1
|
Zath GK, Thomas MM, Loveday EK, Bikos DA, Sanche S, Ke R, Brooke CB, Chang CB. Influenza A viral burst size from thousands of infected single cells using droplet quantitative PCR (dqPCR). PLoS Pathog 2024; 20:e1012257. [PMID: 38950082 PMCID: PMC11244780 DOI: 10.1371/journal.ppat.1012257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 07/12/2024] [Accepted: 05/13/2024] [Indexed: 07/03/2024] Open
Abstract
An important aspect of how viruses spread and infect is the viral burst size, or the number of new viruses produced by each infected cell. Surprisingly, this value remains poorly characterized for influenza A virus (IAV), commonly known as the flu. In this study, we screened tens of thousands of cells using a microfluidic method called droplet quantitative PCR (dqPCR). The high-throughput capability of dqPCR enabled the measurement of a large population of infected cells producing progeny virus. By measuring the fully assembled and successfully released viruses from these infected cells, we discover that the viral burst sizes for both the seasonal H3N2 and the 2009 pandemic H1N1 strains vary significantly, with H3N2 ranging from 101 to 104 viruses per cell, and H1N1 ranging from 101 to 103 viruses per cell. Some infected cells produce average numbers of new viruses, while others generate extensive number of viruses. In fact, we find that only 10% of the single-cell infections are responsible for creating a significant portion of all the viruses. This small fraction produced approximately 60% of new viruses for H3N2 and 40% for H1N1. On average, each infected cell of the H3N2 flu strain produced 709 new viruses, whereas for H1N1, each infected cell produced 358 viruses. This novel method reveals insights into the flu virus and can lead to improved strategies for managing and preventing the spread of viruses.
Collapse
Affiliation(s)
- Geoffrey K. Zath
- Center for Biofilm Engineering, Montana State University, Bozeman, Montana, United States of America
- Department of Chemical and Biological Engineering, Montana State University, Bozeman, Montana, United States of America
| | - Mallory M. Thomas
- Center for Biofilm Engineering, Montana State University, Bozeman, Montana, United States of America
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota, United States of America
- Department of Microbiology and Cell Biology, Montana State University, Bozeman, Montana, United States of America
| | - Emma K. Loveday
- Center for Biofilm Engineering, Montana State University, Bozeman, Montana, United States of America
- Department of Chemical and Biological Engineering, Montana State University, Bozeman, Montana, United States of America
| | - Dimitri A. Bikos
- Center for Biofilm Engineering, Montana State University, Bozeman, Montana, United States of America
- Department of Chemical and Biological Engineering, Montana State University, Bozeman, Montana, United States of America
| | - Steven Sanche
- Theoretical Biology and Biophysics, Los Alamos National Laboratory, Los Alamos, New Mexico, United States of America
| | - Ruian Ke
- Theoretical Biology and Biophysics, Los Alamos National Laboratory, Los Alamos, New Mexico, United States of America
| | - Christopher B. Brooke
- Department of Microbiology, University of Illinois, Urbana-Champaign, Urbana, Illinois, United States of America
| | - Connie B. Chang
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota, United States of America
| |
Collapse
|
2
|
Hasan J, Bok S. Plasmonic Fluorescence Sensors in Diagnosis of Infectious Diseases. BIOSENSORS 2024; 14:130. [PMID: 38534237 DOI: 10.3390/bios14030130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 02/25/2024] [Accepted: 02/26/2024] [Indexed: 03/28/2024]
Abstract
The increasing demand for rapid, cost-effective, and reliable diagnostic tools in personalized and point-of-care medicine is driving scientists to enhance existing technology platforms and develop new methods for detecting and measuring clinically significant biomarkers. Humanity is confronted with growing risks from emerging and recurring infectious diseases, including the influenza virus, dengue virus (DENV), human immunodeficiency virus (HIV), Ebola virus, tuberculosis, cholera, and, most notably, SARS coronavirus-2 (SARS-CoV-2; COVID-19), among others. Timely diagnosis of infections and effective disease control have always been of paramount importance. Plasmonic-based biosensing holds the potential to address the threat posed by infectious diseases by enabling prompt disease monitoring. In recent years, numerous plasmonic platforms have risen to the challenge of offering on-site strategies to complement traditional diagnostic methods like polymerase chain reaction (PCR) and enzyme-linked immunosorbent assays (ELISA). Disease detection can be accomplished through the utilization of diverse plasmonic phenomena, such as propagating surface plasmon resonance (SPR), localized SPR (LSPR), surface-enhanced Raman scattering (SERS), surface-enhanced fluorescence (SEF), surface-enhanced infrared absorption spectroscopy, and plasmonic fluorescence sensors. This review focuses on diagnostic methods employing plasmonic fluorescence sensors, highlighting their pivotal role in swift disease detection with remarkable sensitivity. It underscores the necessity for continued research to expand the scope and capabilities of plasmonic fluorescence sensors in the field of diagnostics.
Collapse
Affiliation(s)
- Juiena Hasan
- Department of Electrical and Computer Engineering, Ritchie School of Engineering and Computer Science, University of Denver, Denver, CO 80208, USA
| | - Sangho Bok
- Department of Electrical and Computer Engineering, Ritchie School of Engineering and Computer Science, University of Denver, Denver, CO 80208, USA
| |
Collapse
|
3
|
Staples J, Dourou AM, Liampa I, Sjaarda C, Moslinger E, Wong H, Sheth PM, Arhondakis S, Prakash R. A Miniaturized System for Rapid, Isothermal Detection of SARS-CoV-2 in Human and Environmental Samples. Biomedicines 2023; 11:2038. [PMID: 37509680 PMCID: PMC10377682 DOI: 10.3390/biomedicines11072038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 07/12/2023] [Accepted: 07/15/2023] [Indexed: 07/30/2023] Open
Abstract
We report a small-footprint cost-effective isothermal rapid DNA amplification system, with integrated microfluidics for automated sample analysis and detection of SARS-CoV-2 in human and environmental samples. Our system measures low-level fluorescent signals in real-time during amplification, while maintaining the desired assay temperature on a low power, portable system footprint. A unique soft microfluidic chip design was implemented to mitigate thermocapillary effects and facilitate optical alignment for automated image capture and signal analysis. The system-on-board prototype, coupled with the LAMP primers designed by BioCoS, was sensitive enough to detect large variations in viral loads of SARS-CoV-2 corresponding to a threshold cycle range of 16 to 39. Furthermore, tested samples consisted of a broad range of viral strains and lineages identified in Canada during 2021-2022. Clinical specimens were collected and tested at the Kingston Health Science Centre using a clinically validated PCR assay, and variants were determined using whole genome sequencing.
