1
|
Jafarian J, Shahrabi-Farahani S, Ferreira CF, Stewart CW, Luepke P. Histological Evaluation of Alveolar Ridge Preservation Using Different Bone Grafts: Clinical Study Analysis Part II. J ORAL IMPLANTOL 2024; 50:260-265. [PMID: 38660739 DOI: 10.1563/aaid-joi-d-23-00060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
To compare histologically the percentage of bone formation 12-20 weeks after ridge augmentation using 2 different techniques. Tooth loss is associated with 3-dimensional bone remodeling and ridge atrophy. Ridge preservation procedures can prevent alveolar bone volume loss. Different techniques and materials are used to preserve the alveolar ridge. Computer-generated randomization software was used to assign 2 ridge preservation techniques for 11 extraction sites. In group I, type I bovine Achilles tendon collagen plugs with bioactive resorbable calcium apatite crystals (CPCAC) were placed, and in group II, cortico-cancellous bone chips (CCBC) mix and an expanded polytetrafluoroethylene (ePTFE) barrier membrane were placed. The histomorphometric studies were performed using a computer-based image analysis system (ImageJ 1.4, National Institute of Health, Bethesda, Md) to calculate the pixel area of bone tissue and the remaining bone graft material. The histomorphometric data were analyzed using a Student t test to compare the measurements between the 2 experimental groups. This parametric statistical test was employed to determine if there were any statistically significant differences in the quantitative histological parameters between the groups. The sockets that received CPCAC showed a lower (31.89%) percentage of native bone surface area compared with the CCBC group (43.87%). However, the difference was not statistically significant (P < .05). In addition, the CPCAC group showed evidence of foreign-body reaction. The CCBC graft covered with an ePTFE barrier may induce more bone formation with minimal inflammation in an extraction socket compared with a collagen plug with calcium apatite crystals. In addition, histological analysis of the CPCAC graft showed evidence of foreign-body reaction, which indicates a negative clinical impact.
Collapse
Affiliation(s)
| | - Shokoufeh Shahrabi-Farahani
- Department of Diagnostic Sciences, University of Tennessee Health Science Center, College of Dentistry, Memphis, TN, USA
| | - Cimara Fortes Ferreira
- Department of Periodontology, University of Tennessee College of Dentistry, Memphis, TN, USA
| | - Colette Whitley Stewart
- Department of Dental Hygiene, University of Tennessee College of Dentistry, Memphis, TN, USA
| | - Paul Luepke
- Department of Periodontology, University of Tennessee College of Dentistry, Memphis, TN, USA
| |
Collapse
|
2
|
Song KX, Ji SL, Zhao YJ, Zhang HR, Ma RX, Zhang JY, Hu YC. Effects of demineralization mode and particle size of allogeneic bone powder on its physical and chemical properties. Cell Tissue Bank 2023; 24:203-210. [PMID: 35831637 DOI: 10.1007/s10561-022-10025-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 06/23/2022] [Indexed: 11/25/2022]
Abstract
At present, the commonly used allogeneic bone powder in the clinic can be divided into nondemineralized bone matrix and demineralized bone matrix (DBM). Commonly used demineralizers include acids and ethylene diamine tetraacetic acid (EDTA). There may be some diversities between them. Also, the size of the bone particle can affects its cell compatibility and osteogenic ability. We produced different particle sizes i.e., < 75, 75-100, 100-315, 315-450, 450-650, and 650-1000 μm, and treated in three ways (nondemineralized, demineralized by EDTA, and demineralized by HCl). Scanning electron microscopy showed that the surface of the samples in each group was relatively smooth without obvious differences. The results of specific surface area and porosity analysis showed that they were significantly higher in demineralized bone powder than in nondemineralized bone powder, however, there was no significant difference between the two decalcification methods. The content of hydroxyproline in nondemineralized bone powder and EDTA-demineralized bone powder had no statistical difference, while HCl-demineralization had statistical significance compared with the former two, and the content increased with the decrease of particle size. The protein and BMP-2 extracted from HCl demineralized bone powder were significantly higher than that from nondemineralized bone powder and EDTA demineralized bone powder, and there were differences among different particle sizes. These results suggested the importance of demineralization mode and particle size of the allogenic bone powder and provided guidance for the choice of the most appropriate particle size and demineralization mode to be used in tissue bioengineering.
Collapse
Affiliation(s)
- Kun-Xiu Song
- Tianjin Medical University, Tianjin, China
- Department of Hand & Microsurgery, Binzhou Medical University Hospital, Binzhou, Shandong province, China
| | | | - Yong-Jie Zhao
- Department of Hand & Microsurgery, Binzhou Medical University Hospital, Binzhou, Shandong province, China
| | | | | | - Jing-Yu Zhang
- Department of Bone Tumor and Soft Tissue Oncology, Tianjin Hospital, 406 Jiefang Southern Road, Tianjin, 300211, China.
| | - Yong-Cheng Hu
- Department of Bone Tumor and Soft Tissue Oncology, Tianjin Hospital, 406 Jiefang Southern Road, Tianjin, 300211, China.
| |
Collapse
|
3
|
Tally WC, Temple HT, Burkus JK. Lateral lumbar interbody fusion using a cellular allogeneic bone matrix in the treatment of symptomatic degenerative lumbar disc disease and lumbar spinal instability. JOURNAL OF SPINE SURGERY 2021; 7:310-317. [PMID: 34734135 DOI: 10.21037/jss-21-28] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 07/02/2021] [Indexed: 11/06/2022]
Abstract
Background Cellular allogeneic bone grafts are used as a biologic adjuvant in lumbar spinal fusions. The clinical use of a minimally invasive extreme lateral approach to the lumbar spine has been widely adopted; however, there are few clinical studies that have documented the clinical and radiographic outcomes associated with the use of cellular allografts as an adjunct to fusion in this advanced surgical approach. Methods A consecutive series of 67 patients (34 males and 33 females) with a mean age of 66.8 years (26-85 years) who underwent single- or multilevel lateral lumbar interbody fusion (LLIF) with supplemental posterior segmental spinal fixation using a cellular allogeneic bone matrix as the only bone graft material was retrospectively reviewed by a single surgeon. Patients' preoperative and 3- and 12-month postoperative data were studied. All patients were followed for a minimum of 12 months. Standardized clinical outcome measures-36-Item Short Form Surgery (SF-36), Oswestry Disability Index (ODI), and visual analog scale (VAS) back and leg pain scores-were used to evaluate the clinical outcomes. An average of 2.25 levels was treated per patient (151 total levels). Fusion status was assessed by dynamic radiographs and computed tomography (CT) scans. The statistical method used to identify the significance of the observed changes in clinical outcomes was the paired 2-sided t-tests. Significance was ascribed to P values <0.05. Results Fusion was achieved at 142 levels (142/151; 94%). Eight levels (8/151; 5.3%) showed partial fusions and one patient (single level) had no fusion. In the group of patients with fusions, the mean back and leg pain scores showed improvement from preoperative scores at both 3 and 12 months (P<0.001). Functional outcomes showed similar clinical success in both in SF-36 and ODI scores. Conclusions The use of a cellular allogeneic bone matrix provided osteoconductive and osteoinductive components for successful spine fusions and was associated with statistically significant improvement in SF-36, VAS, and ODI scores.
