1
|
Dauda Usman J, Umar Isyaku M, Fasanmade AA. Evaluation of heart rate variability, blood pressure and lipid profile alterations from dual transceiver mobile phone radiation exposure. J Basic Clin Physiol Pharmacol 2020; 32:951-957. [PMID: 33146629 DOI: 10.1515/jbcpp-2020-0047] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 08/02/2020] [Indexed: 11/15/2022]
Abstract
OBJECTIVES Electromagnetic fields have been reported to alter electrical activities in the brain and heart. However, there is paucity of information on the potential functional alterations that magnetic fields from mobile phone could cause to the heart. This study investigated heart rate variability (HRV), blood pressure (BP) and lipid profile in Wistar rats exposed to electromagnetic field radiation from a dual transceiver mobile phone (DTrMP). METHODS Twenty-one male albino Wistar rats (140-180 g) were randomly assigned to two major groups positioned 5 m apart as follows: control: no phone (n=7) and treatment group (n=14) continuously exposed to electromagnetic field from Tecno T312 DTrMP 900/1800 MHz set in silence mode. Experimental treatment consisted in 10 min calls/day, directed to this device for a period of six weeks. Seven animals from the treatment group were allowed to recover for a period of two weeks after exposure. HRV, systolic, diastolic and mean arterial BP were noninvasively investigated, while serum lipid profile and heart tissue nitric oxide (NO) activities were determined using standard procedures. RESULTS There was significant (p<0.05) increase in systolic, diastolic, mean arterial BP and a decrease in HRV. Serum high density lipoproteins decreased, while total cholesterol, atherogenic indices, and heart NO levels increased significantly in the radiation exposed animals. The alterations observed in exposed animals remained unchanged even after the recovery period. CONCLUSIONS These results suggest that exposure to electromagnetic radiation from dual transceiver mobile phones could be a risk factor to increase in blood pressure.
Collapse
Affiliation(s)
- Jamil Dauda Usman
- Department of Human Physiology, College of Medicine and Health Sciences, Federal University Dutse, Dutse, Nigeria.,Department of Physiology, College of Medicine,University of Ibadan, Ibadan, Nigeria
| | - Mikail Umar Isyaku
- Department of Human Anatomy, College of Medicine and Health Sciences, Federal University Dutse, Dutse, Nigeria
| | | |
Collapse
|
2
|
Migault L, Bowman JD, Kromhout H, Figuerola J, Baldi I, Bouvier G, Turner MC, Cardis E, Vila J. Development of a Job-Exposure Matrix for Assessment of Occupational Exposure to High-Frequency Electromagnetic Fields (3 kHz-300 GHz). Ann Work Expo Health 2020; 63:1013-1028. [PMID: 31702767 DOI: 10.1093/annweh/wxz067] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Revised: 06/18/2019] [Accepted: 07/26/2019] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES The aim of this work was to build a job-exposure matrix (JEM) using an international coding system and covering the non-thermal intermediate frequency (IF) (3-100 kHz, named IFELF), thermal IF (100 kHz-10 MHz, named IFRF), and radiofrequency (RF) (>10 MHz) bands. METHODS Detailed occupational data were collected in a large population-based case-control study, INTEROCC, with occupations coded into the International Standard Classification of Occupations system 1988 (ISCO88). The subjects' occupational source-based ancillary information was combined with an existing source-exposure matrix and the reference levels of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) for occupational exposure to calculate estimates of level (L) of exposure to electric (E) and magnetic (H) fields by ISCO88 code and frequency band as ICNIRP ratios (IFELF) or squared ratios (IFRF and RF). Estimates of exposure probability (P) were obtained by dividing the number of exposed subjects by the total number of subjects available per job title. RESULTS With 36 011 job histories collected, 468 ISCO88 (four-digit) codes were included in the JEM, of which 62.4% are exposed to RF, IFRF, and/or IFELF. As a reference, P values for RF E-fields ranged from 0.3 to 65.0% with a median of 5.1%. L values for RF E-fields (ICNIRP squared ratio) ranged from 6.94 × 10-11 to 33.97 with a median of 0.61. CONCLUSIONS The methodology used allowed the development of a JEM for high-frequency electromagnetic fields containing exposure estimates for the largest number of occupations to date. Although the validity of this JEM is limited by the small number of available observations for some codes, this JEM may be useful for epidemiological studies and occupational health management programs assessing high-frequency electromagnetic field exposure in occupational settings.
