1
|
Zhang C, Yang Y, Qin D, Hu R, Hu L. Silver nanocluster-based ratiometric fluorescence sensors for X-ray dose detection. Talanta 2024; 271:125631. [PMID: 38241924 DOI: 10.1016/j.talanta.2024.125631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 12/28/2023] [Accepted: 01/04/2024] [Indexed: 01/21/2024]
Abstract
In this paper, we synthesized silver nanoclusters using bovine serum albumin (BSA) as a template (BSA@AgNCs). Then, we anchored hydroxyphenyl fluorescein (HPF) to yield HPF-BSA@AgNCs. When exposed to X-rays, hydroxyl (∙OH) radicals generated by radiolysis of water react with HPF to produce fluorescein, which emits enhanced fluorescence at 515 nm (λex = 480 nm). The fluorescence intensity of BSA@AgNCs at 685 nm (λex = 480 nm) remains stable when exposed to X-rays. This HPF-BSA@AgNCs ratiometric fluorescence sensor can rapidly detect 0.1-20 Gy (the energy deposited per unit mass, J/kg) of X-rays. In addition, HPF-BSA@AgNCs exhibit good durability and temperature stability. Finally, HPF-BSA@AgNCs were used to measure the absorbed doses of A549 cells and evaluate the cell irradiation damage.
Collapse
Affiliation(s)
- Chengfang Zhang
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou, China
| | - Yuanyuan Yang
- Department of Oncology, Dushu Lake Hospital Affiliated to Soochow University, Suzhou, China
| | - Danni Qin
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou, China
| | - Rui Hu
- Department of Radiation Oncology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Suzhou, China.
| | - Liang Hu
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, and School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou, China.
| |
Collapse
|
2
|
Kudrevicius L, Jaselskė E, Stankus G, Arslonova S, Adliene D. Post-Irradiation Behavior of Colored PVA-Based Films Containing Ag Nanoparticles as Radiation Detectors/Exposure Indicators. Gels 2024; 10:290. [PMID: 38786207 PMCID: PMC11121668 DOI: 10.3390/gels10050290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 04/18/2024] [Accepted: 04/22/2024] [Indexed: 05/25/2024] Open
Abstract
Ionizing radiation covers a broad spectrum of applications. Since radioactive/radiation pollution is directly related to radiation risk, radiation levels should be strictly controlled. Different detection methods can be applied for radiation registration and monitoring. In this paper, radiation-induced variations in the optical properties of silver-enriched PVA-based hydrogel films with and without azo dye (Toluidine blue O, TBO, and Methyl red, MR) additives were investigated, and the feasibility of these free-standing films to serve as radiation detectors/exposure indicators was assessed. AgNO3 admixed with PVA gel was used as a source for the radiation-induced synthesis of silver nanoparticles (AgNPs) in irradiated gel films. Three types of sensors were prepared: silver-enriched PVA films containing a small amount of glycerol (AgPVAGly); silver-enriched PVA films with toluidine blue adducts (AgPVAGlyTBO); and silver-enriched PVA films with methyl red additives (AgPVAGlyMR). The selection of TBO and MR was based on their sensitivity to irradiation. The irradiation of the samples was performed in TrueBeam2.1 (VARIAN) using 6 MeV photons. Different doses up to 10 Gy were delivered to the films. The sensitivity of the films was assessed by analyzing the characteristic UV-Vis absorbance peaks on the same day as irradiation and 7, 30, 45, 90, and 180 days after irradiation. It was found that the addition of azo dyes led to an enhanced radiation sensitivity of the AgNPs containing films (0.6 Gy-1 for AgPVAGlyTBO and 0.4 Gy-1 for AgPVAGlyMR) irradiated with <2 Gy doses, indicating their applicability as low-dose exposure indicators. The irradiated films were less sensitive to higher doses. Almost no dose fading was detected between the 7th and 45th day after irradiation. Based on the obtained results, competing AgNP formation and color-bleaching effects in the AgPVAGly films with dye additives are discussed.
