Khan AZ, Maxwell MJ, Parrott RM, Bowler AR, Glass EA, Miller D, Vasconcellos D, Brownhill JR, Austin LS, Cuff DJ, Murthi AM, Smith MJ, Wiater JM, Jawa A. Effect of vitamin E-enhanced highly cross-linked polyethylene on wear rate and particle debris in anatomic total shoulder arthroplasty: a biomechanical comparison to ultrahigh-molecular-weight polyethylene. J Shoulder Elbow Surg 2024; 33:1465-1472. [PMID: 38182025 DOI: 10.1016/j.jse.2023.11.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 11/03/2023] [Accepted: 11/14/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND Particle-induced osteolysis resulting from polyethylene wear remains a source of implant failure in anatomic total shoulder designs. Modern polyethylene components are irradiated in an oxygen-free environment to induce cross-linking, but reducing the resulting free radicals with melting or heat annealing can compromise the component's mechanical properties. Vitamin E has been introduced as an adjuvant to thermal treatments. Anatomic shoulder arthroplasty models with a ceramic head component have demonstrated that vitamin E-enhanced polyethylene show improved wear compared with highly cross-linked polyethylene (HXLPE). This study aimed to assess the biomechanical wear properties and particle size characteristics of a novel vitamin E-enhanced highly cross-linked polyethylene (VEXPE) glenoid compared to a conventional ultrahigh-molecular-weight polyethylene (UHMWPE) glenoid against a cobalt chromium molybdenum (CoCrMo) head component. METHODS Biomechanical wear testing was performed to compare the VEXPE glenoid to UHMWPE glenoid with regard to pristine polyethylene wear and abrasive endurance against a polished CoCrMo alloy humeral head in an anatomic shoulder wear-simulation model. Cumulative mass loss (milligrams) was recorded, and wear rate calculated (milligrams per megacycle [Mc]). Under pristine wear conditions, particle analysis was performed, and functional biologic activity (FBA) was calculated to estimate particle debris osteolytic potential. In addition, 95% confidence intervals for all testing conditions were calculated. RESULTS The average pristine wear rate was statistically significantly lower for the VEXPE glenoid compared with the HXLPE glenoid (0.81 ± 0.64 mg/Mc vs. 7.00 ± 0.45 mg/Mc) (P < .05). Under abrasive wear conditions, the VEXPE glenoid had a statistically significant lower average wear rate compared with the UHMWPE glenoid comparator device (18.93 ± 5.80 mg/Mc vs. 40.47 ± 2.63 mg/Mc) (P < .05). The VEXPE glenoid demonstrated a statistically significant improvement in FBA compared with the HXLPE glenoid (0.21 ± 0.21 vs. 1.54 ± 0.49 (P < .05). CONCLUSIONS A new anatomic glenoid component with VEXPE demonstrated significantly improved pristine and abrasive wear properties with lower osteolytic particle debris potential compared with a conventional UHMWPE glenoid component. Vitamin E-enhanced polyethylene shows early promise in shoulder arthroplasty components. Long-term clinical and radiographic investigation needs to be performed to verify if these biomechanical wear properties translate to diminished long-term wear, osteolysis, and loosening.
Collapse
Affiliation(s)
- Adam Z Khan
- Northwest Permanente P.C., Portland, OR, USA
| | | | | | | | | | | | | | | | - Luke S Austin
- Department of Orthopaedic Surgery, The Rothman Institute, Philadelphia, PA, USA
| | - Derek J Cuff
- Suncoast Orthopaedic Surgery and Sports Medicine, Venice, FL, USA
| | | | - Matthew J Smith
- Department of Orthopedic Surgery, University of Missouri, Columbia, MO, USA
| | - J Michael Wiater
- Department of Orthopaedic Surgery, Beaumont Hospital, Royal Oak, MI, USA
| | - Andrew Jawa
- New England Baptist Hospital, Boston, MA, USA.
| |
Collapse
|
2
|
Rutledge JC, Dey Hazra RO, Geissbuhler AR, Yamaura K, Dey Hazra ME, Hanson JA, Rupp MC, Millett PJ. Does glenoid version and its correction affect outcomes in anatomic shoulder arthroplasty? A systematic review. J Shoulder Elbow Surg 2024; 33:e384-e399. [PMID: 38122888 DOI: 10.1016/j.jse.2023.10.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 10/20/2023] [Accepted: 10/30/2023] [Indexed: 12/23/2023]
Abstract
BACKGROUND Correction of glenoid retroversion is commonly performed in anatomic total shoulder arthroplasty (TSA) to increase component contact area and decrease eccentric loading of the glenoid component. Despite demonstrated biomechanical advantages, limited information exists on the clinical benefit of correcting glenoid retroversion. The purpose of this systematic review is to critically evaluate the existing literature on the effect of preoperative and postoperative glenoid retroversion on clinical functional and radiologic outcomes in patients who underwent anatomic TSA. METHODS A systematic literature review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses using PubMed, Embase, and Cochrane Library evaluating the impact of glenoid retroversion on clinical and radiologic outcomes of TSA. English-language studies of level I through IV evidence were included. Blinded reviewers conducted multiple screens and methodological quality was appraised using the Modified Coleman Methodology Score. RESULTS Sixteen studies, including 3 level III and 13 level IV studies (1211 shoulders), satisfied all inclusion criteria. To address glenoid retroversion, 9 studies used corrective reaming techniques, and 4 studies used posteriorly augmented glenoids. Two studies used noncorrective reaming techniques. Mean preoperative retroversion ranged from 12.7° to 24° across studies. Eleven studies analyzed the effect of glenoid retroversion on clinical outcomes, including patient-reported outcome scores (PROs), range of motion (ROM), or clinical failure or revision rates. Most studies (8 of 11) did not report any significant association of pre- or postoperative glenoid retroversion on any clinical outcome. Of the 3 studies that reported significant effects, 1 study reported a negative association between preoperative glenoid retroversion and PROs, 1 study reported inferior postoperative abduction in patients with postoperative glenoid retroversion greater than 15°, and 1 study found an increased clinical failure rate in patients with higher postoperative retroversion. Ten studies reported radiographic results (medial calcar resorption, Central Peg Lucency [CPL] grade, Lazarus lucency grade) at follow-up. Only 1 study reported a significant effect of pre- and postoperative retroversion greater than 15° on CPL grade. CONCLUSION There is currently insufficient evidence that pre- or postoperative glenoid version influences postoperative outcomes independent of other morphologic factors such as joint line medialization. Given that noncorrective reaming demonstrated favorable postoperative outcomes, and postoperative glenoid version was not significantly and consistently found to impact outcomes, there is inconclusive evidence that correcting glenoid retroversion is routinely required.
Collapse
Affiliation(s)
| | - Rony-Orijit Dey Hazra
- Steadman Philippon Research Institute, Vail, CO, USA; Department for Shoulder and Elbow Surgery, Charité - Centrum für Muskuloskeletale Chirurgie, Berlin, Germany
| | | | - Kohei Yamaura
- Steadman Philippon Research Institute, Vail, CO, USA
| | | | - Jared A Hanson
- Steadman Philippon Research Institute, Vail, CO, USA; Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Marco-Christopher Rupp
- Steadman Philippon Research Institute, Vail, CO, USA; Department for Orthopaedic Sports Medicine, Technical University of Munich, Munich, Germany
| | - Peter J Millett
- Steadman Philippon Research Institute, Vail, CO, USA; The Steadman Clinic, Vail, CO, USA.
| |
Collapse
|
3
|
Karimi A, Reddy RP, Njoku-Austin C, Nazzal E, James MG, Lin A. Reverse total shoulder arthroplasty for primary osteoarthritis with restricted preoperative forward elevation demonstrates similar outcomes but faster range of motion recovery compared to anatomic total shoulder arthroplasty. J Shoulder Elbow Surg 2024; 33:S104-S110. [PMID: 38485082 DOI: 10.1016/j.jse.2024.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 02/29/2024] [Accepted: 03/09/2024] [Indexed: 04/26/2024]
Abstract
BACKGROUND Reverse total shoulder arthroplasty (RSA) has been increasingly utilized for a variety of shoulder pathologies that are difficult to treat with anatomical total shoulder arthroplasty (TSA). Few studies have compared the outcomes of TSA vs. RSA in patients with cuff intact glenohumeral osteoarthritis and poor preoperative forward elevation. This study aimed to determine whether there is a difference in functional outcomes and postoperative range of motion (ROM) between TSA and RSA in these patients. METHODS This retrospective cohort study included 116 patients who underwent RSA or TSA between 2013 and 2022 for the treatment of rotator cuff intact primary osteoarthritis with restricted preoperative forward flexion (FF) and a minimum 1-year follow-up. Each arthroplasty group was divided into 2 subgroups: patients with preoperative FF between 91° and 120° or FF lower than or equal to 90°. Patients' clinical outcomes, including active ROM, American Shoulder and Elbow Surgeons score, visual analog scale for pain, and subjective shoulder value were collected. Clinical and radiographic complications were evaluated. RESULTS There was no significant difference between RSA and TSA in terms of sex (58.3% male vs. 62.2% male, P = .692), or follow-up duration (20.1 months vs. 17.7 months, P = .230). However, the RSA cohort was significantly older (72.0 ± 8.2 vs. 65.4 ± 10.6, P = .012) and weaker in FF and (ER) before surgery (P < .001). There was no difference between RSA (57 patients) and TSA (59 patients) in visual analog scale pain score (1.2 ± 2.3 vs. 1.3 ± 2.3, P = .925), subjective shoulder value score (90 ± 15 vs. 90 ± 15, P = .859), or American Shoulder and Elbow Surgeons score (78.4 ± 20.5 vs. 82.1 ± 23.2, P = .476). Postoperative active ROM was statistically similar between RSA and TSA cohorts in FF (145 ± 26 vs. 146 ± 23, P = .728) and ER (39 ± 15 vs. 41 ± 15, P = .584). However, internal rotation was lower in the RSA cohort (P < .001). This was also true in each subgroup. RSA led to faster postoperative FF and ER achievement at 3 months (P < .001). There was no statistically significant difference in complication rates between cohorts. CONCLUSION This study demonstrates that patients with glenohumeral osteoarthritis who have a structurally intact rotator cuff but limited preoperative forward elevation can achieve predictable clinical improvement in pain, ROM, and function after either TSA or RSA. Reverse arthroplasty may be a reliable treatment option in patients at risk for developing rotator cuff failure.
Collapse
Affiliation(s)
- Amin Karimi
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, Pittsburgh, PA, USA; Research Development Unit, Department of Orthopaedic Surgery, Taleghani Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Rajiv P Reddy
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, Pittsburgh, PA, USA
| | - Confidence Njoku-Austin
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, Pittsburgh, PA, USA
| | - Ehab Nazzal
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, Pittsburgh, PA, USA
| | - Michael G James
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, Pittsburgh, PA, USA
| | - Albert Lin
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, Pittsburgh, PA, USA.
| |
Collapse
|
4
|
Ardebol J, Flores A, Kiliç AĪ, Pak T, Menendez ME, Denard PJ. Patients 75 years or older with primary glenohumeral arthritis and an intact rotator cuff show similar clinical improvement after reverse or anatomic total shoulder arthroplasty. J Shoulder Elbow Surg 2024; 33:1254-1260. [PMID: 38072034 DOI: 10.1016/j.jse.2023.10.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 10/22/2023] [Accepted: 10/24/2023] [Indexed: 02/17/2024]
Abstract
BACKGROUND The optimal management of primary glenohumeral arthritis (GHOA) in the elderly is an ongoing topic of debate. The purpose of this study was to compare functional outcomes and complications in patients aged 75 years or older treated with anatomic total shoulder arthroplasty (TSA) or reverse shoulder arthroplasty (RSA) for primary GHOA with an intact rotator cuff. METHODS A retrospective study was performed on a prospectively maintained database which was queried for patients 75 years of age or older who underwent TSA or RSA for primary GHOA with an intact rotator cuff at a single institution between 2012 and 2021 with minimum 2-year follow-up. Patient-reported outcomes (PROs), including Visual Analog Scale for pain, American Shoulder and Elbow Surgeons, and Subjective Shoulder Value, as well as active range of motion including forward flexion, external rotation, internal rotation, were collected preoperatively and postoperatively. Complications, reoperations, and satisfaction were also recorded. The percentage of patients achieving clinically significant improvement was evaluated with the minimally clinical important difference, substantial clinical benefit, and patient acceptable symptomatic state for each PRO. RESULTS One-hundred and 4 patients were available for analysis, including 67 TSA patients and 37 RSAs with a mean follow-up of 39.4 months. Preoperative baseline characteristics, PROs, and range of motion were similar between groups. RSA was more commonly performed for eccentric glenoid wear (Walch B2/B3, 62% vs. 22%; P < .001). While clinical outcomes improved comparably in both groups, the TSA cohort showed significantly greater improvement in external rotation (36° vs. 26°; P = .013). Both cohorts had low revision (3% for TSA vs. 0% for RSA) and complication (7% for TSA vs. 5% for RSA; P = .677) rates. Satisfaction was similar in both groups (93% for TSA vs. 92% for RSA; P = .900). Clinically significant improvement was comparable between groups based on the American Shoulder and Elbow Surgeons score (minimally clinical important difference, 93% for TSA vs. 100% for RSA; substantial clinical benefit, 82% vs. 95%; patient acceptable symptomatic state, 67% vs. 78%; P > .05). CONCLUSION In this retrospective small sample size comparison study, TSA and RSA provide similar short-term clinical outcomes for patients 75 years and older with primary GHOA and an intact rotator cuff. Complication and revision rates are comparably low at short-term follow-up. Our data suggests that advanced age alone should not be used as a decision-making tool for TSA vs. RSA in the setting of primary GHOA with an intact rotator cuff.
Collapse
Affiliation(s)
- Javier Ardebol
- Oregon Shoulder Institute at Southern Oregon Orthopedics, Medford, OR, USA
| | - Adrian Flores
- Oregon Shoulder Institute at Southern Oregon Orthopedics, Medford, OR, USA
| | - Ali Īhsan Kiliç
- Oregon Shoulder Institute at Southern Oregon Orthopedics, Medford, OR, USA; Shoulder Surgery, Department of Orthopedics, Izmir Bakircay University, Izmir, Turkey
| | - Theresa Pak
- Oregon Shoulder Institute at Southern Oregon Orthopedics, Medford, OR, USA
| | - Mariano E Menendez
- Oregon Shoulder Institute at Southern Oregon Orthopedics, Medford, OR, USA
| | - Patrick J Denard
- Oregon Shoulder Institute at Southern Oregon Orthopedics, Medford, OR, USA.
| |
Collapse
|
5
|
Cirino CM, Kantrowitz DE, Boucher T, Patel A, Duey AH, Cagle PJ, Flatow EL. Anatomic total shoulder arthroplasty for B2 glenoids treated with asymmetric reaming has equivalent survivorship and patient outcomes compared with type A glenoids at a mean 9-year follow-up. J Shoulder Elbow Surg 2024:S1058-2746(24)00310-0. [PMID: 38688420 DOI: 10.1016/j.jse.2024.03.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 03/04/2024] [Accepted: 03/11/2024] [Indexed: 05/02/2024]
Abstract
BACKGROUND Walch B2 glenoids can present a challenge to shoulder arthroplasty surgeons. Short-term studies have demonstrated that corrective reaming to 10° of retroversion in anatomic total shoulder arthroplasty (aTSA) can result in good outcomes; however, there is little data reporting the long-term outcomes in this cohort. B2 glenoids treated with high-side reaming present a theoretical risk of early glenoid component failure as one may ream into the subchondral bone. This study aimed to demonstrate that (1) B2 glenoids treated with corrective reaming have durable results and (2) offer similar results to Walch A1/2 in long-term follow-up. METHODS Patients who underwent aTSA by a single surgeon (E.L.F.) were identified from a shoulder arthroplasty registry. Inclusion criteria included Walch A1, A2, or B2 glenoid; a diagnosis of primary shoulder osteoarthritis; and a minimum radiographic and clinical follow-up of 5 years. Forty-three patients with B2 glenoids were compared to a cohort of 42 patients with A1 or A2 glenoids. Preoperative computed tomography (CT) and radiographs were used to assess deformity, glenoid version, and posterior subluxation of the humeral head. Postoperatively, patients were assessed with radiographs and patient-reported outcome measures including American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES) score, Simple Shoulder Test (SST) score, and visual analog scale (VAS). RESULTS Eighty-five shoulders (82 patients, 42 B2 and 43 A1/A2 glenoids) with an average follow-up of 9.4 years were included. In the B2 cohort, the average retroversion was 21.1° and posterior subluxation was 69.4% compared with 10.6° (P < .001) and 57.5% (P < .001), respectively, in the A1 or A2 cohort. The cohort demographics were similar except for male sex (B2 69.8% vs. A1 or A2 37.2%, P = .008). There was no difference between the cohorts in their improvement in ASES (P = .807), SST (P = .586), and VAS (P = .930) scores. There was no difference in lateral humeral offset (P = .889) or acromial humeral interval (P = .468) between initial postoperative and final follow-up visits. Survivorship for B2 glenoids was 97.6%, 94.1%, and 73.3% at 5, 10, and 15 years, respectively, compared with 97.6%, 91.9%, and 83.5% in type A glenoids. The revision rate was similar between the 2 groups (P = .432). Lazarus score (P = .682) and rates of humeral radiolucency (P = .366) and humeral osteolysis (P = .194) were similar between the 2 cohorts at final follow-up. CONCLUSION Asymmetric reaming of patients with B2 glenoids is a reliable method of glenoid preparation with excellent mid- to long-term clinical results, patient-reported outcomes, and low revision rates similar to their A1 and A2 counterparts.
