1
|
Raza S, Wdowiak M, Paczesny J. An Overview of Diverse Strategies To Inactivate Enterobacteriaceae-Targeting Bacteriophages. EcoSal Plus 2023; 11:eesp00192022. [PMID: 36651738 PMCID: PMC10729933 DOI: 10.1128/ecosalplus.esp-0019-2022] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 12/20/2022] [Indexed: 01/19/2023]
Abstract
Bacteriophages are viruses that infect bacteria and thus threaten industrial processes relying on the production executed by bacterial cells. Industries bear huge economic losses due to such recurring and resilient infections. Depending on the specificity of the process, there is a need for appropriate methods of bacteriophage inactivation, with an emphasis on being inexpensive and high efficiency. In this review, we summarize the reports on antiphagents, i.e., antibacteriophage agents on inactivation of bacteriophages. We focused on bacteriophages targeting the representatives of the Enterobacteriaceae family, as its representative, Escherichia coli, is most commonly used in the bio-industry. The review is divided into sections dealing with bacteriophage inactivation by physical factors, chemical factors, and nanotechnology-based solutions.
Collapse
Affiliation(s)
- Sada Raza
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland
| | - Mateusz Wdowiak
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland
| | - Jan Paczesny
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland
| |
Collapse
|
2
|
Signaling strategies of silver nanoparticles in optical and electrochemical biosensors: considering their potential for the point-of-care. Mikrochim Acta 2023; 190:91. [PMID: 36790481 PMCID: PMC9930094 DOI: 10.1007/s00604-023-05666-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 01/25/2023] [Indexed: 02/16/2023]
Abstract
Silver nanoparticles (AgNPs) have long been overshadowed by gold NPs' success in sensor and point-of-care (POC) applications. However, their unique physical, (electro)chemical, and optical properties make them excellently suited for such use, as long as their inherent higher instability toward oxidation is controlled. Recent advances in this field provide novel strategies that demonstrate that the AgNPs' inherent capabilities improve sensor performance and enable the specific detection of analytes at low concentrations. We provide an overview of these advances by focusing on the nanosized Ag (in the range of 1-100 nm) properties with emphasis on optical and electrochemical biosensors. Furthermore, we critically assess their potential for point-of-care sensors discussing advantages as well as limitations for each detection technique. We can conclude that, indeed, strategies using AgNP are ready for sensitive POC applications; however, research focusing on the simplification of assay procedures is direly needed for AgNPs to make the successful jump into actual applications.
Collapse
|
3
|
Fabrication and quantitative performance analysis of a low-cost, flexible CNT network-based DNA sensors using ink-jet printing. SENSING AND BIO-SENSING RESEARCH 2022. [DOI: 10.1016/j.sbsr.2022.100498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
4
|
Rosati G, Cisotto G, Sili D, Compagnucci L, De Giorgi C, Pavone EF, Paccagnella A, Betti V. Inkjet-printed fully customizable and low-cost electrodes matrix for gesture recognition. Sci Rep 2021; 11:14938. [PMID: 34294822 PMCID: PMC8298403 DOI: 10.1038/s41598-021-94526-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Accepted: 07/05/2021] [Indexed: 11/11/2022] Open
Abstract
The use of surface electromyography (sEMG) is rapidly spreading, from robotic prostheses and muscle computer interfaces to rehabilitation devices controlled by residual muscular activities. In this context, sEMG-based gesture recognition plays an enabling role in controlling prosthetics and devices in real-life settings. Our work aimed at developing a low-cost, print-and-play platform to acquire and analyse sEMG signals that can be arranged in a fully customized way, depending on the application and the users' needs. We produced 8-channel sEMG matrices to measure the muscular activity of the forearm using innovative nanoparticle-based inks to print the sensors embedded into each matrix using a commercial inkjet printer. Then, we acquired the multi-channel sEMG data from 12 participants while repeatedly performing twelve standard finger movements (six extensions and six flexions). Our results showed that inkjet printing-based sEMG signals ensured significant similarity values across repetitions in every participant, a large enough difference between movements (dissimilarity index above 0.2), and an overall classification accuracy of 93-95% for flexion and extension, respectively.
Collapse
Affiliation(s)
- Giulio Rosati
- Department of Information Engineering, University of Padova, via G. Gradenigo 6b, 35131, Padova, Italy.
