1
|
Campostrini L, Proksch P, Jakwerth S, Farnleitner AH, Kirschner AKT. Introducing bacterial community turnover times to elucidate temporal and spatial hotspots of biological instability in a large Austrian drinking water distribution network. WATER RESEARCH 2024; 252:121188. [PMID: 38324987 DOI: 10.1016/j.watres.2024.121188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 01/16/2024] [Accepted: 01/23/2024] [Indexed: 02/09/2024]
Abstract
Ensuring biological stability in drinking water distribution systems (DWDSs) is important to reduce the risk of aesthetic, operational and hygienic impairments of the distributed water. Drinking water after treatment often changes in quality during transport due to interactions with pipe-associated biofilms, temperature increases and disinfectant residual decay leading to potential biological instability. To comprehensively assess the potential for biological instability in a large chlorinated DWDS, a tool-box of bacterial biomass and activity parameters was applied, introducing bacterial community turnover times (BaCTT) as a direct, sensitive and easy-to-interpret quantitative parameter based on the combination of 3H-leucine incorporation with bacterial biomass. Using BaCTT, hotspots and periods of bacterial growth and potential biological instability could be identified in the DWDS that is fed by water with high bacterial growth potential. A de-coupling of biomass from activity parameters was observed, suggesting that bacterial biomass parameters depict seasonally fluctuating raw water quality rather than processes related to biological stability of the finished water in the DWDS. BaCTT, on the other hand, were significantly correlated to water age, disinfectant residual, temperature and a seasonal factor, indicating a higher potential of biological instability at more distant sampling sites and later in the year. As demonstrated, BaCTT is suggested as a novel, sensitive and very useful parameter for assessing the biological instability potential. However, additional studies in other DWDSs are needed to investigate the general applicability of BaCTT depending on water source, applied treatment processes, biofilm growth potential on different pipe materials, or size, age and complexity of the DWDS.
Collapse
Affiliation(s)
- Lena Campostrini
- Medical University of Vienna, Centre for Pathophysiology, Infectiology and Immunology, Institute for Hygiene and Applied Immunology - Water Microbiology, Kinderspitalgasse 15, Vienna A-1090, Austria; Interuniversity Cooperation Centre Water & Health, Austria
| | - Philipp Proksch
- University of Natural Resources and Life Sciences, Vienna, Institute of Sanitary Engineering and Water Pollution Control, Muthgasse 18, Vienna A-1190, Austria
| | - Stefan Jakwerth
- Medical University of Vienna, Centre for Pathophysiology, Infectiology and Immunology, Institute for Hygiene and Applied Immunology - Water Microbiology, Kinderspitalgasse 15, Vienna A-1090, Austria; Interuniversity Cooperation Centre Water & Health, Austria
| | - Andreas H Farnleitner
- Interuniversity Cooperation Centre Water & Health, Austria; Division Water Quality and Health, Karl Landsteiner University of Health Sciences, Dr. Karl Dorrek-Straße 30, Krems A-3500, Austria; Technische Universität Wien, Institute for Chemical, Environmental and Bioscience Engineering, Research Group Microbiology and Molecular Diagnostics 166/5/3, Gumpendorferstraße 1, Vienna A-1060, Austria
| | - Alexander K T Kirschner
- Medical University of Vienna, Centre for Pathophysiology, Infectiology and Immunology, Institute for Hygiene and Applied Immunology - Water Microbiology, Kinderspitalgasse 15, Vienna A-1090, Austria; Interuniversity Cooperation Centre Water & Health, Austria; Division Water Quality and Health, Karl Landsteiner University of Health Sciences, Dr. Karl Dorrek-Straße 30, Krems A-3500, Austria.
| |
Collapse
|
2
|
Qi W, Skov PV, de Jesus Gregersen KJ, Pedersen LF. A novel method to estimate biofilm activity based on enzymatic oxygen release from hydrogen peroxide decomposition. Biofilm 2023; 5:100121. [PMID: 37090160 PMCID: PMC10119708 DOI: 10.1016/j.bioflm.2023.100121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Revised: 03/14/2023] [Accepted: 04/03/2023] [Indexed: 04/25/2023] Open
Abstract
Biofilm is central for biological water treatment processes in recirculating aquaculture systems (RAS). A lack of suitable methods for quantifying biofilm activity, however, makes it difficult to assess and compare the microbial status of biofilm. This type of information of the biofilm will be useful to assess the colonization status of nitrifying biocarriers or to evaluate the effect of disinfectants on the biofilm activity. Here we introduce a novel assay for rapid assessment of microbial activities in the biofilm attached on bioelements from a RAS biofilter. The assay consisted of an intermittent respirometer platform where biofilter elements were exposed to 10 mg/L hydrogen peroxide (H2O2) for 1 h, following concurrent measurements of oxygen release from the decomposition of H2O2 caused by biofilm-associated enzymes. A different number of colonized, mature bioelements from a moving bed biofilter in a freshwater RAS were tested with repeated H2O2 exposure, and compared against their autoclaved forms. A substantial increase in dissolved oxygen (DO) concentration (0.92-2.31 mg O2/L) occurred with mature bioelements during 1 h of H2O2 exposure, compared to small amounts of DO release (≤0.27 mg O2/L) with autoclaved bioelements. This substantiates that H2O2 decomposition by biofilm is mainly governed by microbial enzymatic activities. A monomolecular model fitted well with the observed oxygen release profiles of tested mature bioelements after H2O2 exposure (R2 > 0.98). The kinetic rate constant of net oxygen release (k or , h-1) was proportional (R2 for linear fit = 0.99) to the number of mature bioelements tested. Repeated exposure of H2O2 to the same bioelements did not change k or , which indicates that 10 mg/L H2O2 with an exposure time of 1 h does not suppress enzymatic activity in biofilm. Our study provides a new rapid method that allows simple quantification of microbial activity in biofilm samples from aquaculture systems, which could potentially be also applied to study biofilm from wastewater treatment plants and other industries.
