1
|
Mancim-Imbriani MJ, Duarte JL, Di Filippo LD, Durão LPL, Chorilli M, Palomari Spolidorio DM, Maquera-Huacho PM. Formulation of a Novel Hesperetin-Loaded Nanoemulsion and Its Promising Effect on Osteogenesis. Pharmaceutics 2024; 16:698. [PMID: 38931821 PMCID: PMC11206411 DOI: 10.3390/pharmaceutics16060698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Revised: 05/16/2024] [Accepted: 05/17/2024] [Indexed: 06/28/2024] Open
Abstract
Alternative therapies associating natural products and nanobiotechnology show new perspectives on controlled drug release. In this context, nanoemulsions (NEs) present promising results for their structural design and properties. Hesperetin (HT), a flavonoid mainly found in citrus fruits, presents highlighted bone benefits. In this context, we developed a hesperetin-loaded nanoemulsion (HT-NE) by sonication method and characterized it by dynamic light scattering, analyzing its encapsulation efficiency, and cumulative release. The biocompatibility in human osteoblasts Saos-2-like was evaluated by the cytotoxicity assay and IC50. Then, the effects of the HT-NE on osteogenesis were evaluated by the cellular proliferation, calcium nodule formation, bone regulators gene expression, collagen quantification, and alkaline phosphatase activity. The results showed that the formulation presented ideal values of droplet size, polydispersity index, and zeta potential, and the encapsulation efficiency was 74.07 ± 5.33%, showing a gradual and controlled release. Finally, HT-NE was shown to be biocompatible and increased cellular proliferation, and calcium nodule formation, regulated the expression of Runx2, ALPL, and TGF-β genes, and increased the collagen formation and alkaline phosphatase activity. Therefore, the formulation of this NE encapsulated the HT appropriately, allowing the increasing of its effects on mechanisms to improve or accelerate the osteogenesis process.
Collapse
Affiliation(s)
- Maria Júlia Mancim-Imbriani
- Department of Diagnosis and Surgery, São Paulo State University (UNESP), School of Dentistry, Araraquara CEP 14801-385, São Paulo, Brazil; (M.J.M.-I.); (L.P.L.D.)
- Department of Physiology and Pathology, São Paulo State University (UNESP), School of Dentistry, Araraquara CEP 14801-385, São Paulo, Brazil;
| | - Jonatas Lobato Duarte
- Department of Drugs and Medicines, São Paulo State University (UNESP), School of Pharmaceutical Sciences, Araraquara CEP 14800-903, São Paulo, Brazil; (J.L.D.); (L.D.D.F.); (M.C.)
| | - Leonardo Delello Di Filippo
- Department of Drugs and Medicines, São Paulo State University (UNESP), School of Pharmaceutical Sciences, Araraquara CEP 14800-903, São Paulo, Brazil; (J.L.D.); (L.D.D.F.); (M.C.)
| | - Letícia Pereira Lima Durão
- Department of Diagnosis and Surgery, São Paulo State University (UNESP), School of Dentistry, Araraquara CEP 14801-385, São Paulo, Brazil; (M.J.M.-I.); (L.P.L.D.)
- Department of Physiology and Pathology, São Paulo State University (UNESP), School of Dentistry, Araraquara CEP 14801-385, São Paulo, Brazil;
| | - Marlus Chorilli
- Department of Drugs and Medicines, São Paulo State University (UNESP), School of Pharmaceutical Sciences, Araraquara CEP 14800-903, São Paulo, Brazil; (J.L.D.); (L.D.D.F.); (M.C.)
| | - Denise Madalena Palomari Spolidorio
- Department of Physiology and Pathology, São Paulo State University (UNESP), School of Dentistry, Araraquara CEP 14801-385, São Paulo, Brazil;
| | - Patricia Milagros Maquera-Huacho
- Department of Diagnosis and Surgery, São Paulo State University (UNESP), School of Dentistry, Araraquara CEP 14801-385, São Paulo, Brazil; (M.J.M.-I.); (L.P.L.D.)
