1
|
Feng Y, Yi K, Gong F, Zhang Y, Shan X, Ji X, Zhou F, He Z. Ultra-sensitive detection of SARS-CoV-2 S1 protein by coupling rolling circle amplification with poly(N-isopropylacrylamide)-based sandwich-type assay. Talanta 2024; 279:126572. [PMID: 39024855 DOI: 10.1016/j.talanta.2024.126572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Revised: 07/12/2024] [Accepted: 07/13/2024] [Indexed: 07/20/2024]
Abstract
In the past few years, the COVID-19 pandemic, caused by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) seriously threatens global public health security due to its high contagiousness. It remains of vital importance to develop a rapid and sensitive assay for SARS-CoV-2. In this work, we proposed a sandwich-type assay based on poly(N-isopropylacrylamide) (PNIPAM), allowing efficient detection of the SARS-CoV-2 S1 protein in the homogeneous solution. Firstly, a direct sandwich-type assay was established with a linear range of 0.2-2 μg/mL and a limit of detection (LOD) of 0.11 μg/mL, which could realize rapid detection in about 1 h. Furthermore, the sandwich-type assay coupled with rolling circle amplification (RCA) obtained an increase in sensitivity of 5.9 × 104 folds with a wide linear range of 0.01 - 100 ng/mL and a LOD of 1.88 pg/mL. The average recoveries in unpretreated saliva were 90 %-113.0 %, indicating the potential of the developed method for application in practical samples. Given the high selectivity and sensitivity of the developed method, it has a significant potential for rapid and early detection of SARS-CoV-2.
Collapse
Affiliation(s)
- Yu Feng
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Kebing Yi
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Feng Gong
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Yaran Zhang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Xiaoyun Shan
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China
| | - Xinghu Ji
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China.
| | - Fuxiang Zhou
- Department of Radiation and Medical Oncology, Hubei Key Laboratory of Tumor Biological Behaviors, and Hubei Cancer Clinical Study Center, Zhongnan Hospital of Wuhan University, Wuhan, 430072, China
| | - Zhike He
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China; Department of Radiation and Medical Oncology, Hubei Key Laboratory of Tumor Biological Behaviors, and Hubei Cancer Clinical Study Center, Zhongnan Hospital of Wuhan University, Wuhan, 430072, China.
| |
Collapse
|
2
|
Venkatesh M, Parthasarathy P. Al 2O 3/ZrO 2 dual-dielectric Gr/CNT nanoribbon vertical tunnel FET based biosensor for genomic classification and S-protein detection in SARS-CoV-2. Heliyon 2024; 10:e30077. [PMID: 38707330 PMCID: PMC11066398 DOI: 10.1016/j.heliyon.2024.e30077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 04/05/2024] [Accepted: 04/18/2024] [Indexed: 05/07/2024] Open
Abstract
The ongoing genetic mutation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) possesses the capacity to inadvertently lead to an increase in both the rates of transmission and mortality. In this study, we showcase the use of an Al2O3/ZrO2 Dual-Dielectric Gr/CNT Nanoribbon vertical tunnel field-effect transistor biosensor for the purpose of detecting spike proteins of SARS-CoV-2 in clinical samples. The proteins mentioned above are situated within the protein capsids of the virus. The effectiveness of the suggested detector has been assessed through measurements of the alteration in current drain. The present study utilizes the dielectric coefficient analogue of viral proteins as a substitute for biomolecules that exhibit internal hybridization nanogaps. The high sensitivity of the suggested detector, as evaluated on a scale ranging from 0 to 115, suggests its potential as a high-quality sensing instrument. The purpose of this study is to examine the sensitivity of DNA charge density with the aim of identifying any alterations in the virus that may impact its ability to spread and infect humans. The chromosomal composition of SARS-CoV-2 has been determined. The CMC Research Centre, situated in Vellore, Tamil Nadu, India, conducted an examination of SARS-CoV-2 samples. The scientists possess the capability to do genome sequencing on these specimens, so facilitating the examination of mutation patterns and the dispersion of different clades. A total of 250 different mutations were found out of the 600 sequences that were evaluated. The sequencing data consists of a complete collection of 250 distinct variants, including 150 missense mutations, 80 synonymous mutations, 15 mutations in noncoding regions, and 5 deletions. The comprehension of genetic variety is significantly dependent on these mutations. The proposed detector is connected to a variety of previously documented biosensors based on field-effect transistors (FETs), which are employed for the examination of genetic modifications.
Collapse
Affiliation(s)
- M. Venkatesh
- Department of Electronics and Communication Engineering, CMR Institute of Technology, Bengaluru, Karnataka, India, 560037
| | - P. Parthasarathy
- Department of Electronics and Communication Engineering, CMR Institute of Technology, Bengaluru, Karnataka, India, 560037
| |
Collapse
|
3
|
Kim YJ, Min J. Advances in nanobiosensors during the COVID-19 pandemic and future perspectives for the post-COVID era. NANO CONVERGENCE 2024; 11:3. [PMID: 38206526 PMCID: PMC10784265 DOI: 10.1186/s40580-023-00410-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 12/07/2023] [Indexed: 01/12/2024]
Abstract
The unprecedented threat of the highly contagious virus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes exponentially increased infections of coronavirus disease 2019 (COVID-19), highlights the weak spots of the current diagnostic toolbox. In the midst of catastrophe, nanobiosensors offer a new opportunity as an alternative tool to fill a gap among molecular tests, rapid antigen tests, and serological tests. Nanobiosensors surpass the potential of antigen tests because of their enhanced sensitivity, thus enabling us to see antigens as stable and easy-to-access targets. During the first three years of the COVID-19 pandemic, a substantial number of studies have reported nanobiosensors for the detection of SARS-CoV-2 antigens. The number of articles on nanobiosensors and SARS-CoV-2 exceeds the amount of nanobiosensor research on detecting previous infectious diseases, from influenza to SARS-CoV and MERS-CoV. This unprecedented publishing pace also implies the significance of SARS-CoV-2 and the present pandemic. In this review, 158 studies reporting nanobiosensors for detecting SARS-CoV-2 antigens are collected to discuss the current challenges of nanobiosensors using the criteria of point-of-care (POC) diagnostics along with COVID-specific issues. These advances and lessons during the pandemic pave the way for preparing for the post-COVID era and potential upcoming infectious diseases.
