Liu Q, Guo X, Wang Z, Xu H, Huang W, Liu J, Wang Z, Yan F, Wu Z, Ding X. Computed Tomography-guided Percutaneous Lung Biopsy With Electromagnetic Navigation Compared With Conventional Approaches: An Open-label, Randomized Controlled Trial. J Thorac Imaging 2024; 39:247-254. [PMID: 37982518 DOI: 10.1097/rti.0000000000000763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2023]
Abstract
PURPOSE The purpose of this study was to assess the efficiency and safety of computed tomography (CT)-guided percutaneous biopsy of lung lesions with electromagnetic (EM) navigation and compare them with those of conventional approaches. MATERIALS AND METHODS Seventy-nine patients with lung or liver lesions who needed biopsies were enrolled in this trial. All patients were randomly assigned to the E group underwent CT-guided percutaneous biopsies with the EM navigation system or to the C group treated with conventional approaches. RESULTS In total, 27 patients with lung lesions were assigned to the E group, and 20 patients were assigned to the C group. The diagnostic success rate was 92.6% and 95% in both groups, respectively ( P >0.9999). The median number of needle repositions in the E group was less than that in the C group (2.0 vs. 2.5, P =0.03). The positioning success rate with 1 or 2 needle repositions for the E group was significantly higher than the C group (81.5% vs. 50%, P =0.03). The median accuracy of the puncture location in the E group was better than that in the C group (2.0 vs. 6.6 mm, P <0.0001). The total procedure time lengthened in the E group compared with the C group (30.5±1.6 vs. 18.3±1.7 min, P <0.0001), but the number of CT acquisitions was not significantly different ( P =0.08). There was no significant difference in complication incidence between the 2 groups ( P =0.44). CONCLUSION The EM navigation system is an effective and safe auxiliary tool for CT-guided percutaneous lung biopsy, but lengthen the procedure time. TRIAL REGISTRATION ChiCTR2100043361, registered February 9, 2021-retrospectively registered ( http://www.medresman.org.cn/uc/project/projectedit.aspx?proj=7591 ).
Collapse
Affiliation(s)
- Qin Liu
- Departments of Interventional Radiology
| | | | | | - Hao Xu
- Departments of Interventional Radiology
- Department of Vascular Surgery and Interventional Radiology, Suzhou DuShu Lake Hospital, Soochow University, Suzhou, China
| | - Wei Huang
- Departments of Interventional Radiology
| | | | | | - Fuhua Yan
- Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai
| | | | | |
Collapse
|
2
|
Frühling P, Stillström D, Holmquist F, Nilsson A, Freedman J. Change in tissue resistance after irreversible electroporation in liver tumors as an indicator of treatment success - A multi-center analysis with long term follow-up. EUROPEAN JOURNAL OF SURGICAL ONCOLOGY 2024; 50:108508. [PMID: 38950490 DOI: 10.1016/j.ejso.2024.108508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 06/03/2024] [Accepted: 06/22/2024] [Indexed: 07/03/2024]
Abstract
INTRODUCTION A nationwide multicenter study was performed to examine whether there is a correlation between decrease in tissue resistance and time to local tumor recurrence after irreversible electroporation (IRE) in patients with hepatocellular carcinoma (HCC) and colorectal cancer liver metastases (CRCLM). METHODS All patients treated with IRE for liver tumors in Sweden from 2011 until 2018 were included. Patient characteristics and recurrence patterns were obtained from medical records and radiological imaging. All procedural data from the IRE hardware at the three hospitals performing IRE were retrieved. The resistance during each pulse and the change during each treatment were calculated. The electrode pair with the smallest decrease in tissue resistance was used and compared with the time to LTP. RESULTS 149 patients with 206 tumors were treated. Exclusion due to missing and inaccurate data resulted in 124 patients with 170 tumors for the analyses. In a multivariable Cox regression model, a smaller decrease in tissue resistance and larger tumor size were associated with shorter time to local tumor recurrence for CRCLM, but not for HCC. CONCLUSION There was an association between a decrease in tissue resistance and time to local tumor recurrence for CRCLM. The decrease in resistance, in combination with a rise in current, may be the parameters the interventionist should use during IRE to decide if the treatment is successful.
Collapse
Affiliation(s)
- Petter Frühling
- Department of Surgical Sciences, Uppsala University, Uppsala Sweden.
| | - David Stillström
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
| | - Fredrik Holmquist
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
| | - Anders Nilsson
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
| | - Jacob Freedman
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
| |
Collapse
|
3
|
Uribe Rivera AK, Seeliger B, Goffin L, García-Vázquez A, Mutter D, Giménez ME. Robotic Assistance in Percutaneous Liver Ablation Therapies: A Systematic Review and Meta-Analysis. ANNALS OF SURGERY OPEN 2024; 5:e406. [PMID: 38911657 PMCID: PMC11191991 DOI: 10.1097/as9.0000000000000406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 02/19/2024] [Indexed: 06/25/2024] Open
Abstract
Objective The aim of this systematic review and meta-analysis is to identify current robotic assistance systems for percutaneous liver ablations, compare approaches, and determine how to achieve standardization of procedural concepts for optimized ablation outcomes. Background Image-guided surgical approaches are increasingly common. Assistance by navigation and robotic systems allows to optimize procedural accuracy, with the aim to consistently obtain adequate ablation volumes. Methods Several databases (PubMed/MEDLINE, ProQuest, Science Direct, Research Rabbit, and IEEE Xplore) were systematically searched for robotic preclinical and clinical percutaneous liver ablation studies, and relevant original manuscripts were included according to the Preferred Reporting items for Systematic Reviews and Meta-Analyses guidelines. The endpoints were the type of device, insertion technique (freehand or robotic), planning, execution, and confirmation of the procedure. A meta-analysis was performed, including comparative studies of freehand and robotic techniques in terms of radiation dose, accuracy, and Euclidean error. Results The inclusion criteria were met by 33/755 studies. There were 24 robotic devices reported for percutaneous liver surgery. The most used were the MAXIO robot (8/33; 24.2%), Zerobot, and AcuBot (each 2/33, 6.1%). The most common tracking system was optical (25/33, 75.8%). In the meta-analysis, the robotic approach was superior to the freehand technique in terms of individual radiation (0.5582, 95% confidence interval [CI] = 0.0167-1.0996, dose-length product range 79-2216 mGy.cm), accuracy (0.6260, 95% CI = 0.1423-1.1097), and Euclidean error (0.8189, 95% CI = -0.1020 to 1.7399). Conclusions Robotic assistance in percutaneous ablation for liver tumors achieves superior results and reduces errors compared with manual applicator insertion. Standardization of concepts and reporting is necessary and suggested to facilitate the comparison of the different parameters used to measure liver ablation results. The increasing use of image-guided surgery has encouraged robotic assistance for percutaneous liver ablations. This systematic review analyzed 33 studies and identified 24 robotic devices, with optical tracking prevailing. The meta-analysis favored robotic assessment, showing increased accuracy and reduced errors compared with freehand technique, emphasizing the need for conceptual standardization.
Collapse
Affiliation(s)
- Ana K Uribe Rivera
- From the IHU-Strasbourg, Institute of Image-Guided Surgery, Strasbourg, France
| | - Barbara Seeliger
- From the IHU-Strasbourg, Institute of Image-Guided Surgery, Strasbourg, France
- Department of Visceral and Digestive Surgery, University Hospitals of Strasbourg, Strasbourg, France
- IRCAD, Research Institute Against Digestive Cancer, Strasbourg, France
- ICube, UMR 7357 CNRS, INSERM U1328 RODIN, University of Strasbourg, Strasbourg, France
- Inserm U1110, Institute for Viral and Liver Diseases, Strasbourg. France
- Trustworthy AI Lab, Centre National de la Recherche Scientifique (CNRS), France
| | - Laurent Goffin
- ICube, UMR 7357 CNRS, INSERM U1328 RODIN, University of Strasbourg, Strasbourg, France
- Trustworthy AI Lab, Centre National de la Recherche Scientifique (CNRS), France
- Computational Surgery SAS, Schiltigheim, France
| | | | - Didier Mutter
- From the IHU-Strasbourg, Institute of Image-Guided Surgery, Strasbourg, France
- Department of Visceral and Digestive Surgery, University Hospitals of Strasbourg, Strasbourg, France
- IRCAD, Research Institute Against Digestive Cancer, Strasbourg, France
| | - Mariano E Giménez
- From the IHU-Strasbourg, Institute of Image-Guided Surgery, Strasbourg, France
- IRCAD, Research Institute Against Digestive Cancer, Strasbourg, France
- DAICIM Foundation (Training, Research and Clinical Activity in Minimally Invasive Surgery), Buenos Aires, Argentina
| |
Collapse
|
4
|
Chlorogiannis DD, Charalampopoulos G, Bale R, Odisio B, Wood BJ, Filippiadis DK. Innovations in Image-Guided Procedures: Unraveling Robot-Assisted Non-Hepatic Percutaneous Ablation. Semin Intervent Radiol 2024; 41:113-120. [PMID: 38993597 PMCID: PMC11236453 DOI: 10.1055/s-0044-1786724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/13/2024]
Abstract
Interventional oncology is routinely tasked with the feat of tumor characterization or destruction, via image-guided biopsy and tumor ablation, which may pose difficulties due to challenging-to-reach structures, target complexity, and proximity to critical structures. Such procedures carry a risk-to-benefit ratio along with measurable radiation exposure. To streamline the complexity and inherent variability of these interventions, various systems, including table-, floor-, gantry-, and patient-mounted (semi-) automatic robotic aiming devices, have been developed to decrease human error and interoperator and intraoperator outcome variability. Their implementation in clinical practice holds promise for enhancing lesion targeting, increasing accuracy and technical success rates, reducing procedure duration and radiation exposure, enhancing standardization of the field, and ultimately improving patient outcomes. This narrative review collates evidence regarding robotic tools and their implementation in interventional oncology, focusing on clinical efficacy and safety for nonhepatic malignancies.
Collapse
Affiliation(s)
| | - Georgios Charalampopoulos
- 2nd Department of Radiology, University General Hospital “ATTIKON,” Medical School, National and Kapodistrian University of Athens, Athens, Greece
| | - Reto Bale
- Department of Radiology, Interventional Oncology - Stereotaxy and Robotics, Medical University Innsbruck, Innsbruck, Austria
| | - Bruno Odisio
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Bradford J. Wood
- Interventional Radiology and Center for Interventional Oncology, NIH Clinical Center and National Cancer Institute, National Institutes of Health, Bethesda, Maryland
| | - Dimitrios K. Filippiadis
- 2nd Department of Radiology, University General Hospital “ATTIKON,” Medical School, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|
5
|
Graur A, Mercaldo ND, Simon J, Alici C, Saenger JA, Cahalane AM, Vazquez R, Fintelmann FJ. High-Frequency Jet Ventilation Versus Spontaneous Respiration for Percutaneous Cryoablation of Lung Tumors: Comparison of Adverse Events and Procedural Efficiency. AJR Am J Roentgenol 2024; 222:e2330557. [PMID: 38264999 DOI: 10.2214/ajr.23.30557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2024]
Abstract
BACKGROUND. High-frequency jet ventilation (HFJV) facilitates accurate probe placement in percutaneous ablation of lung tumors but may increase risk for adverse events, including systemic air embolism. OBJECTIVE. The purpose of this study was to compare major adverse events and procedural efficiency of percutaneous lung ablation with HFJV under general anesthesia to spontaneous respiration (SR) under moderate sedation. METHODS. This retrospective study included consecutive adults who underwent CT-guided percutaneous cryoablation of one or more lung tumors with HFJV or SR between January 1, 2017, and May 31, 2023. We compared major adverse events (Common Terminology Criteria for Adverse Events grade ≥ 3) within 30 days postprocedure and hospital length of stay (HLOS) of 2 days or more using logistic regression analysis. We compared procedure time, room time, CT guidance acquisition time, CT guidance radiation dose, total radiation dose, and pneumothorax using generalized estimating equations. RESULTS. Overall, 139 patients (85 women, 54 men; median age, 68 years) with 310 lung tumors (82% metastases) underwent 208 cryoablations (HFJV, n = 129; SR, n = 79). HFJV showed greater rates than SR for the treatment of multiple tumors per session (43% vs 19%, respectively; p = .02) and tumors in a nonperipheral location (48% vs 24%, p < .001). Major adverse event rate was 8% for HFJV and 5% for SR (p = .46). No systemic air embolism occurred. HLOS was 2 days or more in 17% of sessions and did not differ significantly between HFJV and SR (p = .64), including after adjusting for probe number per session, chronic obstructive pulmonary disease, and operator experience (p = .53). Ventilation modalities showed no significant difference in procedure time, CT guidance acquisition time, CT guidance radiation dose, or total radiation dose (all p > .05). Room time was longer for HFJV than SR (median, 154 vs 127 minutes, p < .001). For HFJV, the median anesthesia time was 136 minutes. Ventilation modalities did not differ in the frequencies of pneumothorax or pneumothorax requiring chest tube placement (both p > .05). CONCLUSION. HFJV appears to be as safe as SR but had longer room times. HFJV can be used in complex cases without significantly impacting HLOS of 2 days or more, procedure time, or radiation exposure. CLINICAL IMPACT. Selection of the ventilation modality during percutaneous lung ablation should be based on patient characteristics and anticipated procedural requirements as well as operator preference.
