1
|
Maruyama S, Takeshima H. Generating Synthetic MR Spectroscopic Imaging Data with Generative Adversarial Networks to Train Machine Learning Models. Magn Reson Med Sci 2024:mp.2023-0125. [PMID: 39010240 DOI: 10.2463/mrms.mp.2023-0125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/17/2024] Open
Abstract
PURPOSE To develop a new method to generate synthetic MR spectroscopic imaging (MRSI) data for training machine learning models. METHODS This study targeted routine MRI examination protocols with single voxel spectroscopy (SVS). A novel model derived from pix2pix generative adversarial networks was proposed to generate synthetic MRSI data using MRI and SVS data as inputs. T1- and T2-weighted, SVS, and reference MRSI data were acquired from healthy brains with clinically available sequences. The proposed model was trained to generate synthetic MRSI data. Quantitative evaluation involved the calculation of the mean squared error (MSE) against the reference and metabolite ratio value. The effect of the location of and the number of the SVS data on the quality of the synthetic MRSI data was investigated using the MSE. RESULTS The synthetic MRSI data generated from the proposed model were visually closer to the reference. The 95% confidence interval (CI) of the metabolite ratio value of synthetic MRSI data overlapped with the reference for seven of eight metabolite ratios. The MSEs tended to be lower in the same location than in different locations. The MSEs among groups of numbers of SVS data were not significantly different. CONCLUSION A new method was developed to generate MRSI data by integrating MRI and SVS data. Our method can potentially increase the volume of MRSI data training for other machine learning models by adding SVS acquisition to routine MRI examinations.
Collapse
Affiliation(s)
- Shuki Maruyama
- Imaging Modality Group, Advanced Technology Research Department, Research and Development Center, Canon Medical Systems Corporation, Otawara, Tochigi, Japan
| | - Hidenori Takeshima
- Advanced Technology Research Department, Research and Development Center, Canon Medical Systems Corporation, Kawasaki, Kanagawa, Japan
| |
Collapse
|
2
|
Weng G, Slotboom J, Schucht P, Ermiş E, Wiest R, Klöppel S, Peter J, Zubak I, Radojewski P. Simultaneous multi-region detection of GABA+ and Glx using 3D spatially resolved SLOW-editing and EPSI-readout at 7T. Neuroimage 2024; 286:120511. [PMID: 38184158 DOI: 10.1016/j.neuroimage.2024.120511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 12/07/2023] [Accepted: 01/04/2024] [Indexed: 01/08/2024] Open
Abstract
GABA+ and Glx (glutamate and glutamine) are widely studied metabolites, yet the commonly used magnetic resonance spectroscopy (MRS) techniques have significant limitations, including sensitivity to B0 and B1+-inhomogeneities, limited bandwidth of MEGA-pulses, high SAR which is accentuated at 7T. To address these limitations, we propose SLOW-EPSI method, employing a large 3D MRSI coverage and achieving a high resolution down to 0.26 ml. Simulation results demonstrate the robustness of SLOW-editing for both GABA+ and Glx against B0 and B1+-inhomogeneities within the range of [-0.3, +0.3] ppm and [40 %, 250 %], respectively. Two protocols, both utilizing a 70 mm thick FOV slab, were employed to target distinct brain regions in vivo, differentiated by their orientation: transverse and tilted. Protocol 1 (n = 11) encompassed 5 locations (cortical gray matter, white matter, frontal lobe, parietal lobe, and cingulate gyrus). Protocol 2 (n = 5) involved 9 locations (cortical gray matter, white matter, frontal lobe, occipital lobe, cingulate gyrus, caudate nucleus, hippocampus, putamen, and inferior thalamus). Quantitative analysis of GABA+ and Glx was conducted in a stepwise manner. First, B1+/B1--inhomogeneities were corrected using water reference data. Next, GABA+ and Glx values were calculated employing spectral fitting. Finally, the GABA+ level for each selected region was compared to the global Glx within the same subject, generating the GABA+/Glx_global ratio. Our findings from two protocols indicate that the GABA+/Glx_global level in cortical gray matter was approximately 16 % higher than in white matter. Elevated GABA+/Glx_global levels acquired with protocol 2 were observed in specific regions such as the caudate nucleus (0.118±0.067), putamen (0.108±0.023), thalamus (0.092±0.036), and occipital cortex (0.091±0.010), when compared to the cortical gray matter (0.079±0.012). Overall, our results highlight the effectiveness of SLOW-EPSI as a robust and efficient technique for accurate measurements of GABA+ and Glx at 7T. In contrast to previous SVS and 2D-MRSI based editing sequences with which only one or a limited number of brain regions can be measured simultaneously, the method presented here measures GABA+ and Glx from any brain area and any arbitrarily shaped volume that can be flexibly selected after the examination. Quantification of GABA+ and Glx across multiple brain regions through spectral fitting is achievable with a 9-minute acquisition. Additionally, acquisition times of 18-27 min (GABA+) and 9-18 min (Glx) are required to generate 3D maps, which are constructed using Gaussian fitting and peak integration.