Collapse
Affiliation(s)
- Carl M Cirino
- Department of Orthopedic Surgery, Mount Sinai Hospital, New York, NY, USA
| | - David E Kantrowitz
- Department of Orthopedic Surgery, Mount Sinai Hospital, New York, NY, USA
| | - Thomas Boucher
- Department of Orthopedic Surgery, Mount Sinai Hospital, New York, NY, USA.
| | - Akshar Patel
- Department of Orthopedic Surgery, Mount Sinai Hospital, New York, NY, USA
| | - Akiro H Duey
- Department of Orthopedic Surgery, Mount Sinai Hospital, New York, NY, USA
| | - Paul J Cagle
- Department of Orthopedic Surgery, Mount Sinai Hospital, New York, NY, USA
| | - Evan L Flatow
- Department of Orthopedic Surgery, Mount Sinai Hospital, New York, NY, USA
| |
Collapse
|
6
|
Ranieri R, Anzillotti G, Rose GD, Borroni M, Garofalo R, Castagna A. Anatomical total shoulder arthroplasty revision to reverse shoulder arthroplasty using convertible glenoid: a systematic review of clinical and radiological outcomes. INTERNATIONAL ORTHOPAEDICS 2024:10.1007/s00264-024-06188-3. [PMID: 38656616 DOI: 10.1007/s00264-024-06188-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Accepted: 04/13/2024] [Indexed: 04/26/2024]
Abstract
PURPOSE The aim of the present systematic review is to collect all the available evidence regarding the clinical and radiological results of revision to reverse shoulder arthroplasty (RSA) of modular anatomic shoulder prostheses (TSA) using a convertible metal-backed glenoid (MBG). METHODS This study was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Studies investigating revision of TSA to RSA utilizing a convertible MBG and reporting clinical and radiological outcomes were identified. RESULTS A total of five studies on the use of convertible modular glenoid component in the setting of TSA revision to RSA were finally included in the present systematic review. A total of 60 procedures were reported. Mean operative times was 65 min. Intraoperative complications included 3 cases of glenoid loosening. Only one case of dislocation was reported as postoperative complication. At mean follow-up of 32.3 months post-revision, no glenoid loosening was reported, VAS score decreased from 7.7 to 1.5, Constant Score increased from 24.8 to 57.6. CONCLUSIONS Revision to RSA after failed TSA using a convertible modular glenoid component was associated with a low rate of intraoperative and postoperative complications, low surgical time and led to good results in term of pain relieve and functional outcomes. Given the complexity and risk associated with revision of anatomic shoulder prosthesis having a convertible glenoid may help to simplify the procedure and improve clinical results.
Collapse
Affiliation(s)
- Riccardo Ranieri
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4 Pieve Emanuele, 20072, Milan, Italy.
| | - Giuseppe Anzillotti
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4 Pieve Emanuele, 20072, Milan, Italy
| | - Giacomo Delle Rose
- Shoulder and Elbow Unit, IRCCS Humanitas Research Hospital, via Manzoni 56 Rozzano, 20089, Milan, Italy
| | - Mario Borroni
- Shoulder and Elbow Unit, IRCCS Humanitas Research Hospital, via Manzoni 56 Rozzano, 20089, Milan, Italy
| | - Raffaele Garofalo
- Shoulder and Sport Medicine Unit, Miulli Hospital, Strada Prov. 127 Acquaviva - Santeramo Km, 4, 100 Acquaviva Delle Fonti, 70021, Bari, Italy
- Shoulder and Elbow Unit, IRCCS Humanitas Research Hospital, via Manzoni 56 Rozzano, 20089, Milan, Italy
| | - Alessandro Castagna
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4 Pieve Emanuele, 20072, Milan, Italy
- Shoulder and Elbow Unit, IRCCS Humanitas Research Hospital, via Manzoni 56 Rozzano, 20089, Milan, Italy
| |
Collapse
|
7
|
Berk AN, Cregar WM, Rao AJ, Trofa DP, Schiffern SC, Hamid N, Saltzman BM. Anatomic total shoulder arthroplasty with inlay glenoid component: A systematic review. Shoulder Elbow 2024; 16:119-128. [PMID: 38655412 PMCID: PMC11034471 DOI: 10.1177/17585732231154850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 01/14/2023] [Indexed: 04/26/2024]
Abstract
Background A total shoulder arthroplasty (TSA) system utilizing an inlay glenoid component has been proposed as a means of reducing glenoid component loosening while still providing patients with desirable functional and clinical outcomes. The purpose of this study was to systematically review current outcomes literature on TSA using an inlay glenoid component. Methods A literature search was conducted using PubMed/MEDLINE, Cochrane Database of Systematic Reviews, and Web of Science databases. Studies comparing pre- and postoperative functional and clinical outcomes were included. Results Five studies with 148 shoulders (133 patients) were included. Patient-reported outcomes improved, including the American Shoulder and Elbow Surgeons score (mean change 34.1 to 80.6), Penn Shoulder Score (mean change 43.3 to 85.5), Single Assessment Numeric Evaluation score (mean change 34.1 to 80.6), and visual analog scale-pain (mean change 6.9 to 1.6). Range of motion improved for forward elevation (mean change 109.6 to 156.2) and external rotation (mean change 21.5 to 50.8). Glenoid component loosening occurred in one shoulder (0.68%). Two revision surgeries (1.35%) were performed. Discussion The use of an inlay glenoid component is associated with improvements in postoperative pain, function, and satisfaction while minimizing rates of glenoid component loosening and the need for revision surgery over short-term follow-up. Level of evidence systematic review, level IV.
Collapse
Affiliation(s)
- Alexander N. Berk
- OrthoCarolina—Sports Medicine Center, Charlotte, NC, USA
- OrthoCarolina Research Institute, Charlotte, NC, USA
- Atrium Health—Musculoskeletal Institute,Charlotte, NC, USA
| | - William M. Cregar
- OrthoCarolina—Sports Medicine Center, Charlotte, NC, USA
- OrthoCarolina Research Institute, Charlotte, NC, USA
| | - Allison J. Rao
- University of Minnesota Physicians, University of Minnesota—Department of Orthopedic Surgery, Minneapolis, MN, USA
| | - David P. Trofa
- New York Presbyterian, Columbia University Medical Center—Department of Orthopaedics, New York, NY, USA
| | - Shadley C. Schiffern
- OrthoCarolina—Sports Medicine Center, Charlotte, NC, USA
- OrthoCarolina Research Institute, Charlotte, NC, USA
| | - Nady Hamid
- OrthoCarolina—Sports Medicine Center, Charlotte, NC, USA
- OrthoCarolina Research Institute, Charlotte, NC, USA
| | - Bryan M. Saltzman
- OrthoCarolina—Sports Medicine Center, Charlotte, NC, USA
- OrthoCarolina Research Institute, Charlotte, NC, USA
- Atrium Health—Musculoskeletal Institute,Charlotte, NC, USA
| |
Collapse
|
8
|
Hill JR, Olson JJ, Aleem AW, Keener JD, Zmistowski BM. Three-dimensional analysis of biplanar glenoid deformities: what are they and can they be virtually reconstructed with anatomic total shoulder arthroplasty implants? J Shoulder Elbow Surg 2024:S1058-2746(24)00140-X. [PMID: 38423250 DOI: 10.1016/j.jse.2024.01.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 12/26/2023] [Accepted: 01/01/2024] [Indexed: 03/02/2024]
Abstract
BACKGROUND Descriptions of glenoid deformities in glenohumeral osteoarthritis (GHOA) have focused on the axial plane. Less is known regarding arthritic glenoids with higher amounts of superior inclination and little evidence exists to guide management of inclination or combined version-inclination deformity when performing anatomic total shoulder arthroplasty (aTSA). We hypothesized that biplanar deformities (BD) would be present in a higher proportion of GHOA patients than previously appreciated, and these deformities would be difficult to adequately reconstruct with contemporary aTSA implants. METHODS A retrospective query was performed of GHOA patients indicated for TSA 2012-2017 with a computed tomography (CT) scan within three months of surgery. Images were uploaded to three-dimensional (3D) software for automated measurements. Glenoids with superior inclination ≥10°, and retroversion ≥20° were considered to have BD. Walch classification was determined, and C-type glenoids were excluded. Rotator-cuff muscle cross-sectional area (CSA) was measured and fatty infiltration was graded. Glenoids with BD were virtually planned for aTSA with correction to neutral inclination and version, then with 5° superior inclination and 10° retroversion. RESULTS Two-hundred and sixty-eight shoulders in 250 patients were included; average age was 65 years, 67% male. There were no differences in inclination between Walch types (P = .25). Twenty-nine shoulders with BD were identified (11%). These deformities were not associated with age (P = .47) or gender (P = .50) but were skewed towards Walch B-type, specifically B2 (P = .03). Acromial index and posterior humeral head subluxation were higher in BD patients (P = .04, P < .001, respectively). Biplanar deformities had similar cuff CSA compared to those without but were less frequently associated with fatty infiltration of the subscapularis (P = .05). When correcting to neutral version and inclination, 41% BD could not be reconstructed. Of those that could, 94% required augmented implants. When correcting to 5° superior inclination and 10° retroversion, 10% could not be reconstructed. Of those that could, 58% required augmented implants. With partial correction, augment use was predicted by retroversion >26° (P = .009). Inclination did not predict augment use (P = .90). Final implant position commonly involved unseating in the posterosuperior quadrant and cancellous exposure in the anteroinferior quadrant. CONCLUSIONS This retrospective computed tomography (CT)-based study of 268 shoulders with GHOA found an 11% prevalence of BD. These deformities were commonly associated with Walch B2 wear patterns. Virtual aTSA planning showed a high failure rate (41%) when correcting to neutral version and inclination. Posteriorly augmented implants were frequently required, and often still involved unseating in the posterosuperior quadrant, increased cancellous exposure in the anteroinferior quadrant, and vault perforation.
Collapse
Affiliation(s)
- J Ryan Hill
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA; Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA.
| | - Jeffrey J Olson
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Alexander W Aleem
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Jay D Keener
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Benjamin M Zmistowski
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| |
Collapse
|
9
|
Vegas A, Cannon D, Lewis S, Glener J, Mekkawy KL, Rodriguez HC, Schodlbauer DF, Levy JC. Impact of humeral stem length on calcar resorption in anatomic total shoulder arthroplasty. J Shoulder Elbow Surg 2024; 33:130-138. [PMID: 37419442 DOI: 10.1016/j.jse.2023.05.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Revised: 05/08/2023] [Accepted: 05/28/2023] [Indexed: 07/09/2023]
Abstract
BACKGROUND Use of standard-length anatomic total shoulder (TSA) humeral stems has been associated with high rates of medial calcar bone loss. Calcar bone loss has been attributed to stress shielding, debris-induced osteolysis, and undiagnosed infection. Short stem and canal-sparing humeral components may provide more optimal stress distribution and thus lower rates of calcar bone loss related to stress shielding. The purpose of this study is to determine whether implant length will affect the rate and severity of medial calcar resorption. METHODS A retrospective review was performed on TSA patients treated with three different-length humeral implants (canal-sparing, short, and standard-length designs). Patients were matched 1:1:1 based on both gender and age (±4 years), resulting in 40 patients per cohort. Radiographic changes in medial calcar bone were evaluated and graded on a 4-point scale, from the initial postoperative radiographs to those at 3 months, 6 months, and 12 months. RESULTS The presence of any degree of medial calcar resorption demonstrated an overall rate of 73.3% at one year. At 3 months, calcar resorption was observed in 20% of the canal-sparing cohort, while the short and standard designs demonstrated resorption in 55% and 52.5%, respectively (P = .002). At 12 months, calcar resorption was seen in 65% of the canal-sparing design, while both the short and standard designs had a 77.5% rate of resorption (P = .345). The severity of calcar resorption for the canal-sparing cohort was significantly lower at all time points when compared to the short stem (3 months, P = .004; 6 months, P = .003; 12 months, P = .004) and at 3 months when compared to the standard-length stem (P = .009). CONCLUSION Patients treated with canal-sparing TSA humeral components have significantly lower rates of early calcar resorption with less severe bone loss when compared to patients treated using short and standard-length designs.
