1
|
Fort A, Landi E, Moretti R, Mugnaini M, Liguori C, Paciello V, Dello Iacono S. Influence of Front-End Electronics on Metrological Performance of QCM Systems. SENSORS (BASEL, SWITZERLAND) 2024; 24:3401. [PMID: 38894192 PMCID: PMC11174881 DOI: 10.3390/s24113401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 05/10/2024] [Accepted: 05/23/2024] [Indexed: 06/21/2024]
Abstract
Quartz Crystal Microbalances (QCMs) are versatile sensors employed in various fields, from environmental monitoring to biomedical applications, owing mainly to their very high sensitivity. However, the assessment of their metrological performance, including the impact of conditioning circuits, digital processing algorithms, and working conditions, is a complex and novel area of study. The purpose of this work is to investigate and understand the measurement errors associated with different QCM measurement techniques, specifically focusing on the influence of conditioning electronic circuits. Through a tailored and novel experimental setup, two measurement architectures-a Quartz Crystal Microbalance with dissipation monitoring (QCM-D) system and an oscillator-based QCM-R system-were compared under the same mechanical load conditions. Through rigorous experimentation and signal processing techniques, the study elucidated the complexities of accurately assessing QCM parameters, especially in liquid environments and under large mechanical loads. The comparison between the two different techniques allows for highlighting the critical aspects of the measurement techniques. The experimental results were discussed and interpreted based on models allowing for a deep understanding of the measurement problems encountered with QCM-based measurement systems. The performance of the different techniques was derived, showing that while the QCM-D technique exhibited higher accuracy, the QCM-R technique offered greater precision with a simpler design. This research advances our understanding of QCM-based measurements, providing insights for designing robust measurement systems adaptable to diverse conditions, thus enhancing their effectiveness in various applications.
Collapse
Affiliation(s)
- Ada Fort
- Department of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy; (E.L.); (R.M.); (M.M.)
| | - Elia Landi
- Department of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy; (E.L.); (R.M.); (M.M.)
| | - Riccardo Moretti
- Department of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy; (E.L.); (R.M.); (M.M.)
| | - Marco Mugnaini
- Department of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy; (E.L.); (R.M.); (M.M.)
| | - Consolatina Liguori
- Department of Industrial Engineering, University of Salerno, 84084 Salerno, Italy; (C.L.); (V.P.)
| | - Vincenzo Paciello
- Department of Industrial Engineering, University of Salerno, 84084 Salerno, Italy; (C.L.); (V.P.)
| | | |
Collapse
|
2
|
Alfieri G, Modesti M, Riggi R, Bellincontro A. Recent Advances and Future Perspectives in the E-Nose Technologies Addressed to the Wine Industry. SENSORS (BASEL, SWITZERLAND) 2024; 24:2293. [PMID: 38610504 PMCID: PMC11014050 DOI: 10.3390/s24072293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 03/26/2024] [Accepted: 04/01/2024] [Indexed: 04/14/2024]
Abstract
Electronic nose devices stand out as pioneering innovations in contemporary technological research, addressing the arduous challenge of replicating the complex sense of smell found in humans. Currently, sensor instruments find application in a variety of fields, including environmental, (bio)medical, food, pharmaceutical, and materials production. Particularly the latter, has seen a significant increase in the adoption of technological tools to assess food quality, gradually supplanting human panelists and thus reshaping the entire quality control paradigm in the sector. This process is happening even more rapidly in the world of wine, where olfactory sensory analysis has always played a central role in attributing certain qualities to a wine. In this review, conducted using sources such as PubMed, Science Direct, and Web of Science, we examined papers published between January 2015 and January 2024. The aim was to explore prevailing trends in the use of human panels and sensory tools (such as the E-nose) in the wine industry. The focus was on the evaluation of wine quality attributes by paying specific attention to geographical origin, sensory defects, and monitoring of production trends. Analyzed results show that the application of E-nose-type sensors performs satisfactorily in that trajectory. Nevertheless, the integration of this type of analysis with more classical methods, such as the trained sensory panel test and with the application of destructive instrument volatile compound (VOC) detection (e.g., gas chromatography), still seems necessary to better explore and investigate the aromatic characteristics of wines.
