Koomen DC, May JC, McLean JA. Insights and prospects for ion mobility-mass spectrometry in clinical chemistry. Expert Rev Proteomics 2022; 19:17-31. [PMID: 34986717 PMCID: PMC8881341 DOI: 10.1080/14789450.2022.2026218] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
INTRODUCTION Ion mobility-mass spectrometry is an emerging technology in the clinical setting for high throughput and high confidence molecular characterization from complex biological samples. Ion mobility spectrometry can provide isomer separations on the basis of molecular structure, the ability of which is increasing through technological developments that afford enhanced resolving power. Integrating multiple separation dimensions, such as liquid chromatography-ion mobility-mass spectrometry (LC-IM-MS) provide dramatic enhancements in the mitigation of molecular interferences for high accuracy clinical measurements. AREAS COVERED Multidimensional separations with LC-IM-MS provide better selectivity and sensitivity in molecular analysis. Mass spectrometry imaging of tissues to inform spatial molecular distribution is improved by complementary ion mobility analyses. Biomarker identification in surgical environments is enhanced by intraoperative biochemical analysis with mass spectrometry and holds promise for integration with ion mobility spectrometry. New prospects in high resolving power ion mobility are enhancing analysis capabilities, such as distinguishing isomeric compounds. EXPERT OPINION Ion mobility-mass spectrometry holds many prospects for the field of isomer identification, molecular imaging, and intraoperative tumor margin delineation in clinical settings. These advantages are afforded while maintaining fast analysis times and subsequently high throughput. High resolving power ion mobility will enhance these advantages further, in particular for analyses requiring high confidence isobaric selectivity and detection.
Collapse
Affiliation(s)
- David C. Koomen
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - Jody C. May
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - John A. McLean
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
2
|
Simon D, Oleschuk R. The liquid micro junction-surface sampling probe (LMJ-SSP); a versatile ambient mass spectrometry interface. Analyst 2021; 146:6365-6378. [PMID: 34553725 DOI: 10.1039/d1an00725d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Ambient ionization methods have become important tools in mass spectrometry. The LMJ-SSP can significantly simplify/reduce lengthy sample preparation requirements associated with mass spectrometry analysis. Samples may be introduced through direct contact, insertion and droplet injection, enabling applications from drug discovery and surface analysis to tissue profiling and metabolic mapping. This review examines the underlying principles associated with the LMJ-SSP interface and highlights modifications of the original design that have extended its capability. We summarize different application areas that have exploited the method and describe potential future directions for the adaptable ambient ionization source.
Collapse
Affiliation(s)
- David Simon
- Department of Chemistry, Queen's University, Kingston, Ontario, K7L 3N6, Canada.
| | - Richard Oleschuk
- Department of Chemistry, Queen's University, Kingston, Ontario, K7L 3N6, Canada.
| |
Collapse
|
3
|
Sans M, Krieger A, Wygant BR, Garza KY, Mullins CB, Eberlin LS. Spatially Controlled Molecular Analysis of Biological Samples Using Nanodroplet Arrays and Direct Droplet Aspiration. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:418-428. [PMID: 32031393 DOI: 10.1021/jasms.9b00077] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Mass spectrometry (MS) has emerged as a valuable technology for molecular and spatial evaluation of biological samples. Ambient ionization MS techniques, in particular, allow direct analysis of tissue samples with minimal pretreatment. Here, we describe the design and optimization of an alternative ambient liquid extraction MS approach for metabolite and lipid profiling and imaging from biological samples. The system combines a piezoelectric picoliter dispenser to form solvent nanodroplets onto the sample surface with controlled and tunable spatial resolution and a conductive capillary to directly aspirate/ionize the nanodroplets for efficient analyte transmission and detection. Using this approach, we performed spatial profiling of mouse brain tissue sections with different droplet sizes (390, 420, and 500 μm). MS analysis of normal and cancerous human brain and ovarian tissues yielded rich metabolic profiles that were characteristic of disease state and enabled visualization of tissue regions with different histologic composition. This method was also used to analyze the lipid profiles of human ovarian cell lines. Overall, our results demonstrate the capabilities of this system for spatially controlled MS analysis of biological samples.
