1
|
McGrath S, Shen YJ, Aragaki M, Motooka Y, Koga T, Gregor A, Bernards N, Cherin E, Demore CEM, Yasufuku K, Matsuura N. Imaging Microbubbles With Contrast-Enhanced Endobronchial Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:28-38. [PMID: 37813701 DOI: 10.1016/j.ultrasmedbio.2023.08.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 08/02/2023] [Accepted: 08/28/2023] [Indexed: 10/11/2023]
Abstract
OBJECTIVE Endobronchial ultrasound (EBUS) is commonly used to guide transbronchial needle biopsies for the staging of lymph nodes in non-small cell lung cancer patients. Although contrast-enhanced ultrasound (CEUS) and microbubbles (MBs) can improve the diagnostic accuracy in tumors, the ability of contrast-enhanced EBUS (CE-EBUS) to image MBs has not yet been comprehensively evaluated. In this study, we assessed the ability of a CE-EBUS system (Olympus EU-ME2 PREMIER and BF-UC180F bronchoscope) to detect laboratory-synthesized MBs in comparison to clinical (Toshiba Aplio SSA-790A) and pre-clinical (VisualSonics Vevo 2100) CEUS systems in vitro and in vivo, respectively. METHODS Agar flow phantoms and reference tissue were used to assess CE-EBUS MB imaging in vitro, and A549 tumor-bearing athymic nude and AE17-OVA tumor-bearing C57BL/6 mice were used to assess MB detectability and perfusion in vivo, respectively. RESULTS Results revealed that despite the lower sensitivity of CE-EBUS to MB concentration in comparison to clinical CEUS, CE-EBUS yielded a similar contrast-to-tissue ratio (CTR) in vitro of 28.9 ± 4.5 dB for CE-EBUS, compared with 29.7 ± 2.6 dB for clinical CEUS (p < 0.05). In vivo, CE-EBUS generated a perfusion curve highly correlated with that obtained with the pre-clinical CEUS system (Pearson correlation coefficient = 0.927, p < 0.05). Moreover, CE-EBUS yielded a CTR 2.7 times higher than that obtained with the pre-clinical ultrasound system. CONCLUSION These findings together suggest that CE-EBUS can perform contrast imaging comparable to that produced by commercial pre-clinical and clinical ultrasound systems, with potential for clinical characterization of mediastinal lymph nodes in lung cancer patients.
Collapse
Affiliation(s)
- Sean McGrath
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Yu-Jack Shen
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Masato Aragaki
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Yamato Motooka
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Takamasa Koga
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Alexander Gregor
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Nicholas Bernards
- Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Emmanuel Cherin
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Christine E M Demore
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada; Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
| | - Kazuhiro Yasufuku
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada; Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Naomi Matsuura
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada; Department of Materials Science & Engineering, University of Toronto, Toronto, ON, Canada; Department of Medical Imaging, University of Toronto, Toronto, ON, Canada.
| |
Collapse
|
2
|
Tanniche I, Behkam B. Engineered live bacteria as disease detection and diagnosis tools. J Biol Eng 2023; 17:65. [PMID: 37875910 PMCID: PMC10598922 DOI: 10.1186/s13036-023-00379-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 09/18/2023] [Indexed: 10/26/2023] Open
Abstract
Sensitive and minimally invasive medical diagnostics are essential to the early detection of diseases, monitoring their progression and response to treatment. Engineered bacteria as live sensors are being developed as a new class of biosensors for sensitive, robust, noninvasive, and in situ detection of disease onset at low cost. Akin to microrobotic systems, a combination of simple genetic rules, basic logic gates, and complex synthetic bioengineering principles are used to program bacterial vectors as living machines for detecting biomarkers of diseases, some of which cannot be detected with other sensing technologies. Bacterial whole-cell biosensors (BWCBs) can have wide-ranging functions from detection only, to detection and recording, to closed-loop detection-regulated treatment. In this review article, we first summarize the unique benefits of bacteria as living sensors. We then describe the different bacteria-based diagnosis approaches and provide examples of diagnosing various diseases and disorders. We also discuss the use of bacteria as imaging vectors for disease detection and image-guided surgery. We conclude by highlighting current challenges and opportunities for further exploration toward clinical translation of these bacteria-based systems.
Collapse
Affiliation(s)
- Imen Tanniche
- Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Bahareh Behkam
- Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA, 24061, USA.
- School of Biomedical Engineered and Sciences, Virginia Tech, Blacksburg, VA, 24061, USA.
- Center for Engineered Health, Institute for Critical Technology and Applied Science, Virginia Tech, Blacksburg, VA, 24061, USA.
| |
Collapse
|
3
|
Navarro-Becerra JA, Castillo JI, Di Ruzza F, Borden MA. Monodispersity Increases Adhesion Efficiency and Specificity for Ultrasound-Targeted Microbubbles. ACS Biomater Sci Eng 2023; 9:991-1001. [PMID: 36153974 DOI: 10.1021/acsbiomaterials.2c00528] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Ultrasound molecular imaging with targeted microbubbles (MBs) can be used to noninvasively diagnose, monitor, and study the progression of different endothelial-associated diseases. Acoustic radiation force (Frad) can initiate and enhance MB adhesion at the target site. The goal of this study was to elucidate the effects of various MB parameters on Frad targeting. Monodisperse or polydisperse MBs with the immune-stealth cloaked (buried)-ligand architecture were conjugated with targeting RGD or nonspecific isotype control RAD peptides and then pumped through an αvβ3 integrin-coated microvessel phantom at a wall shear stress of 3.5 dyn/cm2. Targeting was assessed by measuring MB attachment for varying Frad time and frequency, as well as MB concentration and size distribution. We first confirmed that primary Frad is necessary to target the cloaked-ligand MBs. MB targeting increased monotonically with αvβ3 integrin density and Frad time. MB attachment and, to a lesser extent specificity, also increased when driven by Frad near resonance. MB targeting increased with MB concentration, although a shift in behavior was observed with increasing MB-MB interactions and aggregations forming from secondary Frad effects as MB concentration was increased. These secondary Frad effects reduced targeting specificity. Finally, after having validated our approach by testing different parameters with the appropriate controls, we then determined the effects of monodispersity on adhesion efficiency and specific targeting. We observed that both MB targeting efficiency and specificity were greatly enhanced for monodisperse vs polydisperse MBs. Analysis of videomicroscopy images indicated that secondary Frad effects may have disproportionally inhibited targeting of polydisperse MBs. In conclusion, our in vitro results indicate that monodisperse MBs driven near resonance and at a low concentration (∼106 MB/mL) can be used to maximize the adhesion efficiency (up to 88%) and specificity of RGD-MB targeting.
Collapse
Affiliation(s)
- J Angel Navarro-Becerra
- Mechanical Engineering Department, University of Colorado Boulder, Boulder, Colorado 80309-0427, United States
| | - Jair I Castillo
- Biomedical Engineering Program, University of Colorado Boulder, Boulder, Colorado 80309-0427, United States
| | - Federico Di Ruzza
- Biomedical Engineering Program, University of Colorado Boulder, Boulder, Colorado 80309-0427, United States.,Chemical Science and Technology Department, University of Rome Tor Vergata, Roma 00133, Italy
| | - Mark A Borden
- Mechanical Engineering Department, University of Colorado Boulder, Boulder, Colorado 80309-0427, United States.,Biomedical Engineering Program, University of Colorado Boulder, Boulder, Colorado 80309-0427, United States
| |
Collapse
|
4
|
Zeng W, Yue X, Dai Z. Ultrasound contrast agents from microbubbles to biogenic gas vesicles. MEDICAL REVIEW (2021) 2023; 3:31-48. [PMID: 37724107 PMCID: PMC10471104 DOI: 10.1515/mr-2022-0020] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Accepted: 09/11/2022] [Indexed: 09/20/2023]
Abstract
Microbubbles have been the earliest and most widely used ultrasound contrast agents by virtue of their unique features: such as non-toxicity, intravenous injectability, ability to cross the pulmonary capillary bed, and significant enhancement of echo signals for the duration of the examination, resulting in essential preclinical and clinical applications. The use of microbubbles functionalized with targeting ligands to bind to specific targets in the bloodstream has further enabled ultrasound molecular imaging. Nevertheless, it is very challenging to utilize targeted microbubbles for molecular imaging of extravascular targets due to their size. A series of acoustic nanomaterials have been developed for breaking free from this constraint. Especially, biogenic gas vesicles, gas-filled protein nanostructures from microorganisms, were engineered as the first biomolecular ultrasound contrast agents, opening the door for more direct visualization of cellular and molecular function by ultrasound imaging. The ordered protein shell structure and unique gas filling mechanism of biogenic gas vesicles endow them with excellent stability and attractive acoustic responses. What's more, their genetic encodability enables them to act as acoustic reporter genes. This article reviews the upgrading progresses of ultrasound contrast agents from microbubbles to biogenic gas vesicles, and the opportunities and challenges for the commercial and clinical translation of the nascent field of biomolecular ultrasound.
Collapse
Affiliation(s)
- Wenlong Zeng
- Department of Biomedical Engineering, College of Future Technology, Peking University, Beijing, China
| | - Xiuli Yue
- School of Environment, Harbin Institute of Technology, Harbin, China
| | - Zhifei Dai
- Department of Biomedical Engineering, College of Future Technology, Peking University, Beijing, China
| |
Collapse
|
5
|
Kierski TM, Walmer RW, Tsuruta JK, Yin J, Chérin E, Foster FS, Demore CEM, Newsome IG, Pinton GF, Dayton PA. Acoustic Molecular Imaging Beyond the Diffraction Limit In Vivo. IEEE OPEN JOURNAL OF ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 2:237-249. [PMID: 38125957 PMCID: PMC10732349 DOI: 10.1109/ojuffc.2022.3212342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
Ultrasound molecular imaging (USMI) is a technique used to noninvasively estimate the distribution of molecular markers in vivo by imaging microbubble contrast agents (MCAs) that have been modified to target receptors of interest on the vascular endothelium. USMI is especially relevant for preclinical and clinical cancer research and has been used to predict tumor malignancy and response to treatment. In the last decade, methods that improve the resolution of contrast-enhanced ultrasound by an order of magnitude and allow researchers to noninvasively image individual capillaries have emerged. However, these approaches do not translate directly to molecular imaging. In this work, we demonstrate super-resolution visualization of biomarker expression in vivo using superharmonic ultrasound imaging (SpHI) with dual-frequency transducers, targeted contrast agents, and localization microscopy processing. We validate and optimize the proposed method in vitro using concurrent optical and ultrasound microscopy and a microvessel phantom. With the same technique, we perform a proof-of-concept experiment in vivo in a rat fibrosarcoma model and create maps of biomarker expression co-registered with images of microvasculature. From these images, we measure a resolution of 23 μm, a nearly fivefold improvement in resolution compared to previous diffraction-limited molecular imaging studies.
