1
|
Chainani PH, Buzo Mena M, Yeritsyan D, Caro D, Momenzadeh K, Galloway JL, DeAngelis JP, Ramappa AJ, Nazarian A. Successive tendon injury in an in vivo rat overload model induces early damage and acute healing responses. Front Bioeng Biotechnol 2024; 12:1327094. [PMID: 38515627 PMCID: PMC10955762 DOI: 10.3389/fbioe.2024.1327094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 01/16/2024] [Indexed: 03/23/2024] Open
Abstract
Introduction: Tendinopathy is a degenerative condition resulting from tendons experiencing abnormal levels of multi-scale damage over time, impairing their ability to repair. However, the damage markers associated with the initiation of tendinopathy are poorly understood, as the disease is largely characterized by end-stage clinical phenotypes. Thus, this study aimed to evaluate the acute tendon responses to successive fatigue bouts of tendon overload using an in vivo passive ankle dorsiflexion system. Methods: Sprague Dawley female rats underwent fatigue overloading to their Achilles tendons for 1, 2, or 3 loading bouts, with two days of rest in between each bout. Mechanical, structural, and biological assays were performed on tendon samples to evaluate the innate acute healing response to overload injuries. Results: Here, we show that fatigue overloading significantly reduces in vivo functional and mechanical properties, with reductions in hysteresis, peak stress, and loading and unloading moduli. Multi-scale structural damage on cellular, fibril, and fiber levels demonstrated accumulated micro-damage that may have induced a reparative response to successive loading bouts. The acute healing response resulted in alterations in matrix turnover and early inflammatory upregulations associated with matrix remodeling and acute responses to injuries. Discussion: This work demonstrates accumulated damage and acute changes to the tendon healing response caused by successive bouts of in vivo fatigue overloads. These results provide the avenue for future investigations of long-term evaluations of tendon overload in the context of tendinopathy.
Collapse
Affiliation(s)
- Pooja H. Chainani
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
- Department of Mechanical Engineering, Boston University, Boston, MA, United States
| | - Maria Buzo Mena
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
| | - Diana Yeritsyan
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
| | - Daniela Caro
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
| | - Kaveh Momenzadeh
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
| | - Jenna L. Galloway
- Center for Regenerative Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
| | - Joseph P. DeAngelis
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
- Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
| | - Arun J. Ramappa
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
- Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
| | - Ara Nazarian
- Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
- Department of Mechanical Engineering, Boston University, Boston, MA, United States
- Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States
- Department of Orthopaedic Surgery, Yerevan State Medical University, Yerevan, Armenia
| |
Collapse
|
2
|
Gundogdu K, Yilmaz Tasci S, Gundogdu G, Terim Kapakin KA, Totik Y, Demirkaya Miloglu F. Evaluation of cytokines in protective effect of docosahexaenoic acid in experimental achilles tendinopathy rat model induced with type-1 collagenase. Connect Tissue Res 2022; 63:393-405. [PMID: 34612118 DOI: 10.1080/03008207.2021.1982915] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND We aimed to investigate the effectiveness of docosahexaenoic acid (DHA) as a treatment for Achilles tendinopathy (AT) induced with type-I collagenase in rats and compare it with collagen. METHODS The AT model was induced with type I collagenase, and animals were randomly assigned to groups. Group 1:AT, Group 2: Collagen (7.2 mg/kg/day), Group 3:DHA (300 mg/kg/day), and Group 4:DHA (100 mg/kg/day). Right tendons of Group1 were used as a healthy control (HC). Oral treatments were applied for eight weeks. Serum tumor necrosis factor-alpha(TNF-α), matrix metalloproteinase-13 (MMP-13), and interleukin-1 beta(IL-1β) concentrations were determined by ELISA. Tendon samples were taken for histopathological evaluation and examined immunohistochemically with antibodies specific for Col1A1, TNF-α, MMP-13, IL-1β, and nitric oxide synthase-2(NOS-2). The ultimate tensile force (UTF) yield force(YF) and stiffness were measured by biomechanical assessments. RESULTS UTF,YF and stiffness values were increased in all treatment groups compared to the AT control, a significant increase was found in Group 2 (p < 0.05). There was severe degeneration of tendon cells in the AT control. The tendon cells in samples from Groups 2-3 were less degraded, and this was statistically significant (p < 0.05). TNF-α, MMP-13, IL-1β, and NOS-2 expressions were significantly higher in the AT control compared to the HC. In all treatment groups, their concentrations were lower than in the AT control. Serum TNF-α, MMP-13, and IL-1β levels were lower in all treatment groups (Especially in Group3 (p < 0.001)) compared to Group1. CONCLUSION The efficacy of high-dose DHA as a treatment for AT was investigated from biochemical, histopathological, and biomechanical perspectives. The results showed that DHA could be an alternative treatment compound to collagen.
Collapse
Affiliation(s)
- Koksal Gundogdu
- Department of Orthopedics and Traumatology, Denizli State Hospital, Denizli, Turkey
| | | | - Gulsah Gundogdu
- Department of Physiology, Faculty of Medicine, Pamukkale University, Denizli, Turkey
| | - Kubra Asena Terim Kapakin
- Department of Veterinary Pathology, Faculty of Veterinary Medicine, Ataturk University, Erzurum, Turkey
| | - Yasar Totik
- Department of Machine Engineering, Faculty of Engineering, Ataturk University, Erzurum, Turkey
| | - Fatma Demirkaya Miloglu
- Department of Analytical Chemistry, Faculty of Pharmacy, Ataturk University, Erzurum, Turkey
| |
Collapse
|
3
|
Williamson PM, Freedman BR, Kwok N, Beeram I, Pennings J, Johnson J, Hamparian D, Cohen E, Galloway JL, Ramappa AJ, DeAngelis JP, Nazarian A. Tendinopathy and tendon material response to load: What we can learn from small animal studies. Acta Biomater 2021; 134:43-56. [PMID: 34325074 DOI: 10.1016/j.actbio.2021.07.046] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 07/16/2021] [Accepted: 07/21/2021] [Indexed: 12/20/2022]
Abstract
Tendinopathy is a debilitating disease that causes as much as 30% of all musculoskeletal consultations. Existing treatments for tendinopathy have variable efficacy, possibly due to incomplete characterization of the underlying pathophysiology. Mechanical load can have both beneficial and detrimental effects on tendon, as the overall tendon response depends on the degree, frequency, timing, and magnitude of the load. The clinical continuum model of tendinopathy offers insight into the late stages of tendinopathy, but it does not capture the subclinical tendinopathic changes that begin before pain or loss of function. Small animal models that use high tendon loading to mimic human tendinopathy may be able to fill this knowledge gap. The goal of this review is to summarize the insights from in-vivo animal studies of mechanically-induced tendinopathy and higher loading regimens into the mechanical, microstructural, and biological features that help characterize the continuum between normal tendon and tendinopathy. STATEMENT OF SIGNIFICANCE: This review summarizes the insights gained from in-vivo animal studies of mechanically-induced tendinopathy by evaluating the effect high loading regimens have on the mechanical, structural, and biological features of tendinopathy. A better understanding of the interplay between these realms could lead to improved patient management, especially in the presence of painful tendon.