Collapse
Affiliation(s)
- Alexander Graur
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
- Department of Radiology, Ludwig-Maximilians-University, Munich, Germany
| | | | - Judit Simon
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Cagatay Alici
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Jonathan A Saenger
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
- Department of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Alexis M Cahalane
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| | - Rafael Vazquez
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, MA
| | - Florian J Fintelmann
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
| |
Collapse
|
6
|
Spenkelink IM, Zhu X, Fütterer JJ, Langenhuijsen JF. Feasibility of stereotactic optical navigation for needle positioning in percutaneous nephrolithotomy. World J Urol 2024; 42:181. [PMID: 38507097 PMCID: PMC10954992 DOI: 10.1007/s00345-024-04870-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 02/08/2024] [Indexed: 03/22/2024] Open
Abstract
BACKGROUND This study assessed the feasibility of acquiring single-attempt access to the pelvicalyceal system during percutaneous nephrolithotomy (PCNL) using stereotactic optical navigation combined with cone-beam CT (CBCT) imaging. METHODS Patients with a PCNL indication were prospectively included in this IRB approved study. After sterile preparation, fiducial markers were attached to patients' skin. An initial intraprocedural CBCT scan was acquired, on which the urologist planned the needle trajectory using the navigation software. After verifying that no critical structures were crossed, the needle guide was aligned with the plan. A needle was manually inserted through the needle guide to the indicated depth and a second CBCT scan was performed for needle position confirmation. Both, scanning and needle insertion, were performed under apnea. The study evaluated technical success, accuracy, procedure time, complication rate, and radiation dose. RESULTS Between June 2022 and April 2023, seven patients were included. In all patients, the navigation system allowed safe puncture. However, the technical success rate was only 29%. In 42% of the cases, pelvicalyceal access was achieved by a small manual adjustment. In the remaining 29%, the needle was retracted and positioned per clinical standard. The average deviation between the needle and target was 5.9 ± 2.3 mm. The average total procedure time was 211 ± 44 min. The average radiation exposure was 6.4 mSv, with CBCT scanning contributing to 82% of this exposure. CONCLUSIONS The optical navigation system facilitated safe needle insertion but did not consistently ensure accurate one-attempt needle positioning for PCNL. Real-time visualization and trajectory correction may improve the technical success rate.
Collapse
Affiliation(s)
- I M Spenkelink
- Department of Medical Imaging, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
| | - X Zhu
- Department of Urology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - J J Fütterer
- Department of Medical Imaging, Radboud University Medical Center, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - J F Langenhuijsen
- Department of Urology, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
7
|
Matsui Y, Kamegawa T, Tomita K, Uka M, Umakoshi N, Kawabata T, Munetomo K, Iguchi T, Matsuno T, Hiraki T. Robotic systems in interventional oncology: a narrative review of the current status. Int J Clin Oncol 2024; 29:81-88. [PMID: 37115426 DOI: 10.1007/s10147-023-02344-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 04/13/2023] [Indexed: 04/29/2023]
Abstract
Interventional oncology offers minimally invasive treatments for malignant tumors for curative and palliative purposes based on the percutaneous insertion of needles or catheters into the target location under image guidance. Robotic systems have been gaining increasing attention as tools that provide potential advantages for image-guided interventions. Among the robotic systems developed for intervention, those relevant to the oncology field are mainly those for guiding or driving the needles in non-vascular interventional procedures such as biopsy and tumor ablation. Needle-guiding robots support planning the needle path and align the needle robotically according to the planned trajectory, which is combined with subsequent manual needle insertion by the physician through the needle guide. Needle-driving robots can advance the needle robotically after determining its orientation. Although a wide variety of robotic systems have been developed, only a limited number of these systems have reached the clinical phase or commercialization thus far. The results of previous studies suggest that such interventional robots have the potential to increase the accuracy of needle placement, facilitate out-of-plane needle insertion, decrease the learning curve, and reduce radiation exposure. On the other hand, increased complexity and costs may be a concern when using robotic systems compared with conventional manual procedures. Further data should be collected to comprehensively assess the value of robotic systems in interventional oncology.
Collapse
Affiliation(s)
- Yusuke Matsui
- Department of Radiology, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, 2-5-1 Shikata-Cho, Kita-Ku, Okayama, 700-8558, Japan.
| | - Tetsushi Kamegawa
- Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama, Japan
| | - Koji Tomita
- Department of Radiology, Okayama University Hospital, Okayama, Japan
| | - Mayu Uka
- Department of Radiology, Okayama University Hospital, Okayama, Japan
| | - Noriyuki Umakoshi
- Department of Radiology, Okayama University Hospital, Okayama, Japan
| | - Takahiro Kawabata
- Department of Radiology, Okayama University Hospital, Okayama, Japan
| | - Kazuaki Munetomo
- Department of Radiology, Okayama University Hospital, Okayama, Japan
| | - Toshihiro Iguchi
- Department of Radiological Technology, Faculty of Health Sciences, Okayama University, Okayama, Japan
| | - Takayuki Matsuno
- Faculty of Natural Science and Technology, Okayama University, Okayama, Japan
| | - Takao Hiraki
- Department of Radiology, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, 2-5-1 Shikata-Cho, Kita-Ku, Okayama, 700-8558, Japan
| |
Collapse
|
8
|
Bale R, Laimer G, Schullian P, Alzaga A. Stereotactic ablation: A game changer? J Med Imaging Radiat Oncol 2023; 67:886-894. [PMID: 37401185 DOI: 10.1111/1754-9485.13555] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 06/23/2023] [Indexed: 07/05/2023]
Abstract
For both primary and metastatic liver cancer, thermal ablation represents an interesting alternative to surgery. However, except for a small fraction of patients, conventional ultrasound- and CT-guided single-probe approaches have not achieved oncologic outcomes comparable with surgery. In this overview, we describe our stereotactic ablation workflow and discuss the short- and long-term results of stereotactic radiofrequency ablation (SRFA) and stereotactic microwave ablation (SMWA) for the treatment of primary and secondary liver tumours. The advantages of this method are discussed together with a summary of the existing stereotactic techniques for thermal ablation and the clinical data that support them. Stereotactic ablation is based on an optical navigation system and a specialized aiming tool. The workflow includes advanced three-dimensional planning, precise needle/probe placements according to the plan and intraoperative image fusion to check the needle positions and the ablation margins. Stereotactic ablation offers all the advantages of a minimally invasive procedure while producing oncological results comparable with surgery. The number of locally treatable liver cancers may be significantly expanded with these cutting-edge instruments and methods. We firmly believe that it can become a cornerstone in the treatment of liver cancers.
Collapse
Affiliation(s)
- Reto Bale
- Interventional Oncology/Stereotaxy and Robotics, Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria
| | - Gregor Laimer
- Interventional Oncology/Stereotaxy and Robotics, Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria
| | - Peter Schullian
- Interventional Oncology/Stereotaxy and Robotics, Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria
| | | |
Collapse
|
9
|
Zhang Y, Wang MY, Wang LK, Zhang S, Sun H, Liu J. Preliminary study of 3D printing technology for extracorporeal positioning guide assisted ultrasound-guided microwave ablation of the liver. Expert Rev Med Devices 2023; 20:1227-1233. [PMID: 37897059 DOI: 10.1080/17434440.2023.2277233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Accepted: 10/19/2023] [Indexed: 10/29/2023]
Abstract
BACKGROUND We designed a 3D-printed extracorporeal positioning guide for assisting ultrasound-guided microwave ablation of the liver and observed its effectiveness. RESEARCH DESIGN AND METHODS 13 patients with liver cancer were selected, and their CT data were obtained. The CT data is reconstructed in 3D by computer software Mimics to create a 3D model. The 3D-printed in vitro positioning guides were designed by 3-Matic and fabricated using 3D printing technology. Finally, it is applied to the clinic, and its effect is observed. RESULTS The preliminary design of a 3D printed extracorporeal positioning guide was applied to the clinic, and the efficiency of assisted ultrasound positioning was 76.92% (10/13), with three patients requiring repositioning. The efficiency of the 3D printed extracorporeal positioning guide technique was 76.92%, a CT examination was performed one month after surgery, and three patients had residual lesions. CONCLUSIONS 3D-printed extracorporeal positioning guides can assist ultrasound in localizing tumors during liver microwave ablation and reduce repeated punctures. It makes percutaneous microwave ablation of the liver more precise and safe. However, the current study sample is small, there are still apparent shortcomings, and long-term clinical studies are needed to prove its effectiveness.
Collapse
Affiliation(s)
- Yu Zhang
- Guizhou University Medical College, Guiyang, Guizhou Province, China
| | - Ming-Yue Wang
- Guizhou Medoll Company, Oriental Pearl Tower, Guizhou Province, China
| | - Li-Kui Wang
- Guizhou Medoll Company, Oriental Pearl Tower, Guizhou Province, China
| | - Sha Zhang
- Guizhou Medoll Company, Oriental Pearl Tower, Guizhou Province, China
| | - Hong Sun
- Guizhou Medoll Company, Oriental Pearl Tower, Guizhou Province, China
| | - Jun Liu
- Guizhou University Medical College, Guiyang, Guizhou Province, China
- Guizhou Provincial People's Hospital, Guiyang, Guizhou Province, China
| |
Collapse
|
10
|
Trochu T, Desfriches-Doria N, Grillot N, Feuillet F, Lair D, Liberge R, Douane F, Dumont R, David A. Safety of High-Frequency Jet Ventilation During Image-Guided Thermal Ablation Procedures. Cardiovasc Intervent Radiol 2023; 46:360-368. [PMID: 36658374 DOI: 10.1007/s00270-023-03358-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 01/02/2023] [Indexed: 01/20/2023]
Abstract
RATIONALE AND OBJECTIVE Percutaneous thermal ablative technique is a common radiological procedure for malignant lesions treatment. Controlled assisted ventilation during general anesthesia is the usual mode of ventilation, but high-frequency jet ventilation (HFJV) can be a helpful alternative for the operator. The objective was to evaluate the safety of HFJV during thermal ablation procedures. MATERIALS AND METHODS This monocentric prospective analysis included adult patients undergoing percutaneous thermal ablation procedures for abdominal tumor performed under HFJV. Procedures with a transpulmonary path were excluded. The primary outcome was the incidence of respiratory complications. Secondary outcomes included gas exchange modifications (hypercapnia, hypoxemia, pulmonary atelectasis) and the incidence of barotrauma. RESULTS Sixty patients were included during the study period. The mean duration time was 88 min. All procedures went according to the protocol and there was no respiratory complication. There was no barotrauma event. Three patients had an exhaled capnia above 45 mmHg at the end of the procedure which normalized within 10 min of conventional ventilation. CONCLUSION HFJV during thermal ablation procedures is safe regarding gas exchange and barotrauma. This technique could be an interesting alternative to conventional ventilation during image-guided thermal ablation procedures. Clinical Trials database This study was registered in Clinical Trials database (NCT04209608).
Collapse
Affiliation(s)
- Théophane Trochu
- Department of Radiology, Nantes University Hospital, 1, place Alexis Ricordeau, 44093, Nantes, France.
| | - Nathalie Desfriches-Doria
- Pôle d'Anesthésie Réanimation Chirurgicale, CHU Nantes, Université de Nantes, Hôtel-Dieu, 1, place Alexis Ricordeau, 44093, Nantes, France
| | - Nicolas Grillot
- Pôle d'Anesthésie Réanimation Chirurgicale, CHU Nantes, Université de Nantes, Hôtel-Dieu, 1, place Alexis Ricordeau, 44093, Nantes, France
| | - Fanny Feuillet
- SPHERE U1246, DRCI, Plateforme de Méthodologie et de Biostatistique, INSERM, CHU Nantes & Nantes Université, Université de Tours, 1, place Alexis Ricordeau, 44093, Nantes, France
| | - David Lair
- Research and Innovation Department, CHU Nantes, Nantes Université, 53, Chaussée de la Madeleine, 44000, Nantes, France
| | - Renan Liberge
- Department of Radiology, Nantes University Hospital, 1, place Alexis Ricordeau, 44093, Nantes, France
| | - Frédéric Douane
- Department of Radiology, Nantes University Hospital, 1, place Alexis Ricordeau, 44093, Nantes, France
| | - Romain Dumont
- Pôle d'Anesthésie Réanimation Chirurgicale, CHU Nantes, Université de Nantes, Hôtel-Dieu, 1, place Alexis Ricordeau, 44093, Nantes, France
| | - Arthur David
- Department of Radiology, Nantes University Hospital, 1, place Alexis Ricordeau, 44093, Nantes, France
| |
Collapse
|
11
|
Tinguely P, Laurell G, Enander A, Engstrand J, Freedman J. Ablation versus resection for resectable colorectal liver metastases - Health care related cost and survival analyses from a quasi-randomised study. EUROPEAN JOURNAL OF SURGICAL ONCOLOGY 2023; 49:416-425. [PMID: 36123245 DOI: 10.1016/j.ejso.2022.09.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 09/07/2022] [Accepted: 09/07/2022] [Indexed: 11/16/2022]
Abstract
BACKGROUND The aim of this study was to compare healthcare related costs and survival in patients treated with microwave ablation (MWA) versus surgical resection for resectable colorectal liver metastases (CRLM), in patients from a quasi-randomised setting. METHODS The Swedish subset of data from a prospective multi-centre study investigating survival after percutaneous computer-assisted Microwave Ablation VErsus Resection for Resectable CRLM (MAVERRIC study) was analysed. Patients with CRLM ≤ 3 cm amenable to ablation and resection were considered for study inclusion only on even calendar weeks, while treated with gold standard resection every other week, creating a quasi-randomised setting. Survival and costs (all inpatient hospital admissions, outpatient visits, oncological treatments and radiological imaging) in the 2 years following treatment were investigated. RESULTS MWA (n = 52) and resection (n = 53) cohorts had similar baseline patient and tumour characteristics and health care consumption within 1 year prior to CRLM treatment. Treatment related morbidity and length of stay were significantly higher in the resected cohort. Overall health care related costs from decision of treatment and 2 years thereafter were lower in the MWA versus resection cohort (mean ± SD USD 80'964±59'182 versus 110'059±59'671, P < 0.01). Five-year overall survival was 50% versus 54% in MWA versus resection groups (P = 0.95). CONCLUSIONS MWA is associated with decreased morbidity, time spent in medical facilities and healthcare related costs within 2 years of initial treatment with equal overall survival, highlighting its benefits for patient and health care systems.
Collapse
Affiliation(s)
- Pascale Tinguely
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
| | - Gustaf Laurell
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
| | - Anton Enander
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
| | - Jennie Engstrand
- Division of Surgery, Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Karolinska University Hospital, 141 86, Stockholm, Sweden.
| | - Jacob Freedman
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
| |
Collapse
|
12
|
Lanza C, Carriero S, Buijs EFM, Mortellaro S, Pizzi C, Sciacqua LV, Biondetti P, Angileri SA, Ianniello AA, Ierardi AM, Carrafiello G. Robotics in Interventional Radiology: Review of Current and Future Applications. Technol Cancer Res Treat 2023; 22:15330338231152084. [PMID: 37113061 PMCID: PMC10150437 DOI: 10.1177/15330338231152084] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/29/2023] Open
Abstract
This review is a brief overview of the current status and the potential role of robotics in interventional radiology. Literature published in the last decades, with an emphasis on the last 5 years, was reviewed and the technical developments in robotics and navigational systems using CT-, MR- and US-image guidance were analyzed. Potential benefits and disadvantages of their current and future use were evaluated. The role of fusion imaging modalities and artificial intelligence was analyzed in both percutaneous and endovascular procedures. A few hundred articles describing results of single or several systems were included in our analysis.