| | - Giulia Cisotto
- Department of Information Engineering, University of Padova, via G. Gradenigo 6b, 35131, Padova, Italy
- NCNP, National Centre of Neurology and Psychiatry, Tokyo, Japan
- CNIT, the National, Inter-University Consortium for Telecommunications, Rome, Italy
| | - Daniele Sili
- Department of Psychology, University of Rome "La Sapienza", Piazzale Aldo Moro 5, 00185, Rome, Italy
- IRCCS Fondazione Santa Lucia, Via Ardeatina, 306/354, 00179, Rome, Italy
| | - Luca Compagnucci
- Department of Psychology, University of Rome "La Sapienza", Piazzale Aldo Moro 5, 00185, Rome, Italy
- IRCCS Fondazione Santa Lucia, Via Ardeatina, 306/354, 00179, Rome, Italy
| | - Chiara De Giorgi
- Department of Psychology, University of Rome "La Sapienza", Piazzale Aldo Moro 5, 00185, Rome, Italy
- IRCCS Fondazione Santa Lucia, Via Ardeatina, 306/354, 00179, Rome, Italy
| | | | - Alessandro Paccagnella
- Department of Information Engineering, University of Padova, via G. Gradenigo 6b, 35131, Padova, Italy
| | - Viviana Betti
- Department of Psychology, University of Rome "La Sapienza", Piazzale Aldo Moro 5, 00185, Rome, Italy
- IRCCS Fondazione Santa Lucia, Via Ardeatina, 306/354, 00179, Rome, Italy
| |
Collapse
|
5
|
Fuentes-Chust C, Parolo C, Rosati G, Rivas L, Perez-Toralla K, Simon S, de Lecuona I, Junot C, Trebicka J, Merkoçi A. The Microbiome Meets Nanotechnology: Opportunities and Challenges in Developing New Diagnostic Devices. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2006104. [PMID: 33719117 DOI: 10.1002/adma.202006104] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 11/26/2020] [Indexed: 05/15/2023]
Abstract
Monitoring of the human microbiome is an emerging area of diagnostics for personalized medicine. Here, the potential of different nanomaterials and nanobiosensing technologies is reviewed for the development of novel diagnostic devices for the detection and measurement of microbiome-related biomarkers. Moreover, the current and future landscape of microbiome-based diagnostics is defined by exploring the advantages and disadvantages of current nanotechnology-based approaches, especially in the context of developing point-of-care (PoC) devices that would meet the international guidelines known as REASSURED (Real-time connectivity; Ease of specimen collection; Affordability; Sensitivity; Specificity; User-friendliness; Rapid & robust operation; Equipment-free; and Deliverability). Finally, the strategies of the latest international scientific consortia working in this field are analyzed, the current microbiome diagnostics market are reported and the principal ethical, legal, and societal issues related to microbiome R&D and innovation are discussed.
Collapse
Affiliation(s)
- Celia Fuentes-Chust
- Nanobioelectronics and Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), UAB Campus, Bellaterra, Barcelona, 08193, Spain
| | - Claudio Parolo
- Nanobioelectronics and Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), UAB Campus, Bellaterra, Barcelona, 08193, Spain
| | - Giulio Rosati
- Nanobioelectronics and Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), UAB Campus, Bellaterra, Barcelona, 08193, Spain
| | - Lourdes Rivas
- Nanobioelectronics and Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), UAB Campus, Bellaterra, Barcelona, 08193, Spain
| | - Karla Perez-Toralla
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), SPI, Gif-sur-Yvette cedex, 91191, France
| | - Stéphanie Simon
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), SPI, Gif-sur-Yvette cedex, 91191, France
| | - Itziar de Lecuona
- Bioethics and Law Observatory -UNESCO Chair in Bioethics-Department of Medicine, University of Barcelona, Barcelona, 08007, Spain
| | - Christophe Junot
- Université Paris-Saclay, CEA, INRAE, Département Médicaments et Technologies pour la Santé (MTS), SPI, Gif-sur-Yvette cedex, 91191, France
| | - Jonel Trebicka
- Department of Internal Medicine I, Goethe University Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany
- European Foundation for the Study of Chronic Liver Failure, Travesera de Gracia 11, Barcelona, 08021, Spain
| | - Arben Merkoçi
- Nanobioelectronics and Biosensors Group, Institut Català de Nanociència i Nanotecnologia (ICN2), UAB Campus, Bellaterra, Barcelona, 08193, Spain
- ICREA, Institució Catalana de Recerca i Estudis Avançats, Pg. Lluís Companys 23, Barcelona, 08010, Spain
| |
Collapse
|
6
|
Monitoring microbial growth on a microfluidic lab-on-chip with electrochemical impedance spectroscopic technique. Biomed Microdevices 2021; 23:26. [PMID: 33885989 DOI: 10.1007/s10544-021-00564-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/12/2021] [Indexed: 12/17/2022]
Abstract
A continuous rise in the wastes from industrial effluents, bio-waste, and pharmaceuticals has deteriorated surface water and drinking water sources. Standard laboratory tests of total coliform are time-consuming and logistically inefficient for field data generation. Better and portable sensing technologies are needed. This paper reports an electrical impedance spectroscopic technique incorporated in a micro-fluidic chip with interdigitated microelectrodes to monitor the growth of microbial cells. Lag, log, and stationary phases of Escherichia coli cell growth with an integrated electrode are successfully detected, for samples of reverse osmosis water, standard treated tap water, and recycled water respectively. The results indicate that reverse osmosis water has a higher probability of contamination with bacterial pathogens compared to the other two types of water samples when subjected to the same amount of added nutrients. The statistical analysis shows a possible single detection range with higher-order regression, and repeat use of a single chip with the electrode was found to be within an acceptable limit. The interdigitated electrodes exposed to in-situ cell growth conditions and repeated electrical measurements have shown a promise for possible periodic or continuous monitoring. The paper further identifies several complimentary analysis methodologies that are robust towards phase noise in the measured impedance and are suited particularly for early-stage detection of bacterial contamination. The cell adhesion tendencies over the microelectrode due to the electric field need to be further analyzed.