- Department of Physiology and Pathology, São Paulo State University (UNESP), School of Dentistry, Araraquara CEP 14801-385, São Paulo, Brazil;
| |
Collapse
|
2
|
Duan X, Yang Y, Zhang T, Zhu B, Wei G, Li H. Research progress of metal biomaterials with potential applications as cardiovascular stents and their surface treatment methods to improve biocompatibility. Heliyon 2024; 10:e25515. [PMID: 38375258 PMCID: PMC10875388 DOI: 10.1016/j.heliyon.2024.e25515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 01/23/2024] [Accepted: 01/29/2024] [Indexed: 02/21/2024] Open
Abstract
Facing the growing issue of cardiovascular diseases, metallic materials with higher tensile strength and fatigue resistance play an important role in treating diseases. This review lists the advantages and drawbacks of commonly used medical metallic materials for vascular stents. To avoid post-procedural threats such as thrombosis and in-stent restenosis, surface treatments, and coating methods have been used to further improve the biocompatibility of these materials. Surface treatments including laser, plasma treatment, polishing, oxidization, and fluorination can improve biocompatibility by modifying the surface charges, surface morphology, and surface properties of the material. Coating methods based on polymer coatings, carbon-based coatings, and drug-functional coatings can regulate the surface properties, and also serve as an effective barrier to the interaction of metallic biomaterial surfaces with biomolecules, which can be used to improve corrosion resistance and stability, as well as improve their biocompatibility. Biocompatibility serves as the most fundamental property of cardiovascular stents, and maintaining the excellent and stable biocompatibility of cardiovascular stent surfaces is a current research bottleneck. Few reviews have been published on metallic biomaterials as cardiovascular stents and their surface treatments. For the purpose of advancing research on cardiovascular stents, common metal biomaterials, surface treatment methods, and coating methods to improve biocompatibility and comprehensive properties of the materials are described in this review. Finally, we suggest future directions for stent development, including continuously improving the durability and stability of permanent stents, accelerating the development of biodegradable stents, and strengthening feedback to improve the safety and reliability of cardiovascular stents.
Collapse
Affiliation(s)
- Xuejia Duan
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
- Division of Chemistry and Analytical Science, National Institute of Metrology, Beijing, China
| | - Yumeng Yang
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
| | - Tianji Zhang
- Division of Chemistry and Analytical Science, National Institute of Metrology, Beijing, China
- Key Laboratory of Chemical Metrology and Applications on Nutrition and Health for State Market Regulation, China
| | - Benfeng Zhu
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
| | - Guoying Wei
- College of Materials and Chemistry, China Jiliang University, Hangzhou, Zhejiang 310018, China
| | - Hongmei Li
- Division of Chemistry and Analytical Science, National Institute of Metrology, Beijing, China
- Key Laboratory of Chemical Metrology and Applications on Nutrition and Health for State Market Regulation, China
| |
Collapse
|
3
|
Pera F, Kim BC, Pesce P, Menini M, Troiano G, Zhurakivska K. Diamond-Like Carbon Coating Reduces Connection Screw Head Stripping After Multiple Tightening Instances. J ORAL IMPLANTOL 2024; 50:45-49. [PMID: 38579112 DOI: 10.1563/aaid-joi-d-23-00072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2024]
Abstract
The stability of implant-abutment joint is fundamental for the long-term success of implant rehabilitation. The screw loosening, fracture, and head deformation are among the most common mechanical complications. Several surface treatments of titanium screws have been proposed to improve their resistance and stability. Diamond-like carbon (DLC) coating of the materials is widely used to increase their wear resistance and durability. The present study aimed to evaluate the effect of carbon fiber coating on the screw head on screw removal torque and screw head stripping. One hundred titanium implant screws were used, 50 without coating (Group 1) and 50 with DLC coating of the screw head (Group 2). Each screw was tightened with a torque of 25 Ncm and unscrewed 10 times. The removal torque was measured with a digital cap torque tester for each loosening. Optical 3d measurement of the screw head surface was performed by a fully automatic machine before and after multiple tightening to investigate surface modifications. The reverse torque values decreased with repeated tightening and loosening cycles in both groups without significant differences (P > .05). Optical measurements of surface dimensions revealed average changes of 0.0357 mm in Group 1 and 0.02312 mm in Group 2, which resulted to be statistically significant (P < .001). The DLC coating of the retention screw head can prevent its distortion and wear, especially after multiple tightening.