Collapse
|
4
|
Lu V, Tennyson M, Zhang J, Khan W. Mesenchymal Stem Cell-Derived Extracellular Vesicles in Tendon and Ligament Repair-A Systematic Review of In Vivo Studies. Cells 2021; 10:cells10102553. [PMID: 34685532 PMCID: PMC8533909 DOI: 10.3390/cells10102553] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 09/18/2021] [Accepted: 09/22/2021] [Indexed: 12/23/2022] Open
Abstract
Tendon and ligament injury poses an increasingly large burden to society. This systematic review explores whether mesenchymal stem cell-derived extracellular vesicles (MSC-EVs) can facilitate tendon/ligament repair in vivo. On 26 May 2021, a systematic search was performed on PubMed, Web of Science, Cochrane Library, Embase, to identify all studies that utilised MSC-EVs for tendon/ligament healing. Studies administering EVs isolated from human or animal-derived MSCs into in vivo models of tendon/ligament injury were included. In vitro, ex vivo, and in silico studies were excluded, and studies without a control group were excluded. Out of 383 studies identified, 11 met the inclusion criteria. Data on isolation, the characterisation of MSCs and EVs, and the in vivo findings in in vivo models were extracted. All included studies reported better tendon/ligament repair following MSC-EV treatment, but not all found improvements in every parameter measured. Biomechanics, an important index for tendon/ligament repair, was reported by only eight studies, from which evidence linking biomechanical alterations to functional improvement was weak. Nevertheless, the studies in this review showcased the safety and efficacy of MSC-EV therapy for tendon/ligament healing, by attenuating the initial inflammatory response and accelerating tendon matrix regeneration, providing a basis for potential clinical use in tendon/ligament repair.
Collapse
Affiliation(s)
- Victor Lu
- School of Clinical Medicine, University of Cambridge, Cambridge CB2 0SP, UK; (V.L.); (J.Z.)
| | - Maria Tennyson
- Department of Trauma and Orthopaedic Surgery, Addenbrooke’s Hospital, University of Cambridge, Cambridge CB2 0QQ, UK;
| | - James Zhang
- School of Clinical Medicine, University of Cambridge, Cambridge CB2 0SP, UK; (V.L.); (J.Z.)
| | - Wasim Khan
- Department of Trauma and Orthopaedic Surgery, Addenbrooke’s Hospital, University of Cambridge, Cambridge CB2 0QQ, UK;
- Correspondence: ; Tel.: +44-(0)-7791-025554
| |
Collapse
|
5
|
Couppé C, Svensson RB, Skovlund SV, Jensen JK, Eriksen CS, Malmgaard-Clausen NM, Nybing JD, Kjaer M, Magnusson SP. Habitual side-specific loading leads to structural, mechanical and compositional changes in the patellar tendon of young and senior life-long male athletes. J Appl Physiol (1985) 2021; 131:1187-1199. [PMID: 34382838 DOI: 10.1152/japplphysiol.00202.2021] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Effects of life-long physical activity on tendon function have been investigated in cross-sectional studies, but these are at risk of "survivorship" bias. Here, we investigate if life-long side-specific loading is associated with greater cross-sectional area (CSA), mechanical properties, cell density (DNA content) and collagen cross-link composition of the male human patellar tendon (PT), in vivo. Nine seniors and six young male life-long elite badminton players and fencers were included. CSA of the PT obtained by 3-tesla MRI, and ultrasonography-based bilateral PT mechanics were assessed. Collagen fibril characteristics, enzymatic cross-links, non-enzymatic glycation (autofluorescence), collagen and DNA content were measured biochemically in PT biopsies. The elite athletes had a ≥15% side-to-side difference in maximal knee extensor strength, reflecting chronic unilateral sport-specific loading patterns. The PT CSA was greater on the lead extremity compared with the non-lead extremity (17 %, p=0.0001). Furthermore, greater tendon stiffness (18 %, p=0.0404) together with lower tendon stress (22 %, p=0.0005) and tendon strain (18 %, p=0.0433) were observed on the lead extremity. No effects were demonstrated from side-to-side for glycation, enzymatic cross-link, collagen, and DNA content (50%, p=0.1160). Moreover, tendon fibril density was 87±28 fibrils/μm2 on the lead extremity and 68±26 fibrils/μm2 on the non-lead extremity (28%, p=0.0544). Tendon fibril diameter was 86±14 nm on the lead extremity and 94±14 nm on the non-lead extremity (-9%, p=0.1076). These novel data suggest that life-long side-specific loading in males yields greater patellar tendon size and stiffness possibly with concomitant greater fibril density but without changes of collagen cross-link composition.
Collapse
Affiliation(s)
- Christian Couppé
- Institute of Sports Medicine Copenhagen, Bispebjerg-Frederiksberg Hospitals, Denmark.,Department of Physical and Occupational Therapy, Bispebjerg-Frederiksberg Hospitals, Denmark
| | - Rene B Svensson
- Institute of Sports Medicine Copenhagen, Bispebjerg-Frederiksberg Hospitals, Denmark
| | - Sebastian V Skovlund
- Institute of Sports Medicine Copenhagen, Bispebjerg-Frederiksberg Hospitals, Denmark.,Department of Physical and Occupational Therapy, Bispebjerg-Frederiksberg Hospitals, Denmark
| | | | | | | | - Janus Damm Nybing
- Department of Radiology, Bispebjerg-Frederiksberg Hospitals, Denmark
| | - Michael Kjaer
- Institute of Sports Medicine Copenhagen, Bispebjerg-Frederiksberg Hospitals, Denmark
| | - S Peter Magnusson
- Institute of Sports Medicine Copenhagen, Bispebjerg-Frederiksberg Hospitals, Denmark.,Department of Physical and Occupational Therapy, Bispebjerg-Frederiksberg Hospitals, Denmark
| |
Collapse
|
6
|
Nie D, Zhou Y, Wang W, Zhang J, Wang JHC. Mechanical Overloading Induced-Activation of mTOR Signaling in Tendon Stem/Progenitor Cells Contributes to Tendinopathy Development. Front Cell Dev Biol 2021; 9:687856. [PMID: 34322484 PMCID: PMC8311934 DOI: 10.3389/fcell.2021.687856] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 06/18/2021] [Indexed: 01/08/2023] Open
Abstract
Despite the importance of mechanical loading in tendon homeostasis and pathophysiology, the molecular responses involved in the mechanotransduction in tendon cells remain unclear. In this study, we found that in vitro mechanical loading activated the mammalian target of rapamycin (mTOR) in rat patellar tendon stem/progenitor cells (TSCs) in a stretching magnitude-dependent manner. Application of rapamycin, a specific inhibitor of mTOR, attenuated the phosphorylation of S6 and 4E-BP1 and as such, largely inhibited the mechanical activation of mTOR. Moreover, rapamycin significantly decreased the proliferation and non-tenocyte differentiation of PTSCs as indicated by the reduced expression levels of LPL, PPARγ, SOX-9, collagen II, Runx-2, and osteocalcin genes. In the animal studies, mice subjected to intensive treadmill running (ITR) developed tendon degeneration, as evidenced by the formation of round-shaped cells, accumulation of proteoglycans, and expression of SOX-9 and collagen II proteins. However, daily injections of rapamycin in ITR mice reduced all these tendon degenerative changes. Collectively, these findings suggest that mechanical loading activates the mTOR signaling in TSCs, and rapamycin may be used to prevent tendinopathy development by blocking non-tenocyte differentiation due to mechanical over-activation of mTOR in TSCs.
