1
|
Tan HT, Smith PF, Zheng Y. Time-dependent effects of acoustic trauma and tinnitus on extracellular levels of amino acids in the inferior colliculus of rats. Hear Res 2024; 443:108948. [PMID: 38219615 DOI: 10.1016/j.heares.2024.108948] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 12/19/2023] [Accepted: 01/02/2024] [Indexed: 01/16/2024]
Abstract
Chronic tinnitus is a debilitating condition with very few management options. Acoustic trauma that causes tinnitus has been shown to induce neuronal hyperactivity in multiple brain areas in the auditory pathway, including the inferior colliculus. This neuronal hyperactivity could be attributed to an imbalance between excitatory and inhibitory neurotransmission. However, it is not clear how the levels of neurotransmitters, especially neurotransmitters in the extracellular space, change over time following acoustic trauma and the development of tinnitus. In the present study, a range of amino acids were measured in the inferior colliculus of rats during acoustic trauma as well as at 1 week and 5 months post-trauma using in vivo microdialysis and high-performance liquid chromatography. Amino acid levels in response to sound stimulation were also measured at 1 week and 5 months post-trauma. It was found that unilateral exposure to a 16 kHz pure tone at 115 dB SPL for 1 h caused immediate hearing loss in all the animals and chronic tinnitus in 58 % of the animals. Comparing to the sham condition, extracellular levels of GABA were significantly increased at both the acute and 1 week time points after acoustic trauma. However, there was no significant difference in any of the amino acid levels measured between sham, tinnitus positive and tinnitus negative animals at 5 months post-trauma. There was also no clear pattern in the relationship between neurochemical changes and sound frequency/acoustic trauma/tinnitus status, which might be due to the relatively poorer temporal resolution of the microdialysis compared to electrophysiological responses.
Collapse
Affiliation(s)
- Huey Tieng Tan
- Department of Pharmacology and Toxicology, School of Biomedical Sciences, University of Otago, Dunedin, New Zealand; Brain Health Research Centre, University of Otago, Dunedin, New Zealand; Eisdell Moore Centre for Research on Hearing and Balance Disorders, University of Auckland, New Zealand
| | - Paul F Smith
- Department of Pharmacology and Toxicology, School of Biomedical Sciences, University of Otago, Dunedin, New Zealand; Brain Health Research Centre, University of Otago, Dunedin, New Zealand; Eisdell Moore Centre for Research on Hearing and Balance Disorders, University of Auckland, New Zealand
| | - Yiwen Zheng
- Department of Pharmacology and Toxicology, School of Biomedical Sciences, University of Otago, Dunedin, New Zealand; Brain Health Research Centre, University of Otago, Dunedin, New Zealand; Eisdell Moore Centre for Research on Hearing and Balance Disorders, University of Auckland, New Zealand.
| |
Collapse
|
2
|
Xu X, Zuo Y, Chen S, Hatami A, Gu H. Advancements in Brain Research: The In Vivo/In Vitro Electrochemical Detection of Neurochemicals. BIOSENSORS 2024; 14:125. [PMID: 38534232 DOI: 10.3390/bios14030125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 02/12/2024] [Accepted: 02/20/2024] [Indexed: 03/28/2024]
Abstract
Neurochemicals, crucial for nervous system function, influence vital bodily processes and their fluctuations are linked to neurodegenerative diseases and mental health conditions. Monitoring these compounds is pivotal, yet the intricate nature of the central nervous system poses challenges. Researchers have devised methods, notably electrochemical sensing with micro-nanoscale electrodes, offering high-resolution monitoring despite low concentrations and rapid changes. Implantable sensors enable precise detection in brain tissues with minimal damage, while microdialysis-coupled platforms allow in vivo sampling and subsequent in vitro analysis, addressing the selectivity issues seen in other methods. While lacking temporal resolution, techniques like HPLC and CE complement electrochemical sensing's selectivity, particularly for structurally similar neurochemicals. This review covers essential neurochemicals and explores miniaturized electrochemical sensors for brain analysis, emphasizing microdialysis integration. It discusses the pros and cons of these techniques, forecasting electrochemical sensing's future in neuroscience research. Overall, this comprehensive review outlines the evolution, strengths, and potential applications of electrochemical sensing in the study of neurochemicals, offering insights into future advancements in the field.