Collapse
Affiliation(s)
- Linas Kudrevicius
- Physics Department, Kaunas University of Technology, 51368 Kaunas, Lithuania;
| | - Evelina Jaselskė
- Neurosurgery Department, Lithuanian University of Health Sciences, 44307 Kaunas, Lithuania
| | - Gabrielius Stankus
- Physics Department, Kaunas University of Technology, 51368 Kaunas, Lithuania;
| | - Shirin Arslonova
- Tashkent City Branch of Republican Specialized Scientific-Practical Medical Centre of Oncology and Radiology, Boguston Str. 1, Tashkent P.O. Box 100070, Uzbekistan
| | - Diana Adliene
- Physics Department, Kaunas University of Technology, 51368 Kaunas, Lithuania;
| |
Collapse
|
3
|
Nicolucci P, Gambaro G, Araujo Silva KM, Souza Lima I, Baffa O, Pasquarelli A. XMEA: A New Hybrid Diamond Multielectrode Array for the In Situ Assessment of the Radiation Dose Enhancement by Nanoparticles. SENSORS (BASEL, SWITZERLAND) 2024; 24:2409. [PMID: 38676026 PMCID: PMC11053603 DOI: 10.3390/s24082409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 04/06/2024] [Accepted: 04/08/2024] [Indexed: 04/28/2024]
Abstract
This work presents a novel multielectrode array (MEA) to quantitatively assess the dose enhancement factor (DEF) produced in a medium by embedded nanoparticles. The MEA has 16 nanocrystalline diamond electrodes (in a cell-culture well), and a single-crystal diamond divided into four quadrants for X-ray dosimetry. DEF was assessed in water solutions with up to a 1000 µg/mL concentration of silver, platinum, and gold nanoparticles. The X-ray detectors showed a linear response to radiation dose (r2 ≥ 0.9999). Overall, platinum and gold nanoparticles produced a dose enhancement in the medium (maximum of 1.9 and 3.1, respectively), while silver nanoparticles produced a shielding effect (maximum of 37%), lowering the dose in the medium. This work shows that the novel MEA can be a useful tool in the quantitative assessment of radiation dose enhancement due to nanoparticles. Together with its suitability for cells' exocytosis studies, it proves to be a highly versatile device for several applications.
Collapse
Affiliation(s)
- Patricia Nicolucci
- Department of Physics, Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-901, Brazil; (P.N.); (I.S.L.); (O.B.)
| | - Guilherme Gambaro
- Department of Physics, Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-901, Brazil; (P.N.); (I.S.L.); (O.B.)
| | - Kyssylla Monnyelle Araujo Silva
- Department of Physics, Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-901, Brazil; (P.N.); (I.S.L.); (O.B.)
| | - Iara Souza Lima
- Department of Physics, Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-901, Brazil; (P.N.); (I.S.L.); (O.B.)
| | - Oswaldo Baffa
- Department of Physics, Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto 14040-901, Brazil; (P.N.); (I.S.L.); (O.B.)