Collapse
Affiliation(s)
- Young Jun Kim
- School of Integrative Engineering, Chung-Ang University, Heukseok-Dong, Dongjak-Gu, Seoul, 06974, Republic of Korea
| | - Junhong Min
- School of Integrative Engineering, Chung-Ang University, Heukseok-Dong, Dongjak-Gu, Seoul, 06974, Republic of Korea.
| |
Collapse
|
4
|
Vilca-Alosilla JJ, Candia-Puma MA, Coronel-Monje K, Goyzueta-Mamani LD, Galdino AS, Machado-de-Ávila RA, Giunchetti RC, Ferraz Coelho EA, Chávez-Fumagalli MA. A Systematic Review and Meta-Analysis Comparing the Diagnostic Accuracy Tests of COVID-19. Diagnostics (Basel) 2023; 13:diagnostics13091549. [PMID: 37174941 PMCID: PMC10177430 DOI: 10.3390/diagnostics13091549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 04/06/2023] [Accepted: 04/11/2023] [Indexed: 05/15/2023] Open
Abstract
In this paper, we present a systematic review and meta-analysis that aims to evaluate the reliability of coronavirus disease diagnostic tests in 2019 (COVID-19). This article seeks to describe the scientific discoveries made because of diagnostic tests conducted in recent years during the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. Between 2020 and 2021, searches for published papers on the COVID-19 diagnostic were made in the PubMed database. Ninety-nine scientific articles that satisfied the requirements were analyzed and included in the meta-analysis, and the specificity and sensitivity of the diagnostic accuracy were assessed. When compared to serological tests such as the enzyme-linked immunosorbent assay (ELISA), chemiluminescence immunoassay (CLIA), lateral flow immunoassay (LFIA), and chemiluminescent microparticle immunoassay (CMIA), molecular tests such as reverse transcription polymerase chain reaction (RT-PCR), reverse transcription loop-mediated isothermal amplification (RT-LAMP), and clustered regularly interspaced short palindromic repeats (CRISPR) performed better in terms of sensitivity and specificity. Additionally, the area under the curve restricted to the false-positive rates (AUCFPR) of 0.984 obtained by the antiviral neutralization bioassay (ANB) diagnostic test revealed significant potential for the identification of COVID-19. It has been established that the various diagnostic tests have been effectively adapted for the detection of SARS-CoV-2; nevertheless, their performance still must be enhanced to contain potential COVID-19 outbreaks, which will also help contain potential infectious agent outbreaks in the future.
Collapse
Affiliation(s)
- Juan Jeferson Vilca-Alosilla
- Computational Biology and Chemistry Research Group, Vicerrectorado de Investigación, Universidad Católica de Santa María, Arequipa 04000, Peru
- Facultad de Ciencias Farmacéuticas, Bioquímicas y Biotecnológicas, Universidad Católica de Santa María, Arequipa 04000, Peru
| | - Mayron Antonio Candia-Puma
- Computational Biology and Chemistry Research Group, Vicerrectorado de Investigación, Universidad Católica de Santa María, Arequipa 04000, Peru
- Facultad de Ciencias Farmacéuticas, Bioquímicas y Biotecnológicas, Universidad Católica de Santa María, Arequipa 04000, Peru
| | - Katiusca Coronel-Monje
- Computational Biology and Chemistry Research Group, Vicerrectorado de Investigación, Universidad Católica de Santa María, Arequipa 04000, Peru
- Facultad de Ciencias Farmacéuticas, Bioquímicas y Biotecnológicas, Universidad Católica de Santa María, Arequipa 04000, Peru
| | - Luis Daniel Goyzueta-Mamani
- Computational Biology and Chemistry Research Group, Vicerrectorado de Investigación, Universidad Católica de Santa María, Arequipa 04000, Peru
- Sustainable Innovative Biomaterials Department, Le Qara Research Center, Arequipa 04000, Peru
| | - Alexsandro Sobreira Galdino
- Laboratório de Biotecnologia de Microrganismos, Universidade Federal São João Del-Rei, Divinópolis 35501-296, MG, Brazil
| | | | - Rodolfo Cordeiro Giunchetti
- Laboratório de Biologia das Interações Celulares, Instituto de Ciências Biológicas, Universidade Federal de Minas Gerais, Belo Horizonte 31270-901, MG, Brazil
- Instituto Nacional de Ciência e Tecnologia em Doenças Tropicais, INCT-DT, Salvador 40015-970, BA, Brazil
| | - Eduardo Antonio Ferraz Coelho
- Programa de Pós-Graduação em Ciências da Saúde: Infectologia e Medicina Tropical, Faculdade de Medicina, Universidade Federal de Minas Gerais, Belo Horizonte 31270-901, MG, Brazil
- Departamento de Patologia Clínica, COLTEC, Universidade Federal de Minas Gerais, Belo Horizonte 31270-901, MG, Brazil
| | - Miguel Angel Chávez-Fumagalli
- Computational Biology and Chemistry Research Group, Vicerrectorado de Investigación, Universidad Católica de Santa María, Arequipa 04000, Peru
| |
Collapse
|
5
|
Wang PG, Li BR, Wang YL, Wu CC, Chen JC. Application of aminobenzoic acid electrodeposited screen-printed carbon electrode in the beta-amyloid electrochemical impedance spectroscopy immunoassay. Talanta 2023; 254:124154. [PMID: 36527913 DOI: 10.1016/j.talanta.2022.124154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 11/21/2022] [Accepted: 11/28/2022] [Indexed: 12/23/2022]
Abstract
Alzheimer's disease (AD) is one of the important neurodegenerative diseases, in the modern aging society, it has become an issue people need to work on. Of the pathogenic factor which leads to AD, beta-amyloid (Aβ) is the most important one. It can form the senile plaque which aggregates in the neuron and interrupts the signal transmission. This research is based on the electrochemical system and screen-printed carbon electrode (SPCE) incorporated with pretreatment, electrodeposition, electrochemical impedance spectroscopy (EIS), antibody, and blocking agent. This immunosensor is applied to detect the different concentrations of Aβ. The standard curve between electrical impedance and concentration of Aβ is calculated. The specificity of the immunosensor is tested. This survey optimizes the electrodeposition condition for 4-aminobenzoic acid (4-ABA) and the parameter for antibody and blocking agents. This study fabricates a more dense, uniform, and stable film of 4-ABA. This sensor presents a range of detection from 1 fg/ml to 100 pg/ml and a limit of detection to 3.84 fg/ml. This sensor can identify the isoform of Aβ. This research shortens the fabricating time to 3.5 h. This study fabricates a label-free and low-cost immunosensor for Aβ with a short fabricating time, high stability, wide range of detection, low limit of detection, and good specificity. The impedance of the carbon printed electrodes is very high and is always measured by its current but this study provides a fabrication technique for high-efficiency carbon printed electrodes for electrochemical impedance spectroscopy sensing.
