1
|
Falcon Aguilar M, Ferretti MA, Lins RBE, Silva JDS, Lima DANL, Marchi GM, Baggio Aguiar FH. Effect of Phytic Acid Etching and Airborne-Particle Abrasion Treatment on the Resin Bond Strength. Clin Cosmet Investig Dent 2024; 16:191-199. [PMID: 38835853 PMCID: PMC11149625 DOI: 10.2147/ccide.s456826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Accepted: 05/21/2024] [Indexed: 06/06/2024] Open
Abstract
Objective This study aimed to evaluate the bond strength of a universal adhesive to dentin (μTBS) using different time periods of airborne particle abrasion (APA) and two types of acid etching. Methods Seventy-two human third molars were divided into 9 groups (n=8) according to dentin pretreatment: APA duration (0, 5, or 10s) and acid etching (no acid - NA, 37% phosphoric acid - PhoA, or 1% phytic acid - PhyA). APA was performed at a 0.5 cm distance and air pressure of 60 psi using 50 μm aluminum oxide particles. Afterwards, two coats of Single Bond Universal adhesive (3M) were applied to the dentin surface. Composite blocks were built using the incremental technique, sectioned into 1×1 mm slices and subjected to microtensile bond strength (μTBS) testing. Fracture patterns and surface topography of each dentinal pretreatment were evaluated using a Scanning electron microscope (SEM). Bond strength data were analyzed using two-way ANOVA and Bonferroni post-hoc tests. Results The group that received pretreatment with 5s APA and PhoA presented higher μTBS values among all groups, which was statistically different when compared with the PhoA, 10APA+PhoA, and 5APA+PhyA groups. PhyA did not significantly influence the bond strength of the air-abraded groups. Finally, adhesive failure was considered the predominant failure in all groups. Conclusion Dentin pretreated by airborne particle abrasion using aluminum oxide demonstrated an increase in bond strength when abraded for 5 seconds and conditioned with phosphoric acid in a universal adhesive system.
Collapse
Affiliation(s)
- Milagros Falcon Aguilar
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Marcela Alvarez Ferretti
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | | | | | | | - Giselle Maria Marchi
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | | |
Collapse
|
2
|
BinSaleh S, Sulimany AM, Aldowsari MK, Al-Homaidhi M, Alkuait N, Almashham L, Alghamdi N. Evaluation of the shear bond strength of a tricalcium silicate-based material to four self-adhering glass ionomer materials: an in vitro study. Front Pediatr 2023; 11:1303005. [PMID: 38111624 PMCID: PMC10726004 DOI: 10.3389/fped.2023.1303005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 11/23/2023] [Indexed: 12/20/2023] Open
Abstract
Background This study aimed to evaluate and compare the shear bond strength (SBS) of EQUIA Forte HT with that of other restorative materials, including EQUIA Forte, glass ionomer cement (GIC), and resin-modified glass ionomer cement (RMGIC) when bonded to NeoMTA 2. Materials and methods A total of 120 holes were created in Teflon molds and filled with NeoMTA 2. The restorative materials were immediately applied using customized silicone molds. The samples were randomly divided into two main groups: one to measure the immediate SBS and the other to measure the delayed SBS. These two main groups were further divided into four subgroups based on the restorative material used: EQUIA Forte HT, EQUIA Forte, GIC, and RMGIC. Results The study groups showed statistically significant differences in the mean SBS (p < 0.0001). The immediate SBS of the RMGIC group (mean ± SD: 5.43 ± 1.22) was significantly higher than those of the GIC and EQUIA Forte groups, with no significant difference found compared to the SBS of EQUIA Forte HT. In the delayed SBS, both the RMGIC and EQUIA Forte HT groups (4.98 ± 0.67 and 4.93 ± 0.60, respectively) demonstrated significantly higher bond strengths than the GIC and EQUIA Forte groups (3.81 ± 0.57 and 4.2 ± 0.63, respectively). However, there were no statistically significant differences between the RMGIC and EQUIA Forte HT groups or between the GIC and EQUIA Forte groups. Conclusion Based on our findings, EQUIA Forte HT has shown promising outcomes when used as a restorative material following pulpotomies, with results comparable to those of RMGIC.
Collapse
Affiliation(s)
- Saad BinSaleh
- Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Ayman M. Sulimany
- Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Mannaa K. Aldowsari
- Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Majedah Al-Homaidhi
- Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Nour Alkuait
- College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Lama Almashham
- College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Nada Alghamdi
- College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
3
|
Uçar AY, Kölüş T, Bozkurt DA, Neelakantan P, Ali IAA, Belli S. A laboratory investigation on the effect of biguanide- and pyridine-derived antiseptics on the adhesion of resin composites to dentin. AUST ENDOD J 2023; 49:599-605. [PMID: 37602727 DOI: 10.1111/aej.12791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 08/06/2023] [Accepted: 08/13/2023] [Indexed: 08/22/2023]
Abstract
Optimal bonding of adhesive restorations to dentin is crucial to prevent microleakage and enhance the survival of root-filled teeth. The aim of this study was to investigate the effect of chlorhexidine (CHX), alexidine (ALX) and octenidine dihydrochloride (OCT) on the bond strength of resin composites to coronal dentin. Human coronal dentin specimens were treated with 2% CHX, 0.1% ALX, 0.1% OCT or saline then restored with traditional or bulk-fill resin composites. The adhesion strength between the resin and dentin was measured using the microtensile bond strength and failure mode was determined using a stereomicroscope. Treatment with ALX and OCT resulted in significantly greater μTBS compared with CHX and saline, irrespective of the resin composite used. Alexidine treatment predominantly resulted in mixed failure, while adhesive failures were frequently observed in CHX and saline-treated dentin. In conclusion, final irrigation with ALX or OCT improved the bonding of resin composites to dentin.
Collapse
Affiliation(s)
- Arzu Yağmur Uçar
- Department of Endodontics, Faculty of Dentistry, Selçuk University, Konya, Turkey
| | - Türkay Kölüş
- Department of Restorative Dentistry, Faculty of Dentistry, Karamanoğlu Mehmetbey University Ahmet Keleşoğlu, Karaman, Turkey
| | - D Alperen Bozkurt
- Department of Endodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
| | - Prasanna Neelakantan
- Divison of Restorative Dental Sciences, Discipline of Endodontology, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, Hong Kong
| | - Islam A A Ali
- School of Dentistry, Oregon Health & Science University, Portland, Oregon, USA
| | - Sema Belli
- Department of Endodontics, Faculty of Dentistry, Selçuk University, Konya, Turkey
| |
Collapse
|
4
|
Dos Santos D, Pacheco RR, Komegae GH, da Silva JA, Lima D, Pini N, Sundfeld D. Effects of Hydrofluoric Acid Concentrations, Commercial Brands, and Adhesive Application on the Bond Strength of a Resin Luting Agent to Lithium Disilicate Glass Ceramic. Oper Dent 2023; 48:700-710. [PMID: 37881098 DOI: 10.2341/23-034-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/19/2023] [Indexed: 10/27/2023]
Abstract
OBJECTIVES To evaluate the surface topography/roughness and bond strength of a resin luting agent to a lithium disilicate glass ceramic after etching with different concentrations of hydrofluoric acid (HF) and commercial brands. METHODS For bond strength evaluation, 260 lithium disilicate glass ceramic (EMX) discs were randomly distributed into 13 groups based on concentrations of HF and commercial brands (n=20): 5% and 10%, Lysanda (LY5 and LY10); 5% and 10%, Maquira (MA5 and MA10); 5% and 10%, FGM (FG5 and FG10); 4.8%, Ivoclar Vivadent (IV5); 5% and 10%, PHS do Brasil (PH5 and PH10); 5% and 10%, BM4 (BM5 and BM10); 9%, Ultradent Inc (UL10); and Dentsply (DE10). A further random distribution (n=10) was made based on the application (+) or absence (-) of an adhesive layer. Resin luting agent cylinders (1 mm in diameter) were added on EMX surfaces, light-cured, and stored for 24 hours in deionized water at 37°C. On a universal testing machine (DL 500, EMIC), specimens were submitted to a microshear bond strength test at a crosshead speed of 1 mm/min until failure. A representative etched EMX disc from each group underwent surface topography analysis using field-emission scanning electron microscopy (n=1), and five (n=5) etched EMX discs from each group were tested for surface roughness. Data were statistically analyzed using analysis of variance and Tukey test (α=0.05). RESULTS A less conditioned and smoother surface was observed for 5% HF compared to 10%. Additionally, commercial brands of HF were shown to affect bond strength. When the adhesive layer was not used (-), a 10% concentration promoted higher bond strengths to EMX. However, when adhesive was applied (+), the concentrations of HF and commercial brands had no effect on bond strength results. CONCLUSIONS A 10% concentration of HF results in higher bond strength than a 5% concentration. If an adhesive layer is applied, neither this distinction nor the influence of commercial brands is observed.
Collapse
Affiliation(s)
- Drc Dos Santos
- Diogo Robert Claudino dos Santos, DDS, MSc student, Department of Restorative Dentistry and Prosthodontics, Ingá University Center - UNINGÁ, Maringá, PR, Brazil
| | - R R Pacheco
- Rafael Rocha Pacheco, DDS, MSc, PhD, associate professor, Department of Restorative Sciences, Dental College of Georgia - Augusta University, Augusta, GA, USA
| | - G H Komegae
- Gabriely Hikari Komegae, DDS student, School of Dentistry, Ingá University Center - UNINGÁ, Maringá, PR, Brazil
| | - J A da Silva
- Juliana Andrade da Silva, DDS, MSc, PhD student, Department of Restorative Dentistry, Piracicaba School of Dentistry, University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Danl Lima
- Debora Alves Nunes Leite Lima, DDS, MSc, PhD, professor, Department of Restorative Dentistry, Piracicaba School of Dentistry, University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Nip Pini
- Nubia Inocêncya Pavesi Pini, DDS, MSc, PhD, adjunct professor, Department of Restorative Dentistry and Prosthodontics, Ingá University Center - UNINGÁ, Maringá, PR, Brazil
| | - D Sundfeld
- *Daniel Sundfeld, DDS, MSc, PhD, adjunct professor, Department of Restorative Dentistry and Prosthodontics, Ingá University Center - UNINGÁ, Maringá, PR, Brazil
| |
Collapse
|
5
|
Cardoso GC, Nakanishi L, Isolan CP, Rodrigues CS, Moraes RR. Bonding stability of universal adhesives to feldspathic ceramic with or without prior silane application. J Prosthodont 2023. [PMID: 37771238 DOI: 10.1111/jopr.13775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 09/01/2023] [Accepted: 09/23/2023] [Indexed: 09/30/2023] Open
Abstract
PURPOSE This study aimed to assess the bonding stability of three universal adhesives to a CAD-CAM feldspathic ceramic with or without prior silane application. MATERIALS AND METHODS The universal adhesives tested were Ambar Universal (FGM), Single Bond Universal (3M), and Ybond Universal (Yller). Scotchbond Multipurpose Plus (3M) was used as a control. The silane used was RelyX Ceramic Primer (3M). Microtensile bond strength (μTBS) to Vitablocs Mark II was measured after 24 h or 6 months of water aging (n = 20). Failure modes were observed through scanning electron microscopy, and pH and degree of C=C conversion (DC) of the adhesives were measured (n = 3). Data were analyzed using one-, two-, and three-way ANOVA. RESULTS The pH values differed significantly among the adhesives (p < 0.001), while the DC was similar (p = 0.141). The universal adhesives showed significant differences in μTBS, with higher immediate results when using silane and lower results after aging. Notably, a significant decrease in μTBS was observed after 6 months when silane was applied. In contrast, the control adhesive exhibited consistent results between the 24-h and 6-month storage periods. The universal adhesives showed a decrease in μTBS ranging from 25.5% to 40.1% after prolonged storage. Adhesive failures were predominant in all groups. The presence or absence of silane in the adhesive composition did not affect the bonding performance. CONCLUSIONS The application of a separate silane coupling agent improved the immediate bond strength of universal adhesives to CAD-CAM feldspathic ceramic. However, this bond strength significantly decreased after 6 months of water aging. The bond strength remained stable for universal adhesives when applied without silane after 6 months of aging.
Collapse
Affiliation(s)
- Gabriela C Cardoso
- Graduate Program in Dentistry, Universidade Federal de Pelotas, Pelotas, Brazil
| | - Leina Nakanishi
- Graduate Program in Dentistry, Universidade Federal de Pelotas, Pelotas, Brazil
| | - Cristina P Isolan
- School of Dentistry, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Diamantina, Brazil
| | - Camila S Rodrigues
- Graduate Program in Dentistry, Universidade Federal de Pelotas, Pelotas, Brazil
| | - Rafael R Moraes
- Graduate Program in Dentistry, Universidade Federal de Pelotas, Pelotas, Brazil
| |
Collapse
|
6
|
Arandi NZ. The Classification and Selection of Adhesive Agents; an Overview for the General Dentist. Clin Cosmet Investig Dent 2023; 15:165-180. [PMID: 37692095 PMCID: PMC10488680 DOI: 10.2147/ccide.s425024] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Accepted: 08/23/2023] [Indexed: 09/12/2023] Open
Abstract
Adhesive agents are essential to most restorative procedures used in everyday practice. Depending on the clinical situation, the dentist will choose among a rapidly evolving variety of adhesive agents (bonding agents). Due to the availability of many adhesive agents, appropriate selection can take time and effort. Typically, a practitioner relies more on marketing and experience than in-depth material knowledge. The classification of adhesive agents may need to be clarified and easier to remember due to its lack of relevance to clinical procedures. This paper reviews the published literature retrieved from PubMed, Google Scholar, and Scopus by using specific keywords "adhesive agents", "classification", "dentin", "enamel", "universal", "self-etch", "etch-and-rinse", and "bonding". The titles and abstracts were screened, and the relevant literature was retrieved. The list of references from each identified article was examined to find other potentially relevant articles. Adhesive agents can be classified as etch-and-rinse, self-etch, or "multi-mode" according to their approach to interacting with the smear layer, and each approach can be further classified according to the number of clinical steps required during application. This article reviews the classification of current adhesive agents and discusses the properties that make a specific adhesive agent the optimal choice for a particular clinical indication. The review will assist the general dentist in understanding the various types of available adhesive agents and how they function. Overall, the review will facilitate decision-making and allow the selection of appropriate materials.
