1
|
Ricci M, De Feo MS, Granese GM, Frantellizzi V, Carabellese B, Lubrano E, Cimini A. 18F-FDG PET/CT technology for the assessment of brown adipose tissue: an updated review. Expert Rev Med Devices 2023; 20:1143-1156. [PMID: 37965719 DOI: 10.1080/17434440.2023.2283618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 11/10/2023] [Indexed: 11/16/2023]
Abstract
INTRODUCTION This review provides an update of 18 F-fluorodeoxyglucose ([18F] FDG) for Brown adipose tissue (BAT) activity quantification, whose role is not completely understood. AREAS COVERED We conducted an unstructured search of the literature for any studies employing the [18F] FDG PET in BAT assessment. We explored BAT quantification both in healthy individuals and in different pathologies, after cold exposure and as a metabolic biomarker. The assessment of possible BAT modulators by using [18F] FDG PET is shown. Further PET tracers and novel developments for BAT assessments are also described. EXPERT OPINION Further PET tracers and imaging modalities are under investigation, but the [18F] FDG PET is currently the method of choice for the evaluation of BAT and further multicentric trials are needed for a better understanding of the BAT physiopathology, also after cold stimuli. The modulation of BAT activity, assessed by [18F] FDG PET imaging, seems a promising tool for the management of conditions such as obesity and type 2 diabetes. Moreover, an interesting possible correlation of BAT activation with prognostic [18F] FDG PET indices in cancer patients should be assessed with further multicentric trials.
Collapse
Affiliation(s)
- Maria Ricci
- Nuclear Medicine Unit, Cardarelli Hospital, Campobasso, Italy
| | - Maria Silvia De Feo
- Department of Radiological Sciences Oncology and Anatomo-Pathology, Sapienza University of Rome, Rome, Italy
| | - Giorgia Maria Granese
- Department of Radiological Sciences Oncology and Anatomo-Pathology, Sapienza University of Rome, Rome, Italy
| | - Viviana Frantellizzi
- Department of Radiological Sciences Oncology and Anatomo-Pathology, Sapienza University of Rome, Rome, Italy
| | | | - Ennio Lubrano
- Dipartimento di Medicina e Scienze della Salute, Università degli Studi del Molise, Italy
- Department of Development and Regeneration, Skeletal Biology and Engineering Research Center, KU Leuven, Leuven, Belgium
| | - Andrea Cimini
- Nuclear Medicine Unit, St. Salvatore Hospital, L'Aquila, Italy
| |
Collapse
|
2
|
Laskari K, Siores E, Tektonidou MM, Sfikakis PP. Microwave Radiometry for the Diagnosis and Monitoring of Inflammatory Arthritis. Diagnostics (Basel) 2023; 13:diagnostics13040609. [PMID: 36832097 PMCID: PMC9955117 DOI: 10.3390/diagnostics13040609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 02/03/2023] [Indexed: 02/11/2023] Open
Abstract
The ability of microwave radiometry (MWR) to detect with high accuracy in-depth temperature changes in human tissues is under investigation in various medical fields. The need for non-invasive, easily accessible imaging biomarkers for the diagnosis and monitoring of inflammatory arthritis provides the background for this application in order to detect the local temperature increase due to the inflammatory process by placing the appropriate MWR sensor on the skin over the joint. Indeed, a number of studies reviewed herein have reported interesting results, suggesting that MWR is useful for the differential diagnosis of arthritis as well as for the assessment of clinical and subclinical inflammation at the individual large or small joint level and the patient level. MWR showed higher agreement with musculoskeletal ultrasound, used as a reference, than with clinical examination in rheumatoid arthritis (RA), while it also appeared useful for the assessment of back pain and sacroiliitis. Further studies with a larger number of patients are warranted to confirm these findings, taking into account the current limitations of the available MWR devices. This may lead to the production of easily accessible and inexpensive MWR devices that will provide a powerful impetus for personalized medicine.
