1
|
Detection of Active BoNT/C and D by EndoPep-MS Using MALDI Biotyper Instrument and Comparison with the Mouse Test Bioassay. Toxins (Basel) 2020; 13:toxins13010010. [PMID: 33374240 PMCID: PMC7824663 DOI: 10.3390/toxins13010010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 12/18/2020] [Accepted: 12/21/2020] [Indexed: 11/26/2022] Open
Abstract
Botulinum neurotoxins (BoNTs) are among the most poisonous known biological substances, and therefore the availability of reliable, easy-to use tools for BoNT detection are important goals for food safety and human and animal health. The reference method for toxin detection and identification is the mouse bioassay (MBA). An EndoPep-MS method for BoNT differentiation has been developed based on mass spectrometry. We have validated and implemented the EndoPep-MS method on a Bruker MALDI Biotyper for the detection of BoNT/C and D serotypes. The method was extensively validated using experimentally and naturally contaminated samples comparing the results with those obtained with the MBA. Overall, the limit of detection (LoD) for both C and D toxins were less than or equal to two mouse lethal dose 50 (mLD50) per 500 µL for all tested matrices with the exception of feces spiked with BoNT/C which showed signals not-related to specific peptide fragments. Diagnostic sensitivity, specificity and positive predictive value were 100% (95% CI: 87.66–100%), 96.08% (95% CI: 86.54–99.52%), and 93.33% (95% CI: 78.25–98.20%), respectively, and accuracy was 97.47% (95% CI: 91.15–99.69%). In conclusion, the tests carried out showed that the EndoPep-MS method, initially developed using more powerful mass spectrometers, can be applied to the Bruker MALDI Biotyper instrument with excellent results including for detection of the proteolytic activity of BoNT/C, BoNT/D, BoNT/CD, and BoNT/DC toxins.
Collapse
|
2
|
Tournier JN, Rougeaux C. Anthrax Toxin Detection: From In Vivo Studies to Diagnostic Applications. Microorganisms 2020; 8:microorganisms8081103. [PMID: 32717946 PMCID: PMC7464488 DOI: 10.3390/microorganisms8081103] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 07/19/2020] [Accepted: 07/21/2020] [Indexed: 11/16/2022] Open
Abstract
Anthrax toxins are produced by Bacillus anthracis throughout infection and shape the physiopathogenesis of the disease. They are produced in low quantities but are highly efficient. They have thus been long ignored, but recent biochemical methods have improved our knowledge in animal models. This article reviews the various methods that have been used and how they could be applied to clinical diagnosis.
Collapse
Affiliation(s)
- Jean-Nicolas Tournier
- Unité Bactériologie Biothérapies Anti-infectieuses et Immunité, Institut de Recherche Biomédicale des Armées (IRBA), 1 place Général Valérie André, 91220 Brétigny sur Orge, France;
- Centre National de Référence-Laboratoire Expert Charbon, 1 place Général Valérie André, 91220 Brétigny sur Orge, France
- Innovative Vaccine Laboratory, Institut Pasteur, 28 rue du docteur Roux, 75015 Paris, France
- Ecole du Val-de-Grâce, 1 place Alphonse Laveran, 75005 Paris, France
| | - Clémence Rougeaux
- Unité Bactériologie Biothérapies Anti-infectieuses et Immunité, Institut de Recherche Biomédicale des Armées (IRBA), 1 place Général Valérie André, 91220 Brétigny sur Orge, France;
- Centre National de Référence-Laboratoire Expert Charbon, 1 place Général Valérie André, 91220 Brétigny sur Orge, France
- Correspondence: ; Tel.: +33-178-651-891
| |
Collapse
|
3
|
Petrucca A, Santino I, Gentile G, Mazza D, Viglietta E, Iorio R, Simmaco M, Ferretti A, Borro M. Detection of α-defensin in synovial fluids by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry as an innovative and cost-effective assay for improved definition of periprosthetic joint infections. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8791. [PMID: 32212182 DOI: 10.1002/rcm.8791] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 03/17/2020] [Accepted: 03/22/2020] [Indexed: 06/10/2023]
Abstract
RATIONALE Detection of α-defensins in synovial fluid is gaining more and more interest in the field of correct diagnosis of periprosthetic joint infections (PJIs). At present, they can be assessed by a quantitative enzyme-linked immunosorbent assay which is expensive and time-consuming and by a qualitative lateral flow immunoassay which is rapid but quite expensive and whose clinical sensitivity is debated. Thus, developing an alternative rapid, accurate, and low-cost assay for α-defensins is important to make α-defensins actionable as novel key clinical markers. METHODS Synovial fluid (SF) samples were obtained from 18 patients undergoing revision of primary joint arthroplasty. Of these, eight met the 2013 Musculoskeletal Infection Society (MSIS) criteria for PJIs, the remaining were classified as aseptic failure. Microbiological analysis and Synovasure assays were carried out on all samples. Sample preparation and the matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) settings were adjusted to detect human neutrophil peptide (HNP)-1, -2 and -3 and to obtain optimal results in term of sensitivity and stability. RESULTS MALDI-TOF MS was able to detect HNPs in SF from septic patients. No signals for HNPs were detected in SF from aseptic failure. The limits of detection (LOD) were 2.5 and 1.25 μg/mL for HNP-2 and HNP-1, respectively. The turnaround time of the analysis is 20 min, and SF samples are stable at -20°C for up to 3 days. Assay sensitivity, specificity, and positive and negative predictive values (PPV and NPV) were 100% for all parameters. On the same SF samples, the Synovasure assay showed lower sensitivity specificity, and PPV and NPV of 87.5%, 90%, 87.5% and 90%, respectively. Microbiological analysis of SF confirmed the presence of bacteria only in SF MSIS-positive patients. CONCLUSIONS The reported MALDI-TOF MS assay was able to detect and differentiate HNPs in SF samples and showed a slightly better diagnostic accuracy than the Synovasure assay.
Collapse
Affiliation(s)
- Andrea Petrucca
- Department of Molecular and Clinical Medicine, Sapienza University of Rome, via di Grottarossa 1035, Rome, 00185, Italy
- Sant'Andrea Hospital - Microbiology Unit, via di Grottarossa 1035, Rome, 00189, Italy
| | - Iolanda Santino
- Department of Molecular and Clinical Medicine, Sapienza University of Rome, via di Grottarossa 1035, Rome, 00185, Italy
- Sant'Andrea Hospital - Microbiology Unit, via di Grottarossa 1035, Rome, 00189, Italy
| | - Giovanna Gentile
- Department of Neurosciences, Mental Health and Sensory Organs, Sapienza University of Rome, via di Grottarossa 1035, Rome, 00185, Italy
- Sant'Andrea Hospital, via di Grottarossa 1035, Rome, 00189, Italy
| | - Daniele Mazza
- Sant'Andrea Hospital - Orthopaedic Unit and Kirk Kilgour Sports Injury Centre, via di Grottarossa 1035, Rome, 00189, Italy
- Sapienza University of Rome, via di Grottarossa 1035, Rome, 00185, Italy
| | - Edoardo Viglietta
- Sant'Andrea Hospital - Orthopaedic Unit and Kirk Kilgour Sports Injury Centre, via di Grottarossa 1035, Rome, 00189, Italy
- Sapienza University of Rome, via di Grottarossa 1035, Rome, 00185, Italy
| | - Raffaele Iorio
- Sant'Andrea Hospital - Orthopaedic Unit and Kirk Kilgour Sports Injury Centre, via di Grottarossa 1035, Rome, 00189, Italy
- Sapienza University of Rome, via di Grottarossa 1035, Rome, 00185, Italy
| | - Maurizio Simmaco
- Department of Neurosciences, Mental Health and Sensory Organs, Sapienza University of Rome, via di Grottarossa 1035, Rome, 00185, Italy
- Sant'Andrea Hospital, via di Grottarossa 1035, Rome, 00189, Italy
| | - Andrea Ferretti
- Sant'Andrea Hospital - Orthopaedic Unit and Kirk Kilgour Sports Injury Centre, via di Grottarossa 1035, Rome, 00189, Italy
- Sapienza University of Rome, via di Grottarossa 1035, Rome, 00185, Italy
| | - Marina Borro
- Department of Neurosciences, Mental Health and Sensory Organs, Sapienza University of Rome, via di Grottarossa 1035, Rome, 00185, Italy
- Sant'Andrea Hospital, via di Grottarossa 1035, Rome, 00189, Italy
| |
Collapse
|
4
|
Sensitive detection of type G botulinum neurotoxin through Endopep-MS peptide substrate optimization. Anal Bioanal Chem 2019; 411:5489-5497. [PMID: 31172236 PMCID: PMC6684539 DOI: 10.1007/s00216-019-01926-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 05/06/2019] [Accepted: 05/16/2019] [Indexed: 11/06/2022]
Abstract
Clostridium botulinum produces botulinum neurotoxins (BoNTs) that are one of the most poisonous substances. In order to respond to public health emergencies, there is a need to develop sensitive and specific methods for detecting botulinum toxin in various clinical matrices. Our laboratory has developed a mass spectrometry-based Endopep-MS assay that is able to rapidly detect and differentiate BoNT serotypes A–G by immunoaffinity capture of toxins and detection of unique cleavage products of peptide substrates. To improve the sensitivity of the Endopep-MS assay for the detection of BoNT serotype G, we report here the optimization of synthetic peptide substrates through systematic substitution, deletion, and incorporation of unnatural amino acids. Our data show that the resulting optimized peptides produced a significant improvement (two orders of magnitude) in assay sensitivity and allowed the detection of 0.01 mouseLD50 toxin present in buffer solution.