Collapse
|
3
|
López-Gálvez J, Schiessl K, Besmer MD, Bruckmann C, Harms H, Müller S. Development of an Automated Online Flow Cytometry Method to Quantify Cell Density and Fingerprint Bacterial Communities. Cells 2023; 12:1559. [PMID: 37371029 DOI: 10.3390/cells12121559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 05/09/2023] [Accepted: 06/02/2023] [Indexed: 06/29/2023] Open
Abstract
Cell density is an important factor in all microbiome research, where interactions are of interest. It is also the most important parameter for the operation and control of most biotechnological processes. In the past, cell density determination was often performed offline and manually, resulting in a delay between sampling and immediate data processing, preventing quick action. While there are now some online methods for rapid and automated cell density determination, they are unable to distinguish between the different cell types in bacterial communities. To address this gap, an online automated flow cytometry procedure is proposed for real-time high-resolution analysis of bacterial communities. On the one hand, it allows for the online automated calculation of cell concentrations and, on the other, for the differentiation between different cell subsets of a bacterial community. To achieve this, the OC-300 automation device (onCyt Microbiology, Zürich, Switzerland) was coupled with the flow cytometer CytoFLEX (Beckman Coulter, Brea, USA). The OC-300 performs the automatic sampling, dilution, fixation and 4',6-diamidino-2-phenylindole (DAPI) staining of a bacterial sample before sending it to the CytoFLEX for measurement. It is demonstrated that this method can reproducibly measure both cell density and fingerprint-like patterns of bacterial communities, generating suitable data for powerful automated data analysis and interpretation pipelines. In particular, the automated, high-resolution partitioning of clustered data into cell subsets opens up the possibility of correlation analysis to identify the operational or abiotic/biotic causes of community disturbances or state changes, which can influence the interaction potential of organisms in microbiomes or even affect the performance of individual organisms.
Collapse
Affiliation(s)
- Juan López-Gálvez
- Department of Environmental Microbiology, Helmholtz-Centre for Environmental Research, Permoserstraße 15, D-04318 Leipzig, Germany
| | | | - Michael D Besmer
- onCyt Microbiology AG, Marchwartstrasse 61, 8038 Zürich, Switzerland
| | - Carmen Bruckmann
- Department of Environmental Microbiology, Helmholtz-Centre for Environmental Research, Permoserstraße 15, D-04318 Leipzig, Germany
| | - Hauke Harms
- Department of Environmental Microbiology, Helmholtz-Centre for Environmental Research, Permoserstraße 15, D-04318 Leipzig, Germany
| | - Susann Müller
- Department of Environmental Microbiology, Helmholtz-Centre for Environmental Research, Permoserstraße 15, D-04318 Leipzig, Germany
| |
Collapse
|
4
|
Koppanen M, Kesti T, Rintala J, Palmroth M. Can online particle counters and electrochemical sensors distinguish normal periodic and aperiodic drinking water quality fluctuations from contamination? THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 872:162078. [PMID: 36764531 DOI: 10.1016/j.scitotenv.2023.162078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 02/02/2023] [Accepted: 02/03/2023] [Indexed: 06/18/2023]
Abstract
Early warning systems monitoring the quality of drinking water need to distinguish between normal quality fluctuations and those caused by contaminants. Thus, to decrease the number of false positive events, normal water quality fluctuations, whether periodic or aperiodic, need to be characterized. For this, we used a novel flow-imaging particle counter, a light-scattering particle counter, and electrochemical sensors to monitor the drinking water quality of a pressure zone in a building complex for 109 days. Data were analyzed to determine the feasibility of the sensors and particle counters to distinguish periodic and aperiodic fluctuations from real-life contaminants. The concentrations of particles smaller than 10 μm and N, Small, Large, and B particles showed sudden changes recurring daily, likely due to the flow rate changes in the building complex. Conversely, the concentrations of larger than 10 μm particles and C particles, in addition to the responses of electrochemical sensors, remained in their low typical values despite flow rate changes. The aperiodic events, likely resulting from an abnormally high flow rate in the water mains due to maintenance, were detected using particle counters and electrochemical sensors. This study provides insights into choosing water quality sensors by showing that machine learning-based particle classes, such as B, C, F, and particles larger than 10 μm are promising in distinguishing contamination from aperiodic and periodic fluctuations while the use of other particle classes and electrochemical sensors may require dynamic baseline to decrease false positive events in an early warning system.