Collapse
Affiliation(s)
| | | | | | - Andrea Bellincontro
- Department for Innovation in Biological, Agro-Food and Forest Systems, University of Tuscia, Via S. Camillo de Lellis, 01100 Viterbo, Italy; (G.A.); (M.M.); (R.R.)
| |
Collapse
|
3
|
Skládal P. Piezoelectric biosensors: shedding light on principles and applications. Mikrochim Acta 2024; 191:184. [PMID: 38451295 PMCID: PMC10920441 DOI: 10.1007/s00604-024-06257-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 02/19/2024] [Indexed: 03/08/2024]
Abstract
The three decades of experience with piezoelectric devices applied in the field of bioanalytical chemistry are shared. After introduction to principles and suitable measuring approaches, active and passive methods based on oscillators and impedance analysis, respectively, the focus is directed towards biosensing approaches. Immunosensing examples are provided, followed by other affinity sensing approaches based on hybridization of nucleic acids, aptamers, monitoring of enzyme activities, and detection of pathogenic microbes. The combination of piezosensors with cell lines and testing of drugs is highlighted, including mechanically active cells. The combination of piezosensors with other measuring techniques providing original hybrid devices is briefly discussed.
Collapse
Affiliation(s)
- Petr Skládal
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 62500, Brno, Czech Republic.
| |
Collapse
|
4
|
Burda I. Effect of Load on Quartz Crystal Microbalance Sensor Response Addressed Using Fractional Order Calculus. SENSORS (BASEL, SWITZERLAND) 2023; 23:6768. [PMID: 37571551 PMCID: PMC10422237 DOI: 10.3390/s23156768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 07/24/2023] [Accepted: 07/27/2023] [Indexed: 08/13/2023]
Abstract
To accurately model the effect of the load caused by a liquid medium as a function of its viscosity, the fractional order Butterworth-Van Dyke (BVD) model of the QCM sensor is proposed in this study. A comprehensive understanding of the fractional order BVD model followed by a simulation of situations commonly encountered in experimental investigations underpins the new QCM sensor approach. The Levenberg-Marquardt (LM) algorithm is used in two fitting steps to extract all parameters of the fractional order BVD model. The integer-order electrical parameters were determined in the first step and the fractional order parameters were extracted in the second step. A parametric investigation was performed in air, water, and glycerol-water solutions in ten-percent steps for the fractional order BVD model. This indicated a change in the behavior of the QCM sensor when it swapped from air to water, modeled by the fractional order BVD model, followed by a specific dependence with increasing viscosity of the glycerol-water solution. The effect of the liquid medium on the reactive motional circuit elements of the BVD model in terms of fractional order calculus (FOC) was experimentally demonstrated. The experimental results demonstrated the value of the fractional order BVD model for a better understanding of the interactions occurring at the QCM sensor surface.
Collapse
Affiliation(s)
- Ioan Burda
- Physics Department, Babes-Bolyai University, 400084 Cluj-Napoca, Romania
| |
Collapse
|
5
|
Senturk F, Kocum IC, Seyitoglu MI, Aksan ES. A quartz crystal microbalance (QCM)-based easy setup device for real-time mass change detection under high-power RF plasma. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:064704. [PMID: 37862482 DOI: 10.1063/5.0142016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 05/23/2023] [Indexed: 10/22/2023]
Abstract
Sensing technologies serve a crucial role in monitoring and testing surface properties in biosensors, thin films, and many other industries. Plasma treatments are routinely used in most of these technologies to modify the surfaces of materials. However, due to the high radio frequency (RF) noise in plasma processes, real-time surface tracking is still rather difficult. In this study, we aim to construct an easy-to-set up mass change detection system capable of operating under RF plasma conditions. For this purpose, we have presented a novel technique that utilizes the quartz crystal microbalance sensor to detect mass changes in different plasma environments. The constructed device was then tested under 13.56 MHz, 100 W plasma atmosphere. The results showed that the resonance frequency of a crystal was successfully measured with 1.0 Hz resolution under the impact of plasma-induced high power of RF noise. Moreover, as a preliminary study, we used ethylenediamine (EDA) to track changes in resonance frequency under plasma conditions and observed noise-free signals in frequency-voltage curves. Furthermore, the system's sensitivity was found to be 3.8 ng/Hz, with a test molecule (EDA) deposition of about 380 ng in the RF plasma atmosphere. Overall, this study focused on creating a relatively new approach for detecting the real-time mass change in a strong RF environment, which we believe could be an improved and easy-to-set up technique for plasma-based processes such as surface coating, etching, and activation.
