1
|
VilasBoas-Ribeiro I, Sumser K, Nouwens S, Feddersen T, Heemels W, van Rhoon GC, Paulides MM. Adapting Temperature Predictions to MR Imaging in Treatment Position to Improve Simulation-Guided Hyperthermia for Cervical Cancer. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2023; 5:99-106. [PMID: 38445240 PMCID: PMC10914156 DOI: 10.1109/ojemb.2023.3321990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 04/13/2023] [Accepted: 09/21/2023] [Indexed: 03/07/2024] Open
Abstract
Hyperthermia treatment consists of elevating the temperature of the tumor to increase the effectiveness of radiotherapy and chemotherapy. Hyperthermia treatment planning (HTP) is an important tool to optimize treatment quality using pre-treatment temperature predictions. The accuracy of these predictions depends on modeling uncertainties such as tissue properties and positioning. In this study, we evaluated if HTP accuracy improves when the patient is imaged inside the applicator at the start of treatment. Because perfusion is a major uncertainty source, the importance of accurate treatment position and anatomy was evaluated using different perfusion values. Volunteers were scanned using MR imaging without ("planning setup") and with the MR-compatible hyperthermia device ("treatment setup"). Temperature-based quality indicators were used to assess the differences between the standard, apparent and the optimized hyperthermia dose. We conclude that pre-treatment imaging can improve HTP predictions accuracy but also, that tissue perfusion modelling is crucial if temperature-based optimization is applied.
Collapse
Affiliation(s)
- Iva VilasBoas-Ribeiro
- Department of Radiotherapy, Erasmus MC Cancer InstituteUniversity Medical Center Rotterdam3015GDRotterdamThe Netherlands
| | - Kemal Sumser
- Care and Cure research lab (EM-4C&C) of the Electromagnetics Group, Department of Electrical EngineeringEindhoven University of Technology5600 MBEindhovenThe Netherlands
| | - Sven Nouwens
- Control System Technology Group, Department of Mechanical EngineeringEindhoven University of Technology5600 MBEindhovenThe Netherlands
| | - Theresa Feddersen
- Department of Radiology & Nuclear Medicine, Erasmus MCUniversity Medical Center Rotterdam3015GDRotterdamThe Netherlands
| | - W.P.M.H. Heemels
- Control System Technology Group, Department of Mechanical EngineeringEindhoven University of Technology5600 MBEindhovenThe Netherlands
| | - Gerard C. van Rhoon
- Department of Radiotherapy, Erasmus MC Cancer InstituteUniversity Medical Center Rotterdam3015GDRotterdamThe Netherlands
- Department of Applied Radiation and Isotopes, Reactor Institute DelftDelft University of Technology2629JBDelftThe Netherlands
| | - Margarethus M. Paulides
- Care and Cure research lab (EM-4C&C) of the Electromagnetics Group, Department of Electrical EngineeringEindhoven University of Technology5600 MBEindhovenThe Netherlands
| |
Collapse
|
2
|
Drizdal T, van Rhoon GC, Fiser O, Vrba D, van Holthe N, Vrba J, Paulides MM. Assessment of the thermal tissue models for the head and neck hyperthermia treatment planning. J Therm Biol 2023; 115:103625. [PMID: 37429086 DOI: 10.1016/j.jtherbio.2023.103625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 06/09/2023] [Accepted: 06/09/2023] [Indexed: 07/12/2023]
Abstract
PURPOSE To compare different thermal tissue models for head and neck hyperthermia treatment planning, and to assess the results using predicted and measured applied power data from clinical treatments. METHODS Three commonly used temperature models from literature were analysed: "constant baseline", "constant thermal stress" and "temperature dependent". Power and phase data of 93 treatments of 20 head and neck patients treated with the HYPERcollar3D applicator were used. The impact on predicted median temperature T50 inside the target region was analysed with maximum allowed temperature of 44 °C in healthy tissue. The robustness of predicted T50 for the three models against the influence of blood perfusion, thermal conductivity and the assumed hotspot temperature level was analysed. RESULTS We found an average predicted T50 of 41.0 ± 1.3 °C (constant baseline model), 39.9 ± 1.1 °C (constant thermal stress model) and 41.7 ± 1.1 °C (temperature dependent model). The constant thermal stress model resulted in the best agreement between the predicted power (P = 132.7 ± 45.9 W) and the average power measured during the hyperthermia treatments (P = 129.1 ± 83.0 W). CONCLUSION The temperature dependent model predicts an unrealistically high T50. The power values for the constant thermal stress model, after scaling simulated maximum temperatures to 44 °C, matched best to the average measured powers. We consider this model to be the most appropriate for temperature predictions using the HYPERcollar3D applicator, however further studies are necessary for developing of robust temperature model for tissues during heat stress.
Collapse
Affiliation(s)
- Tomas Drizdal
- Hyperthermia Unit, Dept. of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein, 3015 GD, Rotterdam, Rotterdam, the Netherlands; Dept. of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, 272 01, Kladno, Czech Republic.
| | - Gerard C van Rhoon
- Hyperthermia Unit, Dept. of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein, 3015 GD, Rotterdam, Rotterdam, the Netherlands
| | - Ondrej Fiser
- Dept. of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, 272 01, Kladno, Czech Republic
| | - David Vrba
- Dept. of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, 272 01, Kladno, Czech Republic
| | - Netteke van Holthe
- Hyperthermia Unit, Dept. of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein, 3015 GD, Rotterdam, Rotterdam, the Netherlands
| | - Jan Vrba
- Dept. of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, 272 01, Kladno, Czech Republic
| | - Margarethus M Paulides
- Hyperthermia Unit, Dept. of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein, 3015 GD, Rotterdam, Rotterdam, the Netherlands; Dept. of Electrical Engineering, Eindhoven University of Technology, De Rondom 70, 5612 AP, Eindhoven, the Netherlands
| |
Collapse
|
3
|
Saha N, Kuehne A, Millward JM, Eigentler TW, Starke L, Waiczies S, Niendorf T. Advanced Radio Frequency Applicators for Thermal Magnetic Resonance Theranostics of Brain Tumors. Cancers (Basel) 2023; 15:cancers15082303. [PMID: 37190232 DOI: 10.3390/cancers15082303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/09/2023] [Accepted: 04/11/2023] [Indexed: 05/17/2023] Open
Abstract
Thermal Magnetic Resonance (ThermalMR) is a theranostic concept that combines diagnostic magnetic resonance imaging (MRI) with targeted thermal therapy in the hyperthermia (HT) range using a radiofrequency (RF) applicator in an integrated system. ThermalMR adds a therapeutic dimension to a diagnostic MRI device. Focused, targeted RF heating of deep-seated brain tumors, accurate non-invasive temperature monitoring and high-resolution MRI are specific requirements of ThermalMR that can be addressed with novel concepts in RF applicator design. This work examines hybrid RF applicator arrays combining loop and self-grounded bow-tie (SGBT) dipole antennas for ThermalMR of brain tumors, at magnetic field strengths of 7.0 T, 9.4 T and 10.5 T. These high-density RF arrays improve the feasible transmission channel count, and provide additional degrees of freedom for RF shimming not afforded by using dipole antennas only, for superior thermal therapy and MRI diagnostics. These improvements are especially relevant for ThermalMR theranostics of deep-seated brain tumors because of the small surface area of the head. ThermalMR RF applicators with the hybrid loop+SGBT dipole design outperformed applicators using dipole-only and loop-only designs, with superior MRI performance and targeted RF heating. Array variants with a horse-shoe configuration covering an arc (270°) around the head avoiding the eyes performed better than designs with 360° coverage, with a 1.3 °C higher temperature rise inside the tumor while sparing healthy tissue. Our EMF and temperature simulations performed on a virtual patient with a clinically realistic intracranial tumor provide a technical foundation for implementation of advanced RF applicators tailored for ThermalMR theranostics of brain tumors.
Collapse
Affiliation(s)
- Nandita Saha
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
- Charité-Universitätsmedizin Berlin, Experimental and Clinical Research Center (ECRC), A Joint Cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine in the Helmholtz Association, 13125 Berlin, Germany
| | - Andre Kuehne
- MRI.TOOLS GmbH, 13125 Berlin, Germany
- Brightmind.AI GmbH, 1010 Vienna, Austria
| | - Jason M Millward
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
- Charité-Universitätsmedizin Berlin, Experimental and Clinical Research Center (ECRC), A Joint Cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine in the Helmholtz Association, 13125 Berlin, Germany
| | - Thomas Wilhelm Eigentler
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
| | - Ludger Starke
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
- Hasso Plattner Institute for Digital Engineering, University of Potsdam, 14482 Potsdam, Germany
| | - Sonia Waiczies
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
- Charité-Universitätsmedizin Berlin, Experimental and Clinical Research Center (ECRC), A Joint Cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine in the Helmholtz Association, 13125 Berlin, Germany
| | - Thoralf Niendorf
- Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), 13125 Berlin, Germany
- Charité-Universitätsmedizin Berlin, Experimental and Clinical Research Center (ECRC), A Joint Cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine in the Helmholtz Association, 13125 Berlin, Germany
- MRI.TOOLS GmbH, 13125 Berlin, Germany
| |
Collapse
|
4
|
Bevacqua MT, Gaffoglio R, Bellizzi GG, Righero M, Giordanengo G, Crocco L, Vecchi G, Isernia T. Field and Temperature Shaping for Microwave Hyperthermia: Recent Treatment Planning Tools to Enhance SAR-Based Procedures. Cancers (Basel) 2023; 15:cancers15051560. [PMID: 36900351 PMCID: PMC10000666 DOI: 10.3390/cancers15051560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 02/13/2023] [Accepted: 02/27/2023] [Indexed: 03/06/2023] Open
Abstract
The aim of the article is to provide a summary of the work carried out in the framework of a research project funded by the Italian Ministry of Research. The main goal of the activity was to introduce multiple tools for reliable, affordable, and high-performance microwave hyperthermia for cancer therapy. The proposed methodologies and approaches target microwave diagnostics, accurate in vivo electromagnetic parameters estimation, and improvement in treatment planning using a single device. This article provides an overview of the proposed and tested techniques and shows their complementarity and interconnection. To highlight the approach, we also present a novel combination of specific absorption rate optimization via convex programming with a temperature-based refinement method implemented to mitigate the effect of thermal boundary conditions on the final temperature map. To this purpose, numerical tests were carried out for both simple and anatomically detailed 3D scenarios for the head and neck region. These preliminary results show the potential of the combined technique and improvements in the temperature coverage of the tumor target with respect to the case wherein no refinement is adopted.
Collapse
Affiliation(s)
- Martina T. Bevacqua
- Department of Information Engineering, Infrastructures and Sustainable Energy, Università Mediterranea di Reggio Calabria, Via Graziella, 89124 Reggio di Calabria, Italy
- Consorzio Nazionale Interuniversitario per le Telecomunicazioni (CNIT), Consorzio Nazionale Interuniversitario per le Telecomunicazioni, Viale G.P. Usberti, 181/A Pal.3, 43124 Parma, Italy
| | - Rossella Gaffoglio
- Advanced Computing, Photonics & Electromagnetics (CPE), Fondazione LINKS, 10138 Turin, Italy
| | - Gennaro G. Bellizzi
- Department of Information Engineering, Infrastructures and Sustainable Energy, Università Mediterranea di Reggio Calabria, Via Graziella, 89124 Reggio di Calabria, Italy
- Correspondence: (G.G.B.); (T.I.)
| | - Marco Righero
- Advanced Computing, Photonics & Electromagnetics (CPE), Fondazione LINKS, 10138 Turin, Italy
| | - Giorgio Giordanengo
- Advanced Computing, Photonics & Electromagnetics (CPE), Fondazione LINKS, 10138 Turin, Italy
| | - Lorenzo Crocco
- National Research Council of Italy (CNR), Istituto per il Rilevamento Elettromagnetico dell’ Ambiente, CNR-IREA, Via Diocleziano 308, 80100 Napoli, Italy
| | - Giuseppe Vecchi
- Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Turin, Italy
| | - Tommaso Isernia
- Department of Information Engineering, Infrastructures and Sustainable Energy, Università Mediterranea di Reggio Calabria, Via Graziella, 89124 Reggio di Calabria, Italy
- Consorzio Nazionale Interuniversitario per le Telecomunicazioni (CNIT), Consorzio Nazionale Interuniversitario per le Telecomunicazioni, Viale G.P. Usberti, 181/A Pal.3, 43124 Parma, Italy
- National Research Council of Italy (CNR), Istituto per il Rilevamento Elettromagnetico dell’ Ambiente, CNR-IREA, Via Diocleziano 308, 80100 Napoli, Italy
- Correspondence: (G.G.B.); (T.I.)
