1
|
Yao L, Khan SR, Dolmans G, Romme J, Mitra S. High Accuracy Localization for Miniature Ingestible Devices Using Mutual Inductance. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2024; 18:662-678. [PMID: 38306262 DOI: 10.1109/tbcas.2024.3361045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2024]
Abstract
This article demonstrates an inductively coupled high-accuracy localization system for miniature ingestible devices. It utilizes an inductance double capacitances-series capacitance (LCC-S) compensation architecture that enables mutual inductance measurement at primary side that is positioned outside the human body and less constrained by power budget and size than the miniature ingestible. Depending on the secondary circuit architecture, only limited and simple cooperative measurements are needed from the ingestible secondary side, which saves power and area in the miniature device. The errors in the system are modeled thoroughly, providing insights about system require-ments for a particular localization accuracy target for efficient design and to identify key building blocks with large influence on overall performance. The model shows that sub-centimeter localization root-mean-square error (RMSE) can be achieved with a modest external ADC (18bit) using three primary coils and three secondary coils. The localization is verified along a complete small intestine tract with realistic dimensions. The proposed model is verified by simulation and experiment showing that at the selected frequency range up to 5 MHz the body has no influence on the accuracy. The use of 0.9% saline as phantom is proposed which guarantees the analysis validity for all body types.
Collapse
|
2
|
Cao Q, Deng R, Pan Y, Liu R, Chen Y, Gong G, Zou J, Yang H, Han D. Robotic wireless capsule endoscopy: recent advances and upcoming technologies. Nat Commun 2024; 15:4597. [PMID: 38816464 PMCID: PMC11139981 DOI: 10.1038/s41467-024-49019-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 05/21/2024] [Indexed: 06/01/2024] Open
Abstract
Wireless capsule endoscopy (WCE) offers a non-invasive evaluation of the digestive system, eliminating the need for sedation and the risks associated with conventional endoscopic procedures. Its significance lies in diagnosing gastrointestinal tissue irregularities, especially in the small intestine. However, existing commercial WCE devices face limitations, such as the absence of autonomous lesion detection and treatment capabilities. Recent advancements in micro-electromechanical fabrication and computational methods have led to extensive research in sophisticated technology integration into commercial capsule endoscopes, intending to supersede wired endoscopes. This Review discusses the future requirements for intelligent capsule robots, providing a comparative evaluation of various methods' merits and disadvantages, and highlighting recent developments in six technologies relevant to WCE. These include near-field wireless power transmission, magnetic field active drive, ultra-wideband/intrabody communication, hybrid localization, AI-based autonomous lesion detection, and magnetic-controlled diagnosis and treatment. Moreover, we explore the feasibility for future "capsule surgeons".
Collapse
Affiliation(s)
- Qing Cao
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Runyi Deng
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Yue Pan
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Ruijie Liu
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Yicheng Chen
- Sir Run-Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, 310016, China
| | - Guofang Gong
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Jun Zou
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Huayong Yang
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Dong Han
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310027, China.
- School of Mechanical Engineering, Zhejiang University, Hangzhou, 310027, China.
| |
Collapse
|
3
|
Van de Steene T, Tanghe E, Martens L, Garripoli C, Stanzione S, Joseph W. Optimal Frequency and Wireless Power Budget for Miniature Receivers in Obese People. SENSORS (BASEL, SWITZERLAND) 2023; 23:8084. [PMID: 37836914 PMCID: PMC10574982 DOI: 10.3390/s23198084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/19/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023]
Abstract
This study investigates wireless power transfer for deep in-body receivers, determining the optimal frequency, power budget, and design for the transmitter and receiver. In particular, the focus is on small, in-body receivers at large depths up to 20 cm for obese patients. This enables long-term monitoring of the gastrointestinal tract for all body types. Numerical simulations are used to investigate power transfer and losses as a function of frequency and to find the optimal design at the selected frequency for an obese body model. From all ISM-frequencies in the investigated range (1 kHz-10 GHz), the value of 13.56 MHz yields the best performance. This optimum corresponds to the transition from dominant copper losses in conductors to dominant losses in conductive tissue. At this frequency, a transmitting and receiving coil are designed consisting of 12 and 23 windings, respectively. With a power transfer efficiency of 2.70×10-5, 18 µW can be received for an input power of 0.68 W while still satisfying exposure guidelines. The power transfer is validated by measurements. For the first time, efficiency values and the power budget are reported for WPT through 20 cm of tissue to mm sized receivers. Compared to WPT at higher frequencies, as commonly used for small receivers, the proposed system is more suitable for WPT to large depths in-body and comes with the advantage that no focusing is required, which can accommodate multiple receivers and uncertainty about receiver location more easily. The received power allows long-term sensing in the gastrointestinal tract by, e.g., temperature, pressure, and pH sensors, motility sensing, or even gastric stimulation.