Collapse
Affiliation(s)
- Xiaoxuan Xu
- Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
| | - Yimei Zuo
- Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
| | - Shu Chen
- Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
| | - Amir Hatami
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Prof. Sobouti Boulevard, P.O. Box 45195-1159, Zanjan 45137-66731, Iran
- Department of Chemistry and Molecular Biology, University of Gothenburg, 405 30 Gothenburg, Sweden
| | - Hui Gu
- Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
- Department of Chemistry and Molecular Biology, University of Gothenburg, 405 30 Gothenburg, Sweden
| |
Collapse
|
3
|
Hou J, Strand-Amundsen R, Martinsen ØG. Detection of physiological concentrations of GABA using dielectric spectroscopy - A pilot study. JOURNAL OF ELECTRICAL BIOIMPEDANCE 2023; 14:47-52. [PMID: 38162815 PMCID: PMC10750319 DOI: 10.2478/joeb-2023-0006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Indexed: 01/03/2024]
Abstract
Gamma-aminobutyric acid (GABA) is a major inhibitory neurotransmitter that is present at a relatively low level throughout the normal adult human brain. Abnormal GABA levels are found in people with neurodegenerative disorders such as Parkinson's disease, epilepsy, schizophrenia, depression, and others. Being able to measure the GABA concentration would be beneficial for patient groups with fluctuating GABA levels for better diagnosis and treatment. In this study, we explore the feasibility of using dielectric relaxation spectroscopy for the detection of GABA concentrations within a physiological range, with the perspective of miniaturization and use during implantation. Utilizing machine learning techniques, we were able to differentiate GABA concentrations down to 5 μm. This work investigates a novel use of dielectric relaxation spectroscopy, to assess if physiological GABA concentrations can be detected through permittivity measurements.
Collapse
Affiliation(s)
- Jie Hou
- Department of Physics, University of Oslo, 0316Oslo, Norway
| | - Runar Strand-Amundsen
- Department of Clinical and Biomedical Engineering, Oslo University Hospital, 0372Oslo, Norway
| | - Ørjan G. Martinsen
- Department of Physics, University of Oslo, 0316Oslo, Norway
- Department of Clinical and Biomedical Engineering, Oslo University Hospital, 0372Oslo, Norway
| |
Collapse
|
4
|
Abrantes M, Rodrigues D, Domingues T, Nemala SS, Monteiro P, Borme J, Alpuim P, Jacinto L. Ultrasensitive dopamine detection with graphene aptasensor multitransistor arrays. J Nanobiotechnology 2022; 20:495. [DOI: 10.1186/s12951-022-01695-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 11/01/2022] [Indexed: 11/26/2022] Open
Abstract
AbstractDetecting physiological levels of neurotransmitters in biological samples can advance our understanding of brain disorders and lead to improved diagnostics and therapeutics. However, neurotransmitter sensors for real-world applications must reliably detect low concentrations of target analytes from small volume working samples. Herein, a platform for robust and ultrasensitive detection of dopamine, an essential neurotransmitter that underlies several brain disorders, based on graphene multitransistor arrays (gMTAs) functionalized with a selective DNA aptamer is presented. High-yield scalable methodologies optimized at the wafer level were employed to integrate multiple graphene transistors on small-size chips (4.5 × 4.5 mm). The multiple sensor array configuration permits independent and simultaneous replicate measurements of the same sample that produce robust average data, reducing sources of measurement variability. This procedure allowed sensitive and reproducible dopamine detection in ultra-low concentrations from small volume samples across physiological buffers and high ionic strength complex biological samples. The obtained limit-of-detection was 1 aM (10–18) with dynamic detection ranges spanning 10 orders of magnitude up to 100 µM (10–8), and a 22 mV/decade peak sensitivity in artificial cerebral spinal fluid. Dopamine detection in dopamine-depleted brain homogenates spiked with dopamine was also possible with a LOD of 1 aM, overcoming sensitivity losses typically observed in ion-sensitive sensors in complex biological samples. Furthermore, we show that our gMTAs platform can detect minimal changes in dopamine concentrations in small working volume samples (2 µL) of cerebral spinal fluid samples obtained from a mouse model of Parkinson’s Disease. The platform presented in this work can lead the way to graphene-based neurotransmitter sensors suitable for real-world academic and pre-clinical pharmaceutical research as well as clinical diagnosis.
