1
|
Stark BL, Gamboa M, Esparza A, Cavendar-Word TJ, Bermudez D, Carlon L, Roberson DA, Joddar B, Natividad-Diaz S. Materials Characterization of Stereolithography 3D Printed Polymer to Develop a Self-Driven Microfluidic Device for Bioanalytical Applications. ACS APPLIED BIO MATERIALS 2024. [PMID: 38776250 DOI: 10.1021/acsabm.4c00059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/24/2024]
Abstract
Stereolithography (SLA) 3D printing is a rapid prototyping technique and reproducible manufacturing platform, which makes it a useful tool to develop advanced microfluidic devices for bioanalytical applications. However, limited information exists regarding the physical, chemical, and biological properties of the photocured polymers printed with SLA. This study demonstrates the characterization of a commercially available SLA 3D printed polymer to evaluate the potential presence of any time-dependent changes in material properties that may affect its ability to produce functional, capillary-action microfluidic devices. The printed polymer was analyzed with Fourier transform infrared-attenuated total reflectance, contact angle measurements, tensile test, impact test, scanning electron microscopy, and fluid flow analysis. Polymer biocompatibility was assessed with propidium iodide flow cytometry and an MTT assay for cell viability. The material characterization and biocompatibility results were then implemented to design and fabricate a self-driven capillary action microfluidic device for future use as a bioanalytical assay. This study demonstrates temporally stable mechanical properties and biocompatibility of the SLA polymer. However, surface characterization through contact angle measurements shows the polymer's wettability changes over time which indicates there is a limited postprinting period when the polymer can be used for capillary-based fluid flow. Overall, this study demonstrates the feasibility of implementing SLA as a high-throughput manufacturing method for capillary action microfluidic devices.
Collapse
Affiliation(s)
- Britanny L Stark
- Department of Metallurgical, Materials, and Biomedical Engineering (MMBME), The University of Texas at El Paso (UTEP), 500 West University Avenue, El Paso, Texas 79968, United States
- 3D Printed Microphysiological Systems Laboratory, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - Michelle Gamboa
- Department of Metallurgical, Materials, and Biomedical Engineering (MMBME), The University of Texas at El Paso (UTEP), 500 West University Avenue, El Paso, Texas 79968, United States
- 3D Printed Microphysiological Systems Laboratory, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - Aibhlin Esparza
- Department of Metallurgical, Materials, and Biomedical Engineering (MMBME), The University of Texas at El Paso (UTEP), 500 West University Avenue, El Paso, Texas 79968, United States
- 3D Printed Microphysiological Systems Laboratory, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - Truman J Cavendar-Word
- Department of Metallurgical, Materials, and Biomedical Engineering (MMBME), The University of Texas at El Paso (UTEP), 500 West University Avenue, El Paso, Texas 79968, United States
- Polymer Extrusion Laboratory, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - Diego Bermudez
- Department of Metallurgical, Materials, and Biomedical Engineering (MMBME), The University of Texas at El Paso (UTEP), 500 West University Avenue, El Paso, Texas 79968, United States
- Polymer Extrusion Laboratory, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - Luisa Carlon
- Department of Metallurgical, Materials, and Biomedical Engineering (MMBME), The University of Texas at El Paso (UTEP), 500 West University Avenue, El Paso, Texas 79968, United States
- 3D Printed Microphysiological Systems Laboratory, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - David A Roberson
- Department of Metallurgical, Materials, and Biomedical Engineering (MMBME), The University of Texas at El Paso (UTEP), 500 West University Avenue, El Paso, Texas 79968, United States
- Polymer Extrusion Laboratory, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - Binata Joddar
- Department of Metallurgical, Materials, and Biomedical Engineering (MMBME), The University of Texas at El Paso (UTEP), 500 West University Avenue, El Paso, Texas 79968, United States
- Inspired Materials & Stem-Cell Based Tissue Engineering Laboratory (IMSTEL), The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
- Border Biomedical Research Center, University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| | - Sylvia Natividad-Diaz
- Department of Metallurgical, Materials, and Biomedical Engineering (MMBME), The University of Texas at El Paso (UTEP), 500 West University Avenue, El Paso, Texas 79968, United States
- 3D Printed Microphysiological Systems Laboratory, The University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
- Border Biomedical Research Center, University of Texas at El Paso, 500 West University Avenue, El Paso, Texas 79968, United States
| |
Collapse
|
2
|
Kunath BA, Beloglowka K, Rainbow R, Ploeg HL. Mechanical loading of ex vivo bovine trabecular bone in 3D printed bioreactor chambers. J Mech Behav Biomed Mater 2024; 153:106470. [PMID: 38422872 DOI: 10.1016/j.jmbbm.2024.106470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 02/05/2024] [Accepted: 02/16/2024] [Indexed: 03/02/2024]
Abstract
Previous ex vivo bone culture methods have successfully implemented polycarbonate (PC) bioreactors to investigate bone adaptation to mechanical load; however, they are difficult to fabricate and have been limited to a 5 mm maximum specimen height. The objective of this study was to validate a custom-made 3D printed MED610TM bioreactor system that addresses the limitations of the PC bioreactor and assess its efficacy in ex vivo bone culture. Twenty-three viable trabecular bone cores (10 mm height by 10 mm diameter) from an 18-month-old bovine sternum were cultured in MED610TM bioreactors with culture medium at 37 °C and 5% CO2 for 21-days. Bone cores were ranked based on their day 0 apparent elastic modulus (Eapp) and evenly separated into a "Load" group (n = 12) and a control group (n = 11). The Load group was loaded five times per week with a sinusoidal strain waveform between -1000 and -5000 με for 120 cycles at 2 Hz. Eapp was assessed on day 0, 8, and 21 using quasi-static tests with a -4000 με applied strain. Over 21-days, the Eapp of Load group samples tended to increase by more than double the control group (53.4% versus 20.9%) and no visual culture contamination was observed. This study demonstrated that bone organ culture in 3D printed MED610TM bioreactors replicated Eapp trends found in previous studies with PC bioreactors. However, further studies are warranted with a larger sample size to increase statistical power and histology to assess cell viability and bone mineral apposition rate.
Collapse
Affiliation(s)
- Brian A Kunath
- Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON, Canada; Centre for Health Innovation, Queen's University, Kingston, ON, Canada.
| | - Kail Beloglowka
- Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON, Canada; Centre for Health Innovation, Queen's University, Kingston, ON, Canada.
| | - Roshni Rainbow
- Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON, Canada; Centre for Health Innovation, Queen's University, Kingston, ON, Canada.
| | - Heidi-Lynn Ploeg
- Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON, Canada; Centre for Health Innovation, Queen's University, Kingston, ON, Canada.
| |
Collapse
|
3
|
Segeritz P, Kolesnik K, Scott DJ, Collins DJ. Quantitative mechanical stimulation of GPR68 using a novel 96 well flow plugin. LAB ON A CHIP 2024; 24:1616-1625. [PMID: 38288761 DOI: 10.1039/d3lc00767g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/13/2024]
Abstract
Mechanosensitive proteins play a crucial role in a range of physiological processes, including hearing, tactile sensation and regulating blood flow. While previous work has demonstrated the mechanosensitivity of several proteins, the ability to apply precisely defined mechanical forces to cells in a consistent, replicable manner remains a significant challenge. In this work we present a novel 96-well plate-compatible plugin device for generating highly-controlled flow-based mechanical simulation of cells, which enables quantitative assessment of mechanosensitive protein function. The device is used to mechanically stimulate HEK 293T cells expressing the mechanosensitive protein GPR68, a G protein-coupled receptor. By assaying intracellular calcium levels during flow-based cell stimulation, we determine that GPR68 signalling is a function of the applied shear-force. As this approach is compatible with conventional cell culture plates and allows for simultaneous readout in a conventional fluorescence plate reader, this represents a valuable new tool to investigate mechanotransduction.
Collapse
Affiliation(s)
- Philipp Segeritz
- Department of Biomedical Engineering, The University of Melbourne, Parkville, VIC 3010, Australia.
- The Florey Institute of Neuroscience and Mental Health, The University of Melbourne, 30 Royal Parade, Parkville, VIC 3052, Australia.
| | - Kirill Kolesnik
- Department of Biomedical Engineering, The University of Melbourne, Parkville, VIC 3010, Australia.
| | - Daniel J Scott
- The Florey Institute of Neuroscience and Mental Health, The University of Melbourne, 30 Royal Parade, Parkville, VIC 3052, Australia.
- Department of Biochemistry and Pharmacology, The University of Melbourne, Parkville, VIC 3010, Australia
| | - David J Collins
- Department of Biomedical Engineering, The University of Melbourne, Parkville, VIC 3010, Australia.