Collapse
Affiliation(s)
- Francesco Pera
- Department of Surgical Sciences, CIR Dental School, University of Turin, Turin, Italy
| | - Byung Chan Kim
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| | - Paolo Pesce
- Department of Surgical Sciences, University of Genova, Genova, Italy
| | - Maria Menini
- Department of Surgical Sciences, University of Genova, Genova, Italy
| | - Giuseppe Troiano
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| | - Khrystyna Zhurakivska
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| |
Collapse
|
4
|
Maquera-Huacho PM, de Carvalho GG, Jafelicci M, Marcantonio E, Spolidorio DMP. Physical-chemical influences and cell behavior of natural compounds on titanium dental surfaces. Braz Dent J 2023; 34:53-62. [PMID: 38133473 PMCID: PMC10759949 DOI: 10.1590/0103-6440202305582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 10/30/2023] [Indexed: 12/23/2023] Open
Abstract
The present study evaluated the influence of carvacrol, terpinene-4-ol, and chlorhexidine on the physical-chemical properties of titanium surfaces, cell viability, proliferation, adhesion, and spreading of fibroblasts and osteoblasts in vitro. Titanium surfaces (Ti) were treated with Carvacrol (Cvc), Terpinen-4-ol (T4ol), Chlorhexidine (CHX), DMSO, and ultrapure water (Control group). Physical-chemical modifications were evaluated by surface wettability, the surface free energy (SFE) calculated from the contact angle values using the Owens-Wendt-Rabel-Kaeble (OWRK) equation, scanning electron microscopy (SEM) and energy dispersive spectrometry probe (EDS) system. Cells were seeded onto Ti-treated surfaces and incubated for 24 h and 72 h, then evaluated by Alamar blue assay and fluorescence microscopy. Surfaces treated with Cvc and T4ol showed the presence of Na, O, and Cl. All surfaces showed hydrophilic characteristics and SFE values between 5.5 mN/m and 3.4 mN/m. On the other hand, EDS peaks demonstrated the presence of O and Cl after CHX treatment. A reduction of cell viability and adhesion was noted on titanium surfaces treated with CHX after 24 and 72h. In conclusion, the results indicate that the decontamination with Cvc and T4ol on Ti surfaces does not alter the surface proprieties and allows an adequate interaction with cells involved in the re-osseointegration process such as fibroblasts and osteoblasts.
Collapse
Affiliation(s)
- Patricia Milagros Maquera-Huacho
- Department of Physiology and Pathology, School of Dentistry, São Paulo State University(Unesp), Araraquara, SP, Brazil
- Department of Diagnosis and Surgery, School of Dentistry, São Paulo State University(Unesp), Araraquara, São Paulo, Brazil
| | - Gabriel Garcia de Carvalho
- Department of Physiology and Pathology, School of Dentistry, São Paulo State University(Unesp), Araraquara, SP, Brazil
- Department of Diagnosis and Surgery, School of Dentistry, São Paulo State University(Unesp), Araraquara, São Paulo, Brazil
| | - Miguel Jafelicci
- Institute of Chemistry, Laboratory of Magnetic Materials and Colloids, São Paulo State University(Unesp), Araraquara, SP, Brazil
| | - Elcio Marcantonio
- Department of Diagnosis and Surgery, School of Dentistry, São Paulo State University(Unesp), Araraquara, São Paulo, Brazil
| | - Denise Madalena Palomari Spolidorio
- Department of Physiology and Pathology, School of Dentistry, São Paulo State University(Unesp), Araraquara, SP, Brazil
- Department of Diagnosis and Surgery, School of Dentistry, São Paulo State University(Unesp), Araraquara, São Paulo, Brazil
| |
Collapse
|
5
|
Sheng D, Zhang L, Shang H, Guo B, Li Y. The Surface of a PMP Hollow Fiber Membrane Was Modified with a Diamond-like Carbon Film to Enhance the Blood Compatibility of an Artificial Lung Membrane. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:13258-13266. [PMID: 37671981 DOI: 10.1021/acs.langmuir.3c01711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/07/2023]
Abstract
The contact between the blood and the surface of medical materials causes a series of rejection reactions. In this process, the plasma protein is adsorbed to the surface of materials within seconds and binds to glycoprotein receptors on platelets, causing platelet activation, coagulation cascade, and complement activation to form thrombus, which greatly limits the application of medical materials. In our work, the surface of poly(4-methyl-1-pentene) hollow fiber membranes (PMP HFMs) was coated with a diamond-like carbon (DLC) film by the ion plating method. The blood compatibility of the DLC coating was evaluated by protein adsorption, platelet adhesion, clotting time, red blood cell (RBCs) hemolysis, dynamic coagulation, and extracorporeal blood circulation tests. Compared with the unmodified PMP membrane, the DLC film could effectively reduce protein adsorption and platelet adhesion and prolong the coagulation time. The DLC coating showed BSA adsorption of as low as 0.53 μg/cm2 as well as a long activated partial thromboplastin time (APTT) value of 71.84 s. Furthermore, the PMP membrane modified with the DLC coating was used for extracorporeal blood circulation without thrombosis forming within 28 days. The DLC coating is one of the most promising medical coatings as an artificial lung membrane in extracorporeal membrane oxygenation (ECMO) equipment.
