1
|
Walle N, Doerr AA, Peters B, Laschke MW, Menger MD, Schmidt PH, Meyer MR, Schaefer N. Are the postmortem concentration changes of the synthetic cannabinoid cumyl-5F-P7AICA and its N-pentanoic acid metabolite dependent on the environmental conditions? - A systematic study following pulmonary administration to pigs. Toxicol Lett 2024; 401:170-180. [PMID: 39395683 DOI: 10.1016/j.toxlet.2024.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Revised: 09/13/2024] [Accepted: 10/07/2024] [Indexed: 10/14/2024]
Abstract
The number of fatal cases involving synthetic cannabinoids (SCs) is increasing. However, interpretation of postmortem (PM) toxicological findings is challenging, due to unknown PM intervals and possible redistribution processes or instabilities. Only sparse data on SCs are available. Therefore, a controlled pig study was performed to determine the PM stability of cumyl-5F-P7AICA under different environmental conditions. Ten pigs inhalatively received 200 µg/kg body weight cumyl-5F-P7AICA each. Six hours later, they were euthanized and biopsies of the main tissues and body fluids were taken. Animals were stored in air or water (n=5 each) and samples were repeatedly taken for three days. Quantification of cumyl-5F-P7AICA and its N-pentanoic acid metabolite (NPA) was performed using standard addition or a fully validated method (blood) followed by LC-MS/MS. Time-dependent concentration changes of cumyl-5F-P7AICA were observed in liver, bile fluid and muscle specimens at both conditions. Concentrations of NPA only changed considerably in duodenum content of animals stored in air. Environment-dependent concentrations changes were only observed for cumyl-5F-P7AICA in kidney and the NPA metabolite in duodenum content. Overall, cumyl-5F-P7AICA and its metabolite seem to be quite stable in PM specimens. Hence, also central blood might be analyzed, if no peripheral blood is available.
Collapse
Affiliation(s)
- Nadja Walle
- Institute of Legal Medicine, Saarland University, Building 49.1, Homburg 66421, Germany
| | - Adrian A Doerr
- Institute of Legal Medicine, Saarland University, Building 49.1, Homburg 66421, Germany
| | - Benjamin Peters
- Institute of Legal Medicine, Saarland University, Building 49.1, Homburg 66421, Germany
| | - Matthias W Laschke
- Institute for Clinical & Experimental Surgery, Saarland University, Building 65/66, Homburg 66421, Germany
| | - Michael D Menger
- Institute for Clinical & Experimental Surgery, Saarland University, Building 65/66, Homburg 66421, Germany
| | - Peter H Schmidt
- Institute of Legal Medicine, Saarland University, Building 49.1, Homburg 66421, Germany
| | - Markus R Meyer
- Department of Experimental and Clinical Toxicology, Center for Molecular Signaling (PZMS), Saarland University, Building 46, Homburg 66421, Germany
| | - Nadine Schaefer
- Institute of Legal Medicine, Saarland University, Building 49.1, Homburg 66421, Germany.