- The Graeme Clark Institute, The University of Melbourne, Parkville, VIC, 3010, Australia
| |
Collapse
|
4
|
Tanzli E, Kozior T, Hajnys J, Mesicek J, Brockhagen B, Grothe T, Ehrmann A. Improved cell growth on additively manufactured Ti64 substrates with varying porosity and nanofibrous coating. Heliyon 2024; 10:e25576. [PMID: 38356578 PMCID: PMC10865313 DOI: 10.1016/j.heliyon.2024.e25576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 01/25/2024] [Accepted: 01/30/2024] [Indexed: 02/16/2024] Open
Abstract
3T3 Swiss albino mouse cells are often used in biotechnological applications. These cells can grow adherently on suitable surfaces. In our study, they were grown on different titanium substrates, comparing commercially available titanium sheets of grade 1 and grade 2, respectively, with Ti64 which was 3D printed with different porosity in order to identify potential substitutes for common well-plates, which could - in case of 3D printed substrates - be produced in various shapes and dimensions and thus broaden the range of substrates for cell growth in biotechnology and tissue engineering. In addition, thin layers of poly(acrylonitrile) (PAN) nanofibers were electrospun on these substrates to add a nanostructure. The common titanium sheets showed lower cell cover factors than common well plates, which could not be improved by the thin nanofibrous coating. However, the Ti sheets with nanofiber mat coatings showed higher cell adhesion and proliferation than pure PAN nanofiber mats. The 3D printed Ti64 substrates prepared by laser metal fusion, on the other hand, enabled significantly higher proliferation of (66 ± 8)% cover factor after three days of cell growth than well plates which are usually applied as the gold standard for cell cultivation ((48 ± 11)% cover factor under identical conditions). Especially the Ti64 samples with higher porosity showed high cell adhesion and proliferation. Our study suggests investigating such porous Ti64 samples further as a potential future optimum for cell adhesion and proliferation.
Collapse
Affiliation(s)
- Ewin Tanzli
- Faculty of Engineering and Mathematics, Bielefeld University of Applied Sciences and Arts, 33619, Bielefeld, Germany
| | - Tomasz Kozior
- Faculty of Mechatronics and Mechanical Engineering, Kielce University of Technology, 25-314, Kielce, Poland
| | - Jiri Hajnys
- Department of Machining, Assembly and Engineering Metrology, Faculty of Mechanical Engineering, VSB – Technical University of Ostrava, 708 00, Ostrava Poruba, Czech Republic
| | - Jakub Mesicek
- Department of Machining, Assembly and Engineering Metrology, Faculty of Mechanical Engineering, VSB – Technical University of Ostrava, 708 00, Ostrava Poruba, Czech Republic
| | - Bennet Brockhagen
- Faculty of Engineering and Mathematics, Bielefeld University of Applied Sciences and Arts, 33619, Bielefeld, Germany
| | - Timo Grothe
- Faculty of Engineering and Mathematics, Bielefeld University of Applied Sciences and Arts, 33619, Bielefeld, Germany
| | - Andrea Ehrmann
- Faculty of Engineering and Mathematics, Bielefeld University of Applied Sciences and Arts, 33619, Bielefeld, Germany
| |
Collapse
|
5
|
Zhang X, Cheng F, Islam MR, Li H. The fabrication of the chitosan-based bioink for in vitro tissue repair and regeneration: A review. Int J Biol Macromol 2024; 257:128504. [PMID: 38040155 DOI: 10.1016/j.ijbiomac.2023.128504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 11/24/2023] [Accepted: 11/28/2023] [Indexed: 12/03/2023]
Abstract
The repair and regeneration of the injured tissues or organs is a major challenge for biomedicine, and the emerging 3D bioprinting technology as a class of promising techniques in biomedical research for the development of tissue engineering and regenerative medicine. Chitosan-based bioinks, as the natural biomaterials, are considered as ideal materials for 3D bioprinting to design and fabricate the various scaffold due to their unique dynamic reversibility and fantastic biological properties. Our review aims to provide an overview of chitosan-based bioinks for in vitro tissue repair and regeneration, starting from modification of chitosan that affect these bioprinting processes. In addition, we summarize the advances in chitosan-based bioinks used in the various 3D printing strategies. Moreover, the biomedical applications of chitosan-based bioinks are discussed, primarily centered on regenerative medicine and tissue modeling engineering. Finally, current challenges and future opportunities in this field are discussed. The combination of chitosan-based bioinks and 3D bioprinting will hold promise for developing novel biomedical scaffolds for tissue or organ repair and regeneration.
Collapse
Affiliation(s)
- Xiao Zhang
- School of Materials Science and Engineering, School of Chemistry and Chemical Engineering, MIIT Key Laboratory of Critical Materials Technology for New Energy Conversion and Storage, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China
| | - Feng Cheng
- School of Materials Science and Engineering, School of Chemistry and Chemical Engineering, MIIT Key Laboratory of Critical Materials Technology for New Energy Conversion and Storage, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China.
| | - Md Rashidul Islam
- College of Light Industry and Textile, Qiqihar University, Qiqihar, Heilongjiang 161000, PR China
| | - Hongbin Li
- School of Materials Science and Engineering, School of Chemistry and Chemical Engineering, MIIT Key Laboratory of Critical Materials Technology for New Energy Conversion and Storage, Harbin Institute of Technology, Harbin, Heilongjiang 150001, PR China; College of Light Industry and Textile, Qiqihar University, Qiqihar, Heilongjiang 161000, PR China.
| |
Collapse
|
6
|
Li JW, Chen HF, Huang PH, Kuo CFJ, Cheng CC, Chiu CW. Photocurable Carbon Nanotube/Polymer Nanocomposite for the 3D Printing of Flexible Capacitive Pressure Sensors. Polymers (Basel) 2023; 15:4706. [PMID: 38139958 PMCID: PMC10747156 DOI: 10.3390/polym15244706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 12/12/2023] [Accepted: 12/12/2023] [Indexed: 12/24/2023] Open
Abstract
A photocurable resin/carbon nanotube (CNT) nanocomposite was fabricated from aligned CNTs in an acrylic matrix. The conductivity of the nanocomposite increased rapidly and then stabilized when the CNT content was increased up to and beyond the percolation threshold. Various structures were created using a digital light processing (DLP) 3D printer. Various polymeric dispersants (SMA-amide) were designed and synthesized to improve the CNT dispersion and prevent aggregation. The benzene rings and lone electron pairs on the dispersant interacted with aromatic groups on the CNTs, causing the former to wrap around the latter. This created steric hindrance, thereby stabilizing and dispersing the CNTs in the solvent. CNT/polymer nanocomposites were created by combining the dispersant, CNTs, and a photocurable resin. The CNT content of the nanocomposite and the 3D printing parameters were tuned to optimize the conductivity and printing quality. A touch-based human interface device (HID) that utilizes the intrinsic conductivity of the nanocomposite and reliably detects touch signals was fabricated, enabling the free design of sensors of various styles and shapes using a low-cost 3D printer. The production of sensors without complex circuitry was achieved, enabling novel innovations.
Collapse
Affiliation(s)
- Jia-Wun Li
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
| | - Ho-Fu Chen
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
| | - Peng-Han Huang
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
| | - Chung-Feng Jeffrey Kuo
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
| | - Chih-Chia Cheng
- Graduate Institute of Applied Science and Technology, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
| | - Chih-Wei Chiu
- Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
| |
Collapse
|
7
|
Caparaso SM, Redwine AL, Wachs RA. Engineering a multicompartment in vitro model for dorsal root ganglia phenotypic assessment. J Biomed Mater Res B Appl Biomater 2023; 111:1903-1920. [PMID: 37326300 PMCID: PMC10527728 DOI: 10.1002/jbm.b.35294] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 05/19/2023] [Accepted: 05/31/2023] [Indexed: 06/17/2023]
Abstract
Despite the significant global prevalence of chronic pain, current methods to identify pain therapeutics often fail translation to the clinic. Phenotypic screening platforms rely on modeling and assessing key pathologies relevant to chronic pain, improving predictive capability. Patients with chronic pain often present with sensitization of primary sensory neurons (that extend from dorsal root ganglia [DRG]). During neuronal sensitization, painful nociceptors display lowered stimulation thresholds. To model neuronal excitability, it is necessary to maintain three key anatomical features of DRGs to have a physiologically relevant platform: (1) isolation between DRG cell bodies and neurons, (2) 3D platform to preserve cell-cell and cell-matrix interactions, and (3) presence of native non-neuronal support cells, including Schwann cells and satellite glial cells. Currently, no culture platforms maintain the three anatomical features of DRGs. Herein, we demonstrate an engineered 3D multicompartment device that isolates DRG cell bodies and neurites and maintains native support cells. We observed neurite growth into isolated compartments from the DRG using two formulations of collagen, hyaluronic acid, and laminin-based hydrogels. Further, we characterized the rheological, gelation and diffusivity properties of the two hydrogel formulations and found the mechanical properties mimic native neuronal tissue. Importantly, we successfully limited fluidic diffusion between the DRG and neurite compartment for up to 72 h, suggesting physiological relevance. Lastly, we developed a platform with the capability of phenotypic assessment of neuronal excitability using calcium imaging. Ultimately, our culture platform can screen neuronal excitability, providing a more translational and predictive system to identify novel pain therapeutics to treat chronic pain.
