1
|
Hussain M, He X, Wang C, Wang Y, Wang J, Chen M, Kang H, Yang N, Ni X, Li J, Zhou X, Liu B. Recent advances in microfluidic-based spectroscopic approaches for pathogen detection. BIOMICROFLUIDICS 2024; 18:031505. [PMID: 38855476 PMCID: PMC11162289 DOI: 10.1063/5.0204987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 05/30/2024] [Indexed: 06/11/2024]
Abstract
Rapid identification of pathogens with higher sensitivity and specificity plays a significant role in maintaining public health, environmental monitoring, controlling food quality, and clinical diagnostics. Different methods have been widely used in food testing laboratories, quality control departments in food companies, hospitals, and clinical settings to identify pathogens. Some limitations in current pathogens detection methods are time-consuming, expensive, and laborious sample preparation, making it unsuitable for rapid detection. Microfluidics has emerged as a promising technology for biosensing applications due to its ability to precisely manipulate small volumes of fluids. Microfluidics platforms combined with spectroscopic techniques are capable of developing miniaturized devices that can detect and quantify pathogenic samples. The review focuses on the advancements in microfluidic devices integrated with spectroscopic methods for detecting bacterial microbes over the past five years. The review is based on several spectroscopic techniques, including fluorescence detection, surface-enhanced Raman scattering, and dynamic light scattering methods coupled with microfluidic platforms. The key detection principles of different approaches were discussed and summarized. Finally, the future possible directions and challenges in microfluidic-based spectroscopy for isolating and detecting pathogens using the latest innovations were also discussed.
Collapse
Affiliation(s)
| | - Xu He
- Engineering Research Center of Intelligent Theranostics Technology and Instruments, Ministry of Education, School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
| | - Chao Wang
- Engineering Research Center of Intelligent Theranostics Technology and Instruments, Ministry of Education, School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
| | - Yichuan Wang
- Engineering Research Center of Intelligent Theranostics Technology and Instruments, Ministry of Education, School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
| | - Jingjing Wang
- Engineering Research Center of Intelligent Theranostics Technology and Instruments, Ministry of Education, School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
| | - Mingyue Chen
- Engineering Research Center of Intelligent Theranostics Technology and Instruments, Ministry of Education, School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, China
| | - Haiquan Kang
- Department of Laboratory Medicine, Affiliated Hospital of Xuzhou Medical University, Xuzhou 221002, China
| | | | - Xinye Ni
- The Affiliated Changzhou Second People’s Hospital of Nanjing Medical University, Changzhou Second People's Hospital, Changzhou Medical Center, Nanjing Medical University, Changzhou 213161, China
| | | | - Xiuping Zhou
- Department of Laboratory Medicine, The Peoples Hospital of Rugao, Rugao Hospital Affiliated to Nantong University, Nantong 226500, China
| | - Bin Liu
- Author to whom correspondence should be addressed:
| |
Collapse
|
2
|
Muraoka A, Yokoi A, Kajiyama H. Emerging bacterial factors for understanding pathogenesis of endometriosis. iScience 2024; 27:108739. [PMID: 38269103 PMCID: PMC10805679 DOI: 10.1016/j.isci.2023.108739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2024] Open
Abstract
The pathogenesis of endometriosis is a complex process, and recent research has introduced novel hypotheses in this field. This review summarizes recent studies on the pathogenesis of endometriosis. We focused on several classical hypotheses, as well as their interactions with the microenvironment of hormonal dependence and immunosuppression. Furthermore, we highlighted the emergence of bacterial factors associated with endometriosis. Recent advances in next-generation sequencing (NGS) have revealed the presence and detailed distribution of these bacteria as well as the involvement of specific bacteria in pathogenesis. These factors alter the microenvironment in the early stages of endometriosis development, leading to lesion formation. Understanding the mechanisms underlying the early development of endometriosis from a new perspective would be helpful for the development of novel therapeutic agents for endometriosis.
