1
|
Mohamed R, Chou SF. Physicomechanical characterizations and in vitro release studies of electrospun ethyl cellulose fibers, solvent cast carboxymethyl cellulose films, and their composites. Int J Biol Macromol 2024; 267:131374. [PMID: 38582474 DOI: 10.1016/j.ijbiomac.2024.131374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 03/12/2024] [Accepted: 04/02/2024] [Indexed: 04/08/2024]
Abstract
Frequent change of wound dressings introduces wound inflammation and infections. In this study, we electrospun phenytoin (PHT) loaded ethyl cellulose (EC) microfibers and solvent cast tetracycline hydrochloride (TCH) loaded carboxymethyl cellulose (CMC) films with the aim to demonstrate tailorable in vitro drug release behaviors suitable for long-term use of wound dressings. Results from tensile testing showed a significant decrease in average elastic moduli from 8.8 ± 0.6 to 3.3 ± 0.3 MPa after incorporating PHT into EC fibers. PHT-loaded EC fibers displayed a slow and zero-ordered release up to 80 % of the total drug at 48 h, while TCH-loaded CMC films demonstrated a rapid and complete release within 30 min. Furthermore, drug-loaded EC/CMC composites were fabricated into fiber-in-film and fiber-on-film composites. Fiber-in-film composites showed stage release of TCH and PHT at 8 h, while fiber-on-film composites demonstrated simultaneous release of PHT and TCH with a prolonged release of TCH from CMC films. In general, electrospun PHT-loaded EC microfibers, solvent cast TCH-loaded CMC films, and their composites were studied to provide a fundamental scientific understanding on the novelty of the ability to modulate drug release characteristics based on the composite designs.
Collapse
Affiliation(s)
- Reham Mohamed
- Department of Mechanical Engineering, College of Engineering, The University of Texas at Tyler, Tyler, TX 75799, USA
| | - Shih-Feng Chou
- Department of Mechanical Engineering, College of Engineering, The University of Texas at Tyler, Tyler, TX 75799, USA.
| |
Collapse
|
2
|
Faglie A, Emerine R, Chou SF. Effects of Poloxamers as Excipients on the Physicomechanical Properties, Cellular Biocompatibility, and In Vitro Drug Release of Electrospun Polycaprolactone (PCL) Fibers. Polymers (Basel) 2023; 15:2997. [PMID: 37514386 PMCID: PMC10383550 DOI: 10.3390/polym15142997] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 06/29/2023] [Accepted: 06/29/2023] [Indexed: 07/30/2023] Open
Abstract
Electrospun microfibers are emerging as one of the advanced wound dressing materials for acute and/or chronic wounds, especially with their ability to carry drugs and excipients at a high loading while being able to deliver them in a controlled manner. Various attempts were made to include excipients in electrospun microfibers as wound dressing materials, and one of them is poloxamer, an amphiphilic polymer that exhibits wound debridement characteristics. In this study, we formulated two types of poloxamers (i.e., P188 and P338) at 30% (w/w) loading into electrospun polycaprolactone (PCL) fibers to evaluate their physicomechanical properties, biocompatibility, and in vitro drug release of a model drug. Our findings showed that the incorporation of poloxamers in the PCL solutions during electrospinning resulted in a greater "whipping" process for a larger fiber deposition area. These fibers were mechanically stiffer and stronger, but less ductile as compared to the PCL control fibers. The incorporation of poloxamers into electrospun PCL fibers reduced the surface hydrophobicity of fibers according to our water contact angle studies and in vitro degradation studies. The fibers' mechanical properties returned to those of the PCL control groups after "dumping" the poloxamers. Moreover, poloxamer-loaded PCL fibers accelerated the in vitro release of the model drug due to surface wettability. These poloxamer-loaded PCL fibers were biocompatible, as validated by MTT assays using A549 cells. Overall, we demonstrated the ability to achieve a high loading of poloxamers in electrospun fibers for wound dressing applications. This work provided the basic scientific understanding of materials science and bioengineering with an emphasis on the engineering applications of advanced wound dressings.