Collapse
Affiliation(s)
- Thomas M Kierski
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| | - Rachel W Walmer
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| | - James K Tsuruta
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| | - Jianhua Yin
- Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada
| | | | - F Stuart Foster
- Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, ON M4N 3M5, Canada
| | - Christine E M Demore
- Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, ON M4N 3M5, Canada
| | - Isabel G Newsome
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| | - Gianmarco F Pinton
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| |
Collapse
|
6
|
Li M, Beaumont N, Ma C, Rojas J, Vu T, Harlacher M, O'Connell G, Gessner RC, Kilian H, Kasatkina L, Chen Y, Huang Q, Shen X, Lovell JF, Verkhusha VV, Czernuszewicz T, Yao J. Three-Dimensional Deep-Tissue Functional and Molecular Imaging by Integrated Photoacoustic, Ultrasound, and Angiographic Tomography (PAUSAT). IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:2704-2714. [PMID: 35442884 PMCID: PMC9563100 DOI: 10.1109/tmi.2022.3168859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Non-invasive small-animal imaging technologies, such as optical imaging, magnetic resonance imaging and x -ray computed tomography, have enabled researchers to study normal biological phenomena or disease progression in their native conditions. However, existing small-animal imaging technologies often lack either the penetration capability for interrogating deep tissues (e.g., optical microscopy), or the functional and molecular sensitivity for tracking specific activities (e.g., magnetic resonance imaging). To achieve functional and molecular imaging in deep tissues, we have developed an integrated photoacoustic, ultrasound and acoustic angiographic tomography (PAUSAT) system by seamlessly combining light and ultrasound. PAUSAT can perform three imaging modes simultaneously with complementary contrast: high-frequency B-mode ultrasound imaging of tissue morphology, microbubble-enabled acoustic angiography of tissue vasculature, and multi-spectral photoacoustic imaging of molecular probes. PAUSAT can provide three-dimensional (3D) multi-contrast images that are co-registered, with high spatial resolutions at large depths. Using PAUSAT, we performed proof-of-concept in vivo experiments on various small animal models: monitoring longitudinal development of placenta and embryo during mouse pregnancy, tracking biodistribution and metabolism of near-infrared organic dye on the whole-body scale, and detecting breast tumor expressing genetically-encoded photoswitchable phytochromes. These results have collectively demonstrated that PAUSAT has broad applicability in biomedical research, providing comprehensive structural, functional, and molecular imaging of small animal models.
Collapse
|
7
|
Soysal U, Azevedo PN, Bureau F, Aubry A, Carvalho MS, Pessoa ACSN, Torre LGDL, Couture O, Tourin A, Fink M, Tabeling P. Freeze-Dried Microfluidic Monodisperse Microbubbles as a New Generation of Ultrasound Contrast Agents. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1484-1495. [PMID: 35568594 DOI: 10.1016/j.ultrasmedbio.2022.03.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 03/10/2022] [Accepted: 03/17/2022] [Indexed: 06/15/2023]
Abstract
We succeeded in freeze-drying monodisperse microbubbles without degrading their performance, that is, their monodispersity in size and echogenicity. We used microfluidic technology to generate cryoprotected highly monodisperse microbubbles (coefficient of variation [CV] <5%). By using a novel retrieval technique, we were able to freeze-dry the microbubbles and resuspend them without degradation, that is, keeping their size distribution narrow (CV <6%). Acoustic characterization performed in two geometries (a centimetric cell and a millichannel) revealed that the resuspended bubbles conserved the sharpness of the backscattered resonance peak, leading to CVs ranging between 5% and 10%, depending on the geometry. As currently observed with monodisperse bubbles, the peak amplitudes are one order of magnitude higher than those of commercial ultrasound contrast agents. Our work thus solves the question of storage and transportation of highly monodisperse bubbles. This work might open pathways toward novel clinical non-invasive measurements, such as local pressure, impossible to carry out with the existing commercial ultrasound contrast agents.
Collapse
Affiliation(s)
- Ugur Soysal
- Microfluidique, MEMS et Nanostructures, Institut Pierre Gilles de Gennes, ESPCI Paris, Université PSL, CNRS, France.
| | - Pedro N Azevedo
- Microfluidique, MEMS et Nanostructures, Institut Pierre Gilles de Gennes, ESPCI Paris, Université PSL, CNRS, France; Institut Langevin, ESPCI Paris, Université PSL, CNRS, France; Department of Mechanical Engineering, PUC-Rio, Brazil
| | - Flavien Bureau
- Institut Langevin, ESPCI Paris, Université PSL, CNRS, France
| | - Alexandre Aubry
- Institut Langevin, ESPCI Paris, Université PSL, CNRS, France
| | | | | | | | | | - Arnaud Tourin
- Institut Langevin, ESPCI Paris, Université PSL, CNRS, France
| | - Mathias Fink
- Institut Langevin, ESPCI Paris, Université PSL, CNRS, France
| | - Patrick Tabeling
- Microfluidique, MEMS et Nanostructures, Institut Pierre Gilles de Gennes, ESPCI Paris, Université PSL, CNRS, France
| |
Collapse
|
8
|
Le DQ, Papadopoulou V, Dayton PA. Effect of Acoustic Parameters and Microbubble Concentration on the Likelihood of Encapsulated Microbubble Coalescence. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2980-2989. [PMID: 34344561 PMCID: PMC8547186 DOI: 10.1016/j.ultrasmedbio.2021.06.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/23/2021] [Accepted: 06/30/2021] [Indexed: 06/13/2023]
Abstract
Microbubble contrast agents are commonly used for therapeutic and diagnostic imaging applications. Under certain conditions, these contrast agents can coalesce on ultrasound application and form larger bubbles than the initial population. The formation of large microbubbles potentially influences therapeutic outcomes and imaging quality. We studied clinically relevant ultrasound parameters related to low-pressure therapy and contrast-enhanced ultrasound imaging to determine their effect on microbubble coalescence and subsequent changes in microbubble size distributions in vitro. Results indicate that therapeutic ultrasound at low frequencies, moderate pressures and high duty cycles are capable of forming bubbles greater than two times larger than the initial bubble distribution. Furthermore, acoustic parameters related to contrast-enhanced ultrasound imaging that are at higher frequency, low-pressure and low-duty cycle exhibit no statistically significant changes in bubble diameter, suggesting that standard contrast ultrasound imaging does not cause coalescence. Overall, this work suggests that the microbubble coalescence phenomenon can readily occur at acoustic parameters used in therapeutic ultrasound, generating bubbles much larger than those found in commercial contrast agents, although coalescence is unlikely to be significant in diagnostic contrast-enhanced ultrasound imaging. This observation warrants further expansion of parameter ranges and investigation of resulting effects.
Collapse
Affiliation(s)
- David Q Le
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Virginie Papadopoulou
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA.
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| |
Collapse
|
9
|
Abstract
In recent years, minuscule gas bubbles called bulk nanobubbles (BNBs) have drawn increasing attention due to their unique properties and broad applicability in various technological fields, such as biomedical engineering, water treatment, and nanomaterials. However, questions remain regarding the stability and behavior of BNBs. In the present work, BNBs were generated in water using a gas-liquid mixing method. NB analysis was performed using a nanoparticle tracking analysis (NTA) method to investigate the coarsening behavior of BNBs in water over time. The diameters of the BNBs increased, and their cubic radii increased linearly (r3 ~ t) over time. While the concentration of BNBs decreased, the total volume of BNBs remained the same. The size distribution of the BNBs broadened, and the concentration of larger BNBs increased over time. These results indicate that relatively small BNBs disappeared due to dissolution and larger BNBs grew through mass transfer between BNBs instead of coalescence. In other words, BNBs underwent Ostwald ripening: gas molecules from smaller BNBs diffused through the continuous phase to be absorbed into larger BNBs.
Collapse
|
10
|
van Elburg B, Collado-Lara G, Bruggert GW, Segers T, Versluis M, Lajoinie G. Feedback-controlled microbubble generator producing one million monodisperse bubbles per second. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:035110. [PMID: 33820052 DOI: 10.1063/5.0032140] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 02/15/2021] [Indexed: 06/12/2023]
Abstract
Monodisperse lipid-coated microbubbles are a promising route to unlock the full potential of ultrasound contrast agents for medical diagnosis and therapy. Here, we present a stand-alone lab-on-a-chip instrument that allows microbubbles to be formed with high monodispersity at high production rates. Key to maintaining a long-term stable, controlled, and safe operation of the microfluidic device with full control over the output size distribution is an optical transmission-based measurement technique that provides real-time information on the production rate and bubble size. We feed the data into a feedback loop and demonstrate that this system can control the on-chip bubble radius (2.5 μm-20 μm) and the production rate up to 106 bubbles/s. The freshly formed phospholipid-coated bubbles stabilize after their formation to a size approximately two times smaller than their initial on-chip bubble size without loss of monodispersity. The feedback control technique allows for full control over the size distribution of the agent and can aid the development of microfluidic platforms operated by non-specialist end users.
Collapse
Affiliation(s)
- Benjamin van Elburg
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Gonzalo Collado-Lara
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Gert-Wim Bruggert
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Tim Segers
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Michel Versluis
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Guillaume Lajoinie
- Physics of Fluids Group, Technical Medical (TechMed) Center and MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| |
Collapse
|
11
|
|
12
|
Helbert A, Gaud E, Segers T, Botteron C, Frinking P, Jeannot V. Monodisperse versus Polydisperse Ultrasound Contrast Agents: In Vivo Sensitivity and safety in Rat and Pig. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3339-3352. [PMID: 33008649 DOI: 10.1016/j.ultrasmedbio.2020.07.031] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 07/24/2020] [Accepted: 07/30/2020] [Indexed: 05/21/2023]
Abstract
Recent advances in the field of monodisperse microbubble synthesis by flow focusing allow for the production of foam-free, highly concentrated and monodisperse lipid-coated microbubble suspensions. It has been found that in vitro, such monodisperse ultrasound contrast agents (UCAs) improve the sensitivity of contrast-enhanced ultrasound imaging. Here, we present the first in vivo study in the left ventricle of rat and pig with this new monodisperse bubble agent. We systematically characterize the acoustic sensitivity and safety of the agent at an imaging frequency of 2.5 MHz as compared with three commercial polydisperse UCAs (SonoVue/Lumason, Definity/Luminity and Optison) and one research-grade polydisperse agent with the same shell composition as the monodisperse bubbles. The monodisperse microbubbles, which had a diameter of 4.2 μm, crossed the pulmonary vasculature, and their echo signal could be measured at least as long as that of the polydisperse UCAs, indicating that microfluidically formed monodisperse microbubbles are stable in vivo. Furthermore, it was found that the sensitivity of the monodisperse agent, expressed as the mean echo power per injected bubble, was at least 10 times higher than that of the polydisperse UCAs. Finally, the safety profile of the monodisperse microbubble suspension was evaluated by injecting 400 and 2000 times the imaging dose, and neither physiologic nor pathologic changes were found, which is a first indication that monodisperse lipid-coated microbubbles formed by flow focusing are safe for in vivo use. The more uniform acoustic response and corresponding increased imaging sensitivity of the monodisperse agent may boost emerging applications of microbubbles and ultrasound such as molecular imaging and therapy.
Collapse
Affiliation(s)
- Alexandre Helbert
- Bracco Suisse S.A., Route de la Galaise 31, 1228 Plan-les-Ouates, Switzerland
| | - Emmanuel Gaud
- Bracco Suisse S.A., Route de la Galaise 31, 1228 Plan-les-Ouates, Switzerland
| | - Tim Segers
- Physics of Fluids Group, MESA + Institute for Nanotechnology, Technical Medical (TechMed) Center, University of Twente, Enschede, The Netherlands; Former employee of Bracco Suisse S.A
| | | | | | - Victor Jeannot
- Bracco Suisse S.A., Route de la Galaise 31, 1228 Plan-les-Ouates, Switzerland.
| |
Collapse
|
13
|
Newsome IG, Dayton PA. Visualization of Microvascular Angiogenesis Using Dual-Frequency Contrast-Enhanced Acoustic Angiography: A Review. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2625-2635. [PMID: 32703659 PMCID: PMC7608693 DOI: 10.1016/j.ultrasmedbio.2020.06.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 05/25/2020] [Accepted: 06/14/2020] [Indexed: 05/07/2023]
Abstract
Cancerous tumor growth is associated with the development of tortuous, chaotic microvasculature, and this aberrant microvascular morphology can act as a biomarker of malignant disease. Acoustic angiography is a contrast-enhanced ultrasound technique that relies on superharmonic imaging to form high-resolution 3-D maps of the microvasculature. To date, acoustic angiography has been performed with dual-element transducers that can achieve high contrast-to-tissue ratio and resolution in pre-clinical small animal models. In this review, we first describe the development of acoustic angiography, including the principle, transducer design, and optimization of superharmonic imaging techniques. We then detail several preclinical applications of this microvascular imaging method, as well as the current and future development of acoustic angiography as a pre-clinical and clinical diagnostic tool.
