1
|
Bischoff M, Khalil DA, Frisch S, Bäcker CM, Peters S, Friedrich C, Tippelt S, Kortmann RD, Bison B, Müller HL, Timmermann B. Outcome After Modern Proton Beam Therapy in Childhood Craniopharyngioma: Results of the Prospective Registry Study KiProReg. Int J Radiat Oncol Biol Phys 2024; 120:137-148. [PMID: 38492813 DOI: 10.1016/j.ijrobp.2024.03.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 02/24/2024] [Accepted: 03/10/2024] [Indexed: 03/18/2024]
Abstract
PURPOSE Craniopharyngiomas (CPs) are rare tumors of the sellar region often leading to significant comorbidities due to their close proximity to critical structures. The aim of this study was to analyze survival outcome and late toxicities after surgery and proton beam therapy (PBT) in childhood CPs. METHODS AND MATERIALS Within the prospective registry study "KiProReg" (DRKS0000536), data of 74 childhood patients with CP, receiving PBT between August 2013 to June 2022 were eligible. Late toxicities were analyzed according to the grading system of the Common Terminology Criteria for Adverse Events, version 4.0. RESULTS Median follow-up since first diagnosis was 4.3 years (range, 0.8-14.7). In addition, 75.7% of patients received PBT at time of disease progression or recurrence, whereas 24.3% as part of their primary therapy (definitive or adjuvant). Predominantly (85.1%), pencil beam scanning technique was used. The median total dose and initial tumor volume were 5400 cGy relative biologic effectiveness (RBE) and 17.64 cm³ (range, 3.07-300.59), respectively. The estimated (±SE) 3-year overall survival, progression-free, and cystic failure-free survival rate after PBT were 98.2% (±1.7), 94.7% (±3.0), and 76.8% (±5.4), respectively. All local failures (n = 3) were in-field relapses necessitating intervention and occurred exclusively in patients receiving PBT at progression or recurrence. Early cystic enlargements after PBT were typically asymptomatic and self-limiting. Fatigue, headaches, vision disorders, obesity, and endocrinopathies were the predominant late toxicities. No high-grade (≥3) new-onset visual impairment or cognitive deterioration occurred compared with baseline. The presence of cognitive impairments at the end of follow-up correlated with size of the planning target volume (P = .034), Dmean dose to the temporal lobes (P = .032, P = .045) and the number of surgical interventions before PBT (P = .029). CONCLUSIONS Our findings demonstrate favorable local control rates using modern PBT with acceptable late toxicities. Cyst growth within 12 months after radiation therapy is typically not associated with tumor progression. Longer follow-up must be awaited to confirm results.
Collapse
Affiliation(s)
- Martin Bischoff
- Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Centre (WTZ), Essen, Germany; Department of Radiation Oncology, Ruhr-University Bochum, Medical Faculty, Marien Hospital, Herne, Germany.
| | - Dalia Ahmad Khalil
- Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Centre (WTZ), Essen, Germany
| | - Sabine Frisch
- Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Centre (WTZ), Essen, Germany
| | - Claus M Bäcker
- West German Proton Therapy Centre Essen (WPE), West German Cancer Centre (WTZ), Essen, Germany
| | - Sarah Peters
- Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Centre (WTZ), Essen, Germany
| | - Carsten Friedrich
- Department of Pediatrics and Pediatric Hematology/Oncology, University Children's Hospital, Carl von Ossietzky University Oldenburg, Klinikum Oldenburg AöR, Oldenburg, Germany
| | - Stephan Tippelt
- Department of Pediatrics III, Pediatric Oncology and Hematology, University Hospital Essen, Essen, Germany
| | | | - Brigitte Bison
- Diagnostic and Interventional Neuroradiology, Faculty of Medicine, University of Augsburg, Augsburg, Germany
| | - Hermann L Müller
- Department of Pediatrics and Pediatric Hematology/Oncology, University Children's Hospital, Carl von Ossietzky University Oldenburg, Klinikum Oldenburg AöR, Oldenburg, Germany
| | - Beate Timmermann
- Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Centre (WTZ), Essen, Germany; German Cancer Consortium (DKTK), Essen/Düsseldorf, University Hospital Essen, Essen, Germany
| |
Collapse
|
2
|
Yilmaz MT, Sari SY, Zorlu F, Yazici G. External Beam Radiotherapy in the Management of Uveal Melanoma. Curr Treat Options Oncol 2024; 25:932-951. [PMID: 38869695 PMCID: PMC11236855 DOI: 10.1007/s11864-024-01212-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/25/2024] [Indexed: 06/14/2024]
Abstract
OPINION STATEMENT Uveal melanoma is the most common primary ocular tumor in adults. With the evidence demonstrating that episcleral plaque brachytherapy (EPB) has similar survival rates as enucleation in the Collaborative Ocular Melanoma Study (COMS), eye-sparing treatments have come to the fore today. External radiotherapy techniques (proton beam radiotherapy and stereotactic radiosurgery/fractionated stereotactic radiosurgery) are an important treatment option for globe-sparing treatments. There are no prospective randomized trials comparing these techniques; however, retrospective series, meta-analyses, and reviews indicate that these EPB and external radiotherapy techniques are equal. With this review, we aimed to examine the external radiotherapy techniques used in the treatment of uveal melanoma in detail with reference to the current literature.
