1
|
Kataoka H, Miyata S, Ehara K. Simultaneous Determination of Tobacco Smoke Exposure and Stress Biomarkers in Saliva Using In-Tube SPME and LC-MS/MS for the Analysis of the Association between Passive Smoking and Stress. Molecules 2024; 29:4157. [PMID: 39275005 PMCID: PMC11397470 DOI: 10.3390/molecules29174157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Revised: 08/24/2024] [Accepted: 08/31/2024] [Indexed: 09/16/2024] Open
Abstract
Passive smoking from environmental tobacco smoke not only increases the risk of lung cancer and cardiovascular disease but may also be a stressor triggering neuropsychiatric and other disorders. To prevent these diseases, understanding the relationship between passive smoking and stress is vital. In this study, we developed a simple and sensitive method to simultaneously measure nicotine (Nic) and cotinine (Cot) as tobacco smoke exposure biomarkers, and cortisol (CRT), serotonin (5-HT), melatonin (MEL), dopamine (DA), and oxytocin (OXT) as stress-related biomarkers. These were extracted and concentrated from saliva by in-tube solid-phase microextraction (IT-SPME) using a Supel-Q PLOT capillary as the extraction device, then separated and detected within 6 min by liquid chromatography-tandem mass spectrometry (LC-MS/MS) using a Kinetex Biphenyl column (Phenomenex Inc., Torrance, CA, USA). Limits of detection (S/N = 3) for Nic, Cot, CRT, 5-HT, MEL, DA, and OXT were 0.22, 0.12, 0.78, 0.39, 0.45, 1.4, and 3.7 pg mL-1, respectively, with linearity of calibration curves in the range of 0.01-25 ng mL-1 using stable isotope-labeled internal standards. Intra- and inter-day reproducibilities were under 7.9% and 14.6% (n = 5) relative standard deviations, and compound recoveries in spiked saliva samples ranged from 82.1 to 106.6%. In thirty nonsmokers, Nic contents positively correlated with CRT contents (R2 = 0.5264, n = 30), while no significant correlation was found with other biomarkers. The standard deviation of intervals between normal beats as the standard measure of heart rate variability analysis negatively correlated with CRT contents (R2 = 0.5041, n = 30). After passive smoke exposure, Nic levels transiently increased, Cot and CRT levels rose over time, and 5-HT, DA, and OXT levels decreased. These results indicate tobacco smoke exposure acts as a stressor in nonsmokers.
Collapse
Affiliation(s)
- Hiroyuki Kataoka
- School of Pharmacy, Shujitsu University, Okayama 703-8516, Japan
| | - Saori Miyata
- School of Pharmacy, Shujitsu University, Okayama 703-8516, Japan
| | - Kentaro Ehara
- School of Pharmacy, Shujitsu University, Okayama 703-8516, Japan
| |
Collapse
|
2
|
Hu B. Non-invasive Sampling of Human Body Fluids Using In Vivo SPME. EVOLUTION OF SOLID PHASE MICROEXTRACTION TECHNOLOGY 2023:451-465. [DOI: 10.1039/bk9781839167300-00451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Noninvasive body fluids offer attractive sources to gain insights into human health. The in vivo solid-phase microextraction (SPME) technique is a fast and versatile sample preparation technique for the noninvasive sampling of human body fluids in various fields. This chapter summarizes the applications of SPME coupled with mass spectrometry (MS)-based approaches for noninvasive investigations of human body fluids, including urine, sweat, and saliva. New features of noninvasive SPME sampling and MS-based analysis are highlighted, and the prospects on their further development are also discussed.
