1
|
Martín-González S, Ravelo-García AG, Navarro-Mesa JL, Hernández-Pérez E. Combining Heart Rate Variability and Oximetry to Improve Apneic Event Screening in Non-Desaturating Patients. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094267. [PMID: 37177472 PMCID: PMC10181515 DOI: 10.3390/s23094267] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 04/17/2023] [Accepted: 04/18/2023] [Indexed: 05/15/2023]
Abstract
In this paper, we thoroughly analyze the detection of sleep apnea events in the context of Obstructive Sleep Apnea (OSA), which is considered a public health problem because of its high prevalence and serious health implications. We especially evaluate patients who do not always show desaturations during apneic episodes (non-desaturating patients). For this purpose, we use a database (HuGCDN2014-OXI) that includes desaturating and non-desaturating patients, and we use the widely used Physionet Apnea Dataset for a meaningful comparison with prior work. Our system combines features extracted from the Heart-Rate Variability (HRV) and SpO2, and it explores their potential to characterize desaturating and non-desaturating events. The HRV-based features include spectral, cepstral, and nonlinear information (Detrended Fluctuation Analysis (DFA) and Recurrence Quantification Analysis (RQA)). SpO2-based features include temporal (variance) and spectral information. The features feed a Linear Discriminant Analysis (LDA) classifier. The goal is to evaluate the effect of using these features either individually or in combination, especially in non-desaturating patients. The main results for the detection of apneic events are: (a) Physionet success rate of 96.19%, sensitivity of 95.74% and specificity of 95.25% (Area Under Curve (AUC): 0.99); (b) HuGCDN2014-OXI of 87.32%, 83.81% and 88.55% (AUC: 0.934), respectively. The best results for the global diagnosis of OSA patients (HuGCDN2014-OXI) are: success rate of 95.74%, sensitivity of 100%, and specificity of 89.47%. We conclude that combining both features is the most accurate option, especially when there are non-desaturating patterns among the recordings under study.
Collapse
Affiliation(s)
- Sofía Martín-González
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| | - Antonio G Ravelo-García
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
- Interactive Technologies Institute (ITI/LARSyS and ARDITI), 9020-105 Funchal, Portugal
| | - Juan L Navarro-Mesa
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| | - Eduardo Hernández-Pérez
- Institute for Technological Development and Innovation in Communications, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
| |
Collapse
|
2
|
Le VL, Kim D, Cho E, Jang H, Reyes RD, Kim H, Lee D, Yoon IY, Hong J, Kim JW. Real-Time Detection of Sleep Apnea Based on Breathing Sounds and Prediction Reinforcement Using Home Noises: Algorithm Development and Validation. J Med Internet Res 2023; 25:e44818. [PMID: 36811943 PMCID: PMC9996414 DOI: 10.2196/44818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 12/29/2022] [Accepted: 01/11/2023] [Indexed: 02/24/2023] Open
Abstract
BACKGROUND Multinight monitoring can be helpful for the diagnosis and management of obstructive sleep apnea (OSA). For this purpose, it is necessary to be able to detect OSA in real time in a noisy home environment. Sound-based OSA assessment holds great potential since it can be integrated with smartphones to provide full noncontact monitoring of OSA at home. OBJECTIVE The purpose of this study is to develop a predictive model that can detect OSA in real time, even in a home environment where various noises exist. METHODS This study included 1018 polysomnography (PSG) audio data sets, 297 smartphone audio data sets synced with PSG, and a home noise data set containing 22,500 noises to train the model to predict breathing events, such as apneas and hypopneas, based on breathing sounds that occur during sleep. The whole breathing sound of each night was divided into 30-second epochs and labeled as "apnea," "hypopnea," or "no-event," and the home noises were used to make the model robust to a noisy home environment. The performance of the prediction model was assessed using epoch-by-epoch prediction accuracy and OSA severity classification based on the apnea-hypopnea index (AHI). RESULTS Epoch-by-epoch OSA event detection showed an accuracy of 86% and a macro F1-score of 0.75 for the 3-class OSA event detection task. The model had an accuracy of 92% for "no-event," 84% for "apnea," and 51% for "hypopnea." Most misclassifications were made for "hypopnea," with 15% and 34% of "hypopnea" being wrongly predicted as "apnea" and "no-event," respectively. The sensitivity and specificity of the OSA severity classification (AHI≥15) were 0.85 and 0.84, respectively. CONCLUSIONS Our study presents a real-time epoch-by-epoch OSA detector that works in a variety of noisy home environments. Based on this, additional research is needed to verify the usefulness of various multinight monitoring and real-time diagnostic technologies in the home environment.
Collapse
Affiliation(s)
| | | | | | - Hyeryung Jang
- Department of Artificial Intelligence, Dongguk University, Seoul, Republic of Korea
| | | | | | | | - In-Young Yoon
- Department of Psychiatry, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.,Seoul National University College of Medicine, Seoul, Republic of Korea
| | | | - Jeong-Whun Kim
- Seoul National University College of Medicine, Seoul, Republic of Korea.,Department of Otorhinolaryngology, Seoul National University Bundang Hospital, Seongnam-si, Republic of Korea
| |
Collapse
|
3
|
Chen J, Shen M, Ma W, Zheng W. A spatio-temporal learning-based model for sleep apnea detection using single-lead ECG signals. Front Neurosci 2022; 16:972581. [PMID: 35992920 PMCID: PMC9389170 DOI: 10.3389/fnins.2022.972581] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Accepted: 07/18/2022] [Indexed: 11/13/2022] Open
Abstract
Sleep apnea (SA) is a common chronic sleep breathing disorder, which would cause stroke, cognitive decline, cardiovascular disease, or even death. The SA symptoms often manifest as frequent breathing interruptions during sleep and most individuals with sleeping disorders are not aware of the SA events. Using a portable device with single-lead ECG signal is an effective way to help an individual to monitor their sleep conditions at home. However, the SA detection performance of ECG-based methods is still difficult to meet the clinical practice requirement. In this study, we propose an end-to-end spatio-temporal learning-based SA detection method, which consists of multiple spatio-temporal blocks. Each block has the identical architecture with a convolutional neural network (CNN) layer, a max-pooling layer, and a bi-gated recurrent unit (BiGRU) layer. This architecture with repeated spatio-temporal blocks can well capture the morphological spatial feature information as well as the temporal feature information from ECG signals. The proposed SA detection model was evaluated on the publicly available datasets of PhysioNet Apnea-ECG dataset (Apnea-ECG) and University College Dublin Sleep Apnea Database (UCDDB). Extensive experimental results show that our proposed SA model on both Apnea-ECG and UCDDB datasets achieves state-of-the-art results, which are obviously superior to existing ECG-based SA detection methods. It means that our proposed method has the potential to be deployed into a healthcare system to provide a sleep monitoring service, which can screen out SA population with high risk and help to take timely interventions to prevent serious consequences.