Collapse
Affiliation(s)
- Isabel G Newsome
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA.
| |
Collapse
|
14
|
Goel L, Wu H, Kim H, Zhang B, Kim J, Dayton PA, Xu Z, Jiang X. Examining the Influence of Low-Dose Tissue Plasminogen Activator on Microbubble-Mediated Forward-Viewing Intravascular Sonothrombolysis. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1698-1706. [PMID: 32389332 PMCID: PMC7293952 DOI: 10.1016/j.ultrasmedbio.2020.03.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 02/01/2020] [Accepted: 03/11/2020] [Indexed: 05/04/2023]
Abstract
Previous work revealed that a forward-viewing intravascular (FVI) transducer can be used for microbubble (MB)-mediated sonothrombolysis and that the clot lysis was dependent on MB concentration. This study examined the effects of combining tissue plasminogen activator (tPA) with MB-mediated FVI sonothrombolysis. In vitro clot lysis and passive cavitation experiments were conducted to study the effect of low-dose tPA in FVI sonothrombolysis with varying MB concentrations. Enhanced FVI sonothrombolysis was observed in cases in which ultrasound (US) was combined with tPA or MBs compared with control, tPA alone or US alone. The lysis rate of US + tPA + MBs was improved by up to 130%, 31% and 8% for MB concentrations of 106, 107 and 108 MBs/mL, respectively, compared with MBs + US alone. Changes in stable and inertial cavitation doses were observed, corresponding to changes in clot lysis in MB-mediated FVI sonothrombolysis with and without tPA.
Collapse
Affiliation(s)
- Leela Goel
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA; Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Raleigh, North Carolina, USA
| | - Huaiyu Wu
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Howuk Kim
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Bohua Zhang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Jinwook Kim
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Raleigh, North Carolina, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Raleigh, North Carolina, USA
| | - Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Xiaoning Jiang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA.
| |
Collapse
|
15
|
Frinking P, Segers T, Luan Y, Tranquart F. Three Decades of Ultrasound Contrast Agents: A Review of the Past, Present and Future Improvements. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:892-908. [PMID: 31941587 DOI: 10.1016/j.ultrasmedbio.2019.12.008] [Citation(s) in RCA: 131] [Impact Index Per Article: 32.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 12/05/2019] [Accepted: 12/06/2019] [Indexed: 06/10/2023]
Abstract
Initial reports from the 1960s describing the observations of ultrasound contrast enhancement by tiny gaseous bubbles during echocardiographic examinations prompted the development of the first ultrasound contrast agent in the 1980s. Current commercial contrast agents for echography, such as Definity, Optison, Sonazoid and SonoVue, have proven to be successful in a variety of on- and off-label clinical indications. Whereas contrast-specific technology has seen dramatic progress after the introduction of the first approved agents in the 1990s, successful clinical translation of new developments has been limited during the same period, while understanding of microbubble physical, chemical and biologic behavior has improved substantially. It is expected that for a successful development of future opportunities, such as ultrasound molecular imaging and therapeutic applications using microbubbles, new creative developments in microbubble engineering and production dedicated to further optimizing microbubble performance are required, and that they cannot rely on bubble technology developed more than 3 decades ago.
Collapse
Affiliation(s)
- Peter Frinking
- Tide Microfluidics, Capitool 41, Enschede, The Netherlands.
| | - Tim Segers
- Physics of Fluids group, University of Twente, Enschede, The Netherlands
| | - Ying Luan
- R&D Pharmaceutical Diagnostics, General Electric Healthcare, Amersham, UK
| | - François Tranquart
- R&D Pharmaceutical Diagnostics, General Electric Healthcare, Amersham, UK
| |
Collapse
|
16
|
Zhou LQ, Li P, Cui XW, Dietrich CF. Ultrasound nanotheranostics in fighting cancer: Advances and prospects. Cancer Lett 2020; 470:204-219. [PMID: 31790760 DOI: 10.1016/j.canlet.2019.11.034] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Revised: 11/25/2019] [Accepted: 11/26/2019] [Indexed: 12/24/2022]
|
17
|
Newsome IG, Kierski TM, Dayton PA. Assessment of the Superharmonic Response of Microbubble Contrast Agents for Acoustic Angiography as a Function of Microbubble Parameters. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2515-2524. [PMID: 31174922 PMCID: PMC7202402 DOI: 10.1016/j.ultrasmedbio.2019.04.027] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 04/25/2019] [Accepted: 04/30/2019] [Indexed: 05/07/2023]
Abstract
Acoustic angiography is a superharmonic contrast-enhanced ultrasound imaging technique that enables 3-D high-resolution microvascular visualization. This technique utilizes a dual-frequency imaging strategy, transmitting at a low frequency and receiving at a higher frequency, to detect high-frequency contrast agent signatures and separate them from tissue background. Prior studies have illustrated differences in microbubble scatter dependent on microbubble size and composition; however, most previously reported data have utilized a relatively narrow frequency bandwidth centered around the excitation frequency. To date, a comprehensive study of isolated microbubble superharmonic responses with a broadband dual-frequency system has not been performed. Here, the superharmonic signal production of 14 contrast agents with various gas cores, shell compositions, and bubble diameters at mechanical indices of 0.2 to 1.2 was evaluated using a transmit 4 MHz, receive 25 MHz configuration. Results indicate that perfluorocarbon cores or lipid shells with 18- or 20-carbon acyl chains produce more superharmonic signal than sulfur hexafluoride cores or lipid shells with 16-carbon acyl chains, respectively. As microbubble diameter increases from 1 to 4 µm, superharmonic generation decreases. In a comparison of two clinical agents, Definity and Optison, and one preclinical agent, Micromarker, Optison produced the least superharmonic signal. Overall, this work suggests that microbubbles around 1 μm in diameter with perfluorocarbon cores and longer-chained lipid shells perform best for superharmonic imaging at 4 MHz. Studies have found that microbubble superharmonic response follows trends different from those described in prior studies using a narrower frequency bandwidth centered around the excitation frequency. Future work will apply these results in vivo to optimize the sensitivity of acoustic angiography.
Collapse
Affiliation(s)
- Isabel G Newsome
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Thomas M Kierski
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA.
| |
Collapse
|
18
|
Hall RL, Juan-Sing ZD, Hoyt K, Sirsi SR. Formulation and Characterization of Chemically Cross-linked Microbubble Clusters. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:10977-10986. [PMID: 31310715 PMCID: PMC7061884 DOI: 10.1021/acs.langmuir.9b00475] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The purpose of this study is to introduce a new concept of chemically cross-linked microbubble clusters (CCMCs), which are individual microbubble ultrasound contrast agents (UCAs) physically tethered together. We demonstrate a facile means of their production, characterize their size and stability, and describe how they can potentially be used in biomedical applications. By tethering UCAs together into CCMCs, we propose that novel methods of ultrasound mediated imaging and therapy can be developed through unique interbubble interactions in an ultrasound field. One of the major challenges in generating CCMCs is controlling aggregate sizes and maintaining stability against Ostwald ripening and coalescence. In this study, we demonstrate that chemically cross-linked microbubble clusters can produce small (<10 μm) quasi-stable complexes that slowly fuse into bubbles with individual gas cores. Furthermore, we demonstrate that this process can be driven with low-intensity ultrasound pulses, enabling a rapid fusion of clusters which could potentially be used to develop novel ultrasound contrast imaging and drug delivery strategies in future studies. The development of novel microbubble clusters presents a simple yet robust process for generating novel UCAs with a design that could allow for more versatility in contrast-enhanced ultrasound (CEUS), molecular imaging, and drug delivery applications. Additionally, microbubble clustering is a unique way to control size, shell, and gas compositions that can be used to study bubble ripening and coalescence in a highly controlled environment or study the behavior of mixed-microbubble populations.
Collapse
Affiliation(s)
- Ronald L. Hall
- University of Texas at Dallas, Richardson, Texas, 75080, United States
| | | | - Kenneth Hoyt
- University of Texas at Dallas, Richardson, Texas, 75080, United States
- University of Texas Southwestern, Dallas, Texas, 75390, United States
| | - Shashank R. Sirsi
- University of Texas at Dallas, Richardson, Texas, 75080, United States
- University of Texas Southwestern, Dallas, Texas, 75390, United States
| |
Collapse
|
19
|
Gormley CA, Keenan BJ, Buczek-Thomas JA, Pessoa ACSN, Xu J, Monti F, Tabeling P, Holt RG, Nagy JO, Wong JY. Fibrin-Targeted Polymerized Shell Microbubbles as Potential Theranostic Agents for Surgical Adhesions. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:10061-10067. [PMID: 30681875 PMCID: PMC6767917 DOI: 10.1021/acs.langmuir.8b03692] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
The development of new therapies for surgical adhesions has proven to be difficult as there is no consistently effective way to assess treatment efficacy in clinical trials without performing a second surgery, which can result in additional adhesions. We have developed lipid microbubble formulations that use a short peptide sequence, CREKA, to target fibrin, the molecule that forms nascent adhesions. These targeted polymerized shell microbubbles (PSMs) are designed to allow ultrasound imaging of early adhesions for diagnostic purposes and for evaluating the success of potential treatments in clinical trials while acting as a possible treatment. In this study, we show that CREKA-targeted microbubbles preferentially bind fibrin over fibrinogen and are stable for long periods of time (∼48 h), that these bound microbubbles can be visualized by ultrasound, and that neither these lipid-based bubbles nor their diagnostic-ultrasound-induced vibrations damage mesothelial cells in vitro. Moreover, these bubbles show the potential to identify adhesionlike fibrin formations and may hold promise in blocking or breaking up fibrin formations in vivo.