| | - Alberto Pasquarelli
- Institute of Electron Devices and Circuits, University of Ulm, 89069 Ulm, Germany
| |
Collapse
|
4
|
Locarno S, Arosio P, Curtoni F, Piazzoni M, Pignoli E, Gallo S. Microscopic and Macroscopic Characterization of Hydrogels Based on Poly(vinyl-alcohol)-Glutaraldehyde Mixtures for Fricke Gel Dosimetry. Gels 2024; 10:172. [PMID: 38534590 DOI: 10.3390/gels10030172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/21/2024] [Accepted: 02/22/2024] [Indexed: 03/28/2024] Open
Abstract
In recent decades, hydrogels have emerged as innovative soft materials with widespread applications in the medical and biomedical fields, including drug delivery, tissue engineering, and gel dosimetry. In this work, a comprehensive study of the macroscopic and microscopic properties of hydrogel matrices based on Poly(vinyl-alcohol) (PVA) chemically crosslinked with Glutaraldehyde (GTA) was reported. Five different kinds of PVAs differing in molecular weight and degree of hydrolysis were considered. The local microscopic organization of the hydrogels was studied through the use of the 1H nuclear magnetic resonance relaxometry technique. Various macroscopic properties (gel fraction, water loss, contact angle, swelling degree, viscosity, and Young's Modulus) were investigated with the aim of finding a correlation between them and the features of the hydrogel matrix. Additionally, an optical characterization was performed on all the hydrogels loaded with Fricke solution to assess their dosimetric behavior. The results obtained indicate that the degree of PVA hydrolysis is a crucial parameter influencing the structure of the hydrogel matrix. This factor should be considered for ensuring stability over time, a vital property in the context of potential biomedical applications where hydrogels act as radiological tissue-equivalent materials.
Collapse
Affiliation(s)
- Silvia Locarno
- Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Via G. Celoria 16, 20133 Milano, Italy
| | - Paolo Arosio
- Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Consorzio Interuniversitario Nazionale per la Scienza e Tecnologia dei Materiali (INSTM), 20133 Milano, Italy
| | - Francesca Curtoni
- Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Via G. Celoria 16, 20133 Milano, Italy
| | - Marco Piazzoni
- Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Via G. Celoria 16, 20133 Milano, Italy
| | - Emanuele Pignoli
- Fondazione IRCCS "Istituto Nazionale dei Tumori", Via G. Venezian 1, 20133 Milano, Italy
| | - Salvatore Gallo
- Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Consorzio Interuniversitario Nazionale per la Scienza e Tecnologia dei Materiali (INSTM), 20133 Milano, Italy
| |
Collapse
|
5
|
Gerken LRH, Gerdes ME, Pruschy M, Herrmann IK. Prospects of nanoparticle-based radioenhancement for radiotherapy. MATERIALS HORIZONS 2023; 10:4059-4082. [PMID: 37555747 PMCID: PMC10544071 DOI: 10.1039/d3mh00265a] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 08/02/2023] [Indexed: 08/10/2023]
Abstract
Radiotherapy is a key pillar of solid cancer treatment. Despite a high level of conformal dose deposition, radiotherapy is limited due to co-irradiation of organs at risk and subsequent normal tissue toxicities. Nanotechnology offers an attractive opportunity for increasing the efficacy and safety of cancer radiotherapy. Leveraging the freedom of design and the growing synthetic capabilities of the nanomaterial-community, a variety of engineered nanomaterials have been designed and investigated as radiosensitizers or radioenhancers. While research so far has been primarily focused on gold nanoparticles and other high atomic number materials to increase the absorption cross section of tumor tissue, recent studies are challenging the traditional concept of high-Z nanoparticle radioenhancers and highlight the importance of catalytic activity. This review provides a concise overview on the knowledge of nanoparticle radioenhancement mechanisms and their quantification. It critically discusses potential radioenhancer candidate materials and general design criteria for different radiation therapy modalities, and concludes with research priorities in order to advance the development of nanomaterials, to enhance the efficacy of radiotherapy and to increase at the same time the therapeutic window.
Collapse
Affiliation(s)
- Lukas R H Gerken
- Nanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, 8092 Zurich, Switzerland.
- Particles-Biology Interactions Laboratory, Department of Materials Meet Life, Swiss Federal Laboratories for Materials Science and Technology (Empa), Lerchenfeldstrasse 5, 9014 St. Gallen, Switzerland
| | - Maren E Gerdes
- Karolinska Institutet, Solnavägen 1, 171 77 Stockholm, Sweden
| | - Martin Pruschy
- Laboratory for Applied Radiobiology, Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Winterthurerstrasse 190, 8057, Zurich, Switzerland
| | - Inge K Herrmann
- Nanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, 8092 Zurich, Switzerland.