| |
Collapse
|
5
|
Zanoli M, Dobšíček Trefná H. The hot-to-cold spot quotient for SAR-based treatment planning in deep microwave hyperthermia. Int J Hyperthermia 2022; 39:1421-1439. [DOI: 10.1080/02656736.2022.2136411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
- Massimiliano Zanoli
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Hana Dobšíček Trefná
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| |
Collapse
|
6
|
Androulakis I, Sumser K, Machielse MND, Koppert L, Jager A, Nout R, Franckena M, van Rhoon GC, Curto S. Patient-derived breast model repository, a tool for hyperthermia treatment planning and applicator design. Int J Hyperthermia 2022; 39:1213-1221. [DOI: 10.1080/02656736.2022.2121862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022] Open
Affiliation(s)
- Ioannis Androulakis
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| | - Kemal Sumser
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| | - Melanie N. D. Machielse
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| | - Linetta Koppert
- Department of Surgical Oncology, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| | - Agnes Jager
- Department of Medical Oncology, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| | - Remi Nout
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| | - Martine Franckena
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| | - Gerard C. van Rhoon
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
- Department of Radiation Science and Technology, Delft University of Technology, Delft, The Netherlands
| | - Sergio Curto
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
7
|
VilasBoas-Ribeiro I, Franckena M, van Rhoon GC, Hernández-Tamames JA, Paulides MM. Using MRI to measure position and anatomy changes and assess their impact on the accuracy of hyperthermia treatment planning for cervical cancer. Int J Hyperthermia 2022; 40:2151648. [PMID: 36535922 DOI: 10.1080/02656736.2022.2151648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
PURPOSE We studied the differences between planning and treatment position, their impact on the accuracy of hyperthermia treatment planning (HTP) predictions, and the relevance of including true treatment anatomy and position in HTP based on magnetic resonance (MR) images. MATERIALS AND METHODS All volunteers were scanned with an MR-compatible hyperthermia device, including a filled waterbolus, to replicate the treatment setup. In the planning setup, the volunteers were scanned without the device to reproduce the imaging in the current HTP. First, we used rigid registration to investigate the patient position displacements between the planning and treatment setup. Second, we performed HTP for the planning anatomy at both positions and the treatment mimicking anatomy to study the effects of positioning and anatomy on the quality of the simulated hyperthermia treatment. Treatment quality was evaluated using SAR-based parameters. RESULTS We found an average displacement of 2 cm between planning and treatment positions. These displacements caused average absolute differences of ∼12% for TC25 and 10.4%-15.9% in THQ. Furthermore, we found that including the accurate treatment position and anatomy in treatment planning led to an improvement of 2% in TC25 and 4.6%-10.6% in THQ. CONCLUSIONS This study showed that precise patient position and anatomy are relevant since these affect the accuracy of HTP predictions. The major part of improved accuracy is related to implementing the correct position of the patient in the applicator. Hence, our study shows a clear incentive to accurately match the patient position in HTP with the actual treatment.
Collapse
Affiliation(s)
- Iva VilasBoas-Ribeiro
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Martine Franckena
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Gerard C van Rhoon
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands.,Department of Applied Radiation and Isotopes, Reactor Institute Delft, Delft University of Technology, Delft, The Netherlands
| | - Juan A Hernández-Tamames
- Department of Radiology and Nuclear Medicine, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Margarethus M Paulides
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands.,Care and Cure research lab (EM-4C&C) of the Electromagnetics Group, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
8
|
Drizdal T, Paulides MM, Sumser K, Vrba D, Malena L, Vrba J, Fiser O, van Rhoon GC. Application of photogrammetry reconstruction for hyperthermia quality control measurements. Phys Med 2022; 101:87-94. [PMID: 35987024 DOI: 10.1016/j.ejmp.2022.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Accepted: 08/04/2022] [Indexed: 11/29/2022] Open
Abstract
PURPOSE Hyperthermia is a cancer treatment in which the target region is heated to temperatures of 40-44 °C usually applying external electromagnetic field sources. The behavior of the hyperthermia applicators (antennas) in clinical practice should be periodically checked with phantom experiments to verify the applicator's performance over time. The purpose of this study was to investigate the application of photogrammetry reconstructions of 3D applicator position in these quality control procedure measurements. METHODS Photogrammetry reconstruction was applied at superficial hyperthermia scenario using the Lucite cone applicator (LCA) and phased-array heating in the head and neck region using the HYPERcollar3D. Wire-frame models of the entire measurement setups were created from multiple-view images and used for recreation of the setup inside 3D electromagnetic field simulation software. We evaluated applicator relation (Ra) between measured and simulated absolute specific absorption rate (SAR) for manually created and photogrammetry reconstructed simulation setups. RESULTS We found a displacement of 7.9 mm for the LCA and 8.2 mm for the HYPERcollar3D setups when comparing manually created and photogrammetry reconstructed applicator models placements. Ra improved from 1.24 to 1.18 for the LCA and from 1.17 to 1.07 for the HYPERcollar3D when using photogrammetry reconstructed simulation setups. CONCLUSION Photogrammetry reconstruction technique holds promise to improve measurement setup reconstruction and agreement between measured and simulated absolute SAR.
Collapse
Affiliation(s)
- Tomas Drizdal
- Dept. of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, nam. Sitna 3105, 272 01 Kladno, Czech Republic; Hyperthermia Unit, Dept. of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein 40, 3015 GD Rotterdam, the Netherlands.
| | - Margarethus M Paulides
- Hyperthermia Unit, Dept. of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein 40, 3015 GD Rotterdam, the Netherlands; Dept. of Electrical Engineering, Eindhoven University of Technology, De Rondom 70, 5612 AP Eindhoven, the Netherlands
| | - Kemal Sumser
- Hyperthermia Unit, Dept. of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein 40, 3015 GD Rotterdam, the Netherlands
| | - David Vrba
- Dept. of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, nam. Sitna 3105, 272 01 Kladno, Czech Republic
| | - Lukas Malena
- Dept. of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, nam. Sitna 3105, 272 01 Kladno, Czech Republic
| | - Jan Vrba
- Dept. of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, nam. Sitna 3105, 272 01 Kladno, Czech Republic
| | - Ondrej Fiser
- Dept. of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, nam. Sitna 3105, 272 01 Kladno, Czech Republic
| | - Gerard C van Rhoon
- Hyperthermia Unit, Dept. of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein 40, 3015 GD Rotterdam, the Netherlands
| |
Collapse
|
9
|
VilasBoas-Ribeiro I, Nouwens SAN, Curto S, Jager BD, Franckena M, van Rhoon GC, Heemels WPMH, Paulides MM. POD-Kalman filtering for improving noninvasive 3D temperature monitoring in MR-guided hyperthermia. Med Phys 2022; 49:4955-4970. [PMID: 35717578 PMCID: PMC9545729 DOI: 10.1002/mp.15811] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 05/26/2022] [Accepted: 06/02/2022] [Indexed: 12/21/2022] Open
Abstract
Background During resonance frequency (RF) hyperthermia treatment, the temperature of the tumor tissue is elevated to the range of 39–44°C. Accurate temperature monitoring is essential to guide treatments and ensure precise heat delivery and treatment quality. Magnetic resonance (MR) thermometry is currently the only clinical method to measure temperature noninvasively in a volume during treatment. However, several studies have shown that this approach is not always sufficiently accurate for thermal dosimetry in areas with motion, such as the pelvic region. Model‐based temperature estimation is a promising approach to correct and supplement 3D online temperature estimation in regions where MR thermometry is unreliable or cannot be measured. However, complete 3D temperature modeling of the pelvic region is too complex for online usage. Purpose This study aimed to evaluate the use of proper orthogonal decomposition (POD) model reduction combined with Kalman filtering to improve temperature estimation using MR thermometry. Furthermore, we assessed the benefit of this method using data from hyperthermia treatment where there were limited and unreliable MR thermometry measurements. Methods The performance of POD–Kalman filtering was evaluated in several heating experiments and for data from patients treated for locally advanced cervical cancer. For each method, we evaluated the mean absolute error (MAE) concerning the temperature measurements acquired by the thermal probes, and we assessed the reproducibility and consistency using the standard deviation of error (SDE). Furthermore, three patient groups were defined according to susceptibility artifacts caused by the level of intestinal gas motion to assess if the POD–Kalman filtering could compensate for missing and unreliable MR thermometry measurements. Results First, we showed that this method is beneficial and reproducible in phantom experiments. Second, we demonstrated that the combined method improved the match between temperature prediction and temperature acquired by intraluminal thermometry for patients treated for locally advanced cervical cancer. Considering all patients, the POD–Kalman filter improved MAE by 43% (filtered MR thermometry = 1.29°C, POD–Kalman filtered temperature = 0.74°C). Moreover, the SDE was improved by 47% (filtered MR thermometry = 1.16°C, POD–Kalman filtered temperature = 0.61°C). Specifically, the POD–Kalman filter reduced the MAE by approximately 60% in patients whose MR thermometry was unreliable because of the great amount of susceptibilities caused by the high level of intestinal gas motion. Conclusions We showed that the POD–Kalman filter significantly improved the accuracy of temperature monitoring compared to MR thermometry in heating experiments and hyperthermia treatments. The results demonstrated that POD–Kalman filtering can improve thermal dosimetry during RF hyperthermia treatment, especially when MR thermometry is inaccurate.
Collapse
Affiliation(s)
- Iva VilasBoas-Ribeiro
- Department of Radiotherapy, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Sven A N Nouwens
- Control System Technology Group, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Sergio Curto
- Department of Radiotherapy, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Bram de Jager
- Control System Technology Group, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Martine Franckena
- Department of Radiotherapy, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Gerard C van Rhoon
- Department of Radiotherapy, Erasmus MC, University Medical Center, Rotterdam, The Netherlands.,Department of Radiation Science and Technology, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands
| | - W P M H Heemels
- Control System Technology Group, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Margarethus M Paulides
- Department of Radiotherapy, Erasmus MC, University Medical Center, Rotterdam, The Netherlands.,Care and Cure Research Lab (EM-4C&C) of the Electromagnetics Group, Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
10
|
Simultaneous ThermoBrachytherapy: Electromagnetic Simulation Methods for Fast and Accurate Adaptive Treatment Planning. SENSORS 2022; 22:s22041328. [PMID: 35214230 PMCID: PMC8963063 DOI: 10.3390/s22041328] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Revised: 02/04/2022] [Accepted: 02/08/2022] [Indexed: 12/18/2022]
Abstract
The combination of interstitial hyperthermia treatment (IHT) with high dose rate brachytherapy (HDR-BT) can improve clinical outcomes since it highly enhances the efficiency of cell kill, especially when applied simultaneously. Therefore, we have developed the ThermoBrachy applicators. To effectively apply optimal targeted IHT, treatment planning is considered essential. However, treatment planning in IHT is rarely applied as it is regarded as difficult to accurately calculate the deposited energy in the tissue in a short enough time for clinical practice. In this study, we investigated various time-efficient methods for fast computation of the electromagnetic (EM) energy deposition resulting from the ThermoBrachy applicators. Initially, we investigated the use of an electro-quasistatic solver. Next, we extended our investigation to the application of geometric simplifications. Furthermore, we investigated the validity of the superpositioning principle, which can enable adaptive treatment plan optimization without the need for continuous recomputation of the EM field. Finally, we evaluated the accuracy of the methods by comparing them to the golden standard Finite-Difference Time-Domain calculation method using gamma-index analysis. The simplifications considerably reduced the computation time needed, improving from >12 h to a few seconds. All investigated methods showed excellent agreement with the golden standard by showing a >99% passing rate with 1%/0.5 mm Dose Difference and Distance-to-Agreement criteria. These results allow the proposed electromagnetic simulation method to be used for fast and accurate adaptive treatment planning.
Collapse
|
11
|
Kok HP, Crezee J. Adapt2Heat: treatment planning-assisted locoregional hyperthermia by on-line visualization, optimization and re-optimization of SAR and temperature distributions. Int J Hyperthermia 2022; 39:265-277. [PMID: 35109742 DOI: 10.1080/02656736.2022.2032845] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
BACKGROUND Hyperthermia treatment planning is increasingly used in clinical applications and recommended in quality assurance guidelines. Assistance in phase-amplitude steering during treatment requires dedicated software for on-line visualization of SAR/temperature distributions and fast re-optimization in response to hot spots. As such software tools are not yet commercially available, we developed Adapt2Heat for on-line adaptive hyperthermia treatment planning and illustrate possible application by different relevant real patient examples. METHODS Adapt2Heat was developed as a separate module of the treatment planning software Plan2Heat. Adapt2Heat runs on a Linux operating system and was developed in C++, using the open source Qt, Qwt and VTK libraries. A graphical user interface allows interactive and flexible on-line use of hyperthermia treatment planning. Predicted SAR/temperature distributions and statistics for selected phase-amplitude settings can be visualized instantly and settings can be re-optimized manually or automatically in response to hot spots. RESULTS Pretreatment planning E-Field, SAR and temperature calculations are performed with Plan2Heat and imported in Adapt2Heat. Examples show that Adapt2Heat can be helpful in assisting with phase-amplitude steering, e.g., by suppressing indicated hot spots. The effects of phase-amplitude adjustments on the tumor and potential hot spot locations are comprehensively visualized, allowing intuitive and flexible assistance by treatment planning during locoregional hyperthermia treatments. CONCLUSION Adapt2Heat provides an intuitive and flexible treatment planning tool for on-line treatment planning-assisted hyperthermia. Extensive features for visualization and (re-)optimization during treatment allow practical use in many locoregional hyperthermia applications. This type of tools are indispensable for enhancing the quality of hyperthermia treatment delivery.