Collapse
Affiliation(s)
- Catherine A. Gormley
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, Massachusetts 02215, United States
| | - Benjamin J. Keenan
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, Massachusetts 02215, United States
| | - Jo Ann Buczek-Thomas
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, Massachusetts 02215, United States
| | - Amanda C. S. N. Pessoa
- Laboratoire de Microfluidique, MEMS et Nanostructures, ESPCI Paris, PSL Research University, Institut Pierre Gilles de Gennes (IPGG), CNRS (CBI), 6 rue Jean Calvin, 75005 Paris, France
- School of Chemical Engineering, University of Campinas, UNICAMP, 500 Av Albert Einstein, 13083-852, Campinas, SP, Brazil
| | - Jiang Xu
- Laboratoire de Microfluidique, MEMS et Nanostructures, ESPCI Paris, PSL Research University, Institut Pierre Gilles de Gennes (IPGG), CNRS (CBI), 6 rue Jean Calvin, 75005 Paris, France
| | - Fabrice Monti
- Laboratoire de Microfluidique, MEMS et Nanostructures, ESPCI Paris, PSL Research University, Institut Pierre Gilles de Gennes (IPGG), CNRS (CBI), 6 rue Jean Calvin, 75005 Paris, France
| | - Patrick Tabeling
- Laboratoire de Microfluidique, MEMS et Nanostructures, ESPCI Paris, PSL Research University, Institut Pierre Gilles de Gennes (IPGG), CNRS (CBI), 6 rue Jean Calvin, 75005 Paris, France
| | - R. Glynn Holt
- Department of Mechanical Engineering, Boston University, 110 Cummington Mall, Boston, Massachusetts 02215, United States
| | - Jon O. Nagy
- NanoValent Pharmaceuticals Inc., 351-B Evergreen Drive, Bozeman, Montana 59715, United States
| | - Joyce Y. Wong
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, Massachusetts 02215, United States
- Division of Materials Science and Engineering, Boston University, 15 St. Mary’s Street, Boston, Massachusetts 02215, United States
- Corresponding Author:
| |
Collapse
|
20
|
Upadhyay A, Dalvi SV. Microbubble Formulations: Synthesis, Stability, Modeling and Biomedical Applications. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:301-343. [PMID: 30527395 DOI: 10.1016/j.ultrasmedbio.2018.09.022] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 09/25/2018] [Accepted: 09/26/2018] [Indexed: 05/12/2023]
Abstract
Microbubbles are increasingly being used in biomedical applications such as ultrasonic imaging and targeted drug delivery. Microbubbles typically range from 0.1 to 10 µm in size and consist of a protective shell made of lipids or proteins. The shell encapsulates a gaseous core containing gases such as oxygen, sulfur hexafluoride or perfluorocarbons. This review is a consolidated account of information available in the literature on research related to microbubbles. Efforts have been made to present an overview of microbubble synthesis techniques; microbubble stability; microbubbles as contrast agents in ultrasonic imaging and drug delivery vehicles; and side effects related to microbubble administration in humans. Developments related to the modeling of microbubble dissolution and stability are also discussed.
Collapse
Affiliation(s)
- Awaneesh Upadhyay
- Chemical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, India
| | - Sameer V Dalvi
- Chemical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, India.
| |
Collapse
|
21
|
Czernuszewicz TJ, Papadopoulou V, Rojas JD, Rajamahendiran RM, Perdomo J, Butler J, Harlacher M, O’Connell G, Zukić D, Aylward SR, Dayton PA, Gessner RC. A new preclinical ultrasound platform for widefield 3D imaging of rodents. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:075107. [PMID: 30068108 PMCID: PMC6045495 DOI: 10.1063/1.5026430] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Noninvasive in vivo imaging technologies enable researchers and clinicians to detect the presence of disease and longitudinally study its progression. By revealing anatomical, functional, or molecular changes, imaging tools can provide a near real-time assessment of important biological events. At the preclinical research level, imaging plays an important role by allowing disease mechanisms and potential therapies to be evaluated noninvasively. Because functional and molecular changes often precede gross anatomical changes, there has been a significant amount of research exploring the ability of different imaging modalities to track these aspects of various diseases. Herein, we present a novel robotic preclinical contrast-enhanced ultrasound system and demonstrate its use in evaluating tumors in a rodent model. By leveraging recent advances in ultrasound, this system favorably compares with other modalities, as it can perform anatomical, functional, and molecular imaging and is cost-effective, portable, and high throughput, without using ionizing radiation. Furthermore, this system circumvents many of the limitations of conventional preclinical ultrasound systems, including a limited field-of-view, low throughput, and large user variability.
Collapse
Affiliation(s)
| | - Virginie Papadopoulou
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina 27599, USA
| | - Juan D. Rojas
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina 27599, USA
| | | | - Jonathan Perdomo
- SonoVol, Inc., Research Triangle Park, North Carolina 27709, USA
| | - James Butler
- SonoVol, Inc., Research Triangle Park, North Carolina 27709, USA
| | - Max Harlacher
- SonoVol, Inc., Research Triangle Park, North Carolina 27709, USA
| | - Graeme O’Connell
- SonoVol, Inc., Research Triangle Park, North Carolina 27709, USA
| | - Dženan Zukić
- Kitware, Inc., Carrboro, North Carolina 27510, USA
| | | | - Paul A. Dayton
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina 27599, USA
| | - Ryan C. Gessner
- SonoVol, Inc., Research Triangle Park, North Carolina 27709, USA
- Author to whom correspondence should be addressed: . Current address: First Flight Venture Center, 2 Davis Dr., Research Triangle Park, NC 27709-3169. Telephone: 844-766-6865 x707
| |
Collapse
|
22
|
Segers T, Kruizinga P, Kok MP, Lajoinie G, de Jong N, Versluis M. Monodisperse Versus Polydisperse Ultrasound Contrast Agents: Non-Linear Response, Sensitivity, and Deep Tissue Imaging Potential. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1482-1492. [PMID: 29705522 DOI: 10.1016/j.ultrasmedbio.2018.03.019] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Revised: 03/21/2018] [Accepted: 03/21/2018] [Indexed: 05/21/2023]
Abstract
It has been proposed that monodisperse microbubble ultrasound contrast agents further increase the signal-to-noise ratio of contrast-enhanced ultrasound imaging. Here, the sensitivity of a polydisperse pre-clinical agent was compared experimentally with that of its size- and acoustically sorted derivatives by using narrowband pressure- and frequency-dependent scattering and attenuation measurements. The sorted monodisperse agents had up to a two-orders-of-magnitude increase in sensitivity, that is, in the average scattering cross section per bubble. Moreover, we found, for the first time, that the highly non-linear response of acoustically sorted microbubbles can be exploited to confine scattering and attenuation to the focal region of ultrasound fields used in clinical imaging. This property is a result of minimal pre-focal scattering and attenuation and can be used to minimize shadowing effects in deep tissue imaging. Moreover, it potentially allows for more localized therapy using microbubbles through the spatial control of resonant microbubble oscillations.
Collapse
Affiliation(s)
- Tim Segers
- Physics of Fluids Group and TechMed Centre, University of Twente, Enschede, The Netherlands.
| | - Pieter Kruizinga
- Biomedical Engineering, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands
| | - Maarten P Kok
- Physics of Fluids Group and TechMed Centre, University of Twente, Enschede, The Netherlands
| | - Guillaume Lajoinie
- Physics of Fluids Group and TechMed Centre, University of Twente, Enschede, The Netherlands
| | - Nico de Jong
- Biomedical Engineering, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands; Acoustical Wavefield imaging, Delft University of Technology, Delft, The Netherlands
| | - Michel Versluis
- Physics of Fluids Group and TechMed Centre, University of Twente, Enschede, The Netherlands; MESA+ Institute for Nanotechnology, University of Twente, Enschede, The Netherlands
| |
Collapse
|
23
|
Lin F, Tsuruta JK, Rojas JD, Dayton PA. Optimizing Sensitivity of Ultrasound Contrast-Enhanced Super-Resolution Imaging by Tailoring Size Distribution of Microbubble Contrast Agent. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:2488-2493. [PMID: 28668636 PMCID: PMC8330409 DOI: 10.1016/j.ultrasmedbio.2017.05.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 05/01/2017] [Accepted: 05/08/2017] [Indexed: 05/03/2023]
Abstract
Ultrasound contrast-enhanced super-resolution imaging has recently attracted attention because of its extraordinary ability to image vascular features much smaller than the ultrasound diffraction limit. This method requires sensitive detection of separable microbubble events despite a noisy tissue background to indicate the microvasculature, and any approach that could improve the sensitivity of the ultrasound system to individual microbubbles would be highly beneficial. In this study, we evaluated the effect of varying microbubble size on super-resolution imaging sensitivity. Microbubble preparations were size sorted into different mean diameters and then were imaged at equal concentrations. Commercially manufactured Definity and Optison were also imaged for comparison. Both in vitro experiments in phantom vessels and in vivo experiments imaging rat tumors revealed that the sensitivity of contrast-enhanced super-resolution imaging can be improved by using microbubbles with a larger diameter.
Collapse
Affiliation(s)
- Fanglue Lin
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA
| | - James K Tsuruta
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Juan D Rojas
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA.
| |
Collapse
|
24
|
Gnyawali V, Moon BU, Kieda J, Karshafian R, Kolios MC, Tsai SSH. Honey, I shrunk the bubbles: microfluidic vacuum shrinkage of lipid-stabilized microbubbles. SOFT MATTER 2017; 13:4011-4016. [PMID: 28379267 DOI: 10.1039/c7sm00128b] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
We present a microfluidic technique that shrinks lipid-stabilized microbubbles from O(100) to O(1) μm in diameter - the size that is desirable in applications as ultrasound contrast agents. We achieve microbubble shrinkage by utilizing vacuum channels that are adjacent to the microfluidic flow channels to extract air from the microbubbles. We tune a single parameter, the vacuum pressure, to accurately control the final microbubble size. Finally, we demonstrate that the resulting O(1) μm diameter microbubbles have similar stability to microfluidically generated microbubbles that are not exposed to vacuum shrinkage. We anticipate that, with additional scale-up, this simple approach to shrink microbubbles generated microfluidically will be desirable in ultrasound imaging and therapeutic applications.
Collapse
Affiliation(s)
- Vaskar Gnyawali
- Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, Canada.
| | | | | | | | | | | |
Collapse
|
25
|
Wang Z, Heath Martin K, Huang W, Dayton PA, Jiang X. Contrast Enhanced Superharmonic Imaging for Acoustic Angiography Using Reduced Form-Factor Lateral Mode Transmitters for Intravascular and Intracavity Applications. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:311-319. [PMID: 27775903 PMCID: PMC5300895 DOI: 10.1109/tuffc.2016.2619687] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Techniques to image the microvasculature may play an important role in imaging tumor-related angiogenesis and vasa vasorum associated with vulnerable atherosclerotic plaques. However, the microvasculature associated with these pathologies is difficult to detect using traditional B-mode ultrasound or even harmonic imaging due to small vessel size and poor differentiation from surrounding tissue. Acoustic angiography, a microvascular imaging technique that utilizes superharmonic imaging (detection of higher order harmonics of microbubble response), can yield a much higher contrast-to-tissue ratio than second harmonic imaging methods. In this paper, two dual-frequency transducers using lateral mode transmitters were developed for superharmonic detection and acoustic angiography imaging in intracavity applications. A single element dual-frequency intravascular ultrasound transducer was developed for concept validation, which achieved larger signal amplitude, better contrast-to-noise ratio (CNR), and pulselength compared to the previous work. A dual-frequency [Pb(Mg1/3Nb2/3)O3]-x[PbTiO3] array transducer was then developed for superharmonic imaging with dynamic focusing. The axial and lateral sizes of the microbubbles in a 200- [Formula: see text] tube were measured to be 269 and [Formula: see text], respectively. The maximum CNR was calculated to be 22 dB. These results show that superharmonic imaging with a low frequency lateral mode transmitter is a feasible alternative to thickness mode transmitters when the final transducer size requirements dictate design choices.