Collapse
Affiliation(s)
- Katerina Laskari
- Rheumatology Unit, 1st Department of Propaedeutic Internal Medicine, Joint Academic Rheumatology Program, University of Athens, Medical School, National & Kapodistrian University of Athens Medical School, 75 Mikras Asias Street, Goudi, 11527 Athens, Greece
- Correspondence: (K.L.); Tel.: +30-213-2061061; Fax: +30-210-7791839
| | - Elias Siores
- University of West Attica, 12243 Athens, Greece
- Institute of Materials Research and Innovation, University of Bolton, Bolton BL3 5AB, UK
| | - Maria M. Tektonidou
- Rheumatology Unit, 1st Department of Propaedeutic Internal Medicine, Joint Academic Rheumatology Program, University of Athens, Medical School, National & Kapodistrian University of Athens Medical School, 75 Mikras Asias Street, Goudi, 11527 Athens, Greece
| | - Petros P. Sfikakis
- Rheumatology Unit, 1st Department of Propaedeutic Internal Medicine, Joint Academic Rheumatology Program, University of Athens, Medical School, National & Kapodistrian University of Athens Medical School, 75 Mikras Asias Street, Goudi, 11527 Athens, Greece
| |
Collapse
|
3
|
Microminiaturization of Multichannel Multifrequency Radiographs. BIOMEDICAL ENGINEERING 2022; 56:225-229. [PMID: 36311439 PMCID: PMC9596336 DOI: 10.1007/s10527-022-10207-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Indexed: 11/07/2022]
Abstract
Due to the COVID-19 epidemic, the challenge of introducing methods for investigating patients reducing or eliminating the probability of infection of medical staff is currently relevant. This article provides an analytical review of new technological approaches to organizing the work of medical personnel in carrying out auscultation of patients with COVID-19. The development and approval of such technologies is shown to have started around the world. The ubiquitous and large-scale introduction of these methods into medical practice therefore seems expedient.
Collapse
|
4
|
Kalinke I, Kubbutat P, Taghian Dinani S, Ambros S, Ozcelik M, Kulozik U. Critical assessment of methods for measurement of temperature profiles and heat load history in microwave heating processes-A review. Compr Rev Food Sci Food Saf 2022; 21:2118-2148. [PMID: 35338578 DOI: 10.1111/1541-4337.12940] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 02/11/2022] [Accepted: 02/24/2022] [Indexed: 12/23/2022]
Abstract
Limitations of microwave processing due to inhomogeneities of power input and energy absorption have been widely described. Over- and underheated product areas influence reproducibility, product quality, and possibly safety. Although a broad range of methods is available for temperature measurement and evaluation of time/temperature effects, none of them is sufficiently able to detect temperature differences and thermally induced effects within the product caused by inhomogeneous heating. The purpose of this review is to critically assess different methods of temperature measurement for their suitability for different microwave applications, namely metallic temperature sensors, thermal imaging, pyrometer measurement, fiber optic sensors, microwave radiometry, magnetic resonance imaging, liquid crystal thermography, thermal paper, and biological and chemical time-temperature indicators. These methods are evaluated according to their advantages and limitations, method characteristics, and potential interference with the electric field. Special attention is given to spatial resolution, accuracy, handling, and purpose of measurement, that is, development work or online production control. Differences of methods and examples of practical application and failure in microwave-assisted food processing are discussed with a special focus on microwave pasteurization and microwave-assisted drying. Based on this assessment, it is suggested that infrared cameras for measuring temperature distribution at the product surface and partially inside the product in combination with a chemical time/temperature indicator (e.g., Maillard reaction, generating heat-induced color variations, depending on local energy absorption) appear to be the most appropriate system for future practical application in microwave food process control, microwave system development, and product design. Reliable detection of inhomogeneous heating is a prerequisite to counteracte inhomogeneity by a targeted adjustment of process and product parameters in microwave applications.