Collapse
Affiliation(s)
- Fatih Senturk
- Department of Biophysics, Faculty of Medicine, Duzce University, Duzce, Türkiye
| | | | | | - Eda Sevval Aksan
- Department of Biomedical Engineering, Baskent University, Ankara, Türkiye
| |
Collapse
|
6
|
Alanazi N, Almutairi M, Alodhayb AN. A Review of Quartz Crystal Microbalance for Chemical and Biological Sensing Applications. SENSING AND IMAGING 2023; 24:10. [PMID: 36908332 PMCID: PMC9985094 DOI: 10.1007/s11220-023-00413-w] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Revised: 01/21/2023] [Accepted: 01/26/2023] [Indexed: 06/18/2023]
Abstract
Humans are fundamentally interested in monitoring and understanding interactions that occur in and around our bodies. Biological interactions within the body determine our physical condition and can be used to improve medical treatments and develop new drugs. Daily life involves contact with numerous chemicals, ranging from household elements, naturally occurring scents from common plants and animals, and industrial agents. Many chemicals cause adverse health and environmental effects and require regulation to prevent pollution. Chemical detection is critically important for food and environmental quality control efforts, medical diagnostics, and detection of explosives. Thus, sensitive devices are needed for detecting and discriminating chemical and biological samples. Compared to other sensing devices, the Quartz Crystal Microbalance (QCM) is well-established and has been considered and sufficiently sensitive for detecting molecules, chemicals, polymers, and biological assemblies. Due to its simplicity and low cost, the QCM sensor has potential applications in analytical chemistry, surface chemistry, biochemistry, environmental science, and other disciplines. QCM detection measures resonate frequency changes generated by the quartz crystal sensor when covered with a thin film or liquid. The quartz crystal is sandwiched between two metal (typically gold) electrodes. Functionalizing the electrode's surface further enhances frequency change detection through to interactions between the sensor and the targeted material. These sensors are sensitive to high frequencies and can recognize ultrasmall masses. This review will cover advancements in QCM sensor technologies, highlighting in-sensor and real-time analysis. QCM-based sensor function is dictated by the coating material. We present various high-sensitivity coating techniques that use this novel sensor design. Then, we briefly review available measurement parameters and technological interventions that will inform future QCM research. Lastly, we examine QCM's theory and application to enhance our understanding of relevant electrical components and concepts.