Collapse
Affiliation(s)
- Naji Ziad Arandi
- Department of Conservative Dentistry, Faculty of Dentistry, Arab American University, Jenin, Palestine
| |
Collapse
|
7
|
Mancuso E, Durso D, Mazzitelli C, Maravic T, Josic U, D'alessandro C, Generali L, Checchi V, Breschi L, Mazzoni A. Glutaraldehyde-based desensitizers' influence on bonding performances and dentin enzymatic activity of universal adhesives. J Dent 2023; 136:104643. [PMID: 37524197 DOI: 10.1016/j.jdent.2023.104643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 07/27/2023] [Accepted: 07/28/2023] [Indexed: 08/02/2023] Open
Abstract
OBJECTIVES To evaluate the influence of two glutaraldehyde-based desensitizers (L: GLUMA Desensitizer, Heraeus Kulzer and G: GLUMA Desensitizer PowerGel) prior to the adhesive procedures on microtensile bond strength (µTBS) to dentin and endogenous enzymatic activity. METHODS Noncarious human third molars (N = 48) were cut to expose middle coronal dentin. Six experimental groups were formed according to the dentin pre-treatment (L or G) and the universal adhesives (IBU - iBond universal, Kulzer or AU - Adhese Universal, Ivoclar Vivadent) used in the self-etch mode (n = 8): 1) L/IBU; 2) G/IBU; 3) IBU; 4) L/AU; 5) G/AU; 6) AU. Specimens were cut into sticks and stressed until failure after 24 h (T0) or 1 yr of aging (T12). Additional 4 teeth were used for in situ zymography evaluation and data were statistically analyzed (α = 0.05). RESULTS Dentin pre-treatment, adhesive and aging statistically influenced bond strength and enzymatic activity (P<0.001). AU demonstrated higher bond strength values than IBU (P<0.001). The L resulted in higher bond strength compared to the G and control groups (P<0.001). aging statistically influenced bonding performance, especially when no dentin pre-treatment was performed (P<0.001). In situ zymography revealed that at baseline the control groups exhibited lower interfacial fluorescence compared to the experimental groups, irrespective of the adhesive used (P<0,001). However, after 1 yr of artificial storage, no differences were found among the groups (P>0.05). CONCLUSIONS Glutharldeadeyde-based products increased bond strength and determined a stabilization of the adhesive interface over time apparently not related to the MMPs inhibition. CLINICAL SIGNIFICANCE The results of this in vitro study suggest that the application of glutaraldehyde-based desensitizers prior to the adhesive procedures when associated with universal adhesives could result in increased bond strength and stabilization of the adhesive interface over time.
Collapse
Affiliation(s)
- Edoardo Mancuso
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Via San Vitale 59, Bologna 40125, Italy
| | - Diego Durso
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Via San Vitale 59, Bologna 40125, Italy
| | - Claudia Mazzitelli
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Via San Vitale 59, Bologna 40125, Italy
| | - Tatjana Maravic
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Via San Vitale 59, Bologna 40125, Italy
| | - Uros Josic
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Via San Vitale 59, Bologna 40125, Italy
| | - Carlo D'alessandro
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Via San Vitale 59, Bologna 40125, Italy
| | - Luigi Generali
- Department of Surgery, Medicine, Dentistry and Morphological Sciences, Unit of Dentistry and Oral-Maxillo-Facial Surgery, University of Modena and Reggio Emilia, Italy
| | - Vittorio Checchi
- Department of Surgery, Medicine, Dentistry and Morphological Sciences, Unit of Dentistry and Oral-Maxillo-Facial Surgery, University of Modena and Reggio Emilia, Italy
| | - Lorenzo Breschi
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Via San Vitale 59, Bologna 40125, Italy.
| | - Annalisa Mazzoni
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Via San Vitale 59, Bologna 40125, Italy
| |
Collapse
|
8
|
Matos TP, Ñaupari-Villasante R, Kunz PVM, Hass V, Reis A, Gutiérrez MF, Loguercio AD. 48-month clinical evaluation of a copper-containing universal adhesive in non-carious cervical lesions: A double-blind randomised clinical trial. Dent Mater 2023; 39:820-830. [PMID: 37481368 DOI: 10.1016/j.dental.2023.07.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 07/01/2023] [Accepted: 07/02/2023] [Indexed: 07/24/2023]
Abstract
OBJECTIVES This study aimed to evaluate the effect of copper nanoparticles (CuNp) on the clinical performance of a universal adhesive system used as an etch-and-rinse or self-etch strategy. METHODS A total of 216 class V (non-carious lesions) restorations were randomly placed in 36 subjects according to the following groups: ERcu, adhesive in etch-and-rinse with 0.1% CuNp; ERct, adhesive in etch-and-rinse without CuNp; SEcu, adhesive in self-etch with 0.1% CuNp; and Sect, adhesive in self-etch without CuNp. Restorations were evaluated at baseline and at 6, 12, 18, 36, and 48 months, using the FDI and USPHS criteria. Appropriate statistical analyses were performed (α = 0.05). RESULTS After 48 months, 14 restorations were lost (two for ERcu, five for SEcu, and seven for SEct) and the retention rates (95% confidence interval [CI]) were 74.1% for ERcu (95% CI 61.1-83.8); 81.5% for ERct (95% CI 69.2-89.6); 64.8% (95% CI 51.5-76.2) for SEcu; and 64.8% (95% CI 51.5-76.2) for SEct, with statistical differences between SEct vs. ERct and SEcu vs. ERct (p < 0.05). No significant differences between the groups were observed when the secondary parameters were evaluated (p > 0.05). Nineteen restorations (two for ERcu, two for ERct, six for SEcu, and nine for SEct) showed minor marginal staining, and 44 restorations (7 for ERcu, 8 for ERct, 14 for SEcu, and 15 for SEct) presented minimal marginal adaptation defects. SIGNIFICANCE This is the first long-term clinical trial to show that the addition of CuNp to a universal adhesive system does not affect clinical performance.
Collapse
Affiliation(s)
- Thalita P Matos
- School of Dentistry, Tuiuti University, Rua Santo Inácio, 395, Zip Code 82010-210 Curitiba, Santo Inácio, Curitiba, Paraná, Brazil
| | - Romina Ñaupari-Villasante
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Zip Code 84030-900, Campus Uvaranas, Ponta Grossa, Paraná, Brazil
| | - Patrícia Valeria Manozzo Kunz
- School of Dentistry, Tuiuti University, Rua Santo Inácio, 395, Zip Code 82010-210 Curitiba, Santo Inácio, Curitiba, Paraná, Brazil
| | - Viviane Hass
- School of Dentistry, Oral and Craniofacial Sciences, University of Missouri-Kansas City, Kansas City, MO, USA
| | - Alessandra Reis
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Zip Code 84030-900, Campus Uvaranas, Ponta Grossa, Paraná, Brazil
| | - Mario F Gutiérrez
- Universidad de los Andes, Chile, Facultad de Odontología, Santiago Zip Code 7550000, Chile; Physiology Laboratory, Institute for Research in Dental Sciences, University of Chile, Santiago Zip Code 8380544, Chile.
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Zip Code 84030-900, Campus Uvaranas, Ponta Grossa, Paraná, Brazil
| |
Collapse
|
9
|
Yu SY, He X, Tian ZL, Li KX, Chen H, Wang HM, Shi ZS, Zhu S, Cui ZC. Effect of Collagen-Reactive Functional Monomer on Etch-and-Rinse Adhesives. J Dent Res 2023; 102:287-294. [PMID: 36474440 DOI: 10.1177/00220345221134278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
In this study, we evaluated a novel functional monomer (4-formylphenyl acrylate [FA]) that can specifically and covalently bind to the dentin collagen matrix as a potential alternative hydrophobic diluent-like monomer for improving the durability of dentin bonding. Experimental adhesives with different FA contents (0%, 10%, 20%, and 30%) were evaluated as partial substituents for the hydrophilic monomer 2-hydroxyethyl methacrylate, with the commercial adhesive One-Step (Bisco, Inc.) employed as the positive control. Their degree of conversion, viscosity, hydrophobicity, mechanical properties, and water absorption/solubility were measured as the comprehensive characterization. In situ zymographic assays were performed to determine the extent to which FA inhibits the endogenous hydrolytic activity of dentin. Finally, the bonding performances of the novel adhesives were evaluated with microtensile strength tests and scanning electron microscopy. The results showed that the incorporation of FA significantly improved the mobility of experimental adhesives attributable to the dilution property of FA. In contrast to the possible compromised rate of polymerization by hydroxyethyl methacrylate, FA exhibited typical characteristics of favorable copolymerization with polymerizable monomers in adhesives and improved the degree of conversion of experimental adhesives. The rigidity and hydrophobic properties of the phenyl framework of the FA molecule conferred superior mechanical properties and hydrolysis resistance to the novel experimental adhesives. An inhibitory effect on gelatinolytic activities within the hybrid layer was also observed in the in situ zymographic assays, even at a low FA concentration (10%). In conjunction with the significantly improved infiltration found via scanning electron microscopy, the experimental adhesives containing FA possessed significantly better-maintained microtensile strength, even after aging. Thus, the incorporation of this novel monomer endowed the experimental adhesives with multiple enhanced functionalities. These remarkable advantages highlight the suitability of the monomer for further applications in clinical practice.
Collapse
Affiliation(s)
- S Y Yu
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - X He
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - Z L Tian
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - K X Li
- State Key Laboratory of Supramolecular Structures and Materials, College of Chemistry, Jilin University, Changchun, China
| | - H Chen
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - H M Wang
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - Z S Shi
- State Key Laboratory of Supramolecular Structures and Materials, College of Chemistry, Jilin University, Changchun, China
| | - S Zhu
- Department of Prosthetic Dentistry, School and Hospital of Stomatology, Jilin University, Changchun, China
| | - Z C Cui
- State Key Laboratory of Supramolecular Structures and Materials, College of Chemistry, Jilin University, Changchun, China
| |
Collapse
|
10
|
Effect of Silica-Modified Aluminum Oxide Abrasion on Adhesion to Dentin, Using Total-Etch and Self-Etch Systems. Polymers (Basel) 2023; 15:polym15020446. [PMID: 36679326 PMCID: PMC9862807 DOI: 10.3390/polym15020446] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 01/11/2023] [Accepted: 01/12/2023] [Indexed: 01/18/2023] Open
Abstract
This study compared the shear bond strength (SBS) and micromorphology of composite resin to human dentin after pre-treatment with silica-modified aluminum oxide air abrasion. Forty-six molar teeth were treated with either Scotchbond Multi-Purpose (SCMP) or Clearfil SE Bond (CLSE) adhesive. Buccal surfaces were pre-treated with the CoJet air abrasion system (SB), and lingual surfaces were controls. The adhesion of light-cured resin composite to the treated dentin surface was evaluated with SBS. After debonding, substrate surfaces were examined with an optical microscope for failure analysis. In addition, 15 molar teeth were sectioned and randomly assigned to one of five groups, according to the dentin surface pre-treatment and adhesive type, and examined with high-vacuum scanning electron microscopy/energy dispersive X-rays (SEM/EDS). The type of adhesive had a significant effect on SBS (p = 0.000); CLSE had the highest values. SB did not affect SBS (p = 0.090). SEM/EDS revealed residual aluminum and/or silicon on all dentin surfaces after SB, except for the control. Treatment with 32% phosphoric acid in the SCMP adhesive decreased the amounts of aluminum and silicon compared to SB dentin only, whereas CLSE resulted in similar quantities of aluminum and silicon as air-abraded dentin. The results of this study indicate that CLSE might have a higher bond strength to dentin than SCMP. Pre-treatment with SB does not appear to affect bonding strength.
Collapse
|
11
|
Bond Strength Survival of a Novel Calcium Phosphate-Enriched Orthodontic Self-Etching System after Various Ageing Protocols: An In Vitro Study. Int J Dent 2022; 2022:3960362. [PMID: 36624858 PMCID: PMC9825208 DOI: 10.1155/2022/3960362] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 12/07/2022] [Accepted: 12/25/2022] [Indexed: 01/02/2023] Open
Abstract
Objective This study aimed to evaluate the orthodontic bond strength and enamel-preserving ability of a hydroxyapatite nanoparticles-containingself-etch system following exposure to various ageing methods. Materials and Methods Hydroxyapatite nanoparticles (nHAp) were incorporated into an orthodontic self-etch primer (SEP, Transbond™ plus) in three different concentrations (5%, 7%, and 9% wt) and tested versus the plain SEP (control) for shear bond strength (SBS), adhesive remnant index (ARI) scores, and enamel damage in range-finding experiments using premolar teeth. The best-performing formulation was further exposed to the following four artificial ageing methods: initial debonding, 24 h water storage, one-month water storage, and one-month acid challenge. A field-emission scanning electron microscope (FE-SEM) was used to examine the integrity of debonded enamel surfaces and calcium-phosphates (CaPs) reprecipitation. Results The best-performing formulation (7% nHAp-SEP) resulted in significantly lower SBS (p < 0.001) than the control SEP following the four artificial ageing methods. Nevertheless, it survived the ageing protocols and yielded clinically acceptable SBS with the advantages of leaving minimal adhesive residue, preserving enamel integrity and smoothness, and inducing CaP reprecipitation as confirmed by FE-SEM images. Conclusions A newly developed SEP produced adequate orthodontic bond strengths and left unblemished debonded enamel surfaces with minimal remnant adhesive and remineralisation potential, thereby suggesting simpler and safer bonding/debonding procedures.