Collapse
Affiliation(s)
- Austin Vegas
- Department of Orthopedic Surgery, Larkin Community Hospital, South Miami, FL, USA
| | - Dylan Cannon
- Department of Orthopaedic Surgery, Oklahoma University, Oklahoma City, OK, USA
| | - Steven Lewis
- Holy Cross Orthopedic Institute, Fort Lauderdale, FL, USA
| | - Julie Glener
- Holy Cross Orthopedic Institute, Fort Lauderdale, FL, USA
| | | | - Hugo C Rodriguez
- Department of Orthopedic Surgery, Larkin Community Hospital, South Miami, FL, USA
| | - Daniel F Schodlbauer
- Levy Shoulder Center at Paley Orthopedic and Spine Institute, Boca Raton, FL, USA
| | - Jonathan C Levy
- Levy Shoulder Center at Paley Orthopedic and Spine Institute, Boca Raton, FL, USA.
| |
Collapse
|
10
|
Liebhauser M, Hohenberger G, Lohberger B, Hauer G, Deluca A, Sadoghi P. Implant breakage after shoulder arthroplasty: a systematic review of data from worldwide arthroplasty registries and clinical trials. BMC Musculoskelet Disord 2023; 24:804. [PMID: 37821859 PMCID: PMC10565962 DOI: 10.1186/s12891-023-06922-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 09/25/2023] [Indexed: 10/13/2023] Open
Abstract
BACKGROUND Implant breakage after shoulder arthroplasty is a rare complication after aseptic loosening, infection or persistent pain, resulting in malfunction of the components requiring revision surgery. This correlates with a high burden for the patient and increasing costs. Specific data of complication rates and implant breakage are available in detailed arthroplasty registries, but due to the rare occurrence and possibly underestimated value rarely described in published studies. The aim of this systematic review was to point out the frequency of implant breakage after shoulder arthroplasty. We hypothesized that worldwide arthroplasty registry datasets record higher rates of implant breakage than clinical trials. METHODS PubMed, MEDLINE, EMBASE, CINHAL, and the Cochrane Central Register of Controlled Trials database were utilized for this systematic review using the items "(implant fracture/complication/breakage) OR (glenoid/baseplate complication/breakage) AND (shoulder arthroplasty)" according to the PRISMA guidelines on July 3rd, 2023. Study selection, quality assessment, and data extraction were conducted according to the Cochrane standards. Case reports and experimental studies were excluded to reduce bias. The breakage rate per 100,000 observed component years was used to compare data from national arthroplasty registries and clinical trials, published in peer-reviewed journals. Relevant types of shoulder prosthetics were analyzed and differences in implant breakage were considered. RESULTS Data of 5 registries and 15 studies were included. Rates of implant breakage after shoulder arthroplasty were reported with 0.06-0.86% in registries versus 0.01-6.65% in clinical studies. The breakage rate per 100,000 observed component years was 10 in clinical studies and 9 in registries. There was a revision rate of 0.09% for registry data and 0.1% for clinical studies within a 10-year period. The most frequently affected component in connection with implant fracture was the glenoid insert. CONCLUSION Clinical studies revealed a similar incidence of implant failure compared to data of worldwide arthroplasty registries. These complications arise mainly due to breakage of screws and glenospheres and there seems to be a direct correlation to loosening. Periprosthetic joint infection might be associated with loosening of the prosthesis and subsequent material breakage. We believe that this analysis can help physicians to advise patients on potential risks after shoulder arthroplasty. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Martin Liebhauser
- Department of Traumatology, Klinikum Klagenfurt am Wörthersee, Klagenfurt, Austria
| | - Gloria Hohenberger
- Department of Traumatology, State Hospital Feldbach, Fürstenfeld, Austria
| | - Birgit Lohberger
- Department of Orthopedics and Trauma, Medical University of Graz, Graz, Austria
| | - Georg Hauer
- Department of Orthopedics and Trauma, Medical University of Graz, Graz, Austria
| | - Amelie Deluca
- Department of Orthopedic Surgery, SKA Warmbad Villach, Villach, Austria
| | - Patrick Sadoghi
- Department of Orthopedics and Trauma, Medical University of Graz, Graz, Austria.
| |
Collapse
|
11
|
Levins JG, Hoffman RA, Green A. Bilateral Posterior Bone Graft Augmentation for Severe Glenoid Hypoplasia Without Instability: A Case Report. JBJS Case Connect 2023; 13:01709767-202312000-00031. [PMID: 37976377 DOI: 10.2106/jbjs.cc.23.00274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
CASE A 40-year-old man with shoulder pain secondary to severe bilateral glenoid hypoplasia without posterior instability was treated successfully with bilateral posterior glenoid bone graft augmentation. CONCLUSION While glenoid hypoplasia is associated with a variety of patient presentations, treatment of the stable and nonarthritic shoulder is rarely described. A posterior glenoid bone graft can be used to augment deficient posterior glenoids, increasing the articulating surface area, restoring function, and potentially facilitating future shoulder arthroplasty.
Collapse
Affiliation(s)
- James G Levins
- Department of Orthopedic Surgery, University of Vermont Medical Center, Burlington, VT
| | - Ryan A Hoffman
- Department of Orthopedic Surgery, MedStar Union Memorial Hospital, Baltimore, MD
| | - Andrew Green
- Division of Shoulder and Elbow Surgery, Warren Alpert Medical School of Brown University, Providence, Rhode Island
| |
Collapse
|
12
|
Ardebol J, Pak T, Kiliç AĪ, Hwang S, Menendez ME, Denard PJ. Secondary Rotator Cuff Insufficiency After Anatomic Total Shoulder Arthroplasty. JBJS Rev 2023; 11:01874474-202309000-00005. [PMID: 37729463 DOI: 10.2106/jbjs.rvw.23.00099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
» Secondary rotator cuff insufficiency is a challenging complication after anatomic total shoulder arthroplasty.» Acute tears may be amenable to open or arthroscopic repair in some instances.» Chronic attritional tears are best managed with revision to reverse shoulder arthroplasty, especially in the elderly.» Increased glenoid inclination, larger critical shoulder angle, oversized humeral components, thicker glenoid components, and rotator cuff muscle fatty infiltration have all shown to contribute to tear risk.
Collapse
Affiliation(s)
| | | | - Ali Īhsan Kiliç
- Oregon Shoulder Institute, Medford, Oregon
- Izmir Bakircay University, Izmir, Turkey
| | | | | | | |
Collapse
|
13
|
Cooper KS, Powell GM, Baffour FI, Johnson MP, Frick MA. Incidence of complications related to shoulder arthroplasties identified on computed tomography. Emerg Radiol 2023:10.1007/s10140-023-02157-2. [PMID: 37415035 DOI: 10.1007/s10140-023-02157-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 06/29/2023] [Indexed: 07/08/2023]
Abstract
PURPOSE Determine incidence of shoulder arthroplasty complications identified on computed tomography (CT). MATERIALS AND METHODS Retrospective institutional database review of patients with shoulder arthroplasties who underwent CT between 01/2006-11/2021 at a tertiary academic referral center with subspecialized orthopedic shoulder surgeons. CT reports were reviewed for arthroplasty type and complication. Data were stratified and summarized. Associations between complications and arthroplasty types were determined with Chi-squared goodness of fit test. RESULTS Eight hundred twelve CTs in 797 unique patients were included (438 (53.9%) females and 374 (46.1%) males; mean age 67 ± 11 years). There were 403 total shoulder arthroplasties (TSA), 317 reverse total shoulder arthroplasties (rTSA), and 92 hemiarthroplasties (HA). Complications were present in 527/812 (64.9%) and incidences were: loosening/aseptic osteolysis 36.9%, periprosthetic failure 21.6%, periprosthetic fracture 12.3%, periprosthetic dislocation 6.8%, joint/pseudocapsule effusion 5.9%, prosthetic failure 4.8%, infection 3.8%, and periprosthetic collection 2.1%. Complications per arthroplasty were: 305/403 (75.7%) TSAs, 176/317 (55.5%) rTSAs, and 46/92 (50%) HAs (p < 0.001). Periprosthetic fracture (20.8%), prosthetic dislocation (9.8%), and prosthetic failure (7.9%) were highest in rTSAs (p < 0.001, p < 0.013, p < 0.001, respectively). Loosening/aseptic osteolysis most frequent in TSAs (54.1%) (p < 0.001). Periprosthetic failure most frequent in HA (32.6%) (p < 0.001). Significant associations were identified with joint/pseudocapsule effusion and loosening/aseptic osteolysis (p = 0.04) and prosthetic dislocation (p < .001). CONCLUSION In this single tertiary academic referral center cohort, the incidence of shoulder arthroplasty complication identified on CT was 64.9% and the most commonly occurring complication was loosening/aseptic osteolysis (36.9%). TSA had the highest incidence of complication (75.7%).
Collapse
Affiliation(s)
- Kendall S Cooper
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Garret M Powell
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
- Division of Hospital and Emergency Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
- Division of Musculoskeletal Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
| | - Francis I Baffour
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
- Division of Hospital and Emergency Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
- Division of Musculoskeletal Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Matthew P Johnson
- Department of Quantitative Health Sciences, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Matthew A Frick
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
- Division of Musculoskeletal Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| |
Collapse
|
14
|
Simister SK, Sato EH, Fleming K, Chalmers PN, Tashjian RZ. Comparing outcomes of central ingrowth peg vs. noningrowth pegged glenoid components during revision to reverse total shoulder arthroplasty. JSES Int 2023; 7:623-627. [PMID: 37426913 PMCID: PMC10328762 DOI: 10.1016/j.jseint.2023.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/11/2023] Open
Abstract
Background One innovation to reduce glenoid loosening in total shoulder arthroplasty (TSA) is a large, central ingrowth peg. However, when bone ingrowth fails to occur, there is often increased bone loss surrounding the central peg which may increase complexity of subsequent revisions. Our goal was to compare outcomes between central ingrowth pegs and noningrowth pegged glenoid components during revision to reverse total shoulder arthroplasty. Methods In a comparative retrospective case series, all patients who underwent TSA-to-reverse TSA revision between 2014 and 2022 were reviewed. Demographic varibles as well as clinical and radiographic outcomes were collected. Ingrowth central peg and noningrowth pegged glenoid groups were compared using t-test, Mann-Whitney U, Chi-Square, or Fisher's exact tests where indicated. Results Overall, 49 patients were included: 27 underwent revision from noningrowth and 22 from central ingrowth components. Females more commonly had noningrowth components (74% vs. 45%, P = .04) and preoperative external rotation was higher in central ingrowth components (P = .02). Time to revision was significantly earlier in central ingrowth components (2.4 vs. 7.5 years, P = .01). Structural glenoid allografting was required more with noningrowth components (30% vs. 5%, P = .03) and time to revision in patients ultimately requiring allograft reconstruction was significantly later (9.96 vs. 3.68 years, P = .03). Conclusion Central ingrowth pegs on glenoid components were associated with decreased need for structural allograft reconstruction during revision; however, time to revision was earlier in these components. Further research should focus on whether glenoid failure is due to glenoid component design, time to revision, or both.
Collapse
Affiliation(s)
- Samuel K. Simister
- Corresponding author: Samuel K. Simister, BS, Department of Orthopaedic Surgery, University of Utah, 847 S. Greenwood Terrace, Salt Lake City, UT 84105, USA.
| | | | | | | | | |
Collapse
|
15
|
Paul S, Arora M, Das L, Raja BS, Kalia RB. Average Indian Glenoid Sizes Are Smaller than All Commercially Available Glenoid Components: A Systematic Review. Indian J Orthop 2023; 57:1008-1022. [PMID: 37384007 PMCID: PMC10293529 DOI: 10.1007/s43465-023-00885-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 03/26/2023] [Indexed: 06/30/2023]
Abstract
Background Despite the variability in glenoid sizes geographically, most of the currently available commercial glenoid component designs are based on the glenoid parameters of the Caucasian population which may not be suitable for the Indian population due to a mismatch between the prosthesis and native anatomy. The aim of the present study is to systematically review the literature to determine the average glenoid anthropometric parameters in the Indian population. Methods A comprehensive literature search was conducted using preferred reporting items for systematic reviews and meta-analyses guidelines in the PubMed, EMBASE, Google Scholar, and Cochrane Library databases from the date of inception to May 2021. Any observational study conducted on the Indian population measuring the glenoid diameters, glenoid index, version, inclination, or any other glenoid measurements were included in the review. Results A total of 38 studies were included in this review. The glenoid parameters were assessed on intact cadaveric scapulae in 33 studies, on 3DCT in three studies, and 2DCT in one study. The pooled average of glenoid dimensions are as the following- the superoinferior diameter or height was 34.65 mm, anteroposterior1 diameter or maximum width was 23.72 mm, anteroposterior2 diameter or maximum width of the upper part of the glenoid was 17.05 mm, the glenoid index was 67.88, and the glenoid version was 1.75-degree retroversion. Males were having a mean height of 3.65 mm and maximum width of 2.74 mm larger than the females. A subgroup analysis revealed no significant difference between different parts of India in glenoid parameters. Conclusion The glenoid dimensions in the Indian population are smaller compared to the average European and American populations. The average glenoid maximum width of the Indian population is 1.3 mm smaller than the minimum glenoid baseplate size available in reverse shoulder arthroplasty. Glenoid components specific to the Indian market need to be designed to reduce glenoid failure attributable to the above findings. Level of evidence III.
Collapse
Affiliation(s)
- Souvik Paul
- Department of Orthopaedics, AMRI Hospitals Mukundapur, Kolkata, India
| | - Manit Arora
- Fortis Hospitals Mohali, Mohali, Punjab India
| | - Lakhsmana Das
- Department of Orthopedics, All India Institute of Medical Sciences Bhatinda, Punjab, India
| | - Balgovind S. Raja
- Department of Orthopedics, All India Institute of Medical Sciences Rishikesh, Rishikesh, India
| | - Roop Bhusan Kalia
- Department of Orthopedics, All India Institute of Medical Sciences Rishikesh, Rishikesh, India
| |
Collapse
|
16
|
Strelzow JA, Kusins JR, Ferreira LM, LeBel ME. "Can You Feel It": An Early Experience with Simulated Vibration to Recreate Glenoid Reaming. JB JS Open Access 2023; 8:e22.00134. [PMID: 37377860 PMCID: PMC10292736 DOI: 10.2106/jbjs.oa.22.00134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/29/2023] Open
Abstract
When developing educational simulators, meaningful haptic feedback is important. To our knowledge, no shoulder arthroplasty surgical simulator exists. This study focuses on simulating vibration haptics of glenoid reaming for shoulder arthroplasty using a novel glenoid reaming simulator. Methods We validated a novel custom simulator constructed using a vibration transducer transmitting simulated reaming vibrations to a powered nonwearing reamer tip through a 3D-printed glenoid. Validation and system fidelity were evaluated by 9 fellowship-trained shoulder surgeon experts performing a series of simulated reamings. We then completed the validation process through a questionnaire focused on experts' experience with the simulator. Results Experts correctly identified 52% ± 8% of surface profiles and 69% ± 21% of cartilage layers. Experts identified the vibration interface between simulated cartilage and subchondral bone (77% ± 23% of the time), indicating high fidelity for the system. An interclass correlation coefficient for experts' reaming to the subchondral plate was 0.682 (confidence interval 0.262-0.908). On a general questionnaire, the perceived utility of the simulator as a teaching tool was highly ranked (4/5), and experts scored "ease of instrument manipulation" (4.19/5) and "realism of the simulator" (4.11/5) the highest. The mean global evaluation score was 6.8/10 (range 5-10). Conclusions We examined a simulated glenoid reamer and feasibility of haptic vibrational feedback for training. Experts validated simulated vibration feedback for glenoid simulation reaming, and the results suggested that this may be a useful additional training adjuvant. Level of Evidence Level II, prospective study.
Collapse
Affiliation(s)
- Jason A. Strelzow
- The University of Chicago Medicine, Department of Orthopaedic Surgery and Rehabilitation Medicine, Chicago, Illinois
| | - Jonathan R. Kusins
- Roth|McFarlane Hand and Upper Limb Centre, Western University, London, Ontario, Canada
| | - Louis M. Ferreira
- Roth|McFarlane Hand and Upper Limb Centre, Western University, London, Ontario, Canada
- Department of Mechanical and Materials Engineering, Western University, London, Ontario, Canada
| | - Marie-Eve LeBel
- Roth|McFarlane Hand and Upper Limb Centre, Western University, London, Ontario, Canada
| |
Collapse
|
17
|
Mid- to long-term outcomes of a cemented, all-polyethylene pegged glenoid component in anatomic total shoulder arthroplasty. J Shoulder Elbow Surg 2023; 32:618-624. [PMID: 36179958 DOI: 10.1016/j.jse.2022.08.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 07/22/2022] [Accepted: 08/11/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND The primary aim of this study was to evaluate mid- to long-term survival of an all-polyethylene pegged glenoid component used in anatomic total shoulder arthroplasty (TSA). The secondary aim was to review clinical and radiologic outcomes. METHODS A retrospective analysis of a prospectively collected local arthroplasty register of consecutive patients undergoing TSA with an all-polyethylene pegged glenoid between January 2009 and December 2018 was undertaken. In total, 108 TSAs using this implant were performed in our unit in 98 patients (18 men and 80 women), with 10 patients undergoing bilateral TSA. The mean age at the time of the operation was 71.3 years (range, 44-87 years). The mean follow-up period was 5.1 years (range, 2-10.6 years). In addition to survival analysis, clinical evaluation included the postoperative Oxford Shoulder Score, Constant score, and visual analog scale (VAS) pain score, as well as range-of-motion assessment. Radiologic outcomes included an assessment of radiolucency based on the Lazarus grade. RESULTS Kaplan-Meier survival analysis revealed a 6-year survival estimate of 94.1% for all-cause revision. Revision was required in 6 patients: 4 for cuff failure and 2 for instability. At follow-up, the mean Oxford Shoulder Score was 38.2 (standard deviation [SD], 12.3); mean Constant score, 59.3 (SD, 17.0); and mean VAS pain score, 1.8 (SD, 2.5). Mean forward elevation at final follow-up was 111⁰ (SD, 26.6⁰); mean abduction, 102⁰ (SD, 34.0⁰). Clinical outcomes were maintained at long-term follow-up (>8 years), with the exception of the VAS pain score, which increased by 2.1 points (P = .034). Radiologic assessment revealed that 28 patients had radiolucency consistent with Lazarus grade ≥ 3 with clinical outcomes not being affected. CONCLUSIONS Mid- to long-term follow-up indicates a low revision rate and good clinical survivorship for cemented, all-polyethylene glenoid components. No patients, so far, have undergone revision for glenoid loosening, but radiographic follow-up has shown that 36% of these implants have signs of radiolucency. Further follow-up is required to determine longer-term survivorship.