Collapse
Affiliation(s)
- Nadyah Alanazi
- Department of Physics and Astronomy, College of Science, King Saud University, Riyadh, 11451 Saudi Arabia
| | - Maram Almutairi
- Department of Physics and Astronomy, College of Science, King Saud University, Riyadh, 11451 Saudi Arabia
| | - Abdullah N. Alodhayb
- Department of Physics and Astronomy, College of Science, King Saud University, Riyadh, 11451 Saudi Arabia
- King Abdullah Institute for Nanotechnology, King Saud University, Riyadh, 11451 Saudi Arabia
| |
Collapse
|
7
|
Al-Gethami W, Al-Qasmi N, Ismail SH, Sadek AH. QCM-Based MgFe 2O 4@CaAlg Nanocomposite as a Fast Response Nanosensor for Real-Time Detection of Methylene Blue Dye. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 13:97. [PMID: 36616006 PMCID: PMC9824339 DOI: 10.3390/nano13010097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Revised: 12/17/2022] [Accepted: 12/22/2022] [Indexed: 06/17/2023]
Abstract
Methylene blue (MB) dye is a common colorant used in numerous industries, particularly the textile industry. When methylene blue is discharged into water bodies without being properly treated, it may seriously damage aquatic and human life. As a result, a variety of methods have been established to remove dyes from aqueous systems. Thanks to their distinguishing features e.g., rapid responsiveness, cost-effectiveness, potential selectivity, portability, and simplicity, the electrochemical methods provided promising techniques. Considering these aspects, a novel quartz crystal microbalance nanosensors based on green synthesized magnesium ferrite nanoparticles (QCM-Based MgFe2O4 NPs) and magnesium ferrite nanoparticles coated alginate hydrogel nanocomposite (QCM-Based MgFe2O4@CaAlg NCs) were designed for real-time detection of high concentrations of MB dye in the aqueous streams at different temperatures. The characterization results of MgFe2O4 NPs and MgFe2O4@CaAlg NCs showed that the MgFe2O4 NPs have synthesized in good crystallinity, spherical shape, and successfully coated by the alginate hydrogel. The performance of the designed QCM-Based MgFe2O4 NPs and MgFe2O4@CaAlg NCs nanosensors were examined by the QCM technique, where the developed nanosensors showed great potential for dealing with continuous feed, very small volumes, high concentrations of MB, and providing an instantaneous response. In addition, the alginate coating offered more significant attributes to MgFe2O4 NPs and enhanced the sensor work toward MB monitoring. The sensitivity of designed nanosensors was evaluated at different MB concentrations (100 mg/L, 400 mg/L, and 800 mg/L), and temperatures (25 °C, 35 °C, and 45 °C). Where a real-time detection of 400 mg/L MB was achieved using the developed sensing platforms at different temperatures within an effective time of about 5 min. The results revealed that increasing the temperature from 25 °C to 45 °C has improved the detection of MB using the MgFe2O4@CaAlg NCs nanosensor and the MgFe2O4@CaAlg NCs nanosensor exhibited high sensitivity for different MB concentrations with more efficiency than the MgFe2O4 NPs nanosensor.
Collapse
Affiliation(s)
- Wafa Al-Gethami
- Chemistry Department, Faculty of Science, Taif University, Al-Hawiah, Taif City P.O. Box 11099, Saudi Arabia
| | - Noha Al-Qasmi
- Chemistry Department, Faculty of Science, Taif University, Al-Hawiah, Taif City P.O. Box 11099, Saudi Arabia
| | - Sameh H. Ismail
- Nano Engineering-Xnem Program, Faculty of Nanotechnology for Postgraduate Studies, Sheikh Zayed Campus, Cairo University, 6th October City, Giza 12588, Egypt
| | - Ahmed H. Sadek
- Nano Engineering-Xnem Program, Faculty of Nanotechnology for Postgraduate Studies, Sheikh Zayed Campus, Cairo University, 6th October City, Giza 12588, Egypt
- Environmental Engineering Program, Zewail City of Science, Technology and Innovation, 6th October City, Giza 12578, Egypt
| |
Collapse
|
8
|
Santjojo DJDH. The Impedance Analysis of a Viscoelastic Petalous Structured Stearic Acid Functional Layer Deposited on a QCM. SENSORS (BASEL, SWITZERLAND) 2022; 22:7504. [PMID: 36236603 PMCID: PMC9570775 DOI: 10.3390/s22197504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/21/2022] [Accepted: 09/29/2022] [Indexed: 06/16/2023]
Abstract
A functional layer is crucial in a QCM sensor, to immobilize target molecules. The microstructure of the layer determines the sensitivity of the sensor. On the other hand, the microstructure also affects the loading of the sensor. In this study, impedance analysis was used to investigate the relationship between the microstructure and the viscoelastic properties of a petalous stearic acid (SA) functional layer. The SA layer was deposited using a vacuum thermal evaporation technique. Different petalous pillar structures in the elastic layer were generated by varying the deposition time. Analysis showed that the growth of the embedded pillar structures dramatically reduced the conductance and increased the bandwidth. The energy dissipation during the vibration could be related to the interaction between the pillars and the elastic matrix.