Collapse
Affiliation(s)
- Melek Tugce Yilmaz
- Hacettepe University Faculty of Medicine, Department of Radiation Oncology, Ankara, Turkey
| | - Sezin Yuce Sari
- Hacettepe University Faculty of Medicine, Department of Radiation Oncology, Ankara, Turkey
| | - Faruk Zorlu
- Hacettepe University Faculty of Medicine, Department of Radiation Oncology, Ankara, Turkey
| | - Gozde Yazici
- Hacettepe University Faculty of Medicine, Department of Radiation Oncology, Ankara, Turkey.
| |
Collapse
|
3
|
Chou CY, Tsai TS, Huang HC, Wang CC, Lee SH, Hsu SM. Utilizing collimated aperture with proton pencil beam scanning (PBS) for stereotactic radiotherapy. J Appl Clin Med Phys 2024; 25:e14362. [PMID: 38669175 PMCID: PMC11244669 DOI: 10.1002/acm2.14362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 01/22/2024] [Accepted: 03/29/2024] [Indexed: 04/28/2024] Open
Abstract
PURPOSE Proton stereotactic radiosurgery (PSRS) has emerged as an innovative proton therapy modality aimed at achieving precise dose delivery with minimal impact on healthy tissues. This study explores the dosimetric outcomes of PSRS in comparison to traditional intensity-modulated proton therapy (IMPT) by focusing on cases with small target volumes. A custom-made aperture system designed for proton therapy, specifically tailored to small target volumes, was developed and implemented for this investigation. METHODS A prerequisite mechanical validation through an isocentricity test precedes dosimetric assessments, ensuring the seamless integration of mechanical and dosimetry analyses. Five patients were enrolled in the study, including two with choroid melanoma and three with arteriovenous malformations (AVM). Two treatment plans were meticulously executed for each patient, one utilizing a collimated aperture and the other without. Both plans were subjected to robust optimization, maintaining identical beam arrangements and consistent optimization parameters to account for setup errors of 2 mm and range uncertainties of 3.5%. Plan evaluation metrics encompassing the Heterogeneity Index (HI), Paddick Conformity Index (CIPaddick), Gradient Index (GI), and the R50% index to evaluate alterations in low-dose volume distribution. RESULTS The comparative analysis between PSRS and traditional PBS treatment revealed no significant differences in plan outcomes, with both modalities demonstrating comparable target coverage. However, collimated apertures resulted in discernible improvements in dose conformity, dose fall-off, and reduced low-dose volume. CONCLUSIONS This study underscores the advantageous impact of the aperture system on proton therapy, particularly in cases involving small target volumes.
Collapse
Affiliation(s)
- Chen-Yu Chou
- Department of Radiation Oncology, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan (R.O.C)
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei City, Taiwan (R.O.C)
| | - Tsung-Shiau Tsai
- Department of Radiation Oncology, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan (R.O.C)
| | - Hsiao-Chieh Huang
- Department of Radiation Oncology, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan (R.O.C)
| | - Chun-Chieh Wang
- Department of Radiation Oncology, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan (R.O.C)
| | - Shen-Hao Lee
- Department of Radiation Oncology, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan (R.O.C)
| | - Shih-Ming Hsu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei City, Taiwan (R.O.C)
| |
Collapse
|
4
|
Penfold SN, Santos AMC, Penfold M, Shierlaw E, Crain R. Single high-energy arc proton therapy with Bragg peak boost (SHARP). J Med Radiat Sci 2024; 71 Suppl 2:27-36. [PMID: 38400611 PMCID: PMC11011576 DOI: 10.1002/jmrs.769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 02/02/2024] [Indexed: 02/25/2024] Open
Abstract
INTRODUCTION Because of the co-location of critical organs at risk, base of skull tumours require steep dose gradients to achieve the prescribed dosimetric criteria. When available, proton beam therapy (PBT) is often considered a desirable modality for these cases, but in many instances, compromises in target coverage are still required to achieve critical organ at risk (OAR) tolerance doses. A number of techniques have been proposed to further improve the penumbra of PBT. In the current study, we propose a novel, collimator-free treatment planning technique that combines high-energy shoot-through proton beams with conventional Bragg peak spot placement. The small spot size of the high-energy pencil beams provides a sharp penumbra at the target boundary, and the Bragg peak spots provide a higher linear energy transfer (LET) boost to the target centre. METHODS Three base of skull chordoma patients were retrospectively planned with three different PBT treatment planning techniques: (1) conventional intensity-modulated proton therapy (IMPT); (2) high-energy proton arc therapy (HE-PAT); and (3) the novel technique combining HE-PAT and IMPT, referred to as single high-energy arc with Bragg peak boost (SHARP). The Monaco 6 treatment planning system was used. RESULTS SHARP was found to improve the PBT penumbra in the plane perpendicular to the HE-PAT beams. Minimal penumbra differences were observed in the plane of the HE-PAT beams. SHARP reduced dose-averaged LET to surrounding organs at risk. CONCLUSION A novel PBT treatment planning technique was successfully implemented. Initial results indicate the potential for SHARP to improve the penumbra of PBT treatments for base of skull tumours.