Collapse
|
18
|
Edwards GA, Coghlan J, Hughes J, Wright W, Dallalana R, Bell ASN. Encouraging outcomes of stemless ceramic head anatomic shoulder arthroplasty in severe primary osteoarthritis (Walch type B glenoids). Shoulder Elbow 2023; 15:28-36. [PMID: 36895605 PMCID: PMC9990115 DOI: 10.1177/17585732211048120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 08/19/2021] [Accepted: 08/31/2021] [Indexed: 11/17/2022]
Abstract
Background: We report the radiological and functional outcomes at five years in patients with severe osteoarthritis of the glenohumeral joint and a Walch type B glenoid who have undergone stemless anatomic total shoulder replacement. Methods: A retrospective analysis of case notes, computed tomography scans and plain radiographs of patients undergoing anatomic total shoulder replacement for primary glenohumeral osteoarthritis were performed. Patients were grouped by the severity of their osteoarthritis using the modified Walch classification, glenoid retroversion and posterior humeral head subluxation. An evaluation was made using modern planning software. Functional outcomes were assessed using the American shoulder and elbow surgeons score, shoulder pain and disability index and visual analogue scale. Annual Lazarus scores were reviewed as regard to glenoid loosening. Results: Thirty patients were reviewed at 5 years. Analysis of all patient-reported outcome measures demonstrated significant improvement at 5-year review, American shoulder and elbow surgeons (p = <0.0001), shoulder pain and disability index (p = 0.0001), visual analogue scale (p = 0.0001). Radiological associations between Walch scores and Lazarus scores were not statistically significant (p = 0.1251) at 5 years. There were no associations between features of glenohumeral osteoarthritis and patient-reported outcome measures. Discussion: The severity of osteoarthritis did not show any association with glenoid component survivorship or with patient-reported outcome measures at 5 years review. Level of evidence: IV.
Collapse
Affiliation(s)
| | - Jennifer Coghlan
- Melbourne Shoulder and Elbow Centre, Melbourne, Australia
- Department of Surgery (School of Clinical Sciences at Monash
Health), Monash University, Melbourne, Australia
| | - Jeff Hughes
- North Shore Private
Hospital, Chatswood, Sydney, Australia
| | | | | | - A/Prof Simon Nicolas Bell
- Melbourne Shoulder and Elbow Centre, Melbourne, Australia
- Department of Surgery (School of Clinical Sciences at Monash
Health), Monash University, Melbourne, Australia
| |
Collapse
|
19
|
Aibinder WR, Uddin F, Bicknell RT, Krupp R, Scheibel M, Athwal GS. Stress shielding following stemless anatomic total shoulder arthroplasty. Shoulder Elbow 2023; 15:54-60. [PMID: 36895609 PMCID: PMC9990105 DOI: 10.1177/17585732211058804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 10/03/2021] [Accepted: 10/11/2021] [Indexed: 11/17/2022]
Abstract
Background Finite element analysis has suggested that stemless implants may theoretically decrease stress shielding. The purpose of this study was to assess the radiographic proximal humeral bone adaptations seen following stemless anatomic total shoulder arthroplasty. Methods A retrospective review of 152 prospectively followed stemless total shoulder arthroplasty utilizing a single implant design was performed. Anteroposterior and lateral radiographs were reviewed at standard time points. Stress shielding was graded as mild, moderate, and severe. The effect of stress shielding on clinical and functional outcomes was assessed. Also, the influence of subscapularis management on the occurrence of stress shielding was determined. Results At 2 years postoperatively, stress shielding was noted in 61 (41%) shoulders. A total of 11 (7%) shoulders demonstrated severe stress shielding with 6 occurring along the medial calcar. There was one instance of greater tuberosity resorption. At the final follow-up, no humeral implants were radiographically loose or migrated. There was no statistically significant difference in clinical and functional outcomes between shoulders with and without stress shielding. Patients undergoing a lesser tuberosity osteotomy had lower rates of stress shielding, which was statistically significant (p = 0.021). Discussion Stress shielding does occur at higher rates than anticipated following stemless total shoulder arthroplasty, but was not associated with implant migration or failure at 2 years follow-up. Level of evidence IV, Case series.
Collapse
Affiliation(s)
- William R Aibinder
- Department of Orthopaedic Surgery & Rehabilitation Medicine, SUNY Downstate Health Sciences University, Brooklyn, NY, USA
| | - Fares Uddin
- Bahrain Royal Guard, Bahrain Defense Force, Riffa, Bahrain
| | - Ryan T Bicknell
- Department of Surgery and Mechanical and Materials Engineering, Human Mobility Research Centre, Queen's University, Kingston, ON, Canada
| | - Ryan Krupp
- Norton Orthopaedic Specialists, Louisville, KY, USA
| | - Markus Scheibel
- Department of Shoulder and Elbow Surgery, Schulthess Clinic Zurich, Zurich, Switzerland.,Department of Shoulder and Elbow Surgery, Charité - Universitaetsmedizin Berlin, Berlin, Germany
| | - George S Athwal
- St Joseph's Health Care, Hand and Upper Limb Centre, University of Western Ontario, London, ON, Canada
| |
Collapse
|
20
|
Levins J, Molla V, Adkins J, Molino J, Pasarelli E, Paxton ES, Green A. Comparison of Humeral-Head Replacement with Glenoid-Reaming Arthroplasty (Ream and Run) Versus Anatomic Total Shoulder Arthroplasty: A Matched-Cohort Study. J Bone Joint Surg Am 2023; 105:509-517. [PMID: 36727972 DOI: 10.2106/jbjs.22.00650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND Glenoid component failure is a major concern after anatomic total shoulder arthroplasty (aTSA). Ream and run (RnR) is an alternative procedure that may avoid glenoid-related complications. The purpose of this study was to compare outcomes of RnR versus aTSA in younger patients with advanced glenohumeral osteoarthritis. METHODS This was a retrospective matched-cohort study of 110 patients who underwent aTSA and 57 patients who underwent RnR; patients were <66 years of age and had a minimum of 2 years of follow-up. Propensity matching was performed using 21 preoperative variables. Pre- and postoperative patient-reported outcome measures (PROMs) and health-related quality-of-life (HRQoL) scores, satisfaction with outcome, and revision data were analyzed. Mixed-effects models examined the association of preoperative variables with outcomes. RESULTS Thirty-nine patient pairs were matched. All patients were male, with a mean age of 58.6 ± 7.3 years and a mean follow-up 4.4 ± 2.3 years. The aTSA cohort had better final Simple Shoulder Test (SST) and American Shoulder and Elbow Surgeons (ASES) scores. However, in the mixed-effects model analysis, arthroplasty type was not associated with outcome. At 2 years postoperatively, a significantly greater percentage of aTSA patients achieved the substantial clinical benefit (SCB) for the ASES (100% versus 79.2%; p = 0.01) and the minimal clinically important difference (MCID) (89.7% versus 75%; p = 0.02) for the visual analog scale (VAS) for pain. At >5-year follow-up, there were no significant differences between the cohorts in the percentage who achieved the MCID, SCB, or patient acceptable symptom state (PASS) for the ASES, SST, and VAS for pain. Three patients underwent revision arthroplasty for pain after RnR, at a mean of 1.9 ± 1.7 years. Two patients underwent revision arthroplasty for glenoid loosening at 9.2 and 14 years after aTSA. CONCLUSIONS RnR and aTSA had comparable outcomes in most analyses. The greater early revision rate after RnR should focus attention on optimizing patient selection and postoperative management. Revision for glenoid loosening is a concern among younger and active patients. Longer-term study is needed to better understand the relative benefits and disadvantages of these procedures. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- James Levins
- Division of Shoulder and Elbow Surgery, Warren Alpert Medical School of Brown University, Providence, Rhode Island
| | | | | | | | | | | | | |
Collapse
|
21
|
Clinical and radiographic outcomes following anatomic total shoulder arthroplasty utilizing an inset glenoid component at 2-year minimum follow-up: a dual center study. J Shoulder Elbow Surg 2022; 32:1222-1230. [PMID: 36584872 DOI: 10.1016/j.jse.2022.11.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 11/18/2022] [Accepted: 11/20/2022] [Indexed: 12/29/2022]
Abstract
BACKGROUND Anatomic total shoulder arthroplasty (aTSA) is a successful and reproducible treatment for patients with painful glenohumeral arthritis. However, long-term outcomes using traditional onlay glenoid components have been tempered by glenoid loosening. Inset components have been proposed to minimize glenoid loosening by reducing edge-loading and opposite-edge lift-off forces with humeral translation. Successful short- and long-term outcomes have been reported while using inset glenoid implants. The current study is the largest study presenting a minimum of 2-year follow-up data following aTSA with an all-polyethylene inset glenoid component (Shoulder Innovations, Holland, MI, USA). METHODS A dual center, retrospective review of patients undergoing aTSA using an Inset glenoid component by 2 fellowship-trained shoulder surgeons at 2 separate institutions from August, 2016, to August, 2019, was performed. Minimum follow-up was 2 years. Range of motion (ROM), visual analog scale (VAS) pain scores, Single Assessment Numeric Evaluation (SANE), and American Shoulder and Elbow Surgeons (ASES) scores were obtained. Radiographic outcomes, including central peg lucency and glenoid loosening, were assessed by 3 independent reviewers on the postoperative Grashey and axillary radiographs obtained at the final follow-up. RESULTS Seventy-five shoulders were included for the final analysis. The mean age of the entire cohort was 64 (±11.4) years. Twenty-one (28%) glenoids were type A1, 10 (13.3%) were type A2, 13 (17.3%) were type B1, 22 (29.3%) were type B2, 6 (8%) were type B3, and 3 (4%) were type D. At a minimum follow-up of 24 months (mean: 28.7 months), a significant improvement in ROM in all planes was observed. Significant improvements in VAS (5.1-0.9, P < .001), SANE (39.5-91.2, P < .001), and ASES (43.7-86.6, P < .001) scores were observed. There were 4 (5.3%) cases of central peg lucency about the inset glenoid component and one (1.3%) case of glenoid loosening. No revisions were performed for glenoid loosening. CONCLUSION At a minimum of 2 years postoperatively, there were significant improvements in ROM, VAS, SANE, and ASES scores with very low rates of central peg lucency and glenoid loosening in patients undergoing aTSA with an inset glenoid component. Further work is needed to determine the long-term benefit of this novel implant.
Collapse
|
22
|
Ozdag Y, Baylor J, Hayes D, Grandizio LC. Arthroscopic Removal of the Polyethylene Glenoid Component After Total Shoulder Arthroplasty: A Systematic Review. J Shoulder Elb Arthroplast 2022; 6:24715492221142967. [PMCID: PMC9742720 DOI: 10.1177/24715492221142967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 09/09/2022] [Accepted: 11/13/2022] [Indexed: 12/13/2022] Open
Abstract
Purpose To identify prior studies of arthroscopic glenoid component removal after total shoulder arthroplasty (TSA) and understand indications, techniques and patient outcomes. Methods A search of the English language literature on arthroscopic removal of the glenoid component (ARGC) after TSA published between 2005 and 2021 was performed from MEDLINE and EMBASE databases. Articles with ARGC after TSA were identified and we recorded article characteristics as well as patient demographics and outcomes contained within the studies. Results A total of six publications (two case reports and four retrospective case series) detailing the outcome of ARGC performed on twenty-five shoulders were identified. The average time from index procedure to glenoid removal was 117 months and mean age at time of ARGC was 75 years. Although patient reported outcomes measures (PROMs) varied in type and reporting style, all articles reported improvements in PROMs. Twenty patients in this systematic review were evaluated for post-operative complications and the complication rate was found to be 15% (n = 3). There were 2 cases (18%) of superior migration of the humeral head relative to the glenoid and no reported cases of anterior or posterior humeral head subluxation. Two of 25 patients (8%) underwent subsequent open revision procedures. Conclusions The limited number of publications in this systematic review demonstrates that ARGC after TSA can result in improvements in both pain and PROMs. This less-invasive arthroscopic technique may be an alternative to open revision for lower demand patients; however, future prospective, comparative studies are necessary to better define indications.
Collapse
Affiliation(s)
- Yagiz Ozdag
- Department of Orthopaedic Surgery, Geisinger Commonwealth School of Medicine, Geisinger Musculoskeletal Institute, Danville, PA, USA
| | - Jessica Baylor
- Department of Orthopaedic Surgery, Geisinger Commonwealth School of Medicine, Geisinger Musculoskeletal Institute, Danville, PA, USA
| | - Daniel Hayes
- Department of Orthopaedic Surgery, Geisinger Commonwealth School of Medicine, Geisinger Musculoskeletal Institute, Danville, PA, USA
| | - Louis C Grandizio
- Department of Orthopaedic Surgery, Geisinger Commonwealth School of Medicine, Geisinger Musculoskeletal Institute, Danville, PA, USA,Louis C Grandizio, Geisinger Commonwealth School of Medicine, Geisinger Musculoskeletal Institute, Department of Orthopaedic Surgery, 16 Woodbine Lane, Danville, PA 17821, USA.
| |
Collapse
|
23
|
Knighton TW, Chalmers PN, Sulkar HJ, Aliaj K, Tashjian RZ, Henninger HB. Anatomic total shoulder glenoid component inclination affects glenohumeral kinetics during abduction: a cadaveric study. J Shoulder Elbow Surg 2022; 31:2023-2033. [PMID: 35550434 PMCID: PMC9481675 DOI: 10.1016/j.jse.2022.03.028] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 03/23/2022] [Accepted: 03/27/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Although typically favorable in outcome, anatomic total shoulder arthroplasty (aTSA) can require long-term revision. The most common cause for revision is glenoid loosening, which may result from eccentric cyclic forces and joint translations. "Rocking" of the glenoid component may be exacerbated by the joint geometry, such as glenoid inclination and version. Restoration of premorbid glenoid inclination may be preferable, although laboratory and computational models indicate that both superior inclination and inferior inclination have benefits. This discrepancy may arise because previous studies were limited by a lack of physiological conditions to test inclination. Therefore, a cadaveric shoulder simulator with 3-dimensional human motion was used to study joint contact and muscle forces with isolated changes in glenoid inclination. METHODS Eight human cadaveric shoulders were tested before and after aTSA. Scapular-plane abduction kinematics from human subjects were used to drive a cadaveric shoulder simulator with 3-dimensional scapulothoracic and glenohumeral motion. Glenoid inclination was varied from -10° to +20°, whereas compressive, superior-inferior shear, and anterior-posterior shear forces were collected with a 6-df load cell during motion. Outputs also included muscle forces of the deltoid and rotator cuff. Data were evaluated with statistical parametric mapping repeated-measures analysis of variance and t tests. RESULTS Inferior glenoid inclination (-10°) reduced both compressive and superior-inferior shear forces vs. neutral 0° inclination by up to 40%, and even more when compared with superior inclination (P < .001). Superior inclinations (+10° and +20°) tended to increase deltoid and rotator cuff forces vs. neutral 0° inclination or inferior inclination, on the order of 20%-40% (P ≤ .045). All force metrics except anterior-posterior shear were lowest for inferior inclination. Most aTSA muscle forces for neutral 0° inclination were not significantly different from native shoulders and decreased 45% and 15% in the posterior deltoid and supraspinatus, respectively (P ≤ .003). Joint translations were similar to prior reports in aTSA patients and did not differ between any inclinations or compared with native shoulders. Joint reaction forces were similar to those observed in human subjects with instrumented aTSA implants, providing confidence in the relative magnitude of our results. CONCLUSIONS Inferior inclination reduces overall forces in the shoulder. Superior inclinations increase the muscle effort required for the shoulder to achieve similar motion, thus increasing the forces exerted on the glenoid component. These results suggest that a preference toward aTSA glenoid components in inferior inclination may reduce the likelihood of glenoid loosening by reducing excessive muscle and joint contact forces.