Collapse
Affiliation(s)
- Sydney M. Caparaso
- Department of Biological Systems Engineering, University of Nebraska-Lincoln, Lincoln Nebraska, USA
| | - Adan L. Redwine
- Department of Biological Systems Engineering, University of Nebraska-Lincoln, Lincoln Nebraska, USA
| | - Rebecca A. Wachs
- Department of Biological Systems Engineering, University of Nebraska-Lincoln, Lincoln Nebraska, USA
| |
Collapse
|
8
|
Wistner SC, Rashad L, Slaughter G. Advances in tissue engineering and biofabrication for in vitro skin modeling. BIOPRINTING (AMSTERDAM, NETHERLANDS) 2023; 35:e00306. [PMID: 38645432 PMCID: PMC11031264 DOI: 10.1016/j.bprint.2023.e00306] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
The global prevalence of skin disease and injury is continually increasing, yet conventional cell-based models used to study these conditions do not accurately reflect the complexity of human skin. The lack of inadequate in vitro modeling has resulted in reliance on animal-based models to test pharmaceuticals, biomedical devices, and industrial and environmental toxins to address clinical needs. These in vivo models are monetarily and morally expensive and are poor predictors of human tissue responses and clinical trial outcomes. The onset of three-dimensional (3D) culture techniques, such as cell-embedded and decellularized approaches, has offered accessible in vitro alternatives, using innovative scaffolds to improve cell-based models' structural and histological authenticity. However, these models lack adequate organizational control and complexity, resulting in variations between structures and the exclusion of physiologically relevant vascular and immunological features. Recently, biofabrication strategies, which combine biology, engineering, and manufacturing capabilities, have emerged as instrumental tools to recreate the heterogeneity of human skin precisely. Bioprinting uses computer-aided design (CAD) to yield robust and reproducible skin prototypes with unprecedented control over tissue design and assembly. As the interdisciplinary nature of biofabrication grows, we look to the promise of next-generation biofabrication technologies, such as organ-on-a-chip (OOAC) and 4D modeling, to simulate human tissue behaviors more reliably for research, pharmaceutical, and regenerative medicine purposes. This review aims to discuss the barriers to developing clinically relevant skin models, describe the evolution of skin-inspired in vitro structures, analyze the current approaches to biofabricating 3D human skin mimetics, and define the opportunities and challenges in biofabricating skin tissue for preclinical and clinical uses.
Collapse
Affiliation(s)
- Sarah C. Wistner
- Center for Bioelectronics, Old Dominion University, Norfolk, VA, 23508, USA
| | - Layla Rashad
- Center for Bioelectronics, Old Dominion University, Norfolk, VA, 23508, USA
| | - Gymama Slaughter
- Center for Bioelectronics, Old Dominion University, Norfolk, VA, 23508, USA
- Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, VA, 23508, USA
| |
Collapse
|
9
|
Rengarajan V, Clyde A, Pontsler J, Valiente J, Peel A, Huang Y. Assessing Leachable Cytotoxicity of 3D-Printed Polymers and Facile Detoxification Methods. 3D PRINTING AND ADDITIVE MANUFACTURING 2023; 10:1110-1121. [PMID: 37873063 PMCID: PMC10593418 DOI: 10.1089/3dp.2021.0216] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
Additive manufacturing of polymers is gaining momentum in health care industries by providing rapid 3D printing of customizable designs. Yet, little is explored about the cytotoxicity of leachable toxins that the 3D printing process introduced into the final product. We studied three printable materials, which have various mechanical properties and are widely used in stereolithography 3D printing. We evaluated the cytotoxicity of these materials through exposing two fibroblast cell lines (human and mouse derived) to the 3D-printed parts, using overlay indirect contact assays. All the 3D-printed parts were measured toxic to the cells in a leachable manner, with flexible materials more toxic than rigid materials. Furthermore, we attempted to reduce the toxicity of the 3D-printed material by employing three treatment methods (further curing, passivation coating, and Soxhlet solvent extraction). The Soxhlet solvent extraction method was the most effective in removing the leachable toxins, resulting in the eradication of the material's toxicity. Passivation coating and further curing showed moderate and little detoxification, respectively. Additionally, mechanical testing of the materials treated with extraction methods revealed no significant impacts on its mechanical performances. As leachable toxins are broadly present in 3D-printed polymers, our cytotoxicity evaluation and reduction methods could aid in extending the selections of biocompatible materials and pave the way for the translational use of 3D printing.
Collapse
Affiliation(s)
| | - Angela Clyde
- Department of Biological Engineering, Utah State University, Logan, Utah, USA
- Institute of Antiviral Research, Utah State University, Logan, Utah, USA
| | - Jefferson Pontsler
- Department of Biological Engineering, Utah State University, Logan, Utah, USA
| | - Jonathan Valiente
- Department of Biological Engineering, Utah State University, Logan, Utah, USA
| | - Adreann Peel
- Department of Biological Engineering, Utah State University, Logan, Utah, USA
| | - Yu Huang
- Department of Biological Engineering, Utah State University, Logan, Utah, USA
| |
Collapse
|
10
|
Musgrove HB, Saleheen A, Zatorski JM, Arneja A, Luckey CJ, Pompano RR. A Scalable, Modular Degasser for Passive In-Line Removal of Bubbles from Biomicrofluidic Devices. MICROMACHINES 2023; 14:435. [PMID: 36838135 PMCID: PMC9964747 DOI: 10.3390/mi14020435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/01/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
Bubbles are a common cause of microfluidic malfunction, as they can perturb the fluid flow within the micro-sized features of a device. Since gas bubbles form easily within warm cell culture reagents, degassing is often necessary for biomicrofluidic systems. However, fabrication of a microscale degasser that can be used modularly with pre-existing chips may be cumbersome or challenging, especially for labs not equipped for traditional microfabrication, and current commercial options can be expensive. Here, we address the need for an affordable, accessible bubble trap that can be used in-line for continuous perfusion of organs-on-chip and other microfluidic cultures. We converted a previously described, manually fabricated PDMS degasser to allow scaled up, reproducible manufacturing by commercial machining or fused deposition modeling (FDM) 3D printing. After optimization, the machined and 3D printed degassers were found to be stable for >2 weeks under constant perfusion, without leaks. With a ~140 µL chamber volume, trapping capacity was extrapolated to allow for ~5-20 weeks of degassing depending on the rate of bubble formation. The degassers were biocompatible for use with cell culture, and they successfully prevented bubbles from reaching a downstream microfluidic device. Both degasser materials showed little to no leaching. The machined degasser did not absorb reagents, while the FDM printed degasser absorbed a small amount, and both maintained fluidic integrity from 1 µL/min to >1 mL/min of pressure-driven flow. Thus, these degassers can be fabricated in bulk and allow for long-term, efficient bubble removal in a simple microfluidic perfusion set-up.
Collapse
Affiliation(s)
- Hannah B. Musgrove
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| | - Amirus Saleheen
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| | | | - Abhinav Arneja
- Department of Pathology, University of Virginia School of Medicine, Charlottesville, VA 22904, USA
| | - Chance John Luckey
- Department of Pathology, University of Virginia School of Medicine, Charlottesville, VA 22904, USA
| | - Rebecca R. Pompano
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| |
Collapse
|
11
|
Nam NE, Hwangbo NK, Jin G, Shim JS, Kim JE. Effects of heat-treatment methods on cytocompatibility and mechanical properties of dental products 3D-printed using photopolymerized resin. J Prosthodont Res 2023; 67:121-131. [PMID: 35570000 DOI: 10.2186/jpr.jpr_d_21_00345] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
PURPOSE The purpose of this study was to test heat-treatment methods for improving the cytocompatibility of dental 3D printable photopolymer resins. METHODS Nextdent C&B resin and a digital light processing 3D printer were used to print all specimens, which were divided into seven groups as follows: 1-month storage at controlled room temperature, 20 to 25 °C (RT), 24-hour storage at RT, 24-hour storage in RT water, 1-min immersion in 80 °C water, 1-min immersion in 100 °C water, 5-min immersion in 100 °C water, and autoclaving. Cell viability tests, cytotoxicity tests, and confocal laser scanning microscopy were performed to analyze the cytocompatibility of the 3D-printed resin. Fourier-transform infrared spectroscopy was performed after heat-treatment to determine the degree of conversion (DC). RESULTS Immersing printed resin samples in 100 °C water for 1 or 5 min after the curing process was an effective method for increasing cytocompatibility by inducing the preleaching of toxic substances such as unpolymerized monomers, photoinitiators, and additives. Moreover, the DC can be increased by additional polymerization without affecting the mechanical properties of the material. CONCLUSIONS Immersing the printed photosensitive dental resins in 100 °C water for 5 min is a suitable method for increasing cytocompatibility and the DC.
Collapse
Affiliation(s)
- Na-Eun Nam
- BK21 FOUR Project, Department of Prosthodontics, Yonsei University College of Dentistry, Korea
| | - Na-Kyung Hwangbo
- Department of Orofacial Pain and Oral Medicine, Yonsei University College of Dentistry, Korea
| | - Gan Jin
- Department of Prosthodontics, College of Dentistry, Yonsei University, Korea
| | - June-Sung Shim
- Department of Prosthodontics, College of Dentistry, Yonsei University, Korea
| | - Jong-Eun Kim
- Department of Prosthodontics, College of Dentistry, Yonsei University, Korea
| |
Collapse
|
12
|
Tailoring the composition of biocopolyester blends for dimensionally accurate extrusion-based printing, annealing and steam sterilization. Sci Rep 2022; 12:20341. [PMID: 36434090 PMCID: PMC9700831 DOI: 10.1038/s41598-022-24991-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 11/23/2022] [Indexed: 11/27/2022] Open
Abstract
Fused filament fabrication (FFF) represents a straightforward additive manufacturing technique applied in the medical sector for personalized patient treatment. However, frequently processed biopolymers lack sufficient thermal stability to be used as auxiliary devices such as surgical guides. The aim of this study was to evaluate the dimensional accuracy of experimental biocopolyester blends with improved thermal characteristics after printing, annealing and sterilization. A total of 160 square specimens and 40 surgical guides for oral implant placement were printed. One subgroup of each material (n = 10) underwent thermal annealing before both subgroups were subjected to steam sterilization (134 °C; 5 min). Specimens were digitized and the deviation from the original file was calculated. The thermal behavior was analyzed using differential scanning calorimetry and thermogravimetric analysis. A one-way ANOVA and t-tests were applied for statistical analyses (p < 0.05). All biocopolyester blends showed warpage during steam sterilization. However, the material modification with mineral fillers (21-32 wt%) and nucleating agents in combination with thermal annealing showed a significantly reduced warpage of printed square specimens. Geometry of the printing object seemed to affect dimensional accuracy, as printed surgical guides showed less distortion between the groups. In summary, biocopolyesters did benefit from fillers and annealing to improve their dimensional stability.