Collapse
Affiliation(s)
| | - H Thomas Temple
- University of Miami, Miller School of Medicine, Kiran C. Patel Allopathic School of Medicine, Nova Southeastern University, Miami, FL, USA
| | | |
Collapse
|
4
|
Regenerative medicine: characterization of human bone matrix gelatin (BMG) and folded platelet-rich fibrin (F-PRF) membranes alone and in combination (sticky bone). Cell Tissue Bank 2021; 22:711-717. [PMID: 34061289 PMCID: PMC8558196 DOI: 10.1007/s10561-021-09925-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 04/08/2021] [Indexed: 11/11/2022]
Abstract
During the last two decades autologous platelet and leukocyte rich products (PRP; PRF), opened new perspectives in regenerative medicine. In particular regenerative dentistry played a pioneer role in the application of these products in bone regenerative cases. Many aspects of cytokines, such as, growth factor release, blood cell content and its characterization were reported, but some practical questions are still unanswered in the preparation of PRF membranes and sticky bones. A new folding technique was introduced that created a good quality, pliable, and strong F-PRF membrane with a dense fibrin network and more homogenous blood cell distribution. F-PRF produced a very promising sticky bone combined with human freeze-dried cortical bone matrix gelatin (BMG). There hasn’t been much focus on the quality and character of the applied bone and the optimal membrane/bone particle ratio has not been reported. A 0.125 g BMG/ml plasma (1 g/8 ml) seems like the ideal combination with maximal BMG adhesion capacity of the membrane. Particle distribution of BMG showed that 3/4 of the particles ranged between 300–1000 µ, the remnant 1/4 was smaller than 300 µ. The whole F-PRF membrane and its parts were compared with conventional A-PRF membrane concerning their resistance against proteolytic digestion. The F-PRF was superior to A-PRF, which dissolved within 4–5 days, while F-PRF was destroyed only after 11 days, so this provides a better chance for local bone morphogenesis. The F-PRF pieces had similar resistance to the whole intact one, so they can be ideal for surgical procedures without risk of fast disintegration.
Collapse
|
5
|
A novel, multi-level approach to assess allograft incorporation in revision total hip arthroplasty. Sci Rep 2020; 10:15226. [PMID: 32939007 PMCID: PMC7494851 DOI: 10.1038/s41598-020-72257-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Accepted: 08/20/2020] [Indexed: 11/09/2022] Open
Abstract
The successful use of allografts in reconstructive orthopedic surgery, including revision total hip arthroplasty (THA), has been outlined repeatedly. Nonetheless, as previous studies were primarily based on clinical follow-ups, we aimed to create an algorithm that accurately determines the extent of allograft incorporation in the acetabulum and femur using a suite of high-resolution imaging techniques. This study is based on a large patient database including > 4,500 patient data with previous revision THA and simultaneous use of allografts. While the database was continuously matched with the deceased individuals at the local forensic medicine department, complete hips were retrieved in case of a positive match. A positive match was achieved for n = 46 hips at a mean follow-up of 11.8 ± 5.1 years. Comprehensive imaging included contact radiography, high-resolution computed tomography (HR-pQCT), undecalcified histology of ground sections and quantitative backscattered electron imaging (qBEI). We here define a histomorphometric toolkit of parameters to precisely characterize the incorporation of structural (bulk) and morselized (chip) allografts in the acetabulum (n = 38) and femur (n = 8), including the defect area and interface length, microstructural and cellular bone turnover parameters as well as overlap and fibrosis thickness. This collection of samples, through its unique study design and precise definition of incorporation parameters, will provide the scientific community with a valuable source for further in-depth investigation of allograft incorporation and, beyond that, the regenerative potential of this osteoconductive scaffold.
Collapse
|
6
|
Lin C, Zhang N, Waldorff EI, Punsalan P, Wang D, Semler E, Ryaby JT, Yoo J, Johnstone B. Comparing cellular bone matrices for posterolateral spinal fusion in a rat model. JOR Spine 2020; 3:e1084. [PMID: 32613160 PMCID: PMC7323463 DOI: 10.1002/jsp2.1084] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 02/28/2020] [Accepted: 02/29/2020] [Indexed: 01/01/2023] Open
Abstract
INTRODUCTION Cellular bone matrices (CBM) are allograft products that provide three components essential to new bone formation: an osteoconductive scaffold, extracellular growth factors for cell proliferation and differentiation, and viable cells with osteogenic potential. This is an emerging technology being applied to augment spinal fusion procedures as an alternative to autografts. METHODS We aim to compare the ability of six commercially-available human CBMs (Trinity ELITE®, ViviGen®, Cellentra®, Osteocel® Pro, Bio4® and Map3®) to form a stable spinal fusion using an athymic rat model of posterolateral fusion. Iliac crest bone from syngeneic rats was used as a control to approximate the human gold standard. The allografts were implanted at L4-5 according to vendor specifications in male athymic rats, with 15 rats in each group. MicroCT scans were performed at 48 hours and 6 weeks post-implantation. The rats were euthanized 6 weeks after surgery and the lumbar spines were harvested for X-ray, manual palpation and histology analysis by blinded reviewers. RESULTS By manual palpation, five of 15 rats of the syngeneic bone group were fused at 6 weeks. While Trinity ELITE had eight of 15 and Cellentra 11 of 15 rats with stable fusion, only 2 of 15 of ViviGen-implanted spines were fused and zero of 15 of the Osteocel Pro, Bio4 and Map3 produced stable fusion. MicroCT analysis indicated that total bone volume increased from day 0 to week 6 for all groups except syngeneic bone group. Trinity ELITE (65%) and Cellentra (73%) had significantly greater bone volume increases over all other implants, which was consistent with the histological analysis. CONCLUSION Trinity ELITE and Cellentra were significantly better than other implants at forming new bone and achieving spinal fusion in this rat model at week 6. These results suggest that there may be large differences in the ability of different CBMs to elicit a successful fusion in the posterolateral spine.