Collapse
|
5
|
Kolton CB, Marston CK, Stoddard RA, Cossaboom C, Salzer JS, Kozel TR, Gates-Hollingsworth MA, Cleveland CA, Thompson AT, Dalton MF, Yabsley MJ, Hoffmaster AR. Detection of Bacillus anthracis in animal tissues using InBios active anthrax detect rapid test lateral flow immunoassay. Lett Appl Microbiol 2019; 68:480-484. [PMID: 30776143 DOI: 10.1111/lam.13134] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 02/07/2019] [Accepted: 02/14/2019] [Indexed: 11/29/2022]
Abstract
The Active Anthrax Detect (AAD) Rapid Test lateral flow immunoassay is a point-of-care assay that was under investigational use for detecting Bacillus anthracis capsular polypeptide (polyglutamic acid) in human blood, serum and plasma. Small sample volumes, rapid results and no refrigeration required allow for easy use in either the field or laboratory. Although the test was developed for use in suspect cases of human inhalation anthrax, its features also make it a potentially powerful tool for testing suspect animal cases. We tested animal tissue samples that were confirmed or ruled out for B. anthracis. The AAD Rapid Tests were also deployed in the field, testing animal carcasses during an anthrax outbreak in hippopotami (Hippopotamus amphibius) and Cape buffalo (Syncerus caffer) in Namibia. Evaluation of all samples showed a specificity of 82% and sensitivity of 98%. However, when the assay was used on specimens from only fresh carcasses (dead for <24 h), the specificity increased to 96%. The AAD Rapid Test is a rapid and simple screening assay, but confirmatory testing needs to be done, especially when the age of the sample (days animal has been deceased) is unknown. SIGNIFICANCE AND IMPACT OF THE STUDY: In countries where anthrax is endemic, many human outbreaks are often caused by epizootics. Earlier detection of infected animals may allow for identification of exposed people, early implementation of prevention and control methods, and ultimately lessen the number of people and animals affected. Detection of Bacillus anthracis in animal tissues using a simple, rapid and field-deployable method would allow for faster outbreak response. We evaluated a simple sample collection and processing method for use with the Active Anthrax Detect Rapid Test lateral flow immunoassay to screen dead animals for anthrax.
Collapse
Affiliation(s)
- C B Kolton
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - C K Marston
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - R A Stoddard
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - C Cossaboom
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - J S Salzer
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| | | | | | - C A Cleveland
- Warnell School of Forestry and Natural Resources, University of Georgia, Athens, GA, USA.,Southeastern Cooperative Wildlife Disease Study, Department of Population Health, College of Veterinary Medicine, University of Georgia, Athens, GA, USA
| | - A T Thompson
- Southeastern Cooperative Wildlife Disease Study, Department of Population Health, College of Veterinary Medicine, University of Georgia, Athens, GA, USA
| | - M F Dalton
- Southeastern Cooperative Wildlife Disease Study, Department of Population Health, College of Veterinary Medicine, University of Georgia, Athens, GA, USA.,Department of Pathology, College of Veterinary Medicine, University of Georgia, Athens, GA, USA
| | - M J Yabsley
- Warnell School of Forestry and Natural Resources, University of Georgia, Athens, GA, USA.,Southeastern Cooperative Wildlife Disease Study, Department of Population Health, College of Veterinary Medicine, University of Georgia, Athens, GA, USA
| | - A R Hoffmaster
- Centers for Disease Control and Prevention, Atlanta, GA, USA
| |
Collapse
|
6
|
Zeptomole per milliliter detection and quantification of edema factor in plasma by LC-MS/MS yields insights into toxemia and the progression of inhalation anthrax. Anal Bioanal Chem 2019; 411:2493-2509. [PMID: 30911800 DOI: 10.1007/s00216-019-01730-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 02/06/2019] [Accepted: 02/26/2019] [Indexed: 12/28/2022]
Abstract
Inhalation of Bacillus anthracis spores can cause a rapidly progressing fatal infection. B. anthracis secretes three protein toxins: lethal factor (LF), edema factor (EF), and protective antigen (PA). EF and LF may circulate as free or PA-bound forms. Both free EF (EF) and PA-bound-EF (ETx) have adenylyl cyclase activity converting ATP to cAMP. We developed an adenylyl cyclase activity-based method for detecting and quantifying total EF (EF+ETx) in plasma. The three-step method includes magnetic immunocapture with monoclonal antibodies, reaction with ATP generating cAMP, and quantification of cAMP by isotope-dilution HPLC-MS/MS. Total EF was quantified from 5PL regression of cAMP vs ETx concentration. The detection limit was 20 fg/mL (225 zeptomoles/mL for the 89 kDa protein). Relative standard deviations for controls with 0.3, 6.0, and 90 pg/mL were 11.7-16.6% with 91.2-99.5% accuracy. The method demonstrated 100% specificity in 238 human serum/plasma samples collected from unexposed healthy individuals, and 100% sensitivity in samples from 3 human and 5 rhesus macaques with inhalation anthrax. Analysis of EF in the rhesus macaques showed that it was detected earlier post-exposure than B. anthracis by culture and PCR. Similar to LF, the kinetics of EF over the course of infection were triphasic, with an initial rise (phase-1), decline (phase-2), and final rapid rise (phase-3). EF levels were ~ 2-4 orders of magnitude lower than LF during phase-1 and phase-2 and only ~ 6-fold lower at death/euthanasia. Analysis of EF improves early diagnosis and adds to our understanding of anthrax toxemia throughout infection. The LF/EF ratio may also indicate the stage of infection and need for advanced treatments.
