1
|
Ssegonja R, Ljunggren M, Sampaio F, Tegelmo T, Theorell-Haglöw J. Economic evaluation of telemonitoring as a follow-up approach for patients with obstructive sleep apnea syndrome starting treatment with continuous positive airway pressure. J Sleep Res 2024; 33:e13968. [PMID: 37337981 DOI: 10.1111/jsr.13968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/15/2023] [Accepted: 06/05/2023] [Indexed: 06/21/2023]
Abstract
Telemonitoring of obstructive sleep apnea patients is increasingly being adopted though its cost-effectiveness evidence base is scanty. This study investigated whether telemonitoring is a cost-effective strategy compared with the standard follow-up in patients with obstructive sleep apnea who are starting continuous positive airway pressure treatment. In total, 167 obstructive sleep apnea patients were randomised into telemonitoring (n = 79) or standard follow-up (n = 88), initiated continuous positive airway pressure treatment, and were followed up for 6 months. The frequencies of healthcare contacts, related costs (in USD 2021 prices), treatment effect and compliance were compared between the follow-up approaches using generalised linear models. The cost effectiveness analysis was conducted from a healthcare perspective and the results presented as cost per avoided extra clinic visit. Additionally, patient satisfaction between the two approaches was explored. The analysis showed no baseline differences. At follow-up, there was no significant difference in treatment compliance, and the mean residual apnea-hypoapnea index. There was no difference in total visits, adjusted incidence rate ratio 0.87 (0.72-1.06). Participants in the telemonitoring arm made eight times more telephone visits, 8.10 (5.04-13.84), and about 73% fewer physical healthcare visits 0.27 (0.20-0.36). This translated into significantly lower total costs for the telemonitoring approach compared with standard follow-up, -192 USD (-346 to -41). The form of follow-up seemed to have no impact on the extent of patient satisfaction. These results demonstrate the telemonitoring of patients with obstructive sleep apnea initiating continuous positive airway pressure treatment as a cost saving strategy and can be argued as a potential worthy investment.
Collapse
Affiliation(s)
- Richard Ssegonja
- Department of Medical Sciences, Respiratory, Allergy- and Sleep Medicine Research Unit, Uppsala University, Uppsala, Sweden
- Department of Public Health and Caring Sciences, Uppsala University, Uppsala, Sweden
| | - Mirjam Ljunggren
- Department of Medical Sciences, Respiratory, Allergy- and Sleep Medicine Research Unit, Uppsala University, Uppsala, Sweden
| | - Filipa Sampaio
- Department of Public Health and Caring Sciences, Uppsala University, Uppsala, Sweden
| | - Tove Tegelmo
- Department of Medical Sciences, Respiratory, Allergy- and Sleep Medicine Research Unit, Uppsala University, Uppsala, Sweden
| | - Jenny Theorell-Haglöw
- Department of Medical Sciences, Respiratory, Allergy- and Sleep Medicine Research Unit, Uppsala University, Uppsala, Sweden
| |
Collapse
|
2
|
Schisano M, Libra A, Rizzo L, Morana G, Mancuso S, Ficili A, Campagna D, Vancheri C, Bonsignore MR, Spicuzza L. Distance follow-up by a remote medical care centre improves adherence to CPAP in patients with obstructive sleep apnoea over the short and long term. J Telemed Telecare 2024:1357633X241238483. [PMID: 38532732 DOI: 10.1177/1357633x241238483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/28/2024]
Abstract
BACKGROUND Adherence to continuous positive air pressure (CPAP) in patients with obstructive sleep apnoea (OSA) has remained invariably low over the last decades. Remote monitoring of the nocturnal CPAP treatment, within telemedicine (TM)-based follow-up programs, in these patients has been suggested as a potential tool to improve adherence and release the workload of sleep units. The aim of this study was therefore to assess whether a follow-up program carried out by a Remote Medical Care Centre (RMCC), outside the sleep unit, improves adherence to CPAP in the short and long term in patients with OSA. METHODS In this pilot protocol, we enrolled 37 patients starting CPAP in our Sleep Centre (SC). After three months of standard care in our SC, patients initiated a six-month remote follow-up carried out by the RMCC, functioning as an intermediary between patients and SC. Monthly reports and indication for face-to-face visits were sent to the SC for six months. After this period patients returned to usual care for one year. Results were compared with those obtained in 38 patients (controls) followed with usual care over the same time range. RESULTS Mean nightly use of CPAP increased from 3.2 ± 2.4 h pre-RMCC to 5.2 ± 1.9 h post-RMCC (p < 0.0001). Nights/month of CPAP use improved from 19.8 ± 9.2 to 25.2 ± 2.5 (p < 0.05) and nights/month with CPAP use >4 h from 12.5 ± 10 to 21.03 ± 8.9 (p < 0.05). This improvement remained stable after 12 months from the return of patients to usual care. No significant changes in CPAP use were observed in controls over the time. CONCLUSION A six-month follow-up through a remote facility can significantly improve adherence to CPAP in the short and long term. This pilot study provides a solid base for the design of multicentre randomized trials focusing on new models which are able to increase the long-term efficacy of TM programs.