Collapse
Affiliation(s)
- Cliff Lin
- Department of Orthopaedics and RehabilitationOregon Health & Science UniversityPortlandOregonUSA
| | | | | | - Paolo Punsalan
- Department of Orthopaedics and RehabilitationOregon Health & Science UniversityPortlandOregonUSA
| | | | | | | | - Jung Yoo
- Department of Orthopaedics and RehabilitationOregon Health & Science UniversityPortlandOregonUSA
| | - Brian Johnstone
- Department of Orthopaedics and RehabilitationOregon Health & Science UniversityPortlandOregonUSA
| |
Collapse
|
7
|
Leiblein M, Koch E, Winkenbach A, Schaible A, Nau C, Büchner H, Schröder K, Marzi I, Henrich D. Size matters: Effect of granule size of the bone graft substitute (Herafill®) on bone healing using Masquelet's induced membrane in a critical size defect model in the rat's femur. J Biomed Mater Res B Appl Biomater 2019; 108:1469-1482. [PMID: 31721435 DOI: 10.1002/jbm.b.34495] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Revised: 08/19/2019] [Accepted: 09/16/2019] [Indexed: 12/21/2022]
Abstract
The Masquelet technique for the treatment of large bone defects is a two-stage procedure based on an induced membrane. The size of a scaffold is reported to be a critical factor for bone healing response. We therefore aimed to investigate the influence of the granule size of a bone graft substitute on bone marrow derived mononuclear cells (BMC) supported bone healing in combination with the induced membrane. We compared three different sizes of Herafill® granules (Heraeus Medical GmbH, Wehrheim) with or without BMC in vivo in a rat femoral critical size defect. A 10 mm defect was made in 126 rats and a membrane induced by a PMMA-spacer. After 3 weeks, the spacer was taken out and membrane filled with different granule sizes. After 8 weeks femurs were taken for radiological, biomechanical, histological, and immunohistochemical analysis. Further, whole blood of the rat was incubated with granules and expression of 29 peptide mediators was assessed. Smallest granules showed significantly improved bone healing compared to larger granules, which however did not lead to an increased biomechanical stability in the defect zone. Small granules lead to an increased accumulation of macrophages in situ which could be assigned to the inflammatory subtype M1 by majority. Increased release of chemotactic respectively proangiogenic active factors in vitro compared to syngenic bone and beta-TCP was observed. Granule size of the bone graft substitute Herafill® has significant impact on bone healing of a critical size defect in combination with Masquelet's technique in terms of bone formation and inflammatory potential.
Collapse
Affiliation(s)
- Maximilian Leiblein
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Klinikum der Johann Wolfgang Goethe-Universität, Frankfurt am Main, Germany
| | - Elias Koch
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Klinikum der Johann Wolfgang Goethe-Universität, Frankfurt am Main, Germany
| | - Andreas Winkenbach
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Klinikum der Johann Wolfgang Goethe-Universität, Frankfurt am Main, Germany
| | - Alexander Schaible
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Klinikum der Johann Wolfgang Goethe-Universität, Frankfurt am Main, Germany
| | - Christoph Nau
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Klinikum der Johann Wolfgang Goethe-Universität, Frankfurt am Main, Germany
| | | | - Katrin Schröder
- Vascular Research Center, University of Frankfurt, Frankfurt am Main, Germany
| | - Ingo Marzi
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Klinikum der Johann Wolfgang Goethe-Universität, Frankfurt am Main, Germany
| | - Dirk Henrich
- Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Klinikum der Johann Wolfgang Goethe-Universität, Frankfurt am Main, Germany
| |
Collapse
|
8
|
Biologic treatment options for the hip: A narrative review. CURRENT ORTHOPAEDIC PRACTICE 2019. [DOI: 10.1097/bco.0000000000000814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Dilogo IH, Phedy P, Kholinne E, Djaja YP, Fiolin J, Kusnadi Y, Yulisa ND. Autologous mesenchymal stem cell implantation, hydroxyapatite, bone morphogenetic protein-2, and internal fixation for treating critical-sized defects: a translational study. INTERNATIONAL ORTHOPAEDICS 2019; 43:1509-1519. [PMID: 30747273 PMCID: PMC6525135 DOI: 10.1007/s00264-019-04307-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Accepted: 01/27/2019] [Indexed: 01/10/2023]
Abstract
INTRODUCTION Critical-sized defect (CSD) is one of the most challenging cases for orthopaedic surgeons. We aim to explore the therapeutic potential of the combination of bone marrow-derived mesenchymal stem cells (BM-MSCs), hydroxyapatite (HA) granules, bone morphogenetic protein-2 (BMP-2), and internal fixation for treating CSDs. METHODS This was a translational study performed during the period of January 2012 to 2016. Subjects were patients diagnosed with CSDs who had previously failed surgical attempts. They were treated with the combination of autologous BM-MSCs, HA granules, BMP-2, and mechanical stabilization. Post-operative pain level, functional outcome, defect volume, and radiological healing were evaluated after a minimum follow-up of 12 months. RESULTS A total of six subjects were recruited in this study. The pain was significantly reduced in all cases; with the decrease of mean preoperative visual analog scale (VAS) from 4 ± 2.2 to 0 after six month follow-up. Clinical functional outcome percentage increased significantly from 25 ± 13.7 to 70.79 ± 19.5. Radiological healing assessment using Tiedemann score also showed an increase from 0.16 ± 0.4 to 8 ± 3 at one year follow-up. No immunologic nor neoplastic side effects were found. CONCLUSIONS The combination of autologous BM-MSCs, HA granules, and BMP-2 is safe and remains to be a good option for the definitive treatment for CSD with previous failed surgical attempts. Further studies with a larger sample size are required to be done.
Collapse
Affiliation(s)
- Ismail Hadisoebroto Dilogo
- Department of Orthopaedics and Traumatology, Cipto Mangunkusumo Hospital, Faculty of Medicine Universitas Indonesia, Jakarta, Indonesia.
- Stem Cells Medical Technology Integrated Service Unit, Cipto Mangunkusumo Hospital, Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia.
- Stem Cells and Tissue Engineering Research Cluster, Indonesian Medical Education and Research Institute (IMERI), Faculty of Medicine Universitas Indonesia, Jakarta, Indonesia.
| | - Phedy Phedy
- Department of Orthopaedics and Traumatology, Fatmawati General Hospital, Jakarta, Indonesia
| | - Erica Kholinne
- Department of Orthopaedics and Traumatology, St. Carolus Hospital, Jakarta, Indonesia
| | - Yoshi Pratama Djaja
- Department of Orthopaedics and Traumatology, Fatmawati General Hospital, Jakarta, Indonesia
| | - Jessica Fiolin
- Department of Orthopaedics and Traumatology, Cipto Mangunkusumo Hospital, Faculty of Medicine Universitas Indonesia, Jakarta, Indonesia
| | - Yuyus Kusnadi
- Laboratory of Regenerative and Cellular Therapy (ReGeniC), Bifarma Adiluhung Ltd., Jakarta, Indonesia
| | - Nyimas Diana Yulisa
- Department of Radiology, Cipto Mangunkusumo Hospital, Faculty of Medicine Universitas Indonesia, Jakarta, Indonesia
| |
Collapse
|
10
|
Abstract
Midfoot Charcot joints are complex problems that are most commonly seen in patients with peripheral neuropathy secondary to diabetes. The goal of management is to prevent pedal collapse, which can lead to ulceration; infection; and in some cases, amputation. Principles of surgical management should be centered on respecting the soft tissue, obtaining correction, maintaining correction, and supplementing with orthobiologics to achieve healing. The authors present strategies, case examples, and tips and tricks to treat this complex condition with external and internal fixation.