Collapse
|
12
|
Kadhi H, Winnier J, Ratnaparkhi I. Assessment of microleakage and interfacial adaptation following simultaneous activation technique in primary molars. PEDIATRIC DENTAL JOURNAL 2022. [DOI: 10.1016/j.pdj.2022.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
13
|
Tsujimoto A, Barkmeier WW, Teixeira EC, Takamizawa T, Miyazaki M, Latta MA. Fatigue bond strength of dental adhesive systems: Historical background of test methodology, clinical considerations and future perspectives. JAPANESE DENTAL SCIENCE REVIEW 2022; 58:193-207. [PMID: 35789771 PMCID: PMC9250030 DOI: 10.1016/j.jdsr.2022.05.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 01/27/2022] [Accepted: 05/09/2022] [Indexed: 10/31/2022] Open
|
14
|
Sun Z, You X, Xu J, Chen L, Li S, Zhang Z, Guo L. Effectiveness of sodium hypochlorite treatment on the bonding of four adhesive systems to fluorotic enamel. Dent Mater J 2022; 41:660-667. [PMID: 35584935 DOI: 10.4012/dmj.2021-305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The study evaluated the effect of sodium hypochlorite (NaOCl) treatment on fluorotic enamel bonding of four adhesive systems. They were Single Bond 2 (SB2), Prime&Bond NT (PBN), Clearfil SE Bond (CSB), and Single Bond Universal (SBU). One hundred eighteen extracted moderate fluorotic molars were divided into eight groups according to NaOCl pretreatment and four adhesive systems. The microshear bond strength (μSBS), etching pattern, and penetration depth (PD) were observed. The statistical method was two-way ANOVA and least significant difference (LSD) test (α=0.05). The application of NaOCl significantly increased the μSBS of PBN and SBU (p<0.05). The enamel-etching pattern of CSB and SBU was deeper under SEM. A noticeable increase of PD was in SB2 and SBU after the application of NaOCl (p<0.05). Pretreatment of 5.25% NaOCl for the 60 s can increase μSBS of PBN and SBU, PD of SB2 and SBU, and improve enamel-etching pattern of CSB and SBU to fluorotic enamel.
Collapse
Affiliation(s)
- Zhengfan Sun
- Department of Prosthodontics, Graduate School of Stomatology Southwest Medical University
| | - Xiaoxiao You
- Department of Prosthodontics, Graduate School of Stomatology Southwest Medical University
| | - Jie Xu
- Department of Prosthodontics, Graduate School of Stomatology Southwest Medical University
| | - Long Chen
- Department of Prosthodontics, Graduate School of Stomatology Southwest Medical University
| | - Sihui Li
- Department of Prosthodontics, Graduate School of Stomatology Southwest Medical University
| | - Zhenghao Zhang
- Department of Prosthodontics, Graduate School of Stomatology Southwest Medical University
| | - Ling Guo
- Department of Prosthodontics, Hospital of Stomatology Affiliated to Southwest Medical University
| |
Collapse
|
15
|
Weerakoon AT, Cooper C, Sokolowski KA, Meyers IA, Thomson D, Ford PJ, Sexton C, Symons AL. Effect of dentine site on resin and cement adaptation tested using X-ray and electron microscopy to evaluate bond durability and adhesive interfaces. Eur J Oral Sci 2022; 130:e12890. [PMID: 35959863 DOI: 10.1111/eos.12890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 07/18/2022] [Indexed: 01/07/2023]
Abstract
Glass ionomer (GI) cements and self-etch (SE) or universal adhesives after etching (ER) adapt variably with dentine. Dentine characteristics vary with depth (deep/shallow), location (central/peripheral), and microscopic site (intertubular/peritubular). To directly compare adhesion to dentine, non-destructive imaging and testing are required. Here, GI, ER, and SE adapted at different dentine depths, locations, and sites were investigated using micro-CT, xenon plasma focused ion beam scanning electron microscopy (Xe PFIB-SEM), and energy dispersive X-ray spectroscopy (EDS). Extracted molars were prepared to deep or shallow slices and treated with the three adhesives. Micro-CT was used to compare changes to air volume gaps, following thermocycling, and statistically analysed using a quantile regression model and Fisher's exact test. The three adhesives performed similarly across dentine depths and locations, yet no change or overall increases and decreases in gaps at all dentine depths and locations were measured. The Xe PFIB-SEM-milled dentine-adhesive interfaces facilitated high-resolution characterization, and element profiling revealed variations across the tooth-material interfaces. Dentine depth and location had no impact on adhesive durability, although microscopic differences were observed. Here we demonstrate how micro-CT and Xe PFIB-SEM can be used to compare variable dental materials without complex multi-stage specimen preparation to minimize artefacts.
Collapse
Affiliation(s)
| | - Crystal Cooper
- Institute for Future Environments, Central Analytical Research Facility, Queensland University of Technology, Brisbane, Queensland, Australia.,Centre for Microscopy, Characterisation, and Analysis, The University of Western Australia, Perth, Western Australia, Australia
| | | | - Ian Arthur Meyers
- School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
| | - David Thomson
- School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
| | - Pauline Jane Ford
- School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
| | - Christopher Sexton
- School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
| | - Anne Louise Symons
- School of Dentistry, The University of Queensland, Brisbane, Queensland, Australia
| |
Collapse
|
16
|
Bellan MC, da Cunha P, Colombino A, Bittencourt HR, Mota EG, Borges GA, Spohr AM. Retention of Manually or CAD/CAM-customized Fiberglass Posts Luted to Enlarged Root Canals with Different Resin Cements. Oper Dent 2022; 47:449-460. [PMID: 35917252 DOI: 10.2341/21-094-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/06/2021] [Indexed: 11/23/2022]
Abstract
The aim of this laboratory study was to evaluate the pull-out force of a prefabricated fiberglass post (PP), relined fiberglass post (RP), or milled fiberglass post (MP) luted with Multilink N (MN), RelyX Unicem 2 (RXU2) or RelyX Ultimate (RU) to enlarged root canals. The thickness of the resin cements and the presence of voids in the resin cement film were observed. The root canals of 90 bovine incisors were enlarged, endodontically treated, and randomly divided into 9 groups (n=10) according to the post type and resin cement. The specimens were scanned using micro-CT to analyze the thickness of the resin cement and the presence of voids. The specimens were submitted to mechanical cyclic loading (500,000 cycles at 50 N load) and subjected to pull-out force testing. Two-way ANOVA and Tukey's test analyzed the pull-out force and resin cement thickness data. Kruskal-Wallis and Bonferroni tests analyzed the void scores. The interaction between factors (post x resin cement) was significant (p=0.0001) for the pull-out force. Higher pull-out forces were obtained for RP and MP compared to PP. The post factor was significant (p=0.0001) for resin cement thickness, which was higher for PP (1054 μm), followed by MP (301 μm) and RP (194 μm). More void formation occurred for PP, being less for RP, differing significantly among the posts. Post customization (RP and MP) decreased resin cement thickness and void formation, favoring a higher pull-out force. Resin cements requiring an adhesive application (MN and RU) favored higher pull-out force than self-adhesive resin cement (RXU2).
Collapse
Affiliation(s)
- M C Bellan
- Mariá Cortina Bellan, DDS, MS, PhD, Department of Restorative Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| | - Pfjs da Cunha
- Patrícia Fernandes Jerzewski Sotero da Cunha, DDS, MsC, Private Practice, Porto, Alegre, Brazil
| | - Acl Colombino
- Ana Caroline Lima Colombino, DDS, Department of Restorative Dentistry, Uberaba University,Uberaba, Brazil
| | - H R Bittencourt
- Hélio Radke Bittencourt, MsC, PhD, Polytechnic School, Pontifical Catholic of Rio Grande do Sul, Porto Alegre, Brazil
| | - E G Mota
- Eduardo Gonçalves Mota, DDS, MS, PhD, Department of Restorative Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil
| | - G A Borges
- Gilberto Antonio Borges, DDS, MS, PhD, Department of Restorative Dentistry, School of Dentistry, Uberaba University, Uberaba, Brazil
| | - A M Spohr
- *Ana Maria Spohr, DDS, MS, PhD, Pontifical Catholic University of Rio Grande do Sul Porto Alegre, Rio Grande do Sul, Brazil
| |
Collapse
|
17
|
Fazelian N, Rahimi Dashtaki A, Eftekharian M, Amiri B. Influence of chlorhexidine 2% and sodium hypochlorite 5.25% on micro-tensile bond strength of universal adhesive system (G-Premio Bond). BRAZILIAN JOURNAL OF ORAL SCIENCES 2022. [DOI: 10.20396/bjos.v21i00.8667932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
Aim: One of the reasons for the failure of adhesion in composite restorations and secondary caries may be the chemical irrigants used during the endodontic treatment. NaOCl is widely used for the biomechanical preparation of root canals due to its antimicrobial properties and capacity to dissolve organic material. In addition, another very effective decontamination solution is chlorhexidine 2%. There are few studies about the effect of root canal irrigation solutions on bond strength of universal adhesives therefore, in this study we have investigated the influence of CHX 2% and NaOCl 5.25% on micro-tensile bond strength of G-Premio Bond. Methods: Twenty-four human teeth were randomly allocated to the following groups: G1, immersion in saline solution 0.9% for 30 minutes (control); G2, immersion in CHX 2% for 30 minutes; G3, immersion in NaOCl 5.25% for 30 minutes. After restoration, the dentin/resin interface was tested by micro-tensile bond strength. The surfaces morphology was analyzed by Scanning Electron Microscopy. Data were analyzed by ANOVA followed by Tukey test in SPSS software Version 24. Results: There was a statistically significant difference between G3 and G1 (P < 0.05). There were no statistically significant differences among G1 and G2, G2 and G3. Conclusion: Root canal irrigation with NaOCl 5.25% significantly reduced the micro-tensile bond strength in the G-Premio Bond at self-etch mode, but the use of CHX did not make a significant difference.
Collapse
|
18
|
Comparative Evaluation of Microleakage of Flowable Composite Resin Using Etch and Rinse, Self-Etch Adhesive Systems, and Self-Adhesive Flowable Composite Resin in Class V Cavities: Confocal Laser Microscopic Study. MATERIALS 2022; 15:ma15144963. [PMID: 35888429 PMCID: PMC9319247 DOI: 10.3390/ma15144963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/14/2022] [Accepted: 07/14/2022] [Indexed: 12/10/2022]
Abstract
The essential factor in determining the preservation of restoration is the marginal seal. Restoring cervical lesions with a resin composite has always been a challenge. Composite resins with various viscosities and different bonding systems are being researched to reduce the microleakage. Confocal laser scanning microscopy (CLSM) is the latest non-destructive technique for visualizing the microleakage. Objectives: To evaluate and compare the microleakage of Universal Flo composite resin (G-aenial) using etch and rinse adhesive system ER-2 steps (Adper Single Bond 2), self-etch adhesive system SE-1 step (G-Bond), and self-adhesive flowable composite resin (Constic) in Class V cavities using a confocal laser scanning microscope. Materials and Method: Class V cavities were prepared on 27 caries-free human extracted premolar teeth on the buccal and lingual surfaces with standardized dimensions of 2 mm height, width 4 mm, and a depth of 2 mm. After the cavity preparation, all teeth were randomly divided into three groups, namely Group-I: G-aenial Universal Flo with Single Bond 2 (n = 9 teeth); Group-II: G- aenial Universal Flo with G-Bond (n = 9 teeth), and Group-III: Constic (n = 9 teeth). The prepared and restored specimens were then subjected to thermocycling for 500 cycles in a water bath at 5 °C and 55 °C with a dwelling time of 30 s. The specimens were placed in 0.6% aqueous rhodamine dye for 48 h. Sectioning was carried out bucco-lingually and specimens were evaluated for microleakage under a confocal laser scanning microscope. Results: There was a significant difference (p = 0.009) in microleakage when comparing total etch and rinse, specifically between Adper Single Bond 2 ER-2 steps (fifth generation) and self-adhesive flowable composite resin, which is Constic. There was more microleakage in the self-etch bonding agent, particularly G-Bond, SE-1 step (seventh generation), when compared to ER-2 steps (fifth generation bonding agent); however, the results were not statistically significant (p = 0.468). The self-adhesive flowable composite resin showed more microleakage than SE-1 step and ER-2 steps. Conclusions: None of the adhesive systems tested were free from microleakage. However, less microleakage was observed in the total etch and rinse, especially Adper Single Bond 2 (ER-2 steps), than the self-etch adhesive system SE-1 step and self-adhesive flowable composite resin. Clinical significance: Constant research and technological advancements are taking place in dentin adhesives to improve the marginal seal. This has led to the evolution of total acid-etching dentin bonding agents termed as etch and rinse (ER)-2 steps (fifth generation dentin bonding agents) and self-etching (SE) 2 steps, and SE-1 step dentin bonding agents termed as the sixth and seventh generation bonding agents, respectively.
Collapse
|
19
|
Rey YCD, Palma-Dibb RG, França R, Paula-Silva FWG, Guedes DFC, Fiuza C, Fernandes ACBCJ, Faraoni JJ, Roselino LMR. Phosphoric acid containing proanthocyanidin enhances bond stability of resin/dentin interface. Braz Dent J 2022; 33:62-70. [PMID: 36043570 DOI: 10.1590/0103-6440202203941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 02/27/2021] [Indexed: 11/22/2022] Open
Abstract
Proanthocyanidin (PA) is a promising dentin biomodifier due to its ability to stabilize collagen fibrils against degradation by matrix metalloproteinases (MMPs); however, the most effective protocol to incorporate PA into bonding procedures is still unclear. This study evaluated the effect of dentin biomodification with a PA acid etchant on MMP activity, adhesive interface morphology and resin-dentin microtensile bond strength. Sound extracted human molars were flattened to expose dentin and acid-etched for 15 s according to the groups: EXP - experimental phosphoric acid; EXP+PA - experimental phosphoric acid 10% PA; TE - total-etching system; SE - self-etching system. Samples were restored with composite resin and stored in distilled water (37ºC). MMP activity and interface morphology were analyzed after 24 h by in situ zymography (n=6) and scanning electron microscopy (n=3), respectively. The resin-dentin microtensile bond strength (μTBS) was evaluated after 24 h and 6 months storage (n=6). Significantly higher MMP activity was detected in etched dentin compared with untreated dentin (p<0.05), but no difference among acid groups was found. Resin tags and microtags, indicative of proper adhesive system penetration in dentinal tubules and microtubules, were observed along the hybrid layer in all groups. There was no difference in μTBS between 24 h and 6 months for EXP+PA; moreover, it showed higher long-term μTBS compared with TE and EXP (p<0.05). The results suggest that 15 s of biomodification was not sufficient to significantly reduce MMP activity; nonetheless, EXP+PA was still able to improve resin-dentin bond stability compared with total- and self-etching commercial systems.