Collapse
|
26
|
Freeling JL, Rezvani K. Assessment of murine colorectal cancer by micro-ultrasound using three dimensional reconstruction and non-linear contrast imaging. MOLECULAR THERAPY-METHODS & CLINICAL DEVELOPMENT 2016; 5:16070. [PMID: 28053998 PMCID: PMC5147881 DOI: 10.1038/mtm.2016.70] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2016] [Revised: 09/20/2016] [Accepted: 09/26/2016] [Indexed: 02/07/2023]
Abstract
The relatively low success rates of current colorectal cancer (CRC) therapies have led investigators to search for more specific treatments. Vertebrate models of colorectal cancer are essential tools for the verification of new therapeutic avenues such as gene therapy. The evaluation of colorectal cancer in mouse models has been limited due to the lack of an accurate quantitative and longitudinal noninvasive method. This work introduces a method of three-dimensional micro-ultrasound reconstruction and microbubble administration for the comprehensive and longitudinal evaluation of CRC progression. This approach enabled quantification of both tumor volume and relative vascularity using a well-established inducible murine model of colon carcinogenesis. This inducible model recapitulated the adenocarcinoma sequence that occurs in human CRC allowing systematic in situ evaluation of the ultrasound technique. The administration of intravenous microbubbles facilitated enhancement of colon vascular contrast and quantification of relative vascularity of the mid and distal colon of the mouse in three dimensions. In addition, two-dimensional imaging in the sagittal orientation of the colon using Non-Linear Contrast Mode enabled calculation of relative blood volume and perfusion as the microbubbles entered the colon microvasculature. Quantitative results provided by the outlined protocol represent a noninvasive tool that can more accurately define CRC development and progression. This ultrasound technique will allow the practical and economical longitudinal study of murine CRC in both basic and preclinical studies.
Collapse
Affiliation(s)
- Jessica L Freeling
- Division of Basic Biomedical Sciences, Sanford School of Medicine, The University of South Dakota , Vermillion, South Dakota, USA
| | - Khosrow Rezvani
- Division of Basic Biomedical Sciences, Sanford School of Medicine, The University of South Dakota , Vermillion, South Dakota, USA
| |
Collapse
|
27
|
Shelton SE, Lindsey BD, Tsuruta JK, Foster FS, Dayton PA. Molecular Acoustic Angiography: A New Technique for High-resolution Superharmonic Ultrasound Molecular Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:769-81. [PMID: 26678155 PMCID: PMC5653972 DOI: 10.1016/j.ultrasmedbio.2015.10.015] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Revised: 10/14/2015] [Accepted: 10/18/2015] [Indexed: 05/09/2023]
Abstract
Ultrasound molecular imaging utilizes targeted microbubbles to bind to vascular targets such as integrins, selectins and other extracellular binding domains. After binding, these microbubbles are typically imaged using low pressures and multi-pulse imaging sequences. In this article, we present an alternative approach for molecular imaging using ultrasound that relies on superharmonic signals produced by microbubble contrast agents. Bound bubbles were insonified near resonance using a low frequency (4 MHz) element and superharmonic echoes were received at high frequencies (25-30 MHz). Although this approach was observed to produce declining image intensity during repeated imaging in both in vitro and in vivo experiments because of bubble destruction, the feasibility of superharmonic molecular imaging was demonstrated for transmit pressures, which are sufficiently high to induce shell disruption in bound microbubbles. This approach was validated using microbubbles targeted to the αvβ3 integrin in a rat fibrosarcoma model (n = 5) and combined with superharmonic images of free microbubbles to produce high-contrast, high-resolution 3-D volumes of both microvascular anatomy and molecular targeting. Image intensity over repeated scans and the effect of microbubble diameter were also assessed in vivo, indicating that larger microbubbles yield increased persistence in image intensity. Using ultrasound-based acoustic angiography images rather than conventional B-mode ultrasound to provide the underlying anatomic information facilitates anatomic localization of molecular markers. Quantitative analysis of relationships between microvasculature and targeting information indicated that most targeting occurred within 50 μm of a resolvable vessel (>100 μm diameter). The combined information provided by these scans may present new opportunities for analyzing relationships between microvascular anatomy and vascular targets, subject only to limitations of the current mechanically scanned system and microbubble persistence to repeated imaging at moderate mechanical indices.
Collapse
Affiliation(s)
- Sarah E Shelton
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Brooks D Lindsey
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA
| | - James K Tsuruta
- Department of Pediatrics, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - F Stuart Foster
- Department of Medical Biophysics, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA; Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
| |
Collapse
|
28
|
Josefsson L, Larsson MK, Bjällmark A, Emmer Å. Analysis of polyvinyl alcohol microbubbles in human blood plasma using capillary electrophoresis. J Sep Sci 2016; 39:1551-8. [PMID: 26914238 DOI: 10.1002/jssc.201501342] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Revised: 02/11/2016] [Accepted: 02/11/2016] [Indexed: 11/07/2022]
Abstract
Recently, a new type of ultrasound contrast agent that consists of air-filled microbubbles stabilized with a shell of polyvinyl alcohol was developed. When superparamagnetic nanoparticles of iron oxide are incorporated in the polymer shell, a multimodal contrast agent can be obtained. The biodistribution and elimination pathways of the polyvinyl alcohol microbubbles are essential to investigate, which is limited with today's techniques. The aim of the present study was, therefore, to develop a method for qualitative and quantitative analysis of microbubbles in biological samples using capillary electrophoresis with ultraviolet detection. The analysis parameters were optimized to a wavelength at 260 nm and pH of the background electrolyte ranging between 11.9 and 12. Studies with high-intensity ultrasonication degraded microbubbles in water showed that degraded products and intact microbubbles could be distinguished, thus it was possible to quantify the intact microbubbles solely. Analysis of human blood plasma spiked with either plain microbubbles or microbubbles with nanoparticles demonstrated that it is possible to separate them from biological components like proteins in these kinds of samples.
Collapse
Affiliation(s)
- Leila Josefsson
- Analytical Chemistry, Div. of Applied Physical Chemistry, Dept. of Chemistry, School of Chemical Science and Engineering, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Malin K Larsson
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Anna Bjällmark
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden.,Department of Molecular Medicine and Surgery, Karolinska Institute, Stockholm, Sweden
| | - Åsa Emmer
- Analytical Chemistry, Div. of Applied Physical Chemistry, Dept. of Chemistry, School of Chemical Science and Engineering, KTH Royal Institute of Technology, Stockholm, Sweden
| |
Collapse
|
29
|
Li Y, Ma J, Martin KH, Yu M, Ma T, Dayton PA, Jiang X, Shung KK, Zhou Q. An Integrated System for Superharmonic Contrast-Enhanced Ultrasound Imaging: Design and Intravascular Phantom Imaging Study. IEEE Trans Biomed Eng 2015; 63:1933-1943. [PMID: 26672030 DOI: 10.1109/tbme.2015.2506639] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
OBJECTIVE Superharmonic contrast-enhanced ultrasound imaging, also called acoustic angiography, has previously been used for the imaging of microvasculature. This approach excites microbubble contrast agents near their resonance frequency and receives echoes at nonoverlapping superharmonic bandwidths. No integrated system currently exists could fully support this application. To fulfill this need, an integrated dual-channel transmit/receive system for superharmonic imaging was designed, built, and characterized experimentally. METHOD The system was uniquely designed for superharmonic imaging and high-resolution B-mode imaging. A complete ultrasound system including a pulse generator, a data acquisition unit, and a signal processing unit were integrated into a single package. The system was controlled by a field-programmable gate array, on which multiple user-defined modes were implemented. A 6-, 35-MHz dual-frequency dual-element intravascular ultrasound transducer was designed and used for imaging. RESULT The system successfully obtained high-resolution B-mode images of coronary artery ex vivo with 45-dB dynamic range. The system was capable of acquiring in vitro superharmonic images of a vasa vasorum mimicking phantom with 30-dB contrast. It could detect a contrast agent filled tissue mimicking tube of 200 μm diameter. CONCLUSION For the first time, high-resolution B-mode images and superharmonic images were obtained in an intravascular phantom, made possible by the dedicated integrated system proposed. The system greatly reduced the cost and complexity of the superharmonic imaging intended for preclinical study. Significant: The system showed promise for high-contrast intravascular microvascular imaging, which may have significant importance in assessment of the vasa vasorum associated with atherosclerotic plaques.
Collapse
|
30
|
Kim J, Li S, Kasoji S, Dayton PA, Jiang X. Phantom evaluation of stacked-type dual-frequency 1-3 composite transducers: A feasibility study on intracavitary acoustic angiography. ULTRASONICS 2015; 63:7-15. [PMID: 26112426 DOI: 10.1016/j.ultras.2015.06.009] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2015] [Revised: 06/08/2015] [Accepted: 06/10/2015] [Indexed: 06/04/2023]
Abstract
In this paper, we present phantom evaluation results of a stacked-type dual-frequency 1-3 piezoelectric composite transducer as a feasibility study for intracavitary acoustic angiography. Our previous design (6.5/30 MHz PMN-PT single crystal transducer) for intravascular contrast ultrasound imaging exhibited a contrast-to-tissue ratio (CTR) of 12 dB with a penetration depth of 2.5 mm. For improved penetration depth (>3 mm) and comparable contrast-to-tissue ratio (>12 dB), we evaluated a lower frequency 2/14 MHz PZT 1-3 composite transducer. Superharmonic imaging performance of this transducer and a detailed characterization of key parameters for acoustic angiography are presented. The 2/14 MHz arrangement demonstrated a -6 dB fractional bandwidth of 56.5% for the transmitter and 41.8% for the receiver, and produced sufficient peak-negative pressures (>1.5 MPa) at 2 MHz to induce a strong nonlinear harmonic response from microbubble contrast agents. In an in-vitro contrast ultrasound study using a tissue mimicking phantom and 200 μm cellulose microvessels, higher harmonic microbubble responses, from the 5th through the 7th harmonics, were detected with a signal-to-noise ratio of 16 dB. The microvessels were resolved in a two-dimensional image with a -6dB axial resolution of 615 μm (5.5 times the wavelength of 14 MHz waves) and a contrast-to-tissue ratio of 16 dB. This feasibility study, including detailed explanation of phantom evaluation and characterization procedures for key parameters, will be useful for the development of future dual-frequency array transducers for intracavitary acoustic angiography.
Collapse
Affiliation(s)
- Jinwook Kim
- Department of Mechanical & Aerospace Engineering, The North Carolina State University, Raleigh, NC 27695, USA
| | - Sibo Li
- Department of Mechanical & Aerospace Engineering, The North Carolina State University, Raleigh, NC 27695, USA
| | - Sandeep Kasoji
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, NC 27599, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, NC 27599, USA
| | - Xiaoning Jiang
- Department of Mechanical & Aerospace Engineering, The North Carolina State University, Raleigh, NC 27695, USA.
| |
Collapse
|
31
|
Dayton PA, Gessner RC, Phillips L, Shelton SE, Heath Martin K, Lee M, Foster FS. The implementation of acoustic angiography for microvascular and angiogenesis imaging. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:4283-5. [PMID: 25570939 DOI: 10.1109/embc.2014.6944571] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Recently, it has been demonstrated that through the use of contrast agents and multi-frequency transducer technology, high resolution and high signal to noise ultrasound images can be obtained which illustrate microvascular structure in unprecedented detail for an ultrasound modality. The enabling technology is ultrasound transducers which are fabricated with elements which can excite microbubble contrast agents near resonance and detect their broadband harmonics at a much higher bandwidth (several times the fundamental frequency). The resulting images contain very little background from tissue scattering and thus provide high contrast, and can have a resolution on the order of 130 microns with an appropriate high frequency receiving element. Because microbubbles are strictly an intravascular agent, this approach enables visualization of microvascular morphology with unique clarity, providing insight into angiogenesis associated with tumor development.