Collapse
Affiliation(s)
- Daibang Nie
- Department of Immunology, College of Basic Medicine, Chongqing Medical University, Chongqing, China
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, United States
| | - Yiqin Zhou
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, United States
- Department of Orthopaedics, Shanghai Changzheng Hospital, Naval Medical University, Shanghai, China
| | - Wang Wang
- Department of Immunology, College of Basic Medicine, Chongqing Medical University, Chongqing, China
| | - Jianying Zhang
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, United States
| | - James H.-C. Wang
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, United States
- Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, United States
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
| |
Collapse
|
7
|
Liu Y, Hao L, Jiang L, Li H. Therapeutic effect of pulsed electromagnetic field on bone wound healing in rats. Electromagn Biol Med 2020; 40:26-32. [PMID: 33251878 DOI: 10.1080/15368378.2020.1851252] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
This study aimed to investigate the therapeutic effect of pulsed electromagnetic field (PEMF) on bone wound in rats as a potential therapy for bone fracture-related conditions. Male rats, aged 3 months, were used to construct model of bone wounding. Wound models were randomly selected to receive PEMF therapy at 1 to 10 mT intensity. Models that did not receive PEMF therapy were used as control. The serum concentrations of calcium (Ca), phosphorus (P) and alkaline phosphatase (ALP) were determined. Bone density and biomechanical properties of callus were measured using a tensile tester. Compared with control, rats subjected to PEMF therapy had similar weight gain, but significantly higher levels of serum Ca and ALP (P < .05) at 5 and 10 mT, while the serum level of P remained unchanged after PEMF therapy. The bone mineral density of callus increased after the therapy, particularly, after 5 and 10 mT therapy (P < .05). Biomechanical measurements showed that 21 days after the therapy, the maximum load, fracture load, elastic load and bending energy were significantly greater in rats receiving 5 and 10 mT PEMF therapy as compared with control (P < .05). Our experiments demonstrate that PEMF at 5 and 10 mT can significantly accelerate wound healing and enhance the repairing ability of bone tissue.
Collapse
Affiliation(s)
- Yingxin Liu
- Department of Hand and Foot Surgery, Yidu Central Hospital , Weifang, China
| | - Lijuan Hao
- Department of Urology, Yidu Central Hospital , Weifang, China
| | - Liyan Jiang
- Department of Hand and Foot Surgery, Yidu Central Hospital , Weifang, China
| | - Haitao Li
- Department of Surgery, Yidu Central Hospital , Weifang, China
| |
Collapse
|
8
|
Abstract
Tendons link muscle to bone and transfer forces necessary for normal movement. Tendon injuries can be debilitating and their intrinsic healing potential is limited. These challenges have motivated the development of model systems to study the factors that regulate tendon formation and tendon injury. Recent advances in understanding of embryonic and postnatal tendon formation have inspired approaches that aimed to mimic key aspects of tendon development. Model systems have also been developed to explore factors that regulate tendon injury and healing. We highlight current model systems that explore developmentally inspired cellular, mechanical, and biochemical factors in tendon formation and tenogenic stem cell differentiation. Next, we discuss in vivo, in vitro, ex vivo, and computational models of tendon injury that examine how mechanical loading and biochemical factors contribute to tendon pathologies and healing. These tendon development and injury models show promise for identifying the factors guiding tendon formation and tendon pathologies, and will ultimately improve regenerative tissue engineering strategies and clinical outcomes.
Collapse
Affiliation(s)
- Sophia K Theodossiou
- Biological Engineering, University of Idaho, 875 Perimeter Dr. MS 0904, Moscow, ID 83844, USA
| | - Nathan R Schiele
- Biological Engineering, University of Idaho, 875 Perimeter Dr. MS 0904, Moscow, ID 83844, USA
| |
Collapse
|
9
|
Lin X, Huang M, Yin G, Zhang J, Zhang Z, Lai P, Yan B, Chen Y, Jin D, Wang L. Characterization of a Novel Calcific Achilles Tendinopathy Model in Mice: Contralateral Tendinopathy Induced by Unilateral Tenotomy. Calcif Tissue Int 2018; 103:698-707. [PMID: 30132146 DOI: 10.1007/s00223-018-0465-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Accepted: 08/08/2018] [Indexed: 01/14/2023]
Abstract
Achilles tendinopathy is a significant clinical disease characterized by activity-related pain, focal movement limitation, and intratendinous imaging changes. However, treatment of Achilles tendinopathy has been based mainly on theoretical rationale and clinical experience because of its unclear underlying pathogenesis and mechanism. The purpose of the study was to develop a simple but reproducible overuse-induced animal model of Achilles tendinopathy in mice to better understand the underlying mechanism and prevent calcific Achilles tendinopathy. A total of 80 C57/B6 mice (8 or 9 weeks old) were employed and randomly divided into control and experimental groups. Unilateral Achilles tenotomy was performed on the right hind limbs in the experiment group. 12 weeks after unilateral Achilles tenotomy, the onset of Achilles tendinopathy in the contralateral Achilles tendon was determined by radiological assessment, histologic analysis, electron microscopy observation, and biomechanical test. The onset of calcific Achilles tendinopathy in contralateral Achilles tendon was confirmed after 12 weeks of unilateral tenotomy. The contralateral Achilles tendon in the experimental group was characterized as hypercellularity, neovascularization, and fused collagen fiber disarrangement, compared with the control group. Importantly, intra-tendon endochondral ossification and calcaneus deformity were featured in contralateral Achilles tendon. In addition, poor biomechanical properties in the contralateral Achilles tendon revealed the incidence of Achilles tendinopathy. We hereby introduce a novel, simple, but reproducible spontaneous contralateral calcific Achilles tendinopathy model in mice, which represents overuse conditions during tendinopathy development in humans. It should be a useful tool to further study the underlying pathogenesis of calcific Achilles tendinopathy.
Collapse
Affiliation(s)
- Xuemei Lin
- Department of Orthopaedics, The Third Affiliated Hospital of Southern Medical University, 183 West Zhongshan Avenue, Guangzhou, 510665, Guangdong, People's Republic of China
- Academy of Orthopaedics, Guangdong Province, Guangzhou, 510665, Guangdong, People's Republic of China
| | - Minjun Huang
- Department of Orthopaedics, The Third Affiliated Hospital of Southern Medical University, 183 West Zhongshan Avenue, Guangzhou, 510665, Guangdong, People's Republic of China
- Academy of Orthopaedics, Guangdong Province, Guangzhou, 510665, Guangdong, People's Republic of China
| | - Ganghui Yin
- Department of Orthopaedics, The Third Affiliated Hospital of Southern Medical University, 183 West Zhongshan Avenue, Guangzhou, 510665, Guangdong, People's Republic of China
- Academy of Orthopaedics, Guangdong Province, Guangzhou, 510665, Guangdong, People's Republic of China
| | - Jie Zhang
- Department of Orthopaedics, The Third Affiliated Hospital of Southern Medical University, 183 West Zhongshan Avenue, Guangzhou, 510665, Guangdong, People's Republic of China
- Academy of Orthopaedics, Guangdong Province, Guangzhou, 510665, Guangdong, People's Republic of China
| | - Zhongmin Zhang
- Department of Orthopaedics, The Third Affiliated Hospital of Southern Medical University, 183 West Zhongshan Avenue, Guangzhou, 510665, Guangdong, People's Republic of China
- Academy of Orthopaedics, Guangdong Province, Guangzhou, 510665, Guangdong, People's Republic of China
| | - Pinglin Lai
- Department of Orthopaedics, The Third Affiliated Hospital of Southern Medical University, 183 West Zhongshan Avenue, Guangzhou, 510665, Guangdong, People's Republic of China
- Academy of Orthopaedics, Guangdong Province, Guangzhou, 510665, Guangdong, People's Republic of China
| | - Bo Yan
- Department of Orthopaedics, The Third Affiliated Hospital of Southern Medical University, 183 West Zhongshan Avenue, Guangzhou, 510665, Guangdong, People's Republic of China
- Academy of Orthopaedics, Guangdong Province, Guangzhou, 510665, Guangdong, People's Republic of China
| | - Yuhui Chen
- Department of Orthopaedics, The Third Affiliated Hospital of Southern Medical University, 183 West Zhongshan Avenue, Guangzhou, 510665, Guangdong, People's Republic of China
- Academy of Orthopaedics, Guangdong Province, Guangzhou, 510665, Guangdong, People's Republic of China
| | - Dadi Jin
- Department of Orthopaedics, The Third Affiliated Hospital of Southern Medical University, 183 West Zhongshan Avenue, Guangzhou, 510665, Guangdong, People's Republic of China.