- Particles-Biology Interactions Laboratory, Department of Materials Meet Life, Swiss Federal Laboratories for Materials Science and Technology (Empa), Lerchenfeldstrasse 5, 9014 St. Gallen, Switzerland
| |
Collapse
|
6
|
Qin D, Han Y, Hu L. Enhanced X-ray Dose Response of Radio-fluorescent Hydrogels Enabled by Persulfate Salts. J Fluoresc 2023; 33:2015-2021. [PMID: 36964847 PMCID: PMC10039678 DOI: 10.1007/s10895-023-03205-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Accepted: 03/08/2023] [Indexed: 03/26/2023]
Abstract
Coumarin 3-carboxylic acid (CCA)-loaded radio-fluorescent hydrogels have attracted interest for ionizing radiation dosimeters, but their sensitivity needs to be improved. In this study, we added ammonium persulfate (APS) to a polyacrylamide (PAAm)-CCA hydrogel. The introduction of APS improved the hydrogel dose sensitivity to 336.02 Gy- 1, which is 1.8 times that of the counterpart without APS. Our hydrogel can measure the X-ray dose in a range of 0 - 15 Gy with a lower limit of detection (LOD) of 0.1 Gy. Additionally, the hydrogel can sense X-ray doses within a wide range of the dose rate and temperature, and the dose‒response can be well retained 7 days postirradiation. Therefore, we think this study provides a simple and robust method to improve the sensitivity of CCA hydrogel dosimeters, presenting great potential in clinical radiotherapy.
Collapse
Affiliation(s)
- Danni Qin
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, School for Radiological and Interdisciplinary Sciences (RAD-X), Suzhou Medical College of Soochow University, Soochow University, Suzhou, China
| | - Yaqi Han
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, School for Radiological and Interdisciplinary Sciences (RAD-X), Suzhou Medical College of Soochow University, Soochow University, Suzhou, China
| | - Liang Hu
- State Key Laboratory of Radiation Medicine and Protection, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, School for Radiological and Interdisciplinary Sciences (RAD-X), Suzhou Medical College of Soochow University, Soochow University, Suzhou, China.
| |
Collapse
|
7
|
Gallo S, Locarno S. Gel Dosimetry. Gels 2023; 9:gels9040311. [PMID: 37102923 PMCID: PMC10138228 DOI: 10.3390/gels9040311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 04/02/2023] [Indexed: 04/28/2023] Open
Abstract
The purpose of radiation therapy (RT) is to cover tumor tissue homogeneously with a planned dose while minimizing the dose to the surrounding healthy tissue [...].
Collapse
Affiliation(s)
- Salvatore Gallo
- Dipartimento di Fisica "Aldo Pontremoli", Università di Milano, 20133 Milano, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, 20133 Milano, Italy
| | - Silvia Locarno
- Dipartimento di Fisica "Aldo Pontremoli", Università di Milano, 20133 Milano, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, 20133 Milano, Italy
| |
Collapse
|
8
|
Investigation of Colored Film Indicators for the Assessment of the Occasional Radiation Exposure. Gels 2023; 9:gels9030189. [PMID: 36975638 PMCID: PMC10048619 DOI: 10.3390/gels9030189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 02/26/2023] [Accepted: 02/27/2023] [Indexed: 03/05/2023] Open
Abstract
Occupational radiation exposure monitoring is well-established in clinical or industrial environments with various different dosimeter systems. Despite the availability of many dosimetry methods and devices, a challenge with the occasional exposure registration, which may occur due to the spilling of radioactive materials or splitting of these materials in the environment, still exists, because not every individual will have an appropriate dosimeter at the time of the irradiation event. The aim of this work was to develop radiation-sensitive films—color-changing radiation indicators, which can be attached to or integrated in the textile. Polyvinyl alcohol (PVA)-based polymer hydrogels were used as a basis for fabrication of radiation indicator films. Several organic dyes (brilliant carmosine (BC), brilliant scarlet (BS), methylene red (MR), brilliant