1
|
Tietz F, Adams I, Lücke E, Schreiber J. Inhalation Devices in 7- to 15-Year-Old Children with Asthma - A Patient Preference Study. Patient Prefer Adherence 2023; 17:951-959. [PMID: 37038436 PMCID: PMC10082580 DOI: 10.2147/ppa.s381486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 01/11/2023] [Indexed: 04/12/2023] Open
Abstract
Background Inhalation therapy is the cornerstone of treatment of bronchial asthma. A patient-specific selection of inhalation devices is necessary, as preference for a device plays an important role in terms of error rates in handling and adherence to therapy. However, there is no industry-independent study providing information on children's preferences for common inhaler types. The aim of the present study was to investigate the preference of asthmatic children for inhaler types commonly used in Germany. The effects of age, gender and the type of school visited on device preferences as well as the frequency of patient education and the role of health care providers in the choice for an inhaler were investigated. Methods Eighty children were included in this prospective cross-sectional study (age: 10.87 ± 2.62 years). The analysis was based on a questionnaire and validated checklists. All participants tested the use of nine placebo inhalers (Breezhaler, Diskus, Respimat, Spiromax, Turbohaler, Autohaler, metered-dose inhaler, Easyhaler and Novolizer) in a randomized order. For each device, patients were asked to assess handling, rate different device characteristics and name the device they would prefer most or least. Results The most favored device was the Novolizer. Moreover, the Spiromax scored highest in numerous categories such as suitability in emergencies and "easiest" device to use. Patient preferences with respect to the addressed inhaler features were not significantly related to age, gender or school type. Conclusion The Novolizer and the Spiromax showed higher preference in pediatric patients as compared to other tested devices. Overall, there were significant differences in terms of preference when comparing the tested inhalers in different aspects.
Collapse
Affiliation(s)
- Franziska Tietz
- Department of Pneumonology, University Medicine, Magdeburg, Germany
| | - Ines Adams
- Department of Pediatrics, University Medicine, Magdeburg, Germany
| | - Eva Lücke
- Department of Pneumonology, University Medicine, Magdeburg, Germany
| | - Jens Schreiber
- Department of Pneumonology, University Medicine, Magdeburg, Germany
- Correspondence: Jens Schreiber, Department of Pneumology, University Medicine Magdeburg, Leipziger Straße 44, Magdeburg, 39120, Germany, Tel +49 391 67 15421, Fax +49 391 67 13356, Email
| |
Collapse
|
2
|
Matuszak M, Ochowiak M, Włodarczak S, Krupińska A, Doligalski M. State-of-the-Art Review of The Application and Development of Various Methods of Aerosol Therapy. Int J Pharm 2021; 614:121432. [PMID: 34971755 DOI: 10.1016/j.ijpharm.2021.121432] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 12/09/2021] [Accepted: 12/23/2021] [Indexed: 12/23/2022]
Abstract
Aerosol therapy is a rapidly developing field of science. Due to a number of advantages, the administration of drugs to the body with the use of aerosol therapy is becoming more and more popular. Spraying drugs into the patient's lungs has a significant advantage over other methods of administering drugs to the body, including injection and oral methods. In order to conduct proper and effective aerosol therapy, it is necessary to become familiar with the basic principles and applications of aerosol therapy under various conditions. The effectiveness of inhalation depends on many factors, but most of all on: the physicochemical properties of the sprayed system, the design of the medical inhaler and its correct application, the dynamics of inhalation (i.e. the frequency of breathing and the volume of inhaled air). It is worth emphasizing that respiratory system diseases are one of the most frequently occurring and fastest growing diseases in the world. Accordingly, in recent years, a significant increase in the number of new spraying devices and pharmaceutical drugs for spraying has appeared on the market. It should also be remembered that the process of spraying a liquid is a complicated and complex process, and its efficiency is very often characterized by the use of micro- and macro parameters (including average droplet diameters or the spectrum of droplet diameter distribution). In order to determine the effectiveness of the atomization process and in the delivery of drugs to the patient's respiratory tract, the analysis of the size of the generated aerosol droplets is most often performed. Based on the proposed literature review, it has been shown that many papers dealt with the issues related to aerosol therapy, the selection of an appropriate spraying device, the possibility of modifying the spraying devices in order to increase the effectiveness of inhalation, and the possibility of occurrence of certain discrepancies resulting from the use of various measurement methods to determine the characteristics of the generated aerosol. The literature review presented in the paper was prepared in order to better understand the spraying process. Moreover, it can be helpful in choosing the right medical inhaler for a given liquid with specific rheological properties. The experimental data contained in this study are of great cognitive importance and may be of interest to entities involved in pharmaceutical product engineering (in particular in the case of the production of drugs containing liquids with complex rheological properties).
Collapse
Affiliation(s)
- M Matuszak
- Faculty of Chemical Technology, Poznan University of Technology, Institute of Chemical Technology and Engineering, 4 Berdychowo Street, 60-965 Poznan, Poland.
| | - M Ochowiak
- Faculty of Chemical Technology, Poznan University of Technology, Institute of Chemical Technology and Engineering, 4 Berdychowo Street, 60-965 Poznan, Poland
| | - S Włodarczak
- Faculty of Chemical Technology, Poznan University of Technology, Institute of Chemical Technology and Engineering, 4 Berdychowo Street, 60-965 Poznan, Poland
| | - A Krupińska
- Faculty of Chemical Technology, Poznan University of Technology, Institute of Chemical Technology and Engineering, 4 Berdychowo Street, 60-965 Poznan, Poland
| | - M Doligalski
- Faculty of Computer, Electrical and Control Engineering, University of Zielona Góra, 4a Szafrana Street, 65-516 Zielona Góra, Poland
| |
Collapse
|
3
|
Damiański P, Kardas G, Panek M, Kuna P, Kupczyk M. Improving the risk-to-benefit ratio of inhaled corticosteroids through delivery and dose: current progress and future directions. Expert Opin Drug Saf 2021; 21:499-515. [PMID: 34720035 DOI: 10.1080/14740338.2022.1999926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION Inhaled corticosteroids (ICS) are known to increase the risk of systemic and local adverse effects, especially with high doses and long-term use. Hence, considerable resources are invested to improve pharmacokinetic/pharmacodynamic (PK/PD) properties of ICS, effective delivery systems and novel combination therapies to enhance the risk-to-benefit ratio of ICS. AREAS COVERED There is an unmet need for new solutions to achieve optimal clinical outcomes with minimal dose of ICS. This paper gives an overview of novel treatment strategies regarding the safety of ICS therapy on the basis of the three most recent molecules introduced to our everyday clinical practice - ciclesonide, mometasone furoate, and fluticasone furoate. Advances in aerosol devices and new areas of inhalation therapy are also discussed. EXPERT OPINION Current progress in improving the risk-to-benefit ratio of ICS through dose and delivery probably established pathways for further developments. This applies both to the improvement of the PK/PD properties of ICS molecules but also includes technical aspects that lead to simplified applicability of the device with simultaneous optimal drug deposition in the lungs. Indubitably, the future of medicine lies not only in the development of new molecules but also in technology and digital revolution.
