1
|
Omaliko PC, Ferket PR, Ogundare TE, Apalowo OO, Enenya IG, Iwuozo OC, Han J, Fasina YO. Impact of dietary fat types on expression levels of dopamine and serotonin transporters in the ileum of broiler chickens. Poult Sci 2024; 103:104114. [PMID: 39214056 PMCID: PMC11402036 DOI: 10.1016/j.psj.2024.104114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 07/11/2024] [Accepted: 07/14/2024] [Indexed: 09/04/2024] Open
Abstract
Various types of dietary fats undergo distinct fermentation processes by gut microbes, potentially leading to the production of neurotransmitters that can influence the gut. Serotonin and dopamine are recognized neurotransmitters with positive effects on gut function. A broiler chicken trial was conducted to evaluate the influence of dietary fat types on protein expression of 2 neurotransmitter transporters, dopamine (DAT) and serotonin (5-HTT). A total of 560 day-old (Ross 708) male broiler chicks were randomly assigned to 7 dietary treatments. The experimental treatments included a basal diet of corn-soybean meal (SBM), supplemented with 3% of various fats: poultry fat (CON), olive oil (OLIV), fish oil (FISH), canola oil (CANO), lard (LARD), coconut oil (COCO), or flaxseed oil (FLAX). Bodyweight (BW) and feed conversion ratio (FCR) were recorded. Ileal tissues were aseptically collected to determine the expression levels of DAT and 5-HTT through western blot analysis. In addition, plasma samples were analyzed for reactive oxygen metabolites (d-ROM) tests on d 55. Results showed that dietary fat type inclusion did not have any detrimental effect on growth performance parameters. The expression levels of DAT were higher (P < 0.05) in FLAX treatments compared to CON treatments on d 20 and d 55, respectively. Similarly, with 5-HTT levels, FLAX, CANO, and LARD treatments were higher (P < 0.05) than CON treatments on d 20 and d 55. However, higher levels of oxidative stress (d-ROM values) were recorded in COCO (32.75 Carr U), CANO (29 Carr U), and CON treatments (25.5 Carr U) compared to FLAX (18.5 Carr U; P < 0.05) treatment. These findings suggest that incorporating dietary flaxseed oil at a 3% level in the diet has significant potential to elevate the expression levels of intestinal DAT and 5-HTT without inducing oxidative stress.
Collapse
Affiliation(s)
- Paul C Omaliko
- Department of Animal Sciences, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA
| | - Peter R Ferket
- Prestage Department of Poultry Science, North Carolina State University, Raleigh, NC 27695, USA
| | - Tunde E Ogundare
- Department of Animal Sciences, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA
| | - Oluwabunmi O Apalowo
- Department of Animal Sciences, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA
| | - Ikenna G Enenya
- Department of Animal Sciences, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA
| | - Odinaka C Iwuozo
- Department of Animal Sciences, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA
| | - Jian Han
- Department of Biology, North Carolina Agricultural and Technical State University, Greensboro, NC, 27411, USA
| | - Yewande O Fasina
- Department of Animal Sciences, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA.
| |
Collapse
|
2
|
Biswas S, Chowdhury T, Banerjee S, Dutta K, Das AK, Das D. Improving the Efficiency of Luminescent Zn(II)-Modified N-Doped GOQD Nanomaterials in Parkinson's Disease Treatment: A Theoretical Mechanistic Framework Exploring Doping Effect. Chem Asian J 2024; 19:e202400629. [PMID: 39041342 DOI: 10.1002/asia.202400629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Revised: 07/10/2024] [Accepted: 07/22/2024] [Indexed: 07/24/2024]
Abstract
Levodopa, a widely prescribed drug in Parkinson's disease treatment, stands as the foremost prodrug of dopamine. An affordable self-testing kit is utilized to monitor levodopa content in anti-parkinson drugs in human serum. A photoluminescent trinuclear Zn(II) complex [Zn3(L)2(κ1-OAc)2(κ2-OAc)2] has been synthesized, which cleaves into mononuclear ZC in aqueous solution. ZC was found to detect L-Dopa in Tris-HCl buffer, exhibiting a moderate decrease in PL-emission. The real-life utility of the ZC probe is limited, for its lower sensitivity (LOD 35.3 μM) and separation challenges. Therefore, an interface between homogeneous and heterogeneous supports has been explored, leading to the strategic development of NGOZC, where ZC was grafted onto NGOQD (Graphene oxide quantum dots). This material enables naked- eye detection under both ambient and UV light with color change from bright cyan to green, followed by dark. The nitrogen doping effect was investigated by several comparative investigations involving the synthesis of ZC-grafted GOQD, leading to enhanced quenching performance. Steady-state and time-resolved fluorescence titration study, morphological analysis, and computational calculations have been performed to get insights into the sensing mechanism. To the best of our knowledge, this as-synthesized NGOZC (LOD 1.78 nM) represents a promising strategy and platform for applications in biosensors, especially for Parkinson's and Alzheimer's diseases.
Collapse
Affiliation(s)
- Sneha Biswas
- Department of Chemistry, University College of Science, University of Calcutta, 92A. P. C. Road, Kolkata, 700009, India
| | - Tania Chowdhury
- School of Materials Sciences, Indian Association for the Cultivation of Science, 2 A & 2B, Raja S. C. Mullick Road, Jadavpur, Kolkata, 700032, India
| | - Soumadip Banerjee
- School of Mathematical & Computational Sciences, Indian Association for the Cultivation of Science, 2 A & 2B, Raja S. C. Mullick Road, Jadavpur, Kolkata, 700032, India
| | - Koushik Dutta
- Department of Polymer Science & Technology, University of Calcutta, 92, A.P.C. Road, Kolkata, West Bengal, 700009, India
| | - Abhijit K Das
- School of Mathematical & Computational Sciences, Indian Association for the Cultivation of Science, 2 A & 2B, Raja S. C. Mullick Road, Jadavpur, Kolkata, 700032, India
| | - Debasis Das
- Department of Chemistry, University College of Science, University of Calcutta, 92A. P. C. Road, Kolkata, 700009, India
| |
Collapse
|
3
|
Salomón-Flores MK, Viviano-Posadas AO, Valdes-García J, López-Guerrero V, Martínez-Otero D, Barroso-Flores J, German-Acacio JM, Bazany-Rodríguez IJ, Dorazco-González A. Optical sensing of L-dihydroxy-phenylalanine in water by a high-affinity molecular receptor involving cooperative binding of a metal coordination bond and boronate-diol. Dalton Trans 2024; 53:16541-16556. [PMID: 39327887 DOI: 10.1039/d4dt02108h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/28/2024]
Abstract
Selective recognition and sensing of catecholamine-based neurotransmitters by fluorescent synthetic receptors capable of operating in pure water is a central topic of modern supramolecular chemistry that impacts biological and analytical chemistry. Despite advances achieved in the recognition of some neurotransmitters such as dopamine, little effort has been invested in the optical recognition of other neurotransmitters of paramount importance in biochemistry and medicinal chemistry such as the drug L-dihydroxy-phenylalanine (levodopa). Herein, a cationic Cu(II)-terpyridine complex bearing an intramolecular fluorescent quinolinium ring covalently linked to phenylboronic acid (CuL1) was synthesized, structurally described by single-crystal X-ray diffraction and studied in-depth as a fluorescent receptor for neurotransmitters in water. The complex CuL1 was designed to act as a receptor for levodopa through two Lewis acids of different natures (Cu(II) and B atoms) as cooperative binding points. The receptor CuL1 was found to have a strongly acidified -B(OH)2 group (pKa = 6.2) and exceptionally high affinity for levodopa (K = 4.8 × 106 M-1) with selectivity over other related neurotransmitters such as dopamine, epinephrine, norepinephrine and nucleosides in the micromolar concentration range at physiological pH. Such levodopa affinity/selectivity for a boronic acid-based receptor in water is still rare. On the basis of spectroscopic tools (11B NMR, UV-vis, EPR, and fluorescence), high-resolution ESI-MS, crystal structure, and DFT calculations, the interaction mode of CuL1 with levodopa is proposed in a 1 : 1 model using two-point recognition involving a boronate-catechol esterification and a coordination bond Cu(II)-carboxylate. Furthermore, a visual sensing ensemble was constructed using CuL1 and the commercial fluorescent dye eosin Y. Levodopa is efficiently detected by the displacement of the eosin Y bound to the Cu(II)-receptor, monitoring its green emission. The use of Cu(II)-boronate complexes for fast and selective neurotransmitter sensing was unexplored until now.
Collapse
Affiliation(s)
- María K Salomón-Flores
- Institute of Chemistry, National Autonomous University of Mexico, Ciudad Universitaria, México, 04510, CDMX, Mexico.
| | - Alejandro O Viviano-Posadas
- Institute of Chemistry, National Autonomous University of Mexico, Ciudad Universitaria, México, 04510, CDMX, Mexico.
| | - Josue Valdes-García
- Institute of Chemistry, National Autonomous University of Mexico, Ciudad Universitaria, México, 04510, CDMX, Mexico.
| | - Víctor López-Guerrero
- Institute of Chemistry, National Autonomous University of Mexico, Ciudad Universitaria, México, 04510, CDMX, Mexico.
| | - Diego Martínez-Otero
- Institute of Chemistry, National Autonomous University of Mexico, Ciudad Universitaria, México, 04510, CDMX, Mexico.
- Centro Conjunto de Investigación en Química Sustentable, UAEM-UNAM, Instituto de Química, Universidad Nacional Autónoma de México, Carretera Toluca-Atlacomulco Km 14.5, C. P. 50200, Toluca, Estado de México, Mexico
| | - Joaquín Barroso-Flores
- Institute of Chemistry, National Autonomous University of Mexico, Ciudad Universitaria, México, 04510, CDMX, Mexico.
- Centro Conjunto de Investigación en Química Sustentable, UAEM-UNAM, Instituto de Química, Universidad Nacional Autónoma de México, Carretera Toluca-Atlacomulco Km 14.5, C. P. 50200, Toluca, Estado de México, Mexico
| | - Juan M German-Acacio
- Red de Apoyo a la Investigación, Coordinación de la Investigación Científica-UNAM, Instituto Nacional de Ciencias Médicas y Nutrición SZ, Ciudad de México, CP 14000, Mexico
| | - Iván J Bazany-Rodríguez
- Facultad de Química, Universidad Nacional Autónoma de México, Ciudad Universitaria CDMX, 04510 México, Mexico
| | - Alejandro Dorazco-González
- Institute of Chemistry, National Autonomous University of Mexico, Ciudad Universitaria, México, 04510, CDMX, Mexico.
| |
Collapse
|
4
|
Meng L, Akhoundian M, Al Azawi A, Shoja Y, Chi PY, Meinander K, Suihkonen S, Franssila S. Ultrasensitive Monolithic Dopamine Microsensors Employing Vertically Aligned Carbon Nanofibers. Adv Healthc Mater 2024; 13:e2303872. [PMID: 38837670 DOI: 10.1002/adhm.202303872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 03/19/2024] [Indexed: 06/07/2024]
Abstract
Brain-on-Chip devices, which facilitate on-chip cultures of neurons to simulate brain functions, are receiving tremendous attention from both fundamental and clinical research. Consequently, microsensors are being developed to accomplish real-time monitoring of neurotransmitters, which are the benchmarks for neuron network operation. Among these, electrochemical sensors have emerged as promising candidates for detecting a critical neurotransmitter, dopamine. However, current state-of-the-art electrochemical dopamine sensors are suffering from issues like limited sensitivity and cumbersome fabrication. Here, a novel route in monolithically microfabricating vertically aligned carbon nanofiber electrochemical dopamine microsensors is reported with an anti-blistering slow cooling process. Thanks to the microfabrication process, microsensors is created with complete insulation and large surface areas. The champion device shows extremely high sensitivity of 4.52× 104 µAµM-1·cm-2, which is two-orders-of-magnitude higher than current devices, and a highly competitive limit of detection of 0.243 nM. These remarkable figures-of-merit will open new windows for applications such as electrochemical recording from a single neuron.