Collapse
Affiliation(s)
- Jake Staples
- Department of Electronics Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada
| | | | | | - Calvin Sjaarda
- Kingston Health Sciences Centre, Kingston, ON K7L 2V7, Canada
| | - Emily Moslinger
- Kingston Health Sciences Centre, Kingston, ON K7L 2V7, Canada
| | - Henry Wong
- Kingston Health Sciences Centre, Kingston, ON K7L 2V7, Canada
| | - Prameet M Sheth
- Kingston Health Sciences Centre, Kingston, ON K7L 2V7, Canada
| | | | - Ravi Prakash
- Department of Electronics Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada
| |
Collapse
|
4
|
Tong Z, Shen C, Li Q, Yin H, Mao H. Combining sensors and actuators with electrowetting-on-dielectric (EWOD): advanced digital microfluidic systems for biomedical applications. Analyst 2023; 148:1399-1421. [PMID: 36752059 DOI: 10.1039/d2an01707e] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
The concept of digital microfluidics (DMF) enables highly flexible and precise droplet manipulation at a picoliter scale, making DMF a promising approach to realize integrated, miniaturized "lab-on-a-chip" (LOC) systems for research and clinical purposes. Owing to its simplicity and effectiveness, electrowetting-on-dielectric (EWOD) is one of the most commonly studied and applied effects to implement DMF. However, complex biomedical assays usually require more sophisticated sample handling and detection capabilities than basic EWOD manipulation. Alternatively, combined systems integrating EWOD actuators and other fluidic handling techniques are essential for bringing DMF into practical use. In this paper, we briefly review the main approaches for the integration/combination of EWOD with other microfluidic manipulation methods or additional external fields for specified biomedical applications. The form of integration ranges from independently operating sub-systems to fully coupled hybrid actuators. The corresponding biomedical applications of these works are also summarized to illustrate the significance of these innovative combination attempts.
Collapse
Affiliation(s)
- Zhaoduo Tong
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Chuanjie Shen
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Qiushi Li
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
| | - Hao Yin
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Hongju Mao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
| |
Collapse
|
5
|
Li Q, Zhou X, Wang Q, Liu W, Chen C. Microfluidics for COVID-19: From Current Work to Future Perspective. BIOSENSORS 2023; 13:163. [PMID: 36831930 PMCID: PMC9953302 DOI: 10.3390/bios13020163] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 01/07/2023] [Accepted: 01/14/2023] [Indexed: 06/18/2023]
Abstract
Spread of coronavirus disease 2019 (COVID-19) has significantly impacted the public health and economic sectors. It is urgently necessary to develop rapid, convenient, and cost-effective point-of-care testing (POCT) technologies for the early diagnosis and control of the plague's transmission. Developing POCT methods and related devices is critical for achieving point-of-care diagnosis. With the advantages of miniaturization, high throughput, small sample requirements, and low actual consumption, microfluidics is an essential technology for the development of POCT devices. In this review, according to the different driving forces of the fluid, we introduce the common POCT devices based on microfluidic technology on the market, including paper-based microfluidic, centrifugal microfluidic, optical fluid, and digital microfluidic platforms. Furthermore, various microfluidic-based assays for diagnosing COVID-19 are summarized, including immunoassays, such as ELISA, and molecular assays, such as PCR. Finally, the challenges of and future perspectives on microfluidic device design and development are presented. The ultimate goals of this paper are to provide new insights and directions for the development of microfluidic diagnostics while expecting to contribute to the control of COVID-19.
Collapse
Affiliation(s)
- Qi Li
- Department of Pharmacy, Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410017, China
| | - Xingchen Zhou
- Department of Pharmacy, Xiangya Hospital, Central South University, Changsha 410017, China
| | - Qian Wang
- Department of Pharmacy, Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410017, China
| | - Wenfang Liu
- Department of Pharmacy, Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410017, China
| | - Chuanpin Chen
- Department of Pharmacy, Xiangya School of Pharmaceutical Sciences, Central South University, Changsha 410017, China
| |
Collapse
|
6
|
Chen JJ, Lin ZH. Fabrication of an Oscillating Thermocycler to Analyze the Canine Distemper Virus by Utilizing Reverse Transcription Polymerase Chain Reaction. MICROMACHINES 2022; 13:mi13040600. [PMID: 35457905 PMCID: PMC9026093 DOI: 10.3390/mi13040600] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 03/29/2022] [Accepted: 04/11/2022] [Indexed: 02/04/2023]
Abstract
The reverse transcription-polymerase chain reaction (RT-PCR) has been utilized as an effective tool to diagnose the infectious diseases of viruses. In the present work, the oscillating thermocycler is fabricated and performed to carry out the one-step RT-PCR process successfully. The ribonucleic acid (RNA) mixture is pipetted into the fixed sample volume inside an aluminum reaction block. The sample oscillates the pathway onto the linear motion control system and through the specific RT-PCR heating zones with individual homemade thermal control modules. The present oscillating thermocycler combines the merits of the chamber type and the CF type systems. Before PCR, the reaction chamber moves to the low-temperature zone to complete the RT stage and synthesize the complementary deoxyribonucleic acid (DNA). Next, the low-temperature zone is regulated to the annealing zone. Furthermore, the reactive sample is moved back and forth among three isothermal zones to complete PCR. No extra heating zone is required for the RT stage. The total length of the moving displacement of the chamber is within 100 mm. The miniaturization of the oscillating thermocycler can be expected. In our oscillatory device, the denaturation zone located between the annealing and extension zones is suggested as the appropriate arrangement of the heating blocks. Heat management without thermal cross-talk is easy. Finally, an improved oscillating device is demonstrated to execute the RT-PCR process directly, utilized to amplify the canine distemper virus templates successfully, which could be well applied to a low-cost DNA analysis system in the future.
