1
|
Khan AZ, Maxwell MJ, Parrott RM, Bowler AR, Glass EA, Miller D, Vasconcellos D, Brownhill JR, Austin LS, Cuff DJ, Murthi AM, Smith MJ, Wiater JM, Jawa A. Effect of vitamin E-enhanced highly cross-linked polyethylene on wear rate and particle debris in anatomic total shoulder arthroplasty: a biomechanical comparison to ultrahigh-molecular-weight polyethylene. J Shoulder Elbow Surg 2024; 33:1465-1472. [PMID: 38182025 DOI: 10.1016/j.jse.2023.11.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 11/03/2023] [Accepted: 11/14/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND Particle-induced osteolysis resulting from polyethylene wear remains a source of implant failure in anatomic total shoulder designs. Modern polyethylene components are irradiated in an oxygen-free environment to induce cross-linking, but reducing the resulting free radicals with melting or heat annealing can compromise the component's mechanical properties. Vitamin E has been introduced as an adjuvant to thermal treatments. Anatomic shoulder arthroplasty models with a ceramic head component have demonstrated that vitamin E-enhanced polyethylene show improved wear compared with highly cross-linked polyethylene (HXLPE). This study aimed to assess the biomechanical wear properties and particle size characteristics of a novel vitamin E-enhanced highly cross-linked polyethylene (VEXPE) glenoid compared to a conventional ultrahigh-molecular-weight polyethylene (UHMWPE) glenoid against a cobalt chromium molybdenum (CoCrMo) head component. METHODS Biomechanical wear testing was performed to compare the VEXPE glenoid to UHMWPE glenoid with regard to pristine polyethylene wear and abrasive endurance against a polished CoCrMo alloy humeral head in an anatomic shoulder wear-simulation model. Cumulative mass loss (milligrams) was recorded, and wear rate calculated (milligrams per megacycle [Mc]). Under pristine wear conditions, particle analysis was performed, and functional biologic activity (FBA) was calculated to estimate particle debris osteolytic potential. In addition, 95% confidence intervals for all testing conditions were calculated. RESULTS The average pristine wear rate was statistically significantly lower for the VEXPE glenoid compared with the HXLPE glenoid (0.81 ± 0.64 mg/Mc vs. 7.00 ± 0.45 mg/Mc) (P < .05). Under abrasive wear conditions, the VEXPE glenoid had a statistically significant lower average wear rate compared with the UHMWPE glenoid comparator device (18.93 ± 5.80 mg/Mc vs. 40.47 ± 2.63 mg/Mc) (P < .05). The VEXPE glenoid demonstrated a statistically significant improvement in FBA compared with the HXLPE glenoid (0.21 ± 0.21 vs. 1.54 ± 0.49 (P < .05). CONCLUSIONS A new anatomic glenoid component with VEXPE demonstrated significantly improved pristine and abrasive wear properties with lower osteolytic particle debris potential compared with a conventional UHMWPE glenoid component. Vitamin E-enhanced polyethylene shows early promise in shoulder arthroplasty components. Long-term clinical and radiographic investigation needs to be performed to verify if these biomechanical wear properties translate to diminished long-term wear, osteolysis, and loosening.
Collapse
Affiliation(s)
- Adam Z Khan
- Northwest Permanente P.C., Portland, OR, USA
| | | | | | | | | | | | | | | | - Luke S Austin
- Department of Orthopaedic Surgery, The Rothman Institute, Philadelphia, PA, USA
| | - Derek J Cuff
- Suncoast Orthopaedic Surgery and Sports Medicine, Venice, FL, USA
| | | | - Matthew J Smith
- Department of Orthopedic Surgery, University of Missouri, Columbia, MO, USA
| | - J Michael Wiater
- Department of Orthopaedic Surgery, Beaumont Hospital, Royal Oak, MI, USA
| | - Andrew Jawa
- New England Baptist Hospital, Boston, MA, USA.
| |
Collapse
|
2
|
Salem AA, Taha DA, Nasr AA, El-Sagheer M, Daghash W, Taghian RA. Effect of vitamin E, D-limonene, and their combination on nulliparous rabbit reproductive performance. Anim Reprod Sci 2023; 259:107378. [PMID: 37989002 DOI: 10.1016/j.anireprosci.2023.107378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Accepted: 11/13/2023] [Indexed: 11/23/2023]
Abstract
Oxidative status is important in reproductive performance and using two natural antioxidants is more beneficial than one in nulliparous rabbits. The goal, effect of vitamin E (VitE), D-limonene (DL), and VitE+DL on maternal LBW (MLBW), conception (CR), pregnancy (PR), and kindling rates (KR), gestation length (GL), total litter size at birth (TLSB) and weaning (TLSW), live kits at birth (LKB) and weaning (LKW), dead kits at birth (DKB) and weaning (DKW), kits mortality rate at weaning (KMRW), Kit weight at birth (KWB) and weaning (KWW), total kit weight at birth (TKWB) and weaning (TKWW), and concentrations of progesterone (P4) and Malondialdehyde (MDA), during first two pregnancies. A total of 24 healthy female WNZ rabbits were randomly selected and assigned into four groups (6/each). Control (animals injected with 1.0 mL propylene glycol), VitE (60 mg IM injection/animal, 2X/week pre-mating and 3X post-mating until mid-pregnancy, DL (20 mg IM injection/animal, 2X/week pre-mating and 1X at mating, and VitE+DL (IM injection/animal with the same doses and times applied in VitE and DL groups. All animals were treated during 1st pregnancy only. The results confirmed that animals treated with VitE+DL gained significant maternal LBW in 1st pregnancy, reduced dead kit number at birth and kit mortality rate at weaning, increased live kits and total kit weight at birth and weaning in the two pregnancies, and also increased significantly kit weight at birth and weaning in the treatments than controls in the two pregnancies, and DL was greater in 1st pregnancy. Progesterone concentrations in mid-pregnancy rose significantly in VitE+DL during 1st pregnancy and DL in 2nd pregnancy. Malondialdehyde concentrations dropped significantly in VitE and VitE+DL in mid-pregnancy in the two pregnancies. Eventually, the integration of VitE and DL displayed their unique properties for improving productive and reproductive performance in nulliparous rabbits.
