1
|
Buhas BA, Toma V, Beauval JB, Andras I, Couți R, Muntean LAM, Coman RT, Maghiar TA, Știufiuc RI, Lucaciu CM, Crisan N. Label-Free SERS of Urine Components: A Powerful Tool for Discriminating Renal Cell Carcinoma through Multivariate Analysis and Machine Learning Techniques. Int J Mol Sci 2024; 25:3891. [PMID: 38612705 PMCID: PMC11011951 DOI: 10.3390/ijms25073891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 03/29/2024] [Accepted: 03/29/2024] [Indexed: 04/14/2024] Open
Abstract
The advent of Surface-Enhanced Raman Scattering (SERS) has enabled the exploration and detection of small molecules, particularly in biological fluids such as serum, blood plasma, urine, saliva, and tears. SERS has been proposed as a simple diagnostic technique for various diseases, including cancer. Renal cell carcinoma (RCC) ranks as the sixth most commonly diagnosed cancer in men and is often asymptomatic, with detection occurring incidentally. The onset of symptoms typically aligns with advanced disease, aggressive histology, and unfavorable prognosis, and therefore new methods for an early diagnosis are needed. In this study, we investigated the utility of label-free SERS in urine, coupled with two multivariate analysis approaches: Principal Component Analysis combined with Linear Discriminant Analysis (PCA-LDA) and Support Vector Machine (SVM), to discriminate between 50 RCC patients and 44 healthy donors. Employing LDA-PCA, we achieved a discrimination accuracy of 100% using 13 principal components, and an 88% accuracy in discriminating between different RCC stages. The SVM approach yielded a training accuracy of 100%, a validation accuracy of 99% for discriminating between RCC and controls, and an 80% accuracy for discriminating between stages. The comparative analysis of raw and normalized SERS spectral data shows that while raw data disclose relative concentration variations in urine metabolites between the two classes, the normalization of spectral data significantly improves the accuracy of discrimination. Moreover, the selection of principal components with markedly distinct scores between the two classes serves to alleviate overfitting risks and reduces the number of components employed for discrimination. We obtained the accuracy of the discrimination between the RCC patients cases and healthy donors of 90% for three PCs and a linear discrimination function, and a 88% accuracy of discrimination between stages using six PCs, mitigating practically the risk of overfitting and increasing the robustness of our analysis. Our findings underscore the potential of label-free SERS of urine in conjunction with chemometrics for non-invasive and early RCC detection.
Collapse
Affiliation(s)
- Bogdan Adrian Buhas
- Department of Urology, La Croix du Sud Hospital, 52 Chemin de Ribaute St., 31130 Quint Fonsegrives, France; (B.A.B.); (J.-B.B.)
- Department of Urology, Clinical Municipal Hospital, 11 Tabacarilor St., 400139 Cluj-Napoca, Romania; (I.A.); (N.C.)
- Faculty of Medicine and Pharmacy, University of Oradea, 1 Universitatii St., 410087 Oradea, Romania; (R.C.); (T.A.M.)
| | - Valentin Toma
- Department of Nanobiophysics, MedFuture Research Center for Advanced Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, 4-6 Pasteur St., 400337 Cluj-Napoca, Romania;
| | - Jean-Baptiste Beauval
- Department of Urology, La Croix du Sud Hospital, 52 Chemin de Ribaute St., 31130 Quint Fonsegrives, France; (B.A.B.); (J.-B.B.)
| | - Iulia Andras
- Department of Urology, Clinical Municipal Hospital, 11 Tabacarilor St., 400139 Cluj-Napoca, Romania; (I.A.); (N.C.)
- Faculty of Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, 8 Victor Babes St., 400347 Cluj-Napoca, Romania
| | - Răzvan Couți
- Faculty of Medicine and Pharmacy, University of Oradea, 1 Universitatii St., 410087 Oradea, Romania; (R.C.); (T.A.M.)
| | - Lucia Ana-Maria Muntean
- Department of Medical Education, “Iuliu Hatieganu” University of Medicine and Pharmacy, 8 Victor Babes St., 400347 Cluj-Napoca, Romania;
| | - Radu-Tudor Coman
- Faculty of Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, 8 Victor Babes St., 400347 Cluj-Napoca, Romania
| | - Teodor Andrei Maghiar
- Faculty of Medicine and Pharmacy, University of Oradea, 1 Universitatii St., 410087 Oradea, Romania; (R.C.); (T.A.M.)