Collapse
Affiliation(s)
- Noman A Siddiqui
- International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD 21215, USA.
| | - Guido A LaPorta
- Geisinger CMC, 1800 Mulberry St, Scranton, PA 18510, USA; Our Lady of Lourdes Memorial Hospital, 169 Riverside Dr, Binghamton, NY 13905, USA
| |
Collapse
|
11
|
Rolvien T, Barbeck M, Wenisch S, Amling M, Krause M. Cellular Mechanisms Responsible for Success and Failure of Bone Substitute Materials. Int J Mol Sci 2018; 19:E2893. [PMID: 30249051 PMCID: PMC6213546 DOI: 10.3390/ijms19102893] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Revised: 09/17/2018] [Accepted: 09/20/2018] [Indexed: 12/13/2022] Open
Abstract
Bone grafts, i.e., autologous, allogeneic or synthetic bone substitute materials play an increasing role in reconstructive orthopedic surgery. While the indications and materials differ, it is important to understand the cellular mechanisms regarding their integration and remodeling, which are discussed in this review article. Osteoconductivity describes the new bone growth on the graft, while osteoinductivity represents the differentiation of undifferentiated cells into bone forming osteoblasts. The best case is that both mechanisms are accompanied by osteogenesis, i.e., bone modeling and remodeling of the graft material. Graft incorporation is mediated by a number of molecular pathways that signal the differentiation and activity of osteoblasts and osteoclasts (e.g., parathyroid hormone (PTH) and receptor activator of nuclear factor κβ ligand (RANKL), respectively). Direct contact of the graft and host bone as well as the presence of a mechanical load are a prerequisite for the successful function of bone grafts. Interestingly, while bone substitutes show good to excellent clinical outcomes, their histological incorporation has certain limits that are not yet completely understood. For instance, clinical studies have shown contrasting results regarding the complete or incomplete resorption and remodeling of allografts and synthetic grafts. In this context, a foreign body response can lead to complete material degradation via phagocytosis, however it may also cause a fibrotic reaction to the bone substitute. Finally, the success of bone graft incorporation is also limited by other factors, including the bone remodeling capacities of the host, the material itself (e.g., inadequate resorption, toxicity) and the surgical technique or preparation of the graft.
Collapse
Affiliation(s)
- Tim Rolvien
- Department of Orthopedics, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany.
| | - Mike Barbeck
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany.
| | - Sabine Wenisch
- Institute of Veterinary Anatomy, Histology and Embryology, Justus Liebig University of Giessen, 35385 Giessen, Germany.
| | - Michael Amling
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, 22529 Hamburg, Germany.
| | - Matthias Krause
- Department of Trauma, Hand and Reconstructive Surgery, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany.
| |
Collapse
|
12
|
Butscheidt S, Moritz M, Gehrke T, Püschel K, Amling M, Hahn M, Rolvien T. Incorporation and Remodeling of Structural Allografts in Acetabular Reconstruction: Multiscale, Micro-Morphological Analysis of 13 Pelvic Explants. J Bone Joint Surg Am 2018; 100:1406-1415. [PMID: 30106822 PMCID: PMC6133218 DOI: 10.2106/jbjs.17.01636] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Total hip arthroplasty (THA) is frequently accompanied by acetabular bone loss, which constitutes a major challenge in revision procedures. Structural allografts can be implanted to restore a stable osseous foundation for the acetabular prosthesis. As previous studies were limited to clinical data or included very few cases, the extent to which the graft bone is incorporated over time has remained unclear. METHODS Thirteen acetabula were retrieved post mortem, and the incorporation properties of the bone allografts were analyzed using a hierarchical approach of imaging techniques including contact radiography, high-resolution peripheral quantitative computed tomography (HR-pQCT), histological analysis of undecalcified specimens, and quantitative backscattered electron imaging (qBEI). The distance between the current allograft bone and host bone borders (i.e., current overlap) as well as the distance between the original allograft bone and host bone borders (i.e., total ingrowth) were assessed. RESULTS In 10 of 13 cases, the complete interface (100%) was characterized by direct contact and additional overlap of the allograft bone and host bone, while the remaining 3 cases demonstrated direct contact along 25% to 80% of the interface. The allograft bone showed an intact trabecular structure and significantly higher mineralization compared with the host bone. The mean current overlap (and standard deviation) was 2.3 ± 1.0 mm, with a maximum of 5.3 ± 2.4 mm. Importantly, the total ingrowth reached much further, to a mean of 7.2 ± 2.3 mm (maximum, 10.5 ± 4.0 mm). Neither the time that the allograft was in situ nor the degree of contact between the host and allograft bone correlated with the current overlap and the time in situ did not correlate with total ingrowth. CONCLUSIONS This study showed bone remodeling with subsequent interconnection of the host and allograft bone along the majority of the interface, leading to adequate incorporation of the allograft. The lack of complete incorporation of the graft did not lead to graft collapse up to 22 years after revision surgery. CLINICAL RELEVANCE Our study provides the first systematic multiscale evaluation of successfully implanted structural allografts and forms the scientific basis for their clinical use in revision THA.