Collapse
Affiliation(s)
- Lingju Meng
- Department of Chemistry and Materials Science, Aalto University, Espoo, 02150, Finland
- Micronova Nanofabrication Centre, Aalto University, Espoo, 02150, Finland
| | - Maedeh Akhoundian
- Department of Electrical Engineering and Automation, Aalto University, Espoo, 02150, Finland
| | - Anas Al Azawi
- Department of Chemistry and Materials Science, Aalto University, Espoo, 02150, Finland
- Micronova Nanofabrication Centre, Aalto University, Espoo, 02150, Finland
| | - Yalda Shoja
- Department of Chemistry and Materials Science, Aalto University, Espoo, 02150, Finland
- Micronova Nanofabrication Centre, Aalto University, Espoo, 02150, Finland
| | - Pei-Yin Chi
- Department of Chemistry and Materials Science, Aalto University, Espoo, 02150, Finland
- Micronova Nanofabrication Centre, Aalto University, Espoo, 02150, Finland
| | - Kristoffer Meinander
- Department of Bioproducts and Biosystems, Aalto University, Espoo, 02150, Finland
| | - Sami Suihkonen
- Department of Electronics and Nanoengineering, Aalto University, Espoo, 02150, Finland
| | - Sami Franssila
- Department of Chemistry and Materials Science, Aalto University, Espoo, 02150, Finland
- Micronova Nanofabrication Centre, Aalto University, Espoo, 02150, Finland
| |
Collapse
|
5
|
Kim H, Won Y, Song HW, Kwon Y, Jun M, Oh JH. Organic Mixed Ionic-Electronic Conductors for Bioelectronic Sensors: Materials and Operation Mechanisms. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2306191. [PMID: 38148583 PMCID: PMC11251567 DOI: 10.1002/advs.202306191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 12/18/2023] [Indexed: 12/28/2023]
Abstract
The field of organic mixed ionic-electronic conductors (OMIECs) has gained significant attention due to their ability to transport both electrons and ions, making them promising candidates for various applications. Initially focused on inorganic materials, the exploration of mixed conduction has expanded to organic materials, especially polymers, owing to their advantages such as solution processability, flexibility, and property tunability. OMIECs, particularly in the form of polymers, possess both electronic and ionic transport functionalities. This review provides an overview of OMIECs in various aspects covering mechanisms of charge transport including electronic transport, ionic transport, and ionic-electronic coupling, as well as conducting/semiconducting conjugated polymers and their applications in organic bioelectronics, including (multi)sensors, neuromorphic devices, and electrochromic devices. OMIECs show promise in organic bioelectronics due to their compatibility with biological systems and the ability to modulate electronic conduction and ionic transport, resembling the principles of biological systems. Organic electrochemical transistors (OECTs) based on OMIECs offer significant potential for bioelectronic applications, responding to external stimuli through modulation of ionic transport. An in-depth review of recent research achievements in organic bioelectronic applications using OMIECs, categorized based on physical and chemical stimuli as well as neuromorphic devices and circuit applications, is presented.
Collapse
Affiliation(s)
- Hyunwook Kim
- School of Chemical and Biological EngineeringInstitute of Chemical ProcessesSeoul National University1 Gwanak‐roGwanak‐guSeoul08826Republic of Korea
| | - Yousang Won
- School of Chemical and Biological EngineeringInstitute of Chemical ProcessesSeoul National University1 Gwanak‐roGwanak‐guSeoul08826Republic of Korea
| | - Hyun Woo Song
- School of Chemical and Biological EngineeringInstitute of Chemical ProcessesSeoul National University1 Gwanak‐roGwanak‐guSeoul08826Republic of Korea
| | - Yejin Kwon
- School of Chemical and Biological EngineeringInstitute of Chemical ProcessesSeoul National University1 Gwanak‐roGwanak‐guSeoul08826Republic of Korea
| | - Minsang Jun
- School of Chemical and Biological EngineeringInstitute of Chemical ProcessesSeoul National University1 Gwanak‐roGwanak‐guSeoul08826Republic of Korea
| | - Joon Hak Oh
- School of Chemical and Biological EngineeringInstitute of Chemical ProcessesSeoul National University1 Gwanak‐roGwanak‐guSeoul08826Republic of Korea
| |
Collapse
|
6
|
Rybachuk O, Nesterenko Y, Zhovannyk V. Modern advances in spinal cord regeneration: hydrogel combined with neural stem cells. Front Pharmacol 2024; 15:1419797. [PMID: 38994202 PMCID: PMC11236698 DOI: 10.3389/fphar.2024.1419797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Accepted: 06/11/2024] [Indexed: 07/13/2024] Open
Abstract
Severe spinal cord injuries (SCI) lead to loss of functional activity of the body below the injury site, affect a person's ability to self-care and have a direct impact on performance. Due to the structural features and functional role of the spinal cord in the body, the consequences of SCI cannot be completely overcome at the expense of endogenous regenerative potential and, developing over time, lead to severe complications years after injury. Thus, the primary task of this type of injury treatment is to create artificial conditions for the regenerative growth of damaged nerve fibers through the area of the SCI. Solving this problem is possible using tissue neuroengineering involving the technology of replacing the natural tissue environment with synthetic matrices (for example, hydrogels) in combination with stem cells, in particular, neural/progenitor stem cells (NSPCs). This approach can provide maximum stimulation and support for the regenerative growth of axons of damaged neurons and their myelination. In this review, we consider the currently available options for improving the condition after SCI (use of NSC transplantation or/and replacement of the damaged area of the SCI with a matrix, specifically a hydrogel). We emphasise the expediency and effectiveness of the hydrogel matrix + NSCs complex system used for the reconstruction of spinal cord tissue after injury. Since such a complex approach (a combination of tissue engineering and cell therapy), in our opinion, allows not only to creation of conditions for supporting endogenous regeneration or mechanical reconstruction of the spinal cord, but also to strengthen endogenous regeneration, prevent the spread of the inflammatory process, and promote the restoration of lost reflex, motor and sensory functions of the injured area of spinal cord.
Collapse
Affiliation(s)
- Oksana Rybachuk
- Bogomoletz Institute of Physiology NAS of Ukraine, Kyiv, Ukraine
- Institute of Genetic and Regenerative Medicine, M. D. Strazhesko National Scientific Center of Cardiology, Clinical and Regenerative Medicine, National Academy of Medical Sciences of Ukraine, Kyiv, Ukraine
| | | | | |
Collapse
|
7
|
Wang K, Ren S, Jia Y, Yan X. An Ultrasensitive Biomimetic Optic Afferent Nervous System with Circadian Learnability. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2309489. [PMID: 38468430 DOI: 10.1002/advs.202309489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/04/2024] [Indexed: 03/13/2024]
Abstract
The optic afferent nervous system (OANS) plays a significant role in generating vision and circadian behaviors based on light detection and signals from the endocrine system. However, the bionic simulation of this photochemically mediated behavior is still a challenge for neuromorphic devices. Herein, stimuli of neurotransmitters at ultralow concentrations and illumination are coupled to artificial synapses with the aid of biofunctionalized heterojunction and tunneling to successfully simulate a circadian neural response. Furthermore, the mechanisms underlying the photosensitive synaptic current in response to stimuli are described. Interestingly, this OANS is demonstrated to be capable of mimicking normal and abnormal circadian learnability by combining the measured synaptic current with a three-layer spike neural network. Strong theoretical and experimental evidence, as well as applications, are provided for the proposed biomimetic OANS to demonstrate that it can reproduce biological circadian behavior, thus establishing it as a promising candidate for future neuromorphic intelligent robots.
Collapse
Affiliation(s)
- Kaiyang Wang
- College of Electronic Information and Optical Engineering, Nankai University, Tianjin, 300071, P. R. China
| | - Shuhui Ren
- College of Electronic Information and Optical Engineering, Nankai University, Tianjin, 300071, P. R. China
| | - Yunfang Jia
- College of Electronic Information and Optical Engineering, Nankai University, Tianjin, 300071, P. R. China
| | - Xiaobing Yan
- Key Laboratory of Brain-Like Neuromorphic Devices and Systems of Hebei Province, College of Electron and Information Engineering, Hebei University, Baoding, 071002, P. R. China
| |
Collapse
|
8
|
Ahmadian-Alam L, Andrade A, Song E. Electrochemical detection of glutamate and histamine using redox-labeled stimuli-responsive polymer as a synthetic target receptor. ACS APPLIED POLYMER MATERIALS 2024; 6:5630-5641. [PMID: 39444408 PMCID: PMC11498899 DOI: 10.1021/acsapm.4c00121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2024]
Abstract
Glutamate (Glu) and histamine (His) are two major neurotransmitters that play many critical roles in brain physiological functions and neurological disorders. Therefore, specific and sensitive monitoring of Glu and His is essential in the diagnosis and treatment of various mental health and neurodegenerative disorders. Both being non-electroactive species, direct electrochemical detection of Glu and His has been challenging. Herein, we report a stimuli-responsive polymer-based biosensor for the electrochemical detection of Glu and His. The polymer-based target receptors consist of a linear chain stimuli-responsive templated polymer hybrid that is labeled with an osmium-based redox-active reporter molecules to elicit conformation-dependent electrochemical responses. The polymers are then attached to a gold electrode to implement an electrochemical sensor. The cyclic voltammetry (CV) and square-wave voltammetry (SWV) results confirmed the polymers' conformational changes due to the specific target (i.e., Glu and His) recognition and the corresponding electrochemical detection capabilities. The voltammetry results indicate that this biosensor can be used as a 'signal-on' and 'signal-off' sensors for the detection of Glu and His concentrations, respectively. The developed biosensor also showed excellent regeneration capability by fully recovering the initial current signal after rinsing with deionized water. To further validate the polymer's utility as a target bioreceptor, the surface plasmon resonance (SPR) technique was used to characterize the binding affinity between the designed polymers and the target chemical. The SPR results exhibited the equilibrium dissociation constants (KD) of 2.40 μM and 1.54 μM for the polymer-Glu and polymer-His interactions, respectively. The results obtained this work strongly suggest that the proposed sensing technology could potentially be used as a platform for monitoring non-electroactive neurochemicals from animal models.
Collapse
Affiliation(s)
- Leila Ahmadian-Alam
- Department of Electrical & Computer Engineering, University of New Hampshire, Durham, NH 03824, United States
| | - Arturo Andrade
- Department of Neuroscience, Brown University, Providence, RI 02912, United States
- Robert J. & Nancy D. Carney Institute for Brain Science, Brown University, Providence, RI 02912, United States
| | - Edward Song
- Department of Electrical & Computer Engineering, University of New Hampshire, Durham, NH 03824, United States
| |
Collapse
|
9
|
Kim Y, Lee Y, Yoo J, Nam KS, Jeon W, Lee S, Park S. Multifunctional and Flexible Neural Probe with Thermally Drawn Fibers for Bidirectional Synaptic Probing in the Brain. ACS NANO 2024; 18:13277-13285. [PMID: 38728175 PMCID: PMC11112973 DOI: 10.1021/acsnano.4c02578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 04/23/2024] [Accepted: 05/01/2024] [Indexed: 05/12/2024]
Abstract
Synapses in the brain utilize two distinct communication mechanisms: chemical and electrical. For a comprehensive investigation of neural circuitry, neural interfaces should be capable of both monitoring and stimulating these types of physiological interactions. However, previously developed interfaces for neurotransmitter monitoring have been limited in interaction modality due to constraints in device size, fabrication techniques, and the usage of flexible materials. To address this obstacle, we propose a multifunctional and flexible fiber probe fabricated through the microwire codrawing thermal drawing process, which enables the high-density integration of functional components with various materials such as polymers, metals, and carbon fibers. The fiber enables real-time monitoring of transient dopamine release in vivo, real-time stimulation of cell-specific neuronal populations via optogenetic stimulation, single-unit electrophysiology of individual neurons localized to the tip of the neural probe, and chemical stimulation via drug delivery. This fiber will improve the accessibility and functionality of bidirectional interrogation of neurochemical mechanisms in implantable neural probes.