| | - Rareș-Ionuț Știufiuc
- Department of Nanobiophysics, MedFuture Research Center for Advanced Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, 4-6 Pasteur St., 400337 Cluj-Napoca, Romania;
- Department of Pharmaceutical Physics–Biophysics, Faculty of Pharmacy, “Iuliu Hatieganu” University of Medicine and Pharmacy, 6 Pasteur St., 400349 Cluj-Napoca, Romania
- Nanotechnology Laboratory, TRANSCEND Research Center, Regional Institute of Oncology, 700483 Iași, Romania
| | - Constantin Mihai Lucaciu
- Department of Pharmaceutical Physics–Biophysics, Faculty of Pharmacy, “Iuliu Hatieganu” University of Medicine and Pharmacy, 6 Pasteur St., 400349 Cluj-Napoca, Romania
| | - Nicolae Crisan
- Department of Urology, Clinical Municipal Hospital, 11 Tabacarilor St., 400139 Cluj-Napoca, Romania; (I.A.); (N.C.)
- Faculty of Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, 8 Victor Babes St., 400347 Cluj-Napoca, Romania
| |
Collapse
|
2
|
Espinosa-Garavito AC, Quiroz EN, Galán-Freyle NJ, Aroca-Martinez G, Hernández-Rivera SP, Villa-Medina J, Méndez-López M, Gomez-Escorcia L, Acosta-Hoyos A, Pacheco-Lugo L, Espitia-Almeida F, Pacheco-Londoño LC. Surface-enhanced Raman Spectroscopy in urinalysis of hypertension patients with kidney disease. Sci Rep 2024; 14:3035. [PMID: 38321263 PMCID: PMC10847430 DOI: 10.1038/s41598-024-53679-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 02/03/2024] [Indexed: 02/08/2024] Open
Abstract
Arterial hypertension (AH) is a multifactorial and asymptomatic disease that affects vital organs such as the kidneys and heart. Considering its prevalence and the associated severe health repercussions, hypertension has become a disease of great relevance for public health across the globe. Conventionally, the classification of an individual as hypertensive or non-hypertensive is conducted through ambulatory blood pressure monitoring over a 24-h period. Although this method provides a reliable diagnosis, it has notable limitations, such as additional costs, intolerance experienced by some patients, and interferences derived from physical activities. Moreover, some patients with significant renal impairment may not present proteinuria. Accordingly, alternative methodologies are applied for the classification of individuals as hypertensive or non-hypertensive, such as the detection of metabolites in urine samples through liquid chromatography or mass spectrometry. However, the high cost of these techniques limits their applicability for clinical use. Consequently, an alternative methodology was developed for the detection of molecular patterns in urine collected from hypertension patients. This study generated a direct discrimination model for hypertensive and non-hypertensive individuals through the amplification of Raman signals in urine samples based on gold nanoparticles and supported by chemometric techniques such as partial least squares-discriminant analysis (PLS-DA). Specifically, 162 patient urine samples were used to create a PLS-DA model. These samples included 87 urine samples from patients diagnosed with hypertension and 75 samples from non-hypertensive volunteers. In the AH group, 35 patients were diagnosed with kidney damage and were further classified into a subgroup termed (RAH). The PLS-DA model with 4 latent variables (LV) was used to classify the hypertensive patients with external validation prediction (P) sensitivity of 86.4%, P specificity of 77.8%, and P accuracy of 82.5%. This study demonstrates the ability of surface-enhanced Raman spectroscopy to differentiate between hypertensive and non-hypertensive patients through urine samples, representing a significant advance in the detection and management of AH. Additionally, the same model was then used to discriminate only patients diagnosed with renal damage and controls with a P sensitivity of 100%, P specificity of 77.8%, and P accuracy of 82.5%.