Collapse
Affiliation(s)
- H Petra Kok
- Department Radiation Oncology, Cancer Center Amsterdam, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Johannes Crezee
- Department Radiation Oncology, Cancer Center Amsterdam, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
12
|
IJff M, Crezee J, Oei AL, Stalpers LJA, Westerveld H. The role of hyperthermia in the treatment of locally advanced cervical cancer: a comprehensive review. Int J Gynecol Cancer 2022; 32:288-296. [PMID: 35046082 PMCID: PMC8921566 DOI: 10.1136/ijgc-2021-002473] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 12/14/2021] [Indexed: 01/02/2023] Open
Abstract
Radiotherapy with cisplatin (chemoradiation) is the standard treatment for women with locally advanced cervical cancer. Radiotherapy with deep hyperthermia (thermoradiation) is a well established alternative, but is rarely offered as an alternative to chemoradiation, particularly for patients in whom cisplatin is contraindicated. The scope of this review is to provide an overview of the biological rationale of hyperthermia treatment delivery, including patient workflow, and the clinical effectiveness of hyperthermia as a radiosensitizer in the treatment of cervical cancer. Hyperthermia is especially effective in hypoxic and nutrient deprived areas of the tumor where radiotherapy is less effective. Its radiosensitizing effectiveness depends on the temperature level, duration of treatment, and the time interval between radiotherapy and hyperthermia. High quality hyperthermia treatment requires an experienced team, adequate online adaptive treatment planning, and is preferably performed using a phased array radiative locoregional hyperthermia device to achieve the optimal thermal dose effect. Hyperthermia is well tolerated and generally leads to only mild toxicity, such as patient discomfort. Patients in whom cisplatin is contraindicated should therefore be referred to a hyperthermia center for thermoradiation.
Collapse
Affiliation(s)
- Marloes IJff
- Department of Radiation Oncology, Amsterdam University Medical Centers, Cancer Center Amsterdam, University of Amsterdam, Amsterdam, The Netherlands.,Laboratory for Experimental Oncology and Radiobiology (LEXOR), Cancer Center Amsterdam, University of Amsterdam, Amsterdam, The Netherlands
| | - Johannes Crezee
- Department of Radiation Oncology, Amsterdam University Medical Centers, Cancer Center Amsterdam, University of Amsterdam, Amsterdam, The Netherlands
| | - Arlene L Oei
- Department of Radiation Oncology, Amsterdam University Medical Centers, Cancer Center Amsterdam, University of Amsterdam, Amsterdam, The Netherlands.,Laboratory for Experimental Oncology and Radiobiology (LEXOR), Cancer Center Amsterdam, University of Amsterdam, Amsterdam, The Netherlands
| | - Lukas J A Stalpers
- Department of Radiation Oncology, Amsterdam University Medical Centers, Cancer Center Amsterdam, University of Amsterdam, Amsterdam, The Netherlands.,Laboratory for Experimental Oncology and Radiobiology (LEXOR), Cancer Center Amsterdam, University of Amsterdam, Amsterdam, The Netherlands
| | - Henrike Westerveld
- Department of Radiation Oncology, Amsterdam University Medical Centers, Cancer Center Amsterdam, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
13
|
Feasibility, SAR Distribution, and Clinical Outcome upon Reirradiation and Deep Hyperthermia Using the Hypercollar3D in Head and Neck Cancer Patients. Cancers (Basel) 2021; 13:cancers13236149. [PMID: 34885258 PMCID: PMC8656471 DOI: 10.3390/cancers13236149] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 12/04/2021] [Accepted: 12/05/2021] [Indexed: 11/17/2022] Open
Abstract
(1) Background: Head and neck cancer (HNC) patients with recurrent or second primary (SP) tumors in previously irradiated areas represent a clinical challenge. Definitive or postoperative reirradiation with or without sensitizing therapy, like chemotherapy, should be considered. As an alternative to chemotherapy, hyperthermia has shown to be a potent sensitizer of radiotherapy in clinical studies in the primary treatment of HNC. At our institution, we developed the Hypercollar3D, as the successor to the Hypercollar, to enable improved application of hyperthermia for deeply located HNC. In this study, we report on the feasibility and clinical outcome of patients treated with the Hypercollar3D as an adjuvant to reirradiation in recurrent or SP HNC patients; (2) Methods: We retrospectively analyzed all patients with a recurrent or SP HNC treated with reirradiation combined with hyperthermia using the Hypercollar3D between 2014 and 2018. Data on patients, tumors, and treatments were collected. Follow-up data on disease specific outcomes as well as acute and late toxicity were collected. Data were analyzed using Kaplan Meier analyses; (3) Results: Twenty-two patients with recurrent or SP HNC were included. The average mean estimated applied cfSAR to the tumor volume for the last 17 patients was 80.5 W/kg. Therefore, the novel Hypercollar3D deposits 55% more energy at the target than our previous Hypercollar applicator. In patients treated with definitive thermoradiotherapy a complete response rate of 81.8% (9/11) was observed at 12 weeks following radiotherapy. Two-year local control (LC) and overall survival (OS) were 36.4% (95% CI 17.4-55.7%) and 54.6% (95% CI 32.1-72.4%), respectively. Patients with an interval longer than 24 months from their previous radiotherapy course had an LC of 66.7% (95% CI 37.5-84.6%), whereas patients with a time interval shorter than 24 months had an LC of 14.3% (95% CI 0.7-46.5%) at 18 months (p = 0.01). Cumulative grade 3 or higher toxicity was 39.2% (95% CI 16.0-61.9%); (4) Conclusions: Reirradiation combined with deep hyperthermia in HNC patients using the novel Hypercollar3D is feasible and deposits an average cfSAR of 80.5 W/kg in the tumor volume. The treatment results in high complete response rates at 12 weeks post-treatment. Local control and local toxicity rates were comparable to those reported for recurrent or SP HNC. To further optimize the hyperthermia treatment in the future, temperature feedback is warranted to apply heat at the maximum tolerable dose without toxicity. These data support further research in hyperthermia as an adjuvant to radiotherapy, both in the recurrent as well as in the primary treatment of HNC patients.
Collapse
|
14
|
Drizdal T, van Rhoon GC, Verhaart RF, Fiser O, Paulides MM. A Guide for Water Bolus Temperature Selection for Semi-Deep Head and Neck Hyperthermia Treatments Using the HYPERcollar3D Applicator. Cancers (Basel) 2021; 13:cancers13236126. [PMID: 34885235 PMCID: PMC8657004 DOI: 10.3390/cancers13236126] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Accepted: 11/17/2021] [Indexed: 11/16/2022] Open
Abstract
During hyperthermia cancer treatments, especially in semi-deep hyperthermia in the head and neck (H&N) region, the induced temperature pattern is the result of a complex interplay between energy delivery and tissue cooling. The purpose of this study was to establish a water bolus temperature guide for the HYPERcollar3D H&N applicator. First, we measured the HYPERcollar3D water bolus heat-transfer coefficient. Then, for 20 H&N patients and phase/amplitude settings of 93 treatments we predict the T50 for nine heat-transfer coefficients and ten water bolus temperatures ranging from 20-42.5 °C. Total power was always tuned to obtain a maximum of 44 °C in healthy tissue in all simulations. As a sensitivity study we used constant and temperature-dependent tissue cooling properties. We measured a mean heat-transfer coefficient of h = 292 W m-2K-1 for the HYPERcollar3D water bolus. The predicted T50 shows that temperature coverage is more sensitive to the water bolus temperature than to the heat-transfer coefficient. We propose changing the water bolus temperature from 30 °C to 35 °C which leads to a predicted T50 increase of +0.17/+0.55 °C (constant/temperature-dependent) for targets with a median depth < 20 mm from the skin surface. For deeper targets, maintaining a water bolus temperature at 30 °C is proposed.
Collapse
Affiliation(s)
- Tomas Drizdal
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein, 3015 GD Rotterdam, The Netherlands; (G.C.v.R.); (R.F.V.); (M.M.P.)
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, nam. Sitna 3105, 272 01 Kladno, Czech Republic;
- Correspondence:
| | - Gerard C. van Rhoon
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein, 3015 GD Rotterdam, The Netherlands; (G.C.v.R.); (R.F.V.); (M.M.P.)
| | - Rene F. Verhaart
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein, 3015 GD Rotterdam, The Netherlands; (G.C.v.R.); (R.F.V.); (M.M.P.)
| | - Ondrej Fiser
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, nam. Sitna 3105, 272 01 Kladno, Czech Republic;
| | - Margarethus M. Paulides
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus MC Cancer Institute, Dr. Molewaterplein, 3015 GD Rotterdam, The Netherlands; (G.C.v.R.); (R.F.V.); (M.M.P.)
- Department of Electrical Engineering, Eindhoven University of Technology, De Rondom 70, 5612 AP Eindhoven, The Netherlands
| |
Collapse
|
15
|
Androulakis I, Mestrom RMC, Christianen MEMC, Kolkman-Deurloo IKK, van Rhoon GC. Design of the novel ThermoBrachy applicators enabling simultaneous interstitial hyperthermia and high dose rate brachytherapy. Int J Hyperthermia 2021; 38:1660-1671. [PMID: 34814784 DOI: 10.1080/02656736.2021.2005160] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
OBJECTIVE In High Dose Rate Brachytherapy for prostate cancer there is a need for a new way of increasing cancer cell kill in combination with a stable dose to the organs at risk. In this study, we propose a novel ThermoBrachy applicator that offers the unique ability to apply interstitial hyperthermia while simultaneously serving as an afterloading catheter for high dose rate brachytherapy for prostate cancer. This approach achieves a higher thermal enhancement ratio than in sequential application of radiation and hyperthermia and has the potential to decrease the overall treatment time. METHODS The new applicator uses the principle of capacitively coupled electrodes. We performed a proof of concept experiment to demostrate the feasibility of the proposed applicator. Moreover, we used electromagnetic and thermal simulations to evaluate the power needs and temperature homogeneity in different tissues. Furthermore we investigated whether dynamic phase and amplitude adaptation can be used to improve longitudinal temperature control. RESULTS Simulations demonstrate that the electrodes achieve good temperature homogeneity in a homogenous phantom when following current applicator spacing guidelines. Furthermore, we demonstrate that by dynamic phase and amplitude adaptation provides a great advancement for further adaptability of the heating pattern. CONCLUSIONS This newly designed ThermoBrachy applicator has the potential to revise the interest in interstitial thermobrachytherapy, since the simultaneous application of radiation and hyperthermia enables maximum thermal enhancement and at maximum efficiency for patient and organization.
Collapse
Affiliation(s)
- Ioannis Androulakis
- Department of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, The Netherlands
| | - Rob M C Mestrom
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | | | | | - Gerard C van Rhoon
- Department of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, The Netherlands
| |
Collapse
|
16
|
Sumser K, Drizdal T, Bellizzi GG, Hernandez-Tamames JA, van Rhoon GC, Paulides MM. Experimental Validation of the MRcollar: An MR Compatible Applicator for Deep Heating in the Head and Neck Region. Cancers (Basel) 2021; 13:5617. [PMID: 34830773 PMCID: PMC8615935 DOI: 10.3390/cancers13225617] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 10/29/2021] [Accepted: 11/08/2021] [Indexed: 12/13/2022] Open
Abstract
Clinical effectiveness of hyperthermia treatments, in which tumor tissue is artificially heated to 40-44 °C for 60-90 min, can be hampered by a lack of accurate temperature monitoring. The need for noninvasive temperature monitoring in the head and neck region (H&N) and the potential of MR thermometry prompt us to design an MR compatible hyperthermia applicator: the MRcollar. In this work, we validate the design, numerical model, and MR performance of the MRcollar. The MRcollar antennas have low reflection coefficients (<-15 dB) and the intended low interaction between the individual antenna modules (<-32 dB). A 10 °C increase in 3 min was reached in a muscle-equivalent phantom, such that the specifications from the European Society for Hyperthermic Oncology were easily reached. The MRcollar had a minimal effect on MR image quality and a five-fold improvement in SNR was achieved using the integrated coils of the MRcollar, compared to the body coil. The feasibility of using the MRcollar in an MR environment was shown by a synchronous heating experiment. The match between the predicted SAR and measured SAR using MR thermometry satisfied the gamma criteria [distance-to-agreement = 5 mm, dose-difference = 7%]. All experiments combined show that the MRcollar delivers on the needs for MR-hyperthermia in the H&N and is ready for in vivo investigation.
Collapse
Affiliation(s)
- Kemal Sumser
- Department of Radiotherapy, Erasmus Medical Center Cancer Institute, 3015 GD Rotterdam, The Netherlands; (T.D.); (G.G.B.); (G.C.v.R.); (M.M.P.)
| | - Tomas Drizdal
- Department of Radiotherapy, Erasmus Medical Center Cancer Institute, 3015 GD Rotterdam, The Netherlands; (T.D.); (G.G.B.); (G.C.v.R.); (M.M.P.)
- Department of Biomedical Technology, Czech Technical University in Prague, nam. Sítna 3105, 272 01 Kladno, Czech Republic
| | - Gennaro G. Bellizzi
- Department of Radiotherapy, Erasmus Medical Center Cancer Institute, 3015 GD Rotterdam, The Netherlands; (T.D.); (G.G.B.); (G.C.v.R.); (M.M.P.)
| | - Juan A. Hernandez-Tamames
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center Cancer Institute, 3015 GD Rotterdam, The Netherlands;
| | - Gerard C. van Rhoon
- Department of Radiotherapy, Erasmus Medical Center Cancer Institute, 3015 GD Rotterdam, The Netherlands; (T.D.); (G.G.B.); (G.C.v.R.); (M.M.P.)
| | - Margarethus Marius Paulides
- Department of Radiotherapy, Erasmus Medical Center Cancer Institute, 3015 GD Rotterdam, The Netherlands; (T.D.); (G.G.B.); (G.C.v.R.); (M.M.P.)