Collapse
Affiliation(s)
- Piotr Damiański
- Clinical Department of Internal Medicine, Asthma and Allergy, Medical University of Lodz, Lodz, Poland
| | - Grzegorz Kardas
- Clinical Department of Internal Medicine, Asthma and Allergy, Medical University of Lodz, Lodz, Poland
| | - Michał Panek
- Clinical Department of Internal Medicine, Asthma and Allergy, Medical University of Lodz, Lodz, Poland
| | - Piotr Kuna
- Clinical Department of Internal Medicine, Asthma and Allergy, Medical University of Lodz, Lodz, Poland
| | - Maciej Kupczyk
- Clinical Department of Internal Medicine, Asthma and Allergy, Medical University of Lodz, Lodz, Poland
| |
Collapse
|
4
|
The Respimat ® Soft Mist Inhaler: Implications of Drug Delivery Characteristics for Patients. Clin Drug Investig 2020; 39:1021-1030. [PMID: 31377981 PMCID: PMC6800401 DOI: 10.1007/s40261-019-00835-z] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Successful treatment for respiratory diseases relies on effective delivery of medication to the lungs using an inhalation device. Different inhalers have distinct characteristics affecting drug administration and patient adherence, which can impact clinical outcomes. We report on the development of the Respimat® soft mist inhaler (SMI) and compare key attributes with metered-dose inhalers (MDIs) and dry powder inhalers (DPIs). The Respimat SMI, a pocket-sized device generating a single-breath, inhalable aerosol, was designed to enhance drug delivery to the lungs, reduce the requirements for patient coordination and inspiratory effort, and improve the patients’ experience and ease of use. The drug deposition profile with Respimat SMI is favorable compared with MDIs and DPIs, with higher drug deposition to the lung and peripheral airways. The slow velocity and long spray duration of the Respimat SMI aerosol also aid patient coordination. Clinical equivalence has been demonstrated for maintenance treatment of chronic obstructive pulmonary disease using once-daily tiotropium between Respimat SMI (5 µg) and HandiHaler DPI (18 µg). In comparative studies, patients preferred Respimat SMI to MDIs and DPIs; they reported that Respimat SMI was easy to use and felt the inhaled dose was delivered. The Respimat SMI, designed to generate a slow-moving and fine mist, is easy to use and effectively delivers drug treatment to the lungs. The patient-centered design of Respimat SMI improved patient satisfaction, and may help to promote long-term adherence and improve clinical outcomes with asthma and chronic obstructive pulmonary disease.
Collapse
|
5
|
Mansfield L, Bernstein JA. Tiotropium in asthma: From bench to bedside. Respir Med 2019; 154:47-55. [PMID: 31212121 DOI: 10.1016/j.rmed.2019.06.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 05/21/2019] [Accepted: 06/10/2019] [Indexed: 10/26/2022]
Abstract
OBJECTIVE Tiotropium is a long-acting muscarinic antagonist approved for maintenance treatment of asthma in children, adolescents, and adults in the United States, and recommended as add-on treatment for uncontrolled asthma despite treatment with inhaled corticosteroids and/or long-acting beta-2 agonists. This review traces the journey of tiotropium from its historical origins through early preclinical testing to human clinical trials and real-life studies. DATA SOURCES A search was performed in PubMed using search terms 'tiotropium' and 'asthma.' Relevant references cited in those articles were reviewed. STUDY SELECTIONS English language articles published from December 2008-December 2018 were screened. Articles evaluating the efficacy, cost-effectiveness, real-life evidence, and steroid-sparing effect of tiotropium with inadequately controlled asthma were included. RESULTS Anticholinergics have a long history of use in the treatment of obstructive airway diseases. Evidence indicates that tiotropium's mechanism of action consists of bronchodilation and diminished mucus secretion, with preclinical evidence suggesting an anti-inflammatory effect as well. Phase 2 and 3 clinical trials have demonstrated that tiotropium is efficacious and safe, resulting in significant improvements in lung function in adults, adolescents, and children across asthma severities. Emerging evidence suggests that add-on tiotropium might potentially enable reductions in inhaled corticosteroid dose in patients with uncontrolled asthma. Further, tiotropium is a cost-effective treatment option that is also effective in the clinical practice setting. CONCLUSIONS An increasing body of evidence indicates that tiotropium can play a significant role in the treatment of patients with uncontrolled asthma.
Collapse
Affiliation(s)
- Lyndon Mansfield
- Department of Pediatrics, Paul L. Foster School of Medicine, El Paso, TX, USA
| | - Jonathan A Bernstein
- Department of Clinical Medicine, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
| |
Collapse
|
6
|
Abstract
Appropriate selection and correct use of inhalation devices is an integral component in the management of asthma and chronic obstructive pulmonary disease (COPD). It is well known that there are many challenges with the use of inhalers, and no one device suits all patients. Challenges can range from difficulties related to lung disease severity and pulmonary function to physical considerations, including manual dexterity and comorbidities such as arthritis. In terms of device selection and adherence, patient engagement and satisfaction are also important factors to consider. Furthermore, problems with inhaler use can be most evident in children and older patients. Here, we discuss aspects for consideration with commonly used devices, including nebulizers, pressurized metered-dose inhalers, dry powder inhalers, and the soft mist inhaler. As each inhaler offers varying technical properties, a tailored and personalized approach to the selection of the most appropriate device for the patient is highly recommended in order to increase the likelihood of achieving improved disease outcomes and enhance persistence with device adherence. Importantly, education and support is crucial, not only to enable patients to recognize the need for optimal disease management, but also to help them develop good inhaler technique. In addition, health care professionals should also aim to increase their knowledge of the devices they prescribe, and develop systems to ensure that they offer comprehensive support to patients in clinical practice. Considering these aspects, this review discusses potential strategies to help address the challenges of inhaler use in asthma and COPD.
Collapse
Affiliation(s)
- Omar S Usmani
- National Heart and Lung Institute (NHLI), Imperial College London and Royal Brompton Hospital, Airways Disease Section, London, UK,
| |
Collapse
|
7
|
Buhl R, Hamelmann E. Future perspectives of anticholinergics for the treatment of asthma in adults and children. Ther Clin Risk Manag 2019; 15:473-485. [PMID: 30936709 PMCID: PMC6422409 DOI: 10.2147/tcrm.s180890] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Despite major advances in therapeutic interventions and the availability of detailed treatment guidelines, a high proportion of patients with symptomatic asthma remain uncontrolled. Asthma management is largely guided by the Global Initiative for Asthma (GINA) strategy and is based on a backbone of inhaled corticosteroid (ICS) therapy with the use of additional therapies to achieve disease control. Inhaled long-acting bronchodilators alone and in combination are the preferred add-on treatment options. Although long-acting muscarinic antagonists (LAMAs) are a relatively recent addition to disease management recommendations for asthma, tiotropium has been extensively studied in a large clinical trial program. In Europe and the United States, tiotropium is approved for patients aged ≥6 years and uncontrolled on medium- to high-dose ICS/long-acting β2-agonists at GINA Steps 4 and 5 with a history of exacerbations. Evidence supports the efficacy of tiotropium Respimat® in adults in terms of lung function and asthma control, with a safety profile comparable with that of placebo across a range of asthma severities. Similarly, clinical trials in patients aged 1-17 years have shown improvements in lung function and trends toward improved asthma control. Furthermore, its efficacy makes tiotropium relatively easy to incorporate into routine clinical practice, irrespective of allergic status and without the need for patient phenotyping. Tiotropium is a cost-effective treatment that may offer an important alternative to other, more expensive add-on therapies. This review discusses the potential future position of LAMAs in clinical practice by considering the continuously evolving evidence. Prominence is given to tiotropium, the only LAMA supported by a structured clinical trial program in asthma to date, while also considering other recommended treatment options for patients with uncontrolled asthma. The importance of effective patient/caregiver-clinician communication and shared decision-making in enhancing treatment adherence is also highlighted.
Collapse
Affiliation(s)
- Roland Buhl
- Pulmonary Department, Johannes Gutenberg University Hospital Mainz, Mainz, Germany,
| | - Eckard Hamelmann
- Children's Center Bethel, Evangelic Hospital Bethel, Department of Pediatrics, Bielefeld, Germany
- University Children's Hospital, Allergy Center Ruhr, Ruhr University Bochum, Bochum, Germany
| |
Collapse
|
8
|
Goldstein S. Clinical efficacy and safety of anticholinergic therapies in pediatric patients. Ther Clin Risk Manag 2019; 15:437-449. [PMID: 30936706 PMCID: PMC6422407 DOI: 10.2147/tcrm.s161362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
The burden of uncontrolled asthma in children and adolescents is high. Treatment options for pediatric patients (aged under 18 years) with asthma are largely influenced by the Global Initiative for Asthma recommendations. Algorithms for adolescents (12-18 years) and adults are identical, but recommendations for children aged under 6 years and 6-11 years differ. Although the goals of treatment for pediatric patients with asthma are similar to those for adults, relatively few new therapies have been approved for this patient population within the last decade. Designing clinical trials involving children presents several challenges, notably that children are often less able to perform lung function tests, and traditional endpoints used in clinical trials with adults, such as forced expiratory volume in 1 second, asthma exacerbations and questionnaires, have limitations associated with their use in children. There are also ethical considerations related to the performance of longer placebo-controlled exacerbation trials. This review considers additional clinical endpoints to those traditionally reported, including forced expiratory flow at 25%-75% of forced vital capacity, which may help shed light on which treatments are most effective for use in pediatric patients with asthma. The pros and cons of specific and potentially clinically relevant endpoints are considered, along with device considerations and patient preferences that may enhance adherence and quality of life. Recent advances in the management of children and adolescents, including the US Food and Drug Administration and European Medicines Agency approval of tiotropium in patients with asthma aged 6 years and over, are also discussed.