Collapse
Affiliation(s)
- Yeji Kim
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-road, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Yunheum Lee
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-road, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Jeongeun Yoo
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-road, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Kum Seok Nam
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-road, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Woojin Jeon
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-road, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Seungmin Lee
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-road, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Seongjun Park
- Department
of Bio and Brain Engineering, Korea Advanced
Institute of Science and Technology (KAIST), 291 Daehak-road, Yuseong-gu, Daejeon 34141, Republic of Korea
- Department
of Materials Science, Korea Advanced Institute
of Science and Technology (KAIST), 291 Daehak-road, Yuseong-gu, Daejeon 34141, Republic
of Korea
- KAIST
Institute for NanoCentury (KINC), 291 Daehak-road, Yuseong-gu, Daejeon 34141, Republic
of Korea
| |
Collapse
|
10
|
Pathak NK, Sahoo P, Tripathy U. Nonlinear study of indolamines: A hidden property that might have possible implications in neurodegeneration. Talanta 2024; 272:125808. [PMID: 38373364 DOI: 10.1016/j.talanta.2024.125808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 02/13/2024] [Accepted: 02/14/2024] [Indexed: 02/21/2024]
Abstract
Indolamines (e.g., serotonin and melatonin) are tryptophan-derived class of neurotransmitters and neuromodulators that play crucial roles in mood regulation, sleep-wake cycles, and gastrointestinal functions. These biogenic amines exert their effects by binding to specific receptors in the central nervous system, influencing neuronal activity and signalling cascades. Indolamines are vital in maintaining homeostasis, and imbalances in their levels have been implicated in various neurological and psychiatric disorders. Hence, in the present study, we have investigated the nonlinear properties of indolamines under a continuous wave (CW) and pulsed laser excitation using the closed-aperture (CA) Z-scan technique. The CA Z-scan is a cost-effective and sensitive analytical tool for investigating nonlinear properties. It is observed that indolamines show negative refractive and positive absorptive nonlinearity under in vitro physiological conditions. The origin of nonlinearity is ascribed to the thermo-optical effect governed by the saturated atomic absorption and molecular orientation mechanisms under CW and pulsed laser excitation, respectively. The strength of nonlinearity is found to vary linearly with the concentration of indolamines. Overall, serotonin possesses stronger nonlinearity than melatonin. The maximum nonlinearity (refractive index (n2) & absorption coefficient (β)) for melatonin under CW and pulsed laser excitations are (-1.266 × 10-12 m2W-1 and -1.883 × 10-17 m2W-1) & (8.046 × 10-8 mW-1 and 1.516 × 10-13 mW-1), respectively. Meanwhile, the maximum n2 and β under pulsed laser excitation for serotonin are obtained as -3.195 × 10-17 m2W-1 and 6.149 × 10-12 mW-1, respectively. The outcome of the results may be utilized in understanding processes mediated by indolamines and designing therapeutic interventions.
Collapse
Affiliation(s)
- Nitesh Kumar Pathak
- Department of Physics, Indian Institute of Technology (Indian School of Mines) Dhanbad, 826004, Jharkhand, India
| | - Priyadarshi Sahoo
- Department of Physics, Indian Institute of Technology (Indian School of Mines) Dhanbad, 826004, Jharkhand, India
| | - Umakanta Tripathy
- Department of Physics, Indian Institute of Technology (Indian School of Mines) Dhanbad, 826004, Jharkhand, India.
| |
Collapse
|
11
|
M R K, Panicker LR, Narayan R, Kotagiri YG. Biopolymer-protected graphene-Fe 3O 4 nanocomposite based wearable microneedle sensor: toward real-time continuous monitoring of dopamine. RSC Adv 2024; 14:7131-7141. [PMID: 38414985 PMCID: PMC10898425 DOI: 10.1039/d4ra00110a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 02/20/2024] [Indexed: 02/29/2024] Open
Abstract
Neurological disorders can occur in the human body as a result of nano-level variations in the neurotransmitter levels. Patients affected by neuropsychiatric disorders, that are chronic require continuous monitoring of these neurotransmitter levels for effective disease management. The current work focus on developing a highly sensitive and personalized sensor for continuous monitoring of dopamine. Here we propose a wearable microneedle-based electrochemical sensor, to continuously monitor dopamine in interstitial fluid (ISF). A chitosan-protected hybrid nanomaterial Fe3O4-GO composite has been used as a chemical recognition element protected by Nafion antifouling coating layer. The morphological and physiochemical characterizations of the nanocomposite were carried out with XRD, XPS, FESEM, EDAX and FT-IR. The principle of the developed sensor relies on orthogonal detection of dopamine with square wave voltammetry and chronoamperometric techniques. The microneedle sensor array exhibited an attractive analytical performance toward detecting dopamine in phosphate buffer and artificial ISF. The limit of detection (LOD) of the developed sensor was observed to be low, 90 nM in square wave voltammetry and 0.6 μM in chronoamperometric analysis. The practical applicability of the microneedle sensor array has been demonstrated on a skin-mimicking phantom gel model. The microneedle sensor also exhibited good long-term storage stability, reproducibility, and sensitivity. All of these promising results suggest that the proposed microneedle sensor array could be reliable for the continuous monitoring of dopamine.
Collapse
Affiliation(s)
- Keerthanaa M R
- Department of Chemistry, Indian Institute of Technology Palakkad Palakkad Kerala 678 557 India
| | - Lakshmi R Panicker
- Department of Chemistry, Indian Institute of Technology Palakkad Palakkad Kerala 678 557 India
| | - Roger Narayan
- Department of Biomedical Engineering, NC State University Raleigh NC 27695 USA
| | - Yugender Goud Kotagiri
- Department of Chemistry, Indian Institute of Technology Palakkad Palakkad Kerala 678 557 India
| |
Collapse
|
12
|
Lachance GP, Gauvreau D, Boisselier É, Boukadoum M, Miled A. Breaking Barriers: Exploring Neurotransmitters through In Vivo vs. In Vitro Rivalry. SENSORS (BASEL, SWITZERLAND) 2024; 24:647. [PMID: 38276338 PMCID: PMC11154401 DOI: 10.3390/s24020647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 01/11/2024] [Accepted: 01/16/2024] [Indexed: 01/27/2024]
Abstract
Neurotransmitter analysis plays a pivotal role in diagnosing and managing neurodegenerative diseases, often characterized by disturbances in neurotransmitter systems. However, prevailing methods for quantifying neurotransmitters involve invasive procedures or require bulky imaging equipment, therefore restricting accessibility and posing potential risks to patients. The innovation of compact, in vivo instruments for neurotransmission analysis holds the potential to reshape disease management. This innovation can facilitate non-invasive and uninterrupted monitoring of neurotransmitter levels and their activity. Recent strides in microfabrication have led to the emergence of diminutive instruments that also find applicability in in vitro investigations. By harnessing the synergistic potential of microfluidics, micro-optics, and microelectronics, this nascent realm of research holds substantial promise. This review offers an overarching view of the current neurotransmitter sensing techniques, the advances towards in vitro microsensors tailored for monitoring neurotransmission, and the state-of-the-art fabrication techniques that can be used to fabricate those microsensors.
Collapse
Affiliation(s)
| | - Dominic Gauvreau
- Department Electrical Engineering, Université Laval, Québec, QC G1V 0A6, Canada; (G.P.L.); (D.G.)
| | - Élodie Boisselier
- Department Ophthalmology and Otolaryngology—Head and Neck Surgery, Université Laval, Québec, QC G1V 0A6, Canada;
| | - Mounir Boukadoum
- Department Computer Science, Université du Québec à Montréal, Montréal, QC H2L 2C4, Canada;
| | - Amine Miled
- Department Electrical Engineering, Université Laval, Québec, QC G1V 0A6, Canada; (G.P.L.); (D.G.)
| |
Collapse
|
13
|
Iftikhar T, Iftikhar N, Chi G, Qiu W, Xie Y, Liang Z, Huang C, Su L. Unlocking the future of brain research: MOFs, TMOs, and MOFs/TMOs for electrochemical NTMs detection and analysis. Talanta 2024; 267:125146. [PMID: 37688896 DOI: 10.1016/j.talanta.2023.125146] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 08/29/2023] [Accepted: 08/31/2023] [Indexed: 09/11/2023]
Abstract
The central nervous system relies heavily on neurotransmitters (NTMs), and NTM imbalances have been linked to a wide range of neurological conditions. Thus, the development of reliable detection techniques is essential for advancing brain studies. This review offers a comprehensive analysis of metal-organic frameworks (MOFs), transition metal oxides (TMOs), and MOFs-derived TMOs (MOFs/TMOs) as materials for electrochemical (EC) sensors targeting the detection of key NTMs, specifically dopamine (DA), epinephrine (EP), and serotonin (SR). The unique properties and diverse families of MOFs and TMOs, along with their nanostructured hybrids, are discussed in the context of EC sensing. The review also addresses the challenges in detecting NTMs and proposes a systematic approach to tackle these obstacles. Despite the vast amount of research on MOFs and TMOs-based EC sensors for DA detection, the review highlights the gaps in the literature for MOFs/TMOs-based EC sensors specifically for EP and SR detection, as well as the limited research on microneedles (MNs)-based EC sensors modified with MOFs, TMOs, and MOFs/TMOs for NTMs detection. This review serves as a foundation to encourage researchers to further explore the potential applications of MOFs, TMOs, and MOFs/TMOs-based EC sensors in the context of neurological disorders and other health conditions related to NTMs imbalances.
Collapse
Affiliation(s)
- Tayyaba Iftikhar
- School of Biomedical Engineering, International Health Science Innovation Center, Shenzhen Key Laboratory of Nano-Biosensing Technology, Marshall Laboratory of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, 518055, PR China
| | - Nishwa Iftikhar
- Department of Medicine, Quaid-e-Azam Medical College, Bahawalpur, Punjab, Pakistan
| | - Guilin Chi
- School of Biomedical Engineering, International Health Science Innovation Center, Shenzhen Key Laboratory of Nano-Biosensing Technology, Marshall Laboratory of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, 518055, PR China
| | - Wenjing Qiu
- Department of Rheumatology, South China Hospital, Medical School, Shenzhen University, Shenzhen, 518116, PR China
| | - Yuanting Xie
- School of Biomedical Engineering, International Health Science Innovation Center, Shenzhen Key Laboratory of Nano-Biosensing Technology, Marshall Laboratory of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, 518055, PR China.
| | - Zhen Liang
- School of Biomedical Engineering, International Health Science Innovation Center, Shenzhen Key Laboratory of Nano-Biosensing Technology, Marshall Laboratory of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, 518055, PR China
| | - Cibo Huang
- Department of Rheumatology, South China Hospital, Medical School, Shenzhen University, Shenzhen, 518116, PR China
| | - Lei Su
- School of Biomedical Engineering, International Health Science Innovation Center, Shenzhen Key Laboratory of Nano-Biosensing Technology, Marshall Laboratory of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, 518055, PR China.
| |
Collapse
|
14
|
Singh S, Ahuja A, Pathak S. Potential Role of Oxidative Stress in the Pathophysiology of Neurodegenerative Disorders. Comb Chem High Throughput Screen 2024; 27:2043-2061. [PMID: 38243956 DOI: 10.2174/0113862073280680240101065732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 11/27/2023] [Accepted: 12/14/2023] [Indexed: 01/22/2024]
Abstract
Neurodegeneration causes premature death in the peripheral and central nervous system. Neurodegeneration leads to the accumulation of oxidative stress, inflammatory responses, and the generation of free radicals responsible for nervous disorders like amyotrophic lateral sclerosis, Alzheimer's disease, Parkinson's disease, and Huntington's disorders. Therefore, focus must be diverted towards treating and managing these disorders, as it is very challenging. Furthermore, effective therapies are also lacking, so the growing interest of the global market must be inclined towards developing newer therapeutic approaches that can intercept the progression of neurodegeneration. Emerging evidences of research findings suggest that antioxidant therapy has significant potential in modulating disease phenotypes. This makes them promising candidates for further investigation. This review focuses on the role of oxidative stress and reactive oxygen species in the pathological mechanisms of various neurodegenerative diseases, amyotrophic lateral sclerosis, Alzheimer's disease, Parkinson's disease, and Huntington's disorders and their neuroprotection. Additionally, it highlights the potential of antioxidant-based therapeutics in mitigating disease severity in humans and improving patient compliance. Ongoing extensive global research further sheds light on exploring new therapeutic targets for a deeper understanding of disease mechanisms in the field of medicine and biology targeting neurogenerative disorders.