Collapse
Affiliation(s)
- Anas A Salem
- Animal Production Department, Fac. of Agriculture, Assiut University, Assiut, Egypt.
| | - Doaa A Taha
- Animal Production Department, Fac. of Agriculture, Assiut University, Assiut, Egypt.
| | - Asmaa Ae Nasr
- Pathology Department, Institute of Veterinary Health, Assiut, Egypt.
| | - Mohamed El-Sagheer
- Poultry Production Department, Fac. of Agriculture, Assiut University, Egypt
| | - Wael Daghash
- Animal Production Department, Fac. of Agriculture, Assiut University, Assiut, Egypt
| | - Raghda A Taghian
- Animal Production Department, Fac. of Agriculture, Assiut University, Assiut, Egypt
| |
Collapse
|
3
|
Spece H, Yarbrough RV, Kurtz SM. In Vivo Performance of Vitamin E Stabilized Polyethylene Implants for Total Hip Arthroplasty: A Review. J Arthroplasty 2022; 38:970-979. [PMID: 36481286 DOI: 10.1016/j.arth.2022.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/28/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Vitamin E stabilization was introduced to improve the oxidative stability, wear resistance, and mechanical properties of highly crosslinked polyethylene (HXLPE). In this literature review, we asked: (1) How has vitamin E-stabilized HXLPE (VEPE) performed in vivo for total hip arthroplasty (THA) and how does it compare with conventional ultra-high molecular weight polyethylene (UHMWPE) and HXLPE without vitamin E; and (2) Is there an apparent difference in the clinical performance of VEPE created by blending versus diffusion? METHODS We performed a systematic search of the literature according to the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines using PubMed and Embase. Included studies reported the in vivo behavior of VEPE in THA. We reviewed 41 studies. RESULTS For all studies that compared polyethylene with and without VE stabilization, outcomes for VEPE were either equivalent or superior to the control group (for HXLPE without VE and conventional UHMWPE controls, respectively). Hip insert wear rates were generally less than 0.1 mm/year and in most cases were less than 0.05 mm/year. No VEPE components were revised for osteolysis or adverse outcomes specific to VE incorporation. CONCLUSION Across the literature, we found that VEPE was reported to be clinically effective for THA applications, with much of the research indicating positive clinical outcomes and lower or equivalent wear rates compared to conventional UHMWPE and HXLPE controls without VE. Instances of early component fracture were reported, but have multiple potential causes. There is a gap in the literature for comparison of blended and diffused components, so the in vivo impact of VE incorporation method remains to be seen. Overall, this study provides a comprehensive summary of VEPE clinical performance for THA and may serve as a resource for future investigations.
Collapse
Affiliation(s)
- Hannah Spece
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA; Gyroid, LLC, Haddonfield, NJ
| | | | - Steven M Kurtz
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA; Gyroid, LLC, Haddonfield, NJ
| |
Collapse
|
4
|
The Effects of Vitamin E Analogues α-Tocopherol and γ-Tocotrienol on the Human Osteocyte Response to Ultra-High Molecular Weight Polyethylene Wear Particles. PROSTHESIS 2022. [DOI: 10.3390/prosthesis4030039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Polyethylene (PE) liners are a common bearing surface of orthopaedic prostheses. Wear particles of ultra-high molecular weight PE (UHMWPE) contribute to periprosthetic osteolysis, a major cause of aseptic loosening. Vitamin E is added to some PE liners to prevent oxidative degradation. Osteocytes, an important cell type for controlling both bone mineralisation and bone resorption, have been shown to respond UHMWPE particles by upregulating pro-osteoclastogenic and osteocytic osteolysis. Here, we examined the effects of the vitamin E analogues α-tocopherol and γ-tocotrienol alone or in the context of UHMWPE particles on human osteocyte gene expression and mineralisation behaviour. Human osteoblasts differentiated to an osteocyte-like stage were exposed to UHMWPE wear particles in the presence or absence of either α-Tocopherol or γ-Tocotrienol. Both α-Tocopherol and γ-Tocotrienol induced antioxidant-related gene expression. UHMWPE particles independently upregulated antioxidant gene expression, suggesting an effect of wear particles on oxidative stress. Both vitamin E analogues strongly induced OPG mRNA expression and γ-Tocotrienol also inhibited RANKL mRNA expression, resulting in a significantly reduced RANKL:OPG mRNA ratio (p < 0.01) overall. UHMWPE particles reversed the suppressive effect of α-Tocopherol but not of γ-Tocotrienol on this pro-osteoclastogenic index. UHMWPE particles also upregulated osteocytic-osteolysis related gene expression. Vitamin E analogues alone or in combination with UHMWPE particles also resulted in upregulation of these genes. Consistent with this, both vitamin E analogues promoted calcium release from mineralised cultures of osteocyte-like cells. Our findings suggest that while vitamin E may suppress osteocyte support of osteoclastogenesis in the presence of UHMWPE particles, the antioxidant effect may induce osteocytic osteolysis, which could promote periprosthetic osteolysis. It will be important to conduct further studies of vitamin E to determine the long-term effects of its inclusion in prosthetic materials.
Collapse
|
5
|
Hemmilä M, Laaksonen I, Matilainen M, Eskelinen A, Haapakoski J, Puhto AP, Kettunen J, Pamilo K, Mäkelä KT. Implant survival of 2,723 vitamin E-infused highly crosslinked polyethylene liners in total hip arthroplasty: data from the Finnish Arthroplasty Register. Acta Orthop 2021; 92:316-322. [PMID: 33517823 PMCID: PMC8231410 DOI: 10.1080/17453674.2021.1879513] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The use of crosslinked polyethylene in total hip arthroplasty (THA) has decreased wear remarkably. It has been suggested that the antioxidative effects of vitamin E may enhance the wear properties of polyethylene even further. This study evaluates revision rates between vitamin E-infused polyethylene liners (E1 and E-poly, ZimmerBiomet, Warsaw, IN, USA) versus moderately crosslinked polyethylene (ModXLPE) liners from the same manufacturer used in primary THA.Patients and methods - We conducted a study based on data from the Finnish Arthroplasty Register. The study group consisted of 2,723 THAs with a vitamin E-infused liner and a reference group of 2,707 THAs with a moderately crosslinked polyethylene liner. Survivorship, revision risk, and re-revision causes were compared between groups.Results - The 7-year survival of the vitamin E-infused polyethylene liner group and of the reference group with revision for any reason as the endpoint was comparable (94% [95% CI 92.9-94.9] and 93% [CI 91.9-93.9], respectively). The adjusted hazard ratio (HR) for any revision was similar between the groups (0.7 [CI 0.4-1.1]). When revision for aseptic loosening was studied as the endpoint, the survival for the study group was 99% (CI 98.6-99.4) and for the reference group 99% (CI 98.7-99.5), and the risk of revision was comparable between the study groups (HR 1.3 [CI 0.7-2.5]).Interpretation - After an observation period of 7 years vitamin E-infused liners shows results equal to results obtained with crosslinked polyethylene liners.