Collapse
|
7
|
Solano MI, Woolfitt AR, Boyer AE, Lins RC, Isbell K, Gallegos-Candela M, Moura H, Pierce CL, Barr JR. Accurate and selective quantification of anthrax protective antigen in plasma by immunocapture and isotope dilution mass spectrometry. Analyst 2019; 144:2264-2274. [PMID: 30810119 PMCID: PMC7015108 DOI: 10.1039/c8an02479k] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Anthrax protective antigen (83 kDa, PA83) is an essential component of two major binary toxins produced by Bacillus anthracis, lethal toxin (LTx) and edema toxin (ETx). During infection, LTx and ETx contribute to immune collapse, endothelial dysfunction, hemorrhage and high mortality. Following protease cleavage on cell receptors or in circulation, the 20 kDa (PA20) N-terminus is released, activating the 63 kDa (PA63) form which binds lethal factor (LF) and edema factor (EF), facilitating their entry into their cellular targets. Several ELISA-based PA methods previously developed are primarily qualitative or semi-quantitative. Here, we combined protein immunocapture, tryptic digestion and isotope dilution liquid chromatography-mass spectrometry (LC-MS/MS), to develop a highly selective and sensitive method for detection and accurate quantification of total-PA (PA83 + PA63) and PA83. Two tryptic peptides in the 63 kDa region measure total-PA and three in the 20 kDa region measure PA83 alone. Detection limits range from 1.3-2.9 ng mL-1 PA in 100 μL of plasma. Spiked recovery experiments with combinations of PA83, PA63, LF and EF in plasma showed that PA63 and PA83 were quantified accurately against the PA83 standard and that LF and EF did not interfere with accuracy. Applied to a study of inhalation anthrax in rhesus macaques, total-PA suggested triphasic kinetics, similar to that previously observed for LF and EF. This study is the first to report circulating PA83 in inhalation anthrax, typically at less than 4% of the levels of PA63, providing the first evidence that activated PA63 is the primary form of PA throughout infection.
Collapse
Affiliation(s)
- Maria I Solano
- Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Highway, Atlanta, GA 30341, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Content/Potency Assessment of Botulinum Neurotoxin Type-A by Validated Liquid Chromatography Methods and Bioassays. Toxins (Basel) 2019; 11:toxins11010035. [PMID: 30642048 PMCID: PMC6356430 DOI: 10.3390/toxins11010035] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2018] [Revised: 12/28/2018] [Accepted: 01/10/2019] [Indexed: 01/16/2023] Open
Abstract
Botulinum neurotoxin type-A (BoNTA) is one of the seven different serotypes (A to G) produced by Clostridium botulinum. A stability-indicating size-exclusion chromatography (SEC) method was developed and validated, and the specificity was confirmed by forced degradation study, interference of the excipients, and peaks purity. The method was applied to assess the content and high-molecular-weight (HMW) forms of BoNTA in biopharmaceutical products, and the results were compared with those of the LD50 mouse bioassay, the T−47D cell culture assay, and the reversed-phase chromatography (RPC) method, giving mean values of 0.71% higher, 0.36% lower, and 0.87% higher, respectively. Aggregated forms showed significant effects on cytotoxicity, as well as a decrease in the bioactivity (p < 0.05). The employment of the proposed method in conjunction with the optimized analytical technologies for the analysis of the intact and altered forms of the biotechnology-derived medicines, in the correlation studies, enabled the demonstration of the capability of each one of the methods and allowed for great improvements, thereby assuring their safe and effective use.
Collapse
|
9
|
Duracova M, Klimentova J, Fucikova A, Dresler J. Proteomic Methods of Detection and Quantification of Protein Toxins. Toxins (Basel) 2018; 10:toxins10030099. [PMID: 29495560 PMCID: PMC5869387 DOI: 10.3390/toxins10030099] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 02/21/2018] [Accepted: 02/23/2018] [Indexed: 12/11/2022] Open
Abstract
Biological toxins are a heterogeneous group of compounds that share commonalities with biological and chemical agents. Among them, protein toxins represent a considerable, diverse set. They cover a broad range of molecular weights from less than 1000 Da to more than 150 kDa. This review aims to compare conventional detection methods of protein toxins such as in vitro bioassays with proteomic methods, including immunoassays and mass spectrometry-based techniques and their combination. Special emphasis is given to toxins falling into a group of selected agents, according to the Centers for Disease Control and Prevention, such as Staphylococcal enterotoxins, Bacillus anthracis toxins, Clostridium botulinum toxins, Clostridium perfringens epsilon toxin, ricin from Ricinus communis, Abrin from Abrus precatorius or control of trade in dual-use items in the European Union, including lesser known protein toxins such as Viscumin from Viscum album. The analysis of protein toxins and monitoring for biological threats, i.e., the deliberate spread of infectious microorganisms or toxins through water, food, or the air, requires rapid and reliable methods for the early identification of these agents.
Collapse
Affiliation(s)
- Miloslava Duracova
- Faculty of Military Health Sciences, University of Defense in Brno, Třebešská 1575, CZ-500 01 Hradec Králové, Czech Republic.
| | - Jana Klimentova
- Faculty of Military Health Sciences, University of Defense in Brno, Třebešská 1575, CZ-500 01 Hradec Králové, Czech Republic.
| | - Alena Fucikova
- Faculty of Military Health Sciences, University of Defense in Brno, Třebešská 1575, CZ-500 01 Hradec Králové, Czech Republic.
| | - Jiri Dresler
- Military Health Institute, Military Medical Agency, Tychonova 1, CZ-160 00 Prague 6, Czech Republic.
| |
Collapse
|
10
|
Gallegos-Candela M, Boyer AE, Woolfitt AR, Brumlow J, Lins RC, Quinn CP, Hoffmaster AR, Meister G, Barr JR. Validated MALDI-TOF-MS method for anthrax lethal factor provides early diagnosis and evaluation of therapeutics. Anal Biochem 2017; 543:97-107. [PMID: 29224733 PMCID: PMC7904043 DOI: 10.1016/j.ab.2017.12.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 12/01/2017] [Accepted: 12/06/2017] [Indexed: 01/12/2023]
Abstract
Anthrax lethal factor (LF) is a zinc-dependent endoprotease and a critical virulence factor for Bacillus anthracis, the causative agent of anthrax. The mass spectrometry (MS) method for total-LF quantification includes three steps; 1) LF specific antibody capture/concentration, 2) LF-specific hydrolysis of a peptide substrate, and 3) detection and quantification of LF-cleaved peptides by isotope-dilution MALDI-TOF/MS. Recombinant LF spiked plasma was used for calibration and quality control (QC) materials. Specificity was 100% from analysis of serum and plasma from 383 non-infected humans, 31 rabbits, and 24 rhesus macaques. Sensitivity was 100% from 32 human clinical anthrax cases including infections by inhalation, ingestion, cutaneous and injection exposures and experimental infections for 29 rabbits and 24 rhesus macaques with inhalation anthrax. Robustness evaluation included sample storage, serum and plasma, antimicrobial and antitoxin effects and long-term performance. Data from 100 independent runs gave detection limits 0.01 ng/mL (111 amol/mL) for the 4-h method and 0.0027 ng/mL (30 amol/mL) for an alternate 20-h method. QC precision ranged from 7.7 to 14.8% coefficient of variation and accuracy from 0.2 to 9.8% error. The validated LF MS method provides sensitive quantification of anthrax total-LF using a robust high throughput platform for early diagnosis and evaluation of therapeutics during an anthrax emergency.