Collapse
Affiliation(s)
- Stanley Goldstein
- Allergy and Asthma Care of Long Island, Rockville Centre, New York, NY, USA,
| |
Collapse
|
9
|
Oliveira MVCD, Pizzichini E, da Costa CH, Fritscher CC, Vianna EO, Teixeira PJZ, Stirbulov R, Rabahi MF, Pinho NCD. Evaluation of the preference, satisfaction and correct use of Breezhaler ® and Respimat ® inhalers in patients with chronic obstructive pulmonary disease - INHALATOR study. Respir Med 2018; 144:61-67. [PMID: 30366585 DOI: 10.1016/j.rmed.2018.10.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Revised: 10/02/2018] [Accepted: 10/06/2018] [Indexed: 11/24/2022]
Abstract
The INHALATOR study was a randomized, multicentre, open label, two-period of 7 days each, crossover study, with 7 days of washout in-between, aiming to evaluate the correct use, satisfaction and preference between Breezhaler® and Respimat® devices in patients under daily use of open Spiriva® or open Onbrize®, as monotherapy for treatment of mild or moderate COPD. Patients aged ≥40 years with a smoking history of at least 10 pack-year were included in the study. Primary endpoint was the rate of correct use of each device at the first day of treatment after reading the drug leaflet information and was evaluated under the supervision of a trained evaluator. At the end of each treatment phase, the inhaler use was re-evaluated and a satisfaction questionnaire was completed. The patients' preference for the inhaler devices was assessed at the end of the study. After exclusions due to screening failures, 140 patients were randomized: 136 received at least one dose of Breezhaler® and 135 of Respimat®. At treatment start, the rate of correct inhaler use was 40.4% (95%CI: 32.2%-48.7%) for Breezhaler® and 36.3% (95%CI: 28.2%-44.4%) for Respimat® (p = 0.451). After 7 days, the rates were 68.9% (95%CI: 61.1%-76.7%) and 60.4% (95%CI: 52.2%-68.7%), respectively (p = 0.077). According to the Feeling of Satisfaction with Inhaler Questionnaire - FSI 10 patients were more satisfied using Breezhaler® than Respimat® and 57.1% preferred using Breezhaler® (p = 0.001) while 30.1% preferred Respimat® (p < 0.001).
Collapse
Affiliation(s)
- Maria Vera Cruz de Oliveira
- Hospital do Servidor Público Estadual de São Paulo, Rua Pedro de Toledo, 1800 Bl F. 3° Andar, São Paulo/SP, 04039-901, Brazil
| | - Emilio Pizzichini
- NUPAIVA, Hospital Universitário, UFSC, Campos Universitário S/N, Trindade, Florianópolis /SC, 88040-970, Brazil
| | - Claudia Henrique da Costa
- UERJ, Policlínica Piquet Carneiro, Av. Marechal Rondon 381, São Francisco Xavier, Rio de Janeiro / RJ, 20950-003, Brazil
| | - Carlos Cezar Fritscher
- Hospital São Lucas da PUCRS, Av Ipiranga 6690, 4° andar, Porto Alegre / RS, 90610-000, Brazil
| | - Elcio Oliveira Vianna
- Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto, USP, Av. Bandeirantes 3900, CEP 14048-900, Ribeirão Preto, SP, Brazil
| | - Paulo José Zimermann Teixeira
- Irmandade da Santa Casa de Misericórdia de Porto Alegre-UFCSPA, Rua Prof. Annes Dias, 295, Pavilhão Pereira Filho, 1° andar, Porto Alegre / RS, 90020-090, Brazil
| | - Roberto Stirbulov
- Centro de Pesquisa Clínica em Pneumologia da Irmandade Santa Casa de Misericórdia de São Paulo, Rua Dr. Cesário Motta Jr. 112, Vila Buarque, São Paulo / SP, Brazil
| | - Marcelo Fouad Rabahi
- CLARE, Clínica de Pneumologia SS, Av. B 483, Setor Oeste, Goiânia / GO, 74110-030, Brazil
| | - Nadine Cordeiro de Pinho
- Novartis Biociências S.A. Brasil, Av. Prof. Vicente Rao, 90, Santo Amaro, São Paulo / SP, 04636-000, Brazil.
| |
Collapse
|
10
|
Hira D, Koide H, Nakamura S, Okada T, Ishizeki K, Yamaguchi M, Koshiyama S, Oguma T, Ito K, Funayama S, Komase Y, Morita SY, Nishiguchi K, Nakano Y, Terada T. Assessment of inhalation flow patterns of soft mist inhaler co-prescribed with dry powder inhaler using inspiratory flow meter for multi inhalation devices. PLoS One 2018; 13:e0193082. [PMID: 29462195 PMCID: PMC5819805 DOI: 10.1371/journal.pone.0193082] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Accepted: 01/22/2018] [Indexed: 11/19/2022] Open
Abstract
The patients’ inhalation flow pattern is one of the significant determinants for clinical performance of inhalation therapy. However, the development of inhalation flow meters for various inhalation devices has been unable to keep up with the increasing number of newly launched inhalation devices. In the present study, we developed simple attachment orifices for the inhalation flow pattern monitoring system, which are suitable for all commercial inhalers, and investigated the efficacy of the system on the clinical inhalation instruction for patients co-prescribed dry powder inhaler (DPI) and soft mist inhaler (SMI). First, we constructed simple attachment orifices that were adjusted for 13 commercial inhalers, and examined the correlation between orifice and inhalation device. Second, the inhalation flow patterns (peak inspiratory flow rate, PIFR; inhalation duration time, DT) of patients prescribed a combination of DPI and SMI were monitored before and after inhalation instruction. The inhalation resistance of commercial inhalers are listed in the following order; Twincaps® > Handihaler® > Swinghaler® = Clickhaler® > Twisthaler® > Turbuhaler® > Jenuair® > Diskus® = Ellipta® > Diskhaler® > Breezhaler® > Respimat® = pMDI. The pressure drop via orifice was significantly correlated with that via the commercial inhaler. For the confirmation, all participants achieved the DPI criterion of PIFR. On the other hand, 4 participants (6 clinical visits) of 10 experimented participants could not achieve the essential criterion of DT (> 1.5 sec) for SMI, but all participants improved their duration time after inhalation instruction by pharmacists (P<0.05). In the present study, we successfully developed simple attachment orifice suitable for 13 commercial inhalation devices. These data suggested that our simple attachment orifices for the inhalation flow pattern monitoring system can detect patients with inadequate inhalation patterns via SMI.
