1
|
Lee EJ, Krassin ZL, Abaci HE, Mahler GJ, Esch MB. Pumped and pumpless microphysiological systems to study (nano)therapeutics. WILEY INTERDISCIPLINARY REVIEWS. NANOMEDICINE AND NANOBIOTECHNOLOGY 2023; 15:e1911. [PMID: 37464464 PMCID: PMC11323280 DOI: 10.1002/wnan.1911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 05/19/2023] [Accepted: 05/23/2023] [Indexed: 07/20/2023]
Abstract
Fluidic microphysiological systems (MPS) are microfluidic cell culture devices that are designed to mimic the biochemical and biophysical in vivo microenvironments of human tissues better than conventional petri dishes or well-plates. MPS-grown tissue cultures can be used for probing new drugs for their potential primary and secondary toxicities as well as their efficacy. The systems can also be used for assessing the effects of environmental nanoparticles and nanotheranostics, including their rate of uptake, biodistribution, elimination, and toxicity. Pumpless MPS are a group of MPS that often utilize gravity to recirculate cell culture medium through their microfluidic networks, providing some advantages, but also presenting some challenges. They can be operated with near-physiological amounts of blood surrogate (i.e., cell culture medium) that can recirculate in bidirectional or unidirectional flow patterns depending on the device configuration. Here we discuss recent advances in the design and use of both pumped and pumpless MPS with a focus on where pumpless devices can contribute to realizing the potential future role of MPS in evaluating nanomaterials. This article is categorized under: Therapeutic Approaches and Drug Discovery > Emerging Technologies Toxicology and Regulatory Issues in Nanomedicine > Toxicology of Nanomaterials.
Collapse
Affiliation(s)
- Eun-Jin Lee
- Department of Chemistry and Biochemistry, College of Computer, Mathematical and Natural Sciences, University of Maryland, College Park, Maryland, USA
- Microsystems and Nanotechnology Division, Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
| | - Zachary L Krassin
- Department of Biomedical Engineering, Binghamton University, Binghamton, New York, USA
| | - Hasan Erbil Abaci
- Department of Dermatology, Columbia University Medical Center, New York, New York, USA
| | - Gretchen J Mahler
- Department of Biomedical Engineering, Binghamton University, Binghamton, New York, USA
| | - Mandy B Esch
- Microsystems and Nanotechnology Division, Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
| |
Collapse
|
2
|
Nguyen VVT, Gkouzioti V, Maass C, Verhaar MC, Vernooij RWM, van Balkom BWM. A systematic review of kidney-on-a-chip-based models to study human renal (patho-)physiology. Dis Model Mech 2023; 16:dmm050113. [PMID: 37334839 DOI: 10.1242/dmm.050113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 05/04/2023] [Indexed: 06/21/2023] Open
Abstract
As kidney diseases affect ∼10% of the world population, understanding the underlying mechanisms and developing therapeutic interventions are of high importance. Although animal models have enhanced knowledge of disease mechanisms, human (patho-)physiology may not be adequately represented in animals. Developments in microfluidics and renal cell biology have enabled the development of dynamic models to study renal (patho-)physiology in vitro. Allowing inclusion of human cells and combining different organ models, such as kidney-on-a-chip (KoC) models, enable the refinement and reduction of animal experiments. We systematically reviewed the methodological quality, applicability and effectiveness of kidney-based (multi-)organ-on-a-chip models, and describe the state-of-the-art, strengths and limitations, and opportunities regarding basic research and implementation of these models. We conclude that KoC models have evolved to complex models capable of mimicking systemic (patho-)physiological processes. Commercial chips and human induced pluripotent stem cells and organoids are important for KoC models to study disease mechanisms and assess drug effects, even in a personalized manner. This contributes to the Reduction, Refinement and Replacement of animal models for kidney research. A lack of reporting of intra- and inter-laboratory reproducibility and translational capacity currently hampers implementation of these models.