Collapse
Affiliation(s)
- Donghai Sheng
- State Key Laboratory of Tribology in Advanced Equipment, Tsinghua University, Beijing 100084, China
| | - Lin Zhang
- State Key Laboratory of Tribology in Advanced Equipment, Tsinghua University, Beijing 100084, China
| | - Hongfei Shang
- State Key Laboratory of Tribology in Advanced Equipment, Tsinghua University, Beijing 100084, China
| | - Baoming Guo
- State Key Laboratory of Tribology in Advanced Equipment, Tsinghua University, Beijing 100084, China
| | - Yuan Li
- Central Laboratory of Yongchuan Hospital, Chongqing Medical University, Chongqing 402160, China
| |
Collapse
|
6
|
Banu Raza F, Vijayaragavalu S, Kandasamy R, Krishnaswami V, Kumar V A. Microbiome and the inflammatory pathway in peri-implant health and disease with an updated review on treatment strategies. J Oral Biol Craniofac Res 2023; 13:84-91. [PMID: 36504486 PMCID: PMC9730223 DOI: 10.1016/j.jobcr.2022.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 08/30/2022] [Accepted: 11/25/2022] [Indexed: 12/04/2022] Open
Abstract
Crestal bone preservation around the dental implant for aesthetic and functional success is widely researched and documented over a decade. Several etiological factors were put forth for crestal bone loss; of which biofilm plays a major role. Biofilm is formed by the colonization of wide spectra of bacteria inhabited around dental implants. Bacterial adherence affects the regulators of bone growth and an early intervention preserves the peri-implant bone. Primary modes of therapy stated in early literature were either prevention or treatment of infection caused by biofilm. This narrative review overviews the microbiome during different stages of peri-implant health, the mechanism of bone destruction, and the expression of the biomarkers at each stage. Microbial contamination and the associated biomarkers varied depending on the stage of peri-implant infection. The comprehensive review helps in formulating a research plan, both in diagnostics and treatment aspects in improving peri-implant health.
Collapse
Key Words
- Antibiotics
- Biomarkers
- CD14, Cluster of Differentiation 14
- CSF, Colony-Stimulating Factor
- Gene expression
- IL, Interleukins
- MMP 8, Matrix MetalloProteinase 8
- Microbiota
- OPG, Osteoprotegerin
- PSMB 2, Proteasome subunit beta type-2
- Peri-implant
- RANK, Receptor Activator of Nuclear factor Kappa-Β
- RANKL, Receptor Activator of Nuclear factor Kappa-ΒLigand
- TIMP, Tissue inhibitor of Metalloproteinase
- TNF, Tumor Necrosis Factor
- TWEAK, TNF-related weak inducer of apoptosis
- VEGF, Vascular Endothelial Growth Factor
- sRANKL, soluble Receptor Activator of Nuclear Factor-κB Ligand
Collapse
Affiliation(s)
- Fathima Banu Raza
- Department of Prosthodontics, Faculty of Dental Sciences, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India
| | | | - Ruckmani Kandasamy
- Centre for Excellence in Nanobio Translational REsearch (CENTRE), Department of Pharmaceutical Technology, University College of Engineering, Anna University, BIT Campus, Tiruchirappalli, Tamil Nadu, India
| | - Venkateshwaran Krishnaswami
- Centre for Excellence in Nanobio Translational REsearch (CENTRE), Department of Pharmaceutical Technology, University College of Engineering, Anna University, BIT Campus, Tiruchirappalli, Tamil Nadu, India
| | - Anand Kumar V
- Department of Prosthodontics, Faculty of Dental Sciences, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India
- Corresponding author. Department of Prosthodontics, Faculty of Dental Sciences, SRIHER (DU), Porur, Chennai, Tamil Nadu, India.