Collapse
Affiliation(s)
- Tom Van de Steene
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| | - Emmeric Tanghe
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| | - Luc Martens
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| | | | | | - Wout Joseph
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| |
Collapse
|
4
|
Aliqab K, Nadeem I, Khan SR. A Comprehensive Review of In-Body Biomedical Antennas: Design, Challenges and Applications. MICROMACHINES 2023; 14:1472. [PMID: 37512782 PMCID: PMC10385670 DOI: 10.3390/mi14071472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 07/11/2023] [Accepted: 07/19/2023] [Indexed: 07/30/2023]
Abstract
In-body biomedical devices (IBBDs) are receiving significant attention in the discovery of solutions to complex medical conditions. Biomedical devices, which can be ingested, injected or implanted in the human body, have made it viable to screen the physiological signs of a patient wirelessly, without regular hospital appointments and routine check-ups, where the antenna is a mandatory element for transferring bio-data from the IBBDs to the external world. However, the design of an in-body antenna is challenging due to the dispersion of the dielectric constant of the tissues and unpredictability of the organ structures of the human body, which can absorb most of the antenna radiation. Therefore, various factors must be considered for an in-body antenna, such as miniaturization, link budget, patient safety, biocompatibility, low power consumption and the ability to work effectively within acceptable medical frequency bands. This paper presents a comprehensive overview of the major facets associated with the design and challenges of in-body antennas. The review comprises surveying the design specifications and implementation methodology, simulation software and testing of in-body biomedical antennas. This work aims to summarize the recent in-body antenna innovations for biomedical applications and indicates the key research challenges.
Collapse
Affiliation(s)
- Khaled Aliqab
- Department of Electrical Engineering, College of Engineering, Jouf University, Sakaka 72388, Saudi Arabia
| | - Iram Nadeem
- Department of Information Engineering and Mathematics Science, University of Siena, 53100 Siena, Italy
| | - Sadeque Reza Khan
- Institute of Sensors, Signals and Systems, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, UK
| |
Collapse
|
5
|
Murliky L, Oliveira G, de Sousa FR, Brusamarello VJ. Tracking and Dynamic Tuning of a Wireless Powered Endoscopic Capsule. SENSORS (BASEL, SWITZERLAND) 2022; 22:6924. [PMID: 36146266 PMCID: PMC9506451 DOI: 10.3390/s22186924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 09/03/2022] [Accepted: 09/08/2022] [Indexed: 06/16/2023]
Abstract
This work presents an inductive wireless power transfer system for powering an endoscopy capsule supplying energy to power electronic devices allocated inside a capsule of ≈26.1 mm × 9 mm. A receiver with three coils in quadrature with dimensions of ≈9 mm × 9 mm × 10 mm is located inside the capsule, moving freely inside a transmitter coil with 380 mm diameter through translations and revolutions. The proposed system tracks the variations of the equivalent magnetic coupling coefficient compensating misalignments between the transmitter and receiver coils. The power on the load is estimated and optimized from the transmitter, and the tracking control is performed by actuating on a capacitance in the matching network and on the voltage source frequency. The proposed system can prevent load overheating by limiting the power via adjusting of the magnitude of voltage source VS. Experimental results with uncertainties analysis reveal that, even at low magnetic coupling coefficients k ranging from (1.7 × 10-3, 3.5 × 10-3), the power on the load can be held within the range of 100-130 mW. These results are achieved with any position of the capsule in the space, limited by the diameter of the transmitter coil and height of 200 mm when adjusting the series capacitance of the transmitter in the range (17.4, 19.4) pF and the frequency of the power source in the range (802.1, 809.5) kHz.