Collapse
Affiliation(s)
- Dionysius J D H Santjojo
- Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Brawijaya, Malang 65145, Indonesia
| |
Collapse
|
9
|
Naranda J, Bračič M, Vogrin M, Maver U, Trojner T. Practical Use of Quartz Crystal Microbalance Monitoring in Cartilage Tissue Engineering. J Funct Biomater 2022; 13:jfb13040159. [PMID: 36278628 PMCID: PMC9590066 DOI: 10.3390/jfb13040159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 09/14/2022] [Accepted: 09/17/2022] [Indexed: 11/29/2022] Open
Abstract
Quartz crystal microbalance (QCM) is a real-time, nanogram-accurate technique for analyzing various processes on biomaterial surfaces. QCM has proven to be an excellent tool in tissue engineering as it can monitor key parameters in developing cellular scaffolds. This review focuses on the use of QCM in the tissue engineering of cartilage. It begins with a brief discussion of biomaterials and the current state of the art in scaffold development for cartilage tissue engineering, followed by a summary of the potential uses of QCM in cartilage tissue engineering. This includes monitoring interactions with extracellular matrix components, adsorption of proteins onto biomaterials, and biomaterial–cell interactions. In the last part of the review, the material selection problem in tissue engineering is highlighted, emphasizing the importance of surface nanotopography, the role of nanofilms, and utilization of QCM as a “screening” tool to improve the material selection process. A step-by-step process for scaffold design is proposed, as well as the fabrication of thin nanofilms in a layer-by-layer manner using QCM. Finally, future trends of QCM application as a “screening” method for 3D printing of cellular scaffolds are envisioned.
Collapse
Affiliation(s)
- Jakob Naranda
- Department of Orthopaedics, University Medical Centre Maribor, SI-2000 Maribor, Slovenia
- Department of Orthopaedics, Faculty of Medicine, University of Maribor, SI-2000 Maribor, Slovenia
- Correspondence: (J.N.); (M.B.); Tel.: +386-2-321-1541 (J.N.); +386-2-220-7929 (M.B.)
| | - Matej Bračič
- Laboratory for Characterisation and Processing of Polymers (LCPP), Faculty of Mechanical Engineering, University of Maribor, SI-2000 Maribor, Slovenia
- Correspondence: (J.N.); (M.B.); Tel.: +386-2-321-1541 (J.N.); +386-2-220-7929 (M.B.)
| | - Matjaž Vogrin
- Department of Orthopaedics, University Medical Centre Maribor, SI-2000 Maribor, Slovenia
- Department of Orthopaedics, Faculty of Medicine, University of Maribor, SI-2000 Maribor, Slovenia
| | - Uroš Maver
- Institute of Biomedical Sciences, Faculty of Medicine, University of Maribor, SI-2000 Maribor, Slovenia
- Department of Pharmacology, Faculty of Medicine, University of Maribor, SI-2000 Maribor, Slovenia
| | - Teodor Trojner
- Department of Orthopaedics, University Medical Centre Maribor, SI-2000 Maribor, Slovenia
| |
Collapse
|
10
|
Länge K. Bulk and Surface Acoustic Wave Biosensors for Milk Analysis. BIOSENSORS 2022; 12:bios12080602. [PMID: 36005001 PMCID: PMC9405821 DOI: 10.3390/bios12080602] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 07/29/2022] [Accepted: 07/29/2022] [Indexed: 05/06/2023]
Abstract
Milk and dairy products are common foods and, therefore, are subject to regular controls. Such controls cover both the identification and quantification of specific components and the determination of physical parameters. Components include the usual milk ingredients, mainly carbohydrates, proteins, and fat, and any impurities that may be present. The latter range from small molecules, such as drug residues, to large molecules, e.g., protein-based toxins, to pathogenic microorganisms. Physical parameters of interest include viscosity as an indicator of milk gelation. Bulk and surface acoustic wave sensors, such as quartz crystal microbalance (QCM) and surface acoustic wave (SAW) devices, can principally be used for both types of analysis, with the actual application mainly depending on the device coating and the test format. This review summarizes the achievements of acoustic sensor devices used for milk analysis applications, including the determination of physical liquid parameters and the detection of low- and high-molecular-weight analytes and microorganisms. It is shown how the various requirements resulting from the respective analytes and the complex sample matrix are addressed, and to what extent the analytical demands, e.g., with regard to legal limits, are met.