Collapse
Affiliation(s)
- Yumi C Del Rey
- Departmento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil
| | - Regina G Palma-Dibb
- Departmento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil
| | - Rodrigo França
- Department of Restorative Dentistry, Faculty of Dentistry, University of Manitoba, Winnipeg, MB, Canada
| | - Francisco W G Paula-Silva
- Departmento de Clínica Infantil, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil
| | - Débora F C Guedes
- Departmento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil
| | - Cristina Fiuza
- Department of Restorative Dentistry, Faculty of Dentistry, University of Manitoba, Winnipeg, MB, Canada
| | - Ana C B C J Fernandes
- Department of Oral Biology, Faculty of Dentistry, University of Manitoba, Winnipeg, MB, Canada
| | - Juliana J Faraoni
- Departmento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil
| | - Lourenço M R Roselino
- Departmento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil
| |
Collapse
|
20
|
Vermelho PM, Freitas PM, Reis AF, Giannini M. Influence of Er:YAG laser irradiation settings on dentin-adhesive interfacial ultramorphology and dentin bond strength. Microsc Res Tech 2022; 85:2943-2952. [PMID: 35557015 DOI: 10.1002/jemt.24144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 04/19/2022] [Accepted: 04/25/2022] [Indexed: 11/07/2022]
Abstract
This study evaluated the effects of Erbium-doped yttrium aluminium garnet (Er:YAG) laser settings and dentin bonding agents on ultramorphological characteristics of resin-laser-irradiated dentin interfaces and dentin bond strength (BS) of these adhesive systems. Additionally, dentin depth affected by Er:YAG laser irradiations was measured. The experiments were performed on occlusal dentin surfaces of third molars that were flattened with 600-grit SiC sandpaper. Treated-dentin with laser settings (250 mJ/4 Hz and 160 mJ/10 Hz) were the experimental groups, while SiC abraded dentin was the control. These three dentin treatments and three adhesives (two self-etchings and one etch-&-rinse adhesive) formed nine groups for the ultramorphology of laser-ablated dentin-adhesives interfacial analysis, using a transmission electron microscope (TEM). For BS (n = 8), the same nine groups were tested with addition of the two evaluation times (24 h after sample preparation or 1 year). The depths of Er:YAG laser effects into the dentin were measured using a TEM (n = 10). Ablated-dentin depth and BS data were analyzed by one- and three-way ANOVA, respectively, and Tukey's test (α = 0.05). Hybrid layer formation was only observed for controls, while for laser-treated dentin, adhesives were bonded to dentin with resin tags formation. Laser settings reduced the BS for all adhesives at 24 h, while at 1 year, etch-&-rinse adhesive presented the highest BS, regardless treatment (control or laser settings). Dentin depth affected by laser settings was similar. The laser irradiation altered the bonding mechanism of the adhesives to dentin and reduced the BS for self-etching adhesives. Etch-&-rinse adhesive yielded the highest BS at 1 year. Laser settings similarly affected the dentin in depth.
Collapse
Affiliation(s)
- Paulo Moreira Vermelho
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| | - Patricia Moreira Freitas
- Department of Operative Dentistry, School of Dentistry, University of São Paulo, São Paulo, São Paulo, Brazil
| | - André Figueiredo Reis
- Department of Restorative Dental Sciences, College of Dentistry, University of Florida, Gainesville, Florida, USA
| | - Marcelo Giannini
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil
| |
Collapse
|
21
|
Zheng H, Shi Y, Bi L, Zhang Z, Zhou Z, Shao C, Cui D, Cheng X, Tang R, Pan H, Wu Z, Fu B. Dual Functions of MDP Monomer with De- and Remineralizing Ability. J Dent Res 2022; 101:1172-1180. [PMID: 35450492 DOI: 10.1177/00220345221088214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Methacryloyloxydecyl dihydrogen phosphate (MDP) has been speculated to induce mineralization, but there has been no convincing evidence of its ability to induce intrafibrillar mineralization. Polymers play a critical role in biomimetic mineralization as stabilizers/inducers of amorphous precursors. Hence, MDP-induced biomimetic mineralization without polymer additives has not been fully verified or elucidated. By combining 3-dimensional stochastic optical reconstruction microscopy, surface zeta potentials, contact angle measurements, inductively coupled plasma-optical emission spectroscopy, transmission electron microscopy, atomic force microscopy, and Fourier transform infrared spectroscopy with circular dichroism, we show that amphiphilic MDP can not only demineralize dentin by releasing protons as an acidic functional monomer but also infiltrate collagen fibrils (including dentin collagen), unwind the triple helical structure by breaking hydrogen bonds, and finally immobilize within collagen. MDP-bound collagen functions as a huge collagenous phosphoprotein (HCPP), in contrast to chemical phosphorylation modifications. HCPP can induce biomimetic mineralization itself without polymer additives by alternatively attracting calcium and phosphate through electrostatic attraction. Therefore, we herein propose the dual functions of amphiphilic MDP monomer with de- and remineralizing ability. MDP in the free state can demineralize dentin substrates by releasing protons, whereas MDP in the collagen-bound state as HCPP can induce intrafibrillar mineralization. The dual functions of MDP monomer with de- and remineralization properties might create a new epoch in adhesive dentistry and preventive dentistry.
Collapse
Affiliation(s)
- H Zheng
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Hangzhou, Zhejiang Province, China
| | - Y Shi
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Hangzhou, Zhejiang Province, China
| | - L Bi
- The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang Province, China
| | - Z Zhang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Hangzhou, Zhejiang Province, China
| | - Z Zhou
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Hangzhou, Zhejiang Province, China
| | - C Shao
- Center for Craniofacial Molecular Biology, University of Southern California, Los Angeles, CA, USA
| | - D Cui
- Institute of Advanced Synthesis, School of Chemistry and Molecular Engineering, Jiangsu National Synergetic Innovation Center for Advanced Materials, Nanjing Tech University (Nanjing Tech), Nanjing, Jiangsu Province, China
| | - X Cheng
- Institute of Advanced Synthesis, School of Chemistry and Molecular Engineering, Jiangsu National Synergetic Innovation Center for Advanced Materials, Nanjing Tech University (Nanjing Tech), Nanjing, Jiangsu Province, China
| | - R Tang
- Center for Biomaterials and Biopathways, Department of Chemistry, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - H Pan
- Qiushi Academy for Advanced Studies, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Z Wu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Hangzhou, Zhejiang Province, China
| | - B Fu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Hangzhou, Zhejiang Province, China
| |
Collapse
|
22
|
The effect of fluoride iontophoresis on seal ability of self-etch adhesive in human dentin in vitro. BMC Oral Health 2022; 22:109. [PMID: 35366856 PMCID: PMC8976950 DOI: 10.1186/s12903-022-02146-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Accepted: 03/25/2022] [Indexed: 11/22/2022] Open
Abstract
Background Fluoride iontophoresis (FI) is a non-invasive method for the transfer of fluoride ions under electrical pressure into dental hard tissue. This study aimed to determine the effect of FI on the seal ability of self-etch adhesive in human dentin using dentin permeability test and scanning electron microscopy (SEM). Methods The experiments were divided into 2 series: series 1 was performed on 28 extracted intact third molars and series 2 was performed on 28 extracted carious third molars (ICDAS 4 and 5). In each series, 20 teeth were used for dentin permeability test and 8 teeth were used for SEM study. For dentin permeability test, the specimens were divided into dentin without FI (control) and dentin with FI (experimental) subgroups. Hydraulic conductance (HD) of dentin was measured before and after adhesive treatment, and calculated for the percentage decrease of HD in each subgroup. Two-way ANOVA and Tukey test were used for statistical analysis. SEM study was used to assess the seal ability of self-etch adhesive and penetration of fluoride ions into dentinal tubules. Results HD after self-etch adhesive treatment reduced by 57.75 ± 17.99% in intact dentin with FI, 46.60 ± 17.03% in intact dentin without FI, 45.00 ± 15.30% in caries affected dentin without FI, and 37.28 ± 14.72% in caries affected dentin with FI. There was no significant difference in percentage decrease of HD between dentin without FI and dentin with FI (P = 0.742); meanwhile, intact dentin with FI had significant greater percentage decrease than caries affected dentin with FI (P < 0.05). SEM findings showed FI produced more particle formation and deeper precipitation in intact dentin than those in caries affected dentin. Conclusions FI did not affect the seal ability of self-etch adhesive in human dentin when compared to without FI. However, FI could augment the seal ability of the self-etch adhesive in intact dentin better than that in caries affected dentin. Supplementary Information The online version contains supplementary material available at 10.1186/s12903-022-02146-w.
Collapse
|
23
|
Hardan L, Orsini G, Bourgi R, Cuevas-Suárez CE, Nicastro M, Lazarescu F, Filtchev D, Cornejo-Ríos E, Zamarripa-Calderón JE, Sokolowski K, Lukomska-Szymanska M. Effect of Active Bonding Application after Selective Dentin Etching on the Immediate and Long-Term Bond Strength of Two Universal Adhesives to Dentin. Polymers (Basel) 2022; 14:polym14061129. [PMID: 35335459 PMCID: PMC8951477 DOI: 10.3390/polym14061129] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/01/2022] [Accepted: 03/08/2022] [Indexed: 02/01/2023] Open
Abstract
The objective was to evaluate the influence of active bonding applications (ABA) for different time intervals after selective dentin etching (SDE) for 3 s on the microtensile bond strength (μTBS) to dentin of two universal adhesive systems (UAs): one containing 2-hydroxyethyl methacrylate (HEMA) (Scotchbond Universal, SBU), and one that was HEMA-free (Prime&Bond Universal, PBU). Dentin bovine specimens were divided into four groups: self-etch as control (SE), SDE + ABA for 15 s (SDE15), SDE + ABA for 20 s (SDE20), and SDE + ABA for 25 s (SDE25). The μTBS test was performed after a water storage of 24 h and 6 months. Scanning electron microscopy (SEM) was used in order to examine the resin−dentin interface. For the PBU, the µTBS was significantly influenced only by the aging factor (p < 0.026). A statistically significant decrease in the µTBS after 6 months of aging was observed only for the SDE15 group. For SBU, µTBS was significantly influenced by the protocol application and the aging time (p ≤ 0.041). The groups SDE15, SDE20, and SDE25 achieved statistically significant higher values (after 24 h and 6 months). No considerable variances were noticed in the homogeneity and continuity of the hybrid layer (HL) among the groups. In conclusion, SDE and ABA improved the µTBS only of a HEMA-containing universal adhesive.
Collapse
Affiliation(s)
- Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (L.H.); (R.B.)
| | - Giovana Orsini
- Department of Clinical Sciences and Stomatology, School of Medicine, Polytechnic University of Marche, Via Tronto 10, 60126 Ancona, Italy;
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (L.H.); (R.B.)
| | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, Circuito Ex Hacienda La Concepción S/N, San Agustín Tlaxiaca 42160, Hidalgo, Mexico; (E.C.-R.); (J.E.Z.-C.)
- Correspondence: (C.E.C.-S.); (M.L.-S.); Tel.: +52-(771)-7-2000 (C.E.C.-S.); +48-42-675-74-61 (M.L.-S.)
| | - Marco Nicastro
- Private Practice, “Studio Nicastro” Dental Clinic, Corso Trieste 142, 00198 Roma, Italy;
| | - Florin Lazarescu
- Private Practice, “Trident” Dental Clinic and Postgraduate Course Centre, Street Dr. Louis Pasteur 1A, 050533 Bucharest, Romania;
| | - Dimitar Filtchev
- Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University of Sofia, 1000 Sofia, Bulgaria;
| | - Elizabeth Cornejo-Ríos
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, Circuito Ex Hacienda La Concepción S/N, San Agustín Tlaxiaca 42160, Hidalgo, Mexico; (E.C.-R.); (J.E.Z.-C.)
| | - Juan Eliezer Zamarripa-Calderón
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, Circuito Ex Hacienda La Concepción S/N, San Agustín Tlaxiaca 42160, Hidalgo, Mexico; (E.C.-R.); (J.E.Z.-C.)
| | - Krzysztof Sokolowski
- Department of Restorative Dentistry, Medical University of Lodz, 251 Pomorska Street, 92-213 Lodz, Poland;
| | - Monika Lukomska-Szymanska
- Department of General Dentistry, Medical University of Lodz, 251 Pomorska Street, 92-213 Lodz, Poland
- Correspondence: (C.E.C.-S.); (M.L.-S.); Tel.: +52-(771)-7-2000 (C.E.C.-S.); +48-42-675-74-61 (M.L.-S.)
| |
Collapse
|
24
|
Bonding interface and dentin enzymatic activity of two universal adhesives applied following different etching approaches. Dent Mater 2022; 38:907-923. [DOI: 10.1016/j.dental.2022.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 03/01/2022] [Accepted: 03/02/2022] [Indexed: 11/18/2022]
|
25
|
Vilde T, Stewart CA, Finer Y. Simulating the Intraoral Aging of Dental Bonding Agents: A Narrative Review. Dent J (Basel) 2022; 10:dj10010013. [PMID: 35049611 PMCID: PMC8775087 DOI: 10.3390/dj10010013] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 12/27/2021] [Accepted: 01/12/2022] [Indexed: 02/01/2023] Open
Abstract
Despite their popularity, resin composite restorations fail earlier and at higher rates than comparable amalgam restorations. One of the reasons for these rates of failure are the properties of current dental bonding agents. Modern bonding agents are vulnerable to gradual chemical and mechanical degradation from a number of avenues such as daily use in chewing, catalytic hydrolysis facilitated by salivary or bacterial enzymes, and thermal fluctuations. These stressors have been found to work synergistically, all contributing to the deterioration and eventual failure of the hybrid layer. Due to the expense and difficulty in conducting in vivo experiments, in vitro protocols meant to accurately simulate the oral environment’s stressors are important in the development of bonding agents and materials that are more resistant to these processes of degradation. This narrative review serves to summarize the currently employed methods of aging dental materials and critically appraise them in the context of our knowledge of the oral environment’s parameters.
Collapse
Affiliation(s)
- Tomas Vilde
- Faculty of Dentistry, University of Toronto, Toronto, ON M5S 1A1, Canada; (T.V.); (C.A.S.)
| | - Cameron A. Stewart
- Faculty of Dentistry, University of Toronto, Toronto, ON M5S 1A1, Canada; (T.V.); (C.A.S.)
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 1A1, Canada
| | - Yoav Finer
- Faculty of Dentistry, University of Toronto, Toronto, ON M5S 1A1, Canada; (T.V.); (C.A.S.)