Collapse
Affiliation(s)
- Markus Koppanen
- Faculty of Engineering and Natural Sciences, Tampere University, P.O. Box 541, FI-33101, Tampere, Finland.
| | - Tero Kesti
- Uponor Corporation, Kaskimäenkatu 2, FI-33900 Tampere, Finland
| | - Jukka Rintala
- Faculty of Engineering and Natural Sciences, Tampere University, P.O. Box 541, FI-33101, Tampere, Finland
| | - Marja Palmroth
- Faculty of Engineering and Natural Sciences, Tampere University, P.O. Box 541, FI-33101, Tampere, Finland
| |
Collapse
|
5
|
Koppanen M, Kesti T, Kokko M, Rintala J, Palmroth M. An online flow-imaging particle counter and conventional water quality sensors detect drinking water contamination in the presence of normal water quality fluctuations. WATER RESEARCH 2022; 213:118149. [PMID: 35151088 DOI: 10.1016/j.watres.2022.118149] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 12/20/2021] [Accepted: 01/31/2022] [Indexed: 06/14/2023]
Abstract
Contamination detection in drinking water is crucial for water utilities in terms of public health; however, current online water quality sensors can be unresponsive to various possible contaminants consisting of particulate and dissolved content or require a constant supply of reagents and sample preparation. We used a two-line test environment connected to a drinking water distribution system with flow-imaging particle counters and conventional sensors to assess their responses to the injection of contaminants into one line, including stormwater, treated wastewater, wastewater, well water, and Escherichia coli, while simultaneously measuring responses to normal water quality fluctuations in the other line. These water quality fluctuations were detected with all of the conventional sensors (except conductivity) and with 3 out of 5 of the size- and shape-derived particle classes of the flow-imaging particle counter. The flow-imaging particle counter was able to detect all of the studied contaminants, e.g. municipal wastewater at 0.001% (v/v), while the oxidation-reduction potential sensor outperformed other conventional sensors, detecting the same wastewater at 0.03% (v/v). The presence of particles less than 1 µm in size was shown to be a generic parameter for the detection of particulates present in the studied contaminants; however, they manifested a considerable response to fluctuations which led to lower relative response to contaminants in comparison to larger particles. The particle size and class distributions of contaminants were different from those of drinking water, and thus monitoring particles larger than 1 µm or specific particle classes of flow-imaging particle counter, which are substantially more abundant in contaminated water than in pure drinking water, can improve the detection of contamination events. Water utilities could optimize contamination detection by selecting water quality parameters with a minimal response to quality fluctuations and/or a high relative response to contaminants.
Collapse
Affiliation(s)
- Markus Koppanen
- Faculty of Engineering and Natural Sciences, Tampere University, P.O. Box 541, FI-33101, Tampere, Finland.
| | - Tero Kesti
- Uponor Corporation, Kaskimäenkatu 2, FI-33900 Tampere, Finland
| | - Marika Kokko
- Faculty of Engineering and Natural Sciences, Tampere University, P.O. Box 541, FI-33101, Tampere, Finland
| | - Jukka Rintala
- Faculty of Engineering and Natural Sciences, Tampere University, P.O. Box 541, FI-33101, Tampere, Finland
| | - Marja Palmroth
- Faculty of Engineering and Natural Sciences, Tampere University, P.O. Box 541, FI-33101, Tampere, Finland
| |
Collapse
|
6
|
Provoost C, Rocca GT, Thibault A, Machtou P, Bouilllaguet S. Influence of Needle Design and Irrigant Flow Rate on the Removal of Enterococcus faecalis Biofilms In Vitro. Dent J (Basel) 2022; 10:dj10040059. [PMID: 35448053 PMCID: PMC9030241 DOI: 10.3390/dj10040059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/24/2022] [Accepted: 03/30/2022] [Indexed: 01/27/2023] Open
Abstract
This study aimed to evaluate the influence of needle design and irrigant flow rate on the removal of Enterococcus faecalis mature biofilms during sodium hypochlorite irrigation. Forty-eight single-rooted human teeth were instrumented (ProTaper F3), autoclaved and inoculated with Enterococcus faecalis to establish a two-week-old biofilm. E. faecalis biofilms were treated with Sodium hypochlorite that was injected in the root canals using three types of needles (NaviTip, ProRinse, IrriFlex). For the IrriFlex needle, one, two, or four bars of pressure was applied to the irrigating solution to increase flow rates. Bacteria were labeled with the LIVE/DEAD BacLight Bacterial Viability kit, and viability was assessed by flow cytometry (FCM). Results were statistically analyzed using one-way ANOVA and Tukey multiple comparison intervals (α = 0.05). Bacterial viability was significantly reduced after sodium hypochlorite passive irrigation but the number of viable bacteria retrieved from root canal specimens irrigated with the Pro-Rinse needle was significantly higher compared to NaviTip and IrriFlex needles (p < 0.05). When the irrigant flow rate was increased, the viability of bacterial biofilms was significantly reduced compared to passive irrigation using the IrriFlex needle (p < 0.05). Applying higher flow rates during irrigation using the IrriFlex needle did not further reduce bacterial viability.