Collapse
Affiliation(s)
- Ping-Ghun Wang
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu City, 300, Taiwan
| | - Bor-Ran Li
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu City, 300, Taiwan
| | - Yu-Lin Wang
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu City, 300, Taiwan; Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu City, 300, Taiwan
| | - Ching-Chou Wu
- Department of Bio-industrial Mechatronics Engineering, National Chung Hsing University, Taichung City, 402, Taiwan; Innovation and Development Center of Sustainable Agriculture, National Chung Hsing University, Taichung City, 402, Taiwan
| | - Jung-Chih Chen
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu City, 300, Taiwan; Department of Electronics and Electrical Engineering, National Yang Ming Chiao Tung University, Hsinchu City, 300, Taiwan; Catholic Mercy Hospital, Catholic Mercy Medical Foundation, Hsinchu County, 303, Taiwan; Medical Device Innovation & Translation Center, National Yang Ming Chiao Tung University, Hsinchu City, 300, Taiwan.
| |
Collapse
|
6
|
Truong PL, Yin Y, Lee D, Ko SH. Advancement in COVID-19 detection using nanomaterial-based biosensors. EXPLORATION (BEIJING, CHINA) 2023; 3:20210232. [PMID: 37323622 PMCID: PMC10191025 DOI: 10.1002/exp.20210232] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 05/11/2022] [Indexed: 06/17/2023]
Abstract
Coronavirus disease 2019 (COVID-19) pandemic has exemplified how viral growth and transmission are a significant threat to global biosecurity. The early detection and treatment of viral infections is the top priority to prevent fresh waves and control the pandemic. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been identified through several conventional molecular methodologies that are time-consuming and require high-skill labor, apparatus, and biochemical reagents but have a low detection accuracy. These bottlenecks hamper conventional methods from resolving the COVID-19 emergency. However, interdisciplinary advances in nanomaterials and biotechnology, such as nanomaterials-based biosensors, have opened new avenues for rapid and ultrasensitive detection of pathogens in the field of healthcare. Many updated nanomaterials-based biosensors, namely electrochemical, field-effect transistor, plasmonic, and colorimetric biosensors, employ nucleic acid and antigen-antibody interactions for SARS-CoV-2 detection in a highly efficient, reliable, sensitive, and rapid manner. This systematic review summarizes the mechanisms and characteristics of nanomaterials-based biosensors for SARS-CoV-2 detection. Moreover, continuing challenges and emerging trends in biosensor development are also discussed.
Collapse
Affiliation(s)
- Phuoc Loc Truong
- Laser and Thermal Engineering LabDepartment of Mechanical EngineeringGachon UniversitySeongnamKorea
| | - Yiming Yin
- New Materials InstituteDepartment of MechanicalMaterials and Manufacturing EngineeringUniversity of Nottingham Ningbo ChinaNingboChina
- Applied Nano and Thermal Science LabDepartment of Mechanical EngineeringSeoul National UniversityGwanak‐guSeoulKorea
| | - Daeho Lee
- Laser and Thermal Engineering LabDepartment of Mechanical EngineeringGachon UniversitySeongnamKorea
| | - Seung Hwan Ko
- Applied Nano and Thermal Science LabDepartment of Mechanical EngineeringSeoul National UniversityGwanak‐guSeoulKorea
- Institute of Advanced Machinery and Design (SNU‐IAMD)/Institute of Engineering ResearchSeoul National UniversityGwanak‐guSeoulKorea
| |
Collapse
|
7
|
Clark K, Schenkel MS, Pittman TW, Samper IC, Anderson LBR, Khamcharoen W, Elmegerhi S, Perera R, Siangproh W, Kennan AJ, Geiss BJ, Dandy DS, Henry CS. Electrochemical Capillary Driven Immunoassay for Detection of SARS-CoV-2. ACS MEASUREMENT SCIENCE AU 2022; 2:584-594. [PMID: 36570470 PMCID: PMC9469961 DOI: 10.1021/acsmeasuresciau.2c00037] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 08/09/2022] [Accepted: 08/16/2022] [Indexed: 05/28/2023]
Abstract
The COVID-19 pandemic focused attention on a pressing need for fast, accurate, and low-cost diagnostic tests. This work presents an electrochemical capillary driven immunoassay (eCaDI) developed to detect SARS-CoV-2 nucleocapsid (N) protein. The low-cost flow device is made of polyethylene terephthalate (PET) and adhesive films. Upon addition of a sample, reagents and washes are sequentially delivered to an integrated screen-printed carbon electrode for detection, thus automating a full sandwich immunoassay with a single end-user step. The modified electrodes are sensitive and selective for SARS-CoV-2 N protein and stable for over 7 weeks. The eCaDI was tested with influenza A and Sindbis virus and proved to be selective. The eCaDI was also successfully applied to detect nine different SARS-CoV-2 variants, including Omicron.