Collapse
Affiliation(s)
- Junyang Chen
- School of Computer Science, South China Normal University, Guangzhou, China
| | - Mengqi Shen
- Grado Department of Industrial and Systems Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, United States
| | - Wenjun Ma
- School of Computer Science, South China Normal University, Guangzhou, China
| | - Weiping Zheng
- School of Computer Science, South China Normal University, Guangzhou, China
- *Correspondence: Weiping Zheng
| |
Collapse
|
4
|
Iwasaki A, Fujiwara K, Nakayama C, Sumi Y, Kano M, Nagamoto T, Kadotani H. R-R interval-based sleep apnea screening by a recurrent neural network in a large clinical polysomnography dataset. Clin Neurophysiol 2022; 139:80-89. [DOI: 10.1016/j.clinph.2022.04.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 03/10/2022] [Accepted: 04/12/2022] [Indexed: 11/03/2022]
|
5
|
JeyaJothi ES, Anitha J, Rani S, Tiwari B. A Comprehensive Review: Computational Models for Obstructive Sleep Apnea Detection in Biomedical Applications. BIOMED RESEARCH INTERNATIONAL 2022; 2022:7242667. [PMID: 35224099 PMCID: PMC8866013 DOI: 10.1155/2022/7242667] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 12/22/2021] [Indexed: 02/06/2023]
Abstract
Obstructive sleep apnea (OSA) is a sleep disorder characterized by periodic episodes of partial or complete upper airway obstruction caused by narrowing or collapse of the pharyngeal airway despite ongoing breathing efforts during sleep. Fall in the blood oxygen saturation and cortical arousals are prompted by this reduction in the airflow which lasts for at least 10 seconds. Impaired labor performance, debilitated quality of life, excessive daytime sleepiness, high snoring, and tiredness even after a whole night's sleep are the primary symptoms of OSA. In due course, the long-standing contributions of OSA culminate in hypertension, arrhythmia, cerebrovascular disease, and heart failure. The traditional diagnostic approach of OSA is the laboratory-based polysomnography (PSG) overnight sleep study, which is a tedious and labor-intensive process that exaggerates the discomfort to the patient. With the advent of computer-aided diagnosis (CAD), automatic detection of OSA has gained increasing interest among researchers in the area of sleep disorders as it influences both diagnostic and therapeutic decisions. The research literature on sleep apnea published during the last decade has been surveyed, focusing on the varied screening approaches accustomed to identifying OSA events and the developmental knowledge offered by multiple contributors from the software perspective. The current study presents an overview of the pathophysiology of OSA, the detection methods, physiological signals related to OSA, the different preprocessing, feature extraction, feature selection, and classification techniques employed for the detection and classification of OSA. Consequently, the research challenges and research gaps in the diagnosis of OSA are identified, critically analyzed, and presented in the best possible light.
Collapse
Affiliation(s)
- E. Smily JeyaJothi
- Department of Biomedical Instrumentation Engineering, Avinashilingam Institute for Home Science and Higher Education for Women, Coimbatore 641108, India
| | - J. Anitha
- Department of Electronics and Communication Engineering, Karunya Institute of Technology and Sciences, Coimbatore 641114, India
| | - Shalli Rani
- Chitkara University Institute of Engineering and Technology, Chitkara University, Rajpura Punjab-140401, India
| | | |
Collapse
|
6
|
Weng P, Wei K, Chen T, Chen M, Liu G. Fuzzy Approximate Entropy of Extrema Based on Multiple Moving Averages as a Novel Approach in Obstructive Sleep Apnea Screening. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE 2022; 10:4901211. [PMID: 36247084 PMCID: PMC9564195 DOI: 10.1109/jtehm.2022.3197084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 06/17/2022] [Accepted: 07/25/2022] [Indexed: 11/29/2022]
Abstract
Objective: Obstructive sleep apnea (OSA) is a respiratory disease associated with autonomic nervous system dysfunction. As a novel method for analyzing OSA depending on heart rate variability, fuzzy approximate entropy of extrema based on multiple moving averages (Emma-fApEn) can effectively assess the sympathetic tension limits, thereby realizing a good performance in the disease severity screening. Method: Sixty 6-h electrocardiogram recordings (20 healthy, 16 mild/moderate OSA and 34 severe OSA) from the PhysioNet database were used in this study. The performances of minima of Emma-fApEn (fApEn-minima), maxima of Emma-fApEn (fApEn-maxima) and classic time-frequency domain indices for each recording were assessed by significance analysis, correlation analysis, parameter optimization and OSA screening. Results: fApEn-minima and fApEn-maxima had significant differences between the severe OSA group and the other two groups, while the mean value (Mean) and the ratio of low-frequency power and high-frequency power (LH) could significantly differentiate OSA recordings from healthy recordings. The correlation coefficient between fApEn-minima and apnea-hypopnea index was the highest (|R| = 0.705). Machine learning methods were used to evaluate the performances of the above four indices. Random forest (RF) achieved the highest accuracy of 96.67% in OSA screening and 91.67% in severe OSA screening, with a good balance in both. Conclusion: Emma-fApEn may be used as a simple preliminary detection tool to assess the severity of OSA prior to polysomnography analysis.
