1
|
Alsarani MM, Khan AA, Bautista LSJ, Alsunbul H, Matinlinna JP. Effect of peroxide-free and peroxide-based in-office bleaching on the surface and mechanical properties of CAD/CAM esthetic restorative materials. Eur J Oral Sci 2024; 132:e13016. [PMID: 39272220 DOI: 10.1111/eos.13016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2024] [Accepted: 08/17/2024] [Indexed: 09/15/2024]
Abstract
The study aimed to investigate the influence of H2O2-based and H2O2-free in-office bleaching on the surface and mechanical attributes of CAD/CAM composite blocks. CAD/CAM composite blocks from five different composite materials (CC1, CC2, CC3, CC4, and CC5) were randomly divided into two groups according to bleaching application (H2O2-based and H2O2-free). The surface topography, morphology, nanohardness, elastic modulus, flexural strength, and fracture toughness were measured. A paired and unpaired sample t-tests gauged the effect of pre- and post-bleaching on the substrates. The estimated mean differences (before-after bleaching) suggested an increase in surface roughness for two materials CC2 and CC4, and a significant decrease in nanohardness for material CC4 and in elastic modulus for materials CC2 and CC4 with H2O2-based bleaching, whereas H2O2-free bleaching resulted in changes compatible with no change in these properties. Flexural strength and fracture toughness showed no evidence of changes, irrespective of the bleaching gel used. Scanning electron microscopic analysis revealed erosive effects and micropore formation due to H2O2-based bleaching. H2O2-based bleaching deteriorates the surface of CAD/CAM composite materials while H2O2-free bleaching gel had an insignificant effect on both surface and bulk properties. The clinician should carefully evaluate the potential effects of H2O2-based bleaching on the surface properties of CAD/CAM composites.
Collapse
Affiliation(s)
- Majed M Alsarani
- Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Aftab Ahmed Khan
- Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Leonel S J Bautista
- Dental and Oral Rehabilitation Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Hanan Alsunbul
- Restorative Dentistry Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Jukka P Matinlinna
- Division of Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK
| |
Collapse
|
2
|
Yılmaz K, Özdemir E, Gönüldaş F. Effect of immune-boosting beverage, energy beverage, hydrogen peroxide superior, polishing methods and fine-grained dental prophylaxis paste on color of CAD-CAM restorative materials. BMC Oral Health 2024; 24:1104. [PMID: 39289670 PMCID: PMC11409734 DOI: 10.1186/s12903-024-04895-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Accepted: 09/11/2024] [Indexed: 09/19/2024] Open
Abstract
BACKGROUND The effect of an immune-boosting beverage (SAM) containing Sambucus Nigra, an energy beverage (ENE), an in-office bleaching (BLE) agent with 25% hydrogen peroxide superior, glazing (GLA) or polishing (POL) methods, and professional dental prophylaxis (PDP) on the color of CAD-CAM restorative materials is unknown. METHODS In total 210 specimens were prepared, consisting of CAD-CAM feldspathic (FC), zirconia-reinforced lithium disilicate ceramic (ZLS) and hybrid ceramic (HC). The ceramic specimens were divided according to the polishing methods of glazing (GLA) and mechanical polishing (POL). All materials were divided into two groups: with and without BLE. A 25% hydrogen peroxide superior (HPS) gel was used for BLE. After the baseline (BAS) measurement, the specimens were immersed in 3 different beverages (distilled water (DIS), SAM, ENE). After 28 days, a fine-grained (RDA 7) prophylaxis paste was applied. Statistical analysis of ∆E00 color difference values was performed by 3-way ANOVA and Bonferroni test (α = 0.05). RESULTS The effect of all other actions except material-BLE-beverage on color for BAS-Day 28 was statistically different (p < 0.05). The effect of material, material-BLE, beverage on color for Day 28-PDP was statistically different (p < 0.05). After 28 days, the lowest color change was found in FC-GLA and HC immersed in DIS (p = 0.0001) and the highest in FC-POL immersed in ENE (p = 0.0002). PDP was efficient in color recovery in HC immersed to DIS, ENE and SAM (p = 0.0010). For FC, HC and ZLS, BLE caused a higher color change (p < 0.0001). Regardless of the material, the highest color change for BLE-beverage was found in BLE-treated specimens immersed in ENE (p = 0.0496) and the lowest color change was found in non-BLE-treated specimens immersed in SAM (p = 0.0074). CONCLUSIONS In materials pre-exposed to 25% HPS, the effect of PDP on color recovery was lower than in unexposed materials. After 28 days, mechanical polishing produced higher color change in FC than glazing, however, in ZLS effects of glazing and mechanical polishing on color were similar. For material/polishing method, HC was the most effective. ENE caused higher color change than DIS and SAM. PDP was more effective than ENE in restoring color to DIS- and SAM-immersed specimens.