Collapse
Affiliation(s)
- Bin Hu
- Institute of Mass Spectrometry and Atmospheric Environment Jinan University Guangzhou 510632 China
| |
Collapse
|
3
|
Kumar D, Azad RMR, Oulkar D, Oberoi HS, Jacob S, Koner BC, Sonkar SC. A quantification method for trace level of oxytocin in food matrices using LC-MS/MS. FRONTIERS IN ANALYTICAL SCIENCE 2022; 2. [DOI: 10.3389/frans.2022.1039606] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Abstract
Backgrounds: Oxytocin is nowadays used to increase the agricultural products besides its use during the milking of cattle leading to the contamination of agricultural produce and milk with oxytocin. Monitoring of accurate oxytocin contaminations from foodstuffs is sometimes required to maintain the quality standard. The commonly used oxytocin assays in this study were interfered with by the food matrix. There is a need to develop an accurate and confirmed method for monitoring oxytocin contaminations in foodstuffs.Objective: An attempt is made to develop an accurate assay method of oxytocin from milk and agricultural produces.Methods: The acidified methanol was used for the extraction of oxytocin from target food stuff/matrices (agricultural produce and Milk). LC-MS/MS was used for its detection and quantification. In the chromatographic separation, Oxytocin concentration was optimized using selective reaction monitoring (SRM) with heated electrospray ionization (HESI) in positive polarity. The chromatographic separation was performed using a reversed-phase C18 column with gradient elution at a flow rate of 0.4 ml/min. The acidified methanol was used for the extraction of oxytocin in all target food matrices. The method performance was verified as per the SANTE 2021 guideline. After method validation, the method was applied in real food samples analysis for assessing the presence/absence of oxytocin.Results: The calibration curve offered excellent linearity (R2 = 0.999) with less than 15% residuals. The matrix effect was <20% observed for all target matrices. The mean recoveries were within 70%–115% with <11% RSD at four different levels in milk and 0.01 mg/kg in fruits and vegetables. The optimized method was applied to 50 random samples of milk, fruits, and vegetables from the market for the purposes of an established quality control approach. Based on the results, we did observe a signal of oxytocin in the random samples Therefore, this method has shown its practical suitability for the detection of oxytocin in milk, fruits, and vegetables.Conclusion: Extraction of oxytocin using acidified methanol followed by assays using LC-MS/MS is a simple, sensitive, accurate, reproducible, and practically suitable method for detection and quantification of oxytocin from milk, fruits, and vegetables.
Collapse
|
4
|
Grecco CF, Souza ID, Queiroz MEC. Novel materials as capillary coatings for in‐tube solid‐phase microextraction for bioanalysis. J Sep Sci 2021; 44:1662-1693. [DOI: 10.1002/jssc.202001070] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 01/11/2021] [Accepted: 01/31/2021] [Indexed: 12/18/2022]
Affiliation(s)
- Caroline Fernandes Grecco
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| | - Israel Donizeti Souza
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| | - Maria Eugênia Costa Queiroz
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| |
Collapse
|
5
|
Manousi N, Tzanavaras PD, Zacharis CK. Bioanalytical HPLC Applications of In-Tube Solid Phase Microextraction: A Two-Decade Overview. Molecules 2020; 25:molecules25092096. [PMID: 32365828 PMCID: PMC7248733 DOI: 10.3390/molecules25092096] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 04/28/2020] [Accepted: 04/29/2020] [Indexed: 12/18/2022] Open
Abstract
In-tube solid phase microextraction is a cutting-edge sample treatment technique offering significant advantages in terms of miniaturization, green character, automation, and preconcentration prior to analysis. During the past years, there has been a considerable increase in the reported publications, as well as in the research groups focusing their activities on this technique. In the present review article, HPLC bioanalytical applications of in-tube SPME are discussed, covering a wide time frame of twenty years of research reports. Instrumental aspects towards the coupling of in-tube SPME and HPLC are also discussed, and detailed information on materials/coatings and applications in biological samples are provided.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Paraskevas D. Tzanavaras
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Constantinos K. Zacharis
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
- Correspondence: ; Tel.: +30-231-099-7663
| |
Collapse
|
6
|
Locatelli M, Tartaglia A, Piccolantonio S, Di Iorio LA, Sperandio E, Ulusoy HI, Furton KG, Kabir A. Innovative Configurations of Sample Preparation Techniques Applied in Bioanalytical Chemistry: A Review. CURR ANAL CHEM 2019. [DOI: 10.2174/1573411015666190301145042] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Background:
Recently, in all fields of analytical chemistry, increased attention has been
paid to extraction procedures and instrumental methods, which are easily scalable and are able to automate
in order to improve the “high-throughput” capability.
Introduction:
The main goal of these applications relates to an improvement of the precision in the
quantitative analysis, reduction of different sources of errors, decrease the analysis time and, in general,
improve the analytical performances. Often these points can be in contrast to each other, not allowing
to achieve the expected result but forcing a compromise between the objectives of the method
and the analytical performance.
