1
|
Matter L, Harland B, Raos B, Svirskis D, Asplund M. Generation of direct current electrical fields as regenerative therapy for spinal cord injury: A review. APL Bioeng 2023; 7:031505. [PMID: 37736015 PMCID: PMC10511262 DOI: 10.1063/5.0152669] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 08/21/2023] [Indexed: 09/23/2023] Open
Abstract
Electrical stimulation (ES) shows promise as a therapy to promote recovery and regeneration after spinal cord injury. ES therapy establishes beneficial electric fields (EFs) and has been investigated in numerous studies, which date back nearly a century. In this review, we discuss the various engineering approaches available to generate regenerative EFs through direct current electrical stimulation and very low frequency electrical stimulation. We highlight the electrode-tissue interface, which is important for the appropriate choice of electrode material and stimulator circuitry. We discuss how to best estimate and control the generated field, which is an important measure for comparability of studies. Finally, we assess the methods used in these studies to measure functional recovery after the injury and treatment. This work reviews studies in the field of ES therapy with the goal of supporting decisions regarding best stimulation strategy and recovery assessment for future work.
Collapse
Affiliation(s)
- Lukas Matter
- Author to whom correspondence should be addressed:
| | - Bruce Harland
- School of Pharmacy, The University of Auckland, NZ 1023 Auckland, New Zealand
| | - Brad Raos
- School of Pharmacy, The University of Auckland, NZ 1023 Auckland, New Zealand
| | - Darren Svirskis
- School of Pharmacy, The University of Auckland, NZ 1023 Auckland, New Zealand
| | | |
Collapse
|
2
|
Tian G, Yang D, Chen C, Duan X, Kim DH, Chen H. Simultaneous Presentation of Dexamethasone and Nerve Growth Factor via Layered Carbon Nanotubes and Polypyrrole to Interface Neural Cells. ACS Biomater Sci Eng 2023; 9:5015-5027. [PMID: 37489848 DOI: 10.1021/acsbiomaterials.3c00593] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/26/2023]
Abstract
The implantation of neural electrodes usually induces acute and chronic inflammation, which can result in the formation of glial scars encapsulating the implanted electrodes and the loss of neurons near the active electrode sites. Local presentation of anti-inflammatory drugs or neural protective factors has been evidenced as an effective strategy to modulate inflammatory responses and promote electrode-neuron integration. Here, a novel delivery system for the simultaneous presentation of both anti-inflammatory drugs (dexamethasone, Dex) and nerve-growth-promoting factors (nerve growth factor, NGF) from the electrode sites was developed via layer-structured carbon nanotubes and conductive polymers. The modified electrodes exhibited higher charge storage capacitance and lower electrochemical impedance compared to unmodified electrodes and electrodes coated with polypyrrole/Dex. Dex released from the functional coating under controlled electrochemical stimulation was able to inhibit the lipopolysaccharide-induced secretion or mRNA transcription of inflammatory cytokines, including nitric oxide, TNF-α, and IL-6 in RAW264.7 cells, and control the activation of cultured astrocytes. In addition, the functional coatings did not show a toxic effect on PC12 cells and primary neural cells but exhibited promoted activities on the adhesion, growth, and neurite extension of neural cells.