Collapse
Affiliation(s)
- Sonia Singh
- Institute of Pharmaceutical Research, GLA University Mathura, U.P, 281406, India
| | - Ashima Ahuja
- Institute of Pharmaceutical Research, GLA University Mathura, U.P, 281406, India
| | - Shilpi Pathak
- Institute of Pharmaceutical Research, GLA University Mathura, U.P, 281406, India
| |
Collapse
|
15
|
Niihori M, Földes T, Readman CA, Arul R, Grys DB, Nijs BD, Rosta E, Baumberg JJ. SERS Sensing of Dopamine with Fe(III)-Sensitized Nanogaps in Recleanable AuNP Monolayer Films. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2302531. [PMID: 37605460 DOI: 10.1002/smll.202302531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 07/06/2023] [Indexed: 08/23/2023]
Abstract
Sensing of neurotransmitters (NTs) down to nm concentrations is demonstrated by utilizing self-assembled monolayers of plasmonic 60 nm Au nanoparticles in close-packed arrays immobilized onto glass substrates. Multiplicative surface-enhanced Raman spectroscopy enhancements are achieved by integrating Fe(III) sensitizers into the precisely-defined <1 nm nanogaps, to target dopamine (DA) sensing. The transparent glass substrates allow for efficient access from both sides of the monolayer aggregate films by fluid and light, allowing repeated sensing in different analytes. Repeated reusability after analyte sensing is shown through oxygen plasma cleaning protocols, which restore pristine conditions for the nanogaps. Examining binding competition in multiplexed sensing of two catecholamine NTs, DA and epinephrine, reveals their bidentate binding and their interactions. These systems are promising for widespread microfluidic integration enabling a wide range of continuous biofluid monitoring for applications in precision health.
Collapse
Affiliation(s)
- Marika Niihori
- Nanophotonics Centre, Department of Physics, Cavendish Laboratory, University of Cambridge, Cambridge, England, CB3 0HE, UK
| | - Tamás Földes
- Department of Physics and Astronomy, University College London, London, WC1E 6BT, UK
| | - Charlie A Readman
- Nanophotonics Centre, Department of Physics, Cavendish Laboratory, University of Cambridge, Cambridge, England, CB3 0HE, UK
| | - Rakesh Arul
- Nanophotonics Centre, Department of Physics, Cavendish Laboratory, University of Cambridge, Cambridge, England, CB3 0HE, UK
| | - David-Benjamin Grys
- Nanophotonics Centre, Department of Physics, Cavendish Laboratory, University of Cambridge, Cambridge, England, CB3 0HE, UK
| | - Bart de Nijs
- Nanophotonics Centre, Department of Physics, Cavendish Laboratory, University of Cambridge, Cambridge, England, CB3 0HE, UK
| | - Edina Rosta
- Department of Physics and Astronomy, University College London, London, WC1E 6BT, UK
| | - Jeremy J Baumberg
- Nanophotonics Centre, Department of Physics, Cavendish Laboratory, University of Cambridge, Cambridge, England, CB3 0HE, UK
| |
Collapse
|
16
|
Świt P, Pollap A, Orzeł J. Spectroscopic Determination of Acetylcholine (ACh): A Representative Review. Top Curr Chem (Cham) 2023; 381:16. [PMID: 37169979 PMCID: PMC10175388 DOI: 10.1007/s41061-023-00426-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 04/22/2023] [Indexed: 05/13/2023]
Abstract
Acetylcholine (ACh) is one of the most crucial neurotransmitters of the cholinergic system found in vertebrates and invertebrates and is responsible for many processes in living organisms. Disturbances in ACh transmission are closely related to dementia in Alzheimer's and Parkinson's disease. ACh in biological samples is most often determined using chromatographic techniques, radioenzymatic assays, enzyme-linked immunosorbent assay (ELISA), or potentiometric methods. An alternative way to detect and determine acetylcholine is applying spectroscopic techniques, due to low limits of detection and quantification, which is not possible with the methods mentioned above. In this review article, we described a detailed overview of different spectroscopic methods used to determine ACh with a collection of validation parameters as a perspective tool for routine analysis, especially in basic research on animal models on central nervous system. In addition, there is a discussion of examples of other biological materials from clinical and preclinical studies to give the whole spectrum of spectroscopic methods application. Descriptions of the developed chemical sensors, as well as the use of flow technology, were also presented. It is worth emphasizing the inclusion in the article of multi-component analysis referring to other neurotransmitters, as well as the description of the tested biological samples and extraction procedures. The motivation to use spectroscopic techniques to conduct this type of analysis and future perspectives in this field are briefly discussed.
Collapse
Affiliation(s)
- Paweł Świt
- Institute of Chemistry, Faculty of Science and Technology, University of Silesia in Katowice, 9 Szkolna Street, 40-006, Katowice, Poland.
| | | | - Joanna Orzeł
- Institute of Chemistry, Faculty of Science and Technology, University of Silesia in Katowice, 9 Szkolna Street, 40-006, Katowice, Poland
| |
Collapse
|
17
|
Chen WH, Wang W, Lin Q, Grys DB, Niihori M, Huang J, Hu S, de Nijs B, Scherman OA, Baumberg JJ. Plasmonic Sensing Assay for Long-Term Monitoring (PSALM) of Neurotransmitters in Urine. ACS NANOSCIENCE AU 2023; 3:161-171. [PMID: 37096231 PMCID: PMC10119978 DOI: 10.1021/acsnanoscienceau.2c00048] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 11/25/2022] [Accepted: 11/28/2022] [Indexed: 04/26/2023]
Abstract
A liquid-based surface-enhanced Raman spectroscopy assay termed PSALM is developed for the selective sensing of neurotransmitters (NTs) with a limit of detection below the physiological range of NT concentrations in urine. This assay is formed by quick and simple nanoparticle (NP) "mix-and-measure" protocols, in which FeIII bridges NTs and gold NPs inside the sensing hotspots. Detection limits of NTs from PreNP PSALM are significantly lower than those of PostNP PSALM, when urine is pretreated by affinity separation. Optimized PSALM enables the long-term monitoring of NT variation in urine in conventional settings for the first time, allowing the development of NTs as predictive or correlative biomarkers for clinical diagnosis.
Collapse
Affiliation(s)
- Wei-Hsin Chen
- NanoPhotonics
Centre, Cavendish Laboratory, University
of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE, U.K.
| | - Wenting Wang
- NanoPhotonics
Centre, Cavendish Laboratory, University
of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE, U.K.
- Melville
Laboratory for Polymer Synthesis, Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW, U.K.
| | - Qianqi Lin
- NanoPhotonics
Centre, Cavendish Laboratory, University
of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE, U.K.
| | - David-Benjamin Grys
- NanoPhotonics
Centre, Cavendish Laboratory, University
of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE, U.K.
| | - Marika Niihori
- NanoPhotonics
Centre, Cavendish Laboratory, University
of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE, U.K.
| | - Junyang Huang
- NanoPhotonics
Centre, Cavendish Laboratory, University
of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE, U.K.
| | - Shu Hu
- NanoPhotonics
Centre, Cavendish Laboratory, University
of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE, U.K.
| | - Bart de Nijs
- NanoPhotonics
Centre, Cavendish Laboratory, University
of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE, U.K.
| | - Oren A. Scherman
- Melville
Laboratory for Polymer Synthesis, Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW, U.K.
| | - Jeremy J. Baumberg
- NanoPhotonics
Centre, Cavendish Laboratory, University
of Cambridge, J J Thomson Avenue, Cambridge CB3 0HE, U.K.
- JJB,
| |
Collapse
|
18
|
Al-Sayyar A, Hammad MM, Williams MR, Al-Onaizi M, Abubaker J, Alzaid F. Neurotransmitters in Type 2 Diabetes and the Control of Systemic and Central Energy Balance. Metabolites 2023; 13:384. [PMID: 36984824 PMCID: PMC10058084 DOI: 10.3390/metabo13030384] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 02/10/2023] [Accepted: 02/13/2023] [Indexed: 03/08/2023] Open
Abstract
Efficient signal transduction is important in maintaining the function of the nervous system across tissues. An intact neurotransmission process can regulate energy balance through proper communication between neurons and peripheral organs. This ensures that the right neural circuits are activated in the brain to modulate cellular energy homeostasis and systemic metabolic function. Alterations in neurotransmitters secretion can lead to imbalances in appetite, glucose metabolism, sleep, and thermogenesis. Dysregulation in dietary intake is also associated with disruption in neurotransmission and can trigger the onset of type 2 diabetes (T2D) and obesity. In this review, we highlight the various roles of neurotransmitters in regulating energy balance at the systemic level and in the central nervous system. We also address the link between neurotransmission imbalance and the development of T2D as well as perspectives across the fields of neuroscience and metabolism research.
Collapse
Affiliation(s)
| | | | | | - Mohammed Al-Onaizi
- Dasman Diabetes Institute, Kuwait City 15462, Kuwait
- Department of Anatomy, Faculty of Medicine, Kuwait University, Kuwait City 13110, Kuwait
| | | | - Fawaz Alzaid
- Dasman Diabetes Institute, Kuwait City 15462, Kuwait
- Institut Necker Enfants Malades-INEM, Université Paris Cité, CNRS, INSERM, F-75015 Paris, France
| |
Collapse
|
19
|
Hu Z, Li Y, Figueroa-Miranda G, Musal S, Li H, Martínez-Roque MA, Hu Q, Feng L, Mayer D, Offenhäusser A. Aptamer based biosensor platforms for neurotransmitters analysis. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
|
20
|
Intramolecular interactions (O-H∙∙∙O, C-H∙∙∙N, N-H∙∙∙π) in isomers of neutral, cation, and anion dopamine molecules: A DFT study on the influence of solvents (water and ethanol). J Mol Model 2023; 29:67. [PMID: 36773132 DOI: 10.1007/s00894-023-05466-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Accepted: 02/01/2023] [Indexed: 02/12/2023]
Abstract
CONTEXT Dopamine (DA) is one of the most important neurotransmitters associated with numerous neural disorders. This investigation reports the intramolecular interactions present in the isomers of neutral (DA0), anionic (DA-), and cationic (DA+) dopamine isomers in gas, water, and ethanol mediums. Neutral and anion isomers have O-H∙∙∙O, C-H∙∙∙N intramolecular hydrogen bonds and N-H∙∙∙π interactions. All the interactions are electrostatic in nature. Isomers of cation dopamine show no intramolecular interactions in the solvent. Natural charges from natural bond orbital (NBO) analysis show that O-H∙∙∙O bonds and the N-H∙∙∙π interactions are the most and least polar, respectively. 1H NMR study reveals the inverse linear correlation between shielding constant and electron density in a solvent medium. HOMO-LUMO energy gap indicates higher stability for neutral and cationic forms of dopamine isomers in water and ethanol medium. METHODS We have optimized all the structural forms of dopamine molecule using the Becke three hybrid exchange and Lee-Yang-Parr correlation functional with Grimme's dispersion correction, B3LYP-D3(BJ), and aug-cc-pVTZ basis set using the Gaussian16 software. Vibrational frequency analysis with no imaginary frequencies confirms the nature of global minima. The solvent studies (water and ethanol) were carried out using the SCRF keyword and the polarisable continuum model (PCM) of Miertus and Tomasi. NBO analysis and NMR studies were also performed for all conformers. Topology analysis was explored using the software Multiwfn.