| |
Collapse
|
2
|
Franzin M, Di Lenardo R, Ruoso R, Dossetto P, D'Errico S, Addobbati R. Simultaneous multi-targeted forensic toxicological screening in biological matrices by MRM-IDA-EPI mode. Arch Toxicol 2024; 98:3231-3240. [PMID: 38918214 PMCID: PMC11402837 DOI: 10.1007/s00204-024-03806-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Accepted: 06/12/2024] [Indexed: 06/27/2024]
Abstract
The toxicologist ascertains drug assumptions in case of paediatric intoxications and death for overdose. The analytical approach consists of initially screening and consequently confirming drug positivity. We developed a toxicological screening method and validated its use comparing the results with a LC-MS/MS analysis. The method identifies 751 drugs and metabolites (704 in positive and 47 in negative mode). Chromatographic separation was achieved eluting mobile phase A (10 mM ammonium formate) and B (0.05% formic acid in methanol) in gradient on Kinetex Phenyl-Hexyl (50 × 4.6 mm, 2.6 μm) with 0.7 mL/min flow rate for 11 min. Multiple Reaction Monitoring (MRM) was adopted as survey scan and, after an Information-Dependent Analysis (IDA) (threshold of 30,000 for positive and 1000 cps for negative mode), the Enhanced Product Ion (scan range: 50-700 amu) was triggered. The MS/MS spectrum generated was compared with one of the libraries for identification. Data processing was optimised through creation of rules. Sample preparation, mainly consisting of deproteinization and enzymatic hydrolysis, was set up for different matrices (blood, urine, vitreous humor, synovial fluid, cadaveric tissues and larvae). Cut-off for most analytes resulted in the lowest concentration tested. When the results from the screening and LC-MS/MS analysis were compared, an optimal percentage of agreement (100%) was assessed for all matrices. Method applicability was evaluated on real paediatric intoxications and forensic cases. In conclusion, we proposed a multi-targeted, fast, sensitive and specific MRM-IDA-EPI screening having an extensive use in different toxicological fields.
Collapse
Affiliation(s)
- Martina Franzin
- Institute for Maternal and Child Health, IRCCS "Burlo Garofolo", Trieste, Italy.
| | - Rebecca Di Lenardo
- Institute for Maternal and Child Health, IRCCS "Burlo Garofolo", Trieste, Italy
| | - Rachele Ruoso
- Institute for Maternal and Child Health, IRCCS "Burlo Garofolo", Trieste, Italy
| | | | - Stefano D'Errico
- Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy
- Azienda Sanitaria Universitaria Giuliano Isontina, Trieste, Italy
| | - Riccardo Addobbati
- Institute for Maternal and Child Health, IRCCS "Burlo Garofolo", Trieste, Italy
| |
Collapse
|
3
|
Nadarajan D, O'Brien J, Cresswell S, Kele B, Mueller J, Bade R. Application of design of experiment for quantification of 71 new psychoactive substances in influent wastewater. Anal Chim Acta 2024; 1321:343036. [PMID: 39155095 DOI: 10.1016/j.aca.2024.343036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 07/25/2024] [Accepted: 07/28/2024] [Indexed: 08/20/2024]
Abstract
BACKGROUND New psychoactive substances (NPS) are of public health concern due to their sporadic proliferation and the dearth of information on toxicity when consumed. In addition to seized data from forensic and toxicology reporting, wastewater analysis serves as a complimentary tool for NPS surveillance. A method to detect 71 NPS by simple filtration followed by liquid-chromatography tandem mass spectrometry was developed to detect multiclass NPS consisting of arylcyclohexylamines, designer benzodiazepines, synthetic cannabinoids, synthetic opioids, phenethylamines, synthetic cathinones, tryptamines, and indole alkaloids. RESULTS In this work, the influential factors for electrospray ionisation were identified and optimised using the fractional factorial design and face-centred central composite design, respectively. The filtration loss during sample clean-up was assessed for all compounds. The final method was validated and applied to wastewater collected from a music festival held in Queensland in 2022. The validated method had linearity between 0.5 ng L-1 and 5000 ng L-1, the limit of quantification (LOQ) ranges from 0.6 ng L-1 to 70 ng L-1, precision within ±20 %, accuracy ranges from 70 % to 120 %, and matrix effect ranges from soft (0 %-20 %) to medium (20 %-50 %) for the majority of the compounds. NPS detected in the festival were 2-fluorodeschloroketamine, 7-hydroxymitragynine, mitragynine, N,N-dimethylpentylone, pentylone, phenibut, and O-desmethyltramadol. SIGNIFICANCE Systematic electrospray ionisation optimisation using the design of experiment for a large method is practical and provides in-depth chemical information on studied compounds. The optimised method demonstrated the applicability of analysing samples collected from a festival in this work.