Collapse
Affiliation(s)
- Marta Sans
- Department of Chemistry , University of Texas at Austin , Austin , Texas 78712 , United States
| | - Anna Krieger
- Department of Chemistry , University of Texas at Austin , Austin , Texas 78712 , United States
| | - Bryan R Wygant
- Department of Chemistry , University of Texas at Austin , Austin , Texas 78712 , United States
| | - Kyana Y Garza
- Department of Chemistry , University of Texas at Austin , Austin , Texas 78712 , United States
| | - C Buddie Mullins
- Department of Chemistry , University of Texas at Austin , Austin , Texas 78712 , United States
- McKetta Department of Chemical Engineering , University of Texas at Austin , Austin , Texas 78712 United States
| | - Livia S Eberlin
- Department of Chemistry , University of Texas at Austin , Austin , Texas 78712 , United States
| |
Collapse
|
4
|
Oberlies NH, Knowles SL, Amrine CSM, Kao D, Kertesz V, Raja HA. Droplet probe: coupling chromatography to the in situ evaluation of the chemistry of nature. Nat Prod Rep 2019; 36:944-959. [PMID: 31112181 PMCID: PMC6640111 DOI: 10.1039/c9np00019d] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Covering: up to 2019The chemistry of nature can be beautiful, inspiring, beneficial and poisonous, depending on perspective. Since the isolation of the first secondary metabolites roughly two centuries ago, much of the chemical research on natural products has been both reductionist and static. Typically, compounds were isolated and characterized from the extract of an entire organism from a single time point. While there could be subtexts to that approach, the general premise has been to determine the chemistry with very little in the way of tools to differentiate spatial and/or temporal changes in secondary metabolite profiles. However, the past decade has seen exponential advances in our ability to observe, measure, and visualize the chemistry of nature in situ. Many of those techniques have been reviewed in this journal, and most are tapping into the power of mass spectrometry to analyze a plethora of sample types. In nearly all of the other techniques used to study chemistry in situ, the element of chromatography has been eliminated, instead using various ionization sources to coax ions of the secondary metabolites directly into the mass spectrometer as a mixture. Much of that science has been driven by the great advances in ambient ionization techniques used with a suite of mass spectrometry platforms, including the alphabet soup from DESI to LAESI to MALDI. This review discusses the one in situ analysis technique that incorporates chromatography, being the droplet-liquid microjunction-surface sampling probe, which is more easily termed "droplet probe". In addition to comparing and contrasting the droplet probe with other techniques, we provide perspective on why scientists, particularly those steeped in natural products chemistry training, may want to include chromatography in in situ analyses. Moreover, we provide justification for droplet sampling, especially for samples with delicate and/or non-uniform topographies. Furthermore, while the droplet probe has been used the most in the analysis of fungal cultures, we digest a variety of other applications, ranging from cyanobacteria, to plant parts, and even delicate documents, such as herbarium specimens.
Collapse
Affiliation(s)
- Nicholas H Oberlies
- Department of Chemistry & Biochemistry, University of North Carolina at Greensboro, Greensboro, North Carolina, USA.
| | - Sonja L Knowles
- Department of Chemistry & Biochemistry, University of North Carolina at Greensboro, Greensboro, North Carolina, USA.
| | - Chiraz Soumia M Amrine
- Department of Chemistry & Biochemistry, University of North Carolina at Greensboro, Greensboro, North Carolina, USA.
| | - Diana Kao
- Department of Chemistry & Biochemistry, University of North Carolina at Greensboro, Greensboro, North Carolina, USA.
| | - Vilmos Kertesz
- Mass Spectrometry and Laser Spectroscopy Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA
| | - Huzefa A Raja
- Department of Chemistry & Biochemistry, University of North Carolina at Greensboro, Greensboro, North Carolina, USA.
| |
Collapse
|
5
|
Mourino-Alvarez L, Baldan-Martin M, Rincon R, Martin-Rojas T, Corbacho-Alonso N, Sastre-Oliva T, Barderas MG. Recent advances and clinical insights into the use of proteomics in the study of atherosclerosis. Expert Rev Proteomics 2017; 14:701-713. [PMID: 28689450 DOI: 10.1080/14789450.2017.1353912] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
INTRODUCTION The application of new proteomics methods may help to identify new diagnostic/predictive molecular markers in an attempt to improve the clinical management of atherosclerosis. Areas covered: Technological advances in proteomics have enhanced its sensitivity and multiplexing capacity, as well as the possibility of studying protein interactions and tissue structure. These advances will help us better understand the molecular mechanisms at play in atherosclerosis as a biological system. Moreover, this should help identify new predictive/diagnostic biomarkers and therapeutic targets that may facilitate effective risk stratification and early diagnosis, with the ensuing rapid implementation of treatment. This review provides a comprehensive overview of the novel methods in proteomics, including state-of-the-art techniques, novel biological samples and applications for the study of atherosclerosis. Expert commentary: Collaboration between clinicians and researchers is crucial to further validate and introduce new molecular markers to manage atherosclerosis that are identified using the most up to date proteomic approaches.
Collapse
Affiliation(s)
- Laura Mourino-Alvarez
- a Department of Vascular Physiopathology , Hospital Nacional de Paraplejicos , Toledo , Spain
| | | | - Raul Rincon
- a Department of Vascular Physiopathology , Hospital Nacional de Paraplejicos , Toledo , Spain
| | - Tatiana Martin-Rojas
- a Department of Vascular Physiopathology , Hospital Nacional de Paraplejicos , Toledo , Spain
| | - Nerea Corbacho-Alonso
- a Department of Vascular Physiopathology , Hospital Nacional de Paraplejicos , Toledo , Spain
| | - Tamara Sastre-Oliva
- a Department of Vascular Physiopathology , Hospital Nacional de Paraplejicos , Toledo , Spain
| | - Maria G Barderas
- a Department of Vascular Physiopathology , Hospital Nacional de Paraplejicos , Toledo , Spain
| |
Collapse
|
6
|
Xu LX, Wang TT, Geng YY, Wang WY, Li Y, Duan XK, Xu B, Liu CC, Liu WH. The direct analysis of drug distribution of rotigotine-loaded microspheres from tissue sections by LESA coupled with tandem mass spectrometry. Anal Bioanal Chem 2017; 409:5217-5223. [DOI: 10.1007/s00216-017-0440-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2017] [Revised: 05/17/2017] [Accepted: 05/30/2017] [Indexed: 10/19/2022]
|
7
|
Chen X, Hatsis P, Judge J, Argikar UA, Ren X, Sarber J, Mansfield K, Liang G, Amaral A, Catoire A, Bentley A, Ramos L, Moench P, Hintermann S, Carcache D, Glick J, Flarakos J. Compound Property Optimization in Drug Discovery Using Quantitative Surface Sampling Micro Liquid Chromatography with Tandem Mass Spectrometry. Anal Chem 2016; 88:11813-11820. [PMID: 27797491 DOI: 10.1021/acs.analchem.6b03449] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Surface sampling micro liquid chromatography tandem mass spectrometry (SSμLC-MS/MS) was explored as a quantitative tissue distribution technique for probing compound properties in drug discovery. A method was developed for creating standard curves using surrogate tissue sections from blank tissue homogenate spiked with compounds. The resulting standard curves showed good linearity and high sensitivity. The accuracy and precision of standards met acceptance criteria of ±30%. A new approach was proposed based on an experimental and mathematical method for tissue extraction efficiency evaluation by means of consecutively sampling a location on tissue twice by SSμLC-MS/MS. The observed extraction efficiency ranged from 69% to 82% with acceptable variation for the test compounds. Good agreement in extraction efficiency was observed between surrogate tissue sections and incurred tissue sections. This method was successfully applied to two case studies in which tissue distribution was instrumental in advancing project teams' understanding of compound properties.