Collapse
|
13
|
Gharib G, Bütün İ, Muganlı Z, Kozalak G, Namlı İ, Sarraf SS, Ahmadi VE, Toyran E, van Wijnen AJ, Koşar A. Biomedical Applications of Microfluidic Devices: A Review. BIOSENSORS 2022; 12:bios12111023. [PMID: 36421141 PMCID: PMC9688231 DOI: 10.3390/bios12111023] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 10/30/2022] [Accepted: 11/08/2022] [Indexed: 05/26/2023]
Abstract
Both passive and active microfluidic chips are used in many biomedical and chemical applications to support fluid mixing, particle manipulations, and signal detection. Passive microfluidic devices are geometry-dependent, and their uses are rather limited. Active microfluidic devices include sensors or detectors that transduce chemical, biological, and physical changes into electrical or optical signals. Also, they are transduction devices that detect biological and chemical changes in biomedical applications, and they are highly versatile microfluidic tools for disease diagnosis and organ modeling. This review provides a comprehensive overview of the significant advances that have been made in the development of microfluidics devices. We will discuss the function of microfluidic devices as micromixers or as sorters of cells and substances (e.g., microfiltration, flow or displacement, and trapping). Microfluidic devices are fabricated using a range of techniques, including molding, etching, three-dimensional printing, and nanofabrication. Their broad utility lies in the detection of diagnostic biomarkers and organ-on-chip approaches that permit disease modeling in cancer, as well as uses in neurological, cardiovascular, hepatic, and pulmonary diseases. Biosensor applications allow for point-of-care testing, using assays based on enzymes, nanozymes, antibodies, or nucleic acids (DNA or RNA). An anticipated development in the field includes the optimization of techniques for the fabrication of microfluidic devices using biocompatible materials. These developments will increase biomedical versatility, reduce diagnostic costs, and accelerate diagnosis time of microfluidics technology.
Collapse
Affiliation(s)
- Ghazaleh Gharib
- Faculty of Engineering and Natural Science, Sabanci University, Istanbul 34956, Turkey
- Sabanci University Nanotechnology Research and Application Centre (SUNUM), Istanbul 34956, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano Diagnostics (EFSUN), Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul 34956, Turkey
| | - İsmail Bütün
- Faculty of Engineering and Natural Science, Sabanci University, Istanbul 34956, Turkey
| | - Zülâl Muganlı
- Faculty of Engineering and Natural Science, Sabanci University, Istanbul 34956, Turkey
| | - Gül Kozalak
- Faculty of Engineering and Natural Science, Sabanci University, Istanbul 34956, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano Diagnostics (EFSUN), Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul 34956, Turkey
| | - İlayda Namlı
- Faculty of Engineering and Natural Science, Sabanci University, Istanbul 34956, Turkey
| | | | | | - Erçil Toyran
- Faculty of Engineering and Natural Science, Sabanci University, Istanbul 34956, Turkey
| | - Andre J. van Wijnen
- Department of Biochemistry, University of Vermont, 89 Beaumont Avenue, Burlington, VT 05405, USA
| | - Ali Koşar
- Faculty of Engineering and Natural Science, Sabanci University, Istanbul 34956, Turkey
- Sabanci University Nanotechnology Research and Application Centre (SUNUM), Istanbul 34956, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano Diagnostics (EFSUN), Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul 34956, Turkey
- Turkish Academy of Sciences (TÜBA), Çankaya, Ankara 06700, Turkey
| |
Collapse
|
14
|
Mastrorocco A, Cacopardo L, Temerario L, Martino NA, Tridente F, Rizzo A, Lacalandra GM, Robbe D, Carluccio A, Dell’Aquila ME. Investigating and Modelling an Engineered Millifluidic In Vitro Oocyte Maturation System Reproducing the Physiological Ovary Environment in the Sheep Model. Cells 2022; 11:cells11223611. [PMID: 36429039 PMCID: PMC9688735 DOI: 10.3390/cells11223611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Revised: 11/04/2022] [Accepted: 11/12/2022] [Indexed: 11/18/2022] Open
Abstract
In conventional assisted reproductive technologies (ARTs), oocytes are in vitro cultured in static conditions. Instead, dynamic systems could better mimic the physiological in vivo environment. In this study, a millifluidic in vitro oocyte maturation (mIVM) system, in a transparent bioreactor integrated with 3D printed supports, was investigated and modeled thanks to computational fluid dynamic (CFD) and oxygen convection-reaction-diffusion (CRD) models. Cumulus-oocyte complexes (COCs) from slaughtered lambs were cultured for 24 h under static (controls) or dynamic IVM in absence (native) or presence of 3D-printed devices with different shapes and assembly modes, with/without alginate filling. Nuclear chromatin configuration, mitochondria distribution patterns, and activity of in vitro matured oocytes were assessed. The native dynamic mIVM significantly reduced the maturation rate compared to the static group (p < 0.001) and metaphase II (MII) oocytes showed impaired mitochondria distribution (p < 0.05) and activity (p < 0.001). When COCs were included in a combination of concave+ring support, particularly with alginate filling, oocyte maturation and mitochondria pattern were preserved, and bioenergetic/oxidative status was improved (p < 0.05) compared to controls. Results were supported by computational models demonstrating that, in mIVM in biocompatible inserts, COCs were protected from shear stresses while ensuring physiological oxygen diffusion replicating the one occurring in vivo from capillaries.
Collapse
Affiliation(s)
- Antonella Mastrorocco
- Department of Biosciences, Biotechnologies & Environment, University of Bari Aldo Moro, Via Edoardo Orabona, 70125 Bari, Italy
- Correspondence:
| | - Ludovica Cacopardo
- Research Centre E. Piaggio, University of Pisa, Largo Lucio Lazzarino 1, 56122 Pisa, Italy
| | - Letizia Temerario
- Department of Biosciences, Biotechnologies & Environment, University of Bari Aldo Moro, Via Edoardo Orabona, 70125 Bari, Italy
| | - Nicola Antonio Martino
- Department of Biosciences, Biotechnologies & Environment, University of Bari Aldo Moro, Via Edoardo Orabona, 70125 Bari, Italy
| | - Federico Tridente
- Department of Biosciences, Biotechnologies & Environment, University of Bari Aldo Moro, Via Edoardo Orabona, 70125 Bari, Italy
| | - Annalisa Rizzo
- Department of Veterinary Medicine, University of Bari Aldo Moro, Str. Prov. Casamassima Km. 3, 70010 Valenzano, Italy
| | - Giovanni Michele Lacalandra
- Department of Veterinary Medicine, University of Bari Aldo Moro, Str. Prov. Casamassima Km. 3, 70010 Valenzano, Italy
| | - Domenico Robbe
- Faculty of Veterinary Medicine, University of Teramo, Loc. Piano d’Accio, 64100 Teramo, Italy
| | - Augusto Carluccio
- Faculty of Veterinary Medicine, University of Teramo, Loc. Piano d’Accio, 64100 Teramo, Italy
| | - Maria Elena Dell’Aquila
- Department of Biosciences, Biotechnologies & Environment, University of Bari Aldo Moro, Via Edoardo Orabona, 70125 Bari, Italy
| |
Collapse
|
15
|
Zhao L, Wang X. 3D printed microfluidics for cell biological applications. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
16
|
Farid M, Mohamed F, Mehanna R, Abd-ellah M, Abdelrahman H. Cytotoxic assessment of 3D printed photoinitiated prosthodontic resins versus heat polymerized acrylic resin (In-Vitro Study).. [DOI: 10.21203/rs.3.rs-1948364/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Abstract
Background: Although 3D printed photoinitiated resins are among the many materials utilized in prosthetic appliances today, biocompatibility for photocuring 3D printing materials for direct and long-term contacting with living body remain scarce. The purpose of this in vitro study was to evaluate the cell viability of human gingival fibroblasts after the exposure to two different 3D printed photoinitiated resins and compare it to the traditionally used heat polymerized acrylic resin for up to 7 days.Methods: This comparative in vitro study of sample size (n= 96), where the 3D printed resin disc samples (n= 64), were divided into two test groups, test group 1 (TG1) for NextDent Base resin (n= 32) and test group 2 (TG2) for Dental LT clear resin (n= 32), to be compared to Heat polymerized acrylic resin samples (Reference group (RG)) (n= 32). Human gingival fibroblasts were extracted from attached keratinized gingival tissues collected from healthy patient undergoing clinical crown lengthening procedure, cellular viability using MTT assay in response to TG1, TG2 and RG samples was assessed throughout four-time intervals (24, 48, 72 and 168 hours). The One-Way ANOVA test followed by Tukey’s post hoc test and Repeated Measures ANOVA test were used for statistical analyses, statistically significant different at P value ≤ 0.05Results: Throughout time intervals, there was a decrease in cell viability of all groups but with favorable cell viability which was more that 90% denoting non cytotoxicity. It was found to be significant among RG (P< 0.0001). The highest cell viability was found after 24 hours among all groups; however, the least viability was found after 48 hours among TG1 and RG, and among TG2 after 72 hours. After 168 hours, there was a non-statistical significant change in cell viability between groups (P= 0.526). there was significant increase in optical density for all groups throughout time intervals (P< 0.0001).Conclusion: Photoinitiated resins are comparable to traditionally used heat polymerized acrylic resin with equivalent cytotoxic effect for long term use. 3D printed photoinitiated resins are biocompatible and suggested for long term intraoral use.