Collapse
Affiliation(s)
- Alberto C Espinosa-Garavito
- Centro de Investigaciones en Ciencias de la Vida, Facultad de Ciencias Básicas y Biomédicas, Universidad Simón Bolívar, 080002, Barranquilla, Atlántico, Colombia
| | - Elkin Navarro Quiroz
- Centro de Investigaciones en Ciencias de la Vida, Facultad de Ciencias Básicas y Biomédicas, Universidad Simón Bolívar, 080002, Barranquilla, Atlántico, Colombia
| | - Nataly J Galán-Freyle
- Centro de Investigaciones en Ciencias de la Vida, Facultad de Ciencias Básicas y Biomédicas, Universidad Simón Bolívar, 080002, Barranquilla, Atlántico, Colombia
| | | | - Samuel P Hernández-Rivera
- Center for Chemical Sensors, DHS SENTRY COE, University of Puerto Rico-Mayaguez, Mayaguez, PR, 00681, USA
| | - Joe Villa-Medina
- Center of Pharmaceutical Research, Procaps Laboratories, 080002, Barranquilla, Colombia
| | - Maximiliano Méndez-López
- Grupo de Química y Biología, Departamento de Química y Biología, Universidad del Norte, Km 5 Vía Puerto Colombia, 080001, Barranquilla, Colombia
| | | | - Antonio Acosta-Hoyos
- Centro de Investigaciones en Ciencias de la Vida, Facultad de Ciencias Básicas y Biomédicas, Universidad Simón Bolívar, 080002, Barranquilla, Atlántico, Colombia
| | - Lisandro Pacheco-Lugo
- Centro de Investigaciones en Ciencias de la Vida, Facultad de Ciencias Básicas y Biomédicas, Universidad Simón Bolívar, 080002, Barranquilla, Atlántico, Colombia
| | - Fabián Espitia-Almeida
- Centro de Investigaciones en Ciencias de la Vida, Facultad de Ciencias Básicas y Biomédicas, Universidad Simón Bolívar, 080002, Barranquilla, Atlántico, Colombia
| | - Leonardo C Pacheco-Londoño
- Centro de Investigaciones en Ciencias de la Vida, Facultad de Ciencias Básicas y Biomédicas, Universidad Simón Bolívar, 080002, Barranquilla, Atlántico, Colombia.
| |
Collapse
|
3
|
Chen X, Chen C, Tian X, He L, Zuo E, Liu P, Xue Y, Yang J, Chen C, Lv X. DBAN: An improved dual branch attention network combined with serum Raman spectroscopy for diagnosis of diabetic kidney disease. Talanta 2024; 266:125052. [PMID: 37574605 DOI: 10.1016/j.talanta.2023.125052] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 08/02/2023] [Accepted: 08/05/2023] [Indexed: 08/15/2023]
Abstract
Diabetic kidney disease (DKD) is one of the most common kidney diseases worldwide. It is estimated that approximately 537 million adults worldwide have diabetes, and up to 30%-40% of diabetic patients are at risk of developing nephropathy. The pathogenesis of DKD is complex, and its onset is insidious. Currently, the clinical diagnosis of DKD primarily relies on the increase of urinary albumin and the decrease in glomerular filtration rate in diabetic patients. However, the excretion of urinary albumin is influenced by various factors, such as physical activity, infections, fever, and high blood glucose, making it challenging to achieve an objective and accurate diagnosis. Therefore, there is an urgent need to develop an efficient, fast, and low-cost auxiliary diagnostic technology for DKD. In this study, an improved Dual Branch Attention Network (DBAN) was developed to quickly identify DKD. Serum Raman spectroscopy samples were collected from 32 DKD patients and 32 healthy volunteers. The collected data were preprocessed using the adaptive iteratively reweighted penalized least squares (airPLS) algorithm, and the DBAN was used to classify the serum Raman spectroscopy data of DKD. The model consists of a dual branch structure that extracts features using Convolutional Neural Network (CNN) and bottleneck layer modules. The attention module allows the model to learn features specifically, and lateral connections are added between the dual branches to achieve multi-level and multi-scale fusion of shallow and deep features, as well as local and global features, improving the classification accuracy of the experiment. The results of the study showed that compared to traditional deep learning algorithms such as Artificial Neural Network (ANN), CNN, GoogleNet, ResNet, and AlexNet, our proposed DBAN classification model achieved 95.4% accuracy, 98.0% precision, 96.5% sensitivity, and 97.2% specificity, demonstrating the best classification performance. This is the best method for identifying DKD, and has important reference value for the diagnosis of DKD patients, as well as improving the accuracy of medical auxiliary diagnosis.