Collapse
Affiliation(s)
- Guodong Weng
- Institute for Diagnostic and Interventional Neuroradiology, Inselspital, University Hospital and University of Bern, Switzerland; Translational Imaging Center, sitem-insel, Bern, Switzerland.
| | - Johannes Slotboom
- Institute for Diagnostic and Interventional Neuroradiology, Inselspital, University Hospital and University of Bern, Switzerland; Translational Imaging Center, sitem-insel, Bern, Switzerland
| | - Philippe Schucht
- Department of Neurosurgery, Inselspital, University Hospital and University of Bern, Switzerland
| | - Ekin Ermiş
- Department of Radiation Oncology, Inselspital, University Hospital and University of Bern, Switzerland
| | - Roland Wiest
- Institute for Diagnostic and Interventional Neuroradiology, Inselspital, University Hospital and University of Bern, Switzerland; Translational Imaging Center, sitem-insel, Bern, Switzerland
| | - Stefan Klöppel
- University Hospital of Old Age Psychiatry and Psychotherapy, University of Bern, Bern, Switzerland
| | - Jessica Peter
- University Hospital of Old Age Psychiatry and Psychotherapy, University of Bern, Bern, Switzerland
| | - Irena Zubak
- Department of Neurosurgery, Inselspital, University Hospital and University of Bern, Switzerland
| | - Piotr Radojewski
- Institute for Diagnostic and Interventional Neuroradiology, Inselspital, University Hospital and University of Bern, Switzerland; Translational Imaging Center, sitem-insel, Bern, Switzerland
| |
Collapse
|
3
|
Kuribayashi H, Urushibata Y, Imai H, Ahn S, Seethamraju RT, Isa T, Okada T. Quantification of Cerebral Glucose Concentrations via Detection of the H1-α-Glucose Peak in 1 H MRS at 7 T. J Magn Reson Imaging 2024; 59:661-672. [PMID: 37259965 DOI: 10.1002/jmri.28834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 05/14/2023] [Accepted: 05/16/2023] [Indexed: 06/02/2023] Open
Abstract
BACKGROUND Sensitive detection and quantification of cerebral glucose is desired. PURPOSE To quantify cerebral glucose by detecting the H1-α-glucose peak at 5.23 ppm in 1 H magnetic resonance spectroscopy at 7 T. STUDY TYPE Prospective. SUBJECTS Twenty-eight non-fasted healthy subjects (aged 20-28 years). FIELD STRENGTH/SEQUENCE Short echo time stimulated echo acquisition mode (short-TE STEAM) and semi-localized by adiabatic selective refocusing (semi-LASER) at 7 T. ASSESSMENT Single voxel spectra were obtained from the posterior cingulate cortex (27-mL) using a 32-channel head coil. The H1-α-glucose peak in the spectrum with retrospective removal of the residual water peak was fitted using LCModel with a glucose basis set of only the H1-α-glucose peak. Conventional spectral analysis was performed with a glucose basis set of a full spectral pattern of glucose, also. Fitting precision was evaluated with Cramér-Rao lower bounds (CRLBs). The repeatability of glucose quantification via the semi-LASER sequence was tested. STATISTICAL TESTS Paired or Welch's t-test were used for normally distributed values. A P value of <0.05 was considered significant. The repeatability of measures was analyzed using coefficient of variation (CV). RESULTS Removal of the residual water peak improved the flatness and stability of baselines around the H1-α-glucose peak and reduced CRLBs for fitting the H1-α-glucose peak. The semi-LASER sequence was superior to the short-TE STEAM in the higher signal-to-noise ratio of the H1-α-glucose peak (mean ± SD 7.9 ± 2.5, P < 0.001). The conventional analysis overfitted