Collapse
Affiliation(s)
- Kerstin Länge
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| |
Collapse
|
11
|
Use of Cysteamine and Glutaraldehyde Chemicals for Robust Functionalization of Substrates with Protein Biomarkers—An Overview on the Construction of Biosensors with Different Transductions. BIOSENSORS 2022; 12:bios12080581. [PMID: 36004978 PMCID: PMC9406156 DOI: 10.3390/bios12080581] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 07/21/2022] [Accepted: 07/27/2022] [Indexed: 11/17/2022]
Abstract
Currently, several biosensors are reported to confirm the absence/presence of an abnormal level of specific human biomarkers in research laboratories. Unfortunately, public marketing and/or pharmacy accessibility are not yet possible for many bodily fluid biomarkers. The questions are numerous, starting from the preparation of the substrates, the wet/dry form of recognizing the (bio)ligands, the exposure time, and the choice of the running buffers. In this context, for the first time, the present overview summarizes the pre-functionalization of standard and nanostructured solid/flexible supports with cysteamine (Cys) and glutaraldehyde (GA) chemicals for robust protein immobilization and detection of biomarkers in body fluids (serum, saliva, and urine) using three transductions: piezoelectrical, electrochemical, and optical, respectively. Thus, the reader can easily access and compare step-by-step conjugate protocols published over the past 10 years. In conclusion, Cys/GA chemistry seems widely used for electrochemical sensing applications with different types of recorded signals, either current, potential, or impedance. On the other hand, piezoelectric detection via quartz crystal microbalance (QCM) and optical detection by surface plasmon resonance (LSPR)/surface-enhanced Raman spectroscopy (SERS) are ultrasensitive platforms and very good candidates for the miniaturization of medical devices in the near future.
Collapse
|
12
|
Materials for Chemical Sensing: A Comprehensive Review on the Recent Advances and Outlook Using Ionic Liquids, Metal–Organic Frameworks (MOFs), and MOF-Based Composites. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10080290] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The ability to measure and monitor the concentration of specific chemical and/or gaseous species (i.e., “analytes”) is the main requirement in many fields, including industrial processes, medical applications, and workplace safety management. As a consequence, several kinds of sensors have been developed in the modern era according to some practical guidelines that regard the characteristics of the active (sensing) materials on which the sensor devices are based. These characteristics include the cost-effectiveness of the materials’ manufacturing, the sensitivity to analytes, the material stability, and the possibility of exploiting them for low-cost and portable devices. Consequently, many gas sensors employ well-defined transduction methods, the most popular being the oxidation (or reduction) of the analyte in an electrochemical reactor, optical techniques, and chemiresistive responses to gas adsorption. In recent years, many of the efforts devoted to improving these methods have been directed towards the use of certain classes of specific materials. In particular, ionic liquids have been employed as electrolytes of exceptional properties for the preparation of amperometric gas sensors, while metal–organic frameworks (MOFs) are used as highly porous and reactive materials which can be employed, in pure form or as a component of MOF-based functional composites, as active materials of chemiresistive or optical sensors. Here, we report on the most recent developments relative to the use of these classes of materials in chemical sensing. We discuss the main features of these materials and the reasons why they are considered interesting in the field of chemical sensors. Subsequently, we review some of the technological and scientific results published in the span of the last six years that we consider among the most interesting and useful ones for expanding the awareness on future trends in chemical sensing. Finally, we discuss the prospects for the use of these materials and the factors involved in their possible use for new generations of sensor devices.