Collapse
|
21
|
Stuart T, Jeang WJ, Slivicki RA, Brown BJ, Burton A, Brings VE, Alarcón-Segovia LC, Agyare P, Ruiz S, Tyree A, Pruitt L, Madhvapathy S, Niemiec M, Zhuang J, Krishnan S, Copits BA, Rogers JA, Gereau RW, Samineni VK, Bandodkar AJ, Gutruf P. Wireless, Battery-Free Implants for Electrochemical Catecholamine Sensing and Optogenetic Stimulation. ACS NANO 2023; 17:561-574. [PMID: 36548126 DOI: 10.1021/acsnano.2c09475] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Neurotransmitters and neuromodulators mediate communication between neurons and other cell types; knowledge of release dynamics is critical to understanding their physiological role in normal and pathological brain function. Investigation into transient neurotransmitter dynamics has largely been hindered due to electrical and material requirements for electrochemical stimulation and recording. Current systems require complex electronics for biasing and amplification and rely on materials that offer limited sensor selectivity and sensitivity. These restrictions result in bulky, tethered, or battery-powered systems impacting behavior and that require constant care of subjects. To overcome these challenges, we demonstrate a fully implantable, wireless, and battery-free platform that enables optogenetic stimulation and electrochemical recording of catecholamine dynamics in real time. The device is nearly 1/10th the size of previously reported examples and includes a probe that relies on a multilayer electrode architecture featuring a microscale light emitting diode (μ-LED) and a carbon nanotube (CNT)-based sensor with sensitivities among the highest recorded in the literature (1264.1 nA μM-1 cm-2). High sensitivity of the probe combined with a center tapped antenna design enables the realization of miniaturized, low power circuits suitable for subdermal implantation even in small animal models such as mice. A series of in vitro and in vivo experiments highlight the sensitivity and selectivity of the platform and demonstrate its capabilities in freely moving, untethered subjects. Specifically, a demonstration of changes in dopamine concentration after optogenetic stimulation of the nucleus accumbens and real-time readout of dopamine levels after opioid and naloxone exposure in freely behaving subjects highlight the experimental paradigms enabled by the platform.
Collapse
Affiliation(s)
- Tucker Stuart
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, United States
| | - William J Jeang
- Department of Materials Science and Engineering, Northwestern University, Evanston, Illinois 60201, United States
| | - Richard A Slivicki
- Department of Anesthesiology, Washington University School of Medicine, St. Louis, Missouri 63110, United States
- Washington University Pain Center, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Bobbie J Brown
- Department of Anesthesiology, Washington University School of Medicine, St. Louis, Missouri 63110, United States
- Washington University Pain Center, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Alex Burton
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, United States
| | - Victoria E Brings
- Department of Anesthesiology, Washington University School of Medicine, St. Louis, Missouri 63110, United States
- Washington University Pain Center, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Lilian C Alarcón-Segovia
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60201, United States
| | - Prophecy Agyare
- Department of Neuroscience, Northwestern University, Evanston, Illinois 60201, United States
| | - Savanna Ruiz
- Department of Materials Science and Engineering, Northwestern University, Evanston, Illinois 60201, United States
| | - Amanda Tyree
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, United States
| | - Lindsay Pruitt
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, United States
| | - Surabhi Madhvapathy
- Department of Materials Science and Engineering, Northwestern University, Evanston, Illinois 60201, United States
| | - Martin Niemiec
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, United States
| | - James Zhuang
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, United States
| | - Siddharth Krishnan
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60201, United States
| | - Bryan A Copits
- Department of Anesthesiology, Washington University School of Medicine, St. Louis, Missouri 63110, United States
- Washington University Pain Center, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - John A Rogers
- Department of Materials Science and Engineering, Northwestern University, Evanston, Illinois 60201, United States
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60201, United States
- Department of Mechanical Engineering, Northwestern University, Evanston, Illinois 60201, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60201, United States
- Department of Neurological Surgery, Feinberg School of Medicine, Northwestern University, Evanston, Illinois 60201, United States
- Department of Neurological Surgery, Northwestern University, Evanston, Illinois 60208, United States
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, Illinois 60208, United States
| | - Robert W Gereau
- Department of Anesthesiology, Washington University School of Medicine, St. Louis, Missouri 63110, United States
- Washington University Pain Center, Washington University School of Medicine, St. Louis, Missouri 63110, United States
- Department of Neuroscience, Washington University, St. Louis, Missouri 63110, United States
- Department of Biomedical Engineering, Washington University, St. Louis, Missouri 63110, United States
| | - Vijay K Samineni
- Department of Anesthesiology, Washington University School of Medicine, St. Louis, Missouri 63110, United States
- Washington University Pain Center, Washington University School of Medicine, St. Louis, Missouri 63110, United States
| | - Amay J Bandodkar
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, North Carolina 27606, United States
- Center for Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST), North Carolina State University, Raleigh, North Carolina 27606, United States
| | - Philipp Gutruf
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, United States
- Department of Electrical and Computer Engineering, University of Arizona, Tucson, Arizona 85721, United States
- Bio5 Institute, University of Arizona, Tucson, Arizona 85721, United States
- Neuroscience GIDP, University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|
22
|
Quantum control of optoelectronic and thermodynamic properties of dopamine molecule in external electric field : A DFT and TD-DFT study. COMPUT THEOR CHEM 2023. [DOI: 10.1016/j.comptc.2023.114051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
23
|
Kaur H, Siwal SS, Saini RV, Singh N, Thakur VK. Significance of an Electrochemical Sensor and Nanocomposites: Toward the Electrocatalytic Detection of Neurotransmitters and Their Importance within the Physiological System. ACS NANOSCIENCE AU 2022; 3:1-27. [PMID: 37101467 PMCID: PMC10125382 DOI: 10.1021/acsnanoscienceau.2c00039] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/17/2022] [Accepted: 10/17/2022] [Indexed: 11/07/2022]
Abstract
A prominent neurotransmitter (NT), dopamine (DA), is a chemical messenger that transmits signals between one neuron to the next to pass on a signal to and from the central nervous system (CNS). The imbalanced concentration of DA may cause numerous neurological sicknesses and syndromes, for example, Parkinson's disease (PD) and schizophrenia. There are many types of NTs in the brain, including epinephrine, norepinephrine (NE), serotonin, and glutamate. Electrochemical sensors have offered a creative direction to biomedical analysis and testing. Researches are in progress to improve the performance of sensors and develop new protocols for sensor design. This review article focuses on the area of sensor growth to discover the applicability of polymers and metallic particles and composite materials as tools in electrochemical sensor surface incorporation. Electrochemical sensors have attracted the attention of researchers as they possess high sensitivity, quick reaction rate, good controllability, and instantaneous detection. Efficient complex materials provide considerable benefits for biological detection as they have exclusive chemical and physical properties. Due to distinctive electrocatalytic characteristics, metallic nanoparticles add fascinating traits to materials that depend on the material's morphology and size. Herein, we have collected much information on NTs and their importance within the physiological system. Furthermore, the electrochemical sensors and corresponding techniques (such as voltammetric, amperometry, impedance, and chronoamperometry) and the different types of electrodes' roles in the analysis of NTs are discussed. Furthermore, other methods for detecting NTs include optical and microdialysis methods. Finally, we show the advantages and disadvantages of different techniques and conclude remarks with future perspectives.
Collapse
Affiliation(s)
- Harjot Kaur
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Samarjeet Singh Siwal
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Reena V. Saini
- Department of Biotechnology, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Nirankar Singh
- Department of Chemistry, M.M. Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana-Ambala, Haryana 133207, India
| | - Vijay Kumar Thakur
- Biorefining and Advanced Materials Research Center, Scotland’s Rural College (SRUC), Kings Buildings, Edinburgh EH9 3JG, United Kingdom
- School of Engineering, University of Petroleum & Energy Studies (UPES), Dehradun, Uttarakhand 248007, India
- Centre for Research & Development, Chandigarh University, Mohali, Punjab 140413, India
| |
Collapse
|
24
|
Ying D, Rosenberg J, Singh NK, Hall DA. A 26.5 pA rms Neurotransmitter Front-End With Class-AB Background Subtraction. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:692-702. [PMID: 35900998 DOI: 10.1109/tbcas.2022.3194809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
This paper presents an analog front-end (AFE) for fast-scan cyclic voltammetry (FSCV) with analog background subtraction using a pseudo-differential sensing scheme to cancel the large non-faradaic current before seeing the front-end. As a result, the AFE can be compact and low-power compared to conventional FSCV AFEs with dedicated digital back-ends to digitize and subtract the background from subsequent recordings. The reported AFE, fabricated in a 0.18- μ m CMOS process, consists of a class-AB common-mode rejection circuit, a low-input-impedance current conveyor, and a 1st-order current-mode delta-sigma (ΔΣ) modulator with an infinite impulse response quantizer. This AFE achieves an effective dynamic range of 83 dB with a state-of-the-art 39.2 pArms input-referred noise when loaded with a 1 nF input capacitance (26.5 pArms open-circuit) across a 5 kHz bandwidth while consuming an average power of 3.7 μW. This design was tested with carbon-fiber microelectrodes scanned at 300 V/s using flow-injection of dopamine, a key neurotransmitter.
Collapse
|
25
|
Lachance GP, Boisselier É, Boukadoum M, Miled A. Towards an advanced neurotechnological system: colorimetric sensing with a novel grism-based spectrometer, functionalized gold nanoparticles and a heterogeneous embedded system. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2022; 380:20210016. [PMID: 35658674 DOI: 10.1098/rsta.2021.0016] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 12/16/2021] [Indexed: 06/15/2023]
Abstract
Neurotransmitter sensing in the brain is crucial for the understanding of neuro-degenerative diseases. Most modern methods for the purpose rely on bulky instruments or are disruptive to the neurotransmitter medium. In this work, we describe and evaluate the design of a novel, compact and non-invasive instrument for neurotransmitter detection based on the colorimetric sensing method. The instrument includes a grism-based spectrometer that measures the wavelength shift of gold nanoparticles that are functionalized with aptamers to act as neurotransmitter-specific markers. It also includes microfluidic and electronic subsystems for sample preparation and control, and processing of the obtained signal. The instrument is tested with gold nanoparticles and its performance is compared to that of a commercial instrument, showing that the designed prototype matches the commercial instrument in performance while being much smaller, and it can surpass it with further improvements. This article is part of the theme issue 'Advanced neurotechnologies: translating innovation for health and well-being'.