Collapse
Affiliation(s)
- Kerem Yılmaz
- Department of Prosthodontics, Faculty of Dentistry, Bilimdent Oral and Dental Health Center (ADSUAM), Antalya Bilim University, Tahılpazarı Mahallesi, Kazım Özalp Street, No: 84/D, Floor 9, Muratpaşa, Antalya, 07040, Turkey.
| | | | - Fehmi Gönüldaş
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| |
Collapse
|
3
|
Queiroz J, Amaro LF, Massucatto LO, Dovigo LN, Adabo GL, Fonseca RG. Effect of Successive At-home Bleaching Sessions on the Surface Properties, Biaxial Flexural Strength, and Reliability of CAD-CAM Monolithic Materials. Oper Dent 2024; 49:531-539. [PMID: 39187958 DOI: 10.2341/23-030-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/01/2024] [Indexed: 08/28/2024]
Abstract
Although at-home bleaching can recover the optical properties of stained CAD-CAM monolithic materials, little is known about its impact on their surface and mechanical properties, especially when successive sessions are performed. This study evaluated the effect of successive at-home bleaching sessions on the microhardness, roughness, topography, biaxial flexural strength (BFS), and reliability of CAD-CAM monolithic materials. Disks from Lava Ultimate (LU), Vita Enamic (VE), and IPS Empress CAD (EMP) were fabricated and submitted to up to three bleaching sessions. At-home bleaching was performed with 10% carbamide peroxide, and each session consisted of one application for 10 hours/day for 14 days. The analyses of the aforementioned parameters were assessed before and after the first, second, and third bleaching sessions, except for BFS, which was evaluated at baseline and after the third session. The Weibull modulus was calculated from the BFS data. The microhardness of the three materials as well as the roughness of LU were not affected by the sessions, whereas the roughness of VE and EMP increased from the second session. All materials displayed topographic changes, which became more pronounced with the increase in the number of sessions. Although bleaching decreased the BFS of the materials, it did not adversely affect their reliability. Successive at-home bleaching sessions with the protocol used in the present study cannot be considered a safe procedure for the materials evaluated.
Collapse
Affiliation(s)
- Jfc Queiroz
- João Fernando Carrijo Queiroz, DDS, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo, Brazil
| | - L F Amaro
- Larissa Franco Amaro, graduate student, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo, Brazil
| | - L O Massucatto
- Larissa Oziliero Massucatto, graduate student, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo, Brazil
| | - L N Dovigo
- Lívia Nordi Dovigo, DDS, MSc, PhD, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo, Brazil
| | - G L Adabo
- Gelson Luis Adabo, DDS, MSc, PhD, full professor, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo, Brazil
| | - R G Fonseca
- *Renata Garcia Fonseca, DDS, MSc, PhD, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo, Brazil
| |
Collapse
|
4
|
Jamshidi S, Alaghemand H, Esmaeili B, Gholinia H. Effects of Different Concentrations of Carbamide Peroxide on Color, Surface Roughness, and Hardness of CAD/CAM Dental Ceramics. Clin Exp Dent Res 2024; 10:e916. [PMID: 38970227 PMCID: PMC11226538 DOI: 10.1002/cre2.916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 05/10/2024] [Accepted: 05/21/2024] [Indexed: 07/08/2024] Open
Abstract
OBJECTIVES This study assessed the effects of 15% and 20% carbamide peroxide (CP) on color, surface roughness, and hardness of computer-aided design/computer-aided manufacturing (CAD/CAM) dental ceramics. MATERIALS AND METHODS This in vitro study was conducted on 120 Vita Mark II, Celtra Duo, and Suprinity CAD/CAM ceramic specimens. The ceramic specimens in each group (n = 40) were randomly assigned to two subgroups (n = 20) for polishing and glazing, and their baseline color, surface roughness (Ra), and hardness were assessed. In each subgroup, half of the specimens were exposed to 15% CP, while the other half were exposed to 20% CP. Their color change (ΔE), surface roughness, and hardness were then measured again. Surface roughness, hardness, and color were analyzed sequentially by profilometer, Vickers hardness tester, and spectrophotometer, respectively. Data were analyzed by repeated measures ANOVA, one-way ANOVA, and post hoc Bonferroni test (α = 0.05). RESULTS The surface roughness of all groups significantly increased after bleaching treatment (p < 0.05). Surface hardness of all groups decreased after bleaching treatment, but this reduction was only significant in Vita Mark II subgroups (glazed, polished, 15%, and 20% CP). The ΔE was not clinically and visually perceivable in any group. CONCLUSION The present results revealed that concentration of CP and type of surface treatment affected the surface properties of CAD/CAM ceramics. Type of surface treatment only affected the surface hardness of Vita Mark II ceramics (p < 0.05). Concentration of CP had a significant effect only on polished Vita Mark II.