| |
Collapse
|
7
|
Hoque ME, Showva NN, Ahmed M, Rashid AB, Sadique SE, El-Bialy T, Xu H. Titanium and titanium alloys in dentistry: current trends, recent developments, and future prospects. Heliyon 2022; 8:e11300. [PMID: 36387463 PMCID: PMC9640965 DOI: 10.1016/j.heliyon.2022.e11300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 09/26/2022] [Accepted: 10/24/2022] [Indexed: 11/06/2022] Open
Abstract
Many implant materials have been used in various dental applications depending on their efficacy and availability. A dental implant must possess the required characteristics, such as biocompatibility, corrosion & wear resistance, adequate mechanical properties, osseointegration, etc., to ensure its safe and optimum use. This review analyzes various aspects of titanium (Ti) and Ti alloys, including properties, manufacturing processes, surface modifications, applications as dental implants, and limitations. In addition, it also presents a perception of recent advances in Ti-based implant materials and the futuristic development of innovative dental implants.
Collapse
Affiliation(s)
- Md Enamul Hoque
- Department of Biomedical Engineering, Military Institute of Science and Technology, Dhaka, Bangladesh
| | - Nazmir-Nur Showva
- Department of Biomedical Engineering, Military Institute of Science and Technology, Dhaka, Bangladesh
| | - Mansura Ahmed
- Department of Biomedical Engineering, Military Institute of Science and Technology, Dhaka, Bangladesh
| | - Adib Bin Rashid
- Department of Industrial and Production Engineering, Military Institute of Science and Technology, Dhaka, Bangladesh
| | - Sarder Elius Sadique
- College of Information Technology and Engineering, Marshall University, West Virginia, USA
| | - Tarek El-Bialy
- Department of Dentistry & Dental Hygiene, University of Alberta, Alberta, Canada
| | - Huaizhong Xu
- Department of Biobased Materials Science, Kyoto Institute of Technology (KIT), Sakyoku, Kyoto City, Japan
| |
Collapse
|
8
|
Wang X, Huang J, Guo Z. Overview of the development of slippery surfaces: Lubricants from presence to absence. Adv Colloid Interface Sci 2022; 301:102602. [PMID: 35085985 DOI: 10.1016/j.cis.2022.102602] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 01/07/2022] [Accepted: 01/11/2022] [Indexed: 12/17/2022]
Abstract
The superhydrophobic surfaces inspired by the lotus have excellent performances and are known for their low contact angle hysteresis and smooth surfaces. However, there are still some problems, such as the unstable structure, poor durability, high product cost and so on that need to be improved. Those issues can be avoided via liquid-infused surfaces(LIS), which are inspired by Nepenthes and consist of a mico-nano structured substrate and a smooth continuous atomic-grade lubricant. Compared with superhydrophobic surfaces, LIS not only achieves the same hydrophobic properties but also has smaller contact angle hysteresis, smoother surface, more stable structure and lower preparation cost. Although the existence of a lubricant layer improves the performance of the material, it also leaves a hidden danger, which is easy to lose and leads to the deterioration of the durability of the material. Therefore, the lubricant-free slipper materials have attracted more and more attention in recent years due to their low volatility, good durability and excellent lubrication performance. In this review, the types of LIS lubricants and their physicochemical properties were summarized at the beginning and then the applications of LIS in various fields were introduced. At the end of this paper, some solid lubricants and their applications were described, and the future development prospects of LIS lubricants also were expected.
Collapse
Affiliation(s)
- Xiaobo Wang
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China
| | - Jinxia Huang
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China.
| | - Zhiguang Guo
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China.
| |
Collapse
|
9
|
Antibacterial Effects of Modified Implant Abutment Surfaces for the Prevention of Peri-Implantitis-A Systematic Review. Antibiotics (Basel) 2021; 10:antibiotics10111350. [PMID: 34827288 PMCID: PMC8615005 DOI: 10.3390/antibiotics10111350] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 10/28/2021] [Accepted: 10/31/2021] [Indexed: 12/27/2022] Open
Abstract
The aim of the present study was to systematically review studies investigating antibacterial implant abutment surfaces or coatings, which may suppress bacterial growth to prevent plaque-induced peri-implant inflammatory disease. Data were collected after identification of case, assay/laboratory procedure, predicate/reference standard and outcome (CAPO). Seven hundred and twenty (720) records were identified through data base searching. After screening nine publications fulfilled inclusion criteria and were included. The following surfaces/coatings showed antibacterial properties: Electrochemical surface modification of titanium by the anodic spark deposition technique; doxycycline coating by cathodic polarization; silver coating by DC plasma sputter; titanium nitride; zirconium nitride and microwave assistant nano silver coating. Since the current state of the literature is rather descriptive, a meta-analysis was not performed. While several abutment coatings showed to have antibacterial capacity, some of them also influenced the behavior of investigated human cells. None of the studies investigated the long-term effect of surface modifications. Since surface changes are the main contributing factor in the development of antibacterial effects, the biodegradation behavior must be characterized to understand its durability. To date there is no effective structure, material or strategy to avoid peri-implant inflammation used as clinical routine. Furthermore, clinical studies are scarce.