Collapse
|
32
|
Lindsey BD, Shelton SE, Dayton PA. Optimization of Contrast-to-Tissue Ratio Through Pulse Windowing in Dual-Frequency "Acoustic Angiography" Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1884-95. [PMID: 25819467 PMCID: PMC4804889 DOI: 10.1016/j.ultrasmedbio.2015.02.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2014] [Revised: 02/16/2015] [Accepted: 02/21/2015] [Indexed: 05/09/2023]
Abstract
Early-stage tumors in many cancers are characterized by vascular remodeling, indicative of transformations in cell function. We have previously presented a high-resolution ultrasound imaging approach to detecting these changes that is based on microbubble contrast agents. In this technique, images are formed from only the higher harmonics of microbubble contrast agents, producing images of vasculature alone with 100- to 200-μm resolution. In this study, shaped transmit pulses were used to image the higher broadband harmonic echoes of microbubble contrast agents, and the effects of varying pulse window and phasing on microbubble and tissue harmonic echoes were evaluated using a dual-frequency transducer in vitro and in vivo. An increase in the contrast-to-tissue ratio of 6.8 ± 2.3 dB was observed in vitro using an inverted pulse with a cosine window relative to a non-inverted pulse with a rectangular window. The increase in mean image intensity resulting from contrast enhancement in vivo in five rodents was 13.9 ± 3.0 dB greater for an inverted cosine-windowed pulse and 17.8 ± 3.6 dB greater for a non-inverted Gaussian-windowed pulse relative to a non-inverted pulse with a rectangular window. Implications for pre-clinical and diagnostic imaging are discussed.
Collapse
Affiliation(s)
- Brooks D Lindsey
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Sarah E Shelton
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
| |
Collapse
|
33
|
Lindsey BD, Rojas JD, Dayton PA. On the relationship between microbubble fragmentation, deflation and broadband superharmonic signal production. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1711-25. [PMID: 25766572 PMCID: PMC4778426 DOI: 10.1016/j.ultrasmedbio.2014.12.668] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2014] [Revised: 12/18/2014] [Accepted: 12/20/2014] [Indexed: 05/19/2023]
Abstract
Acoustic angiography imaging of microbubble contrast agents uses the superharmonic energy produced from excited microbubbles and enables high-contrast, high-resolution imaging. However, the exact mechanism by which broadband harmonic energy is produced is not fully understood. To elucidate the role of microbubble shell fragmentation in superharmonic signal production, simultaneous optical and acoustic measurements were performed on individual microbubbles at transmit frequencies from 1.75 to 3.75 MHz and pressures near the shell fragmentation threshold for microbubbles of varying diameter. High-amplitude, broadband superharmonic signals were produced with shell fragmentation, whereas weaker signals (approximately 25% of peak amplitude) were observed in the presence of shrinking bubbles. Furthermore, when populations of stationary microbubbles were imaged with a dual-frequency ultrasound imaging system, a sharper decline in image intensity with respect to frame number was observed for 1-μm bubbles than for 4-μm bubbles. Finally, in a study of two rodents, increasing frame rate from 4 to 7 Hz resulted in decreases in mean steady-state image intensity of 27% at 1000 kPa and 29% at 1300 kPa. Although the existence of superharmonic signals when bubbles shrink has the potential to prolong the imaging efficacy of microbubbles, parameters such as frame rate and peak pressure must be balanced with expected re-perfusion rate to maintain adequate contrast during in vivo imaging.
Collapse
Affiliation(s)
- Brooks D Lindsey
- Joint Department of Biomedical Engineering, University of North Carolina-Chapel Hill and North Carolina State University, Raleigh, North Carolina, USA
| | - Juan D Rojas
- Joint Department of Biomedical Engineering, University of North Carolina-Chapel Hill and North Carolina State University, Raleigh, North Carolina, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina-Chapel Hill and North Carolina State University, Raleigh, North Carolina, USA.
| |
Collapse
|
34
|
Moyer LC, Timbie KF, Sheeran PS, Price RJ, Miller GW, Dayton PA. High-intensity focused ultrasound ablation enhancement in vivo via phase-shift nanodroplets compared to microbubbles. J Ther Ultrasound 2015; 3:7. [PMID: 26045964 PMCID: PMC4455327 DOI: 10.1186/s40349-015-0029-4] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Accepted: 05/15/2015] [Indexed: 12/28/2022] Open
Abstract
Background During high-intensity focused ultrasound (HIFU) surgical procedures, there is a need to rapidly ablate pathological tissue while minimizing damage to healthy tissue. Current techniques are limited by relatively long procedure times and risks of off-target heating of healthy tissue. One possible solution is the use of microbubbles, which can improve the efficiency of thermal energy delivery during HIFU procedures. However, microbubbles also suffer from limitations such as low spatial selectivity and short circulation time in vivo. In this study, the use of a dual-perfluorocarbon nanodroplet that can enhance thermal ablation, yet retains high spatial selectivity and circulation half-life, was evaluated in vivo and compared to traditional microbubble agents during HIFU ablations of rat liver. Methods High-intensity focused ultrasound (1.1 MHz, 4.1 MPa, 15-s continuous wave) was applied to rat liver in vivo, and heating was monitored during sonication by magnetic resonance thermometry. Thermometry data were analyzed to quantify temperature rise and ablated area, both at the target and prefocally, for HIFU applied 5, 15, or 95 min after intravenous injection of either nanodroplet or microbubble agents. Sham control experiments (no injected agents) were also performed. Results At all three time points, nanodroplets significantly enhanced thermal delivery to the target, achieving temperatures 130 % higher and ablated areas 30 times larger than no-agent control sonications. Nanodroplets did not significantly enhance off-target surface heating. Microbubbles also resulted in significantly greater thermal delivery, but heating was concentrated at the proximal surface of the animal, causing skin burns. Furthermore, microbubbles resulted in lower thermal delivery to the desired target than even the control case, with the notable exception of the 95-min time point. Conclusions Results indicate that the nanodroplet formulation studied here can substantially increase thermal delivery at the acoustic focus while avoiding prefocal heating. In contrast, microbubbles resulted in greater prefocal heating and less heating at the target. Furthermore, nanodroplets are sufficiently stable to enhance HIFU ablation in vivo for at least 1.5 h after injection. The use of a dual-perfluorocarbon nanodroplet formulation as described herein could substantially reduce HIFU procedure times without increasing the risk of skin burns.
Collapse
Affiliation(s)
- Linsey C Moyer
- Joint Department of Biomedical Engineering, University of North Carolina-Chapel Hill and NC State University Campus, Box 7575, Chapel Hill, NC 27599 USA
| | - Kelsie F Timbie
- Department of Biomedical Engineering, University of Virginia, Box 800759, Charlottesville, Virginia 22908 USA
| | - Paul S Sheeran
- Joint Department of Biomedical Engineering, University of North Carolina-Chapel Hill and NC State University Campus, Box 7575, Chapel Hill, NC 27599 USA
| | - Richard J Price
- Department of Biomedical Engineering, University of Virginia, Box 800759, Charlottesville, Virginia 22908 USA ; Department of Radiology and Medical Imaging, University of Virginia, Box 801339, Charlottesville, Virginia 22908 USA
| | - G Wilson Miller
- Department of Biomedical Engineering, University of Virginia, Box 800759, Charlottesville, Virginia 22908 USA ; Department of Radiology and Medical Imaging, University of Virginia, Box 801339, Charlottesville, Virginia 22908 USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, University of North Carolina-Chapel Hill and NC State University Campus, Box 7575, Chapel Hill, NC 27599 USA
| |
Collapse
|
35
|
Ultrasound molecular imaging of tumor angiogenesis with a neuropilin-1-targeted microbubble. Biomaterials 2015; 56:104-13. [PMID: 25934284 DOI: 10.1016/j.biomaterials.2015.03.043] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Revised: 03/15/2015] [Accepted: 03/20/2015] [Indexed: 02/06/2023]
Abstract
Ultrasound molecular imaging has great potential to impact early disease diagnosis, evaluation of disease progression and the development of target-specific therapy. In this paper, two neuropilin-1 (NRP) targeted peptides, CRPPR and ATWLPPR, were conjugated onto the surface of lipid microbubbles (MBs) to evaluate molecular imaging of tumor angiogenesis in a breast cancer model. Development of a molecular imaging agent using CRPPR has particular importance due to the previously demonstrated internalizing capability of this and similar ligands. In vitro, CRPPR MBs bound to an NRP-expressing cell line 2.6 and 15.6 times more than ATWLPPR MBs and non-targeted (NT) MBs, respectively, and the binding was inhibited by pretreating the cells with an NRP antibody. In vivo, the backscattered intensity within the tumor, relative to nearby vasculature, increased over time during the ∼6 min circulation of the CRPPR-targeted contrast agents providing high contrast images of angiogenic tumors. Approximately 67% of the initial signal from CRPPR MBs remained bound after the majority of circulating MBs had cleared (8 min), 8 and 4.5 times greater than ATWLPPR and NT MBs, respectively. Finally, at 7-21 days after the first injection, we found that CRPPR MBs cleared faster from circulation and tumor accumulation was reduced likely due to a complement-mediated recognition of the targeted microbubble and a decrease in angiogenic vasculature, respectively. In summary, we find that CRPPR MBs specifically bind to NRP-expressing cells and provide an effective new agent for molecular imaging of angiogenesis.
Collapse
|
36
|
Ma J, Martin KH, Li Y, Dayton PA, Shung KK, Zhou Q, Jiang X. Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography. Phys Med Biol 2015; 60:3441-57. [PMID: 25856384 DOI: 10.1088/0031-9155/60/9/3441] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Imaging of coronary vasa vasorum may lead to assessment of the vulnerable plaque development in diagnosis of atherosclerosis diseases. Dual frequency transducers capable of detection of microbubble super-harmonics have shown promise as a new contrast-enhanced intravascular ultrasound (CE-IVUS) platform with the capability of vasa vasorum imaging. Contrast-to-tissue ratio (CTR) in CE-IVUS imaging can be closely associated with low frequency transmitter performance. In this paper, transducer designs encompassing different transducer layouts, transmitting frequencies, and transducer materials are compared for optimization of imaging performance. In the layout selection, the stacked configuration showed superior super-harmonic imaging compared with the interleaved configuration. In the transmitter frequency selection, a decrease in frequency from 6.5 MHz to 5 MHz resulted in an increase of CTR from 15 dB to 22 dB when receiving frequency was kept constant at 30 MHz. In the material selection, the dual frequency transducer with the lead magnesium niobate-lead titanate (PMN-PT) 1-3 composite transmitter yielded higher axial resolution compared to single crystal transmitters (70 μm compared to 150 μm pulse length). These comparisons provide guidelines for the design of intravascular acoustic angiography transducers.
Collapse
Affiliation(s)
- Jianguo Ma
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA
| | | | | | | | | | | | | |
Collapse
|
37
|
van Rooij T, Daeichin V, Skachkov I, de Jong N, Kooiman K. Targeted ultrasound contrast agents for ultrasound molecular imaging and therapy. Int J Hyperthermia 2015; 31:90-106. [PMID: 25707815 DOI: 10.3109/02656736.2014.997809] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Ultrasound contrast agents (UCAs) are used routinely in the clinic to enhance contrast in ultrasonography. More recently, UCAs have been functionalised by conjugating ligands to their surface to target specific biomarkers of a disease or a disease process. These targeted UCAs (tUCAs) are used for a wide range of pre-clinical applications including diagnosis, monitoring of drug treatment, and therapy. In this review, recent achievements with tUCAs in the field of molecular imaging, evaluation of therapy, drug delivery, and therapeutic applications are discussed. We present the different coating materials and aspects that have to be considered when manufacturing tUCAs. Next to tUCA design and the choice of ligands for specific biomarkers, additional techniques are discussed that are applied to improve binding of the tUCAs to their target and to quantify the strength of this bond. As imaging techniques rely on the specific behaviour of tUCAs in an ultrasound field, it is crucial to understand the characteristics of both free and adhered tUCAs. To image and quantify the adhered tUCAs, the state-of-the-art techniques used for ultrasound molecular imaging and quantification are presented. This review concludes with the potential of tUCAs for drug delivery and therapeutic applications.