Collapse
Affiliation(s)
- Sebastian Butscheidt
- Departments of Osteology and Biomechanics (S.B., M.M., M.A., M.H., and T.R.), Legal Medicine (K.P.), and Orthopaedic Surgery (T.R.), University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Menard Moritz
- Departments of Osteology and Biomechanics (S.B., M.M., M.A., M.H., and T.R.), Legal Medicine (K.P.), and Orthopaedic Surgery (T.R.), University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | | | - Klaus Püschel
- Departments of Osteology and Biomechanics (S.B., M.M., M.A., M.H., and T.R.), Legal Medicine (K.P.), and Orthopaedic Surgery (T.R.), University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael Amling
- Departments of Osteology and Biomechanics (S.B., M.M., M.A., M.H., and T.R.), Legal Medicine (K.P.), and Orthopaedic Surgery (T.R.), University Medical Center Hamburg-Eppendorf, Hamburg, Germany,E-mail address for M. Amling:
| | - Michael Hahn
- Departments of Osteology and Biomechanics (S.B., M.M., M.A., M.H., and T.R.), Legal Medicine (K.P.), and Orthopaedic Surgery (T.R.), University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Tim Rolvien
- Departments of Osteology and Biomechanics (S.B., M.M., M.A., M.H., and T.R.), Legal Medicine (K.P.), and Orthopaedic Surgery (T.R.), University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
13
|
Tally WC, Temple HT, Subhawong TY, Ganey T. Transforaminal Lumbar Interbody Fusion With Viable Allograft: 75 Consecutive Cases at 12-Month Follow-up. Int J Spine Surg 2018; 12:76-84. [PMID: 30280087 DOI: 10.14444/5013] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Background When conservative treatments fail to alleviate the discomfort of abnormal motion, spinal fusion has been shown to provide symptomatic treatment for spinal instability, stenosis, spondylolisthesis, and symptomatic degenerative disc disease. The trend and rates of fusion over the past few years have been dramatic in the United States. Accompanying that higher incidence has been the shifting from traditional open surgery to minimally invasive techniques to reduce scar tissue formation, extent of muscle stripping, and muscle retraction which all have been shown to adversely affect outcomes. Other reasons supporting the widespread transition to minimally invasive surgical (MIS) techniques include decreased postoperative pain, decreased intraoperative blood loss, shorter postoperative hospital stay, faster return to normal activity, and reduced reoperation rates. Spinal fusion procedures rely on a bony fusion substrate in addition to fixation hardware. While available grafting options include autogenous, allogeneic, and synthetic materials, recent interest in viable allograft material with living cells has drawn attention and attraction for incorporating a biologic basis for regenerative consideration. A recent viable allograft, complete with cellular and designated bone carrier (VIA Graft, Vivex Biomedical, Marietta, Georgia) has been developed. This study represents a retrospective review of a single-practice, single-surgeon evaluation of the product in 75 consecutive patients for fusion by computed tomography (CT) and radiographic evaluation at 12 months in conjunction with a MIS approach. Viable allograft was used to fill the peri-implant space, and central implant lumen was filled with a cancellous bone sponge soaked in perivertebral bone marrow. Posterolateral supplementation was attained with beta-tricalcium phosphate as a bulking agent. Methods A retrospective review identified patients treated for both primary and revision surgery who received VIA Graft cellular bone matrix material in minimally invasive interbody fusion (MIS-TLIF) with a minimum of 12-month follow up. The patient diagnoses included radiculopathy in all instances and varied collateral indications such as foraminal collapse, recurrent disc herniation, and spondylolisthesis to which pain and morbidity had been unresolved by conservative treatment. Adverse events including infection, revisions, and evidence of immune response were evaluated and patient comorbidities defined for the entire population of patients. Patient fusion status was assessed using thin slice CT by 2 independent radiologists separate from the surgeon. There were 75 consecutive adult patients with degenerative conditions of the lumbar spine who underwent MIS-TLIF surgery of which 40 (53%) were male and 35 (47%) were female. Mean age, height, and weight were 58 years, 170.18 cm (67 in), and 88.45 kg (195 lbs), respectively. The mean body mass index was 30. There were 16 patients (21%) who smoked and 12 (16%) with a history of diabetes. Independent blinded review of fusion was obtained by a board certified musculoskeletal radiologist and an experienced board certified orthopaedic surgeon to assess patient fusion status. Spinal segments were deemed fused if 12-month CT scans demonstrated evidence of bridging bone at the fusion site without observed motion on flexion-extension radiographs. Findings such as osteolysis around the implant or pedicle screws, extensive endplate cystic changes, or linear defects parallel to the endplates through intradiscal new bone formation were interpreted as signs of pseudarthrosis. Interobserver and intraobserver error and κ assessments were analyzed to assure agreement in the CT outcomes assessment where interpretation of κ were as follows: <0.00 = poor agreement, 0.00-0.20 = slight agreement, 0.21-0.40 = fair agreement, 0.41-0.60 = moderate agreement, 0.61-0.80 = substantial agreement, and 0.81-1.00 = almost perfect agreement. Differences were resolved by consensus amongst the observers. Results In total, 96% of the 75 patients with a total of 85 levels (96.5% of levels treated) achieved a fusion at 12 months. There were no perioperative or latent complications and no transfusions in all 75 patients. Conclusions In this population, 96% of the patients treated achieved the surgical objective in 96.5% of the levels treated. Level of Evidence IV. Clinical Relevance The high rate of fusion, the lack of secondary morbidity with autologous bone harvest, and the clinical success account for the benefits of viable allograft matrix for MIS-TLIF use.
Collapse
Affiliation(s)
- William C Tally
- GA Regents University/Medical College of Georgia, Athens Campus; Athens Orthopedic Clinic, Athens, Georgia
| | | | | | | |
Collapse
|
14
|
Watts V GJ, Zoga AC, Abraham JA. Posttreatment Imaging in Orthopedic Oncology. Semin Roentgenol 2017; 52:291-300. [PMID: 28965548 DOI: 10.1053/j.ro.2017.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- George J Watts V
- Department of Radiology, Musculoskeletal Imaging and Intervention, Thomas Jefferson University, Philadelphia, PA
| | - Adam C Zoga
- Department of Radiology, Musculoskeletal Imaging and Intervention, Thomas Jefferson University, Philadelphia, PA.
| | - John A Abraham
- Department of Orthopaedic Surgery, Musculoskeletal Oncology Center, Thomas Jefferson University, Philadelphia, PA; Orthopaedic Oncology Surgery, Rothman Institute, Philadelphia, PA
| |
Collapse
|
15
|
Demetter RS, Calahan BG, Mealey BL. Histologic Evaluation of Wound Healing After Ridge Preservation With Cortical, Cancellous, and Combined Cortico-Cancellous Freeze-Dried Bone Allograft: A Randomized Controlled Clinical Trial. J Periodontol 2017; 88:860-868. [PMID: 28452622 DOI: 10.1902/jop.2017.170155] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
BACKGROUND Cortical and cancellous mineralized freeze-dried bone allografts (FDBA) are available for use in alveolar ridge preservation after tooth extraction. There are currently no data regarding use of a combination 50%/50% cortico-cancellous FDBA compared with a 100% cortical or 100% cancellous FDBA in ridge preservation. The primary objective of this study is to dimensionally and histologically evaluate healing after ridge preservation in non-molar sites using 50%/50% cortico-cancellous FDBA versus 100% cortical and 100% cancellous FDBA. METHODS Sixty-six patients requiring extraction of a non-molar tooth were enrolled and randomized into three groups to receive ridge preservation with the following: 1) 100% cortical FDBA; 2) 100% cancellous FDBA; or 3) 50%/50% cortico-cancellous FDBA. After 18 to 20 weeks of healing, a biopsy was harvested, and an implant was placed. The alveolar ridge was measured pre- and postoperatively to evaluate change in ridge height and width. Percentages of vital bone, residual graft, and connective tissue (CT)/other were determined via histomorphometric analysis. RESULTS Histomorphometric analysis revealed no significant differences among groups regarding percentage of vital bone or CT/other. The 100% cortical FDBA group had significantly greater residual graft material (P = 0.04). Dimensional analysis revealed no significant between-group differences in any parameter measured. CONCLUSION To the best knowledge of the authors, this study offers the first histologic evidence demonstrating no significant difference in vital bone formation or dimensional changes among 50%/50% cortico-cancellous FDBA, 100% cortical FDBA, and 100% cancellous FDBA when used in ridge preservation of non-molar tooth sites.