Collapse
|
7
|
Boivin S, Tanabe S, Fujioka T. Online evaluation of bacterial cells in sand filter effluents during full-scale treatment of drinking water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 814:152508. [PMID: 34968596 DOI: 10.1016/j.scitotenv.2021.152508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 12/13/2021] [Accepted: 12/14/2021] [Indexed: 06/14/2023]
Abstract
Ensuring the microbiological safety of drinking water is critical to protect public health. This study aimed to evaluate the reliability of real-time bacteriological counter coupled with an online dialysis membrane-based pre-treatment system for continuously monitoring bacterial cell counts in sand filter effluents of a full-scale drinking water treatment plant. The pre-treatment system, which included anion exchange resins (porous polymeric microbeads that trap ions for releasing other ions) for dialysate regeneration, successfully achieved the stable attenuation of background interfering substances (humic acids) during the 19-d test. The real-time bacteriological counter equipped with the pre-treatment system provided a continuous profile of bacterial cell counts in the sand filter effluent (0.2-2.5 × 104 counts/mL). The online analysis identified different timing of concentration peaks between particle and bacterial cell counts after backwashing. Bacterial community analysis revealed that Proteobacteria, Planctomycetes, and Cyanobacteria were the dominating phyla. Further, total bacterial cell counts determined by fluorescence microscopy and SYBR® Green I staining, a commonly accepted parameter, was found to be an indicator of online-monitored bacterial cell counts. The results indicated the potential of monitoring the bacterial cell counts in a sand filter process for providing an early warning of filter failures, which can allow plant operators to diagnose the overall system and provide countermeasures.
Collapse
Affiliation(s)
- Sandrine Boivin
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan
| | - Shuji Tanabe
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan
| | - Takahiro Fujioka
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan.
| |
Collapse
|
8
|
Mao G, Ji M, Xu B, Liu Y, Jiao N. Variation of High and Low Nucleic Acid-Content Bacteria in Tibetan Ice Cores and Their Relationship to Black Carbon. Front Microbiol 2022; 13:844432. [PMID: 35237252 PMCID: PMC8882866 DOI: 10.3389/fmicb.2022.844432] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 01/24/2022] [Indexed: 01/29/2023] Open
Abstract
Nutrient enrichment caused by black carbon (BC) is a major ecological crisis in glacial ecosystems. The microbiological effects of BC were assessed in this study by using fluorescent fingerprinting assay based on flow cytometry (FCM) of bacterial communities with low (LNA) and high (HNA) nucleic acid-content bacteria. Here, we investigated a high-resolution temporal variation of bacterial abundance and LNA/HNA ratio in Tibetan ice cores. Our results revealed that bacterial abundance was proportional to the atmospheric BC on the glaciers. The shift of LNA functional groups to HNA functional groups in glaciers suggested BC emissions increased the proportion of highly active cells. In addition, distinct number of LNA and HNA functional groups was identified between the monsoon and non-monsoon seasons. Westerly winds with high amounts of BC accounted for high ratio of HNA functional groups during the non-monsoon season. In comparison, high moisture during the monsoon season decreased atmospheric BC loading, which increases the ratio of LNA functional groups. Correlations between BC and functional groups were very strong, showing that two functional groups may serve as early-warning indicators of microbiological effects of BC at low trophic level. Our approach provides a potential early-warning framework to study the influences of atmospheric BC on the glaciological community.
Collapse
Affiliation(s)
- Guannan Mao
- Key Laboratory of Tibetan Environment Changes and Land Surface Processes, Institute of Tibetan Plateau Research, Chinese Academy of Sciences, Beijing, China
| | - Mukan Ji
- Center for the Pan-Third Pole Environment, Lanzhou University, Lanzhou, China
| | - Baiqing Xu
- Key Laboratory of Tibetan Environment Changes and Land Surface Processes, Institute of Tibetan Plateau Research, Chinese Academy of Sciences, Beijing, China
- CAS Center for Excellence in Tibetan Plateau Earth Sciences, Chinese Academy of Sciences, Beijing, China
- College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, China
| | - Yongqin Liu
- Key Laboratory of Tibetan Environment Changes and Land Surface Processes, Institute of Tibetan Plateau Research, Chinese Academy of Sciences, Beijing, China
- Center for the Pan-Third Pole Environment, Lanzhou University, Lanzhou, China
- CAS Center for Excellence in Tibetan Plateau Earth Sciences, Chinese Academy of Sciences, Beijing, China
- College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, China
- *Correspondence: Yongqin Liu,
| | - Nianzhi Jiao
- State Key Laboratory of Marine Environmental Science, Xiamen University, Xiamen, China
| |
Collapse
|
9
|
De Vrieze J, Heyer R, Props R, Van Meulebroek L, Gille K, Vanhaecke L, Benndorf D, Boon N. Triangulation of microbial fingerprinting in anaerobic digestion reveals consistent fingerprinting profiles. WATER RESEARCH 2021; 202:117422. [PMID: 34280807 DOI: 10.1016/j.watres.2021.117422] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 07/01/2021] [Accepted: 07/07/2021] [Indexed: 06/13/2023]
Abstract
The anaerobic digestion microbiome has been puzzling us since the dawn of molecular methods for mixed microbial community analysis. Monitoring of the anaerobic digestion microbiome can either take place via a non-targeted holistic evaluation of the microbial community through fingerprinting or by targeted monitoring of selected taxa. Here, we compared four different microbial community fingerprinting methods, i.e., amplicon sequencing, metaproteomics, metabolomics and cytomics, in their ability to characterise the full-scale anaerobic digestion microbiome. Cytometric fingerprinting through cytomics reflects a, for anaerobic digestion, novel, single cell-based approach of direct microbial community fingerprinting by flow cytometry. Three different digester types, i.e., sludge digesters, digesters treating agro-industrial waste and dry anaerobic digesters, each reflected different operational parameters. The α-diversity analysis yielded inconsistent results, especially for richness, across the different methods. In contrast, β-diversity analysis resulted in comparable profiles, even when translated into phyla or functions, with clear separation of the three digester types. In-depth analysis of each method's features i.e., operational taxonomic units, metaproteins, metabolites, and cytometric traits, yielded certain similar features, yet, also some clear differences between the different methods, which was related to the complexity of the anaerobic digestion process. In conclusion, cytometric fingerprinting through flow cytometry is a reliable, fast method for holistic monitoring of the anaerobic digestion microbiome, and the complementary identification of key features through other methods could give rise to a direct interpretation of anaerobic digestion process performance.