Collapse
Affiliation(s)
- Maribel Gallegos-Candela
- Centers for Disease Control and Prevention, 4770 Buford Highway Mailstop F-50, Atlanta, GA 30341, USA
| | - Anne E Boyer
- Centers for Disease Control and Prevention, 4770 Buford Highway Mailstop F-50, Atlanta, GA 30341, USA.
| | - Adrian R Woolfitt
- Centers for Disease Control and Prevention, 4770 Buford Highway Mailstop F-50, Atlanta, GA 30341, USA
| | - Judy Brumlow
- Battelle Atlanta Analytical Services, 2987 Clairmont Road NE, Suite 450, Atlanta, GA 30329, USA
| | - Renato C Lins
- Battelle Atlanta Analytical Services, 2987 Clairmont Road NE, Suite 450, Atlanta, GA 30329, USA
| | - Conrad P Quinn
- Centers for Disease Control and Prevention, 1600 Clifton Road, Atlanta, GA 30329, USA
| | - Alex R Hoffmaster
- Centers for Disease Control and Prevention, 1600 Clifton Road, Atlanta, GA 30329, USA
| | - Gabriel Meister
- Battelle Biomedical Research Center, 1425 Plain City Georgesville Rd, West Jefferson, OH 43162, USA
| | - John R Barr
- Centers for Disease Control and Prevention, 4770 Buford Highway Mailstop F-50, Atlanta, GA 30341, USA
| |
Collapse
|
11
|
Evaluation of Combination Drug Therapy for Treatment of Antibiotic-Resistant Inhalation Anthrax in a Murine Model. Antimicrob Agents Chemother 2017; 61:AAC.00788-17. [PMID: 28696235 DOI: 10.1128/aac.00788-17] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2017] [Accepted: 07/02/2017] [Indexed: 12/29/2022] Open
Abstract
Bacillus anthracis is considered a likely agent to be used as a bioweapon, and the use of a strain resistant to the first-line antimicrobial treatments is a concern. We determined treatment efficacies against a ciprofloxacin-resistant strain of B. anthracis (Cipr Ames) in a murine inhalational anthrax model. Ten groups of 46 BALB/c mice were exposed by inhalation to 7 to 35 times the 50% lethal dose (LD50) of B. anthracis Cipr Ames spores. Commencing at 36 h postexposure, groups were administered intraperitoneal doses of sterile water for injections (SWI) and ciprofloxacin alone (control groups), or ciprofloxacin combined with two antimicrobials, including meropenem-linezolid, meropenem-clindamycin, meropenem-rifampin, meropenem-doxycycline, penicillin-linezolid, penicillin-doxycycline, rifampin-linezolid, and rifampin-clindamycin, at appropriate dosing intervals (6 or 12 h) for the respective antibiotics. Ten mice per group were treated for 14 days and observed until day 28. The remaining animals were euthanized every 6 to 12 h, and blood, lungs, and spleens were collected for lethal factor (LF) and/or bacterial load determinations. All combination groups showed significant survival over the SWI and ciprofloxacin controls: meropenem-linezolid (P = 0.004), meropenem-clindamycin (P = 0.005), meropenem-rifampin (P = 0.012), meropenem-doxycycline (P = 0.032), penicillin-doxycycline (P = 0.012), penicillin-linezolid (P = 0.026), rifampin-linezolid (P = 0.001), and rifampin-clindamycin (P = 0.032). In controls, blood, lung, and spleen bacterial counts increased to terminal endpoints. In combination treatment groups, blood and spleen bacterial counts showed low/no colonies after 24-h treatments. The LF fell below the detection limits for all combination groups yet remained elevated in control groups. Combinations with linezolid had the greatest inhibitory effect on mean LF levels.
Collapse
|
12
|
Goldstein JM, Lee J, Tang X, Boyer AE, Barr JR, Bagarozzi DA, Quinn CP. Phage Display Analysis of Monoclonal Antibody Binding to Anthrax Toxin Lethal Factor. Toxins (Basel) 2017. [PMCID: PMC5535168 DOI: 10.3390/toxins9070221] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
AVR1674 and AVR1675 are monoclonal antibodies (mAbs) that bind with high specificity to anthrax toxin lethal factor (LF) and lethal toxin (LTx). These mAbs have been used as pivotal reagents to develop anthrax toxin detection tests using mass spectrometry. The mAbs were demonstrated to bind LF with good affinity (KD 10−7–10−9 M) and to enhance LF-mediated cleavage of synthetic peptide substrates in vitro. Sequence analysis indicated that the mAbs shared 100% amino acid identity in their complementarity determining regions (CDR). A phage display library based on a combinatorial library of random heptapeptides fused to the pIII coat protein of M13 phage was enriched and screened to identify peptide sequences with mAb binding properties. Selection and sequence analysis of 18 anti-LF-reactive phage clones identified a 7-residue (P1–P7) AVR1674/1675 consensus target binding sequence of TP1-XP2-K/RP3-DP4-D/EP5-ZP6-X/ZP7 (X = aromatic, Z = non-polar). The phage peptide sequence with highest affinity binding to AVR1674/1675 was identified as T-F-K-D-E-I-V. Synthetic oligopeptides were designed based on the phage sequences and interacted with mAbs with high affinity (KD ~ 10−9 M). Single amino acid substitutions of A, H, or Q in the peptides identified positions P1–P5 as critical residues for mAb-peptide interactions. CLUSTALW alignment of phage sequences with native LF implicated residues 644–650 (sequence T-H-Q-D-E-I-Y) as a putative linear epitope component located within a structural loop (L2) of LF Domain IV. The activation effects of these mAbs contribute to the analytic sensitivity of function-based LF detection assays.
Collapse
Affiliation(s)
- Jason M. Goldstein
- Reagent and Diagnostic Services Branch, Division of Scientific Resources, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, MS-A03, 1600 Clifton Road, Atlanta, GA 30333, USA; (J.L.); (X.T.); (D.A.B.J.)
- Correspondence: ; Tel.: +1-404-639-2258
| | - Joo Lee
- Reagent and Diagnostic Services Branch, Division of Scientific Resources, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, MS-A03, 1600 Clifton Road, Atlanta, GA 30333, USA; (J.L.); (X.T.); (D.A.B.J.)
| | - Xiaoling Tang
- Reagent and Diagnostic Services Branch, Division of Scientific Resources, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, MS-A03, 1600 Clifton Road, Atlanta, GA 30333, USA; (J.L.); (X.T.); (D.A.B.J.)
| | - Anne E. Boyer
- Clinical Chemistry Branch, Division of Laboratory Services, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy, NE, Atlanta, GA 30341, USA; (A.E.B.); (J.R.B.)
| | - John R. Barr
- Clinical Chemistry Branch, Division of Laboratory Services, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy, NE, Atlanta, GA 30341, USA; (A.E.B.); (J.R.B.)
| | - Dennis A. Bagarozzi
- Reagent and Diagnostic Services Branch, Division of Scientific Resources, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, MS-A03, 1600 Clifton Road, Atlanta, GA 30333, USA; (J.L.); (X.T.); (D.A.B.J.)
| | - Conrad P. Quinn
- Meningitis and Vaccine Preventable Diseases Branch, Division of Bacterial Diseases, National Center for Immunization and Respiratory Diseases, Centers for Disease Control and Prevention, MS-D17, 1600 Clifton Road, Atlanta, GA 30333, USA;
| |
Collapse
|
13
|
Huang E, Pillai SK, Bower WA, Hendricks KA, Guarnizo JT, Hoyle JD, Gorman SE, Boyer AE, Quinn CP, Meaney-Delman D. Antitoxin Treatment of Inhalation Anthrax: A Systematic Review. Health Secur 2016; 13:365-77. [PMID: 26690378 DOI: 10.1089/hs.2015.0032] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Concern about use of anthrax as a bioweapon prompted development of novel anthrax antitoxins for treatment. Clinical guidelines for the treatment of anthrax recommend antitoxin therapy in combination with intravenous antimicrobials; however, a large-scale or mass anthrax incident may exceed antitoxin availability and create a need for judicious antitoxin use. We conducted a systematic review of antitoxin treatment of inhalation anthrax in humans and experimental animals to inform antitoxin recommendations during a large-scale or mass anthrax incident. A comprehensive search of 11 databases and the FDA website was conducted to identify relevant animal studies and human reports: 28 animal studies and 3 human cases were identified. Antitoxin monotherapy at or shortly after symptom onset demonstrates increased survival compared to no treatment in animals. With early treatment, survival did not differ between antimicrobial monotherapy and antimicrobial-antitoxin therapy in nonhuman primates and rabbits. With delayed treatment, antitoxin-antimicrobial treatment increased rabbit survival. Among human cases, addition of antitoxin to combination antimicrobial treatment was associated with survival in 2 of the 3 cases treated. Despite the paucity of human data, limited animal data suggest that adjunctive antitoxin therapy may improve survival. Delayed treatment studies suggest improved survival with combined antitoxin-antimicrobial therapy, although a survival difference compared with antimicrobial therapy alone was not demonstrated statistically. In a mass anthrax incident with limited antitoxin supplies, antitoxin treatment of individuals who have not demonstrated a clinical benefit from antimicrobials, or those who present with more severe illness, may be warranted. Additional pathophysiology studies are needed, and a point-of-care assay correlating toxin levels with clinical status may provide important information to guide antitoxin use during a large-scale anthrax incident.