Collapse
|
7
|
Amirifar L, Besanjideh M, Nasiri R, Shamloo A, Nasrollahi F, de Barros NR, Davoodi E, Erdem A, Mahmoodi M, Hosseini V, Montazerian H, Jahangiry J, Darabi MA, Haghniaz R, Dokmeci MR, Annabi N, Ahadian S, Khademhosseini A. Droplet-based microfluidics in biomedical applications. Biofabrication 2021; 14. [PMID: 34781274 DOI: 10.1088/1758-5090/ac39a9] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 11/15/2021] [Indexed: 11/11/2022]
Abstract
Droplet-based microfluidic systems have been employed to manipulate discrete fluid volumes with immiscible phases. Creating the fluid droplets at microscale has led to a paradigm shift in mixing, sorting, encapsulation, sensing, and designing high throughput devices for biomedical applications. Droplet microfluidics has opened many opportunities in microparticle synthesis, molecular detection, diagnostics, drug delivery, and cell biology. In the present review, we first introduce standard methods for droplet generation (i.e., passive and active methods) and discuss the latest examples of emulsification and particle synthesis approaches enabled by microfluidic platforms. Then, the applications of droplet-based microfluidics in different biomedical applications are detailed. Finally, a general overview of the latest trends along with the perspectives and future potentials in the field are provided.
Collapse
Affiliation(s)
- Leyla Amirifar
- Mechanical Engineering, Sharif University of Technology, Tehran, Iran, Tehran, 11365-11155, Iran (the Islamic Republic of)
| | - Mohsen Besanjideh
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Tehran, 11365-11155, Iran (the Islamic Republic of)
| | - Rohollah Nasiri
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Tehran, 11365-11155, Iran (the Islamic Republic of)
| | - Amir Shamloo
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Tehran, 11365-11155, Iran (the Islamic Republic of)
| | | | - Natan Roberto de Barros
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, Los Angeles, 90024, UNITED STATES
| | - Elham Davoodi
- Bioengineering, University of California - Los Angeles, Los Angeles, Los Angeles, 90095, UNITED STATES
| | - Ahmet Erdem
- Bioengineering, University of California - Los Angeles, Los Angeles, Los Angeles, 90095, UNITED STATES
| | | | - Vahid Hosseini
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, Los Angeles, 90024, UNITED STATES
| | - Hossein Montazerian
- Bioengineering, University of California - Los Angeles, Los Angeles, Los Angeles, 90095, UNITED STATES
| | - Jamileh Jahangiry
- University of California - Los Angeles, Los Angeles, Los Angeles, 90095, UNITED STATES
| | | | - Reihaneh Haghniaz
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, Los Angeles, 90024, UNITED STATES
| | - Mehmet R Dokmeci
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, Los Angeles, 90024, UNITED STATES
| | - Nasim Annabi
- Chemical Engineering, UCLA, Los Angeles, Los Angeles, California, 90095, UNITED STATES
| | - Samad Ahadian
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, Los Angeles, 90024, UNITED STATES
| | - Ali Khademhosseini
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, Los Angeles, 90024, UNITED STATES
| |
Collapse
|
8
|
Zhao Y, Lou J, Zhang H, Sun H, Zhang M, Wang S, Sha X, Zhan Z, Wang Y, Ma C, Li WJ. Measurement methods of single cell drug response. Talanta 2021; 239:123035. [PMID: 34839926 DOI: 10.1016/j.talanta.2021.123035] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 10/26/2021] [Accepted: 11/02/2021] [Indexed: 11/25/2022]
Abstract
In the last decades, a wide multitude of research activity has been focused on the development of new drugs, and devoted to overcome the challenges of high cost and low efficiency in drug evaluation. The measurement of drug response at the single cell level is a quicker, more direct and more accurate way to reflect drug efficacy, which can shorten the drug development period and reduce research costs. Therefore, the single cell drug response (SCDR) measurement technology has aroused extensive attention from researchers, and has become a hot topic in the fields of drug research and cell biology. Recent years have seen the emergence of various SCDR measurement technologies that feature different working principles and different levels of measurement performance. To better examine, compare and summarize the characteristics and functions of these technologies, we select signal-to-noise ratio, throughput, content, invasion, and device complexity as the criteria to evaluate them from the drug efficacy perspective. This review aims to highlight sixteen kinds of SCDR measurement technologies, including patch-clamp technique, live-cell interferometry, capillary electrophoresis, secondary ion mass spectrometry, and more, and report widespread representative examples of SCDR measurement the recent approaches for over the past forty years. Based on their reaction principles, these technologies are classified into four categories: electrical, optical, electrochemical, and mass spectrometry, and a detailed comparison is made between them. After in-depth understanding of these technologies, it is expected to improve or integrate these technologies to propose better SCDR measurement strategies, and explore methods in new drug development and screening, as well as disease diagnosis and treatment.
Collapse
Affiliation(s)
- Yuliang Zhao
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, 066004, China
| | - Jiazhi Lou
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, 066004, China
| | - Hongyu Zhang
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, 066004, China
| | - Hui Sun
- Department of Mechanical Engineering, City University of Hong Kong, Kowloon, Hong Kong, 999077, China
| | - Menglin Zhang
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, 066004, China
| | - Shuyu Wang
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, 066004, China
| | - Xiaopeng Sha
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, 066004, China
| | - Zhikun Zhan
- School of Electrical Engineering, Yanshan University at Qinhuangdao, Qinhuangdao, 066004, China.
| | - Ying Wang
- Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, 100191, China
| | - Cuihua Ma
- Department of Clinical Laboratory, First Hospital of Qinhuangdao, Qinhuangdao, 066004, China.
| | - Wen Jung Li
- Department of Mechanical Engineering, City University of Hong Kong, Kowloon, Hong Kong, 999077, China.