Collapse
Affiliation(s)
- Jo De Vrieze
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000, Gent, Belgium; Division of Soil and Water Management, Department of Earth and Environmental sciences, KU Leuven, Kasteelpark Arenberg 20, PO box 2411, B-3001, Leuven, Belgium; Bio- and Chemical Systems Technology, Reactor Engineering and Safety (CREaS), Department of Chemical Engineering, KU Leuven, Celestijnenlaan 200F, PO box 2424, B-3001, Leuven, Belgium.
| | - Robert Heyer
- Bioprocess Engineering, Otto von Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany
| | - Ruben Props
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | - Lieven Van Meulebroek
- Laboratory of Chemical Analysis, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820, Merelbeke, Belgium
| | - Karen Gille
- Bioprocess Engineering, Otto von Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany
| | - Lynn Vanhaecke
- Laboratory of Chemical Analysis, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820, Merelbeke, Belgium
| | - Dirk Benndorf
- Bioprocess Engineering, Otto von Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany; Bioprocess Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Sandtorstraße 1, 39106, Magdeburg, Germany; Microbiology, Anhalt University of Applied Sciences, Bernburger Straße 55, 06354, Köthen, Germany
| | - Nico Boon
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| |
Collapse
|
10
|
Haberkorn I, Off CL, Besmer MD, Buchmann L, Mathys A. Automated Online Flow Cytometry Advances Microalgal Ecosystem Management as in situ, High-Temporal Resolution Monitoring Tool. Front Bioeng Biotechnol 2021; 9:642671. [PMID: 33834018 PMCID: PMC8023406 DOI: 10.3389/fbioe.2021.642671] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 02/19/2021] [Indexed: 12/17/2022] Open
Abstract
Microalgae are emerging as a next-generation biotechnological production system in the pharmaceutical, biofuel, and food domain. The economization of microalgal biorefineries remains a main target, where culture contamination and prokaryotic upsurge are main bottlenecks to impair culture stability, reproducibility, and consequently productivity. Automated online flow cytometry (FCM) is gaining momentum as bioprocess optimization tool, as it allows for spatial and temporal landscaping, real-time investigations of rapid microbial processes, and the assessment of intrinsic cell features. So far, automated online FCM has not been applied to microalgal ecosystems but poses a powerful technology for improving the feasibility of microalgal feedstock production through in situ, real-time, high-temporal resolution monitoring. The study lays the foundations for an application of automated online FCM implying far-reaching applications to impel and facilitate the implementation of innovations targeting at microalgal bioprocesses optimization. It shows that emissions collected on the FL1/FL3 fluorescent channels, harnessing nucleic acid staining and chlorophyll autofluorescence, enable a simultaneous assessment (quantitative and diversity-related) of prokaryotes and industrially relevant phototrophic Chlorella vulgaris in mixed ecosystems of different complexity over a broad concentration range (2.2–1,002.4 cells ⋅μL–1). Automated online FCM combined with data analysis relying on phenotypic fingerprinting poses a powerful tool for quantitative and diversity-related population dynamics monitoring. Quantitative data assessment showed that prokaryotic growth phases in engineered and natural ecosystems were characterized by different growth speeds and distinct peaks. Diversity-related population monitoring based on phenotypic fingerprinting indicated that prokaryotic upsurge in mixed cultures was governed by the dominance of single prokaryotic species. Automated online FCM is a powerful tool for microalgal bioprocess optimization owing to its adaptability to myriad phenotypic assays and its compatibility with various cultivation systems. This allows advancing bioprocesses associated with both microalgal biomass and compound production. Hence, automated online FCM poses a viable tool with applications across multiple domains within the biobased sector relying on single cell–based value chains.
Collapse
Affiliation(s)
- Iris Haberkorn
- Sustainable Food Processing Laboratory, Institute of Food, Nutrition and Health, ETH Zurich, Zurich, Switzerland
| | - Cosima L Off
- Sustainable Food Processing Laboratory, Institute of Food, Nutrition and Health, ETH Zurich, Zurich, Switzerland
| | | | - Leandro Buchmann
- Sustainable Food Processing Laboratory, Institute of Food, Nutrition and Health, ETH Zurich, Zurich, Switzerland.,Bühler AG, Uzwil, Switzerland
| | - Alexander Mathys
- Sustainable Food Processing Laboratory, Institute of Food, Nutrition and Health, ETH Zurich, Zurich, Switzerland
| |
Collapse
|
11
|
Fujioka T, Boivin S. Dialysis as a new pre-treatment technique for online bacterial counting. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 714:136768. [PMID: 31982761 DOI: 10.1016/j.scitotenv.2020.136768] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Revised: 12/24/2019] [Accepted: 01/16/2020] [Indexed: 06/10/2023]
Abstract
Real-time bacteriological counting technology is capable of providing an online profile of bacterial removal during the wastewater treatment process, and can enhance the safety of recycled water for potable water reuse. However, autofluorescence emanating from dissolved organic compounds present in treated wastewater interferes with the analysis. In this study, a novel approach is adopted, viz., dialysis treatment for the removal of dissolved interfering substances from treated wastewater, and the efficiency of this treatment protocol is evaluated as a pre-treatment technique for real-time bacteriological counting. Dialysis using membranes having a molecular weight cut-off (MWCO) of 1000 kDa and 6-8 kDa were found to successfully reduce the intensity of autofluorescence emitted from the interfering substances; whereas the courser dialysis membrane having a MWCO of 1000 kDa was found to be more effective in removing the interfering substances. Here we demonstrate for the first time that continuous online dialysis treatment aids in the direct determination of the bacterial counts in ultrafiltration- and membrane bioreactor-treated wastewaters. The results of the study indicate that the dialysis pre-treatment technique is effective for continuously reducing the concentration of interfering substances in treated wastewater, and thus allows for direct online counting of bacteria.