Collapse
Affiliation(s)
- Kaylee
M. Clark
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Melissa S. Schenkel
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Trey W. Pittman
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Isabelle C. Samper
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department
of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Loran B. R. Anderson
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
| | - Wisarut Khamcharoen
- Department
of Chemistry, Faculty of Science, Srinakharinwirot
University, Bangkok 10110, Thailand
| | - Suad Elmegerhi
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
| | - Rushika Perera
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
| | - Weena Siangproh
- Department
of Chemistry, Faculty of Science, Srinakharinwirot
University, Bangkok 10110, Thailand
| | - Alan J. Kennan
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Brian J. Geiss
- Department
of Microbiology, Immunology, and Pathology, Colorado State University, Fort
Collins, Colorado 80523, United States
- School
of Biomedical Engineering, Colorado State
University, Fort Collins, Colorado 80523, United States
| | - David S. Dandy
- Department
of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
- School
of Biomedical Engineering, Colorado State
University, Fort Collins, Colorado 80523, United States
| | - Charles S. Henry
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department
of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
- School
of Biomedical Engineering, Colorado State
University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
8
|
Nihal S, Guppy-Coles K, Gholami MD, Punyadeera C, Izake EL. Towards Label-free detection of viral disease agents through their cell surface proteins: Rapid screening SARS-CoV-2 in biological specimens. SLAS DISCOVERY 2022; 27:331-336. [PMID: 35667647 PMCID: PMC9166287 DOI: 10.1016/j.slasd.2022.06.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Revised: 05/27/2022] [Accepted: 06/01/2022] [Indexed: 11/28/2022]
Abstract
Current methods for the screening of viral infections in clinical settings, such as reverse transcription polymerase chain reaction (RT-qPCR) and enzyme-linked immunosorbent assay (ELISA), are expensive, time-consuming, require trained personnel and sophisticated instruments. Therefore, novel sensors that can save time and cost are required specially in remote areas and developing countries that may lack the advanced scientific infrastructure for this task. In this work, we present a sensitive, and highly specific biosensing approach for the detection of harmful viruses that have cysteine residues within the structure of their cell surface proteins. We utilized new method for the rapid screening of SARS-CoV-2 virus in biological fluids through its S1 protein by surface enhanced Raman spectroscopy (SERS). The protein is captured from aqueous solutions and biological specimens using a target-specific extractor substrate. The structure of the purified protein is then modified to convert it into a bio-thiol by breaking the disulfide bonds and freeing up the sulfhydryl (SH) groups of the cysteine residues. The formed biothiol chemisorbs favourably onto a highly sensitive plasmonic sensor and probed by a handheld Raman device in few seconds. The new method was used to screen the S1 protein in aqueous medium, spiked human blood plasma, mucus, and saliva samples down to 150 fg/L. The label-free SERS biosensing method has strong potential for the fingerprint identification many viruses (e.g. the human immunodeficiency virus, the human polyomavirus, the human papilloma virus, the adeno associated viruses, the enteroviruses) through the cysteine residues of their capsid proteins. The new method can be applied at points of care (POC) in remote areas and developing countries lacking sophisticated scientific infrastructure.
Collapse
|
9
|
Abstract
We have engineered a cell that can be used for diagnosing active severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections. Isolation of individuals with active infections offers an effective solution for mitigating pandemics. However, the implementation of this practice requires robust infrastructure for rapid and intuitive testing, which is currently missing in our communities. To address this need, we engineered a fast-growing cell line into a cell-based antigen test platform for emerging viruses, i.e., DxCell, that can be rapidly deployed in decentralized health care facilities for continuous testing. The technology was characterized using cells engineered to present spike glycoprotein of SARS-CoV-2 (SARS-CoV-2-Sgp-cells) and Calu-3 host cells infected with competent SARS-CoV-2. Preclinical validation was conducted by directly incubating the DxCell with oropharyngeal swabs from mice infected with SARS-CoV-2. No sample preparation steps are necessary. The DxCell quantitatively detected the SARS-CoV-2-Sgp-cells within 1 h (P < 0.02). Reporter signal was proportional to the number of SARS-CoV-2-Sgp-cells, which represents the infection burden. The SARS-CoV-2 DxCell antigen test was benchmarked against quantitative PCR (qPCR) test and accurately differentiated between infected (n = 8) and control samples (n = 3) (P < 0.05). To demonstrate the broad applicability of the platform, we successfully redirected its specificity and tested its sensing function with cells engineered to present antigens from other viruses. In conclusion, we have developed an antigen test platform that capitalizes on the two innate functions of the cell, self-replication and activation-induced cell signaling. These provide the DxCell key advantages over existing technologies, e.g., label-free testing without sample processing, and will facilitate its implementation in decentralized health care facilities. IMPORTANCE Pandemic mitigation requires continuous testing of symptomatic or asymptomatic individuals with rapid turnaround time, and lack of this capability in our community has prolonged pandemic duration leading to obliteration of world economies. The DxCell platform is a cell-based self-replicative antigen test that detects molecular signatures of the target pathogen and can be distributed in small quantities to testing facilities for expansion on site to the desired volume. In this work, we directed this platform to target SARS-CoV-2. Unlike the PCR detection of viral mRNA that requires trained personnel, the DxCell does not require any sample preparation or signal amplification step and introduces an opportunity for a decentralized testing network.
Collapse
|
10
|
Georgas A, Agiannis K, Papakosta V, Priftis P, Angelopoulos S, Ferraro A, Hristoforou E. A Biosensor Platform for Point-of-Care SARS-CoV-2 Screening. BIOSENSORS 2022; 12:487. [PMID: 35884290 PMCID: PMC9312522 DOI: 10.3390/bios12070487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 06/22/2022] [Accepted: 07/01/2022] [Indexed: 11/16/2022]
Abstract
The COVID-19 pandemic remains a constant threat to human health, the economy, and social relations. Scientists around the world are constantly looking for new technological tools to deal with the pandemic. Such tools are the rapid virus detection tests, which are constantly evolving and optimizing. This paper presents a biosensor platform for the rapid detection of spike protein both in laboratory conditions and in swab samples from hospitalized patients. It is a continuation and improvement of our previous work and consists of a microcontroller-based readout circuit, which measures the capacitance change generated in an interdigitated electrode transducer by the presence either of sole spike protein or the presence of SARS-CoV-2 particles in swab samples. The circuit efficiency is calibrated by its correlation with the capacitance measurement of an LCR (inductance (L), capacitance (C), and resistance (R)) meter. The test result is made available in less than 2 min through the microcontroller's LCD (liquid-crystal display) screen, whereas at the same time, the collected data are sent wirelessly to a mobile application interface. The novelty of this research lies in the potential it offers for continuous and effective screening of SARS-CoV-2 patients, which is facilitated and enhanced, providing big data statistics of COVID-19 in terms of space and time. This device can be used by individuals for SARS-CoV-2 testing at home, by health professionals for patient monitoring, and by public health agencies for monitoring the spatio-temporal spread of the virus.