Collapse
Affiliation(s)
- Scott N. Penfold
- Australian Bragg Centre for Proton Therapy and ResearchAdelaideSouth AustraliaAustralia
- Department of PhysicsUniversity of AdelaideAdelaideSouth AustraliaAustralia
| | - Alexandre M. C. Santos
- Australian Bragg Centre for Proton Therapy and ResearchAdelaideSouth AustraliaAustralia
- Department of PhysicsUniversity of AdelaideAdelaideSouth AustraliaAustralia
- Radiation OncologyCentral Adelaide Local Health NetworkAdelaideSouth AustraliaAustralia
| | - Melanie Penfold
- Australian Bragg Centre for Proton Therapy and ResearchAdelaideSouth AustraliaAustralia
| | - Emma Shierlaw
- Australian Bragg Centre for Proton Therapy and ResearchAdelaideSouth AustraliaAustralia
- Radiation OncologyCentral Adelaide Local Health NetworkAdelaideSouth AustraliaAustralia
| | - Rosanna Crain
- Australian Bragg Centre for Proton Therapy and ResearchAdelaideSouth AustraliaAustralia
- Radiation OncologyCentral Adelaide Local Health NetworkAdelaideSouth AustraliaAustralia
| |
Collapse
|
5
|
Gray T, Kolano AM, Liu CW, Cho YB, Donaghue J, Chao S, Suh J, Xia P, Farr J. Comprehensive assessment of proton plans with three different beam delivery systems for multiple brain metastases. JOURNAL OF RADIOSURGERY AND SBRT 2024; 9:145-156. [PMID: 39087064 PMCID: PMC11288651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 04/02/2024] [Indexed: 08/02/2024]
Abstract
Purpose To compare plan quality among photon volumetric arc therapy (VMAT), Gamma Knife, and three different proton beam modalities. Methods Fifty-five brain lesions from 20 patients were planned with three different proton spot size ranges of cyclotron-generated proton beams, CPBs (spot size σ: 2.7-7.0 mm), linear accelerator proton beams, LPBs (σ: 2.9-5.5 mm), and linear accelerator proton minibeams, LPMBs (σ: 0.9-3.9 mm), with and without apertures and compared against photon VMAT and Gamma Knife plans. Dose coverage to each lesion for each proton and photon plan was set to 99% of the GTV receiving the prescription (Rx) dose. All proton plans used ±2 mm setup uncertainty and ±2% range uncertainty in robust evaluation to achieve V100%Rx > 95% of the GTV. Apertures were applied to proton beams irradiating tumors <1 cm3 volume and located <2.5 cm depth. Conformity index (CI), gradient index (GI), V12 Gy, V4.5 Gy, and mean brain dose were compared across all plan types. The Wilcoxon signed rank test was utilized to determine statistical significance of dosimetric results compared between photon and proton plans. Results When compared to CPB generated plans, average CI and GI were significantly better for the LPB and LPMB plans. Aperture-based IMPT plans showed improvement from Gamma Knife for all dosimetric metrics. Aperture-based IMPT plans also showed improvement in all dosimetric metrics for shallow tumors (d < 2.5 cm) when compared with non-aperture-based plans. Conclusion The LPB and LPMB stand as excellent alternatives to CPB or photon therapy and significantly increase the preservation of normal tissue.
Collapse
Affiliation(s)
- Tara Gray
- Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Anna Maria Kolano
- Applications of Detectors and Accelerators to Medicine (ADAM) SA, Meyrin, Switzerland
- Advanced Oncotherapy (AVO) plc, London, UK
| | | | | | | | - Samuel Chao
- Cleveland Clinic Foundation, Cleveland, OH, USA
| | - John Suh
- Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Ping Xia
- Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Jonathan Farr
- Applications of Detectors and Accelerators to Medicine (ADAM) SA, Meyrin, Switzerland
- Advanced Oncotherapy (AVO) plc, London, UK
| |
Collapse
|
6
|
Tominaga Y, Suga M, Takeda M, Yamamoto Y, Akagi T, Kato T, Tokumaru S, Yamamoto M, Oita M. Dose-volume comparisons of proton therapy for pencil beam scanning with and without multi-leaf collimator and passive scattering in patients with lung cancer. Med Dosim 2023; 49:13-18. [PMID: 37940436 DOI: 10.1016/j.meddos.2023.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 10/05/2023] [Accepted: 10/06/2023] [Indexed: 11/10/2023]
Abstract
This study evaluated the dose distributions of proton pencil beam scanning (PBS) with/without a multileaf collimator (MLC) compared to passive scattering (PS) for stage I/II lung cancers. Collimated/uncollimated (PBS+/PBS-) and PS plans were created for 20 patients. Internal-clinical-target-volumes (ICTVs) and planning-target-volumes (PTVs) with a 5 mm margin were defined on the gated CTs. Organs-at-risk (OARs) are defined as the normal lungs, spinal cord, esophagus, and heart. The prescribed dose was 66 Gy relative-biological-effectiveness (RBE) in 10 fractions at the isocenter and 50% volume of the ICTVs for the PS and PBS, respectively. We compared the target and OAR dose statistics from the dose volume histograms. The PBS+ group had a significantly better mean PTV conformity index than the PBS- and PS groups. The mean dose sparing for PBS+ was better than those for PBS- and PS. Only the normal lung doses of PBS- were worse than those of PS. The overall performance of the OAR sparing was in the order of PBS+, PBS-, and PS. The PBS+ plan showed significantly better target homogeneity and OAR sparing than the PBS- and PS plans. PBS requires collimating systems to treat lung cancers with the most OAR sparing while maintaining the target coverage.