Collapse
|
5
|
Kaur H, Siwal SS, Saini RV, Singh N, Thakur VK. Significance of an Electrochemical Sensor and Nanocomposites: Toward the Electrocatalytic Detection of Neurotransmitters and Their Importance within the Physiological System. ACS NANOSCIENCE AU 2022; 3:1-27. [PMID: 37101467 PMCID: PMC10125382 DOI: 10.1021/acsnanoscienceau.2c00039] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/17/2022] [Accepted: 10/17/2022] [Indexed: 11/07/2022]
Abstract
A prominent neurotransmitter (NT), dopamine (DA), is a chemical messenger that transmits signals between one neuron to the next to pass on a signal to and from the central nervous system (CNS). The imbalanced concentration of DA may cause numerous neurological sicknesses and syndromes, for example, Parkinson's disease (PD) and schizophrenia. There are many types of NTs in the brain, including epinephrine, norepinephrine (NE), serotonin, and glutamate. Electrochemical sensors have offered a creative direction to biomedical analysis and testing. Researches are in progress to improve the performance of sensors and develop new protocols for sensor design. This review article focuses on the area of sensor growth to discover the applicability of polymers and metallic particles and composite materials as tools in electrochemical sensor surface incorporation. Electrochemical sensors have attracted the attention of researchers as they possess high sensitivity, quick reaction rate, good controllability, and instantaneous detection. Efficient complex materials provide considerable benefits for biological detection as they have exclusive chemical and physical properties. Due to distinctive electrocatalytic characteristics, metallic nanoparticles add fascinating traits to materials that depend on the material's morphology and size. Herein, we have collected much information on NTs and their importance within the physiological system. Furthermore, the electrochemical sensors and corresponding techniques (such as voltammetric, amperometry, impedance, and chronoamperometry) and the different types of electrodes' roles in the analysis of NTs are discussed. Furthermore, other methods for detecting NTs include optical and microdialysis methods. Finally, we show the advantages and disadvantages of different techniques and conclude remarks with future perspectives.
Collapse
Affiliation(s)
- Harjot Kaur
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Samarjeet Singh Siwal
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Reena V. Saini
- Department of Biotechnology, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Nirankar Singh
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Vijay Kumar Thakur
- Biorefining and Advanced Materials Research Center, Scotland’s Rural College (SRUC), Kings Buildings, Edinburgh EH9 3JG, United Kingdom
- School of Engineering, University of Petroleum & Energy Studies (UPES), Dehradun, Uttarakhand 248007, India
- Centre for Research & Development, Chandigarh University, Mohali, Punjab 140413, India
| |
Collapse
|
6
|
Siwadamrongpong R, Sato N, Sugie K, Ohta Y, Haruta M, Takehara H, Tashiro H, Sasagawa K, Ohta J. Development of Compact Readout Device for Neural Observation System using Fluorescence Imaging and Fast-scan Cyclic Voltammetry. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:4864-4867. [PMID: 36085844 DOI: 10.1109/embc48229.2022.9871016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
A readout device for a dual-functional neural observation system is presented. The authors separately developed the reading operation of an implantable CMOS image sensor and a setup for fast-scan cyclic voltammetry and implemented them together in a microcontroller-based device. The developed imaging readout device with a size of [Formula: see text] can reach the highest reading rate of 160 fps with a 120×268 pixel image sensor. The voltammetry function was verified through an experiment using commercial carbon fiber electrodes in phosphate-buffered saline. When the imaging is sequentially operated with 400 V/s-scan rate voltammetry from -0.4 to 1.3 V, the system can operate at up to 60 fps. With this system, calcium imaging and dopamine recording in a freely behaving mouse can be achieved together in a simpler manner. This study aims to be the basis for the development of an implantable multi-functional sensor.