Collapse
Affiliation(s)
- Ayako Muraoka
- Department of Obstetrics and Gynecology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan
| | - Akira Yokoi
- Department of Obstetrics and Gynecology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan
- Nagoya University Institute for Advanced Research, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
- Japan Science and Technology Agency (JST), FOREST, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012, Japan
| | - Hiroaki Kajiyama
- Department of Obstetrics and Gynecology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan
| |
Collapse
|
3
|
Patil AVP, Yang PF, Yang CY, Gaur MS, Wu CC. A Critical Review on Detection of Foodborne Pathogens Using Electrochemical Biosensors. Crit Rev Biomed Eng 2024; 52:17-40. [PMID: 38523439 DOI: 10.1615/critrevbiomedeng.2023049469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2024]
Abstract
An outbreak of foodborne pathogens would cause severe consequences. Detecting and diagnosing foodborne diseases is crucial for food safety, and it is increasingly important to develop fast, sensitive, and cost-effective methods for detecting foodborne pathogens. In contrast to traditional methods, such as medium-based culture, nucleic acid amplification test, and enzyme-linked immunosorbent assay, electrochemical biosensors possess the advantages of simplicity, rapidity, high sensitivity, miniaturization, and low cost, making them ideal for developing pathogen-sensing devices. The biorecognition layer, consisting of recognition elements, such as aptamers, antibodies and bacteriophages, and other biomolecules or polymers, is the most critical component to determine the selectivity, specificity, reproducibility, and lifetime of a biosensor when detecting pathogens in a biosample. Furthermore, nanomaterials have been frequently used to improve electrochemical biosensors for sensitively detecting foodborne pathogens due to their high conductivity, surface-to-volume ratio, and electrocatalytic activity. In this review, we survey the characteristics of biorecognition elements and nanomaterials in constructing electrochemical biosensors applicable for detecting foodborne pathogens during the past five years. As well as the challenges and opportunities of electrochemical biosensors in the application of foodborne pathogen detection are discussed.
Collapse
Affiliation(s)
- Avinash V Police Patil
- Department of Bio-Industrial Mechatronics Engineering, National Chung Hsing University, Taichung City 402, Taiwan R.O.C
| | - Ping-Feng Yang
- Department of Bio-Industrial Mechatronics Engineering, National Chung Hsing University, Taichung City 402, Taiwan R.O.C
| | - Chiou-Ying Yang
- Institute of Molecular Biology, National Chung Hsing University, Taichung 402, Taiwan R.O.C
| | - M S Gaur
- Department of Physics, Hindustan College of Science and Technology, Farah, Mathura, 281122 U.P., India
| | | |
Collapse
|
4
|
Park SH, You Y. Gold Nanoparticle-Based Colorimetric Biosensing for Foodborne Pathogen Detection. Foods 2023; 13:95. [PMID: 38201122 PMCID: PMC10778349 DOI: 10.3390/foods13010095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 12/13/2023] [Accepted: 12/23/2023] [Indexed: 01/12/2024] Open
Abstract
Ensuring safe high-quality food is an ongoing priority, yet consumers face heightened risk from foodborne pathogens due to extended supply chains and climate change in the food industry. Nanomaterial-based assays are popular and have recently been developed to ensure food safety and high quality. This review discusses strategies for utilizing gold nanoparticles in colorimetric biosensors. The visible-signal biosensor proves to be a potent sensing technique for directly measuring targets related to foodborne pathogens in the field of food analysis. Among visible-signal biosensors, the localized surface plasmon resonance (LSPR) biosensor has garnered increasing attention and experienced rapid development in recent years. This review succinctly introduces the origin of LSPR theory, providing detailed insights into its fundamental principles. Additionally, this review delves into the application of nanotechnology for the implementation of the LSPR biosensor, exploring methods for utilizing gold nanoparticles and elucidating the factors that influence the generation of visible signals. Several emerging technologies aimed at simple and rapid immunoassays for onsite applications have been introduced in the food industry. In the foreseeable future, field-friendly colorimetric biosensors could be adopted in food monitoring systems. The onsite and real-time detection of possible contaminants and biological substances in food and water is essential to ensure human health and safety.