Collapse
Affiliation(s)
| | - Panos Hatsis
- Drug Metabolism & Pharmacokinetics, Novartis Institutes for BioMedical Research, Inc. 1 Health Plaza, East Hanover, New Jersey 07936 United States
| | | | | | - Xiaojun Ren
- Drug Metabolism & Pharmacokinetics, Novartis Institutes for BioMedical Research, Inc. 1 Health Plaza, East Hanover, New Jersey 07936 United States
| | | | | | | | | | - Alexandre Catoire
- Drug Metabolism & Pharmacokinetics, Novartis Institutes for BioMedical Research, Inc. 1 Health Plaza, East Hanover, New Jersey 07936 United States
| | - Adam Bentley
- Drug Metabolism & Pharmacokinetics, Novartis Institutes for BioMedical Research, Inc. 1 Health Plaza, East Hanover, New Jersey 07936 United States
| | - Luis Ramos
- Drug Metabolism & Pharmacokinetics, Novartis Institutes for BioMedical Research, Inc. 1 Health Plaza, East Hanover, New Jersey 07936 United States
| | - Paul Moench
- Drug Metabolism & Pharmacokinetics, Novartis Institutes for BioMedical Research, Inc. 1 Health Plaza, East Hanover, New Jersey 07936 United States
| | - Samuel Hintermann
- Global Discovery Chemistry, Novartis Institutes for BioMedical Research, Inc. 4056 Basel, Switzerland
| | - David Carcache
- Global Discovery Chemistry, Novartis Institutes for BioMedical Research, Inc. 4056 Basel, Switzerland
| | - Jim Glick
- Drug Metabolism & Pharmacokinetics, Novartis Institutes for BioMedical Research, Inc. 1 Health Plaza, East Hanover, New Jersey 07936 United States
| | - Jimmy Flarakos
- Drug Metabolism & Pharmacokinetics, Novartis Institutes for BioMedical Research, Inc. 1 Health Plaza, East Hanover, New Jersey 07936 United States
| |
Collapse
|
8
|
Kertesz V, Weiskittel TM, Vavrek M, Freddo C, Van Berkel GJ. Extraction efficiency and implications for absolute quantitation of propranolol in mouse brain, liver and kidney tissue sections using droplet-based liquid microjunction surface sampling high-performance liquid chromatography/electrospray ionization tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:1705-1712. [PMID: 28328034 DOI: 10.1002/rcm.7607] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Revised: 05/12/2016] [Accepted: 05/13/2016] [Indexed: 06/06/2023]
Abstract
RATIONALE Currently, the absolute quantitation aspects of droplet-based surface sampling for tissue analysis using a fully automated autosampler/high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) system have not been fully evaluated. Knowledge of extraction efficiency and its reproducibility is required to judge the potential of the method for absolute quantitation of analytes from tissue sections. METHODS Adjacent tissue sections of propranolol-dosed mouse brain (10-μm-thick), kidney (10-μm-thick) and liver (8-, 10-, 16- and 24-μm-thick) were obtained. The absolute concentration of propranolol was determined in tissue punches from serial sections using standard bulk tissue extraction protocols and subsequent HPLC separations and MS/MS analysis. These values were used to determine propranolol extraction efficiency from the tissues with the droplet-based surface sampling approach. RESULTS Extraction efficiency of propranolol using 10-μm-thick brain, kidney and liver tissues using droplet-based surface sampling varied between ~45 and 63%. The extraction efficiency decreased from ~65% to ~36% with liver thickness increasing from 8 μm to 24 μm. Selecting half of the samples as standards, the precision and accuracy of propranolol concentrations were determined for the other half of the samples that were employed as a quality control data set. The resulting precision (±15%) and accuracy (±3%) were within acceptable limits. CONCLUSIONS Quantitation of adjacent mouse tissue sections of different organs and of various thicknesses by droplet-based surface sampling in comparison with bulk extraction of tissue punches showed that extraction efficiency was incomplete using the former method, and that it depended on the organ and tissue thickness. However, once extraction efficiency was determined and applied, the droplet-based approach provided satisfactory quantitation accuracy and precision for assay validations. Thus, once the extraction efficiency was calibrated for a given tissue type, tissue thickness and drug, the droplet-based approach provides a non-labour-intensive and high-throughput means to acquire spatially resolved quantitative analysis of multiple samples of the same type. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.