Collapse
|
7
|
Nguyen TNH, Nolan JK, Cheng X, Park H, Wang Y, Lam S, Lee H, Kim SJ, Shi R, Chubykin AA, Lee H. Fabrication and ex vivo evaluation of activated carbon-Pt microparticle based glutamate biosensor. J Electroanal Chem (Lausanne) 2020; 866. [PMID: 32489342 DOI: 10.1016/j.jelechem.2020.114136] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
As one of the most abundant neurotransmitters in the brain and the spinal cord, glutamate plays many important roles in the nervous system. Precise information about the level of glutamate in the extracellular space of living brain tissue may provide new insights on fundamental understanding of the role of glutamate in neurological disorders as well as neurophysiological phenomena. Electrochemical sensor has emerged as a promising solution that can satisfy the requirement for highly reliable and continuous monitoring method with good spatiotemporal resolution for characterization of extracellular glutamate concentration. Recently, we published a method to create a simple printable glutamate biosensor using platinum nanoparticles. In this work, we introduce an even simpler and lower cost conductive polymer composite using commercially available activated carbon with platinum microparticles to easily fabricate highly sensitive glutamate biosensor using direct ink writing method. The fabricated biosensors are functionality superior than previously reported with the sensitivity of 5.73 ± 0.078 nA μM-1 mm-2, detection limit of 0.03 μM, response time less than or equal to 1 s, and a linear range from 1 μM up to 925 μM. In this study, we utilize astrocyte cell culture to demonstrate our biosensor's ability to monitor glutamate uptake process. We also demonstrate direct measurement of glutamate release from optogenetic stimulation in mouse primary visual cortex (V1) brain slices.
Collapse
Affiliation(s)
- Tran N H Nguyen
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA
| | - James K Nolan
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA
| | - Xi Cheng
- Department of Biological Sciences, Purdue Institute for Integrative Neuroscience, Purdue University, West Lafayette, IN, USA
| | - Hyunsu Park
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA
| | - Yi Wang
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA
| | - Stephanie Lam
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA
| | - Hyungwoo Lee
- Samsung Advanced Institute of Technology, Suwon, South Korea
| | - Sang Joon Kim
- Samsung Advanced Institute of Technology, Suwon, South Korea
| | - Riyi Shi
- College of Veterinary Medicine, Purdue University, West Lafayette, IN, USA
| | - Alexander A Chubykin
- Department of Biological Sciences, Purdue Institute for Integrative Neuroscience, Purdue University, West Lafayette, IN, USA
| | - Hyowon Lee
- Weldon School of Biomedical Engineering, Birck Nanotechnology Center, Center for Implantable Device, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
8
|
Chauhan N, Soni S, Agrawal P, Balhara YPS, Jain U. Recent advancement in nanosensors for neurotransmitters detection: Present and future perspective. Process Biochem 2020. [DOI: 10.1016/j.procbio.2019.12.016] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
9
|
Arumugasamy SK, Chellasamy G, Gopi S, Govindaraju S, Yun K. Current advances in the detection of neurotransmitters by nanomaterials: An update. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2019.115766] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
10
|
Burmeister JJ, Price DA, Pomerleau F, Huettl P, Quintero JE, Gerhardt GA. Challenges of simultaneous measurements of brain extracellular GABA and glutamate in vivo using enzyme-coated microelectrode arrays. J Neurosci Methods 2020; 329:108435. [PMID: 31600528 PMCID: PMC6924626 DOI: 10.1016/j.jneumeth.2019.108435] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Revised: 08/19/2019] [Accepted: 09/10/2019] [Indexed: 10/25/2022]
Abstract
BACKGROUND Although GABA is the major inhibitory neurotransmitter in the CNS, quantifying in vivo GABA levels has been challenging. The ability to co-monitor both GABA and the major excitatory neurotransmitter, glutamate, would be a powerful tool in both research and clinical settings. NEW METHOD Ceramic-based microelectrode arrays (MEAs) were used to quantify gamma-aminobutyric acid (GABA) by employing a dual-enzyme reaction scheme including GABase and glutamate oxidase (GluOx). Glutamate was simultaneously quantified on adjacent recording sites coated with GluOx alone. Endogenous glutamate was subtracted from the combined GABA and glutamate signal to yield a pure GABA concentration. RESULTS Electrode sensitivity to GABA in conventional, stirred in vitro calibrations at pH 7.4 did not match the in vivo sensitivity due to diffusional losses. Non-stirred calibrations in agarose or stirred calibrations at pH 8.6 were used to match the in vivo GABA sensitivity. In vivo data collected in the rat brain demonstrated feasibility of the GABA/glutamate MEA including uptake of locally applied GABA, KCl-evoked GABA release and modulation of endogenous GABA with vigabatrin. COMPARISON WITH EXISTING METHODS Implantable enzyme-coated microelectrode arrays have better temporal and spatial resolution than existing off-line methods. However, interpretation of results can be complicated due to the multiple recording site and dual enzyme approach. CONCLUSIONS The initial in vitro and in vivo studies supported that the new MEA configuration may be a viable platform for combined GABA and glutamate measures in the CNS extending the previous reports to in vivo GABA detection. The challenges of this approach are emphasized.