Collapse
Affiliation(s)
- Lucile Migault
- University of Bordeaux, Inserm UMR 1219 EPICENE Team, Bordeaux Population Health Research Center, Bordeaux, France
| | | | - Hans Kromhout
- Environmental Epidemiology Division, Institute for Risk Assessment Sciences, Utrecht University, Nieuw Gildestein Yalelaan, Utrecht, The Netherlands
| | - Jordi Figuerola
- Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain.,Universitat Pompeu Fabra (UPF), Plaça de la Mercè, Barcelona, Spain
| | - Isabelle Baldi
- University of Bordeaux, Inserm UMR 1219 EPICENE Team, Bordeaux Population Health Research Center, Bordeaux, France.,Bordeaux University Hospital, Service de Médecine du Travail et pathologie professionnelle, Pessac, France
| | - Ghislaine Bouvier
- University of Bordeaux, Inserm UMR 1219 EPICENE Team, Bordeaux Population Health Research Center, Bordeaux, France
| | - Michelle C Turner
- Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain.,Universitat Pompeu Fabra (UPF), Plaça de la Mercè, Barcelona, Spain.,CIBER Epidemiologia y Salud Pública (CIBERESP), Av. Monforte de Lemos, Madrid, Spain.,McLaughlin Center for Population Health Risk Assessment, University of Ottawa, Ottawa, Canada
| | - Elisabeth Cardis
- Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain.,Universitat Pompeu Fabra (UPF), Plaça de la Mercè, Barcelona, Spain.,CIBER Epidemiologia y Salud Pública (CIBERESP), Av. Monforte de Lemos, Madrid, Spain
| | - Javier Vila
- Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain.,Universitat Pompeu Fabra (UPF), Plaça de la Mercè, Barcelona, Spain.,CIBER Epidemiologia y Salud Pública (CIBERESP), Av. Monforte de Lemos, Madrid, Spain.,Environmental Protection Agency (EPA), Office of Radiation Protection and Environmental Monitoring, McCumiskey House, Richview, Dublin, Ireland
| |
Collapse
|
4
|
Karpowicz J, Zradziński P, Kieliszek J, Gryz K, Sobiech J, Leszko W. An In Situ and In Silico Evaluation of Biophysical Effects of 27 MHz Electromagnetic Whole Body Humans Exposure Expressed by the Limb Current. BIOMED RESEARCH INTERNATIONAL 2017; 2017:5785482. [PMID: 28758119 PMCID: PMC5516722 DOI: 10.1155/2017/5785482] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Accepted: 05/16/2017] [Indexed: 12/02/2022]
Abstract
OBJECTIVES The aim was to evaluate correlations between biophysical effects of 27 MHz electromagnetic field exposure in humans (limb induced current (LIC)) and (1) parameters of affecting heterogeneous electric field and (2) body anthropometric properties, in order to improve the evaluation of electromagnetic environmental hazards. METHODS Biophysical effects of exposure were studied in situ by measurements of LIC in 24 volunteers (at the ankle) standing near radio communication rod antenna and in silico in 4 numerical body phantoms exposed near a model of antenna. RESULTS Strong, positive, statistically significant correlations were found in all exposure scenarios between LIC and body volume index (body height multiplied by mass) (r > 0.7; p < 0.001). The most informative exposure parameters, with respect to the evaluation of electromagnetic hazards by measurements (i.e., the ones strongest correlated with LIC), were found to be the value of electric field (unperturbed field, in the absence of body) in front of the chest (50 cm from body axis) or the maximum value in space occupied by human. Such parameters were not analysed in previous studies. CONCLUSIONS Exposed person's body volume and electric field strength in front of the chest determine LIC in studied exposure scenarios, but their wider applicability needs further studies.