- Academy of Orthopaedics, Guangdong Province, Guangzhou, 510665, Guangdong, People's Republic of China.
| | - Liang Wang
- Department of Orthopaedics, The Third Affiliated Hospital of Southern Medical University, 183 West Zhongshan Avenue, Guangzhou, 510665, Guangdong, People's Republic of China.
- Academy of Orthopaedics, Guangdong Province, Guangzhou, 510665, Guangdong, People's Republic of China.
| |
Collapse
|
10
|
Thampatty BP, Wang JHC. Mechanobiology of young and aging tendons: In vivo studies with treadmill running. J Orthop Res 2018; 36:557-565. [PMID: 28976604 PMCID: PMC5839954 DOI: 10.1002/jor.23761] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Accepted: 09/13/2017] [Indexed: 02/04/2023]
Abstract
Tendons are unique in the sense that they are constantly subjected to large mechanical loads and that they contain tendon-specific cells, including tenocytes and tendon stem/progenitor cells. The responses of these cells to mechanical loads can be anabolic or catabolic and as a result, change the biological properties of the tendon itself that may be beneficial or detrimental. On the other hand, aging also induces aberrant changes in cellular expression of various genes and production of various types of matrix proteins in the tendon, and consequently lead to tendon degeneration and impaired healing in aging tendons; both could be improved by moderate physiological mechanical loading such as treadmill running. This article gives an overview on the mechanobiology research of young and aging animal tendons using treadmill running model. The challenges in such treadmill running studies are also discussed. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:557-565, 2018.
Collapse
Affiliation(s)
- Bhavani P. Thampatty
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, 210 Lothrop street, BST, E1640, Pittsburgh, PA 15213, USA
| | - James H-C. Wang
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, 210 Lothrop street, BST, E1640, Pittsburgh, PA 15213, USA
| |
Collapse
|
11
|
Choi HMC, Cheing AKK, Ng GYF, Cheing GLY. Effects of pulsed electromagnetic field (PEMF) on the tensile biomechanical properties of diabetic wounds at different phases of healing. PLoS One 2018; 13:e0191074. [PMID: 29324868 PMCID: PMC5764361 DOI: 10.1371/journal.pone.0191074] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Accepted: 12/26/2017] [Indexed: 12/30/2022] Open
Abstract
The present study investigated the effects of pulsed electromagnetic field (PEMF) on the tensile biomechanical properties of diabetic wounds at different phases of healing. Two intensities of PEMF were adopted for comparison. We randomly assigned 111 10-week-old male streptozotocin-induced diabetic Sprague-Dawley rats to two PEMF groups and a sham control group. Six-millimetre biopsy punched full thickness wounds were made on the lateral side of their hindlimbs. The PEMF groups received active PEMF delivered at 25 Hz with intensity of either 2 mT or 10 mT daily, while the sham group was handled in a similar way except they were not exposed to PEMF. Wound tissues were harvested for tensile testing on post-wounding days 3, 5, 7, 10, 14 and 21. Maximum load, maximum stress, energy absorption capacity, Young’s modulus and thickness of wound tissue were measured. On post-wounding day 5, the PEMF group that received 10-mT intensity had significantly increased energy absorption capacity and showed an apparent increase in the maximum load. However, the 10-mT PEMF group demonstrated a decrease in Young’s modulus on day 14. The 10-mT PEMF groups showed a significant increase in the overall thickness of wound tissue whereas the 2-mT group showed a significant decrease in the overall maximum stress of the wounds tissue. The present findings demonstrated that the PEMF delivered at 10 mT can improve energy absorption capacity of diabetic wounds in the early healing phase. However, PEMF (both 2-mT and 10-mT) seemed to impair the material properties (maximum stress and Young’s modulus) in the remodelling phase. PEMF may be a useful treatment for promoting the recovery of structural properties (maximum load and energy absorption capacity), but it might not be applied at the remodelling phase to avoid impairing the recovery of material properties.
Collapse
Affiliation(s)
- Harry M. C. Choi
- Department of Rehabilitation Sciences, Faculty of Health and Social Sciences, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | - Alex K. K. Cheing
- Department of Rehabilitation Sciences, Faculty of Health and Social Sciences, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | - Gabriel Y. F. Ng
- Department of Rehabilitation Sciences, Faculty of Health and Social Sciences, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | - Gladys L. Y. Cheing
- Department of Rehabilitation Sciences, Faculty of Health and Social Sciences, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
- * E-mail:
| |
Collapse
|
12
|
Lee SY, Chieh HF, Lin CJ, Jou IM, Sun YN, Kuo LC, Wu PT, Su FC. Characteristics of Sonography in a Rat Achilles Tendinopathy Model: Possible Non-invasive Predictors of Biomechanics. Sci Rep 2017; 7:5100. [PMID: 28698601 PMCID: PMC5506063 DOI: 10.1038/s41598-017-05466-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Accepted: 05/31/2017] [Indexed: 12/21/2022] Open
Abstract
The purpose of this study was to investigate the dynamic changes of histopathology, biomechanical properties, echo intensity, and ultrasound features in a collagenase-induced tendinopathy model of rat Achilles tendons, and to examine the associations among biomechanical properties, echo intensity, and ultrasound features. Forty-two rats received an ultrasound-guided collagenase injection on their left Achilles tendons, and needle puncture on the right ones as the control. At four, eight, and twelve weeks post-injury, the tendons were examined via measurements of their biomechanical properties, histopathological and ultrasonographic characteristics. The injured tendons showed significantly higher histopathological scores, lower Young’s modulus, and higher ultrasound feature scores than the those of control ones throughout the study period. Up to week 12, all injured tendons showed defective healing. The neovascularization score had a significant negative linear association with the failure stress and Young’s modulus. Maximum normalized echo intensity had a significant positive linear association with maximum strain. Therefore, neovascularization and maximum normalized echo intensity are associated with mechanically altered tendinopathic tendons. Non-invasive ultrasound methodology, including echo intensity and ultrasound feature scores, may provide useful information about biomechanical properties of tendinopathic tendons.