Collapse
Affiliation(s)
- Guangzhao Tian
- School of Animal Science and Technology, Guangxi University, Nanning 530004, Guangxi, People's Republic of China
| | - Dan Yang
- School of Animal Science and Technology, Guangxi University, Nanning 530004, Guangxi, People's Republic of China
| | - Chunrong Chen
- School of Animal Science and Technology, Guangxi University, Nanning 530004, Guangxi, People's Republic of China
| | - Xiaoge Duan
- School of Animal Science and Technology, Guangxi University, Nanning 530004, Guangxi, People's Republic of China
| | - Dong-Hwan Kim
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
| | - Hailan Chen
- School of Animal Science and Technology, Guangxi University, Nanning 530004, Guangxi, People's Republic of China
| |
Collapse
|
3
|
Talebian S, Mendes B, Conniot J, Farajikhah S, Dehghani F, Li Z, Bitoque D, Silva G, Naficy S, Conde J, Wallace GG. Biopolymeric Coatings for Local Release of Therapeutics from Biomedical Implants. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2207603. [PMID: 36782094 PMCID: PMC10131825 DOI: 10.1002/advs.202207603] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Indexed: 06/18/2023]
Abstract
The deployment of structures that enable localized release of bioactive molecules can result in more efficacious treatment of disease and better integration of implantable bionic devices. The strategic design of a biopolymeric coating can be used to engineer the optimal release profile depending on the task at hand. As illustrative examples, here advances in delivery of drugs from bone, brain, ocular, and cardiovascular implants are reviewed. These areas are focused to highlight that both hard and soft tissue implants can benefit from controlled localized delivery. The composition of biopolymers used to achieve appropriate delivery to the selected tissue types, and their corresponding outcomes are brought to the fore. To conclude, key factors in designing drug-loaded biopolymeric coatings for biomedical implants are highlighted.
Collapse
Affiliation(s)
- Sepehr Talebian
- School of Chemical and Biomolecular EngineeringThe University of SydneySydneyNSW2006Australia
- Nano Institute (Sydney Nano)The University of SydneySydneyNSW2006Australia
| | - Bárbara Mendes
- ToxOmicsNOVA Medical School|Faculdade de Ciências MédicasNMS|FCMUniversidade Nova de LisboaLisboa1169‐056Portugal
| | - João Conniot
- ToxOmicsNOVA Medical School|Faculdade de Ciências MédicasNMS|FCMUniversidade Nova de LisboaLisboa1169‐056Portugal
| | - Syamak Farajikhah
- School of Chemical and Biomolecular EngineeringThe University of SydneySydneyNSW2006Australia
- Nano Institute (Sydney Nano)The University of SydneySydneyNSW2006Australia
| | - Fariba Dehghani
- School of Chemical and Biomolecular EngineeringThe University of SydneySydneyNSW2006Australia
- Nano Institute (Sydney Nano)The University of SydneySydneyNSW2006Australia
| | - Zhongyan Li
- School of Chemical and Biomolecular EngineeringThe University of SydneySydneyNSW2006Australia
| | - Diogo Bitoque
- ToxOmicsNOVA Medical School|Faculdade de Ciências MédicasNMS|FCMUniversidade Nova de LisboaLisboa1169‐056Portugal
| | - Gabriela Silva
- ToxOmicsNOVA Medical School|Faculdade de Ciências MédicasNMS|FCMUniversidade Nova de LisboaLisboa1169‐056Portugal
| | - Sina Naficy
- School of Chemical and Biomolecular EngineeringThe University of SydneySydneyNSW2006Australia
- Nano Institute (Sydney Nano)The University of SydneySydneyNSW2006Australia
| | - João Conde
- ToxOmicsNOVA Medical School|Faculdade de Ciências MédicasNMS|FCMUniversidade Nova de LisboaLisboa1169‐056Portugal
| | - Gordon G. Wallace
- Intelligent Polymer Research InstituteARC Centre of Excellence for Electromaterials ScienceAIIM FacilityUniversity of WollongongSydneyNSW2522Australia
| |
Collapse
|
4
|
Peña JS, Vazquez M. Harnessing the Neuroprotective Behaviors of Müller Glia for Retinal Repair. FRONT BIOSCI-LANDMRK 2022; 27:169. [PMID: 35748245 PMCID: PMC9639582 DOI: 10.31083/j.fbl2706169] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 04/18/2022] [Accepted: 05/05/2022] [Indexed: 11/29/2022]
Abstract
Progressive and irreversible vision loss in mature and aging adults creates a health and economic burden, worldwide. Despite the advancements of many contemporary therapies to restore vision, few approaches have considered the innate benefits of gliosis, the endogenous processes of retinal repair that precede vision loss. Retinal gliosis is fundamentally driven by Müller glia (MG) and is characterized by three primary cellular mechanisms: hypertrophy, proliferation, and migration. In early stages of gliosis, these processes have neuroprotective potential to halt the progression of disease and encourage synaptic activity among neurons. Later stages, however, can lead to glial scarring, which is a hallmark of disease progression and blindness. As a result, the neuroprotective abilities of MG have remained incompletely explored and poorly integrated into current treatment regimens. Bioengineering studies of the intrinsic behaviors of MG hold promise to exploit glial reparative ability, while repressing neuro-disruptive MG responses. In particular, recent in vitro systems have become primary models to analyze individual gliotic processes and provide a stepping stone for in vivo strategies. This review highlights recent studies of MG gliosis seeking to harness MG neuroprotective ability for regeneration using contemporary biotechnologies. We emphasize the importance of studying gliosis as a reparative mechanism, rather than disregarding it as an unfortunate clinical prognosis in diseased retina.