Collapse
Affiliation(s)
- Tom van Rooij
- Department of Biomedical Engineering, Thoraxcenter , Erasmus MC, Rotterdam , the Netherlands
| | | | | | | | | |
Collapse
|
38
|
Czarnecka AM, Kornakiewicz A, Kukwa W, Szczylik C. Frontiers in clinical and molecular diagnostics and staging of metastatic clear cell renal cell carcinoma. Future Oncol 2015; 10:1095-111. [PMID: 24941992 DOI: 10.2217/fon.13.258] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
The last few years have brought advances in the understanding of the molecular biology of metastatic clear cell renal cell carcinoma (RCC). Both preclinical research and clinical trials brought together results from the latest advancements in RCC diagnostic and staging. Understanding of the complex molecular alterations involved in the development and progression of RCC enables development of immunohistochemical and genetic diagnostic tools and is also opening the doors for experimental targeted therapies. At the same time, improvements of medical and molecular imaging improves the sensitivity and specificity of metastatic disease diagnosis. Moreover, independent validation of molecular profiles across high-throughput platforms, methods, laboratories and cancer populations has recently been successfully performed in RCC. Generation of informative, clinical diagnostic tools is likely to contribute to development of novel personalized diagnostic and treatment protocols and ensure prolonged survival of RCC patient in the near future.
Collapse
Affiliation(s)
- Anna M Czarnecka
- Department of Oncology with Laboratory of Molecular Oncology, Military Institute of Medicine, Szaserow 128, 04-141 Warsaw, Poland
| | | | | | | |
Collapse
|
39
|
Dove JD, Mountford PA, Murray TW, Borden MA. Engineering optically triggered droplets for photoacoustic imaging and therapy. BIOMEDICAL OPTICS EXPRESS 2014; 5:4417-27. [PMID: 25574448 PMCID: PMC4285615 DOI: 10.1364/boe.5.004417] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Revised: 11/20/2014] [Accepted: 11/21/2014] [Indexed: 05/20/2023]
Abstract
Liquid perfluorocarbon (PFC) droplets incorporating optical absorbers can be vaporized through photothermal heating using a pulsed laser source. Here, we report on the effect of droplet core material on the optical fluence required to produce droplet vaporization. We fabricate gold nanoparticle templated microbubbles filled with various PFC gases (C3F8, C4F10, and C5F12) and apply pressure to condense them into droplets. The core material is found to have a strong effect on the threshold optical fluence, with lower boiling point droplets allowing for vaporization at lower laser fluence. The impact of droplet size on vaporization threshold is discussed, as well as a proposed mechanism for the relatively broad distribution of vaporization thresholds observed within a droplet population with the same core material. We propose that the control of optical vaporization threshold enabled by engineering the droplet core may find application in contrast enhanced photoacoustic imaging and therapy.
Collapse
Affiliation(s)
- Jacob D. Dove
- Department of Mechanical Engineering, University of Colorado Boulder, 427 UCB, Boulder, Colorado 80309,
USA
| | - Paul A. Mountford
- Department of Mechanical Engineering, University of Colorado Boulder, 427 UCB, Boulder, Colorado 80309,
USA
| | - Todd W. Murray
- Department of Mechanical Engineering, University of Colorado Boulder, 427 UCB, Boulder, Colorado 80309,
USA
| | - Mark A. Borden
- Department of Mechanical Engineering, University of Colorado Boulder, 427 UCB, Boulder, Colorado 80309,
USA
| |
Collapse
|
40
|
Segers T, de Jong N, Lohse D, Versluis M. Microbubbles for Medical Applications. MICROFLUIDICS FOR MEDICAL APPLICATIONS 2014. [DOI: 10.1039/9781849737593-00081] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Ultrasound contrast agent (UCA) suspensions contain encapsulated microbubbles with radii ranging from 1 to 10 micrometers. The bubbles oscillate to the driving ultrasound pulse generating harmonics of the driving ultrasound frequency. This feature allows for the discrimination of non-linear bubble echoes from linear tissue echoes facilitating the visualization and quantification of blood perfusion in organs. Targeting the microbubbles to specific receptors in the body has led to molecular imaging application with ultrasound and targeted drug delivery with drug-loaded microbubbles. Traditional UCA production methods offer high yield but poor control over the microbubble size and uniformity. Medical ultrasound transducers typically operate at a single frequency, therefore only a small selection of bubbles resonates to the driving ultrasound pulse. Here we discuss recent lab-on-a-chip based production and sorting methods that have been shown to produce highly monodisperse bubbles, thereby improving the sensitivity of contrast-enhanced ultrasound imaging and molecular imaging with microbubbles. Moreover, monodisperse UCA show great potential for targeted drug delivery by the well-controlled bubble response.
Collapse
Affiliation(s)
- Tim Segers
- Physics of Fluids Group, MIRA Institute for Biomedical Technology and Technical Medicine, MESA+ Institute for Nanotechnology, University of Twente PO Box 217 7500 AE Enschede The Netherlands
| | - Nico de Jong
- Physics of Fluids Group, MIRA Institute for Biomedical Technology and Technical Medicine, MESA+ Institute for Nanotechnology, University of Twente PO Box 217 7500 AE Enschede The Netherlands
| | - Detlef Lohse
- Physics of Fluids Group, MIRA Institute for Biomedical Technology and Technical Medicine, MESA+ Institute for Nanotechnology, University of Twente PO Box 217 7500 AE Enschede The Netherlands
| | - Michel Versluis
- Physics of Fluids Group, MIRA Institute for Biomedical Technology and Technical Medicine, MESA+ Institute for Nanotechnology, University of Twente PO Box 217 7500 AE Enschede The Netherlands
| |
Collapse
|
41
|
Dual-frequency piezoelectric transducers for contrast enhanced ultrasound imaging. SENSORS 2014; 14:20825-42. [PMID: 25375755 PMCID: PMC4279513 DOI: 10.3390/s141120825] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2014] [Revised: 10/03/2014] [Accepted: 10/16/2014] [Indexed: 01/10/2023]
Abstract
For many years, ultrasound has provided clinicians with an affordable and effective imaging tool for applications ranging from cardiology to obstetrics. Development of microbubble contrast agents over the past several decades has enabled ultrasound to distinguish between blood flow and surrounding tissue. Current clinical practices using microbubble contrast agents rely heavily on user training to evaluate degree of localized perfusion. Advances in separating the signals produced from contrast agents versus surrounding tissue backscatter provide unique opportunities for specialized sensors designed to image microbubbles with higher signal to noise and resolution than previously possible. In this review article, we describe the background principles and recent developments of ultrasound transducer technology for receiving signals produced by contrast agents while rejecting signals arising from soft tissue. This approach relies on transmitting at a low-frequency and receiving microbubble harmonic signals at frequencies many times higher than the transmitted frequency. Design and fabrication of dual-frequency transducers and the extension of recent developments in transducer technology for dual-frequency harmonic imaging are discussed.
Collapse
|
42
|
Angilè F, Vargo KB, Sehgal CM, Hammer DA, Lee D. Recombinant protein-stabilized monodisperse microbubbles with tunable size using a valve-based microfluidic device. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2014; 30:12610-8. [PMID: 25265041 PMCID: PMC4211726 DOI: 10.1021/la502610c] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2014] [Revised: 08/21/2014] [Indexed: 05/05/2023]
Abstract
Microbubbles are used as contrast enhancing agents in ultrasound sonography and more recently have shown great potential as theranostic agents that enable both diagnostics and therapy. Conventional production methods lead to highly polydisperse microbubbles, which compromise the effectiveness of ultrasound imaging and therapy. Stabilizing microbubbles with surfactant molecules that can impart functionality and properties that are desirable for specific applications would enhance the utility of microbubbles. Here we generate monodisperse microbubbles with a large potential for functionalization by combining a microfluidic method and recombinant protein technology. Our microfluidic device uses an air-actuated membrane valve that enables production of monodisperse microbubbles with narrow size distribution. The size of microbubbles can be precisely tuned by dynamically changing the dimension of the channel using the valve. The microbubbles are stabilized by an amphiphilic protein, oleosin, which provides versatility in controlling the functionalization of microbubbles through recombinant biotechnology. We show that it is critical to control the composition of the stabilizing agents to enable formation of highly stable and monodisperse microbubbles that are echogenic under ultrasound insonation. Our protein-shelled microbubbles based on the combination of microfluidic generation and recombinant protein technology provide a promising platform for ultrasound-related applications.
Collapse
Affiliation(s)
- Francesco
E. Angilè
- Department
of Chemical and Biomolecular Engineering and Department of Bioengineering, School
of Engineering and Applied Science, University
of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Kevin B. Vargo
- Department
of Chemical and Biomolecular Engineering and Department of Bioengineering, School
of Engineering and Applied Science, University
of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Chandra M. Sehgal
- Department
of Radiology, University of Pennsylvania
Medical Center, Philadelphia, Pennsylvania 19104, United States
| | - Daniel A. Hammer
- Department
of Chemical and Biomolecular Engineering and Department of Bioengineering, School
of Engineering and Applied Science, University
of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Daeyeon Lee
- Department
of Chemical and Biomolecular Engineering and Department of Bioengineering, School
of Engineering and Applied Science, University
of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|
43
|
Vascular channels formed by subpopulations of PECAM1+ melanoma cells. Nat Commun 2014; 5:5200. [PMID: 25335460 PMCID: PMC4261234 DOI: 10.1038/ncomms6200] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2013] [Accepted: 09/09/2014] [Indexed: 12/18/2022] Open
Abstract
Targeting the vasculature remains a promising approach for treating solid tumors; however, the mechanisms of tumor neovascularization are diverse and complex. Here we uncover a new subpopulation of melanoma cells that express the vascular cell adhesion molecule PECAM1, but not VEGFR-2, and participate in a PECAM1-dependent form of vasculogenic mimicry (VM). Clonally-derived PECAM1+ tumor cells coalesce to form PECAM1-dependent networks in vitro and they generate well-perfused, VEGF-independent channels in mice. The neural crest specifier AP-2α is diminished in PECAM1+ melanoma cells and is a transcriptional repressor of PECAM1. Reintroduction of AP-2α into PECAM1+ tumor cells represses PECAM1 and abolishes tube-forming ability whereas AP-2α knockdown in PECAM1− tumor cells up-regulates PECAM1 expression and promotes tube formation. Thus, VM-competent subpopulations, rather than all cells within a tumor, may instigate VM, supplant host-derived endothelium, and form PECAM1-dependent conduits that are not diminished by neutralizing VEGF.
Collapse
|
44
|
Lindsey BD, Rojas JD, Martin KH, Shelton SE, Dayton PA. Acoustic characterization of contrast-to-tissue ratio and axial resolution for dual-frequency contrast-specific acoustic angiography imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:1668-87. [PMID: 25265176 PMCID: PMC8375273 DOI: 10.1109/tuffc.2014.006466] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Recently, dual-frequency transducers have enabled high-spatial-resolution and high-contrast imaging of vasculature with minimal tissue artifacts by transmitting at a low frequency and receiving broadband superharmonic echoes scattered by microbubble contrast agents. In this work, we examine the imaging parameters for optimizing contrast-to-tissue ratio (CTR) for dual-frequency imaging and the relationship with spatial resolution. Confocal piston transducers are used in a water bath setup to measure the SNR, CTR, and axial resolution for ultrasound imaging of nonlinear scattering of microbubble contrast agents when transmitting at a lower frequency (1.5 to 8 MHz) and receiving at a higher frequency (7.5 to 25 MHz). Parameters varied include the frequency and peak negative pressure of transmitted waves, center frequency of the receiving transducer, microbubble concentration, and microbubble size. CTR is maximized at the lowest transmission frequencies but would be acceptable for imaging in the 1.5 to 3.5 MHz range. At these frequencies, CTR is optimized when a receiving transducer with a center frequency of 10 MHz is used, with the maximum CTR of 25.5 dB occurring when transmitting at 1.5 MHz with a peak negative pressure of 1600 kPa and receiving with a center frequency of 10 MHz. Axial resolution is influenced more heavily by the receiving center frequency, with a weak decrease in measured pulse lengths associated with increasing transmit frequency. A microbubble population containing predominately 4-μm-diameter bubbles yielded the greatest CTR, followed by 1- and then 2-μm bubbles. Varying concentration showed little effect over the tested parameters. CTR dependence on transmit frequency and peak pressure were confirmed through in vivo imaging in two rodents. These findings may lead to improved imaging of vascular remodeling in superficial or luminal cancers such as those of the breast, prostate, and colon.