the H1-α-glucose peak. The individual CVs of glucose quantification by detecting the H1-α-glucose peak were smaller than the corresponding CRLBs. DATA CONCLUSION Cerebral glucose concentration is quantitated to be 1.07 mM by detecting the H1-α-glucose peak in the semi-LASER spectra. Despite requiring long scan times, detecting the H1-α-glucose peak allows true glucose quantification free from the influence of overlapping taurine and macromolecule signals. EVIDENCE LEVEL 2 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
| | | | - Hirohiko Imai
- Kyoto University Graduate School of Informatics, Kyoto, Japan
| | - Sinyeob Ahn
- Siemens Medical Solutions, Berkeley, California, USA
| | | | - Tadashi Isa
- Human Brain Research Center, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Tomohisa Okada
- Human Brain Research Center, Kyoto University Graduate School of Medicine, Kyoto, Japan
| |
Collapse
|
4
|
Gudmundson AT, Koo A, Virovka A, Amirault AL, Soo M, Cho JH, Oeltzschner G, Edden RAE, Stark CEL. Meta-analysis and open-source database for in vivo brain Magnetic Resonance spectroscopy in health and disease. Anal Biochem 2023; 676:115227. [PMID: 37423487 PMCID: PMC10561665 DOI: 10.1016/j.ab.2023.115227] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 06/15/2023] [Accepted: 06/26/2023] [Indexed: 07/11/2023]
Abstract
Proton (1H) Magnetic Resonance Spectroscopy (MRS) is a non-invasive tool capable of quantifying brain metabolite concentrations in vivo. Prioritization of standardization and accessibility in the field has led to the development of universal pulse sequences, methodological consensus recommendations, and the development of open-source analysis software packages. One on-going challenge is methodological validation with ground-truth data. As ground-truths are rarely available for in vivo measurements, data simulations have become an important tool. The diverse literature of metabolite measurements has made it challenging to define ranges to be used within simulations. Especially for the development of deep learning and machine learning algorithms, simulations must be able to produce accurate spectra capturing all the nuances of in vivo data. Therefore, we sought to determine the physiological ranges and relaxation rates of brain metabolites which can be used both in data simulations and as reference estimates. Using the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines, we've identified relevant MRS research articles and created an open-source database containing methods, results, and other article information as a resource. Using this database, expectation values and ranges for metabolite concentrations and T2 relaxation times are established based upon a meta-analyses of healthy and diseased brains.
Collapse
Affiliation(s)
- Aaron T Gudmundson
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Annie Koo
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA, USA
| | - Anna Virovka
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA, USA
| | - Alyssa L Amirault
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA, USA
| | - Madelene Soo
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA, USA
| | - Jocelyn H Cho
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA, USA
| | - Georg Oeltzschner
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Richard A E Edden
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Craig E L Stark
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA, USA.