Collapse
Affiliation(s)
- Juan S. Peña
- Department of Biomedical Engineering, Rutgers, The State
University of New Jersey, Piscataway (08854), New Jersey, USA
| | - Maribel Vazquez
- Department of Biomedical Engineering, Rutgers, The State
University of New Jersey, Piscataway (08854), New Jersey, USA
| |
Collapse
|
5
|
Beygisangchin M, Abdul Rashid S, Shafie S, Sadrolhosseini AR, Lim HN. Preparations, Properties, and Applications of Polyaniline and Polyaniline Thin Films-A Review. Polymers (Basel) 2021; 13:2003. [PMID: 34207392 PMCID: PMC8234317 DOI: 10.3390/polym13122003] [Citation(s) in RCA: 109] [Impact Index Per Article: 27.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 05/28/2021] [Accepted: 05/30/2021] [Indexed: 12/18/2022] Open
Abstract
Polyaniline (PANI) is a famous conductive polymer, and it has received tremendous consideration from researchers in the field of nanotechnology for the improvement of sensors, optoelectronic devices, and photonic devices. PANI is doped easily by different acids and dopants because of its easy synthesis and remarkable environmental stability. This review focuses on different preparation processes of PANI thin film by chemical and physical methods. Several features of PANI thin films, such as their magnetic, redox, and antioxidant, anti-corrosion, and electrical and sensing properties, are discussed in this review. PANI is a highly conductive polymer. Given its unique properties, easy synthesis, low cost, and high environmental stability in various applications such as electronics, drugs, and anti-corrosion materials, it has attracted extensive attention. The most important PANI applications are briefly reviewed at the end of this review.
Collapse
Affiliation(s)
- Mahnoush Beygisangchin
- Material Processing and Technology Laboratory, Institute of Advanced Technology, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia;
- Functional Device Laboratory, Institute of Advanced Technology, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (S.S.); (H.N.L.)
| | - Suraya Abdul Rashid
- Material Processing and Technology Laboratory, Institute of Advanced Technology, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia;
| | - Suhaidi Shafie
- Functional Device Laboratory, Institute of Advanced Technology, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (S.S.); (H.N.L.)
- Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia
| | - Amir Reza Sadrolhosseini
- Magneto-Plasmonic Lab, Laser and Plasma Research Institute, Shahid Beheshti University, Tehran 1983969411, Iran
| | - Hong Ngee Lim
- Functional Device Laboratory, Institute of Advanced Technology, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia; (S.S.); (H.N.L.)
| |
Collapse
|
6
|
Jia M, Rolandi M. Soft and Ion-Conducting Materials in Bioelectronics: From Conducting Polymers to Hydrogels. Adv Healthc Mater 2020; 9:e1901372. [PMID: 31976634 DOI: 10.1002/adhm.201901372] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Revised: 12/17/2019] [Indexed: 12/11/2022]
Abstract
Bioelectronics devices that directly interface with cells and tissue have applications in neural and cardiac stimulation and recording, electroceuticals, and brain machine interfaces for prostheses. The interface between bioelectronic devices and biological tissue is inherently challenging due to the mismatch in both mechanical properties (hard vs soft) and charge carriers (electrons vs ions). In addition to conventional metals and silicon, new materials have bridged this interface, including conducting polymers, carbon-based nanomaterials, as well as ion-conducting polymers and hydrogels. This review provides an update on advances in soft bioelectronic materials for current and future therapeutic applications. Specifically, this review focuses on soft materials that can conduct both electrons and ions, and also deliver drugs and small molecules. The future opportunities and emerging challenges in the field are also highlighted.