Collapse
Affiliation(s)
- Daiki Hira
- Department of Pharmacy, Shiga University of Medical Science Hospital, Otsu, Shiga, Japan
| | - Hiroyoshi Koide
- Department of Clinical Pharmacy, Faculty of Pharmaceutical Sciences, Kyoto Pharmaceutical University, Kyoto, Kyoto, Japan
| | | | - Toyoko Okada
- Hitachi Automotive Systems, Ltd., Isesaki, Gunma, Japan
| | | | - Masafumi Yamaguchi
- Department of Medicine, Division of Respiratory Medicine, Shiga University of Medical Science, Otsu, Shiga, Japan
| | | | | | - Kayoko Ito
- Oral Rehabilitation, Niigata University Medical and Dental Hospital, Niigata, Niigata, Japan
| | - Saori Funayama
- Oral Rehabilitation, Niigata University Medical and Dental Hospital, Niigata, Niigata, Japan
| | - Yuko Komase
- Department of Respiratory Internal Medicine, St. Marianna University, School of Medicine, Yokohama-City Seibu Hospital, Yokohama, Kanagawa, Japan
| | - Shin-ya Morita
- Department of Pharmacy, Shiga University of Medical Science Hospital, Otsu, Shiga, Japan
| | - Kohshi Nishiguchi
- Department of Clinical Pharmacy, Faculty of Pharmaceutical Sciences, Kyoto Pharmaceutical University, Kyoto, Kyoto, Japan
| | - Yasutaka Nakano
- Department of Medicine, Division of Respiratory Medicine, Shiga University of Medical Science, Otsu, Shiga, Japan
| | - Tomohiro Terada
- Department of Pharmacy, Shiga University of Medical Science Hospital, Otsu, Shiga, Japan
- * E-mail:
| |
Collapse
|
11
|
Hawken N, Torvinen S, Neine ME, Amri I, Toumi M, Aballéa S, Plich A, Roche N. Patient preferences for dry powder inhaler attributes in asthma and chronic obstructive pulmonary disease in France: a discrete choice experiment. BMC Pulm Med 2017; 17:99. [PMID: 28683805 PMCID: PMC5501405 DOI: 10.1186/s12890-017-0439-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Accepted: 06/19/2017] [Indexed: 11/28/2022] Open
Abstract
Background Dry powder inhalers (DPIs) are often used in asthma and chronic obstructive pulmonary disease (COPD) therapies. Using the discrete choice experiment (DCE) methodology, this study conducted in France was designed to assess patients’ preferences for different attributes of DPIs. Methods Attributes of DPIs were defined based on a literature review, patient focus group discussions and interviews with healthcare professionals (qualitative phase of the study). An online survey was then conducted among French patients with asthma or COPD to elicit patient preferences and willingness to pay (WTP) for these attributes using the DCE methodology (quantitative phase). A fractional factorial design including three blocks of 12 choice sets was created. Each choice set comprised three alternatives: two fictitious inhalers and the patient’s current inhaler. Marginal utilities were estimated using a ranked ordered logit model. Interactions between attributes and disease (asthma or COPD) were tested. Results Six DPI attributes were defined based on the qualitative phase: ease of use/fool-proof priming; accurate and easy-to-read dose counter; dose confirmation; hygiene of the mouthpiece; flexibility of the device handling; ability to use the inhaler with breathing difficulties. Overall, 201 patients with asthma and 93 with COPD were included in the online survey. Patients with asthma placed most value on an inhaler that requires one step for dose preparation (WTP €4.83 [95% CI: €3.77–€5.90], relative to an inhaler requiring four steps) and one that could be used during episodes of breathing difficulties (WTP €4.49 [95% CI: €2.95–€6.02]). Patients with COPD placed most value on an inhaler that could be used during episodes of breathing difficulties (WTP €7.70 [95% CI: €5.65–€9.76]) and on the accuracy of the dose counter (WTP €5.87 [95% CI: €3.98–€ 7.77]). Conclusion This study suggests that asthma and COPD patients would be willing to change their inhaler if they were offered the option of a new inhaler with improved characteristics and they place a high value on an inhaler with ease of use during breathing difficulty episodes. Electronic supplementary material The online version of this article (doi:10.1186/s12890-017-0439-x) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Natalia Hawken
- Creativ-Ceutical, Westblaak 92, 3012 KM, Rotterdam, The Netherlands.
| | - Saku Torvinen
- Teva Pharmaceuticals Europe BV, Amsterdam, The Netherlands
| | | | - Ikbel Amri
- Creativ-Ceutical, Rue du lac Huron Résidence Farah, Bloc B, 1053, Les Berges du Lac, Tunisia
| | - Mondher Toumi
- Creativ-Ceutical SARL, 215, rue du Faubourg St-Honoré, 75008, Paris, France
| | - Samuel Aballéa
- Creativ-Ceutical SARL, 215, rue du Faubourg St-Honoré, 75008, Paris, France
| | - Adam Plich
- Teva Pharmaceuticals Europe BV, Amsterdam, The Netherlands
| | - Nicolas Roche
- Respiratory and Intensive Care Medicine, Cochin Hospital Group, AP-HP, University Paris Descartes, Paris, France
| |
Collapse
|
12
|
Halpin DM, Kaplan AG, Russell RK. Why choose tiotropium for my patient? A comprehensive review of actions and outcomes versus other bronchodilators. Respir Med 2017; 128:28-41. [PMID: 28610667 DOI: 10.1016/j.rmed.2017.04.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Revised: 04/12/2017] [Accepted: 04/13/2017] [Indexed: 12/12/2022]
Abstract
PURPOSE Chronic obstructive pulmonary disease (COPD) and asthma are leading causes of morbidity and mortality. This narrative review provides an appraisal of the pharmacological and clinical characteristics of tiotropium in COPD and asthma, and examines how these compare with other long-acting bronchodilators. The evidence base is placed into context by relating it to factors affecting clinicians' choice of therapy. MAIN FINDINGS Desirable attributes of a long-acting muscarinic antagonist (LAMA) maintenance therapy include effective pharmacological bronchodilation, improved lung function, exacerbation efficacy, and positive effects on symptom control, exercise capacity and quality of life across a broad patient population. Tolerability and convenience of use are also important for patient well-being and treatment adherence. Tiotropium shows higher affinity for muscarinic receptors than ipratropium, and prolonged binding to the M3 receptor compared with other LAMAs. In COPD, tiotropium has demonstrated improved lung function and exacerbation prevention compared with placebo or long-acting β2-agonists, similar exacerbation efficacy to other LAMAs, and enhanced symptom control and health status versus placebo. UniTinA-asthma® showed the benefits of add-on tiotropium in patients with uncontrolled mild to moderate and severe asthma. Tiotropium is well tolerated, with an incidence of adverse events similar to placebo, except for known infrequent side effects of anticholinergics. Tiotropium HandiHaler® and Respimat® augment inhaler choice in COPD. PRINCIPAL CONCLUSIONS With over 10 years' prescribing history and 50 million patient-years of use, tiotropium has the benefit of a more extensive clinical evidence base than other long-acting bronchodilators, with demonstrated efficacy and safety in COPD and symptomatic asthma.
Collapse
Affiliation(s)
- David M Halpin
- Royal Devon & Exeter Hospital, Barrack Road, Exeter, EX2 5DW, United Kingdom.
| | - Alan G Kaplan
- Department of Family and Community Medicine, University of Toronto, 500 University Avenue, Toronto, Ontario, ON M5G 1V7, Canada.
| | - Richard K Russell
- Nuffield Department of Medicine, University of Oxford, John Radcliffe Hospital, Headley Way, Headington, Oxford, OX3 9DS, United Kingdom.
| |
Collapse
|
13
|
Wachtel H, Kattenbeck S, Dunne S, Disse B. The Respimat® Development Story: Patient-Centered Innovation. Pulm Ther 2017. [DOI: 10.1007/s41030-017-0040-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
14
|
Cazzola M, Ora J, Puxeddu E, Rogliani P. Indacaterol/Glycopyrronium Combination for COPD. Pulm Ther 2017. [DOI: 10.1007/s41030-016-0024-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
|
15
|
Dahl R, Kaplan A. A systematic review of comparative studies of tiotropium Respimat® and tiotropium HandiHaler® in patients with chronic obstructive pulmonary disease: does inhaler choice matter? BMC Pulm Med 2016; 16:135. [PMID: 27724909 PMCID: PMC5057252 DOI: 10.1186/s12890-016-0291-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Accepted: 08/18/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND In many countries worldwide, the long-acting anticholinergic drug tiotropium is available as a dry powder formulation delivered by means of the HandiHaler® inhalation device and as an aqueous solution delivered via the Respimat® Soft Mist™ Inhaler. Tiotropium HandiHaler® is a single-dose, dry powder, breath-actuated inhaler that provides delivered doses and lung deposition of tiotropium that are, over a wide range, not influenced by the severity of chronic obstructive pulmonary disease (COPD). Tiotropium Respimat® is a propellant-free, multi-dose inhaler that delivers a metered dose of medication as a fine, slow-moving, long-lasting soft mist, independently of patient inspiratory effort. The high fine-particle fraction of droplets produced by the Respimat® inhaler optimizes the efficiency of drug delivery to the lungs. METHODS To help inform the choice of tiotropium inhaler for prescribers and patients, this systematic review summarizes the available pharmacokinetic, efficacy and safety data from comparative studies of tiotropium Respimat® and tiotropium HandiHaler® in COPD, focusing on the licensed once-daily doses of 5 and 18 μg, respectively. Data sources reviewed include publications and abstracts identified from database searches. RESULTS Published evidence from comparative studies suggests that tiotropium Respimat® 5 μg and tiotropium HandiHaler® 18 μg provide similar clinical outcomes in patients with COPD. CONCLUSIONS The findings indicate that physicians can base their decision about an inhaler for tiotropium on factors other than efficacy or safety. These could be patient preference for a particular inhaler, ease of use and the efficiency of drug delivery, with the aim of optimizing adherence and clinical outcomes with long-term tiotropium maintenance therapy.