Collapse
Affiliation(s)
- Addison Faglie
- Department of Mechanical Engineering, College of Engineering, The University of Texas at Tyler, Tyler, TX 75799, USA
| | - Rachel Emerine
- Department of Mechanical Engineering, College of Engineering, The University of Texas at Tyler, Tyler, TX 75799, USA
| | - Shih-Feng Chou
- Department of Mechanical Engineering, College of Engineering, The University of Texas at Tyler, Tyler, TX 75799, USA
| |
Collapse
|
3
|
Meena M, Kerketta A, Tripathi M, Roy P, Jacob J. Thermally stable poly(urethane‐imide)s with enhanced hydrophilicity for waterproof‐breathable textile coatings. J Appl Polym Sci 2022. [DOI: 10.1002/app.52508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Mahipal Meena
- Centre for Fire, Explosive and Environment Safety DRDO Delhi India
- Department of Materials Science and Engineering Indian Institute of Technology Delhi India
| | - Anjlina Kerketta
- Centre for Fire, Explosive and Environment Safety DRDO Delhi India
| | | | - Prasun Roy
- Centre for Fire, Explosive and Environment Safety DRDO Delhi India
| | - Josemon Jacob
- Department of Materials Science and Engineering Indian Institute of Technology Delhi India
| |
Collapse
|
4
|
Rusu LC, Ardelean LC, Jitariu AA, Miu CA, Streian CG. An Insight into the Structural Diversity and Clinical Applicability of Polyurethanes in Biomedicine. Polymers (Basel) 2020; 12:polym12051197. [PMID: 32456335 PMCID: PMC7285236 DOI: 10.3390/polym12051197] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 05/13/2020] [Accepted: 05/22/2020] [Indexed: 01/16/2023] Open
Abstract
Due to their mechanical properties, ranging from flexible to hard materials, polyurethanes (PUs) have been widely used in many industrial and biomedical applications. PUs’ characteristics, along with their biocompatibility, make them successful biomaterials for short and medium-duration applications. The morphology of PUs includes two structural phases: hard and soft segments. Their high mechanical resistance featuresare determined by the hard segment, while the elastomeric behaviour is established by the soft segment. The most important biomedical applications of PUs include antibacterial surfaces and catheters, blood oxygenators, dialysis devices, stents, cardiac valves, vascular prostheses, bioadhesives/surgical dressings/pressure-sensitive adhesives, drug delivery systems, tissue engineering scaffolds and electrospinning, nerve generation, pacemaker lead insulation and coatings for breast implants. The diversity of polyurethane properties, due to the ease of bulk and surface modification, plays a vital role in their applications.
Collapse
Affiliation(s)
- Laura-Cristina Rusu
- Department of Oral Pathology, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu sq, 300041 Timisoara, Romania;
| | - Lavinia Cosmina Ardelean
- Department of Technology of Materials and Devices in Dental Medicine, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu sq, 300041 Timisoara, Romania
- Correspondence:
| | - Adriana-Andreea Jitariu
- Department of Microscopic Morphology/Histology and Angiogenesis Research Center Timisoara, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu sq, 300041 Timisoara, Romania;
| | - Catalin Adrian Miu
- 3rd Department of Orthopaedics-Traumatology, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu sq, 300041 Timisoara, Romania;
| | - Caius Glad Streian
- Department of Cardiac Surgery, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu sq, 300041 Timisoara, Romania;
| |
Collapse
|
5
|
Singha P, Goudie MJ, Liu Q, Hopkins S, Brown N, Schmiedt CW, Locklin J, Handa H. Multipronged Approach to Combat Catheter-Associated Infections and Thrombosis by Combining Nitric Oxide and a Polyzwitterion: a 7 Day In Vivo Study in a Rabbit Model. ACS APPLIED MATERIALS & INTERFACES 2020; 12:9070-9079. [PMID: 32009376 PMCID: PMC7946114 DOI: 10.1021/acsami.9b22442] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The development of nonfouling and antimicrobial materials has shown great promise for reducing thrombosis and infection associated with medical devices with aims of improving device safety and decreasing the frequency of antibiotic administration. Here, the design of an antimicrobial, anti-inflammatory, and antithrombotic vascular catheter is assessed in vivo over 7 d in a rabbit model. Antimicrobial and antithrombotic activity is achieved through the integration of a nitric oxide donor, while the nonfouling surface is achieved using a covalently bound phosphorylcholine-based polyzwitterionic copolymer topcoat. The effect of sterilization on the nonfouling nature and nitric oxide release is presented. The catheters reduced viability of Staphylococcus aureus in long-term studies (7 d in a CDC bioreactor) and inflammation in the 7 d rabbit model. Overall, this approach provides a robust method for decreasing thrombosis, inflammation, and infections associated with vascular catheters.