Collapse
Affiliation(s)
- Saman Jamshidi
- Department of Restorative Dentistry, School of DentistryBabol University of Medical SciencesBabolIran
| | - Homayoun Alaghemand
- Department of Restorative Dentistry, Dental Materials Research Center, School of Dentistry, Health Research InstituteBabol University of Medical SciencesBabolIran
| | - Behnaz Esmaeili
- Health Research Department, Oral Health Research Center, Health Research InstituteBabol University of Medical SciencesBabolIran
| | - Hemmat Gholinia
- Health Research Department, School of Dentistry, Health Research InstituteBabol University of Medical SciencesBabolIran
| |
Collapse
|
5
|
Peña RC, Ramos AC, Dos Santos Nunes Reis JM, Dovigo LN, Salomon JPGO, Del Mar Pérez M, Fonseca RG. Effect of polishing and bleaching on color, whiteness, and translucency of CAD/CAM monolithic materials. J ESTHET RESTOR DENT 2024. [PMID: 39076158 DOI: 10.1111/jerd.13288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 07/04/2024] [Accepted: 07/17/2024] [Indexed: 07/31/2024]
Abstract
OBJECTIVE To evaluate the effect of polishing and bleaching on the recovery of lightness, color, whiteness, and relative translucency parameter (RTP) in CAD/CAM materials and changes in these properties when another staining in coffee was conducted after the treatments. MATERIALS AND METHODS Disks of Lava Ultimate (LU), Vita Enamic (VE), IPS Empress CAD (EMP), IPS e.max CAD (EMAX), and Vita Suprinity (VS) were (1) not treated (control), (2) polished with Proxyt or (3) Ceramisté, (4) bleached with Opalescence PF or (5) Whiteness HP Blue, and (6) air polished with Clinpro Prophy Powder. CIE L*a*b* color coordinates were registered at baseline (R0), after staining with coffee for 30 min daily for 36.5 days and treatment (R1), and after another staining (R2). Differences (R1-R0 and R2-R0) in lightness (ΔL00), color (ΔE00), RTP (ΔRTP00), and whiteness (ΔWID) were evaluated by mixed repeated measures ANOVA and 95% confidence intervals (α = 0.05) and interpreted in function of their respective 50:50% PT and AT thresholds. Topography was evaluated by scanning electron microscopy (SEM). RESULTS In LU, Opalescence PF and Proxyt decreasedΔ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ ,Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {\mathrm{R}}_0\right)} $$ , andΔWI D R 1 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_1\hbox{--} {R}_0\right)} $$ and showed lowerΔ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ ,Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , andΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ . In VE, all treatments decreasedΔ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ ,Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , andΔWI D R 1 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_1\hbox{--} {R}_0\right)} $$ , whereasΔ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ ,Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , andΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ were lower in Opalescence PF than in the control group. In both moments, ΔE00 and ΔWID in EMP (also ΔL00) and EMAX were higher in Opalescence PF than in the control group, from which the other treatments did not differ in R1-R0. In EMP,Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ in Whiteness HP Blue (alsoΔ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ ) and Proxyt were also higher in comparison to the control group and in VS, Ceramisté decreasedΔ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ ,Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , andΔ R T P 00 R 1 - R 0 $$ \varDelta RT{P}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , whereas Opalescence PF increasedΔRTP 00 R 1 - R 0 $$ {\Delta \mathrm{RTP}}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ .Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ of Ceramisté andΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ andΔ R T P 00 R 2 - R 0 $$ \varDelta RT{P}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ of Proxyt were lower than those of the control group. CONCLUSIONS The most suitable treatment to recover the lightness, color, whiteness, and RTP without changing these properties after another coffee exposure is material-dependent. CLINICAL SIGNIFICANCE Although the effectiveness of the treatment was material-dependent, Proxyt was the only treatment that promoted clinically acceptable changes for both LU and VE, while for purely ceramic materials, this condition was observed with Ceramisté and Clinpro Prophy Powder.