Collapse
Affiliation(s)
- Dhayaalini Nadarajan
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, Woollsiana, Queensland, Australia
| | - Jake O'Brien
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, Woollsiana, Queensland, Australia; Van't Hoff Institute for Molecular Sciences (HIMS), University of Amsterdam, Netherlands
| | - Sarah Cresswell
- School of Environment and Science, Griffith University, Queensland, Australia
| | - Ben Kele
- Arris Pty Ltd, 44 Wenworth Terrace, Rockhampton, QLD, 4700, Australia
| | - Jochen Mueller
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, Woollsiana, Queensland, Australia
| | - Richard Bade
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, Woollsiana, Queensland, Australia.
| |
Collapse
|
4
|
Nytka M, Wan J, Tureček F, Lemr K. Cyclic Ion Mobility of Isomeric New Psychoactive Substances Employing Characteristic Arrival Time Distribution Profiles and Adduct Separation. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:1733-1742. [PMID: 38949154 PMCID: PMC11311522 DOI: 10.1021/jasms.4c00127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 05/14/2024] [Accepted: 06/17/2024] [Indexed: 07/02/2024]
Abstract
Analysis of new psychoactive substances (NPS), which is essential for toxicological and forensic reasons, can be made complicated by the presence of isomers. Ion mobility has been used as a standalone technique or coupled to mass spectrometry to detect and identify NPS. However, isomer separation has so far chiefly relied on chromatography. Here we report on the determination of isomeric ratios using cyclic ion mobility-mass spectrometry without any chromatographic separation. Isomers were distinguished by mobility separation of lithium adducts. Alternatively, we used arrival time distribution (ATD) profiles that were characteristic of individual isomers and were acquired for protonated molecules or fragment ions. Both approaches provided comparable results. Calculations were used to determine the structures and collision cross sections of both protonated and lithiated isomers that accurately characterized their ion mobility properties. The applicability of ATD profiles to isomer differentiation was demonstrated using direct infusion and flow injection analysis with electrospray of solutions, as well as desorption electrospray of solid samples. Data processing was performed by applying multiple linear regression to the ATD profiles. Using the proposed ATD profile-based approach, the relationships between the determined and given content of isomers showed good linearity with coefficients of determination typically greater than 0.99. Flow injection analysis using an autosampler allowed us to rapidly determine isomeric ratios in a sample containing two isomeric pairs with a minor isomer of 10% (determined 9.3% of 3-MMC and 11.0% of 3-FMC in a mixture with buphedrone and 4-FMC). The proposed approach is not only useful for NPS, but also may be applicable to small isomeric molecules analyzed by ion mobility when complete separation of isomers is not achieved.
Collapse
Affiliation(s)
- Marianna Nytka
- Department
of Analytical Chemistry, Faculty of Science, Palacký University, 17. Listopadu 12, 77146 Olomouc, Czech
Republic
| | - Jiahao Wan
- Department
of Chemistry, University of Washington, Seattle, Washington 98195-1700, United
States
| | - František Tureček
- Department
of Chemistry, University of Washington, Seattle, Washington 98195-1700, United
States
| | - Karel Lemr
- Department
of Analytical Chemistry, Faculty of Science, Palacký University, 17. Listopadu 12, 77146 Olomouc, Czech
Republic
| |
Collapse
|
5
|
Griffeuille P, El Balkhi S, Dulaurent S, Saint-Marcoux F. Probe Electrospray Ionization Tandem Mass Spectrometry for the Detection and Quantification of Benzodiazepines. Ther Drug Monit 2024; 46:522-529. [PMID: 38498915 DOI: 10.1097/ftd.0000000000001189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 10/26/2023] [Indexed: 03/20/2024]
Abstract