Collapse
Affiliation(s)
- Peiyu Weng
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Keming Wei
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Tian Chen
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Mingjing Chen
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| | - Guanzheng Liu
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
7
|
ECG and Heart Rate Variability in Sleep-Related Breathing Disorders. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1384:159-183. [PMID: 36217084 DOI: 10.1007/978-3-031-06413-5_10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Here we discuss the current perspectives of comprehensive heart rate variability (HRV) analysis in electrocardiogram (ECG) signals as a non-invasive and reliable measure to assess autonomic function in sleep-related breathing disorders (SDB). It is a tool of increasing interest as different facets of HRV can be implemented to screen and diagnose SDB, monitor treatment efficacy, and prognose adverse cardiovascular outcomes in patients with sleep apnea. In this context, the technical aspects, pathophysiological features, and clinical applications of HRV are discussed to explore its usefulness in better understanding SDB.
Collapse
|
8
|
Nassi TE, Ganglberger W, Sun H, Bucklin AA, Biswal S, van Putten MJAM, Thomas RJ, Westover MB. Automated Scoring of Respiratory Events in Sleep with a Single Effort Belt and Deep Neural Networks. IEEE Trans Biomed Eng 2021; 69:2094-2104. [PMID: 34928786 DOI: 10.1109/tbme.2021.3136753] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Automatic detection and analysis of respiratory events in sleep using a single respiratory effort belt and deep learning. METHODS Using 9,656 polysomnography recordings from the Massachusetts General Hospital (MGH), we trained a neural network (WaveNet) to detect obstructive apnea, central apnea, hypopnea and respiratory-effort related arousals. Performance evaluation included event-based analysis and apnea-hypopnea index (AHI) stratification. The model was further evaluated on a public dataset, the Sleep-Heart-Health-Study-1, containing 8,455 polysomnographic recordings. RESULTS For binary apnea event detection in the MGH dataset, the neural network obtained a sensitivity of 68%, a specificity of 98%, a precision of 65%, a F1-score of 67%, and an area under the curve for the receiver operating characteristics curve and precision-recall curve of 0.93 and 0.71, respectively. AHI prediction resulted in a mean difference of 0.417.8 and a r2 of 0.90. For the multiclass task, we obtained varying performances: 84% of all labeled central apneas were correctly classified, whereas this metric was 51% for obstructive apneas, 40% for respiratory effort related arousals and 23% for hypopneas. CONCLUSION Our fully automated method can detect respiratory events and assess the AHI accurately. Differentiation of event types is more difficult and may reflect in part the complexity of human respiratory output and some degree of arbitrariness in the criteria used during manual annotation. SIGNIFICANCE The current gold standard of diagnosing sleep-disordered breathing, using polysomnography and manual analysis, is time-consuming, expensive, and only applicable in dedicated clinical environments. Automated analysis using a single effort belt signal overcomes these limitations.
Collapse
|
9
|
Martín-Montero A, Gutiérrez-Tobal GC, Gozal D, Barroso-García V, Álvarez D, del Campo F, Kheirandish-Gozal L, Hornero R. Bispectral Analysis of Heart Rate Variability to Characterize and Help Diagnose Pediatric Sleep Apnea. ENTROPY (BASEL, SWITZERLAND) 2021; 23:1016. [PMID: 34441156 PMCID: PMC8394544 DOI: 10.3390/e23081016] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 07/28/2021] [Accepted: 08/03/2021] [Indexed: 12/28/2022]
Abstract
Pediatric obstructive sleep apnea (OSA) is a breathing disorder that alters heart rate variability (HRV) dynamics during sleep. HRV in children is commonly assessed through conventional spectral analysis. However, bispectral analysis provides both linearity and stationarity information and has not been applied to the assessment of HRV in pediatric OSA. Here, this work aimed to assess HRV using bispectral analysis in children with OSA for signal characterization and diagnostic purposes in two large pediatric databases (0-13 years). The first database (training set) was composed of 981 overnight ECG recordings obtained during polysomnography. The second database (test set) was a subset of the Childhood Adenotonsillectomy Trial database (757 children). We characterized three bispectral regions based on the classic HRV frequency ranges (very low frequency: 0-0.04 Hz; low frequency: 0.04-0.15 Hz; and high frequency: 0.15-0.40 Hz), as well as three OSA-specific frequency ranges obtained in recent studies (BW1: 0.001-0.005 Hz; BW2: 0.028-0.074 Hz; BWRes: a subject-adaptive respiratory region). In each region, up to 14 bispectral features were computed. The fast correlation-based filter was applied to the features obtained from the classic and OSA-specific regions, showing complementary information regarding OSA alterations in HRV. This information was then used to train multi-layer perceptron (MLP) neural networks aimed at automatically detecting pediatric OSA using three clinically defined severity classifiers. Both classic and OSA-specific MLP models showed high and similar accuracy (Acc) and areas under the receiver operating characteristic curve (AUCs) for moderate (classic regions: Acc = 81.0%, AUC = 0.774; OSA-specific regions: Acc = 81.0%, AUC = 0.791) and severe (classic regions: Acc = 91.7%, AUC = 0.847; OSA-specific regions: Acc = 89.3%, AUC = 0.841) OSA levels. Thus, the current findings highlight the usefulness of bispectral analysis on HRV to characterize and diagnose pediatric OSA.
Collapse
Affiliation(s)
- Adrián Martín-Montero
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
| | - Gonzalo C. Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| | - David Gozal
- Department of Child Health and the Child Health Research Institute, The University of Missouri School of Medicine, Columbia, MO 65212, USA; (D.G.); (L.K.-G.)
| | - Verónica Barroso-García
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| | - Daniel Álvarez
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| | - Félix del Campo
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
- Sleep-Ventilation Unit, Pneumology Service, Río Hortega University Hospital, 47012 Valladolid, Spain
| | - Leila Kheirandish-Gozal
- Department of Child Health and the Child Health Research Institute, The University of Missouri School of Medicine, Columbia, MO 65212, USA; (D.G.); (L.K.-G.)
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, 47002 Valladolid, Spain; (G.C.G.-T.); (V.B.-G.); (D.Á.); (F.d.C.); (R.H.)
- CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, 28029 Madrid, Spain
| |
Collapse
|
10
|
Martín-Montero A, Gutiérrez-Tobal GC, Kheirandish-Gozal L, Jiménez-García J, Álvarez D, del Campo F, Gozal D, Hornero R. Heart rate variability spectrum characteristics in children with sleep apnea. Pediatr Res 2021; 89:1771-1779. [PMID: 32927472 PMCID: PMC7956022 DOI: 10.1038/s41390-020-01138-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 08/04/2020] [Accepted: 08/10/2020] [Indexed: 01/04/2023]
Abstract
BACKGROUND Classic spectral analysis of heart rate variability (HRV) in pediatric sleep apnea-hypopnea syndrome (SAHS) traditionally evaluates the very low frequency (VLF: 0-0.04 Hz), low frequency (LF: 0.04-0.15 Hz), and high frequency (HF: 0.15-0.40 Hz) bands. However, specific SAHS-related frequency bands have not been explored. METHODS One thousand seven hundred and thirty-eight HRV overnight recordings from two pediatric databases (0-13 years) were evaluated. The first one (981 children) served as training set to define new HRV pediatric SAHS-related frequency bands. The associated relative power (RP) were computed in the test set, the Childhood Adenotonsillectomy Trial database (CHAT, 757 children). Their relationships with polysomnographic variables and diagnostic ability were assessed. RESULTS Two new specific spectral bands of pediatric SAHS within 0-0.15 Hz were related to duration of apneic events, number of awakenings, and wakefulness after sleep onset (WASO), while an adaptive individual-specific new band from HF was related to oxyhemoglobin desaturations, arousals, and WASO. Furthermore, these new spectral bands showed improved diagnostic ability than classic HRV. CONCLUSIONS Novel spectral bands provide improved characterization of pediatric SAHS. These findings may pioneer a better understanding of the effects of SAHS on cardiac function and potentially serve as detection biomarkers. IMPACT New specific heart rate variability (HRV) spectral bands are identified and characterized as potential biomarkers in pediatric sleep apnea. Spectral band BW1 (0.001-0.005 Hz) is related to macro sleep disruptions. Spectral band BW2 (0.028-0.074 Hz) is related to the duration of apneic events. An adaptive spectral band within the respiratory range, termed ABW3, is related to oxygen desaturations. The individual and collective diagnostic ability of these novel spectral bands outperforms classic HRV bands.
Collapse
Affiliation(s)
| | - Gonzalo C. Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain.,CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain
| | - Leila Kheirandish-Gozal
- Department of Child Health and The Child Health Research Institute, The University of Missouri School of Medicine, Columbia, Missouri
| | | | - Daniel Álvarez
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain.,CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain.,Sleep-Ventilation Unit, Pneumology Department, Río Hortega University Hospital, Valladolid, Spain
| | - Félix del Campo
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain.,CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain.,Sleep-Ventilation Unit, Pneumology Department, Río Hortega University Hospital, Valladolid, Spain
| | - David Gozal
- Department of Child Health and The Child Health Research Institute, The University of Missouri School of Medicine, Columbia, Missouri
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain.,CIBER-BBN, Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain
| |
Collapse
|
11
|
Álvarez D, Arroyo CA, de Frutos JF, Crespo A, Cerezo-Hernández A, Gutiérrez-Tobal GC, Vaquerizo-Villar F, Barroso-García V, Moreno F, Ruiz T, Hornero R, del Campo F. Assessment of Nocturnal Autonomic Cardiac Imbalance in Positional Obstructive Sleep Apnea. A Multiscale Nonlinear Approach. ENTROPY (BASEL, SWITZERLAND) 2020; 22:E1404. [PMID: 33322747 PMCID: PMC7764670 DOI: 10.3390/e22121404] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 12/07/2020] [Accepted: 12/09/2020] [Indexed: 12/24/2022]
Abstract
Positional obstructive sleep apnea (POSA) is a major phenotype of sleep apnea. Supine-predominant positional patients are frequently characterized by milder symptoms and less comorbidity due to a lower age, body mass index, and overall apnea-hypopnea index. However, the bradycardia-tachycardia pattern during apneic events is known to be more severe in the supine position, which could affect the cardiac regulation of positional patients. This study aims at characterizing nocturnal heart rate modulation in the presence of POSA in order to assess potential differences between positional and non-positional patients. Patients showing clinical symptoms of suffering from a sleep-related breathing disorder performed unsupervised portable polysomnography (PSG) and simultaneous nocturnal pulse oximetry (NPO) at home. Positional patients were identified according to the Amsterdam POSA classification (APOC) criteria. Pulse rate variability (PRV) recordings from the NPO readings were used to assess overnight cardiac modulation. Conventional cardiac indexes in the time and frequency domains were computed. Additionally, multiscale entropy (MSE) was used to investigate the nonlinear dynamics of the PRV recordings in POSA and non-POSA patients. A total of 129 patients (median age 56.0, interquartile range (IQR) 44.8-63.0 years, median body mass index (BMI) 27.7, IQR 26.0-31.3 kg/m2) were classified as POSA (37 APOC I, 77 APOC II, and 15 APOC III), while 104 subjects (median age 57.5, IQR 49.0-67.0 years, median BMI 29.8, IQR 26.6-34.7 kg/m2) comprised the non-POSA group. Overnight PRV recordings from positional patients showed significantly higher disorderliness than non-positional subjects in the smallest biological scales of the MSE profile (τ = 1: 0.25, IQR 0.20-0.31 vs. 0.22, IQR 0.18-0.27, p < 0.01) (τ = 2: 0.41, IQR 0.34-0.48 vs. 0.37, IQR 0.29-0.42, p < 0.01). According to our findings, nocturnal heart rate regulation is severely affected in POSA patients, suggesting increased cardiac imbalance due to predominant positional apneas.
Collapse
Affiliation(s)
- Daniel Álvarez
- Pneumology Department, Río Hortega University Hospital, 47012 Valladolid, Spain; (C.A.A.); (J.F.d.F.); (A.C.); (A.C.-H.); (F.M.); (T.R.)
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (G.C.G.-T.); (F.V.-V.); (V.B.-G.); (R.H.)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 47011 Valladolid, Spain
| | - C. Ainhoa Arroyo
- Pneumology Department, Río Hortega University Hospital, 47012 Valladolid, Spain; (C.A.A.); (J.F.d.F.); (A.C.); (A.C.-H.); (F.M.); (T.R.)
| | - Julio F. de Frutos
- Pneumology Department, Río Hortega University Hospital, 47012 Valladolid, Spain; (C.A.A.); (J.F.d.F.); (A.C.); (A.C.-H.); (F.M.); (T.R.)
| | - Andrea Crespo
- Pneumology Department, Río Hortega University Hospital, 47012 Valladolid, Spain; (C.A.A.); (J.F.d.F.); (A.C.); (A.C.-H.); (F.M.); (T.R.)