Collapse
Affiliation(s)
- Xinya Chen
- College of Information Science and Engineering, Xinjiang University, Urumqi, 830046, China
| | - Chen Chen
- College of Information Science and Engineering, Xinjiang University, Urumqi, 830046, China
| | - Xuecong Tian
- College of Information Science and Engineering, Xinjiang University, Urumqi, 830046, China
| | - Liang He
- College of Information Science and Engineering, Xinjiang University, Urumqi, 830046, China; Xinjiang Key Laboratory of Signal Detection and Processing, Urumqi, 830017,China; Department of Electronic Engineering, and Beijing National Research Center for Information Science and Technology, Tsinghua University, Beijing, 100084, China
| | - Enguang Zuo
- College of Information Science and Engineering, Xinjiang University, Urumqi, 830046, China
| | - Pei Liu
- College of Information Science and Engineering, Xinjiang University, Urumqi, 830046, China
| | - You Xue
- College of Information Science and Engineering, Xinjiang University, Urumqi, 830046, China
| | - Jie Yang
- College of Information Science and Engineering, Xinjiang University, Urumqi, 830046, China
| | - Cheng Chen
- College of Software, Xinjiang University, Urumqi, 830046, China.
| | - Xiaoyi Lv
- College of Software, Xinjiang University, Urumqi, 830046, China; The Key Laboratory of Signal Detection and Processing, Xinjiang Uygur Autonomous Region, Xinjiang University, Urumqi, 840046, China.
| |
Collapse
|
4
|
Vazquez-Osorio N, Castro-Ramos J, Sánchez-Escobar JJ. Matching Pursuit for Denoising Raman Spectra, Based on Genetic Algorithm and Hermite Atoms. APPLIED SPECTROSCOPY 2023; 77:1009-1024. [PMID: 37448352 DOI: 10.1177/00037028231179744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/15/2023]
Abstract
Due to its various advantages, Raman spectroscopy has become a powerful tool in different fields of science and engineering; however, in specific applications, this technique's limiting factor is closely related to the inherent noise of the Raman spectra. To eliminate the noise of a Raman spectrum, preserving its position, intensity, and width characteristic, we propose using a genetic matching pursuit-Hermite atoms (GMP-HAs) algorithm in this work. This algorithm helps recover Raman spectra immersed in Gaussian noise with the least number of atoms. The noise-free Raman signal is reconstructed with the GMP-HAs algorithm, transforming the typical best-matching atom search into an optimization problem. Specifically, we maximize the fitness function, defined as the correlation between current residual and Hermite atoms, with the genetic algorithm MI-LXPM encoded in a real domain and avoiding local maxima, by adding a stopping criterion based on an exponential adjustment according to the algorithm's behavior in the presence of noise. Simulated and biological Raman spectra are used to evaluate the proposed algorithm and compare its performance with typically known methods for denoising, such as the Savitzky- Golay filter (SG) and basis pursuit denoising. Using the signal-to-noise ratio (S/N)metric resulted in a 0.31 dB advantage in the S/N product for the proposed algorithm with respect to SG. Additionally, it is shown that the algorithm uses only 25.3% of the number of atoms needed by the matching pursuit algorithm. The results indicate that the GMP-HAs algorithm has better denoising capabilities, and at the same time, the Raman spectra are decomposed with fewer atoms compared to known sparse algorithms.
Collapse
Affiliation(s)
- Noe Vazquez-Osorio
- Coordinación de Óptica, Instituto Nacional de Astrofísica, Óptica y Electrónica, Puebla, Mexico
| | - J Castro-Ramos
- Coordinación de Óptica, Instituto Nacional de Astrofísica, Óptica y Electrónica, Puebla, Mexico
| | | |
Collapse
|
5
|
Zhang X, Song X, Li W, Chen C, Wusiman M, Zhang L, Zhang J, Lu J, Lu C, Lv X. Rapid diagnosis of membranous nephropathy based on serum and urine Raman spectroscopy combined with deep learning methods. Sci Rep 2023; 13:3418. [PMID: 36854769 PMCID: PMC9974944 DOI: 10.1038/s41598-022-22204-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 10/11/2022] [Indexed: 03/02/2023] Open
Abstract
Membranous nephropathy is the main cause of nephrotic syndrome, which has an insidious onset and may progress to end-stage renal disease with a high mortality rate, such as renal failure and uremia. At present, the diagnosis of membranous nephropathy mainly relies on the clinical manifestations of patients and pathological examination of kidney biopsy, which are expensive, time-consuming, and have certain chance and other disadvantages. Therefore, there is an urgent need to find a rapid, accurate and non-invasive diagnostic technique for the diagnosis of membranous nephropathy. In this study, Raman spectra of serum and urine were combined with deep learning methods to diagnose membranous nephropathy. After baseline correction and smoothing of the data, Gaussian white noise of different decibels was added to the training set for data amplification, and the amplified data were imported into ResNet, AlexNet and GoogleNet models to obtain the evaluation results of the models for membranous nephropathy. The experimental results showed that the three deep learning models achieved an accuracy of 1 for the classification of serum data of patients with membranous nephropathy and control group, and the discrimination of urine data was above 0.85, among which AlexNet was the best classification model for both samples. The above experimental results illustrate the great potential of serum- and urine-based Raman spectroscopy combined with deep learning methods for rapid and accurate identification of patients with membranous nephropathy.