Collapse
Affiliation(s)
- Isabel Kalinke
- Food and Bioprocess Engineering, TUM School of Life Sciences, Technical University Munich, Freising, Germany
| | - Peter Kubbutat
- Food and Bioprocess Engineering, TUM School of Life Sciences, Technical University Munich, Freising, Germany
| | - Somayeh Taghian Dinani
- Food and Bioprocess Engineering, TUM School of Life Sciences, Technical University Munich, Freising, Germany
| | - Sabine Ambros
- Food and Bioprocess Engineering, TUM School of Life Sciences, Technical University Munich, Freising, Germany
| | - Mine Ozcelik
- Food and Bioprocess Engineering, TUM School of Life Sciences, Technical University Munich, Freising, Germany
| | - Ulrich Kulozik
- Food and Bioprocess Engineering, TUM School of Life Sciences, Technical University Munich, Freising, Germany
| |
Collapse
|
5
|
Cai J, Jiang S, Quan Y, Lin J, Zhu S, Wang J, Jiang W, Liao Y, Lu F. Skeletal muscle provides a pro-browning microenvironment for transplanted brown adipose tissue to maintain its effect to ameliorate obesity in ob/ob mice. FASEB J 2021; 36:e22056. [PMID: 34939223 DOI: 10.1096/fj.202101144r] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 10/22/2021] [Accepted: 11/08/2021] [Indexed: 12/11/2022]
Abstract
Brown adipose tissue (BAT) transplantation is a promising means of increasing whole-body energy metabolism to ameliorate obesity. However, the changes in BAT following transplantation and the effects of the microenvironment of the recipient site on graft function have yet to be fully characterized. Therefore, we aimed to determine the effects of transplanting BAT from C57BL/6 mice into the dorsal subcutaneous region or deep to the quadriceps femoris muscle of leptin-deficient ob/ob mice. Subcutaneously transplanted BAT lost features of BAT and demonstrated greater inflammatory cell infiltration and more oil cysts 16 weeks following transplantation. By contrast, the sub-muscularly transplanted BAT maintained features of BAT and was more highly vascularized. Interestingly, sub-muscular BAT transplantation led to a significant increase in oxygen consumption and less inflammation in subcutaneous fat, which was associated with long-term reductions in insulin resistance and body mass gain, whereas the subcutaneous transplants failed after 16 weeks. These results demonstrate that the beneficial effects of BAT transplantation depend upon the microenvironment of the recipient site. Skeletal muscle may provide a microenvironment that maintains the inherent features of BAT grafts over a long period of time, which facilitates a reduction in obesity and improvements in glucose homeostasis.
Collapse
Affiliation(s)
- Junrong Cai
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Shenglu Jiang
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China.,Department of Plastic Surgery, Taizhou Central Hospital, Taizhou University, Taizhou, China
| | - Yuping Quan
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Jiayan Lin
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Shaowei Zhu
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Jing Wang
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Wenqing Jiang
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Yunjun Liao
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Feng Lu
- Department of Plastic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China
| |
Collapse
|
6
|
Santhanam P, Rowe SP, Solnes LB, Quainoo B, Ahima RS. A systematic review of imaging studies of human brown adipose tissue. Ann N Y Acad Sci 2021; 1495:5-23. [PMID: 33604891 DOI: 10.1111/nyas.14579] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Revised: 01/25/2021] [Accepted: 01/31/2021] [Indexed: 02/06/2023]
Abstract
Brown adipose tissue (BAT) is involved in energy dissipation and has been linked to weight loss, insulin sensitivity, and reduced risk of atherosclerotic disease. BAT is found most often in the supraclavicular region, as well as mediastinal and paravertebral areas, and it is predominantly seen in young persons. BAT is activated by cold temperature and the sympathetic nervous system. In humans, BAT was initially detected via 2-deoxy-2-[18 F]fluoro-d-glucose (FDG) positron emission tomography/computed tomography (PET/CT), a high-resolution molecular imaging modality used to identify and stage malignancies. Recent studies have shown that BAT can be localized using conventional imaging modalities, such as CT or magnetic resonance imaging, as well as radiotracers used for single-photon emission CT. In this systematic review, we have summarized the evidence for BAT detection in humans using various imaging techniques.