Collapse
|
14
|
In vivo dynamics of active edema and lethal factors during anthrax. Sci Rep 2016; 6:23346. [PMID: 26996161 PMCID: PMC4800402 DOI: 10.1038/srep23346] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Accepted: 02/26/2016] [Indexed: 01/21/2023] Open
Abstract
Lethal and edema toxins are critical virulence factors of Bacillus anthracis. However, little is known about their in vivo dynamics of production during anthrax. In this study, we unraveled for the first time the in vivo kinetics of production of the toxin components EF (edema factor) and LF (lethal factor) during cutaneous infection with a wild-type toxinogenic encapsulated strain in immuno-competent mice. We stratified the asynchronous infection process into defined stages through bioluminescence imaging (BLI), while exploiting sensitive quantitative methods by measuring the enzymatic activity of LF and EF. LF was produced in high amounts, while EF amounts steadily increased during the infectious process. This led to high LF/EF ratios throughout the infection, with variations between 50 to a few thousands. In the bloodstream, the early detection of active LF and EF despite the absence of bacteria suggests that they may exert long distance effects. Infection with a strain deficient in the protective antigen toxin component enabled to address its role in the diffusion of LF and EF within the host. Our data provide a picture of the in vivo complexity of the infectious process.
Collapse
|
15
|
Duriez E, Armengaud J, Fenaille F, Ezan E. Mass spectrometry for the detection of bioterrorism agents: from environmental to clinical applications. JOURNAL OF MASS SPECTROMETRY : JMS 2016; 51:183-199. [PMID: 26956386 DOI: 10.1002/jms.3747] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Revised: 12/14/2015] [Accepted: 01/13/2016] [Indexed: 06/05/2023]
Abstract
In the current context of international conflicts and localized terrorist actions, there is unfortunately a permanent threat of attacks with unconventional warfare agents. Among these, biological agents such as toxins, microorganisms, and viruses deserve particular attention owing to their ease of production and dissemination. Mass spectrometry (MS)-based techniques for the detection and quantification of biological agents have a decisive role to play for countermeasures in a scenario of biological attacks. The application of MS to every field of both organic and macromolecular species has in recent years been revolutionized by the development of soft ionization techniques (MALDI and ESI), and by the continuous development of MS technologies (high resolution, accurate mass HR/AM instruments, novel analyzers, hybrid configurations). New possibilities have emerged for exquisite specific and sensitive detection of biological warfare agents. MS-based strategies for clinical application can now address a wide range of analytical questions mainly including issues related to the complexity of biological samples and their available volume. Multiplexed toxin detection, discovery of new markers through omics approaches, and identification of untargeted microbiological or of novel molecular targets are examples of applications. In this paper, we will present these technological advances along with the novel perspectives offered by omics approaches to clinical detection and follow-up.
Collapse
Affiliation(s)
| | - Jean Armengaud
- CEA, iBiTec-S, Service de Pharmacologie et d'Immunologie, 30207, Bagnols sur-Cèze, France
| | - François Fenaille
- CEA, iBiTec-S, Service de Pharmacologie et d'Immunoanalyse, Laboratoire d'Etude du Métabolisme des Médicaments, MetaboHUB-Paris, CEA Saclay, Building 136, 91191, Gif-sur-Yvette cedex, France
| | - Eric Ezan
- CEA, Programme Transversal Technologies pour la Santé, 91191, Gif sur Yvette, France
| |
Collapse
|
16
|
Kolesnikov AV, Kozyr AV, Ryabko AK, Shemyakin IG. Ultrasensitive detection of protease activity of anthrax and botulinum toxins by a new PCR-based assay. Pathog Dis 2015; 74:ftv112. [PMID: 26620058 DOI: 10.1093/femspd/ftv112] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/24/2015] [Indexed: 11/14/2022] Open
Abstract
Anthrax and botulism are dangerous infectious diseases that can be fatal unless detected and treated quickly. Fatalities from these diseases are primarily due to endopeptidase toxins secreted by the pathogens. Rapid and sensitive detection of the presence of active toxins is the key element for protection from natural outbreaks of anthrax and botulism, as well as from the threat of bioterrorism. We describe an ultrasensitive polymerase chain reaction (PCR)-based assay for detecting proteolytic activity of anthrax and botulinum toxins using composite probes consisting of covalent peptide-DNA conjugate for the detection of anthrax, and noncovalent protein-aptamer assembly to assay botulinum toxin activity. Probes immobilized on the solid-phase support are cleaved by toxins to release DNA, which is detected by real-time PCR. Both assays can detect subpicogram quantities of active toxins isolated from composite matrices. Special procedures were developed to isolate intact toxins from the matrices under mild conditions. The assay is rapid, uses proven technologies, and can be modified to detect other proteolytic and biopolymer-degrading enzymes.
Collapse
Affiliation(s)
- Alexander V Kolesnikov
- State Research Center for Applied Microbiology and Biotechnology, Obolensk, Moscow Region 142279, Russia Institute of Immunological Engineering, Lyubuchany, Moscow Region 142380, Russia
| | - Arina V Kozyr
- State Research Center for Applied Microbiology and Biotechnology, Obolensk, Moscow Region 142279, Russia
| | - Alyona K Ryabko
- State Research Center for Applied Microbiology and Biotechnology, Obolensk, Moscow Region 142279, Russia
| | - Igor G Shemyakin
- State Research Center for Applied Microbiology and Biotechnology, Obolensk, Moscow Region 142279, Russia
| |
Collapse
|
17
|
Dupré M, Gilquin B, Fenaille F, Feraudet-Tarisse C, Dano J, Ferro M, Simon S, Junot C, Brun V, Becher F. Multiplex Quantification of Protein Toxins in Human Biofluids and Food Matrices Using Immunoextraction and High-Resolution Targeted Mass Spectrometry. Anal Chem 2015; 87:8473-80. [DOI: 10.1021/acs.analchem.5b01900] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Mathieu Dupré
- CEA, DSV, iBiTec-S, Laboratoire d’études
du métabolisme des médicaments, 91191 Gif-sur-Yvette, France
| | - Benoit Gilquin
- Université
Grenoble Alpes, iRTSV-BGE, F-38000 Grenoble, France
- CEA, iRTSV-BGE, F-38000 Grenoble, France
- INSERM, BGE, F-38000 Grenoble, France
| | - François Fenaille
- CEA, DSV, iBiTec-S, Laboratoire d’études
du métabolisme des médicaments, 91191 Gif-sur-Yvette, France
| | - Cécile Feraudet-Tarisse
- CEA, DSV, iBiTec-S, Laboratoire d’études
et de recherches en immunoanalyse, 91191 Gif-sur-Yvette, France
| | - Julie Dano
- CEA, DSV, iBiTec-S, Laboratoire d’études
et de recherches en immunoanalyse, 91191 Gif-sur-Yvette, France
| | - Myriam Ferro
- Université
Grenoble Alpes, iRTSV-BGE, F-38000 Grenoble, France
- CEA, iRTSV-BGE, F-38000 Grenoble, France
- INSERM, BGE, F-38000 Grenoble, France
| | - Stéphanie Simon
- CEA, DSV, iBiTec-S, Laboratoire d’études
et de recherches en immunoanalyse, 91191 Gif-sur-Yvette, France
| | - Christophe Junot
- CEA, DSV, iBiTec-S, Laboratoire d’études
du métabolisme des médicaments, 91191 Gif-sur-Yvette, France
| | - Virginie Brun
- Université
Grenoble Alpes, iRTSV-BGE, F-38000 Grenoble, France