BACKGROUND Legally prescribed benzodiazepines (BZDs) and designer BZDs are widely misused and must be determined in multiple contexts (eg, overdose, drug-facilitated sexual assaults, or driving under the influence of drugs). This study aimed to develop a method for measuring serum BZD levels using probe electrospray ionization (PESI) mass spectrometry and an isotope dilution approach. METHODS A tandem mass spectrometer equipped with a probe electrospray ionization source in multiple reaction monitoring mode was used. Isotope dilution was applied for quantification using a deuterated internal standard at a fixed concentration for alprazolam, bromazepam, diazepam, nordiazepam, oxazepam, temazepam, zolpidem, and zopiclone. This method included designer BZDs: clonazolam, deschloroetizolam, diclazepam, etizolam, flualprazolam, flubromazepam, flubromazolam, meclonazepam, nifoxipam, and pyrazolam. Sample preparation was done by mixing 10 µL of serum with 500 µL of an ethanol/ammonium formate 0.01 mol/L buffer. Complete validation was performed, and the method was compared with liquid chromatography coupled with mass spectrometry (LC-MS/MS) and immunoassays (IC) by analyzing 40 real samples. RESULTS The analysis time for identification and quantification of the 18 molecules was 2.5 minutes. This method was fully validated, and the limits of quantification varied from 5 to 50 mcg/L depending on the molecule. In the 40 real samples, 100% of molecules (n = 89) were detected by both LC-MS/MS and PESI-MS/MS, and regression analysis showed excellent agreement between the 2 methods (r 2 = 0.98). On IC, bromazepam and zolpidem were not detected in 2 and 1 cases, respectively. CONCLUSIONS PESI-MS/MS allows serum BZD detection and measurement. Given the isotope dilution approach, a calibration curve was not required, and its performance was similar to that of LC-MS/MS, and its specificity was higher than that of IC.
Collapse
Affiliation(s)
- Pauline Griffeuille
- Department of Pharmacology and Toxicology, Limoges University Hospital, Limoges ,France ; and
| | - Souleiman El Balkhi
- Department of Pharmacology and Toxicology, Limoges University Hospital, Limoges ,France ; and
| | - Sylvain Dulaurent
- Department of Pharmacology and Toxicology, Limoges University Hospital, Limoges ,France ; and
| | - Franck Saint-Marcoux
- Department of Pharmacology and Toxicology, Limoges University Hospital, Limoges ,France ; and
- Department of Toxicology, Faculty of Pharmacy, University of Limoges, Limoges, France
| |
Collapse
|
6
|
Júnior EF, Bitencourt VS, Souza ÁBMD, Caldas ED. Target analysis of psychoactive drugs in oral fluid by QuEChERS extraction and LC-MS/MS. J Pharm Biomed Anal 2024; 244:116139. [PMID: 38608509 DOI: 10.1016/j.jpba.2024.116139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 04/03/2024] [Accepted: 04/06/2024] [Indexed: 04/14/2024]
Abstract
This study aimed to validate a modified QuEChERS method, followed by liquid chromatography-tandem mass spectrometry, for the determination of 51 psychoactive substances and screening of 22 ones in oral fluid from electronic dance music party (EDM) attendees. Unstimulated oral fluid was collected in a polypropylene tube and stored in a glass vial at -20 ºC. The sample was extracted with acetonitrile:water and MgSO4/NaOAc, followed by cleanup with primary secondary amine and MgSO4. The effectiveness of the sample storage conditions was shown to be comparable to when the Quantisal™ buffer was used, with no substantial concentration loss (< 15%) for all the substances after up to 72 hours at -20º C. The method was satisfactorily validated, with limits of detection (LOD) and quantification (LOQ) ranging from 0.04 to 0.5 ng/mL and 0.1-1.5 ng/mL, respectively, and was applied to the analysis of 62 real samples. The main substances detected were 3,4-methylenedioxymethamphetamine (MDMA) (<0.5-829 ng/mL) and/or methylenedioxyamphetamine (MDA) (10.1 - 460.6 ng/mL), found in 27 samples, and cocaine (13.0-407.3 ng/mL) and its metabolites (benzoylecgonine 0.17-214.1 ng/mL; ecgonine methyl ester 1.8-150.1 ng/mL) in eight samples. Methamphetamine (11-439 ng/mL) was detected in eight samples, along with MDMA and MDA; eutylone was detected in two cases (4.7 and 24.1 ng/mL) reported as "ecstasy" ingestion. A comparison between self-reported drug use and results of oral fluid analysis indicated that the use of illicit substances is often underreported among EDM attendees, who are often unaware of the substances they consume.