| |
Collapse
|
5
|
Okada T, Kuribayashi H, Urushibata Y, Fujimoto K, Akasaka T, Seethamraju RT, Ahn S, Isa T. GABA, glutamate and excitatory-inhibitory ratios measured using short-TE STEAM MRS at 7-Tesla: Effects of macromolecule basis sets and baseline parameters. Heliyon 2023; 9:e18357. [PMID: 37539101 PMCID: PMC10393741 DOI: 10.1016/j.heliyon.2023.e18357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 07/10/2023] [Accepted: 07/14/2023] [Indexed: 08/05/2023] Open
Abstract
Rationale and objectives Macromolecules (MMs) affect the precision and accuracy of neurochemical quantification in magnetic resonance spectroscopy. A measured MM basis is increasingly used in LCModel analysis combined with a spline baseline, whose stiffness is controlled by a parameter named DKNTMN. The effects of measured MM basis and DKNTMN were investigated. Materials and methods Twenty-six healthy subjects were prospectively enrolled and scanned twice using a short echo-time Stimulated Echo Acquisition Mode (STEAM) at 7-T. Using LCModel, analyses were conducted using the simulated MM basis (MMsim) with DKNTMN 0.15 and an MM basis measured inhouse (MMmeas) with DKNTMN of 0.15, 0.30, 0.60 and 1.00. Cramér-Rao lower bound (CRLB) and the concentrations of gamma-aminobutyric acid (GABA), glutamate and excitatory-inhibitory ratio (EIR), in addition to MMs were statistically analyzed. Measurement stability was evaluated using coefficient of variation (CV). Results CRLBs of GABA were significantly lower when using MMsim than MMmeas; those of glutamate were 2-3. GABA concentrations were significantly higher in the analysis using MMsim than MMmeas where concentrations were significantly higher with DKNTMN of 0.15 or 0.30 than 0.60 or 1.00. Difference in glutamate concentration was not significant. EIRs showed the same difference as in GABA depending on the DKNTMN values. CVs between test-retest scans were relatively stable for glutamate but became larger as DKNTMN increased for GABA and EIR. Conclusion Neurochemical quantification depends on the parameters of the basis sets used for fitting. Analysis using MMmeas with DKNTMN of 0.30 conformed best to previous studies and is recommended.
Collapse
Affiliation(s)
| | | | | | - Koji Fujimoto
- Human Brain Research Center, Tokyo, Japan
- Department of Real World Data Research and Development, Graduate School of Medicine, Kyoto University, Japan
| | | | | | - Sinyeob Ahn
- Siemens Medical Solutions, Berkeley, California, USA
| | | |
Collapse
|
6
|
Gudmundson AT, Koo A, Virovka A, Amirault AL, Soo M, Cho JH, Oeltzschner G, Edden RA, Stark C. Meta-analysis and Open-source Database for In Vivo Brain Magnetic Resonance Spectroscopy in Health and Disease. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.02.10.528046. [PMID: 37205343 PMCID: PMC10187197 DOI: 10.1101/2023.02.10.528046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Proton ( 1 H) Magnetic Resonance Spectroscopy (MRS) is a non-invasive tool capable of quantifying brain metabolite concentrations in vivo . Prioritization of standardization and accessibility in the field has led to the development of universal pulse sequences, methodological consensus recommendations, and the development of open-source analysis software packages. One on-going challenge is methodological validation with ground-truth data. As ground-truths are rarely available for in vivo measurements, data simulations have become an important tool. The diverse literature of metabolite measurements has made it challenging to define ranges to be used within simulations. Especially for the development of deep learning and machine learning algorithms, simulations must be able to produce accurate spectra capturing all the nuances of in vivo data. Therefore, we sought to determine the physiological ranges and relaxation rates of brain metabolites which can be used both in data simulations and as reference estimates. Using the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines, we've identified relevant MRS research articles and created an open-source database containing methods, results, and other article information as a resource. Using this database, expectation values and ranges for metabolite concentrations and T 2 relaxation times are established based upon a meta-analyses of healthy and diseased brains.