Collapse
Affiliation(s)
- Manping Jia
- Department of Electrical and Computer Engineering University of California Santa Cruz CA 94064 USA
| | - Marco Rolandi
- Department of Electrical and Computer Engineering University of California Santa Cruz CA 94064 USA
| |
Collapse
|
7
|
Kleber C, Lienkamp K, Rühe J, Asplund M. Electrochemically Controlled Drug Release from a Conducting Polymer Hydrogel (PDMAAp/PEDOT) for Local Therapy and Bioelectronics. Adv Healthc Mater 2019; 8:e1801488. [PMID: 30835957 DOI: 10.1002/adhm.201801488] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 02/05/2019] [Indexed: 12/27/2022]
Abstract
In this study, the release of fluorescein from a photo-crosslinked conducting polymer hydrogel made from a hydrogel precursor poly(dimethylacrylamide-co-4-methacryloyloxy benzophenone (5%)-co-4-styrenesulfonate (2.5%)) (PDMAAp) and the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) is investigated. Fluorescein, here used as a model for a drug, is actively released through application of an electrical trigger signal. The detected quantity is more than six times higher in comparison to that released from a conventional PEDOT/polysterene sulfonate (PSS) system. Release profiles, drug dose, and timing can be tailored by the application of different trigger signals and pretreatments. To demonstrate that the novel drug release system can be used for a drug relevant for local delivery to a neural interface, experiments are furthermore performed with the anti-inflammatory drug dexamethasone (Dex). The conducting polymer hydrogel facilitates the active release of Dex, in comparison to the previously used PEDOT/Dex. It is suggested that PEDOT/PDMAAp is an interesting alternative for conducting polymer based drug release systems, with the potential to offer more volume for storage, yet retaining the excellent electrochemical properties known for PEDOT electrodes.
Collapse
Affiliation(s)
- Carolin Kleber
- Department of Microsystems Engineering, Albert-Ludwigs University, Freiburg, Germany
- Brainlinks-Braintools, Albert-Ludwigs University, Freiburg, 79110, Germany
| | - Karen Lienkamp
- Department of Microsystems Engineering, Albert-Ludwigs University, Freiburg, Germany
- FIT Freiburg Centre for Interactive Materials and Bioinspired Technologies, Albert-Ludwigs University, Freiburg, Germany
| | - Jürgen Rühe
- Department of Microsystems Engineering, Albert-Ludwigs University, Freiburg, Germany
- Brainlinks-Braintools, Albert-Ludwigs University, Freiburg, 79110, Germany
- FIT Freiburg Centre for Interactive Materials and Bioinspired Technologies, Albert-Ludwigs University, Freiburg, Germany
| | - Maria Asplund
- Department of Microsystems Engineering, Albert-Ludwigs University, Freiburg, Germany
- Brainlinks-Braintools, Albert-Ludwigs University, Freiburg, 79110, Germany
| |
Collapse
|
8
|
Evaluation of drug loading capacity and release characteristics of PEDOT/naproxen system: Effect of doping ions. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.09.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
9
|
Rajnicek AM, Zhao Z, Moral-Vico J, Cruz AM, McCaig CD, Casañ-Pastor N. Controlling Nerve Growth with an Electric Field Induced Indirectly in Transparent Conductive Substrate Materials. Adv Healthc Mater 2018; 7:e1800473. [PMID: 29975820 DOI: 10.1002/adhm.201800473] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Revised: 06/05/2018] [Indexed: 11/05/2022]
Abstract