Collapse
Affiliation(s)
- Ettore Ferrari Júnior
- Forensic Analysis Laboratory, Criminalistics Institute, The Civil Police of the Federal District, Brasília, Federal District, Brazil
| | | | | | - Eloisa Dutra Caldas
- Laboratory of Toxicology, Department of Pharmacy, University of Brasília, Brasília, Federal District, Brazil.
| |
Collapse
|
7
|
Salomone A, Vincenti M. Detecting novel psychoactive substances around the world. Curr Opin Psychiatry 2024; 37:258-263. [PMID: 38818825 DOI: 10.1097/yco.0000000000000939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
PURPOSE OF REVIEW The worldwide spread of novel psychoactive substances (NPS) in the illicit drug market and their continuous increase in number and type, for the purpose of bypassing controlled substance legislation, represents a continuing challenge for forensic scientists, clinicians and enforcement authorities. We aim to provide information regarding the most urgent harms related to NPS consumption in different world regions and the current state of the art for NPS analysis. RECENT FINDINGS Unfortunately, the identification of NPS in biological samples is controversial, especially when samples are limited, or the drug is promptly and extensively metabolized. This causes a lack of information on their real diffusion in different parts of the world and in different populations. New technologies and instrumental detection of NPS in alternative samples are offering comprehensive information about NPS use. SUMMARY The lack of detection and underreporting of NPS in biological samples makes it difficult to obtain complete qualitative and quantitative information about NPS prevalence. The most innovative strategies that have been proposed in the last 2 years to assist NPS analysis and possibly facilitate the understanding of the NPS diffusion around the world are presented.
Collapse
Affiliation(s)
- Alberto Salomone
- Department of Chemistry, University of Turin
- Centro Regionale Antidoping, Orbassano, Turin, Italy
| | - Marco Vincenti
- Department of Chemistry, University of Turin
- Centro Regionale Antidoping, Orbassano, Turin, Italy
| |
Collapse
|
8
|
Marchei E, Graziano S, Varì MR, Minutillo A, Aquilina V, Pichini S, Rotolo MC. NPS-EQA PART I: Four years' experience in external quality assessment program in Italy for classical and new psychoactive substances analysis in oral fluid. J Pharm Biomed Anal 2024; 243:116084. [PMID: 38452420 DOI: 10.1016/j.jpba.2024.116084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 02/27/2024] [Accepted: 03/01/2024] [Indexed: 03/09/2024]
Abstract
In 2019, Italian National Institute of Health established an external quality assessment program (EQA) to evaluate the performance of oral fluid testing for classical and new psychoactive substances by laboratories participating in the National Early Warning System collaborative centres. This report presents the results of four rounds between 2019 and 2023. Eleven oral fluid specimens, including 3 blank samples, were prepared by adding different classes of and new psychoactive drugs at known concentrations to pre-screened drug-free oral fluid. False-negative and false-positive results were calculated for the qualitative data evaluation. The quantitative evaluation measured the imprecision and accuracy of the results, in terms of coefficient of variation (CV%) and percent error (ERR%), respectively, with respect to a mean value obtained by reference laboratories. Z-score values were then calculated. Over the years, there has been a significant improvement in false-negative results (from 42.7% in the first year to 19.4% in the last year), but not in false-positive results (from 33.3% in the first year to 22.2% in the last one). In addition to the classic drugs of abuse (e.g. cocaine, amphetamine, methadone), the substances found in false positive samples belonged to the class of synthetic cannabinoids (e.g 5-fluoro CUMYL-PINACA and 5-fluoro-EDMB-PICA), synthetic opioids (e.g butyrylfentanyl) and tryptamines (e.g. 5-methoxy-N-methyl-N-isopropyltryptamine). The four rounds yielded a mean ERR% of approximately 22.1% and a mean CV% of around 41.5%. The participating laboratories demonstrated variable performances in relation to the class of analysed psychoactive substances, as evidenced by the calculated Z-scores. Between 25% and 60% of the reported results in all rounds should be considered satisfactory. EQA is a crucial element of laboratory quality management systems. It promotes continuous improvement and maintains high standards in the field of forensic and clinical drug testing.