Collapse
Affiliation(s)
- Takahiro Fujioka
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan.
| | - Sandrine Boivin
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan
| |
Collapse
|
12
|
Favere J, Buysschaert B, Boon N, De Gusseme B. Online microbial fingerprinting for quality management of drinking water: Full-scale event detection. WATER RESEARCH 2020; 170:115353. [PMID: 31881501 DOI: 10.1016/j.watres.2019.115353] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 11/08/2019] [Accepted: 11/27/2019] [Indexed: 06/10/2023]
Abstract
Microbial regrowth during drinking water distribution can result in a variety of problems such as a deviating taste and odor, and may even pose a risk to public health. Frequent monitoring is essential to anticipate events of biological instability, and relevant microbial parameters for operational control of biostability of drinking water should be developed. Here, online flow cytometry and derived biological metrics were used to assess the biological stability of a full-scale drinking water tower during normal and disturbed flow regime. Pronounced operational events, such as switching from drinking water source, and seasonal changes, were detected in the total cell counts, and regrowth was observed despite the short hydraulic residence time of 6-8 h. Based on the flow cytometric fingerprints, the Bray-Curtis dissimilarity was calculated and was developed as unambiguous parameter to indicate or warn for changing microbial drinking water quality during operational events. In the studied water tower, drastic microbial water quality changes were reflected in the Bray-Curtis dissimilarity, which demonstrates its use as an indicator to follow-up and detect microbial quality changes in practice. Hence, the Bray-Curtis dissimilarity can be used in an online setup as a straightforward parameter during full-scale operation of drinking water distribution, and combined with the cell concentration, it serves as an early-warning system for biological instability.
Collapse
Affiliation(s)
- Jorien Favere
- Center for Microbial Ecology and Technology (CMET), Department of Biochemical and Microbial Technology, Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | | | - Nico Boon
- Center for Microbial Ecology and Technology (CMET), Department of Biochemical and Microbial Technology, Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | - Bart De Gusseme
- Center for Microbial Ecology and Technology (CMET), Department of Biochemical and Microbial Technology, Ghent University, Coupure Links 653, B-9000, Gent, Belgium; FARYS, TMVW, Stropstraat 1, B-9000, Gent, Belgium.
| |
Collapse
|
13
|
Mapping Dynamics of Bacterial Communities in a Full-Scale Drinking Water Distribution System Using Flow Cytometry. WATER 2019. [DOI: 10.3390/w11102137] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Microbial monitoring of drinking water is required to guarantee high quality water and to mitigate health hazards. Flow cytometry (FCM) is a fast and robust method that determines bacterial concentrations in liquids. In this study, FCM was applied to monitor the dynamics of the bacterial communities over one year in a full-scale drinking water distribution system (DWDS), following implementation of ultrafiltration (UF) combined with coagulation at the drinking water treatment plant (DWTP). Correlations between the environmental conditions in the DWDS and microbial regrowth were observed, including increases in total cell counts with increasing retention time (correlation coefficient R = 0.89) and increasing water temperature (up to 5.24-fold increase in cell counts during summer). Temporal and spatial biofilm dynamics affecting the water within the DWDS were also observed, such as changes in the percentage of high nucleic acid bacteria with increasing retention time (correlation coefficient R = −0.79). FCM baselines were defined for specific areas in the DWDS to support future management strategies in this DWDS, including a gradual reduction of chloramine.
Collapse
|
14
|
Fujioka T, Makabe R, Mori N, Snyder SA, Leddy M. Assessment of online bacterial particle counts for monitoring the performance of reverse osmosis membrane process in potable reuse. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 667:540-544. [PMID: 30833252 DOI: 10.1016/j.scitotenv.2019.02.339] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Revised: 02/15/2019] [Accepted: 02/21/2019] [Indexed: 06/09/2023]
Abstract
Safety of potable reuse can be enhanced by improved water quality monitoring techniques for assessing water treatment processes. This study evaluated the efficacy of online bacterial counting for continuous monitoring of reverse osmosis (RO) membranes to remove bacteria using real-time bacteriological commercial counters and an on-site pilot-scale RO system. Prior to on-site assessments, the online bacterial counting was verified by comparing the measurement of fluorescent particles in water with flow cytometry. During a seven day pilot test of RO treatment at a water reclamation plant, online bacterial counts in RO permeate were monitored below 15 counts/mL; whereas the bacterial counts in RO feed water were approximately 2500 to 10,000 counts/mL. Removal rates of bacterial counts ranged from 2.6 to 3.1-log (average = 2.9-log) by continuously monitoring bacterial removal. This is greater than a 2-log reduction frequently determined using other water quality surrogates (i.e., electrical conductivity). Overall, the continuous monitoring of bacteria in RO feed and permeate can be implemented without the addition of chemicals to provide near real-time bacterial counts to measure their reduction after RO treatment. This can be developed for continuous performance monitoring of the RO process, providing greater assurance of microbial water quality after RO treatment.