Collapse
Affiliation(s)
- Tyler W Knighton
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Peter N Chalmers
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA
| | - Hema J Sulkar
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Klevis Aliaj
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Robert Z Tashjian
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA
| | - Heath B Henninger
- Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.
| |
Collapse
|
24
|
Preoperative Planning for Anatomic Total Shoulder Arthroplasty. J Am Acad Orthop Surg 2022; 30:e1207-e1216. [PMID: 36135930 DOI: 10.5435/jaaos-d-21-01119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Accepted: 05/08/2022] [Indexed: 02/01/2023] Open
Abstract
The success of total shoulder arthroplasty is dependent on both proper patient selection and restoration of the native anatomy. After proper patient selection, preoperative planning is essential to select implants that will allow the surgeon to properly restore soft-tissue tension and correct for deformity. Although it is possible to template implants with plain radiographs, these do not allow accurate measurements of the complex three-dimensional anatomy of the glenohumeral joint. CT can be used to further examine version of the glenoid and humerus, as well as humeral head subluxation. Three-dimensional reconstructions also allow for virtual implantation, resulting in a more reliable prediction of implant appearance. Commercial software is available that calculates parameters such as version; however, these have been shown to have variability when compared with measurements obtained by surgeons. Patient-specific instrumentation can also be obtained based on preoperative measurements; however, although it allowed for improved measurements when compared with two-dimensional imaging, there has been no difference in version error, inclination error, or positional offset of the glenoid implant when comparing patient-specific instrumentation with standard instrumentation. Intraoperative navigation can also be used to give real-time feedback on implant positioning; however, additional studies are needed to fully evaluate its benefit.
Collapse
|
25
|
Elmallah R, Swanson D, Le K, Kirsch J, Jawa A. Baseplate retroversion does not affect postoperative outcomes after reverse shoulder arthroplasty. J Shoulder Elbow Surg 2022; 31:2082-2088. [PMID: 35429631 DOI: 10.1016/j.jse.2022.02.043] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 02/14/2022] [Accepted: 02/24/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND There is concern that excessive glenoid component retroversion leads to altered biomechanics and baseplate failure in reverse shoulder arthroplasty (RSA). However, much of this has been rooted in the total shoulder arthroplasty experience. In the current literature, it is not well defined whether glenoid baseplate positioning in reverse arthroplasty affects functional outcomes. Our practice has been to preserve glenoid bone stock without aiming for a certain degree of retroversion. We aimed to evaluate the correlation between pre- and postoperative retroversion in a cohort of RSAs and determine the effect of glenoid retroversion on functional outcomes, range of motion, and postoperative complications. METHODS A retrospective review of patients who had an RSA between 2017 and 2019 was performed. Preoperative computed tomography scans were used to assess preoperative retroversion, and axillary radiographs were used for postoperative retroversion. Outcome measures included American Shoulder and Elbow Surgeons score, visual analog scale for pain score, Single Assessment Numeric Evaluation score, range of motion, radiographic lucency, and complications. RESULTS A total of 271 patients were eligible for the study. There was a 76.9% 2-year follow-up rate. In total 161 patients had postoperative retroversion ≤15° (group A), and 110 patients had retroversion >15° (group B). There were no significant differences in American Shoulder and Elbow Surgeons, visual analog scale, or Single Assessment Numeric Evaluation scores. There were also no significant differences in postoperative range of motion. There was 1 baseplate failure in each group, and there was 1 patient in group B with asymptomatic radiographic loosening (baseplate at risk). The mean change in pre- to postoperative retroversion was 1° and 4° in groups A and B, respectively. CONCLUSION There was no significant difference in postoperative functional outcomes, range of motion, or complications between patients who had baseplate retroversion ≤15° vs. those who had retroversion >15°.
Collapse
Affiliation(s)
- Randa Elmallah
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | | | - Kiet Le
- Boston Sports and Shoulder Center, Waltham, MA, USA; Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, MA, USA
| | - Jacob Kirsch
- Boston Sports and Shoulder Center, Waltham, MA, USA; Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, MA, USA
| | - Andrew Jawa
- Boston Sports and Shoulder Center, Waltham, MA, USA; Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, MA, USA.
| |
Collapse
|
26
|
Levins J, Passarelli E, Adkins J, Molino J, Henry H, Paxton ES, Green A. Early outcome of humeral head replacement with glenoid reaming arthroplasty (Ream and Run) for treatment of advanced glenohumeral osteoarthritis. J Shoulder Elbow Surg 2022; 31:1846-1858. [PMID: 35276348 DOI: 10.1016/j.jse.2022.01.152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 01/23/2022] [Accepted: 01/29/2022] [Indexed: 02/01/2023]
Abstract
INTRODUCTION Long-term outcomes of anatomic total shoulder arthroplasty (aTSA) can be compromised by glenoid loosening and failure. The purpose of this study was to evaluate the short- and midterm outcomes of humeral head replacement with glenoid reaming arthroplasty (Ream and Run) for the treatment of advanced glenohumeral osteoarthritis, and to identify associations between preoperative factors and outcomes. METHODS Forty-nine shoulders (mean age 60 ± 7 years) with minimum 2-year follow-up (mean 4.6 ± 1.7) were evaluated. Forty-three (87.8%) were male. Thirteen (26.5%) had previous nonarthroplasty shoulder surgery. There were 19 (38.8%) Walch type A and 30 (61.2%) type B glenoids. Pre- and postoperative shoulder motion, patient-reported outcomes (PROMs), and health-related quality of life (HRQoL) were assessed. Pre- and postoperative plain radiographs were evaluated. Mixed effects models were used to investigate factors associated with outcomes. RESULTS Active forward elevation and active external rotation improved from 111.7° ± 23.8° to 139.2° ± 21.1° and 13.3° ± 20.7° to 38.7° ± 14.7°, respectively (P < .001). The mean American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH), Simple Shoulder Test (SST), and visual analog scale (VAS) shoulder pain scores at the most recent follow-up were 86.6 ± 19.9, 10.1 ± 14.1, 10.5 ± 2.2, and 1.5 ± 2.3, respectively. The mean changes of PROMs were significant and exceeded the minimal clinically important difference for aTSA. The percentage maximal possible improvement for ASES, DASH, and SST were greater than 75%. Male sex (P < .008) and not having prior shoulder surgery (P < .04) were significantly associated with better absolute and greater change in PROMs. Age, preoperative shoulder motion, and Walch glenoid classification were not associated with PROMs. Five (10.2%, 95% confidence interval [CI] 1.8%-18.6%) patients underwent revision for pain. Three additional patients were dissatisfied at final follow-up without undergoing revision, resulting in 16.7% (95% CI 6.1%-27.2%) of patients being dissatisfied with their outcome after their initial RnR. Mean Short Form-6 Dimensions scores improved from 0.66 ± 0.12 to 0.77 ± 0.13 and mean EuroQol-5 Dimensions scores improved from 0.68 ± 0.20 to 0.85 ± 0.17 (P < .001). Improvement in HRQoL was significantly associated with nondominant arm treatment, increased age, and greater preoperative SST score. Annual medialization of the humeral head center of rotation was 0.56 ± 1.6 mm/yr. No radiographic measure was associated with long-term PROMs. CONCLUSION Ream and Run can provide significant and clinically important improvement in PROMs and HRQoL for a high percentage of patients at short- and midterm follow-up. This procedure is an appropriate alternative to aTSA in select patients.
Collapse
Affiliation(s)
- James Levins
- Division of Shoulder and Elbow Surgery, Department of Orthopaedic Surgery, Warren Alpert Medical School of Brown University, Providence, RI, USA
| | - Emily Passarelli
- Division of Shoulder and Elbow Surgery, Department of Orthopaedic Surgery, Warren Alpert Medical School of Brown University, Providence, RI, USA
| | - Jacob Adkins
- Division of Shoulder and Elbow Surgery, Department of Orthopaedic Surgery, Warren Alpert Medical School of Brown University, Providence, RI, USA
| | - Janine Molino
- Division of Shoulder and Elbow Surgery, Department of Orthopaedic Surgery, Warren Alpert Medical School of Brown University, Providence, RI, USA
| | | | - E Scott Paxton
- Division of Shoulder and Elbow Surgery, Department of Orthopaedic Surgery, Warren Alpert Medical School of Brown University, Providence, RI, USA
| | - Andrew Green
- Division of Shoulder and Elbow Surgery, Department of Orthopaedic Surgery, Warren Alpert Medical School of Brown University, Providence, RI, USA.
| |
Collapse
|
27
|
Melvani R, Diaz MA, Wilder L, Christmas KN, Simon P, Cronin KJ, Mighell MA, Frankle MA. Improved mechanical fixation of an all-polyethylene glenoid reduces postoperative radiolucent lines. J Shoulder Elbow Surg 2022; 31:e386-e398. [PMID: 35339705 DOI: 10.1016/j.jse.2022.02.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 02/02/2022] [Accepted: 02/08/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND The rationale for advances in implant design is to improve performance in comparison to their predecessors. The purpose of this study was to compare a newer, self-pressurizing peripheral peg glenoid to a traditional polyethylene pegged glenoid through biomechanical evaluation and a retrospective radiographic and clinical review. METHODS Three testing conditions (uncemented, partially cemented, and fully cemented) were chosen to assess the 2 component designs in a foam block model. The number of hammer hits to seat the component, amount of time to seat the component, and resistance-to-seat were collected. The implants were then cyclically loaded following ASTM F2028-17 testing standard. Clinically, postoperative radiographs of patients with a self-pressurized glenoid component (n = 225 patients) and traditional glenoid component (n = 206 patients) were evaluated for radiolucent lines and glenoid seating at various timepoints. Clinical outcomes (American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, Simple Shoulder Test, and visual analog scale pain scores) and complications were recorded. The presence of radiolucent lines at the bone-cement interface was evaluated using the Modified Franklin Grade and the Lazarus grade. RESULTS The self-pressurizing glenoid design required significantly more hammer hits than traditional glenoid designs in all groups tested (P < .029). Moreover, the self-pressurizing design had significantly more resistance-to-seat than traditional components in both the uncemented and partially cemented group (P < .002). No difference in resistance-to-seat was found between designs in the fully cemented group. The uncemented and partially cemented groups did not survive the full 50,000 cycles; however the self-pressurizing design had significantly less motion than the traditional design (P < .001). No differences between component designs were found in the fully cemented group at 50,000 cycles. The self-pressurizing glenoid component had 0.005% radiographic radiolucent lines, and the traditional glenoid component had 45% radiographic radiolucent lines, with 38% of the radiolucencies in the traditional glenoid component group being defined as grade E. There were no progressive radiolucencies, differences in clinical outcomes, or complications at 2 years postoperatively. CONCLUSION In the fully cemented condition, the 2 component designs had comparable performance; however, the differences in designs could be better observed in the uncemented group. The self-pressurizing all-polyethylene design studied has superior biomechanical stability. Clinically, the improved stability of the glenoid component correlated with a reduction of radiolucent lines and will likely lead to a reduction in glenoid component loosening.
Collapse
Affiliation(s)
| | - Miguel A Diaz
- Foundation for Orthopaedic Research and Education, Tampa, FL, USA
| | - Lauren Wilder
- Foundation for Orthopaedic Research and Education, Tampa, FL, USA
| | | | - Peter Simon
- Foundation for Orthopaedic Research and Education, Tampa, FL, USA; Department of Medical Engineering, University of South Florida, Tampa, FL, USA
| | - Kevin J Cronin
- Florida Orthopaedic Institute, Tampa, FL, USA; Department of Orthopaedics and Sports Medicine, University of South Florida Morsani College of Medicine, Tampa, FL, USA
| | - Mark A Mighell
- Florida Orthopaedic Institute, Tampa, FL, USA; Department of Orthopaedics and Sports Medicine, University of South Florida Morsani College of Medicine, Tampa, FL, USA
| | - Mark A Frankle
- Florida Orthopaedic Institute, Tampa, FL, USA; Department of Orthopaedics and Sports Medicine, University of South Florida Morsani College of Medicine, Tampa, FL, USA.
| |
Collapse
|
28
|
Preuss FR, Day HK, Peebles AM, Mologne MS, Provencher MT. Reverse Total Shoulder Arthroplasty for Treatment of Massive, Irreparable Rotator Cuff Tear. Arthrosc Tech 2022; 11:e1133-e1139. [PMID: 35782844 PMCID: PMC9244853 DOI: 10.1016/j.eats.2022.02.022] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 02/09/2022] [Indexed: 02/03/2023] Open
Abstract
Massive tears of the rotator cuff can result in severe functional deficits due to loss of the axial force couple and effective fulcrum that the intact cuff normally provides. For massive, irreparable rotator cuff tears, especially in the setting of early to moderate degenerative changes, reverse total shoulder arthroplasty functions to modify the center of joint rotation, allowing the deltoid and intact components of the cuff to carry out shoulder function more effectively. Our preferred technique uses a standard open deltopectoral shoulder approach with a 3-dimensional glenoid baseplate model and a 135° prosthesis in an onlay configuration to reduce the risk of scapular notching and increase lateralization of the humerus.
Collapse
Affiliation(s)
- Fletcher R. Preuss
- University of California Los Angeles Medical Center, Los Angeles, California, U.S.A
| | - Hannah K. Day
- Steadman Philippon Research Institute, Vail, Colorado, U.S.A
| | | | | | - Matthew T. Provencher
- Steadman Philippon Research Institute, Vail, Colorado, U.S.A,The Steadman Clinic, Vail, Colorado, U.S.A,Address correspondence to CAPT Matthew T. Provencher, M.D., M.B.A., M.C., U.S.N.R. (ret.), The Steadman Clinic, 181 W Meadow Dr, Ste 400, Vail, CO 81657, U.S.A.
| |
Collapse
|
29
|
Bitzer A, Rondinelli S, Hurwit DJ, Sonnenfeld JJ, Hong IS, Connor PM. Conversion of anatomic total shoulder arthroplasty to reverse shoulder arthroplasty using a unique hybrid glenoid component: technique and preliminary results. JSES REVIEWS, REPORTS, AND TECHNIQUES 2022; 2:155-163. [PMID: 37587957 PMCID: PMC10426665 DOI: 10.1016/j.xrrt.2021.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 08/18/2023]
Abstract
Background Degenerative arthritis of the shoulder is a common condition that is successfully treated with anatomic total shoulder arthroplasty (TSA). Rotator cuff disease has evolved as a leading cause of failure of anatomic TSA, requiring revision to reverse shoulder arthroplasty (RSA). This revision procedure can be extremely complex, particularly if removal of a well-fixed glenoid component is necessary. This case series outlines the technique and preliminary clinical results of conversion of anatomic TSA to RSA utilizing both modular humeral and hybrid glenoid components. Methods From July 2017 to December 2019, the senior author (PMC) performed 84 consecutive anatomic TSA procedures utilizing a modular humeral arthroplasty system and a unique hybrid glenoid component. Three cases (3/84, or 3.6%) required conversion from anatomic TSA to RSA because of postoperative traumatic rotator cuff failure. All modular revision cases were performed without humeral stem removal and with utilization of the existing, well-fixed hybrid glenoid central titanium peg as the foundation for glenoid component revision. Preoperative and postoperative American Shoulder and Elbow Surgeons scores, visual analog scale pain scores, forward flexion, and patient satisfaction were analyzed in this modular revision group. In addition, several perioperative variables including operative time, blood loss, and length of stay were compared between this modular revision group and a nonmodular anatomic TSA to RSA revision comparative cohort. Results At an average follow-up of 24 months, average active forward flexion, postoperative American Shoulder and Elbow Surgeons scores, and visual analog scale pain scores improved significantly compared with preoperative scores in the modular revision group. All three patients were satisfied with their outcome. The average total operative time (109 minutes vs. 154 minutes, P = .02), blood loss (183 cc vs. 500 cc, P = .08), and length of hospital stay (26.3 hours vs. 36.6 hours P < .05) were lower in the modular revision group than those in a nonmodular revision cohort. Conclusion Revision of anatomic TSA to RSA utilizing a modular humeral system and a convertible hybrid glenoid component that does not require removal of a well-fixed central titanium peg which serves as the foundation for glenoid component revision was performed efficiently, safely, and successfully in three cases. This technique results in significantly improved clinical outcomes when revision to RSA is needed while potentially decreasing perioperative complications in the revision setting.