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
| |
Collapse
|
17
|
Paulides MM, Rodrigues DB, Bellizzi GG, Sumser K, Curto S, Neufeld E, Montanaro H, Kok HP, Dobsicek Trefna H. ESHO benchmarks for computational modeling and optimization in hyperthermia therapy. Int J Hyperthermia 2021; 38:1425-1442. [PMID: 34581246 DOI: 10.1080/02656736.2021.1979254] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND The success of cancer hyperthermia (HT) treatments is strongly dependent on the temperatures achieved in the tumor and healthy tissues as it correlates with treatment efficacy and safety, respectively. Hyperthermia treatment planning (HTP) simulations have become pivotal for treatment optimization due to the possibility for pretreatment planning, optimization and decision making, as well as real-time treatment guidance. MATERIALS AND METHODS The same computational methods deployed in HTP are also used for in silico studies. These are of great relevance for the development of new HT devices and treatment approaches. To aid this work, 3 D patient models have been recently developed and made available for the HT community. Unfortunately, there is no consensus regarding tissue properties, simulation settings, and benchmark applicators, which significantly influence the clinical relevance of computational outcomes. RESULTS AND DISCUSSION Herein, we propose a comprehensive set of applicator benchmarks, efficacy and safety optimization algorithms, simulation settings and clinical parameters, to establish benchmarks for method comparison and code verification, to provide guidance, and in view of the 2021 ESHO Grand Challenge (Details on the ESHO grand challenge on HTP will be provided at https://www.esho.info/). CONCLUSION We aim to establish guidelines to promote standardization within the hyperthermia community such that novel approaches can quickly prove their benefit as quickly as possible in clinically relevant simulation scenarios. This paper is primarily focused on radiofrequency and microwave hyperthermia but, since 3 D simulation studies on heating with ultrasound are now a reality, guidance as well as a benchmark for ultrasound-based hyperthermia are also included.
Collapse
Affiliation(s)
- Margarethus M Paulides
- Electromagnetics for Care & Cure Laboratory (EM4C&C), Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.,Department of Radiotherapy, Erasmus University Medical Center Cancer Institute, Rotterdam, The Netherlands
| | - Dario B Rodrigues
- Hyperthermia Therapy Program, Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, USA
| | - Gennaro G Bellizzi
- Department of Radiotherapy, Erasmus University Medical Center Cancer Institute, Rotterdam, The Netherlands
| | - Kemal Sumser
- Department of Radiotherapy, Erasmus University Medical Center Cancer Institute, Rotterdam, The Netherlands
| | - Sergio Curto
- Department of Radiotherapy, Erasmus University Medical Center Cancer Institute, Rotterdam, The Netherlands
| | - Esra Neufeld
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland
| | - Hazael Montanaro
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland.,Laboratory for Acoustics/Noise control, Swiss Federal Laboratories for Materials Science and Technology (EMPA), Dubendorf, Switzerland
| | - H Petra Kok
- Department of Radiation Oncology, Amsterdam University Medical Centers, University of Amsterdam, Cancer Center Amsterdam, Amsterdam, The Netherlands
| | - Hana Dobsicek Trefna
- Biomedical Electromagnetics Group, Department of Electrical Engineering, Chalmers University of Technology, Göteborg, Sweden
| |
Collapse
|
18
|
Zanoli M, Trefná HD. Suitability of eigenvalue beam-forming for discrete multi-frequency hyperthermia treatment planning. Med Phys 2021; 48:7410-7426. [PMID: 34529281 DOI: 10.1002/mp.15220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Revised: 08/06/2021] [Accepted: 08/06/2021] [Indexed: 11/11/2022] Open
Abstract
PURPOSE Thermal dose delivery in microwave hyperthermia for cancer treatment is expected to benefit from the introduction of ultra-wideband (UWB)-phased array applicators. A full exploitation of the combination of different frequencies to improve the deposition pattern is, however, a nontrivial problem. It is unclear whether the cost functions used for hyperthermia treatment planning (HTP) optimization in the single-frequency setting can be meaningfully extended to the UWB case. METHOD We discuss the ability of the eigenvalue (EV) and a novel implementation of iterative-EV (i-EV) beam-forming methods to fully exploit the available frequency spectrum when a discrete set of simultaneous operating frequencies is available for treatment. We show that the quadratic power deposition ratio solved by the methods can be maximized by only one frequency in the set, therefore rendering EV inadequate for UWB treatment planning. We further investigate whether this represents a limitation in two realistic test cases, comparing the thermal distributions resulting from EV and i-EV to those obtained by optimizing for other nonlinear cost functions that allow for multi-frequency. RESULTS The classical EV-based single-frequency HTP yields systematically lower target SAR deposition and temperature values than nonlinear HTP. In a larynx target, the proposed single-frequency i-EV scheme is able to compensate for this and reach temperatures comparable to those given by global nonlinear optimization. In a meninges target, the multi-frequency setting outperforms the single-frequency one, achieving better target coverage and 0 . 5 ∘ C higher T 90 in the tumor than single-frequency-based HTP. CONCLUSIONS Classical EV performs poorly in terms of resulting target temperatures. The proposed single-frequency i-EV scheme can be a viable option depending on the patient and tumor to be treated, as long as the proper operating frequency can be selected across a UWB range. Multi-frequency HTP can bring a considerable benefit in regions typically difficult to treat such as the brain.
Collapse
Affiliation(s)
- Massimiliano Zanoli
- Department of Electrical Engineering, Chalmers University of Technology, Göteborg, Sweden
| | - Hana Dobšíček Trefná
- Department of Electrical Engineering, Chalmers University of Technology, Göteborg, Sweden
| |
Collapse
|
19
|
|
20
|
VilasBoas-Ribeiro I, Curto S, van Rhoon GC, Franckena M, Paulides MM. MR Thermometry Accuracy and Prospective Imaging-Based Patient Selection in MR-Guided Hyperthermia Treatment for Locally Advanced Cervical Cancer. Cancers (Basel) 2021; 13:cancers13143503. [PMID: 34298716 PMCID: PMC8303939 DOI: 10.3390/cancers13143503] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 07/02/2021] [Accepted: 07/05/2021] [Indexed: 11/17/2022] Open
Abstract
Simple Summary Monitoring and controlling the temperature distribution combined with precise energy delivery are key components for hyperthermia treatment success. Magnetic resonance (MR) imaging is used clinically to monitor the temperature of the treated volume non-invasively. However, there are no comprehensive systematic studies on MR thermometry accuracy during deep pelvic hyperthermia, and the few investigational studies suffer from a high probability of bias due to lacking objective criteria for data inclusion. This study presents the first systematic analysis and defines an imaging-based criterion for prospective patient selection to standardize clinical MR thermometry accuracy assessments. Abstract The efficacy of a hyperthermia treatment depends on the delivery of well-controlled heating; hence, accurate temperature monitoring is essential for ensuring effective treatment. For deep pelvic hyperthermia, there are no comprehensive and systematic reports on MR thermometry. Moreover, data inclusion generally lacks objective selection criteria leading to a high probability of bias when comparing results. Herein, we studied whether imaging-based data inclusion predicts accuracy and could serve as a tool for prospective patient selection. The accuracy of the MR thermometry in patients with locally advanced cervical cancer was benchmarked against intraluminal temperature. We found that gastrointestinal air motion at the start of the treatment, quantified by the Jaccard similarity coefficient, was a good predictor for MR thermometry accuracy. The results for the group that was selected for low gastrointestinal air motion improved compared to the results for all patients by 50% (accuracy), 26% (precision), and 80% (bias). We found an average MR thermometry accuracy of 2.0 °C when all patients were considered and 1.0 °C for the selected group. These results serve as the basis for comprehensive benchmarking of novel technologies. The Jaccard similarity coefficient also has good potential to prospectively determine in which patients the MR thermometry will be valuable.
Collapse
Affiliation(s)
- Iva VilasBoas-Ribeiro
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands; (S.C.); (G.C.v.R.); (M.F.); (M.M.P.)
- Correspondence:
| | - Sergio Curto
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands; (S.C.); (G.C.v.R.); (M.F.); (M.M.P.)
| | - Gerard C. van Rhoon
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands; (S.C.); (G.C.v.R.); (M.F.); (M.M.P.)
- Department of Radiation Science and Technology, Faculty of Applied Sciences, Delft University of Technology, 2629 JB Delft, The Netherlands
| | - Martine Franckena
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands; (S.C.); (G.C.v.R.); (M.F.); (M.M.P.)
| | - Margarethus M. Paulides
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands; (S.C.); (G.C.v.R.); (M.F.); (M.M.P.)
- Center for Care and Cure Technologies Eindhoven (C3Te), Department of Electrical Engineering, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands
| |
Collapse
|
21
|
Kok HP, van der Zee J, Guirado FN, Bakker A, Datta NR, Abdel-Rahman S, Schmidt M, Wust P, Crezee J. Treatment planning facilitates clinical decision making for hyperthermia treatments. Int J Hyperthermia 2021; 38:532-551. [PMID: 33784914 DOI: 10.1080/02656736.2021.1903583] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
Background: Treatment quality is important in clinical hyperthermia. Guideline-based treatment protocols are used to determine system settings and treatment strategies to ensure effective tumor heating and prevent unwanted treatment-limiting normal tissue hot spots. Realizing both these goals can prove challenging using generic guideline-based and operator-dependent treatment strategies. Hyperthermia treatment planning (HTP) can be very useful to support treatment strategies. Although HTP is increasingly integrated into the standard clinical workflow, active clinical application is still limited to a small number of hyperthermia centers and should be further stimulated.Purpose: This paper aims to serve as a practical guide, demonstrating how HTP can be applied in clinical decision making for both superficial and locoregional hyperthermia treatments.HTP in clinical decision making: Seven problems that occur in daily clinical practice are described and we show how HTP can enhance insight to formulate an adequate treatment strategy. Examples use representative commercially available hyperthermia devices and cover all stages during the clinical workflow. Problems include selecting adequate phase settings, heating ability analysis, hot spot suppression, applicator selection, evaluation of target coverage and heating depth, and predicting possible thermal toxicity in case of an implant. Since we aim to promote a general use of HTP in daily practice, basic simulation strategies are used in these problems, avoiding a need for the application of dedicated advanced optimization routines that are not generally available.Conclusion: Even fairly basic HTP can facilitate clinical decision making, providing a meaningful and clinically relevant contribution to maintaining and improving treatment quality.
Collapse
Affiliation(s)
- H P Kok
- Department of Radiation Oncology, Cancer Center Amsterdam, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - J van der Zee
- Department of Radiation Oncology, Erasmus MC, Rotterdam, The Netherlands
| | - F Navarro Guirado
- Department of Medical Physics, Regional University Hospital of Málaga, Malaga, Spain
| | - A Bakker
- Department of Radiation Oncology, Cancer Center Amsterdam, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - N R Datta
- Kantonsspital Aarau, Centre for Radiation Oncology KSA-KSB, Aarau, Switzerland
| | - S Abdel-Rahman
- Department of Medicine III, University Hospital LMU Munich, Munich, Germany
| | - M Schmidt
- Department of Radiation Oncology, University Hospital Erlangen, Erlangen, Germany
| | - P Wust
- Department of Radiation Oncology, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - J Crezee
- Department of Radiation Oncology, Cancer Center Amsterdam, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
22
|
Bellizzi GG, Sumser K, VilasBoas-Ribeiro I, Curto S, Drizdal T, van Rhoon GC, Franckena M, Paulides MM. Standardization of patient modeling in hyperthermia simulation studies: introducing the Erasmus Virtual Patient Repository. Int J Hyperthermia 2021; 37:608-616. [PMID: 32515240 DOI: 10.1080/02656736.2020.1772996] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
Purpose: Thermal dose-effect relations have demonstrated that clinical effectiveness of hyperthermia would benefit from more controlled heating of the tumor. Hyperthermia treatment planning (HTP) is a potent tool to study strategies enabling target conformal heating, but its accuracy is affected by patient modeling approximations. Homogeneous phantoms models are being used that do not match the body shape of patients in treatment position and often have unrealistic target volumes. As a consequence, simulation accuracy is affected, and performance comparisons are difficult. The aim of this study is to provide the first step toward standardization of HTP simulation studies in terms of patient modeling by introducing the Erasmus Virtual Patient Repository (EVPR): a virtual patient model database.Methods: Four patients with a tumor in the head and neck or the pelvis region were selected, and corresponding models were created using a clinical segmentation procedure. Using the Erasmus University Medical Center standard procedure, HTP was applied to these models and compared to HTP for commonly used surrogate models.Results: Although this study was aimed at presenting the EVPR database, our study illustrates that there is a non-negligible difference in the predicted SAR patterns between patient models and homogeneous phantom-based surrogate models. We further demonstrate the difference between actual and simplified target volumes being used today.Conclusion: Our study describes the EVPR for the research community as a first step toward standardization of hyperthermia simulation studies.