Collapse
Affiliation(s)
- Antonios Georgas
- School of Electrical and Computer Engineering, National Technical University of Athens, 15780 Athens, Greece; (K.A.); (V.P.); (P.P.); (S.A.); (A.F.); (E.H.)
| | | | | | | | | | | | | |
Collapse
|
11
|
Xu B, Tang H, Weng Y, Jones VS, Luo S, Cho CY, Lin Y, Fang J, Song X, Huang R. Development and evaluation of time-resolved fluorescent immunochromatographic assay for quantitative detection of SARS-CoV-2 spike antigen. J Clin Lab Anal 2022; 36:e24513. [PMID: 35692032 PMCID: PMC9279991 DOI: 10.1002/jcla.24513] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 03/28/2022] [Accepted: 04/25/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND The spread of COVID-19 worldwide caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has necessitated efficient, sensitive diagnostic methods to identify infected people. We report on the development of a rapid 15-minute time-resolved fluorescent (TRF) lateral flow immunochromatographic assay for the quantitative detection of the SARS-CoV-2 spike protein receptor-binding domain (S1-RBD). OBJECTIVES Our objective was to develop an efficient method of detecting SARS-CoV-2 within 15 min of sample collection. METHODS We constructed and evaluated a portable, disposable lateral flow device, which detected the S1-RBD protein directly in nasopharyngeal swab samples. The device emits a fluorescent signal in the presence of S1-RBD, which can be captured by an automated TRF instrument. RESULTS The TRF lateral flow assay signal was linear from 0 to 20 ng/ml and demonstrated high accuracy and reproducibility. When evaluated with clinical nasopharyngeal swabs, the assay was performed at >80% sensitivity, >84% specificity, and > 82% accuracy for detection of the S1-RBD antigen. CONCLUSION The new S1-RBD antigen test is a rapid (15 min), sensitive, and specific assay that requires minimal sample preparation. Critically, the assay correlated closely with PCR-based methodology in nasopharyngeal swab samples, showing that the detected S1-RBD antigen levels correlate with SARS-CoV-2 virus load. Therefore, the new TRF lateral flow test for S1-RBD has potential application in point-of-care settings.
Collapse
Affiliation(s)
| | - Hao Tang
- RayBiotech, GuangzhouGuangzhouChina
- RayBiotech LifePeachtree CornersGeorgiaUSA
| | | | | | - Shuhong Luo
- RayBiotech, GuangzhouGuangzhouChina
- RayBiotech LifePeachtree CornersGeorgiaUSA
| | | | - Yongping Lin
- The First Affiliated Hospital of Guangzhou Medical UniversityGuangzhouChina
| | - Jianmin Fang
- RayBiotech, GuangzhouGuangzhouChina
- RayBiotech LifePeachtree CornersGeorgiaUSA
| | | | - Ruo‐Pan Huang
- RayBiotech, GuangzhouGuangzhouChina
- RayBiotech LifePeachtree CornersGeorgiaUSA
- The First Affiliated Hospital of Guangzhou Medical UniversityGuangzhouChina
- South China Biochip Research CenterGuangzhouChina
| |
Collapse
|
12
|
Ultra-Fast and Sensitive Screening for Antibodies against the SARS-CoV-2 S1 Spike Antigen with a Portable Bioelectric Biosensor. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10070254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
As a consequence of the progress of the global vaccination against the COVID-19 disease, fast, accurate and affordable assays are needed for monitoring the efficiency of developing immunity against the coronavirus at the population level. In this context, we herewith report the proof-of-concept development of an innovative bioelectric biosensor for the ultra-detection (in less than three minutes) of IgG antibodies against the SARS-CoV-2 S1 spike antigen. The biosensor comprises a disposable set of screen-printed electrodes upon which are immobilized cells engineered to bear the S1 protein on their surface. When anti-S1 antibodies are presented to the engineered cell population, a rapid, specific, and selective change of the cell membrane potential occurs; this is in turn recorded by a bespoke portable potentiometer. End results are communicated via Bluetooth to a smartphone equipped with a customized user interface. By using the novel biosensor, anti-S1 antibodies could be detected at concentrations as low as 5 ng/mL. In a preliminary clinical trial, positive results were derived from patients vaccinated or previously infected by the virus. Selectivity over other respiratory viruses was demonstrated by the lack of cross-reactivity to antibodies against rhinovirus. After further clinical validation and extension to also screen IgM, IgA and possible neutralizing antibodies, our approach is intended to facilitate the mass and reliable detection of antibodies in the early stages following vaccination and to monitor the duration and level of acquired immunity both in a clinical and self-testing environment.
Collapse
|
13
|
Lan Y, He B, Tan CS, Ming D. Applications of Smartphone-Based Aptasensor for Diverse Targets Detection. BIOSENSORS 2022; 12:bios12070477. [PMID: 35884280 PMCID: PMC9312806 DOI: 10.3390/bios12070477] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 06/27/2022] [Accepted: 06/27/2022] [Indexed: 12/17/2022]
Abstract
Aptamers are a particular class of functional recognition ligands with high specificity and affinity to their targets. As the candidate recognition layer of biosensors, aptamers can be used to sense biomolecules. Aptasensors, aptamer-based biosensors, have been demonstrated to be specific, sensitive, and cost-effective. Furthermore, smartphone-based devices have shown their advantages in binding to aptasensors for point-of-care testing (POCT), which offers an immediate or spontaneous responding time for biological testing. This review describes smartphone-based aptasensors to detect various targets such as metal ions, nucleic acids, proteins, and cells. Additionally, the focus is also on aptasensors-related technologies and configurations.
Collapse
Affiliation(s)
- Ying Lan
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China; (Y.L.); (B.H.)
| | - Baixun He
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China; (Y.L.); (B.H.)
| | - Cherie S. Tan
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China; (Y.L.); (B.H.)
- Tianjin Key Laboratory of Brain Science and Neuroengineering, Tianjin 300072, China
- Correspondence: (C.S.T.); (D.M.)
| | - Dong Ming
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin 300072, China; (Y.L.); (B.H.)