Collapse
Affiliation(s)
| | | | | | | | - Ian S. Hong
- OrthoCarolina – Sports Medicine Center, Charlotte, NC, USA
- Atrium Health – Musculoskeletal Institute, Charlotte, NC, USA
| | - Patrick M. Connor
- OrthoCarolina – Sports Medicine Center, Charlotte, NC, USA
- Atrium Health – Musculoskeletal Institute, Charlotte, NC, USA
| |
Collapse
|
30
|
Weisse B, Lama S, Piskoty G, Affolter C, Aiyangar AK. Effect of two types of shoulder prosthesis on the muscle forces using a generic multibody model for different arm motions. Biomed Eng Online 2022; 21:17. [PMID: 35305644 PMCID: PMC8934495 DOI: 10.1186/s12938-022-00988-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 03/07/2022] [Indexed: 11/10/2022] Open
Abstract
Background This study aims to analyze the effects of a novel dual-bearing shoulder prosthesis and a conventional reverse shoulder prosthesis on the deltoid and rotator cuff muscle forces for four different arm motions. The dual-bearing prosthesis is a glenoid-sparing joint replacement with a moving center of rotation. It has been developed to treat rotator cuff arthropathy, providing an increased post-operative functionality. Methods A three-dimensional musculoskeletal OpenSim® model of an upper body, incorporating a natural gleno-humeral joint and a scapula-thoracic joint developed by Blana et al. (J Biomech 41: 1714-1721, 2008), was used as a reference for the natural shoulder. It was modified by integrating first a novel dual-bearing prosthesis, and second, a reverse shoulder prosthesis into the shoulder joint complex. Four different arm motions, namely abduction, scaption, internal and external rotation, were simulated using an inverse kinematics approach. For each of the three models, shoulder muscle forces and joint reaction forces were calculated with a 2 kg weight in the hand. Results In general, the maximal shoulder muscle force and joint reaction force values were in a similar range for both prosthesis models during all four motions. The maximal deltoid muscle forces in the model with the dual-bearing prosthesis were 18% lower for abduction and 3% higher for scaption compared to the natural shoulder. The maximal rotator cuff muscle forces in the model with the dual-bearing prosthesis were 36% lower for abduction and 1% higher for scaption compared to the natural shoulder. Although the maximal deltoid muscle forces in the model with the dual-bearing prosthesis in internal and external rotation were 52% and 64% higher, respectively, compared to the natural shoulder, the maximal rotator cuff muscle forces were 27% lower in both motions. Conclusion The study shows that the dual-bearing shoulder prosthesis is a feasible option for patients with rotator cuff tear and has a strong potential to be used as secondary as well as primary joint replacement. The study also demonstrates that computer simulations can help to guide the continued optimization of this particular design concept for successful clinical outcomes.
Collapse
|
31
|
The Evolution of Reverse Total Shoulder Arthroplasty-From the First Steps to Novel Implant Designs and Surgical Techniques. J Clin Med 2022; 11:jcm11061512. [PMID: 35329837 PMCID: PMC8949196 DOI: 10.3390/jcm11061512] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 03/06/2022] [Accepted: 03/08/2022] [Indexed: 02/04/2023] Open
Abstract
Purpose of Review: The purpose of this review is to summarize recent literature regarding the latest design modifications and biomechanical evolutions of reverse total shoulder arthroplasty and their impact on postoperative outcomes. Recent findings: Over the past decade, worldwide implantation rates of reverse total shoulder arthroplasty have drastically increased for various shoulder pathologies. While Paul Grammont’s design principles first published in 1985 for reverse total shoulder arthroplasty remained unchanged, several adjustments were made to address postoperative clinical and biomechanical challenges such as implant glenoid loosening, scapular notching, or limited range of motion in order to maximize functional outcomes and increase the longevity of reverse total shoulder arthroplasty. However, the adequate and stable fixation of prosthetic components can be challenging, especially in massive osteoarthritis with concomitant bone loss. To overcome such issues, surgical navigation and patient-specific instruments may be a viable tool to improve accurate prosthetic component positioning. Nevertheless, larger clinical series on the accuracy and possible complications of this novel technique are still missing.
Collapse
|
32
|
Dekker TJ, Grantham WJ, Lacheta L, Goldenberg BT, Hazra ROD, Rakowski DR, Dornan GJ, Horan MP, Millett PJ. Glenoid Retroversion Does Not Impact Clinical Outcomes or Implant Survivorship Following Total Shoulder Arthroplasty with Minimal, Non-Corrective Reaming. JSES Int 2022; 6:596-603. [PMID: 35813138 PMCID: PMC9264025 DOI: 10.1016/j.jseint.2022.02.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
Abstract
Hypothesis Methods Results Conclusion
Collapse
|
33
|
Ott N, Kieback JD, Welle K, Paul C, Burger C, Kabir K. The base of coracoid process as a reference for glenoid reconstruction in primary or revision reverse shoulder arthroplasty: CT-based anatomical study. Arch Orthop Trauma Surg 2022; 142:387-393. [PMID: 33113015 DOI: 10.1007/s00402-020-03642-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Accepted: 10/15/2020] [Indexed: 10/23/2022]
Abstract
INTRODUCTION Joint replacement surgery as a treatment for glenohumeral arthritis with glenoid bone loss is challenging. The aim of this study is to offer an anatomical orientation for glenoid reconstruction. METHODS In this study, we measured size, inclination and version of the glenoid surface, as well as the distance between the articular line of the glenoid, base of the coracoid process, and acromion using computer tomographic (CT) imaging of 131 study participants aged 19-88 years in the period of 2010-2013. RESULTS We measured a mean distance of 6.5 ± 0.2 mm from the glenoid articular line to the base of the coracoid process in the transverse CT plane. Body height has shown no significant impact on the glenoid morphology. We observed significant differences between males and females: The glenoid appeared to be located 5.2 ± 0.9 mm higher and the humeral head was 4.5 ± 0.7 mm larger in male subjects compared with females (r = .699; p < .01). CONCLUSION In our study, the base of the coracoid offers an anatomical reference during reconstruction of the glenoid in primary and revision shoulder arthroplasty. As only 2D-CT imaging allows for accurate assessment of glenoid bone defects, we consider conventional X-ray imaging insufficient for proper preoperative planning before shoulder arthroplasty. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Nadine Ott
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.
| | - Jan-Dirk Kieback
- Department of Orthopedic and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - Kristan Welle
- Department of Orthopedic and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - Christian Paul
- Johanniter Hospitals, Waldkrankenhaus Bonn, Bonn, Germany
| | - Christof Burger
- Department of Orthopedic and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| | - Koroush Kabir
- Department of Orthopedic and Trauma Surgery, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
34
|
Variability and reliability of 2-dimensional vs. 3-dimensional glenoid version measurements with 3-dimensional preoperative planning software. J Shoulder Elbow Surg 2022; 31:302-309. [PMID: 34411724 DOI: 10.1016/j.jse.2021.07.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 07/07/2021] [Accepted: 07/11/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Preoperative planning for total shoulder arthroplasty (TSA) may change according to the measured degree of glenoid version. Both 2-dimensional (2D) and 3-dimensional (3D) computed tomographic (CT) scans are used to measure glenoid version, with no consensus on which method is more accurate. However, it is generally accepted that 3D measurements are more reliable, yet most 3D reconstruction software currently in clinical use have never been directly compared to 2D. The purpose of this study is to directly compare 2D and 3D glenoid version measurements and determine the differences between the two. METHODS CT scans were performed preoperatively on 315 shoulders undergoing either anatomic or reverse TSA. 2D measurements of glenoid version were obtained manually using the Friedman method, whereas 3D measurements were obtained using the Equinoxe Planning Application (Exactech Inc.) 3D-reconstruction software. Negative version values indicate retroversion, whereas positive values indicate anteversion. Two observers collected the 2D measurements 2 separate times, and intra- and interobserver measurements were calculated. Groups were compared for variability using intraclass correlation coefficients (ICCs), and for differences in sample means using Student t tests. Additionally, samples were stratified by version value in order to better understand the potential sources of error between measurement techniques. RESULTS For the 2D measurements, intraobserver variability indicated excellent reproducibility for both observer 1 (ICC = 0.928, 95% confidence interval [CI] 0.911-0.942) and observer 2 (ICC = 0.964, 95% CI 0.955-0.971). Interobserver variability measurements also indicated excellent reproducibility (ICC = 0.915, 95% CI 0.778-0.956). The overall 2D version measurement average (-4.9° ± 10.3°) was significantly less retroverted than the 3D measurement average (-8.4° ± 9.1°) (P < .001), with 3D measurements yielding a more retroverted value 73% of the time. When stratified on the basis of version value with outliers excluded, there was no significant difference in the distribution of high-error samples within the data. DISCUSSION There was excellent reproducibility between the 2 observers in terms of both intra- and interobserver variability. The 3D measurement techniques were significantly more likely to return a more retroverted measurement, and high-error samples were evenly distributed throughout the data, indicating that there were no discernable trends in the degree of error observed. Shoulder surgeons should be aware that different glenoid version measurement strategies can yield different version measurements, as these can affect preoperative planning and surgeon decision making.
Collapse
|
35
|
Heifner JJ, Kumar AD, Wagner ER. Glenohumeral osteoarthritis with intact rotator cuff treated with reverse shoulder arthroplasty: a systematic review. J Shoulder Elbow Surg 2021; 30:2895-2903. [PMID: 34293419 DOI: 10.1016/j.jse.2021.06.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Revised: 06/08/2021] [Accepted: 06/12/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Although reverse shoulder arthroplasty (RSA) has shown satisfactory outcomes in rotator cuff-deficient shoulders, its performance in shoulders with an intact rotator cuff has not been fully elucidated. Shoulder osteoarthritis can present with alterations in glenoid morphology, which have contributed to inconsistent outcomes in anatomic shoulder replacement. The glenoid component is responsible for a predominance of these arthroplasty complications. Given these glenoid-related difficulties, RSA may provide a more favorable option. We aimed to summarize the current literature on rotator cuff intact osteoarthritis treated with primary RSA and to determine whether morphologic changes in the glenoid led to inferior outcomes. METHODS A literature search was performed using an inclusion criterion of primary RSA for osteoarthritis with an intact rotator cuff. The Modified Coleman Methodology Score was calculated to analyze reporting quality. Following appropriate exclusions, of the 1002 studies identified by the databases, 13 were selected. RESULTS Postoperative improvement in weighted means for Constant scores reached statistical significance (P = .02). The mean rate of major complications was 3.8%. A subset of 8 studies was created that detailed the following descriptions of altered glenoid morphology: "static posterior instability," "severe posterior subluxation," "posterior glenoid wear >20°," "significant posterior glenoid bone loss," "biconcave glenoid," "B2 glenoid," and "B/C glenoid." Within this subset, the mean complication rate was 4.7%, with 4 of the 7 studies having a rate ≤ 3%, and improvements in the Constant score (P = .002) and external rotation (P = .02) reached statistical significance. DISCUSSION RSA as treatment for osteoarthritis with an intact rotator cuff provides optimal outcomes with low complication rates across a short term of follow up. Preoperative considerations for using reverse arthroplasty in the treatment of osteoarthritis with an intact rotator cuff include glenoid retroversion, posterior humeral subluxation, and glenoid bone loss. The attributes of reverse arthroplasty that contribute to favorable outcomes in arthritic shoulders include its semiconstrained design and robust glenoid fixation. Soft-tissue imbalances as a consequence of pathologic glenoid morphology and chronic humeral subluxation can be mitigated with the RSA semiconstrained design. Glenoid bone loss can be effectively managed with RSA's robust glenoid fixation, with and without the use of bone graft. The capability to lateralize the joint center of rotation may be valuable when faced with a medialized glenoid wear pattern. The current findings suggest that reverse arthroplasty can achieve highly favorable outcomes for glenohumeral osteoarthritis with an intact rotator cuff.
Collapse
Affiliation(s)
| | - Anjali D Kumar
- Gillings School of Global Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - Eric R Wagner
- Division of Upper Extremity Surgery, Department of Orthopaedic Surgery, Upper Extremity Surgery Research, Emory University, Atlanta, GA, USA
| |
Collapse
|
36
|
Anatomic Total Shoulder Arthroplasty versus Hemiarthroplasty for Glenohumeral Osteoarthritis: A Systematic Review and Meta-Analysis. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app112110112] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Purpose: Both anatomic total shoulder arthroplasty (TSA) and shoulder hemiarthroplasty (SHA) are used for the management of end-stage glenohumeral osteoarthritis (GHOA). The present study compared TSA and SHA in terms of clinical outcome and complication rate. Methods: This meta-analysis followed the PRISMA guidelines. In October 2021, the following databases were accessed: Web of Science, Google Scholar, Pubmed, Scopus. All clinical trials comparing anatomical TSA versus SHA for GHOA were considered. Results: Data from 11,027 procedures were retrieved. The mean length of the follow-up was 81.8 (16 to 223.20) months. The mean age of the patients was 61.4 ± 8.6 years, and 56.0% (5731 of 10,228 patients) were women. At last follow-up, the age-adjusted constant score was greater following TSA (p < 0.0001), as were active elevation (p < 0.0001), flexion (p < 0.0001), abduction (p < 0.0001), and American Shoulder and Elbow Surgeons Shoulder Score (p < 0.0001). Postoperative pain (p < 0.0001) and revision rate (p = 0.02) were lower in the TSA group. Conclusions: Anatomic TSA performed better than SHA in patients with GHOA.
Collapse
|
37
|
Croucher J, Mahomed A. Concept and simulation of an alternative design for an orthopaedic shoulder implant. J Med Eng Technol 2021; 46:1-15. [PMID: 34549681 DOI: 10.1080/03091902.2021.1967489] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
For a first-time glenohumeral arthritis patient, total shoulder arthroplasty (TSA) is an option where the shoulder joint is replaced with an artificial humeral head that articulates against a cup attached to the glenoid. A patient with rotator cuff deficiency can undergo reverse total shoulder arthroplasty (RTSA) where the components are switched. Presented here is a concept design at simulation stage which offers a platform-based implant where either a system can be assembled and implanted for TSA or a reverse system for RTSA. Platform components and the glenoid baseplate have been designed as part of this concept stage. Modular components are also described as part of the concept, which can influence a patient's range of motion (ROM), as well as the effect of implant positioning within the patient. A 42 mm hemisphere is used as the articulating component providing a good balance between ROM, joint load and deltoid force. The most suitable material concluded for the concept design TSA was as follows: grade 5 Ti-6Al-4V for the humeral stem and baseplate and CoCrMo with cross-linked polyethylene (XLPE) for the metal-on-polymer bearing surface. Finite element analysis concluded that the concept prosthesis is able to withstand an impact force of six times bodyweight from a forward fall. A dynamic fatigue test concluded that the expected lifetime of the concept polymer bearing surface is 33 years.