Collapse
Affiliation(s)
- Gennaro G Bellizzi
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Kemal Sumser
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Iva VilasBoas-Ribeiro
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Sergio Curto
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Tomas Drizdal
- Department of Biomedical Technology, Czech Technical University in Prague, Prague, Czech Republic
| | - Gerard C van Rhoon
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Martine Franckena
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Margarethus M Paulides
- Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands.,Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
23
|
Kok HP, Cressman ENK, Ceelen W, Brace CL, Ivkov R, Grüll H, Ter Haar G, Wust P, Crezee J. Heating technology for malignant tumors: a review. Int J Hyperthermia 2021; 37:711-741. [PMID: 32579419 DOI: 10.1080/02656736.2020.1779357] [Citation(s) in RCA: 139] [Impact Index Per Article: 46.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
The therapeutic application of heat is very effective in cancer treatment. Both hyperthermia, i.e., heating to 39-45 °C to induce sensitization to radiotherapy and chemotherapy, and thermal ablation, where temperatures beyond 50 °C destroy tumor cells directly are frequently applied in the clinic. Achievement of an effective treatment requires high quality heating equipment, precise thermal dosimetry, and adequate quality assurance. Several types of devices, antennas and heating or power delivery systems have been proposed and developed in recent decades. These vary considerably in technique, heating depth, ability to focus, and in the size of the heating focus. Clinically used heating techniques involve electromagnetic and ultrasonic heating, hyperthermic perfusion and conductive heating. Depending on clinical objectives and available technology, thermal therapies can be subdivided into three broad categories: local, locoregional, or whole body heating. Clinically used local heating techniques include interstitial hyperthermia and ablation, high intensity focused ultrasound (HIFU), scanned focused ultrasound (SFUS), electroporation, nanoparticle heating, intraluminal heating and superficial heating. Locoregional heating techniques include phased array systems, capacitive systems and isolated perfusion. Whole body techniques focus on prevention of heat loss supplemented with energy deposition in the body, e.g., by infrared radiation. This review presents an overview of clinical hyperthermia and ablation devices used for local, locoregional, and whole body therapy. Proven and experimental clinical applications of thermal ablation and hyperthermia are listed. Methods for temperature measurement and the role of treatment planning to control treatments are discussed briefly, as well as future perspectives for heating technology for the treatment of tumors.
Collapse
Affiliation(s)
- H Petra Kok
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Erik N K Cressman
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Wim Ceelen
- Department of GI Surgery, Ghent University Hospital, Ghent, Belgium
| | - Christopher L Brace
- Department of Radiology and Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Robert Ivkov
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA.,Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.,Department of Mechanical Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA.,Department of Materials Science and Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Holger Grüll
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital of Cologne, University of Cologne, Cologne, Germany
| | - Gail Ter Haar
- Department of Physics, The Institute of Cancer Research, London, UK
| | - Peter Wust
- Department of Radiation Oncology, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Johannes Crezee
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
24
|
Drizdal T, Sumser K, Bellizzi GG, Fiser O, Vrba J, Rhoon GCV, Yeo DTB, Margarethus M Paulides. Simulation guided design of the MRcollar: a MR compatible applicator for deep heating in the head and neck region. Int J Hyperthermia 2021; 38:382-392. [PMID: 33682594 DOI: 10.1080/02656736.2021.1892836] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
PURPOSE To develop a head and neck hyperthermia phased array system compatible with a 1.5 T magnetic resonance (MR) scanner for noninvasive thermometry. METHODS We designed a dielectric-parabolic-reflector antenna (DiPRA) based on a printed reflector backed dipole antenna and studied its predicted and measured performance in a flat configuration (30 mm thick water bolus and muscle equivalent layer). Thereafter, we designed a phased array applicator model ('MRcollar') consisting of 12 DiPRA modules placed on a radius of 180 mm. Theoretical heating performance of the MRcollar model was benchmarked against the current clinical applicator (HYPERcollar3D) using specific (3D) head and neck models of 28 treated patients. Lastly, we assessed the influence of the DiPRA modules on MR scanning quality. RESULTS The predicted and measured reflection coefficients (S11) of the DiPRA module are below -20 dB. The maximum specific absorption rate (SAR) in the area under the antenna was 47% higher than for the antenna without encasing. Compared to the HYPERcollar3D, the MRcollar design incorporates 31% less demineralized water (-2.5 L), improves the predicted TC25 (target volume enclosed by 25% iso-SAR contour) by 4.1% and TC50 by 8.5%, while the target-to-hotspot quotient (THQ) is minimally affected (-1.6%). MR experiments showed that the DiPRA modules do not affect MR transmit/receive performance. CONCLUSION Our results suggest that head and neck hyperthermia delivery quality with the MRcollar can be maintained, while facilitating simultaneous noninvasive MR thermometry for treatment monitoring and control.
Collapse
Affiliation(s)
- Tomas Drizdal
- Hyperthermia Unit, Department of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, The Netherlands.,Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic, Kladno, Czech Republic in Prague
| | - Kemal Sumser
- Hyperthermia Unit, Department of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, The Netherlands
| | - Gennaro G Bellizzi
- Hyperthermia Unit, Department of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, The Netherlands.,Department of Information Engineering, Infrastructures and Sustainable Energy, Universita Mediterranea di Reggio Calabria, Reggio di Calabria, Italy
| | - Ondrej Fiser
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic, Kladno, Czech Republic in Prague
| | - Jan Vrba
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic, Kladno, Czech Republic in Prague
| | - Gerard C van Rhoon
- Hyperthermia Unit, Department of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, The Netherlands
| | - Desmond T B Yeo
- Imaging and Bioelectronic Technologies, GE Global Research Centre, Niskayuna, NY, USA
| | - Margarethus M Paulides
- Hyperthermia Unit, Department of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, The Netherlands.,Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
25
|
Abstract
Time-reversal (TR) is a known wideband array beam-forming technique that has been suggested as a treatment planning alternative in deep microwave hyperthermia for cancer treatment. While the aim in classic TR is to focus the energy at a specific point within the target, no assumptions are made on secondary lobes that might arise in the healthy tissues. These secondary lobes, together with tissue heterogeneity, may result in hot-spots (HSs), which are known to limit the efficiency of the thermal dose delivery to the tumor. This paper proposes a novel wideband TR focusing method that iteratively shifts the focus away from HSs and towards cold-spots from an initial TR solution, a procedure that improves tumor coverage and reduces HSs. We verify this method on two different applicator topologies and several target volume configurations. The algorithm is deterministic and runs within seconds, enabling its use for real-time applications. At the same time, it yields results comparable to those obtained with global stochastic optimizers such as Particle Swarm.
Collapse
Affiliation(s)
- Massimiliano Zanoli
- Dept. Electrical Engineering, Chalmers University of Technology, Gothenburg, SE, Sweden
| | - Hana Dobšíček Trefná
- Dept. Electrical Engineering, Chalmers University of Technology, Gothenburg, SE, Sweden
| |
Collapse
|
26
|
Asadi S, Bianchi L, De Landro M, Korganbayev S, Schena E, Saccomandi P. Laser-induced optothermal response of gold nanoparticles: From a physical viewpoint to cancer treatment application. JOURNAL OF BIOPHOTONICS 2021; 14:e202000161. [PMID: 32761778 DOI: 10.1002/jbio.202000161] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 07/15/2020] [Accepted: 07/28/2020] [Indexed: 06/11/2023]
Abstract
Gold nanoparticles (GNPs)-based photothermal therapy (PTT) is a promising minimally invasive thermal therapy for the treatment of focal malignancies. Although GNPs-based PTT has been known for over two decades and GNPs possess unique properties as therapeutic agents, the delivery of a safe and effective therapy is still an open question. This review aims at providing relevant and recent information on the usage of GNPs in combination with the laser to treat cancers, pointing out the practical aspects that bear on the therapy outcome. Emphasis is given to the assessment of the GNPs' properties and the physical mechanisms underlying the laser-induced heat generation in GNPs-loaded tissues. The main techniques available for temperature measurement and the current theoretical simulation approaches predicting the therapeutic outcome are reviewed. Topical challenges in delivering safe thermal dosage are also presented with the aim to discuss the state-of-the-art and the future perspective in the field of GNPs-mediated PTT.
Collapse
Affiliation(s)
- Somayeh Asadi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Leonardo Bianchi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Martina De Landro
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | | | - Emiliano Schena
- Laboratory of Measurement and Biomedical Instrumentation, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
27
|
VilasBoas-Ribeiro I, van Rhoon GC, Drizdal T, Franckena M, Paulides MM. Impact of Number of Segmented Tissues on SAR Prediction Accuracy in Deep Pelvic Hyperthermia Treatment Planning. Cancers (Basel) 2020; 12:cancers12092646. [PMID: 32947939 PMCID: PMC7563220 DOI: 10.3390/cancers12092646] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 09/10/2020] [Accepted: 09/14/2020] [Indexed: 11/16/2022] Open
Abstract
Simple Summary Hyperthermia treatment planning is the process of optimizing treatment quality using pre-treatment simulations. Although it has become a powerful tool, prediction accuracy is strongly dependent on the patient model. For deep hyperthermia in the pelvis, it is common that only four tissue categories are discriminated (bone, fat, muscle-like, and tumor). For the head and neck region, more tissues have been shown to be required for good prediction accuracy. Delineating is a labor-intensive and difficult process. Hence, it is important to find the optimum between accuracy and labor, but for deep pelvic hyperthermia, there are no published studies showing the impact of the number of tissues. We studied the trade-off between the segmentation detail needed and segmentation feasibility. Our findings indicate that including high water content tissues can impact simulation accuracy. Although our results, in general, underline the suitability of our current clinical protocol, they help to prioritize improvements for specific cases. Abstract In hyperthermia, the general opinion is that pre-treatment optimization of treatment settings requires a patient-specific model. For deep pelvic hyperthermia treatment planning (HTP), tissue models comprising four tissue categories are currently discriminated. For head and neck HTP, we found that more tissues are required for increasing accuracy. In this work, we evaluated the impact of the number of segmented tissues on the predicted specific absorption rate (SAR) for the pelvic region. Highly detailed anatomical models of five healthy volunteers were selected from a virtual database. For each model, seven lists with varying levels of segmentation detail were defined and used as an input for a modeling study. SAR changes were quantified using the change in target-to-hotspot-quotient and maximum SAR relative differences, with respect to the most detailed patient model. The main finding of this study was that the inclusion of high water content tissues in the segmentation may result in a clinically relevant impact on the SAR distribution and on the predicted hyperthermia treatment quality when considering our pre-established thresholds. In general, our results underline the current clinical segmentation protocol and help to prioritize any improvements.
Collapse
Affiliation(s)
- Iva VilasBoas-Ribeiro
- Department of Radiation Oncology, Erasmus MC Cancer Institute, 3015 GD Rotterdam, The Netherlands; (G.C.v.R.); (M.F.); (M.M.P.)
- Correspondence:
| | - Gerard C. van Rhoon
- Department of Radiation Oncology, Erasmus MC Cancer Institute, 3015 GD Rotterdam, The Netherlands; (G.C.v.R.); (M.F.); (M.M.P.)
- Department of Radiation Science and Technology, Faculty of Applied Sciences, Delft University of Technology, 2629 JB Delft, The Netherlands
| | - Tomas Drizdal
- Department of Biomedical Technology, Czech Technical University in Prague, nam. Sitna 3105, 272 01 Kladno, Czech Republic;
| | - Martine Franckena
- Department of Radiation Oncology, Erasmus MC Cancer Institute, 3015 GD Rotterdam, The Netherlands; (G.C.v.R.); (M.F.); (M.M.P.)
| | - Margarethus M. Paulides
- Department of Radiation Oncology, Erasmus MC Cancer Institute, 3015 GD Rotterdam, The Netherlands; (G.C.v.R.); (M.F.); (M.M.P.)
- Electromagnetics for Care & Cure (EM-4C&C) Laboratory, Center for Care and Cure Technologies Eindhoven (C3Te), Department of Electrical Engineering, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands
| |
Collapse
|
28
|
Datta NR, Kok HP, Crezee H, Gaipl US, Bodis S. Integrating Loco-Regional Hyperthermia Into the Current Oncology Practice: SWOT and TOWS Analyses. Front Oncol 2020; 10:819. [PMID: 32596144 PMCID: PMC7303270 DOI: 10.3389/fonc.2020.00819] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Accepted: 04/27/2020] [Indexed: 12/14/2022] Open
Abstract
Moderate hyperthermia at temperatures between 40 and 44°C is a multifaceted therapeutic modality. It is a potent radiosensitizer, interacts favorably with a host of chemotherapeutic agents, and, in combination with radiotherapy, enforces immunomodulation akin to “in situ tumor vaccination.” By sensitizing hypoxic tumor cells and inhibiting repair of radiotherapy-induced DNA damage, the properties of hyperthermia delivered together with photons might provide a tumor-selective therapeutic advantage analogous to high linear energy transfer (LET) neutrons, but with less normal tissue toxicity. Furthermore, the high LET attributes of hyperthermia thermoradiobiologically are likely to enhance low LET protons; thus, proton thermoradiotherapy would mimic 12C ion therapy. Hyperthermia with radiotherapy and/or chemotherapy substantially improves therapeutic outcomes without enhancing normal tissue morbidities, yielding level I evidence reported in several randomized clinical trials, systematic reviews, and meta-analyses for various tumor sites. Technological advancements in hyperthermia delivery, advancements in hyperthermia treatment planning, online invasive and non-invasive MR-guided thermometry, and adherence to quality assurance guidelines have ensured safe and effective delivery of hyperthermia to the target region. Novel biological modeling permits integration of hyperthermia and radiotherapy treatment plans. Further, hyperthermia along with immune checkpoint inhibitors and DNA damage repair inhibitors could further augment the therapeutic efficacy resulting in synthetic lethality. Additionally, hyperthermia induced by magnetic nanoparticles coupled to selective payloads, namely, tumor-specific radiotheranostics (for both tumor imaging and radionuclide therapy), chemotherapeutic drugs, immunotherapeutic agents, and gene silencing, could provide a comprehensive tumor-specific theranostic modality akin to “magic (nano)bullets.” To get a realistic overview of the strength (S), weakness (W), opportunities (O), and threats (T) of hyperthermia, a SWOT analysis has been undertaken. Additionally, a TOWS analysis categorizes future strategies to facilitate further integration of hyperthermia with the current treatment modalities. These could gainfully accomplish a safe, versatile, and cost-effective enhancement of the existing therapeutic armamentarium to improve outcomes in clinical oncology.