Collapse
Affiliation(s)
- Vivian V T Nguyen
- Department of Nephrology and Hypertension, UMC Utrecht, 3584CX Utrecht, The Netherlands
| | - Vasiliki Gkouzioti
- Department of Nephrology and Hypertension, UMC Utrecht, 3584CX Utrecht, The Netherlands
| | | | - Marianne C Verhaar
- Department of Nephrology and Hypertension, UMC Utrecht, 3584CX Utrecht, The Netherlands
| | - Robin W M Vernooij
- Department of Nephrology and Hypertension, UMC Utrecht, 3584CX Utrecht, The Netherlands
- Julius Center for Health Sciences and Primary Care, UMC Utrecht, Utrecht University, 3584CX Utrecht, The Netherlands
| | - Bas W M van Balkom
- Department of Nephrology and Hypertension, UMC Utrecht, 3584CX Utrecht, The Netherlands
| |
Collapse
|
3
|
Doi K, Kimura H, Kim SH, Kaneda S, Wada T, Tanaka T, Shimizu A, Sano T, Chikamori M, Shinohara M, Matsunaga YT, Nangaku M, Fujii T. Enhanced podocyte differentiation and changing drug toxicity sensitivity through pressure-controlled mechanical filtration stress on a glomerulus-on-a-chip. LAB ON A CHIP 2023; 23:437-450. [PMID: 36546862 DOI: 10.1039/d2lc00941b] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Podocytes, localized in the glomerulus, are a prognostic factor of proteinuria in kidney disease and are exposed to distinct physiological stimuli from basal to apical filtration flow. Research studies on drug discovery and disease modeling for glomerulopathy have developed a glomerulus-on-a-chip and studied podocyte mechanobiology to realize alternative methods to animal experiments. However, the effect of filtration stimulus on podocytes has remained unclear. Herein, we report the successful development of a user-friendly filtration culture device and system that can precisely control the filtration flow using air pressure control by incorporating a commercially available culture insert. It allows mouse podocytes to be cultured under filtration conditions for three days with a guarantee of maintaining the integrity of the podocyte layer. Using our system, this study demonstrated that podocyte damage caused by hyperfiltration resulting from glomerular hypertension, a common pathophysiology of many glomerulopathies, was successfully recapitulated and that filtration stimulus promotes the maturation of podocytes in terms of their morphology and gene expression. Furthermore, we demonstrated that filtration stimulus induced different drug responsiveness in podocytes than those seen under static conditions, and that the difference in drug responsiveness was dependent on the pharmacological mechanism. Overall, this study has revealed differentiating and pharmacodynamic properties of filtration stimulus and brings new insights into the research field of podocyte mechanobiology towards the realization of glomerulus-on-a-chip.
Collapse
Affiliation(s)
- Kotaro Doi
- Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Hiroshi Kimura
- Micro/Nano Technology Center, Tokai University, Kanagawa, Japan
| | - Soo Hyeon Kim
- Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Shohei Kaneda
- Department of Mechanical Systems Engineering, Faculty of Engineering, Kogakuin University, Tokyo, Japan
| | - Takehiko Wada
- Division of Nephrology, Endocrinology and Metabolism, Tokai University School of Medicine, Kanagawa, Japan
| | - Tetsuhiro Tanaka
- Department of Nephrology, Rheumatology and Endocrinology, Tohoku University Graduate School of Medicine, Miyagi, Japan
| | - Akira Shimizu
- Department of Analytic Human Pathology, Nippon Medical School, Tokyo, Japan
| | - Takanori Sano
- Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | | | - Marie Shinohara
- Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | | | - Masaomi Nangaku
- Division of Nephrology and Endocrinology, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | | |
Collapse
|
4
|
Zhang SY, Mahler GJ. A glomerulus and proximal tubule microphysiological system simulating renal filtration, reabsorption, secretion, and toxicity. LAB ON A CHIP 2023; 23:272-284. [PMID: 36514972 DOI: 10.1039/d2lc00887d] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Microphysiological systems (MPS) are powerful predictive tools for assessing drug-induced kidney injuries. Previous MPS have examined single regions of the nephron, but lack simultaneous filtration, reabsorption, and secretion functionality. Here, we developed a partially open MPS that structurally and functionally recapitulated the glomerular filtration barrier, proximal tubular reabsorption, and secretion for seven days. The system introduced a recirculation circuit and an open filtrate output as a source of functional testing. As a proof-of-concept, a tri-culture of immortalized podocytes, umbilical vein endothelial cells, and proximal tubule (PCT) cells were housed in a single MPS: T-junction, glomerulus housing unit, and PCT chip. The MPS successfully retained blood serum protein, reabsorbed glucose, secreted creatinine, and expressed cell-type specific proteins (VE-cadherin, nephrin, and ZO-1). To simulate drug-induced kidney injuries, the system was perfused with cisplatin and adriamycin, and then tested using serum albumin filtration, glucose clearance, and lactate dehydrogenase release. The glomerulus and PCT MPS demonstrated a complex, dynamic microenvironment and recreated some in vivo-like functions in basal and drug-induced conditions, offering a novel prototype for preclinical testing.