- CEA, iRTSV-BGE, F-38000 Grenoble, France
- INSERM, BGE, F-38000 Grenoble, France
| | - François Becher
- CEA, DSV, iBiTec-S, Laboratoire d’études
du métabolisme des médicaments, 91191 Gif-sur-Yvette, France
| |
Collapse
|
18
|
Rosen O, Feldberg L, Gura S, Zichel R. A new peptide substrate for enhanced botulinum neurotoxin type B detection by endopeptidase–liquid chromatography–tandem mass spectrometry/multiple reaction monitoring assay. Anal Biochem 2015; 473:7-10. [DOI: 10.1016/j.ab.2014.09.016] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2014] [Revised: 09/21/2014] [Accepted: 09/22/2014] [Indexed: 10/24/2022]
|
19
|
High-sensitivity MALDI-TOF MS quantification of anthrax lethal toxin for diagnostics and evaluation of medical countermeasures. Anal Bioanal Chem 2015; 407:2847-58. [PMID: 25673244 PMCID: PMC4369318 DOI: 10.1007/s00216-015-8509-5] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2014] [Revised: 01/13/2015] [Accepted: 01/21/2015] [Indexed: 11/15/2022]
Abstract
Inhalation anthrax has a rapid progression and high fatality rate. Pathology and death from inhalation of Bacillus anthracis spores are attributed to the actions of secreted protein toxins. Protective antigen (PA) binds and imports the catalytic component lethal factor (LF), a zinc endoprotease, and edema factor (EF), an adenylyl cyclase, into susceptible cells. PA-LF is termed lethal toxin (LTx) and PA-EF, edema toxin. As the universal transporter for both toxins, PA is an important target for vaccination and immunotherapeutic intervention. However, its quantification has been limited to methods of relatively low analytic sensitivity. Quantification of LTx may be more clinically relevant than LF or PA alone because LTx is the toxic form that acts on cells. A method was developed for LTx-specific quantification in plasma using anti-PA IgG magnetic immunoprecipitation of PA and quantification of LF activity that co-purified with PA. The method was fast (<4 h total time to detection), sensitive at 0.033 ng/mL LTx in plasma for the fast analysis (0.0075 ng/mL LTx in plasma for an 18 h reaction), precise (6.3–9.9 % coefficient of variation), and accurate (0.1–12.7 %error; n ≥ 25). Diagnostic sensitivity was 100 % (n = 27 animal/clinical cases). Diagnostic specificity was 100 % (n = 141). LTx was detected post-antibiotic treatment in 6/6 treated rhesus macaques and 3/3 clinical cases of inhalation anthrax and as long as 8 days post-treatment. Over the course of infection in two rhesus macaques, LTx was first detected at 0.101 and 0.237 ng/mL at 36 h post-exposure and increased to 1147 and 12,107 ng/mL in late-stage anthrax. This demonstrated the importance of LTx as a diagnostic and therapeutic target. This method provides a sensitive, accurate tool for anthrax toxin detection and evaluation of PA-directed therapeutics. Method schematic for analysis of anthrax lethal toxin activity by ID-MALDI-TOF MS ![]()
Collapse
|
20
|
Jenko KL, Zhang Y, Kostenko Y, Fan Y, Garcia-Rodriguez C, Lou J, Marks JD, Varnum SM. Development of an ELISA microarray assay for the sensitive and simultaneous detection of ten biodefense toxins. Analyst 2014; 139:5093-102. [PMID: 25112421 PMCID: PMC6540756 DOI: 10.1039/c4an01270d] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Plant and microbial toxins are considered bioterrorism threat agents because of their extreme toxicity and/or ease of availability. Additionally, some of these toxins are increasingly responsible for accidental food poisonings. The current study utilized an ELISA-based protein antibody microarray for the multiplexed detection of ten biothreat toxins, botulinum neurotoxins (BoNT) A, B, C, D, E, F, ricin, shiga toxins 1 and 2 (Stx), and staphylococcus enterotoxin B (SEB), in buffer and complex biological matrices. The multiplexed assay displayed a sensitivity of 1.3 pg mL(-1) (BoNT/A, BoNT/B, SEB, Stx-1 and Stx-2), 3.3 pg mL(-1) (BoNT/C, BoNT/E, BoNT/F) and 8.2 pg mL(-1) (BoNT/D, ricin). All assays demonstrated high accuracy (75-120 percent recovery) and reproducibility (most coefficients of variation <20%). Quantification curves for the ten toxins were also evaluated in clinical samples (serum, plasma, nasal fluid, saliva, stool, and urine) and environmental samples (apple juice, milk and baby food) with overall minimal matrix effects. The multiplex assays were highly specific, with little cross-reactivity observed between the selected toxin antibodies. The results demonstrate a multiplex microarray that improves current immunoassay sensitivity for biological warfare agents in buffer, clinical, and environmental samples.
Collapse
Affiliation(s)
- Kathryn L Jenko
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99354, USA.
| | | | | | | | | | | | | | | |
Collapse
|
21
|
Sprenkle MD, Griffith J, Marinelli W, Boyer AE, Quinn CP, Pesik NT, Hoffmaster A, Keenan J, Juni BA, Blaney DD. Lethal factor and anti-protective antigen IgG levels associated with inhalation anthrax, Minnesota, USA. Emerg Infect Dis 2014; 20:310-4. [PMID: 24447456 PMCID: PMC3901492 DOI: 10.3201/eid2002.130245] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Bacillus anthracis was identified in a 61-year-old man hospitalized in Minnesota, USA. Cooperation between the hospital and the state health agency enhanced prompt identification of the pathogen. Treatment comprising antimicrobial drugs, anthrax immune globulin, and pleural drainage led to full recovery; however, the role of passive immunization in anthrax treatment requires further evaluation.
Collapse
|
22
|
Detection of anthrax protective antigen (PA) using europium labeled anti-PA monoclonal antibody and time-resolved fluorescence. J Immunol Methods 2014; 408:78-88. [PMID: 24857756 DOI: 10.1016/j.jim.2014.05.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2014] [Revised: 05/05/2014] [Accepted: 05/07/2014] [Indexed: 11/22/2022]
Abstract
Inhalation anthrax is a rare but acute infectious disease following adsorption of Bacillus anthracis spores through the lungs. The disease has a high fatality rate if untreated, but early and correct diagnosis has a significant impact on case patient recovery. The early symptoms of inhalation anthrax are, however, non-specific and current anthrax diagnostics are primarily dependent upon culture and confirmatory real-time PCR. Consequently, there may be a significant delay in diagnosis and targeted treatment. Rapid, culture-independent diagnostic tests are therefore needed, particularly in the context of a large scale emergency response. The aim of this study was to evaluate the ability of monoclonal antibodies to detect anthrax toxin proteins that are secreted early in the course of B. anthracis infection using a time-resolved fluorescence (TRF) immunoassay. We selected monoclonal antibodies that could detect protective antigen (PA), as PA83 and also PA63 and LF in the lethal toxin complex. The assay reliable detection limit (RDL) was 6.63×10(-6)μM (0.551ng/ml) for PA83 and 2.51×10(-5)μM (1.58ng/ml) for PA63. Despite variable precision and accuracy of the assay, PA was detected in 9 out of 10 sera samples from anthrax confirmed case patients with cutaneous (n=7), inhalation (n=2), and gastrointestinal (n=1) disease. Anthrax Immune Globulin (AIG), which has been used in treatment of clinical anthrax, interfered with detection of PA. This study demonstrates a culture-independent method of diagnosing anthrax through the use of monoclonal antibodies to detect PA and LF in the lethal toxin complex.