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (G.C.G.-T.); (F.V.-V.); (V.B.-G.); (R.H.)
| | - Ana Cerezo-Hernández
- Pneumology Department, Río Hortega University Hospital, 47012 Valladolid, Spain; (C.A.A.); (J.F.d.F.); (A.C.); (A.C.-H.); (F.M.); (T.R.)
| | - Gonzalo C. Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (G.C.G.-T.); (F.V.-V.); (V.B.-G.); (R.H.)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 47011 Valladolid, Spain
| | - Fernando Vaquerizo-Villar
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (G.C.G.-T.); (F.V.-V.); (V.B.-G.); (R.H.)
| | - Verónica Barroso-García
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (G.C.G.-T.); (F.V.-V.); (V.B.-G.); (R.H.)
| | - Fernando Moreno
- Pneumology Department, Río Hortega University Hospital, 47012 Valladolid, Spain; (C.A.A.); (J.F.d.F.); (A.C.); (A.C.-H.); (F.M.); (T.R.)
| | - Tomás Ruiz
- Pneumology Department, Río Hortega University Hospital, 47012 Valladolid, Spain; (C.A.A.); (J.F.d.F.); (A.C.); (A.C.-H.); (F.M.); (T.R.)
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (G.C.G.-T.); (F.V.-V.); (V.B.-G.); (R.H.)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 47011 Valladolid, Spain
| | - Félix del Campo
- Pneumology Department, Río Hortega University Hospital, 47012 Valladolid, Spain; (C.A.A.); (J.F.d.F.); (A.C.); (A.C.-H.); (F.M.); (T.R.)
- Biomedical Engineering Group, University of Valladolid, 47011 Valladolid, Spain; (G.C.G.-T.); (F.V.-V.); (V.B.-G.); (R.H.)
- Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), 47011 Valladolid, Spain
| |
Collapse
|
12
|
Papini GB, Fonseca P, van Gilst MM, van Dijk JP, Pevernagie DAA, Bergmans JWM, Vullings R, Overeem S. Estimation of the apnea-hypopnea index in a heterogeneous sleep-disordered population using optimised cardiovascular features. Sci Rep 2019; 9:17448. [PMID: 31772228 PMCID: PMC6879766 DOI: 10.1038/s41598-019-53403-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Accepted: 10/31/2019] [Indexed: 11/22/2022] Open
Abstract
Obstructive sleep apnea (OSA) is a highly prevalent sleep disorder, which results in daytime symptoms, a reduced quality of life as well as long-term negative health consequences. OSA diagnosis and severity rating is typically based on the apnea-hypopnea index (AHI) retrieved from overnight poly(somno)graphy. However, polysomnography is costly, obtrusive and not suitable for long-term recordings. Here, we present a method for unobtrusive estimation of the AHI using ECG-based features to detect OSA-related events. Moreover, adding ECG-based sleep/wake scoring yields a fully automatic method for AHI-estimation. Importantly, our algorithm was developed and validated on a combination of clinical datasets, including datasets selectively including OSA-pathology but also a heterogeneous, “real-world” clinical sleep disordered population (262 participants in the validation set). The algorithm provides a good representation of the current gold standard AHI (0.72 correlation, estimation error of 0.56 ± 14.74 events/h), and can also be employed as a screening tool for a large range of OSA severities (ROC AUC ≥ 0.86, Cohen’s kappa ≥ 0.53 and precision ≥70%). The method compares favourably to other OSA monitoring strategies, showing the feasibility of cardiovascular-based surrogates for sleep monitoring to evolve into clinically usable tools.
Collapse
Affiliation(s)
- Gabriele B Papini
- Eindhoven University of Technology, Dept. of Electrical Engineering, Eindhoven, 5612 AZ, The Netherlands. .,Philips Research, High Tech Campus, Eindhoven, 5656 AE, The Netherlands. .,Sleep Medicine Centre Kempenhaeghe, Heeze, 5591 VE, The Netherlands.
| | - Pedro Fonseca
- Eindhoven University of Technology, Dept. of Electrical Engineering, Eindhoven, 5612 AZ, The Netherlands.,Philips Research, High Tech Campus, Eindhoven, 5656 AE, The Netherlands
| | - Merel M van Gilst
- Eindhoven University of Technology, Dept. of Electrical Engineering, Eindhoven, 5612 AZ, The Netherlands.,Sleep Medicine Centre Kempenhaeghe, Heeze, 5591 VE, The Netherlands
| | - Johannes P van Dijk
- Eindhoven University of Technology, Dept. of Electrical Engineering, Eindhoven, 5612 AZ, The Netherlands.,Sleep Medicine Centre Kempenhaeghe, Heeze, 5591 VE, The Netherlands
| | | | - Jan W M Bergmans
- Eindhoven University of Technology, Dept. of Electrical Engineering, Eindhoven, 5612 AZ, The Netherlands.,Philips Research, High Tech Campus, Eindhoven, 5656 AE, The Netherlands
| | - Rik Vullings
- Eindhoven University of Technology, Dept. of Electrical Engineering, Eindhoven, 5612 AZ, The Netherlands
| | - Sebastiaan Overeem
- Eindhoven University of Technology, Dept. of Electrical Engineering, Eindhoven, 5612 AZ, The Netherlands.,Sleep Medicine Centre Kempenhaeghe, Heeze, 5591 VE, The Netherlands
| |
Collapse
|
13
|
Multiscale Entropy Analysis with Low-Dimensional Exhaustive Search for Detecting Heart Failure. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9173496] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Multiscale entropy (MSE) is widely used to analyze heartbeat signals. Even though cardiologists do not use MSE to diagnose heart failure at present, these studies are of importance and have potential clinical applications. In previous studies, MSE discrimination between old congestive heart failure (CHF) and healthy individuals has remained controversial. Few studies have been published on the discrimination between them, using only MSE with machine learning for automatic multidimensional analysis, with reported testing accuracies of less than 86%. In this study, we determined the optimal MSE scales for discrimination by using a low-dimensional exhaustive search along with three classifiers—linear discriminant analysis (LDA), support vector machine (SVM), and k-nearest neighbor (KNN). In younger people (<55 years), the results showed an accuracy of up to 95.5% with two optimal MSE scales (2D) and up to 97.7% with four optimal MSE scales (4D) in discriminating between young CHF and healthy participants. In older people (≥55 years), the discrimination accuracy reached 90.1% using LDA in 2D, SVM in 3D (three optimal MSE scales), and KNN in 5D (five optimal MSE scales). LDA with a 3D exhaustive search also achieved 94.4% accuracy in older people. Therefore, the results indicate that MSE analysis can differentiate between CHF and healthy individuals of any age.