Collapse
|
7
|
Interdigitated and Wave-Shaped Electrode-Based Capacitance Sensor for Monitoring Antibiotic Effects. SENSORS 2020; 20:s20185237. [PMID: 32937982 PMCID: PMC7570453 DOI: 10.3390/s20185237] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 09/11/2020] [Accepted: 09/11/2020] [Indexed: 12/26/2022]
Abstract
Label-free and real-time monitoring of the bacterial viability is essential for the accurate and sensitive characterization of the antibiotic effects. In the present study, we investigated the feasibility of the interdigitated and wave-shaped electrode (IWE) for monitoring the effect of tetracycline or kanamycin on Staphylococcus aureus (S. aureus) and methicillin-resistant S.aureus (MRSA). The electrical impedance spectra of the IWE immersed in the culture media for bacterial growth were characterized in a frequency range of 10 Hz to 1 kHz. The capacitance index (CI) (capacitance change relevant with the bacterial viability) was used to monitor the antibiotic effects on the S. aureus and MRSA in comparison to the traditional methods (disk diffusion test and optical density (OD) measurement). The experimental results showed that the percentage of change in CI (PCI) for the antibiotic effect on MRSA was increased by 51.58% and 57.83% in kanamycin and control, respectively. In contrast, the PCI value decreased by 0.25% for tetracycline, decreased by 52.63% and 37.66% in the cases of tetracycline and kanamycin-treated S. aureus, and increased 2.79% in the control, respectively. This study demonstrated the feasibility of the IWE-based capacitance sensor for the label-free and real-time monitoring of the antibiotic effects on S. aureus and MRSA.
Collapse
|
8
|
Chai C, Oh SW. Electrochemical impedimetric biosensors for food safety. Food Sci Biotechnol 2020; 29:879-887. [PMID: 32582450 PMCID: PMC7297935 DOI: 10.1007/s10068-020-00776-w] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 05/12/2020] [Accepted: 05/17/2020] [Indexed: 12/20/2022] Open
Abstract
Electrochemical impedimetric biosensors (EIBs) have a simple structure and can be used to rapidly and sensitively detect and measure hazards in food. EIBs detect and measure target molecules by transducing biochemical reactions on their surface to electrical signal outputs responding to a sinusoidal electrical signal input. Due to their structural simplicity and analytical sensitivity, EIBs are regarded as the most potent method of food hazard monitoring that can be implemented in the food supply chain. This paper discusses the theoretical background, structure, and construction of EIB and its applications in food safety.
Collapse
Affiliation(s)
- Changhoon Chai
- Department of Applied Animal Science, Kangwon National University, Chuncheon, 24341 Republic of Korea
| | - Se-Wook Oh
- Department of Food and Nutrition, Kookmin University, Seoul, 02707 Republic of Korea
| |
Collapse
|
9
|
Arreola J, Keusgen M, Wagner T, Schöning MJ. Combined calorimetric gas- and spore-based biosensor array for online monitoring and sterility assurance of gaseous hydrogen peroxide in aseptic filling machines. Biosens Bioelectron 2019; 143:111628. [PMID: 31476599 DOI: 10.1016/j.bios.2019.111628] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 08/09/2019] [Accepted: 08/21/2019] [Indexed: 10/26/2022]
Abstract
A combined calorimetric gas- and spore-based biosensor array is presented in this work to monitor and evaluate the sterilization efficacy of gaseous hydrogen peroxide in aseptic filling machines. H2O2 has been successfully measured under industrial conditions. Furthermore, the effect of H2O2 on three different spore strains , namely Bacillus atrophaeus, Bacillus subtilis and Geobacillus stearothermophilus, has been investigated by means of SEM, AFM and impedimetric measurements. In addition, the sterilization efficacy of a spore-based biosensor and the functioning principle are addressed and discussed: the sensor array is convenient to be used in aseptic food industry to guarantee sterile packages.
Collapse
Affiliation(s)
- Julio Arreola
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428, Jülich, Germany; Institute of Pharmaceutical Chemistry, Philipps-University Marburg, Marbacher Weg 6-10, 35032 Marburg, Germany
| | - Michael Keusgen
- Institute of Pharmaceutical Chemistry, Philipps-University Marburg, Marbacher Weg 6-10, 35032 Marburg, Germany
| | - Torsten Wagner
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428, Jülich, Germany; Institute of Complex Systems 8 (ICS-8), Research Centre Jülich GmbH, 52425, Jülich, Germany
| | - Michael J Schöning
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428, Jülich, Germany; Institute of Complex Systems 8 (ICS-8), Research Centre Jülich GmbH, 52425, Jülich, Germany.
| |
Collapse
|
10
|
Abstract
An increasing number of fields in everyday life require the development and application of ever more modern and efficient chemical sensors and biosensors, namely to be integrated in intelligent control system networks [...]
Collapse
|