Collapse
Affiliation(s)
- Su-Ya Lee
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Hsiao-Feng Chieh
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.,Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| | - Chien-Ju Lin
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.,Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| | - I-Ming Jou
- Department of Orthopedics, E-Da Hospital, Kaohsiung, Taiwan.,Department of Orthopedics, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Yung-Nien Sun
- Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan.,Department of Computer Science & Information Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Li-Chieh Kuo
- Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan.,Department of Occupational Therapy, National Cheng Kung University, Tainan, Taiwan
| | - Po-Ting Wu
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan. .,Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan. .,Department of Orthopedics, College of Medicine, National Cheng Kung University, Tainan, Taiwan. .,Department of Orthopedics, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
| | - Fong-Chin Su
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan. .,Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan.
| |
Collapse
|
13
|
Couppé C, Svensson RB, Heinemeier KM, Thomsen EW, Bayer ML, Christensen L, Kjær M, Magnusson SP, Schjerling P. Quantification of cell density in rat Achilles tendon: development and application of a new method. Histochem Cell Biol 2016; 147:97-102. [PMID: 27565969 DOI: 10.1007/s00418-016-1482-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/21/2016] [Indexed: 01/03/2023]
Abstract
Increased tendon cell nuclei density (TCND) has been proposed to induce tendon mechanical adaptations. However, it is unknown whether TCND is increased in tendon tissue after mechanical loading and whether such an increase can be quantified in a reliable manner. The aim of this study was to develop a reliable method for quantification of TCND and to investigate potential changes in TCND in rat Achilles tendons in response to 12 weeks of running. Eight adult male Sprague-Dawley rats ran (RUN) on a treadmill with 10° incline, 1 h/day, 5 days/wk (17-20 m/min) for 12 weeks (which improved tendon mechanical properties) and were compared with 11 control rats (SED). Tissue-Tek-embedded cryosections (10 µm) from the mid region of the Achilles tendon were cut longitudinally on a cryostat. Sections were stained with alcian blue and picrosirius red. One blinded investigator counted the number of tendon cell nuclei 2-3 times in three separate regions of the mid longitudinal tendon sections with fields of 390 μm × 280 μm. Unpaired t tests were used for the statistical analysis (mean ± SE). Typical Error % for replicate counts was 5.5 and 14 % coefficient of variation for the three regions. There was no difference in TCND between running rats versus control rats (nuclei per image (≈105 μm2): RUN, 152 ± 9; SED, 146 ± 8, p = 0.642). This new method provided reproducible quantification of TCND. There was no difference in TCND despite improvements in tendon mechanics, which suggests that cell number is not a major cause for altered tendon mechanical properties with loading.
Collapse
Affiliation(s)
- Christian Couppé
- IOC Sports Medicine, Department of Orthopedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Building 8, Bispebjerg Bakke 23, 2400, Copenhagen NV, Denmark. .,Musculoskeletal Rehabilitation Research Unit, Department of Physical Therapy, Bispebjerg Hospital, Copenhagen, Denmark.
| | - René B Svensson
- IOC Sports Medicine, Department of Orthopedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Building 8, Bispebjerg Bakke 23, 2400, Copenhagen NV, Denmark
| | - Katja M Heinemeier
- IOC Sports Medicine, Department of Orthopedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Building 8, Bispebjerg Bakke 23, 2400, Copenhagen NV, Denmark.,Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Emilie Wøjdemann Thomsen
- IOC Sports Medicine, Department of Orthopedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Building 8, Bispebjerg Bakke 23, 2400, Copenhagen NV, Denmark
| | - Monika Lucia Bayer
- IOC Sports Medicine, Department of Orthopedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Building 8, Bispebjerg Bakke 23, 2400, Copenhagen NV, Denmark
| | | | - Michael Kjær
- IOC Sports Medicine, Department of Orthopedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Building 8, Bispebjerg Bakke 23, 2400, Copenhagen NV, Denmark
| | - S Peter Magnusson
- IOC Sports Medicine, Department of Orthopedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Building 8, Bispebjerg Bakke 23, 2400, Copenhagen NV, Denmark.,Musculoskeletal Rehabilitation Research Unit, Department of Physical Therapy, Bispebjerg Hospital, Copenhagen, Denmark
| | - Peter Schjerling
- IOC Sports Medicine, Department of Orthopedic Surgery M, Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Building 8, Bispebjerg Bakke 23, 2400, Copenhagen NV, Denmark
| |
Collapse
|
14
|
Yuan T, Zhang J, Zhao G, Zhou Y, Zhang CQ, Wang JHC. Creating an Animal Model of Tendinopathy by Inducing Chondrogenic Differentiation with Kartogenin. PLoS One 2016; 11:e0148557. [PMID: 26848746 PMCID: PMC4744046 DOI: 10.1371/journal.pone.0148557] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2015] [Accepted: 01/20/2016] [Indexed: 11/18/2022] Open
Abstract
Previous animal studies have shown that long term rat treadmill running induces over-use tendinopathy, which manifests as proteoglycan accumulation and chondrocytes-like cells within the affected tendons. Creating this animal model of tendinopathy by long term treadmill running is however time-consuming, costly and may vary among animals. In this study, we used a new approach to develop an animal model of tendinopathy using kartogenin (KGN), a bio-compound that can stimulate endogenous stem/progenitor cells to differentiate into chondrocytes. KGN-beads were fabricated and implanted into rat Achilles tendons. Five weeks after implantation, chondrocytes and proteoglycan accumulation were found at the KGN implanted site. Vascularity as well as disorganization in collagen fibers were also present in the same site along with increased expression of the chondrocyte specific marker, collagen type II (Col. II). In vitro studies confirmed that KGN was released continuously from KGN-alginate in vivo beads and induced chondrogenic differentiation of tendon stem/progenitor cells (TSCs) suggesting that chondrogenesis after KGN-bead implantation into the rat tendons is likely due to the aberrant differentiation of TSCs into chondrocytes. Taken together, our results showed that KGN-alginate beads can be used to create a rat model of tendinopathy, which, at least in part, reproduces the features of over-use tendinopathy model created by long term treadmill running. This model is mechanistic (stem cell differentiation), highly reproducible and precise in creating localized tendinopathic lesions. It is expected that this model will be useful to evaluate the effects of various topical treatments such as NSAIDs and platelet-rich plasma (PRP) for the treatment of tendinopathy.
Collapse
Affiliation(s)
- Ting Yuan
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA, United States of America
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiaotong University, Shanghai, China
| | - Jianying Zhang
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA, United States of America
| | - Guangyi Zhao
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA, United States of America
| | - Yiqin Zhou
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA, United States of America
| | - Chang-Qing Zhang
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiaotong University, Shanghai, China
| | - James H-C. Wang
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA, United States of America
- * E-mail:
| |
Collapse
|
15
|
Wood LK, Brooks SV. Ten weeks of treadmill running decreases stiffness and increases collagen turnover in tendons of old mice. J Orthop Res 2016; 34:346-53. [PMID: 25640809 DOI: 10.1002/jor.22824] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2014] [Accepted: 01/07/2015] [Indexed: 02/04/2023]
Abstract
Increased tendon stiffness in response to mechanical loading is well established in young animals. Given that tendons stiffen with aging, we aimed to determine the effect of increased loading on tendons of old animals. We subjected 28-month-old mice to 10 weeks of uphill treadmill running; sedentary 8- and 28-month-old mice served as controls. Following training, plantaris tendon stiffness and modulus were reduced by approximately half, such that the values were not different from those of tendons from adult sedentary animals. The decrease in plantaris tendon stiffness was accompanied by a similar reduction in the levels of advanced glycation end-product protein adducts in tibialis anterior tendons of trained compared with sedentary old mice. In Achilles tendons, elevated mRNA levels for collagen type 1, matrix-metalloproteinase-8, and lysyl oxidase following training suggest that collagen turnover was likely also increased. The dramatic mechanical and structural changes induced by training occurred independent of changes in cell density or tendon morphology. Finally, Achilles tendon calcification was significantly reduced following exercise. These results demonstrate that, in response to exercise, tendons from old animals are capable of replacing damaged and dysfunctional components of extracellular matrix with tissue that is mechanically and structurally comparable to adult tissue.