Collapse
Affiliation(s)
- Xueqin Zhang
- grid.410644.3People’s Hospital of Xinjiang Uygur Autonomous Region, Urumqi, 830001 China
| | - Xue Song
- grid.410644.3People’s Hospital of Xinjiang Uygur Autonomous Region, Urumqi, 830001 China
| | - Wenjing Li
- grid.413254.50000 0000 9544 7024College of Software, Xinjiang University, Urumqi, 830046 China
| | - Cheng Chen
- grid.413254.50000 0000 9544 7024College of Software, Xinjiang University, Urumqi, 830046 China
| | - Miriban Wusiman
- grid.13394.3c0000 0004 1799 3993Xinjiang Medical University, Urumqi, 830054 China
| | - Li Zhang
- grid.412631.3The First Affiliated Hospital of Xinjiang Medical University, Urumqi, 830011 China
| | - Jiahui Zhang
- grid.13394.3c0000 0004 1799 3993Xinjiang Medical University, Urumqi, 830054 China
| | - Jinyu Lu
- grid.410644.3People’s Hospital of Xinjiang Uygur Autonomous Region, Urumqi, 830001 China
| | - Chen Lu
- The First Affiliated Hospital of Xinjiang Medical University, Urumqi, 830011, China.
| | - Xiaoyi Lv
- College of Software, Xinjiang University, Urumqi, 830046, China.
| |
Collapse
|
6
|
Aitekenov S, Sultangaziyev A, Boranova A, Dyussupova A, Ilyas A, Gaipov A, Bukasov R. SERS for Detection of Proteinuria: A Comparison of Gold, Silver, Al Tape, and Silicon Substrates for Identification of Elevated Protein Concentration in Urine. SENSORS (BASEL, SWITZERLAND) 2023; 23:1605. [PMID: 36772644 PMCID: PMC9921516 DOI: 10.3390/s23031605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 01/23/2023] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
Excessive protein excretion in human urine is an early and sensitive marker of diabetic nephropathy and primary and secondary renal disease. Kidney problems, particularly chronic kidney disease, remain among the few growing causes of mortality in the world. Therefore, it is important to develop an efficient, expressive, and low-cost method for protein determination. Surface enhanced Raman spectroscopy (SERS) methods are potential candidates to achieve these criteria. In this paper, a SERS method was developed to distinguish patients with proteinuria from the healthy group. Commercial gold nanoparticles (AuNPs) with diameters of 60 nm and 100 nm, and silver nanoparticles (AgNPs) with a diameter of 100 nm were tested on the surface of four different substrates including silver and gold films, silicon, and aluminum tape. SERS spectra were acquired from 111 unique human urine samples prepared and measured for each of the seven different nanoparticle plus substrate combinations. Data analysis by the PCA-LDA algorithm and the ROC curves gave results for the diagnostic figures of merits. The best sensitivity, specificity, accuracy, and AUC were 0.91, 0.84, 0.88, and 0.94 for the set with 100 nm Au NPs on the silver substrate, respectively. Among the three metal substrates, the substrate with AuNPs and Al tape performed slightly worse than the other three substrates, and 100 nm gold nanoparticles on average produced better results than 60 nm gold nanoparticles. The 60 nm diameter AuNPs and silicon, which is about one order of magnitude more cost-effective than AuNPs and gold film, showed a relative performance close to the performance of 60 nm AuNPs and Au film (average AUC 0.88 (Si) vs. 0.89 (Au)). This is likely the first reported application of unmodified silicon in SERS substrates applied for direct detection of proteins in any biofluid, particularly in urine. These results position silicon and AuNPs@Si in particular as a perspective SERS substrate for direct urine analysis, including clinical diagnostics of proteinuria.