- Tianjin Key Laboratory of Brain Science and Neuroengineering, Tianjin 300072, China
- Department of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Correspondence: (C.S.T.); (D.M.)
| |
Collapse
|
14
|
Georgas A, Lampas E, Houhoula DP, Skoufias A, Patsilinakos S, Tsafaridis I, Patrinos GP, Adamopoulos N, Ferraro A, Hristoforou E. ACE2-based capacitance sensor for rapid native SARS-CoV-2 detection in biological fluids and its correlation with real-time PCR. Biosens Bioelectron 2022; 202:114021. [PMID: 35092924 PMCID: PMC8776344 DOI: 10.1016/j.bios.2022.114021] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 01/13/2022] [Accepted: 01/17/2022] [Indexed: 12/14/2022]
Abstract
The spread of the SARS-CoV-2 and its increasing threat to human health worldwide have necessitated the development of new technological tools to combat the virus. Particular emphasis is given to the development of diagnostic methods that monitor the spread of the virus rapidly and effectively. In this study, we report the development and testing of an antibody-free biosensor, based on the immobilization of ACE2 protein on the surface of gold interdigitated electrode. When the sensor was used in laboratory conditions for targeting the virus' structural spike protein, it showed a limit of detection [LOD] of 750 pg/μL/mm2. Thereafter, the response of the sensor to swab and saliva samples from hospitalized patients was examined. The virus presence in the samples was confirmed by electrical effective capacitance measurements executed on the biosensor, and correlated with real-time PCR results. We verified that the biosensor can distinguish samples that are positive for the virus from those that are negative in a total of 7 positive and 16 negative samples. In addition, the biosensor can be used for semi-quantitative measurement, since its measurements are divided into 3 areas, the negative samples, the weakly positive and the positive samples. Reproducibility of the experiments was demonstrated with at least 3 replicates and stability was tested by keeping the sensor standby for 7 days at 4 °C before repeating the experiment. This work presents a biosensor that can be used as a fast-screening test at point of care detection of SARS-CoV-2 since it needs less than 2 min to provide results and is of simple operation.
Collapse
Affiliation(s)
- A Georgas
- National Technical University of Athens, Zografou Campus 9, Iroon Polytechniou str Zografou, 15780, Greece.
| | - E Lampas
- Konstantopoulio General Hospital, Agias Olgas 3-5, Nea Ionia, 142 33, Greece
| | - D P Houhoula
- University of West Attica, Agiou Spyridonos 28, Egaleo, 122 43, Greece
| | - A Skoufias
- National Technical University of Athens, Zografou Campus 9, Iroon Polytechniou str Zografou, 15780, Greece
| | - S Patsilinakos
- Konstantopoulio General Hospital, Agias Olgas 3-5, Nea Ionia, 142 33, Greece
| | - I Tsafaridis
- Katharsis Technologies Inc., 1200-1075, West Georgia Street, Vancouver, BC, Canada
| | - G P Patrinos
- University of Patras, University Campus, 26504, Rio, Greece
| | | | - A Ferraro
- National Technical University of Athens, Zografou Campus 9, Iroon Polytechniou str Zografou, 15780, Greece
| | - E Hristoforou
- National Technical University of Athens, Zografou Campus 9, Iroon Polytechniou str Zografou, 15780, Greece
| |
Collapse
|
15
|
Özsoylu D, Wagner T, Schöning MJ. Electrochemical Cell-based Biosensors for Biomedical Applications. Curr Top Med Chem 2022; 22:713-733. [DOI: 10.2174/1568026622666220304213617] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/31/2021] [Accepted: 01/30/2022] [Indexed: 11/22/2022]
Abstract
Abstract:
Electrochemical cell-based biosensors have been showing increasing interest within the last 15 years, with a large number of reports generally dealing with the sensors’ sensitivity, selectivity, stability, signal-to-noise ratio, spatiotemporal resolution, etc. However, only a few of them are now available as commercial products on the market. In this review, technological advances, current challenges and opportunities of electrochemical cell-based biosensors are presented. The article encompasses emerging studies, mainly focusing on the last five years (from 2016 to mid 2021), towards cell-based biological field-effect devices, cell-based impedimetric sensors and cell-based microelectrode arrays. In addition, special attention lies on recent progress in recording at the single-cellular level, including intracellular monitoring with high spatiotemporal resolution as well as integration into microfluidics for lab-on-a-chip applications. Moreover, a comprehensive discussion on challenges and future perspectives will address the future potential of electrochemical cell-based biosensors.
Collapse
Affiliation(s)
- Dua Özsoylu
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Jülich, Germany
| | - Torsten Wagner
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Jülich, Germany
- Institute of Biological Information Processing (IBI-3), Research Centre Jülich GmbH, Jülich, Germany
| | - Michael J. Schöning
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Jülich, Germany
- Institute of Biological Information Processing (IBI-3), Research Centre Jülich GmbH, Jülich, Germany
| |
Collapse
|
16
|
Nascimento ED, Fonseca WT, de Oliveira TR, de Correia CRSTB, Faça VM, de Morais BP, Silvestrini VC, Pott-Junior H, Teixeira FR, Faria RC. COVID-19 diagnosis by SARS-CoV-2 Spike protein detection in saliva using an ultrasensitive magneto-assay based on disposable electrochemical sensor. SENSORS AND ACTUATORS. B, CHEMICAL 2022; 353:131128. [PMID: 34866796 DOI: 10.1016/j.snb.2021.131148] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 11/16/2021] [Accepted: 11/18/2021] [Indexed: 05/27/2023]
Abstract
The outbreak of the COVID-19 pandemic, caused by Severe Acute Respiratory Syndrome of Coronavirus 2 (SARS-CoV-2), has fueled the search for diagnostic tests aiming at the control and reduction of the viral transmission. The main technique used for diagnosing the Coronavirus disease (COVID-19) is the reverse transcription-polymerase chain reaction (RT-PCR) technique. However, considering the high number of cases and the underlying limitations of the RT-PCR technique, especially with regard to accessibility and cost of the test, one does not need to overemphasize the need to develop new and less expensive testing techniques that can aid the early diagnosis of the disease. With that in mind, we developed an ultrasensitive magneto-assay using magnetic beads and gold nanoparticles conjugated to human angiotensin-converting enzyme 2 (ACE2) peptide (Gln24-Gln42) for the capturing and detection of SARS-CoV-2 Spike protein in human saliva. The technique applied involved the use of a disposable electrochemical device containing eight screen-printed carbon electrodes which allow the simultaneous analysis of eight samples. The magneto-assay exhibited an ultralow limit of detection of 0.35 ag mL-1 for the detection of SARS-CoV-2 Spike protein in saliva. The magneto-assay was tested in saliva samples from healthy and SARS-CoV-2-infected individuals. In terms of efficiency, the proposed technique - which presented a sensitivity of 100.0% and specificity of 93.7% for SARS-CoV-2 Spike protein-exhibited great similarity with the RT-PCR technique. The results obtained point to the application potential of this simple, low-cost magneto-assay for saliva-based point-of-care COVID-19 diagnosis.