Collapse
Affiliation(s)
- Sang-Hyun Park
- Department of Food Science and Technology, Kongju National University, Yesan 32439, Chungnam, Republic of Korea
| | - Youngsang You
- Department of Food Engineering, Dankook University, Cheonan 31116, Chungnam, Republic of Korea
| |
Collapse
|
5
|
Zaki FR, Monroy GL, Shi J, Sudhir K, Boppart SA. Texture-based speciation of otitis media-related bacterial biofilms from optical coherence tomography images using supervised classification. RESEARCH SQUARE 2023:rs.3.rs-3466690. [PMID: 37961282 PMCID: PMC10635317 DOI: 10.21203/rs.3.rs-3466690/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2023]
Abstract
Otitis media (OM) is primarily a bacterial middle-ear infection prevalent among children worldwide. In recurrent and/or chronic OM cases, antibiotic-resistant bacterial biofilms can develop in the middle ear. A biofilm related to OM typically contains one or multiple bacterial strains, the most common include Haemophilus influenzae, Streptococcus pneumoniae, Moraxella catarrhalis, Pseudomonas aeruginosa, and Staphylococcus aureus. Optical coherence tomography (OCT) has been used clinically to visualize the presence of bacterial biofilms in the middle ear. This study used OCT to compare microstructural image texture features from primary bacterial biofilms in vitro and in vivo. The proposed method applied supervised machine-learning-based frameworks (SVM, random forest (RF), and XGBoost) to classify and speciate multiclass bacterial biofilms from the texture features extracted from OCT B-Scan images obtained from in vitro cultures and from clinically-obtained in vivo images from human subjects. Our findings show that optimized SVM-RBF and XGBoost classifiers can help distinguish bacterial biofilms by incorporating clinical knowledge into classification decisions. Furthermore, both classifiers achieved more than 95% of AUC (area under receiver operating curve), detecting each biofilm class. These results demonstrate the potential for differentiating OM-causing bacterial biofilms through texture analysis of OCT images and a machine-learning framework, which could provide additional clinically relevant data during real-time in vivo characterization of ear infections.
Collapse
Affiliation(s)
- Farzana R Zaki
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
| | - Guillermo L Monroy
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
| | - Jindou Shi
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
| | - Kavya Sudhir
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
| | - Stephen A Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- Carle Illinois College of Medicine, University of Illinois Urbana-Champaign, Urbana, Illinois, USA
- NIH/NIBIB P41 Center for Label-free Imaging and Multiscale Biophotonics (CLIMB), University of Illinois Urbana-Champaign, Urbana, Illinois, USA
| |
Collapse
|
6
|
Yang B, Wang Y, Yan X, Fen Q, Chi Y. Primer Exchange Reaction (PER)-Based Construction of Scaffold for Low-Speed Centrifugation-Based Isolation and Quantitative Analysis of P. aeruginosa and its application in analyzing uterine secretions with intrauterine adhesion. Appl Biochem Biotechnol 2023:10.1007/s12010-023-04742-0. [PMID: 37819459 DOI: 10.1007/s12010-023-04742-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/15/2023] [Indexed: 10/13/2023]
Abstract
Efficient isolation and sensitive quantification of Pseudomonas aeruginosa (P. aeruginosa) are crucial for identifying intrauterine infections and preventing the occurrence of intrauterine adhesion (IUA). However, traditional approaches, such as culture-based approach, are time-consuming. Herein, we constructed a detection scaffold by using primer exchange reaction (PER) that integrated the low-speed centrifugation-based isolation and sensitive quantification of target pathogenic bacteria. The established approach possesses several advantages, including (i) the approach is capable of simultaneous isolation and sensitive quantification of target bacteria; (ii) low-speed centrifugation or even manual equipment could be used to isolate target bacteria; and (iii) a low limit of detection was obtained as 54 cfu/mL. Based on this, the approach is a promising approach in analyzing P. aeruginosa from uterine secretions with IUA.
Collapse
Affiliation(s)
- Boping Yang
- Department of General Gynecology, Women and Children's Hospital of Chongqing Medical University, Chongqing Health Center for Women and Children, Chongqing, 400037, People's Republic of China
| | - Ying Wang
- Department of General Gynecology, Women and Children's Hospital of Chongqing Medical University, Chongqing Health Center for Women and Children, Chongqing, 400037, People's Republic of China
| | - Xiaohuan Yan
- Department of General Gynecology, Women and Children's Hospital of Chongqing Medical University, Chongqing Health Center for Women and Children, Chongqing, 400037, People's Republic of China
| | - Qian Fen
- Hospital-Acquired Infection Control Department, Women and Children's Hospital of Chongqing Medical University, Chongqing Health Center for Women and Children, No. 120 Longshan Street, Yubei District, Chongqing, 400037, People's Republic of China.
| | - Yugang Chi
- Department of General Gynecology, Women and Children's Hospital of Chongqing Medical University, Chongqing Health Center for Women and Children, Chongqing, 400037, People's Republic of China.