Collapse
Affiliation(s)
- Jason J Burmeister
- Department of Neuroscience, Center for Microelectrode Technology, University of Kentucky, College of Medicine, Lexington, KY, USA
| | - David A Price
- Department of Neuroscience, Center for Microelectrode Technology, University of Kentucky, College of Medicine, Lexington, KY, USA
| | - François Pomerleau
- Department of Neuroscience, Center for Microelectrode Technology, University of Kentucky, College of Medicine, Lexington, KY, USA
| | - Peter Huettl
- Department of Neuroscience, Center for Microelectrode Technology, University of Kentucky, College of Medicine, Lexington, KY, USA
| | - Jorge E Quintero
- Department of Neuroscience, Center for Microelectrode Technology, University of Kentucky, College of Medicine, Lexington, KY, USA
| | - Greg A Gerhardt
- Department of Neuroscience, Center for Microelectrode Technology, University of Kentucky, College of Medicine, Lexington, KY, USA.
| |
Collapse
|
11
|
Hossain I, Tan C, Doughty PT, Dutta G, Murray TA, Siddiqui S, Iasemidis L, Arumugam PU. A Novel Microbiosensor Microarray for Continuous ex Vivo Monitoring of Gamma-Aminobutyric Acid in Real-Time. Front Neurosci 2018; 12:500. [PMID: 30131664 PMCID: PMC6090213 DOI: 10.3389/fnins.2018.00500] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2018] [Accepted: 07/03/2018] [Indexed: 12/23/2022] Open
Abstract
Gamma-aminobutyric acid (GABA) is a major inhibitory neurotransmitter that is essential for normal brain function. It is involved in multiple neuronal activities, including plasticity, information processing, and network synchronization. Abnormal GABA levels result in severe brain disorders and therefore GABA has been the target of a wide range of drug therapeutics. GABA being non-electroactive is challenging to detect in real-time. To date, GABA is detected mainly via microdialysis with a high-performance liquid chromatography (HPLC) system that employs electrochemical (EC) and spectroscopic methodology. However, these systems are bulky and unsuitable for real-time continuous monitoring. As opposed to microdialysis, biosensors are easy to miniaturize and are highly suitable for in vivo studies; they selectively oxidize GABA into a secondary electroactive product (usually hydrogen peroxide, H2O2) in the presence of enzymes, which is then detected by amperometry. Unfortunately, this method requires a rather cumbersome process with prereactors and relies on externally applied reagents. Here, we report the design and implementation of a GABA microarray probe that operates on a newly conceived principle. It consists of two microbiosensors, one for glutamate (Glu) and one for GABA detection, modified with glutamate oxidase and GABASE enzymes, respectively. By simultaneously measuring and subtracting the H2O2 oxidation currents generated from these microbiosensors, GABA and Glu can be detected continuously in real-time in vitro and ex vivo and without the addition of any externally applied reagents. The detection of GABA by this probe is based upon the in-situ generation of α-ketoglutarate from the Glu oxidation that takes place at the Glu microbiosensor. A GABA sensitivity of 36 ± 2.5 pA μM-1cm-2, which is 26-fold higher than reported in the literature, and a limit of detection of 2 ± 0.12 μM were achieved in an in vitro setting. The GABA probe was successfully tested in an adult rat brain slice preparation. These results demonstrate that the developed GABA probe constitutes a novel and powerful neuroscientific tool that could be employed in the future for in vivo longitudinal studies of the combined role of GABA and Glu (a major excitatory neurotransmitter) signaling in brain disorders, such as epilepsy and traumatic brain injury, as well as in preclinical trials of potential therapeutic agents for the treatment of these disorders.