Collapse
Affiliation(s)
- Ronald Dahl
- Odense University Hospital, Odense, Denmark.
| | - Alan Kaplan
- Family Physician Airways Group of Canada, Richmond Hill, ON, Canada
| |
Collapse
|
16
|
Jahedi L, Downie SR, Saini B, Chan HK, Bosnic-Anticevich S. Inhaler Technique in Asthma: How Does It Relate to Patients' Preferences and Attitudes Toward Their Inhalers? J Aerosol Med Pulm Drug Deliv 2016; 30:42-52. [PMID: 27676193 PMCID: PMC5278803 DOI: 10.1089/jamp.2016.1287] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Background: Correct inhaler technique can increase medication efficacy, reducing both dose and side effects. Patient preference for inhaler device has not been fully explored, and we hypothesized that if patients have a preference and can choose their inhaler, they might be more likely to use it correctly. Our aim was to determine the preferences, attitudes, and perceptions of patients with asthma toward their inhalers, and to evaluate whether any of these factors were related to inhalation technique. Methods: Twenty-five patients with asthma (mean age 43.1 years) participated. Qualitative semi-structured interviews and quantitative patient satisfaction and preference questionnaires (PASAPQ) were used to explore patients' preferences, attitudes, and perceptions about their inhalers. Objective inhalation technique assessment was performed. Data were triangulated to identify characteristics that could indicate a relationship between inhaler technique, satisfaction, preference, and decision making. Results: Themes from qualitative interviews were as follows: asthma inhalers and expectations; inhaler preference; characteristics of an ideal inhaler; perceived effectiveness of inhalers; and inhalers and patient decision making. PASAPQ scores indicated that all patients were at least “somewhat satisfied” with their inhalers, regardless of technique. Only 12% of inhalers were used correctly, despite pilot PASAPQ data suggesting that most patients were confident with their technique. The inhaler technique was unlikely to be related to satisfaction, perception of inhaler devices, or choice in device selection. Patients with correct inhaler technique were more aware of their asthma and expressed motivation to achieve optimal asthma control. Conclusions: The majority of the asthmatic patients did not use their inhaler(s) correctly, despite most having confidence in their technique. Patients attributed confidence in their inhaler technique to their belief that their inhaler was effective. Most patients had not been involved in decision making about which inhalation device to use. These findings highlight the lack of understanding of the important role of correct inhaler technique in asthma management.
Collapse
Affiliation(s)
- Lia Jahedi
- 1 Woolcock Institute of Medical Research , Glebe, Australia .,2 Faculty of Pharmacy, University of Sydney , Sydney, Australia
| | - Sue R Downie
- 1 Woolcock Institute of Medical Research , Glebe, Australia
| | - Bandana Saini
- 2 Faculty of Pharmacy, University of Sydney , Sydney, Australia .,3 The NHMRC Centre for Integrated Research and Understanding of Sleep (CIRUS) , Glebe, Australia
| | - Hak-Kim Chan
- 2 Faculty of Pharmacy, University of Sydney , Sydney, Australia .,4 Advanced Drug Delivery Group, Faculty of Pharmacy, University of Sydney , Sydney, Australia
| | - Sinthia Bosnic-Anticevich
- 1 Woolcock Institute of Medical Research , Glebe, Australia .,5 Sydney Medical School, University of Sydney , Sydney, Australia .,6 Sydney Local Health District , Sydney, Australia
| |
Collapse
|
17
|
Dekhuijzen PNR, Lavorini F, Usmani OS. Patients' perspectives and preferences in the choice of inhalers: the case for Respimat(®) or HandiHaler(®). Patient Prefer Adherence 2016; 10:1561-72. [PMID: 27574405 PMCID: PMC4993394 DOI: 10.2147/ppa.s82857] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Poor inhaler technique hampers the efficacy of drug therapy in asthma and chronic obstructive pulmonary disease. Not only does this affect individual patient care, but it also impacts on the wider health care economics associated with these conditions. Treatment guidelines recommend a systematic approach to drug class selection; however, standardization of inhaler selection is currently difficult owing to the complexity of the interaction between the inhaler device and the patient. Specifically, individual patient preference can influence how successful a treatment is overall. This article reviews inhaler devices from the patient perspective, with a particular focus on the dry powder inhaler HandiHaler(®) and Respimat(®) Soft Mist™ Inhaler. It discusses factors that influence device preference and treatment compliance and reviews tools that can aid health care professionals to better match inhaler devices to individual patients' needs.
Collapse
Affiliation(s)
| | - Federico Lavorini
- Department of Experimental and Clinical Medicine, Careggi University Hospital, Florence, Italy
| | - Omar S Usmani
- National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, UK
| |
Collapse
|
18
|
Abstract
Chronic obstructive pulmonary disease (COPD) is a major cause of death and disability worldwide. Inhaled bronchodilators are the mainstay of COPD pharmacological treatment. Long-acting muscarinic antagonists (LAMAs) are a major class of inhaled bronchodilators. Some LAMA/device systems with different characteristics and dosing schedules are currently approved for maintenance therapy of COPD and a range of other products are being developed. They improve lung function and patient-reported outcomes and reduce acute bronchial exacerbations with good safety. LAMAs are used either alone or associated with long-acting β₂-agonists, eventually in fixed dose combinations. Long-acting β₂-agonist/LAMA combinations assure additional benefits over the individual components alone. The reader will obtain a view of the safety and efficacy of the different LAMA/device systems in COPD patients.
Collapse
Affiliation(s)
- Andrea S Melani
- Dipartimento Vasi, Cuore e Torace, Fisiopatologia e Riabilitazione Respiratoria, Policlinico Le Scotte, Azienda Ospedaliera Universitaria Senese, Viale Bracci Siena, Italy
| |
Collapse
|
19
|
Miravitlles M, Montero-Caballero J, Richard F, Santos S, Garcia-Rivero JL, Ortega F, Ribera X. A cross-sectional study to assess inhalation device handling and patient satisfaction in COPD. Int J Chron Obstruct Pulmon Dis 2016; 11:407-15. [PMID: 27013871 PMCID: PMC4777273 DOI: 10.2147/copd.s91118] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Delivery of inhaled medications via an inhaler device underpins the effectiveness of treatment for patients with chronic obstructive pulmonary disease (COPD). Correct inhaler technique among patients is also a predictor of achieving treatment compliance and adherence. Reporting of patient satisfaction with inhalers is therefore gaining increasing attention and is now recognized as an important patient-reported outcome in clinical trials involving patients with COPD or asthma. In this cross-sectional study, we use the validated Patient Satisfaction and Preference Questionnaire (PASAPQ) to assess the handling and satisfaction for Respimat(®) Soft Mist™ Inhaler (SMI) compared with the Breezhaler(®) dry powder inhaler (DPI) among patients with COPD in Spain. Patients were already assigned to therapy with either SPIRIVA(®) (tiotropium) Respimat(®) or with Hirobriz(®)/Onbrez(®)/Oslif(®) (indacaterol) Breezhaler(®) for at least 3 but not more than 6 months before completing the PASAPQ at a single visit to the study site. The primary endpoint of the trial was the mean total PASAPQ score. Secondary endpoints were the performance score domain of the PASAPQ, the convenience score domain of the PASAPQ, and the overall satisfaction score of the PASAPQ. For the primary endpoint, the mean PASAPQ total score in the Respimat(®) and Breezhaler(®) groups was 80.7 and 79.9, respectively (difference of 0.8, 95% confidence interval [CI] -2.9 to 4.5; P=0.67). The mean total performance scores were 82.5 and 78.2 (difference of 4.3, 95% CI -0.3 to 8.9; P=0.06), and the mean total convenience scores were 78.6 and 81.9 (difference of -3.3, 95% CI -7.0 to 0.4; P=0.08) for the Respimat(®) and Breezhaler(®) groups, respectively. Patients gave the Respimat(®) SMI and the Breezhaler(®) DPI overall satisfaction PASAPQ scores of 6.0 and 5.9, respectively, which shows that patients were satisfied with these inhalers.