Collapse
|
14
|
Shao S, Wang T, Song C, Chen X, Cui E, Zhao H. Obstructive Sleep Apnea Recognition Based on Multi-Bands Spectral Entropy Analysis of Short-Time Heart Rate Variability. ENTROPY 2019; 21:e21080812. [PMID: 33267526 PMCID: PMC7515341 DOI: 10.3390/e21080812] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2019] [Revised: 08/11/2019] [Accepted: 08/16/2019] [Indexed: 01/14/2023]
Abstract
Obstructive sleep apnea (OSA) syndrome is a common sleep disorder. As an alternative to polysomnography (PSG) for OSA screening, the current automatic OSA detection methods mainly concentrate on feature extraction and classifier selection based on physiological signals. It has been reported that OSA is, along with autonomic nervous system (ANS) dysfunction and heart rate variability (HRV), a useful tool for ANS assessment. Therefore, in this paper, eight novel indices of short-time HRV are extracted for OSA detection, which are based on the proposed multi-bands time-frequency spectrum entropy (MTFSE) method. In the MTFSE, firstly, the power spectrum of HRV is estimated by the Burg-AR model, and the time-frequency spectrum image (TFSI) is obtained. Secondly, according to the physiological significance of HRV, the TFSI is divided into multiple sub-bands according to frequency. Last but not least, by studying the Shannon entropy of different sub-bands and the relationships among them, the eight indices are obtained. In order to validate the performance of MTFSE-based indices, the Physionet Apnea-ECG database and K-nearest neighbor (KNN), support vector machine (SVM), and decision tree (DT) classification methods are used. The SVM classification method gets the highest classification accuracy, its average accuracy is 91.89%, the average sensitivity is 88.01%, and the average specificity is 93.98%. Undeniably, the MTFSE-based indices provide a novel idea for the screening of OSA disease.
Collapse
Affiliation(s)
- Shiliang Shao
- School of computer science and engineering, Northeastern University, Shenyang 110819, China
- State Key Laboratory of Robotics, Shenyang Institute of Automation Chinese Academy of Sciences, Shenyang 110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China
- Correspondence:
| | - Ting Wang
- State Key Laboratory of Robotics, Shenyang Institute of Automation Chinese Academy of Sciences, Shenyang 110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China
| | - Chunhe Song
- State Key Laboratory of Robotics, Shenyang Institute of Automation Chinese Academy of Sciences, Shenyang 110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China
| | - Xingchi Chen
- School of computer science and engineering, Northeastern University, Shenyang 110819, China
| | - Enuo Cui
- School of computer science and engineering, Northeastern University, Shenyang 110819, China
| | - Hai Zhao
- School of computer science and engineering, Northeastern University, Shenyang 110819, China
| |
Collapse
|
15
|
Álvarez D, Sánchez-Fernández A, Andrés-Blanco AM, Gutiérrez-Tobal GC, Vaquerizo-Villar F, Barroso-García V, Hornero R, del Campo F. Influence of Chronic Obstructive Pulmonary Disease and Moderate-To-Severe Sleep Apnoea in Overnight Cardiac Autonomic Modulation: Time, Frequency and Non-Linear Analyses. ENTROPY 2019; 21:e21040381. [PMID: 33267095 PMCID: PMC7514865 DOI: 10.3390/e21040381] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 04/02/2019] [Accepted: 04/05/2019] [Indexed: 11/25/2022]
Abstract
Chronic obstructive pulmonary disease (COPD) is one of the most prevalent lung diseases worldwide. COPD patients show major dysfunction in cardiac autonomic modulation due to sustained hypoxaemia, which has been significantly related to higher risk of cardiovascular disease. Obstructive sleep apnoea syndrome (OSAS) is a frequent comorbidity in COPD patients. It has been found that patients suffering from both COPD and OSAS simultaneously, the so-called overlap syndrome, have notably higher morbidity and mortality. Heart rate variability (HRV) has demonstrated to be useful to assess changes in autonomic functioning in different clinical conditions. However, there is still little scientific evidence on the magnitude of changes in cardiovascular dynamics elicited by the combined effect of both respiratory diseases, particularly during sleep, when apnoeic events occur. In this regard, we hypothesised that a non-linear analysis is able to provide further insight into long-term dynamics of overnight cardiovascular modulation. Accordingly, this study is aimed at assessing the usefulness of sample entropy (SampEn) to distinguish changes in overnight pulse rate variability (PRV) recordings among three patient groups while sleeping: COPD, moderate-to-severe OSAS, and overlap syndrome. In order to achieve this goal, a population composed of 297 patients were studied: 22 with COPD alone, 213 showing moderate-to-severe OSAS, and 62 with COPD and moderate-to-severe OSAS simultaneously (COPD+OSAS). Cardiovascular dynamics were analysed using pulse rate (PR) recordings from unattended pulse oximetry carried out at patients’ home. Conventional time- and frequency- domain analyses were performed to characterise sympathetic and parasympathetic activation of the nervous system, while SampEn was applied to quantify long-term changes in irregularity. Our analyses revealed that overnight PRV recordings from COPD+OSAS patients were significantly more irregular (higher SampEn) than those from patients with COPD alone (0.267 [0.210–0.407] vs. 0.212 [0.151–0.267]; p < 0.05) due to recurrent apnoeic events during the night. Similarly, COPD + OSAS patients also showed significantly higher irregularity in PRV during the night than subjects with OSAS alone (0.267 [0.210–0.407] vs. 0.241 [0.189–0.325]; p = 0.05), which suggests that the cumulative effect of both diseases increases disorganization of pulse rate while sleeping. On the other hand, no statistical significant differences were found between COPD and COPD + OSAS patients when traditional frequency bands (LF and HF) were analysed. We conclude that SampEn is able to properly quantify changes in overnight cardiovascular dynamics of patients with overlap syndrome, which could be useful to assess cardiovascular impairment in COPD patients due to the presence of concomitant OSAS.