Collapse
Affiliation(s)
- Matteo Schisano
- Respiratory Unit, University Hospital Policlinico- San Marco, Catania, Italy
| | - Alessandro Libra
- Respiratory Unit, University Hospital Policlinico- San Marco, Catania, Italy
| | - Ludovica Rizzo
- Respiratory Unit, Department of Translational Medicine, Sant'Anna University Hospital, Ferrara, Italy
| | - Giorgio Morana
- Respiratory Unit, University Hospital Policlinico- San Marco, Catania, Italy
- Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| | - Salvatore Mancuso
- Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| | - Antonella Ficili
- Respiratory Unit, University Hospital Policlinico- San Marco, Catania, Italy
- Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| | - Davide Campagna
- Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
- Emergency Unit, University Hospital Policlinico- San Marco, Catania, Italy
| | - Carlo Vancheri
- Respiratory Unit, University Hospital Policlinico- San Marco, Catania, Italy
- Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| | - Maria R Bonsignore
- PROMISE Department, University of Palermo, Palermo, Italy
- Division of Pneumology, Sleep Disordered Breathing Clinic, V. Cervello Hospital, Palermo, Italy
| | - Lucia Spicuzza
- Respiratory Unit, University Hospital Policlinico- San Marco, Catania, Italy
- Department of Clinical and Experimental Medicine, University of Catania, Catania, Italy
| |
Collapse
|
3
|
Xanthopoulos MS, Nelson MN, Eriksen W, Barg FK, Byars KC, Ishman SL, Esbensen AJ, Meinzen-Derr J, Heubi CH, Gurbani NS, Bradford R, Hicks S, Tapia IE. Caregiver experiences helping children with Down syndrome use positive airway pressure to treat obstructive sleep apnea. Sleep Med 2023; 107:179-186. [PMID: 37196396 PMCID: PMC10330846 DOI: 10.1016/j.sleep.2023.04.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 04/12/2023] [Accepted: 04/23/2023] [Indexed: 05/19/2023]
Abstract
BACKGROUND/OBJECTIVE While positive airway pressure (PAP) is an efficacious intervention for the treatment of obstructive sleep apnea syndrome (OSAS) in children with Down syndrome (DS), implementation and consistent use can be difficult. Caregiver perspectives and experiences using PAP are described with the aim of informing clinical practice. METHODS Qualitative semi-structured phone interviews were conducted with 40 caregivers (i.e., mothers) of children with DS and OSAS treated with PAP for at least 6 months. Content analysis was used to identify themes associated with adherence and non-adherence. RESULTS Respondents indicated variability in caregiver experience with the adoption of PAP and observed benefits of PAP. Varied experiences were attributed to several themes including accessing supplies, interactions with the medical team and equipment company, and patients' unique needs and behaviors, including the child's willingness and ability to adapt to PAP, sensory sensitivities, keeping the mask on all night, and differences in daytime behavior. Many families reported that desensitization with a reward system and trust within the caregiver-patient relationship were helpful. Caregiver suggestions for improving PAP adherence for families of children with DS included improving communication with the medical team and medical equipment company, emphasizing patience, using visual supports, and social support and education for extended family. CONCLUSIONS Although family experiences varied, several actionable strategies by both the medical team and families emerged for improving the experience of and adherence to PAP in children with DS.
Collapse
Affiliation(s)
- Melissa S Xanthopoulos
- Sleep Center, Division of Pulmonary and Sleep Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, USA; Department of Child and Adolescent Psychiatry and Behavioral Sciences, Children's Hospital of Philadelphia, Philadelphia, PA, USA; Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
| | - Maria N Nelson
- Mixed Methods Research Lab, Department of Family Medicine and Community Health, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Whitney Eriksen
- Mixed Methods Research Lab, Department of Family Medicine and Community Health, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Frances K Barg
- Mixed Methods Research Lab, Department of Family Medicine and Community Health, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Kelly C Byars
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA; Division of Behavioral Medicine and Clinical Psychology/Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Stacey L Ishman
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA; Division of Pediatric Otolaryngology-Head and Neck Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA; Department of Otolaryngology-Head and Neck Surgery, University of Cincinnati College of Medicine, Cincinnati, OH, USA; Division of Pulmonary and Sleep Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Anna J Esbensen
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA; Division of Developmental and Behavioral Pediatrics, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Jareen Meinzen-Derr
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA; Division of Biostatistics and Epidemiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Christine H Heubi
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA; Division of Pediatric Otolaryngology-Head and Neck Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA; Department of Otolaryngology-Head and Neck Surgery, University of Cincinnati College of Medicine, Cincinnati, OH, USA; Division of Pulmonary and Sleep Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Neepa S Gurbani
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA; Division of Pulmonary and Sleep Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Ruth Bradford
- Sleep Center, Division of Pulmonary and Sleep Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Suzanna Hicks
- Division of Pulmonary and Sleep Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Ignacio E Tapia
- Sleep Center, Division of Pulmonary and Sleep Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, USA; Department of Pediatrics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|