Collapse
Affiliation(s)
- Lauren K Wood
- Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| | - Susan V Brooks
- Biomedical Engineering, University of Michigan, Ann Arbor, Michigan.,Department of Molecular and Integrative Physiology, 109 Zina Pitcher Place, BSRB 2029, Ann Arbor, Michigan, 48109
| |
Collapse
|
16
|
Choi MC, Cheung KK, Ng GYF, Zheng YP, Cheing GLY. Measurement of diabetic wounds with optical coherence tomography-based air-jet indentation system and a material testing system. J Wound Care 2015; 24:519, 522-4, 526-8. [PMID: 26551644 DOI: 10.12968/jowc.2015.24.11.519] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Material testing system is a conventional but destructive method for measuring the biomechanical properties of wound tissues in basic research. The recently developed optical coherence tomography-based air-jet indentation system is a non-destructive method for measuring these properties of soft tissues in a non-contact manner. The aim of the study was to examine the correlation between the biomechanical properties of wound tissues measured by the two systems. METHOD Young male Sprague-Dawley rats with streptozotocin-induced diabetic were wounded by a 6 mm biopsy punch on their hind limbs. The biomechanical properties of wound tissues were assessed with the two systems on post-wounding days 3, 7, 10, 14, and 21. Wound sections were stained with picro-sirius red for analysis on the collagen fibres. Data obtained on the different days were charted to obtain the change in biomechanical properties across the time points, and then pooled to examine the correlation between measurements made by the two devices. Qualitative analysis to determine any correlation between indentation stiffness measured by the air-jet indentation system and the orientation of collagen fibres. RESULTS The indentation stiffness is significantly negatively correlated to the maximum load, maximum tensile stress, and Young's modulus by the material testing system (all p<0.05). The orientation of collagen changes with the indentation stiffness over time. CONCLUSION Our findings support the use of optical coherence tomography-based air-jet indentation system to evaluate the biomechanical properties of wounds in a non-contact manner. It is a potential clinical device to examine the biomechanical properties of chronic wounds in vivo in a repeatable manner.
Collapse
Affiliation(s)
- M-C Choi
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - K-K Cheung
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - G Y-F Ng
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Y-P Zheng
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - G L-Y Cheing
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China
| |
Collapse
|
17
|
Kim BS, Joo YC, Choi BH, Kim KH, Kang JS, Park SR. The effect of dry needling and treadmill running on inducing pathological changes in rat Achilles tendon. Connect Tissue Res 2015; 56:452-60. [PMID: 26076317 DOI: 10.3109/03008207.2015.1052876] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Achilles tendinopathy is a common degenerative condition without a definitive treatment. An adequate chronic animal model of Achilles tendinopathy has not yet been developed. The purpose of this study was to evaluate the individual and combined effects of dry needling and treadmill running on the Achilles tendon of rats. Percutaneous dry needling, designed to physically replicate microrupture of collagen fibers in overloaded tendons, was performed on the right Achilles tendon of 80 Sprague-Dawley rats. The rats were randomly divided into two groups: a treadmill group, which included rats that underwent daily uphill treadmill running (n = 40), and a cage group, which included rats that could move freely within their cages (n = 40). At the end of weeks 1 and 4, 20 rats from each group were sacrificed, and bilateral Achilles tendons were collected. The harvested tendons were subjected to mechanical testing and histological analysis. Dry needling induced histological and mechanical changes in the Achilles tendons at week 1, and the changes persisted at week 4. The needled Achilles tendons of the treadmill group tended to show more severe histological and mechanical changes than those of the cage group, although these differences were not statistically significant. Dry needling combined with free cage activity or treadmill running produced tendinopathy-like changes in rat Achilles tendons up to 4 weeks after injury. Dry needling is an easy procedure with a short induction period and a high success rate, suggesting it may have relevance in the design of an Achilles tendinopathy model.
Collapse
Affiliation(s)
- Bom Soo Kim
- a Department of Orthopaedic Surgery , Inha University College of Medicine , Incheon , Korea
| | - Young Chae Joo
- b Department of Pathology , Inha University College of Medicine , Incheon , Korea
| | - Byung Hyune Choi
- c Division of Biomedical and Bioengineering Sciences , Inha University College of Medicine , Incheon , Korea , and
| | - Kil Hwan Kim
- d Department of Physiology , Inha University College of Medicine , Incheon , Korea
| | - Joon Soon Kang
- a Department of Orthopaedic Surgery , Inha University College of Medicine , Incheon , Korea
| | - So Ra Park
- d Department of Physiology , Inha University College of Medicine , Incheon , Korea
| |
Collapse
|
18
|
Jafari L, Vachon P, Beaudry F, Langelier E. Histopathological, biomechanical, and behavioral pain findings of Achilles tendinopathy using an animal model of overuse injury. Physiol Rep 2015; 3:3/1/e12265. [PMID: 25602018 PMCID: PMC4387767 DOI: 10.14814/phy2.12265] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
Animal models of forced running are used to study overuse tendinopathy, a common health problem for which clear evidence for effective and accessible treatments is still lacking. In these models, pain evaluation is necessary to better understand the disease, help design and evaluate therapies, and ensure humane treatment of the animals. Therefore, the main objective of this study was to evaluate pain and pathologic findings in an animal model of moderate Achilles tendinopathy induced by treadmill running. Air puffs, instead of electrical shocks, were used to stimulate running so that pain associated with stimulation would be avoided. Pressure pain sensitivity was evaluated in vivo using a new instrumented plier, whereas spinal cord peptides were analyzed ex vivo with high‐performance liquid chromatography tandem mass spectrometry. Tendon histologic slides were semiquantitatively evaluated, using the Bonar score technique and biomechanical properties, using the traction test. After 8 weeks of treadmill running (2 weeks for adaptation and 6 weeks for the lesion protocol), the protocol was stopped because the air puffs became ineffective to stimulate running. We, nevertheless, observed some histologic changes characteristic of overuse tendinopathy as well as decreased mechanical properties, increased Substance P and dynorphin A peptides but without pressure pain sensitivity. These results suggest that air‐puffs stimulation is sufficient to induce an early stage tendinopathy to study new therapeutic drugs without inducing unnecessary pain. They also indicate that pain‐associated peptides could be related with movement evoked pain and with the sharp breakdown of the running performance. The main objective of this study was to correlate pain and pathologic findings in an animal model of moderate Achilles tendinopathy induced by treadmill running. We observed some histologic changes characteristic of overuse tendinopathy as well as decreased mechanical properties, increased Substance P and dynorphin A peptides but without pressure pain sensitivity.
Collapse
Affiliation(s)
- Leila Jafari
- Département de génie mécanique, Université de Sherbrooke, Sherbrooke, Québec, Canada
| | - Pascal Vachon
- Département de Biomédecine Vétérinaire, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Québec, Canada
| | - Francis Beaudry
- Département de Biomédecine Vétérinaire, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Québec, Canada
| | - Eve Langelier
- Département de génie mécanique, Université de Sherbrooke, Sherbrooke, Québec, Canada
| |
Collapse
|
19
|
Abstract
Tendinopathy is a debilitating musculoskeletal
condition which can cause significant pain and lead to complete rupture
of the tendon, which often requires surgical repair. Due in part
to the large spectrum of tendon pathologies, these disorders continue
to be a clinical challenge. Animal models are often used in this
field of research as they offer an attractive framework to examine
the cascade of processes that occur throughout both tendon pathology and
repair. This review discusses the structural, mechanical, and biological
changes that occur throughout tendon pathology in animal models,
as well as strategies for the improvement of tendon healing. Cite this article: Bone Joint Res 2014;3:193–202.
