1
|
Grégory V, Lou F, Arthur G, Pierre G, Costantino B. Impact of Five Weeks of Strengthening Under Blood Flow Restriction (BFR) or Supplemental Oxygen Breathing (Normobaric Hyperoxia) on the Medial Gastrocnemius. J Funct Morphol Kinesiol 2024; 9:258. [PMID: 39728242 DOI: 10.3390/jfmk9040258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2024] [Revised: 11/28/2024] [Accepted: 12/03/2024] [Indexed: 12/28/2024] Open
Abstract
Background and Objectives: This study investigates the effects of a five-week training program on the medial gastrocnemius muscle, comparing two approaches: blood flow restriction (BFR) training and normobaric hyperoxia (oxygen supplementation). It evaluates three strengthening modalities (dynamic, isometric, and the 3/7 method) analyzing their impact on maximal voluntary contraction (MVC), muscle architecture, and perceived exertion. Methods: A total of 36 young healthy participants (21 females, 15 males) were randomized into six subgroups (n = 6 each) based on the type of contraction and oxygen condition. Training sessions (three per week) were conducted for five weeks at 30% of MVC. Measurements of MVC, muscle circumference, pennation angle, fascicle length, and perceived exertion were taken at baseline (T0), mid-protocol (T1), and post-protocol (T2). Results: All groups demonstrated significant increases in MVC after five weeks, with no notable differences between BFR and oxygen conditions. Structural changes were observed in specific subgroups: the BFR-isometric group showed increased calf circumference (p < 0.05), and the 3/7 groups exhibited significant fascicle length gains (p < 0.05). Perceived exertion was consistently higher in BFR groups compared to oxygen supplementation, particularly in dynamic exercises. Conclusions: Both BFR and oxygen supplementation are effective in enhancing strength with light loads, though they elicit different structural and perceptual responses. Oxygen supplementation may be more comfortable and less strenuous, offering a viable alternative for populations unable to tolerate BFR. Future research should focus on optimizing training parameters and exploring applications tailored to specific athletic or clinical contexts.
Collapse
Affiliation(s)
- Vervloet Grégory
- Environmental, Occupational, Aging (Integrative) Physiology Laboratory, Haute Ecole Bruxelles-Brabant (HE2B), 1160 Brussels, Belgium
| | - Fregosi Lou
- Environmental, Occupational, Aging (Integrative) Physiology Laboratory, Haute Ecole Bruxelles-Brabant (HE2B), 1160 Brussels, Belgium
| | - Gauthier Arthur
- Environmental, Occupational, Aging (Integrative) Physiology Laboratory, Haute Ecole Bruxelles-Brabant (HE2B), 1160 Brussels, Belgium
| | - Grenot Pierre
- Environmental, Occupational, Aging (Integrative) Physiology Laboratory, Haute Ecole Bruxelles-Brabant (HE2B), 1160 Brussels, Belgium
| | - Balestra Costantino
- Environmental, Occupational, Aging (Integrative) Physiology Laboratory, Haute Ecole Bruxelles-Brabant (HE2B), 1160 Brussels, Belgium
- Anatomical Research and Clinical Studies, Vrije Universiteit Brussels (VUB), 1090 Brussels, Belgium
- Motor Sciences Department, Physical Activity Teaching Unit, Université Libre de Bruxelles (ULB), 1050 Brussels, Belgium
- DAN Europe Research Division (Roseto-Brussels), 1160 Brussels, Belgium
| |
Collapse
|
2
|
Łuczak S, Ekwińska M, Tomaszewski D. A Method of Precise Auto-Calibration in a Micro-Electro-Mechanical System Accelerometer. SENSORS (BASEL, SWITZERLAND) 2024; 24:4018. [PMID: 38931800 PMCID: PMC11207480 DOI: 10.3390/s24124018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 06/08/2024] [Accepted: 06/11/2024] [Indexed: 06/28/2024]
Abstract
A novel design of a MEMS (Micro-Electromechanical System) capacitive accelerometer fabricated by surface micromachining, with a structure enabling precise auto-calibration during operation, is presented. Precise auto-calibration was introduced to ensure more accurate acceleration measurements compared to standard designs. The standard mechanical structure of the accelerometer (seismic mass integrated with elastic suspension and movable plates coupled with fixed plates forming a system of differential sensing capacitors) was equipped with three movable detection electrodes coupled with three fixed electrodes, thus creating three atypical tunneling displacement transducers detecting three specific positions of seismic mass with high precision, enabling the auto-calibration of the accelerometer while it was being operated. Auto-calibration is carried out by recording the accelerometer indication while the seismic mass occupies a specific position, which corresponds to a known value of acting acceleration determined in a pre-calibration process. The diagram and the design of the mechanical structure of the accelerometer, the block diagram of the electronic circuits, and the mathematical relationships used for auto-calibration are presented. The results of the simulation studies related to mechanical and electric phenomena are discussed.