Collapse
|
23
|
Abstract
The aim of this work was to present selected data regarding traditional and modern methods for C. botulinum and its toxins detection. In this article, methods based on culturing techniques, mouse bioassay, immunological techniques, chromatography and PCR, PFGE, RFLP, AFLP are described. The mentioned techniques were evaluated considering their usefulness in the samples examination, genotyping of strains and the diagnostics of botulism.
Collapse
|
24
|
Rosen O, Feldberg L, Gura S, Zichel R. Improved detection of botulinum type E by rational design of a new peptide substrate for endopeptidase-mass spectrometry assay. Anal Biochem 2014; 456:50-2. [PMID: 24721293 DOI: 10.1016/j.ab.2014.03.024] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2014] [Revised: 03/26/2014] [Accepted: 03/29/2014] [Indexed: 12/01/2022]
Abstract
Botulinum neurotoxins (BoNTs) are the most toxic substances known to humans. Endopeptidase-mass spectrometry (Endopep-MS) is used as a specific and rapid in vitro assay to detect BoNTs. In this assay, immunocaptured toxin cleaves a serotype-specific peptide substrate, and the cleavage products are then detected by MS. To further improve the sensitivity of the assay, we report here the rational design of a new substrate peptide for the detection of botulinum neurotoxin type E (BoNT/E). Our strategy was based on previously reported structural interactions integrated with analysis method efficiency considerations. Integration of the newly designed substrate has led to a more than one order of magnitude increased sensitivity of the assay.
Collapse
Affiliation(s)
- Osnat Rosen
- Department of Biotechnology, Israel Institute for Biological Research, Ness Ziona 7410001, Israel
| | - Liron Feldberg
- Department of Analytical Chemistry, Israel Institute for Biological Research, Ness Ziona 7410001, Israel
| | - Sigalit Gura
- Department of Analytical Chemistry, Israel Institute for Biological Research, Ness Ziona 7410001, Israel
| | - Ran Zichel
- Department of Biotechnology, Israel Institute for Biological Research, Ness Ziona 7410001, Israel.
| |
Collapse
|
25
|
Tevell Åberg A, Björnstad K, Hedeland M. Mass Spectrometric Detection of Protein-Based Toxins. Biosecur Bioterror 2013; 11 Suppl 1:S215-26. [DOI: 10.1089/bsp.2012.0072] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Affiliation(s)
- Annica Tevell Åberg
- Annica Tevell Åberg, PhD, is a Senior Researcher; Kristian Björnstad, PhD, is a Senior Researcher; and Mikael Hedeland, PhD, is an Associate Professor and Deputy Head of Department; all at the Department of Chemistry, Environment and Feed Hygiene, National Veterinary Institute (SVA), Uppsala, Sweden. Dr. Åberg and Dr. Hedeland are also affiliated with the Division of Analytical Pharmaceutical Chemistry, Uppsala University, Uppsala, Sweden
| | - Kristian Björnstad
- Annica Tevell Åberg, PhD, is a Senior Researcher; Kristian Björnstad, PhD, is a Senior Researcher; and Mikael Hedeland, PhD, is an Associate Professor and Deputy Head of Department; all at the Department of Chemistry, Environment and Feed Hygiene, National Veterinary Institute (SVA), Uppsala, Sweden. Dr. Åberg and Dr. Hedeland are also affiliated with the Division of Analytical Pharmaceutical Chemistry, Uppsala University, Uppsala, Sweden
| | - Mikael Hedeland
- Annica Tevell Åberg, PhD, is a Senior Researcher; Kristian Björnstad, PhD, is a Senior Researcher; and Mikael Hedeland, PhD, is an Associate Professor and Deputy Head of Department; all at the Department of Chemistry, Environment and Feed Hygiene, National Veterinary Institute (SVA), Uppsala, Sweden. Dr. Åberg and Dr. Hedeland are also affiliated with the Division of Analytical Pharmaceutical Chemistry, Uppsala University, Uppsala, Sweden
| |
Collapse
|
26
|
Proteomic Analysis and Label-Free Quantification of the Large Clostridium difficile Toxins. INTERNATIONAL JOURNAL OF PROTEOMICS 2013; 2013:293782. [PMID: 24066231 PMCID: PMC3771451 DOI: 10.1155/2013/293782] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/12/2013] [Revised: 06/23/2013] [Accepted: 06/24/2013] [Indexed: 01/05/2023]
Abstract
Clostridium difficile is the leading cause of antibiotic-associated diarrhea in hospitals worldwide, due to hypervirulent epidemic strains with the ability to produce increased quantities of the large toxins TcdA and TcdB. Unfortunately, accurate quantification of TcdA and TcdB from different toxinotypes using small samples has not yet been reported. In the present study, we quantify C. difficile toxins in <0.1 mL of culture filtrate by quantitative label-free mass spectrometry (MS) using data-independent analysis (MSE). In addition, analyses of both purified TcdA and TcdB as well as a standard culture filtrate were performed using gel-based and gel-independent proteomic platforms. Gel-based proteomic analysis was then used to generate basic information on toxin integrity and provided sequence confirmation. Gel-independent in-solution digestion of both toxins using five different proteolytic enzymes with MS analysis generated broad amino acid sequence coverage (91% for TcdA and 95% for TcdB). Proteomic analysis of a culture filtrate identified a total of 101 proteins, among them TcdA, TcdB, and S-layer proteins.
Collapse
|
27
|
Luo S, Li T, Wang Q, Tian R, Liu H, Fang H, Chen F, Wang H. Development of a fusion protein SNVP as substrate for assaying multi-serotype botulinum neurotoxins. Anal Biochem 2013; 463:75-81. [PMID: 23851341 DOI: 10.1016/j.ab.2013.06.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Revised: 06/19/2013] [Accepted: 06/24/2013] [Indexed: 10/26/2022]
Abstract
The SNARE super family has three core members, namely SNAP-25, VAMP-2, and syntaxin. SNAP-25 is cleaved by botulinum toxins (BoNTs)/A, /C, and /E, whereas VAMP-2 is the substrate for proteolytic BoNTs/B, /D, /F, and /G. In this study, we constructed a hybrid gene encoding the fusion protein SNVP that encompasses SNAP-25 residues Met1 to Gly206 and VAMP-2 residues Met1 to Lys94. The hybrid gene was cloned in a prokaryotic vector carrying an N-terminal pelB signal sequence and overexpressed in Escherichia coli BL21(DE3) Rosetta. To easily purify the protein, 6× His double-affinity tags were designed as the linker and C terminus of the fusion protein. SNVP was purified to homogeneity by affinity chromatography on a HisTrap FF column and determined to be more than 97% pure by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. N-terminal sequencing of the purified protein showed that signal peptide was successfully removed. The fusion protein SNVP contained the protease cleavage sites of all seven serotypes of BoNTs. SNVP was also proved to be recognized and cleaved by the endopeptidase of BoNTs (BoNT/A-LC, BoNT/B-LC, BoNT/E-LC, and BoNT/G-LC). The novel fusion substrate SNVP exhibited high biological activity under the optimal conditions, suggesting its potential use as a reagent for BoNT assay.