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 1A1, Canada
- Correspondence:
| |
Collapse
|
26
|
Vieira BR, Dantas ELDA, Cavalcanti YW, Santiago BM, Sousa FBD. Comparison of Self-Etching Adhesives and Etch-and-Rinse Adhesives on the Failure Rate of Posterior Composite Resin Restorations: A Systematic Review and Meta-Analysis. Eur J Dent 2021; 16:258-265. [PMID: 34808690 PMCID: PMC9339922 DOI: 10.1055/s-0041-1736332] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Abstract
The aim of this study was to perform a systematic review with meta-analysis on the comparison of self-etching adhesives and etch-and-rinse adhesives with respect to the failure rate of posterior composite resin restorations. The study protocol was registered in PROSPERO (CRD42017078015), following PRISMA recommendations and PICO search strategy. Literature search was performed in the following databases: MEDLINE, ISI Web of Science, LILACS, SCOPUS, and Cochrane Library through July 2021. Six studies from five randomized clinical trials were included in the qualitative synthesis. The funnel plot detected important bias (all studies out of the funnel area). The meta-analysis showed a positive summary Cohen H effect size of 0.406 (95% CI: 0.100; 0.713, p = 0.009), favoring etch-and-rinse adhesives. The total number of failures (including restorations that required replacement and those that did not require replacement) were attributed to either marginal adaptation (five studies) or marginal staining (one study). A very low certainty of the evidence was obtained through GRADE analysis. In conclusion, current available evidence indicates that etch-and rinse adhesives performed better (with a low effect size) than self-etching adhesives in terms of failure rates in posterior composite restorations.
Collapse
Affiliation(s)
- Basílio Rodrigues Vieira
- Graduate Program in Dentistry, Health Sciences Center, Federal University of Paraíba, João Pessoa, Paraiba, Brazil
| | | | - Yuri Wanderley Cavalcanti
- Department of Clinical and Social Dentistry, Health Sciences Center, Federal University of Paraíba, João Pessoa, Paraiba, Brazil
| | - Bianca Marques Santiago
- Department of Clinical and Social Dentistry, Health Sciences Center, Federal University of Paraíba, João Pessoa, Paraiba, Brazil
| | - Frederico Barbosa de Sousa
- Department of Morphology, Health Sciences Center, Federal University of Paraíba, João Pessoa, Paraiba, Brazil
| |
Collapse
|
27
|
Araújo-Neto VG, Moreira MM, Ñaupari-Villasante R, De Paula DM, Medeiros S, Loguercio AD, Feitosa VP. Nanofiller Particles and Bonding Durability, Water Sorption, and Solubility of Universal Adhesives. Oper Dent 2021; 46:690-697. [PMID: 35507899 DOI: 10.2341/20-239-l] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/27/2021] [Indexed: 11/23/2022]
Abstract
The aim of this study was to evaluate the influence of nanofiller particles in simplified universal adhesive on the long-term microtensile bond strength and silver nitrate up-take, as well as water sorption and solubility. Commercial adhesives Ambar Universal (FGM) in nanofilled-containing version (filled) and same lot without fillers (unfilled) were donated and applied by means of etch-and-rinse strategy. Microtensile bond strength was surveyed after 24-hours or 1-year water storage. Silver nitrate uptake was assayed using scanning electron microscopy (SEM). Water sorption and solubility experiments were performed based on ISO 4049:2009. Statistical analysis was performed using two-way ANOVA and Tukey test (p<0.05). The bond strength of both the adhesives were statistically similar at 24 hours (p>0.05), but the filled group attained significant bond strength reduction after aging when compared to initial bond strength (p<0.001). Conversely, unfilled adhesive presented stable adhesion after 1-year storage (p=0.262). Silver nitrate uptake was similar for both adhesives, with little silver impregnation at the hybrid and adhesive layers. Water sorption was higher with filled adhesive compared to the unfilled one (p=0.01). Conversely, solubility was higher in unfilled in comparison to filled one (p=0.008). The presence of nanofillers in universal adhesive achieves higher water sorption and dentin bond degradation, which did not occur in the unfilled adhesive.
Collapse
Affiliation(s)
- V G Araújo-Neto
- *Vitaliano Gomes Araújo-Neto, Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - M M Moreira
- Madiana Magalhães Moreira, DDS, MS, Post-graduation Program in Dentistry, Federal University of Ceará, Fortaleza, Brazil
| | - R Ñaupari-Villasante
- RominaÑaupari-Villasante, DDS, Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| | - D M De Paula
- Diego Martins De Paula, DDS, MS, PhD, Paulo Picanço School of Dentistry, Fortaleza, Brazil
| | - Stcb Medeiros
- Samara Tabata Cavalcante Braga Medeiros, DDS student, Paulo Picanço School of Dentistry, Fortaleza, Brazil
| | - A D Loguercio
- Alessandro Dourado Loguercio, DDS, MS, PhD, Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| | - V P Feitosa
- Victor Pinheiro Feitosa, DDS, MS, PhD, Paulo Picanço School of Dentistry, Fortaleza, Brazil
| |
Collapse
|
28
|
Kaviani A, Khansari Nejad N. Effect of Nd:YAG and Er:YAG laser tooth conditioning on the microleakage of self-adhesive resin cement. Biomater Investig Dent 2021; 8:152-159. [PMID: 34693293 PMCID: PMC8530498 DOI: 10.1080/26415275.2021.1990063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Statement of problem Recently, the application of lasers in restorative dentistry has been considered for cavity preparation and surface conditioning of enamel and dentin. However, the beneficial effects of cavity surface conditioning by laser irradiation on microleakage are still controversial. Purpose This study aimed to compare the microleakage of self-etch adhesive resin cement with Nd:YAG and Er:YAG laser tooth surface conditioning to evaluate the capabilities of these lasers as a reliable replacement for etching cavities. Materials and methods Fifty-four class V cavities were prepared on the buccal and lingual surfaces of 27 sound human premolar teeth. The samples were randomly divided into three groups (n = 18): group 1: no conditioning; group 2: conditioned with Er:YAG laser (2940 nm, 10 Hz, 1.2 W); group 3: conditioned with Nd:YAG laser (1064 nm, 1.5 W, 10 Hz). All the cavities were filled with self-adhesive resin cement. After curing and polishing, the samples were immersed in 2% methylene blue solution for 24 h, and after being embedded in acrylic resin, they were sectioned longitudinally and examined under a stereomicroscope. The data were submitted to Kruskal–Wallis and Dunn tests (α = 0.05). Results The lowest microleakage mean rank was observed in the Er:YAG group (19.19), and the highest mean rank was noted in the Nd:YAG group (33.08), with significant differences between the three groups (P-value = .01). Pairwise comparisons demonstrated significant differences between the Er:YAG and Nd:YAG groups (P-value = .004) as well as Er:YAG and no conditioned groups (P-value =.022). Conclusion The irradiation of the Er:YAG laser (2940 nm, 10 Hz, 1.2 W) on cavity surface resulted in less marginal microleakage of self-etch adhesive resin cement restorations compared to Nd:YAG (1064 nm, 1.5 W, 10 Hz) and no conditioning groups.
Collapse
Affiliation(s)
- Azita Kaviani
- Department of Operative Dentistry, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | | |
Collapse
|
29
|
Deb A, Pai V, Akhtar A, Nadig RR. Evaluation of Microleakage of Micro Hybrid Composite Resins versus Chitosan-Incorporated Composite Resins When Restored in Class V Cavities Using Total Etch and Self-Etch Adhesives: An In vitro Study. Contemp Clin Dent 2021; 12:346-351. [PMID: 35068832 PMCID: PMC8740799 DOI: 10.4103/ccd.ccd_414_20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Revised: 07/13/2020] [Accepted: 09/07/2020] [Indexed: 11/05/2022] Open
Abstract
Aim: To evaluate the in-vitro microleakage of traditional micro hybrid composite resin and 0.2% chitosan-incorporated composite resin when restored in Class V cavities using total etch versus self-etch adhesives after storing in artificial saliva for 24 h. Materials and Methodology: Sixty permanent maxillary premolars collected and Class V cavities were prepared on buccal surface of each tooth (dimensions: mesio-distally 3 mm, occluso cervically 2 mm, and depth of 1.5 mm) and restored with Group 1: micro hybrid (30 teeth) and Group 2: chitosan-incorporated composite (30 teeth), which was further subdivided into: (a) 15 teeth using total-etch adhesives. (b) 15 teeth using self-etch adhesives. Next dye extraction test was carried out using spectrophotometer. Results: Comparison within groups: In Group 1: Self-etch demonstrated less microleakage (0.0129) compared with total etch (0.0183). The difference was statistically significant, and in Group 2: No statistically significant difference was found in mean microleakage scores after using either self-etch (0.0118) or total etch adhesives (0.0120). Conclusion: It can be concluded that chitosan-incorporated composite seems to have improved mechanical properties with a stable bond when used with either self-etch or total etch adhesives in addition to being antibacterial. It may be clinically useful in restoring Class V cavities in patients with high caries risk. However, further in vitro and in-vivo studies need to be carried out.
Collapse
Affiliation(s)
- Arpita Deb
- Department of Conservative Dentistry and Endodontics, Dayananda Sagar College of Dental Science, Bengaluru, Karnataka, India
| | - Veena Pai
- Department of Conservative Dentistry and Endodontics, Dayananda Sagar College of Dental Science, Bengaluru, Karnataka, India
| | - Aesha Akhtar
- Department of Conservative Dentistry and Endodontics, Dayananda Sagar College of Dental Science, Bengaluru, Karnataka, India
| | - Roopa R Nadig
- Department of Conservative Dentistry and Endodontics, Dayananda Sagar College of Dental Science, Bengaluru, Karnataka, India
| |
Collapse
|
30
|
Effect of using different component combinations for orthodontic bracket bonding with self-etch primers. J Orofac Orthop 2021; 84:84-92. [PMID: 34581835 DOI: 10.1007/s00056-021-00356-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Accepted: 08/20/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE To evaluate bonding quality for orthodontic bracket bonding with different component combinations of self-etch primers in vitro. METHODS Metallic brackets were bonded to bovine lower incisors and assigned to groups. Group 1: comparison of self-etch (Transbond™ Plus, 3M™ Unitek, Neuss, Germany, n = 30; BrackFix® primer SE, VOCO®, Cuxhaven, Germany, n = 20) and etch-and-rinse bonding systems (Transbond™ XT, n = 20; BrackFix®, n = 20); group 2: comparison of different self-etch primer (Transbond™ Plus; BrackFix® primer SE) and adhesive (Transbond™ XT, n = 20; BrackFix®, n = 20) product combinations; group 3: testing cyclic fatigue bond strength of self-etch bonding systems (Transbond™ Plus, n = 20; BrackFix® primer SE, n = 20). All teeth were tested for shear bond strength according to the DIN-13990 standard, the adhesive remnant index (ARI) and enamel fractures were determined microscopically (10 × magnification). RESULTS The mean shear bond strength of the self-etch (Transbond™ Plus: 16.38 ± 3.68 MPa; BrackFix® primer SE: 16.24 ± 1.73 MPa) and etch-and-rinse bonding systems (Transbond™ XT: 18.45 ± 2.56 MPa; BrackFix®: 17 ± 5.2 MPa) were of a clinically adequate order of magnitude (≥ 6-10 MPa) and were not statistically different. The component combination BrackFix® primer SE/Transbond™ XT adhesive led to a significantly lower shear bond strength (11.99 ± 3.68 MPa). There were no significant differences between static and fatigue shear bond strengths of self-etch bonding systems. Mean ARI scores mostly ranged between 4 and 5. The combination of the self-etch primer Transbond™ Plus with the BrackFix® adhesive led to a significantly increased enamel fracture rate. CONCLUSIONS Based on the present findings bond strength of self-etch primers was equal to etch-and-rinse primers for bracket bonding. Combining different self-etch bonding systems might alter the clinical performance.
Collapse
|
31
|
Sakrana AA, Al-Zordk W, El-Sebaey H, Elsherbini A, Özcan M. Does Preheating Resin Cements Affect Fracture Resistance of Lithium Disilicate and Zirconia Restorations? MATERIALS 2021; 14:ma14195603. [PMID: 34640000 PMCID: PMC8509625 DOI: 10.3390/ma14195603] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 09/20/2021] [Accepted: 09/23/2021] [Indexed: 11/22/2022]
Abstract
This paper assesses the impact of preheating of adhesive cement on the fracture resistance of lithium disilicate and zirconia restorations. Methods: A total of 80 human maxillary premolar teeth were assigned into 8 groups (n = 10) according to material type (either lithium disilicate or zirconia) and type of resin cement (either LinkForce or Panavia SA) with preheating temperature at 54 °C or at room temperature (25 °C). Teeth were prepared and restored with either lithium disilicate or zirconia restorations. After cementation, specimens were thermal cycled (10,000 cycles, 5 °C/55 °C), then load cycled for 240,000 cycles (50 N). Each specimen was statically loaded until fracture and the load (N) at fracture was recorded, then the failure mode was detected. Statistical analysis of data was performed (p ≤ 0.05). Results: There was no significant difference (p = 0.978) in fracture mean values between LinkForce and Panavia SA. Statistically significant difference (p = 0.001) was revealed between fracture resistance of lithium disilicate restorations cemented with LinkForce at 25 °C and at 54 °C; however there was no significant difference (p = 0.92) between the fracture resistance of lithium disilicate restorations cemented with Panavia SA used at 25 °C and at 54 °C. Regarding the interaction between ceramic material, cement type, and cement preheating, there was no significant effect (p > 0.05) in fracture resistance. The cement type does not influence the fracture resistance of ceramic restorations. Preheating of resin cement has negatively influenced the fracture resistance of all tested groups, except for lithium disilicate cemented using LinkForce cement.
Collapse
Affiliation(s)
- Amal Abdelsamad Sakrana
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt; (W.A.-Z.); (H.E.-S.)
- Fixed Prosthodontics Department, Faculty of Dentistry, Horus University, Damietta 34511, Egypt
- Correspondence: ; Tel.: +20-102-384-9099
| | - Walid Al-Zordk
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt; (W.A.-Z.); (H.E.-S.)
- Fixed Prosthodontics Department, Faculty of Dentistry, Horus University, Damietta 34511, Egypt
| | - Heba El-Sebaey
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt; (W.A.-Z.); (H.E.-S.)