Collapse
Affiliation(s)
- Sergiusz Łuczak
- Warsaw University of Technology, Faculty of Mechatronics, 00-661 Warsaw, Poland
| | - Magdalena Ekwińska
- Łukasiewicz Research Network Institute of Microelectronics and Photonics, Al. Lotnikow 32/46, 02-668 Warsaw, Poland; (M.E.); (D.T.)
| | - Daniel Tomaszewski
- Łukasiewicz Research Network Institute of Microelectronics and Photonics, Al. Lotnikow 32/46, 02-668 Warsaw, Poland; (M.E.); (D.T.)
| |
Collapse
|
3
|
Keklicek H, Selcuk H, Yilmaz A. Fatigue of the intrinsic foot core muscles had a greater effect on gait than extrinsic foot core muscles: A time-series based analyze. Foot (Edinb) 2024; 59:102088. [PMID: 38522258 DOI: 10.1016/j.foot.2024.102088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Accepted: 03/10/2024] [Indexed: 03/26/2024]
Abstract
BACKGROUND The Heel Rise endurance (HRE) which indicates the extrinsic foot core (ECO) muscle's performance and the paper grip endurance (PGE) which indicates the intrinsic foot core (ICO) muscle's performance are essential components of a healthy foot function. However, the foot core muscles' fatigue response on spatial and temporal gait parameters after the HRE and the PGE tests were not adequately investigated. The purpose of this study was to determine whether the fatigue of the ICO and the ECO muscles affect gait parameters. MATERIAL AND METHODS A prospective, cross-sectional study was conducted on 22 sedentary individuals (44 feet). Gait was investigated pre and after the Heel Rise (HR) endurance test and the paper grip (PG) endurance test by inertial sensors. At least 500 consecutive steps were collected for each individual. Spatial-temporal gait parameters were used as outcome measures. RESULTS ECO fatigue and ICO fatigue led to increases in the step length (p < 0.05) and the stride lengths (p < 0.05), the single support (p < 0.05), and the terminal stance durations (p < 0.05). It was also seen that ICO fatigue had a greater effect on gait than ECO fatigue. The ECO fatigue had a medium to large effect on the gait parameters (d=0.313-0.646). The ICO fatigue affected gait with a large effect (d=0.524-2.048). CONCLUSION The ECO fatigue and the ICO fatigue led to clinically important changes in long-range gait parameters and the ICO fatigue had a greater effect on gait than ECO fatigue. It was suggested that clinicians add ICO muscle endurance training to improve the physical performance of individuals.
Collapse
Affiliation(s)
- Hilal Keklicek
- Trakya Unversity, Faculty of Health Sciences Department of Physiotherapy and Rehabilitation, Edirne, Turkey.
| | - Halit Selcuk
- Trakya Unversity, Faculty of Health Sciences Department of Physiotherapy and Rehabilitation, Edirne, Turkey
| | - Ali Yilmaz
- Trakya Unversity, Faculty of Medicine Department of Anatomy, Edirne, Turkey
| |
Collapse
|
4
|
Szabo DA, Neagu N, Teodorescu S, Apostu M, Predescu C, Pârvu C, Veres C. The Role and Importance of Using Sensor-Based Devices in Medical Rehabilitation: A Literature Review on the New Therapeutic Approaches. SENSORS (BASEL, SWITZERLAND) 2023; 23:8950. [PMID: 37960649 PMCID: PMC10648494 DOI: 10.3390/s23218950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 10/22/2023] [Accepted: 10/31/2023] [Indexed: 11/15/2023]
Abstract
Due to the growth of sensor technology, more affordable integrated circuits, and connectivity technologies, the usage of wearable equipment and sensing devices for monitoring physical activities, whether for wellness, sports monitoring, or medical rehabilitation, has exploded. The current literature review was performed between October 2022 and February 2023 using PubMed, Web of Science, and Scopus in accordance with P.R.I.S.M.A. criteria. The screening phase resulted in the exclusion of 69 articles that did not fit the themes developed in all subchapters of the study, 41 articles that dealt exclusively with rehabilitation and orthopaedics, 28 articles whose abstracts were not visible, and 10 articles that dealt exclusively with other sensor-based devices and not medical ones; the inclusion phase resulted in the inclusion of 111 articles. Patients who utilise sensor-based devices have several advantages due to rehabilitating a missing component, which marks the accomplishment of a fundamental goal within the rehabilitation program. As technology moves faster and faster forward, the field of medical rehabilitation has to adapt to the time we live in by using technology and intelligent devices. This means changing every part of rehabilitation and finding the most valuable and helpful gadgets that can be used to regain lost functions, keep people healthy, or prevent diseases.