Innovative neurostimulation therapies require improved electrode materials, such as poly(3,4-ethylenedioxythiophene) (PEDOT) polymers or IrOx mixed ionic-electronic conductors and better understanding of how their electrochemistry influences nerve growth. Amphibian neurons growing on transparent films of electronic (metal) conductors and electronic-ionic conductors (polymers and semiconducting oxides) are monitored. Materials are not connected directly to the power supply, but a dipole is created wirelessly within them by electrodes connected to the culture medium in which they are immersed. Without electrical stimulation neurons grow on gold, platinum, PEDOT-polystyrene sulfonate (PEDOT-PSS), IrOx , and mixed oxide (Ir-Ti)Ox , but growth is not related to surface texture or hydrophilicity. Stimulation induces a dipole in all conductive materials, but neurons grow differently on electronic conductors and mixed-valence mixed-ionic conductors. Stimulation slows, but steers neurite extension on gold but not on platinum. The rate and direction of neurite growth on PEDOT-PSS resemble that on glass, but on IrOx and (Ir-Ti)Ox neurites grow faster and in random directions. This suggests electrochemical changes induced in these materials control growth speed and direction selectively. Evidence that the electric dipole induced in conductive material controls nerve growth will impact electrotherapies exploiting wireless stimulation of implanted material arrays, even where transparency is required.
Collapse
Affiliation(s)
- Ann M. Rajnicek
- School of Medicine, Medical Sciences and Nutrition; Institute of Medical Sciences; University of Aberdeen; Aberdeen AB25 2ZD UK
| | - Zhiqiang Zhao
- School of Medicine, Medical Sciences and Nutrition; Institute of Medical Sciences; University of Aberdeen; Aberdeen AB25 2ZD UK
| | - Javier Moral-Vico
- Instituto de Ciencia de Materiales de Barcelona; CSIC; Campus de la Universidad Autónoma de Barcelona; E-08193 Barcelona Spain
| | - Ana M. Cruz
- Instituto de Ciencia de Materiales de Barcelona; CSIC; Campus de la Universidad Autónoma de Barcelona; E-08193 Barcelona Spain
| | - Colin D. McCaig
- School of Medicine, Medical Sciences and Nutrition; Institute of Medical Sciences; University of Aberdeen; Aberdeen AB25 2ZD UK
| | - Nieves Casañ-Pastor
- Instituto de Ciencia de Materiales de Barcelona; CSIC; Campus de la Universidad Autónoma de Barcelona; E-08193 Barcelona Spain
| |
Collapse
|
10
|
Abstract
Polyimide based shaft electrodes were coated with a bioresorbable layer to stiffen them for intracortical insertion and to reduce the mechanical mismatch between the target tissue and the implanted device after degradation of the coating. Molten saccharose was used as coating material. In a proof-of-concept study, the electrodes were implanted into the cortex of Wistar rats and the insertion forces during implantation were recorded. Electrochemical impedance spectroscopy was performed immediately after implantation and up to 13 weeks after implantation to monitor the tissue response to the implanted electrodes. The recorded spectra were modeled with an equivalent circuit to differentiate the influence of the single components. In one rat, a peak in the encapsulation resistance was observable after two weeks of implantation, indicating the peak of the acute inflammatory response. In another rat, the lowest resistances were observed after four weeks, indicating the termination of the acute inflammatory response. Multiunit activity was recorded with an adequate signal to noise ratio to allow spike sorting. Histology was performed after 7, 45 and 201 days of implantation. The results showed the highest tissue reaction after 45 days and confirmed impedance data that acute inflammatory reactions terminate over time.