Collapse
Affiliation(s)
- Vilmos Kertesz
- Mass Spectrometry and Laser Spectroscopy Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37831-6131, USA
| | - Taylor M Weiskittel
- Mass Spectrometry and Laser Spectroscopy Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37831-6131, USA
- ORISE HERE Intern, University of Tennessee, Knoxville, TN, 37996, USA
| | - Marissa Vavrek
- Department of Pharmacokinetics, Pharmacodynamics, and Drug Metabolism, Merck Research Laboratories, West Point, PA, 19486, USA
| | - Carol Freddo
- Department of Pharmacokinetics, Pharmacodynamics, and Drug Metabolism, Merck Research Laboratories, West Point, PA, 19486, USA
| | - Gary J Van Berkel
- Mass Spectrometry and Laser Spectroscopy Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37831-6131, USA
| |
Collapse
|
9
|
Chen W, Wang L, Van Berkel GJ, Kertesz V, Gan J. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry. J Chromatogr A 2015; 1439:137-143. [PMID: 26589943 DOI: 10.1016/j.chroma.2015.10.093] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2015] [Revised: 10/07/2015] [Accepted: 10/25/2015] [Indexed: 12/01/2022]
Abstract
Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites were studied. Major organs (brain, lung, liver, kidney and muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed the same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. In addition, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement.
Collapse
Affiliation(s)
- Weiqi Chen
- Pharmaceutical Candidate Optimization, Bristol-Myers Squibb Research and Development, Princeton, NJ 08543, USA
| | - Lifei Wang
- Pharmaceutical Candidate Optimization, Bristol-Myers Squibb Research and Development, Princeton, NJ 08543, USA
| | - Gary J Van Berkel
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA
| | - Vilmos Kertesz
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA.
| | - Jinping Gan
- Pharmaceutical Candidate Optimization, Bristol-Myers Squibb Research and Development, Princeton, NJ 08543, USA.
| |
Collapse
|
10
|
Abstract
MS imaging has rapidly evolved over the last decade, finding roles in all aspects of pharmaceutical research and development. This article discusses possible methodological and technological future advancements and describes research areas where the technology can expand and continue to prove to be worthwhile tool for drug discovery and development.
Collapse
|
11
|
Liu X, Hummon AB. Mass spectrometry imaging of therapeutics from animal models to three-dimensional cell cultures. Anal Chem 2015; 87:9508-19. [PMID: 26084404 PMCID: PMC4766864 DOI: 10.1021/acs.analchem.5b00419] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Mass spectrometry imaging (MSI) is a powerful label-free technique for the investigation of the spatial distribution of molecules at complex surfaces and has been widely used in the pharmaceutical sciences to understand the distribution of different drugs and their metabolites in various biological samples, ranging from cell-based models to tissues. Here, we review the current applications of MSI for drug studies in animal models, followed by a discussion of the novel advances of MSI in three-dimensional (3D) cell cultures for accurate, efficient, and high-throughput analyses to evaluate therapeutics.
Collapse
Affiliation(s)
- Xin Liu
- Department of Chemistry and Biochemistry, Harper Cancer Research Institute, University of Notre Dame, 251 Nieuwland Science Hall, Notre Dame, IN 46556, USA
| | - Amanda B. Hummon
- Department of Chemistry and Biochemistry, Harper Cancer Research Institute, University of Notre Dame, 251 Nieuwland Science Hall, Notre Dame, IN 46556, USA
| |
Collapse
|
12
|
Barry JA, Groseclose MR, Robichaud G, Castellino S, Muddiman DC. Assessing drug and metabolite detection in liver tissue by UV-MALDI and IR-MALDESI mass spectrometry imaging coupled to FT-ICR MS. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2015; 377:448-155. [PMID: 26056514 PMCID: PMC4456684 DOI: 10.1016/j.ijms.2014.05.012] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Determining the distribution of a drug and its metabolites within tissue is a key facet of evaluating drug candidates. Drug distribution can have a significant implication in appraising drug efficacy and potential toxicity. The specificity and sensitivity of mass spectrometry imaging (MSI) make it a perfect complement to the analysis of drug distributions in tissue. The detection of lapatinib as well as several of its metabolites in liver tissue was determined by MSI using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) coupled to high resolving power Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers. IR-MALDESI required minimal sample preparation while maintaining high sensitivity. The effect of the electrospray solvent composition on IR-MALDESI MSI signal from tissue analysis was investigated and an empirical comparison of IR-MALDESI and UV-MALDI for MSI analysis is also presented.