Collapse
Affiliation(s)
- Ranulfo Castillo Peña
- Department of Dental Materials and Prosthodontics, Araraquara Dental School, UNESP-Univ. Estadual Paulista, Araraquara, São Paulo, Brazil
| | - Alejandro Cardenas Ramos
- Department of Dental Materials and Prosthodontics, Araraquara Dental School, UNESP-Univ. Estadual Paulista, Araraquara, São Paulo, Brazil
| | | | - Lívia Nordi Dovigo
- Department of Social Dentistry, São Paulo State University (UNESP), School of Dentistry, Araraquara, Brazil
| | | | - María Del Mar Pérez
- Department of Optics, School of Science, University of Granada, IBS Campus Fuente Nueva, Granada, Spain
| | - Renata Garcia Fonseca
- Department of Dental Materials and Prosthodontics, Araraquara Dental School, UNESP-Univ. Estadual Paulista, Araraquara, São Paulo, Brazil
| |
Collapse
|
6
|
Al-Johani H, Alhotan A, Alhijji S, Silikas N, Satterthwaite J. Staining and bleaching susceptibility of zirconia-reinforced lithium silicate glass-ceramics with different thicknesses, translucencies, and fabrication methods. J Prosthet Dent 2024; 131:530.e1-530.e11. [PMID: 38262839 DOI: 10.1016/j.prosdent.2024.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 01/05/2024] [Accepted: 01/08/2024] [Indexed: 01/25/2024]
Abstract
STATEMENT OF PROBLEM The influence of different thicknesses, translucencies, and fabrication methods on the spectrophotometric and topographical properties of zirconia-reinforced lithium silicate glass-ceramics (ZLSs) for dental restorations remains unclear. PURPOSE The purpose of this in vitro study was to investigate the effect of thicknesses, translucencies, and fabrication methods on the color stability, translucency parameter, opalescence parameter, whiteness stability, transmitted irradiance, light transmittance, opacity, gloss, and roughness of ZLSs exposed to coffee staining and bleaching treatments. MATERIAL AND METHODS Two pressable ZLSs (VITA AMBRIA, VA and Celtra Press, CP) and 2 machinable ZLSs (VITA Suprinity, VS and Celtra Duo, CD) were examined at high translucency (HT) and low translucency (LT) levels in 2 thicknesses (n=160). The specimens were evaluated at baseline, after coffee staining, and after bleaching. The color stability (ΔE2000), translucency parameter (TP), opalescence parameter (OP), whiteness index (WID), and whiteness stability (ΔWID) were measured with a spectrophotometer. Transmitted irradiance (It), light transmission (T), and opacity (O) were obtained from a light-polymerizing unit and a polymerization light collection device. Roughness stability (ΔSa%) was determined with an optical profilometer, and gloss stability (ΔGU%) was recorded with a gloss meter. Data of ΔCIE2000, ΔWID, ΔSa%, and ΔGU% were analyzed by 4-way ANOVA, and data of the TP, OP, WID, It, T, and O were analyzed by repeated 4-way ANOVA (α=.05). RESULTS VS-HT exceeded the ΔCIE2000 acceptability threshold after coffee staining and bleaching protocols. Pressable ZLSs exhibited greater color stability than machinable ZLSs. The 1-mm-thick VA, CP, and CD materials exceeded the ΔWID perceptibility threshold after bleaching. The highest TP and OP was displayed by the 1-mm-thick CP after bleaching. ΔGU increased after water storage and decreased after coffee staining and bleaching. ΔSa% significantly increased after bleaching (P<.05). CONCLUSIONS The color stability and other spectrophotometric properties of ZLSs depended on material thickness. The effects of ZLS fabrication methods and translucency levels on their measured properties were inconsistent. Subjecting 1-mm-thick ZLS materials to acidic media adversely impacted their stainability and surface texture.