Collapse
Affiliation(s)
- Yuki Tominaga
- Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Konohana-ku, Osaka 554-0022, Japan.
| | - Masaki Suga
- Hyogo Ion Beam Medical Center, Tatsuno, Hyogo 679-5165, Japan
| | - Mikuni Takeda
- Hyogo Ion Beam Medical Center, Tatsuno, Hyogo 679-5165, Japan
| | - Yuki Yamamoto
- Hyogo Ion Beam Medical Center, Tatsuno, Hyogo 679-5165, Japan
| | - Takashi Akagi
- Hyogo Ion Beam Medical Center, Tatsuno, Hyogo 679-5165, Japan
| | - Takahiro Kato
- Depertment of Radiological Sciences, School of Health Sciences, Fukushima, Medical University, Fukushima 960-1295, Japan; Depertment of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, Koriyama, Fukushima 963-8052, Japan
| | - Sunao Tokumaru
- Hyogo Ion Beam Medical Center, Tatsuno, Hyogo 679-5165, Japan
| | - Michinori Yamamoto
- Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Konohana-ku, Osaka 554-0022, Japan
| | - Masataka Oita
- Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama 700-8558, Japan
| |
Collapse
|
7
|
Winter SF, Vaios EJ, Shih HA, Grassberger C, Parsons MW, Gardner MM, Ehret F, Kaul D, Boehmerle W, Endres M, Dietrich J. Mitigating Radiotoxicity in the Central Nervous System: Role of Proton Therapy. Curr Treat Options Oncol 2023; 24:1524-1549. [PMID: 37728819 DOI: 10.1007/s11864-023-01131-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/08/2023] [Indexed: 09/21/2023]
Abstract
OPINION STATEMENT Central nervous system (CNS) radiotoxicity remains a challenge in neuro-oncology. Dose distribution advantages of protons over photons have prompted increased use of brain-directed proton therapy. While well-recognized among pediatric populations, the benefit of proton therapy among adults with CNS malignancies remains controversial. We herein discuss the role of protons in mitigating late CNS radiotoxicities in adult patients. Despite limited clinical trials, evidence suggests toxicity profile advantages of protons over conventional radiotherapy, including retention of neurocognitive function and brain volume. Modelling studies predict superior dose conformality of protons versus state-of-the-art photon techniques reduces late radiogenic vasculopathies, endocrinopathies, and malignancies. Conversely, potentially higher brain tissue necrosis rates following proton therapy highlight a need to resolve uncertainties surrounding the impact of variable biological effectiveness of protons on dose distribution. Clinical trials comparing best photon and particle-based therapy are underway to establish whether protons substantially improve long-term treatment-related outcomes in adults with CNS malignancies.
Collapse
Affiliation(s)
- Sebastian F Winter
- Department of Neurology and MGH Cancer Center, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
- Department of Neurology and Experimental Neurology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 10117, Berlin, Germany.
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité Junior Clinician Scientist Program, 10117, Berlin, Germany.
| | - Eugene J Vaios
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Helen A Shih
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Clemens Grassberger
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Michael W Parsons
- Department of Psychiatry, Psychology Assessment Center, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Melissa M Gardner
- Department of Psychiatry, Psychology Assessment Center, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Felix Ehret
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité Junior Clinician Scientist Program, 10117, Berlin, Germany
- Department of Radiation Oncology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353, Berlin, Germany
- Charité - Universitätsmedizin Berlin, Berlin, Germany; German Cancer Consortium (DKTK), partner site Berlin, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - David Kaul
- Department of Radiation Oncology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353, Berlin, Germany
- Charité - Universitätsmedizin Berlin, Berlin, Germany; German Cancer Consortium (DKTK), partner site Berlin, and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Wolfgang Boehmerle
- Department of Neurology and Experimental Neurology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 10117, Berlin, Germany
| | - Matthias Endres
- Department of Neurology and Experimental Neurology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 10117, Berlin, Germany
- Center for Stroke Research Berlin, Berlin, Germany
- ExcellenceCluster NeuroCure, Berlin, Germany
- German Center for Neurodegenerative Diseases (DZNE), partner site Berlin, Berlin, Germany
- German Centre for Cardiovascular Research (DZHK), partner site Berlin, Berlin, Germany
| | - Jorg Dietrich
- Department of Neurology and MGH Cancer Center, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
8
|
Sproull M, Wilson E, Miller R, Camphausen K. The Future of Radioactive Medicine. Radiat Res 2023; 200:80-91. [PMID: 37141143 PMCID: PMC10466314 DOI: 10.1667/rade-23-00031.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Accepted: 04/07/2023] [Indexed: 05/05/2023]
Abstract
The discovery of X rays in the late 19th century heralded the beginning of a new age in medicine, and the advent of channeling the power of radiation to diagnose and treat human disease. Radiation has been leveraged in medicine in a multitude of ways and is a critical element of cancer care including screening, diagnosis, surveillance, and interventional treatments. Modern radiotherapy techniques include a multitude of methodologies utilizing both externally and internally delivered radiation from a variety of approaches. This review provides a comprehensive overview of contemporary radiotherapy methodologies, the field of radiopharmaceuticals and theranostics, effects of low dose radiation and highlights the phenomena of fear of exposure to radiation and its impact in modern medicine.