Collapse
Affiliation(s)
- Jeremy A. Barry
- W.M. Keck FT-ICR Mass Spectrometry Laboratory, Department of Chemistry, North Carolina State University, Raleigh, North Carolina
| | - M. Reid Groseclose
- Department of Drug Metabolism& Pharmacokinetics, Platform Science & Technology, GlaxoSmithKline, Research Triangle Park, North Carolina
| | - Guillaume Robichaud
- W.M. Keck FT-ICR Mass Spectrometry Laboratory, Department of Chemistry, North Carolina State University, Raleigh, North Carolina
| | - Stephen Castellino
- Department of Drug Metabolism& Pharmacokinetics, Platform Science & Technology, GlaxoSmithKline, Research Triangle Park, North Carolina
| | - David C. Muddiman
- W.M. Keck FT-ICR Mass Spectrometry Laboratory, Department of Chemistry, North Carolina State University, Raleigh, North Carolina
- Author for Correspondence David C. Muddiman, Ph.D. W.M. Keck FT-ICR Mass Spectrometry Laboratory Department of Chemistry North Carolina State University Raleigh, North Carolina 27695 Phone: 919-513-0084 Fax: 919-513-7993
| |
Collapse
|
13
|
Almeida R, Berzina Z, Arnspang EC, Baumgart J, Vogt J, Nitsch R, Ejsing CS. Quantitative spatial analysis of the mouse brain lipidome by pressurized liquid extraction surface analysis. Anal Chem 2015; 87:1749-56. [PMID: 25548943 DOI: 10.1021/ac503627z] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Here we describe a novel surface sampling technique termed pressurized liquid extraction surface analysis (PLESA), which in combination with a dedicated high-resolution shotgun lipidomics routine enables both quantification and in-depth structural characterization of molecular lipid species extracted directly from tissue sections. PLESA uses a sealed and pressurized sampling probe that enables the use of chloroform-containing extraction solvents for efficient in situ lipid microextraction with a spatial resolution of 400 μm. Quantification of lipid species is achieved by the inclusion of internal lipid standards in the extraction solvent. The analysis of lipid microextracts by nanoelectrospray ionization provides long-lasting ion spray which in conjunction with a hybrid ion trap-orbitrap mass spectrometer enables identification and quantification of molecular lipid species using a method with successive polarity shifting, high-resolution Fourier transform mass spectrometry (FTMS), and fragmentation analysis. We benchmarked the performance of the PLESA approach for in-depth lipidome analysis by comparing it to conventional lipid extraction of excised tissue homogenates and by mapping the spatial distribution and molar abundance of 170 molecular lipid species across different anatomical mouse brain regions.
Collapse
Affiliation(s)
- Reinaldo Almeida
- VILLUM Center for Bioanalytical Sciences, Department of Biochemistry and Molecular Biology, University of Southern Denmark , Odense, Denmark
| | | | | | | | | | | | | |
Collapse
|
14
|
Nilsson A, Goodwin RJA, Shariatgorji M, Vallianatou T, Webborn PJH, Andrén PE. Mass Spectrometry Imaging in Drug Development. Anal Chem 2015; 87:1437-55. [DOI: 10.1021/ac504734s] [Citation(s) in RCA: 133] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Anna Nilsson
- Biomolecular
Imaging and Proteomics, National Center for Mass Spectrometry Imaging,
Department of Pharmaceutical Biosciences, Uppsala University, P.O. Box 591 BMC, 75124 Uppsala, Sweden
| | - Richard J. A. Goodwin
- Drug Safety & Metabolism, Innovative Medicines, AstraZeneca, Darwin Building 310, Cambridge Science Park, Milton Road, Cambridge, Cambridgeshire CB4 OWG, U.K
| | - Mohammadreza Shariatgorji
- Biomolecular
Imaging and Proteomics, National Center for Mass Spectrometry Imaging,
Department of Pharmaceutical Biosciences, Uppsala University, P.O. Box 591 BMC, 75124 Uppsala, Sweden
| | - Theodosia Vallianatou
- Biomolecular
Imaging and Proteomics, National Center for Mass Spectrometry Imaging,
Department of Pharmaceutical Biosciences, Uppsala University, P.O. Box 591 BMC, 75124 Uppsala, Sweden
| | - Peter J. H. Webborn
- Drug Safety & Metabolism, Innovative Medicines, AstraZeneca, Darwin Building 310, Cambridge Science Park, Milton Road, Cambridge, Cambridgeshire CB4 OWG, U.K
| | - Per E. Andrén
- Biomolecular
Imaging and Proteomics, National Center for Mass Spectrometry Imaging,
Department of Pharmaceutical Biosciences, Uppsala University, P.O. Box 591 BMC, 75124 Uppsala, Sweden
| |
Collapse
|
15
|
Eikel D, Henion JD. Liquid Extraction Surface Analysis Mass Spectrometry (LESA MS): Combining Liquid Extraction, Surface Profiling and Ambient Ionization Mass Spectrometry in One Novel Analysis Technique. AMBIENT IONIZATION MASS SPECTROMETRY 2014. [DOI: 10.1039/9781782628026-00482] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
In this chapter we give an overview of liquid extraction surface analysis mass spectrometry (LESA-MS), a novel analysis technique that combines liquid extraction from a surface of interest and ambient nanoelectrospray ionization combined with mass spectrometry to analyze compounds of interest. LESA MS was first described by van Berkel and Kertesz in 2009 and subsequently made commercially available by Advion Inc. by way of its TriVersa-NanoMate™ robotic nanoelectrospray ionization source. LESA was initially intended as a complementary analysis technique to MALDI imaging in pharmaceutical drug distribution and development; however, soon after the commercial availability of this technique, a broader use became apparent with applications ranging from biofilms on contact lenses, antibiotics expressed by bacteria cultured in agar, dried blood spot analysis, surface properties of aged plastics and aerosols from compactor material – to mention only a few. In this chapter, we will discuss selected applications and provide an outlook of LESA developments as they currently unfold, knowing full well that such a new technology will develop unexpectedly and in application areas not previously envisioned.