Collapse
Affiliation(s)
- Carolina Lanza
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Milan, Italy
| | - Serena Carriero
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Milan, Italy
| | | | - Sveva Mortellaro
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Milan, Italy
| | - Caterina Pizzi
- Postgraduate School in Radiodiagnostics, Università degli Studi di Milano, Milan, Italy
| | | | - Pierpaolo Biondetti
- Foundation IRCCS Cà Granda-Ospedale Maggiore Policlinico, Milan, Italy
- Università degli Studi di Milano, Milan, Italy
| | | | | | | | - Gianpaolo Carrafiello
- Foundation IRCCS Cà Granda-Ospedale Maggiore Policlinico, Milan, Italy
- Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
13
|
Stereotactic Microwave Ablation of Hepatocellular Carcinoma: The Impact of Tumor Size and Minimal Ablative Margin on Therapeutic Success. Tomography 2022; 9:50-59. [PMID: 36648992 PMCID: PMC9844395 DOI: 10.3390/tomography9010005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 12/19/2022] [Accepted: 12/23/2022] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Microwave ablation (MWA) has gained relevance in the treatment of hepatic malignancies and especially in hepatocellular carcinoma (HCC), and it is an important alternative to surgery. The purpose of the study was to evaluate whether the minimal ablative margin (MAM) or the initial tumor size has a greater effect on the success of stereotactic MWA of HCC regarding the time to local tumor progression (LTP) and overall survival (OS). METHODS 88 patients, who received stereotactic MWA of 127 tumor lesions with a curative intention were included in this single-center, retrospective study. The MAM was evaluated in a side-by-side comparison of pre- and post-ablative, contrast-enhanced slice imaging. A Cox proportional hazard model with a frailty term was computed to assess the influence of the MAM and the maximum tumor diameter on the time to LTP and the OS. RESULTS The maximum tumor diameter was identified as a significant positive predictor for LTP (hazard ratio 1.04, 95% CI 1.00-1.08, p = 0.03), but it was not a significant positive predictor for the OS (p = 0.20). The MAM did not have a significant influence on LTP-free survival (p = 0.23) and OS (p = 0.67). CONCLUSION For the successful stereotactic MWA of HCC, the MAM and maximum tumor diameter might not have an influence on the OS, but the maximum tumor diameter seems to be an independent predictor of the time to LTP.
Collapse
|
14
|
de Baère T, Roux C, Deschamps F, Tselikas L, Guiu B. Evaluation of a New CT-Guided Robotic System for Percutaneous Needle Insertion for Thermal Ablation of Liver Tumors: A Prospective Pilot Study. Cardiovasc Intervent Radiol 2022; 45:1701-1709. [PMID: 36127519 DOI: 10.1007/s00270-022-03267-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 08/23/2022] [Indexed: 11/30/2022]
Abstract
PURPOSE To assess the feasibility and safety of a robotic system for percutaneous needle insertion during thermal ablation of liver tumors. MATERIALS AND METHODS This study analyzed the CT-guided percutaneous needle insertion using the EPIONE robotic device (Quantum Surgical, Montpellier, France) for radiofrequency or microwave liver ablation. The main criteria of the study were feasibility (possibility to perform the thermal ablation after needle insertion), the number of needle adjustments (reiteration of robotically assisted needle insertion when initial needle positioning is considered insufficient to perform ablation), and robotic-guided procedure safety (complications related to the needle insertion). Patients were followed up at 6 months post-intervention to assess local tumor control. RESULTS Twenty-one patients with 24 tumors, including 6 HCC and 18 metastases measuring 15.6 ± 7.2 mm, were enrolled. One patient (with one tumor) was excluded for protocol deviation. Robotic assisted thermal ablation was feasible for 22/23 lesions (95.7%) and 19/20 patients (95.0%), as validated by a data safety monitoring Board (95% CI [76.39%; 99.11%]) for the per-protocol population. The mean number of needle adjustments per tumor treated was 0.4 (SD: 0.7), with 70.8% of tumors requiring no adjustment. No adverse events were depicted. Rate of local tumor control was 83.3% for patients and 85.7% for tumors, at 6 months. CONCLUSION This bicentric first-in-human pilot study suggests both feasibility and safety of a stereotactic CT-guided EPIONE device for the percutaneous needle insertion during liver tumor thermal ablation.
Collapse
Affiliation(s)
- Thierry de Baère
- BIOTHERIS, Department of Interventional Radiology, Gustave Roussy, Université Paris-Saclay, 114 rue Edouard Vaillant, 94805, Villejuif, France.
| | - Charles Roux
- BIOTHERIS, Department of Interventional Radiology, Gustave Roussy, Université Paris-Saclay, 114 rue Edouard Vaillant, 94805, Villejuif, France
| | - Frédéric Deschamps
- BIOTHERIS, Department of Interventional Radiology, Gustave Roussy, Université Paris-Saclay, 114 rue Edouard Vaillant, 94805, Villejuif, France
| | - Lambros Tselikas
- BIOTHERIS, Department of Interventional Radiology, Gustave Roussy, Université Paris-Saclay, 114 rue Edouard Vaillant, 94805, Villejuif, France
| | - Boris Guiu
- Department of Radiology, St-Eloi University Hospital, Montpellier, France
| |
Collapse
|
15
|
Hao MZ, Hu YB, Chen QZ, Chen ZX, Lin HL. Efficacy and safety of computed tomography-guided microwave ablation with fine needle-assisted puncture positioning technique for hepatocellular carcinoma. World J Gastrointest Oncol 2022; 14:1727-1738. [PMID: 36187402 PMCID: PMC9516651 DOI: 10.4251/wjgo.v14.i9.1727] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 04/18/2022] [Accepted: 08/01/2022] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND In microwave ablation (MWA), although computed tomography (CT) scanning can overcome gas interference, it cannot achieve real-time localization. Therefore, the puncture technique is more important in CT-guided ablation.
AIM To compare the fine needle-assisted puncture (FNP) positioning technique and the conventional puncture (CP) technique for the safety and efficacy of CT-guided MWA in treating hepatocellular carcinoma (HCC).
METHODS This retrospective study included 124 patients with 166 tumor nodules from February 2018 and June 2021. Seventy patients received CT-guided MWA under the FNP technique (FNP group), and 54 patients received MWA under the CP technique (CP group). Intergroup comparisons were made regarding local tumor progression (LTP), recurrence-free survival (RFS), overall survival (OS), and complications. The influencing variables of LTP and RFS were analyzed through univariate and multivariate regressions.
RESULTS The 1-, 2-, and 3-year cumulative incidences of LTP in the FNP group were significantly lower than those in the CP group (7.4%, 12.7%, 21.3% vs 13.7%, 32.9%, 36.4%; P = 0.038). The 1-, 2-, and 3-year RFS rates in the FNP group were significantly higher than those in the CP group (80.6%, 73.3%, 64.0% vs 83.3%, 39.4%, and 32.5%, respectively; P = 0.008). The FNP technique independently predicted LTP and RFS. Minor complications in the FNP group were lower than those in the CP group (P < 0.001). The difference in median OS was insignificant between the FNP and CP groups (P = 0.229).
CONCLUSION The FNP technique used in CT-guided MWA may improve outcomes in terms of LTP, RFS, and procedure-related complications for HCC.
Collapse
Affiliation(s)
- Ming-Zhi Hao
- Department of Tumor Interventional Radiology, Fujian Medical University Cancer Hospital, Fujian Cancer Hospital, Fuzhou 350014, Fujian Province, China
- Department of Fujian Provincial Key Laboratory of Translational Cancer Medicine, Fujian Cancer Hospital, Fuzhou 350014, Fujian Province, China
| | - Yu-Bin Hu
- Department of Tumor Interventional Radiology, Fujian Medical University Cancer Hospital, Fujian Cancer Hospital, Fuzhou 350014, Fujian Province, China
| | - Qi-Zhong Chen
- Department of Tumor Interventional Radiology, Fujian Medical University Cancer Hospital, Fujian Cancer Hospital, Fuzhou 350014, Fujian Province, China
| | - Zhang-Xian Chen
- Department of Tumor Interventional Radiology, Fujian Medical University Cancer Hospital, Fujian Cancer Hospital, Fuzhou 350014, Fujian Province, China
| | - Hai-Lan Lin
- Department of Tumor Interventional Radiology, Fujian Medical University Cancer Hospital, Fujian Cancer Hospital, Fuzhou 350014, Fujian Province, China
| |
Collapse
|
16
|
Floridi C, Cellina M, Irmici G, Bruno A, Rossini N, Borgheresi A, Agostini A, Bruno F, Arrigoni F, Arrichiello A, Candelari R, Barile A, Carrafiello G, Giovagnoni A. Precision Imaging Guidance in the Era of Precision Oncology: An Update of Imaging Tools for Interventional Procedures. J Clin Med 2022; 11:jcm11144028. [PMID: 35887791 PMCID: PMC9322069 DOI: 10.3390/jcm11144028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/02/2022] [Accepted: 07/08/2022] [Indexed: 02/05/2023] Open
Abstract
Interventional oncology (IO) procedures have become extremely popular in interventional radiology (IR) and play an essential role in the diagnosis, treatment, and supportive care of oncologic patients through new and safe procedures. IR procedures can be divided into two main groups: vascular and non-vascular. Vascular approaches are mainly based on embolization and concomitant injection of chemotherapeutics directly into the tumor-feeding vessels. Percutaneous approaches are a type of non-vascular procedures and include percutaneous image-guided biopsies and different ablation techniques with radiofrequency, microwaves, cryoablation, and focused ultrasound. The use of these techniques requires precise imaging pretreatment planning and guidance that can be provided through different imaging techniques: ultrasound, computed tomography, cone-beam computed tomography, and magnetic resonance. These imaging modalities can be used alone or in combination, thanks to fusion imaging, to further improve the confidence of the operators and the efficacy and safety of the procedures. This article aims is to provide an overview of the available IO procedures based on clinical imaging guidance to develop a targeted and optimal approach to cancer patients.
Collapse
Affiliation(s)
- Chiara Floridi
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (A.B.); (N.R.); (A.A.); (A.G.)
- Division of Special and Pediatric Radiology, Department of Radiology, University Hospital “Umberto I—Lancisi—Salesi”, 60126 Ancona, Italy;
- Division of Interventional Radiology, Department of Radiological Sciences, University Politecnica Delle Marche, 60126 Ancona, Italy;
- Correspondence:
| | - Michaela Cellina
- Radiology Department, Fatebenefratelli Hospital, ASST Fatebenefratelli Sacco, 20122 Milan, Italy;
| | - Giovanni Irmici
- Post-Graduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy; (G.I.); (A.A.)
| | - Alessandra Bruno
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (A.B.); (N.R.); (A.A.); (A.G.)
| | - Nicolo’ Rossini
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (A.B.); (N.R.); (A.A.); (A.G.)
| | - Alessandra Borgheresi
- Division of Special and Pediatric Radiology, Department of Radiology, University Hospital “Umberto I—Lancisi—Salesi”, 60126 Ancona, Italy;
| | - Andrea Agostini
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (A.B.); (N.R.); (A.A.); (A.G.)
| | - Federico Bruno
- Department of Biotechnological and Applied Clinical Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (F.B.); (A.B.)
| | - Francesco Arrigoni
- Emergency and Interventional Radiology, San Salvatore Hospital, 67100 L’Aquila, Italy;
| | - Antonio Arrichiello
- Post-Graduation School in Radiodiagnostics, Università degli Studi di Milano, 20122 Milan, Italy; (G.I.); (A.A.)
| | - Roberto Candelari
- Division of Interventional Radiology, Department of Radiological Sciences, University Politecnica Delle Marche, 60126 Ancona, Italy;
| | - Antonio Barile
- Department of Biotechnological and Applied Clinical Sciences, University of L’Aquila, 67100 L’Aquila, Italy; (F.B.); (A.B.)
| | - Gianpaolo Carrafiello
- Operative Unit of Radiology, Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico di Milano, 20122 Milan, Italy;
- Department of Health Sciences, Università degli Studi di Milano, 20122 Milan, Italy
| | - Andrea Giovagnoni
- Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, 60126 Ancona, Italy; (A.B.); (N.R.); (A.A.); (A.G.)
- Division of Special and Pediatric Radiology, Department of Radiology, University Hospital “Umberto I—Lancisi—Salesi”, 60126 Ancona, Italy;
| |
Collapse
|
17
|
Ma L, Liang H, Han B, Yang S, Zhang X, Liao H. Augmented reality navigation with ultrasound-assisted point cloud registration for percutaneous ablation of liver tumors. Int J Comput Assist Radiol Surg 2022; 17:1543-1552. [PMID: 35704238 DOI: 10.1007/s11548-022-02671-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Accepted: 05/02/2022] [Indexed: 11/28/2022]
Abstract
PURPOSE We present a novel augmented reality (AR) surgical navigation method with ultrasound-assisted point cloud registration for percutaneous ablation of liver tumors. A preliminary study is carried out to verify its feasibility. METHODS Two three-dimensional (3D) point clouds of the liver surface are derived from the preoperative images and intraoperative tracked US images, respectively. To compensate for the soft tissue deformation, the point cloud registration between the preoperative images and the liver is performed using the non-rigid iterative closest point (ICP) algorithm. A 3D AR device based on integral videography technology is designed to accurately display naked-eye 3D images for surgical navigation. Based on the above registration, naked-eye 3D images of the liver surface, planning path, entry points, and tumor can be overlaid in situ through our 3D AR device. Finally, the AR-guided targeting accuracy is evaluated through entry point positioning. RESULTS Experiments on both the liver phantom and in vitro pork liver were conducted. Several entry points on the liver surface were used to evaluate the targeting accuracy. The preliminary validation on the liver phantom showed average entry-point errors (EPEs) of 2.34 ± 0.45 mm, 2.25 ± 0.72 mm, 2.71 ± 0.82 mm, and 2.50 ± 1.11 mm at distinct US point cloud coverage rates of 100%, 75%, 50%, and 25%, respectively. The average EPEs of the deformed pork liver were 4.49 ± 1.88 mm and 5.02 ± 2.03 mm at the coverage rates of 100% and 75%, and the average covered-entry-point errors (CEPEs) were 4.96 ± 2.05 mm and 2.97 ± 1.37 mm at 50% and 25%, respectively. CONCLUSION Experimental outcomes demonstrate that the proposed AR navigation method based on US-assisted point cloud registration has achieved an acceptable targeting accuracy on the liver surface even in the case of liver deformation.