Collapse
|
10
|
Shokeen B, Zamani L, Zadmehr S, Pouraghaie S, Ozawa R, Yilmaz B, Lilak S, Sharma S, Ogawa T, Moshaverinia A, Lux R. Surface Characterization and Assessment of Biofilm Formation on Two Titanium-Based Implant Coating Materials. FRONTIERS IN DENTAL MEDICINE 2021. [DOI: 10.3389/fdmed.2021.695417] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Implant-related oral diseases such as peri-implantitis and peri-mucositis are largely initiated by bacterial colonization on artificial implant surfaces. Therefore, implant and abutment material characteristics that minimize bacterial attachment and subsequent biofilm formation are important factors in reducing the risk of infection-related implant failure. This study compares the properties of two different titanium-based implant coating materials, titanium nitride (TiN) and titanium carbon nitride (TiCN). Surface hydrophilicity/ hydrophobicity and roughness were evaluated via contact angle measurements and surface profiling with white light interferometry, respectively. TiN-coated surfaces were hydrophobic according to its contact angle higher than 72.7°, whereas TiCN-coated surfaces were hydrophilic with its contact angle of 53.6°. The average roughness (Ra) was greater for TiCN than TiN with the root mean square roughness (Rq) being significantly higher. These findings are in contrast to the common understanding for titanium-based materials that surface roughness and hydrophobicity are positively correlated. A well-established saliva-based oral microbial biofilm model was employed to compare bacterial attachment and biofilm formation on TiN and TiCN. Growth conditions included relevant host components such as blood as well as the presence or absence of dietary carbohydrates. The accumulated biomass was measured by crystal violet staining and the bacterial community profiles of the attached biofilms were determined via 16S rRNA gene microbiome sequencing at different time points over a 7-day period. At all time points, TiCN showed significantly less bacterial attachment and biofilm formation compared to TiN. This implied the importance of the hydrophilic state over surface roughness as parameter for the prevention of oral microbial attachment. Although, the biofilm community composition was very similar on both materials, environmental growth conditions resulted in significantly different bacterial profiles independent of the surface. In conclusion, TiCN coating produced a unique titanium surface which is rougher but more hydrophilic. TiCN-coated surfaces exhibited reduced bacterial attachment and biofilm formation in comparison to TiN coating. This coating technique can be further explored to improve implant and abutment success.
Collapse
|
11
|
Abstract
The topic of titanium alloys for dental implants has been reviewed. The basis of the review was a search using PubMed, with the large number of references identified being reduced to a manageable number by concentrating on more recent articles and reports of biocompatibility and of implant durability. Implants made mainly from titanium have been used for the fabrication of dental implants since around 1981. The main alloys are so-called commercially pure titanium (cpTi) and Ti-6Al-4V, both of which give clinical success rates of up to 99% at 10 years. Both alloys are biocompatible in contact with bone and the gingival tissues, and are capable of undergoing osseointegration. Investigations of novel titanium alloys developed for orthopaedics show that they offer few advantages as dental implants. The main findings of this review are that the alloys cpTi and Ti-6Al-4V are highly satisfactory materials, and that there is little scope for improvement as far as dentistry is concerned. The conclusion is that these materials will continue to be used for dental implants well into the foreseeable future.