Collapse
|
16
|
Kertesz V, Weiskittel TM, Van Berkel GJ. An enhanced droplet-based liquid microjunction surface sampling system coupled with HPLC-ESI-MS/MS for spatially resolved analysis. Anal Bioanal Chem 2014; 407:2117-25. [PMID: 25377777 DOI: 10.1007/s00216-014-8287-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2014] [Revised: 10/16/2014] [Accepted: 10/20/2014] [Indexed: 11/25/2022]
Abstract
Droplet-based liquid microjunction surface sampling coupled with high-performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) for spatially resolved analysis provides the possibility of effective analysis of complex matrix samples and can provide a greater degree of chemical information from a single spot sample than is typically possible with a direct analysis of an extract. Described here is the setup and enhanced capabilities of a discrete droplet liquid microjunction surface sampling system employing a commercially available CTC PAL autosampler. The system enhancements include incorporation of a laser distance sensor enabling unattended analysis of samples and sample locations of dramatically disparate height as well as reliably dispensing just 0.5 μL of extraction solvent to make the liquid junction to the surface, wherein the extraction spot size was confined to an area about 0.7 mm in diameter; software modifications improving the spatial resolution of sampling spot selection from 1.0 to 0.1 mm; use of an open bed tray system to accommodate samples as large as whole-body rat thin tissue sections; and custom sample/solvent holders that shorten sampling time to approximately 1 min per sample. The merit of these new features was demonstrated by spatially resolved sampling, HPLC separation, and mass spectral detection of pharmaceuticals and metabolites from whole-body rat thin tissue sections and razor blade ("crude") cut mouse tissue.
Collapse
Affiliation(s)
- Vilmos Kertesz
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37831-6131, USA,
| | | | | |
Collapse
|
17
|
Sarsby J, Martin NJ, Lalor PF, Bunch J, Cooper HJ. Top-down and bottom-up identification of proteins by liquid extraction surface analysis mass spectrometry of healthy and diseased human liver tissue. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:1953-61. [PMID: 25183224 PMCID: PMC4197381 DOI: 10.1007/s13361-014-0967-z] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2014] [Revised: 07/10/2014] [Accepted: 07/15/2014] [Indexed: 05/18/2023]
Abstract
Liquid extraction surface analysis mass spectrometry (LESA MS) has the potential to become a useful tool in the spatially-resolved profiling of proteins in substrates. Here, the approach has been applied to the analysis of thin tissue sections from human liver. The aim was to determine whether LESA MS was a suitable approach for the detection of protein biomarkers of nonalcoholic liver disease (nonalcoholic steatohepatitis, NASH), with a view to the eventual development of LESA MS for imaging NASH pathology. Two approaches were considered. In the first, endogenous proteins were extracted from liver tissue sections by LESA, subjected to automated trypsin digestion, and the resulting peptide mixture was analyzed by liquid chromatography tandem mass spectrometry (LC-MS/MS) (bottom-up approach). In the second (top-down approach), endogenous proteins were extracted by LESA, and analyzed intact. Selected protein ions were subjected to collision-induced dissociation (CID) and/or electron transfer dissociation (ETD) mass spectrometry. The bottom-up approach resulted in the identification of over 500 proteins; however identification of key protein biomarkers, liver fatty acid binding protein (FABP1), and its variant (Thr→Ala, position 94), was unreliable and irreproducible. Top-down LESA MS analysis of healthy and diseased liver tissue revealed peaks corresponding to multiple (~15-25) proteins. MS/MS of four of these proteins identified them as FABP1, its variant, α-hemoglobin, and 10 kDa heat shock protein. The reliable identification of FABP1 and its variant by top-down LESA MS suggests that the approach may be suitable for imaging NASH pathology in sections from liver biopsies.
Collapse
Affiliation(s)
- Joscelyn Sarsby
- Physical Sciences of Imaging in the Biomedical Sciences Doctoral Training Centre, University of Birmingham, Edgbaston, Birmingham, B15 2TT UK
- School of Chemistry, University of Birmingham, Edgbaston, Birmingham, B15 2TT UK
- School of Biosciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT UK
| | - Nicholas J. Martin
- School of Biosciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT UK
| | - Patricia F. Lalor
- Centre for Liver Research and NIHR BRU, School of Immunity and Infection, University of Birmingham, Edgbaston, Birmingham, B15 2TT UK
| | - Josephine Bunch
- Physical Sciences of Imaging in the Biomedical Sciences Doctoral Training Centre, University of Birmingham, Edgbaston, Birmingham, B15 2TT UK
- School of Pharmacy, Boots Science Building, University Park, University of Nottingham, Nottingham, NG7 2RD UK
- Present Address: National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW UK
| | - Helen J. Cooper
- School of Biosciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT UK
| |
Collapse
|
18
|
Liquid microjunction surface sampling of acetaminophen, terfenadine and their metabolites in thin tissue sections. Bioanalysis 2014; 6:2599-606. [DOI: 10.4155/bio.14.130] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background: The aim of this work was to evaluate the analytical performance of a fully automated droplet-based surface-sampling system for determining the distribution of the drugs acetaminophen and terfenadine, and their metabolites, in rat thin tissue sections. Results: The rank order of acetaminophen concentration observed in tissues was stomach > small intestine > liver, while the concentrations of its glucuronide and sulfate metabolites were greatest in the liver and small intestine. Terfenadine was most concentrated in the liver and kidney, while its major metabolite, fexofenadine, was found in the liver and small intestine. Conclusion: The spatial distributions of both drugs and their respective metabolites observed in this work were consistent with previous studies using radiolabeled drugs.