Collapse
Affiliation(s)
- Jolanta Karpowicz
- Central Institute for Labour Protection-National Research Institute, Laboratory of Electromagnetic Hazards, Warszawa, Poland
| | - Patryk Zradziński
- Central Institute for Labour Protection-National Research Institute, Laboratory of Electromagnetic Hazards, Warszawa, Poland
| | - Jarosław Kieliszek
- Military Institute of Hygiene and Epidemiology, Laboratory of Electromagnetic Radiation Metrology, Warszawa, Poland
| | - Krzysztof Gryz
- Central Institute for Labour Protection-National Research Institute, Laboratory of Electromagnetic Hazards, Warszawa, Poland
| | - Jaromir Sobiech
- Military Institute of Hygiene and Epidemiology, Laboratory of Electromagnetic Radiation Metrology, Warszawa, Poland
| | - Wiesław Leszko
- Central Institute for Labour Protection-National Research Institute, Laboratory of Electromagnetic Hazards, Warszawa, Poland
| |
Collapse
|
5
|
Evaluation of exposure to electromagnetic radiofrequency radiation in the indoor workplace accessible to the public by the use of frequency-selective exposimeters. Int J Occup Med Environ Health 2014; 27:1043-54. [PMID: 25519944 DOI: 10.2478/s13382-014-0334-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2014] [Accepted: 06/19/2014] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVES The aim of the study was to identify and assess electromagnetic radiofrequency radiation (EMRR) exposure in a workplace located in a publicly accessible environment, and represented by offices (where exposure is caused by various transmitters of local fixed indoor and outdoor wireless communication systems). MATERIAL AND METHODS The investigations were performed in 45 buildings (in urban and rural areas in various regions of Poland), using frequency-selective electric field strength (E-field) exposimeters sensitive to the EMRR with a frequency range of 88-2500 MHz, split into 12 sub-bands corresponding to the operating frequencies of typical EMRR sources. The variability of the E-field was analyzed for each frequency range and the total level of exposure by statistical parameters of recorded exposimetric profiles: minimum, maximum, median values and 25-75th - percentiles. RESULTS The main sources of exposure to EMRR are mobile phone base transceiver stations (BTS) and radio-television transmitters (RTV). The frequency composition in a particular office depends on the building's location. The E-field recorded in buildings in urban and rural areas from the outdoor BTS did not exceed respectively: medians - 0.19 and 0.05 V/m, 75th percentiles -0.25 and 0.09 V/m. In buildings equipped with the indoor BTS antennas the E-field did not exceed: medians - 1 V/m, 75th percentiles - 1.8 V/m. Whereas in urban and rural areas, the median and 75th percentile values of the E-field recorded in buildings located near the RTV (within 1 km) did not exceed: 1.5 and 3.8 V/m or 0.4 and 0.8 V/m, for radio FM band or for TV bands, respectively. CONCLUSIONS Investigations confirmed the practical applicability of the exposimetric measurements technique for evaluating parameters of worker's exposure in both frequency- and time-domain. The presented results show EMRR exposure of workers or general public in locations comparable to offices to be well below international limits.
Collapse
|
6
|
Karpowicz J, Gryz K. An assessment of hazards caused by electromagnetic interaction on humans present near short-wave physiotherapeutic devices of various types including hazards for users of electronic active implantable medical devices (AIMD). BIOMED RESEARCH INTERNATIONAL 2013; 2013:150143. [PMID: 24089662 PMCID: PMC3780475 DOI: 10.1155/2013/150143] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Revised: 07/30/2013] [Accepted: 08/05/2013] [Indexed: 11/25/2022]
Abstract
Leakage of electromagnetic fields (EMF) from short-wave radiofrequency physiotherapeutic diathermies (SWDs) may cause health and safety hazards affecting unintentionally exposed workers (W) or general public (GP) members (assisting patient exposed during treatment or presenting there for other reasons). Increasing use of electronic active implantable medical devices (AIMDs), by patients, attendants, and workers, needs attention because dysfunctions of these devices may be caused by electromagnetic interactions. EMF emitted by 12 SWDs (with capacitive or inductive applicators) were assessed following international guidelines on protection against EMF exposure (International Commission on Nonionizing Radiation Protection for GP and W, new European directive 2013/35/EU for W, European Recommendation for GP, and European Standard EN 50527-1 for AIMD users). Direct EMF hazards for humans near inductive applicators were identified at a distance not exceeding 45 cm for W or 62 cm for GP, but for AIMD users up to 90 cm (twice longer than that for W and 50% longer than that for GP because EMF is pulsed modulated). Near capacitive applicators emitting continuous wave, the corresponding distances were: 120 cm for W or 150 cm for both-GP or AIMD users. This assessment does not cover patients who undergo SWD treatment (but it is usually recommended for AIMD users to be careful with EMF treatment).
Collapse
Affiliation(s)
- Jolanta Karpowicz
- Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection-National Research Institute (CIOP-PIB), Ulica Czerniakowska 16, 00-701 Warszawa, Poland
| | - Krzysztof Gryz
- Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection-National Research Institute (CIOP-PIB), Ulica Czerniakowska 16, 00-701 Warszawa, Poland
| |
Collapse
|