| |
Collapse
|
9
|
Krokhine S, Torabi H, Doostmohammadi A, Rezai P. Conventional and microfluidic methods for airborne virus isolation and detection. Colloids Surf B Biointerfaces 2021; 206:111962. [PMID: 34352699 PMCID: PMC8249716 DOI: 10.1016/j.colsurfb.2021.111962] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 06/22/2021] [Accepted: 06/29/2021] [Indexed: 12/23/2022]
Abstract
With the COVID-19 pandemic, the threat of infectious diseases to public health and safety has become much more apparent. Viral, bacterial and fungal diseases have led to the loss of millions of lives, especially in the developing world. Diseases caused by airborne viruses like SARS-CoV-2 are difficult to control, as these viruses are easily transmissible and can circulate in the air for hours. To contain outbreaks of viruses such as SARS-CoV-2 and institute targeted precautions, it is important to detect them in air and understand how they infect their targets. Point-of-care (PoC) diagnostics and point-of-need (PoN) detection methods are necessary to rapidly test patient and environmental samples, so precautions can immediately be applied. Traditional benchtop detection methods such as ELISA, PCR and culture are not suitable for PoC and PoN monitoring, because they can take hours to days and require specialized equipment. Microfluidic devices can be made at low cost to perform such assays rapidly and at the PoN. They can also be integrated with air- and liquid-based sampling technologies to capture and analyze viruses from air and body fluids. Here, conventional and microfluidic virus detection methods are reviewed and compared. The use of air sampling devices to capture and concentrate viruses is discussed first, followed by a review of analysis methods such as immunoassays, RT-PCR and isothermal amplification in conventional and microfluidic platforms. This review provides an overview of the capabilities of microfluidics in virus handling and detection, which will be useful to infectious disease researchers, biomedical engineers, and public health agencies.
Collapse
Affiliation(s)
- Sophie Krokhine
- Faculty of Science, McMaster University, Burke Science Building, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada.
| | - Hadis Torabi
- Department of Biomedical Engineering, University of Isfahan, Iran.
| | | | - Pouya Rezai
- Department of Mechanical Engineering, York University, ON, Canada.
| |
Collapse
|
10
|
Kang BH, Lee Y, Yu ES, Na H, Kang M, Huh HJ, Jeong KH. Ultrafast and Real-Time Nanoplasmonic On-Chip Polymerase Chain Reaction for Rapid and Quantitative Molecular Diagnostics. ACS NANO 2021; 15:10194-10202. [PMID: 34008961 DOI: 10.1021/acsnano.1c02154] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Advent and fast spread of pandemic diseases draw worldwide attention to rapid, prompt, and accurate molecular diagnostics with technical development of ultrafast polymerase chain reaction (PCR). Microfluidic on-chip PCR platforms provide highly efficient and small-volume bioassay for point-of-care diagnostic applications. Here we report ultrafast, real-time, and on-chip nanoplasmonic PCR for rapid and quantitative molecular diagnostics at point-of-care level. The plasmofluidic PCR chip comprises glass nanopillar arrays with Au nanoislands and gas-permeable microfluidic channels, which contain reaction microchamber arrays, a precharged vacuum cell, and a vapor barrier. The on-chip configuration allows both spontaneous sample loading and microbubble-free PCR reaction during which the plasmonic nanopillar arrays result in ultrafast photothermal cycling. After rapid sample loading less than 3 min, two-step PCR results for 40 cycles show rapid amplification in 264 s for lambda-DNA, and 306 s for plasmids expressing SARS-CoV-2 envelope protein. In addition, the in situ cyclic real-time quantification of amplicons clearly demonstrates the amplification efficiencies of more than 91%. This PCR platform can provide rapid point-of-care molecular diagnostics in helping slow the fast-spreading pandemic.
Collapse
Affiliation(s)
- Byoung-Hoon Kang
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Youngseop Lee
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Eun-Sil Yu
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Hamin Na
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Minhee Kang
- Biomedical Engineering Research Center, Smart Healthcare Research Institute, Samsung Medical Center, Seoul 06351, Republic of Korea
- Department of Medical Device Management and Research, SAIHST (Samsung Advanced Institute for Health Sciences and Technology), Sungkyunkwan University, Seoul 06355, Republic of Korea
| | - Hee Jae Huh
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
| | - Ki-Hun Jeong
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
- KAIST Institute for Health Science and Technology (KIHST), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| |
Collapse
|
11
|
Analysis of Bacteriophages with Insulator-Based Dielectrophoresis. MICROMACHINES 2019; 10:mi10070450. [PMID: 31277396 PMCID: PMC6680707 DOI: 10.3390/mi10070450] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Revised: 06/28/2019] [Accepted: 06/30/2019] [Indexed: 02/07/2023]
Abstract
Bacterial viruses or phages have great potential in the medical and agricultural fields as alternatives to antibiotics to control nuisance populations of pathogenic bacteria. However, current analysis and purification protocols for phages tend to be resource intensive and have numbers of limitations, such as impacting phage viability. The present study explores the potential of employing the electrokinetic technique of insulator-based dielectrophoresis (iDEP) for virus assessment, separation and enrichment. In particular, the application of the parameter "trapping value" (Tv) is explored as a standardized iDEP signature for each phage species. The present study includes mathematical modeling with COMSOL Multiphysics and extensive experimentation. Three related, but genetically and structurally distinct, phages were studied: Salmonella enterica phage SPN3US, Pseudomonas aeruginosa phage ϕKZ and P. chlororaphis phage 201ϕ2-1. This is the first iDEP study on bacteriophages with large and complex virions and the results illustrate their virions can be successfully enriched with iDEP systems and still retain infectivity. In addition, our results indicate that characterization of the negative dielectrophoretic response of a phage in terms of Tv could be used for predicting individual virus behavior in iDEP systems. The findings reported here can contribute to the establishment of protocols to analyze, purify and/or enrich samples of known and unknown phages.