Collapse
|
13
|
Detection of N-hexanoyl-L-homoserine lactone via MIP-based QCM sensor: preparation and characterization. Polym Bull (Berl) 2022. [DOI: 10.1007/s00289-022-04377-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
14
|
A Study on Regenerative Quartz Crystal Microbalance. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10070262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The quartz crystal microbalance with dissipation (QCM-D) represented a substantial breakthrough in the use of the QCM sensor in diverse applications ranging from environmental monitoring to biomedical diagnostics. To obtain the required selectivity and sensitivity of a volatile organic compounds (VOC) sensor, it is necessary to coat the QCM sensor with a sensing film. As the QCM sensor is coated with the sensing film, an increase in the dissipation factor occurs, resulting in a shorter and shorter ring-down time. This decrease in ring-down time makes it difficult to implement the QCM-D method in an economical and portable configuration from the perspective of large-scale applications. To compensate for this effect, a regenerative method is proposed by which the damping effect produced by the sensing film is eliminated. In this sense, a regenerative circuit as an extension to a virtual instrument is proposed to validate the experimental method. The simulation of the ring-down time for the QCM sensor in the air considering the effect of the added sensing film, followed by the basic theoretical concepts of the regenerative method and the experimental results obtained, are analyzed in detail in this paper.
Collapse
|
15
|
Li YR, Lee KL, Chen KM, Lu YC, Wu PC, Chen SH, Lee JH, Wei PK. Direct detection of virus-like particles using color images of plasmonic nanostructures. OPTICS EXPRESS 2022; 30:22233-22246. [PMID: 36224926 DOI: 10.1364/oe.461428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Accepted: 05/19/2022] [Indexed: 06/16/2023]
Abstract
We propose a measurement method for sensitive and label-free detections of virus-like particles (VLPs) using color images of nanoplasmonic sensing chips. The nanoplasmonic chip consists of 5×5 gold nanoslit arrays and the gold surface is modified with specific antibodies for spike protein. The resonant wavelength of the 430-nm-period gold nanoslit arrays underwater environment is about 570 nm which falls between the green and red bands of the color CCD. The captured VLPs by the specific antibodies shift the plasmonic resonance of the gold nanoslits. It results in an increased brightness of green pixels and decreased brightness of red pixels. The image contrast signals of (green - red) / (red + green) show good linearity with the surface particle density. The experimental tests show the image contrast method can detect 100-nm polystyrene particles with a surface density smaller than 2 particles/µm2. We demonstrate the application for direct detection of SARS-CoV-2 VLPs using a simple scanner platform. A detection limit smaller than 1 pg/mL with a detection time less than 30 minutes can be achieved.
Collapse
|
16
|
Zamhuri SA, Soon CF, Nordin AN, Ab Rahim R, Sultana N, Khan MA, Lim GP, Tee KS. A review on the contamination of SARS-CoV-2 in water bodies: Transmission route, virus recovery and recent biosensor detection techniques. SENSING AND BIO-SENSING RESEARCH 2022; 36:100482. [PMID: 35251937 PMCID: PMC8889793 DOI: 10.1016/j.sbsr.2022.100482] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 02/14/2022] [Accepted: 02/28/2022] [Indexed: 12/11/2022] Open
Abstract
The discovery of SARS-CoV-2 virus in the water bodies has been reported, and the risk of virus transmission to human via the water route due to poor wastewater management cannot be disregarded. The main source of the virus in water bodies is the sewage network systems which connects to the surface water. Wastewater-based epidemiology has been applied as an early surveillance tool to sense SARS-CoV-2 virus in the sewage network. This review discussed possible transmission routes of the SARS-CoV-2 virus and the challenges of the existing method in detecting the virus in wastewater. One significant challenge for the detection of the virus is that the high virus loading is diluted by the sheer volume of the wastewater. Hence, virus preconcentration from water samples prior to the application of virus assay is essential to accurately detect traceable virus loading. The preparation time, materials and conditions, virus type, recovery percentage, and various virus recovery techniques are comprehensively discussed in this review. The practicability of molecular methods such as Polymer-Chain-Reaction (PCR) for the detection of SARS-CoV-2 in wastewater will be revealed. The conventional virus detection techniques have several shortcomings and the potential of biosensors as an alternative is also considered. Biosensing techniques have also been proposed as an alternative to PCR and have reported detection limits of 10 pg/μl. This review serves to guide the reader on the future designs and development of highly sensitive, robust and, cost effective SARS-CoV-2 lab-on-a-chip biosensors for use in complex wastewater.