Collapse
Affiliation(s)
- Hanan Al-Johani
- PhD student, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK.
| | - Abdulaziz Alhotan
- Assistant Professor, Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Saleh Alhijji
- Assistant Professor, Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Nick Silikas
- Full Professor, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK
| | - Julian Satterthwaite
- Full Professor, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK
| |
Collapse
|
7
|
Ikemoto S, Nagamatsu Y, Masaki C, Hosokawa R, Ikeda H. Development of zirconia-based polymer-infiltrated ceramic network for dental restorative material. J Mech Behav Biomed Mater 2024; 150:106320. [PMID: 38134584 DOI: 10.1016/j.jmbbm.2023.106320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/09/2023] [Accepted: 12/11/2023] [Indexed: 12/24/2023]
Abstract
Polymer-infiltrated ceramic network (PICN) materials have gained considerable attention as tooth restorative materials owing to their mechanical compatibility with human teeth. However, the mechanical strength of contemporary PICN materials is lower than those of conventional resin composites and ceramics. This study aims to develop novel high-strength PICN for use as a dental restorative material. Zirconia-based PICN (EXP) was fabricated using 3 mol% yttria tetragonal polycrystalline zirconia powder and resin monomers via slip casting, followed by sintering and polymer infiltration. Comprehensive analyses of the microstructure, mechanical properties, and physicochemical properties of EXP were performed using scanning electron microscopy with energy-dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, inorganic content measurements, three-point bending test, Vickers hardness test, two-body wear test, shear bond strength (SBS) test, surface free energy analysis, and water sorption/solubility test. Commercially available computer-aided design/computer-aided manufacturing (CAD/CAM) materials, including resin composite (CERASMART), silicate-based PICN (ENAMIC), and zirconia ceramic (e.max ZirCAD), were used for comparison. The analyses highlight the dual network structure of EXP, which comprised a zirconia skeleton and an infiltrated resin phase. EXP exhibits a flexural strength of 346.0 ± 46.0 MPa, flexural modulus of 44.0 ± 3.7 GPa, and Vickers hardness of 440.1 ± 51.2 VHN. The mechanical properties of EXP are significantly higher than those of CERASMART and ENAMIC but lower than those of ZirCAD. Notably, the EXP hardness closely mimics that of the human enamel. The wear volume, SBS, and water sorption/solubility of EXP are comparable to those of CERASMART and ENAMIC. Therefore, EXP has potential applications as a tooth restorative material.
Collapse
Affiliation(s)
- Soshi Ikemoto
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan; Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Chihiro Masaki
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Ryuji Hosokawa
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu, 803-8580, Japan.
| |
Collapse
|
8
|
Alamoush RA, Yang J, Alhotan A, Haider J, Matinlinna JP, Elraggal A. The effect of in-office bleaching agents on the Vickers hardness and surface topography of polished and unpolished CAD/CAM composite materials. Sci Rep 2023; 13:15341. [PMID: 37714943 PMCID: PMC10504265 DOI: 10.1038/s41598-023-42415-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 09/10/2023] [Indexed: 09/17/2023] Open
Abstract
In-office bleaching, using hydrogen peroxide, is effective to remove dental enamel stains. However, bleaching agents can deteriorate surface properties of CAD-CAM materials. This in vitro study aimed to investigate the effect of in-office bleaching agents on Vickers hardness and surface topography of polished and unpolished dental CAD-CAM composite materials (Grandio blocs, Lava Ultimate, BRILLIANT Crios, Cerasmart), and a polymer-infiltrated ceramic network block (Vita Enamic). The specimens were randomly divided into two groups: unpolished or polished. The micro-hardness and surface topography of each group were measured before bleaching, after a 60 min bleaching period, and 24-h and one-month post-bleaching. In-office bleaching significantly influenced the Vickers hardness of both the polished and unpolished CAD/CAM composite blocks, with Vita Enamic exhibiting the least hardness stability among all groups. Furthermore, in-office bleaching significantly influenced the surface roughness of unpolished CAD/CAM composite blocks. There was a significant difference in hardness reduction between the polished and unpolished specimens for most of the investigated materials at different time points. The bleaching did not influence the surface roughness of the investigated polished group, except for Vita Enamic and Lava Ultimate. However, it did influence the surface roughness of the investigated materials in the unpolished group.
Collapse
Affiliation(s)
- Rasha A Alamoush
- Department of Fixed and Removable Prosthodontics, School of Dentistry, The University of Jordan, Amman, 11942, Jordan
| | - Jiawei Yang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Clinical Research Center for Oral Diseases, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, 11545, Riyadh, Saudi Arabia
| | - Julfikar Haider
- Department of Engineering, Manchester Metropolitan University, Manchester, M1 5GD, UK
- Division of Dentistry, School of Medical Sciences, The University of Manchester, Manchester, M13 9PL, UK
| | - Jukka P Matinlinna
- Division of Dentistry, School of Medical Sciences, The University of Manchester, Manchester, M13 9PL, UK
| | - Alaaeldin Elraggal
- Operative Dentistry, Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| |
Collapse
|