Collapse
Affiliation(s)
- Emilia Marchei
- National Centre on Addiction and Doping, Istituto Superiore di Sanità, Rome, Italy
| | - Silvia Graziano
- National Centre on Addiction and Doping, Istituto Superiore di Sanità, Rome, Italy
| | - Maria Rosaria Varì
- National Centre on Addiction and Doping, Istituto Superiore di Sanità, Rome, Italy
| | - Adele Minutillo
- National Centre on Addiction and Doping, Istituto Superiore di Sanità, Rome, Italy
| | - Valeria Aquilina
- Investigation, Crime and International Security, Università degli Studi Internazionali di Roma - UNINT, Rome, Italy
| | - Simona Pichini
- National Centre on Addiction and Doping, Istituto Superiore di Sanità, Rome, Italy.
| | | |
Collapse
|
9
|
Neukamm MA, Pollak S, Thoma V, Vogt S, Huppertz LM, Auwärter V. A fatal case of aspiration due to consumption of the hallucinogenic tryptamine derivative dipropyltryptamine (DPT). J Pharm Biomed Anal 2024; 240:115959. [PMID: 38183731 DOI: 10.1016/j.jpba.2023.115959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 12/27/2023] [Accepted: 12/29/2023] [Indexed: 01/08/2024]
Abstract
BACKGROUND AND AIM This case involves a 20-year-old man with prior hallucinogen-use experience, who sniffed an unknown amount of dipropyltryptamine in an apartment. Dipropyltryptamine, a hallucinogenic compound belonging to the tryptamine class is recognized for inducing effects similar to dimethyltryptamine (DMT) but with a longer duration. Ten to fifteen minutes later he experienced visual hallucinations, followed by increasing apathy. Two hours post consumption he developed abdominal pain, leading to collapse, seizure, and vomiting. Despite emergency medical resuscitation on site, transport to hospital 2.5 hours post consumption and extracorporeal life support he died 21 hours later. Relevant toxicological and morphological findings are presented. METHODS A serum sample was collected four hours post consumption. Autopsy was performed six days after death. Antemortem serum, as well as postmortem cardiac blood and urine were analyzed for alcohol and psychoactive drugs by systematic toxicological analyses employing gas chromatography-mass spectrometry (Maurer/Pfleger/Weber library among others), liquid chromatography-ion trap mass spectrometry (LC-MSn, Toxtyper™), and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Dipropyltryptamine was quantified by LC-MS/MS after solid-phase extraction. RESULTS Autopsy revealed a state after deep aspiration of gastric contents with consecutive brain edema due to oxygen deprivation. Dipropyltryptamine concentrations were approximately 210 ng/ml, 110 ng/ml and 180 ng/ml in antemortem serum, postmortem cardiac blood and urine, respectively. To the best of our knowledge, these are the first reported concentrations of dipropyltryptamine in a fatal case. CONCLUSION Unlike typical tryptamine overdose reports, this case did not present with agitation, hyperthermia, or tachycardia. Despite the individual's prior experience with tryptamines and the generally low toxicity associated with this class of hallucinogens, death in this case was an indirect consequence of the nasal consumption of a high dose of dipropyltryptamine.