Collapse
Affiliation(s)
- Niloy R Datta
- Centre for Radiation Oncology KSA-KSB, Kantonsspital Aarau, Aarau, Switzerland
| | - H Petra Kok
- Department of Radiation Oncology, Cancer Center Amsterdam, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Hans Crezee
- Department of Radiation Oncology, Cancer Center Amsterdam, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Udo S Gaipl
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Stephan Bodis
- Centre for Radiation Oncology KSA-KSB, Kantonsspital Aarau, Aarau, Switzerland
| |
Collapse
|
29
|
Sumser K, Bellizzi GG, van Rhoon GC, Paulides MM. The Potential of Adjusting Water Bolus Liquid Properties for Economic and Precise MR Thermometry Guided Radiofrequency Hyperthermia. SENSORS 2020; 20:s20102946. [PMID: 32456027 PMCID: PMC7288164 DOI: 10.3390/s20102946] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 05/14/2020] [Accepted: 05/21/2020] [Indexed: 11/23/2022]
Abstract
The potential of MR thermometry (MRT) fostered the development of MRI compatible radiofrequency (RF) hyperthermia devices. Such device integration creates major technological challenges and a crucial point for image quality is the water bolus (WB). The WB is located between the patient body and external sources to both couple electromagnetic energy and to cool the patient skin. However, the WB causes MRT errors and unnecessarily large field of view. In this work, we studied making the WB MRI transparent by an optimal concentration of compounds capable of modifying T2* relaxation without an impact on the efficiency of RF heating. Three different T2* reducing compounds were investigated, namely CuSO4, MnCl2, and Fe3O4. First, electromagnetic properties and T2* relaxation rates at 1.5 T were measured. Next, through multi-physics simulations, the predicted effect on the RF-power deposition pattern was evaluated and MRT precision was experimentally assessed. Our results identified 5 mM Fe3O4 solution as optimal since it does not alter the RF-power level needed and improved MRT precision from 0.39 °C to 0.09 °C. MnCl2 showed a similar MRT improvement, but caused unacceptable RF-power losses. We conclude that adding Fe3O4 has significant potential to improve RF hyperthermia treatment monitoring under MR guidance.
Collapse
Affiliation(s)
- Kemal Sumser
- Department of Radiation Oncology, Erasmus MC—Cancer Institute, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands; (G.G.B.); (G.C.v.R.); (M.M.P.)
- Correspondence:
| | - Gennaro G. Bellizzi
- Department of Radiation Oncology, Erasmus MC—Cancer Institute, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands; (G.G.B.); (G.C.v.R.); (M.M.P.)
| | - Gerard C. van Rhoon
- Department of Radiation Oncology, Erasmus MC—Cancer Institute, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands; (G.G.B.); (G.C.v.R.); (M.M.P.)
| | - Margarethus M. Paulides
- Department of Radiation Oncology, Erasmus MC—Cancer Institute, University Medical Center Rotterdam, 3015 GD Rotterdam, The Netherlands; (G.G.B.); (G.C.v.R.); (M.M.P.)
- EM4C&C Laboratory, Center for Care & Cure Technology Eindhoven (C3Te), Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
| |
Collapse
|
30
|
Solving the Time- and Frequency-Multiplexed Problem of Constrained Radiofrequency Induced Hyperthermia. Cancers (Basel) 2020; 12:cancers12051072. [PMID: 32344914 PMCID: PMC7281622 DOI: 10.3390/cancers12051072] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 04/21/2020] [Accepted: 04/24/2020] [Indexed: 11/26/2022] Open
Abstract
Targeted radiofrequency (RF) heating induced hyperthermia has a wide range of applications, ranging from adjunct anti-cancer treatment to localized release of drugs. Focal RF heating is usually approached using time-consuming nonconvex optimization procedures or approximations, which significantly hampers its application. To address this limitation, this work presents an algorithm that recasts the problem as a semidefinite program and quickly solves it to global optimality, even for very large (human voxel) models. The target region and a desired RF power deposition pattern as well as constraints can be freely defined on a voxel level, and the optimum application RF frequencies and time-multiplexed RF excitations are automatically determined. 2D and 3D example applications conducted for test objects containing pure water (rtarget = 19 mm, frequency range: 500–2000 MHz) and for human brain models including brain tumors of various size (r1 = 20 mm, r2 = 30 mm, frequency range 100–1000 MHz) and locations (center, off-center, disjoint) demonstrate the applicability and capabilities of the proposed approach. Due to its high performance, the algorithm can solve typical clinical problems in a few seconds, making the presented approach ideally suited for interactive hyperthermia treatment planning, thermal dose and safety management, and the design, rapid evaluation, and comparison of RF applicator configurations.
Collapse
|
31
|
Paulides M, Dobsicek Trefna H, Curto S, Rodrigues D. Recent technological advancements in radiofrequency- andmicrowave-mediated hyperthermia for enhancing drug delivery. Adv Drug Deliv Rev 2020; 163-164:3-18. [PMID: 32229271 DOI: 10.1016/j.addr.2020.03.004] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 03/20/2020] [Accepted: 03/24/2020] [Indexed: 12/23/2022]
Abstract
Hyperthermia therapy is a potent enhancer of chemotherapy and radiotherapy. In particular, microwave (MW) and radiofrequency (RF) hyperthermia devices provide a variety of heating approaches that can treat most cancers regardless the size. This review introduces the physics of MW/RF hyperthermia, the current state-of-the-art systems for both localized and regional heating, and recent advancements in hyperthermia treatment guidance using real-time computational simulations and magnetic resonance thermometry. Clinical trials involving RF/MW hyperthermia as adjuvant for chemotherapy are also presented per anatomical site. These studies favor the use of adjuvant hyperthermia since it significantly improves curative and palliative clinical outcomes. The main challenge of hyperthermia is the distribution of state-of-the-art heating systems. Nevertheless, we anticipate that recent technology advances will expand the use of hyperthermia to chemotherapy centers for enhanced drug delivery. These new technologies hold great promise not only for (image-guided) perfusion modulation and sensitization for cytotoxic drugs, but also for local delivery of various compounds using thermosensitive liposomes.
Collapse
|
32
|
Role of Simulations in the Treatment Planning of Radiofrequency Hyperthermia Therapy in Clinics. JOURNAL OF ONCOLOGY 2019; 2019:9685476. [PMID: 31558904 PMCID: PMC6735211 DOI: 10.1155/2019/9685476] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Revised: 07/20/2019] [Accepted: 07/28/2019] [Indexed: 12/26/2022]
Abstract
Hyperthermia therapy is a treatment modality in which tumor temperatures are elevated to higher temperatures to cause damage to cancerous tissues. Numerical simulations are integral in the development of hyperthermia treatment systems and in clinical treatment planning. In this study, simulations in radiofrequency hyperthermia therapy are reviewed in terms of their technical development and clinical aspects for effective clinical use. This review offers an overview of mathematical models and the importance of tissue properties; locoregional mild hyperthermia therapy, including phantom and realistic human anatomy models; phase array systems; tissue damage; thermal dose analysis; and thermoradiotherapy planning. This review details the improvements in numerical approaches in treatment planning and their application for effective clinical use. Furthermore, the modeling of thermoradiotherapy planning, which can be integrated with radiotherapy to provide combined hyperthermia and radiotherapy treatment planning strategies, are also discussed. This review may contribute to the effective development of thermoradiotherapy planning in clinics.
Collapse
|
33
|
Sumser K, Neufeld E, Verhaart RF, Fortunati V, Verduijn GM, Drizdal T, van Walsum T, Veenland JF, Paulides MM. Feasibility and relevance of discrete vasculature modeling in routine hyperthermia treatment planning. Int J Hyperthermia 2019; 36:801-811. [DOI: 10.1080/02656736.2019.1641633] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Affiliation(s)
- Kemal Sumser
- Department of Radiation Oncology, University Medical Center Rotterdam, Erasmus MC – Cancer Institute, Rotterdam, The Netherlands
| | - Esra Neufeld
- Computational Life Sciences Group, Foundation for Research on Information Technologies in Society (IT’IS), Zurich, Switzerland
| | - René F. Verhaart
- Department of Radiation Oncology, University Medical Center Rotterdam, Erasmus MC – Cancer Institute, Rotterdam, The Netherlands
| | - Valerio Fortunati
- Department of Medical Informatics and Radiology, University Medical Center Rotterdam, Erasmus MC, Rotterdam, The Netherlands
| | - Gerda M. Verduijn
- Department of Radiation Oncology, University Medical Center Rotterdam, Erasmus MC – Cancer Institute, Rotterdam, The Netherlands
| | - Tomas Drizdal
- Department of Radiation Oncology, University Medical Center Rotterdam, Erasmus MC – Cancer Institute, Rotterdam, The Netherlands
- Department of Biomedical Technology, Czech Technical University in Prague, Prague, Czech Republic
| | - Theo van Walsum
- Department of Medical Informatics and Radiology, University Medical Center Rotterdam, Erasmus MC, Rotterdam, The Netherlands
| | - Jifke F. Veenland
- Department of Medical Informatics and Radiology, University Medical Center Rotterdam, Erasmus MC, Rotterdam, The Netherlands
| | - Margarethus M. Paulides
- Department of Radiation Oncology, University Medical Center Rotterdam, Erasmus MC – Cancer Institute, Rotterdam, The Netherlands
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
34
|
Bellizzi GG, Drizdal T, van Rhoon GC, Crocco L, Isernia T, Paulides MM. The potential of constrained SAR focusing for hyperthermia treatment planning: analysis for the head & neck region. Phys Med Biol 2018; 64:015013. [PMID: 30523869 DOI: 10.1088/1361-6560/aaf0c4] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Clinical trials have shown that hyperthermia is a potent adjuvant to conventional cancer treatments, but the temperatures currently achieved in the clinic are still suboptimal. Hyperthermia treatment planning simulations have potential to improve the heating profile of phased-array applicators. An important open challenge is the development of an effective optimization procedure that enables uniform heating of the target region while keeping temperature below a threshold in healthy tissues. In this work, we analyzed the effectiveness and efficiency of a recently proposed optimization approach, i.e. focusing via constrained power optimization (FOCO), using 3D simulations of twelve clinical patient specific models. FOCO performance was compared against a clinically used particle swarm based optimization approach. Evaluation metrics were target coverage at the 25% iso-SAR level, target hotspot quotient, median target temperature (T50) and computational requirements. Our results show that, on average, constrained power focusing performs slightly better than the clinical benchmark ([Formula: see text]T50 [Formula: see text] °C), but outperforms this clinical benchmark for large target volumes ([Formula: see text]40 cm[Formula: see text], [Formula: see text]T50 [Formula: see text] °C). In addition, the results are achieved in a shorter time ([Formula: see text]%) and are repeatable because the approach is formulated as a convex optimization problem.