Collapse
Affiliation(s)
- Matias Hemmilä
- Department of Orthopaedic Surgery, University of Turku and Turku University Hospital, Turku; ,Correspondence:
| | - Inari Laaksonen
- Department of Orthopaedic Surgery, University of Turku and Turku University Hospital, Turku;
| | - Markus Matilainen
- Turku PET Centre, University of Turku and Turku University Hospital, Turku;
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement and Faculty of Medicine and Health Technologies, Tampere University, Tampere;
| | | | - Ari-Pekka Puhto
- Division of Operative Care, Department of Orthopaedic and Trauma Surgery, Oulu University Hospital, Oulu;
| | - Jukka Kettunen
- Department of Orthopaedics and Traumatology, Kuopio University Hospital, Kuopio, Finland
| | - Konsta Pamilo
- Coxa Hospital for Joint Replacement and Faculty of Medicine and Health Technologies, Tampere University, Tampere;
| | - Keijo T Mäkelä
- Department of Orthopaedic Surgery, University of Turku and Turku University Hospital, Turku;
| |
Collapse
|
6
|
Vitamin E-blended versus conventional polyethylene liners in prostheses : Prospective, randomized trial with 3-year follow-up. DER ORTHOPADE 2021; 49:1077-1085. [PMID: 31696260 DOI: 10.1007/s00132-019-03830-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
BACKGROUND Despite continuous technical improvements, polyethylene wear debris induced periprosthetic osteolysis remains the main cause for failure of hip arthroplasty. Progressive oxidation of polyethylene was identified as another risk factor for material failure. To overcome this problem, antioxidants such as vitamin E (alpha-tocopherol) were supplemented by diffusion into the latest generation of polyethylene liners. OBJECTIVE The purpose of the present study was to investigate the clinical outcome of patients treated with vitamin E blended highly cross-linked ultra-high molecular weight polyethylene liners (UHMWPE-XE) in comparison with conventional UHMWPE‑X liners by evaluating patient-reported outcome measures (PROM's) at 3‑year follow-up. METHODS A total of 143 patients were recruited into this prospective, randomized trial in our academic center. Three years after implantation, 101 patients were examined in the outpatient clinic for follow-up. Of these, 51 (50.5%) received UHMWPE-XE and 50 (49.5%) UHMWPE‑X liners. Clinical outcome was evaluated using Harris-Hip-Score (HHS) UCLA-Score and Hip Disability and Osteoarthritis Outcome Score (HOOS). RESULTS There was a significant improvement in all PROM's at one- and three-year follow-up compared to the status before implantation. PROM's did not differ significantly between the first and third year follow-up. Both liner groups showed an equal clinical outcome. CONCLUSION The present study demonstrates that the supplementation of vitamin E to polyethylene liners is reliable and safe without showing higher complication rates compared with conventional polyethylene liners. The shortterm clinical outcome of vitamin E-blended (UHMWPE‑XE) is equivalent to those of conventional highly cross-linked polyethylene liners.
Collapse
|
7
|
Wyatt MC, Roberton A, Foxall-Smi M, Beswick AD, Kunutsor SK, Whitehouse MR. Does vitamin E highly-crosslinked polyethylene convey an advantage in primary total hip replacement? A systematic review and meta-analysis. Hip Int 2020; 30:598-608. [PMID: 31213083 DOI: 10.1177/1120700019858335] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Vitamin E highly cross-linked polyethylene (HXLPE) was developed to reduce wear in total hip replacement (THR). This formal systematic review and meta-analysis aimed to provide independent synthesis of wear characteristics of Vitamin E treated HXLPE compared to HXPLE/UHMWPE. Secondary outcome measures were differences in revision rates and functional scores. METHODS We performed a formal systematic review as per PRISMA guidelines; literature searches were conducted on 14 November 2017 (MEDLINE, Embase on Ovid, and the Cochrane Library). We included randomised controlled trials, analyses of joint registries, and case-controlled studies of primary THR comparing cups with a vitamin E HXLPE bearing with bearing surfaces made from other types of polyethylene. Initial screening was performed by 2 independent assessors; disagreement resolved in discussion with a third reviewer. Studies were evaluated using the Cochrane risk of bias tool. Data extraction permitted meta-analysis. RESULTS 372 studies were identified on initial screening, 5 studies met the eligibility criteria. There was no significant heterogeneity between studies. There was variable risk of bias. At a mean of 35 (range 20-60) months, Vitamin E HXLPE had significant advantages over highly cross-linked polyethylene with regards total femoral head penetration (p = 0.004). Given the RSA measurement errors this may not be clinically significant.There were neither significant differences in revision rates nor Harris Hip Scores (p = 0.06). CONCLUSION At a minimum of 3 years follow-up there was reduced total femoral head penetration for vitamin E HXLPE over HXLPE. This bearing surface does not, as yet, have clinically significant advantages in terms of revision rates or patient function over HXLPE.
Collapse
Affiliation(s)
- Michael C Wyatt
- Musculoskeletal Research Unit, Southmead Hospital, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol
| | - Andrew Roberton
- Musculoskeletal Research Unit, Southmead Hospital, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol
| | - Michael Foxall-Smi
- Musculoskeletal Research Unit, Southmead Hospital, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol
| | - Andrew D Beswick
- Musculoskeletal Research Unit, Southmead Hospital, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol
| | - Setor K Kunutsor
- Musculoskeletal Research Unit, Southmead Hospital, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol
| | - Michael R Whitehouse
- Musculoskeletal Research Unit, Southmead Hospital, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol
| |
Collapse
|
8
|
Hameister R, Kaur C, Dheen ST, Lohmann CH, Singh G. Reactive oxygen/nitrogen species (ROS/RNS) and oxidative stress in arthroplasty. J Biomed Mater Res B Appl Biomater 2020; 108:2073-2087. [PMID: 31898397 DOI: 10.1002/jbm.b.34546] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 11/19/2019] [Accepted: 12/08/2019] [Indexed: 12/16/2022]
Abstract
The interplay between implant design, biomaterial characteristics, and the local microenvironment adjacent to the implant is of utmost importance for implant performance and success of the joint replacement surgery. Reactive oxygen and nitrogen species (ROS/RNS) are among the various factors affecting the host as well as the implant components. Excessive formation of ROS and RNS can lead to oxidative stress, a condition that is known to damage cells and tissues and also to affect signaling pathways. It may further compromise implant longevity by accelerating implant degradation, primarily through activation of inflammatory cells. In addition, wear products of metallic, ceramic, polyethylene, or bone cement origin may also generate oxidative stress themselves. This review outlines the generation of free radicals and oxidative stress in arthroplasty and provides a conceptual framework on its implications for soft tissue remodeling and bone resorption (osteolysis) as well as implant longevity. Key findings derived from cell culture studies, animal models, and patients' samples are presented. Strategies to control oxidative stress by implant design and antioxidants are explored and areas of controversy and challenges are highlighted. Finally, directions for future research are identified. A better understanding of the host-implant interplay and the role of free radicals and oxidative stress will help to evaluate therapeutic approaches and will ultimately improve implant performance in arthroplasty.
Collapse
Affiliation(s)
- Rita Hameister
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Charanjit Kaur
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Shaikali Thameem Dheen
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Gurpal Singh
- Centre for Orthopaedics Pte Ltd, Singapore, Singapore
| |
Collapse
|
9
|
Yao L, Li C, Li J. [Research progress in artificial metacarpophalangeal joint and interphalangeal joint prostheses]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2019; 33:1326-1330. [PMID: 31544447 DOI: 10.7507/1002-1892.201902015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To summarize the research progress in artificial metacarpophalangeal joint and interphalangeal joint prostheses. Methods The research literature on artificial metacarpophalangeal joint and interphalangeal joint prostheses at home and abroad was reviewed and summarized from anatomy, prosthesis design, and material development. Results The artificial joint replacement can correct deformity, relieve pain, and improve function immediately. In the past 50 years, many researches have focused on the design and material of prostheses and surgical technique of joint replacement. There are three types of prostheses, including hinged limit-type-prosthesis, semi-limit-type-prosthesis, and non-limit-type-prosthesis. The prostheses have their own advantages and disadvantages, the long-term effectiveness of joint replacement is not ideal. Conclusion The metacarpophalangeal joint and interphalangeal joint prostheses with more anatomical structure and biocompatible materials are needed.