Collapse
Affiliation(s)
- Aaron T. Gudmundson
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD
| | - Annie Koo
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA
| | - Anna Virovka
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA
| | - Alyssa L. Amirault
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA
| | - Madelene Soo
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA
| | - Jocelyn H. Cho
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA
| | - Georg Oeltzschner
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD
| | - Richard A.E. Edden
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD
| | - Craig Stark
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA
| |
Collapse
|
7
|
Genovese G, Deelchand DK, Terpstra M, Marjańska M. Quantification of GABA concentration measured noninvasively in the human posterior cingulate cortex with 7 T ultra-short-TE MR spectroscopy. Magn Reson Med 2023; 89:886-897. [PMID: 36372932 PMCID: PMC9792442 DOI: 10.1002/mrm.29514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 10/11/2022] [Accepted: 10/12/2022] [Indexed: 11/16/2022]
Abstract
PURPOSE The increased spectral dispersion achieved at ultra-high field permits quantification of γ-aminobutyric acid (GABA) concentrations at ultra-short-TE without editing. This work investigated the influence of spectral quality and different LCModel fitting approaches on quantification of GABA. Additionally, the sensitivity with which cross-sectional and longitudinal variations in GABA concentrations can be observed was characterized. METHODS In - vivo spectra were acquired in the posterior cingulate cortex of 10 volunteers at 7 T using a STEAM sequence. Synthetically altered spectra with different levels of GABA signals were used to investigate the reliability of GABA quantification with different LCModel fitting approaches and different realizations of SNR. The synthetically altered spectra were also used to characterize the sensitivity of GABA quantification. RESULTS The best LCModel fitting approach used stiff spline baseline, no soft constraints, and measured macromolecules in the basis set. With lower SNR, coefficients of variation increased dramatically. Longitudinal and cross-sectional variations in GABA of 10% could be detected with 79 and 48 participants per group, respectively. However, the small cohort may bias the calculation of the coefficients of variation and of the sample size that would be needed to detect variations in GABA. CONCLUSION Reliable quantification of normal and abnormal GABA concentrations was achieved for high quality 7 T spectra using LCModel fitting.
Collapse
Affiliation(s)
- Guglielmo Genovese
- Center for Magnetic Resonance Research, Department of
Radiology, University of Minnesota, 2021 6 St SE, Minneapolis, MN
55455, USA
| | - Dinesh K. Deelchand
- Center for Magnetic Resonance Research, Department of
Radiology, University of Minnesota, 2021 6 St SE, Minneapolis, MN
55455, USA
| | - Melissa Terpstra
- NextGen Imaging Facility, NextGen Precision Health
Institute, University of Missouri, 1011 Hospital Dr, Columbia, MO 65211, USA
| | - Małgorzata Marjańska
- Center for Magnetic Resonance Research, Department of
Radiology, University of Minnesota, 2021 6 St SE, Minneapolis, MN
55455, USA
| |
Collapse
|
8
|
Okada T, Fujimoto K, Fushimi Y, Akasaka T, Thuy DHD, Shima A, Sawamoto N, Oishi N, Zhang Z, Funaki T, Nakamoto Y, Murai T, Miyamoto S, Takahashi R, Isa T. Neuroimaging at 7 Tesla: a pictorial narrative review. Quant Imaging Med Surg 2022; 12:3406-3435. [PMID: 35655840 PMCID: PMC9131333 DOI: 10.21037/qims-21-969] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 02/05/2022] [Indexed: 01/26/2024]
Abstract
Neuroimaging using the 7-Tesla (7T) human magnetic resonance (MR) system is rapidly gaining popularity after being approved for clinical use in the European Union and the USA. This trend is the same for functional MR imaging (MRI). The primary advantages of 7T over lower magnetic fields are its higher signal-to-noise and contrast-to-noise ratios, which provide high-resolution acquisitions and better contrast, making it easier to detect lesions and structural changes in brain disorders. Another advantage is the capability to measure a greater number of neurochemicals by virtue of the increased spectral resolution. Many structural and functional studies using 7T have been conducted to visualize details in the white matter and layers of the cortex and hippocampus, the subnucleus or regions of the putamen, the globus pallidus, thalamus and substantia nigra, and in small structures, such as the subthalamic nucleus, habenula, perforating arteries, and the perivascular space, that are difficult to observe at lower magnetic field strengths. The target disorders for 7T neuroimaging range from tumoral diseases to vascular, neurodegenerative, and psychiatric disorders, including Alzheimer's disease, Parkinson's disease, multiple sclerosis, epilepsy, major depressive disorder, and schizophrenia. MR spectroscopy has also been used for research because of its increased chemical shift that separates overlapping peaks and resolves neurochemicals more effectively at 7T than a lower magnetic field. This paper presents a narrative review of these topics and an illustrative presentation of images obtained at 7T. We expect 7T neuroimaging to provide a new imaging biomarker of various brain disorders.