Collapse
Affiliation(s)
- Sultan Aitekenov
- Department of Chemistry, School of Sciences and Humanities (SSH) Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| | - Alisher Sultangaziyev
- Department of Chemistry, School of Sciences and Humanities (SSH) Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| | - Aigerim Boranova
- Department of Chemistry, School of Sciences and Humanities (SSH) Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| | - Aigerim Dyussupova
- Department of Chemistry, School of Sciences and Humanities (SSH) Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| | - Aisha Ilyas
- Department of Chemistry, School of Sciences and Humanities (SSH) Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| | - Abduzhappar Gaipov
- Department of Medicine, School of Medicine, Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| | - Rostislav Bukasov
- Department of Chemistry, School of Sciences and Humanities (SSH) Nazarbayev University, Nur-Sultan 010000, Kazakhstan
| |
Collapse
|
7
|
Delrue C, Speeckaert MM. The Potential Applications of Raman Spectroscopy in Kidney Diseases. J Pers Med 2022; 12:jpm12101644. [PMID: 36294783 PMCID: PMC9604710 DOI: 10.3390/jpm12101644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 09/09/2022] [Accepted: 09/29/2022] [Indexed: 12/23/2022] Open
Abstract
Raman spectroscopy (RS) is a spectroscopic technique based on the inelastic interaction of incident electromagnetic radiation (from a laser beam) with a polarizable molecule, which, when scattered, carries information from molecular vibrational energy (the Raman effect). RS detects biochemical changes in biological samples at the molecular level, making it an effective analytical technique for disease diagnosis and prognosis. It outperforms conventional sample preservation techniques by requiring no chemical reagents, reducing analysis time even at low concentrations, and working in the presence of interfering agents or solvents. Because routinely utilized biomarkers for kidney disease have limitations, there is considerable interest in the potential use of RS. RS may identify and quantify urinary and blood biochemical components, with results comparable to reference methods in nephrology.
Collapse
Affiliation(s)
- Charlotte Delrue
- Department of Nephrology, Ghent University Hospital, 9000 Ghent, Belgium
| | - Marijn M. Speeckaert
- Department of Nephrology, Ghent University Hospital, 9000 Ghent, Belgium
- Research Foundation-Flanders (FWO), 1000 Brussels, Belgium
- Correspondence: ; Tel.: +32-9-332-4509
| |
Collapse
|
8
|
Ralbovsky NM, Lednev IK. Vibrational Spectroscopy for Detection of Diabetes: A Review. APPLIED SPECTROSCOPY 2021; 75:929-946. [PMID: 33988040 DOI: 10.1177/00037028211019130] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Type II diabetes mellitus (T2DM) is a metabolic disorder that is characterized by chronically elevated glucose caused by insulin resistance. Although T2DM is manageable through insulin therapy, the disorder itself is a risk factor for much more dangerous diseases including cardiovascular disease, kidney disease, retinopathy, Alzheimer's disease, and more. T2DM affects 450 million people worldwide and is attributed to causing over four million deaths each year. Current methods for detecting diabetes typically involve testing a person's glycated hemoglobin levels as well as blood sugar levels randomly or after fasting. However, these methods can be problematic due to an individual's levels differing on a day-to-day basis or being affected by diet or environment, and due to the lack of sensitivity and reliability within the tests themselves. Vibrational spectroscopic methods have been pursued as a novel method for detecting diabetes accurately and early in a minimally invasive manner. This review summarizes recent research, since 2015, which has used infrared or Raman spectroscopy for the purpose of developing a fast and accurate method for diagnosing diabetes. Based on critical evaluation of the reviewed work, vibrational spectroscopy has the potential to improve and revolutionize the way diabetes is diagnosed, thereby allowing for faster and more effective treatment of the disorder.
Collapse
Affiliation(s)
| | - Igor K Lednev
- Department of Chemistry, University at Albany, Albany, NY, USA
| |
Collapse
|