Collapse
Affiliation(s)
- G G Bellizzi
- Universitá Mediterranea di Reggio Calabria, DIIES, Reggio di Calabria, Italy. Erasmus Medical Center, Radiation Oncology Department, Hyperthermia Unit, Rotterdam, The Netherlands. IREA-CNR, Institute for Electromagnetic Sensing of the Environment, National Research Council of Italy, Napoli, Italy. Author to whom any correspondence should be addressed
| | | | | | | | | | | |
Collapse
|
35
|
Datta NR, Stutz E, Gomez S, Bodis S. Efficacy and Safety Evaluation of the Various Therapeutic Options in Locally Advanced Cervix Cancer: A Systematic Review and Network Meta-Analysis of Randomized Clinical Trials. Int J Radiat Oncol Biol Phys 2018; 103:411-437. [PMID: 30391522 DOI: 10.1016/j.ijrobp.2018.09.037] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 09/21/2018] [Accepted: 09/25/2018] [Indexed: 01/10/2023]
Abstract
Treatment options in locally advanced cervix cancer (LACC) have evolved around radiation therapy (RT) and/or chemotherapy (CT), hypoxic cell sensitizers, immunomodulators (Imm), and locoregional moderate hyperthermia (HT). A systematic review and network meta-analysis was conducted to synthesize the evidence for efficacy and safety in terms of long-term locoregional control (LRC), overall survival (OS), and grade ≥3 acute morbidity (AM) and late morbidity (LM). Five databases were searched, and 6285 articles (1974-2018) were screened per the Preferred Reporting Items for Systematic Reviews and Meta-analysis guidelines. Fifty-nine randomized trials in untreated LACC without surgical intervention were shortlisted. These used 13 different interventions: RT alone and/or neoadjuvant CT (NACT), adjuvant CT (ACT), concurrent chemoradiation therapy (CTRT) (weekly cisplatin [CDDP]/3-weekly CDDP/combination CT with CDDP/non-CDDP-based CT), hypoxic cell sensitizers, Imm, or HT. Odds ratios (ORs) using random effects network meta-analysis were estimated. Interventions for each endpoint were ranked according to their corresponding surface under cumulative ranking curve values. Of the 9894 patients evaluated, the total events reported for LRC, OS, AM, and LM were 5431 of 8197, 4482 of 7958, 1710 of 7183, and 441 of 6333, respectively. ORs and 95% credible intervals (CrIs) for the 2 best strategies were HT + RT versus CTRT + ACT (OR, 1.23; 95% CrI, 0.49-3.19) for LRC, CTRT (3-weekly CDDP) versus HTCTRT (OR, 1.14; 95% CrI, 0.35-3.65) for OS, RT + ACT versus RT (OR, 0.01; 95% CrI, 0.00-1.04) for AM, and NACT + RT + ACT versus RT + Imm (OR, 0.42; 95% CrI, 0.02-7.39) for LM. The 3 interventions with the highest cumulative surface under cumulative ranking curve values for all 4 endpoints were HTRT, HTCTRT, and CTRT (3-weekly CDDP). Articles with low risk of bias and those published during 2004 to 2018 also retained these interventions as the best. Two-step cluster analysis grouped these 3 modalities in a single distinctive cluster. HTRT, HTCTRT, and CTRT with 3-weekly CDDP were identified as therapeutic modalities with the best comprehensive impact on key clinical endpoints in LACC. This warrants a phase 3 randomized trial among these strategies for a head-to-head comparison and additional validation.
Collapse
Affiliation(s)
- Niloy R Datta
- Centre for Radiation Oncology KSA-KSB, Kantonsspital Aarau, Switzerland.
| | - Emanuel Stutz
- Centre for Radiation Oncology KSA-KSB, Kantonsspital Aarau, Switzerland
| | - Silvia Gomez
- Centre for Radiation Oncology KSA-KSB, Kantonsspital Aarau, Switzerland
| | - Stephan Bodis
- Centre for Radiation Oncology KSA-KSB, Kantonsspital Aarau, Switzerland; Department of Radiation Oncology, University Hospital Zurich, Switzerland
| |
Collapse
|
36
|
Cappiello G, Drizdal T, Mc Ginley B, O’Halloran M, Glavin M, van Rhoon GC, Jones E, Paulides MM. The potential of time-multiplexed steering in phased array microwave hyperthermia for head and neck cancer treatment. ACTA ACUST UNITED AC 2018; 63:135023. [DOI: 10.1088/1361-6560/aaca10] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
37
|
Verduijn GM, de Wee EM, Rijnen Z, Togni P, Hardillo JAU, Ten Hove I, Franckena M, van Rhoon GC, Paulides MM. Deep hyperthermia with the HYPERcollar system combined with irradiation for advanced head and neck carcinoma - a feasibility study. Int J Hyperthermia 2018; 34:994-1001. [PMID: 29747544 DOI: 10.1080/02656736.2018.1454610] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022] Open
Abstract
PURPOSE Radiotherapy (RT) treatment of locally-advanced and recurrent head and neck carcinoma (HNC) results in disappointing outcomes. Combination of RT with cisplatin or cetuximab improves survival but the increased toxicity and patient's comorbidity warrant the need for a less-toxic radiosensitizer. Stimulated by several randomized studies demonstrating the radio-sensitizing effect of hyperthermia, we developed the HYPERcollar. Here, we report early experience and toxicity in patients with advanced HNC. METHODS AND MATERIALS 119 hyperthermia treatments given to 27 patients were analyzed. Hyperthermia was applied once a week by the HYPERcollar aimed at achieving 39-43 °C in the target area, up to patients' tolerance. Pre-treatment planning was used to optimize treatment settings. When possible, invasive thermometry catheters were placed. RESULTS Mean power applied during the 119 hyperthermia treatments ranged from 120 to 1007 W (median 543 W). 15 (13%) hyperthermia treatments were not fully completed due to: pain allocated to hyperthermia (6/15), dyspnea from sticky saliva associated with irradiation (2/15) and unknown reasons (7/15). No severe complications or enhanced thermal or mucosal toxicities were observed. Excluding post-operative treatment, response rates after 3 months were 46% (complete) and 7% (partial). CONCLUSION Hyperthermia with the HYPERcollar proved to be safe and feasible with good compliance and promising outcome.
Collapse
Affiliation(s)
- G M Verduijn
- a Department of Radiation Oncology , Erasmus MC Cancer Institute , Rotterdam , Netherlands
| | - E M de Wee
- a Department of Radiation Oncology , Erasmus MC Cancer Institute , Rotterdam , Netherlands
| | - Z Rijnen
- a Department of Radiation Oncology , Erasmus MC Cancer Institute , Rotterdam , Netherlands
| | - P Togni
- a Department of Radiation Oncology , Erasmus MC Cancer Institute , Rotterdam , Netherlands
| | - J A U Hardillo
- b Department of Otorhinolaryngology-Head and neck surgery , Erasmus MC Cancer Institute , Rotterdam , Netherlands
| | - I Ten Hove
- c Department of Oral and Maxillofacial Surgery-Head and Neck Surgery , Erasmus MC Cancer Institute , Rotterdam , Netherlands
| | - M Franckena
- a Department of Radiation Oncology , Erasmus MC Cancer Institute , Rotterdam , Netherlands
| | - G C van Rhoon
- a Department of Radiation Oncology , Erasmus MC Cancer Institute , Rotterdam , Netherlands
| | - M M Paulides
- a Department of Radiation Oncology , Erasmus MC Cancer Institute , Rotterdam , Netherlands
| |
Collapse
|
38
|
Kok HP, Korshuize-van Straten L, Bakker A, de Kroon – Oldenhof R, Westerveld GH, Versteijne E, Stalpers LJA, Crezee J. Feasibility of on-line temperature-based hyperthermia treatment planning to improve tumour temperatures during locoregional hyperthermia. Int J Hyperthermia 2017; 34:1082-1091. [DOI: 10.1080/02656736.2017.1400120] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Affiliation(s)
- H. P. Kok
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - L. Korshuize-van Straten
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - A. Bakker
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - R. de Kroon – Oldenhof
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - G. H. Westerveld
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - E. Versteijne
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - L. J. A. Stalpers
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - J. Crezee
- Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
39
|
Drizdal T, Paulides MM, van Holthe N, van Rhoon GC. Hyperthermia treatment planning guided applicator selection for sub-superficial head and neck tumors heating. Int J Hyperthermia 2017; 34:704-713. [DOI: 10.1080/02656736.2017.1383517] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Affiliation(s)
- Tomas Drizdal
- Department of Radiation Oncology, Hyperthermia Unit, Erasmus MC Cancer Institute, Rotterdam, The Netherlands
| | - Margarethus M. Paulides
- Department of Radiation Oncology, Hyperthermia Unit, Erasmus MC Cancer Institute, Rotterdam, The Netherlands
| | - Netteke van Holthe
- Department of Radiation Oncology, Hyperthermia Unit, Erasmus MC Cancer Institute, Rotterdam, The Netherlands
| | - Gerard C. van Rhoon
- Department of Radiation Oncology, Hyperthermia Unit, Erasmus MC Cancer Institute, Rotterdam, The Netherlands
| |
Collapse
|
40
|
Cappiello G, McGinley B, Elahi MA, Drizdal T, Paulides MM, Glavin M, O'Halloran M, Jones E. Differential Evolution Optimization of the SAR Distribution for Head and Neck Hyperthermia. IEEE Trans Biomed Eng 2017; 64:1875-1885. [DOI: 10.1109/tbme.2016.2627941] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
41
|
Online Adaptive Hyperthermia Treatment Planning During Locoregional Heating to Suppress Treatment-Limiting Hot Spots. Int J Radiat Oncol Biol Phys 2017; 99:1039-1047. [PMID: 28870786 DOI: 10.1016/j.ijrobp.2017.07.011] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 07/05/2017] [Accepted: 07/10/2017] [Indexed: 01/20/2023]
Abstract
BACKGROUND Adequate tumor temperatures during hyperthermia are essential for good clinical response, but excessive heating of normal tissue should be avoided. This makes locoregional heating using phased array systems technically challenging. Online application of hyperthermia treatment planning could help to improve the heating quality. The aim of this study was to evaluate the clinical benefit of online treatment planning during treatment of pelvic tumors heated with the AMC-8 locoregional hyperthermia system. METHODS For online adaptive hyperthermia treatment planning, a graphical user interface was developed. Electric fields were calculated in a preprocessing step using our in-house-developed finite-difference-based treatment planning system. This allows instant calculation of the temperature distribution for user-selected phase-amplitude settings during treatment and projection onto the patient's computed tomographic scan for online visualization. Online treatment planning was used for 14 treatment sessions in 8 patients to reduce the patients' reports of hot spots while maintaining the same level of tumor heating. The predicted decrease in hot spot temperature should be at least 0.5°C, and the tumor temperature should decrease less than 0.2°C. These predictions were compared with clinical data: patient feedback about the hot spot and temperature measurements in the tumor region. RESULTS In total, 17 hot spot reports occurred during the 14 sessions, and the alternative settings predicted the hot spot temperature to decrease by at least 0.5°C, which was confirmed by the disappearance of all 17 hot spot reports. At the same time, the average tumor temperature was predicted to change on average -0.01°C (range, -0.19°C to 0.34°C). The measured tumor temperature change was on average only -0.02°C (range, -0.26°C to 0.31°C). In only 2 cases the temperature decrease was slightly larger than 0.2°C, but at most it was 0.26°C. CONCLUSIONS Online application of hyperthermia treatment planning is reliable and very useful to reduce hot spots without affecting tumor temperatures.
Collapse
|
42
|
Laser Ablation for Cancer: Past, Present and Future. J Funct Biomater 2017; 8:jfb8020019. [PMID: 28613248 PMCID: PMC5492000 DOI: 10.3390/jfb8020019] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Revised: 05/30/2017] [Accepted: 06/13/2017] [Indexed: 12/27/2022] Open
Abstract
Laser ablation (LA) is gaining acceptance for the treatment of tumors as an alternative to surgical resection. This paper reviews the use of lasers for ablative and surgical applications. Also reviewed are solutions aimed at improving LA outcomes: hyperthermal treatment planning tools and thermometric techniques during LA, used to guide the surgeon in the choice and adjustment of the optimal laser settings, and the potential use of nanoparticles to allow biologic selectivity of ablative treatments. Promising technical solutions and a better knowledge of laser-tissue interaction should allow LA to be used in a safe and effective manner as a cancer treatment.
Collapse
|
43
|
Kok HP, Kotte ANTJ, Crezee J. Planning, optimisation and evaluation of hyperthermia treatments. Int J Hyperthermia 2017; 33:593-607. [PMID: 28540779 DOI: 10.1080/02656736.2017.1295323] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND Hyperthermia treatment planning using dedicated simulations of power and temperature distributions is very useful to assist in hyperthermia applications. This paper describes an advanced treatment planning software package for a wide variety of applications. METHODS The in-house developed C++ software package Plan2Heat runs on a Linux operating system. Modules are available to perform electric field and temperature calculations for many heating techniques. The package also contains optimisation routines, post-treatment evaluation tools and a sophisticated thermal model enabling to account for 3D vasculature based on an angiogram or generated artificially using a vessel generation algorithm. The use of the software is illustrated by a simulation of a locoregional hyperthermia treatment for a pancreatic cancer patient and a spherical tumour model heated by interstitial hyperthermia, with detailed 3D vasculature included. RESULTS The module-based set-up makes the software flexible and easy to use. The first example demonstrates that treatment planning can help to focus the heating to the tumour. After optimisation, the simulated absorbed power in the tumour increased with 50%. The second example demonstrates the impact of accurately modelling discrete vasculature. Blood at body core temperature entering the heated volume causes relatively cold tracks in the heated volume, where the temperature remains below 40 °C. CONCLUSIONS A flexible software package for hyperthermia treatment planning has been developed, which can be very useful in many hyperthermia applications. The object-oriented structure of the source code allows relatively easy extension of the software package with additional tools when necessary for future applications.