Collapse
Affiliation(s)
- Tomohisa Okada
- Human Brain Research Center, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Koji Fujimoto
- Department of Real World Data Research and Development, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Yasutaka Fushimi
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Thai Akasaka
- Human Brain Research Center, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Dinh H. D. Thuy
- Human Brain Research Center, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Atsushi Shima
- Human Brain Research Center, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Nobukatsu Sawamoto
- Department of Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Naoya Oishi
- Medial Innovation Center, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Zhilin Zhang
- Department of Psychiatry, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Takeshi Funaki
- Department of Neurosurgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Yuji Nakamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Toshiya Murai
- Department of Psychiatry, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Susumu Miyamoto
- Department of Neurosurgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Ryosuke Takahashi
- Department of Neurology, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Tadashi Isa
- Human Brain Research Center, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| |
Collapse
|
9
|
Reid MA, Forloines MR, Salibi N. Reproducibility of 7-T brain spectroscopy using an ultrashort echo time STimulated Echo Acquisition Mode sequence and automated voxel repositioning. NMR IN BIOMEDICINE 2022; 35:e4631. [PMID: 34622996 PMCID: PMC8862634 DOI: 10.1002/nbm.4631] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 09/15/2021] [Accepted: 09/16/2021] [Indexed: 06/13/2023]
Abstract
Establishing the reproducibility of brain MRS is important for clinical studies so that researchers can evaluate changes in metabolites due to treatment or the course of a disease and better understand the brain in healthy and disordered states. Prior 7-T MRS reproducibility studies using the stimulated echo acquisition mode (STEAM) sequence have focused on the anterior cingulate cortex or posterior cingulate cortex and precuneus. The purpose of this study was to evaluate the reproducibility of metabolite measurements in the dorsolateral prefrontal cortex (DLPFC) using an ultrashort echo time (TE) STEAM sequence and automated voxel repositioning. Spectra were acquired during two scan sessions from nine subjects using the AutoAlign method for voxel repositioning. Reproducibility was evaluated with coefficients of variation (CVs) and percentage differences. The mean intrasubject CVs were less than 6% for the major metabolites glutamate, N-acetylaspartate, total creatine, total choline, and myo-inositol. The mean CVs were less than 20% for the smaller signals of GABA, glutamine, glutathione, and taurine. These results indicate that 7-T MRS using a STEAM sequence with ultrashort TE and automated voxel repositioning provides excellent reproducibility of metabolites in the DLPFC.