Collapse
|
11
|
Kleber C, Bruns M, Lienkamp K, Rühe J, Asplund M. An interpenetrating, microstructurable and covalently attached conducting polymer hydrogel for neural interfaces. Acta Biomater 2017; 58:365-375. [PMID: 28578108 DOI: 10.1016/j.actbio.2017.05.056] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 05/19/2017] [Accepted: 05/30/2017] [Indexed: 01/25/2023]
Abstract
This study presents a new conducting polymer hydrogel (CPH) system, consisting of the synthetic hydrogel P(DMAA-co-5%MABP-co-2,5%SSNa) and the conducting polymer (CP) poly(3,4-ethylenedioxythiophene) (PEDOT), intended as coating material for neural interfaces. The composite material can be covalently attached to the surface electrode, can be patterned by a photolithographic process to influence selected electrode sites only and forms an interpenetrating network. The hybrid material was characterized using cyclic voltammetry (CV), impedance spectroscopy (EIS) and X-ray photoelectron spectroscopy (XPS), which confirmed a homogeneous distribution of PEDOT throughout all CPH layers. The CPH exhibited a 2,5 times higher charge storage capacity (CSC) and a reduced impedance when compared to the bare hydrogel. Electrochemical stability was proven over at least 1000 redox cycles. Non-toxicity was confirmed using an elution toxicity test together with a neuroblastoma cell-line. The described material shows great promise for surface modification of neural probes making it possible to combine the beneficial properties of the hydrogel with the excellent electronic properties necessary for high quality neural microelectrodes. STATEMENT OF SIGNIFICANCE Conductive polymer hydrogels have emerged as a promising new class of materials to functionalize electrode surfaces for enhanced neural interfaces and drug delivery. Common weaknesses of such systems are delamination from the connection surface, and the lack of suitable patterning methods for confining the gel to the selected electrode site. Various studies have reported on conductive polymer hydrogels addressing one of these challenges. In this study we present a new composite material which offers, for the first time, the unique combination of properties: it can be covalently attached to the substrate, forms an interpenetrating network, shows excellent electrical properties and can be patterned via UV-irradiation through a structured mask.
Collapse
Affiliation(s)
- Carolin Kleber
- BrainLinks-BrainTools Center, University of Freiburg, Germany; Department of Microsystems Engineering (IMTEK), University of Freiburg, Germany.
| | - Michael Bruns
- Institute for Applied Materials (IAM) and Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Karen Lienkamp
- Department of Microsystems Engineering (IMTEK), University of Freiburg, Germany
| | - Jürgen Rühe
- BrainLinks-BrainTools Center, University of Freiburg, Germany; Department of Microsystems Engineering (IMTEK), University of Freiburg, Germany
| | - Maria Asplund
- BrainLinks-BrainTools Center, University of Freiburg, Germany; Department of Microsystems Engineering (IMTEK), University of Freiburg, Germany
| |
Collapse
|
12
|
Boehler C, Kleber C, Martini N, Xie Y, Dryg I, Stieglitz T, Hofmann U, Asplund M. Actively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study. Biomaterials 2017; 129:176-187. [DOI: 10.1016/j.biomaterials.2017.03.019] [Citation(s) in RCA: 86] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2016] [Revised: 03/08/2017] [Accepted: 03/12/2017] [Indexed: 10/20/2022]
|
13
|
Aqrawe Z, Montgomery J, Travas-Sejdic J, Svirskis D. Conducting Polymers as Electrode Coatings for Neuronal Multi-electrode Arrays. Trends Biotechnol 2017; 35:93-95. [DOI: 10.1016/j.tibtech.2016.06.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2016] [Revised: 06/16/2016] [Accepted: 06/20/2016] [Indexed: 10/21/2022]
|
14
|
Boehler C, Oberueber F, Schlabach S, Stieglitz T, Asplund M. Long-Term Stable Adhesion for Conducting Polymers in Biomedical Applications: IrOx and Nanostructured Platinum Solve the Chronic Challenge. ACS APPLIED MATERIALS & INTERFACES 2017; 9:189-197. [PMID: 27936546 DOI: 10.1021/acsami.6b13468] [Citation(s) in RCA: 92] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Conducting polymers (CPs) have frequently been described as outstanding coating materials for neural microelectrodes, providing significantly reduced impedance or higher charge injection compared to pure metals. Usability has until now, however, been limited by poor adhesion of polymers like poly(3,4-ethylenedioxythiophene) (PEDOT) to metallic substrates, ultimately precluding long-term applications. The aim of this study was to overcome this weakness of CPs by introducing two novel adhesion improvement strategies that can easily be integrated with standard microelectrode fabrication processes. Iridium Oxide (IrOx) demonstrated exceptional stability for PEDOT coatings, resulting in polymer survival over 10 000 redox cycles and 110 days under accelerated aging conditions at 60 °C. Nanostructured Pt was furthermore introduced as a purely mechanical adhesion promoter providing 10-fold adhesion improvement compared to smooth Pt substrates by simply altering the morphology of Pt. This layer can be realized in a very simple process that is compatible with any electrode design, turning nanostructured Pt into a universal adhesion layer for CP coatings. By the introduction of these adhesion-promoting strategies, the weakness of CP-based neural probes can ultimately be eliminated and true long-term stable use of PEDOT on neural probes will be possible in future electrode generations.