Collapse
Affiliation(s)
- Randy S Demetter
- Department of Periodontics, University of Texas Health Science Center San Antonio, San Antonio, TX
| | - Blaine G Calahan
- Department of Periodontics, University of Texas Health Science Center San Antonio, San Antonio, TX
| | - Brian L Mealey
- Department of Periodontics, University of Texas Health Science Center San Antonio, San Antonio, TX
| |
Collapse
|
16
|
Abstract
Many allogeneic biologic materials, by themselves or in combination with cells or cell products, may be transformative in healing or regeneration of musculoskeletal bone and soft tissues. By reconfiguring the size, shape, and methods of tissue preparation to improve deliverability and storage, unique iterations of traditional tissue scaffolds have emerged. These new iterations, combined with new cell technologies, have shaped an exciting platform of regenerative products that are effective and provide a bridge to newer and better methods of providing care for orthopedic foot and ankle patients.
Collapse
|
17
|
|
18
|
Harmata AJ, Uppuganti S, Granke M, Guelcher SA, Nyman JS. Compressive fatigue and fracture toughness behavior of injectable, settable bone cements. J Mech Behav Biomed Mater 2015; 51:345-55. [PMID: 26282077 DOI: 10.1016/j.jmbbm.2015.07.027] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Revised: 07/23/2015] [Accepted: 07/27/2015] [Indexed: 01/09/2023]
Abstract
Bone grafts used to repair weight-bearing tibial plateau fractures often experience cyclic loading, and there is a need for bone graft substitutes that prevent failure of fixation and subsequent morbidity. However, the specific mechanical properties required for resorbable grafts to optimize structural compatibility with native bone have yet to be established. While quasi-static tests are utilized to assess weight-bearing ability, compressive strength alone is a poor indicator of in vivo performance. In the present study, we investigated the effects of interfacial bonding on material properties under conditions that re-capitulate the cyclic loading associated with weight-bearing fractures. Dynamic compressive fatigue properties of polyurethane (PUR) composites made with either unmodified (U-) or polycaprolactone surface-modified (PCL-) 45S5 bioactive glass (BG) particles were compared to a commercially available calcium sulfate and phosphate-based (CaS/P) bone cement at physiologically relevant stresses (5-30 MPa). Fatigue resistance of PCL-BG/polymer composite was superior to that of the U-BG/polymer composite and the CaS/P cement at higher stress levels for each of the fatigue failure criteria, related to modulus, creep, and maximum displacement, and was comparable to human trabecular bone. Steady state creep and damage accumulation occurred during the fatigue life of the PCL-BG/polymer and CaS/P cement, whereas creep of U-BG/polymer primarily occurred at a low number of loading cycles. From crack propagation testing, fracture toughness or resistance to crack growth was significantly higher for the PCL-BG composite than for the other materials. Finally, the fatigue and fracture toughness properties were intermediate between those of trabecular and cortical bone. These findings highlight the potential of PCL-BG/polyurethane composites as weight-bearing bone grafts.
Collapse
Affiliation(s)
- Andrew J Harmata
- Department of Chemical and Biomolecular Engineering, Vanderbilt University, Nashville, TN, USA; Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA.
| | - Sasidhar Uppuganti
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, TN, USA.
| | - Mathilde Granke
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, TN, USA.
| | - Scott A Guelcher
- Department of Chemical and Biomolecular Engineering, Vanderbilt University, Nashville, TN, USA; Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
| | - Jeffry S Nyman
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA; Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212, USA.
| |
Collapse
|
19
|
Brooks AE, Brooks BD, Davidoff SN, Hogrebe PC, Fisher MA, Grainger DW. Polymer-controlled release of tobramycin from bone graft void filler. Drug Deliv Transl Res 2015; 3:518-30. [PMID: 25786372 DOI: 10.1007/s13346-013-0155-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Despite clinical, material, and pharmaceutical advances, infection remains a major obstacle in total joint revision surgery. Successful solutions must extend beyond bulk biomaterial and device modifications, integrating locally delivered pharmaceuticals and physiological cues at the implant site, or within large bone defects with prominent avascular spaces. One approach involves coating clinically familiar allograft bone with an antibiotic-releasing rate-controlling polymer membrane for use as a matrix for local drug release in bone. The kinetics of drug release from this system can be tailored via alterations in the substrate or the polymeric coating. Drug-loaded polycaprolactone coating releases bioactive tobramycin from both cadaveric-sourced cancellous allograft fragments and synthetic hybrid coralline ceramic bone graft fragments with similar kinetics over a clinically relevant 6-week timeframe. However, micron-sized allograft particulate provides extended bioactive tobramycin release. Addition of porogen polyethylene glycol to the polymer coating formulation changes tobramycin release kinetics without significant impact on released antibiotic bioactivity. Incorporation of oil-microencapsulated tobramycin into the polymer coating did not significantly modify tobramycin release kinetics. In addition to releasing inhibitory concentrations of tobramycin, antibiotic-loaded allograft bone provides recognized beneficial osteoconductive potential, attractive for decreasing orthopedic surgical infections with improved filling of dead space and new bone formation.
Collapse
Affiliation(s)
- Amanda E Brooks
- Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT, 84112-5820, USA,
| | | | | | | | | | | |
Collapse
|
20
|
Zbojniewicz AM, Sorger JI. Posttreatment imaging of pediatric musculoskeletal tumors. Radiographics 2015; 34:724-40. [PMID: 24819791 DOI: 10.1148/rg.342135069] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Pediatric patients who are diagnosed with musculoskeletal tumors often require serial imaging both during and after treatment. Although many of the treatments used in adults overlap with those used in children and adolescents, the growing skeleton presents specific challenges that require a unique approach. Surgical treatment of benign osseous lesions typically requires only curettage and bone grafting, whereas that of osseous malignancies generally consists of wide excision and limb salvage, with either endoprosthetic or biologic reconstruction. Current conventional endoprostheses consist of modular components that allow intraoperative customization; however, if there is great potential for future growth, an expandable endoprosthesis may be required. Biologic reconstruction may consist of an allograft and/or autograft and, in some circumstances, can spare the growth plates in a child, thereby allowing normal growth. Expected posttreatment imaging findings in soft-tissue tumors may include muscle flaps and postoperative fluid collections. Medical treatment, including radiation therapy and chemotherapy, can have predictable imaging manifestations, including signal alterations in bone marrow, muscle, and subcutaneous fat. Finally, treatment complications may manifest with clinical symptoms and include infection or mechanical failure, although other complications such as local tumor recurrence may go clinically undetected until surveillance imaging. Familiarity with the expected posttreatment imaging findings in pediatric patients with musculoskeletal tumors can aid in the detection of complications.