| |
Collapse
|
7
|
Hu J, Liang L, He M, Lu Y. Sensitive and Direct Analysis of Pseudomonas aeruginosa through Self-Primer-Assisted Chain Extension and CRISPR-Cas12a-Based Color Reaction. ACS OMEGA 2023; 8:34852-34858. [PMID: 37779973 PMCID: PMC10536833 DOI: 10.1021/acsomega.3c04180] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 08/31/2023] [Indexed: 10/03/2023]
Abstract
Pseudomonas aeruginosa (P. aeruginosa) is a common opportunistic Gram-negative pathogen that may cause infections to immunocompromised patients. However, sensitive and reliable analysis of P. aeruginosa remains a huge challenge. In this method, target recognition assists the formation of a self-primer and initiates single-stranded chain production. The produced single-stranded DNA chain is identified by CRISPR-Cas12a, and consequently, the trans-cleavage activity of the Cas12a enzyme is activated to parallelly digest Ag+ aptamer sequences that are chelated with silver ions (Ag+). The released Ag+ reacted with 3,3',5,5'-tetramethylbenzidine (TMB) for coloring. Compared with the traditional color developing strategies, which mainly rely on the DNA hybridization, the color developing strategy in this approach exhibits a higher efficiency due to the robust trans-cleavage activity of the Cas12a enzyme. Consequently, the method shows a low limit of detection of a wide detection of 5 orders of magnitudes and a low limit of detection of 21 cfu/mL, holding a promising prospect in early diagnosis of infections. Herein, we develop a sensitive and reliable method for direct and colorimetric detection of P. aeruginosa by integrating self-primer-assisted chain production and CRISPR-Cas12a-based color reaction and believe that the established approach will facilitate the development of bacteria-analyzing sensors.
Collapse
Affiliation(s)
- Jiangchun Hu
- Science
and Technology Innovation Center, Guangyuan
Central Hospital, Guangyuan
City 628000, Sichuan
Province, China
| | - Ling Liang
- Science
and Technology Innovation Center, Guangyuan
Central Hospital, Guangyuan
City 628000, Sichuan
Province, China
| | - Mingfang He
- Science
and Technology Innovation Center, Guangyuan
Central Hospital, Guangyuan
City 628000, Sichuan
Province, China
| | - Yongping Lu
- Science
and Technology Innovation Center, Guangyuan
Central Hospital, Guangyuan
City 628000, Sichuan
Province, China
| |
Collapse
|
8
|
Mito D, Eda H, Okihara SI, Kurita M, Hatayama N, Yoshino Y, Watanabe Y, Ishii K. Optimizing Excitation Light for Accurate Rapid Bacterial Species Identification with Autofluorescence. J Fluoresc 2023:10.1007/s10895-023-03383-0. [PMID: 37597134 DOI: 10.1007/s10895-023-03383-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Accepted: 08/06/2023] [Indexed: 08/21/2023]
Abstract
Rapid identification of bacterial species in patient samples is essential for the treatment of infectious diseases and the economics of health care. In this study, we investigated an algorithm to improve the accuracy of bacterial species identification with fluorescence spectroscopy based on autofluorescence from bacteria, and excitation wavelengths suitable for identification. The diagnostic accuracy of each algorithm for ten bacterial species was verified in a machine learning classifier algorithm. The three machine learning algorithms with the highest diagnostic accuracy, extra tree (ET), logistic regression (LR), and multilayer perceptron (MLP), were used to determine the number and wavelength of excitation wavelengths suitable for the diagnosis of bacterial species. The key excitation wavelengths for the diagnosis of bacterial species were 280 nm, 300 nm, 380 nm, and 480 nm, with 280 nm being the most important. The median diagnostic accuracy was equivalent to that of 200 excitation wavelengths when two excitation wavelengths were used for ET and LR, and three excitation wavelengths for MLP. These results demonstrate that there is an optimum wavelength range of excitation wavelengths required for spectroscopic measurement of bacterial autofluorescence for bacterial species identification, and that measurement of only a few wavelengths in this range is sufficient to achieve sufficient accuracy for diagnosis of bacterial species.
Collapse
Affiliation(s)
- Daisuke Mito
- The Graduate School for the Creation of New Photonics Industries, Shizuoka, 431-1202, Japan.