Collapse
Affiliation(s)
- Dan Alexandru Szabo
- Department of Human Movement Sciences, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania;
- Department ME1, Faculty of Medicine in English, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Nicolae Neagu
- Department of Human Movement Sciences, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania;
| | - Silvia Teodorescu
- Department of Doctoral Studies, National University of Physical Education and Sports, 060057 Bucharest, Romania;
| | - Mihaela Apostu
- Department of Special Motor and Rehabilitation Medicine, National University of Physical Education and Sports, 060057 Bucharest, Romania; (M.A.); (C.P.)
| | - Corina Predescu
- Department of Special Motor and Rehabilitation Medicine, National University of Physical Education and Sports, 060057 Bucharest, Romania; (M.A.); (C.P.)
| | - Carmen Pârvu
- Faculty of Physical Education and Sports, “Dunărea de Jos” University, 63-65 Gării Street, 337347 Galati, Romania;
| | - Cristina Veres
- Department of Industrial Engineering and Management, University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania;
| |
Collapse
|
5
|
Kim J, Kang S, Kim SJ. A smart insole system capable of identifying proper heel raise posture for chronic ankle instability rehabilitation. Sci Rep 2022; 12:10796. [PMID: 35750787 PMCID: PMC9232603 DOI: 10.1038/s41598-022-14313-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 06/06/2022] [Indexed: 11/18/2022] Open
Abstract
Heel raise is widely prescribed to patients with chronic ankle instability in order to strengthen the Peroneus Longus muscle (PL) which supports the weakened lateral collateral ligaments. While the exercise itself is intuitive, ankle orientation is of particular importance because heel raises performed with inversion do not well recruit the PL. This implies that proper execution is imperative and a means to assess heel raise training sessions is needed. In this study we present a smart insole system capable of identifying heel raise events and its corresponding rise, hold and drop phases, which allows for a more descriptive analysis. The results from our heel raise sessions, which consist of four different variants performed by five healthy subjects, suggest that medial–lateral foot pressure distribution and foot orientation are needed to differentiate heel raises performed with ankle eversion and inversion. We go further and substantiate that proper execution, detected by our system, indeed leads to increased PL activation by analyzing the electromyography signals. We believe that the proposed system may provide clinicians with invaluable information regarding onsite as well as at-home training and possibly, with biofeedback, serve as foundation for software as a medical device.
Collapse
Affiliation(s)
- Jaewook Kim
- Department of Biomedical Engineering, Korea University College of Medicine, Seoul, 02841, South Korea
| | - Seonghyun Kang
- Department of Biomedical Engineering, Korea University College of Medicine, Seoul, 02841, South Korea
| | - Seung-Jong Kim
- Department of Biomedical Engineering, Korea University College of Medicine, Seoul, 02841, South Korea.
| |
Collapse
|
6
|
Pimenta L, Garcia NM, Zdravevski E, Chorbev I, Trajkovik V, Lameski P, Albuquerque C, Pires IM. Can the Eight Hop Test Be Measured with Sensors? A Systematic Review. SENSORS 2022; 22:s22093582. [PMID: 35591272 PMCID: PMC9105795 DOI: 10.3390/s22093582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 05/04/2022] [Accepted: 05/06/2022] [Indexed: 02/01/2023]
Abstract
Rehabilitation aims to increase the independence and physical function after injury, surgery, or other trauma, so that patients can recover to their previous ability as much as possible. To be able to measure the degree of recovery and impact of the treatment, various functional performance tests are used. The Eight Hop Test is a hop exercise that is directly linked to the rehabilitation of people suffering from tendon and ligament injuries on the lower limb. This paper presents a systematic review on the use of sensors for measuring functional movements during the execution of the Eight Hop Test, focusing primarily on the use of sensors, related diseases, and different methods implemented. Firstly, an automated search was performed on the publication databases: PubMed, Springer, ACM, IEEE Xplore, MDPI, and Elsevier. Secondly, the publications related to the Eight-Hop Test and sensors were filtered according to several search criteria and 15 papers were finally selected to be analyzed in detail. Our analysis found that the Eight Hop Test measurements can be performed with motion, force, and imaging sensors.