Collapse
Affiliation(s)
- Longfei Ma
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Hanying Liang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Boxuan Han
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Shizhong Yang
- Hepato-Pancreato-Biliary Center, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, 102218, China
| | - Xinran Zhang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Hongen Liao
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China.
| |
Collapse
|
18
|
Dong Y, Wang G, Zhang J, Zhang S, Chen X, Guo Q, Qu F, Shou F. Robotic laser position versus freehand in CT-guided percutaneous microwave ablation for single hepatocellular carcinoma (diameter < 3 cm): a preliminary study. Int J Hyperthermia 2022; 39:725-732. [PMID: 35584811 DOI: 10.1080/02656736.2022.2072526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Abstract
PURPOSE To compare the accuracy and safety of robotic laser position (RLP) versus freehand for antenna CT-guided microwave ablation (MWA) of single hepatocellular carcinoma (HCC) (diameter < 3 cm). MATERIALS AND METHODS This retrospective study was conducted between May 2020 and June 2021. A total of 40 patients with early HCC who underwent CT-guided MWA were divided into two groups: a freehand group (n = 20) and a RLP group (n = 20). Based on in-plane and out-of-plane data, the actual puncture point error (APPE), number of repositioning procedures, and operative duration were compared using the Mann-Whitney U test. Ablation-related complications were compared using the Chi-squared test. RESULTS The mean diameter of HCC patients who received MWA was 2.4 ± 0.5 cm. For in-plane APPE, APPE was comparable between the two groups (p = 0.299). However, for the out-of-plane position, the APPE in the freehand group was higher than that in the RLP group (p = 0.027). The number of repositioning procedures was 0 (range, 0-0) for RLP-guided procedures and 3 (range, 2-5) for freehand procedures, showing a statistically significant difference between the two groups (p < 0.001). The mean operative duration for freehand procedures was 39 min, compared with 26 min for RLP-guided procedures, showing a significant difference (p = 0.013). No deaths or major complications were directly related to MWA. Minor complications in the freehand group were comparable with those in the RLP group (p = 0.313). CONCLUSION RLP guidance significantly reduces the number of antenna repositioning procedures in MWA and improves puncture accuracy for target HCC out-of-plane. In addition, the operative duration of robotic guidance was shorter than that of freehand guidance.
Collapse
Affiliation(s)
- Yuru Dong
- Department of Radiology, The Third Medical Center of PLA General Hospital, Beijing, China
| | - Guisheng Wang
- Department of Radiology, The Third Medical Center of PLA General Hospital, Beijing, China
| | - Jingjun Zhang
- Department of Oncology, The People's Hospital of Jianyang City, Chengdu, China
| | - Shu Zhang
- Research Center for Birth Defects Prevention and Control Technology, Chinese PLA General Hospital, Beijing, China
| | - Xiaoxia Chen
- Department of Radiology, The Third Medical Center of PLA General Hospital, Beijing, China
| | - Qing Guo
- Department of Research, Characteristic Medical Center of Chinese People's Armed Police Force, Tianjin, China
| | - Feihuan Qu
- Readitec Medical Systems (Chengdu) Co., Ltd, Chengdu, China
| | - Feng Shou
- Department of Oncology, The People's Hospital of Jianyang City, Chengdu, China
| |
Collapse
|
19
|
Paolucci I, Ruiter SJS, Freedman J, Candinas D, de Jong KP, Weber S, Tinguely P. Volumetric analyses of ablation dimensions in microwave ablation for colorectal liver metastases. Int J Hyperthermia 2022; 39:639-648. [DOI: 10.1080/02656736.2021.1965224] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Affiliation(s)
- Iwan Paolucci
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland
| | - Simeon J. S. Ruiter
- Department of Hepato-Pancreato-Biliary Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Jacob Freedman
- Department of Clinical Sciences, Danderyd Hospital, Karolinska Institute, Stockholm, Sweden
| | - Daniel Candinas
- Department of Visceral Surgery and Medicine, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland
| | - Koert P. de Jong
- Department of Hepato-Pancreato-Biliary Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Stefan Weber
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland
| | - Pascale Tinguely
- Department of Clinical Sciences, Danderyd Hospital, Karolinska Institute, Stockholm, Sweden
- Department of Visceral Surgery and Medicine, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland
| |
Collapse
|
20
|
de Baere T, Roux C, Noel G, Delpla A, Deschamps F, Varin E, Tselikas L. Robotic assistance for percutaneous needle insertion in the kidney: preclinical proof on a swine animal model. Eur Radiol Exp 2022; 6:13. [PMID: 35257224 PMCID: PMC8901810 DOI: 10.1186/s41747-022-00265-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Accepted: 01/17/2022] [Indexed: 01/04/2023] Open
Abstract
Abstract
Background
We evaluated the accuracy, safety, and feasibility of a computed tomography (CT)-guided robotic assistance system for percutaneous needle placement in the kidney.
Methods
Fiducials surgically implanted into the kidneys of two pigs were used as targets for subsequent robotically-assisted needle insertion. Robotically-assisted needle insertions and CT acquisitions were coordinated using respiratory monitoring. An initial scan volume data set was used for needle insertion planning defining skin entry and target point. Then, needle insertion was performed according to robot positioning. The accuracy of needle placement was evaluated upon the distance between the needle tip and the predefined target on a post needle insertion scan. A delayed contrast-enhanced CT scan was acquired to assess safety.
Results
Eight needle trajectories were performed with a median procedural time measured from turning on the robotic system to post needle insertion CT scan of 21 min (interquartile range 15.5−26.5 min). Blind review of needle placement accuracy was 2.3 ± 1.2 mm (mean ± standard deviation) in lateral deviation, 0.7 ± 1.7 mm in depth deviation, and 2.8 ± 1.3 mm in three-dimensional Euclidian deviation. All needles were inserted on the first attempt, which determined 100% feasibility, without needle readjustment. The angulation and length of the trajectory did not impact on the needle placement accuracy. Two minor procedure-related complications were encountered: 2 subcapsular haematomas (13 × 6 mm and 35 × 6 mm) in the same animal.
Conclusions
Robotically-assisted needle insertion was shown feasible, safe and accurate in a swine kidney model. Further larger studies are needed.
Collapse
|
21
|
Stillström D, Eigl B, Freedman J. Stereotactic navigation versus ultrasound guidance in placing IRE applicators in a liver phantom. Sci Rep 2021; 11:21031. [PMID: 34702894 PMCID: PMC8548523 DOI: 10.1038/s41598-021-00505-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 10/08/2021] [Indexed: 11/20/2022] Open
Abstract
The aim of this study was to compare the accuracy of stereotactic CT-guided navigation and ultrasound guided navigation for placing electrodes in Irreversible electroporation in a liver phantom. A liver phantom with multiple tumours was used and interventionists placed four IRE electrodes around each tumour guided either by stereotactic CT-guided navigation or ultrasound. The goal was to place them in a perfect 20 × 20 mm square with parallel electrodes. After each treatment, a CT-scan was performed. The accuracy in pairwise electrode distance, pairwise parallelism and time per tumour was analysed. Eight interventionists placed four electrodes around 55 tumours, 25 with ultrasound and 30 with stereotactic CT-guided navigation. 330 electrode pairs were analysed, 150 with ultrasound and 180 with stereotactic CT-navigation. The absolute median deviation from the optimal distance was 1.3 mm (range 0.0 to 11.3 mm) in the stereotactic CT-navigation group versus 7.1 mm (range 0.3 to 18.1 mm) in the Ultrasound group (p < 0.001). The mean angle between electrodes in each pair was 2.7 degrees (95% CI 2.4 to 3.1 degrees) in the stereotactic CT-navigation group and 5.5 degrees (95% CI 5.0 to 6.1 degrees) in the Ultrasound group (p < 0.001). The mean time for placing the electrodes was 15:11 min (95% CI 13:05 to 17:18 min) in the stereotactic CT-navigation group and 6:40 min (95% CI 5:28 to 7:52 min) in the Ultrasound group. The use of stereotactic CT-navigation in placing IRE-electrodes in a liver phantom is more accurate, but more time consuming, compared to ultrasound guidance.
Collapse
Affiliation(s)
- David Stillström
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden. .,Department of Surgery and Urology, Danderyd Hospital, 182 88, Stockholm, Sweden.
| | | | - Jacob Freedman
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
| |
Collapse
|
22
|
Tinguely P, Paolucci I, Ruiter SJS, Weber S, de Jong KP, Candinas D, Freedman J, Engstrand J. Stereotactic and Robotic Minimally Invasive Thermal Ablation of Malignant Liver Tumors: A Systematic Review and Meta-Analysis. Front Oncol 2021; 11:713685. [PMID: 34631539 PMCID: PMC8495244 DOI: 10.3389/fonc.2021.713685] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Accepted: 09/06/2021] [Indexed: 01/17/2023] Open
Abstract
Background Stereotactic navigation techniques aim to enhance treatment precision and safety in minimally invasive thermal ablation of liver tumors. We qualitatively reviewed and quantitatively summarized the available literature on procedural and clinical outcomes after stereotactic navigated ablation of malignant liver tumors. Methods A systematic literature search was performed on procedural and clinical outcomes when using stereotactic or robotic navigation for laparoscopic or percutaneous thermal ablation. The online databases Medline, Embase, and Cochrane Library were searched. Endpoints included targeting accuracy, procedural efficiency, and treatment efficacy outcomes. Meta-analysis including subgroup analyses was performed. Results Thirty-four studies (two randomized controlled trials, three prospective cohort studies, 29 case series) were qualitatively analyzed, and 22 studies were included for meta-analysis. Weighted average lateral targeting error was 3.7 mm (CI 3.2, 4.2), with all four comparative studies showing enhanced targeting accuracy compared to free-hand targeting. Weighted average overall complications, major complications, and mortality were 11.4% (6.7, 16.1), 3.4% (2.1, 5.1), and 0.8% (0.5, 1.3). Pooled estimates of primary technique efficacy were 94% (89, 97) if assessed at 1–6 weeks and 90% (87, 93) if assessed at 6–12 weeks post ablation, with remaining between-study heterogeneity. Primary technique efficacy was significantly enhanced in stereotactic vs. free-hand targeting, with odds ratio (OR) of 1.9 (1.2, 3.2) (n = 6 studies). Conclusions Advances in stereotactic navigation technologies allow highly precise and safe tumor targeting, leading to enhanced primary treatment efficacy. The use of varying definitions and terminology of safety and efficacy limits comparability among studies, highlighting the crucial need for further standardization of follow-up definitions.
Collapse
Affiliation(s)
- Pascale Tinguely
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden.,Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Iwan Paolucci
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Simeon J S Ruiter
- Department of Hepato-Pancreato-Biliary Surgery and Liver Transplantation, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Stefan Weber
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Koert P de Jong
- Department of Hepato-Pancreato-Biliary Surgery and Liver Transplantation, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Daniel Candinas
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Jacob Freedman
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
| | - Jennie Engstrand
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
| |
Collapse
|
23
|
Galmén K, Jakobsson JG, Freedman J, Harbut P. Post-operative hypertension during early recovery following liver tumour ablation: A retrospective study. Acta Anaesthesiol Scand 2021; 65:1248-1253. [PMID: 34028010 DOI: 10.1111/aas.13930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 05/05/2021] [Accepted: 05/07/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND High-frequency jet ventilation is necessary to reduce organ movements during stereotactic liver ablation. However, post-operative hypertensive episodes especially following irreversible electroporation ablation compared with microwave ablation initiated this study. The hypothesis was that hypertensive episodes could be related to ventilation or ablation method. METHODS The aim of this retrospective study was to assess the proportion of patients with hypertensive events during recovery following liver ablation under general anaesthesia and to analyse the relation to ventilation and ablation technique. A medical chart review of 134 patients undergoing either high-frequency jet ventilation and microwave ablation (n = 45), high-frequency jet ventilation and irreversible electroporation (n = 44), or conventional ventilation and microwave ablation (n = 45) was performed. The proportion of patients with at least one episode of systolic arterial pressure 140-160, 160-180 or >180 mmHg during early recovery and the impact of ventilation method was studied. RESULTS Out of 134 patients, 100, 75 and 34 patients had at least one episode of mild, moderate and severe hypertension. Microwave ablation, as well as high frequency jet ventilation, was associated with an increased odds ratio for post-operative hypertension. The proportion of patients with at least one severe hypertensive event was 18/45, 9/44 and 7/45, respectively. CONCLUSION Both ventilation and ablation technique had an impact on post-operative hypertensive episodes. The microwave ablation/high-frequency jet ventilation combination increased the risk as compared with irreversible electroporation/high-frequency jet ventilation and microwave ablation/conventional ventilation.