Collapse
Affiliation(s)
- M. Sproull
- Radiation Oncology Branch, National Cancer Institute, Bethesda, Maryland
| | - E. Wilson
- Radiation Oncology Branch, National Cancer Institute, Bethesda, Maryland
| | - R.W. Miller
- Radiation Oncology Branch, National Cancer Institute, Bethesda, Maryland
| | - K. Camphausen
- Radiation Oncology Branch, National Cancer Institute, Bethesda, Maryland
| |
Collapse
|
9
|
Geoghegan T, Patwardhan K, Ying Q, Nelson N, Yu J, Gutierrez A, Hill P, Flynn R, Hyer D. Design, testing and characterization of a proton central axis alignment device for the dynamic collimation system. Biomed Phys Eng Express 2023; 9:10.1088/2057-1976/acdad5. [PMID: 37267924 PMCID: PMC10330655 DOI: 10.1088/2057-1976/acdad5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 06/02/2023] [Indexed: 06/04/2023]
Abstract
Objective. Proton therapy conformity has improved over the years by evolving from passive scattering to spot scanning delivery technologies with smaller proton beam spot sizes. Ancillary collimation devices, such the Dynamic Collimation System (DCS), further improves high dose conformity by sharpening the lateral penumbra. However, as spot sizes are reduced, collimator positional errors play a significant impact on the dose distributions and hence accurate collimator to radiation field alignment is critical.Approach. The purpose of this work was to develop a system to align and verify coincidence between the center of the DCS and the proton beam central axis. The Central Axis Alignment Device (CAAD) is composed of a camera and scintillating screen-based beam characterization system. Within a light-tight box, a 12.3-megapixel camera monitors a P43/Gadox scintillating screen via a 45° first-surface mirror. When a collimator trimmer of the DCS is placed in the uncalibrated center of the field, the proton radiation beam continuously scans a 7×7 cm2square field across the scintillator and collimator trimmer while a 7 s exposure is acquired. From the relative positioning of the trimmer to the radiation field, the true center of the radiation field can be calculated.Main results.The CAAD can calculate the offset between the proton beam radiation central axis and the DCS central axis within 0.054 mm accuracy and 0.075 mm reproducibility.Significance.Using the CAAD, the DCS is now able to be aligned accurately to the proton radiation beam central axis and no longer relies on an x-ray source in the gantry head which is only validated to within 1.0 mm of the proton beam.
Collapse
Affiliation(s)
- Theodore Geoghegan
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Kaustubh Patwardhan
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Qi Ying
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Nicholas Nelson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI, 53705, United States of America
| | - Jen Yu
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N. Kendall Drive, Miami, FL, 33176, United States of America
| | - Alonso Gutierrez
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N. Kendall Drive, Miami, FL, 33176, United States of America
| | - Patrick Hill
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, 600 Highland Avenue, Madison, WI, 53792, United States of America
| | - Ryan Flynn
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Daniel Hyer
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| |
Collapse
|
10
|
Nabha R, De Saint-Hubert M, Marichal J, Esser J, Van Hoey O, Bäumer C, Verbeek N, Struelens L, Sterpin E, Tabury K, Marek L, Granja C, Timmermann B, Vanhavere F. Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy. Phys Med Biol 2023; 68. [PMID: 36821866 DOI: 10.1088/1361-6560/acbe8d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 02/23/2023] [Indexed: 02/25/2023]
Abstract
Objective. The lateral dose fall-off in proton pencil beam scanning (PBS) technique remains the preferred choice for sparing adjacent organs at risk as opposed to the distal edge due to the proton range uncertainties and potentially high relative biological effectiveness. However, because of the substantial spot size along with the scattering in the air and in the patient, the lateral penumbra in PBS can be degraded. Combining PBS with an aperture can result in a sharper dose fall-off, particularly for shallow targets.Approach. The aim of this work was to characterize the radiation fields produced by collimated and uncollimated 100 and 140 MeV proton beams, using Monte Carlo simulations and measurements with a MiniPIX-Timepix detector. The dose and the linear energy transfer (LET) were then coupled with publishedin silicobiophysical models to elucidate the potential biological effects of collimated and uncollimated fields.Main results. Combining an aperture with PBS reduced the absorbed dose in the lateral fall-off and out-of-field by 60%. However, the results also showed that the absolute frequency-averaged LET (LETF) values increased by a maximum of 3.5 keVμm-1in collimated relative to uncollimated fields, while the dose-averaged LET (LETD) increased by a maximum of 7 keVμm-1. Despite the higher LET values produced by collimated fields, the predicted DNA damage yields remained lower, owing to the large dose reduction.Significance. This work demonstrated the dosimetric advantages of combining an aperture with PBS coupled with lower DNA damage induction. A methodology for calculating dose in water derived from measurements with a silicon-based detector was also presented. This work is the first to demonstrate experimentally the increase in LET caused by combining PBS with aperture, and to assess the potential DNA damage which is the initial step in the cascade of events leading to the majority of radiation-induced biological effects.