Collapse
Affiliation(s)
- Andrew M Zbojniewicz
- From the Division of Pediatric Radiology (A.M.Z.) and Department of Orthopedic Surgery (J.I.S.), Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, MLC 5031, Cincinnati, OH 45229
| | | |
Collapse
|
21
|
The Extraction and Measurement of Bone Morphogenetic Protein 7 From Bovine Cortical Bone as a Function of Particle Size. J Craniofac Surg 2015; 26:296-9. [DOI: 10.1097/scs.0000000000001301] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
22
|
Christou C, Oliver RA, Yu Y, Walsh WR. The Masquelet technique for membrane induction and the healing of ovine critical sized segmental defects. PLoS One 2014; 9:e114122. [PMID: 25461340 PMCID: PMC4252083 DOI: 10.1371/journal.pone.0114122] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2014] [Accepted: 11/05/2014] [Indexed: 01/26/2023] Open
Abstract
The healing of critical sized segmental defects is an ongoing clinical problem. No method has achieved pre-eminence. The Masquelet technique is a relatively new innovation involving the induction of a fibrous tissue membrane around the bone defect site taking advantage of the body's foreign body reaction to the presence of a polymethylmethacrylate (PMMA) spacer. The aim of this study was to investigate the properties and characteristics of this induced membrane and its effectiveness when used in conjunction with allograft or an allograft/autograft mix as filler materials in an ovine critical sized defect model. The resultant induced membrane was found to be effective in containing the graft materials in situ. It was demonstrated to be an organised pseudosynovial membrane which expressed bone morphogenic protein 2 (BMP2), transforming growth factor-beta (TGFβ), vascular endothelial growth factor (VEGF), von Willerbrand factor (vWF), interleukin 6 (IL-6) and interleukin 8 (IL-8). While more new bone growth was evident in the test groups compared to the controls animals at 12 weeks, the volumes were not statistically different and no defects were fully bridged. Of the two graft material groups, the allograft/autograft mix was shown to have a more rapid graft resorption rate than the allograft only group. While the Masquelet technique proved effective in producing a membrane to enclose graft materials, its ability to assist in the healing of critical sized segmental defects when compared to empty controls remained inconclusive.
Collapse
Affiliation(s)
- Chris Christou
- Surgical and Orthopaedic Research Laboratories, University of New South Wales Australia, Sydney, New South Wales, Australia
| | - Rema A. Oliver
- Surgical and Orthopaedic Research Laboratories, University of New South Wales Australia, Sydney, New South Wales, Australia
| | - Yan Yu
- Surgical and Orthopaedic Research Laboratories, University of New South Wales Australia, Sydney, New South Wales, Australia
| | - William R. Walsh
- Surgical and Orthopaedic Research Laboratories, University of New South Wales Australia, Sydney, New South Wales, Australia
| |
Collapse
|
23
|
Carpenter EM, Llamas C, Buck BE, Malinin TI. Induction of neural tissue markers by micronized human spinal cord implants. J Neurosci Res 2014; 93:495-503. [DOI: 10.1002/jnr.23505] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Revised: 09/23/2014] [Accepted: 09/24/2014] [Indexed: 11/11/2022]
Affiliation(s)
- Ellen M. Carpenter
- Department of Psychiatry and Biobehavioral Science; UCLA School of Medicine; Los Angeles California
| | - Carlos Llamas
- Department of Psychiatry and Biobehavioral Science; UCLA School of Medicine; Los Angeles California
| | - Billy E. Buck
- Tissue Bank and Department of Orthopaedics; University of Miami Miller School of Medicine; Miami Florida
| | - Theodore I. Malinin
- Tissue Bank and Department of Orthopaedics; University of Miami Miller School of Medicine; Miami Florida
| |
Collapse
|
24
|
Wang L, Barbieri D, Zhou H, de Bruijn JD, Bao C, Yuan H. Effect of particle size on osteoinductive potential of microstructured biphasic calcium phosphate ceramic. J Biomed Mater Res A 2014; 103:1919-29. [PMID: 25203625 DOI: 10.1002/jbm.a.35325] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2014] [Revised: 08/26/2014] [Accepted: 09/03/2014] [Indexed: 02/05/2023]
Abstract
Material factors such as chemistry, surface microstructure and geometry have shown their influence on osteoinduction of calcium phosphate ceramics. Hereby we report that osteoinduction of a micro-structured biphasic calcium phosphate ceramic (BCP) has a relation with the particle sizes. BCP particles with the size of 212-300 µm, 106-212 µm, 45-106 µm, and smaller than 45 µm were prepared and implanted in paraspinal muscle of dogs for 12 weeks. Histological evaluation of the explants showed abundant bone in all samples with particle size of 212-300 µm, 106-212 µm, and 45-106 µm, while no bone was seen in any sample having particle size smaller than 45 µm. Bone was formed as early as 3 weeks after implantation in implants having BCP particles bigger than 45 µm and the volume of the formed bone was similar among the implants with particles larger than 45 µm after 12 weeks implantation. The results herein show that a size limitation of microstructured calcium phosphate ceramic particles for osteoinduction. It is most likely that the particle size affect inductive bone formation via macroporous structures for body fluid infiltration, cell/tissue ingrowth and angiogenesis.
Collapse
Affiliation(s)
- Liao Wang
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China
| | | | | | | | | | | |
Collapse
|
25
|
Oporto V GH, Fuentes R, Borie E, del Sol M, Orsi IA, Engelke W. Radiographical and clinical evaluation of critical size defects in rabbit calvaria filled with allograft and autograft: a pilot study. Int J Clin Exp Med 2014; 7:1669-1675. [PMID: 25126163 PMCID: PMC4132127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2014] [Accepted: 06/23/2014] [Indexed: 06/03/2023]
Abstract
Regeneration of resorbed edentulous sites can be induced by bone grafts from the subject himself and/or by the use of biomaterials. At present, there has been an extensive search for biomaterials that are evaluated by artificially creating one or more critical defects. The aim of this work was to clinically and radiographically analyze bone formation by the use of some biomaterials in artificially created defects in the parietal bone of rabbits. Six rabbits were used, creating defects of 8 mm in diameter in parietal bones. One defect was maintained with coagulum only, and in others, freeze-dried bone allograft (FDBA), autologous bone, and a combination of autologous bone with FDBA respectively, were added. Animals were sacrificed at 15-90 days with 2 weeks interval each, and calvaria were analyzed macroscopically, measuring by digital caliper the lack of filling at the surface of defects, identifying limits at anteroposterior and coronal view, realizing a digital photograph register of their external surfaces. This was subsequently evaluated radiographically by occlusal film radiography used to quantify its density through software. In conclusion, autologous bone showed the best behavior, clinically as well as radiographically. However, FDBA is a good option as an alternative to autologous bone as its behavior was slightly lower over time. The combination of autologous bone and FDBA in the same defect showed results considerably inferior to grafts used separately. Low radiopacity and clear limits were observed through time for the control coagulum filled defect.