Collapse
Affiliation(s)
- Imran Hossain
- Institute for Micromanufacturing, Louisiana Tech University, Ruston, LA, United States
| | - Chao Tan
- Institute for Micromanufacturing, Louisiana Tech University, Ruston, LA, United States.,Center for Biomedical Engineering and Rehabilitation Science, Louisiana Tech University, Ruston, LA, United States
| | - Phillip T Doughty
- Center for Biomedical Engineering and Rehabilitation Science, Louisiana Tech University, Ruston, LA, United States
| | - Gaurab Dutta
- Institute for Micromanufacturing, Louisiana Tech University, Ruston, LA, United States
| | - Teresa A Murray
- Center for Biomedical Engineering and Rehabilitation Science, Louisiana Tech University, Ruston, LA, United States
| | - Shabnam Siddiqui
- Center for Biomedical Engineering and Rehabilitation Science, Louisiana Tech University, Ruston, LA, United States
| | - Leonidas Iasemidis
- Center for Biomedical Engineering and Rehabilitation Science, Louisiana Tech University, Ruston, LA, United States
| | - Prabhu U Arumugam
- Institute for Micromanufacturing, Louisiana Tech University, Ruston, LA, United States.,Center for Biomedical Engineering and Rehabilitation Science, Louisiana Tech University, Ruston, LA, United States
| |
Collapse
|
12
|
Kelly P, Hudry E, Hou SS, Bacskai BJ. In Vivo Two Photon Imaging of Astrocytic Structure and Function in Alzheimer's Disease. Front Aging Neurosci 2018; 10:219. [PMID: 30072889 PMCID: PMC6060286 DOI: 10.3389/fnagi.2018.00219] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Accepted: 06/26/2018] [Indexed: 12/17/2022] Open
Abstract
The physiological function of the neurovascular unit is critically dependent upon the complex structure and functions of astrocytes for optimal preservation of cerebral homeostasis. While it has been shown that astrocytes exhibit aberrant changes in both structure and function in transgenic murine models of Alzheimer’s disease (AD), it is not fully understood how this altered phenotype contributes to the pathogenesis of AD or whether this alteration predicts a therapeutic target in AD. The mechanisms underlying the spatiotemporal relationship between astrocytes, neurons and the vasculature in their orchestrated regulation of local cerebral flow in active brain regions has not been fully elucidated in brain physiology and in AD. As there is an incredible urgency to identify therapeutic targets that are well-tolerated and efficacious in protecting the brain against the pathological impact of AD, here we use the current body of literature to evaluate the hypothesis that pathological changes in astrocytes are central to the pathogenesis of AD. We also examine the current tools available to assess astrocytic calcium signaling in the living murine brain as it has an important role in the complex interaction between astrocytes, neurons and the vasculature. Furthermore, we discuss the altered function of astrocytes in their interaction with neurons in the preservation of glutamate homeostasis and additionally address the role of astrocytes at the vascular interface and their contribution to functional hyperemia within the living murine brain in health and in AD.
Collapse
Affiliation(s)
- Patricia Kelly
- Massachusetts Institute for Neurodegenerative Disease, Department of Neurology, Massachusetts General Hospital, Harvard Medical School, Harvard University, Boston, MA, United States
| | - Eloise Hudry
- Massachusetts Institute for Neurodegenerative Disease, Department of Neurology, Massachusetts General Hospital, Harvard Medical School, Harvard University, Boston, MA, United States
| | - Steven S Hou
- Massachusetts Institute for Neurodegenerative Disease, Department of Neurology, Massachusetts General Hospital, Harvard Medical School, Harvard University, Boston, MA, United States
| | - Brian J Bacskai
- Massachusetts Institute for Neurodegenerative Disease, Department of Neurology, Massachusetts General Hospital, Harvard Medical School, Harvard University, Boston, MA, United States
| |
Collapse
|
13
|
Ortega-Ibarra J, López-Pérez S, Morales-Villagrán A. An electrochemiluminescent method for glutamate measurement in small microdialysate samples in asphyxiated young rats. LUMINESCENCE 2017; 33:47-53. [PMID: 28718955 DOI: 10.1002/bio.3371] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 05/16/2017] [Accepted: 05/28/2017] [Indexed: 11/08/2022]
Abstract
Glutamate (Glu) quantification has been performed by a combination of intracerebral microdialysis through which the samples are obtained and analyzed by high performance liquid chromatography (HPLC); its measurement requires a large expenditure of time (15-30 min per sample) and special training. Therefore, an alternative method is presented here, based on the electrochemiluminescence produced by the use of an enzymatic reactor, containing glutamate-oxidase, mixed and incubated with microdialysate from dorsal striatum (DS) and prefrontal cortex (PFC) of young rats asphyxiated during the neonatal period, under a global asphyxia model in order to test this method. Using this approach, we found high extracellular Glu concentration in the DS of asphyxiated animals, but only during K+ stimulation, while in the PFC, only a delay in the rise of Glu after K+ stimulation was observed, without any difference in extracellular Glu content when compared with controls. This new method permitted a fast measurement of Glu in brain dialysate samples, it significantly reduces the cost of the analysis per sample, since only a single device and pump are needed without using columns and high pressure inside the system or complex hardware and software to control pumps, detector, fraction collector or any other peripheral used in HPLC.