Collapse
|
12
|
Moazami E, Perry JM, Soffer G, Husser MC, Shih SCC. Integration of World-to-Chip Interfaces with Digital Microfluidics for Bacterial Transformation and Enzymatic Assays. Anal Chem 2019; 91:5159-5168. [DOI: 10.1021/acs.analchem.8b05754] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Ehsan Moazami
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G1M8, Canada
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B1R6, Canada
| | - James M. Perry
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B1R6, Canada
- Department of Biology, Concordia University, Montréal, Québec H4B1R6, Canada
| | - Guy Soffer
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G1M8, Canada
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B1R6, Canada
| | - Mathieu C. Husser
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B1R6, Canada
- Department of Biology, Concordia University, Montréal, Québec H4B1R6, Canada
| | - Steve C. C. Shih
- Department of Electrical and Computer Engineering, Concordia University, Montréal, Québec H3G1M8, Canada
- Centre for Applied Synthetic Biology, Concordia University, Montréal, Québec H4B1R6, Canada
- Department of Biology, Concordia University, Montréal, Québec H4B1R6, Canada
| |
Collapse
|
13
|
Campbell JM, Balhoff JB, Landwehr GM, Rahman SM, Vaithiyanathan M, Melvin AT. Microfluidic and Paper-Based Devices for Disease Detection and Diagnostic Research. Int J Mol Sci 2018; 19:E2731. [PMID: 30213089 PMCID: PMC6164778 DOI: 10.3390/ijms19092731] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 09/05/2018] [Accepted: 09/06/2018] [Indexed: 12/12/2022] Open
Abstract
Recent developments in microfluidic devices, nanoparticle chemistry, fluorescent microscopy, and biochemical techniques such as genetic identification and antibody capture have provided easier and more sensitive platforms for detecting and diagnosing diseases as well as providing new fundamental insight into disease progression. These advancements have led to the development of new technology and assays capable of easy and early detection of pathogenicity as well as the enhancement of the drug discovery and development pipeline. While some studies have focused on treatment, many of these technologies have found initial success in laboratories as a precursor for clinical applications. This review highlights the current and future progress of microfluidic techniques geared toward the timely and inexpensive diagnosis of disease including technologies aimed at high-throughput single cell analysis for drug development. It also summarizes novel microfluidic approaches to characterize fundamental cellular behavior and heterogeneity.
Collapse
Affiliation(s)
- Joshua M Campbell
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Joseph B Balhoff
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Grant M Landwehr
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Sharif M Rahman
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | | | - Adam T Melvin
- Cain Department of Chemical Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| |
Collapse
|
14
|
Wuethrich A, Quirino JP. A decade of microchip electrophoresis for clinical diagnostics - A review of 2008-2017. Anal Chim Acta 2018; 1045:42-66. [PMID: 30454573 DOI: 10.1016/j.aca.2018.08.009] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 07/30/2018] [Accepted: 08/03/2018] [Indexed: 01/10/2023]
Abstract
A core element in clinical diagnostics is the data interpretation obtained through the analysis of patient samples. To obtain relevant and reliable information, a methodological approach of sample preparation, separation, and detection is required. Traditionally, these steps are performed independently and stepwise. Microchip capillary electrophoresis (MCE) can provide rapid and high-resolution separation with the capability to integrate a streamlined and complete diagnostic workflow suitable for the point-of-care setting. Whilst standard clinical diagnostics methods normally require hours to days to retrieve specific patient data, MCE can reduce the time to minutes, hastening the delivery of treatment options for the patients. This review covers the advances in MCE for disease detection from 2008 to 2017. Miniaturised diagnostic approaches that required an electrophoretic separation step prior to the detection of the biological samples are reviewed. In the two main sections, the discussion is focused on the technical set-up used to suit MCE for disease detection and on the strategies that have been applied to study various diseases. Throughout these discussions MCE is compared to other techniques to create context of the potential and challenges of MCE. A comprehensive table categorised based on the studied disease using MCE is provided. We also comment on future challenges that remain to be addressed.
Collapse
Affiliation(s)
- Alain Wuethrich
- Centre for Personalised Nanomedicine, Australian Institute for Bioengineering and Nanotechnology (AIBN), University of Queensland, Building 75, Brisbane, QLD, 4072, Australia
| | - Joselito P Quirino
- Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences-Chemistry, University of Tasmania, Private Bag 75, Hobart, TAS, 7001, Australia.
| |
Collapse
|
15
|
Borthakur MP, Biswas G, Bandyopadhyay D. Dynamics of deformation and pinch-off of a migrating compound droplet in a tube. Phys Rev E 2018; 97:043112. [PMID: 29758689 DOI: 10.1103/physreve.97.043112] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2017] [Indexed: 06/08/2023]
Abstract
A computational fluid dynamic investigation has been carried out to study the dynamics of a moving compound droplet inside a tube. The motions associated with such a droplet is uncovered by solving the axisymmetric Navier-Stokes equations in which the spatiotemporal evolution of a pair of twin-deformable interfaces has been tracked employing the volume-of-fluid approach. The deformations at the interfaces and their subsequent dynamics are found to be stimulated by the subtle interplay between the capillary and viscous forces. The simulations uncover that when a compound drop composed of concentric inner and outer interfaces migrates inside a tube, initially in the unsteady domain of evolution, the inner drop shifts away from the concentric position to reach a morphology of constant eccentricity at the steady state. The coupled motions of the droplets in the unsteady regime causes a continuous deformation of the inner and outer interfaces to obtain a configuration with a (an) prolate (oblate) shaped outer (inner) interface. The magnitudes of capillary number and viscosity ratio are found to have significant influence on the temporal evolution of the interfacial deformations as well as the eccentricity of the droplets. Further, the simulations uncover that, following the asymmetric deformation of the interfaces, the migrating compound droplet can undergo an uncommon breakup stimulated by a rather irregular pinch-off of the outer shell. The breakup is found to initiate with the thinning of the outer shell followed by the pinch-off. Interestingly, the kinetics of the thinning of outer shell is found to follow two distinct power-law regimes-a swiftly thinning stage at the onset followed by a rate limiting stage before pinch-off, which eventually leads to the uncommon breakup of the migrating compound droplets.