Collapse
Affiliation(s)
- Prasanna Santhanam
- Division of Endocrinology, Diabetes, and Metabolism, Department of Medicine, Johns Hopkins University School of Medicine, Asthma and Allergy Center, Baltimore, Maryland
| | - Steven P Rowe
- Division of Nuclear Medicine, Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Lilja B Solnes
- Division of Nuclear Medicine, Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Brittany Quainoo
- Columbian College of Arts and Sciences, George Washington University, Washington, DC
| | - Rexford S Ahima
- Division of Endocrinology, Diabetes, and Metabolism, Department of Medicine, Johns Hopkins University School of Medicine, Asthma and Allergy Center, Baltimore, Maryland
| |
Collapse
|
7
|
Niu N, Xing H, Wang X, Ding J, Hao Z, Ren C, Ba J, Zheng L, Fu C, Zhao H, Huo L. Comparative [ 18F]FDG and [ 18F]DPA714 PET imaging and time-dependent changes of brown adipose tissue in tumour-bearing mice. Adipocyte 2020; 9:542-549. [PMID: 32902340 PMCID: PMC7714432 DOI: 10.1080/21623945.2020.1814546] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Brown adipose tissue (BAT) is important in monitoring energy homeostasis and cancer cachexia. Different from white adipose tissue, BAT is characterized by the presence of a large number of mitochondria in adipocytes. Translocator protein 18 kDa (TSPO), a critical transporter, is expressed in the outer membrane of mitochondria. We speculated that [18F]DPA714, a specific TSPO tracer, may monitor BAT activity in tumor-bearing mice in vivo. We first analyzed the radioactive uptake of positron emission tomography (PET) tracers in BAT of CT26 xenograft mice with 18F-fluorodeoxyglucose ([18F]FDG) and [18F]DPA714. We also studied the BAT uptake of [18F]DPA714 in CT26, A549 and LLC tumor models. The dynamic distribution of [18F]FDG is quite variable among animals, even in mice of the same tumor model (%ID/g-mean: mean ± SDM, 8.61 ± 8.90, n = 16). Contrarily, [18F]DPA714 produced high-quality and stable BAT imaging in different tumor models and different animals of the same model. Interestingly, %ID/g-mean of [18F]DPA714 in BAT was significantly higher on day 26 than that on day 7 in CT26 xenograft model. Taken together, these results strongly indicate the potential feasibility of [18F]DPA714 PET imaging in investigating BAT and energy metabolism during tumor progression in preclinical and clinical study.
Collapse
Affiliation(s)
- Na Niu
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| | - Haiqun Xing
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| | - Xuezhu Wang
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| | - Jie Ding
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| | - Zhixin Hao
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| | - Chao Ren
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| | - Jiantao Ba
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| | - Lianfang Zheng
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| | - Chao Fu
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| | - Haiyan Zhao
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| | - Li Huo
- Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), Beijing, China
| |
Collapse
|
8
|
Functional characterization of human brown adipose tissue metabolism. Biochem J 2020; 477:1261-1286. [PMID: 32271883 DOI: 10.1042/bcj20190464] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Revised: 03/13/2020] [Accepted: 03/16/2020] [Indexed: 02/07/2023]
Abstract
Brown adipose tissue (BAT) has long been described according to its histological features as a multilocular, lipid-containing tissue, light brown in color, that is also responsive to the cold and found especially in hibernating mammals and human infants. Its presence in both hibernators and human infants, combined with its function as a heat-generating organ, raised many questions about its role in humans. Early characterizations of the tissue in humans focused on its progressive atrophy with age and its apparent importance for cold-exposed workers. However, the use of positron emission tomography (PET) with the glucose tracer [18F]fluorodeoxyglucose ([18F]FDG) made it possible to begin characterizing the possible function of BAT in adult humans, and whether it could play a role in the prevention or treatment of obesity and type 2 diabetes (T2D). This review focuses on the in vivo functional characterization of human BAT, the methodological approaches applied to examine these features and addresses critical gaps that remain in moving the field forward. Specifically, we describe the anatomical and biomolecular features of human BAT, the modalities and applications of non-invasive tools such as PET and magnetic resonance imaging coupled with spectroscopy (MRI/MRS) to study BAT morphology and function in vivo, and finally describe the functional characteristics of human BAT that have only been possible through the development and application of such tools.