Collapse
Affiliation(s)
- Gabriel P Lachance
- Department of Electrical and Computer Engineering, Université Laval, Québec Canada
| | - Élodie Boisselier
- Department of Ophthalmology and Otolaryngology-Head and Neck Surgery, Université Laval, Québec Canada
| | - Mounir Boukadoum
- Department of Computer Science, Université du Québec À Montréal (UQÀM), Montréal, Québec, Canada
| | - Amine Miled
- Department of Electrical and Computer Engineering, Université Laval, Québec Canada
| |
Collapse
|
26
|
Siwadamrongpong R, Sato N, Sugie K, Ohta Y, Haruta M, Takehara H, Tashiro H, Sasagawa K, Ohta J. Development of Compact Readout Device for Neural Observation System using Fluorescence Imaging and Fast-scan Cyclic Voltammetry. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:4864-4867. [PMID: 36085844 DOI: 10.1109/embc48229.2022.9871016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
A readout device for a dual-functional neural observation system is presented. The authors separately developed the reading operation of an implantable CMOS image sensor and a setup for fast-scan cyclic voltammetry and implemented them together in a microcontroller-based device. The developed imaging readout device with a size of [Formula: see text] can reach the highest reading rate of 160 fps with a 120×268 pixel image sensor. The voltammetry function was verified through an experiment using commercial carbon fiber electrodes in phosphate-buffered saline. When the imaging is sequentially operated with 400 V/s-scan rate voltammetry from -0.4 to 1.3 V, the system can operate at up to 60 fps. With this system, calcium imaging and dopamine recording in a freely behaving mouse can be achieved together in a simpler manner. This study aims to be the basis for the development of an implantable multi-functional sensor.
Collapse
|
27
|
de Vries LP, van de Weijer MP, Bartels M. The human physiology of well-being: A systematic review on the association between neurotransmitters, hormones, inflammatory markers, the microbiome and well-being. Neurosci Biobehav Rev 2022; 139:104733. [PMID: 35697161 DOI: 10.1016/j.neubiorev.2022.104733] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 03/09/2022] [Accepted: 06/07/2022] [Indexed: 02/08/2023]
Abstract
To understand the pathways through which well-being contributes to health, we performed a systematic review according to the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines on the association between well-being and physiological markers in four categories, neurotransmitters, hormones, inflammatory markers, and microbiome. We identified 91 studies. Neurotransmitter studies (knumber of studies=9) reported only a possible positive association between serotonin and well-being. For the hormone studies (k = 48), a lower momentary cortisol level was related to higher well-being (meta-analytic r = -0.06), and a steeper diurnal slope of cortisol levels. Inflammatory marker studies (k = 36) reported negative or non-significant relations with well-being, with meta-analytic estimates of respectively r = -0.07 and r = -0.05 for C-reactive protein and interleukin-6. Microbiome studies (k = 4) reported inconsistent associations between different bacteria abundance and well-being. The results indicate possible but small roles of serotonin, cortisol, and inflammatory markers in explaining differences in well-being. The inconsistent and limited results for other markers and microbiome require further research. Future directions for a complete picture of the physiological factors underlying well-being are proposed.
Collapse
Affiliation(s)
- Lianne P de Vries
- Department of Biological Psychology, Vrije Universiteit Amsterdam, the Netherlands; Amsterdam Public Health Research Institute, Amsterdam University Medical Centres, Amsterdam, the Netherlands.
| | - Margot P van de Weijer
- Department of Biological Psychology, Vrije Universiteit Amsterdam, the Netherlands; Amsterdam Public Health Research Institute, Amsterdam University Medical Centres, Amsterdam, the Netherlands
| | - Meike Bartels
- Department of Biological Psychology, Vrije Universiteit Amsterdam, the Netherlands; Amsterdam Public Health Research Institute, Amsterdam University Medical Centres, Amsterdam, the Netherlands
| |
Collapse
|
28
|
Teleanu RI, Niculescu AG, Roza E, Vladâcenco O, Grumezescu AM, Teleanu DM. Neurotransmitters-Key Factors in Neurological and Neurodegenerative Disorders of the Central Nervous System. Int J Mol Sci 2022; 23:5954. [PMID: 35682631 PMCID: PMC9180936 DOI: 10.3390/ijms23115954] [Citation(s) in RCA: 79] [Impact Index Per Article: 39.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 05/22/2022] [Accepted: 05/24/2022] [Indexed: 12/14/2022] Open
Abstract
Neurotransmitters are molecules that amplify, transmit, and convert signals in cells, having an essential role in information transmission throughout the nervous system. Hundreds of such chemicals have been discovered in the last century, continuing to be identified and studied concerning their action on brain health. These substances have been observed to influence numerous functions, including emotions, thoughts, memories, learning, and movements. Thus, disturbances in neurotransmitters' homeostasis started being correlated with a plethora of neurological and neurodegenerative disorders. In this respect, the present paper aims to describe the most important neurotransmitters, broadly classified into canonical (e.g., amino acids, monoamines, acetylcholine, purines, soluble gases, neuropeptides) and noncanonical neurotransmitters (e.g., exosomes, steroids, D-aspartic acid), and explain their link with some of the most relevant neurological conditions. Moreover, a brief overview of the recently developed neurotransmitters' detection methods is offered, followed by several considerations on the modulation of these substances towards restoring homeostasis.
Collapse
Affiliation(s)
- Raluca Ioana Teleanu
- Department of Pediatric Neurology, “Dr. Victor Gomoiu” Children’s Hospital, 022102 Bucharest, Romania; (R.I.T.); (E.R.); (O.V.)
- “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania;
| | - Adelina-Gabriela Niculescu
- Department of Science and Engineering of Oxide Materials and Nanomaterials, Politehnica University of Bucharest, 011061 Bucharest, Romania;
| | - Eugenia Roza
- Department of Pediatric Neurology, “Dr. Victor Gomoiu” Children’s Hospital, 022102 Bucharest, Romania; (R.I.T.); (E.R.); (O.V.)
- “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania;
| | - Oana Vladâcenco
- Department of Pediatric Neurology, “Dr. Victor Gomoiu” Children’s Hospital, 022102 Bucharest, Romania; (R.I.T.); (E.R.); (O.V.)
- “Carol Davila” University of Medicine and Pharmacy, 020021 Bucharest, Romania;
| | - Alexandru Mihai Grumezescu
- Department of Science and Engineering of Oxide Materials and Nanomaterials, Politehnica University of Bucharest, 011061 Bucharest, Romania;
- Research Institute of the University of Bucharest—ICUB, University of Bucharest, 050657 Bucharest, Romania
- Academy of Romanian Scientists, Ilfov No. 3, 050044 Bucharest, Romania
| | | |
Collapse
|
29
|
Ackermann J, Metternich JT, Herbertz S, Kruss S. Biosensing with Fluorescent Carbon Nanotubes. Angew Chem Int Ed Engl 2022; 61:e202112372. [PMID: 34978752 PMCID: PMC9313876 DOI: 10.1002/anie.202112372] [Citation(s) in RCA: 76] [Impact Index Per Article: 38.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Revised: 12/28/2021] [Indexed: 12/23/2022]
Abstract
Biosensors are powerful tools for modern basic research and biomedical diagnostics. Their development requires substantial input from the chemical sciences. Sensors or probes with an optical readout, such as fluorescence, offer rapid, minimally invasive sensing of analytes with high spatial and temporal resolution. The near-infrared (NIR) region is beneficial because of the reduced background and scattering of biological samples (tissue transparency window) in this range. In this context, single-walled carbon nanotubes (SWCNTs) have emerged as versatile NIR fluorescent building blocks for biosensors. Here, we provide an overview of advances in SWCNT-based NIR fluorescent molecular sensors. We focus on chemical design strategies for diverse analytes and summarize insights into the photophysics and molecular recognition. Furthermore, different application areas are discussed-from chemical imaging of cellular systems and diagnostics to in vivo applications and perspectives for the future.
Collapse
Affiliation(s)
- Julia Ackermann
- Biomedical NanosensorsFraunhofer Institute for Microelectronic Circuits and SystemsFinkenstrasse 6147057DuisburgGermany
- Department EBSUniversity Duisburg-EssenBismarckstrasse 8147057DuisburgGermany
| | - Justus T. Metternich
- Physical ChemistryRuhr-University BochumUniversitätsstrasse 15044801BochumGermany
- Biomedical NanosensorsFraunhofer Institute for Microelectronic Circuits and SystemsFinkenstrasse 6147057DuisburgGermany
| | - Svenja Herbertz
- Biomedical NanosensorsFraunhofer Institute for Microelectronic Circuits and SystemsFinkenstrasse 6147057DuisburgGermany
| | - Sebastian Kruss
- Physical ChemistryRuhr-University BochumUniversitätsstrasse 15044801BochumGermany
- Biomedical NanosensorsFraunhofer Institute for Microelectronic Circuits and SystemsFinkenstrasse 6147057DuisburgGermany
| |
Collapse
|
30
|
Ackermann J, Metternich JT, Herbertz S, Kruss S. Biosensing with Fluorescent Carbon Nanotubes. Angew Chem Int Ed Engl 2022. [DOI: 10.1002/ange.202112372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Julia Ackermann
- Biomedical Nanosensors Fraunhofer Institute for Microelectronic Circuits and Systems Finkenstrasse 61 47057 Duisburg Germany
- Department EBS University Duisburg-Essen Bismarckstrasse 81 47057 Duisburg Germany
| | - Justus T. Metternich
- Physical Chemistry Ruhr-University Bochum Universitätsstrasse 150 44801 Bochum Germany
- Biomedical Nanosensors Fraunhofer Institute for Microelectronic Circuits and Systems Finkenstrasse 61 47057 Duisburg Germany
| | - Svenja Herbertz
- Biomedical Nanosensors Fraunhofer Institute for Microelectronic Circuits and Systems Finkenstrasse 61 47057 Duisburg Germany
| | - Sebastian Kruss
- Physical Chemistry Ruhr-University Bochum Universitätsstrasse 150 44801 Bochum Germany
- Biomedical Nanosensors Fraunhofer Institute for Microelectronic Circuits and Systems Finkenstrasse 61 47057 Duisburg Germany
| |
Collapse
|
31
|
Pyne A, Nandi S, Layek S, Ghosh M, Nandi PK, Bera N, Sarkar N. Influence of a Polyneurotransmitter on DNA-Mediated Förster-Based Resonance Energy Transfer: A Path Leading to White Light Generation. J Phys Chem B 2021; 125:12637-12653. [PMID: 34784202 DOI: 10.1021/acs.jpcb.1c06836] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The physiologically important biomolecule, dopamine (DA), shows strong self-oxidation and aggregation behaviors, which have been controlled and modulated to result in fluorescent polydopamine (F-PDA) nanoparticles. On the other hand, the simultaneous binding of two diverse deoxyribonucleic acid (DNA) binding probes, 4',6-diamidino-2-phenylindole dihydrochloride (DAPI) and ethidium bromide (EtBr), has been elaborately established to follow the Förster-based resonance energy transfer (FRET) pathway. The comparative understanding of this DNA-mediated FRET in three media, phosphate buffer saline (PBS) of pH 7.4, DA, and F-PDA, has concluded that the FRET efficiency in the three media follows the order: PBS > DA > F-PDA. This controlled FRET in the fluorescent F-PDA matrix serves a pivotal role for efficient white light (WL) generation with excellent Commission Internationale de l'Eclairage (CIE) parameters that match well with that of pure WL emission. The obtained WL emission has been shown to be very specific with respect to concentrations of different participating components and the excitation wavelength of the illuminating source. Furthermore, the optical properties of the WL emitting solution have been observed to be retained excellently inside the well-known agarose gel matrix. Finally, the mechanistic pathway behind such a FRET-based WL generation has been established in detail, and to the best of our knowledge, the current study offers the first and only report that discloses the influence of a fluorescent polyneurotransmitter matrix for successful generation of WL emission.