Collapse
Affiliation(s)
- Racell Nabha
- Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium.,KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
| | - Marijke De Saint-Hubert
- Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | | | - Johannes Esser
- West German Proton Therapy Centre Essen, Essen, Germany.,West German Cancer Center (WTZ), University Hospital Essen, Essen, Germany
| | - Olivier Van Hoey
- Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | - Christian Bäumer
- West German Proton Therapy Centre Essen, Essen, Germany.,West German Cancer Center (WTZ), University Hospital Essen, Essen, Germany.,TU Dortmund University, Department of Physics, Dortmund, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany
| | - Nico Verbeek
- West German Proton Therapy Centre Essen, Essen, Germany.,West German Cancer Center (WTZ), University Hospital Essen, Essen, Germany
| | - Lara Struelens
- Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | - Edmond Sterpin
- KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium.,UCLouvain, Institut de Recherche Expérimentale et Clinique, MIRO Lab, Brussels, Belgium
| | - Kevin Tabury
- Radiobiology Unit, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | | | | | - Beate Timmermann
- West German Proton Therapy Centre Essen, Essen, Germany.,West German Cancer Center (WTZ), University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,Department of Particle Therapy, University Hospital Essen, Essen, Germany
| | - Filip Vanhavere
- Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium.,KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
| |
Collapse
|
11
|
Trofimov AV, Aronow ME, Gragoudas ES, Keane FK, Kim IK, Shih HA, Bhagwat MS. A Systematic Comparison of Dose Distributions Delivered in 125I Plaque Brachytherapy and Proton Radiation Therapy for Ocular Melanoma. Int J Radiat Oncol Biol Phys 2023; 115:501-510. [PMID: 35878716 DOI: 10.1016/j.ijrobp.2022.07.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 07/06/2022] [Accepted: 07/13/2022] [Indexed: 01/11/2023]
Abstract
PURPOSE To characterize dose distributions with 125I plaque brachytherapy compared with proton radiation therapy for ocular melanoma for relevant clinical scenarios, based on tumor base diameter (d), apical height (h), and location. METHODS AND MATERIALS Plaque and proton treatment plans were created for 4 groups of cases: (1) REF: 39 instances of reference midsize circular-base tumor (d = 12 mm, h = 5 mm), in locations varying by retinal clock hours and distance to fovea, optic disc, and corneal limbus; (2) SUP: 25 superiorly located; (3) TEMP: 25 temporal; and (4) NAS: 25 nasally located tumors that were a fixed distance from the fovea but varying in d (6-18 mm) and h (3-11 mm). For both modalities, 111 unique scenarios were characterized in terms of the distance to points of interest, doses delivered to fovea, optic disc, optic nerve at 3 mm posterior to the disc (ON@3mm), lens, and retina. Comparative statistical evaluation was performed with the Mann-Whitney U test. RESULTS Superior dose distributions favored plaque for sparing of (1) fovea in large (d + h ≥ 21 mm) NAS tumors; (2) ON@3mm in REF cases located ≤4 disc diameters from disc, and in NAS overall. Protons achieved superior dose sparing of (1) fovea and optic disc in REF, SUP, and TEMP; (2) ON@3mm in REF >4 disc diameters from disc, and in SUP and TEMP; and (3) the lens center overall and lens periphery in REF ≤6 mm from the corneal limbus, and in TEMP with h = 3 mm. Although protons could completely spare sections of the retina, plaque dose was more target conformal in the high-dose range (50% and 90% of prescription dose). CONCLUSIONS Although comparison between plaque and proton therapy is not straightforward because of the disparity in dose rate, prescriptions, applicators, and delivery techniques, it is possible to identify distinctions between dose distributions, which could help inform decisions by providers and patients.
Collapse
Affiliation(s)
- Alexei V Trofimov
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts.