Collapse
Affiliation(s)
- Marc Miravitlles
- Pneumology Department, Hospital Universitari Vall d'Hebron, Ciber de Enfermedades Respiratorias (CIBERES), Barcelona, Spain
| | | | - Frank Richard
- Boehringer Ingelheim Pharma GmbH & Co KG, Ingelheim, Germany
| | - Salud Santos
- Pulmonology Department, Hospital Universitari de Bellvitge, IDIBELL, Universitat de Barcelona, Ciber de Enfermedades Respiratorias (CIBERES), Barcelona, Spain
| | | | - Francisco Ortega
- Pneumology Department, Hospital Virgen del Rocío, Sevilla, Spain
| | - Xavier Ribera
- Boehringer Ingelheim Pharma GmbH & Co KG, Barcelona, Spain
| |
Collapse
|
20
|
Preference, satisfaction and critical errors with Genuair and Breezhaler inhalers in patients with COPD: a randomised, cross-over, multicentre study. NPJ Prim Care Respir Med 2015; 25:15018. [PMID: 25927321 PMCID: PMC4415437 DOI: 10.1038/npjpcrm.2015.18] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2014] [Revised: 12/22/2014] [Accepted: 02/03/2015] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND The specific attributes of inhaler devices can influence patient use, satisfaction and treatment compliance, and may ultimately impact on clinical outcomes in patients with chronic obstructive pulmonary disease (COPD). AIMS To assess patient preference, satisfaction and critical inhaler technique errors with Genuair (a multidose inhaler) and Breezhaler (a single-dose inhaler) after 2 weeks of daily use. METHODS Patients with COPD and moderate to severe airflow obstruction were randomised in a cross-over, open-label, multicentre study to consecutive once-daily inhalations of placebo via Genuair and Breezhaler, in addition to current COPD medication. The primary end point was the proportion of patients who preferred Genuair versus Breezhaler after 2 weeks (Patient Satisfaction and Preference Questionnaire). Other end points included overall satisfaction and correct use of the inhalers after 2 weeks, and willingness to continue with each device. RESULTS Of the 128 patients enrolled, 127 were included in the safety population (male n=91; mean age 67.6 years). Of the 110 of the 123 patients in the intent-to-treat population who indicated an inhaler preference, statistically significantly more patients preferred Genuair than Breezhaler (72.7 vs. 27.3%; P<0.001). Mean overall satisfaction scores were also greater for Genuair than for Breezhaler (5.9 vs. 5.3, respectively; P<0.001). After 2 weeks, there was no statistically significant difference in the number of patients who made ⩾1 critical inhaler technique error with Breezhaler than with Genuair (7.3 vs. 3.3%, respectively). CONCLUSIONS Patient overall preference and satisfaction was significantly higher with Genuair compared with Breezhaler. The proportion of patients making critical inhaler technique errors was low with Genuair and Breezhaler.
Collapse
|
21
|
Bereza BG, Troelsgaard Nielsen A, Valgardsson S, Hemels MEH, Einarson TR. Patient preferences in severe COPD and asthma: a comprehensive literature review. Int J Chron Obstruct Pulmon Dis 2015; 10:739-44. [PMID: 25914530 PMCID: PMC4399696 DOI: 10.2147/copd.s82179] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Background Management of chronic incurable diseases such as chronic obstructive pulmonary disease (COPD) and asthma is difficult. Incorporation of patient preferences is widely encouraged. Purpose To summarize original research articles determining patient preference in moderate-to-severe disease. Methods Acceptable articles consisted of original research determining preferences for any aspect of care in patients with COPD/asthma. The target population included those with severe disease; however, articles were accepted if they separated outcomes by severity or if the majority had at least moderate-to-severe disease. We also accepted simulation research based on scenarios describing situations involving moderate-to-severe disease that elicited preferences. Two reviewers searched Medline and Embase for articles published from the date of inception of the databases until the end of November 2014, with differences resolved through consensus discussion. Data were tabulated and analyzed descriptively. Results About 478 articles identified, 448 were rejected and 30 analyzed. There were 25 on COPD and five on asthma. Themes identified as most important in COPD were symptom relief (dyspnea/breathlessness), a positive patient–physician relationship, quality-of-life impairments, and information availability. Patients strongly preferred sponsors’ inhalers. At end-of-life, 69% preferred receiving CPR, 70% wanted noninvasive, and 58% invasive mechanical intervention. While patients with asthma preferred treatments that increased symptom-free days, they were willing to trade days without symptoms for a reduction in adverse events and greater convenience. Asthma patients were willing to pay for waking up once and not needing their inhaler over waking up once overnight and needing their inhaler. Conclusion Few studies have examined patient preference in these diseases. More research is needed to fill in knowledge gaps.
Collapse
Affiliation(s)
- Basil G Bereza
- Leslie Dan Faculty of Pharmacy, University of Toronto, ON, Canada
| | | | | | | | | |
Collapse
|
22
|
Rajan SK, Gogtay JA. Ease-of-use, preference, confidence, and satisfaction with Revolizer(®), a novel dry powder inhaler, in an Indian population. Lung India 2014; 31:366-74. [PMID: 25378845 PMCID: PMC4220319 DOI: 10.4103/0970-2113.142122] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
CONTEXT While prescribing an inhaler device, it is important to take into account the usability, preference, confidence, and satisfaction of the patients. AIMS The present study assessed these parameters with Revolizer(®), a novel dry powder inhaler (DPI), in patients with obstructive airway diseases and in device-naïve healthy participants. SETTINGS AND DESIGN In this open-label, prospective, multicentre study with 100 participants [n = 50 healthy participants, n = 45 mild asthma patients, and n = 5 mild chronic obstructive pulmonary disease (COPD) patients], all participants were instructed and trained on the use of Revolizer and then the participants subsequently demonstrated the inhalation technique at two visits. MATERIALS AND METHODS The average time required to execute three correct consecutive attempts and the number of errors (including critical errors) were recorded. Participants were asked about the ease of use, preference, confidence, and satisfaction by means of a questionnaire at each visit. RESULTS The average time required by the participants to achieve three correct consecutive attempts at visit 1 was 3.75 ± 2.10 min, which significantly reduced at visit 2 (3.07 ± 1.32 min, P < 0.01). The number of errors decreased from visit 1 to visit 2. More than 85% participants found the Revolizer easy to use, and it was preferred by more than 75% participants. Revolizer scored high on the confidence and satisfaction of all participants at both visits. CONCLUSIONS Revolizer is an easy-to-use and a preferred device in patients with mild asthma and COPD, as well as in healthy participants with no previous experience of using inhalation devices. The participants felt confident and satisfied using the Revolizer.
Collapse
Affiliation(s)
- Sujeet K Rajan
- Department of Chest Medicine, Bhatia Hospital and Bombay Hospital and Medical Research Centre, Mumbai, Maharashtra, India
| | - Jaideep A Gogtay
- Chief Medical Officer, Department of Medical Services, Cipla Limited, Mumbai, Maharashtra, India
| |
Collapse
|
23
|
Chan JGY, Wong J, Zhou QT, Leung SSY, Chan HK. Advances in device and formulation technologies for pulmonary drug delivery. AAPS PharmSciTech 2014; 15:882-97. [PMID: 24728868 DOI: 10.1208/s12249-014-0114-y] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2014] [Accepted: 03/13/2014] [Indexed: 12/31/2022] Open
Abstract
Inhaled pharmaceuticals are formulated and delivered differently according to the therapeutic indication. However, specific device-formulation coupling is often fickle, and new medications or indications also demand new strategies. The discontinuation of chlorofluorocarbon propellants has seen replacement of older metered dose inhalers with dry powder inhaler formulations. High-dose dry powder inhalers are increasingly seen as an alternative dosage form for nebulised medications. In other cases, new medications have completely bypassed conventional inhalers and been formulated for use with unique inhalers such as the Staccato® device. Among these different devices, integration of software and electronic assistance has become a shared trend. This review covers recent device and formulation advances that are forming the current landscape of inhaled therapeutics.