Collapse
Affiliation(s)
- Sen Luo
- State Key Laboratory of Pathogens and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing 100071, PR China; Department of Microbiology, An Hui Medical University, An Hui 230032, PR China
| | - Tao Li
- State Key Laboratory of Pathogens and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing 100071, PR China
| | - Qin Wang
- State Key Laboratory of Pathogens and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing 100071, PR China
| | - Renmao Tian
- State Key Laboratory of Pathogens and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing 100071, PR China
| | - Hao Liu
- State Key Laboratory of Pathogens and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing 100071, PR China
| | - Huali Fang
- State Key Laboratory of Pathogens and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing 100071, PR China
| | - Fanghong Chen
- State Key Laboratory of Pathogens and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing 100071, PR China
| | - Hui Wang
- State Key Laboratory of Pathogens and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing 100071, PR China.
| |
Collapse
|
28
|
Rodríguez-Pardo D, Mirelis B, Navarro F. Infecciones producidas por Clostridium difficile. Enferm Infecc Microbiol Clin 2013; 31:254-63. [DOI: 10.1016/j.eimc.2012.12.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Accepted: 12/13/2012] [Indexed: 01/05/2023]
|
29
|
Current status of matrix-assisted laser desorption ionisation-time of flight mass spectrometry in the clinical microbiology laboratory. Pathology 2013; 45:4-17. [DOI: 10.1097/pat.0b013e32835be408] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
30
|
Wang D, Baudys J, Ye Y, Rees JC, Barr JR, Pirkle JL, Kalb SR. Improved detection of botulinum neurotoxin serotype A by Endopep-MS through peptide substrate modification. Anal Biochem 2012; 432:115-23. [PMID: 23017875 DOI: 10.1016/j.ab.2012.09.021] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2012] [Revised: 09/10/2012] [Accepted: 09/17/2012] [Indexed: 11/16/2022]
Abstract
Botulinum neurotoxins (BoNTs) are a family of seven toxin serotypes that are the most toxic substances known to humans. Intoxication with BoNT causes flaccid paralysis and can lead to death if untreated with serotype-specific antibodies. Supportive care, including ventilation, may be necessary. Rapid and sensitive detection of BoNT is necessary for timely clinical confirmation of clinical botulism. Previously, our laboratory developed a fast and sensitive mass spectrometry (MS) method termed the Endopep-MS assay. The BoNT serotypes are rapidly detected and differentiated by extracting the toxin with serotype-specific antibodies and detecting the unique and serotype-specific cleavage products of peptide substrates that mimic the sequence of the BoNT native targets. To further improve the sensitivity of the Endopep-MS assay, we report here the optimization of the substrate peptide for the detection of BoNT/A. Modifications on the terminal groups of the original peptide substrate with acetylation and amidation significantly improved the detection of BoNT/A cleavage products. The replacement of some internal amino acid residues with single or multiple substitutions led to further improvement. An optimized peptide increased assay sensitivity 5-fold with toxin spiked into buffer solution or different biological matrices.
Collapse
Affiliation(s)
- Dongxia Wang
- National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA
| | | | | | | | | | | | | |
Collapse
|
31
|
Tsilia V, Devreese B, de Baenst I, Mesuere B, Rajkovic A, Uyttendaele M, Van de Wiele T, Heyndrickx M. Application of MALDI-TOF mass spectrometry for the detection of enterotoxins produced by pathogenic strains of the Bacillus cereus group. Anal Bioanal Chem 2012; 404:1691-702. [PMID: 22875537 DOI: 10.1007/s00216-012-6254-6] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2012] [Revised: 07/03/2012] [Accepted: 07/09/2012] [Indexed: 11/28/2022]
Abstract
Enterotoxins produced by different species of the Bacillus cereus group, such as cytotoxin K1 (CytK1) and non-haemolytic enterotoxin (NHE), have been associated with diarrhoeal food poisoning incidents. Detection of CytK1 is not possible with commercial assays while NHE is recognised by an immunological kit (TECRA) that does not specifically target this protein because it is based on polyclonal antibodies. It is evident that the lack of suitable tools for the study of enterotoxins hampers the possibilities for accurate hazard identification and characterisation in microbial food safety risk assessment. We applied matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF/MS) for the detection of CytK1 and NHE produced by pathogenic strains of the B. cereus group using protein digests from 1D gel electrophoresis. Secretion of CytK1 and two of the three components of NHE was confirmed in supernatants of different B. cereus cultures. For each protein, we introduce biomarkers that could be used for the screening of food poisoning or food/environmental isolates that can secrete enterotoxins. For example, tryptic peptides of 2,310.2 and 1,192.5 Da (calculated mass) can be indicators for CytK1 and NheA, respectively, although a simultaneous detection of other enterotoxin-specific peptides is recommended to assure the presence of a toxin in an unknown sample. Comparison of MALDI-TOF/MS with the TECRA kit showed that our methodological strategy performed well and it had the competitive advantage of specifically detecting NheA. Therefore, MALDI-TOF/MS can be successfully incorporated into risk assessment procedures in order to determine the involvement of strains of the B. cereus group in foodborne outbreaks, including the recently described cytK1 producing species, Bacillus cytotoxicus.
Collapse
Affiliation(s)
- Varvara Tsilia
- Laboratory for Protein Biochemistry and Biomolecular Engineering (L-PROBE), Department of Biochemistry and Microbiology, Ghent University, Ghent, Belgium
| | | | | | | | | | | | | | | |
Collapse
|
32
|
Dragan AI, Albrecht MT, Pavlovic R, Keane-Myers AM, Geddes CD. Ultra-fast pg/ml anthrax toxin (protective antigen) detection assay based on microwave-accelerated metal-enhanced fluorescence. Anal Biochem 2012; 425:54-61. [DOI: 10.1016/j.ab.2012.02.040] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2011] [Revised: 02/28/2012] [Accepted: 02/29/2012] [Indexed: 02/07/2023]
|
33
|
Antibodies against a synthetic peptide designed to mimic a surface area of the H chain of botulinum neurotoxin A. Immunol Lett 2012; 142:20-7. [DOI: 10.1016/j.imlet.2011.11.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2011] [Revised: 11/07/2011] [Accepted: 11/14/2011] [Indexed: 11/23/2022]
|
34
|
Rapid detection methods for Bacillus anthracis in environmental samples: a review. Appl Microbiol Biotechnol 2012; 93:1411-22. [DOI: 10.1007/s00253-011-3845-7] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2011] [Revised: 12/12/2011] [Accepted: 12/14/2011] [Indexed: 12/11/2022]
|
35
|
Dorner MB, Schulz KM, Kull S, Dorner BG. Complexity of Botulinum Neurotoxins: Challenges for Detection Technology. Curr Top Microbiol Immunol 2012. [DOI: 10.1007/978-3-662-45790-0_11] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
36
|
Boyer AE, Quinn CP, Beesley CA, Gallegos-Candela M, Marston CK, Cronin LX, Lins RC, Stoddard RA, Li H, Schiffer J, Hossain MJ, Chakraborty A, Rahman M, Luby SP, Shieh WJ, Zaki S, Barr JR, Hoffmaster AR. Lethal factor toxemia and anti-protective antigen antibody activity in naturally acquired cutaneous anthrax. J Infect Dis 2011; 204:1321-7. [PMID: 21908727 PMCID: PMC3182309 DOI: 10.1093/infdis/jir543] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Cutaneous anthrax outbreaks occurred in Bangladesh from August to October 2009. As part of the epidemiological response and to confirm anthrax diagnoses, serum samples were collected from suspected case patients with observed cutaneous lesions. Anthrax lethal factor (LF), anti-protective antigen (anti-PA) immunoglobulin G (IgG), and anthrax lethal toxin neutralization activity (TNA) levels were determined in acute and convalescent serum of 26 case patients with suspected cutaneous anthrax from the first and largest of these outbreaks. LF (0.005-1.264 ng/mL) was detected in acute serum from 18 of 26 individuals. Anti-PA IgG and TNA were detected in sera from the same 18 individuals and ranged from 10.0 to 679.5 μg/mL and 27 to 593 units, respectively. Seroconversion to serum anti-PA and TNA was found only in case patients with measurable toxemia. This is the first report of quantitative analysis of serum LF in cutaneous anthrax and the first to associate acute stage toxemia with subsequent antitoxin antibody responses.
Collapse
Affiliation(s)
- Anne E Boyer
- Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|