Collapse
Affiliation(s)
- Stephanie Y Zhang
- Department of Biomedical Engineering, Binghamton University, PO Box 6000, Binghamton, NY, 13902, USA.
| | - Gretchen J Mahler
- Department of Biomedical Engineering, Binghamton University, PO Box 6000, Binghamton, NY, 13902, USA.
| |
Collapse
|
5
|
Mahadeo A, Yeung CK, Himmelfarb J, Kelly EJ. Kidney microphysiological models for nephrotoxicity assessment. CURRENT OPINION IN TOXICOLOGY 2022; 30:100341. [PMID: 35495549 PMCID: PMC9053105 DOI: 10.1016/j.cotox.2022.03.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Nephrotoxicity testing is an important step in preclinical development of new molecular entities (NMEs) and has traditionally been performed in 2-D cell culture systems and animal models. However, 2-D culture systems fail to replicate complex in vivo microenvironment and animal models face interspecies differences including the overexpression of drug transporters. In the last decade, 3-D microphysiological systems (MPS) have been developed to address these concerns. Here, we review recent advancements in kidney MPS and their application in drug-induced toxicity testing and kidney disease research. We find that current research is making significant progress addressing MPS limitations such as throughput, incorporating various regions of the nephron such as the glomerulus, and successfully modeling and predicting clinically relevant nephrotoxicity of current and new drugs.
Collapse
Affiliation(s)
- Anish Mahadeo
- Department of Pharmaceutics, University of Washington, Seattle, WA
| | - Catherine K Yeung
- Department of Pharmacy, University of Washington, Seattle, WA
- The Kidney Research Institute, University of Washington, Seattle, WA
| | | | - Edward J Kelly
- Department of Pharmaceutics, University of Washington, Seattle, WA
- The Kidney Research Institute, University of Washington, Seattle, WA
| |
Collapse
|
6
|
Capillary-like Formations of Endothelial Cells in Defined Patterns Generated by Laser Bioprinting. MICROMACHINES 2021; 12:mi12121538. [PMID: 34945388 PMCID: PMC8708310 DOI: 10.3390/mi12121538] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Revised: 12/07/2021] [Accepted: 12/08/2021] [Indexed: 01/17/2023]
Abstract
Bioprinting is seen as a promising technique for tissue engineering, with hopes of one day being able to produce whole organs. However, thick tissue requires a functional vascular network, which naturally contains vessels of various sizes, down to capillaries of ~10 µm in diameter, often spaced less than 200 µm apart. If such thick tissues are to be printed, the vasculature would likely need to be printed at the same time, including the capillaries. While there are many approaches in tissue engineering to produce larger vessels in a defined manner, the small capillaries usually arise only in random patterns by sprouting from the larger vessels or from randomly distributed endothelial cells. Here, we investigated whether the small capillaries could also be printed in predefined patterns. For this purpose, we used a laser-based bioprinting technique that allows for the combination of high resolution and high cell density. Our aim was to achieve the formation of closed tubular structures with lumina by laser-printed endothelial cells along the printed patterns on a surface and in bioprinted tissue. This study shows that such capillaries are directly printable; however, persistence of the printed tubular structures was achieved only in tissue with external stimulation by other cell types.
Collapse
|