Collapse
Affiliation(s)
- Arghajit Pyne
- Department of Chemistry, Indian Institute of Technology, Kharagpur 721302, West Bengal, India
| | - Sourav Nandi
- Department of Chemistry, Indian Institute of Technology, Kharagpur 721302, West Bengal, India
| | - Souvik Layek
- Department of Chemistry, Indian Institute of Technology, Kharagpur 721302, West Bengal, India
| | - Meghna Ghosh
- Department of Chemistry, Indian Institute of Technology, Kharagpur 721302, West Bengal, India
| | - Pratyush Kiran Nandi
- Department of Chemistry, Indian Institute of Technology, Kharagpur 721302, West Bengal, India
| | - Nanigopal Bera
- Department of Chemistry, Indian Institute of Technology, Kharagpur 721302, West Bengal, India
| | - Nilmoni Sarkar
- Department of Chemistry, Indian Institute of Technology, Kharagpur 721302, West Bengal, India
| |
Collapse
|
32
|
Ojeda-Granados C, Abondio P, Setti A, Sarno S, Gnecchi-Ruscone GA, González-Orozco E, De Fanti S, Jiménez-Kaufmann A, Rangel-Villalobos H, Moreno-Estrada A, Sazzini M. Dietary, Cultural and Pathogens-Related Selective Pressures Shaped Differential Adaptive Evolution Among Native Mexican Populations. Mol Biol Evol 2021; 39:6379730. [PMID: 34597392 PMCID: PMC8763094 DOI: 10.1093/molbev/msab290] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Native American genetic ancestry has been remarkably implicated with increased risk of diverse health issues in several Mexican populations, especially in relation to the dramatic changes in environmental, dietary, and cultural settings they have recently undergone. In particular, the effects of these ecological transitions and Westernization of lifestyles have been investigated so far predominantly on Mestizo individuals. Nevertheless, indigenous groups, rather than admixed Mexicans, have plausibly retained the highest proportions of genetic components shaped by natural selection in response to the ancient milieu experienced by Mexican ancestors during their pre-Columbian evolutionary history. These formerly adaptive variants have the potential to represent the genetic determinants of some biological traits that are peculiar to Mexican people, as well as a reservoir of loci with possible biomedical relevance. To test such a hypothesis, we used genome-wide genotype data to infer the unique adaptive evolution of Native Mexican groups selected as reasonable descendants of the main pre-Columbian Mexican civilizations. A combination of haplotype-based and gene-network analyses enabled us to detect genomic signatures ascribable to polygenic adaptive traits plausibly evolved by the main genetic clusters of Mexican indigenous populations to cope with local environmental and/or cultural conditions. Some of these adaptations were found to play a role in modulating the susceptibility/resistance of these groups to certain pathological conditions, thus providing new evidence that diverse selective pressures have contributed to shape the current biological and disease-risk patterns of present-day Native and Mestizo Mexican populations.
Collapse
Affiliation(s)
- Claudia Ojeda-Granados
- Laboratory of Molecular Anthropology & Centre for Genome Biology, Department of Biological, Geological and Environmental Sciences (BiGeA), University of Bologna, Bologna, Italy.,Department of Molecular Biology in Medicine, Civil Hospital of Guadalajara "Fray Antonio Alcalde" & Health Sciences Center, University of Guadalajara, Jalisco, Mexico
| | - Paolo Abondio
- Laboratory of Molecular Anthropology & Centre for Genome Biology, Department of Biological, Geological and Environmental Sciences (BiGeA), University of Bologna, Bologna, Italy
| | - Alice Setti
- Laboratory of Molecular Anthropology & Centre for Genome Biology, Department of Biological, Geological and Environmental Sciences (BiGeA), University of Bologna, Bologna, Italy.,Laboratory of Molecular Virology, Department of Cellular, Computational and Integrative Biology (CIBIO), University of Trento, Povo-Trento, Italy
| | - Stefania Sarno
- Laboratory of Molecular Anthropology & Centre for Genome Biology, Department of Biological, Geological and Environmental Sciences (BiGeA), University of Bologna, Bologna, Italy
| | - Guido Alberto Gnecchi-Ruscone
- Laboratory of Molecular Anthropology & Centre for Genome Biology, Department of Biological, Geological and Environmental Sciences (BiGeA), University of Bologna, Bologna, Italy.,Max Planck Institute for Evolutionary Anthropology, Leipzig, Germany
| | - Eduardo González-Orozco
- National Laboratory of Genomics for Biodiversity (LANGEBIO), UGA, CINVESTAV, Irapuato, Guanajuato, Mexico
| | - Sara De Fanti
- Interdepartmental Centre Alma Mater Research Institute on Global Challenges and Climate Change, University of Bologna, Italy
| | - Andres Jiménez-Kaufmann
- National Laboratory of Genomics for Biodiversity (LANGEBIO), UGA, CINVESTAV, Irapuato, Guanajuato, Mexico
| | - Héctor Rangel-Villalobos
- Instituto de Investigación en Genética Molecular, Centro Universitario de la Ciénega, Universidad de Guadalajara, Ocotlán, Jalisco, Mexico
| | - Andrés Moreno-Estrada
- National Laboratory of Genomics for Biodiversity (LANGEBIO), UGA, CINVESTAV, Irapuato, Guanajuato, Mexico
| | - Marco Sazzini
- Laboratory of Molecular Anthropology & Centre for Genome Biology, Department of Biological, Geological and Environmental Sciences (BiGeA), University of Bologna, Bologna, Italy.,Interdepartmental Centre Alma Mater Research Institute on Global Challenges and Climate Change, University of Bologna, Italy
| |
Collapse
|
33
|
Landari H, Messaddeq Y, Miled A. Microscope-FTIR Spectrometry Based Sensor for Neurotransmitters Detection. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:938-948. [PMID: 34432634 DOI: 10.1109/tbcas.2021.3107805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In this work, we present a new sensing approach for aqueous samples based on the microscope-FTIR spectrometer and applied for neurotransmitters. Our contribution in this work consists of a new sample handling system for the microscope-FTIR spectrometer based on a total reflective mirror, a heated hydrophobic layer for solvent removal/evaporation and sample confinement and a microfluidic system that handles sample injection unlike standard sample handling system which was based only on a total reflective mirror. In addition, another part of our contribution consists of proposing a new algorithm to extract molecular composition of the solution with high estimation ratios and based on the analysis of detected peaks on IR spectra. The data acquired from the microscope-FTIR spectrometer was analyzed by a newly developed algorithm to identify each neurotransmitter in homogeneous and non-homogeneous solutions with high selectivity. We used six neurotransmitter molecules (Dopamine hydrochloride, L-Ascorbic acid, Acetylcholine chloride, y-Aminobutyric, Glycine and L-Glutamic acid). The results obtained based on the algorithm developed showed that, using the new system, the six neurotransmitters can be identified in homogeneous and mixture solutions with an estimation ratio range of 88.8%-100% for Dopamine hydrochloride, 80%-100% for L-Ascorbic acid, 75%-100% for Acetylcholine chloride, 75%-100% for L-Glutamic, 77.7%-100% for y-Aminobutyric and 75%-100% for Glycine.
Collapse
|
34
|
A rapid screening method to select microdialysis carriers for hydrophobic compounds. PLoS One 2021; 16:e0256920. [PMID: 34469501 PMCID: PMC8409685 DOI: 10.1371/journal.pone.0256920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 08/18/2021] [Indexed: 11/19/2022] Open
Abstract
Microdialysis is a minimally invasive sampling technique which is widely applied in many fields including clinical studies. This technique usually has limitation on sampling hydrophobic compounds as aqueous solutions are commonly used as the perfusates. The relative recovery of hydrophobic compounds is often low and irreproducible because of the non-specific binding to microdialysis membranes or catheter tubing. Carriers such as cyclodextrins have been used to improve the recovery and consistency, however the identification of an optimal carrier can only be achieved after time-consuming and costly microdialysis experiments. We therefore developed a rapid, convenient, and low-cost method to identify the optimal carriers for sampling hydrophobic compounds with the use of centrifugal ultrafiltration. Doxorubicin was used as the model compound and its relative recoveries obtained from centrifugal ultrafiltration and from microdialysis were compared. The results show that the relative recoveries are highly correlated (correlation coefficient ≥ 0.9) between centrifugal ultrafiltration and microdialysis when different types or different concentrations of cyclodextrins were used as the carriers. In addition to doxorubicin, this method was further confirmed on three other drugs with different hydrophobicity. This method may facilitate and broaden the use of microdialysis perfusion on sampling or delivering hydrophobic substances in various applications.
Collapse
|
35
|
Emerging Applications of Optical Fiber-Based Devices for Brain Research. ADVANCED FIBER MATERIALS 2021. [DOI: 10.1007/s42765-021-00092-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
36
|
Tripathi S, Mazumder PM. Neuroprotective Efficacy of Apple Cider Vinegar on Zinc-High Fat Diet-Induced Mono Amine Oxidase Alteration in Murine Model of AD. J Am Coll Nutr 2021; 41:658-667. [PMID: 34323669 DOI: 10.1080/07315724.2021.1948933] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVE Monoamine Oxidase (MAO), which catalyzes the oxidative deamination of amines present in the brain and peripheral tissues, is involved in the metabolism of monoamines and is vital for cognition. This study was designed to examine the protective effect of Apple Cider Vinegar (ACV) on MAO and amine neurotransmitters such as dopamine (DA), serotonin (5-HT), non-adrenaline (NA) levels. METHOD In this experiment, out of five groups, three groups of animals were pretreated with one of the test drugs each i.e., Chrysin (10 mg/kg), ACV (0.7% v/v) and Rivastigmine (2.5 mg/kg) along with Zn with high fat diet (HFD) for 3 months and the rest two groups were that of control and disease induced. After the treatment period, mice were examined for MAO-A & B, DA, 5-HT and NA level estimation. RESULTS The results showed that Zn with HFD had induced a significant increase (p < 0.01, p < 0.001) in MAO-A & B levels and a significant decrease (p < 0.001) in the levels of 5-HT, DA, and NA. Pretreatment of test drugs with Zn with HFD caused a restoration activity and a significant decrease (p < 0.01, p < 0.05) in MAO-A & B levels and a significant increase (p < 0.05, p < 0.01, p < 0.001) in the level of DA, 5HT and NA as compared to the Zn treated group. Amongst all three test drugs mentioned above, the ACV-treated group showed the most improvement during pretreatment. CONCLUSIONS The findings suggest that ACV, might prove to be a beneficial nutraceutical & provide a protective effect against Alzheimer's disease (AD)-like neurological diseases.