Collapse
Affiliation(s)
- Jorge Ortega-Ibarra
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico
| | - Silvia López-Pérez
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico
| | - Alberto Morales-Villagrán
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico
| |
Collapse
|
14
|
Enrico P, Diana M. On the Accuracy of In Vivo Ethanol and Acetaldehyde Monitoring, a Key Tile in the Puzzle of Acetaldehyde as a Neuroactive Agent. Front Behav Neurosci 2017; 11:97. [PMID: 28611604 PMCID: PMC5447755 DOI: 10.3389/fnbeh.2017.00097] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Accepted: 05/09/2017] [Indexed: 11/18/2022] Open
Abstract
Over the last 20 years researchers have explored the postulated role of acetaldehyde (ACD) as a mediator of some of the actions of ethanol (EtOH) in the central nervous system (CNS). However, efforts have been hampered mainly by the difficulty of directly measuring in vivo EtOH and ACD levels in the CNS and thus, our knowledge is based on indirect evidences. Although technically challenging, the development of reliable methods for in vivo measurement of ACD and EtOH is of paramount importance to solve the “puzzle of acetaldehyde as a neuroactive agent.” In this short review we discuss the recent advances on brain EtOH pharmacokinetic and state-of-the-art available techniques that could be used for in vivo detect EtOH and ACD both non-invasively (magnetic resonance spectroscopy), and invasively (microdialysis and biosensors). Among the different in vivo sampling techniques described, particular emphasis is paid to the field of enzyme-based amperometric biosensors. Biosensors have gained much attention in recent years for their ability to online monitor biological signals in vivo, and several micro- and nano-structured devices have been successfully used for in vivo studies. Owing to their high temporal and spatial resolution, biosensors could provide the adequate technology for studying in vivo EtOH pharmacokinetic.
Collapse
Affiliation(s)
- Paolo Enrico
- Department of Biomedical Sciences, University of SassariSassari, Italy
| | - Marco Diana
- 'G. Minardi' Cognitive Neuroscience Laboratory, Department of Chemistry and Pharmacy, University of SassariSassari, Italy
| |
Collapse
|
15
|
Morales-Villagrán A, Pardo-Peña K, Medina-Ceja L, López-Pérez S. A microdialysis and enzymatic reactor sensing procedure for the simultaneous registration of online glutamate measurements at high temporal resolution during epileptiform activity. J Neurochem 2016; 139:886-896. [DOI: 10.1111/jnc.13850] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Revised: 08/10/2016] [Accepted: 09/01/2016] [Indexed: 12/01/2022]
Affiliation(s)
- Alberto Morales-Villagrán
- Laboratory of Neurophysiology and Neurochemistry; Department of Cellular and Molecular Biology; CUCBA; University of Guadalajara; Jalisco México
| | - Kenia Pardo-Peña
- Laboratory of Neurophysiology and Neurochemistry; Department of Cellular and Molecular Biology; CUCBA; University of Guadalajara; Jalisco México
| | - Laura Medina-Ceja
- Laboratory of Neurophysiology and Neurochemistry; Department of Cellular and Molecular Biology; CUCBA; University of Guadalajara; Jalisco México
| | - Silvia López-Pérez
- Laboratory of Neurophysiology and Neurochemistry; Department of Cellular and Molecular Biology; CUCBA; University of Guadalajara; Jalisco México
| |
Collapse
|
16
|
Mamidala MP, Rajesh N, Rajesh V. Mass spectrometric evaluation of neurotransmitter levels in IMR 32 cell line in response to Ayurvedic medicines. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:1413-1422. [PMID: 27197034 DOI: 10.1002/rcm.7571] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 03/15/2016] [Accepted: 03/16/2016] [Indexed: 06/05/2023]
Abstract