| | - Mary E Aronow
- Ocular Melanoma Center, Retina Service, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| | - Evangelos S Gragoudas
- Ocular Melanoma Center, Retina Service, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| | - Florence K Keane
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Ivana K Kim
- Ocular Melanoma Center, Retina Service, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts
| | - Helen A Shih
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Mandar S Bhagwat
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
12
|
Behrends C, Bäumer C, Verbeek NG, Wulff J, Timmermann B. Optimization of proton pencil beam positioning in collimated fields. Med Phys 2023; 50:2540-2551. [PMID: 36609847 DOI: 10.1002/mp.16209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 12/24/2022] [Accepted: 12/26/2022] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND The addition of static or dynamic collimator systems to the pencil beam scanning delivery technique increases the number of options for lateral field shaping. The collimator shape needs to be optimized together with the intensity modulation of spots. PURPOSE To minimize the proton field's lateral penumbra by investigating the fundamental relations between spot and collimating aperture edge position. METHODS Analytical approaches describing the effect of spot position on the resulting spot profile are presented. The theoretical description is then compared with Monte Carlo simulations in TOPAS and in the RayStation treatment planning system, as well as with radiochromic film measurements at a clinical proton therapy facility. In the model, one single spot profile is analyzed for various spot positions in air. Further, irradiation setups in water with different energies, the combination with a range shifter, and two-dimensional proton fields were investigated in silico. RESULTS The further the single spot is placed beyond the collimating aperture edge ('overscanning'), the sharper the relative lateral dose fall-off and thus the lateral penumbra. Overscanning up to 5 mm $5\,\text{mm}$ reduced the lateral penumbra by about 20% on average after a propagation of 13 cm $13\,\text{cm}$ in air. This benefit from overscanning is first predicted by the analytical proofs and later verified by simulations and measurements. Corresponding analyses in water confirm the benefit in lateral penumbra with spot position optimization as observed theoretically and in air. The combination of spot overscanning with fluence modulation facilitated an additional improvement. CONCLUSIONS The lateral penumbra of single spots in collimated scanned proton fields can be improved by the method of spot overscanning. This suggests a better sparing of proximal organs at risk in smaller water depths at higher energies, especially in the plateau of the depth dose distribution. All in all, spot overscanning in collimated scanned proton fields offers particular potential in combination with techniques such as fluence modulation or dynamic collimation for optimizing the lateral penumbra to spare normal tissue.
Collapse
Affiliation(s)
- Carina Behrends
- West German Proton Therapy Centre Essen (WPE), Essen, Germany.,Department of Physics, TU Dortmund University, Dortmund, Germany.,West German Cancer Centre (WTZ), University Hospital Essen, Essen, Germany
| | - Christian Bäumer
- West German Proton Therapy Centre Essen (WPE), Essen, Germany.,Department of Physics, TU Dortmund University, Dortmund, Germany.,West German Cancer Centre (WTZ), University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany
| | - Nico Gerd Verbeek
- West German Proton Therapy Centre Essen (WPE), Essen, Germany.,West German Cancer Centre (WTZ), University Hospital Essen, Essen, Germany.,Faculty of Medicine, University of Duisburg-Essen, Essen, Germany
| | - Jörg Wulff
- West German Proton Therapy Centre Essen (WPE), Essen, Germany.,West German Cancer Centre (WTZ), University Hospital Essen, Essen, Germany
| | - Beate Timmermann
- West German Proton Therapy Centre Essen (WPE), Essen, Germany.,West German Cancer Centre (WTZ), University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,Faculty of Medicine, University of Duisburg-Essen, Essen, Germany.,Department of Particle Therapy, University Hospital Essen, Essen, Germany
| |
Collapse
|
13
|
Treatment of ocular tumors through a novel applicator on a conventional proton pencil beam scanning beamline. Sci Rep 2022; 12:4648. [PMID: 35301371 PMCID: PMC8931109 DOI: 10.1038/s41598-022-08440-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 03/03/2022] [Indexed: 11/23/2022] Open
Abstract
Treatment of ocular tumors on dedicated scattering-based proton therapy systems is standard afforded due to sharp lateral and distal penumbras. However, most newer proton therapy centers provide pencil beam scanning treatments. In this paper, we present a pencil beam scanning (PBS)-based ocular treatment solution. The design, commissioning, and validation of an applicator mount for a conventional PBS snout to allow for ocular treatments are given. In contrast to scattering techniques, PBS-based ocular therapy allows for inverse planning, providing planners with additional flexibility to shape the radiation field,
potentially sparing healthy tissues. PBS enables the use of commercial Monte Carlo algorithms resulting in accurate dose calculations in the presence of heterogeneities and fiducials. The validation consisted of small field dosimetry measurements of point doses, depth doses, and lateral profiles relevant to ocular therapy. A comparison of beam properties achieved through the applicator against published literature is presented. We successfully showed the feasibility of PBS-based ocular treatments.