Collapse
Affiliation(s)
- M W Hast
- University of Pennsylvania, McKay Orthopaedic Research Laboratory, 424 Stemmler Hall 36th Street and Hamilton Walk, Philadelphia, 19104-6081, USA
| | - A Zuskov
- University of Pennsylvania, McKay Orthopaedic Research Laboratory, 424 Stemmler Hall 36th Street and Hamilton Walk, Philadelphia, 19104-6081, USA
| | - L J Soslowsky
- University of Pennsylvania, McKay Orthopaedic Research Laboratory, 424 Stemmler Hall 36th Street and Hamilton Walk, Philadelphia, 19104-6081, USA
| |
Collapse
|
20
|
Chao CYL, Ng GYF, Cheung KK, Zheng YP, Wang LK, Cheing GLY. In vivo and ex vivo approaches to studying the biomechanical properties of healing wounds in rat skin. J Biomech Eng 2014; 135:101009-8. [PMID: 23897493 DOI: 10.1115/1.4025109] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2013] [Accepted: 07/29/2013] [Indexed: 11/08/2022]
Abstract
An evaluation of wound mechanics is crucial in reflecting the wound healing status. The present study examined the biomechanical properties of healing rat skin wounds in vivo and ex vivo. Thirty male Sprague-Dawley rats, each with a 6 mm full-thickness circular punch biopsied wound at both posterior hind limbs were used. The mechanical stiffness at both the central and margins of the wound was measured repeatedly in five rats over the same wound sites to monitor the longitudinal changes over time of before wounding, and on days 0, 3, 7, 10, 14, and 21 after wounding in vivo by using an optical coherence tomography-based air-jet indentation system. Five rats were euthanized at each time point, and the biomechanical properties of the wound tissues were assessed ex vivo using a tensiometer. At the central wound bed region, the stiffness measured by the air-jet system increased significantly from day 0 (17.2%), peaked at day 7 (208.3%), and then decreased progressively until day 21 (40.2%) as compared with baseline prewounding status. The biomechanical parameters of the skin wound samples measured by the tensiometer showed a marked reduction upon wounding, then increased with time (all p < 0.05). On day 21, the ultimate tensile strength of the skin wound tissue approached 50% of the normal skin; while the stiffness of tissue recovered at a faster rate, reaching 97% of its prewounded state. Our results suggested that it took less time for healing wound tissues to recover their stiffness than their maximal strength in rat skin. The stiffness of wound tissues measured by air-jet could be an indicator for monitoring wound healing and contraction.
Collapse
|
21
|
Seo DY, Lee SR, Kim N, Ko KS, Rhee BD, Han J. Humanized animal exercise model for clinical implication. Pflugers Arch 2014; 466:1673-87. [PMID: 24647666 DOI: 10.1007/s00424-014-1496-0] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2014] [Revised: 03/03/2014] [Accepted: 03/05/2014] [Indexed: 01/20/2023]
Abstract
Exercise and physical activity function as a patho-physiological process that can prevent, manage, and regulate numerous chronic conditions, including metabolic syndrome and age-related sarcopenia. Because of research ethics and technical difficulties in humans, exercise models using animals are requisite for the future development of exercise mimetics to treat such abnormalities. Moreover, the beneficial or adverse outcomes of a new regime or exercise intervention in the treatment of a specific condition should be tested prior to implementation in a clinical setting. In rodents, treadmill running (or swimming) and ladder climbing are widely used as aerobic and anaerobic exercise models, respectively. However, exercise models are not limited to these types. Indeed, there are no golden standard exercise modes or protocols for managing or improving health status since the types (aerobic vs. anaerobic), time (morning vs. evening), and duration (continuous vs. acute bouts) of exercise are the critical determinants for achieving expected beneficial effects. To provide insight into the understanding of exercise and exercise physiology, we have summarized current animal exercise models largely based on aerobic and anaerobic criteria. Additionally, specialized exercise models that have been developed for testing the effect of exercise on specific physiological conditions are presented. Finally, we provide suggestions and/or considerations for developing a new regime for an exercise model.
Collapse
Affiliation(s)
- Dae Yun Seo
- National Research Laboratory for Mitochondrial Signaling, Department of Physiology, College of Medicine, Department of Health Sciences and Technology, Cardiovascular and Metabolic Disease Center, Inje University, Bok Ji-Ro 75, Busanjin-Gu, Busan, 613-735, Republic of Korea
| | | | | | | | | | | |
Collapse
|
22
|
Pingel J, Wienecke J, Kongsgaard M, Behzad H, Abraham T, Langberg H, Scott A. Increased mast cell numbers in a calcaneal tendon overuse model. Scand J Med Sci Sports 2013; 23:e353-60. [PMID: 23889295 PMCID: PMC4282450 DOI: 10.1111/sms.12089] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/02/2013] [Indexed: 02/06/2023]
Abstract
Tendinopathy is often discovered late because the initial development of tendon pathology is asymptomatic. The aim of this study was to examine the potential role of mast cell involvement in early tendinopathy using a high-intensity uphill running (HIUR) exercise model. Twenty-four male Wistar rats were divided in two groups: running group (n = 12); sedentary control group (n = 12). The running-group was exposed to the HIUR exercise protocol for 7 weeks. The calcaneal tendons of both hind limbs were dissected. The right tendon was used for histologic analysis using Bonar score, immunohistochemistry, and second harmonic generation microscopy (SHGM). The left tendon was used for quantitative polymerase chain reaction (qPCR) analysis. An increased tendon cell density in the runners were observed compared to the controls (P = 0.05). Further, the intensity of immunostaining of protein kinase B, P = 0.03; 2.75 ± 0.54 vs 1.17 ± 0.53, was increased in the runners. The Bonar score (P = 0.05), and the number of mast cells (P = 0.02) were significantly higher in the runners compared to the controls. Furthermore, SHGM showed focal collagen disorganization in the runners, and reduced collagen density (P = 0.03). IL-3 mRNA levels were correlated with mast cell number in sedentary animals. The qPCR analysis showed no significant differences between the groups in the other analyzed targets. The current study demonstrates that 7-week HIUR causes structural changes in the calcaneal tendon, and further that these changes are associated with an increased mast cell density.
Collapse
Affiliation(s)
- J Pingel
- Institute of Sports Medicine, Department of Orthopaedic Surgery M. Bispebjerg Hospital and Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Copenhagen, Denmark
| | | | | | | | | | | | | |
Collapse
|
23
|
Wang L, Huang MJ, Yin GH, Zhang ZM, Jin J, Lai PL, Yan B, Huang B, Bai XC, Jin DD. WITHDRAWN: Characterization of a novel calcific Achilles tendinopathy model in mice: contralateral tendinopathy induced by unilateral tenotomy. J Surg Res 2013. [DOI: 10.1016/j.jss.2013.10.059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
24
|
Dirks RC, Galley MR, Childress PJ, Fearon AM, Scott A, Koch LG, Britton SL, Warden SJ. Uphill running does not exacerbate collagenase-induced pathological changes in the Achilles tendon of rats selectively bred for high-capacity running. Connect Tissue Res 2013; 54:386-93. [PMID: 24060053 DOI: 10.3109/03008207.2013.848201] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The Achilles tendon is a frequent site for degeneration, and advanced understanding of this pathology requires an animal model that replicates the human condition. The aim of this study was to explore whether intratendinous collagenase injection combined with treadmill running created a pathology in the rat Achilles tendon consistent with human Achilles tendinosis. Collagenase was injected into one Achilles tendon of 88 high-capacity running (HCR) rats, which were randomized into treadmill running and cage control groups. Running animals ran at speeds up to 30 m/min on a treadmill at a 15° incline for up to 1 h/d, 5 d/week for 4 or 10 weeks. Cage control animals maintained cage activity. Collagenase induced molecular, histopathological and mechanical changes within the Achilles tendon at 4 weeks. The mechanical changes persisted at 10 weeks; however, the histopathological and majority of the molecular changes were no longer present at 10 weeks. Treadmill running had minimal effect and did not exacerbate the collagenase-induced changes as there were no statistical interactions between the interventions. These data suggest combined intratendinous collagenase injection and treadmill running does not create pathology within the Achilles tendon of rats selectively bred for HCR that is consistent with human Achilles tendinosis.