Collapse
Affiliation(s)
- Maisa Farid
- Prosthodontic Department, Faculty of Dentistry, Alexandria University
| | - Faten Mohamed
- Prosthodontic Department, Faculty of Dentistry, Alexandria University
| | - Radwa Mehanna
- Medical physiology Department, Faculty of Medicine, Alexandria University
| | - Mervat Abd-ELLAH
- Prosthodontic Department, Faculty of Dentistry, Alexandria University
| | - Hams Abdelrahman
- Dental Public Health Department, Faculty of Dentistry, Alexandria University
| |
Collapse
|
17
|
Luan Q, Becker JH, Macaraniag C, Massad MG, Zhou J, Shimamura T, Papautsky I. Non-small cell lung carcinoma spheroid models in agarose microwells for drug response studies. LAB ON A CHIP 2022; 22:2364-2375. [PMID: 35551303 DOI: 10.1039/d2lc00244b] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
There is a growing interest in developing personalized treatment strategies for each cancer patient, especially those with non-small cell lung carcinoma (NSCLC) which annually accounts for the majority of cancer related deaths in the US. Yet identifying the optimal NSCLC treatment strategy for each cancer patient is critical due to a multitude of mutations, some of which develop following initial therapy and can result in drug resistance. A key difficulty in developing personalized therapies in NSCLC is the lack of clinically relevant assay systems that are suitable to evaluate drug sensitivity using a minuscule amount of patient-derived material available following biopsies. Herein we leverage 3D printing to demonstrate a platform based on miniature microwells in agarose to culture cancer cell spheroids. The agarose wells were shaped by 3D printing molds with 1000 microwells with a U-shaped bottom. Three NSCLC cell lines (HCC4006, H1975 and A549) were used to demonstrate size uniformity, spheroid viability, biomarker expressions and drug response in 3D agarose microwells. Results show that our approach yielded spheroids of uniform size (coefficient of variation <22%) and high viability (>83% after 1 week-culture). Studies using epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKIs) drugs gefitinib and osimertinib showed clinically relevant responses. Based on the physical features, cell phenotypes, and responses to therapy of our spheroid models, we conclude that our platform is suitable for in vitro culture and drug evaluation, especially in cases when tumor sample is limited.
Collapse
Affiliation(s)
- Qiyue Luan
- Department of Biomedical Engineering, University of Illinois Chicago, 851 S. Morgan Street, 218 SEO, Chicago, IL 60607, USA.
| | - Jeffrey H Becker
- Department of Surgery, University of Illinois Chicago, Chicago, IL 60612, USA
- University of Illinois Cancer Center, Chicago, IL 60612, USA
| | - Celine Macaraniag
- Department of Biomedical Engineering, University of Illinois Chicago, 851 S. Morgan Street, 218 SEO, Chicago, IL 60607, USA.
| | - Malek G Massad
- Department of Surgery, University of Illinois Chicago, Chicago, IL 60612, USA
| | - Jian Zhou
- Department of Biomedical Engineering, University of Illinois Chicago, 851 S. Morgan Street, 218 SEO, Chicago, IL 60607, USA.
- University of Illinois Cancer Center, Chicago, IL 60612, USA
| | - Takeshi Shimamura
- Department of Surgery, University of Illinois Chicago, Chicago, IL 60612, USA
- University of Illinois Cancer Center, Chicago, IL 60612, USA
| | - Ian Papautsky
- Department of Biomedical Engineering, University of Illinois Chicago, 851 S. Morgan Street, 218 SEO, Chicago, IL 60607, USA.
- University of Illinois Cancer Center, Chicago, IL 60612, USA
| |
Collapse
|
18
|
Wettability and Surface Roughness of Parylene C on Three-Dimensional-Printed Photopolymers. MATERIALS 2022; 15:ma15124159. [PMID: 35744218 PMCID: PMC9228345 DOI: 10.3390/ma15124159] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 06/02/2022] [Accepted: 06/09/2022] [Indexed: 11/21/2022]
Abstract
The use of poly-(para-chloro-xylylene) (Parylene C) in microelectromechanical systems and medical devices has increased rapidly. However, little research has been conducted on the wettability and surface roughness of Parylene C after being soaked in solutions. In this study, the contact angle and surface roughness (arithmetic average of roughness) of Parylene C on three-dimensional (3D)-printed photopolymer in 10% sodium hydroxide, 10% ammonium hydroxide, and 100% phosphate-buffered saline (PBS) solutions were investigated using a commercial contact angle measurement system and laser confocal microscope, respectively. The collected data indicated that 10% ammonium hydroxide had no major effect on the contact angle of Parylene C on a substrate, with a Shore A hardness of 50. However, 10% sodium hydroxide, 10% ammonium hydroxide, and 100% PBS considerably affected the contact angle of Parylene C on a substrate with a Shore A hardness of 85. Substrates with Parylene C coating exhibited lower surface roughness than uncoated substrates. The substrates coated with Parylene C that were soaked in 10% ammonium hydroxide exhibited high surface roughness. The aforementioned results indicate that 3D-printed photopolymers coated with Parylene C can offer potential benefits when used in biocompatible devices.
Collapse
|
19
|
Burkhardt F, Spies BC, Wesemann C, Schirmeister CG, Licht EH, Beuer F, Steinberg T, Pieralli S. Cytotoxicity of polymers intended for the extrusion-based additive manufacturing of surgical guides. Sci Rep 2022; 12:7391. [PMID: 35513701 PMCID: PMC9072356 DOI: 10.1038/s41598-022-11426-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 04/19/2022] [Indexed: 11/09/2022] Open
Abstract
Extrusion-based printing enables simplified and economic manufacturing of surgical guides for oral implant placement. Therefore, the cytotoxicity of a biocopolyester (BE) and a polypropylene (PP), intended for the fused filament fabrication of surgical guides was evaluated. For comparison, a medically certified resin based on methacrylic esters (ME) was printed by stereolithography (n = 18 each group). Human gingival keratinocytes (HGK) were exposed to eluates of the tested materials and an impedance measurement and a tetrazolium assay (MTT) were performed. Modulations in gene expression were analyzed by quantitative PCR. One-way ANOVA with post-hoc Tukey tests were applied. None of the materials exceeded the threshold for cytotoxicity (< 70% viability in MTT) according to ISO 10993-5:2009. The impedance-based cell indices for PP and BE, reflecting cell proliferation, showed little deviations from the control, while ME caused a reduction of up to 45% after 72 h. PCR analysis after 72 h revealed only marginal modulations caused by BE while PP induced a down-regulation of genes encoding for inflammation and apoptosis (p < 0.05). In contrast, the 72 h ME eluate caused an up-regulation of these genes (p < 0.01). All evaluated materials can be considered biocompatible in vitro for short-term application. However, long-term contact to ME might induce (pro-)apoptotic/(pro-)inflammatory responses in HGK.
Collapse
Affiliation(s)
- Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center, Center for Dental Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| | - Benedikt C Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center, Center for Dental Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany
| | - Christian Wesemann
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center, Center for Dental Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.,Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité -Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität Zu Berlin and Berlin Institute of Health, Assmanshauser Str. 4-6, 14197, Berlin, Germany
| | - Carl G Schirmeister
- Freiburg Materials Research Center FMF and Institute for Macromolecular Chemistry, Albert-Ludwigs-University Freiburg, Stefan-Meier-Str. 21, 79104, Freiburg, Germany.,Basell Sales & Marketing B.V., LyondellBasell Industries, Industriepark Höchst, 65926, Frankfurt, Germany
| | - Erik H Licht
- Basell Sales & Marketing B.V., LyondellBasell Industries, Industriepark Höchst, 65926, Frankfurt, Germany
| | - Florian Beuer
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité -Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität Zu Berlin and Berlin Institute of Health, Assmanshauser Str. 4-6, 14197, Berlin, Germany
| | - Thorsten Steinberg
- Division of Oral Biotechnology, Faculty of Medicine, Medical Center, Center for Dental Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany
| | - Stefano Pieralli
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center, Center for Dental Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany
| |
Collapse
|
20
|
Detamornrat U, McAlister E, Hutton ARJ, Larrañeta E, Donnelly RF. The Role of 3D Printing Technology in Microengineering of Microneedles. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2106392. [PMID: 35362226 DOI: 10.1002/smll.202106392] [Citation(s) in RCA: 41] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 03/13/2022] [Indexed: 06/14/2023]
Abstract
Microneedles (MNs) are minimally invasive devices, which have gained extensive interest over the past decades in various fields including drug delivery, disease diagnosis, monitoring, and cosmetics. MN geometry and shape are key parameters that dictate performance and therapeutic efficacy, however, traditional fabrication methods, such as molding, may not be able to offer rapid design modifications. In this regard, the fabrication of MNs using 3D printing technology enables the rapid creation of complex MN prototypes with high accuracy and offers customizable MN devices with a desired shape and dimension. Moreover, 3D printing shows great potential in producing advanced transdermal drug delivery systems and medical devices by integrating MNs with a variety of technologies. This review aims to demonstrate the advantages of exploiting 3D printing technology as a new tool to microengineer MNs. Various 3D printing methods are introduced, and representative MNs manufactured by such approaches are highlighted in detail. The development of advanced MN devices is also included. Finally, clinical translation and future perspectives for the development of MNs using 3D printing are discussed.