Collapse
Affiliation(s)
- Ling Yao
- Department of Orthopedics, 920 Hospital of Joint Logistic Support Force of Chinese PLA, Kunming Yunnan, 650100, P.R.China;Department of Graduates, Kunming Medical University, Kunming Yunnan, 650500, P.R.China
| | - Chuan Li
- Department of Orthopedics, 920 Hospital of Joint Logistic Support Force of Chinese PLA, Kunming Yunnan, 650100, P.R.China
| | - Jun Li
- Department of Orthopedics, 920 Hospital of Joint Logistic Support Force of Chinese PLA, Kunming Yunnan, 650100,
| |
Collapse
|
10
|
The effect of vitamin E-enhanced cross-linked polyethylene on wear in shoulder arthroplasty-a wear simulator study. J Shoulder Elbow Surg 2019; 28:1771-1778. [PMID: 31029519 DOI: 10.1016/j.jse.2019.01.014] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Revised: 01/14/2019] [Accepted: 01/21/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Wear of the polyethylene glenoid component and subsequent particle-induced osteolysis remains one of the most important modes of failure of total shoulder arthroplasty. Vitamin E is added to polyethylene to act as an antioxidant to stabilize free radicals that exist as a byproduct of irradiation used to induce cross-linking. This study was performed to assess the in vitro performance of vitamin E-enhanced polyethylene compared with conventional polyethylene in a shoulder simulator model. METHODS Vitamin E-enhanced, highly cross-linked glenoid components were compared with conventional ultrahigh-molecular-weight polyethylene glenoids, both articulating with a ceramic humeral head component using a shoulder joint simulator over 500,000 cycles. Unaged and artificially aged comparisons were performed. Volumetric wear was assessed by gravimetric measurement, and wear particle analysis was also subsequently performed. RESULTS Vitamin E-enhanced polyethylene glenoid components were found to have significantly reduced wear rates compared with conventional polyethylene in both unaged (36% reduction) and artificially aged (49% reduction) comparisons. There were no differences detected in wear particle analysis between the 2 groups. CONCLUSION Vitamin E-enhanced polyethylene demonstrates improved wear compared with conventional polyethylene in both unaged and artificially aged comparisons and may have clinically relevant benefits.
Collapse
|
11
|
Takemura S, Minoda Y, Sugama R, Ohta Y, Nakamura S, Ueyama H, Nakamura H. Comparison of a vitamin E-infused highly crosslinked polyethylene insert and a conventional polyethylene insert for primary total knee arthroplasty at two years postoperatively. Bone Joint J 2019; 101-B:559-564. [PMID: 31039001 DOI: 10.1302/0301-620x.101b5.bjj-2018-1355.r1] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
AIMS The use of vitamin E-infused highly crosslinked polyethylene (HXLPE) in total knee prostheses is controversial. In this paper we have compared the clinical and radiological results between conventional polyethylene and vitamin E-infused HXLPE inserts in total knee arthroplasty (TKA). PATIENTS AND METHODS The study included 200 knees (175 patients) that underwent TKA using the same total knee prostheses. In all, 100 knees (77 patients) had a vitamin E-infused HXLPE insert (study group) and 100 knees (98 patients) had a conventional polyethylene insert (control group). There were no significant differences in age, sex, diagnosis, preoperative knee range of movement (ROM), and preoperative Knee Society Score (KSS) between the two groups. Clinical and radiological results were evaluated at two years postoperatively. RESULTS Differences in postoperative ROM and KSS were not statistically significant between the study and control groups. No knee exhibited osteolysis, aseptic loosening, or polyethylene failure. Additionally, there was no significant difference in the incidence of a radiolucent line between the two groups. One patient from the study group required irrigation and debridement, due to deep infection, at six months postoperatively. CONCLUSION Clinical results were comparable between vitamin E-infused HXLPE inserts and conventional polyethylene inserts at two years after TKA, without any significant clinical failure. Cite this article: Bone Joint J 2019;101-B:559-564.
Collapse
Affiliation(s)
- S Takemura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - Y Minoda
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - R Sugama
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - Y Ohta
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - S Nakamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - H Ueyama
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - H Nakamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
12
|
Ponzio DY, Weitzler L, deMeireles A, Esposito CI, Wright TM, Padgett DE. Antioxidant-stabilized highly crosslinked polyethylene in total knee arthroplasty. Bone Joint J 2018; 100-B:1330-1335. [DOI: 10.1302/0301-620x.100b10.bjj-2018-0061.r2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims The aim of this study was to evaluate the surface damage, the density of crosslinking, and oxidation in retrieved antioxidant-stabilized highly crosslinked polyethylene (A-XLPE) tibial inserts from total knee arthroplasty (TKA), and to compare the results with a matched cohort of standard remelted highly crosslinked polyethylene (XLPE) inserts. Materials and Methods A total of 19 A-XLPE tibial inserts were retrieved during revision TKA and matched to 18 retrieved XLPE inserts according to the demographics of the patients, with a mean length of implantation of 15 months (1 to 42). The percentage areas of PE damage on the articular surfaces and the modes of damage were measured. The density of crosslinking of the PE and oxidation were measured at loaded and unloaded regions on these surfaces. Results A-XLPE inserts had higher rates of burnishing and lower rates of pitting and scratching compared with XLPE. There were no differences in the density of crosslinking at loaded and unloaded regions. A-XLPE showed higher oxidation indices in the unloaded surface region compared with XLPE. There were no differences in the levels of oxidation in the loaded regions. Conclusion Retrieval analysis of A-XLPE did not reflect a clinically relevant difference in surface damage, density of crosslinking, or oxidation compared with XLPE tibial inserts at short-term evaluation. Cite this article: Bone Joint J 2018;100-B:1330–5.