Collapse
Affiliation(s)
- Priyadarshini Singha
- School of Chemical, Materials and Biomedical Engineering , The University of Georgia , Athens , Georgia 30602 , United States
| | - Marcus J Goudie
- School of Chemical, Materials and Biomedical Engineering , The University of Georgia , Athens , Georgia 30602 , United States
| | - Qiaohong Liu
- Department of Chemistry , The University of Georgia , Athens , Georgia 30602 , United States
| | - Sean Hopkins
- School of Chemical, Materials and Biomedical Engineering , The University of Georgia , Athens , Georgia 30602 , United States
| | - Nettie Brown
- School of Chemical, Materials and Biomedical Engineering , The University of Georgia , Athens , Georgia 30602 , United States
| | - Chad W Schmiedt
- College of Veterinary Medicine , The University of Georgia , Athens , Georgia 30602 , United States
| | - Jason Locklin
- School of Chemical, Materials and Biomedical Engineering , The University of Georgia , Athens , Georgia 30602 , United States
- Department of Chemistry , The University of Georgia , Athens , Georgia 30602 , United States
| | - Hitesh Handa
- School of Chemical, Materials and Biomedical Engineering , The University of Georgia , Athens , Georgia 30602 , United States
| |
Collapse
|
6
|
Chou SF, Caltrider BA, Azghani A, Neuenschwander PF. Inhibition of Platelet Adhesion from Surface Modified Polyurethane Membranes. BIOMEDICAL JOURNAL OF SCIENTIFIC & TECHNICAL RESEARCH 2020; 32:24988-24993. [PMID: 33738429 PMCID: PMC7968869 DOI: 10.26717/bjstr.2020.32.005247] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Coronary thrombosis is one of the leading causes of mortality and morbidity in cardiovascular diseases, and patients who received vascular stent treatments are likely to suffer from restenosis due to tissue damage from stenting procedures (extrinsic pathway) and/or presence of unregulated factor XII (intrinsic pathway). Regardless of the pathway, coagulation factors and exposed collagen activate the G-protein-coupled receptors located at the plasma membrane of the resting platelets resulting in the change of their shapes with protrusions of filopodia and lamellipodia for surface adhesion. In this mini review, we discussed the mechanisms involved in platelet activation, adhesion, and aggregation. More importantly, we reviewed the use of polyurethane membranes with modified surface functional groups to down-regulate platelet adhesion and aggregation activities. Polyurethane membranes with hydrophilic and negatively charged surface properties showed a reduced αIIb-β3 signaling from the activated platelets, resulting in the decrease of platelet adhesion and aggregation. The use of polyurethane membranes with modified surface properties as coatings on vascular stents provides an engineering approach to mitigate blood clotting associated with restenosis.
Collapse
Affiliation(s)
- Shih-Feng Chou
- Department of Mechanical Engineering, The University of Texas at Tyler, USA
| | | | - Ali Azghani
- Department of Biology, The University of Texas at Tyler, USA
| | - Pierre F Neuenschwander
- School of Medical Biological Sciences, The University of Texas Health Science Center at Tyler, USA
| |
Collapse
|