Collapse
Affiliation(s)
- Usanee Detamornrat
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Emma McAlister
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Aaron R J Hutton
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Eneko Larrañeta
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| | - Ryan F Donnelly
- School of Pharmacy, Queen's University Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast, BT9 7BL, UK
| |
Collapse
|
21
|
B.Musgrove H, A.Catterton M, R.Pompano R. Applied tutorial for the design and fabrication of biomicrofluidic devices by resin 3D printing. Anal Chim Acta 2022; 1209:339842. [DOI: 10.1016/j.aca.2022.339842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Revised: 04/11/2022] [Accepted: 04/15/2022] [Indexed: 11/01/2022]
|
22
|
Kawai N, Bando M, Yuasa K, Shibasaki M. Comparison of axon extension: PTFE versus PLA formed by a 3D printer. Open Life Sci 2022; 17:302-311. [PMID: 35434370 PMCID: PMC8974396 DOI: 10.1515/biol-2022-0031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 03/03/2022] [Accepted: 03/05/2022] [Indexed: 11/15/2022] Open
Abstract
Abstract
Three-dimensional (3D) printers mainly create 3D objects by stacking thin layers of material. The effect of the tools created using the fused deposition modeling (FDM) 3D printer on nerve cells remains unclear. In this study, the effects of polytetrafluoroethylene (PTFE) models and two different types of polylactic acid (PLA) models (white or natural), were created using the FDM 3D printer on axon extension were compared using the Campenot chamber. Neurons were isolated from the dorsal root ganglia and added to the central compartment of the Campenot chambers after isolation, processing, and culturing. On day 7, after the initiation of the culture, the difference of the axon extensions to the side compartments of each group was confirmed. We also compared the pH and the amount of leakage when each of these chambers was used. The PLA was associated with a shorter axon extension than the PTFE (white p = 0.0078, natural p = 0.00391). No difference in the pH was observed (p = 0.347), but there was a significant difference on multiple group comparison (p = 0.0231) in the amount of leakage of the medium. PTFE was found to be a more suitable material for culturing attachments.
Collapse
Affiliation(s)
- Naofumi Kawai
- Department of Anesthesiology, Kyoto Prefectural University of Medicine , 465 Kajiicho, Kamigyo-Ku, Kyoto-Shi , Kyoto-Fu 604-8404 , Japan
| | - Mizuki Bando
- Department of Anesthesiology, Akashi City Hospital , 1-33, Takasho-Machi, Akashi-Shi , Hyogo-Ken, 673-8501 , Japan
| | - Kento Yuasa
- Department of Anesthesiology, Kyoto Prefectural University of Medicine , 465 Kajiicho, Kamigyo-Ku, Kyoto-Shi , Kyoto-Fu 604-8404 , Japan
| | - Masayuki Shibasaki
- Department of Anesthesiology, Kyoto Prefectural University of Medicine , 465 Kajiicho, Kamigyo-Ku, Kyoto-Shi , Kyoto-Fu 604-8404 , Japan
| |
Collapse
|
23
|
Satzer P, Achleitner L. 3D printing: Economical and supply chain independent single-use plasticware for cell culture. N Biotechnol 2022; 69:55-61. [PMID: 35337999 DOI: 10.1016/j.nbt.2022.03.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 03/16/2022] [Accepted: 03/19/2022] [Indexed: 11/28/2022]
Abstract
3D printing represents a democratization of manufacturing processes, and inexpensive 3D printed parts for cell culture have been tested as replacements for single-use plastics currently unavailable due to worldwide supply chain issues. In addition, such distributed manufacturing of cell culture laboratory materials helps remote areas and developing countries with limited resources. HEK293 cells were used to test printed shake flasks for cell culture applications and their ease of manufacture. Recorded growth curves showed that renewable biodegradable poly(lactic acid) (PLA) thermoplastic is an excellent and economical replacement for single-use plastic shake flasks, which have shipment lead times during pandemic situations or other supply chain disruptions of over 6 months. With a price of 0.60 € in materials, and printing machines with prices lower than one box of single-use pre-sterilized plastic shake flasks (<350€), the use of PLA is very affordable. Low-cost photopolymerization resins were also tested, but the inherent cytotoxicity of these materials prevented cell growth. This was also true for plant-based resins marketed as having low volatile organic compounds (VOC). Treatment of parts to reduce VOC content was partially successful, but not sufficient to sustain prolonged cell growth. A high-cost medical device IIa-class material showed no improved cell growth. Nevertheless, with PLA a low-cost printing material was identified and the use as cell culture compatible material was demonstrated, providing low-cost supply chain independence. In the future, the printing of pilot-scale bioreactors with PLA as a green sustainable material at the point of its use will be possible.
Collapse
Affiliation(s)
- Peter Satzer
- Department of Biotechnology, Institute of Bioprocess Engineering, University of Natural Resources and Life Sciences, Vienna (BOKU), Muthgasse 18, 1190 Vienna, Austria.
| | - Lena Achleitner
- Department of Biotechnology, Institute of Bioprocess Engineering, University of Natural Resources and Life Sciences, Vienna (BOKU), Muthgasse 18, 1190 Vienna, Austria; acib - Austrian Centre of Industrial Biotechnology, Muthgasse 11, 1190 Vienna, Austria
| |
Collapse
|
24
|
Currens ER, Armbruster MR, Castiaux AD, Edwards JL, Martin RS. Evaluation and optimization of PolyJet 3D-printed materials for cell culture studies. Anal Bioanal Chem 2022; 414:3329-3339. [PMID: 35274156 PMCID: PMC9018575 DOI: 10.1007/s00216-022-03991-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 02/23/2022] [Accepted: 02/25/2022] [Indexed: 12/22/2022]
Abstract
Use of 3D printing for microfluidics is a rapidly growing area, with applications involving cell culture in these devices also becoming of interest. 3D printing can be used to create custom-designed devices that have complex features and integrate different material types in one device; however, there are fewer studies studying the ability to culture cells on the various substrates that are available. This work describes the effect of PolyJet 3D-printing technology on cell culture of two cell lines, bovine pulmonary artery endothelial cells (BPAECs) and Madin-Darby Canine Kidney (MDCK) cells, on two different types of printed materials (VeroClear or MED610). It was found that untreated devices, when used for studies of 1 day or more, led to unsuccessful culture. A variety of device treatment methodologies were investigated, with the most success coming from the use of sodium hydroxide/sodium metasilicate solution. Devices treated with this cleaning step resulted in culture of BPAECs and MDCK cells that were more similar to what is obtained in traditional culture flasks (in terms of cell morphology, viability, and cell density). LC-MS/MS analysis (via Orbitrap MS) was used to determine potential leachates from untreated devices. Finally, the use of a fiber scaffold in the devices was utilized to further evaluate the treatment methodology and to also demonstrate the ability to perform 3D culture in such devices. This study will be of use for researchers wanting to utilize these or other cell types in PolyJet-based 3D-printed devices.
Collapse
Affiliation(s)
- Emily R Currens
- Department of Chemistry, Saint Louis University, St. Louis, MO, 63103, USA
| | | | - Andre D Castiaux
- Department of Chemistry, Saint Louis University, St. Louis, MO, 63103, USA.,Center for Additive Manufacturing, Saint Louis University, 3501 Laclede Ave, St. Louis, MO, 63103, USA
| | - James L Edwards
- Department of Chemistry, Saint Louis University, St. Louis, MO, 63103, USA
| | - R Scott Martin
- Department of Chemistry, Saint Louis University, St. Louis, MO, 63103, USA. .,Center for Additive Manufacturing, Saint Louis University, 3501 Laclede Ave, St. Louis, MO, 63103, USA.
| |
Collapse
|
25
|
Kim Y, Alimperti S, Choi P, Noh M. An Inkjet Printed Flexible Electrocorticography (ECoG) Microelectrode Array on a Thin Parylene-C Film. SENSORS 2022; 22:s22031277. [PMID: 35162023 PMCID: PMC8838719 DOI: 10.3390/s22031277] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 01/08/2022] [Accepted: 01/10/2022] [Indexed: 11/16/2022]
Abstract
Electrocorticography (ECoG) is a conventional, invasive technique for recording brain signals from the cortical surface using an array of electrodes. In this study, we developed a highly flexible 22-channel ECoG microelectrode array on a thin Parylene film using novel fabrication techniques. Narrow (<40 µm) and thin (<500 nm) microelectrode patterns were first printed on PDMS, then the patterns were transferred onto Parylene films via vapor deposition and peeling. A custom-designed, 3D-printed connector was built and assembled with the Parylene-based flexible ECoG microelectrode array without soldering. The impedance of the assembled ECoG electrode array was measured in vitro by electrochemical impedance spectroscopy, and the result was consistent. In addition, we conducted in vivo studies by implanting the flexible ECoG sensor in a rat and successfully recording brain signals.