RATIONALE Ayurvedic herbal medicines are administered as part of disease management for many neurodevelopmental disorders like Autism Spectrum Disorder (ASD) and linked comorbid challenges. The biochemistry of the behavioral abnormalities as observed in comorbid conditions is already reported to involve neurotransmitters like gamma-aminobutyric acid (GABA), serotonin (5-HT) and dopamine (DA). The aim of our study is to evaluate the effect of ayurvedic medicines on neurotransmitter levels in IMR 32. Such a study will give some insight into the molecular mechanism of the action of these medicines and help us to understand their contributions in neurotransmitter homeostasis. METHODS Solutions of Brahmi, Brahmi vati, Brahmi ghrita and Saraswata ghrita, each at 50 μM, were added to differentiated IMR 32 cells and grown for 24 h. The cell secretion was analysed by ultra-fast liquid chromatography/mass spectrometry (UFLC/MS) in electrospray ionisation (ESI) mode for the neurotransmitters DA, 5-HT and GABA. The mobile phase selected was 0.1% formic acid with 15 μg/mL Na2 -EDTA (A) and 0.1% formic acid in acetonitrile (B) introduced in the ratio of 92:8. RESULTS All neurotransmitters under study were eluted within 7 min with GABA eluting at 3.82 min, 5-HT at 4.48 min and DA at 5.47 min, respectively. Linearity was excellent with a correlation coefficient (R(2) ) of 0.999; repeatability and accuracy were also within acceptable range. All herbal drugs evaluated increased the neurotransmitter levels and Brahmi vati increased the neurotransmitter levels to a larger extent. CONCLUSIONS Decreased levels of neurotransmitters were observed in behavioral abnormalities which were also observed in children with ASD. Herbal medicines given as part of ayurvedic medicine increased the neurotransmitter levels in IMR 32. Thus, these ayurvedic medicines when prescribed to children with ASD might alleviate the abnormal behavioral symptoms by maintaining neurotransmitter homeostasis. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Madhu Poornima Mamidala
- Department of Biological Sciences, Birla Institute of Technology & Science, Pilani - Hyderabad Campus, India
| | - N Rajesh
- Department of Chemistry, Birla Institute of Technology & Science, Pilani - Hyderabad Campus, India
| | - Vidya Rajesh
- Department of Biological Sciences, Birla Institute of Technology & Science, Pilani - Hyderabad Campus, India
| |
Collapse
|
17
|
Young B, Kalanuria A, Kumar M, Burke K, Balu R, Amendolia O, McNulty K, Marion B, Beckmann B, Ciocco L, Miller K, Schuele D, Maloney-Wilensky E, Frangos S, Wright D. Cerebral Microdialysis. Crit Care Nurs Clin North Am 2016; 28:109-24. [DOI: 10.1016/j.cnc.2015.09.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
18
|
Crecelius AC, Schubert US, von Eggeling F. MALDI mass spectrometric imaging meets “omics”: recent advances in the fruitful marriage. Analyst 2015; 140:5806-20. [DOI: 10.1039/c5an00990a] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Matrix-assisted laser desorption/ionization mass spectrometric imaging (MALDI MSI) is a method that allows the investigation of the molecular content of surfaces, in particular, tissues, within its morphological context.
Collapse
Affiliation(s)
- A. C. Crecelius
- Laboratory of Organic and Macromolecular Chemistry (IOMC)
- Friedrich Schiller University Jena
- 07743 Jena
- Germany
- Jena Center for Soft Matter (JCSM)
| | - U. S. Schubert
- Laboratory of Organic and Macromolecular Chemistry (IOMC)
- Friedrich Schiller University Jena
- 07743 Jena
- Germany
- Jena Center for Soft Matter (JCSM)
| | - F. von Eggeling
- Jena Center for Soft Matter (JCSM)
- Friedrich Schiller University Jena
- 07743 Jena
- Germany
- Institute of Physical Chemistry
| |
Collapse
|