Collapse
Affiliation(s)
- Manash Pratim Borthakur
- Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati 781039, India
| | - Gautam Biswas
- Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati 781039, India
| | - Dipankar Bandyopadhyay
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati 781039, India
| |
Collapse
|
16
|
Choi W, Yeom SY, Kim J, Jung S, Jung S, Shim TS, Kim SK, Kang JY, Lee SH, Cho IJ, Choi J, Choi N. Hydrogel micropost-based qPCR for multiplex detection of miRNAs associated with Alzheimer's disease. Biosens Bioelectron 2018; 101:235-244. [DOI: 10.1016/j.bios.2017.10.039] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 10/14/2017] [Accepted: 10/16/2017] [Indexed: 12/19/2022]
|
17
|
Fernández-Carballo BL, McBeth C, McGuiness I, Kalashnikov M, Baum C, Borrós S, Sharon A, Sauer-Budge AF. Continuous-flow, microfluidic, qRT-PCR system for RNA virus detection. Anal Bioanal Chem 2017; 410:33-43. [PMID: 29116351 DOI: 10.1007/s00216-017-0689-8] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 09/12/2017] [Accepted: 10/04/2017] [Indexed: 11/24/2022]
Abstract
One of the main challenges in the diagnosis of infectious diseases is the need for rapid and accurate detection of the causative pathogen in any setting. Rapid diagnosis is key to avoiding the spread of the disease, to allow proper clinical decisions to be made in terms of patient treatment, and to mitigate the rise of drug-resistant pathogens. In the last decade, significant interest has been devoted to the development of point-of-care reverse transcription polymerase chain reaction (PCR) platforms for the detection of RNA-based viral pathogens. We present the development of a microfluidic, real-time, fluorescence-based, continuous-flow reverse transcription PCR system. The system incorporates a disposable microfluidic chip designed to be produced industrially with cost-effective roll-to-roll embossing methods. The chip has a long microfluidic channel that directs the PCR solution through areas heated to different temperatures. The solution first travels through a reverse transcription zone where RNA is converted to complementary DNA, which is later amplified and detected in real time as it travels through the thermal cycling area. As a proof of concept, the system was tested for Ebola virus detection. Two different master mixes were tested, and the limit of detection of the system was determined, as was the maximum speed at which amplification occurred. Our results and the versatility of our system suggest its promise for the detection of other RNA-based viruses such as Zika virus or chikungunya virus, which constitute global health threats worldwide. Graphical abstract Photograph of the RT-PCR thermoplastic chip.
Collapse
Affiliation(s)
- B Leticia Fernández-Carballo
- Fraunhofer USA - Center for Manufacturing Innovation, 15 Saint Mary's Street, Brookline, MA, 02446, USA.,Grup d'Enginyeria de Materials (GEMAT), Institut Químic de Sarrià, Universitat Ramón Llull, Via Augusta 390, 08017, Barcelona, Spain
| | - Christine McBeth
- Fraunhofer USA - Center for Manufacturing Innovation, 15 Saint Mary's Street, Brookline, MA, 02446, USA
| | - Ian McGuiness
- Fraunhofer USA - Center for Manufacturing Innovation, 15 Saint Mary's Street, Brookline, MA, 02446, USA
| | - Maxim Kalashnikov
- Fraunhofer USA - Center for Manufacturing Innovation, 15 Saint Mary's Street, Brookline, MA, 02446, USA
| | - Christoph Baum
- Fraunhofer Institute for Production Technology, Steinbachstr. 17, 52074, Aachen, Germany
| | - Salvador Borrós
- Grup d'Enginyeria de Materials (GEMAT), Institut Químic de Sarrià, Universitat Ramón Llull, Via Augusta 390, 08017, Barcelona, Spain
| | - Andre Sharon
- Fraunhofer USA - Center for Manufacturing Innovation, 15 Saint Mary's Street, Brookline, MA, 02446, USA.,Mechanical Engineering Department, Boston University, 110 Cummington Mall, Boston, MA, 02215, USA
| | - Alexis F Sauer-Budge
- Fraunhofer USA - Center for Manufacturing Innovation, 15 Saint Mary's Street, Brookline, MA, 02446, USA. .,Biomedical Engineering Department, Boston University, 44 Cummington Mall, Boston, MA, 02215, USA.
| |
Collapse
|
18
|
Abstract
Nucleic acid based diagnostic techniques are routinely used for the detection of infectious agents. Most of these assays rely on nucleic acid extraction platforms for the extraction and purification of nucleic acids and a separate real-time PCR platform for quantitative nucleic acid amplification tests (NATs). Several microfluidic lab on chip (LOC) technologies have been developed, where mechanical and chemical methods are used for the extraction and purification of nucleic acids. Microfluidic technologies have also been effectively utilized for chip based real-time PCR assays. However, there are few examples of microfluidic systems which have successfully integrated these two key processes. In this study, we have implemented an electro-actuation based LOC micro-device that leverages multi-frequency actuation of samples and reagents droplets for chip based nucleic acid extraction and real-time, reverse transcription (RT) PCR (qRT-PCR) amplification from clinical samples. Our prototype micro-device combines chemical lysis with electric field assisted isolation of nucleic acid in a four channel parallel processing scheme. Furthermore, a four channel parallel qRT-PCR amplification and detection assay is integrated to deliver the sample-to-detection NAT chip. The NAT chip combines dielectrophoresis and electrostatic/electrowetting actuation methods with resistive micro-heaters and temperature sensors to perform chip based integrated NATs. The two chip modules have been validated using different panels of clinical samples and their performance compared with standard platforms. This study has established that our integrated NAT chip system has a sensitivity and specificity comparable to that of the standard platforms while providing up to 10 fold reduction in sample/reagent volumes.