Collapse
|
12
|
Al Ankily M, Makkeyah F, Bakr M, Shamel M. Effect of different scaling methods and materials on the enamel surface topography: An in vitro SEM study. J Int Oral Health 2020. [DOI: 10.4103/jioh.jioh_121_20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
13
|
Perumal G, Chakrabarti A, Grewal HS, Pati S, Singh S, Arora HS. Enhanced antibacterial properties and the cellular response of stainless steel through friction stir processing. BIOFOULING 2019; 35:187-203. [PMID: 30913919 DOI: 10.1080/08927014.2019.1584794] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 02/05/2019] [Accepted: 02/10/2019] [Indexed: 06/09/2023]
Abstract
Biofilm related bacterial infection is one of the primary causes of implant failure. Limiting bacterial adhesion and colonization of pathogenic bacteria is a challenging task in health care. Here, a highly simplistic processing technique for imparting antibacterial properties on a biomedical grade stainless steel is demonstrated. Low-temperature high strain-rate deformation achieved using submerged friction stir processing resulted in a nearly single phase ultra-fine grain structure. The processed stainless steel demonstrated improved antibacterial properties for both Gram-positive and Gram-negative bacteria, significantly impeding biofilm formation during the in vitro study. Also, the processed stainless steel showed better compatibility with human fibroblasts manifested through apparent cell spreading and proliferation. The substantial antibacterial properties of the processed steel are explained in terms of the favorable electronic characteristics of the metal-oxide and by using classical Derjaguin-Landau-Verwey-Overbeek (DLVO) and the extended DLVO (XDLVO) approach at the cell-substrate interface.
Collapse
Affiliation(s)
- Gopinath Perumal
- a Surface Science and Tribology Laboratory, School of Mechanical Engineering , Shiv Nadar University , Greater Noida , Uttar Pradesh , India
| | - Amrita Chakrabarti
- b Department of Life Sciences, School of Natural Sciences , Shiv Nadar University , Greater Noida , Uttar Pradesh , India
| | - Harpreet S Grewal
- a Surface Science and Tribology Laboratory, School of Mechanical Engineering , Shiv Nadar University , Greater Noida , Uttar Pradesh , India
| | - Soumya Pati
- b Department of Life Sciences, School of Natural Sciences , Shiv Nadar University , Greater Noida , Uttar Pradesh , India
| | - Shailja Singh
- b Department of Life Sciences, School of Natural Sciences , Shiv Nadar University , Greater Noida , Uttar Pradesh , India
- c Special Center for Molecular Medicine , Jawaharlal Nehru University , New Delhi , India
| | - Harpreet S Arora
- a Surface Science and Tribology Laboratory, School of Mechanical Engineering , Shiv Nadar University , Greater Noida , Uttar Pradesh , India
| |
Collapse
|
14
|
Rahmati M, Mozafari M. Biological Response to Carbon-Family Nanomaterials: Interactions at the Nano-Bio Interface. Front Bioeng Biotechnol 2019; 7:4. [PMID: 30729107 PMCID: PMC6351449 DOI: 10.3389/fbioe.2019.00004] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 01/04/2019] [Indexed: 02/06/2023] Open
Abstract
During the last few decades, several studies have suggested that carbon-based nanomaterials, owing to their unique properties, could act as promising candidates in biomedical engineering application. Wide-ranging research efforts have investigated the cellular and molecular responses to carbon-based nanomaterials at the nano-bio interfaces. In addition, a number of surface functionalization strategies have been introduced to improve their safety profile in the biological environment. The present review discusses the general principles of immunological responses to nanomaterials. Then, it explains essential physico-chemical properties of carbon-familynanomaterials, including carbon nanotubes (CNTs), graphene, fullerene, carbon quantum dots (CDs), diamond-like carbon (DLC), and mesoporous carbon biomaterials (MCNs), which significantly affect the immunological cellular and molecular responses at the nano-bio interface. The discussions also briefly highlight the recent studies that critically investigated the cellular and molecular responses to various carbon-based nanomaterials. It is expected that the most recent perspective strategies for improving the biological responses to carbon-based nanomaterials can revolutionize their functions in emerging biological applications.
Collapse
Affiliation(s)
- Maryam Rahmati
- Bioengineering Research Group, Nanotechnology and Advanced Materials Department, Materials and Energy Research Center, Tehran, Iran.,Cellular and Molecular Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Masoud Mozafari
- Bioengineering Research Group, Nanotechnology and Advanced Materials Department, Materials and Energy Research Center, Tehran, Iran.,Cellular and Molecular Research Center, Iran University of Medical Sciences, Tehran, Iran.,Department of Tissue Engineering & Regenerative Medicine, Faculty of Advanced Technologies in Medicine, Iran University of Medical Sciences, Tehran, Iran
| |
Collapse
|