Collapse
Affiliation(s)
- James Croucher
- Department of Mechanical Engineering, University of Birmingham, Birmingham, UK
| | - Aziza Mahomed
- Department of Mechanical Engineering, University of Birmingham, Birmingham, UK
| |
Collapse
|
38
|
Ricchetti ET, Jun BJ, Jin Y, Ho JC, Patterson TE, Dalton JE, Derwin KA, Iannotti JP. Relationship Between Glenoid Component Shift and Osteolysis After Anatomic Total Shoulder Arthroplasty: Three-Dimensional Computed Tomography Analysis. J Bone Joint Surg Am 2021; 103:1417-1430. [PMID: 33835109 PMCID: PMC8360268 DOI: 10.2106/jbjs.20.00833] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The purpose of this study was to evaluate glenoid component position and radiolucency following anatomic total shoulder arthroplasty (TSA) using sequential 3-dimensional computed tomography (3D CT) analysis. METHODS In a series of 152 patients (42 Walch A1, 16 A2, 7 B1, 49 B2, 29 B3, 3 C1, 3 C2, and 3 D glenoids) undergoing anatomic TSA with a polyethylene glenoid component, sequential 3D CT analysis was performed preoperatively (CT1), early postoperatively (CT2), and at a minimum 2-year follow-up (CT3). Glenoid component shift was defined as a change in component version or inclination of ≥3° from CT2 to CT3. Glenoid component central anchor peg osteolysis (CPO) was assessed at CT3. Factors associated with glenoid component shift and CPO were evaluated. RESULTS Glenoid component shift occurred from CT2 to CT3 in 78 (51%) of the 152 patients. CPO was seen at CT3 in 19 (13%) of the 152 patients, including 15 (19%) of the 78 with component shift. Walch B2 glenoids with a standard component and glenoids with higher preoperative retroversion were associated with a higher rate of shift, but not of CPO. B3 glenoids with an augmented component and glenoids with greater preoperative joint-line medialization were associated with CPO, but not with shift. More glenoid component joint-line medialization from CT2 to CT3 was associated with higher rates of shift and CPO. A greater absolute change in glenoid component inclination from CT2 to CT3 and a combined absolute glenoid component version and inclination change from CT2 to CT3 were associated with CPO. Neither glenoid component shift nor CPO was associated with worse clinical outcomes. CONCLUSIONS Postoperative 3D CT analysis demonstrated that glenoid component shift commonly occurs following anatomic TSA, with increased inclination the most common direction. Most (81%) of the patients with glenoid component shift did not develop CPO. Longer follow-up is needed to determine the relationships of glenoid component shift and CPO with loosening over time. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Eric T. Ricchetti
- Department of Orthopaedic Surgery, Orthopedic and
Rheumatologic Institute (E.T.R., J.C.H., T.E.P., and J.P.I.), Department of
Biomedical Engineering, Lerner Research Institute (B.-J.J. and K.A.D.), and
Department of Quantitative Health Sciences (Y.J. and J.E.D.), Cleveland Clinic,
Cleveland, Ohio
| | - Bong-Jae Jun
- Department of Orthopaedic Surgery, Orthopedic and
Rheumatologic Institute (E.T.R., J.C.H., T.E.P., and J.P.I.), Department of
Biomedical Engineering, Lerner Research Institute (B.-J.J. and K.A.D.), and
Department of Quantitative Health Sciences (Y.J. and J.E.D.), Cleveland Clinic,
Cleveland, Ohio
| | - Yuxuan Jin
- Department of Orthopaedic Surgery, Orthopedic and
Rheumatologic Institute (E.T.R., J.C.H., T.E.P., and J.P.I.), Department of
Biomedical Engineering, Lerner Research Institute (B.-J.J. and K.A.D.), and
Department of Quantitative Health Sciences (Y.J. and J.E.D.), Cleveland Clinic,
Cleveland, Ohio
| | - Jason C. Ho
- Department of Orthopaedic Surgery, Orthopedic and
Rheumatologic Institute (E.T.R., J.C.H., T.E.P., and J.P.I.), Department of
Biomedical Engineering, Lerner Research Institute (B.-J.J. and K.A.D.), and
Department of Quantitative Health Sciences (Y.J. and J.E.D.), Cleveland Clinic,
Cleveland, Ohio
| | - Thomas E. Patterson
- Department of Orthopaedic Surgery, Orthopedic and
Rheumatologic Institute (E.T.R., J.C.H., T.E.P., and J.P.I.), Department of
Biomedical Engineering, Lerner Research Institute (B.-J.J. and K.A.D.), and
Department of Quantitative Health Sciences (Y.J. and J.E.D.), Cleveland Clinic,
Cleveland, Ohio
| | - Jarrod E. Dalton
- Department of Orthopaedic Surgery, Orthopedic and
Rheumatologic Institute (E.T.R., J.C.H., T.E.P., and J.P.I.), Department of
Biomedical Engineering, Lerner Research Institute (B.-J.J. and K.A.D.), and
Department of Quantitative Health Sciences (Y.J. and J.E.D.), Cleveland Clinic,
Cleveland, Ohio
| | - Kathleen A. Derwin
- Department of Orthopaedic Surgery, Orthopedic and
Rheumatologic Institute (E.T.R., J.C.H., T.E.P., and J.P.I.), Department of
Biomedical Engineering, Lerner Research Institute (B.-J.J. and K.A.D.), and
Department of Quantitative Health Sciences (Y.J. and J.E.D.), Cleveland Clinic,
Cleveland, Ohio
| | - Joseph P. Iannotti
- Department of Orthopaedic Surgery, Orthopedic and
Rheumatologic Institute (E.T.R., J.C.H., T.E.P., and J.P.I.), Department of
Biomedical Engineering, Lerner Research Institute (B.-J.J. and K.A.D.), and
Department of Quantitative Health Sciences (Y.J. and J.E.D.), Cleveland Clinic,
Cleveland, Ohio
| |
Collapse
|
39
|
Tsitlakidis S, Doll J, Westhauser F, Wolf M, Hetto P, Maier M, Sowa B. Promising results after hemi-shoulder arthroplasty using pyrolytic carbon heads in young and middle-aged patients. Orthop Traumatol Surg Res 2021; 107:102896. [PMID: 33753266 DOI: 10.1016/j.otsr.2021.102896] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 10/03/2020] [Accepted: 10/30/2020] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The objective of this prospective cohort study was the assessment of short-term outcome results of shoulder hemiarthroplasty (HA) using pyrolytic carbon (PC) heads. PC has been introduced as a new material to avoid surgical revision due to glenoid erosion after HA. Glenoid erosion due to the use of metallic heads is known to reduce durability. HYPOTHESIS HA using PC heads shows comparable or better radiographic and clinical outcome compared to the conventional HA using metallic heads in the short-term. PATIENTS AND METHODS This study was conducted as a single center prospective cohort follow-up study including a total number of 16 consecutive HA with PC heads. Inclusion criteria were indication for HA, an intact rotator cuff, no proximal humeral fractures in patient's history and age>18years. Mean age at the time of arthroplasty was 52.8±10.8years. The mean follow-up was 24.3±8.1months. Baseline and follow-up Numeric Rating Scale (NRS), Constant Scores (CS), Range of Motion (ROM) and radiographs were assessed. RESULTS At a mean follow-up of 24.3months the mean CS (p<0.001), mean NRS (p<0.001) and mean ROM (p<0.05) improved statistically significant. Subgroup analysis revealed no differences between subgroups (sex, age, diagnosis, and handedness). Survival rate was high (94.1%). One periprosthetic fracture occurred as the only complication during follow-up. Radiographs showed glenoid erosion in one case and subacromial space reduction in two cases. DISCUSSION PC heads in HA show satisfying short-term results at a mean follow-up of two years, which are comparable to those of conventional HA. The clinical improvements were highly significant with good implant survival. However, long-term follow-up results are necessary, especially compared to conventional HA. LEVEL OF EVIDENCE IV; observational therapeutic cohort study.
Collapse
Affiliation(s)
- Stefanos Tsitlakidis
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany
| | - Julian Doll
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany
| | - Fabian Westhauser
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany
| | - Matthias Wolf
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany
| | - Pit Hetto
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany
| | - Michael Maier
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany; Schwaebisches Gelenkzentrum Stuttgart, Hohenheimer Str. 91, 70184 Stuttgart, Germany
| | - Boris Sowa
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany.
| |
Collapse
|
40
|
Pace GI, Thomas RA, Zale CL, Lewis GS, Kim RY, Kim HM. Effect of glenoid perforation during total shoulder arthroplasty on glenoid component cement fixation and suprascapular nerve. Shoulder Elbow 2021; 13:276-282. [PMID: 34659467 PMCID: PMC8512993 DOI: 10.1177/1758573219897040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2019] [Revised: 10/04/2019] [Accepted: 12/03/2019] [Indexed: 11/17/2022]
Abstract
BACKGROUND Arthritic glenoids are susceptible to vault perforation during total shoulder arthroplasty. We investigated the effects of glenoid perforation and subsequent cement extrusion on the suprascapular nerve and on the glenoid cement infiltration. METHODS Total shoulder arthroplasty using three-pegged glenoid components were performed on 10 cadaveric shoulders assigned to two groups (perforation vs. control). In perforation group, the glenoids were reamed eccentrically and intentionally perforated medially through the central peg hole, whereas control group received perpendicular reaming with no perforation. Bone cement was applied to each peg. Spatial relationship between the extruded cement and the suprascapular nerve, and the amount of cement infiltration into the cancellous bone were evaluated. RESULTS In perforation group, five specimens were perforated anteriorly, and two posteriorly. In the two posteriorly perforated specimens, the suprascapular nerve was in direct contact with extruded cement at the spinoglenoid notch. Perforation group showed significantly less cement infiltration into the cancellous bone than control group (p = 0.008). CONCLUSIONS Glenoid perforation decreases the volume of cement infiltration into the cancellous bone potentially compromising glenoid component fixation. Glenoid perforation tends to occur anteriorly rather than posteriorly in arthritic glenoids; however, if perforation occurs posteriorly, the suprascapular nerve is at immediate risk from the extruded cement.Level of evidence: Basic science study.
Collapse
Affiliation(s)
| | | | | | | | | | - H Mike Kim
- H Mike Kim, Department of Orthopaedics and
Rehabilitation, Penn State College of Medicine, Milton S. Hershey Medical Center, Mail
Code EC089, Hershey, PA 17033, USA.
| |
Collapse
|
41
|
Bartels DW, Marigi E, Sperling JW, Sanchez-Sotelo J. Revision Reverse Shoulder Arthroplasty for Anatomical Glenoid Component Loosening Was Not Universally Successful: A Detailed Analysis of 127 Consecutive Shoulders. J Bone Joint Surg Am 2021; 103:879-886. [PMID: 33764935 DOI: 10.2106/jbjs.20.00555] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Glenoid component loosening is a primary cause of failure of anatomical total shoulder arthroplasty (TSA) and is commonly associated with glenoid bone loss. The purpose of the present study was to evaluate the outcome and survival following revision to a reverse total shoulder arthroplasty (RSA) for the treatment of loosening of a polyethylene cemented glenoid component in the setting of failed TSA. METHODS Between 2010 and 2017, 151 shoulders underwent revision to RSA for the treatment of loosening of an anatomical polyethylene glenoid component. Shoulders with staged reconstruction for the treatment of infection were excluded. One hundred and twenty-seven patients (67 women and 60 men) had a single-stage reconstruction and were available for follow-up. The mean age at the time of surgery was 70 years (range, 41 to 93 years). In all cases, the humeral component was revised and a standard glenoid baseplate was utilized. Bone graft was used at the discretion of the treating surgeon. Medical records and radiographs were reviewed to collect demographic, intraoperative, and postoperative data; to quantify glenoid bone loss; and to determine the radiographic outcome. The mean duration of follow-up was 35 months (range, 24 to 84 months). RESULTS Revision to RSA resulted in significant improvements in terms of pain and motion. Sixteen shoulders (13%) underwent revision surgery for the treatment of baseplate loosening. Radiographic baseplate loosening was present in 6 additional shoulders (overall rate of baseplate loosening, 17%). Intraoperative fracture or fragmentation of the greater tuberosity occurred in 30 shoulders (24%). Other reoperations included resection for deep infection (3 shoulders), arthroscopic biopsies for unexplained persistent pain (2 shoulders), humeral tray exchange for dislocation (2 shoulders), revision for humeral loosening (1 shoulder), irrigation and debridement for hematoma (1 shoulder), and internal fixation of periprosthetic fracture (1 shoulder) (overall reoperation rate, 20%). Among shoulders with surviving implants at the time of the most recent follow-up, pain was rated as none or mild in 83 shoulders (65.4%) and the average active elevation and external rotation were 132° and 38°, respectively. With the numbers available, no risk factors for failure could be identified. CONCLUSIONS Revision RSA for the treatment of loosening of an anatomical polyethylene component was associated with a 17% glenoid mechanical failure rate. Although this procedure resulted in improvements in terms of pain and function, it was not universally successful and thus needs further refinement in order to improve outcomes. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
42
|
Prosthetic Bearing Surfaces in Anatomic and Reverse Total Shoulder Arthroplasty. J Am Acad Orthop Surg 2021; 29:414-422. [PMID: 33443383 DOI: 10.5435/jaaos-d-20-00166] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 12/06/2020] [Indexed: 02/01/2023] Open
Abstract
Total shoulder arthroplasty (TSA) and reverse TSA have provided an effective treatment for glenohumeral osteoarthritis; however, longevity of the procedure may be limited by osteolysis and polyethylene wear. In TSA, glenoid component failure occurs through several mechanisms, the most common being aseptic loosening and polyethylene wear. Newer bearing surfaces such as highly cross-linked ultra-high-molecular-weight polyethylene, vitamin E processing, ceramic heads, and pyrolytic carbon surfaces have shown improved wear characteristics in biomechanical and some early clinical studies. The purpose of this review is to provide a historical perspective and current state of the art of bearing surface technology in anatomic and reverse TSA.