Collapse
|
13
|
Ludwig KB, Chandrasekar V, Saylor DM, Van Citters DW, Reinitz SD, Forrey C, McDermott MK, Wickramasekara S, Janes DW. Characterizing the free volume of ultrahigh molecular weight polyethylene to predict diffusion coefficients in orthopedic liners. J Biomed Mater Res B Appl Biomater 2017; 106:2393-2402. [DOI: 10.1002/jbm.b.34045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Revised: 08/21/2017] [Accepted: 10/31/2017] [Indexed: 11/10/2022]
Affiliation(s)
- Kyle B. Ludwig
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | - Vaishnavi Chandrasekar
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | - David M. Saylor
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | | | - Steven D. Reinitz
- Thayer School of Engineering; Dartmouth College; Hanover New Hampshire 03755
| | - Christopher Forrey
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | - Martin K. McDermott
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | - Samanthi Wickramasekara
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | | |
Collapse
|
14
|
Currier BH, Van Citters DW. A Novel Technique for Assessing Antioxidant Concentration in Retrieved UHMWPE. Clin Orthop Relat Res 2017; 475:1356-1365. [PMID: 27334326 PMCID: PMC5384904 DOI: 10.1007/s11999-016-4939-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Antioxidants added to UHMWPE to prevent in vivo oxidation are important to the long-term performance of hip and knee arthroplasty. Diffused vitamin E antioxidant polyethylene raised questions about potential in vivo elution that could cause inflammatory reactions in periprosthetic tissues and also potentially leave the implant once again prone to oxidation. Currently, there is no information on the elution, if any, of antioxidants from implant polyethylene materials in vivo. QUESTIONS/PURPOSES (1) Do antioxidants, especially diffused vitamin E, elute from antioxidant polyethylene in vivo? (2) Can extraction of the retrieved antioxidant polyethylene (to remove absorbed species from the in vivo environment near the articular and nonarticular surfaces) improve the identification of antioxidant content? (3) Can actual antioxidant content be estimated from calculated antioxidant indices by accounting for ester content (from absorbed species) near the articular and nonarticular surfaces? METHODS An institutional review board-approved retrieval laboratory received 39 antioxidant polyethylene hip and knee retrievals at revision from 25 surgeons with in vivo time of 0.02 to 3.6 years (median, 1.3 years). These consecutive antioxidant polyethylene retrievals, received between May 2010 and February 2016, were made from three different antioxidant highly crosslinked polyethylene materials: diffused vitamin E, blended vitamin E, and hindered phenol antioxidant pentaerythritol tetrakis[3-(3,5-di-tert-butyl-4-hydroxyphenyl)] propionate (here and after referred to as PBHP). Retrievals were analyzed using Fourier transform infrared (FTIR) spectroscopy. Absorbed ester index (1725-1740 cm-1 normalized to 1365-1371 cm-1), and vitamin E index (1245-1275 cm-1) and PBHP index (1125-1150 cm-1), normalized to 1850-1985 cm-1, were defined. Microtomed thin sections of PBHP and vitamin E retrievals were hexane-extracted to remove absorbed species from the in vivo environment in an effort to improve identification of antioxidant content. Paired Student's t-tests were used to compare as-retrieved articular antioxidant index with expected antioxidant index (the bulk value for blended antioxidants where constant antioxidant content is expected throughout and the extrapolated original vitamin E concentration at the articular surface based on the as-manufactured vitamin E concentration gradient). Linear regression was used for each of the retrievals to evaluate the correlation of antioxidant index to ester content with the goal of extrapolation to the antioxidant index at zero ester content. RESULTS On average, vitamin E index at the articular surface (0.04 ± 0.03) was reduced compared with expected vitamin E index (0.09 ± 0.04; 95% confidence interval [CI] of the difference, 0.04-0.07; p < 0.001), and PBHP index at the articular surface (0.06 ± 0.02) was elevated compared with the average PBHP index from the bulk (0.03 ± 0.00; 95% CI of the difference, 0.03-0.05; p < 0.001). Extraction returned the PBHP index at the articular surface (0.03 ± 0.00) to bulk values (95% CI of the difference, -0.001 to 0.004; p = 0.326); diffused vitamin E was removed by extraction. Crossplots of vitamin E index and PBHP index with ester index showed significant (p < 0.001 for 32 of the 35 retrievals with sufficient data) linear trends (r ≥ 0.89) that allowed extrapolation of the articular surface antioxidant indices at zero absorbed ester index. CONCLUSIONS Absorbed esters from time in vivo caused erroneous values of antioxidant index to be calculated. However, hexane extraction to remove absorbed species also removed diffused vitamin E. Correlating antioxidant indices with ester content, measured by FTIR in unextracted antioxidant retrievals, provides a nonaltered method for estimating actual articular surface vitamin E index and demonstrates that there was no measurable elution in these short-term retrievals. CLINICAL RELEVANCE Assessing antioxidant content in retrieved polyethylene inserts is important to determine how much of the antioxidant remains in place to prevent oxidation of the polyethylene over time in vivo. Retrieval analyses reporting antioxidant content must account for absorbed species to be valid. Because standard hexane extraction removes both absorbed species and vitamin E from diffused vitamin E retrievals, the correlation method presented in this study is the recommended analysis alternative.
Collapse
Affiliation(s)
- Barbara H. Currier
- grid.254880.3Thayer School of Engineering, Dartmouth College, 14 Engineering Drive, Hanover, NH 03755 USA
| | - Douglas W. Van Citters
- grid.254880.3Thayer School of Engineering, Dartmouth College, 14 Engineering Drive, Hanover, NH 03755 USA
| |
Collapse
|
15
|
Muratoglu OK. CORR Insights ®: A Novel Technique for Assessing Antioxidant Concentration in Retrieved UHMWPE. Clin Orthop Relat Res 2017; 475:1366-1368. [PMID: 27637613 PMCID: PMC5384908 DOI: 10.1007/s11999-016-5070-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Accepted: 08/30/2016] [Indexed: 01/31/2023]
Affiliation(s)
- Orhun K. Muratoglu
- Orthopaedic Biomechanics/Biomaterials Lab, Massachusetts General Hospital, 55 Fruit Street, GRJ 1206, Boston, MA 02114 USA
| |
Collapse
|
16
|
Nebergall AK, Troelsen A, Rubash HE, Malchau H, Rolfson O, Greene ME. Five-Year Experience of Vitamin E-Diffused Highly Cross-Linked Polyethylene Wear in Total Hip Arthroplasty Assessed by Radiostereometric Analysis. J Arthroplasty 2016; 31:1251-1255. [PMID: 26777551 DOI: 10.1016/j.arth.2015.12.023] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2015] [Revised: 11/17/2015] [Accepted: 12/01/2015] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Vitamin E-diffused highly cross-linked polyethylene (VEPE) was developed to reduce oxidation without compromising mechanical strength. The purpose of this study was to evaluate VEPE in vivo using radiostereometric analysis (RSA) and patient-reported outcome measures (PROMs). METHODS Fifty-one hips were enrolled. Each patient received a VEPE liner, a porous titanium shell, and an uncemented stem with a 32-mm cobalt-chrome femoral head. Tantalum beads were inserted into the VEPE to measure femoral head penetration using RSA. RSA radiographs and PROMs were obtained preoperatively immediately after surgery, 6 months, 1, 2, 3, and 5 years after surgery. RESULTS Forty-seven hips returned at 3 years, and 42 hip at 5 years. The mean ± standard error of the mean proximal head penetration into the polyethylene was 0.06 ± 0.01 at 5 years. The amount of head penetration did not change significantly with increasing time in vivo. The mean ± standard error of the mean Harris Hip Score was 58 ± 2 preoperatively, which improved significantly to 93 ± 2 at 5 years (P < .001). CONCLUSION The head penetration into VEPE liners was low compared with non-VEPE at 5 years. After settling of the liners in the early period, no significant head penetration occurred from 2- to 5-year follow-up. All PROMs improved significantly from preoperative to postoperative and remained very favorable at 5 years. This study documents the longest-term evaluation of in vivo wear performance of VEPE.