Collapse
Affiliation(s)
- H P Kok
- a Department of Radiation Oncology , Academic Medical Center, University of Amsterdam , Amsterdam , The Netherlands
| | - A N T J Kotte
- b Department of Radiotherapy , University Medical Center Utrecht , Utrecht , The Netherlands
| | - J Crezee
- a Department of Radiation Oncology , Academic Medical Center, University of Amsterdam , Amsterdam , The Netherlands
| |
Collapse
|
44
|
Cuplov V, Pain F, Jan S. Simulation of nanoparticle-mediated near-infrared thermal therapy using GATE. BIOMEDICAL OPTICS EXPRESS 2017; 8:1665-1681. [PMID: 28663855 PMCID: PMC5480570 DOI: 10.1364/boe.8.001665] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Revised: 01/27/2017] [Accepted: 01/28/2017] [Indexed: 05/18/2023]
Abstract
Application of nanotechnology for biomedicine in cancer therapy allows for direct delivery of anticancer agents to tumors. An example of such therapies is the nanoparticle-mediated near-infrared hyperthermia treatment. In order to investigate the influence of nanoparticle properties on the spatial distribution of heat in the tumor and healthy tissues, accurate simulations are required. The Geant4 Application for Emission Tomography (GATE) open-source simulation platform, based on the Geant4 toolkit, is widely used by the research community involved in molecular imaging, radiotherapy and optical imaging. We present an extension of GATE that can model nanoparticle-mediated hyperthermal therapy as well as simple heat diffusion in biological tissues. This new feature of GATE combined with optical imaging allows for the simulation of a theranostic scenario in which the patient is injected with theranostic nanosystems that can simultaneously deliver therapeutic (i.e. hyperthermia therapy) and imaging agents (i.e. fluorescence imaging).
Collapse
Affiliation(s)
- Vesna Cuplov
- IMIV, CEA, Inserm, Université Paris Sud, CNRS, CEA/Service Hospitalier Frédéric Joliot, F-91401, Orsay,
France
| | - Frédéric Pain
- IMNC, CNRS, Université Paris Sud, Université Paris Saclay, F-91405, Orsay,
France
| | - Sébastien Jan
- IMIV, CEA, Inserm, Université Paris Sud, CNRS, CEA/Service Hospitalier Frédéric Joliot, F-91401, Orsay,
France
| |
Collapse
|
45
|
Paulides MM, Mestrom RMC, Salim G, Adela BB, Numan WCM, Drizdal T, Yeo DTB, Smolders AB. A printed Yagi-Uda antenna for application in magnetic resonance thermometry guided microwave hyperthermia applicators. Phys Med Biol 2017; 62:1831-1847. [PMID: 28052042 DOI: 10.1088/1361-6560/aa56b3] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Biological studies and clinical trials show that addition of hyperthermia stimulates conventional cancer treatment modalities and significantly improves treatment outcome. This supra-additive stimulation can be optimized by adaptive hyperthermia to counteract strong and dynamic thermoregulation. The only clinically proven method for the 3D non-invasive temperature monitoring required is by magnetic resonance (MR) temperature imaging, but the currently available set of MR compatible hyperthermia applicators lack the degree of heat control required. In this work, we present the design and validation of a high-frequency (433 MHz ISM band) printed circuit board antenna with a very low MR-footprint. This design is ideally suited for use in a range of hyperthermia applicator configurations. Experiments emulating the clinical situation show excellent matching properties of the antenna over a 7.2% bandwidth (S 11 < -15 dB). Its strongly directional radiation properties minimize inter-element coupling for typical array configurations (S 21 < -23 dB). MR imaging distortion by the antenna was found negligible and MR temperature imaging in a homogeneous muscle phantom was highly correlated with gold-standard probe measurements (root mean square error: RMSE = 0.51 °C and R 2 = 0.99). This work paves the way for tailored MR imaging guided hyperthermia devices ranging from single antenna or incoherent antenna-arrays, to real-time adaptive hyperthermia with phased-arrays.
Collapse
Affiliation(s)
- M M Paulides
- Department of Radiation Oncology, Erasmus University Medical Center, Cancer Institute, Rotterdam, Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
46
|
Schooneveldt G, Bakker A, Balidemaj E, Chopra R, Crezee J, Geijsen ED, Hartmann J, Hulshof MC, Kok HP, Paulides MM, Sousa-Escandon A, Stauffer PR, Maccarini PF. Thermal dosimetry for bladder hyperthermia treatment. An overview. Int J Hyperthermia 2016; 32:417-33. [DOI: 10.3109/02656736.2016.1156170] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
|
47
|
Paulides MM, Verduijn GM, Van Holthe N. Status quo and directions in deep head and neck hyperthermia. Radiat Oncol 2016; 11:21. [PMID: 26868027 PMCID: PMC4751675 DOI: 10.1186/s13014-016-0588-8] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2015] [Accepted: 01/13/2016] [Indexed: 12/18/2022] Open
Abstract
The benefit of hyperthermia as a potent modifier of radiotherapy has been well established and more recently also the combination with chemotherapy was shown beneficial. Also for head and neck cancer, the impact of hyperthermia has been clinically demonstrated by a number of clinical trials. Unfortunately, the technology applied in these studies provided only limited thermal dose control, and the devices used only allowed treatment of target regions close to the skin. Over the last decade, we developed the technology for deep and controlled hyperthermia that allows treatment of the entire head and neck region. Our strategy involves focused microwave heating combined with 3D patient-specific electromagnetic and thermal simulations for conformal, reproducible and adaptive hyperthermia application. Validation of our strategy has been performed by 3D thermal dose assessment based on invasively placed temperature sensors combined with the 3D patient specific simulations. In this paper, we review the phase III clinical evidence for hyperthermia in head and neck tumors, as well as the heating and dosimetry technology applied in these studies. Next, we describe the development, clinical implementation and validation of 3D guided deep hyperthermia with the HYPERcollar, and its second generation, i.e. the HYPERcollar3D. Lastly, we discuss early clinical results and provide an outlook for this technology.
Collapse
Affiliation(s)
| | - Gerda M Verduijn
- Erasmus MC Cancer Institute, Box 5201, 3008AE, Rotterdam, The Netherlands.
| | - Netteke Van Holthe
- Erasmus MC Cancer Institute, Box 5201, 3008AE, Rotterdam, The Netherlands.
| |
Collapse
|
48
|
Adibzadeh F, van Rhoon GC, Verduijn GM, Naus-Postema NC, Paulides MM. Absence of acute ocular damage in humans after prolonged exposure to intense RF EMF. Phys Med Biol 2015; 61:488-503. [PMID: 26682777 DOI: 10.1088/0031-9155/61/2/488] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The eye is considered to be a critical organ when determining safety standards for radio frequency (RF) radiation. Experimental data obtained using animals showed that RF heating of the eye, particularly over a specific threshold, can induce cataracts. During the treatment of cancer in the head and neck by hyperthermia, the eyes receive a considerable dose of RF radiation due to stray radiation from the prolonged (60 min) and intense exposure at 434 MHz of this region. In the current study, we verified the exposure guidelines for humans by determining the association between the electromagnetic and thermal dose in the eyes with the reported ocular effects. We performed a simulation study to retrospectively assess the specific absorption rate (SAR) and temperature increase in the eyes of 16 selected patients (encompassing a total of 74 treatment sessions) whose treatment involved high power delivery as well as a minimal distance between the tumor site and the eye. Our results show that the basic restrictions on the peak 10 g spatial-averaged SAR (10 W kg(-1)) and peak tissue temperature increase (1 °C) are exceeded by up to 10.4 and 4.6 times, on average, and by at least 6.2 and 1.8 times when considering the lower limit of the 95% confidence interval. Evaluation of the acute effects according to patients' feedback (all patients), the common toxicity criteria scores (all patients) and an ophthalmology investigation (one patient with the highest exposure) revealed no indication of any serious acute ocular effect, even though the eyes were exposed to high electromagnetic fields, leading to a high thermal dose. We also found that, although there is a strong correlation (R (2) = 0.88) between the predicted induced SAR and temperature in the eye, there are large uncertainties regarding the temperature-SAR relationship. Given this large uncertainty (129%) compared with the uncertainty of 3D temperature simulations (61%), we recommend using temperature simulations as a dosimetric measure in electromagnetic exposure risk assessments.
Collapse
Affiliation(s)
- F Adibzadeh
- Department of Radiation Oncology, Erasmus MC: Daniel den Hoed Cancer Center, Hyperthermia Unit, 3015 CE Rotterdam, The Netherlands
| | | | | | | | | |
Collapse
|
49
|
Crezee H, van Leeuwen CM, Oei AL, Stalpers LJA, Bel A, Franken NA, Kok HP. Thermoradiotherapy planning: Integration in routine clinical practice. Int J Hyperthermia 2015; 32:41-9. [PMID: 26670625 DOI: 10.3109/02656736.2015.1110757] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Planning of combined radiotherapy and hyperthermia treatments should be performed taking the synergistic action between the two modalities into account. This work evaluates the available experimental data on cytotoxicity of combined radiotherapy and hyperthermia treatment and the requirements for integration of hyperthermia and radiotherapy treatment planning into a single planning platform. The underlying synergistic mechanisms of hyperthermia include inhibiting DNA repair, selective killing of radioresistant hypoxic tumour tissue and increased radiosensitivity by enhanced tissue perfusion. Each of these mechanisms displays different dose-effect relations, different optimal time intervals and different optimal sequences between radiotherapy and hyperthermia. Radiosensitisation can be modelled using the linear-quadratic (LQ) model to account for DNA repair inhibition by hyperthermia. In a recent study, an LQ model-based thermoradiotherapy planning (TRTP) system was used to demonstrate that dose escalation by hyperthermia is equivalent to ∼10 Gy for prostate cancer patients treated with radiotherapy. The first step for more reliable TRTP is further expansion of the data set of LQ parameters for normally oxygenated normal and tumour tissue valid over the temperature range used clinically and for the relevant time intervals between radiotherapy and hyperthermia. The next step is to model the effect of hyperthermia in hypoxic tumour cells including the physiological response to hyperthermia and the resulting reoxygenation. Thermoradiotherapy planning is feasible and a necessity for an optimal clinical application of hyperthermia combined with radiotherapy in individual patients.
Collapse
Affiliation(s)
- Hans Crezee
- a Department of Radiation Oncology , Academic Medical Centre , Amsterdam and
| | | | - Arlene L Oei
- a Department of Radiation Oncology , Academic Medical Centre , Amsterdam and.,b Laboratory for Experimental Oncology and Radiobiology , Academic Medical Centre , Amsterdam , The Netherlands
| | - Lukas J A Stalpers
- a Department of Radiation Oncology , Academic Medical Centre , Amsterdam and
| | - Arjan Bel
- a Department of Radiation Oncology , Academic Medical Centre , Amsterdam and
| | - Nicolaas A Franken
- a Department of Radiation Oncology , Academic Medical Centre , Amsterdam and.,b Laboratory for Experimental Oncology and Radiobiology , Academic Medical Centre , Amsterdam , The Netherlands
| | - H Petra Kok
- a Department of Radiation Oncology , Academic Medical Centre , Amsterdam and
| |
Collapse
|
50
|
Datta NR, Rogers S, Ordóñez SG, Puric E, Bodis S. Hyperthermia and radiotherapy in the management of head and neck cancers: A systematic review and meta-analysis. Int J Hyperthermia 2015; 32:31-40. [PMID: 26928474 DOI: 10.3109/02656736.2015.1099746] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
PURPOSE A systematic review and meta-analysis was conducted to evaluate the outcome of controlled clinical trials in head and neck cancers (HNCs) using hyperthermia and radiotherapy versus radiotherapy alone. MATERIAL AND METHODS A total of 498 abstracts were screened from four databases and hand searched as per the PRISMA guidelines. Only two-arm studies treating HNCs with either radiotherapy alone, or hyperthermia and radiotherapy without concurrent chemotherapy or surgery were considered. The evaluated end point was complete response (CR). RESULTS Following a detailed screening of the titles, abstracts and full text papers, six articles fulfilling the above eligibility criteria were considered. In total 451 clinical cases from six studies were included in the meta-analysis. Five of six trials were randomised. The overall CR with radiotherapy alone was 39.6% (92/232) and varied between 31.3% and 46.9% across the six trials. With thermoradiotherapy, the overall CR reported was 62.5% (137/219), (range 33.9-83.3%). The odds ratio was 2.92 (95% CI: 1.58-5.42, p = 0.001); the risk ratio was 1.61 (95% CI: 1.32-1.97, p < 0.0001) and the risk difference was 0.25 (95% CI: 0.12-0.39, p < 0.0001), all in favour of combined treatment with hyperthermia and radiotherapy over radiotherapy alone. Acute and late grade III/IV toxicities were reported to be similar in both the groups. CONCLUSIONS Hyperthermia along with radiotherapy enhances the likelihood of CR in HNCs by around 25% compared to radiotherapy alone with no significant additional acute and late morbidities. This level I evidence should justify the integration of hyperthermia into the multimodality therapy of HNCs.
Collapse
Affiliation(s)
- Niloy R Datta
- a Centre for Radiation Oncology , KSA-KSB, Kantonsspital , Aarau , Switzerland and
| | - Susanne Rogers
- a Centre for Radiation Oncology , KSA-KSB, Kantonsspital , Aarau , Switzerland and
| | - Silvia Gómez Ordóñez
- a Centre for Radiation Oncology , KSA-KSB, Kantonsspital , Aarau , Switzerland and
| | - Emsad Puric
- a Centre for Radiation Oncology , KSA-KSB, Kantonsspital , Aarau , Switzerland and
| | - Stephan Bodis
- a Centre for Radiation Oncology , KSA-KSB, Kantonsspital , Aarau , Switzerland and.,b Department of Radiation Oncology , University Hospital , Zurich , Switzerland
| |
Collapse
|