Collapse
|
19
|
Swales JG, Tucker JW, Strittmatter N, Nilsson A, Cobice D, Clench MR, Mackay CL, Andren PE, Takáts Z, Webborn PJH, Goodwin RJA. Mass Spectrometry Imaging of Cassette-Dosed Drugs for Higher Throughput Pharmacokinetic and Biodistribution Analysis. Anal Chem 2014; 86:8473-80. [DOI: 10.1021/ac502217r] [Citation(s) in RCA: 75] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- John G. Swales
- Drug Safety and Metabolism, Innovative Medicines, AstraZeneca R&D, Alderley Park, Macclesfield, Cheshire SK10 4TG, U.K
- Biomedical Research
Centre, Sheffield Hallam University, Howard Street, Sheffield S1 1WB, U.K
| | - James W. Tucker
- Drug Safety and Metabolism, Innovative Medicines, AstraZeneca R&D, Alderley Park, Macclesfield, Cheshire SK10 4TG, U.K
| | - Nicole Strittmatter
- Department
of Surgery and Cancer, Sir Alexander Fleming Building, Imperial College, London SW7 2AZ, U.K
| | - Anna Nilsson
- Biomolecular Imaging
and Proteomics, National Center for Mass Spectrometry Imaging, Department of Pharmaceutical Biosciences, Uppsala University, Uppsala 751 05, Sweden
| | - Diego Cobice
- Department
of Surgery and Cancer, Sir Alexander Fleming Building, Imperial College, London SW7 2AZ, U.K
| | - Malcolm R. Clench
- Biomedical Research
Centre, Sheffield Hallam University, Howard Street, Sheffield S1 1WB, U.K
| | - C. Logan Mackay
- Department
of Surgery and Cancer, Sir Alexander Fleming Building, Imperial College, London SW7 2AZ, U.K
| | - Per E. Andren
- Biomolecular Imaging
and Proteomics, National Center for Mass Spectrometry Imaging, Department of Pharmaceutical Biosciences, Uppsala University, Uppsala 751 05, Sweden
| | - Zoltán Takáts
- Department
of Surgery and Cancer, Sir Alexander Fleming Building, Imperial College, London SW7 2AZ, U.K
| | - Peter J. H. Webborn
- Drug Safety and Metabolism, Innovative Medicines, AstraZeneca R&D, Alderley Park, Macclesfield, Cheshire SK10 4TG, U.K
| | - Richard J. A. Goodwin
- Drug Safety and Metabolism, Innovative Medicines, AstraZeneca R&D, Alderley Park, Macclesfield, Cheshire SK10 4TG, U.K
| |
Collapse
|
20
|
Tomlinson L, Fuchser J, Fütterer A, Baumert M, Hassall DG, West A, Marshall PS. Using a single, high mass resolution mass spectrometry platform to investigate ion suppression effects observed during tissue imaging. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2014; 28:995-1003. [PMID: 24677520 DOI: 10.1002/rcm.6869] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2013] [Revised: 02/12/2014] [Accepted: 02/13/2014] [Indexed: 05/24/2023]
Abstract
RATIONALE The signal intensity of a given molecule across a tissue section when measured using mass spectrometry imaging (MSI) is prone to changes caused by the molecular heterogeneity across the surface of the tissue. Here we propose a strategy to investigate these effects using electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) on a single high-resolution mass spectrometry (HRMS) platform. METHODS A rat was administered with a single inhaled dose of a compound and sacrificed 1 h after dosing. Sections were prepared from the excised frozen lung and analysed using MALDI, liquid extraction surface analysis (LESA) nano-ESI-MS and nano-ESI liquid chromatography (LC)/MS. The ESI and MALDI ion sources were mounted either side of the ion transfer system of the same Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. RESULTS MALDI MSI clearly demonstrated widespread distribution of the dosed molecule throughout the lung, with the exception of a non-lung section of tissue on the same sample surface. Comparison of the lipid signals across the sample indicated a change in signal between the lung and the adipose tissue present on the same section. Use of ESI and MALDI, with and without an internal standard, supported the evaluation of changes in the signal of the dosed molecule across the tissue section. CONCLUSIONS The results demonstrate the successful application of a dual ion source HRMS system to the systematic evaluation of data from MALDI MSI, used to determine the distribution of an inhaled drug in the lung. The system discussed is of great utility in investigating the effects of ion suppression and evaluating the quantitative and qualitative nature of the MSI data.
Collapse
Affiliation(s)
- Laura Tomlinson
- Platform Technology and Science (PTS), Chemical Sciences, UK, GlaxoSmithKline (GSK), Medicines Research Centre, Gunnels Wood Road, Stevenage, SG1 2NY, UK
| | | | | | | | | | | | | |
Collapse
|
21
|
Automated liquid microjunction surface sampling-HPLC-MS/MS analysis of drugs and metabolites in whole-body thin tissue sections. Bioanalysis 2014; 5:819-26. [PMID: 23534426 DOI: 10.4155/bio.13.42] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND The aim of this work was to develop a fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled with HPLC-MS/MS detection. RESULTS Discrete spots selected for droplet-based sampling and automated sample queue generation, for both the autosampler and MS, were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling positions and HPLC-MS information to generate heat maps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol-dosed rats. CONCLUSION The spatial distributions of both the drug and its hydroxypropranolol glucuronide metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.