Collapse
Affiliation(s)
- Smriti Tripathi
- Department of Pharmaceutical Sciences & Technology, Birla Institute of Technology, Ranchi, Jharkhand, India
| | - Papiya Mitra Mazumder
- Department of Pharmaceutical Sciences & Technology, Birla Institute of Technology, Ranchi, Jharkhand, India
| |
Collapse
|
37
|
Lee WK, Kim Y, Jang H, Sim JH, Choi HJ, Shin Y, Choi JJ. Exogenous Transforming Growth Factor-β in Brain-Induced Symptoms of Central Fatigue and Suppressed Dopamine Production in Mice. Int J Mol Sci 2021; 22:ijms22052580. [PMID: 33806649 PMCID: PMC7961432 DOI: 10.3390/ijms22052580] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Revised: 02/24/2021] [Accepted: 03/02/2021] [Indexed: 02/07/2023] Open
Abstract
Myalgic encephalomyelitis (ME)/chronic fatigue syndrome (CFS) is one of the most refractory diseases in humans and is characterized by severe central fatigue accompanied with various symptoms that affect daily life, such as impaired memory, depression, and somatic pain. However, the etiology and pathophysiological mechanisms of CFS remain unknown. To investigate the pathophysiological role of transforming growth factor (TGF)-β1, we injected a cytokine into the lateral ventricle of a C57BL/6 mouse. The intracranial injection of TGF-β1 increased the immobility duration in a forced swimming test (FST) and time spent at the closed arm in elevated plus maze (EPM) analysis. The mice injected with TGF-β1 into their brain showed increased sensitivity to pain in a von Frey test, and had a decreased retention time on rotarod and latency time in a bright box in a passive avoidance test. In addition, the serum levels of muscle fatigue biomarkers, lactate dehydrogenase (LDH) and creatine kinase (CK), were significantly increased after administration of TGF-β1. Intracranial injection of TGF-β1 significantly reduced the production of tyrosine hydroxylase (TH) in the ventral tegmental area, accompanied by a decreased level of dopamine in the striatum. The suppression of TH expression by TGF-β1 was confirmed in the human neuroblastoma cell line, SH-SY5Y. These results, which show that TGF-β1 induced fatigue-like behaviors by suppressing dopamine production, suggest that TGF-β1 plays a critical role in the development of central fatigue and is, therefore, a potential therapeutic target of the disease.
Collapse
|
38
|
Purcell EK, Becker MF, Guo Y, Hara SA, Ludwig KA, McKinney CJ, Monroe EM, Rechenberg R, Rusinek CA, Saxena A, Siegenthaler JR, Sortwell CE, Thompson CH, Trevathan JK, Witt S, Li W. Next-Generation Diamond Electrodes for Neurochemical Sensing: Challenges and Opportunities. MICROMACHINES 2021; 12:128. [PMID: 33530395 PMCID: PMC7911340 DOI: 10.3390/mi12020128] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 01/19/2021] [Accepted: 01/19/2021] [Indexed: 12/12/2022]
Abstract
Carbon-based electrodes combined with fast-scan cyclic voltammetry (FSCV) enable neurochemical sensing with high spatiotemporal resolution and sensitivity. While their attractive electrochemical and conductive properties have established a long history of use in the detection of neurotransmitters both in vitro and in vivo, carbon fiber microelectrodes (CFMEs) also have limitations in their fabrication, flexibility, and chronic stability. Diamond is a form of carbon with a more rigid bonding structure (sp3-hybridized) which can become conductive when boron-doped. Boron-doped diamond (BDD) is characterized by an extremely wide potential window, low background current, and good biocompatibility. Additionally, methods for processing and patterning diamond allow for high-throughput batch fabrication and customization of electrode arrays with unique architectures. While tradeoffs in sensitivity can undermine the advantages of BDD as a neurochemical sensor, there are numerous untapped opportunities to further improve performance, including anodic pretreatment, or optimization of the FSCV waveform, instrumentation, sp2/sp3 character, doping, surface characteristics, and signal processing. Here, we review the state-of-the-art in diamond electrodes for neurochemical sensing and discuss potential opportunities for future advancements of the technology. We highlight our team's progress with the development of an all-diamond fiber ultramicroelectrode as a novel approach to advance the performance and applications of diamond-based neurochemical sensors.
Collapse
Affiliation(s)
- Erin K. Purcell
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA; (Y.G.); (A.S.); (W.L.)
- Department of Biomedical Engineering, Michigan State University, East Lansing, MI 48824, USA;
- Neuroscience Program, Michigan State University, East Lansing, MI 48824, USA;
- Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - Michael F. Becker
- Fraunhofer USA Center Midwest, East Lansing, MI 48824, USA; (M.F.B.); (R.R.); (J.R.S.); (S.W.)
| | - Yue Guo
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA; (Y.G.); (A.S.); (W.L.)
| | - Seth A. Hara
- Division of Engineering, Mayo Clinic, Rochester, MN 55905, USA;
| | - Kip A. Ludwig
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA; (K.A.L.); (J.K.T.)
- Department of Neurosurgery, University of Wisconsin-Madison, Madison, WI 53792, USA
| | - Collin J. McKinney
- Department of Chemistry, Electronics Core Facility, University of North Carolina at Chapel Hill, Chapel Hill, NC 27514, USA;
| | - Elizabeth M. Monroe
- Department of Chemistry and Biochemistry, University of Nevada, Las Vegas, NV 89154, USA; (E.M.M.); (C.A.R.)
| | - Robert Rechenberg
- Fraunhofer USA Center Midwest, East Lansing, MI 48824, USA; (M.F.B.); (R.R.); (J.R.S.); (S.W.)
| | - Cory A. Rusinek
- Department of Chemistry and Biochemistry, University of Nevada, Las Vegas, NV 89154, USA; (E.M.M.); (C.A.R.)
| | - Akash Saxena
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA; (Y.G.); (A.S.); (W.L.)
- Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - James R. Siegenthaler
- Fraunhofer USA Center Midwest, East Lansing, MI 48824, USA; (M.F.B.); (R.R.); (J.R.S.); (S.W.)
| | - Caryl E. Sortwell
- Neuroscience Program, Michigan State University, East Lansing, MI 48824, USA;
- Department of Translational Neuroscience, College of Human Medicine, Michigan State University, Grand Rapids, MI 49503, USA
| | - Cort H. Thompson
- Department of Biomedical Engineering, Michigan State University, East Lansing, MI 48824, USA;
- Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
| | - James K. Trevathan
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA; (K.A.L.); (J.K.T.)
- Grainger Institute for Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Suzanne Witt
- Fraunhofer USA Center Midwest, East Lansing, MI 48824, USA; (M.F.B.); (R.R.); (J.R.S.); (S.W.)
| | - Wen Li
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA; (Y.G.); (A.S.); (W.L.)
- Department of Biomedical Engineering, Michigan State University, East Lansing, MI 48824, USA;
- Neuroscience Program, Michigan State University, East Lansing, MI 48824, USA;
- Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, MI 48824, USA
| |
Collapse
|
39
|
Bazany-Rodríguez IJ, Salomón-Flores MK, Viviano-Posadas AO, García-Eleno MA, Barroso-Flores J, Martínez-Otero D, Dorazco-González A. Chemosensing of neurotransmitters with selectivity and naked eye detection of l-DOPA based on fluorescent Zn(ii)-terpyridine bearing boronic acid complexes. Dalton Trans 2021; 50:4255-4269. [DOI: 10.1039/d0dt04228e] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A new range of fluorescent Zn(ii)-terpyridine complexes are described and studied in-depth as chemosensors for catecholamine-based neurotransmitters in pure water.
Collapse
Affiliation(s)
- Iván J. Bazany-Rodríguez
- Instituto de Química
- Universidad Nacional Autónoma de México
- Circuito Exterior, Ciudad Universitaria
- México
- Mexico
| | - María K. Salomón-Flores
- Instituto de Química
- Universidad Nacional Autónoma de México
- Circuito Exterior, Ciudad Universitaria
- México
- Mexico
| | | | - Marco A. García-Eleno
- Centro Conjunto de Investigación en Química Sustentable CCIQS UAEM-UNAM
- Facultad de Química
- Universidad Autónoma del Estado de México
- Carretera Toluca-Atlacomulco Km 14.5
- Toluca
| | - Joaquín Barroso-Flores
- Centro Conjunto de Investigación en Química Sustentable
- UAEM-UNAM
- Carretera Toluca-Atlacomulco Km 14.5
- Universidad Nacional Autónoma de México
| | - Diego Martínez-Otero
- Centro Conjunto de Investigación en Química Sustentable
- UAEM-UNAM
- Carretera Toluca-Atlacomulco Km 14.5
- Universidad Nacional Autónoma de México
| | - Alejandro Dorazco-González
- Instituto de Química
- Universidad Nacional Autónoma de México
- Circuito Exterior, Ciudad Universitaria
- México
- Mexico
| |
Collapse
|
40
|
Banerjee S, McCracken S, Hossain MF, Slaughter G. Electrochemical Detection of Neurotransmitters. BIOSENSORS 2020; 10:E101. [PMID: 32824869 PMCID: PMC7459656 DOI: 10.3390/bios10080101] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 08/13/2020] [Accepted: 08/17/2020] [Indexed: 01/15/2023]
Abstract
Neurotransmitters are important chemical messengers in the nervous system that play a crucial role in physiological and physical health. Abnormal levels of neurotransmitters have been correlated with physical, psychotic, and neurodegenerative diseases such as Alzheimer's, Parkinson's, dementia, addiction, depression, and schizophrenia. Although multiple neurotechnological approaches have been reported in the literature, the detection and monitoring of neurotransmitters in the brain remains a challenge and continues to garner significant attention. Neurotechnology that provides high-throughput, as well as fast and specific quantification of target analytes in the brain, without negatively impacting the implanted region is highly desired for the monitoring of the complex intercommunication of neurotransmitters. Therefore, it is crucial to develop clinical assessment techniques that are sensitive and reliable to monitor and modulate these chemical messengers and screen diseases. This review focuses on summarizing the current electrochemical measurement techniques that are capable of sensing neurotransmitters with high temporal resolution in real time. Advanced neurotransmitter sensing platforms that integrate nanomaterials and biorecognition elements are explored.
Collapse
Affiliation(s)
| | | | | | - Gymama Slaughter
- Frank Reidy Research Center for Bioelectrics, Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, VA 23508, USA; (S.B.); (S.M.); (M.F.H.)
| |
Collapse
|
41
|
π-Donor/π-Acceptor Interactions for the Encapsulation of Neurotransmitters on Functionalized Polysilicon-Based Microparticles. Pharmaceutics 2020; 12:pharmaceutics12080724. [PMID: 32752258 PMCID: PMC7463889 DOI: 10.3390/pharmaceutics12080724] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 07/28/2020] [Accepted: 07/29/2020] [Indexed: 12/11/2022] Open
Abstract
Bipyridinium salts, commonly known as viologens, are π-acceptor molecules that strongly interact with π-donor compounds, such as porphyrins or amino acids, leading their self-assembling. These properties have promoted us to functionalize polysilicon microparticles with bipyridinium salts for the encapsulation and release of π-donor compounds such as catecholamines and indolamines. In this work, the synthesis and characterization of four gemini-type amphiphilic bipyridinium salts (1·4PF6–4·4PF6), and their immobilization either non-covalently or covalently on polysilicon surfaces and microparticles have been achieved. More importantly, they act as hosts for the subsequent incorporation of π-donor neurotransmitters such as dopamine, serotonin, adrenaline or noradrenaline. Ultraviolet-visible absorption and fluorescence spectroscopies and high-performance liquid chromatography were used to detect the formation of the complex in solution. The immobilization of bipyridinium salts and neurotransmitter incorporation on polysilicon surfaces was corroborated by contact angle measurements. The reduction in the bipyridinium moiety and the subsequent release of the neurotransmitter was achieved using ascorbic acid, or Vitamin C, as a triggering agent. Quantification of neurotransmitter encapsulated and released from the microparticles was performed using high-performance liquid chromatography. The cytotoxicity and genotoxicity studies of the bipyridinium salt 1·4PF6, which was selected for the non-covalent functionalization of the microparticles, demonstrated its low toxicity in the mouse fibroblast cell line (3T3/NIH), the human liver carcinoma cell line (HepG2) and the human epithelial colorectal adenocarcinoma cell line (Caco-2).
Collapse
|
42
|
Sabry DA. Comparative study about ageing effect on retina and cerebellum of
Columba livia domestica. ACTA ZOOL-STOCKHOLM 2020. [DOI: 10.1111/azo.12347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Dalia A. Sabry
- Zoology Department Faculty of Science Mansoura University Mansoura Egypt
| |
Collapse
|