Collapse
|
24
|
The clinical relevance of dry powder inhaler performance for drug delivery. Respir Med 2014; 108:1195-203. [PMID: 24929253 DOI: 10.1016/j.rmed.2014.05.009] [Citation(s) in RCA: 97] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2014] [Revised: 05/08/2014] [Accepted: 05/13/2014] [Indexed: 01/27/2023]
Abstract
BACKGROUND Although understanding of the scientific basis of aerosol therapy with dry powder inhalers (DPIs) has increased, some misconceptions still persist. These include the beliefs that high resistance inhalers are unsuitable for some patients, that extra fine (<1.0 μm) particles improve peripheral lung deposition and that inhalers with flow rate-independent fine particle fractions (FPFs) produce a more consistent delivered dose to the lungs. OBJECTIVES This article aims to clarify the complex inter-relationships between inhaler design and resistance, inspiratory flow rate (IFR), FPF, lung deposition and clinical outcomes, as a better understanding may result in a better choice of DPI for individual patients. METHODS The various factors that determine the delivery of drug particles into the lungs are reviewed. These include aerodynamic particle size distribution, the inspiratory manoeuvre, airway geometry and the three basic principles that determine the site and extent of deposition: inertial impaction, sedimentation and diffusion. DPIs are classed as either dependent or independent of inspiratory flow rate and vary in their internal resistance to inspiration. The effects of these characteristics on drug deposition in the airways are described using data from studies directly comparing currently available inhaler devices. RESULTS Clinical experience shows that most patients can use a high resistance DPI effectively, even during exacerbations. Particles in the aerodynamic size range from 1.5-5 μm are shown to be optimal, as particles <1.0 μm are very likely to be exhaled again while those >5 μm may impact on the oropharynx. For DPIs with a constant FPF at all flow rates, less of the delivered dose reaches the central and peripheral lung when the flow rate increases, risking under-dosing of the required medication. In contrast, flow rate-dependent inhalers increase their FPF output at higher flow rates, which compensates for the greater impaction on the upper airways as flow rate increases. CONCLUSIONS The technical characteristics of different inhalers and the delivery and deposition of the fine particle dose to the lungs may be important additional considerations to help the physician to select the most appropriate device for the individual patient to optimise their treatment.
Collapse
|
25
|
Panos RJ. Efficacy and safety of eco-friendly inhalers: focus on combination ipratropium bromide and albuterol in chronic obstructive pulmonary disease. Int J Chron Obstruct Pulmon Dis 2013; 8:221-30. [PMID: 23658481 PMCID: PMC3643287 DOI: 10.2147/copd.s31246] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Background Chronic obstructive pulmonary disease (COPD) is a major cause of morbidity and mortality and its treatment is critical to improve quality of life, reduce symptoms, and diminish the frequency of COPD exacerbations. Due to the harmful environmental effects of pressurized metered-dose inhalers (pMDIs) containing chlorofluorocarbons (CFCs), newer systems for delivering respiratory medications have been developed. Methods A search of the literature in the PubMed database was undertaken using the keywords “COPD,” “albuterol,” “ipratropium bromide,” and “Respimat® Soft Mist Inhaler™”; pertinent references within the identified citations were included. The environmental effect of CFC-pMDIs, the invention of the Respimat® Soft Mist Inhaler™ (SMI) (Boehringer Ingelheim, Ingelheim, Germany), and its use to deliver the combination of albuterol and ipratropium bromide for the treatment of COPD were reviewed. Results The adverse environmental effects of CFC-pMDIs stimulated the invention of novel delivery systems including the Respimat SMI. This review presents its development, internal mechanism, and use to deliver the combination of albuterol and ipratropium bromide. Conclusion CFC-pMDIs contributed to the depletion of the ozone layer and the surge in disorders caused by harmful ultraviolet B radiation. The banning of CFCs spurred the development of novel delivery systems for respiratory medications. The Respimat SMI is an innovative device that produces a vapor of inhalable droplets with reduced velocity and prolonged aerosol duration that enhance deposition within the lower airway and is associated with improved patient satisfaction. Clinical trials have demonstrated that the Respimat SMI can achieve effects equivalent to pMDIs but with lower medication doses. The long-term safety and efficacy remain to be determined. The Respimat SMI delivery device is a novel, efficient, and well-received system for the delivery of aerosolized albuterol and ipratropium bromide to patients with COPD; however, the presence of longer-acting, less frequently dosed respiratory medications provide patients and providers with other therapeutic options.
Collapse
Affiliation(s)
- Ralph J Panos
- Pulmonary, Critical Care, and Sleep Medicine Division, Cincinnati Veterans Affairs Medical Center, Cincinnati, OH 45220, USA.
| |
Collapse
|
26
|
Abrahams R, Moroni-Zentgraf P, Ramsdell J, Schmidt H, Joseph E, Karpel J. Safety and efficacy of the once-daily anticholinergic BEA2180 compared with tiotropium in patients with COPD. Respir Med 2013; 107:854-62. [PMID: 23490224 DOI: 10.1016/j.rmed.2013.02.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2012] [Revised: 02/04/2013] [Accepted: 02/11/2013] [Indexed: 11/30/2022]
Abstract
BACKGROUND To determine the safety and efficacy of BEA2180, an anticholinergic agent in patients with chronic obstructive pulmonary disease (COPD). METHODS Smokers or ex-smokers ≥40 years with COPD and a postbronchodilator forced expiratory volume in 1 s (FEV1) <80% predicted and FEV1/forced vital capacity ≤70% participated in this multinational, randomised, double-blind, parallel study. Patients received BEA2180 (50, 100 or 200 μg), tiotropium (5 μg) or placebo once daily via Respimat Soft Mist™. The primary endpoint was trough FEV1 after 24 weeks. Secondary endpoints included Transition Dyspnoea Index (TDI) focal score, St George's Respiratory Questionnaire (SGRQ) total score, exacerbations and adverse events. RESULTS Patients (n = 2080, 64.5% male) had a mean age of 64.2 years and a baseline FEV1 of 1.2 L. Trough FEV1 at 24 weeks with all BEA2180 doses (0.044-0.087 L) and tiotropium 5 μg (0.092 L) was significantly higher (p < 0.0001) than placebo (-0.034 L) and BEA2180 (200 μg) was noninferior to tiotropium. Mean TDI focal scores were higher with BEA2180 (1.43-1.48) or tiotropium (1.46) versus placebo (0.94; p ≤ 0.01 for all). Mean SGRQ total scores also improved with BEA2180 (40.1-40.7) or tiotropium (39.5) compared with placebo (43.0, p < 0.01 for all). COPD exacerbation rates were reduced for all active treatments, reaching statistical significance for BEA2180 (50 and 200 μg) (p < 0.05, for both). CONCLUSION All study doses of BEA2180 improved lung function, reduced symptoms and exacerbations, and improved health status in COPD; all treatments were well tolerated. Clinical trial identifier: NCT00528996.