Collapse
|
22
|
Ferreira CR, Wu L, Vogt FG, Bornancini ER, Cooks RG. Fiducial Markers for Distribution of Drug and Excipient on Tablet Surfaces by Multimodal Desorption Electrospray Ionization–Mass Spectrometry (DESI–MS) Imaging. ANAL LETT 2013. [DOI: 10.1080/00032719.2013.832269] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
23
|
Lietz CB, Gemperline E, Li L. Qualitative and quantitative mass spectrometry imaging of drugs and metabolites. Adv Drug Deliv Rev 2013; 65:1074-85. [PMID: 23603211 DOI: 10.1016/j.addr.2013.04.009] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2012] [Revised: 03/27/2013] [Accepted: 04/09/2013] [Indexed: 12/26/2022]
Abstract
Mass spectrometric imaging (MSI) has rapidly increased its presence in the pharmaceutical sciences. While quantitative whole-body autoradiography and microautoradiography are the traditional techniques for molecular imaging of drug delivery and metabolism, MSI provides advantageous specificity that can distinguish the parent drug from metabolites and modified endogenous molecules. This review begins with the fundamentals of MSI sample preparation/ionization, and then moves on to both qualitative and quantitative applications with special emphasis on drug discovery and delivery. Cutting-edge investigations on sub-cellular imaging and endogenous signaling peptides are also highlighted, followed by perspectives on emerging technology and the path for MSI to become a routine analysis technique.
Collapse
|
24
|
Van Berkel GJ, Kertesz V. Continuous-flow liquid microjunction surface sampling probe connected on-line with high-performance liquid chromatography/mass spectrometry for spatially resolved analysis of small molecules and proteins. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2013; 27:1329-34. [PMID: 23681810 DOI: 10.1002/rcm.6580] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2013] [Revised: 03/13/2013] [Accepted: 03/25/2013] [Indexed: 05/05/2023]
Abstract
RATIONALE A continuous-flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by mass spectrometry. Demonstrated here is the on-line coupling of such a probe with high-performance liquid chromatography/mass spectrometry (HPLC/MS) enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. METHODS A continuous-flow liquid microjunction surface sampling probe was connected to a six-port, two-position valve for extract collection and injection to an HPLC column. A QTRAP® 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V™ ion source operated in positive electrospray ionization (ESI) mode was used for all experiments. The system operation was tested with the extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues, caffeine from a coffee bean, cocaine from paper currency, and proteins from dried sheep blood spots on paper. RESULTS Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin α and β chains. CONCLUSIONS Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous-flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection.
Collapse
Affiliation(s)
- Gary J Van Berkel
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6131, USA.
| | | |
Collapse
|
25
|
Quanico J, Franck J, Dauly C, Strupat K, Dupuy J, Day R, Salzet M, Fournier I, Wisztorski M. Development of liquid microjunction extraction strategy for improving protein identification from tissue sections. J Proteomics 2013; 79:200-18. [DOI: 10.1016/j.jprot.2012.11.025] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2012] [Revised: 11/20/2012] [Accepted: 11/30/2012] [Indexed: 12/22/2022]
|
26
|
Monge ME, Harris GA, Dwivedi P, Fernández FM. Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization. Chem Rev 2013; 113:2269-308. [DOI: 10.1021/cr300309q] [Citation(s) in RCA: 404] [Impact Index Per Article: 36.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- María Eugenia Monge
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| | - Glenn A. Harris
- Department
of Biochemistry and
the Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Prabha Dwivedi
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| | - Facundo M. Fernández
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| |
Collapse
|
27
|
Parson WB, Koeniger SL, Johnson RW, Erickson J, Tian Y, Stedman C, Schwartz A, Tarcsa E, Cole R, Van Berkel GJ. Analysis of chloroquine and metabolites directly from whole-body animal tissue sections by liquid extraction surface analysis (LESA) and tandem mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2012; 47:1420-8. [PMID: 23147817 DOI: 10.1002/jms.3068] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The rapid and direct analysis of the amount and spatial distribution of exogenous chloroquine (CHQ) and CHQ metabolites from tissue sections by liquid extraction surface sampling analysis coupled with tandem mass spectrometry (LESA-MS/MS) was demonstrated. LESA-MS/MS results compared well with previously published CHQ quantification data collected by organ excision, extraction and fluorescent detection. The ability to directly sample and analyze spatially resolved exogenous molecules from tissue sections with minimal sample preparation and analytical method development has the potential to facilitate the assessment of target tissue penetration of pharmaceutical compounds, to establish pharmacokinetic/pharmacodynamic relationships, and to complement established pharmacokinetic methods used in the drug discovery process during tissue distribution assessment.
Collapse
Affiliation(s)
- Whitney B Parson
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Donegan M, Browning M. A REVIEW RECENT DEVELOPMENTS IN SAMPLE IONIZATION INTERFACES USED IN MASS SPECTROMETRY. J LIQ CHROMATOGR R T 2012. [DOI: 10.1080/10826076.2012.714595] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
| | - Marc Browning
- a Bristol-Myers Squibb , Wallingford , Connecticut , USA
| |
Collapse
|
29
|
Mass spectrometry imaging is moving toward drug protein co-localization. Trends Biotechnol 2012; 30:466-74. [DOI: 10.1016/j.tibtech.2012.05.006] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2012] [Revised: 05/23/2012] [Accepted: 05/24/2012] [Indexed: 12/20/2022]
|
30
|
Prideaux B, Stoeckli M. Mass spectrometry imaging for drug distribution studies. J Proteomics 2012; 75:4999-5013. [DOI: 10.1016/j.jprot.2012.07.028] [Citation(s) in RCA: 224] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2012] [Revised: 07/15/2012] [Accepted: 07/16/2012] [Indexed: 01/13/2023]
|
31
|
Abstract
Imaging MS (IMS) is generating tremendous interest in scientific communities because of its unparalleled capabilities to provide chemical analysis of intact tissue. Advances in analytical chemistry and MS are providing new insights into chemical and biological processes. This review will discuss various IMS platforms and their applications in biomedical and pharmaceutical research.
Collapse
|