Collapse
|
19
|
Liu W, Gómez-Durán CFA, Smith BD. Fluorescent Neuraminidase Assay Based on Supramolecular Dye Capture After Enzymatic Cleavage. J Am Chem Soc 2017; 139:6390-6395. [PMID: 28426220 DOI: 10.1021/jacs.7b01628] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
A conceptually new type of enzymatic cleavage assay is reported that utilizes in situ supramolecular capture of the fluorescent product. A squaraine-derived substrate with large blocking groups at each end of its structure cannot be threaded by a tetralactam macrocycle until the blocking groups are removed by enzyme cleavage. A prototype design responds to viral neuraminidase, an indicator of influenza infection, and also measures susceptibility of the sample to neuraminidase inhibitor drugs. The substrate structure incorporates three key features: (a) a bis(4-amino-3-hydroxyphenyl)squaraine core with bright deep-red fluorescence and excellent photostability, (b) an N-methyl group at each end of the squaraine core that ensures fast macrocycle threading kinetics, and (c) sialic acid blocking groups that prevent macrocycle threading until they are removed by viral neuraminidase. The enzyme assay can be conducted in aqueous solution where dramatic colorimetric and fluorescence changes are easily observed by the naked eye. Alternatively, affinity capture beads coated with macrocycle can be used to immobilize the liberated squaraine and enable a range of heterogeneous analysis options. With further optimization, this new type of neuraminidase assay may be useful in a point of care clinic to rapidly diagnose influenza infection and also determine which of the approved antiviral inhibitor drugs is likely to be the most effective treatment for an individual patient. The assay design is generalizable and can be readily modified to monitor virtually any type of enzyme-catalyzed cleavage reaction.
Collapse
Affiliation(s)
- Wenqi Liu
- Department of Chemistry and Biochemistry, University of Notre Dame , 236 Nieuwland Science Hall, Notre Dame, Indiana 46556, United States
| | - César F A Gómez-Durán
- Department of Chemistry and Biochemistry, University of Notre Dame , 236 Nieuwland Science Hall, Notre Dame, Indiana 46556, United States
| | - Bradley D Smith
- Department of Chemistry and Biochemistry, University of Notre Dame , 236 Nieuwland Science Hall, Notre Dame, Indiana 46556, United States
| |
Collapse
|
20
|
A Programmable Digital Microfluidic Assay for the Simultaneous Detection of Multiple Anti-Microbial Resistance Genes. MICROMACHINES 2017. [PMCID: PMC6189955 DOI: 10.3390/mi8040111] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The rapid emergence of antimicrobial resistant bacteria requires the development of new diagnostic tests. Nucleic acid-based assays determine antimicrobial susceptibility by detecting genes that encode for the resistance. In this study, we demonstrate rapid and simultaneous detection of three genes that confer resistance in bacteria to extended spectrum β-lactam and carbapenem antibiotics; CTX-M-15, KPC and NDM-1. The assay uses isothermal DNA amplification (recombinase polymerase amplification, RPA) implemented on a programmable digital microfluidics (DMF) platform. Automated dispensing protocols are used to simultaneously manipulate 45 droplets of nL volume containing sample DNA, reagents, and controls. The droplets are processed and mixed under electronic control on the DMF devices with positive amplification measured by fluorescence. The assay on these devices is significantly improved with a Time to Positivity (TTP) half that of the benchtop assay.
Collapse
|
21
|
Samiei E, de Leon Derby MD, den Berg AV, Hoorfar M. An electrohydrodynamic technique for rapid mixing in stationary droplets on digital microfluidic platforms. LAB ON A CHIP 2017; 17:227-234. [PMID: 27957575 DOI: 10.1039/c6lc00997b] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This paper presents an electrohydrodynamic technique for rapid mixing of droplets in open and closed digital microfluidic (DMF) platforms. Mixing is performed by applying a high frequency AC voltage to the coplanar or parallel electrodes, inducing circulation zones inside the droplet which results in rapid mixing of the content. The advantages of the proposed method in comparison to conventional mixing methods that operate based on transporting the droplet back and forth and side to side include 1) a shorter mixing time (as fast as 0.25 s), 2) the use of a fewer number of electrodes, reducing the size of the chip, and 3) the stationary nature of the technique which reduces the chance of cross-contamination and surface biofouling. Mixing using the proposed method is performed to create a uniform mixture after merging a water droplet with another droplet containing either particles or dye. The results show that increasing the frequency, and or the amplitude of the applied voltage, enhances the mixing process. However, actuation with a very high frequency and voltage may result in shedding pico-liter satellite droplets. Therefore, for each frequency there is an effective range of the amplitude which provides rapid mixing and avoids shedding satellite droplets. Also, the increase in the gap height between the two plates (for the closed DMF platforms) significantly enhances the mixing efficiency due to the lower viscous effects. Effects of the addition of salts and DNA to the samples were also studied. The electrothermal effect decreased for these cases, which was solved by increasing the frequency of the applied voltage. To assure the high frequency actuation does not increase the sample temperature excessively, the temperature change was monitored using a thermal imaging camera and it was found that the increase in temperature is negligible.
Collapse
Affiliation(s)
- Ehsan Samiei
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V 1V7, Canada.
| | - Maria Diaz de Leon Derby
- Escuela de Ingeniería y Ciencias, Instituto Tecnológico y de Estudios Superiores de Monterrey, Campus San Luis Potosí, 300 Avenida Eugenio Garza Sada, Lomas del Tecnológico, San Luis Potosí, S.L.P. 78211, Mexico
| | - Andre Van den Berg
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V 1V7, Canada.
| | - Mina Hoorfar
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V 1V7, Canada.
| |
Collapse
|
22
|
Ahrberg CD, Manz A, Chung BG. Polymerase chain reaction in microfluidic devices. LAB ON A CHIP 2016; 16:3866-3884. [PMID: 27713993 DOI: 10.1039/c6lc00984k] [Citation(s) in RCA: 138] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The invention of the polymerase chain reaction (PCR) has caused a revolution in molecular biology, giving access to a method of amplifying deoxyribonucleic acid (DNA) molecules across several orders of magnitude. Since the first application of PCR in a microfluidic device was developed in 1998, an increasing number of researchers have continued the development of microfluidic PCR systems. In this review, we introduce recent developments in microfluidic-based space and time domain devices as well as discuss various designs integrated with multiple functions for sample preparation and detection. The development of isothermal nucleic acid amplification and digital PCR microfluidic devices within the last five years is also highlighted. Furthermore, we introduce various commercial microfluidic PCR devices.