Collapse
Affiliation(s)
- Karolina Galmén
- All at the Institution for Clinical Sciences Karolinska InstituteDanderyd University Hospital Stockholm Sweden
| | - Jan G. Jakobsson
- All at the Institution for Clinical Sciences Karolinska InstituteDanderyd University Hospital Stockholm Sweden
| | - Jacob Freedman
- All at the Institution for Clinical Sciences Karolinska InstituteDanderyd University Hospital Stockholm Sweden
| | - Piotr Harbut
- All at the Institution for Clinical Sciences Karolinska InstituteDanderyd University Hospital Stockholm Sweden
| |
Collapse
|
24
|
Stereotactic Thermal Ablation of Liver Tumors: 3D Planning, Multiple Needle Approach, and Intraprocedural Image Fusion Are the Key to Success-A Narrative Review. BIOLOGY 2021; 10:biology10070644. [PMID: 34356499 PMCID: PMC8301079 DOI: 10.3390/biology10070644] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Revised: 06/29/2021] [Accepted: 07/05/2021] [Indexed: 01/04/2023]
Abstract
Thermal ablation is an emerging, potentially curative approach in treating primary and metastatic liver cancer. Different technologies are available, with radiofrequency ablation (RFA) and microwave ablation (MWA) being the most widely used. Regardless of the technique, destruction of the entire tumor, including an adequate safety margin, is key. In conventional single-probe US- or CT-guided thermal ablation, the creation of such large necrosis zones is often hampered by technical limitations, especially for large tumors (i.e., >2-3 cm). These limitations have been overcome by stereotactic RFA (SRFA): a multiple needle approach with 3D treatment planning and precise stereotactic needle placement combined with intraprocedural image fusion of pre- and post-interventional CT scans for verification of treatment success. With these sophisticated tools and advanced techniques, the spectrum of locally curable liver malignancies can be dramatically increased. Thus, we strongly believe that stereotactic thermal ablation can become a cornerstone in the treatment of liver malignancies, as it offers all the benefits of a minimally invasive method while providing oncological outcomes comparable to surgery. This article provides an overview of current stereotactic techniques for thermal ablation, summarizes the available clinical evidence for this approach, and discusses its advantages.
Collapse
|
25
|
Local control of hepatocellular carcinoma and colorectal liver metastases after surgical microwave ablation without concomitant hepatectomy. Langenbecks Arch Surg 2021; 406:2749-2757. [PMID: 34076718 DOI: 10.1007/s00423-021-02219-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Accepted: 05/27/2021] [Indexed: 02/08/2023]
Abstract
PURPOSE Microwave ablation (MWA) is an accepted technique in the multimodal treatment of hepatocellular carcinoma (HCC) and colorectal liver metastases (CRLM). Study endpoints were to evaluate the local efficacy of surgical MWA in selected patients with oligonodular disease without the combination of liver resection to allow a clear interpretation of the follow-up imaging and compare it to the results on percutaneous MWA available in the literature. METHODS Consecutive MWA-only procedures performed between May 2013 and May 2018 for HCC and CRLM with free-hand ultrasound guidance were identified. MWA systems with 2450 MHz were used. Incomplete ablation (IA) was defined as residual disease within 1 cm of the ablation site at the first post-ablation imaging and local recurrence (LR) as the presence of disease after at least one tumor-free imaging. RESULTS A total of 70 tumors in 47 patients were treated with 46 laparoscopic and 1 open procedures. Each patient had no more than 3 tumors, and median size of the lesions was 15 mm (IQR: 10-22). After a median follow-up of 26 months (IQR: 12-40), IA rate was 8.6% and LR rate was 29.4%. Multivariable analysis showed that vascular proximity (OR = 3.4; 95% CI = 1.26-9.22; p=0.016) was the only significant predictor of the combined outcome IA or LR. DISCUSSION In the present study, after mostly laparoscopic MWA, LR was higher than the rates available in the literature for percutaneous MWA of HCC but lower than in the limited studies analyzing isolated percutaneous MWA of liver metastases. Future developments may help establish the role of each therapeutic modality per tumor, in order to improve the outcomes.
Collapse
|
26
|
Luerken L, Doppler M, Brunner SM, Schlitt HJ, Uller W. Stereotactic Percutaneous Electrochemotherapy as Primary Approach for Unresectable Large HCC at the Hepatic Hilum. Cardiovasc Intervent Radiol 2021; 44:1462-1466. [PMID: 34036404 PMCID: PMC8382613 DOI: 10.1007/s00270-021-02841-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Accepted: 04/05/2021] [Indexed: 12/21/2022]
Abstract
Electrochemotherapy (ECT) is a novel non-thermal ablative technique that combines chemotherapy and the application of electric pulses for reversible cell membrane electroporation. This method was recently performed in the treatment of deep-seated liver tumors during open surgery but experience about percutaneous ECT is rare and further developments like combination of percutaneous ECT with stereotactic navigated devices may be very promising. We report on a case of a 4.7 × 4.5 × 3.5 cm unresectable HCC at the hepatic hilum adjacent to the major vessels and the bile duct that was successfully treated using percutaneous ECT in combination with stereotactic navigation. Follow-up imaging 6 weeks and 6 months after ECT showed complete response.
Collapse
Affiliation(s)
- L Luerken
- Department of Radiology, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany
| | - M Doppler
- Department of Radiology, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany.,Faculty of Medicine, Department of Diagnostic and Interventional Radiology, Medical Center, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany
| | - S M Brunner
- Department of Surgery, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany
| | - H J Schlitt
- Department of Surgery, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany
| | - W Uller
- Department of Radiology, University Hospital Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany. .,Faculty of Medicine, Department of Diagnostic and Interventional Radiology, Medical Center, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| |
Collapse
|
27
|
Advanced Techniques in the Percutaneous Ablation of Liver Tumours. Diagnostics (Basel) 2021; 11:diagnostics11040585. [PMID: 33805107 PMCID: PMC8064108 DOI: 10.3390/diagnostics11040585] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/20/2021] [Accepted: 03/21/2021] [Indexed: 02/07/2023] Open
Abstract
Percutaneous ablation is an accepted treatment modality for primary hepatocellular carcinoma (HCC) and liver metastases. The goal of curative ablation is to cause the necrosis of all tumour cells with an adequate margin, akin to surgical resection, while minimising local damage to non-target tissue. Aside from the ablative modality, the proceduralist must decide the most appropriate imaging modality for visualising the tumour and monitoring the ablation zone. The proceduralist may also employ protective measures to minimise injury to non-target organs. This review article discusses the important considerations an interventionalist needs to consider when performing the percutaneous ablation of liver tumours. It covers the different ablative modalities, image guidance, and protective techniques, with an emphasis on new and advanced ablative modalities and adjunctive techniques to optimise results and achieve satisfactory ablation margins.
Collapse
|
28
|
Sandu RM, Paolucci I, Ruiter SJS, Sznitman R, de Jong KP, Freedman J, Weber S, Tinguely P. Volumetric Quantitative Ablation Margins for Assessment of Ablation Completeness in Thermal Ablation of Liver Tumors. Front Oncol 2021; 11:623098. [PMID: 33777768 PMCID: PMC7988092 DOI: 10.3389/fonc.2021.623098] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 01/05/2021] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND In thermal ablation of liver tumors, complete coverage of the tumor volume by the ablation volume with a sufficient ablation margin is the most important factor for treatment success. Evaluation of ablation completeness is commonly performed by visual inspection in 2D and is prone to inter-reader variability. This work aimed to introduce a standardized approach for evaluation of ablation completeness after CT-guided thermal ablation of liver tumors, using volumetric quantitative ablation margins (QAM). METHODS A QAM computation metric based on volumetric segmentations of tumor and ablation areas and signed Euclidean surface distance maps was developed, including a novel algorithm to address QAM computation in subcapsular tumors. The code for QAM computation was verified in artificial examples of tumor and ablation spheres simulating varying scenarios of ablation margins. The applicability of the QAM metric was investigated in representative cases extracted from a prospective database of colorectal liver metastases (CRLM) treated with stereotactic microwave ablation (SMWA). RESULTS Applicability of the proposed QAM metric was confirmed in artificial and clinical example cases. Numerical and visual options of data presentation displaying substrata of QAM distributions were proposed. For subcapsular tumors, the underestimation of tumor coverage by the ablation volume when applying an unadjusted QAM method was confirmed, supporting the benefits of using the proposed algorithm for QAM computation in these cases. The computational code for developed QAM was made publicly available, encouraging the use of a standard and objective metric in reporting ablation completeness and margins. CONCLUSION The proposed volumetric approach for QAM computation including a novel algorithm to address subcapsular liver tumors enables precision and reproducibility in the assessment of ablation margins. The quantitative feedback on ablation completeness opens possibilities for intra-operative decision making and for refined analyses on predictability and consistency of local tumor control after thermal ablation of liver tumors.
Collapse
Affiliation(s)
- Raluca-Maria Sandu
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Iwan Paolucci
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Simeon J. S. Ruiter
- Department of Hepato-Pancreato-Biliary Surgery and Liver Transplantation, University Medical Center Groningen, Groningen, Netherlands
| | - Raphael Sznitman
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Koert P. de Jong
- Department of Hepato-Pancreato-Biliary Surgery and Liver Transplantation, University Medical Center Groningen, Groningen, Netherlands
| | - Jacob Freedman
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
| | - Stefan Weber
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Pascale Tinguely
- Division of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden
- Department of Visceral Surgery and Medicine, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland
| |
Collapse
|
29
|
Afaghi P, Lapolla MA, Ghandi K. Percutaneous microwave ablation applications for liver tumors: recommendations for COVID-19 patients. Heliyon 2021; 7:e06454. [PMID: 33748501 PMCID: PMC7966996 DOI: 10.1016/j.heliyon.2021.e06454] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 02/22/2021] [Accepted: 03/04/2021] [Indexed: 02/07/2023] Open
Abstract
Microwave ablation (MWA) is an alternative locoregional therapy to surgical resection of solid tumors in the treatment of malignancies, and is widely used for hepatic tumors. It has a slightly higher overall survival (OS) rate compared to external beam radiation therapy (EBRT), and proton beam therapy (PBT), and better long-term recurrence-free OS rate compared to radiofrequency ablation (RFA). In this paper, current commercial devices, most recent noncommercial designs, and the principles behind them alongside the recently reported developments and issues of MWA are reviewed. The paper also provides microscopic insights on effects of microwave irradiation in the body. Our review shows that MWA is a safe and effective, minimally invasive method with high ablation completion rates. However, for large tumors, the completion rates slightly decrease, and recurrences increase. Thus, for large tumors we suggest using a cooled shaft antenna or multiple antenna placements. Comparisons of the two common ablation frequencies 915 MHz and 2.45 GHz have shown inconsistent results due to non-identical conditions. This review suggests that 915 MHz devices are more effective for ablating large tumors and the theory behind MWA effects corroborates this proposition. However, for small tumors or tumors adjacent to vital organs, 2.45 GHz is suggested due to its more localized ablation zone. Among the antenna designs, the double-slot antenna with a metallic choke seems to be more effective by localizing the radiation around the tip of the antenna, while also preventing backward radiation towards the skin. The review also pertains to the use of MWA in COVID-19 patients and risk factors associated with the disease. MWA should be considered for COVID-19 patients with hepatic tumors as a fast treatment with a short recovery time. As liver injury is also a risk due to COVID-19, it is recommended to apply liver function tests to monitor abnormal levels in alanine aminotransferase (ALT), aspartate aminotransferase (AST), total bilirubin, and other liver function indicators.
Collapse
Affiliation(s)
- Pooya Afaghi
- Department of Chemistry, University of Guelph, ON, Canada
| | | | | |
Collapse
|
30
|
Accuracy of Electrode Placement in IRE Treatment with Navigated Guidance. Cardiovasc Intervent Radiol 2021; 44:968-975. [PMID: 33474604 PMCID: PMC8172499 DOI: 10.1007/s00270-020-02762-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Accepted: 12/24/2020] [Indexed: 01/03/2023]
Abstract
Purpose Evaluate the accuracy of multiple electrode placements in IRE treatment of liver tumours using a stereotactic CT-based navigation system. Method Analysing data from all IRE treatments of liver tumours at one institution until 31 December 2018. Comparing planned with validated electrode placement. Analysing lateral and angular errors and parallelism between electrode pairs Results Eighty-four tumours were treated in 60 patients. Forty-six per cent were hepatocellular carcinoma, and 36% were colorectal liver metastases. The tumours were located in all segments of the liver. Data were complete from 51 treatments. Two hundred and six electrodes and 336 electrode pairs were analysed. The median lateral and angular error, comparing planned and validated electrode placement, was 3.6 mm (range 0.2–13.6 mm) and 3.1° (range 0°–16.1°). All electrodes with a lateral error >10 mm were either re-positioned or excluded before treatment. The median angle between the electrode pairs was 3.8° (range 0.3°–17.2°). There were no electrode placement-related complications. Conclusion The use of a stereotactic CT-based system for navigation of electrode placement in IRE treatment of liver tumours is safe, accurate and user friendly.
Collapse
|
31
|
Poch FG, Geyer B, Gemeinhardt O, Klopfleisch R, Niehues SM, Vahldiek JL, Bressem K, Kreis ME, Lehmann KS. Immediate post-interventional contrast-enhanced computed tomography overestimates hepatic microwave ablation - an in vivo animal study. Int J Hyperthermia 2020; 37:463-469. [PMID: 32396401 DOI: 10.1080/02656736.2020.1762936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
Abstract
Objectives: Contrast-enhanced computed tomography (CECT) is used to monitor technical success immediately after hepatic microwave ablation (MWA). However, it remains unclear, if CECT shows the exact extend of the thermal destruction zone, or if tissue changes such as peri-lesionary edema are depicted as well. The objective of this study was to correlate immediate post-interventional CECT with histological and macroscopic findings in hepatic MWA in porcine liver in vivo.Methods: Eleven MWA were performed in porcine liver in vivo with a microwave generator (928 MHz; energy input 24 kJ). CECT was performed post-interventionally. Livers were explanted and ablations were bisected immediately after ablation. Samples were histologically analyzed after vital staining (NADH-diaphorase). Ablation zones were histologically and macroscopically outlined. We correlated histologic findings, macroscopic images and CECT.Results: Three ablation zones were identified in histological and macroscopic findings. Only one ablation zone could be depicted in CECT. Close conformity was observed between histological and macroscopic findings. The ablation zone depicted in CECT overestimated the histological avital central zone and inner red zone (p < = .01). No differences were found between CECT and the histological outer red zone (p > .05).Conclusions: Immediate post-interventional CECT overestimated the clinically relevant zone of complete cell ablation after MWA in porcine liver in vivo. This entails the risk of incomplete tumor ablation and could lead to tumor recurrence.