Collapse
Affiliation(s)
| | - Ramón Fuentes
- CIMOFIR Research Centre, Dental School, Universidad de La FronteraTemuco, Chile
| | - Eduardo Borie
- CIMOFIR Research Centre, Dental School, Universidad de La FronteraTemuco, Chile
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São PauloRibeirão Preto, SP, Brazil
| | - Mariano del Sol
- Department of Basic Sciences, Medicine School, Universidad de La FronteraTemuco, Chile
- Research Centre in Biomedical Sciences, Universidad Autónoma de ChileChile
| | - Iara Augusta Orsi
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São PauloRibeirão Preto, SP, Brazil
| | - Wilfried Engelke
- Dentistry Centre, Department of Maxillofacial Surgery, University of GöttingenGöttingen, Germany
| |
Collapse
|
26
|
Eskow AJ, Mealey BL. Evaluation of healing following tooth extraction with ridge preservation using cortical versus cancellous freeze-dried bone allograft. J Periodontol 2013; 85:514-24. [PMID: 23725026 DOI: 10.1902/jop.2013.130178] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
BACKGROUND The objective of this study is to compare histologic and clinical healing following tooth extraction and ridge preservation with either cortical or cancellous freeze-dried bone allograft (FDBA) in non-molar extraction sockets. METHODS Forty patients requiring implant placement were enrolled, with 20 patients randomly assigned to each group (cortical versus cancellous FDBA). All of the allograft materials were obtained from the same donor to control for variability between donors and processing. Patients returned after 17 to 21 weeks (average: 18.2 weeks), and a 2-mm-diameter core biopsy was obtained before implant placement. Histomorphometric analysis was performed to determine percentage of new bone formation, residual graft material, and non-mineralized connective tissue (CT)/other material. Clinical measurements of ridge dimensions were taken at the time of tooth extraction and again at implant placement. RESULTS There was no significant difference in new bone formation between the cortical and cancellous FDBA groups (P = 0.857). A significantly greater percentage of residual graft material was detected in the cortical FDBA group compared with the cancellous FDBA group (P = 0.019). A significantly greater percentage of non-mineralized CT/other material was found in the cancellous FDBA group compared with the cortical FDBA group (P = 0.040). The only significant clinical difference between groups was a greater loss of lingual ridge height in the cancellous group. CONCLUSIONS This is the first reported study to compare the histologic changes following tooth extraction with ridge preservation in humans using cortical versus cancellous FDBA. There were no differences in the percentage of new bone formation between the groups.
Collapse
Affiliation(s)
- Adam J Eskow
- Currently, Private Practice, Washington, DC; previously, Department of Periodontics, University of Texas Health Science Center at San Antonio, San Antonio, TX
| | | |
Collapse
|
27
|
Dumas JE, BrownBaer PB, Prieto EM, Guda T, Hale RG, Wenke JC, Guelcher SA. Injectable reactive biocomposites for bone healing in critical-size rabbit calvarial defects. Biomed Mater 2012; 7:024112. [DOI: 10.1088/1748-6041/7/2/024112] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
28
|
|
29
|
The influence of FDBA and autogenous bone particles on regeneration of calvaria defects in the rabbit: A pilot study. Ann Anat 2011; 193:412-7. [DOI: 10.1016/j.aanat.2011.06.003] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2011] [Revised: 04/27/2011] [Accepted: 06/06/2011] [Indexed: 11/21/2022]
|
30
|
Yoshii T, Dumas JE, Okawa A, Spengler DM, Guelcher SA. Synthesis, characterization of calcium phosphates/polyurethane composites for weight-bearing implants. J Biomed Mater Res B Appl Biomater 2011; 100:32-40. [DOI: 10.1002/jbm.b.31917] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2010] [Revised: 06/13/2011] [Accepted: 06/16/2011] [Indexed: 11/11/2022]
|
31
|
Dumas JE, Zienkiewicz K, Tanner SA, Prieto EM, Bhattacharyya S, Guelcher SA. Synthesis and Characterization of an Injectable Allograft Bone/Polymer Composite Bone Void Filler with Tunable Mechanical Properties. Tissue Eng Part A 2010; 16:2505-18. [DOI: 10.1089/ten.tea.2009.0672] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Jerald E. Dumas
- Department of Chemical and Biomolecular Engineering, Vanderbilt University, Nashville, Tennessee
- Center for Bone Biology, Vanderbilt University, Nashville, Tennessee
| | - Katarzyna Zienkiewicz
- Department of Chemical and Biomolecular Engineering, Vanderbilt University, Nashville, Tennessee
- Center for Bone Biology, Vanderbilt University, Nashville, Tennessee
| | - Shaun A. Tanner
- Department of Chemical and Biomolecular Engineering, Vanderbilt University, Nashville, Tennessee
- Center for Bone Biology, Vanderbilt University, Nashville, Tennessee
| | - Edna M. Prieto
- Department of Chemical and Biomolecular Engineering, Vanderbilt University, Nashville, Tennessee
- Center for Bone Biology, Vanderbilt University, Nashville, Tennessee
| | | | - Scott A. Guelcher
- Department of Chemical and Biomolecular Engineering, Vanderbilt University, Nashville, Tennessee
- Center for Bone Biology, Vanderbilt University, Nashville, Tennessee
| |
Collapse
|
32
|
Cancellous and Cortical Microparticulate Allograft for Dental Implantation: An Experimental Study in Non-Human Primates. IMPLANT DENT 2009; 18:420-7. [DOI: 10.1097/id.0b013e3181ad18d6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
33
|
Temple HT, Malinin TI. Microparticulate cortical allograft: an alternative to autograft in the treatment of osseous defects. Open Orthop J 2008; 2:91-6. [PMID: 19478936 PMCID: PMC2687117 DOI: 10.2174/1874325000802010091] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2008] [Revised: 04/18/2008] [Accepted: 04/29/2008] [Indexed: 11/23/2022] Open
Abstract
Benign bone tumors are commonly diagnosed and treated. Following tumor removal, the defect in the bone can be filled with auto- or allografts, (degradable) bone substitutes or non-degradable polymethylmethacrylate. The ideal substitute for this purpose should provide immediate structural support and readily incorporate into bone over a short period of time. Experimentally, microparticulate allograft has been shown to incorporate quickly in metaphyseal and metadiaphyseal cortico-cancellous defects in primates [1]. Using a combination of small allogeneic cortical graft particles (< 250 µm), bone defects were filled following intralesional excision in 97 consecutive patients with benign and low grade malignant tumors and tumor-like conditions of bone. The clinical results and rate of radiographic incorporation and osseous consolidation were recorded and analyzed. These patients underwent 104 procedures in which osseous defects were packed with microparticulate allograft. The follow-up was from 23 to 49 months. There were 94 (90.3%) closed defects and 10 (9.7%) open defects. The average size of the grafted defect was 42.8 cm3 (0.48 - 315.0 cm3). Internal fixation was used in 11 of the 104 procedures (10.6 %). Radiographically, incorporation was observed in 91% of patients and consolidation in 60%. There were eleven failures (10.6 %), eight (72 %) due to tumor recurrence. Seven of eight patients with tumor recurrence underwent a second resection and grafting procedure that resulted in allograft incorporation and defect healing. There were two deep infections requiring debridement with retention of the graft; both resolved with satisfactory healing. Both incorporation and consolidation were observed in over 90% of patients with a low rate of complications. The use of small-particle cortical allograft proved to be an effective alternative to autogenous bone graft in patients with metaphyseal and metadiaphyseal surgical bone defects.
Collapse
Affiliation(s)
- H Thomas Temple
- Tissue Bank, Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, Florida, USA
| | | |
Collapse
|