Collapse
Affiliation(s)
- Takahiro Fujioka
- Water and Environmental Engineering, Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan.
| | - Ryo Makabe
- R&D Division, Kyowakiden Industry Co., Ltd., 10-2 Kawaguchi-machi, Nagasaki 852-8108, Japan
| | - Naomichi Mori
- Water Reuse Promotion Center, 4-5 Nihonbashiyokoyamachō, Chuo, Tokyo 103-0003, Japan
| | - Shane A Snyder
- Nanyang Environment & Water Research Institute (NEWRI), Nanyang Technological University (NTU), 1 Cleantech Loop, CleanTech One, Singapore 637141, Singapore; Department of Chemical and Environmental Engineering, University of Arizona, 1133 E. James E. Rogers Way, Harshbarger 108, Tucson, AZ 85721-0011, USA
| | - Menu Leddy
- Orange County Water District, 18700 Ward Street, Fountain Valley, CA 92708, USA; Essential Environmental Engineering Solutions, Huntington Beach, CA 92649, USA
| |
Collapse
|
15
|
Safford HR, Bischel HN. Flow cytometry applications in water treatment, distribution, and reuse: A review. WATER RESEARCH 2019; 151:110-133. [PMID: 30594081 DOI: 10.1016/j.watres.2018.12.016] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 11/30/2018] [Accepted: 12/01/2018] [Indexed: 06/09/2023]
Abstract
Ensuring safe and effective water treatment, distribution, and reuse requires robust methods for characterizing and monitoring waterborne microbes. Methods widely used today can be limited by low sensitivity, high labor and time requirements, susceptibility to interference from inhibitory compounds, and difficulties in distinguishing between viable and non-viable cells. Flow cytometry (FCM) has recently gained attention as an alternative approach that can overcome many of these challenges. This article critically and systematically reviews for the first time recent literature on applications of FCM in water treatment, distribution, and reuse. In the review, we identify and examine nearly 300 studies published from 2000 to 2018 that illustrate the benefits and challenges of using FCM for assessing source-water quality and impacts of treatment-plant discharge on receiving waters, wastewater treatment, drinking water treatment, and drinking water distribution. We then discuss options for combining FCM with other indicators of water quality and address several topics that cut across nearly all applications reviewed. Finally, we identify priority areas in which more work is needed to realize the full potential of this approach. These include optimizing protocols for FCM-based analysis of waterborne viruses, optimizing protocols for specifically detecting target pathogens, automating sample handling and preparation to enable real-time FCM, developing computational tools to assist data analysis, and improving standards for instrumentation, methods, and reporting requirements. We conclude that while more work is needed to realize the full potential of FCM in water treatment, distribution, and reuse, substantial progress has been made over the past two decades. There is now a sufficiently large body of research documenting successful applications of FCM that the approach could reasonably and realistically see widespread adoption as a routine method for water quality assessment.
Collapse
Affiliation(s)
- Hannah R Safford
- Department of Civil and Environmental Engineering, University of California Davis, 2001 Ghausi Hall, 480 Bainer Hall Drive, 95616, Davis, CA, United States
| | - Heather N Bischel
- Department of Civil and Environmental Engineering, University of California Davis, 2001 Ghausi Hall, 480 Bainer Hall Drive, 95616, Davis, CA, United States.
| |
Collapse
|
16
|
Props R, Rubbens P, Besmer M, Buysschaert B, Sigrist J, Weilenmann H, Waegeman W, Boon N, Hammes F. Detection of microbial disturbances in a drinking water microbial community through continuous acquisition and advanced analysis of flow cytometry data. WATER RESEARCH 2018; 145:73-82. [PMID: 30121434 DOI: 10.1016/j.watres.2018.08.013] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2018] [Revised: 07/26/2018] [Accepted: 08/06/2018] [Indexed: 06/08/2023]
Abstract
Detecting disturbances in microbial communities is an important aspect of managing natural and engineered microbial communities. Here, we implemented a custom-built continuous staining device in combination with real-time flow cytometry (RT-FCM) data acquisition, which, combined with advanced FCM fingerprinting methods, presents a powerful new approach to track and quantify disturbances in aquatic microbial communities. Through this new approach we were able to resolve various natural community and single-species microbial contaminations in a flow-through drinking water reactor. Next to conventional FCM metrics, we applied metrics from a recently developed fingerprinting technique in order to gain additional insight into the microbial dynamics during these contamination events. Importantly, we found that multiple community FCM metrics based on different statistical approaches were required to fully characterize all contaminations. Furthermore we found that for accurate cell concentration measurements and accurate inference from the FCM metrics (coefficient of variation ≤ 5%), at least 1000 cells should be measured, which makes the achievable temporal resolution a function of the prevalent bacterial concentration in the system-of-interest. The integrated RT-FCM acquisition and analysis approach presented herein provides a considerable improvement in the temporal resolution by which microbial disturbances can be observed and simultaneously provides a multi-faceted toolset to characterize such disturbances.