Collapse
Affiliation(s)
- Christian Boehler
- BrainLinks-BrainTools Center & Department of Microsystems Engineering (IMTEK), University of Freiburg , Georges-Koehler-Allee 102, 79110 Freiburg, Germany
| | - Felix Oberueber
- BrainLinks-BrainTools Center & Department of Microsystems Engineering (IMTEK), University of Freiburg , Georges-Koehler-Allee 102, 79110 Freiburg, Germany
| | - Sabine Schlabach
- Institute for Applied Materials (IAM) and Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT) , Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Thomas Stieglitz
- BrainLinks-BrainTools Center & Department of Microsystems Engineering (IMTEK), University of Freiburg , Georges-Koehler-Allee 102, 79110 Freiburg, Germany
| | - Maria Asplund
- BrainLinks-BrainTools Center & Department of Microsystems Engineering (IMTEK), University of Freiburg , Georges-Koehler-Allee 102, 79110 Freiburg, Germany
| |
Collapse
|
15
|
Torregrosa T, Koppes RA. Bioelectric Medicine and Devices for the Treatment of Spinal Cord Injury. Cells Tissues Organs 2016; 202:6-22. [PMID: 27701161 DOI: 10.1159/000446698] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/09/2016] [Indexed: 11/19/2022] Open
Abstract
Recovery of motor control is paramount for patients living with paralysis following spinal cord injury (SCI). While a cure or regenerative intervention remains on the horizon for the treatment of SCI, a number of neuroprosthetic devices have been employed to treat and mitigate the symptoms of paralysis associated with injuries to the spinal column and associated comorbidities. The recent success of epidural stimulation to restore voluntary motor function in the lower limbs of a small cohort of patients has breathed new life into the promise of electric-based medicine. Recently, a number of new organic and inorganic electronic devices have been developed for brain-computer interfaces to bypass the injury, for neurorehabilitation, bladder and bowel control, and the restoration of motor or sensory control. Herein, we discuss the recent advances in neuroprosthetic devices for treating SCI and highlight future design needs for closed-loop device systems.
Collapse
|
16
|
The importance of the film structure during self-powered ibuprofen salicylate drug release from polypyrrole electrodeposited on AZ31 Mg. J Solid State Electrochem 2016. [DOI: 10.1007/s10008-016-3288-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
17
|
A Simple Approach for Molecular Controlled Release based on Atomic Layer Deposition Hybridized Organic-Inorganic Layers. Sci Rep 2016; 6:19574. [PMID: 26791399 PMCID: PMC4726427 DOI: 10.1038/srep19574] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Accepted: 12/11/2015] [Indexed: 11/09/2022] Open
Abstract
On-demand release of bioactive substances with high spatial and temporal control offers ground-breaking possibilities in the field of life sciences. However, available strategies for developing such release systems lack the possibility of combining efficient control over release with adequate storage capability in a reasonably compact system. In this study we present a new approach to target this deficiency by the introduction of a hybrid material. This organic-inorganic material was fabricated by atomic layer deposition of ZnO into thin films of polyethylene glycol, forming the carrier matrix for the substance to be released. Sub-surface growth mechanisms during this process converted the liquid polymer into a solid, yet water-soluble, phase. This layer permits extended storage for various substances within a single film of only a few micrometers in thickness, and hence demands minimal space and complexity. Improved control over release of the model substance Fluorescein was achieved by coating the hybrid material with a conducting polymer film. Single dosage and repetitive dispensing from this system was demonstrated. Release was controlled by applying a bias potential of ±0.5 V to the polymer film enabling or respectively suppressing the expulsion of the model drug. In vitro tests showed excellent biocompatibility of the presented system.