Collapse
Affiliation(s)
- Luís Pimenta
- Escola de Ciências e Tecnologia, University of Trás-os-Montes e Alto Douro, Quinta de Prados, 5001-801 Vila Real, Portugal;
| | - Nuno M. Garcia
- Instituto de Telecomunicações, Universidade da Beira Interior, 6200-001 Covilhã, Portugal;
| | - Eftim Zdravevski
- Faculty of Computer Science and Engineering, University Ss Cyril and Methodius, 1000 Skopje, North Macedonia; (E.Z.); (I.C.); (V.T.); (P.L.)
| | - Ivan Chorbev
- Faculty of Computer Science and Engineering, University Ss Cyril and Methodius, 1000 Skopje, North Macedonia; (E.Z.); (I.C.); (V.T.); (P.L.)
| | - Vladimir Trajkovik
- Faculty of Computer Science and Engineering, University Ss Cyril and Methodius, 1000 Skopje, North Macedonia; (E.Z.); (I.C.); (V.T.); (P.L.)
| | - Petre Lameski
- Faculty of Computer Science and Engineering, University Ss Cyril and Methodius, 1000 Skopje, North Macedonia; (E.Z.); (I.C.); (V.T.); (P.L.)
| | - Carlos Albuquerque
- Health Sciences Research Unit: Nursing (UICISA: E), Nursing School of Coimbra (ESEnfC), 3046-851 Coimbra, Portugal;
- Higher School of Health, Polytechnic Institute of Viseu, 3504-510 Viseu, Portugal
- Child Studies Research Center (CIEC), University of Minho, 4710-057 Braga, Portugal
| | - Ivan Miguel Pires
- Escola de Ciências e Tecnologia, University of Trás-os-Montes e Alto Douro, Quinta de Prados, 5001-801 Vila Real, Portugal;
- Instituto de Telecomunicações, Universidade da Beira Interior, 6200-001 Covilhã, Portugal;
- Correspondence: ; Tel.: +351-966-379-785
| |
Collapse
|
7
|
Abstract
At present, diverse, innovative technology is used in electronics and ubiquitous computing environments [...]
Collapse
|
8
|
Abstract
The wide-spread use of wearables and the adoption of the Internet of Things (IoT) paradigm provide an opportunity to use mobile-device sensors for medical applications. Sensors available in the commonly used devices may inspire innovative solutions for physiotherapy striving for accurate and early identification of various pathologies. An essential and reliable performance measure is the ten-meter walk test, which is employed to determine functional mobility, gait, and vestibular function. Sensor-based approaches can identify the various test phases and their segmented duration, among other parameters. The measurement parameter primarily used is related to the tests’ duration, and after identifying patterns, a variety of physical treatments can be recommended. This paper reviews multiple studies focusing on automated measurements of the ten-meter walk test with different sensors. Most of the analyzed studies measure similar parameters as traditional methods, such as velocity, duration, and other involuntary and dangerous patients’ movements after stroke. That provides an opportunity to measure different parameters that can be later fed into machine learning models for analyzing more complex patterns.
Collapse
|
9
|
Hoffmann R, Brodowski H, Steinhage A, Grzegorzek M. Detecting Walking Challenges in Gait Patterns Using a Capacitive Sensor Floor and Recurrent Neural Networks. SENSORS 2021; 21:s21041086. [PMID: 33562548 PMCID: PMC7914733 DOI: 10.3390/s21041086] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/21/2021] [Accepted: 01/30/2021] [Indexed: 11/16/2022]
Abstract
Gait patterns are a result of the complex kinematics that enable human two-legged locomotion, and they can reveal a lot about a person’s state and health. Analysing them is useful for researchers to get new insights into the course of diseases, and for physicians to track the progress after healing from injuries. When a person walks and is interfered with in any way, the resulting disturbance can show up and be found in the gait patterns. This paper describes an experimental setup for capturing gait patterns with a capacitive sensor floor, which can detect the time and position of foot contacts on the floor. With this setup, a dataset was recorded where 42 participants walked over a sensor floor in different modes, inter alia, normal pace, closed eyes, and dual-task. A recurrent neural network based on Long Short-Term Memory units was trained and evaluated for the classification task of recognising the walking mode solely from the floor sensor data. Furthermore, participants were asked to do the Unilateral Heel-Rise Test, and their gait was recorded before and after doing the test. Another neural network instance was trained to predict the number of repetitions participants were able to do on the test. As the results of the classification tasks turned out to be promising, the combination of this sensor floor and the recurrent neural network architecture seems like a good system for further investigation leading to applications in health and care.
Collapse
Affiliation(s)
- Raoul Hoffmann
- SensProtect GmbH, 85635 Höhenkirchen-Siegertsbrunn, Germany;
- Institute of Medical Informatics, University of Lübeck, 23538 Lübeck, Germany;
- Correspondence:
| | - Hanna Brodowski
- Institute of Health Sciences, Department of Physiotherapy, Pain and Exercise Research Lübeck (P.E.R.L.), University of Lübeck, 23538 Lübeck, Germany;
- Geriatrics Research Group, Charité-Universitätsmedizin Berlin, 13347 Berlin, Germany
| | - Axel Steinhage
- SensProtect GmbH, 85635 Höhenkirchen-Siegertsbrunn, Germany;
| | - Marcin Grzegorzek
- Institute of Medical Informatics, University of Lübeck, 23538 Lübeck, Germany;
| |
Collapse
|