Collapse
Affiliation(s)
- Franz G Poch
- Department of General, Visceral and Vascular Surgery, Campus Benjamin Franklin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Beatrice Geyer
- Department of General, Visceral and Vascular Surgery, Campus Benjamin Franklin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Ole Gemeinhardt
- Department of Radiology, Campus Benjamin Franklin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Robert Klopfleisch
- Institute of Veterinary Pathology, Freie Universität Berlin, Berlin, Germany
| | - Stefan M Niehues
- Department of Radiology, Campus Benjamin Franklin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Janis L Vahldiek
- Department of Radiology, Campus Benjamin Franklin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Keno Bressem
- Department of Radiology, Campus Benjamin Franklin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Martin E Kreis
- Department of General, Visceral and Vascular Surgery, Campus Benjamin Franklin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Kai S Lehmann
- Department of General, Visceral and Vascular Surgery, Campus Benjamin Franklin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
32
|
Daunizeau L, Nguyen A, Le Garrec M, Chapelon JY, N'Djin WA. Robot-assisted ultrasound navigation platform for 3D HIFU treatment planning: Initial evaluation for conformal interstitial ablation. Comput Biol Med 2020; 124:103941. [PMID: 32818742 DOI: 10.1016/j.compbiomed.2020.103941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 07/19/2020] [Accepted: 07/27/2020] [Indexed: 10/23/2022]
Abstract
Interstitial Ultrasound-guided High Intensity Focused Ultrasound (USgHIFU) therapy has the potential to deliver ablative treatments which conform to the target tumor. In this study, a robot-assisted US-navigation platform has been developed for 3D US guidance and planning of conformal HIFU ablations. The platform was used to evaluate a conformal therapeutic strategy associated with an interstitial dual-mode USgHIFU catheter prototype (64 elements linear-array, measured central frequency f = 6.5 MHz), developed for the treatment of HepatoCellular Carcinoma (HCC). The platform included a 3D navigation environment communicating in real-time with an open research dual-mode US scanner/HIFU generator and a robotic arm, on which the USgHIFU catheter was mounted. 3D US-navigation was evaluated in vitro for guiding and planning conformal HIFU ablations using a tumor-mimic model in porcine liver. Tumor-mimic volumes were then used as targets for evaluating conformal HIFU treatment planning in simulation. Height tumor-mimics (ovoid- or disc-shaped, sizes: 3-29 cm3) were created and visualized in liver using interstitial 2D US imaging. Robot-assisted spatial manipulation of these images and real-time 3D navigation allowed reconstructions of 3D B-mode US images for accurate tumor-mimic volume estimation (relative error: 4 ± 5%). Sectorial and full-revolution HIFU scanning (angular sectors: 88-360°) could both result in conformal ablations of the tumor volumes, as soon as their radii remained ≤ 24 mm. The presented US navigation-guided HIFU procedure demonstrated advantages for developing conformal interstitial therapies in standard operative rooms. Moreover, the modularity of the developed platform makes it potentially useful for developing other HIFU approaches.
Collapse
Affiliation(s)
- L Daunizeau
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France.
| | - A Nguyen
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - M Le Garrec
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - J Y Chapelon
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| | - W A N'Djin
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France
| |
Collapse
|
33
|
Gupta P, Kalra N, Keshava SN, Chaluvashetty SB, Mukund A, Roy-Choudhury SH, Baijal SS, Khandelwal A, Ananthashayana VH, R. SN, Kulkarni S, Shetty NS, Gupta A, Gupta S. Indian Society of Vascular and Interventional Radiology Expert Consensus Statements for Ablation in Hepatocellular Carcinoma: Part I. JOURNAL OF CLINICAL INTERVENTIONAL RADIOLOGY ISVIR 2020. [DOI: 10.1055/s-0040-1715774] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
AbstractLocoregional therapies play an important role in the management of hepatocellular carcinoma (HCC). Percutaneous ablation is one of the most commonly employed nonsurgical methods for treating very early and early HCC. For small HCCs, ablation is potentially curative and competes with surgical resection. The widespread availability and the spectrum of ablative techniques mandate uniform approach among interventional radiologists. Thus, it is desirable to have a consensus regarding various aspects of liver ablation. This article represents a consensus document of the experts from the Indian Society of Vascular and Interventional Radiology involved in the care of patients with HCC. The statements are presented in two parts.
Collapse
Affiliation(s)
- Pankaj Gupta
- Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Naveen Kalra
- Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Shyamkumar N. Keshava
- Department of Interventional Radiology, Division of Clinical Radiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Sreedhara B. Chaluvashetty
- Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Amar Mukund
- Department of Interventional Radiology, Institute of Liver and Biliary Sciences, New Delhi, Delhi, India
| | | | - Sanjay Saran Baijal
- Department of Interventional Radiology, Medanta, The Medicity, Gurgaon, Haryana, India
| | - Anubhav Khandelwal
- Department of Interventional Radiology, Medanta, The Medicity, Gurgaon, Haryana, India
| | | | - Sathya Narayanan R.
- Department of Interventional Radiology, Division of Clinical Radiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Suyash Kulkarni
- Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, Maharashtra, India
| | | | - Arun Gupta
- Department of Interventional Radiology, Sir Ganga Ram Hospital, New Delhi, Delhi, India
| | - Sanjay Gupta
- Department of Interventional Radiology, MD Anderson Cancer Center, Houston, Texas, United States
| |
Collapse
|
34
|
Cathomas M, Mertineit N, Kim-Fuchs C, Lachenmayer A, Maurer MH. Value of MRI/CT Image Fusion for Targeting "invisible" Lesions in Stereotactic Microwave Ablation (SMWA) of Malignant Liver Lesions: A Retrospective Analysis. Cardiovasc Intervent Radiol 2020; 43:1505-1514. [PMID: 32642989 DOI: 10.1007/s00270-020-02565-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Accepted: 06/20/2020] [Indexed: 12/11/2022]
Abstract
PURPOSE To assess the technical feasibility of MRI/CT image fusion and completeness of ablation treatment for primary or metastatic liver lesions invisible on contrast-enhanced CT planning scans and outcome in patients treated with stereotactic microwave ablation (SMWA). MATERIALS AND METHODS The study was approved by the local ethics committee. Patients who underwent SMWA between January 2015 and December 2018 were retrospectively analyzed. All liver lesions for which MRI/CT fusion was performed due to invisibility on pre-interventional CT planning scans were included and reassessed. The outcome measurement was successful ablation of the lesion at first follow-up imaging. RESULTS During the study period, 236 patients underwent 312 SMWAs with ablation of 496 lesions. Twenty-four lesions in 15 patients (mean age, 62 years; range, 43-80 years) were included. Following MRI/CT image fusion, all 24 lesions could be sufficiently localized to perform SMWA. The first follow-up imaging showed complete ablation of 22 lesions. Two initially incompletely ablated lesions were hepatocellular carcinomas and were successfully re-ablated afterwards. CONCLUSION SMWA with MRI/CT image fusion is an accurate and safe treatment option for patients with liver lesions not detectable on contrast-enhanced CT planning scans. MRI/CT image fusion may allow more patients with malignant liver lesions to benefit from local ablation treatment even if their lesions are not visible on CT planning examinations.
Collapse
Affiliation(s)
- M Cathomas
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - N Mertineit
- Department of Radiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstr. 10, 3010, Bern, Switzerland
| | - C Kim-Fuchs
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - A Lachenmayer
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - M H Maurer
- Department of Radiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstr. 10, 3010, Bern, Switzerland.
| |
Collapse
|
35
|
Tinguely P, Frehner L, Lachenmayer A, Banz V, Weber S, Candinas D, Maurer MH. Stereotactic Image-Guided Microwave Ablation for Malignant Liver Tumors-A Multivariable Accuracy and Efficacy Analysis. Front Oncol 2020; 10:842. [PMID: 32587826 PMCID: PMC7298123 DOI: 10.3389/fonc.2020.00842] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Accepted: 04/28/2020] [Indexed: 12/11/2022] Open
Abstract
Background: Therapeutic success of thermal ablation for liver tumors depends on precise placement of ablation probes and complete tumor destruction with a safety margin. We investigated factors influencing targeting accuracy and treatment efficacy of percutaneous stereotactic image-guided microwave ablation (SMWA) for malignant liver neoplasms. Materials and methods: All consecutive patients treated with SMWA for malignant liver tumors over a 3-year period were analyzed. A computed tomography-based navigation system was used for ablation probe trajectory planning, stereotactic probe positioning, and validation of probe positions and ablation zones. Factors potentially influencing targeting accuracy [target positioning error (TPE)] and treatment efficacy within 6 months [ablation site recurrence (ASR)] were analyzed in a multivariable regression model, including challenging lesion locations (liver segments I, VII, and VIII; subphrenic location). Results: Three hundred one lesions (174 hepatocellular carcinomas, 87 colorectal liver metastases, 17 neuroendocrine tumors, and 23 others) were targeted in 191 interventions in 153 patients. The median TPE per ablation probe was 2.9 ± 2.3 mm (n = 384). Correction of ablation probe positions by repositioning was necessary in 4 out of 301 lesions (1%). Factors significantly influencing targeting accuracy were cirrhosis (R 0.67, CI 0.22-1.12) and targeting trajectory length (R 0.21, CI 0.12-0.29). Factors significantly influencing early ASR were lesion size >30 mm (OR 5.22, CI 2.44-11.19) and TPE >5 mm (OR 2.48, CI 1.06-5.78). Challenging lesion locations had no significant influence on targeting accuracy or early ASR. Conclusions: SMWA allows precise and effective treatment of malignant liver tumors even for lesions in challenging locations, with treatment efficacy depending on targeting accuracy in our model. Allowing for many tumors to be safely reached, SMWA has the potential to broaden treatment eligibility for patients with otherwise difficult to target tumors.
Collapse
Affiliation(s)
- Pascale Tinguely
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Lorenz Frehner
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Anja Lachenmayer
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Vanessa Banz
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Stefan Weber
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Daniel Candinas
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Martin H Maurer
- Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| |
Collapse
|
36
|
Shono N, Ninni B, King F, Kato T, Tokuda J, Fujimoto T. Simulated accuracy assessment of small footprint body-mounted probe alignment device for MRI-guided cryotherapy of abdominal lesions. Med Phys 2020; 47:2337-2349. [PMID: 32141080 PMCID: PMC7889307 DOI: 10.1002/mp.14116] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 02/19/2020] [Accepted: 02/19/2020] [Indexed: 12/11/2022] Open
Abstract
PURPOSE Magnetic resonance imaging (MRI)-guided percutaneous cryotherapy of abdominal lesions, an established procedure, uses MRI to guide and monitor the cryoablation of lesions. Methods to precisely guide cryotherapy probes with a minimum amount of trial-and-error are yet to be established. To aid physicians in attaining precise probe alignment without trial-and-error, a body-mounted motorized cryotherapy-probe alignment device (BMCPAD) with motion compensation was clinically tested in this study. The study also compared the contribution of body motion and organ motion compensation to the guidance accuracy of a body-mounted probe alignment device. METHODS The accuracy of guidance using the BMCPAD was prospectively measured during MRI-guided percutaneous cryotherapies before insertion of the probes. Clinical parameters including patient age, types of anesthesia, depths of the target, and organ sites of target were collected. By using MR images of the target organs and fiducial markers embedded in the BMCPAD, we retrospectively simulated the guidance accuracy with body motion compensation, organ motion compensation, and no compensation. The collected data were analyzed to test the impact of motion compensation on the guidance accuracy. RESULTS Thirty-seven physical guidance of probes were prospectively recorded for sixteen completed cases. The accuracy of physical guidance using the BMCPAD was 13.4 ± 11.1 mm. The simulated accuracy of guidance with body motion compensation, organ motion compensation, and no compensation was 2.4 ± 2.9 mm, 2.2 ± 1.6 mm, and 3.5 ± 2.9 mm, respectively. Data analysis revealed that the body motion compensation and organ motion compensation individually impacted the improvement in the accuracy of simulated guidance. Moreover, the difference in the accuracy of guidance either by body motion compensation or organ motion compensation was not statistically significant. The major clinical parameters impacting the accuracy of guidance were the body and organ motions. Patient age, types of anesthesia, depths of the target, and organ sites of target did not influence the accuracy of guidance using BMCPAD. The magnitude of body surface movement and organ movement exhibited mutual statistical correlation. CONCLUSIONS The BMCPAD demonstrated guidance accuracy comparable to that of previously reported devices for CT-guided procedures. The analysis using simulated motion compensation revealed that body motion compensation and organ motion compensation individually impact the improvement in the accuracy of device-guided cryotherapy probe alignment. Considering the correlation between body and organ movements, we also determined that body motion compensation using the ring fiducial markers in the BMCPAD can be solely used to address both body and organ motions in MRI-guided cryotherapy.
Collapse
Affiliation(s)
- Naoyuki Shono
- Radiology, Brigham and Women’s Hospital, Boston, MA 02115, USA
| | - Brian Ninni
- Radiology, Brigham and Women’s Hospital, Boston, MA 02115, USA
- Canon Healthcare Optics Research Laboratory Boston, Cambridge, MA 02139, USA
| | - Franklin King
- Radiology, Brigham and Women’s Hospital, Boston, MA 02115, USA
| | - Takahisa Kato
- Radiology, Brigham and Women’s Hospital, Boston, MA 02115, USA
- Canon Healthcare Optics Research Laboratory Boston, Cambridge, MA 02139, USA
| | - Junichi Tokuda
- Radiology, Brigham and Women’s Hospital, Boston, MA 02115, USA
| | - Takahiro Fujimoto
- Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto, Kyoto 606-8507, Japan
| |
Collapse
|
37
|
Dynamic path planning for percutaneous procedures in the abdomen during free breathing. Int J Comput Assist Radiol Surg 2020; 15:1195-1203. [PMID: 32436131 DOI: 10.1007/s11548-020-02153-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 04/02/2020] [Indexed: 01/05/2023]
Abstract
PURPOSE Percutaneous procedures are increasingly used for the treatment of tumors in abdominal structures. Most of the time, these procedures are planned based on static preoperative images and do not take into account any motions, while breathing control is not always applicable. In this paper, we present a method to automatically adjust the planned path in real time according to the breathing. METHODS First, an estimation of the organs motions during breathing is performed during an observation phase. Then we propose an approach named Real Time Intelligent Trajectory (RTIT) that consists in finding the most appropriate moments to push the needle along the initially planned path, based on the motions and the distance to surrounding organs. We also propose a second approach called Real Time Straight Trajectory (RTST) that examines sixteen scenarios of needle insertion at constant speed, starting at eight different moments of the breathing cycle with two different speeds. RESULTS We evaluated our methods on six 3D models of abdominal structures built using image datasets and a real-time simulation of breathing movements. We measured the deviation from the initial path, the target positioning error, and the distance of the actual path to risky structures. The path proposed by RTIT approach is compared to the best path proposed by RTST. CONCLUSIONS We show that the RTIT approach is relevant and adapted to breathing movements. The modification of the path remains minimal while collisions with obstacles are avoided. This study on simulations constitutes a first step towards intelligent robotic insertion under real-time image guidance.