Collapse
Affiliation(s)
- Ruben Props
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | - Peter Rubbens
- KERMIT, Department of Data Analysis and Mathematical Modelling, Ghent University, Coupure Links 653, B-9000, Ghent, Belgium
| | - Michael Besmer
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, CH-8600, Duebendorf, Switzerland; Department of Environmental Systems Science, Institute of Biogeochemistry and Pollutant Dynamics, ETH Zürich, Zürich, Switzerland
| | - Benjamin Buysschaert
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | - Jurg Sigrist
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, CH-8600, Duebendorf, Switzerland
| | - Hansueli Weilenmann
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, CH-8600, Duebendorf, Switzerland
| | - Willem Waegeman
- KERMIT, Department of Data Analysis and Mathematical Modelling, Ghent University, Coupure Links 653, B-9000, Ghent, Belgium
| | - Nico Boon
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | - Frederik Hammes
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, CH-8600, Duebendorf, Switzerland.
| |
Collapse
|
17
|
Lambrecht J, Schattenberg F, Harms H, Mueller S. Characterizing Microbiome Dynamics - Flow Cytometry Based Workflows from Pure Cultures to Natural Communities. J Vis Exp 2018. [PMID: 30059034 DOI: 10.3791/58033] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
The investigation of pure cultures and monitoring of microbial community dynamics is vital to understand and control natural ecosystems and technical applications driven by microorganisms. Next generation sequencing methods are widely utilized to resolve microbiomes, but they are generally resource and time intensive and deliver mostly qualitative information. Flow cytometric microbiome analysis does not suffer from those disadvantages and can provide relative subcommunity abundances and absolute cell numbers at-line. Although it does not deliver direct phylogenetic information, it can enhance the analysis depth and resolution of sequencing approaches. In sharp contrast to medical applications in both research and routine settings, flow cytometry is still not widely used for microbiome analysis. Missing information on sample preparation and data analysis pipelines may create an entry barrier for the researchers facing microbiome analysis challenges that would often be textbook flow cytometry applications. Here, we present three comprehensive workflows for pure cultures, complex communities in clear medium and complex communities in challenging matrices, respectively. We describe individual sampling and fixation procedures and optimized staining protocols for the respective sample sets. We elaborate the cytometric analysis with a complex research centered and an application focused bench top device, describe the cell sorting procedure and suggest data analysis packages. We furthermore propose important experimental controls and apply the presented workflows to the respective sample sets.
Collapse
Affiliation(s)
- Johannes Lambrecht
- Department of Environmental Microbiology, Helmholtz Centre for Environmental Research - UFZ
| | - Florian Schattenberg
- Department of Environmental Microbiology, Helmholtz Centre for Environmental Research - UFZ
| | - Hauke Harms
- Department of Environmental Microbiology, Helmholtz Centre for Environmental Research - UFZ
| | - Susann Mueller
- Department of Environmental Microbiology, Helmholtz Centre for Environmental Research - UFZ;
| |
Collapse
|
18
|
Mao G, Song Y, Bartlam M, Wang Y. Long-Term Effects of Residual Chlorine on Pseudomonas aeruginosa in Simulated Drinking Water Fed With Low AOC Medium. Front Microbiol 2018; 9:879. [PMID: 29774019 PMCID: PMC5943633 DOI: 10.3389/fmicb.2018.00879] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Accepted: 04/16/2018] [Indexed: 11/17/2022] Open
Abstract
Residual chlorine is often required to remain present in public drinking water supplies during distribution to ensure water quality. It is essential to understand how bacteria respond to long-term chlorine exposure, especially with the presence of assimilable organic carbon (AOC). This study aimed to investigate the effects of chlorination on Pseudomonas aeruginosa in low AOC medium by both conventional plating and culture-independent methods including flow cytometry (FCM) and quantitative PCR (qPCR). In a simulated chlorinated system using a bioreactor, membrane damage and DNA damage were measured by FCM fluorescence fingerprint. The results indicated membrane permeability occurred prior to DNA damage in response to chlorination. A regrowth of P. aeruginosa was observed when the free chlorine concentration was below 0.3 mg/L. The bacterial response to long-term exposure to a constant low level of free chlorine (0.3 mg/L) was subsequently studied in detail. Both FCM and qPCR data showed a substantial reduction during initial exposure (0–16 h), followed by a plateau where the cell concentration remained stable (16–76 h), until finally all bacteria were inactivated with subsequent continuous chlorine exposure (76–124 h). The results showed three-stage inactivation kinetics for P. aeruginosa at a low chlorine level with extended exposure time: an initial fast inactivation stage, a relatively stable middle stage, and a final stage with a slower rate than the initial stage. A series of antibiotic resistance tests suggested long-term exposure to low chlorine level led to the selection of antibiotic-resistant P. aeruginosa. The combined results suggest that depletion of residual chlorine in low AOC medium systems could reactivate P. aeruginosa, leading to a possible threat to drinking water safety.
Collapse
Affiliation(s)
- Guannan Mao
- Key Laboratory of Pollution Processes and Environmental Criteria (Ministry of Education), Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| | - Yuhao Song
- Key Laboratory of Pollution Processes and Environmental Criteria (Ministry of Education), Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| | - Mark Bartlam
- State Key Laboratory of Medicinal Chemical Biology, Nankai University, Tianjin, China.,College of Life Sciences, Nankai University, Tianjin, China
| | - Yingying Wang
- Key Laboratory of Pollution Processes and Environmental Criteria (Ministry of Education), Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| |
Collapse
|