Collapse
Affiliation(s)
- Lucas Murliky
- Department of Electrical Engineering, Universidade Federal do Rio Grande do Sul, Porto Alegre 91501-970, Brazil
| | - Gustavo Oliveira
- Department of Electrical Engineering, Universidade Federal do Rio Grande do Sul, Porto Alegre 91501-970, Brazil
| | - Fernando Rangel de Sousa
- Department of Electrical and Electronic Engineering, Universidade Federal de Santa Catarina, Florianópolis 88040-900, Brazil
| | - Valner João Brusamarello
- Department of Electrical Engineering, Universidade Federal do Rio Grande do Sul, Porto Alegre 91501-970, Brazil
| |
Collapse
|
6
|
Khan SR, Mugisha AJ, Tsiamis A, Mitra S. Commercial Off-the-Shelf Components (COTS) in Realizing Miniature Implantable Wireless Medical Devices: A Review. SENSORS 2022; 22:s22103635. [PMID: 35632042 PMCID: PMC9144583 DOI: 10.3390/s22103635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/25/2022] [Accepted: 04/30/2022] [Indexed: 12/04/2022]
Abstract
Over the past decade, there has been exponential growth in the per capita rate of medical patients around the world, and this is significantly straining the resources of healthcare institutes. Therefore, the reliance on smart commercial off-the-shelf (COTS) implantable wireless medical devices (IWMDs) is increasing among healthcare institutions to provide routine medical services, such as monitoring patients' physiological signals and the remote delivery of therapeutic drugs. These smart COTS IWMDs reduce the necessity of recurring visits of patients to healthcare institutions and also mitigate physical contact, which can minimize the possibility of any potential spread of contagious diseases. Furthermore, the devices provide patients with the benefit of recuperating in familiar surroundings. As such, low-cost, ubiquitous COTS IWMDs have engendered the proliferation of telemedicine in healthcare to provide routine medical services. In this paper, a review work on COTS IWMDs is presented at a macro level to discuss the history of IWMDs, different networked COTS IWMDs, health and safety regulations of COTS IWMDs and the importance of organized procurement. Furthermore, we discuss the basic building blocks of IWMDs and how COTS components can contribute to build these blocks over widely researched custom-built application-specific integrated circuits.
Collapse
|
7
|
Optimization Design for Receiving Coil with Novel Structure Based on Mutual Coupling Model in Wireless Power Transmission for Capsule Endoscope. ENERGIES 2020. [DOI: 10.3390/en13236460] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Wireless capsule endoscope (WCE) is a promising technology for noninvasive and painless imaging detection on gastrointestinal (GI) diseases. On the other hand, conventional endoscopes with wires could discomfort patients and cause them to vomit and aerosolize coronavirus if the patients are infected with COVID-19. However, there stands a technical bottleneck on power supply for the WCE. With the help of wireless power transmission technology, a hollow receiving coil (RC) is proposed to supply sufficient power and also minimize the size of WCE. A model on mutual inductance between transmitting and receiving coils is proposed to evaluate receiving power when the RC is in a different position and direction of patient’s GI tract. Based on the model, an optimal RC is built to obtain sufficient and stable power. Measurement of mutual inductance with the optimal RC validates high accuracy of the proposed model. The standard deviation of receiving power is very low. WCE with optimum RC gets sufficient power and captures images stably in live pig’s intestine tract. Additionally, the model is little affected by biological tissues. It ensures reliable performance of WCE and makes popular clinical application of WCE possible, which is also a relief to reduce epidemics like COVID-19.
Collapse
|