Collapse
Affiliation(s)
- Merja A Neukamm
- Institute of Forensic Medicine, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Albertstraße 9, Freiburg 79104, Germany.
| | - Stefan Pollak
- Institute of Forensic Medicine, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Albertstraße 9, Freiburg 79104, Germany
| | - Vanessa Thoma
- Institute of Forensic Medicine, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Albertstraße 9, Freiburg 79104, Germany
| | - Susanne Vogt
- Institute of Forensic Medicine, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Albertstraße 9, Freiburg 79104, Germany
| | - Laura M Huppertz
- Institute of Forensic Medicine, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Albertstraße 9, Freiburg 79104, Germany
| | - Volker Auwärter
- Institute of Forensic Medicine, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Albertstraße 9, Freiburg 79104, Germany
| |
Collapse
|
10
|
Polke M, Concheiro M, Cooper G, Bogdal C, Baumgartner MR, Krämer T, Binz TM. Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method including 25 novel synthetic opioids in hair and subsequent analysis of a Swiss opioid consumer cohort. Drug Test Anal 2024. [PMID: 38382125 DOI: 10.1002/dta.3663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 01/22/2024] [Accepted: 02/01/2024] [Indexed: 02/23/2024]
Abstract
Major public health concern is raised by the evidence that common drugs like heroin are now frequently laced or replaced with highly potent novel synthetic opioids (NSOs). The objective of this study was to explore the prevalence and patterns of NSOs in a cohort of Swiss opioid users by hair analysis. Hair analysis is considered an ideal tool for retrospective consumption monitoring. Hair samples from 439 opioid users in Zurich were analyzed. Study inclusion required a previous positive hair test result for heroin metabolites, oxycodone, fentanyl, methadone, or tramadol. The samples were extracted with a two-step extraction procedure, followed by a targeted LC-MS/MS (QTRAP® 6500+) analysis in multiple reaction monitoring mode for a total of 25 NSOs. The method underwent full validation and demonstrated good selectivity and sensitivity with limits of detection (LOD) as low as 0.1 pg/mg. The analyzed sample cohort demonstrated a positivity rate for NSOs of 2.5%, including the following NSOs: butyrylfentanyl, acrylfentanyl, furanylfentanyl, methoxyacetylfentanyl, ocfentanil, U-47700, isobutyrylfentanyl and benzylfentanyl. Furthermore, we were able to identify specific consumption patterns among drug users. The results indicate that hair analysis is a valuable tool for investigating the prevalence of NSOs in drug-using populations, which seems to be low in the case of Swiss opioid users. Nevertheless, the results highlight the need for sensitive analytical detection methods in forensic toxicology to identify and monitor substance distribution in different populations.
Collapse
Affiliation(s)
- Max Polke
- Center for Forensic Hair Analytics, Zurich Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | - Marta Concheiro
- Department of Sciences, John Jay College of Criminal Justice, City University of New York, New York City, New York, USA
| | - Gail Cooper
- Department of Forensic Toxicology, Office of Chief Medical Examiner, New York City, New York, USA
| | | | - Markus R Baumgartner
- Center for Forensic Hair Analytics, Zurich Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | - Thomas Krämer
- Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | - Tina M Binz
- Center for Forensic Hair Analytics, Zurich Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
11
|
de Oliveira MC, Vides MC, Lassi DLS, Torales J, Ventriglio A, Bombana HS, Leyton V, Périco CDAM, Negrão AB, Malbergier A, Castaldelli-Maia JM. Toxicity of Synthetic Cannabinoids in K2/Spice: A Systematic Review. Brain Sci 2023; 13:990. [PMID: 37508922 PMCID: PMC10377539 DOI: 10.3390/brainsci13070990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/19/2023] [Accepted: 06/22/2023] [Indexed: 07/30/2023] Open