Collapse
Affiliation(s)
- Yoontae Kim
- American Dental Association Science & Research Institute, Gaithersburg, MD 20899, USA; (Y.K.); (S.A.)
| | - Stella Alimperti
- American Dental Association Science & Research Institute, Gaithersburg, MD 20899, USA; (Y.K.); (S.A.)
| | - Paul Choi
- Department of Electrical and Computer Engineering, University of Texas Rio Grande Valley, Edinburg, TX 78539, USA;
| | - Moses Noh
- Department of Mechanical Engineering and Mechanics, Drexel University, Philadelphia, PA 19104, USA
- Correspondence:
| |
Collapse
|
26
|
Trends in Drug- and Vaccine-based Dissolvable Microneedle Materials and Methods of Fabrication. Eur J Pharm Biopharm 2022; 173:54-72. [DOI: 10.1016/j.ejpb.2022.02.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 01/24/2022] [Accepted: 02/19/2022] [Indexed: 12/18/2022]
|
27
|
Low-Cost Resin 3-D Printing for Rapid Prototyping of Microdevices: Opportunities for Supporting Aquatic Germplasm Repositories. FISHES 2022; 7:49. [PMID: 36644437 PMCID: PMC9838218 DOI: 10.3390/fishes7010049] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Germplasm repositories can benefit sustainable aquaculture by supporting genetic improvement, assisted reproduction, and management of valuable genetic resources. Lack of reliable quality management tools has impeded repository development in the past several decades. Microfabricated open-hardware devices have emerged as a new approach to assist repository development by providing standardized quality assessment capabilities to enable routine quality control. However, prototyping of microfabricated devices (microdevices) traditionally relies on photolithography techniques that are costly, time intensive, and accessible only through specialized engineering laboratories. Although resin 3-D printing has been introduced into the microfabrication domain, existing publications focus on customized or high-cost (>thousands of USD) printers. The goal of this report was to identify and call attention to the emerging opportunities to support innovation in microfabrication by use of low-cost (<USD 350) resin 3-D printing for rapid prototyping. We demonstrate that low-cost mask-based stereolithography (MSLA) 3-D printers with straightforward modifications can provide fabrication quality that approaches traditional photolithography techniques. For example, reliable feature sizes of 20 μm with dimensional discrepancy of <4% for lateral dimensions and <5% for vertical dimensions were fabricated with a consumer-level MSLA printers. In addition, alterations made to pre-processing, post-processing, and printer configuration steps improved print quality as demonstrated in objects with sharper edges and smoother surfaces. The prototyping time and cost of resin 3-D printing (3 h with USD 0.5/prototype) were considerably lower than those of traditional photolithography (5 d with USD 80/prototype). With the rapid advance of consumer-grade printers, resin 3-D printing can revolutionize rapid prototyping approaches for microdevices in the near future, facilitating participation in interdisciplinary development of innovative hardware to support germplasm repository development for aquatic species.
Collapse
|
28
|
Innovative Platform for the Advanced Online Monitoring of Three-Dimensional Cells and Tissue Cultures. Cells 2022; 11:cells11030412. [PMID: 35159222 PMCID: PMC8834321 DOI: 10.3390/cells11030412] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 01/21/2022] [Accepted: 01/22/2022] [Indexed: 12/12/2022] Open
Abstract
The use of 3D cell cultures has gained increasing importance in medical and pharmaceutical research. However, the analysis of the culture medium is hardly representative for the culture conditions within a 3D model which hinders the standardization of 3D cultures and translation of results. Therefore, we developed a modular monitoring platform combining a perfusion bioreactor with an integrated minimally invasive sampling system and implemented sensors that enables the online monitoring of culture parameters and medium compounds within 3D cultures. As a proof-of-concept, primary cells as well as cell lines were cultured on a collagen or gelatin methacryloyl (GelMA) hydrogel matrix, while monitoring relevant culture parameters and analytes. Comparing the interstitial fluid of the 3D models versus the corresponding culture medium, we found considerable differences in the concentrations of several analytes. These results clearly demonstrate that analyses of the culture medium only are not relevant for the development of standardized 3D culture processes. The presented bioreactor with an integrated sampling and sensor platform opens new horizons for the development, optimization, and standardization of 3D cultures. Furthermore, this technology holds the potential to reduce animal studies and improve the transferability of pharmaceutical in vitro studies by gaining more relevant results, bridging the gap towards clinical translation.
Collapse
|
29
|
Kelava L, Ivić I, Pakai E, Fekete K, Maroti P, Told R, Ujfalusi Z, Garami A. Stereolithography 3D Printing of a Heat Exchanger for Advanced Temperature Control in Wire Myography. Polymers (Basel) 2022; 14:polym14030471. [PMID: 35160461 PMCID: PMC8839612 DOI: 10.3390/polym14030471] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 01/16/2022] [Accepted: 01/20/2022] [Indexed: 12/24/2022] Open
Abstract
We report the additive manufacturing of a heat-exchange device that can be used as a cooling accessory in a wire myograph. Wire myography is used for measuring vasomotor responses in small resistance arteries; however, the commercially available devices are not capable of active cooling. Here, we critically evaluated a transparent resin material, in terms of mechanical, structural, and thermal behavior. Tensile strength tests (67.66 ± 1.31 MPa), Charpy impact strength test (20.70 ± 2.30 kJ/m2), and Shore D hardness measurements (83.0 ± 0.47) underlined the mechanical stability of the material, supported by digital microscopy, which revealed a glass-like structure. Differential scanning calorimetry with thermogravimetry analysis and thermal conductivity measurements showed heat stability until ~250 °C and effective heat insulation. The 3D-printed heat exchanger was tested in thermophysiology experiments measuring the vasomotor responses of rat tail arteries at different temperatures (13, 16, and 36 °C). The heat-exchange device was successfully used as an accessory of the wire myograph system to cool down the experimental chambers and steadily maintain the targeted temperatures. We observed temperature-dependent differences in the vasoconstriction induced by phenylephrine and KCl. In conclusion, the transparent resin material can be used in additive manufacturing of heat-exchange devices for biomedical research, such as wire myography. Our animal experiments underline the importance of temperature-dependent physiological mechanisms, which should be further studied to understand the background of the thermal changes and their consequences.
Collapse
Affiliation(s)
- Leonardo Kelava
- Department of Thermophysiology, Institute for Translational Medicine, Medical School, University of Pecs, H-7624 Pecs, Hungary
| | - Ivan Ivić
- Department of Thermophysiology, Institute for Translational Medicine, Medical School, University of Pecs, H-7624 Pecs, Hungary
| | - Eszter Pakai
- Department of Thermophysiology, Institute for Translational Medicine, Medical School, University of Pecs, H-7624 Pecs, Hungary
| | - Kata Fekete
- Department of Thermophysiology, Institute for Translational Medicine, Medical School, University of Pecs, H-7624 Pecs, Hungary
| | - Peter Maroti
- Medical Simulation Education Center, Medical School, University of Pecs, H-7624 Pecs, Hungary
- 3D Printing and Visualization Center, University of Pecs, H-7624 Pecs, Hungary
| | - Roland Told
- Medical Simulation Education Center, Medical School, University of Pecs, H-7624 Pecs, Hungary
- 3D Printing and Visualization Center, University of Pecs, H-7624 Pecs, Hungary
| | - Zoltan Ujfalusi
- Department of Biophysics, Medical School, University of Pecs, H-7624 Pecs, Hungary
| | - Andras Garami
- Department of Thermophysiology, Institute for Translational Medicine, Medical School, University of Pecs, H-7624 Pecs, Hungary
| |
Collapse
|
30
|
Effects of the Washing Time and Washing Solution on the Biocompatibility and Mechanical Properties of 3D Printed Dental Resin Materials. Polymers (Basel) 2021; 13:polym13244410. [PMID: 34960960 PMCID: PMC8705711 DOI: 10.3390/polym13244410] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 12/05/2021] [Accepted: 12/08/2021] [Indexed: 12/26/2022] Open
Abstract
Three-dimensional (3D) printing technology is highly regarded in the field of dentistry. Three-dimensional printed resin restorations must undergo a washing process to remove residual resin on the surface after they have been manufactured. However, the effect of the use of different washing solutions and washing times on the biocompatibility of the resulting resin restorations is unclear. Therefore, we prepared 3D-printed denture teeth and crown and bridge resin, and then washed them with two washing solutions (isopropyl alcohol and tripropylene glycol monomethyl ether) using different time points (3, 5, 10, 15, 30, 60, and 90 min). After this, the cell viability, cytotoxicity, and status of human gingival fibroblasts were evaluated using confocal laser scanning. We also analyzed the flexural strength, flexural modulus, and surface SEM imaging. Increasing the washing time increased the cell viability and decreased the cytotoxicity (p < 0.001). Confocal laser scanning showed distinct differences in the morphology and number of fibroblasts. Increasing the washing time did not significantly affect the flexural strength and surface, but the flexural modulus of the 90 min washing group was 1.01 ± 0.21 GPa (mean ± standard deviation), which was lower than that of all the other groups and decreased as the washing time increased. This study confirmed that the washing time affected the biocompatibility and mechanical properties of 3D printed dental resins.
Collapse
|
31
|
Microfluidic devices manufacturing with a stereolithographic printer for biological applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 129:112388. [PMID: 34579907 DOI: 10.1016/j.msec.2021.112388] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 07/27/2021] [Accepted: 08/17/2021] [Indexed: 12/19/2022]
Abstract
Stereolithographic printers have revolutionized many manufacturing processes with their capacity to easily produce highly detailed structures. In the field of microfluidics, this technique avoids the use of complex steps and equipment of the conventional technologies. The potential of low force stereolithography technology is analysed for the first time using a Form 3B printer and seven printing resins through the fabrication of microchannels and pillars. Manufacturing performance of internal and superficial channels and pillars is studied for the seven printing resins in different configurations. A complete characterization of printed structures is carried out by optical, confocal and SEM microscopy, and EDX analysis. Internal channels with unobstructed lumen are obtained for diameters and angles greater than 500 μm and 60°, respectively. Outward and inward superficial channels in the range of hundreds of microns can be fabricated with an accurate profile, printing them with a perpendicular orientation respect to the base, allowing a proper uncured resin evacuation. Outward channels are replicated by soft lithography using polydimethylsiloxane. Clear, Model and Tough resins show a good behaviour to be used as master, but Amber and Dental resins present a poor topology transference from the master to the replica. According to the needs of devices used for biological and biomedical research, transparency as well as superficial biocompatibility of some resins is evaluated. Human umbilical vein endothelial cells (HUVEC) adhesion is confirmed on Amber, Dental and Clear resins, but these cells were only able to grow and progress as a cell culture over the Amber resin. Therefore, Amber showed an adequate biocompatibility, in terms of cell adhesion and growth for HUVEC.