- Fixed Prosthodontics Department, Faculty of Dentistry, Horus University, Damietta 34511, Egypt
| | | | - Mutlu Özcan
- Division of Dental Biomaterials, Center for Dental and Oral Medicine, Clinic for Reconstructive Dentistry, University of Zurich, 8032 Zurich, Switzerland;
| |
Collapse
|
32
|
Easter QT. Biopolymer hydroxyapatite composite materials: Adding fluorescence lifetime imaging microscopy to the characterization toolkit. NANO SELECT 2021. [DOI: 10.1002/nano.202100014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Affiliation(s)
- Quinn T. Easter
- Department of Innovation and Technology Research ADA Science & Research Institute Gaithersburg MD USA
| |
Collapse
|
33
|
Fehrenbach J, Isolan CP, Münchow EA. Is the presence of 10-MDP associated to higher bonding performance for self-etching adhesive systems? A meta-analysis of in vitro studies. Dent Mater 2021; 37:1463-1485. [PMID: 34456050 DOI: 10.1016/j.dental.2021.08.014] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 08/16/2021] [Accepted: 08/17/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The purpose of this systematic review and meta-analysis was to analyze the literature on the bond strength of self-etching (SE) adhesives containing 10-MDP or other acidic functional monomers, comparing the bonding performance of both compositions. METHODS This study is registered in PROSPERO (CRD42020175715) and it followed the PRISMA Statement. The literature search was performed in PubMed, Web of Science, SciELO, Scopus, LILACS, IBECS, and BBO from the starting coverage date through 30 June 2021. Study eligibility criteria consisted of in vitro studies that evaluated the bond strength (microtensile, microshear, tensile or shear testing) to sound dentin/enamel of a minimum of two distinct SE systems, with at least one material containing 10-MDP and one other being comprised of a distinct acidic composition. Statistical analyses were carried out with RevMan 5.3.5 and using random-effects models with the significance level at p < 0.05. Also, Bayesian network meta-analysis (NMA) was conducted using MetaInsight V3 tool. RESULTS From 740 relevant studies evaluated in full-text analysis, 210 were incorporated to the systematic review and 206 in meta-analysis. The majority of studies was classified as having medium risk of bias (56.7%), followed by low (35.2%) and high (8.1%) risk of bias. Data from a total of 64 adhesive systems were collected, which favored the 10-MDP-based group at both dentin (overall effect: 6.98; 95% CI: 5.61, 8.36; p < 0.00001) and enamel (overall effect: 2.79; 95% CI: 1.62, 3.96; p < 0.00001) substrates. Microtensile testing was more frequently used (73.4%) in the included studies. Adhesives based on 10-MDP showed greater bonding performance than adhesives comprised of monomers such as PENTA, 6-MHP, 4-META, 4-MET, pyrophosphate esters, mixed composition or monomers derived from sulfonic acid (p ≤ 0.01); whereas similar bond strength values were verified between 10-MDP-based materials and those containing PEM-F, acrylamide phosphates, 4-AET, MAC-10, or monomers derived from polyacrylic and phosphonic acids (p ≥ 0.05). Adhesives based on GPDM were the only ones that resulted in greater bonding potential than the 10-MDP-based group (p = 0.03). Dental bonds in dentin were favored with the application of 2-step 10-MDP-based adhesives; whereas in enamel the dental bonds were favored for both 2-steps versions of adhesives, regardless of the presence of 10-MDP. Indirect evidence from NMA revealed that 1-step 10-MDP-free and universal 10-MDP-free adhesives seemed to perform worst in dentin and enamel, respectively. SIGNIFICANCE Adhesives containing 10-MDP showed higher bonding performance than materials formulated with other acidic ingredients, although this result relied on the type of mechanical testing, type of the substrate, acidic composition of the adhesive, and the application category of the SE system. This review summarized the effects of the foregoing factors on the adhesion to dental substrates.
Collapse
Affiliation(s)
- Julia Fehrenbach
- Graduate Program in Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492, Santa Cecília, Porto Alegre, Brazil.
| | - Cristina Pereira Isolan
- Department of Restorative Dentistry, School of Dentistry, Federal University of Jequitinhonha and Mucuri Valleys, Rua da Glória, 187, Centro, Diamantina, Brazil.
| | - Eliseu Aldrighi Münchow
- Graduate Program in Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492, Santa Cecília, Porto Alegre, Brazil; Department of Conservative Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492, Porto Alegre, Brazil.
| |
Collapse
|
34
|
Fluoride-Releasing Self-Etch Adhesives Create Thick ABRZ at the Interface. BIOMED RESEARCH INTERNATIONAL 2021; 2021:9731280. [PMID: 34368356 PMCID: PMC8346310 DOI: 10.1155/2021/9731280] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Accepted: 07/16/2021] [Indexed: 11/17/2022]
Abstract
A fluoride-releasing adhesive system is expected to promote mineralization of demineralized dentin/enamel around a composite restoration, thereby contributing to the longevity of the restoration. Scanning electron microscopic (SEM) and transmission electron microscopic (TEM) observations revealed the formation of an “acid–base resistant zone” (ABRZ) beneath the hybrid layer when dentin was treated with a self-etch adhesive system. A thicker ABRZ was formed from the upper slope to the end of the outer lesion, indicating greater resistance against an acid-base challenge, when a fluoride-releasing self-etch adhesive system was used. The slope formation of a fluoride-releasing adhesive is believed to be due to fluoride-release from the adhesive. Quantitative assessment of the acid resistance was performed at the interface using the region of interest (ROI) mode of a digital image analysis software package. The area of the ABRZ is influenced by the concentration of fluoride release from the adhesive resin. The threshold of fluoride concentration in the adhesive may exist to influence the morphology of the ABRZ. X-ray absorption fine structure (XAFS) analysis of the dentin treated with different concentrations of NaF-mouth rinses suggested that different fluoride concentrations result in the formation of different chemical compounds, such as fluorapatite and CaF2-like structures, on the dentin surface. This may explain the differences in μTBS values and morphological appearance of the ABRZ. NaF is effective in enhancing the enamel/dentin bond durability and also helps create a high quality of ARBZ to improve the clinical success of restorations.
Collapse
|
35
|
Oltramare R, Par M, Mohn D, Wiedemeier DB, Attin T, Tauböck TT. Short- and Long-Term Dentin Bond Strength of Bioactive Glass-Modified Dental Adhesives. NANOMATERIALS 2021; 11:nano11081894. [PMID: 34443725 PMCID: PMC8398528 DOI: 10.3390/nano11081894] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/12/2021] [Accepted: 07/15/2021] [Indexed: 11/16/2022]
Abstract
This study investigated the short- and long-term effects of dental adhesives doped with nano-sized bioactive glass 45S5 (BAG) on the resin-dentin interfacial bond strength. Two etch-and-rinse adhesives (Adper Scotchbond Multi-Purpose (ASB) and Solobond Plus (SB)) and one self-etch adhesive (Clearfil SE Bond (CF)) were doped with different concentrations of BAG (5, 10, and 20 wt%). The unmodified (0 wt% BAG) commercial adhesives served as control groups. Dentin of 120 molars (n = 10 per group) was treated with the different adhesives, followed by buildups with a conventional composite restorative material. From each tooth, 14 sticks were prepared for micro-tensile bond strength (µTBS) testing. The sticks were stored in simulated body fluid at 37 °C and tested after 24 h or six months for µTBS and failure mode. Data were analyzed using Kruskal-Wallis tests in combination with post-hoc Conover-tests and Wilcoxon signed-rank tests at a level of significance of α = 0.05. After 24 h and six months, both etch-and-rinse adhesives with a low BAG content (up to 10 wt% for ASB and 5 wt% for SB) showed similar µTBSs as their respective control groups (0 wt% BAG). CF showed a significant decrease in µTBS even after addition of 5 wt% BAG. At a high concentration of added BAG (20 wt%), all three adhesives showed a significant decrease in µTBS compared to the unmodified controls. The CF control group showed significantly lower µTBS after 6 months of storage than after 24 h. In contrast, the µTBS of all CF groups modified with BAG was unaffected by aging. In conclusion, the tested etch-and-rinse adhesives can be modified with up to 5 wt% (SB), or 10 wt% (ASB) of BAG without reducing their short- and long-term dentin bond strength. Moreover, the addition of nano-sized BAG may prevent long-term bond strength deterioration of a self-etch adhesive.
Collapse
Affiliation(s)
- Ramona Oltramare
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (D.M.); (T.A.); (T.T.T.)
- Correspondence: ; Tel.: +41-44-634-33-63
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia;
| | - Dirk Mohn
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (D.M.); (T.A.); (T.T.T.)
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zurich, 8093 Zurich, Switzerland
| | - Daniel B. Wiedemeier
- Statistical Services, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland;
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (D.M.); (T.A.); (T.T.T.)
| | - Tobias T. Tauböck
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (D.M.); (T.A.); (T.T.T.)
| |
Collapse
|
36
|
Cevval Ozkocak BB, Aytac Bal F. Effect of diode laser-assisted bleaching on the bond strength of different adhesive systems to enamel: Interfacial SEM analysis. Microsc Res Tech 2021; 84:1542-1552. [PMID: 33511727 DOI: 10.1002/jemt.23711] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 12/19/2020] [Accepted: 01/08/2021] [Indexed: 11/08/2022]
Abstract
The aim of this study was to investigate the effectiveness of diode laser-assisted bleaching on the shear bond strength (SBS) of different adhesive systems to enamel and examine the adhesive enamel interface under scanning electron microscope (SEM). 180 incisor teeth were randomly divided into three bleaching groups: (1) Unbleached control group, (2) Opalescence Boost (OB) 40%, and (3) Diode laser-assisted LaserWhite20 (LW20) 45%. After bleaching, each group was divided into two subgroups according to waiting time: immediately or 7 days' delay. The six groups were then divided into three subgroups based on the adhesive procedure: Single Bond 2 (SB2), Clearfil SE Bond (CSB), and Clearfil Universal Bond (CUB). After adhesive procedures, composite resin cylinders were bonded to the enamel surfaces. All specimens were subjected to a SBS test after 24 hr of storage in water. Data were analysed using three-way variance analysis (p < .05). Specimens were examined under a stereomicroscope and SEM. There was a significant difference between the groups bonded immediately and 7 days after bleaching (p < .05). SB2 after 7 days showed the highest SBS values (19.24 ± 2.18), whereas CUB showed the lowest values in both bleaching treatments and control groups (10.84 ± 1.66). SEM analysis of the unbleached specimens revealed long tags and uniform hybrid layer compared OB and LW20 bleaching groups. LW20 and OB bleaching adversely affected SBS to enamel when bonded immediately. Diode laser-assisted bleaching might be an alternative option due to the short working time but delaying bonding for 7 days after bleaching may not be enough for ideal adhesion. RESEARCH HIGHLIGHTS: Bleaching agents containing high concentration hydrogen peroxide reduces the enamel bond strength of adhesive systems. Postponing composite restorations for 7 days after bleaching may not be sufficient to achieve ideal adhesion. Diode laser-assisted bleaching may be preferred as an alternative bleaching method today due to its ability to shorten the operation time and cause minimal morphological changes on the enamel surface.
Collapse
Affiliation(s)
- Begum Busra Cevval Ozkocak
- Faculty of Dentistry, Department of Restorative Dentistry, Bolu Abant Izzet Baysal University, Bolu, Turkey
| | - Fatma Aytac Bal
- Faculty of Dentistry, Department of Restorative Dentistry, Beykent University, Istanbul, Turkey
| |
Collapse
|
37
|
Farooq I, Ali S, Al-Saleh S, AlHamdan EM, AlRefeai MH, Abduljabbar T, Vohra F. Synergistic Effect of Bioactive Inorganic Fillers in Enhancing Properties of Dentin Adhesives-A Review. Polymers (Basel) 2021; 13:polym13132169. [PMID: 34209016 PMCID: PMC8271823 DOI: 10.3390/polym13132169] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 06/23/2021] [Accepted: 06/25/2021] [Indexed: 02/07/2023] Open
Abstract
Dentin adhesives (DAs) play a critical role in the clinical success of dental resin composite (DRC) restorations. A strong bond between the adhesive and dentin improves the longevity of the restoration, but it is strongly dependent on the various properties of DAs. The current review was aimed at summarizing the information present in the literature regarding the improvement of the properties of DAs noticed after the addition of bioactive inorganic fillers. From our search, we were able to find evidence of multiple bioactive inorganic fillers (bioactive glass, hydroxyapatite, amorphous calcium phosphate, graphene oxide, calcium chloride, zinc chloride, silica, and niobium pentoxide) in the literature that have been used to improve the different properties of DAs. These improvements can be seen in the form of improved hardness, higher modulus of elasticity, enhanced bond, flexural, and ultimate tensile strength, improved fracture toughness, reduced nanoleakage, remineralization of the adhesive-dentin interface, improved resin tag formation, greater radiopacity, antibacterial effect, and improved DC (observed for some fillers). Most of the studies dealing with the subject area are in vitro. Future in situ and in vivo studies are recommended to positively attest to the results of laboratory findings.
Collapse
Affiliation(s)
- Imran Farooq
- Faculty of Dentistry, University of Toronto, Toronto, ON M5G 1G6, Canada
- Correspondence:
| | - Saqib Ali
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia;
| | - Samar Al-Saleh
- Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (S.A.-S.); (E.M.A.); (T.A.); (F.V.)
| | - Eman M. AlHamdan
- Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (S.A.-S.); (E.M.A.); (T.A.); (F.V.)
| | - Mohammad H. AlRefeai
- Operative Division, Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia;
| | - Tariq Abduljabbar
- Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (S.A.-S.); (E.M.A.); (T.A.); (F.V.)
| | - Fahim Vohra
- Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (S.A.-S.); (E.M.A.); (T.A.); (F.V.)
| |
Collapse
|
38
|
Sabbagh J, El Masri L, Fahd JC, Nahas P. A three-year randomized clinical trial evaluating direct posterior composite restorations placed with three self-etch adhesives. Biomater Investig Dent 2021; 8:92-103. [PMID: 34240061 PMCID: PMC8238063 DOI: 10.1080/26415275.2021.1939034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Aim To compare the clinical performance of composite restorations placed with a universal adhesive, one-step and two-step self-etch adhesives in class I and II posterior cavities. Materials and methods In this in vivo study, 46 volunteers presenting with at least three carious lesions were included. Each participant received the three restorative systems: universal adhesive/nanofilled composite (Scotchbond Universal/Filtek Z350 XT: SBU/FZXT), one-step self-etch adhesive/microhybrid composite (G-aenial bond/G-aenial Posterior: GB/GP) and the two-step self-etch adhesive/nanohybrid composite (OptiBond XTR/Herculite Ultra: OBX/HU). The adhesives were all placed in self-etch mode. In total, 138 restorations were evaluated at baseline and at 6,12 and 36 months using the modified United States Public Health Service criteria. Data were analysed using Kruskal-Wallis, Mann-Whitney U, Friedman and Wilcoxon non-parametric tests (p < .05). Ninety-one restorations were evaluated at 36 months. Results Seven restorations, three SBU/FZXT, three GB/GP and one OBX/HU failed during this study. The reasons for failure were marginal fracture and secondary caries. SBU/FZXT restorations showed significant marginal deterioration in all parameters. Overall success rates were: 93.5% (SBU/FZXT), 96.6% (GB/GP) and 96.8% (OBX/HU). Conclusions After three years, the three restorative systems have comparable clinical effectiveness and success rates, except for the marginal integrity, that was suboptimal for both the SBU/FZXT and GB/GP restorations in comparison to the OBX/HU restorations.