Collapse
Affiliation(s)
| | - Andreas Manz
- Microfluidics group, KIST-Europe, Saarbrücken, Germany and Mechanotronics Department, Universität des Saarlandes, Saarbrücken, Germany
| | - Bong Geun Chung
- Department of Mechanical Engineering, Sogang University, Seoul, Korea.
| |
Collapse
|
23
|
Samiei E, Tabrizian M, Hoorfar M. A review of digital microfluidics as portable platforms for lab-on a-chip applications. LAB ON A CHIP 2016; 16:2376-96. [PMID: 27272540 DOI: 10.1039/c6lc00387g] [Citation(s) in RCA: 195] [Impact Index Per Article: 24.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Following the development of microfluidic systems, there has been a high tendency towards developing lab-on-a-chip devices for biochemical applications. A great deal of effort has been devoted to improve and advance these devices with the goal of performing complete sets of biochemical assays on the device and possibly developing portable platforms for point of care applications. Among the different microfluidic systems used for such a purpose, digital microfluidics (DMF) shows high flexibility and capability of performing multiplex and parallel biochemical operations, and hence, has been considered as a suitable candidate for lab-on-a-chip applications. In this review, we discuss the most recent advances in the DMF platforms, and evaluate the feasibility of developing multifunctional packages for performing complete sets of processes of biochemical assays, particularly for point-of-care applications. The progress in the development of DMF systems is reviewed from eight different aspects, including device fabrication, basic fluidic operations, automation, manipulation of biological samples, advanced operations, detection, biological applications, and finally, packaging and portability of the DMF devices. Success in developing the lab-on-a-chip DMF devices will be concluded based on the advances achieved in each of these aspects.
Collapse
Affiliation(s)
- Ehsan Samiei
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V 1V7, Canada.
| | | | | |
Collapse
|
24
|
Wang Y, Ostlund EN, Jun Y, Nie FP, Li YG, Johnson DJ, Lin R, Li ZG. Combining reverse-transcription multiplex PCR and microfluidic electrophoresis to simultaneously detect seven mosquito-transmitted zoonotic encephalomyelitis viruses. Vet J 2015; 212:27-35. [PMID: 27256022 DOI: 10.1016/j.tvjl.2015.10.040] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2014] [Revised: 10/10/2015] [Accepted: 10/13/2015] [Indexed: 10/22/2022]
Abstract
Several mosquito-transmitted viruses are causative agents for zoonotic encephalomyelitis. Rapid identification of these viruses in mosquito populations is an effective method for surveying these diseases. To detect multiple mosquito-transmitted viral agents, including West Nile virus, Saint Louis encephalitis virus, Venezuelan equine encephalomyelitis virus, Western equine encephalomyelitis virus, Eastern equine encephalomyelitis virus, Highlands J virus and Japanese encephalitis virus, an assay using multiplex reverse-transcription PCR combined with microfluidic electrophoresis was developed and evaluated. Tailed nested primers were used in the assay to amplify specific viral genomic segments, and products with specific length were further analyzed by using a microfluidic electrophoresis chip. The assay exhibited good specificity and analytical sensitivity (10(2) copies/µL). This technology can be helpful in the quarantine and surveillance of exotic encephalomyelitis viruses which are transmitted by mosquitoes.
Collapse
Affiliation(s)
- Yu Wang
- School of Life Sciences, Chongqing University, Chongqing 400030, China; Technical Center of Chongqing Entry Inspection and Quarantine Bureau, Engineering Research Center for Import and Export Food Safety, Chongqing 400020, China
| | - Eileen N Ostlund
- Diagnostic Virology Laboratory, National Veterinary Services Laboratories, STAS/VS/APHIS/USDA, Ames, IA 50010, USA
| | - Yang Jun
- Technical Center of Chongqing Entry Inspection and Quarantine Bureau, Engineering Research Center for Import and Export Food Safety, Chongqing 400020, China
| | - Fu-Ping Nie
- Technical Center of Chongqing Entry Inspection and Quarantine Bureau, Engineering Research Center for Import and Export Food Safety, Chongqing 400020, China
| | - Ying-Guo Li
- School of Life Sciences, Chongqing University, Chongqing 400030, China; Technical Center of Chongqing Entry Inspection and Quarantine Bureau, Engineering Research Center for Import and Export Food Safety, Chongqing 400020, China
| | - Donna J Johnson
- Diagnostic Virology Laboratory, National Veterinary Services Laboratories, STAS/VS/APHIS/USDA, Ames, IA 50010, USA
| | - Rui Lin
- School of Life Sciences, Chongqing University, Chongqing 400030, China
| | - Zheng-Guo Li
- School of Life Sciences, Chongqing University, Chongqing 400030, China.
| |
Collapse
|
25
|
|
26
|
Kaler KVIS, Prakash R. Droplet microfluidics for chip-based diagnostics. SENSORS (BASEL, SWITZERLAND) 2014; 14:23283-306. [PMID: 25490590 PMCID: PMC4299063 DOI: 10.3390/s141223283] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Revised: 11/04/2014] [Accepted: 11/27/2014] [Indexed: 12/29/2022]
Abstract
Droplet microfluidics (DMF) is a fluidic handling technology that enables precision control over dispensing and subsequent manipulation of droplets in the volume range of microliters to picoliters, on a micro-fabricated device. There are several different droplet actuation methods, all of which can generate external stimuli, to either actively or passively control the shape and positioning of fluidic droplets over patterned substrates. In this review article, we focus on the operation and utility of electro-actuation-based DMF devices, which utilize one or more micro-/nano-patterned substrates to facilitate electric field-based handling of chemical and/or biological samples. The underlying theory of DMF actuations, device fabrication methods and integration of optical and opto-electronic detectors is discussed in this review. Example applications of such electro-actuation-based DMF devices have also been included, illustrating the various actuation methods and their utility in conducting chip-based laboratory and clinical diagnostic assays.
Collapse
Affiliation(s)
- Karan V I S Kaler
- Department of Electrical and Computer Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB-T2N 1N4, Canada.
| | - Ravi Prakash
- Department of Electrical and Computer Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB-T2N 1N4, Canada.
| |
Collapse
|