Collapse
|
45
|
Goodwin AP, Nakatsuka MA, Mattrey RF. Stimulus-responsive ultrasound contrast agents for clinical imaging: motivations, demonstrations, and future directions. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2014; 7:111-23. [PMID: 25195785 DOI: 10.1002/wnan.1285] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2014] [Revised: 06/23/2014] [Accepted: 07/06/2014] [Indexed: 12/17/2022]
Abstract
Microbubble ultrasound contrast agents allow imaging of the vasculature with excellent resolution and signal-to-noise ratios. Contrast in microbubbles derives from their interaction with an ultrasound wave to generate signal at harmonic frequencies of the stimulating pulse; subtracting the elastic echo caused by the surrounding tissue can enhance the specificity of these harmonic signals significantly. The nonlinear acoustic emission is caused by pressure-driven microbubble size fluctuations, which in both theoretical descriptions and empirical measurements was found to depend on the mechanical properties of the shell that encapsulates the microbubble as well as stabilizes it against the surrounding aqueous environment. Thus biochemically induced switching between a rigid 'off' state and a flexible 'on' state provides a mechanism for sensing chemical markers for disease. In our research, we coupled DNA oligonucleotides to a stabilizing lipid monolayer to modulate stiffness of the shell and thereby induce stimulus-responsive behavior. In initial proof-of-principle studies, it was found that signal modulation came primarily from DNA crosslinks preventing the microbubble size oscillations rather than merely damping the signal. Next, these microbubbles were redesigned to include an aptamer sequence in the crosslinking strand, which not only allowed the sensing of the clotting enzyme thrombin but also provided a general strategy for sensing other soluble biomarkers in the bloodstream. Finally, the thrombin-sensitive microbubbles were validated in a rabbit model, presenting the first example of an ultrasound contrast agent that could differentiate between active and inactive clots for the diagnosis of deep venous thrombosis.
Collapse
Affiliation(s)
- Andrew P Goodwin
- Department of Chemical and Biological Engineering, University of Colorado Boulder, Boulder, CO, USA
| | | | | |
Collapse
|
46
|
Segers T, Versluis M. Acoustic bubble sorting for ultrasound contrast agent enrichment. LAB ON A CHIP 2014; 14:1705-14. [PMID: 24651248 DOI: 10.1039/c3lc51296g] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
An ultrasound contrast agent (UCA) suspension contains encapsulated microbubbles with a wide size distribution, with radii ranging from 1 to 10 μm. Medical transducers typically operate at a single frequency, therefore only a small selection of bubbles will resonate to the driving ultrasound pulse. Thus, the sensitivity can be improved by narrowing down the size distribution. Here, we present a simple lab-on-a-chip method to sort the population of microbubbles on-chip using a traveling ultrasound wave. First, we explore the physical parameter space of acoustic bubble sorting using well-defined bubble sizes formed in a flow-focusing device, then we demonstrate successful acoustic sorting of a commercial UCA. This novel sorting strategy may lead to an overall improvement of the sensitivity of contrast ultrasound by more than 10 dB.
Collapse
Affiliation(s)
- Tim Segers
- Physics of Fluids Group and MESA+ Institute of Nanotechnology, P.O. Box 217, 7500 AE Enschede, The Netherlands.
| | | |
Collapse
|
47
|
Shekhar H, Rychak JJ, Doyley MM. Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging. Med Phys 2014; 40:082903. [PMID: 23927358 DOI: 10.1118/1.4813017] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
PURPOSE Subharmonic imaging is of interest for high frequency (>10 MHz) nonlinear imaging, because it can specifically detect the response of ultrasound contrast agents (UCA). However, conventional UCA produce a weak subharmonic response at high frequencies, which limits the sensitivity of subharmonic imaging. We hypothesized that modifying the size distribution of the agent can enhance its high-frequency subharmonic response. The overall goal of this study was to investigate size-manipulated populations of the agent to determine the range of sizes that produce the strongest subharmonic response at high frequencies (in this case, 20 MHz). A secondary goal was to assess whether the number or the volume-weighted size distribution better represents the efficacy of the agent for high-frequency subharmonic imaging. METHODS The authors created six distinct agent size distributions from the native distribution of a commercially available UCA (Targestar-P®). The median (number-weighted) diameter of the native agent was 1.63 μm, while the median diameters of the size-manipulated populations ranged from 1.35 to 2.99 μm. The authors conducted acoustic measurements with native and size-manipulated agent populations to assess their subharmonic response to 20 MHz excitation (pulse duration 1.5 μs, pressure amplitudes 100-398 kPa). RESULTS The results showed a considerable difference between the subharmonic response of the agent populations that were investigated. The subharmonic response peaked for the agent population with a median diameter of 2.15 μm, which demonstrated a subharmonic signal that was 8 dB higher than the native agent. Comparing the subharmonic response of different UCA populations indicated that microbubbles with diameters between 1.3 and 3 μm are the dominant contributors to the subharmonic response at 20 MHz. Additionally, a better correlation was observed between the subharmonic response of the agent and the number-weighted size-distribution (R2=0.98) than with the volume-weighted size distribution (R2=0.53). CONCLUSIONS Modifying the size distribution of the agent appears to be a viable strategy to improve the sensitivity of high-frequency subharmonic imaging. In addition, when the size distribution of the UCA has not been suitably modified, the number-weighted size distribution is a useful parameter to accurately describe the efficacy of the agent for high-frequency subharmonic imaging.
Collapse
Affiliation(s)
- Himanshu Shekhar
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York 14627, USA
| | | | | |
Collapse
|
48
|
Sun C, Sboros V, Butler MB, Moran CM. In vitro acoustic characterization of three phospholipid ultrasound contrast agents from 12 to 43 MHz. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:541-50. [PMID: 24361219 PMCID: PMC3923973 DOI: 10.1016/j.ultrasmedbio.2013.10.010] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2013] [Revised: 10/09/2013] [Accepted: 10/13/2013] [Indexed: 05/13/2023]
Abstract
The acoustic properties of two clinical (Definity, Lantheus Medical Imaging, North Billerica, MA, USA; SonoVue, Bracco S.P.A., Milan, Italy) and one pre-clinical (MicroMarker, untargeted, Bracco, Geneva, Switzerland; VisualSonics, Toronto, ON, Canada) ultrasound contrast agent were characterized using a broadband substitution technique over the ultrasound frequency range 12-43 MHz at 20 ± 1°C. At the same number concentration, the acoustic attenuation and contrast-to-tissue ratio of the three native ultrasound contrast agents are comparable at frequencies below 30 MHz, though their size distributions and encapsulated gases and shells differ. At frequencies above 30 MHz, native MicroMarker has higher attenuation values and contrast-to-tissue ratios than native Definity and SonoVue. Decantation was found to be an effective method to alter the size distribution and concentration of native clinical microbubble populations, enabling further contrast enhancement for specific pre-clinical applications.
Collapse
Affiliation(s)
- Chao Sun
- Medical Physics, Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - Vassilis Sboros
- Medical Physics, Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom; Institute of Biochemistry, Biophysics and Bioengineering, Heriot-Watt University, Edinburgh, United Kingdom
| | - Mairead B Butler
- Medical Physics, Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom; Institute of Biochemistry, Biophysics and Bioengineering, Heriot-Watt University, Edinburgh, United Kingdom
| | - Carmel M Moran
- Medical Physics, Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom.
| |
Collapse
|
49
|
Ultrasound molecular imaging of secreted frizzled related protein-2 expression in murine angiosarcoma. PLoS One 2014; 9:e86642. [PMID: 24489757 PMCID: PMC3906081 DOI: 10.1371/journal.pone.0086642] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2013] [Accepted: 12/11/2013] [Indexed: 12/30/2022] Open
Abstract
Angiosarcoma is a biologically aggressive vascular malignancy with a high metastatic potential. In the era of targeted medicine, knowledge of specific molecular tumor characteristics has become more important. Molecular imaging using targeted ultrasound contrast agents can monitor tumor progression non-invasively. Secreted frizzled related protein 2 (SFRP2) is a tumor endothelial marker expressed in angiosarcoma. We hypothesize that SFRP2-directed imaging could be a novel approach to imaging the tumor vasculature. To develop an SFRP2 contrast agent, SFRP2 polyclonal antibody was biotinylated and incubated with streptavidin-coated microbubbles. SVR angiosarcoma cells were injected into nude mice, and when tumors were established the mice were injected intravenously with the SFRP2 -targeted contrast agent, or a control streptavidin-coated contrast agent. SFRP2 -targeted contrast agent detected tumor vasculature with significantly more signal intensity than control contrast agent: the normalized fold-change was 1.6 ± 0.27 (n = 13, p = 0.0032). The kidney was largely devoid of echogenicity with no significant difference between the control contrast agent and the SFRP2-targeted contrast agent demonstrating that the SFRP2-targeted contrast agent was specific to tumor vessels. Plotting average pixel intensity obtained from SFRP2-targeted contrast agent against tumor volume showed that the average pixel intensity increased as tumor volume increased. In conclusion, molecularly-targeted imaging of SFRP2 visualizes angiosarcoma vessels, but not normal vessels, and intensity increases with tumor size. Molecular imaging of SFRP2 expression may provide a rapid, non-invasive method to monitor tumor regression during therapy for angiosarcoma and other SFRP2 expressing cancers, and contribute to our understanding of the biology of SFRP2 during tumor development and progression.
Collapse
|
50
|
Sheeran PS, Dayton PA. Improving the performance of phase-change perfluorocarbon droplets for medical ultrasonography: current progress, challenges, and prospects. SCIENTIFICA 2014; 2014:579684. [PMID: 24991447 PMCID: PMC4058811 DOI: 10.1155/2014/579684] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Accepted: 04/02/2014] [Indexed: 05/12/2023]
Abstract
Over the past two decades, perfluorocarbon (PFC) droplets have been investigated for biomedical applications across a wide range of imaging modalities. More recently, interest has increased in "phase-change" PFC droplets (or "phase-change" contrast agents), which can convert from liquid to gas with an external energy input. In the field of ultrasound, phase-change droplets present an attractive alternative to traditional microbubble agents for many diagnostic and therapeutic applications. Despite the progress, phase-change PFC droplets remain far from clinical implementation due to a number of challenges. In this review, we survey our recent work to enhance the performance of phase-change agents for ultrasound through a variety of techniques in order to provide increased efficacy in therapeutic applications of ultrasound and enable previously unexplored applications in diagnostic and molecular imaging.
Collapse
Affiliation(s)
- Paul S. Sheeran
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, NC 27599, USA
| | - Paul A. Dayton
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, NC 27599, USA
- *Paul A. Dayton:
| |
Collapse
|