Methods:
In this review, following the evolution of the (micro)extraction procedures and instrument
configurations, the recent procedures used in bioanalytical chemistry are critically evaluated. The
aim of this paper is providing an overview of the approaches available in order to perform on-line
coupling of various extraction techniques with chromatographic methods for the analysis of different
compounds in various samples. Furthermore, a comparison between off-line and on-line systems, advantages
of on-line systems applied on major extractive techniques and future perspectives are described.
Result:
The extraction methods suitable for on-line coupling covered in this review are: liquid-liquid
extraction (LLE), solid phase extraction (SPE), solid phase microextraction (SPME), dispersive liquid-
liquid microextraction (DLLME), microextraction by packed sorbent (MEPS), supercritical fluid
extraction (SFE) and fabric phase sorptive extraction (FPSE).
Conclusion:
An overview of the micro-extraction techniques mentioned above was provided, making
a comparison between them and focusing attention on future perspectives.
Collapse
Affiliation(s)
- Marcello Locatelli
- Department of Pharmacy, University “G. d’Annunzio” of Chieti-Pescara, Chieti (CH), Italy
| | - Angela Tartaglia
- Department of Pharmacy, University “G. d’Annunzio” of Chieti-Pescara, Chieti (CH), Italy
| | - Silvia Piccolantonio
- Department of Pharmacy, University “G. d’Annunzio” of Chieti-Pescara, Chieti (CH), Italy
| | | | - Elena Sperandio
- Department of Pharmacy, University “G. d’Annunzio” of Chieti-Pescara, Chieti (CH), Italy
| | - Halil Ibrahim Ulusoy
- Faculty of Pharmacy, Department of Analytical Chemistry, Cumhuriyet University, Sivas, Turkey
| | - Kenneth G. Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, United States
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, United States
| |
Collapse
|
7
|
Wang L, Marti DW, Anderson RE. Development and Validation of a Simple LC-MS Method for the Quantification of Oxytocin in Dog Saliva. Molecules 2019; 24:E3079. [PMID: 31450590 PMCID: PMC6749683 DOI: 10.3390/molecules24173079] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 08/19/2019] [Accepted: 08/22/2019] [Indexed: 11/16/2022] Open
Abstract
Oxytocin (OT) is a mammalian neuropeptide with various functions in regulating birth, lactation, parenting, and social recognition. The study of OT became of increasing interest for the petcare industry due to its role in animal behavior and socialization. In the present study, a simple, sensitive, and accurate liquid chromatography-mass spectrometry (LC-MS) method for quantifying OT in dog saliva was developed and validated. OT and its deuterated internal standard (OT-d5) were detected with multiple reaction monitoring (MRM) in a positive ion mode using an AB Sciex 6500+ QTRAP mass spectrometer. Chromatographic separation was achieved by using an ACE Excel C18 column and a gradient elution at a flow rate of 0.5 mL/min over a 5 min run. The mobile phases consisted of 0.1% (v/v) acetic acid in water and 0.1% (v/v) acetic acid in acetonitrile. After development and optimization, the performance of the method was validated to prove its reliability. Calibration curves were linear over the range of 50-20,000 pg/mL and recovery of OT was above 87.8%. The validated method was successfully applied to evaluate OT concentrations in multiple batches of dog saliva samples.
Collapse
Affiliation(s)
- Lei Wang
- Nestlé Purina Research, Nestlé Purina PetCare, Saint Joseph, MO 64503, USA.
| | - Dakota W Marti
- Nestlé Purina Research, Nestlé Purina PetCare, Saint Joseph, MO 64503, USA
| | - Rachel E Anderson
- Nestlé Purina Research, Nestlé Purina PetCare, Saint Joseph, MO 64503, USA
| |
Collapse
|
8
|
Hamidi S, Alipour-Ghorbani N, Hamidi A. Solid Phase Microextraction Techniques in Determination of Biomarkers. Crit Rev Anal Chem 2018; 48:239-251. [DOI: 10.1080/10408347.2017.1396885] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Samin Hamidi
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Nastaran Alipour-Ghorbani
- Research Laboratory of Dendrimers and Nanopolymers, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Aliasghar Hamidi
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Medicinal Chemistry, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|