Collapse
|
38
|
Sharpe SA, Scott S, Taylor I, Skinner O, Clark SO, Smyth D, McIntyre A, Gleeson FV, Dennis MJ. Use of high frequency jet ventilation as a refinement for imaging macaques with respiratory disease. Lab Anim 2020; 54:386-390. [PMID: 32216534 DOI: 10.1177/0023677220913328] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Imaging is used in human medicine to diagnose disease and monitor treatment efficacy. Computed tomography (CT) positron emission tomography (PET) and magnetic resonance (MR) are applied to animal models of infectious diseases to increase data quality, enhance their relevance to the clinical situation, and to address ethical issues through reduction of numbers and refinement of study designs. The time required for collection of MR and PET-CT scans means that normal breathing produces motion artefacts that can render images unacceptable. We report, for the first time, the use of high frequency jet ventilation (HFJV) for respiratory management during imaging of macaques. HFJV enables continuous gaseous exchange, resulting in cessation of spontaneous breathing motion thus providing a motionless field without the potential stresses induced by repeated breath-hold strategies.
Collapse
Affiliation(s)
- Sally A Sharpe
- Public Health England, National Infection Service, Porton Down, Salisbury, SP4 0JG, UK
| | - Shaun Scott
- The Churchill Hospital, Headington, Oxford, UK
| | - Irene Taylor
- Public Health England, National Infection Service, Porton Down, Salisbury, SP4 0JG, UK
| | - Oliver Skinner
- Public Health England, National Infection Service, Porton Down, Salisbury, SP4 0JG, UK
| | - Simon O Clark
- Public Health England, National Infection Service, Porton Down, Salisbury, SP4 0JG, UK
| | - Donna Smyth
- Public Health England, National Infection Service, Porton Down, Salisbury, SP4 0JG, UK
| | | | | | - Mike J Dennis
- Public Health England, National Infection Service, Porton Down, Salisbury, SP4 0JG, UK
| |
Collapse
|
39
|
Vazquez R, Beermann SL, Fintelmann FJ, Mullen EM, Chitilian H. High-Frequency Jet Ventilation in the Prone Position to Facilitate Cryoablation of a Peridiaphragmatic Pulmonary Neoplasm: A Case Report. A A Pract 2020; 13:169-172. [PMID: 31045587 DOI: 10.1213/xaa.0000000000001024] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Percutaneous cryoablation of pulmonary tumors at the posterior lung base is challenging due to diaphragmatic motion and the requirement for prone positioning. High-frequency jet ventilation allows oxygenation and ventilation with minimal diaphragmatic movement. In this case report, we describe the use of high-frequency jet ventilation in the prone position to facilitate the cryoablation of a peridiaphragmatic pulmonary neoplasm.
Collapse
Affiliation(s)
- Rafael Vazquez
- From the Departments of Anesthesia, Critical Care, and Pain Medicine
| | | | | | - Eleanor M Mullen
- From the Departments of Anesthesia, Critical Care, and Pain Medicine
| | - Hovig Chitilian
- From the Departments of Anesthesia, Critical Care, and Pain Medicine
| |
Collapse
|
40
|
Perrodin SF, Renzulli MM, Maurer MH, Kim-Fuchs C, Candinas D, Beldi G, Lachenmayer A. CAN MICROWAVE ABLATION BE AN ALTERNATIVE TO RESECTION FOR THE TREATMENT OF NEUROENDOCRINE LIVER METASTASES? Endocr Pract 2019; 26:378-387. [PMID: 31859556 DOI: 10.4158/ep-2019-0394] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Objective: Surgical resection of neuroendocrine tumor liver metastases has been proven to improve survival, but the benefit of microwave ablation as an alternative or adjunct to surgery has yet to be assessed. Our hypothesis is that ablation is equal to surgery in terms of local recurrence and survival. Methods: We conducted a retrospective analysis including all patients treated with microwave ablation and/or surgical resection for neuroendocrine liver metastases in our institution between 2008 and 2017. Results: A total of 47 patients and 68 treatments were analyzed, including 34 liver resections, 20 ablations, and 14 combined procedures. A total of 130 individual metastases were treated with ablation, representing a median of 4 per session (range 1-30). While no major complications occurred after ablation, we observed 11 minor and 3 major complications after open surgical resection (P = .0135). Length of stay was significantly shorter after ablation (P = .0008). The majority of patients (33/47, 70.2%) underwent curative procedures, 14 patients underwent (29.8%) debulking procedures. There was no difference in local recurrence rate between tumors treated with ablation or resection. Liver-only disease progression was detected in 29% of the patients and overall progression was detected in 66% of the patients. The mean survival was not significantly different between patients treated with ablation only versus resection with or without ablation (P = .1570). Overall survival was mean 75.3 months (6 to 374 months). Conclusion: Depending on the extent of the liver metastases, microwave ablation might be a safe alternative or addition to resection for neuroendocrine tumor liver metastases with low morbidity and high local efficiency. Abbreviations: CT = computed tomography; MWA = microwave ablation; NET = neuroendocrine tumor; PET = positron emission tomography; RFA = radiofrequency ablation; RFS = recurrence-free survival; SMWA = stereotactic microwave ablation.
Collapse
|
41
|
Abbass MA, Ahmad SA, Mahalingam N, Krothapalli KS, Masterson JA, Rao MB, Barthe PG, Mast TD. In vivo ultrasound thermal ablation control using echo decorrelation imaging in rabbit liver and VX2 tumor. PLoS One 2019; 14:e0226001. [PMID: 31805129 PMCID: PMC6894854 DOI: 10.1371/journal.pone.0226001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Accepted: 11/18/2019] [Indexed: 12/21/2022] Open
Abstract
The utility of echo decorrelation imaging feedback for real-time control of in vivo ultrasound thermal ablation was assessed in rabbit liver with VX2 tumor. High-intensity focused ultrasound (HIFU) and unfocused (bulk) ablation were performed using 5 MHz linear image-ablate arrays. Treatments comprised up to nine lower-power sonications, followed by up to nine higher-power sonications, ceasing when the average cumulative echo decorrelation within a control region of interest exceeded a predefined threshold (- 2.3, log10-scaled echo decorrelation per millisecond, corresponding to 90% specificity for tumor ablation prediction in previous in vivo experiments). This threshold was exceeded in all cases for both HIFU (N = 12) and bulk (N = 8) ablation. Controlled HIFU trials achieved a significantly higher average ablation rate compared to comparable ablation trials without image-based control, reported previously. Both controlled HIFU and bulk ablation trials required significantly less treatment time than these previous uncontrolled trials. Prediction of local liver and VX2 tumor ablation using echo decorrelation was tested using receiver operator characteristic curve analysis, showing prediction capability statistically equivalent to uncontrolled trials. Compared to uncontrolled trials, controlled trials resulted in smaller thermal ablation regions and higher contrast between echo decorrelation in treated vs. untreated regions. These results indicate that control using echo decorrelation imaging may reduce treatment duration and increase treatment reliability for in vivo thermal ablation.
Collapse
Affiliation(s)
- Mohamed A. Abbass
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Syed A. Ahmad
- Dept of Surgery, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Neeraja Mahalingam
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - K. Sameer Krothapalli
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Jack A. Masterson
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Marepalli B. Rao
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
- Dept of Environmental Health, University of Cincinnati, Cincinnati, Ohio, United States of America
| | - Peter G. Barthe
- Guided Therapy Systems/Ardent Sound, Mesa, Arizona, United States of America
| | - T. Douglas Mast
- Dept of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio, United States of America
| |
Collapse
|
42
|
Heinrich F, Schwenderling L, Becker M, Skalej M, Hansen C. HoloInjection: augmented reality support for CT-guided spinal needle injections. Healthc Technol Lett 2019; 6:165-171. [PMID: 32038851 PMCID: PMC6942927 DOI: 10.1049/htl.2019.0062] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Accepted: 10/02/2019] [Indexed: 12/02/2022] Open
Abstract
The correct placement of needles is decisive for the success of many minimally-invasive interventions and therapies. These needle insertions are usually only guided by radiological imaging and can benefit from additional navigation support. Augmented reality (AR) is a promising tool to conveniently provide needed information and may thus overcome the limitations of existing approaches. To this end, a prototypical AR application was developed to guide the insertion of needles to spinal targets using the mixed reality glasses Microsoft HoloLens. The system's registration accuracy was attempted to measure and three guidance visualisation concepts were evaluated concerning achievable in-plane and out-of-plane needle orientation errors in a comparison study. Results suggested high registration accuracy and showed that the AR prototype is suitable for reducing out-of-plane orientation errors. Limitations, like comparatively high in-plane orientation errors, effects of the viewing position and missing image slices indicate potential for improvement that needs to be addressed before transferring the application to clinical trials.
Collapse
Affiliation(s)
- Florian Heinrich
- Faculty of Computer Science, University of Magdeburg, Universitätsplatz 2, 39106 Magdeburg, Germany.,Research Campus STIMULATE, Sandtorstrasse 23, 39106 Magdeburg, Germany
| | - Luisa Schwenderling
- Faculty of Computer Science, University of Magdeburg, Universitätsplatz 2, 39106 Magdeburg, Germany.,Research Campus STIMULATE, Sandtorstrasse 23, 39106 Magdeburg, Germany
| | - Mathias Becker
- Research Campus STIMULATE, Sandtorstrasse 23, 39106 Magdeburg, Germany.,Department of Neuroradiology, University Hospital Magdeburg, Leipziger Strasse 44, 39120 Magdeburg, Germany
| | - Martin Skalej
- Research Campus STIMULATE, Sandtorstrasse 23, 39106 Magdeburg, Germany.,Department of Neuroradiology, University Hospital Magdeburg, Leipziger Strasse 44, 39120 Magdeburg, Germany
| | - Christian Hansen
- Faculty of Computer Science, University of Magdeburg, Universitätsplatz 2, 39106 Magdeburg, Germany.,Research Campus STIMULATE, Sandtorstrasse 23, 39106 Magdeburg, Germany
| |
Collapse
|
43
|
Robotic CT-guided out-of-plane needle insertion: comparison of angle accuracy with manual insertion in phantom and measurement of distance accuracy in animals. Eur Radiol 2019; 30:1342-1349. [PMID: 31773299 PMCID: PMC7033049 DOI: 10.1007/s00330-019-06477-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/30/2019] [Accepted: 09/27/2019] [Indexed: 01/21/2023]
Abstract
Objectives To evaluate the accuracy of robotic CT-guided out-of-plane needle insertion in phantom and animal experiments. Methods A robotic system (Zerobot), developed at our institution, was used for needle insertion. In the phantom experiment, 12 robotic needle insertions into a phantom at various angles in the XY and YZ planes were performed, and the same insertions were manually performed freehand, as well as guided by a smartphone application (SmartPuncture). Angle errors were compared between the robotic and smartphone-guided manual insertions using Student’s t test. In the animal experiment, 6 robotic out-of-plane needle insertions toward targets of 1.0 mm in diameter placed in the kidneys and hip muscles of swine were performed, each with and without adjustment of needle orientation based on reconstructed CT images during insertion. Distance accuracy was calculated as the distance between the needle tip and the target center. Results In the phantom experiment, the mean angle errors of the robotic, freehand manual, and smartphone-guided manual insertions were 0.4°, 7.0°, and 3.7° in the XY plane and 0.6°, 6.3°, and 0.6° in the YZ plane, respectively. Robotic insertions in the XY plane were significantly (p < 0.001) more accurate than smartphone-guided insertions. In the animal experiment, the overall mean distance accuracy of robotic insertions with and without adjustment of needle orientation was 2.5 mm and 5.0 mm, respectively. Conclusion Robotic CT-guided out-of-plane needle insertions were more accurate than smartphone-guided manual insertions in the phantom and were also accurate in the in vivo procedure, particularly with adjustment during insertion. Key Points • Out-of-plane needle insertions performed using our robot were more accurate than smartphone-guided manual insertions in the phantom experiment and were also accurate in the in vivo procedure. • In the phantom experiment, the mean angle errors of the robotic and smartphone-guided manual out-of-plane needle insertions were 0.4° and 3.7° in the XY plane (p < 0.001) and 0.6° and 0.6° in the YZ plane (p = 0.65), respectively. • In the animal experiment, the overall mean distance accuracies of the robotic out-of-plane needle insertions with and without adjustments of needle orientation during insertion were 2.5 mm and 5.0 mm, respectively. Electronic supplementary material The online version of this article (10.1007/s00330-019-06477-1) contains supplementary material, which is available to authorized users.