Collapse
Affiliation(s)
- Joseph Sabbagh
- Department of Restorative and aesthetic dentistry and Endodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| | - Layal El Masri
- Department of Restorative and aesthetic dentistry and Endodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| | - Jean Claude Fahd
- Department of Restorative and aesthetic dentistry and Endodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| | - Paul Nahas
- Department of Restorative and aesthetic dentistry and Endodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| |
Collapse
|
39
|
Cavalheiro A, Cruz J, Sousa B, Silva A, Coito C, Lopes M, Vargas M. Dentin adhesives application deviations: Effects on permeability and nanoleakage. Dent Mater J 2021; 40:1160-1168. [PMID: 34024885 DOI: 10.4012/dmj.2020-404] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose was to evaluate the effect that deviations from the recommended protocol of a two-step etch-and-rinse adhesive system has on permeability and nanoleakage. One hundred and twenty dentin disks were treated with a two-step etch-and-rinse adhesive system, according to the manufacturer's instructions, or using five simulated deviations from the recommended protocol: applying potassium oxalate, reducing the application time of the adhesive, avoiding adhesive drying, aggressively drying the adhesive, and double application of adhesive. Kruskal-Wallis and Tukey's post hoc comparisons were used to evaluate the permeability reduction (α=0.05). Twelve additional dentin disks were prepared for transmission electron microscope (TEM) analysis of nanoleakage. Aggressive drying, adding additional layers of adhesive or using oxalate reduced dentin permeability and yielded a better infiltration of the hybrid layer, whereas reducing the application time or less drying the adhesive did not to reduce dentin permeability, caused extensive nanoleakage, showing immediate compromised dentin sealing.
Collapse
Affiliation(s)
- Alexandre Cavalheiro
- Department of Operative Dentistry, Faculty of Dental Medicine, Universidade de Lisboa, Rua Professora Teresa Ambrósio, Cidade Universitária
| | - Joana Cruz
- Department of Operative Dentistry, Faculty of Dental Medicine, Universidade de Lisboa, Rua Professora Teresa Ambrósio, Cidade Universitária
| | - Bernardo Sousa
- Department of Operative Dentistry, Faculty of Dental Medicine, Universidade de Lisboa, Rua Professora Teresa Ambrósio, Cidade Universitária
| | - Ana Silva
- Department of Operative Dentistry, Faculty of Dental Medicine, Universidade de Lisboa, Rua Professora Teresa Ambrósio, Cidade Universitária
| | - Catarina Coito
- Department of Operative Dentistry, Faculty of Dental Medicine, Universidade de Lisboa, Rua Professora Teresa Ambrósio, Cidade Universitária
| | - Manuela Lopes
- Department of Cellular and Molecular Biology, Faculty of Dental Medicine, Universidade de Lisboa, Rua Professora Teresa Ambrósio, Cidade Universitária
| | - Marcos Vargas
- Department of Family Dentistry, College of Dentistry, University of Iowa
| |
Collapse
|
40
|
Tran XV, Tran KQ. Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems. Restor Dent Endod 2021; 46:e30. [PMID: 34123766 PMCID: PMC8170381 DOI: 10.5395/rde.2021.46.e30] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 01/12/2021] [Accepted: 01/12/2021] [Indexed: 11/24/2022] Open
Abstract
Objectives This study was conducted to compare the microleakage and characteristics of the resin-tooth tissue interface between self-etch and etch-and-rinse adhesive systems after 48 hours and 3 months. Materials and Methods 40 extracted premolar teeth were randomly divided into 2 groups: 1-step self-etch adhesive system – Optibond™ All-In-One, and 2-step etch-and-rinse adhesive system - Adper™ Single Bond 2. Both groups were subjected to 500 thermocycles (5°C–55°C) before scanning electron microscope (SEM) analysis or microleakage trial at 48-hour and 3-month time periods. Results SEM images showed the hybrid layer thickness, diameter, and length of resin tags of the self-etch adhesive (0.42 ± 0.14 µm; 1.49 ± 0.45 µm; 16.35 ± 14.26 µm) were smaller than those of the etch-and-rinse adhesive (4.39 ± 1.52 µm; 3.49 ± 1 µm; 52.81 ± 35.81 µm). In dentin, the microleakage scores of the 2 adhesives were not different in both time periods (48 hours/3 months). However, the microleakage score of etch-and-rinse adhesive increased significantly after 3 months (0.8 ± 0.63 and 1.9 ± 0.88, p < 0.05). Conclusions The self-etch adhesive exhibited better long-term sealing ability in dentin when compared to that of the etch-and-rinse adhesive. The greater hybrid layer thickness and dimensions of resin tags did not guarantee reliable, long-lasting sealing in the bonding area.
Collapse
Affiliation(s)
- Xuan Vinh Tran
- Faculty of Odonto-stomatology, University of Medicine and Pharmacy at Ho Chi Minh City (UMP), Ho Chi Minh City, Vietnam
| | - Khanh Quang Tran
- Faculty of Odonto-stomatology, University of Medicine and Pharmacy at Ho Chi Minh City (UMP), Ho Chi Minh City, Vietnam
| |
Collapse
|
41
|
Abstract
Current adhesives bond to dentin via a micro-interlocking mechanism within the hybrid layer. Besides such mechanical retention, bonding to dentin would benefit from additional chemical interaction between collagen and resin. This study aims to synthesize a novel light-curable collagen crosslinker methacrylate (MA) functionalized grapeseed extract (GSE) and to assess MAGSE's ability to crosslink dentin collagen in a clinically relevant setting as well as its role in light-cure as a resin. MA functionalization was accomplished by reacting GSE with methacryloyl chloride to obtain MAGSE, which was characterized by 1H-NMR and Fourier transformed infrared spectroscopy (FTIR). The 6-µm-thick dentin films were microtomed from dentin slabs of third molars. Following demineralization, they were treated for 30 s by 1% MAGSE. Collagen crosslinking and resistance to digestion of MAGSE were evaluated by FTIR, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF) assay of films, and scanning electron microscopy (SEM)/transmission electron microscopy (TEM) on slabs. Meanwhile, 1% MAGSE or GSE was added to an experimental adhesive formulated with 2-hydroxyethyl methacrylate and a tricomponent photoinitiator system. Polymerization kinetics were monitored continuously in real time for 10 min using FTIR-attenuated total reflection. The results indicated that MAGSE could bind to dentin collagen and protect it from collagenase degradation as strong as GSE. Dentin collagen treated by 1% MAGSE for 30 s was scarcely digested (1.6 ± 1.6%) after 1 h in 0.1% collagenase, while untreated collagen was completely digested (100.9 ± 20.2%). SEM/TEM images indicated MAGSE efficiently crosslinked dentin collagen in 30 s and rendered it almost inert to digestion under clinically relevant settings. Unlike GSE that hindered light-curing of HEMA, MAGSE accelerated the rate of polymerization and exhibited typical traits of a resin monomer with multiple polymerizable units. In conclusion, a novel collagen crosslinking resin MAGSE is synthesized, which inherits collagen crosslinking ability from GSE and polymerization function from MA. Inclusion of this light-curable collagen crosslinker into adhesives might be a revolutionary way to improve durability of dentin bonding in composite restorations.
Collapse
Affiliation(s)
- Y Wang
- University of Missouri-Kansas City School of Dentistry, Kansas City, MO, USA
| | - Y Liu
- University of Missouri-Kansas City School of Dentistry, Kansas City, MO, USA
| | - H Liu
- University of Missouri-Kansas City School of Dentistry, Kansas City, MO, USA
| | - S Li
- University of Missouri-Kansas City School of Dentistry, Kansas City, MO, USA
| |
Collapse
|
42
|
Almahdy A. Influence of Photodynamic therapy and different gingival retraction agents on bond integrity of composite to dentin. Photodiagnosis Photodyn Ther 2021; 34:102269. [PMID: 33785440 DOI: 10.1016/j.pdpdt.2021.102269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Revised: 03/18/2021] [Accepted: 03/22/2021] [Indexed: 10/21/2022]
Abstract
AIM The present study was undertaken to evaluate the influence of gingival retraction agents (Expasyl and Viscostat) and different conditioning methods (Total-etch, Self-etch, and PDT) on bond integrity of composite to dentin. MATERIAL AND METHODS One hundred and eighty, third molars were collected cleaned and disinfected in thymol solution. The specimens were rooted vertically up to cementoenamel junction within polyvinyl cylinders (PVC). Based on gingival retraction materials samples were divided into three groups (n = 60). Group A: dentin applied with Expasyl; Group B: Viscostat was applied on dentin and Group C: Control. Dentin surface was treated with different surface conditioners. Etch and rinse, PDT MBP, and Two-step self-etch. A bonding agent was applied and composite buildup was done. Samples were placed in the universal testing machine for SBS. Bond failure was assessed using a stereomicroscope. Analysis of variance (ANOVA) and Tukey's post hoc test compared the means and standard deviations (SD) after SBS testing (p = 0.05). RESULTS The highest score of bond strength was exhibited by group C1 (21.14 ± 1.05 MPa-Etch & rinse + Tetric-N- Bond) whereas group C2 (12.15 ± 0.28 -PDT MBPS + Tetric-N-Bond, No treatment group) demonstrated the lowest SBS. Based on the application of haemostatic agent, bond values among subgroups A1 (18.75 ± 1.05 MPa - Expasyl + Etch & rinse + Tetric-N-bond) and B1 (17.84 ± 0.11 MPa -Viscostat + Etch & rinse + Tetric-N-Bond) was comparable (p>0.05). Based on the conditioning methods, bond scores among groups C1 (21.14 ± 1.05 MPa -Etch & rinse + Tetric-N- Bond) and C3 (19.05 ± 1.28 MPa -Clearfill SE) were comparable (p >0.05). CONCLUSION Viscostat and Expasyl result in compromised bond integrity of composite restoration to dentin in etch and rinse and self-etch group compared to no treatment group. However, the pre-application of Viscostat and Expasyl on dentin conditioned with PDT improved bond integrity of composite resin.
Collapse
Affiliation(s)
- Ahmed Almahdy
- Pediatric Dentistry and Orthodontic Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| |
Collapse
|
43
|
Cardoso RFDM, Basting RT, França FMG, Amaral FLBD, Basting RT. Physicochemical characterization, water sorption and solubility of adhesive systems incorporated with titanium tetrafluoride, and its influence on dentin permeability. J Mech Behav Biomed Mater 2021; 119:104453. [PMID: 33780849 DOI: 10.1016/j.jmbbm.2021.104453] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 03/07/2021] [Accepted: 03/09/2021] [Indexed: 01/02/2023]
Abstract
Titanium tetrafluoride (TiF4) in an aqueous solution can decrease dentin permeability, but some effects of its incorporation into adhesive systems are not yet known. Therefore, the aim of this study was to characterize the physicochemical, water sorption (WS) and solubility (SL) properties of two adhesive systems (Clearfil SE Bond/C and Scotchbond Universal/S) incorporated with 0.0% (T0), 2.5% (T2) and 4.0% (T4) titanium tetrafluoride (TiF4), and determine dentin permeability (L) after application of these adhesive systems both immediately afterwards (baseline) and after 6 months of storage. The physicochemical analyses of the incorporated solutions were performed based on evaluating particle size (PS), polydispersity index (PDI) by dynamic light scattering, and zeta potential (ZP) by electrophoresis. WS and SL tests followed ISO 4049 standards, and used a 7-day water storage period. The L test was performed by analyzing human dentin discs before and after adhesive system application, and after storage. PS and PDI were higher for CT0 and ST4 (p < 0.0001; ANOVA, Tukey). ZP was lower for CT4, ST2 and ST4 (p < 0.0001; ANOVA, Tukey). A 4.0% TiF4 incorporation showed higher WS (p < 0.05; Mann Whitney, Kruskal Wallis, Dunn). Higher SL was observed for CT0 and ST4 (p < 0.05; Mann Whitney, Kruskal Wallis, Dunn). The L value at baseline was lower for ST4, but was not different from the CT4 groups after storage (p < 0.05; Mann Whitney, Kruskal Wallis, Dunn). It can be concluded that TiF4 affected the colloidal stability of Scotchbond, but did not alter the other properties. The 2.5% TiF4 did not affect the PDI, WS or L of the Clearfil, and can be considered an alternative for reducing hybrid layer degradation.
Collapse
Affiliation(s)
| | - Rosanna Tarkany Basting
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, CEP: 13045-755, São Paulo, Brazil.
| | | | | | - Roberta Tarkany Basting
- Faculdade São Leopoldo Mandic, Rua José Rocha Junqueira 13, Bairro Swift, Campinas, CEP: 13045-755, São Paulo, Brazil.
| |
Collapse
|
44
|
Does Adhesive Layer Thickness and Tag Length Influence Short/Long-Term Bond Strength of Universal Adhesive Systems? An In-Vitro Study. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11062635] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
(1) Background: This study investigated the effect of the adhesive layer thickness and the length of resin tags on dentin bond strength of five universal adhesives applied in self-etch mode. (2) Methods: One hundred and fifty extracted human third molars were used. Five different universal adhesives were applied in self-etch mode on the dentin surface. Half of the specimens were subjected to an aging procedure for six months. A shear bond strength (SBS) test was performed and the results were statistically analyzed with a t-test and one-way ANOVA test. Scanning electron microscopy (SEM) was executed to measure the adhesive layer thickness and tag depth. (3) Results: No statistical differences were found between the five adhesive systems after a 24 h storage period, regardless of layer thickness and tag depth (p < 0.05). After 6 months of aging in water at 37 °C, Iperbond Max and Scotchbond Universal preserved the bond strength over time (p < 0.05), whilst the SBS of Iperbond Ultra, FuturaBond M+, and Ibond Universal decreased significantly after the aging period. No relation was observed between the adhesive thickness or tags’ length on SBS. (4) Conclusions: Within the limitation of this study, the stability over time of the bond strength of universal adhesives depends on their compositions regardless of the adhesive layer thickness and/or tags’ length.
