel opening. The electrophysiological characterization of MSL10 reported here provides insight into the evolution of structure and function of this important family of proteins.
Collapse
Affiliation(s)
- Grigory Maksaev
- Department of Biology, Washington University in St. Louis, St. Louis, MO 63130
| | | |
Collapse
|
26
|
Structure and molecular mechanism of an anion-selective mechanosensitive channel of small conductance. Proc Natl Acad Sci U S A 2012; 109:18180-5. [PMID: 23074248 DOI: 10.1073/pnas.1207977109] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Mechanosensitive (MS) channels are universal cellular membrane pores. Bacterial MS channels, as typified by MS channel of small conductance (MscS) from Escherichia coli (EcMscS), release osmolytes under hypoosmotic conditions. MS channels are known to be ion selective to different extents, but the underlying mechanism remains poorly understood. Here we identify an anion-selective MscS channel from Thermoanaerobacter tengcongensis (TtMscS). The structure of TtMscS closely resembles that of EcMscS, but it lacks the large cytoplasmic equatorial portals found in EcMscS. In contrast, the cytoplasmic pore formed by the C-terminal β-barrel of TtMscS is larger than that of EcMscS and has a strikingly different pattern of electrostatic surface potential. Swapping the β-barrel region between TtMscS and EcMscS partially switches the ion selectivity. Our study defines the role of the β-barrel in the ion selection of an anion-selective MscS channel and provides a structural basis for understanding the ion selectivity of MscS channels.
Collapse
|
27
|
Naismith JH, Booth IR. Bacterial mechanosensitive channels--MscS: evolution's solution to creating sensitivity in function. Annu Rev Biophys 2012; 41:157-77. [PMID: 22404681 PMCID: PMC3378650 DOI: 10.1146/annurev-biophys-101211-113227] [Citation(s) in RCA: 77] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The discovery of mechanosensing channels has changed our understanding of bacterial physiology. The mechanosensitive channel of small conductance (MscS) is perhaps the most intensively studied of these channels. MscS has at least two states: closed, which does not allow solutes to exit the cytoplasm, and open, which allows rapid efflux of solvent and solutes. The ability to appropriately open or close the channel (gating) is critical to bacterial survival. We briefly review the science that led to the isolation and identification of MscS. We concentrate on the structure-function relationship of the channel, in particular the structural and biochemical approaches to understanding channel gating. We highlight the troubling discrepancies between the various models developed to understand MscS gating.
Collapse
Affiliation(s)
- James H. Naismith
- Professor Chemical Biology, Biomedical Sciences Research Complex, The North Haugh, The University, St Andrews, Fife KY16 9ST, United Kingdom;
| | - Ian R. Booth
- Professor Emeritus Microbiology, University of Aberdeen, Institute of Medical Sciences, Foresterhill, Aberdeen, AB25 2ZD, United Kingdom;
| |
Collapse
|
28
|
Mechanosensitive channels: what can they do and how do they do it? Structure 2012; 19:1356-69. [PMID: 22000509 DOI: 10.1016/j.str.2011.09.005] [Citation(s) in RCA: 240] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2011] [Revised: 09/19/2011] [Accepted: 09/20/2011] [Indexed: 12/16/2022]
Abstract
While mechanobiological processes employ diverse mechanisms, at their heart are force-induced perturbations in the structure and dynamics of molecules capable of triggering subsequent events. Among the best characterized force-sensing systems are bacterial mechanosensitive channels. These channels reflect an intimate coupling of protein conformation with the mechanics of the surrounding membrane; the membrane serves as an adaptable sensor that responds to an input of applied force and converts it into an output signal, interpreted for the cell by mechanosensitive channels. The cell can exploit this information in a number of ways: ensuring cellular viability in the presence of osmotic stress and perhaps also serving as a signal transducer for membrane tension or other functions. This review focuses on the bacterial mechanosensitive channels of large (MscL) and small (MscS) conductance and their eukaryotic homologs, with an emphasis on the outstanding issues surrounding the function and mechanism of this fascinating class of molecules.
Collapse
|
29
|
Maksaev G, Haswell ES. Expression and characterization of the bacterial mechanosensitive channel MscS in Xenopus laevis oocytes. ACTA ACUST UNITED AC 2011; 138:641-9. [PMID: 22084416 PMCID: PMC3226970 DOI: 10.1085/jgp.201110723] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
We have successfully expressed and characterized mechanosensitive channel of small conductance (MscS) from Escherichia coli in oocytes of the African clawed frog, Xenopus laevis. MscS expressed in oocytes has the same single-channel conductance and voltage dependence as the channel in its native environment. Two hallmarks of MscS activity, the presence of conducting substates at high potentials and reversible adaptation to a sustained stimulus, are also exhibited by oocyte-expressed MscS. In addition to its ease of use, the oocyte system allows the user to work with relatively large patches, which could be an advantage for the visualization of membrane deformation. Furthermore, MscS can now be compared directly to its eukaryotic homologues or to other mechanosensitive channels that are not easily studied in E. coli.