Collapse
|
18
|
Hofmann UG, Krüger J. The chronic challenge-new vistas on long-term multisite contacts to the central nervous system. FRONTIERS IN NEUROENGINEERING 2015; 8:3. [PMID: 25852537 PMCID: PMC4364247 DOI: 10.3389/fneng.2015.00003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/18/2015] [Accepted: 02/27/2015] [Indexed: 01/16/2023]
Affiliation(s)
- Ulrich G Hofmann
- Section for Neuroelectronic Systems, Clinic for Neurosurgery, Albert-Ludwigs-University Freiburg Freiburg, Germany ; Cluster of Excellence "BrainLinks-BrainTools" EXC 1086 Freiburg, Germany
| | - Jürgen Krüger
- AG Hirnforschung, Universität Freiburg Freiburg, Germany
| |
Collapse
|
19
|
Aregueta-Robles UA, Woolley AJ, Poole-Warren LA, Lovell NH, Green RA. Organic electrode coatings for next-generation neural interfaces. FRONTIERS IN NEUROENGINEERING 2014; 7:15. [PMID: 24904405 PMCID: PMC4034607 DOI: 10.3389/fneng.2014.00015] [Citation(s) in RCA: 141] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Accepted: 05/06/2014] [Indexed: 01/05/2023]
Abstract
Traditional neuronal interfaces utilize metallic electrodes which in recent years have reached a plateau in terms of the ability to provide safe stimulation at high resolution or rather with high densities of microelectrodes with improved spatial selectivity. To achieve higher resolution it has become clear that reducing the size of electrodes is required to enable higher electrode counts from the implant device. The limitations of interfacing electrodes including low charge injection limits, mechanical mismatch and foreign body response can be addressed through the use of organic electrode coatings which typically provide a softer, more roughened surface to enable both improved charge transfer and lower mechanical mismatch with neural tissue. Coating electrodes with conductive polymers or carbon nanotubes offers a substantial increase in charge transfer area compared to conventional platinum electrodes. These organic conductors provide safe electrical stimulation of tissue while avoiding undesirable chemical reactions and cell damage. However, the mechanical properties of conductive polymers are not ideal, as they are quite brittle. Hydrogel polymers present a versatile coating option for electrodes as they can be chemically modified to provide a soft and conductive scaffold. However, the in vivo chronic inflammatory response of these conductive hydrogels remains unknown. A more recent approach proposes tissue engineering the electrode interface through the use of encapsulated neurons within hydrogel coatings. This approach may provide a method for activating tissue at the cellular scale, however, several technological challenges must be addressed to demonstrate feasibility of this innovative idea. The review focuses on the various organic coatings which have been investigated to improve neural interface electrodes.
Collapse
Affiliation(s)
| | - Andrew J. Woolley
- Graduate School of Biomedical Engineering, University of New South WalesSydney, NSW, Australia
- School of Medicine, University of Western SydneySydney, NSW, Australia
| | - Laura A. Poole-Warren
- Graduate School of Biomedical Engineering, University of New South WalesSydney, NSW, Australia
| | - Nigel H. Lovell
- Graduate School of Biomedical Engineering, University of New South WalesSydney, NSW, Australia
| | - Rylie A. Green
- Graduate School of Biomedical Engineering, University of New South WalesSydney, NSW, Australia
| |
Collapse
|