Collapse
|
9
|
Goryanin I, Karbainov S, Shevelev O, Tarakanov A, Redpath K, Vesnin S, Ivanov Y. Passive microwave radiometry in biomedical studies. Drug Discov Today 2020; 25:757-763. [PMID: 32004473 DOI: 10.1016/j.drudis.2020.01.016] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 12/21/2019] [Accepted: 01/22/2020] [Indexed: 01/30/2023]
Abstract
Passive microwave radiometry (MWR) measures natural emissions in the range 1-10GHz from proteins, cells, organs and the whole human body. The intensity of intrinsic emission is determined by biochemical and biophysical processes. The nature of this process is still not very well known. Infrared thermography (IRT) can detect emission several microns deep (skin temperature), whereas MWR allows detection of thermal abnormalities down to several centimeters (internal or deep temperature). MWR is noninvasive and inexpensive. It requires neither fluorescent nor radioactive labels, nor ionizing or other radiation. MWR can be used in early drug discovery as well as preclinical and clinical studies.
Collapse
Affiliation(s)
- Igor Goryanin
- University of Edinburgh, UK; Okinawa Institute Science and Technology, Okinawa, Japan; Tianjin Institute of Industrial Biotechnology, Tianjin, China.
| | | | - Oleg Shevelev
- Peoples' Friendship University of Russia, Moscow, Russia
| | | | - Keith Redpath
- Manus Neurodynamica, Edinburgh, UK; Medical Microwave Radiometry (MMWR), Edinburgh, UK
| | - Sergey Vesnin
- Medical Microwave Radiometry (MMWR), Edinburgh, UK; Bauman Moscow State Technical University (BMSTU), Moscow, Russia
| | - Yuri Ivanov
- Institute of Biomedical Chemistry (IBMC), Moscow, Russia; Joint Institute for High Temperatures of the RAS, Moscow, Russia
| |
Collapse
|
10
|
Ravi VM, Sharma AK, Arunachalam K. Pre-Clinical Testing of Microwave Radiometer and a Pilot Study on the Screening Inflammation of Knee Joints. Bioelectromagnetics 2019; 40:402-411. [PMID: 31310336 DOI: 10.1002/bem.22203] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Accepted: 06/12/2019] [Indexed: 11/10/2022]
Abstract
This article presents the pre-clinical evaluation of our custom-built, single-band microwave radiometer centered at 1.3 GHz for deep tissue thermometry, and a pilot study on volunteers for passive detection of inflammation in knee joints. The electromagnetic (EM) compatibility of the battery-operated radiometer for clinical use was assessed as per International Special Committee on Radio Interference (CISPR) 22 standard. The ability to detect inflammation in knee joints was assessed using a substrate integrated waveguide antenna connected to the radiometer. EM compatibility tests carried out in the laboratory indicated device immunity to intentional radiated interference up to -20 dBm injected power in the global system for mobile communication frequency band, and pre-compliance to CISPR 22 standard. Radiometer temperature measurements recorded at the lateral and medial aspects of both knees of 41 volunteers indicated mean temperature greater than 33°C for the diseased sites compared with the mean temperature of 28°C measured for the healthy sites. One-way analysis of variance statistics indicated significantly (P < 0.005) higher radiometer temperature at the diseased sites unlike the healthy sites. Thus, the EM pre-compliance of the device and the potential to measure deep tissue inflammation were demonstrated. Bioelectromagnetics. 2019;40:402-411. © 2019 Bioelectromagnetics Society.