Collapse
Affiliation(s)
- Evair D Nascimento
- Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil
| | - Wilson T Fonseca
- Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil
| | - Tássia R de Oliveira
- Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil
| | - Camila R S T B de Correia
- Department of Genetics and Evolution, Federal University of Sao Carlos-UFSCar, São Carlos, SP, 13565-905, Brazil
| | - Vitor M Faça
- Department of Biochemistry and Immunology, Ribeirão Preto Medical School, University of São Paulo-USP, Brazil
| | - Beatriz P de Morais
- Department of Biochemistry and Immunology, Ribeirão Preto Medical School, University of São Paulo-USP, Brazil
| | - Virginia C Silvestrini
- Department of Biochemistry and Immunology, Ribeirão Preto Medical School, University of São Paulo-USP, Brazil
| | - Henrique Pott-Junior
- Department of Medicine, Federal University of São Carlos-UFSCar, São Carlos, SP, 13565-905, Brazil
| | - Felipe R Teixeira
- Department of Genetics and Evolution, Federal University of Sao Carlos-UFSCar, São Carlos, SP, 13565-905, Brazil
| | - Ronaldo C Faria
- Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil
| |
Collapse
|
17
|
Nascimento ED, Fonseca WT, de Oliveira TR, de Correia CRSTB, Faça VM, de Morais BP, Silvestrini VC, Pott-Junior H, Teixeira FR, Faria RC. COVID-19 diagnosis by SARS-CoV-2 Spike protein detection in saliva using an ultrasensitive magneto-assay based on disposable electrochemical sensor. SENSORS AND ACTUATORS. B, CHEMICAL 2022; 353:131128. [PMID: 34866796 PMCID: PMC8626148 DOI: 10.1016/j.snb.2021.131128] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 11/16/2021] [Accepted: 11/18/2021] [Indexed: 05/03/2023]
Abstract
The outbreak of the COVID-19 pandemic, caused by Severe Acute Respiratory Syndrome of Coronavirus 2 (SARS-CoV-2), has fueled the search for diagnostic tests aiming at the control and reduction of the viral transmission. The main technique used for diagnosing the Coronavirus disease (COVID-19) is the reverse transcription-polymerase chain reaction (RT-PCR) technique. However, considering the high number of cases and the underlying limitations of the RT-PCR technique, especially with regard to accessibility and cost of the test, one does not need to overemphasize the need to develop new and less expensive testing techniques that can aid the early diagnosis of the disease. With that in mind, we developed an ultrasensitive magneto-assay using magnetic beads and gold nanoparticles conjugated to human angiotensin-converting enzyme 2 (ACE2) peptide (Gln24-Gln42) for the capturing and detection of SARS-CoV-2 Spike protein in human saliva. The technique applied involved the use of a disposable electrochemical device containing eight screen-printed carbon electrodes which allow the simultaneous analysis of eight samples. The magneto-assay exhibited an ultralow limit of detection of 0.35 ag mL-1 for the detection of SARS-CoV-2 Spike protein in saliva. The magneto-assay was tested in saliva samples from healthy and SARS-CoV-2-infected individuals. In terms of efficiency, the proposed technique - which presented a sensitivity of 100.0% and specificity of 93.7% for SARS-CoV-2 Spike protein-exhibited great similarity with the RT-PCR technique. The results obtained point to the application potential of this simple, low-cost magneto-assay for saliva-based point-of-care COVID-19 diagnosis.
Collapse
Affiliation(s)
- Evair D Nascimento
- Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil
| | - Wilson T Fonseca
- Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil
| | - Tássia R de Oliveira
- Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil
| | - Camila R S T B de Correia
- Department of Genetics and Evolution, Federal University of Sao Carlos-UFSCar, São Carlos, SP, 13565-905, Brazil
| | - Vitor M Faça
- Department of Biochemistry and Immunology, Ribeirão Preto Medical School, University of São Paulo-USP, Brazil
| | - Beatriz P de Morais
- Department of Biochemistry and Immunology, Ribeirão Preto Medical School, University of São Paulo-USP, Brazil
| | - Virginia C Silvestrini
- Department of Biochemistry and Immunology, Ribeirão Preto Medical School, University of São Paulo-USP, Brazil
| | - Henrique Pott-Junior
- Department of Medicine, Federal University of São Carlos-UFSCar, São Carlos, SP, 13565-905, Brazil
| | - Felipe R Teixeira
- Department of Genetics and Evolution, Federal University of Sao Carlos-UFSCar, São Carlos, SP, 13565-905, Brazil
| | - Ronaldo C Faria
- Department of Chemistry, Federal University of São Carlos-UFSCar, Rod. Washington Luís km 235, São Carlos, SP, 13565-905, Brazil
| |
Collapse
|
18
|
A review on corona virus disease 2019 (COVID-19): current progress, clinical features and bioanalytical diagnostic methods. Mikrochim Acta 2022; 189:103. [PMID: 35157153 PMCID: PMC8852957 DOI: 10.1007/s00604-022-05167-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 01/11/2022] [Indexed: 01/08/2023]
Abstract
A new epidemic of acute respiratory viral pneumonia was discovered in central China at the end of 2019. The disease was given the name coronavirus disease 2019 (COVID-19), and the virus that caused this disease was known as severe acute respiratory syndrome coronavirus (SARS-CoV-2). So far, diagnostic methods have been focused on (a) human antibody detection, (b) viral antigen detection and (c) viral gene detection, the latter using RT-PCR being the most accurate approach. In this paper, we present a summary of the COVID-19 pandemic, clinical features and epidemiology and pathogenesis. Also, we focus on the recent advances in bioanalytical diagnostic methods based on various techniques for SARS-CoV-2 sensing that have recently been published (2020–2021). Furthermore, we present the mechanisms, advantages and disadvantages of the most common biosensors for COVID-19 detection, which include optical, electrochemical and piezoelectric biosensors as well as wearable and smart nanobiosensors, immunosensors, aptasensors and genosensors.