Abstract
(1) Background: Synthetic cannabinoids (SCs) are emerging drugs of abuse sold as 'K2', 'K9' or 'Spice'. Evidence shows that using SCs products leads to greater health risks than cannabis. They have been associated with greater toxicity and higher addiction potential unrelated to the primary psychoactive component of marijuana, Δ9-tetrahydrocannabinol (Δ9-THC). Moreover, early cases of intoxication and death related to SCs highlight the inherent danger that may accompany the use of these substances. However, there is limited knowledge of the toxicology of Spice ingredients. This systematic review intends to analyze the toxicity of SCs compounds in Spice/K2 drugs. (2) Methods: Studies analyzing synthetic cannabinoid toxicity and dependence were included in the present review. We searched the PubMed database of the US National Library of Medicine, Google Scholar, CompTox Chemicals, and Web of Science up to May 2022. (3) Results: Sixty-four articles reporting the effects of synthetic cannabinoids in humans were included in our review. Ten original papers and fifty-four case studies were also included. Fourteen studies reported death associated with synthetic cannabinoid use, with AB-CHMINACA and MDMB-CHMICA being the main reported SCs. Tachycardia and seizures were the most common toxicity symptoms. The prevalence of neuropsychiatric symptoms was higher in third-generation SCs. (4) Conclusion: SCs may exhibit higher toxicity than THC and longer-lasting effects. Their use may be harmful, especially in people with epilepsy and schizophrenia, because of the increased risk of the precipitation of psychiatric and neurologic disorders. Compared to other drugs, SCs have a higher potential to trigger a convulsive crisis, a decline in consciousness, and hemodynamic changes. Therefore, it is crucial to clarify their potential harms and increase the availability of toxicology data in both clinical and research settings.
Collapse
Affiliation(s)
- Mariana Campello de Oliveira
- Interdisciplinary Group of Alcohol and Drug Studies (GREA), Institute Perdizes, Department of Psychiatry Medical School, São Paulo University, São Paulo 05403-903, SP, Brazil
| | - Mariana Capelo Vides
- Interdisciplinary Group of Alcohol and Drug Studies (GREA), Institute Perdizes, Department of Psychiatry Medical School, São Paulo University, São Paulo 05403-903, SP, Brazil
| | - Dângela Layne Silva Lassi
- Interdisciplinary Group of Alcohol and Drug Studies (GREA), Institute Perdizes, Department of Psychiatry Medical School, São Paulo University, São Paulo 05403-903, SP, Brazil
| | - Julio Torales
- Department of Psychological Medicine, School of Medical Sciences, National University of Asuncion, San Lorenzo 111421, Paraguay
| | - Antonio Ventriglio
- Department of Experimental Medicine, Medical School, University of Foggia, 71122 Foggia, Italy
| | - Henrique Silva Bombana
- Department of Legal Medicine, Medical School, São Paulo University, São Paulo 05508-090, SP, Brazil
| | - Vilma Leyton
- Department of Legal Medicine, Medical School, São Paulo University, São Paulo 05508-090, SP, Brazil
| | | | - André Brooking Negrão
- Interdisciplinary Group of Alcohol and Drug Studies (GREA), Institute Perdizes, Department of Psychiatry Medical School, São Paulo University, São Paulo 05403-903, SP, Brazil
| | - André Malbergier
- Interdisciplinary Group of Alcohol and Drug Studies (GREA), Institute Perdizes, Department of Psychiatry Medical School, São Paulo University, São Paulo 05403-903, SP, Brazil
| | - João Maurício Castaldelli-Maia
- Interdisciplinary Group of Alcohol and Drug Studies (GREA), Institute Perdizes, Department of Psychiatry Medical School, São Paulo University, São Paulo 05403-903, SP, Brazil
- Department of Neuroscience, Medical School, FMABC University Center, Santo André 09060-870, SP, Brazil
- Department of Epidemiology, Mailman School of Public Health, Columbia University, New York, NY 10032, USA
| |
Collapse
|