Collapse
Affiliation(s)
- Siti Adibah Zamhuri
- Microelectronics and Nanotechnology-Shamsuddin Research Centre, Universiti Tun Hussein Onn Malaysia, 86400, Parit Raja, Batu Pahat, Johor, Malaysia
| | - Chin Fhong Soon
- Microelectronics and Nanotechnology-Shamsuddin Research Centre, Universiti Tun Hussein Onn Malaysia, 86400, Parit Raja, Batu Pahat, Johor, Malaysia
- Faculty of Electrical and Electronic Engineering, Universiti Tun Hussein Onn Malaysia, 86400, Parit Raja, Batu Pahat, Johor, Malaysia
| | - Anis Nurashikin Nordin
- Department of Electrical and Computer Engineering, Kulliyah of Engineering, International University of Islam Malaysia, 53100, Jalan Gombak, Kuala Lumpur, Malaysia
| | - Rosminazuin Ab Rahim
- Department of Electrical and Computer Engineering, Kulliyah of Engineering, International University of Islam Malaysia, 53100, Jalan Gombak, Kuala Lumpur, Malaysia
| | | | - Muhammad Arif Khan
- Microelectronics and Nanotechnology-Shamsuddin Research Centre, Universiti Tun Hussein Onn Malaysia, 86400, Parit Raja, Batu Pahat, Johor, Malaysia
| | - Gim Pao Lim
- Microelectronics and Nanotechnology-Shamsuddin Research Centre, Universiti Tun Hussein Onn Malaysia, 86400, Parit Raja, Batu Pahat, Johor, Malaysia
| | - Kian Sek Tee
- Faculty of Electrical and Electronic Engineering, Universiti Tun Hussein Onn Malaysia, 86400, Parit Raja, Batu Pahat, Johor, Malaysia
| |
Collapse
|
17
|
Ma Y, Xiao X, Ji Q. Design of surface nanostructures for chirality sensing based on quartz crystal microbalance. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2022; 13:1201-1219. [PMID: 36348938 PMCID: PMC9623132 DOI: 10.3762/bjnano.13.100] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Accepted: 10/06/2022] [Indexed: 05/09/2023]
Abstract
Quartz crystal microbalance (QCM) has been widely used for various sensing applications, including chirality detection due to the high sensitivity to nanogram or picogram mass changes, fast response, real-time detection, easy operation, suitability in different media, and low experimental cost. The sensing performance of QCM is dependent on the surface design of the recognition layers. Various strategies have been employed for studying the relationship between the structural features and the specific detection of chiral isomers. This review provides an overview of the construction of chiral sensing layers by various nanostructures and materials in the QCM system, which include organic molecules, supermolecular assemblies, inorganic nanostructures, and metal surfaces. The sensing mechanisms based on these surface nanostructures and the related potentials for chiral detection by the QCM system are also summarized.
Collapse
Affiliation(s)
- Yinglin Ma
- Herbert Gleiter Institute for Nanoscience, School of Materials Science and Engineering, Nanjing University of Science and Technology, 200 Xiaolingwei, Nanjing, 210094, China
| | - Xiangyun Xiao
- Herbert Gleiter Institute for Nanoscience, School of Materials Science and Engineering, Nanjing University of Science and Technology, 200 Xiaolingwei, Nanjing, 210094, China
| | - Qingmin Ji
- Herbert Gleiter Institute for Nanoscience, School of Materials Science and Engineering, Nanjing University of Science and Technology, 200 Xiaolingwei, Nanjing, 210094, China
| |
Collapse
|