Collapse
Affiliation(s)
- Grigory Maksaev
- Department of Biology, Washington University in Saint Louis, Saint Louis, MO 63130, USA
| | | |
Collapse
|
30
|
Sensing bilayer tension: bacterial mechanosensitive channels and their gating mechanisms. Biochem Soc Trans 2011; 39:733-40. [DOI: 10.1042/bst0390733] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Mechanosensitive channels sense and respond to changes in bilayer tension. In many respects, this is a unique property: the changes in membrane tension gate the channel, leading to the transient formation of open non-selective pores. Pore diameter is also high for the bacterial channels studied, MscS and MscL. Consequently, in cells, gating has severe consequences for energetics and homoeostasis, since membrane depolarization and modification of cytoplasmic ionic composition is an immediate consequence. Protection against disruption of cellular integrity, which is the function of the major channels, provides a strong evolutionary rationale for possession of such disruptive channels. The elegant crystal structures for these channels has opened the way to detailed investigations that combine molecular genetics with electrophysiology and studies of cellular behaviour. In the present article, the focus is primarily on the structure of MscS, the small mechanosensitive channel. The description of the structure is accompanied by discussion of the major sites of channel–lipid interaction and reasoned, but limited, speculation on the potential mechanisms of tension sensing leading to gating.
Collapse
|
31
|
Boer M, Anishkin A, Sukharev S. Adaptive MscS gating in the osmotic permeability response in E. coli: the question of time. Biochemistry 2011; 50:4087-96. [PMID: 21456519 DOI: 10.1021/bi1019435] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Microorganisms adapt to osmotic downshifts by releasing small osmolytes through mechanosensitive (MS) channels. We want to understand how the small mechanosensitive channel's (MscS) activation and inactivation, both driven by membrane tension, optimize survival in varying hypoosmotic shock situations. By measuring light scattering with a stopped-flow device, we estimate bacterial swelling time as 30-50 ms. A partial solute equilibration follows within 150-200 ms, during which optical responses from cells with WT MscS deviate from those lacking MS channels. MscS opening rates estimated in patch clamp show the channels readily respond to tensions below the lytic limit with a time course faster than 20 ms and close promptly upon tension release. To address the role of the tension-insensitive inactivated state in vivo, we applied short, long, and two-step osmotic shock protocols to WT, noninactivating G113A, and fast-inactivating D62N mutants. WT and G113A showed a comparable survival in short 1 min 800 mOsm downshock experiments, but G113A was at a disadvantage under a long 60 min shock. Preshocking cells carrying WT MscS for 15 s to 15 min with a 200 mOsm downshift did not sensitize them to the final 500 mOsm drop in osmolarity of the second step. However, these two-step shocks induced death in D62N more than just a one-step 700 mOsm downshift. We conclude MscS is able to activate and exude osmolytes faster than lytic pressure builds inside the cell under abrupt shock. During prolonged shocks, gradual inactivation prevents continuous channel activity and assists recovery. Slow kinetics of inactivation in WT MscS ensures that mild shocks do not inactivate the entire population, leaving some protection should conditions worsen.
Collapse
Affiliation(s)
- Miriam Boer
- Department of Biology, University of Maryland, College Park, Maryland 20742, United States
| | | | | |
Collapse
|
32
|
Yoshimura K, Sokabe M. Mechanosensitivity of ion channels based on protein-lipid interactions. J R Soc Interface 2010. [PMID: 20356872 DOI: 10.1098/rsif.2010.0095] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Ion channels form a group of membrane proteins that pass ions through a pore beyond the energy barrier of the lipid bilayer. The structure of the transmembrane segment of membrane proteins is influenced by the charges and the hydrophobicity of the surrounding lipids and the pressure on its surface. A mechanosensitive channel is specifically designed to change its conformation in response to changes in the membrane pressure (tension). However, mechanosensitive channels are not the only group that is sensitive to the physical environment of the membrane: voltage-gated channels are also amenable to the lipid environment. In this article, we review the structure and gating mechanisms of the mechanosensitive channels and voltage-gated channels and discuss how their functions are affected by the physical properties of the lipid bilayer.
Collapse
Affiliation(s)
- Kenjiro Yoshimura
- Department of Biology, University of Maryland, College Park, MD 20742, USA
| | | |
Collapse
|
33
|
Yoshimura K, Sokabe M. Mechanosensitivity of ion channels based on protein-lipid interactions. J R Soc Interface 2010; 7 Suppl 3:S307-20. [PMID: 20356872 DOI: 10.1098/rsif.2010.0095.focus] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Ion channels form a group of membrane proteins that pass ions through a pore beyond the energy barrier of the lipid bilayer. The structure of the transmembrane segment of membrane proteins is influenced by the charges and the hydrophobicity of the surrounding lipids and the pressure on its surface. A mechanosensitive channel is specifically designed to change its conformation in response to changes in the membrane pressure (tension). However, mechanosensitive channels are not the only group that is sensitive to the physical environment of the membrane: voltage-gated channels are also amenable to the lipid environment. In this article, we review the structure and gating mechanisms of the mechanosensitive channels and voltage-gated channels and discuss how their functions are affected by the physical properties of the lipid bilayer.