Collapse
|
32
|
Catterton MA, Ball AG, Pompano RR. Rapid Fabrication by Digital Light Processing 3D Printing of a SlipChip with Movable Ports for Local Delivery to Ex Vivo Organ Cultures. MICROMACHINES 2021; 12:993. [PMID: 34442615 PMCID: PMC8399530 DOI: 10.3390/mi12080993] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 08/14/2021] [Accepted: 08/18/2021] [Indexed: 12/28/2022]
Abstract
SlipChips are two-part microfluidic devices that can be reconfigured to change fluidic pathways for a wide range of functions, including tissue stimulation. Currently, fabrication of these devices at the prototype stage requires a skilled microfluidic technician, e.g., for wet etching or alignment steps. In most cases, SlipChip functionality requires an optically clear, smooth, and flat surface that is fluorophilic and hydrophobic. Here, we tested digital light processing (DLP) 3D printing, which is rapid, reproducible, and easily shared, as a solution for fabrication of SlipChips at the prototype stage. As a case study, we sought to fabricate a SlipChip intended for local delivery to live tissue slices through a movable microfluidic port. The device was comprised of two multi-layer components: an enclosed channel with a delivery port and a culture chamber for tissue slices with a permeable support. Once the design was optimized, we demonstrated its function by locally delivering a chemical probe to slices of hydrogel and to living tissue with up to 120 µm spatial resolution. By establishing the design principles for 3D printing of SlipChip devices, this work will enhance the ability to rapidly prototype such devices at mid-scale levels of production.
Collapse
Affiliation(s)
- Megan A Catterton
- Department of Chemistry, University of Virginia College of Arts and Science, Charlottesville, VA 22904, USA;
| | - Alexander G Ball
- Department of Microbiology, Immunology and Cancer Biology, University of Virginia School of Medicine, Charlottesville, VA 22903, USA;
| | - Rebecca R Pompano
- Department of Chemistry, University of Virginia College of Arts and Science, Charlottesville, VA 22904, USA;
- Carter Immunology Center and UVA Cancer Center, University of Virginia, Charlottesville, VA 22903, USA
- Department of Biomedical Engineering, University of Virginia School of Engineering and Applied Sciences, Charlottesville, VA 22904-4259, USA
| |
Collapse
|
33
|
Goldstein Y, Spitz S, Turjeman K, Selinger F, Barenholz Y, Ertl P, Benny O, Bavli D. Breaking the Third Wall: Implementing 3D-Printing Technics to Expand the Complexity and Abilities of Multi-Organ-on-a-Chip Devices. MICROMACHINES 2021; 12:627. [PMID: 34071476 PMCID: PMC8227399 DOI: 10.3390/mi12060627] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 05/19/2021] [Accepted: 05/26/2021] [Indexed: 12/12/2022]
Abstract
The understanding that systemic context and tissue crosstalk are essential keys for bridging the gap between in vitro models and in vivo conditions led to a growing effort in the last decade to develop advanced multi-organ-on-a-chip devices. However, many of the proposed devices have failed to implement the means to allow for conditions tailored to each organ individually, a crucial aspect in cell functionality. Here, we present two 3D-print-based fabrication methods for a generic multi-organ-on-a-chip device: One with a PDMS microfluidic core unit and one based on 3D-printed units. The device was designed for culturing different tissues in separate compartments by integrating individual pairs of inlets and outlets, thus enabling tissue-specific perfusion rates that facilitate the generation of individual tissue-adapted perfusion profiles. The device allowed tissue crosstalk using microchannel configuration and permeable membranes used as barriers between individual cell culture compartments. Computational fluid dynamics (CFD) simulation confirmed the capability to generate significant differences in shear stress between the two individual culture compartments, each with a selective shear force. In addition, we provide preliminary findings that indicate the feasibility for biological compatibility for cell culture and long-term incubation in 3D-printed wells. Finally, we offer a cost-effective, accessible protocol enabling the design and fabrication of advanced multi-organ-on-a-chip devices.
Collapse
Affiliation(s)
- Yoel Goldstein
- Institute for Drug Research, The School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem 91120, Israel;
| | - Sarah Spitz
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, 1040 Vienna, Austria; (S.S.); (F.S.); (P.E.)
| | - Keren Turjeman
- Membrane and Liposome Research Lab, Hebrew University Hadassah Medical School, Jerusalem 91120, Israel; (K.T.); (Y.B.)
| | - Florian Selinger
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, 1040 Vienna, Austria; (S.S.); (F.S.); (P.E.)
| | - Yechezkel Barenholz
- Membrane and Liposome Research Lab, Hebrew University Hadassah Medical School, Jerusalem 91120, Israel; (K.T.); (Y.B.)
| | - Peter Ertl
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, 1040 Vienna, Austria; (S.S.); (F.S.); (P.E.)
| | - Ofra Benny
- Institute for Drug Research, The School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem 91120, Israel;
| | - Danny Bavli
- Membrane and Liposome Research Lab, Hebrew University Hadassah Medical School, Jerusalem 91120, Israel; (K.T.); (Y.B.)
| |
Collapse
|
34
|
Garot C, Bettega G, Picart C. Additive Manufacturing of Material Scaffolds for Bone Regeneration: Toward Application in the Clinics. ADVANCED FUNCTIONAL MATERIALS 2021; 31:2006967. [PMID: 33531885 PMCID: PMC7116655 DOI: 10.1002/adfm.202006967] [Citation(s) in RCA: 63] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Indexed: 05/07/2023]
Abstract
Additive manufacturing (AM) allows the fabrication of customized bone scaffolds in terms of shape, pore size, material type and mechanical properties. Combined with the possibility to obtain a precise 3D image of the bone defects using computed tomography or magnetic resonance imaging, it is now possible to manufacture implants for patient-specific bone regeneration. This paper reviews the state-of-the-art of the different materials and AM techniques used for the fabrication of 3D-printed scaffolds in the field of bone tissue engineering. Their advantages and drawbacks are highlighted. For materials, specific criteria, were extracted from a literature study: biomimetism to native bone, mechanical properties, biodegradability, ability to be imaged (implantation and follow-up period), histological performances and sterilization process. AM techniques can be classified in three major categories: extrusion-based, powder-based and liquid-base. Their price, ease of use and space requirement are analyzed. Different combinations of materials/AM techniques appear to be the most relevant depending on the targeted clinical applications (implantation site, presence of mechanical constraints, temporary or permanent implant). Finally, some barriers impeding the translation to human clinics are identified, notably the sterilization process.
Collapse
Affiliation(s)
- Charlotte Garot
- CEA, Université de Grenoble Alpes, CNRS, ERL 5000, IRIG Institute, 17 rue des Martyrs, F-38054, Grenoble, France
- CNRS and Grenoble Institute of Engineering, UMR 5628, LMGP, 3 parvis Louis Néel F-38016 Grenoble, France
| | - Georges Bettega
- Service de chirurgie maxillo-faciale, Centre Hospitalier Annecy-Genevois, 1 avenue de l’hôpital, F-74370 Epagny Metz-Tessy, France
- INSERM U1209, Institut Albert Bonniot, F-38000 Grenoble, France
| | - Catherine Picart
- CEA, Université de Grenoble Alpes, CNRS, ERL 5000, IRIG Institute, 17 rue des Martyrs, F-38054, Grenoble, France
- CNRS and Grenoble Institute of Engineering, UMR 5628, LMGP, 3 parvis Louis Néel F-38016 Grenoble, France
| |
Collapse
|
35
|
Economidou SN, Pissinato Pere CP, Okereke M, Douroumis D. Optimisation of Design and Manufacturing Parameters of 3D Printed Solid Microneedles for Improved Strength, Sharpness, and Drug Delivery. MICROMACHINES 2021; 12:mi12020117. [PMID: 33499301 PMCID: PMC7912255 DOI: 10.3390/mi12020117] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Revised: 01/15/2021] [Accepted: 01/16/2021] [Indexed: 12/20/2022]
Abstract
3D printing has emerged as a powerful manufacturing technology and has attracted significant attention for the fabrication of microneedle (MN)-mediated transdermal systems. In this work, we describe an optimisation strategy for 3D-printed MNs, ranging from the design to the drug delivery stage. The key relationships between design and manufacturing parameters and quality and performance are systematically explored. The printing and post-printing set parameters were found to influence quality and material mechanical properties, respectively. It was demonstrated that the MN geometry affected piercing behaviour, fracture, and coating morphology. The delivery of insulin in porcine skin by inkjet-coated MNs was shown to be influenced by MN design.
Collapse
Affiliation(s)
- Sophia N. Economidou
- Medway School of Pharmacy, University of Kent, Medway Campus, Central Avenue, Chatham Maritime, Chatham, Kent ME4 4TB, UK;
- Correspondence: (S.N.E.); (D.D.)
| | - Cristiane P. Pissinato Pere
- Medway School of Pharmacy, University of Kent, Medway Campus, Central Avenue, Chatham Maritime, Chatham, Kent ME4 4TB, UK;
| | - Michael Okereke
- Department of Engineering Science, University of Greenwich, Kent ME4 4TB, UK;
| | - Dennis Douroumis
- CIPER Centre for Innovation and Process Engineering Research, Kent ME4 4TB, UK
- Correspondence: (S.N.E.); (D.D.)
| |
Collapse
|