Collapse
Affiliation(s)
- Audrey K Nebergall
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Anders Troelsen
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedics, Copenhagen University Hvidovre Hospital, Hvidovre, Denmark
| | - Harry E Rubash
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Henrik Malchau
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Ola Rolfson
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Department of Orthopaedics, Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Meridith E Greene
- Department of Orthopaedics, Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| |
Collapse
|
17
|
E-vitamin infused highly cross-linked polyethylene: RSA results from a randomised controlled trial using 32 mm and 36 mm ceramic heads. Hip Int 2015; 25:50-5. [PMID: 25633755 DOI: 10.5301/hipint.5000195] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/21/2014] [Indexed: 02/04/2023]
Abstract
BACKGROUND Polyethylene wear has been a major cause of revision of cementless total hip replacements. Highly cross-linked polyethylene has been developed to increase mechanical resistance to wear. However, cross-linking from irradiation of the polyethylene generates free radicals and these can oxidise in vivo and might over time alter the initial mechanical properties. Vitamin-E infused highly cross-linked polyethylene has been developed to reduce the amount of free radicals without compromising the mechanical properties. PURPOSE To measure wear of vitamin E infused highly cross-linked polyethylene and compare wear between 2 different head sizes. METHODS In a prospective randomised study between 32 mm and 36 mm Biolox® delta heads in 50 hips we analysed the in vivo wear of the E-poly™ with markerless radiostereometry. RESULTS Mean (95% CI) wear for the total material was 0.041 mm (0.015-0.066) in the vertical direction and 0.177 mm (0.155-0.200) in the total 3D direction. After the anticipated period of bedding-in we found no statistically significant differences in wear from three months to 2 years in vertical and total 3D directions. Although statistical significant differences between 32 mm and 36 mm heads were found in the total 3D direction we cannot conclude that there are significant clinical important differences in wear comparing these head sizes. CONCLUSIONS This study shows promising early results with very low wear, even for 36 mm heads, but long term follow-up is necessary to evaluate if this polyethylene will provide low wear and good mechanical properties in the long-term.
Collapse
|
18
|
Gigante A, Bottegoni C, Ragone V, Banci L. Effectiveness of Vitamin-E-Doped Polyethylene in Joint Replacement: A Literature Review. J Funct Biomater 2015; 6:889-900. [PMID: 26371052 PMCID: PMC4598683 DOI: 10.3390/jfb6030889] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Revised: 07/24/2015] [Accepted: 08/08/2015] [Indexed: 12/25/2022] Open
Abstract
Since polyethylene is one of the most frequently used biomaterials, such as in bearing components in joint arthroplasty, strong efforts have been made to improve the design and material properties over the last decades. Antioxidants, such as vitamin-E, seem to be a promising alternative to further increase durability and reduce polyethylene wear and degradation in the long-term. Nevertheless, even if several promising in vitro results are available, there is yet no clinical evidence that vitamin-E polyethylenes show these advantages in vivo. The aim of this paper was to provide a comprehensive overview on the current knowledge regarding the biological and mechanical proprieties of this biomaterial, underlying the in vitro and in vivo evidence for effectiveness of vitamin-E-doped polyethylene in joint arthroplasty.
Collapse
Affiliation(s)
- Antonio Gigante
- Clinical Orthopaedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, via Tronto 10/A, 60126 Ancona, Italy.
| | - Carlo Bottegoni
- Clinical Orthopaedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, via Tronto 10/A, 60126 Ancona, Italy.
| | - Vincenza Ragone
- Research and Development Department, Permedica S.p.A., via Como 38, 23807 Merate (LC), Italy.
| | - Lorenzo Banci
- Research and Development Department, Permedica S.p.A., via Como 38, 23807 Merate (LC), Italy.
| |
Collapse
|
19
|
Rowell SL, Muratoglu OK. Investigation of surgically retrieved, vitamin E-stabilized, crosslinked UHMWPE implants after short-termin vivoservice. J Biomed Mater Res B Appl Biomater 2015; 104:1132-40. [DOI: 10.1002/jbm.b.33465] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2014] [Revised: 01/30/2015] [Accepted: 05/07/2015] [Indexed: 12/29/2022]
Affiliation(s)
- Shannon L. Rowell
- Harris Orthopaedics Laboratory; Massachusetts General Hospital; Boston MA
| | - Orhun K. Muratoglu
- Harris Orthopaedics Laboratory; Massachusetts General Hospital; Boston MA
- Department of Orthopaedic Surgery; Harvard Medical School; Boston MA
| |
Collapse
|
20
|
Huang CH, Lu YC, Chang TK, Hsiao IL, Su YC, Yeh ST, Fang HW, Huang CH. In vivo biological response to highly cross-linked and vitamin e-doped polyethylene--a particle-Induced osteolysis animal study. J Biomed Mater Res B Appl Biomater 2015; 104:561-7. [PMID: 25952769 DOI: 10.1002/jbm.b.33426] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2014] [Revised: 03/06/2015] [Accepted: 03/27/2015] [Indexed: 01/13/2023]
Abstract
Polyethylene particle-induced osteolysis is the primary limitation in the long-term success of total joint replacement with conventional ultra high molecular weight polyethylene (UHMWPE). Highly cross-linked polyethylene (HXLPE) and vitamin E-doped cross-linked polyethylene (VE-HXLPE) have been developed to increase the wear resistance of joint surfaces. However, very few studies have reported on the incidence of particle-induced osteolysis for these novel materials. The aim of this study was to use a particle-induced osteolysis animal model to compare the in vivo biological response to different polymer particles. Three commercially available polymers (UHMWPE, HXLPE, and VE-HXLPE) were compared. Osseous properties including the bone volume relative to the tissue volume (BV/TV), trabecular thickness (Tb. Th), and bone mineral density (BMD) were examined using micro computed tomography. Histological analysis was used to observe tissue inflammation in each group. This study demonstrated that the osseous properties and noticeable inflammatory reactions were obviously decreased in the HXLPE group. When compared with the sham group, a decrease of 12.7% was found in BV/TV, 9.6% in BMD and 8.3% in Tb.Th for the HXLPE group. The heightened inflammatory response in the HXLPE group could be due to its smaller size and greater amount of implanted particles. Vitamin E diffused in vivo may not affect the inflammatory and osteolytic responses in this model. The morphological size and total cumulative amount of implanted particles could be critical factors in determining the biological response.