Collapse
Affiliation(s)
- Rachel C Dirks
- Center for Translational Musculoskeletal Research, School of Health and Rehabilitation Sciences, Indiana University , Indianapolis, IN , USA
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Franchi M, Torricelli P, Giavaresi G, Fini M. Role of moderate exercising on Achilles tendon collagen crimping patterns and proteoglycans. Connect Tissue Res 2013; 54:267-74. [PMID: 23758268 DOI: 10.3109/03008207.2013.807808] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
In this study, the morphological and morphometric changes in the collagen crimping pattern of Achilles tendon and metabolism/expression of tenocytes explanted from tendons of running (RUN) and sedentary (SED) rats were investigated to assess the effects of 12 weeks moderate running exercise. The number, the top angle width and the base length of each crimp in three different regions (proximal, central and distal) of RUN and SED tendons were measured with a polarized light microscope. The most significant morphometric differences in the crimps were detectable in the central region of the RUN tendons. In this region, crimps were fewer, larger and more flattened than those of other regions as a consequence of a functional adaptation of extracellular matrix to running, in order to increase tendon stiffness and force transmission efficiency. Conversely, the top angle width of the crimps reduced in proximal and distal regions of the RUN tendons, suggesting that these crimps might act as more reactive mechanical springs, able to store and improve the release of the stored strain energy in most loaded regions. Tenocytes explanted from Achilles tendons of both RUN and SED groups were cultured. Running influenced tenocytes which showed a significant increase in collagen type-I synthesis and proteoglycans production, suggesting enhancement of the loading transmission efficiency and facilitate inter-fibril and inter-fiber sliding.
Collapse
Affiliation(s)
- Marco Franchi
- Department for Life Quality Studies, Faculty of Exercise and Sport Sciences, University of Bologna , Bologna , Italy
| | | | | | | |
Collapse
|
26
|
Uphill treadmill running does not induce histopathological changes in the rat Achilles tendon. BMC Musculoskelet Disord 2013; 14:90. [PMID: 23496843 PMCID: PMC3599857 DOI: 10.1186/1471-2474-14-90] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2012] [Accepted: 03/06/2013] [Indexed: 11/25/2022] Open
Abstract
Background The purpose of this study was to investigate whether uphill treadmill running in rats created histopathological changes within the Achilles tendon consistent with Achilles tendinosis in humans. Methods Twenty-six mature rats selectively bred for high-capacity running were divided into run and cage control groups. Run group rats ran on a treadmill at a 15° incline for a maximum duration of 1 hr/d, 5 d/wk for 9 weeks at increasing speeds, while rats in the cage control group maintained normal cage activity. After 9 weeks, Achilles tendons were harvested for histological processing and semi-quantitative histopathological analysis. Results There were no significant group differences within each of the individual histopathological categories assessed (all p ≥ 0.16) or for total histopathological score (p = 0.14). Conclusions Uphill treadmill running in rats selectively bred for high-capacity running did not generate Achilles tendon changes consistent with the histopathological presentation of Achilles tendinosis in humans.
Collapse
|
27
|
Heinemeier KM, Skovgaard D, Bayer ML, Qvortrup K, Kjaer A, Kjaer M, Magnusson SP, Kongsgaard M. Uphill running improves rat Achilles tendon tissue mechanical properties and alters gene expression without inducing pathological changes. J Appl Physiol (1985) 2012; 113:827-36. [PMID: 22797314 DOI: 10.1152/japplphysiol.00401.2012] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Overuse Achilles tendinopathy is a common and challenging problem in sports medicine. Little is known about the etiology of this disorder, and the development of a good animal model for overuse tendinopathy is essential for advancing insight into the disease mechanisms. Our aim was to test a previously proposed rat model for Achilles tendon overuse. Ten adult male Sprague-Dawley rats ran on a treadmill with 10° incline, 1 h/day, 5 days/wk (17-20 m/min) for 12 wk and were compared with 12 control rats. Histological, mechanical, and gene-expression changes were measured on the Achilles tendons after the intervention, and local tendon glucose-uptake was measured before and after the intervention with positron emission tomography. No differences were detected between runners and controls in tissue histology or in glucose uptake, indicating that tendon pathology was not induced. Greater tendon tissue modulus (P < 0.005) and failure stress/body weight (P < 0.02) in runners compared with controls further supported that tendons successfully adapted to uphill running. Several genes of interest were regulated after 12 wk of running. Expression of collagen III and insulin-like growth factor I was increased, while collagen I was unchanged, and decreases were seen in noncollagen matrix components (fibromodulin and biglycan), matrix degrading enzymes, transforming growth factor-β1, and connective tissue growth factor. In conclusion, the tested model could not be validated as a model for Achilles tendinopathy, as the rats were able to adapt to 12 wk of uphill running without any signs of tendinopathy. Improved mechanical properties were observed, as well as changes in gene-expression that were distinctly different from what is seen in tendinopathy and in response to short-term tendon loading.
Collapse
Affiliation(s)
- K M Heinemeier
- Institute of Sports Medicine, Department of Orthopedic Surgery M81, Bispebjerg Hospital and Centre of Healthy Ageing, Faculty of Health Sciences, University of Copenhagen, Copenhagen, Denmark
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Ng GYF, Chung PYM. Effects of a therapeutic laser and passive stretching program for treating tendon overuse. Photomed Laser Surg 2012; 30:155-9. [PMID: 22235970 DOI: 10.1089/pho.2011.3095] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
OBJECTIVE This study investigated the effects of a therapeutic laser, passive stretching, and their combined treatment on the strength of Achilles tendons with overuse pathologies. BACKGROUND DATA Tendinopathy involving overuse is usually treated with exercise and stretching, but there has been no report on the treatment effect of a therapeutic laser combined with passive stretching on managing this condition. Despite the beneficial effect of a therapeutic laser on healing tendons that have had traumatic injury, its effect on degenerative tendons is not known. METHODS Twenty-five mature Sprague-Dawley (SD) rats were used, with 20 subjected to daily bipedal downhill running for 8 weeks, to induce Achilles overuse, and 5 as normal controls. The exercised rats were divided into four groups: 1, laser treatment; 2, passive stretching; 3, combined laser and stretching; and 4, no treatment, running controls. GaAlAs laser with 660 nm wavelength was applied to both Achilles tendons for 50 sec for Groups 1 and 3. Passive stretching of 20 times/10 sec of maximum ankle plantar flexion was applied to Groups 2 and 3. Treatments were applied after each running session for a a total of 56 treatment sessions. On week 9, the tendons were tested for load-relaxation, stiffness, and ultimate strength. RESULTS Stiffness was different (p=0.01), difference in ultimate strength was marginally insignificant (p=0.07), and load-relaxation difference was not significant among groups. Post-hoc analyses revealed that the mean stiffness of all the four exercise groups was lower than the normal control, whereas the ultimate strength from the laser and combined laser and stretching was not different from that of the normal control group, but was higher than that of the passive stretching and no treatment groups. CONCLUSIONS We conclude that a therapeutic laser and combined laser with passive stretching might slow down the decrease in Achilles tendon strength but would not be able to stop the pathological changes of overuse from developing.
Collapse
Affiliation(s)
- Gabriel Y F Ng
- Department of Rehabilitation Sciences, Hong Kong Polytechnic University, Hong Kong (SAR), China.
| | | |
Collapse
|