- Trauma and Reconstruction Center, Teikyo University Hospital, Tokyo, Japan.
| | - Hideo Eda
- The Graduate School for the Creation of New Photonics Industries, Shizuoka, 431-1202, Japan
| | - Shin-Ichiro Okihara
- The Graduate School for the Creation of New Photonics Industries, Shizuoka, 431-1202, Japan
| | - Masakazu Kurita
- Department of Plastic and Reconstructive Surgery, the University of Tokyo Hospital, Tokyo, Japan
| | - Nami Hatayama
- School of Medicine, Department of Microbiology and Immunology, Teikyo University, Tokyo, Japan
| | - Yusuke Yoshino
- School of Medicine, Department of Microbiology and Immunology, Teikyo University, Tokyo, Japan
| | - Yoshinobu Watanabe
- Trauma and Reconstruction Center, Teikyo University Hospital, Tokyo, Japan
| | - Katsuhiro Ishii
- The Graduate School for the Creation of New Photonics Industries, Shizuoka, 431-1202, Japan
| |
Collapse
|
9
|
Zeininger L. Responsive Janus droplets as modular sensory layers for the optical detection of bacteria. Anal Bioanal Chem 2023:10.1007/s00216-023-04838-w. [PMID: 37450000 PMCID: PMC10404245 DOI: 10.1007/s00216-023-04838-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 06/28/2023] [Accepted: 06/30/2023] [Indexed: 07/18/2023]
Abstract
The field of biosensor development is fueled by innovations in new functional transduction materials and technologies. Material innovations promise to extend current sensor hardware limitations, reduce analysis costs, and ensure broad application of sensor methods. Optical sensors are particularly attractive because they enable sensitive and noninvasive analyte detection in near real-time. Optical transducers convert physical, chemical, or biological events into detectable changes in fluorescence, refractive index, or spectroscopic shifts. Thus, in addition to sophisticated biochemical selector designs, smart transducers can improve signal transmission and amplification, thereby greatly facilitating the practical applicability of biosensors, which, to date, is often hampered by complications such as difficult replication of reproducible selector-analyte interactions within a uniform and consistent sensing area. In this context, stimuli-responsive and optically active Janus emulsions, which are dispersions of kinetically stabilized biphasic fluid droplets, have emerged as a novel triggerable material platform that provides as a versatile and cost-effective alternative for the generation of reproducible, highly sensitive, and modular optical sensing layers. The intrinsic and unprecedented chemical-morphological-optical coupling inside Janus droplets has facilitated optical signal transduction and amplification in various chemo- and biosensor paradigms, which include examples for the rapid and cost-effective detection of major foodborne pathogens. These initial demonstrations resulted in detection limits that rival the capabilities of current commercial platforms. This trend article aims to present a conceptual summary of these initial efforts and to provide a concise and comprehensive overview of the pivotal kinetic and thermodynamic principles that govern the ability of Janus droplets to sensitively and selectively respond to and interact with bacteria.
Collapse
Affiliation(s)
- Lukas Zeininger
- Department of Colloid Chemistry, Max Planck Institute of Colloids and Interfaces, Am Muehlenberg 1, 14476, Potsdam, Germany.
| |
Collapse
|
10
|
Mohan B, Kumari R, Singh G, Singh K, Pombeiro AJL, Yang X, Ren P. Covalent organic frameworks (COFs) and metal-organic frameworks (MOFs) as electrochemical sensors for the efficient detection of pharmaceutical residues. ENVIRONMENT INTERNATIONAL 2023; 175:107928. [PMID: 37094512 DOI: 10.1016/j.envint.2023.107928] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 03/21/2023] [Accepted: 04/09/2023] [Indexed: 05/03/2023]
Abstract
Pharmaceutical residues are the undecomposed remains from drugs used in the medical and food industries. Due to their potential adverse effects on human health and natural ecosystems, they are of increasing worldwide concern. The acute detection of pharmaceutical residues can give a rapid examination of their quantity and then prevent them from further contamination. Herein, this study summarizes and discusses the most recent porous covalent-organic frameworks (COFs) and metal-organic frameworks (MOFs) for the electrochemical detection of various pharmaceutical residues. The review first introduces a brief overview of drug toxicity and its effects on living organisms. Subsequently, different porous materials and drug detection techniques are discussed with materials' properties and applications. Then the development of COFs and MOFs has been addressed with their structural properties and sensing applications. Further, the stability, reusability, and sustainability of MOFs/COFs are reviewed and discussed. Besides, COFs and MOFs' detection limits, linear ranges, the role of functionalities, and immobilized nanoparticles are analyzed and discussed. Lastly, this review summarized and discussed the MOF@COF composite as sensors, the fabrication strategies to enhance detection potential, and the current challenges in this area.