green (BG), brilliant blue (BB), methylene blue (MB) and xylenol orange (XiO)) were used as a coloring additives. Moreover, PVA films enriched with Ag nanoparticles (PVA-Ag) were investigated. In order to assess the radiation sensitivity of the produced films, experimental samples were irradiated in a linear accelerator with 6 MeV X-ray photons and the radiation sensitivity of irradiated films was evaluated using UV–Vis spectrophotometry method. The most sensitive were PVA-BB films indicating 0.4 Gy−1 sensitivity in low-dose (0–1 or 2 Gy) range. The sensitivity at higher doses was modest. These PVA-dye films were sensitive enough to detect doses up to 10 Gy and PVA-MR film indicated stable 33.3% decolorization after irradiation at this dose. It was found that the dose sensitivity of all PVA-Ag gel films varied from 0.068 to 0.11 Gy−1 and was dependent on the Ag additives concentration. Exchange of a small amount of water with ethanol or isopropanol caused the enhancement of radiation sensitivity in the films with the lowest AgNO3 concentration. Radiation-induced color change of AgPVA films varied between 30 and 40%. Performed research demonstrated the potential of colored hydrogel films in their applications as indicators for the assessment of the occasional radiation exposure.
Collapse
|
9
|
Optical characterization of Fricke-methylthymol blue hydrogel dosimeter with gellan gum as physical cross-linker. J Radioanal Nucl Chem 2023. [DOI: 10.1007/s10967-023-08832-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2023]
|
10
|
Chelu M, Musuc AM. Polymer Gels: Classification and Recent Developments in Biomedical Applications. Gels 2023; 9:gels9020161. [PMID: 36826331 PMCID: PMC9956074 DOI: 10.3390/gels9020161] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 02/12/2023] [Accepted: 02/15/2023] [Indexed: 02/19/2023] Open
Abstract
Polymer gels are a valuable class of polymeric materials that have recently attracted significant interest due to the exceptional properties such as versatility, soft-structure, flexibility and stimuli-responsive, biodegradability, and biocompatibility. Based on their properties, polymer gels can be used in a wide range of applications: food industry, agriculture, biomedical, and biosensors. The utilization of polymer gels in different medical and industrial applications requires a better understanding of the formation process, the factors which affect the gel's stability, and the structure-rheological properties relationship. The present review aims to give an overview of the polymer gels, the classification of polymer gels' materials to highlight their important features, and the recent development in biomedical applications. Several perspectives on future advancement of polymer hydrogel are offered.
Collapse
|
11
|
Dong X, Tian Y, Wang F, Chen C, Wang Y, Ma J. Gold-Nanoparticle-Enhanced Radio-Fluorogenic Hydrogel Sensor for Low Radiation Doses in Clinical Radiotherapy. Polymers (Basel) 2022; 14:4841. [PMID: 36432968 PMCID: PMC9694710 DOI: 10.3390/polym14224841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 11/08/2022] [Indexed: 11/12/2022] Open
Abstract
Radio-fluorogenic hydrogel dosimeters are urgently needed in radiotherapy for 3D dose verification. However, few hydrogel sensors have been reported at low absorbed doses under 2 Gy which meets the requirements of clinical practice. Here, we report a new type of gold-nanoparticle-enhanced radio-fluorogenic agarose hydrogel with coumarin as the dose-responsive material. An optimal composition of 3 wt% of agarose, 0.1 mM of gold nanoparticles, and 0.5 mM coumarin was selected. The addition of gold nanoparticles enhanced the hydroxyl radicals generated from the radiolysis of water, which can react with coumarin and generate fluorescent 7-hydroxy-coumarin and, eventually, achieve low-dose verification of 0-2.4 Gy with a high linear correlation coefficient. These findings provide an effective method for 3D dose verification, and will inspire the development of other radio-fluorogenic sensing hydrogels as well.