Collapse
Affiliation(s)
- Daniel Álvarez
- Sleep-Ventilation Unit, Pneumology Service, Río Hortega University Hospital, c/ Dulzaina 2, 47012 Valladolid, Spain
- Biomedical Engineering Group, University of Valladolid, Paseo de Belén 15, 47011 Valladolid, Spain
- Correspondence: ; Tel.: +34-983-420400 (ext. 85776)
| | - Ana Sánchez-Fernández
- Sleep-Ventilation Unit, Pneumology Service, Río Hortega University Hospital, c/ Dulzaina 2, 47012 Valladolid, Spain
| | - Ana M. Andrés-Blanco
- Sleep-Ventilation Unit, Pneumology Service, Río Hortega University Hospital, c/ Dulzaina 2, 47012 Valladolid, Spain
| | | | | | - Verónica Barroso-García
- Biomedical Engineering Group, University of Valladolid, Paseo de Belén 15, 47011 Valladolid, Spain
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, Paseo de Belén 15, 47011 Valladolid, Spain
| | - Félix del Campo
- Sleep-Ventilation Unit, Pneumology Service, Río Hortega University Hospital, c/ Dulzaina 2, 47012 Valladolid, Spain
- Biomedical Engineering Group, University of Valladolid, Paseo de Belén 15, 47011 Valladolid, Spain
| |
Collapse
|
16
|
Mendonca F, Mostafa SS, Ravelo-Garcia AG, Morgado-Dias F, Penzel T. A Review of Obstructive Sleep Apnea Detection Approaches. IEEE J Biomed Health Inform 2019; 23:825-837. [DOI: 10.1109/jbhi.2018.2823265] [Citation(s) in RCA: 75] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
17
|
Gutierrez-Tobal GC, Alvarez D, Crespo A, del Campo F, Hornero R. Evaluation of Machine-Learning Approaches to Estimate Sleep Apnea Severity From At-Home Oximetry Recordings. IEEE J Biomed Health Inform 2019; 23:882-892. [DOI: 10.1109/jbhi.2018.2823384] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
18
|
Álvarez D, Crespo A, Vaquerizo-Villar F, Gutierrez-Tobal GC, Cerezo-Hernández A, Barroso-García V, Ansermino JM, Dumont GA, Hornero R, Del Campo F, Garde A. Symbolic dynamics to enhance diagnostic ability of portable oximetry from the phone oximeter in the detection of paediatric sleep apnoea. Physiol Meas 2018; 39:104002. [PMID: 30230476 DOI: 10.1088/1361-6579/aae2a8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE This study is aimed at assessing symbolic dynamics as a reliable technique to characterise complex fluctuations of portable oximetry in the context of automated detection of childhood obstructive sleep apnoea-hypopnoea syndrome (OSAHS). APPROACH Nocturnal oximetry signals from 142 children with suspected OSAHS were acquired using the Phone Oximeter: a portable device that integrates a pulse oximeter with a smartphone. An apnoea-hypopnoea index (AHI) ≥5 events/h from simultaneous in-lab polysomnography was used to confirm moderate-to-severe childhood OSAHS. Symbolic dynamics was used to parameterise non-linear changes in the overnight oximetry profile. Conventional indices, anthropometric measures, and time-domain linear statistics were also considered. Forward stepwise logistic regression was used to obtain an optimum feature subset. Logistic regression (LR) was used to identify children with moderate-to-severe OSAHS. MAIN RESULTS The histogram of 3-symbol words from symbolic dynamics showed significant differences (p <0.01) between children with AHI <5 events/h and moderate-to-severe patients (AHI ≥5 events/h). Words representing increasing oximetry values after apnoeic events (re-saturations) showed relevant diagnostic information. Regarding the performance of individual characterization approaches, the LR model composed of features from symbolic dynamics alone reached a maximum performance of 78.4% accuracy (65.2% sensitivity; 86.8% specificity) and 0.83 area under the ROC curve (AUC). The classification performance improved combining all features. The optimum model from feature selection achieved 83.3% accuracy (73.5% sensitivity; 89.5% specificity) and 0.89 AUC, significantly (p-value <0.01) outperforming the other models. SIGNIFICANCE Symbolic dynamics provides complementary information to conventional oximetry analysis enabling reliable detection of moderate-to-severe paediatric OSAHS from portable oximetry.