Collapse
Affiliation(s)
- Vidyalakshmi M Ravi
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai, India
| | - Amit K Sharma
- Institute Hospital, Indian Institute of Technology Madras, Chennai, India
| | - Kavitha Arunachalam
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai, India
| |
Collapse
|
11
|
Fraum TJ, Crandall JP, Ludwig DR, Chen S, Fowler KJ, Laforest RA, Salter A, Dehdashti F, An H, Wahl RL. Repeatability of Quantitative Brown Adipose Tissue Imaging Metrics on Positron Emission Tomography with 18F-Fluorodeoxyglucose in Humans. Cell Metab 2019; 30:212-224.e4. [PMID: 31230985 DOI: 10.1016/j.cmet.2019.05.019] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Revised: 03/01/2019] [Accepted: 05/22/2019] [Indexed: 01/09/2023]
Abstract
Brown adipose tissue (BAT) is a promising target for anti-obesity interventions. This prospective test-retest study assessed the repeatability of several important quantitative BAT metrics. After cold activation, 24 subjects underwent positron emission tomography (PET)/computed tomography (CT) and PET/magnetic resonance imaging (MRI), utilizing 18F-fluorodeoxyglucose. Repeat imaging occurred within 14 days per an identical protocol. BAT volumes were strongly correlated between sessions for PET/CT (intraclass correlation coefficient [ICC], 0.85) and PET/MRI (ICC, 0.82). BAT maximum lean-body-mass-adjusted standardized uptake values (SULmax) were also strongly correlated between sessions for both PET/CT (ICC, 0.74) and PET/MRI (ICC, 0.83). Much longitudinal variability in BAT metrics was likely due to biological factors intrinsic to BAT, whole-body metabolic fluctuations, or temporal differences in cold-activation efficacy, rather than imaging factors. Future studies utilizing these imaging metrics to track the response BAT to interventions should incorporate this variation into sample-size considerations and response criteria.
Collapse
Affiliation(s)
- Tyler J Fraum
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
| | - John P Crandall
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
| | - Daniel R Ludwig
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
| | - Sihao Chen
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
| | - Kathryn J Fowler
- Department of Radiology, University of California, San Diego School of Medicine, San Diego, CA, USA
| | - Richard A Laforest
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
| | - Amber Salter
- Division of Biostatistics, Washington University School of Medicine, St. Louis, MO, USA
| | - Farrokh Dehdashti
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
| | - Hongyu An
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
| | - Richard L Wahl
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA.
| |
Collapse
|
12
|
Carpentier AC, Blondin DP, Virtanen KA, Richard D, Haman F, Turcotte ÉE. Brown Adipose Tissue Energy Metabolism in Humans. Front Endocrinol (Lausanne) 2018; 9:447. [PMID: 30131768 PMCID: PMC6090055 DOI: 10.3389/fendo.2018.00447] [Citation(s) in RCA: 197] [Impact Index Per Article: 32.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 07/20/2018] [Indexed: 12/16/2022] Open
Abstract
The demonstration of metabolically active brown adipose tissue (BAT) in humans primarily using positron emission tomography coupled to computed tomography (PET/CT) with the glucose tracer 18-fluorodeoxyglucose (18FDG) has renewed the interest of the scientific and medical community in the possible role of BAT as a target for the prevention and treatment of obesity and type 2 diabetes (T2D). Here, we offer a comprehensive review of BAT energy metabolism in humans. Considerable advances in methods to measure BAT energy metabolism, including nonesterified fatty acids (NEFA), chylomicron-triglycerides (TG), oxygen, Krebs cycle rate, and intracellular TG have led to very good quantification of energy substrate metabolism per volume of active BAT in vivo. These studies have also shown that intracellular TG are likely the primary energy source of BAT upon activation by cold. Current estimates of BAT's contribution to energy expenditure range at the lower end of what would be potentially clinically relevant if chronically sustained. Yet, 18FDG PET/CT remains the gold-standard defining method to quantify total BAT volume of activity, used to calculate BAT's total energy expenditure. Unfortunately, BAT glucose metabolism better reflects BAT's insulin sensitivity and blood flow. It is now clear that most glucose taken up by BAT does not fuel mitochondrial oxidative metabolism and that BAT glucose uptake can therefore be disconnected from thermogenesis. Furthermore, BAT thermogenesis is efficiently recruited upon repeated cold exposure, doubling to tripling its total oxidative capacity, with reciprocal reduction of muscle thermogenesis. Recent data suggest that total BAT volume may be much larger than the typically observed 50-150 ml with 18FDG PET/CT. Therefore, the current estimates of total BAT thermogenesis, largely relying on total BAT volume using 18FDG PET/CT, may underestimate the true contribution of BAT to total energy expenditure. Quantification of the contribution of BAT to energy expenditure begs for the development of more integrated whole body in vivo methods.