Collapse
Affiliation(s)
- Meredith A. Reid
- MRI Research Center, Department of Electrical and Computer Engineering, Auburn University, Auburn, Alabama, USA
- Alabama Advanced Imaging Consortium, Auburn, Alabama, USA
| | - Martha R. Forloines
- Alzheimer’s Disease Center, Department of Neurology, University of California, Davis, Sacramento, California, USA
| | | |
Collapse
|
10
|
Sen K, Whitehead M, Castillo Pinto C, Caldovic L, Gropman A. Fifteen years of urea cycle disorders brain research: Looking back, looking forward. Anal Biochem 2022; 636:114343. [PMID: 34637785 PMCID: PMC8671367 DOI: 10.1016/j.ab.2021.114343] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 07/13/2021] [Accepted: 08/17/2021] [Indexed: 01/03/2023]
Abstract
Urea cycle disorders (UCD) are inherited diseases resulting from deficiency in one of six enzymes or two carriers that are required to remove ammonia from the body. UCD may be associated with neurological damage encompassing a spectrum from asymptomatic/mild to severe encephalopathy, which results in most cases from Hyperammonemia (HA) and elevation of other neurotoxic intermediates of metabolism. Electroencephalography (EEG), Magnetic resonance imaging (MRI) and Proton Magnetic resonance spectroscopy (MRS) are noninvasive measures of brain function and structure that can be used during HA to guide management and provide prognostic information, in addition to being research tools to understand the pathophysiology of UCD associated brain injury. The Urea Cycle Rare disorders Consortium (UCDC) has been invested in research to understand the immediate and downstream effects of hyperammonemia (HA) on brain using electroencephalogram (EEG) and multimodal brain MRI to establish early patterns of brain injury and to track recovery and prognosis. This review highlights the evolving knowledge about the impact of UCD and HA in particular on neurological injury and recovery and use of EEG and MRI to study and evaluate prognostic factors for risk and recovery. It recognizes the work of others and discusses the UCDC's prior work and future research priorities.
Collapse
Affiliation(s)
- Kuntal Sen
- Division of Neurogenetics and Neurodevelopmental Pediatrics, Children's National Hospital, Washington D.C., United States
| | - Matthew Whitehead
- Division of Radiology, Children's National Hospital, Washington D.C., United States
| | | | - Ljubica Caldovic
- Childrens' Research Institute, Children's National Hospital, Washington D.C., United States
| | - Andrea Gropman
- Division of Neurogenetics and Neurodevelopmental Pediatrics, Children's National Hospital, Washington D.C., United States.
| |
Collapse
|
11
|
Finkelman T, Furman-Haran E, Paz R, Tal A. Quantifying the excitatory-inhibitory balance: A comparison of SemiLASER and MEGA-SemiLASER for simultaneously measuring GABA and glutamate at 7T. Neuroimage 2021; 247:118810. [PMID: 34906716 DOI: 10.1016/j.neuroimage.2021.118810] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Revised: 12/08/2021] [Accepted: 12/10/2021] [Indexed: 10/19/2022] Open
Abstract
The importance of the excitatory-inhibitory (E/I) balance in a wide range of cognitive and behavioral processes has prompted a commensurate interest in methods for reliably quantifying it. Proton Magnetic Resonance Spectroscopy (1H-MRS) remains the only method capable of safely and non-invasively measuring the concentrations of the brain's major excitatory (glutamate) and inhibitory (γ-aminobutyric-acid, GABA) neurotransmitters in-vivo. MRS relies on spectral Mescher-Garwood (MEGA) editing techniques at 3T to distinguish GABA from its overlapping resonances. However, with the increased spectral resolution at ultrahigh field strengths of 7T and above, non-edited spectroscopic techniques become potential viable alternatives to MEGA based approaches, and also address some of their shortcomings, such as signal loss, sensitivity to transmitter inhomogeneities and temporal resolution. We present a comprehensive comparison of both edited and non-edited strategies at 7T for simultaneously quantifying glutamate and GABA from the dorsal anterior cingulate cortex (dACC), and evaluate their reproducibility and relative bias. The combined root-mean-square test-retest reproducibility of Glu and GABA (CVE/I) was as low as 13.3% for unedited MRS at TE=80 ms using SemiLASER localization, while edited MRS at TE=80 ms yielded CVE/I=20% and 21% for asymmetric and symmetric MEGA editing, respectively. An unedited SemiLASER acquisition using a shorter echo time of TE=42 ms yielded CVE/I as low as 24.9%. Our results show that non-edited sequences at an echo time of 80 ms provide better reproducibility than either edited sequences at the same TE, or non-edited sequences at a shorter TE of 42 ms. This is supported by numerical simulations and is driven in part by a pseudo-singlet appearance of the GABA multiplets at TE=80 ms, and the excellent spectral resolution at 7T. Our results uphold a transition to non-edited MRS for monitoring the E/I balance at ultrahigh fields, and stress the importance of using a properly-optimized echo time.