Collapse
Affiliation(s)
- Daniel Álvarez
- Pneumology Service, Rio Hortega University Hospital, Valladolid, Valladolid, SPAIN
| | - Andrea Crespo
- Pneumology Service, Rio Hortega University Hospital, Valladolid, Valladolid, SPAIN
| | - Fernado Vaquerizo-Villar
- Biomedical Engineering Group, ETSI Telecomunicación, Universidad de Valladolid, Valladolid, Castilla y León, SPAIN
| | - Gonzalo Cesar Gutierrez-Tobal
- Biomedical Engineering Group ETS Ingenieros de Telecommunicacion, Universidad de Valladolid, Camino del Cementerio sn, 47011 Valladoid, Valladolid, SPAIN
| | - Ana Cerezo-Hernández
- Pneumology Service, Rio Hortega University Hospital, Valladolid, Valladolid, SPAIN
| | - Verónica Barroso-García
- Biomedical Engineering Group, ETSI Telecomunicación, Universidad de Valladolid, Valladolid, Castilla y León, SPAIN
| | | | - Guy A Dumont
- University of British Columbia, Vancouver, British Columbia, CANADA
| | - Roberto Hornero
- Biomedical Engineering Group, ETSI Telecomunicación, Universidad de Valladolid, Valladolid, Castilla y León, SPAIN
| | - Felix Del Campo
- Pneumology Service, Rio Hortega University Hospital, Valladolid, Valladolid, SPAIN
| | - Ainara Garde
- Universiteit Twente, Enschede, 7500 AE, NETHERLANDS
| |
Collapse
|
19
|
Improving the understanding of sleep apnea characterization using Recurrence Quantification Analysis by defining overall acceptable values for the dimensionality of the system, the delay, and the distance threshold. PLoS One 2018; 13:e0194462. [PMID: 29621264 PMCID: PMC5886413 DOI: 10.1371/journal.pone.0194462] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Accepted: 03/02/2018] [Indexed: 11/25/2022] Open
Abstract
Our contribution focuses on the characterization of sleep apnea from a cardiac rate point of view, using Recurrence Quantification Analysis (RQA), based on a Heart Rate Variability (HRV) feature selection process. Three parameters are crucial in RQA: those related to the embedding process (dimension and delay) and the threshold distance. There are no overall accepted parameters for the study of HRV using RQA in sleep apnea. We focus on finding an overall acceptable combination, sweeping a range of values for each of them simultaneously. Together with the commonly used RQA measures, we include features related to recurrence times, and features originating in the complex network theory. To the best of our knowledge, no author has used them all for sleep apnea previously. The best performing feature subset is entered into a Linear Discriminant classifier. The best results in the “Apnea-ECG Physionet database” and the “HuGCDN2014 database” are, according to the area under the receiver operating characteristic curve, 0.93 (Accuracy: 86.33%) and 0.86 (Accuracy: 84.18%), respectively. Our system outperforms, using a relatively small set of features, previously existing studies in the context of sleep apnea. We conclude that working with dimensions around 7–8 and delays about 4–5, and using for the threshold distance the Fixed Amount of Nearest Neighbours (FAN) method with 5% of neighbours, yield the best results. Therefore, we would recommend these reference values for future work when applying RQA to the analysis of HRV in sleep apnea. We also conclude that, together with the commonly used vertical and diagonal RQA measures, there are newly used features that contribute valuable information for apnea minutes discrimination. Therefore, they are especially interesting for characterization purposes. Using two different databases supports that the conclusions reached are potentially generalizable, and are not limited by database variability.
Collapse
|
20
|
Heart rate variability feature selection in the presence of sleep apnea: An expert system for the characterization and detection of the disorder. Comput Biol Med 2017; 91:47-58. [DOI: 10.1016/j.compbiomed.2017.10.004] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 10/06/2017] [Accepted: 10/06/2017] [Indexed: 11/18/2022]
|
21
|
Irregularity and Variability Analysis of Airflow Recordings to Facilitate the Diagnosis of Paediatric Sleep Apnoea-Hypopnoea Syndrome. ENTROPY 2017. [DOI: 10.3390/e19090447] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
22
|
Shokoueinejad M, Fernandez C, Carroll E, Wang F, Levin J, Rusk S, Glattard N, Mulchrone A, Zhang X, Xie A, Teodorescu M, Dempsey J, Webster J. Sleep apnea: a review of diagnostic sensors, algorithms, and therapies. Physiol Meas 2017; 38:R204-R252. [PMID: 28820743 DOI: 10.1088/1361-6579/aa6ec6] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
While public awareness of sleep related disorders is growing, sleep apnea syndrome (SAS) remains a public health and economic challenge. Over the last two decades, extensive controlled epidemiologic research has clarified the incidence, risk factors including the obesity epidemic, and global prevalence of obstructive sleep apnea (OSA), as well as establishing a growing body of literature linking OSA with cardiovascular morbidity, mortality, metabolic dysregulation, and neurocognitive impairment. The US Institute of Medicine Committee on Sleep Medicine estimates that 50-70 million US adults have sleep or wakefulness disorders. Furthermore, the American Academy of Sleep Medicine (AASM) estimates that more than 29 million US adults suffer from moderate to severe OSA, with an estimated 80% of those individuals living unaware and undiagnosed, contributing to more than $149.6 billion in healthcare and other costs in 2015. Although various devices have been used to measure physiological signals, detect apneic events, and help treat sleep apnea, significant opportunities remain to improve the quality, efficiency, and affordability of sleep apnea care. As our understanding of respiratory and neurophysiological signals and sleep apnea physiological mechanisms continues to grow, and our ability to detect and process biomedical signals improves, novel diagnostic and treatment modalities emerge. OBJECTIVE This article reviews the current engineering approaches for the detection and treatment of sleep apnea. APPROACH It discusses signal acquisition and processing, highlights the current nonsurgical and nonpharmacological treatments, and discusses potential new therapeutic approaches. MAIN RESULTS This work has led to an array of validated signal and sensor modalities for acquiring, storing and viewing sleep data; a broad class of computational and signal processing approaches to detect and classify SAS disease patterns; and a set of distinctive therapeutic technologies whose use cases span the continuum of disease severity. SIGNIFICANCE This review provides a current perspective of the classes of tools at hand, along with a sense of their relative strengths and areas for further improvement.
Collapse
Affiliation(s)
- Mehdi Shokoueinejad
- Department of Biomedical Engineering, University of Wisconsin-Madison, 1550 Engineering Drive, Madison, WI 53706-1609, United States of America. Department of Population Health Sciences, University of Wisconsin-Madison, 610 Walnut St 707, Madison, WI 53726, United States of America. EnsoData Research, EnsoData Inc., 111 N Fairchild St, Suite 240, Madison, WI 53703, United States of America
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Multiscale Entropy Analysis of Unattended Oximetric Recordings to Assist in the Screening of Paediatric Sleep Apnoea at Home. ENTROPY 2017. [DOI: 10.3390/e19060284] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
24
|
Correntropy-Based Pulse Rate Variability Analysis in Children with Sleep Disordered Breathing. ENTROPY 2017. [DOI: 10.3390/e19060282] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
25
|
Measures of Morphological Complexity of Gray Matter on Magnetic Resonance Imaging for Control Age Grouping. ENTROPY 2015. [DOI: 10.3390/e17127868] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
26
|
Oxygen Saturation and RR Intervals Feature Selection for Sleep Apnea Detection. ENTROPY 2015. [DOI: 10.3390/e17052932] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|