Collapse
Affiliation(s)
- Chang-Hung Huang
- Biomechanics Research Laboratory, Department of Medical Research, MacKay Memorial Hospital (MMH), Taipei, Taiwan.,Institue of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan
| | - Yung-Chang Lu
- Biomechanics Research Laboratory, Department of Medical Research, MacKay Memorial Hospital (MMH), Taipei, Taiwan.,Department of Orthopaedic Surgery, MMH, Taipei, Taiwan.,Department of Cosmetic Application and Management, MacKay Junior College of Medicine, Nursing and Management, Taipei, Taiwan
| | - Ting-Kuo Chang
- Biomechanics Research Laboratory, Department of Medical Research, MacKay Memorial Hospital (MMH), Taipei, Taiwan.,Institue of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan.,Department of Orthopaedic Surgery, MMH, Taipei, Taiwan
| | - I-Lin Hsiao
- Biomechanics Research Laboratory, Department of Medical Research, MacKay Memorial Hospital (MMH), Taipei, Taiwan
| | - Yi-Ching Su
- Department of Chemical Engineering and Biotechnology and Institute of Biotechnology, National Taipei University of Technology, Taipei, Taiwan
| | - Shu-Ting Yeh
- Biomechanics Research Laboratory, Department of Medical Research, MacKay Memorial Hospital (MMH), Taipei, Taiwan
| | - Hsu-Wei Fang
- Department of Chemical Engineering and Biotechnology and Institute of Biotechnology, National Taipei University of Technology, Taipei, Taiwan
| | - Chun-Hsiung Huang
- Institue of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan.,Department of Orthopaedic Surgery, MMH, Taipei, Taiwan
| |
Collapse
|
21
|
Halma JJ, Eshuis R, Vogely HC, van Gaalen SM, de Gast A. An uncemented iso-elastic monoblock acetabular component: preliminary results. J Arthroplasty 2015; 30:615-21. [PMID: 25496930 DOI: 10.1016/j.arth.2014.11.017] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2014] [Revised: 10/29/2014] [Accepted: 11/10/2014] [Indexed: 02/01/2023] Open
Abstract
Little is known about the clinical application of highly cross-linked polyethylene (HXLPE) blended with vitamin E. This study evaluates an uncemented iso-elastic monoblock cup with vitamin E blended HXLPE. 112 patients were followed up for 2years. 95.5% completed the follow-up. The mean VAS score for patient satisfaction was 8.8 and the mean Harris Hip Score was 94.2. In 7 cases initial gaps behind the cup were observed, which disappeared completely during follow-up in 6 cases. The mean femoral head penetration rate was 0.055mm/year. No adverse reactions or abnormal mechanical behavior was observed with the short term use of vitamin E blended HXLPE. This study shows the promising performance of this cup and confirms the potential of vitamin E blended HXLPE.
Collapse
Affiliation(s)
- Jelle J Halma
- Clinical Orthopedic Research Center-midden Nederland (CORC-mN) Department of Orthopedics, Diakonessenhuis Hospital, Utrecht, The Netherlands
| | - Rienk Eshuis
- Clinical Orthopedic Research Center-midden Nederland (CORC-mN) Department of Orthopedics, Diakonessenhuis Hospital, Utrecht, The Netherlands
| | - H Charles Vogely
- Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Steven M van Gaalen
- Clinical Orthopedic Research Center-midden Nederland (CORC-mN) Department of Orthopedics, Diakonessenhuis Hospital, Utrecht, The Netherlands
| | - Arthur de Gast
- Clinical Orthopedic Research Center-midden Nederland (CORC-mN) Department of Orthopedics, Diakonessenhuis Hospital, Utrecht, The Netherlands
| |
Collapse
|
22
|
Bichara DA, Malchau E, Sillesen NH, Cakmak S, Nielsen GP, Muratoglu OK. Vitamin E-diffused highly cross-linked UHMWPE particles induce less osteolysis compared to highly cross-linked virgin UHMWPE particles in vivo. J Arthroplasty 2014; 29:232-7. [PMID: 24998319 DOI: 10.1016/j.arth.2014.03.044] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Revised: 01/23/2014] [Accepted: 03/14/2014] [Indexed: 02/01/2023] Open
Abstract
Recent in vitro findings suggest that UHMWPE wear particles containing vitamin E (VE) may have reduced biologic activity and decreased osteolytic potential. We hypothesized that particles from VE-stabilized, radiation cross-linked UHMWPE would cause less osteolysis in a murine calvarial bone model when compared to virgin gamma irradiated cross-linked UHMWPE. Groups received equal amount of particulate debris overlaying the calvarium for 10 days. Calvarial bone was examined using high resolution micro-CT and histomorphometric analyses. There was a statistically significant difference between virgin (12.2%±8%) and VE-UHMWPE (3%±1.4%) groups in regards to bone resorption (P=0.005) and inflammatory fibrous tissue overlaying the calvaria (0.48 vs. 0.20, P<0.0001). These results suggest that VE-UHMWPE particles have reduced osteolytic potential in vivo when compared to virgin UHMWPE.
Collapse
Affiliation(s)
- David A Bichara
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts
| | - Erik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Nanna H Sillesen
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - Selami Cakmak
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts
| | - G Petur Nielsen
- Harvard Medical School, Boston, Massachusetts; Bone and Soft Tissue Pathology, Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts
| | - Orhun K Muratoglu
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
23
|
Jäger M, van Wasen A, Warwas S, Landgraeber S, Haversath M, Group V. A multicenter approach evaluating the impact of vitamin e-blended polyethylene in cementless total hip replacement. Orthop Rev (Pavia) 2014; 6:5285. [PMID: 25002933 PMCID: PMC4083306 DOI: 10.4081/or.2014.5285] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2014] [Accepted: 02/07/2014] [Indexed: 11/23/2022] Open
Abstract
Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising, there is yet no clinical evidence that the new material shows these advantages in vivo. To answer the question if vitamin-E enhanced ultra-high molecular weight polyethylene (UHMWPE) is able to improve long-term survivorship of cementless total hip arthroplasty we initiated a randomized long-term multicenter trial. Designed as a superiority study, the oxidation index assessed in retrieval analyses of explanted liners was chosen as primary parameter. Radiographic results (wear rate, osteolysis, radiolucency) and functional outcome (Harris Hip Scores, University of California-Los Angeles, Hip Disability and Osteoarthritis Outcome Score, Visual Analogue Scale) will serve as secondary parameters. Patients with the indication for a cementless total hip arthroplasty will be asked to participate in the study and will be randomized to either receive a standard hip replacement with a highly cross-linked UHMWPE-X liner or a highly cross-linked vitamin-E supplemented UHMWPE-XE liner. The follow-up will be 15 years, with evaluation after 5, 10 and 15 years. The controlled randomized study has been designed to determine if Vitamin-E supplemented highly cross-linked polyethylene liners are superior to standard XLPE liners in cementless total hip arthroplasty. While several studies have been started to evaluate the influence of vitamin-E, most of them evaluate wear rates and functional results. The approach used for this multicenter study, to analyze the oxidation status of retrieved implants, should make it possible to directly evaluate the ageing process and development of the implant material itself over a time period of 15 years.