Collapse
Affiliation(s)
- Tal Finkelman
- Department of Neurobiology, Weizmann Institute of Science, Rehovot, Israel; Department of Chemical and Biological Physics, Weizmann Institute of Science, 234 Herzel St., Rehovot 7610001, Israel
| | - Edna Furman-Haran
- Life Sciences Core Facilities, Weizmann Institute of Science, Rehovot, Israel
| | - Rony Paz
- Department of Neurobiology, Weizmann Institute of Science, Rehovot, Israel
| | - Assaf Tal
- Department of Chemical and Biological Physics, Weizmann Institute of Science, 234 Herzel St., Rehovot 7610001, Israel.
| |
Collapse
|
12
|
Cognitive control affects motor learning through local variations in GABA within the primary motor cortex. Sci Rep 2021; 11:18566. [PMID: 34535725 PMCID: PMC8448760 DOI: 10.1038/s41598-021-97974-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 08/27/2021] [Indexed: 02/08/2023] Open
Abstract
The primary motor cortex (M1) is crucial for motor learning; however, its interaction with other brain areas during motor learning remains unclear. We hypothesized that the fronto-parietal execution network (FPN) provides learning-related information critical for the flexible cognitive control that is required for practice. We assessed network-level changes during sequential finger tapping learning under speed pressure by combining magnetic resonance spectroscopy and task and resting-state functional magnetic resonance imaging. There was a motor learning-related increase in preparatory activity in the fronto-parietal regions, including the right M1, overlapping the FPN and sensorimotor network (SMN). Learning-related increases in M1-seeded functional connectivity with the FPN, but not the SMN, were associated with decreased GABA/glutamate ratio in the M1, which were more prominent in the parietal than the frontal region. A decrease in the GABA/glutamate ratio in the right M1 was positively correlated with improvements in task performance (p = 0.042). Our findings indicate that motor learning driven by cognitive control is associated with local variations in the GABA/glutamate ratio in the M1 that reflects remote connectivity with the FPN, representing network-level motor sequence learning formations.
Collapse
|
13
|
Abstract
After introduction of the first human 7 tesla (7T) system in 1999, 7T MR systems have been employed as one of the most advanced platforms for human MR research for more than 20 years. Currently, two 7T MR models are approved for clinical use in the U.S.A. The approval facilitated introduction of the 7T system, summing up to around 100 worldwide. The approval in Japan is much awaited. As a clinical MR scanner, the 7T MR system is drawing attention in terms of safety.Several large-sized studies on bioeffects have been reported for vertigo, dizziness, motion disturbances, nausea, and others. Such effects might also be found in MR workers and researchers. Frequency and severity of reported bioeffects will be presented and discussed, including their variances. The high resonance frequency and shorter RF wavelength of 7T increase the concern about the safety. Homogeneous RF pulse excitation is difficult even for the brain, and a multi-channel parallel transmit (pTx) system is considered mandatory. However, pTx may create a hot spot, which makes the estimation of specific absorption rate (SAR) to be difficult. The stronger magnetic field of 7T causes a large force of displacement and heating on metallic implants or devices, and the scan of patients with them should not be conducted at 7T. However, there are some opinions that such patients might be scanned even at 7T, if certain criteria are met. This article provides a brief review on the effect of the static magnetic field on humans (MR subjects, workers, and researchers) and neurons, in addition to scan sound, SAR, and metal implants and devices. Understanding and avoiding adverse effects will contribute to the reduction in safety risks and the prevention of incidents.
Collapse
Affiliation(s)
- Tomohisa Okada
- Human Brain Research Center, Graduate School of Medicine, Kyoto University
| | - Thai Akasaka
- Human Brain Research Center, Graduate School of Medicine, Kyoto University
| | - Dinh Hd Thuy
- Human Brain Research Center, Graduate School of Medicine, Kyoto University
| | - Tadashi Isa
- Human Brain Research Center, Graduate School of Medicine, Kyoto University
| |
Collapse
|