Collapse
Affiliation(s)
- André C. Carpentier
- Division of Endocrinology, Department of Medicine, Centre de Recherche du CHUS, Université de Sherbrooke, Sherbrooke, QC, Canada
| | | | - Kirsi A. Virtanen
- Turku PET Centre, Turku University Hospital, Turku, Finland
- Institute of Public Health and Clinical Nutrition, University of Eastern Finland (UEF), Kuopio, Finland
| | - Denis Richard
- Centre de Recherche de l'Institut Universitaire de Cardiologie et de Pneumologie de Québec, Université Laval, Quebec City, QC, Canada
| | - François Haman
- Faculty of Health Sciences, University of Ottawa, Ottawa, ON, Canada
| | - Éric E. Turcotte
- Department of Nuclear Medicine and Radiobiology, Centre de Recherche du CHUS, Université de Sherbrooke, Sherbrooke, QC, Canada
| |
Collapse
|
13
|
Chondronikola M, Beeman SC, Wahl RL. Non-invasive methods for the assessment of brown adipose tissue in humans. J Physiol 2018; 596:363-378. [PMID: 29119565 PMCID: PMC5792561 DOI: 10.1113/jp274255] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 10/04/2017] [Indexed: 01/10/2023] Open
Abstract
Brown adipose tissue (BAT) is a recently rediscovered tissue in people that has shown promise as a potential therapeutic target against obesity and its metabolic abnormalities. Reliable non-invasive assessment of BAT volume and activity is critical to allow its importance in metabolic control to be evaluated. Positron emission tomography/computed tomography (PET/CT) in combination with 2-deoxy-2-[18 F]fluoroglucose administration is currently the most frequently used and most established method for the detection and quantification of activated BAT in humans. However, it involves radiation exposure and can detect activated (e.g. after cold exposure), but not quiescent, BAT. Several alternative methods that overcome some of these limitations have been developed including different PET approaches, single-photon emission imaging, CT, magnetic resonance based approaches, contrast-enhanced ultrasound, near infrared spectroscopy, and temperature assessment of fat depots containing brown adipocytes. The purpose of this review is to summarize and critically evaluate the currently available methods that non-invasively probe various aspects of BAT biology in order to assess BAT volume and/or metabolism. Although several of these methods show promise for the non-invasive assessment of BAT volume and function, further research is needed to optimize them to enable an accurate, reproducible and practical means for the assessment of human BAT content and its metabolic function.
Collapse
Affiliation(s)
- Maria Chondronikola
- Center for Human NutritionWashington University School of MedicineSt LouisMOUSA
- Harokopio University of AthensAthensGreece
| | - Scott C. Beeman
- Department of Radiology, Mallinckrodt Institute of RadiologyWashington University School of MedicineSt LouisMOUSA
| | - Richard L. Wahl
- Department of Radiology, Mallinckrodt Institute of RadiologyWashington University School of MedicineSt LouisMOUSA
- Department of Radiation Oncology, Mallinckrodt Institute of RadiologyWashington University School of MedicineSt LouisMOUSA
| |
Collapse
|