Collapse
|
44
|
Volpi S, Tsoumakidou G, Loriaud A, Hocquelet A, Duran R, Denys A. Electromagnetic navigation system combined with High-Frequency-Jet-Ventilation for CT-guided hepatic ablation of small US-Undetectable and difficult to access lesions. Int J Hyperthermia 2019; 36:1051-1057. [DOI: 10.1080/02656736.2019.1671612] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Affiliation(s)
- Stephanie Volpi
- Department of Radiology, Centre Hospitalo-Universitaire Vaudois, Interventional Radiology Unit, Lausanne, Switzerland
- Department of Radiology, Institut de Cancerologie de l’Ouest-René Gauducheau, Saint Herblain Cedex, France
| | - Georgia Tsoumakidou
- Department of Radiology, Centre Hospitalo-Universitaire Vaudois, Interventional Radiology Unit, Lausanne, Switzerland
| | - Amélie Loriaud
- Department of Radiology, Centre Hospitalo-Universitaire Vaudois, Interventional Radiology Unit, Lausanne, Switzerland
| | - Arnaud Hocquelet
- Department of Radiology, Centre Hospitalo-Universitaire Vaudois, Interventional Radiology Unit, Lausanne, Switzerland
| | - Rafael Duran
- Department of Radiology, Centre Hospitalo-Universitaire Vaudois, Interventional Radiology Unit, Lausanne, Switzerland
| | - Alban Denys
- Department of Radiology, Centre Hospitalo-Universitaire Vaudois, Interventional Radiology Unit, Lausanne, Switzerland
| |
Collapse
|
45
|
Lachenmayer A, Tinguely P, Maurer MH, Frehner L, Knöpfli M, Peterhans M, Weber S, Dufour JF, Candinas D, Banz V. Stereotactic image-guided microwave ablation of hepatocellular carcinoma using a computer-assisted navigation system. Liver Int 2019; 39:1975-1985. [PMID: 31276296 DOI: 10.1111/liv.14187] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 06/20/2019] [Accepted: 06/26/2019] [Indexed: 02/13/2023]
Abstract
BACKGROUND & AIMS Ablation plays an important role in the treatment of hepatocellular carcinoma. Because image-guided navigation technology has recently entered the clinical setting, we aimed to analyse its safety, therapeutic and procedural efficiency. METHODS Retrospective analysis of patients treated with stereotactic image-guided microwave ablation (SMWA) between January 2015 and December 2017. Interventions were performed using computertomography-guidance with needle trajectory, ablation planning and automatic single-marker patient registration. Needle placement and ablation coverage was controlled by image fusion under general anaesthesia with jet-ventilation. RESULTS In total 174 ablations were performed in 88 patients during 119 interventions. Mean age was 66 (46-84) years, 74 (84.1%) were men and 74% were Child Pugh Class A. Median tumour size was 16 (4-45) mm, 62.2% were BCLC A. Median lateral and longitudinal error of needle placement were 3.2 (0.2-14.1) and 1.6 (0-15.8) mm. Median one tumour (1-4) was ablated per session. One patient developed a Dindo IIIb (0.8%) complication, six minor complications. After re-ablation of 12 lesions, an efficacy rate of 96.3% was achieved. Local tumour progression was 6.3% (11/174). Close proximity to major vessels was significantly correlated with local tumour progression (P < .05). Median overall follow-up was 17.5 months after intervention and 24 months after initial diagnosis. BCLC stage, child class and previous treatment were significantly correlated with overall survival (P < .05). CONCLUSION Stereotactic image-guided microwave ablation is a safe and efficient treatment for HCC offering a curative treatment approach in general and in particular for lesions not detectable on conventional imaging or untreatable because of difficult anatomic locations.
Collapse
Affiliation(s)
- Anja Lachenmayer
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Pascale Tinguely
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Martin H Maurer
- Department of Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Lorenz Frehner
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Marina Knöpfli
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | | | - Stefan Weber
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Jean-François Dufour
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Daniel Candinas
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Vanessa Banz
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| |
Collapse
|
46
|
Perrodin S, Lachenmayer A, Maurer M, Kim-Fuchs C, Candinas D, Banz V. Percutaneous stereotactic image-guided microwave ablation for malignant liver lesions. Sci Rep 2019; 9:13836. [PMID: 31554853 PMCID: PMC6761186 DOI: 10.1038/s41598-019-50159-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Accepted: 09/03/2019] [Indexed: 01/23/2023] Open
Abstract
Thermal ablation has proven beneficial for hepatocellular carcinoma and possibly for colorectal liver metastases, but data is lacking for other liver metastases. Computer-assisted navigation can increase ablation efficacy and broaden its indications. We present our experience with percutaneous stereotactic image-guided microwave ablation (SMWA) for non-colorectal liver metastases (NCRLM), in form of a retrospective study including all SMWA for NCRLM from 2015 to 2017. Indication for SMWA was determined at a multidisciplinary tumorboard. End-points include recurrence, overall and liver-specific disease progression and complications. Twenty-three patients underwent 25 interventions for 40 lesions, including 17 neuroendocrine tumor, nine breast cancer, four sarcoma, two non-small cell lung cancer, three duodenal adenocarcinoma, one esophageal adenocarcinoma, one pancreatic adenocarcinoma, one ampullary carcinoma, one prostate carcinoma, and one renal cell carcinoma metastases. Median follow-up was 15 months (2-32). Incomplete ablation rate was 2.5% (1/40), local recurrence rate 10% (4/40). Three patients (12%) had minor complications. Overall disease progression was 73.9% (17/23), median disease-free survival 7 months (0-26) and overall survival 18 months (2-39). SIMWA is feasible, safe and minimally invasive for NCRLM in selected patients. While it might offer an alternative to resection or palliative strategies, the oncological benefit needs to be evaluated in a larger patient cohort.
Collapse
Affiliation(s)
- Stéphanie Perrodin
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Anja Lachenmayer
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Martin Maurer
- Department of Radiology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Corina Kim-Fuchs
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Daniel Candinas
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Vanessa Banz
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland.
| |
Collapse
|
47
|
Sibinga Mulder BG, Hendriks P, Baetens TR, van Erkel AR, van Rijswijk CSP, van der Meer RW, van de Velde CJH, Vahrmeijer AL, Mieog JSD, Burgmans MC. Quantitative margin assessment of radiofrequency ablation of a solitary colorectal hepatic metastasis using MIRADA RTx on CT scans: a feasibility study. BMC Med Imaging 2019; 19:71. [PMID: 31429708 PMCID: PMC6700773 DOI: 10.1186/s12880-019-0360-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2019] [Accepted: 07/23/2019] [Indexed: 12/12/2022] Open
Abstract
Background Compared to surgery, radiofrequency ablation(RFA) for colorectal liver metastasis(CRLM) is associated with higher local recurrence(LR) rates. A wide margin (at least 5 mm) is generally recommended to prevent LR, but the optimal method to assess ablation margins is yet to be established. The aim of our study was to evaluate the feasibility and reproducibility of CT-CT co-registration, using MIRADA software, in order to assess ablation margins of patients with CRLM. Methods In this retrospective study, pre- and post-ablation contrast-enhanced CT scans of 29 patients, treated with percutaneous RFA for a solitary CRLM, were co-registered. Co-registration was performed by two independent radiologist, based on venous structures in proximity to the tumor. Feasibility of CT-CT co-registration and inter-observer agreement for reproducibility and ablation margins was determined. Furthermore, the minimal ablation margin was compared with the occurrence of LR during follow-up. Results Co-registration was considered feasible in 18 patients (61% male, 63.1(±10.9) year), with a perfect inter-observer agreement for completeness of ablation: κ = 1.0(p < 0.001). And substantial inter-observer agreement for measurement of the minimal margin (≤ 0 mm, 1-5 mm, ≥ 5 mm): κ = 0.723(p-value < 0.001). LR occurred in eight of nine(88.9%) incompletely ablated CRLM and in one of the nine completely ablated CRLM(11.1%). Conclusion Co-registration using MIRADA is reproducible and potentially a valuable tool in defining technical success. Feasibility of co-registration of pre- and post-ablation CT scans is suboptimal if scans are not acquired concordantly. Co-registration may potentially aid in the prediction of LR after percutaneous ablation. Electronic supplementary material The online version of this article (10.1186/s12880-019-0360-2) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- B G Sibinga Mulder
- Department of Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - P Hendriks
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - T R Baetens
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - A R van Erkel
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - C S P van Rijswijk
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - R W van der Meer
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - C J H van de Velde
- Department of Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - A L Vahrmeijer
- Department of Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - J S D Mieog
- Department of Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - M C Burgmans
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
| |
Collapse
|
48
|
Liang H, Hou Y, Sun L, Li Q, Wei H, Feng Y. Supraglottic jet oxygenation and ventilation for obese patients under intravenous anesthesia during hysteroscopy: a randomized controlled clinical trial. BMC Anesthesiol 2019; 19:151. [PMID: 31409366 PMCID: PMC6693218 DOI: 10.1186/s12871-019-0821-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Accepted: 08/06/2019] [Indexed: 12/14/2022] Open
Abstract
Background Supraglottic jet oxygenation and ventilation (SJOV) can effectively maintain adequate oxygenation in patients with respiratory depression, even in apnea patients. However, there have been no randomized controlled clinical trials of SJOV in obese patients. This study investigated the efficacy and safety of SJOV using WEI Nasal Jet tube (WNJ) for obese patients who underwent hysteroscopy under intravenous anesthesia without endotracheal intubation. Methods A single-center, prospective, randomized controlled study was conducted. The obese patients receiving hysteroscopy under intravenous anesthesia were randomly divided into three groups: Control group maintaining oxygen supply via face masks (100% oxygen, flow at 6 L/min), the WNJ Oxygen Group with WNJ (100% oxygen, flow: 6 L/min) and the WNJ SJOV Group with SJOV via WNJ [Jet ventilator working parameters:100% oxygen supply, driving pressure (DP) 0.1 MPa, respiratory rate; (RR): 15 bpm, I/E; ratio 1:1.5]. SpO2, PETCO2, BP, HR, ECG and BIS were continuously monitored during anesthesia. Two-Diameter Method was deployed to measure cross sectional area of the gastric antrum (CSA-GA) by ultrasound before and after SJOV in the WNJ SJOV Group. Episodes of SpO2 less than 95%, PETCO2 less than 10 mmHg, depth of WNJ placement and measured CSA-GA before and after jet ventilation in the WNJ SJOV Group during the operation were recorded. The other adverse events were collected as well. Results A total of 102 patients were enrolled, with two patients excluded. Demographic characteristics were similar among the three groups. Compared with the Control Group, the incidence of PETCO2 < 10 mmHg, SpO2 < 95% in the WNJ SJOV group dropped from 36 to 9% (P = 0.009),from 33 to 6% (P = 0.006) respectively,and the application rate of jaw-lift decreased from 33 to 3% (P = 0.001), and the total percentage of adverse events decreased from 36 to 12% (P = 0.004). Compared with the WNJ Oxygen Group, the use of SJOV via WNJ significantly decreased episodes of SpO2 < 95% from 27 to 6% (P = 0.023), PETCO2 < 10 mmHg from 33 to 9% (P = 0.017), respectively. Depth of WNJ placement was about 12.34 cm in WNJ SJOV Group. There was no significantly difference of CSA-GA before and after SJOV in the WNJ SJOV Group (P = 0.234). There were no obvious cases of nasal bleeding in all the three groups. Conclusions SJOV can effectively and safely maintain adequate oxygenation in obese patients under intravenous anesthesia without intubation during hysteroscopy. This efficient oxygenation may be mainly attributed to supplies of high concentration oxygenation to the supraglottic area, and the high pressure jet pulse providing effective ventilation. Although the nasal airway tube supporting collapsed airway by WNJ also plays a role. SJOV doesn’t seem to increase gastric distension and the risk of aspiration. SJOV can improve the safety of surgery by reducing the incidence of the intraoperative involuntary limbs swing, hip twist and cough. Trial registration Chinese Clinical Trial Registry. Registration number, ChiCTR1800017028, registered on July 9, 2018.
Collapse
Affiliation(s)
- Hansheng Liang
- Department of Anesthesiology, Peking University People's Hospital, Beijing100044, Beijing, China
| | - Yuantao Hou
- Department of Anesthesiology, Peking University People's Hospital, Beijing100044, Beijing, China
| | - Liang Sun
- Department of Anesthesiology, Peking University People's Hospital, Beijing100044, Beijing, China
| | - Qingyue Li
- Department of Anesthesiology, Peking University People's Hospital, Beijing100044, Beijing, China
| | - Huafeng Wei
- Department of Anesthesiology and Critical Care, Hospital of the University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Yi Feng
- Department of Anesthesiology, Peking University People's Hospital, Beijing100044, Beijing, China.
| |
Collapse
|
49
|
Heinrich F, Joeres F, Lawonn K, Hansen C. Comparison of Projective Augmented Reality Concepts to Support Medical Needle Insertion. IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS 2019; 25:2157-2167. [PMID: 30892210 DOI: 10.1109/tvcg.2019.2903942] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Augmented reality (AR) is a promising tool to improve instrument navigation in needle-based interventions. Limited research has been conducted regarding suitable navigation visualizations. In this work, three navigation concepts based on existing approaches were compared in a user study using a projective AR setup. Each concept was implemented with three different scales for accuracy-to-color mapping and two methods of navigation indicator scaling. Participants were asked to perform simulated needle insertion tasks with each of the resulting 18 prototypes. Insertion angle and insertion depth accuracies were measured and analyzed, as well as task completion time and participants' subjectively perceived task difficulty. Results show a clear ranking of visualization concepts across variables. Less consistent results were obtained for the color and indicator scaling factors. Results suggest that logarithmic indicator scaling achieved better accuracy, but participants perceived it to be more difficult than linear scaling. With specific results for angle and depth accuracy, our study contributes to the future composition of improved navigation support and systems for precise needle insertion or similar applications.
Collapse
|
50
|
Initial experience with irreversible electroporation of liver tumours. Eur J Radiol Open 2019; 6:62-67. [PMID: 30723754 PMCID: PMC6351588 DOI: 10.1016/j.ejro.2019.01.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Revised: 01/14/2019] [Accepted: 01/17/2019] [Indexed: 12/18/2022] Open
Abstract
Introduction Thermal ablation of liver tumours is an established technique used in selected patients with relatively small tumours that can be ablated with margin. Thermal ablation methods are not advisable near larger bile ducts that are sensitive to thermal injury causing strictures and severe morbidity. Irreversible electroporation (IRE) has the possibility to treat these tumours without harming the bile tree. The method is relatively new and has been proven to be feasible and safe with promising oncological results. Methods 50 treatments were performed on 42 patients that were not resectable or treatable by thermal ablation (12 women and 30 men) with 59 tumours in total. 51% were colorectal cancer liver metastases (CRCLM) and 34% were hepatocellular carcinomas (HCC). 70% of the treatments were performed using stereotactic CT-guidance for needle placement. Results 81% of the treatments were performed with initial success. All patients with missed ablations were re-treated. Local recurrence rate at 3 months was 3% and 37% at one year. The complication rate was low with 2 patients having major complications (Clavien-Dindo grade 3b-5) and without 30-day mortality. Conclusion IRE is safe for treating tumours not suitable for thermal ablation with 63% of patients being without local recurrence after one year in a group of patients with tumours deemed unresectable. IRE has a role in the treatment of unresectable liver tumours close to heat-sensitive structures not suitable for thermal ablation. Level of Evidence: Level 4, Case Series.
Collapse
|