Collapse
Affiliation(s)
- Roger Abrahams
- Morgantown Pulmonary Associates, Morgantown, 1265 Pineview Drive, Morgantown, WV 26505, USA
| | | | | | | | | | | |
Collapse
|
27
|
Dalby RN, Eicher J, Zierenberg B. Development of Respimat(®) Soft Mist™ Inhaler and its clinical utility in respiratory disorders. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2011; 4:145-55. [PMID: 22915941 PMCID: PMC3417885 DOI: 10.2147/mder.s7409] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
The Respimat(®) Soft Mist™ Inhaler (SMI) (Boehringer Ingelheim International GmbH, Ingelheim, Germany) was developed in response to the need for a pocket-sized device that can generate a single-breath, inhalable aerosol from a drug solution using a patient-independent, reproducible, and environmentally friendly energy supply. This paper describes the design and evolution of this innovative device from a laboratory concept model and the challenges that were overcome during its development and scaleup to mass production. A key technical breakthrough was the uniblock, a component combining filters and nozzles and made of silicon and glass, through which drug solution is forced using mechanical power. This allows two converging jets of solution to collide at a controlled angle, generating a fine aerosol of inhalable droplets. The mechanical energy comes from a spring which is tensioned by twisting the base of the device before use. Additional features of the Respimat(®) SMI include a dose indicator and a lockout mechanism to avoid the problems of tailing-off of dose size seen with pressurized metered dose inhalers. The Respimat(®) SMI aerosol cloud has a unique range of technical properties. The high fine particle fraction allied with the low velocity and long generation time of the aerosol translate into a higher fraction of the emitted dose being deposited in the lungs compared with aerosols from pressurized metered dose inhalers and dry powder inhalers. These advantages are realized in clinical trials in adults and children with obstructive lung diseases, which have shown that the efficacy and safety of a pressurized metered dose inhaler formulation of a combination bronchodilator can be matched by a Respimat(®) SMI formulation containing only one half or one quarter of the dose delivered by a pressurized metered dose inhaler. Patient satisfaction with the Respimat(®) SMI is high, and the long duration of the spray is of potential benefit to patients who have difficulty in coordinating inhalation with drug release.
Collapse
Affiliation(s)
- Richard N Dalby
- Department of Pharmaceutical Sciences, University of Maryland, Baltimore, MD, USA
| | | | | |
Collapse
|
28
|
Qamar N, Pappalardo AA, Arora VM, Press VG. Patient-centered care and its effect on outcomes in the treatment of asthma. Patient Relat Outcome Meas 2011; 2:81-109. [PMID: 22915970 PMCID: PMC3417925 DOI: 10.2147/prom.s12634] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2011] [Indexed: 11/23/2022] Open
Abstract
Patient-centered care may be pivotal in improving health outcomes for patients with asthma. In addition to increased attention in both research and clinical forums, recent legislation also highlights the importance of patient-centered outcomes research in the Patient Protection and Affordable Care Act. However, whether patient-centered care has been shown to improve outcomes for this population is unclear. To answer this question, we performed a systematic review of the literature that aimed to define current patient-focused management issues, characterize important patient-defined outcomes in asthma control, and identify current and emerging treatments related to patient outcomes and perspectives. We used a parallel search strategy via Medline(®), Cochrane Central Register of Controlled Trials, CINAHL(®) (Cumulative Index to Nursing and Allied Health Literature), and PsycINFO(®), complemented with a reference review of key articles that resulted in a total of 133 articles; 58 were interventions that evaluated the effect on patient-centered outcomes, and 75 were descriptive studies. The majority of intervention studies demonstrated improved patient outcomes (44; "positive" results); none showed true harm (0; "negative"); and the remainder were equivocal (14; "neutral"). Key themes emerged relating to patients' desires for asthma knowledge, preferences for tailored management plans, and simplification of treatment regimens. We also found discordance between physicians and patients regarding patients' needs, beliefs, and expectations about asthma. Although some studies show promise regarding the benefits of patient-focused care, these methods require additional study on feasibility and strategies for implementation in real world settings. Further, it is imperative that future studies must be, themselves, patient-centered (eg, pragmatic comparative effectiveness studies) and applicable to a variety of patient populations and settings. Despite the need for further research, enough evidence exists that supports incorporating a patient-centered approach to asthma management, in order to achieve improved outcomes and patient health.
Collapse
Affiliation(s)
- Nashmia Qamar
- Pediatric Residency Program, University of Chicago Medical Center, Chicago, IL, USA
| | - Andrea A Pappalardo
- Internal Medicine-Pediatric Residency Program, University of Chicago Medical Center, Chicago, IL, USA
| | - Vineet M Arora
- Section of General Internal Medicine, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA
| | - Valerie G Press
- Section of Hospital Medicine, Department of Medicine, University of Chicago Medical Center, Chicago, IL, USA
| |
Collapse
|
29
|
Rau-Berger H, Mitfessel H, Glaab T. Tiotropium Respimat® improves physical functioning in chronic obstructive pulmonary disease. Int J Chron Obstruct Pulmon Dis 2010; 5:367-73. [PMID: 21103403 PMCID: PMC2981151 DOI: 10.2147/copd.s14082] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2010] [Indexed: 11/23/2022] Open
Abstract
AIM This observational study with tiotropium Respimat® was performed in a real-life setting to investigate its effectiveness with regard to physical functioning and tolerability. METHODS Patients with chronic obstructive pulmonary disease (COPD; n = 1,230; mean age, 65.5 years) received tiotropium 5 μg once daily via Respimat® Soft Inhaler for 6 weeks in an open-label observational study. At baseline and week 6, patients completed the Physical Function subdomain [PF-10] of the Short Form (SF) 36 questionnaire. RESULTS Improvement in standardized PF-10 score of ≥10 points was achieved by 61.5% of patients. Mean (SD) standardized PF-10 scores improved by 13.4 (15.9) points, from 49.0 (24.5) to 62.3 points (23.5; P < 0.001). Results in smokers (n = 435) were not significantly different to those in nonsmokers. The general condition of patients improved during treatment. Adverse events were reported by 4.0% of patients and were chiefly respiratory symptoms and dry mouth. CONCLUSION In COPD patients receiving tiotropium Respimat® in daily practice, physical function improved rapidly within 6 weeks of treatment, irrespective of smoking status.
Collapse
Affiliation(s)
- Heike Rau-Berger
- Medical Affairs Germany, Respiratory Medicine, Boehringer Ingelheim Pharma GmbH and Co. KG, Ingelheim
| | | | - Thomas Glaab
- Medical Affairs Germany, Respiratory Medicine, Boehringer Ingelheim Pharma GmbH and Co. KG, Ingelheim
| |
Collapse
|
30
|
Hodder R, Price D. Patient preferences for inhaler devices in chronic obstructive pulmonary disease: experience with Respimat Soft Mist inhaler. Int J Chron Obstruct Pulmon Dis 2009; 4:381-90. [PMID: 19888356 PMCID: PMC2829861 DOI: 10.2147/copd.s3391] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2009] [Indexed: 11/23/2022] Open
Abstract
Current guidelines for the management of chronic obstructive pulmonary disease (COPD) recommend the regular use of inhaled bronchodilator therapy in order to relieve symptoms and prevent exacerbations. A variety of inhaler devices are currently available to COPD patients, and the choice of device is an important consideration because it can influence patients' adherence to treatment, and thus potentially affect the long-term outcome. The Respimat((R)) Soft Mist Inhaler (SMI) generates a slow-moving aerosol with a high fine particle fraction, resulting in deposition of a higher proportion of the dose in the lungs than pressurized metered-dose inhalers (pMDIs) or some dry powder inhalers (DPIs). We review clinical studies of inhaler satisfaction and preference comparing Respimat((R)) SMI against other inhalers in COPD patients. Using objective and validated patient satisfaction instruments, Respimat((R)) SMI was consistently shown to be well accepted by COPD patients, largely due to its inhalation and handling characteristics. In comparative studies with pMDIs, the patient total satisfaction score with Respimat((R)) SMI was statistically and clinically significantly higher than with the pMDI. In comparative studies with DPIs, the total satisfaction score was statistically significantly higher than for the Turbuhaler((R)) DPI, but only the performance domain of satisfaction was clinically significantly higher for Respimat((R)) SMI. Whether the observed higher levels of patient satisfaction reported with Respimat((R)) SMI might be expected to result in improved adherence to therapy and thus provide benefits consistent with those recently shown to be associated with sustained bronchodilator treatment in patients with COPD remains to be proven.
Collapse
Affiliation(s)
- Richard Hodder
- Divisions of Pulmonary and Critical Care, University of Ottawa, Ottawa, Ontario, Canada.
| | | |
Collapse
|