Collapse
Affiliation(s)
- Marcus Jäger
- Orthopaedic Department, University of Duisburg-Essen, University Hospital Essen ; Tuttlingen, Germany
| | - Andrea van Wasen
- Orthopaedic Department, University of Duisburg-Essen, University Hospital Essen ; Tuttlingen, Germany
| | - Sebastian Warwas
- Orthopaedic Department, University of Duisburg-Essen, University Hospital Essen ; Tuttlingen, Germany
| | - Stefan Landgraeber
- Orthopaedic Department, University of Duisburg-Essen, University Hospital Essen ; Tuttlingen, Germany
| | - Marcel Haversath
- Orthopaedic Department, University of Duisburg-Essen, University Hospital Essen ; Tuttlingen, Germany
| | - Vitas Group
- B. Braun Melsungen AG, Aesculap Division , Tuttlingen, Germany
| |
Collapse
|
24
|
Oral E, Neils AL, Lyons C, Fung M, Doshi B, Muratoglu OK. Surface cross-linked UHMWPE can enable the use of larger femoral heads in total joints. J Orthop Res 2013; 31:59-66. [PMID: 22847503 DOI: 10.1002/jor.22195] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2012] [Accepted: 06/25/2012] [Indexed: 02/04/2023]
Abstract
Limiting cross-linking to the articular surfaces of ultrahigh molecular weight polyethylene (UHMWPE) to increase wear resistance while preventing detrimental effects of cross-linking on mechanical strength has been a desirable goal. A surface cross-linked UHMWPE can be achieved by blending UHMWPE with a free radical scavenger, such as vitamin E, consolidating the blend into an implant shape, extracting the vitamin E from the surface, and radiation cross-linking the surface extracted blend. This process results in high cross-link density in the vitamin E-depleted surface region because vitamin E hinders cross-linking during irradiation. In this study, we described the properties of successful extraction media and the manipulation of the wear and mechanical properties of extracted, irradiated blends. We showed that these formulations could have similar wear and significantly improved mechanical properties compared to currently available highly cross-linked UHMWPEs. We believe that these materials can enable thinner implant forms and more anatomical designs in joint arthroplasty and may provide a feasible alternative to metal-on-metal implants.
Collapse
Affiliation(s)
- Ebru Oral
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, Massachusetts, USA.
| | | | | | | | | | | |
Collapse
|
25
|
Abstract
An international faculty of orthopaedic surgeons presented their work on the current challenges in hip surgery at the London Hip Meeting which was attended by over 400 delegates. The topics covered included femoroacetabular impingement, thromboembolic phenomena associated with hip surgery, bearing surfaces (including metal-on-metal articulations), outcomes of hip replacement surgery and revision hip replacement. We present a concise report of the current opinions on hip surgery from this meeting with appropriate references to the current literature.
Collapse
Affiliation(s)
- F. S. Haddad
- University College Hospital, Department
of Trauma and Orthopaedics, 235 Euston Road, London
NW1 2BU, UK
| | - S. Konan
- NE Thames Orthopaedic Rotation, London,
UK
| |
Collapse
|
26
|
Abstract
BACKGROUND Osteolysis due to wear of UHMWPE limits the longevity of joint arthroplasty. Oxidative degradation of UHMWPE gamma-sterilized in air increases its wear while decreasing mechanical strength. Vitamin E stabilization of UHMWPE was proposed to improve oxidation resistance while maintaining wear resistance and fatigue strength. QUESTIONS/PURPOSES We reviewed the preclinical research on the development and testing of vitamin E-stabilized UHMWPE with the following questions in mind: (1) What is the rationale behind protecting irradiated UHMWPE against oxidation by vitamin E? (2) What are the effects of vitamin E on the microstructure, tribologic, and mechanical properties of irradiated UHMWPE? (3) Is vitamin E expected to affect the periprosthetic tissue negatively? METHODS We performed searches in PubMed, Scopus, and Science Citation Index to review the development of vitamin E-stabilized UHMWPEs and their feasibility as clinical implants. RESULTS The rationale for using vitamin E in UHMWPE was twofold: improving oxidation resistance of irradiated UHMWPEs and fatigue strength of irradiated UHMWPEs with an alternative to postirradiation melting. Vitamin E-stabilized UHMWPE showed oxidation resistance superior to that of irradiated UHMWPEs with detectable residual free radicals. It showed equivalent wear and improved mechanical strength compared to irradiated and melted UHMWPE. The biocompatibility was confirmed by simulating elution, if any, of the antioxidant from implants. CONCLUSIONS Vitamin E-stabilized UHMWPE offers a joint arthroplasty technology with good mechanical, wear, and oxidation properties. CLINICAL RELEVANCE Vitamin E-stabilized, irradiated UHMWPEs were recently introduced clinically. The rationale behind using vitamin E and in vitro tests comparing its performance to older materials are of great interest for improving longevity of joint arthroplasties.
Collapse
Affiliation(s)
- Pierangiola Bracco
- Dipartimento di Chimica IFM and NIS Centre of Excellence, Università di Torino, Via Pietro Guria, 7, 10125 Torino, Italy
| | - Ebru Oral
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA USA
| |
Collapse
|
27
|
Oral E, Muratoglu OK. Vitamin E diffused, highly crosslinked UHMWPE: a review. INTERNATIONAL ORTHOPAEDICS 2010; 35:215-23. [PMID: 21120476 DOI: 10.1007/s00264-010-1161-y] [Citation(s) in RCA: 142] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2010] [Revised: 11/02/2010] [Accepted: 11/02/2010] [Indexed: 11/30/2022]
Abstract
Highly crosslinked UHMWPE has become the bearing surface of choice in total hip arthroplasty. First generation crosslinked UHMWPEs, clinically introduced in the 1990s, show significant improvements compared to gamma sterilised, conventional UHMWPE in decreasing wear and osteolysis. These crosslinked UHMWPEs were thermally treated (annealed or melted) after irradiation to improve their oxidation resistance. While annealing resulted in the retention of some oxidation potential, post-irradiation melted UHMWPEs had reduced fatigue strength due to the crystallinity loss during melting. Thus, the stabilisation of radiation crosslinked UHMWPEs by the diffusion of the antioxidant vitamin E was developed to obtain oxidation resistance with improved fatigue strength by avoiding post-irradiation melting. A two-step process was developed to incorporate vitamin E into irradiated UHMWPE by diffusion to obtain a uniform concentration profile. Against accelerated and real-time aging in vitro, this material showed superior oxidation resistance to UHMWPEs with residual free radicals. The fatigue strength was improved compared to irradiated and melted UHMWPEs crosslinked using the same irradiation dose. Several adverse testing schemes simulating impingement showed satisfactory behaviour. Peri-prosthetic tissue reaction to vitamin E was evaluated in rabbits and any effects of vitamin E on device fixation were evaluated in a canine model, both of which showed no detrimental effects of the inclusion of vitamin E in crosslinked UHMWPE. Irradiated, vitamin E-diffused, and gamma sterilised UHMWPEs have been in clinical use in hips since 2007 and in knees since 2008. The clinical outcome of this material will be apparent from the results of prospective, randomised clinical studies.
Collapse
Affiliation(s)
- Ebru Oral
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit St. GRJ 1206, Boston, MA 02114, USA.
| | | |
Collapse
|