Collapse
|
43
|
Schiffman CJ, Prabhakar P, Hsu JE, Shaffer ML, Miljacic L, Matsen FA. Assessing the Value to the Patient of New Technologies in Anatomic Total Shoulder Arthroplasty. J Bone Joint Surg Am 2021; 103:761-770. [PMID: 33587515 DOI: 10.2106/jbjs.20.01853] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Publications regarding anatomic total shoulder arthroplasty (TSA) have consistently reported that they provide significant improvement for patients with glenohumeral arthritis. New TSA technologies that have been introduced with the goal of further improving these outcomes include preoperative computed tomography (CT) scans, 3-dimensional preoperative planning, patient-specific instrumentation, stemless and short-stemmed humeral components, as well as metal-backed, hybrid, and augmented glenoid components. The benefit of these new technologies in terms of patient-reported outcomes is unknown. METHODS We reviewed 114 articles presenting preoperative and postoperative values for commonly used patient-reported metrics. The results were analyzed to determine whether patient outcomes have improved over the 20 years during which new technologies became available. RESULTS The analysis did not identify evidence that the results of TSA were statistically or clinically improved over the 2 decades of study or that any of the individual technologies were associated with significant improvement in patient outcomes. CONCLUSIONS Additional research is required to document the clinical value of these new technologies to patients with glenohumeral arthritis. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Corey J Schiffman
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, Washington
| | - Pooja Prabhakar
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, Washington
| | - Jason E Hsu
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, Washington
| | | | - Ljubomir Miljacic
- The Mountain-Whisper-Light Statistical Consulting, Seattle, Washington
| | - Frederick A Matsen
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, Washington
| |
Collapse
|
44
|
Hasler A, Bachmann E, Ker A, Viehöfer AF, Wieser K, Gerber C. Joint-line medialization after anatomical total shoulder replacement requires more rotator cuff activity to preserve joint stability. JSES Int 2021; 5:406-412. [PMID: 34136847 PMCID: PMC8178589 DOI: 10.1016/j.jseint.2020.11.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND The biomechanical effects of joint-line medialization during shoulder surgery are poorly understood. It was therefore the purpose of this study to investigate whether medialization of the joint line especially associated with total shoulder arthroplasty leads to changes in the rotator cuff muscle forces required to stabilize the arm in space. METHODS A validated computational 3-D rigid body simulation model was used to calculate generated muscle forces, instability ratios, muscle-tendon lengths and moment arms during scapular plane elevation. Measurements took place with the anatomical and a 2 mm and 6 mm lateralized or medialized joint line. RESULTS When the joint line was medialized, increased deltoid muscle activity was recorded throughout glenohumeral joint elevation. The rotator cuff muscle forces increased with medialization of the joint line in the early phases of elevation. Lateralization of the joint line led to higher rotator cuff muscle forces after 52° of glenohumeral elevation and to higher absolute values in muscle activity. A maximum instability ratio of >0.6 was recorded with 6 mm of joint-line medialization. CONCLUSION In this biomechanical study, medialization and lateralization of the normal joint line during total shoulder arthroplasty led to substantial load changes on the shoulder muscles used for stabilizing the arm in space. Specifically, medialization does not only lead to muscular shortening but also to increased load on the supraspinatus tendon during early arm elevation, the position which is already most loaded in the native joint.
Collapse
Affiliation(s)
- Anita Hasler
- Department of Orthopedics, University of Zürich, Balgrist University Hospital, Zürich, Switzerland
| | - Elias Bachmann
- Laboratory for Orthopedic Biomechanics, Orthopedic University Hospital Balgrist, Zürich, Switzerland
| | - Andrew Ker
- Department of Orthopedics, University of Zürich, Balgrist University Hospital, Zürich, Switzerland
| | - Arnd F. Viehöfer
- Department of Orthopedics, University of Zürich, Balgrist University Hospital, Zürich, Switzerland
| | - Karl Wieser
- Department of Orthopedics, University of Zürich, Balgrist University Hospital, Zürich, Switzerland
| | - Christian Gerber
- Department of Orthopedics, University of Zürich, Balgrist University Hospital, Zürich, Switzerland
| |
Collapse
|
45
|
Kozak T, Bauer S, Walch G, Al-Karawi S, Blakeney W. An update on reverse total shoulder arthroplasty: current indications, new designs, same old problems. EFORT Open Rev 2021; 6:189-201. [PMID: 33841918 PMCID: PMC8025709 DOI: 10.1302/2058-5241.6.200085] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Reverse total shoulder arthroplasty (RTSA) was originally developed because of unsatisfactory results with anatomic shoulder arthroplasty options for the majority of degenerative shoulder conditions and fractures. After initial concerns about RTSA longevity, indications were extended to primary osteoarthritis with glenoid deficiency, massive cuff tears in younger patients, fracture, tumour and failed anatomic total shoulder replacement. Traditional RTSA by Grammont has undergone a number of iterations such as glenoid lateralization, reduced neck-shaft angle, modular, stemless components and onlay systems. The incidence of complications such as dislocation, notching and acromial fractures has also evolved. Computer navigation, 3D planning and patient-specific implantation have been in use for several years and mixed-reality guided implantation is currently being trialled. Controversies in RTSA include lateralization, stemless humeral components, subscapularis repair and treatment of acromial fractures.
Cite this article: EFORT Open Rev 2021;6:189-201. DOI: 10.1302/2058-5241.6.200085
Collapse
Affiliation(s)
- Thomas Kozak
- Albany Health Campus, Albany, Australia.,Royal Perth Hospital, Perth, Australia
| | - Stefan Bauer
- Ensemble Hospitalier de la Côte, Morges, Switzerland
| | - Gilles Walch
- Hôpital Privé Jean-Mermoz, Centre Orthopédique Santy, Lyon, France
| | | | - William Blakeney
- Albany Health Campus, Albany, Australia.,Royal Perth Hospital, Perth, Australia
| |
Collapse
|
46
|
Flynn JN, Wijeratna M, Evans M, Lee S, Taylor DM, Hoy GA. Glenoid vault perforation in total shoulder arthroplasty: Do we need computer guidance? Shoulder Elbow 2021; 13:107-112. [PMID: 33717224 PMCID: PMC7905515 DOI: 10.1177/1758573219885062] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 09/29/2019] [Accepted: 10/02/2019] [Indexed: 11/15/2022]
Abstract
The proliferation of computer 3D simulation and computer-generated guides is aimed at minimizing perforation of the glenoid vault by glenoid pegs in shoulder arthroplasty, based on assumptions that perforation leads to worse outcomes by component loosening and potential failure. We evaluated outcomes of glenoid peg perforation testing the assumption that perforation produces worse results. Eighty-three shoulders underwent shoulder arthroplasty with pegged hybrid fixation (bone-ingrowth flanged central glenoid peg and peripheral cemented pegs) without precision signal injector guides or use of 3D planning software. Outcomes were determined by American Shoulder and Elbow Score and Oxford Shoulder Score. Fine slice CT determined the presence of vault perforation and the extent of lucent lines at the prosthesis-bone interface and bony morphology of the vault perforation. Follow-up was 46.7 months (24-99). Seven shoulders (8%) demonstrated perforation of glenoid vault. Bony ingrowth and cortical overgrowth occurred despite perforation, with no clinically significant differences in clinical or radiological outcomes in shoulders with and without glenoid vault perforation. None of these patients underwent revision surgery. Despite not utilizing computer planning and/or guides, 92% of implants did not perforate the glenoid vault. However, glenoid vault perforation in our series produced excellent outcomes with no increased risk of revision as a result of glenoid vault perforation.
Collapse
Affiliation(s)
- Jennifer N Flynn
- Austin Hospital, Heidelberg, Australia,Melbourne Orthopaedic Group, Windsor, Australia,Jennifer N Flynn, 26 Erin St, Richmond 3121, Australia.
| | | | - Matthew Evans
- Melbourne Orthopaedic Group, Windsor, Australia,Department of Surgery, Monash University, Melbourne, Australia
| | - Steven Lee
- The Avenue Radiology, Melbourne, Australia
| | - David McD Taylor
- Emergency Medicine Research, Austin Hospital, Melbourne, Australia,Department of Medicine, University of Melbourne, Melbourne, Australia
| | - Gregory A Hoy
- Austin Hospital, Heidelberg, Australia,Melbourne Orthopaedic Group, Windsor, Australia,Department of Surgery, Monash University, Melbourne, Australia
| |
Collapse
|
47
|
Glenoid Component Loosening in Anatomic Total Shoulder Arthroplasty: Association between Radiological Predictors and Clinical Parameters-An Observational Study. J Clin Med 2021; 10:jcm10020234. [PMID: 33440646 PMCID: PMC7826694 DOI: 10.3390/jcm10020234] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 12/18/2020] [Accepted: 01/04/2021] [Indexed: 11/17/2022] Open
Abstract
The mechanisms of glenoid component loosening in anatomic total shoulder arthroplasty (aTSA) are still unclear, and it remains undetermined which specific radiographic features are associated with clinical outcomes. Patients with primary osteoarthritis who underwent aTSA with a stemless implant and a pegged glenoid between January 2011 and December 2016 were extracted from a local registry. Anteroposterior radiographs were evaluated at six, 12, 24 months, and five years post-TSA for lateral humeral offset (LHO), joint gap (JG), acromiohumeral distance (AHD), and radiolucency (modified Franklin score); 147 patients were included. Mixed-model linear regression was used. Both constant score (CS) and subjective shoulder value (SSV) markedly decreased at five years follow-up compared to one year (p < 0.001 for both). AHD, LHO, and JG all showed a consistent and statistically significant decline over time, with the joint gap decreasing by half. Consistently, smaller JG and AHD were correlated with lower SSV (p = 0.03 and p = 0.07, respectively). Massive loosening was associated with a 14.5 points lower SSV (p < 0.01). Finally, narrowing of the JG was significantly correlated with increased radiolucency (p < 0.001) and tended toward worse SSV (p = 0.06). In summary, radiographic parameters displaying medialization and cranialization after aTSA with a cemented pegged glenoid are useful predictors of impaired shoulder function.
Collapse
|
48
|
Mariaux S, Obrist R, Farron A, Becce F, Terrier A. Is preoperative glenoid bone mineral density associated with aseptic glenoid implant loosening in anatomic total shoulder arthroplasty? BMC Musculoskelet Disord 2021; 22:49. [PMID: 33419412 PMCID: PMC7792203 DOI: 10.1186/s12891-020-03892-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 12/16/2020] [Indexed: 11/23/2022] Open
Abstract
Background Aseptic loosening of glenoid implants is the primary revision cause in anatomic total shoulder arthroplasty (aTSA). While supported by biomechanical studies, the impact of glenoid bone quality, more specifically bone mineral density (BMD), on aseptic glenoid loosening remains unclear. We hypothesized that lower preoperative glenoid BMD was associated with aseptic glenoid implant loosening in aTSA. Methods We retrospectively included 93 patients (69 females and 24 males; mean age, 69.2 years) who underwent preoperative non-arthrographic shoulder computed tomography (CT) scans and aTSA between 2002 and 2014. Preoperative glenoid BMD (CT numbers in Hounsfield unit) was measured in 3D using a reliable semi-automated quantitative method, in the following six contiguous volumes of interest (VOI): cortical, subchondral cortical plate (SC), subchondral trabecular, and three successive adjacent layers of trabecular bone. Univariate Cox regression was used to estimate the impact of preoperative glenoid BMD on aseptic glenoid implant loosening. We further compared 26 aseptic glenoid loosening patients with 56 matched control patients. Results Glenoid implant survival rates were 89% (95% confidence interval CI, 81–96%) and 57% (41–74%) at 5 and 10 years, respectively. Hazard ratios for the different glenoid VOIs ranged between 0.998 and 1.004 (95% CI [0.996, 1.007], p≥0.121). Only the SC VOI showed significantly lower CTn in the loosening group (622±104 HU) compared with the control group (658±88 HU) (p=0.048), though with a medium effect size (d=0.42). There were no significant differences in preoperative glenoid BMD in any other VOI between patients from the loosening and control groups. Conclusions Although the preoperative glenoid BMD was statistically significantly lower in the SC region of patients with aseptic glenoid implant loosening compared with controls, this single-VOI difference was only moderate. We are thus unable to prove that lower preoperative glenoid BMD is clearly associated with aseptic glenoid implant loosening in aTSA. However, due to its proven biomechanical role in glenoid implant survival, we recommend extending this study to larger CT datasets to further assess and better understand the impact of preoperative glenoid BMD on glenoid implant loosening/survival and aTSA outcome. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-020-03892-0.
Collapse
Affiliation(s)
- Sandrine Mariaux
- Service of Orthopedics and Traumatology, Lausanne University Hospital and University of Lausanne, Avenue Pierre-Decker 4, 1011, Lausanne, Switzerland
| | - Raphaël Obrist
- Laboratory of Biomechanical Orthopedics, Ecole Polytechnique Fédérale de Lausanne, Station 9, 1015, Lausanne, Switzerland
| | - Alain Farron
- Service of Orthopedics and Traumatology, Lausanne University Hospital and University of Lausanne, Avenue Pierre-Decker 4, 1011, Lausanne, Switzerland
| | - Fabio Becce
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Rue du Bugnon 46, 1011, Lausanne, Switzerland
| | - Alexandre Terrier
- Service of Orthopedics and Traumatology, Lausanne University Hospital and University of Lausanne, Avenue Pierre-Decker 4, 1011, Lausanne, Switzerland. .,Laboratory of Biomechanical Orthopedics, Ecole Polytechnique Fédérale de Lausanne, Station 9, 1015, Lausanne, Switzerland.
| |
Collapse
|
49
|
Karssiens TJ, Gill JR, Sunil Kumar KH, Sjolin SU. Clinical results and survivorship of the Mathys Affinis Short, Short Stem Total Shoulder Prosthesis. Bone Jt Open 2021; 2:58-65. [PMID: 33537677 PMCID: PMC7842163 DOI: 10.1302/2633-1462.21.bjo-2020-0184] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
AIMS The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. METHODS From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration. RESULTS Five shoulders underwent revision surgery (3.5%); three for rotator cuff failure, one for infection, and one for component malposition. Survivorship of the implant was 95.4% (95% confidence interval 90.1% to 97.9%) at five and nine years. Mean OSS improved significantly compared to preoperative values from 19.0 (1 to 35) to 43.3 (7 to 48) (p < 0.001). Radiological analysis was undertaken for 99 shoulders. This revealed humeral RLLs in one case (1%), glenoid RLLs in 15 cases (15.2%), and radiological rotator cuff failure in 22 cases (22.2%). CONCLUSION This prospective cohort study shows encouraging short- to mid-term survivorship and clinical and radiological results for the Mathys Affinis Short, Short Stem Total Shoulder Prosthesis.Level of Evidence: IVCite this article: Bone Jt Open 2021;2(1):58-65.
Collapse
Affiliation(s)
- Timothy James Karssiens
- Department of Trauma and Orthopaedics, West Suffolk NHS Foundation Trust, Bury St Edmunds, UK
| | - James Ritchie Gill
- Department of Trauma and Orthopaedics, West Suffolk NHS Foundation Trust, Bury St Edmunds, UK
| | - Karadi Hari Sunil Kumar
- Department of Trauma and Orthopaedics, Cambridge University Hospitals NHS Trust, Cambridge, UK
| | - Søren Upton Sjolin
- Department of Trauma and Orthopaedics, West Suffolk NHS Foundation Trust, Bury St Edmunds, UK
| |
Collapse
|
50
|
Impact of preoperative 3-dimensional planning and intraoperative navigation of shoulder arthroplasty on implant selection and operative time: a single surgeon's experience. J Shoulder Elbow Surg 2020; 29:2564-2570. [PMID: 33190756 DOI: 10.1016/j.jse.2020.03.041] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Revised: 03/03/2020] [Accepted: 03/11/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Preoperative 3D planning and intraoperative navigation for shoulder arthroplasty has recently gained interest because of the potential to enhance the surgeon's understanding of glenoid anatomy and improve the accuracy of glenoid component positioning. The purpose of our study was to assess the impact of preoperative 3D planning on the surgeon's selection of the glenoid component (standard vs. augmented) and compare duration of surgery with and without intraoperative navigation. METHODS We retrospectively analyzed 200 consecutive patients who underwent shoulder arthroplasty. The first group of 100 patients underwent shoulder arthroplasty using standard 2D preoperative planning based on standard radiographs and computed tomographic scans. The second group of 100 patients underwent shoulder arthroplasty using 3D preoperative planning and intraoperative navigation. Type of glenoid component and operative time were recorded in each case. RESULTS For the group of patients with standard preoperative planning, only 15 augmented glenoid components were used, whereas in the group of patients with 3D preoperative planning and navigation, 54 augments were used (P < .001). The operative time was 11 minutes longer for the procedures that used intraoperative navigation, compared with those that did not (P < .001). This difference diminished as the surgeon became more proficient with the navigation technique. CONCLUSION Use of preoperative 3D planning changes the surgeon's understanding of the patient's glenoid anatomy. In our study, using 3D planning increased the likelihood that the surgeon selected an augmented glenoid component compared with 2D planning. Intraoperative navigation slightly lengthened the duration of surgery, but this became insignificant as part of a learning curve within 6 months.
Collapse
|