Collapse
|
14
|
Wulff J, Koska B, Janson M, Bäumer C, Denker A, Geismar D, Gollrad J, Timmermann B, Heufelder J. Technical Note: Impact of Beam Properties for Uveal Melanoma Proton Therapy - An In-Silico Planning Study. Med Phys 2022; 49:3481-3488. [PMID: 35218037 DOI: 10.1002/mp.15573] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 02/19/2022] [Accepted: 02/21/2022] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To evaluate the impact of beam quality in terms of distal fall-off (DFO, 90% to 10%) and lateral penumbra (LP, 80% to 20%) of single beam ocular proton treatment (OPT) and to derive resulting ideal requirements for future systems. METHODS Nine different beam models with DFO varying between 1 mm and 4 mm and LP between 1 mm and 4 mm were created. Beam models were incorporated into the RayStation with RayOcular TPS version 10 B (RaySearch Laboratories, Sweden). Each beam model was applied for eight typical clinical cases, covering different sizes and locations of uveal melanoma. Plans with and without an additional wedge were created, resulting in 117 plans with a total prescribed median dose of 60 Gy(RBE) to the CTV. Treatment plans were analyzed in terms of V20-V80 penumbra volume, D1 (dose to 1% of the volume) for optic disc and macula, optic nerve V30 (volume receiving 30 Gy(RBE), i.e. 50% of prescription), as well as average dose to lens and ciliary body. A LP dependent aperture margin was based on estimated uncertainties, ranging from 1.7 mm to 4.0 mm. RESULTS V20-V80 showed a strong influence by LP, while DFO was less relevant. The optic disc D1 reached an extra dose of up to 3000 cGy(RBE), comparing the defined technical limit of DFO = LP = 1 mm with DFO = 3 mm/ LP = 4 mm. The latter may result from a pencil-beam scanning (PBS) system with static apertures. Plans employing a wedge showed an improvement for organs at risk (OAR) sparing. CONCLUSION Plan quality is strongly influenced by initial beam parameters. The impact of LP is more pronounced when compared to DFO. The latter becomes important in the treatment of posterior tumors near the macula, optic disc or optic nerve. The plan quality achieved by dedicated OPT nozzles in single- or double-scattering design might not be achievable with modified PBS systems. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- J Wulff
- West German Proton Therapy Centre Essen (WPE), Essen, Germany.,University Hospital Essen, Essen, Germany.,West German Cancer Centre (WTZ), Essen, Germany
| | - B Koska
- West German Proton Therapy Centre Essen (WPE), Essen, Germany.,University Hospital Essen, Essen, Germany.,West German Cancer Centre (WTZ), Essen, Germany
| | - M Janson
- RaySearch Laboratories, Stockholm, Sweden
| | - C Bäumer
- West German Proton Therapy Centre Essen (WPE), Essen, Germany.,University Hospital Essen, Essen, Germany.,West German Cancer Centre (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,TU Dortmund University, Dortmund, Germany
| | - A Denker
- Helmholtz-Zentrum Berlin für Materialien und Energie, Protonentherapie, Germany.,Beuth-Hochschule für Technik, Berlin, Germany
| | - D Geismar
- West German Proton Therapy Centre Essen (WPE), Essen, Germany.,University Hospital Essen, Essen, Germany.,West German Cancer Centre (WTZ), Essen, Germany.,Department of Particle Therapy, Essen, Germany
| | - J Gollrad
- Charité - Universitätsmedizin Berlin, Department of Radiation Oncology and Radiotherapy, Berlin, Germany
| | - B Timmermann
- West German Proton Therapy Centre Essen (WPE), Essen, Germany.,University Hospital Essen, Essen, Germany.,West German Cancer Centre (WTZ), Essen, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,Department of Particle Therapy, Essen, Germany
| | - J Heufelder
- Charité - Universitätsmedizin Berlin, Department of Ophthalmology, Berlin, Germany.,Charité - Universitätsmedizin Berlin, BerlinProtonen am Helmholtz-Zentrum für Materialien und Energie, Berlin, Germany
| |
Collapse
|
15
|
Vidal M, Moignier C, Patriarca A, Sotiropoulos M, Schneider T, De Marzi L. Future technological developments in proton therapy - A predicted technological breakthrough. Cancer Radiother 2021; 25:554-564. [PMID: 34272182 DOI: 10.1016/j.canrad.2021.06.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 06/18/2021] [Indexed: 12/13/2022]
Abstract
In the current spectrum of cancer treatments, despite high costs, a lack of robust evidence based on clinical outcomes or technical and radiobiological uncertainties, particle therapy and in particular proton therapy (PT) is rapidly growing. Despite proton therapy being more than fifty years old (first proposed by Wilson in 1946) and more than 220,000 patients having been treated with in 2020, many technological challenges remain and numerous new technical developments that must be integrated into existing systems. This article presents an overview of on-going technical developments and innovations that we felt were most important today, as well as those that have the potential to significantly shape the future of proton therapy. Indeed, efforts have been done continuously to improve the efficiency of a PT system, in terms of cost, technology and delivery technics, and a number of different developments pursued in the accelerator field will first be presented. Significant developments are also underway in terms of transport and spatial resolution achievable with pencil beam scanning, or conformation of the dose to the target: we will therefore discuss beam focusing and collimation issues which are important parameters for the development of these techniques, as well as proton arc therapy. State of the art and alternative approaches to adaptive PT and the future of adaptive PT will finally be reviewed. Through these overviews, we will finally see how advances in these different areas will allow the potential for robust dose shaping in proton therapy to be maximised, probably foreshadowing a future era of maturity for the PT technique.
Collapse
Affiliation(s)
- M Vidal
- Centre Antoine-Lacassagne, Fédération Claude Lalanne, 227, avenue de la Lanterne, 06200 Nice, France
| | - C Moignier
- Centre François Baclesse, Department of Medical Physics, Centre de protonthérapie de Normandie, 14000 Caen, France
| | - A Patriarca
- Institut Curie, PSL Research University, Radiation oncology department, Centre de protonthérapie d'Orsay, Campus universitaire, bâtiment 101, 91898 Orsay, France
| | - M Sotiropoulos
- Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation radiobiologie et cancer, 91400 Orsay, France
| | - T Schneider
- Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation radiobiologie et cancer, 91400 Orsay, France
| | - L De Marzi
- Institut Curie, PSL Research University, Radiation oncology department, Centre de protonthérapie d'Orsay, Campus universitaire, bâtiment 101, 91898 Orsay, France; Institut Curie, PSL Research University, University Paris Saclay, Inserm LITO, Campus universitaire, 91898 Orsay, France.
| |
Collapse
|