Collapse
Affiliation(s)
- Kenjiro Yoshimura
- Department of Biology, University of Maryland, College Park, MD 20742, USA
| | | |
Collapse
|
34
|
Balleza D, Gómez-Lagunas F. Conserved motifs in mechanosensitive channels MscL and MscS. EUROPEAN BIOPHYSICS JOURNAL: EBJ 2009; 38:1013-27. [PMID: 19424690 DOI: 10.1007/s00249-009-0460-y] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2008] [Revised: 03/27/2009] [Accepted: 04/08/2009] [Indexed: 11/29/2022]
Abstract
Mechanosensitive (MS) channels play a major role in protecting bacterial cells against hypo-osmotic shock. To understand their function, it is important to identify the conserved motifs using sequence analysis methods. In this study, the sequence conservation was investigated by an in silico analysis to generate sequence logos. We have identified new conserved motifs in the domains TM1, TM2 and the cytoplasmic helix from 231 homologs of MS channel of large conductance (MscL). In addition, we have identified new motifs for the TM3 and the cytoplasmic carboxy-terminal domain from 309 homologs of MS channel of small conductance (MscS). We found that the conservation in MscL homologs is high for TM1 and TM2 in the three domains of life. The conservation in MscS homologs is high only for TM3 in Bacteria and Archaea.
Collapse
Affiliation(s)
- Daniel Balleza
- Laboratory of Molecular Biology, University of Wisconsin, 1525 Linden Drive, Madison, WI, 53706, USA.
| | | |
Collapse
|
35
|
Anishkin A, Kamaraju K, Sukharev S. Mechanosensitive channel MscS in the open state: modeling of the transition, explicit simulations, and experimental measurements of conductance. ACTA ACUST UNITED AC 2008; 132:67-83. [PMID: 18591417 PMCID: PMC2442180 DOI: 10.1085/jgp.200810000] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Mechanosensitive channels of small conductance (MscS) are ubiquitous turgor pressure regulators found in many walled cells and some intracellular organelles. Escherichia coli MscS acting as a tension-activated osmolyte release valve shows a nonsaturable conductance (1.2 nS in a 39 mS/cm electrolyte) and weak preference for anions. Pursuing the transition pathways in this channel, we applied the extrapolated motion protocol (cycles of displacements, minimizations, and short simulations) to the previously generated compact resting conformation of MscS. We observed tilting and straightening of the kinked pore-forming TM3 helices during the barrel expansion. Extended all-atom simulations confirmed the stability of the open conformation in the bilayer. A 53° spontaneous axial rotation of TM3s observed after equilibration increased the width and polarity of the pore allowing for stable voltage-independent hydration and presence of both cations and anions throughout the pore. The resultant open state, characterized by a pore 1.6 nm wide, satisfied the experimental conductance and in-plane expansion. Applied transmembrane electric field (±100 to ±200 mV) in simulations produced a flow of both K+ and Cl−, with Cl− current dominating at higher voltages. Electroosmotic water flux strongly correlated with the chloride current (∼8 waters per Cl−). The selectivity and rectification were in agreement with the experimental measurements performed in the same range of voltages. Among the charged residues surrounding the pore, only K169 was found to contribute noticeably in the rectification. We conclude that (a) the barrel expansion involving tilting, straightening, and rotation of TM3s provides the geometry and electrostatics that accounts for the conductive properties of the open pore; (b) the observed regimen of ion passage through the pore is similar to electrodiffusion, thus macroscopic estimations closely approximate the experimental and molecular dynamics-simulated conductances; (c) increased interaction of the opposing ionic fluxes at higher voltages may result in selectivities stronger than measured near the reversal potential.
Collapse
Affiliation(s)
- Andriy Anishkin
- Department of Biology, University of Maryland, College Park, MD 20742, USA
| | | | | |
Collapse
|
36
|
Wang W, Black SS, Edwards MD, Miller S, Morrison EL, Bartlett W, Dong C, Naismith JH, Booth IR. The structure of an open form of an E. coli mechanosensitive channel at 3.45 A resolution. Science 2008; 321:1179-83. [PMID: 18755969 DOI: 10.1126/science.1159262] [Citation(s) in RCA: 165] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
How ion channels are gated to regulate ion flux in and out of cells is the subject of intense interest. The Escherichia coli mechanosensitive channel, MscS, opens to allow rapid ion efflux, relieving the turgor pressure that would otherwise destroy the cell. We present a 3.45 angstrom-resolution structure for the MscS channel in an open conformation. This structure has a pore diameter of approximately 13 angstroms created by substantial rotational rearrangement of the three transmembrane helices. The structure suggests a molecular mechanism that underlies MscS gating and its decay of conductivity during prolonged activation. Support for this mechanism is provided by single-channel analysis of mutants with altered gating characteristics.
Collapse
Affiliation(s)
- Wenjian Wang
- Centre for Biomolecular Sciences, The North Haugh, University of St. Andrews, KY16 9ST, Scotland, UK
| | | | | | | | | | | | | | | | | |
Collapse
|