Collapse
|
45
|
Hegde N, Attavar S, Hegde MN, Hegde ND. Comparative analysis of bond strength and microleakage of newer generation bonding agents to enamel and dentin: An in vitro study. J Conserv Dent 2021; 23:593-597. [PMID: 34083915 PMCID: PMC8095691 DOI: 10.4103/jcd.jcd_572_20] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 12/05/2020] [Accepted: 12/14/2020] [Indexed: 11/04/2022] Open
Abstract
Aims This study aims to evaluate the bond strength (BS) and microleakage (ML) of the newer bonding agents to enamel and dentin. Objective (1) To analyze the BS between self-etch and total-etch adhesives. (2) To analyze the depth of ML between self-etch and total-etch adhesives. Materials and Methods Sixty mandibular premolars were fabricated and randomly divided into three groups: Group I (n = 20)-bonded with self-etch adhesive + nanohybrid, Group II (n = 20) with total-etch adhesive + micro hybrid and Group III (n = 20) with total-etch adhesive + nanocomposite. Teflon ring molds were used to make composite resin cylinders bonded to the buccal surface. Class II box cavity was prepared on the samples' proximal surface and condensed with composite resin with each group's specific bonding protocol. Shear BS and ML testing were conducted, and data analyzed. Statistical Analysis Kruskal-Wallis analysis was done to statistically differentiate the BS and ML between the three experimental groups; the P < 0.05, it showed a statistically significant difference. Intergroup comparison was made using the Mann-Whitney U test. Conclusions Within this study's limitation, resin bonded with self-etch G-Premio Bond used in selective etch technique showed the highest BS and resistance to ML.
Collapse
Affiliation(s)
- Nishmitha Hegde
- Department of Conservative Dentistry and Endodontics, A.B. Shetty Memorial Institute of Dental Sciences, Mangalore, Karnataka, India
| | - Shruthi Attavar
- Department of Conservative Dentistry and Endodontics, A.B. Shetty Memorial Institute of Dental Sciences, Mangalore, Karnataka, India
| | - Mithra N Hegde
- Department of Conservative Dentistry and Endodontics, A.B. Shetty Memorial Institute of Dental Sciences, Mangalore, Karnataka, India
| | - Nidarsh D Hegde
- Department of Oral and Maxillofacial Surgery, Dental College, JNIMS, Imphal, Manipur, India
| |
Collapse
|
46
|
Maciel CM, da Rosa Rinhel MF, Abuna GF, Pacheco RR, da Silva-Concílio LR, Baroudi K, Sinhoreti MAC, Vitti RP. Resin composite adhesion to dentin using different curing lights and adhesive systems applied under electric current. Clin Oral Investig 2021; 25:5181-5188. [PMID: 33558973 DOI: 10.1007/s00784-021-03824-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Accepted: 02/02/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To evaluate the effect of electric current application on the resin composite-tooth bond strength and hybrid layer of three adhesive systems light-cured by two light-curing units (LCUs). MATERIALS AND METHODS Human molar teeth were distributed into 12 groups (n=6). Three adhesive systems were used: two-step etch-and-rinse (SB2; Adper Single Bond 2, 3M ESPE); two-step self-etch (CSE; Clearfil SE Bond, Kuraray); and one-step self-etch (SBU; Single Bond Universal, 3M ESPE) applied with (50μA) and without (control; conventional application) electric current, and light-cured with different LCUs. Resin composite blocks (Filtek Z350XT, 3M ESPE) were produced and cut into sticks (~1mm2) for microtensile bond strength (μTBS). Fracture patterns were analyzed on stereomicroscope and classified as cohesive-dentin, cohesive-resin, adhesive, or mixed. Specimens were prepared for scanning electron microscope observation. The hybrid layer analysis was carried out using a confocal laser scanning microscopy (n=2). Data were submitted to three-way ANOVA followed by Tukey's post hoc test (α=0.05). RESULTS The electric current increased the μTBS for all adhesive systems light-cured with single-emission peak and multiple-emission peak LCUs. Both LCUs presented similar μTBS values. CSE applied under electric current showed the highest μTBS mean values. The adhesive failure pattern was more frequently observed in all groups. The electric current formed long resin tags for all adhesive systems. CONCLUSIONS The adhesive systems applied under electric current increased the bond strength using single-emission peak and multiple-emission peak LCUs. CLINICAL RELEVANCE Electric current at 50μA applied throughout the dentin is a safe mode and results in better impregnation of the adhesive systems.
Collapse
Affiliation(s)
| | | | | | | | | | - Kusai Baroudi
- School of Dentistry, University of Taubate, Taubate, SP, Brazil
| | | | - Rafael Pino Vitti
- School of Dentistry, University of Taubate, Taubate, SP, Brazil. .,School of Dentistry, Herminio Ometto University Center, Av. Dr. Maximiliano Baruto, 500, Araras, SP, CEP: 13607-339, Brazil.
| |
Collapse
|
47
|
de Carvalho MA, Lazari-Carvalho PC, Polonial IF, de Souza JB, Magne P. Significance of immediate dentin sealing and flowable resin coating reinforcement for unfilled/lightly filled adhesive systems. J ESTHET RESTOR DENT 2021; 33:88-98. [PMID: 33404184 DOI: 10.1111/jerd.12700] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 12/14/2020] [Indexed: 11/27/2022]
Abstract
BACKGROUND Immediate dentin sealing implies applying an adhesive system to dentin directly after tooth preparation, before impression. The technique is universal (inlays, onlays, veneers, crowns) and well documented clinically and experimentally. Different types of dentin bonding agents (DBAs) are available on the market. Major differences lie in the thickness of the hybrid layer and overlaying adhesive resin (filled vs. unfilled/lightly filled adhesives). OBJECTIVE The objective of this work is to provide precise clinical instructions and present new experimental data about the bond strength of five DBAs (Optibond FL, Scotchbond MP, Single Bond Plus, Clearfil SE Bond, and Scotchbond Universal) used conventionally (dentin sealed at the time of restoration delivery) or with immediate dentin sealing, as well as with an additional flowable resin coating. METHODS Seventy-five human molars were selected, restored/tested according the microtensile bond strength method. Fifteen groups (n=5) were obtained from the combination of the five DBAs and three application modes: delayed dentin sealing, immediate dentin sealing and immediate dentin sealing with flowable resin coating. RESULTS It appears that immediate dentin sealing was confirmed to significantly improve the bond strength of all tested adhesives. The use of a flowable resin coating reinforcement after immediate dentin sealing increased the microtensile bond strength of all unfilled/lightly filled adhesives (from 233% of increase for ScotchBond MP, up to 560% for Clearfil SE Bond) and maintained the performance of the 3-step golden standard adhesive. Optibond FL used with (52.51 MPa) or without (54.75 MPa) additional flowable resin coating and Clearfil SE Bond (45.64 MPa) used with flowable resin coating provided the best results. CLINICAL SIGNIFICANCE The original immediate dentin sealing (IDS) technique implies the use of a filled DBA. With unfilled/lightly filled adhesives, it is suggested to reinforce IDS with an additional flowable resin coating. This seems especially paramount to the performance of simplified adhesive systems to protect the thin bonding interface from oxygen inhibition and preserve IDS layer during predelivery cleaning of the preparation. The clinical reinforcement of unfilled/lightly filled IDS with flowable resin composite is encouraged for more predictable bonding.
Collapse
Affiliation(s)
| | | | - Isabella Fonseca Polonial
- Department of Prevention and Oral Rehabilitation, School of Dentistry, University of Goiás, Goiânia, Brazil
| | - João Batista de Souza
- Department of Prevention and Oral Rehabilitation, School of Dentistry, University of Goiás, Goiânia, Brazil
| | - Pascal Magne
- The Don & Sybil Harrington Professor of Esthetic Dentistry, Division of Restorative Sciences, Ostrow School of Dentistry, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
48
|
Maaßen M, Wille S, Kern M. Bond strength of adhesive luting systems to human dentin and their durability. J Prosthet Dent 2021; 125:182-188. [DOI: 10.1016/j.prosdent.2019.07.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 07/19/2019] [Accepted: 07/19/2019] [Indexed: 11/26/2022]
|
49
|
Almutairi B, Alkahtany MF, Almadi KH, Hussain M, Abduljabbar T. Adhesive strength of bioactive resin for endodontic tooth build up to dentin treated with conventional and contemporary treatments. Photodiagnosis Photodyn Ther 2020; 33:102159. [PMID: 33373743 DOI: 10.1016/j.pdpdt.2020.102159] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Revised: 12/14/2020] [Accepted: 12/21/2020] [Indexed: 12/28/2022]
Abstract
AIM The aim of present ex-vivo study was to assess and evaluate the influence of alternative dentinal conditioning methods- Er,Cr:YSGG (ECL) and Photodynamic therapy (PDT) in comparison to traditional etching regimes- Self Etch Resin (SER) and total etch and rinse (TER) on the bond values of Bioactive restorative material (BA) and Multicore (MC) bulk filled resin composite restorations. MATERIAL AND METHODS Eighty caries free mandibular molars were disinfected and embedded in acrylic resin up to Cemento enamel junction (CEJ). Buccal surfaces of all samples were grounded to depth of 2 mm. Specimens were divided into eight groups (n = 20) based on surface treatment received. Samples in group 1 and 2 conditioned with ECYL, group 3 and 4 pre-treated with methylene blue photosensitizer (MBP), group 5 and 6 surfaces conditioned with TER and samples in group 7 and 8 conditioned with SER. Dentin bonding agent was applied and samples of group 1, 3, 5 and 7 were bonded with BA and 2,4,6,8 bonded to MC. Samples were placed in universal testing machine for SBS testing. Data was assessed using analysis of variance (ANOVA) and Tukey multiple comparisons test. RESULTS Specimens in group 6 treated with TER and bonded with MC demonstrated maximum SBS (19.61 ± 0.587 MPa). Whereas, group 3 dentin conditioned to MBP and bonded to BA displayed lowest bond values (12.01 ± 0.892 MPa). Samples in group 3 and group 4 dentin treated with MBP bonded to MC (13.68 ± 0.221 MPa) and BA (12.01 ± 0.892 MPa) displayed comparable bond integrity (p > 0.05) CONCLUSION: Dentin pre-treated with TER still remains the gold standard. ECYL as an alternative approach to condition dentin has shown potential and can be recommended in clinical settings. MC as bulk fill composite is recommended over BA irrespective of dentine conditioning technique. MBP as dentin conditioner needs further investigation.
Collapse
Affiliation(s)
- Basil Almutairi
- Department of Restorative Dentistry, Division of Operative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| | - Mazen F Alkahtany
- Department of Restorative Dental Science, Division of Endodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| | - Khalid H Almadi
- Department of Restorative Dental Science, Division of Endodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| | - Mudassir Hussain
- Department of Community and Preventive Dentistry, Karachi Medical and Dental College, Karachi, Pakistan.
| | - Tariq Abduljabbar
- Prosthetic Dental Science Department, College of Dentistry, King Saud University, P. O. Box 60169, Riyadh, 11545, Saudi Arabia.
| |
Collapse
|
50
|
Dačić S, Miljković M, Mitić A, Radenković G, Anđelković-Apostolović M, Jovanović M. Influence of etching mode and composite resin type on bond strength to dentin using universal adhesive system. Microsc Res Tech 2020; 84:1212-1219. [PMID: 33354799 DOI: 10.1002/jemt.23680] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 12/03/2020] [Accepted: 12/10/2020] [Indexed: 11/10/2022]
Abstract
Adhesive bond strength at the composite/dentin interface is influenced by various factors, including the etching mode and composite resin type. The purpose of this study was to evaluate the influence of the total-etch and self-etch mode on the microtensile bond strength (μTBS) of conventional and bulk-fill composite to dentin, using the universal adhesive system. Sixty non-carious human teeth were sectioned parallel to their longitudinal axis, using a low-speed diamond saw to obtain a flat dentin surface. According to the etching technique and composite resin type used, teeth were randomly divided into four different groups (n = 15): TC (total-etch/conventional composite), TB (total-etch/bulk-fill composite), SC (self-etch/conventional composite), and SB (self-etch/bulk-fill composite). Cylindric composite build-ups were made with 3M Filtek Z250 and 3M Filtek Bulkfill Posterior, using a plastic mold, 4 mm in diameter and 4 mm in height. The specimens were subjected to the μTBS test in a universal testing machine and failure force was recorded. Failure modes were determined using stereoscopic and scanning electron microscopy. Data were analyzed using the two-way ANOVA and Student's t test. The μTBS was significantly affected by the etching technique. A significant statistical difference was determined between total-etch and self-etch groups, irrespective of the composite resin type used. Higher bond strength was obtained in total-etch groups. The μTBS was not affected by the composite resin type. No significant statistical difference was determined between the conventional and bulk-fill groups, irrespective of the etching-mode.
Collapse
Affiliation(s)
- Stefan Dačić
- Department of Restorative Dentistry and Endodontics, Dental Clinic, Faculty of Medicine, University of Niš, Niš, Serbia
| | - Milan Miljković
- Research Centre for Biomedicine, Faculty of Medicine, University of Niš, Niš, Serbia
| | - Aleksandar Mitić
- Department of Restorative Dentistry and Endodontics, Dental Clinic, Faculty of Medicine, University of Niš, Niš, Serbia
| | - Goran Radenković
- Laboratory for Testing Materials and Machinery, Faculty of Mechanical Engineering, University of Niš, Niš, Serbia
| | | | - Milica Jovanović
- Department of Prosthodontics, Faculty of Medical Sciences, University of Kragujevac, Kragujevac, Serbia
| |
Collapse
|