Collapse
Affiliation(s)
| | | | | | | | - Yunlong Wang
- College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| | - Jun Ma
- College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
| |
Collapse
|
12
|
Tug-of-war between hydrogen bond and hydrophobic interaction of bisfunctionalized graphene oxide/hydrolyzed polyacrylamide allows thickening and salt-resistance in enhanced oil recovery. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.129909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
13
|
Chemical Overview of Gel Dosimetry Systems: A Comprehensive Review. Gels 2022; 8:gels8100663. [PMID: 36286165 PMCID: PMC9601373 DOI: 10.3390/gels8100663] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 10/10/2022] [Accepted: 10/12/2022] [Indexed: 11/17/2022] Open
Abstract
Advances in radiotherapy technology during the last 25 years have significantly improved both dose conformation to tumors and the preservation of healthy tissues, achieving almost real-time feedback by means of high-precision treatments and theranostics. Owing to this, developing high-performance systems capable of coping with the challenging requirements of modern ionizing radiation is a key issue to overcome the limitations of traditional dosimeters. In this regard, a deep understanding of the physicochemical basis of gel dosimetry, as one of the most promising tools for the evaluation of 3D high-spatial-resolution dose distributions, represents the starting point for developing new and innovative systems. This review aims to contribute thorough descriptions of the chemical processes and interactions that condition gel dosimetry outputs, often phenomenologically addressed, and particularly formulations reported since 2017.
Collapse
|
14
|
Rabaeh KA, Al-Zawaydaih HH, Eyadeh MM, Shatnawi MT. High optical stability of reusable radiochromic polyvinyl alcohol-iodine gel dosimeter for radiotherapy. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110338] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
15
|
De Deene Y. Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D. Gels 2022; 8:gels8090599. [PMID: 36135311 PMCID: PMC9498652 DOI: 10.3390/gels8090599] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/07/2022] [Accepted: 09/10/2022] [Indexed: 12/22/2022] Open
Abstract
Gel dosimetry was developed in the 1990s in response to a growing need for methods to validate the radiation dose distribution delivered to cancer patients receiving high-precision radiotherapy. Three different classes of gel dosimeters were developed and extensively studied. The first class of gel dosimeters is the Fricke gel dosimeters, which consist of a hydrogel with dissolved ferrous ions that oxidize upon exposure to ionizing radiation. The oxidation results in a change in the nuclear magnetic resonance (NMR) relaxation, which makes it possible to read out Fricke gel dosimeters by use of quantitative magnetic resonance imaging (MRI). The radiation-induced oxidation in Fricke gel dosimeters can also be visualized by adding an indicator such as xylenol orange. The second class of gel dosimeters is the radiochromic gel dosimeters, which also exhibit a color change upon irradiation but do not use a metal ion. These radiochromic gel dosimeters do not demonstrate a significant radiation-induced change in NMR properties. The third class is the polymer gel dosimeters, which contain vinyl monomers that polymerize upon irradiation. Polymer gel dosimeters are predominantly read out by quantitative MRI or X-ray CT. The accuracy of the dosimeters depends on both the physico-chemical properties of the gel dosimeters and on the readout technique. Many different gel formulations have been proposed and discussed in the scientific literature in the last three decades, and scanning methods have been optimized to achieve an acceptable accuracy for clinical dosimetry. More recently, with the introduction of the MR-Linac, which combines an MRI-scanner and a clinical linear accelerator in one, it was shown possible to acquire dose maps during radiation, but new challenges arise.
Collapse
Affiliation(s)
- Yves De Deene
- Liverpool & Macarthur Cancer Therapy Centres, Liverpool, NSW 1871, Australia; or
- Ingham Institute, Liverpool, NSW 2170, Australia
- School of Science, Western Sydney University, Penrith, NSW 2751, Australia
| |
Collapse
|