Collapse
|
19
|
Gangula A, Kim B, Casey B, Hamill A, Regunath H, Upendran A. Point-of-Care Testing of COVID-19: Current Status, Clinical Impact, and Future Therapeutic Perspectives. SPRINGERBRIEFS IN APPLIED SCIENCES AND TECHNOLOGY 2022:1-70. [DOI: 10.1007/978-981-19-4957-9_1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
20
|
Investigation of the Morphology and Electrical Properties of Graphene Used in the Development of Biosensors for Detection of Influenza Viruses. BIOSENSORS 2021; 12:bios12010008. [PMID: 35049636 PMCID: PMC8774066 DOI: 10.3390/bios12010008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 12/12/2021] [Accepted: 12/21/2021] [Indexed: 11/17/2022]
Abstract
In this study, we discuss the mechanisms behind changes in the conductivity, low-frequency noise, and surface morphology of biosensor chips based on graphene films on SiC substrates during the main stages of the creation of biosensors for detecting influenza viruses. The formation of phenylamine groups and a change in graphene nano-arrangement during functionalization causes an increase in defectiveness and conductivity. Functionalization leads to the formation of large hexagonal honeycomb-like defects up to 500 nm, the concentration of which is affected by the number of bilayer or multilayer inclusions in graphene. The chips fabricated allowed us to detect the influenza viruses in a concentration range of 10−16 g/mL to 10−10 g/mL in PBS (phosphate buffered saline). Atomic force microscopy (AFM) and scanning electron microscopy (SEM) revealed that these defects are responsible for the inhomogeneous aggregation of antibodies and influenza viruses over the functionalized graphene surface. Non-uniform aggregation is responsible for a weak non-linear logarithmic dependence of the biosensor response versus the virus concentration in PBS. This feature of graphene nano-arrangement affects the reliability of detection of extremely low virus concentrations at the early stages of disease.
Collapse
|
21
|
Angiotensin-Converting Enzyme 2 (ACE2) As a Novel Biorecognition Element in A Cell-Based Biosensor for the Ultra-Rapid, Ultra-Sensitive Detection of the SARS-CoV-2 S1 Spike Protein Antigen. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9120341] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Antigen screening for the SARS-CoV-2 S1 spike protein is among the most promising tools for the mass monitoring of asymptomatic carriers of the virus, especially in limited resource environments. Herewith, we report on the possible use of the angiotensin-converting enzyme 2 (ACE2), the natural receptor and entry point of the virus, as a biorecognition element for the detection of the S1 antigen combined with an established bioelectric biosensor based on membrane-engineered cells. The working principle of our approach is based on the measurable change of the electric potential of membrane-engineered mammalian cells bearing ACE2 after attachment of the respective viral protein. We demonstrate that sensitive and selective detection of the S1 antigen is feasible in just three min, with a limit of detection of 20 fg/mL. In a preliminary clinical application, positive patient-derived samples were identified with a 87.9% score compared to RT-PCR. No cross-reactivity was observed against a wide range of nucleocapsid protein concentrations. The novel biosensor is embedded in a commercially ready-to-use testing platform, complete with the consumable immobilized cell–electrode interface and a portable read-out device operable through smartphone or tablet. In addition, the possible application of the system for the high throughput screening of potential pharmacological inhibitors of the ACE2 receptor-S1 RBD interaction is discussed.
Collapse
|
22
|
Bui LM, Thi Thu Phung H, Ho Thi TT, Singh V, Maurya R, Khambhati K, Wu CC, Uddin MJ, Trung DM, Chu DT. Recent findings and applications of biomedical engineering for COVID-19 diagnosis: a critical review. Bioengineered 2021; 12:8594-8613. [PMID: 34607509 PMCID: PMC8806999 DOI: 10.1080/21655979.2021.1987821] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 09/28/2021] [Indexed: 12/23/2022] Open
Abstract
COVID-19 is one of the most severe global health crises that humanity has ever faced. Researchers have restlessly focused on developing solutions for monitoring and tracing the viral culprit, SARS-CoV-2, as vital steps to break the chain of infection. Even though biomedical engineering (BME) is considered a rising field of medical sciences, it has demonstrated its pivotal role in nurturing the maturation of COVID-19 diagnostic technologies. Within a very short period of time, BME research applied to COVID-19 diagnosis has advanced with ever-increasing knowledge and inventions, especially in adapting available virus detection technologies into clinical practice and exploiting the power of interdisciplinary research to design novel diagnostic tools or improve the detection efficiency. To assist the development of BME in COVID-19 diagnosis, this review highlights the most recent diagnostic approaches and evaluates the potential of each research direction in the context of the pandemic.
Collapse
Affiliation(s)
- Le Minh Bui
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ho Chi Minh City, Vietnam
- Department of Biology, Faculty of Science and Technology, Universitas Airlangga, Surabaya, Indonesia
| | - Huong Thi Thu Phung
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ho Chi Minh City, Vietnam
| | - Thuy-Tien Ho Thi
- Center for Biomedicine and Community Health, International School, Vietnam National University, Hanoi, Vietnam
| | - Vijai Singh
- Department of Biosciences, School of Science, Indrashil University, Mehsana, Gujarat, India
| | - Rupesh Maurya
- Department of Biosciences, School of Science, Indrashil University, Mehsana, Gujarat, India
| | - Khushal Khambhati
- Department of Biosciences, School of Science, Indrashil University, Mehsana, Gujarat, India
| | - Chia-Ching Wu
- Department of Cell Biology and Anatomy, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Md Jamal Uddin
- ABEx Bio-Research Center, East Azampur, Dhaka, Bangladesh
- Graduate School of Pharmaceutical Sciences, College of Pharmacy, Ewha Womans University, Seoul, Republic of Korea
| | - Do Minh Trung
- Institute of Biomedicine and Pharmacy, Vietnam Military Medical University, Hanoi, Vietnam
| | - Dinh Toi Chu
- Center for Biomedicine and Community Health, International School, Vietnam National University, Hanoi, Vietnam
- Department of Cell Biology and Anatomy, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| |
Collapse
|
23
|
Polyelectrolyte Multilayers: An Overview on Fabrication, Properties, and Biomedical and Environmental Applications. MATERIALS 2021; 14:ma14154152. [PMID: 34361346 PMCID: PMC8348132 DOI: 10.3390/ma14154152] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Revised: 07/22/2021] [Accepted: 07/23/2021] [Indexed: 12/11/2022]
Abstract
Polyelectrolyte multilayers are versatile materials that are used in a large number of domains, including biomedical and environmental applications. The fabrication of polyelectrolyte multilayers using the layer-by-layer technique is one of the simplest methods to obtain composite functional materials. The properties of the final material can be easily tuned by changing the deposition conditions and the used building blocks. This review presents the main characteristics of polyelectrolyte multilayers, the fabrication methods currently used, and the factors influencing the layer-by-layer assembly of polyelectrolytes. The last section of this paper presents some of the most important applications of polyelectrolyte multilayers, with a special focus on biomedical and environmental applications.
Collapse
|