Collapse
Affiliation(s)
- Brij Mohan
- School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China; Centro de Química Estrutural, Institute of Molecular Sciences, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
| | - Ritu Kumari
- Department of Chemistry, Kurukshetra University Kurukshetra -136119, India
| | - Gurjaspreet Singh
- Department of Chemistry and Centre of Advanced Studies Panjab University, Chandigarh-160014, India
| | - Kamal Singh
- Department of Physics, Chaudhary Bansi Lal University, Bhiwani, Haryana-127021, India
| | - Armando J L Pombeiro
- Centro de Química Estrutural, Institute of Molecular Sciences, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
| | - Xuemei Yang
- School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China.
| | - Peng Ren
- School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China.
| |
Collapse
|
11
|
Zhang X, Zhang J, Wen Y. An efficient DNAzyme-based DNA scaffold for label-free and sensitive bacterial pathogen detection. Anal Biochem 2023; 666:115076. [PMID: 36764566 DOI: 10.1016/j.ab.2023.115076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 01/24/2023] [Accepted: 02/04/2023] [Indexed: 02/11/2023]
Abstract
Even though it is very important, it is still rather difficult to detect minuscule levels of the bacterial pathogen in clinical practice, such as samples from dental implants. We construct here an efficient scaffold for label-free and sensitive Staphylococcus aureus (S. aureus) detection. The precise recognition of target bacteria by the detection scaffold leads to the self-assembly of Chain i and DNAzyme based cleavage of Chain iii. In detail, active DNAzyme conformation is formed based on the hybridization of Chain iii and Chain ii, and a nicking site is generated in Chain iii, making it possible to form a self-primer in Chain i. With the assistance of DNA polymerase, a single-strand DNA chain is added to the 3' terminal of Chain i, in which process the bacteria is released for the complex to bind with a next detection scaffold, forming a signal recycle. Following DNAzyme-based cleavage, the liberated sequences unroll MB and release G-rich sequences that can specifically bind with the fluorescent dye Thioflavin T (ThT), initiating ThT's fluorescence signal production. The approach demonstrates a wide detection range of 102 CFU/mL and 106 CFU/mL with a low limit of detection of 45 CFU/mL based on the developed detection scaffold, offering good prospects in the diagnosis of bacterial illnesses.
Collapse
Affiliation(s)
- Xue Zhang
- Dental Department, People's Hospital of Chong Qing Liang Jiang New Area, Chongqing, 401120, China
| | - Jiali Zhang
- Dental Department, People's Hospital of Chong Qing Liang Jiang New Area, Chongqing, 401120, China
| | - Yongbin Wen
- Dental Department, People's Hospital of Chong Qing Liang Jiang New Area, Chongqing, 401120, China.
| |
Collapse
|
12
|
Doh IJ, Zuniga DVS, Shin S, Pruitt RE, Rajwa B, Robinson JP, Bae E. Bacterial Colony Phenotyping with Hyperspectral Elastic Light Scattering Patterns. SENSORS (BASEL, SWITZERLAND) 2023; 23:3485. [PMID: 37050545 PMCID: PMC10098818 DOI: 10.3390/s23073485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 03/16/2023] [Accepted: 03/24/2023] [Indexed: 06/19/2023]
Abstract
The elastic light-scatter (ELS) technique, which detects and discriminates microbial organisms based on the light-scatter pattern of their colonies, has demonstrated excellent classification accuracy in pathogen screening tasks. The implementation of the multispectral approach has brought further advantages and motivated the design and validation of a hyperspectral elastic light-scatter phenotyping instrument (HESPI). The newly developed instrument consists of a supercontinuum (SC) laser and an acousto-optic tunable filter (AOTF). The use of these two components provided a broad spectrum of excitation light and a rapid selection of the wavelength of interest, which enables the collection of multiple spectral patterns for each colony instead of relying on single band analysis. The performance was validated by classifying microflora of green-leafed vegetables using the hyperspectral ELS patterns of the bacterial colonies. The accuracy ranged from 88.7% to 93.2% when the classification was performed with the scattering pattern created at a wavelength within the 473-709 nm region. When all of the hyperspectral ELS patterns were used, owing to the vastly increased size of the data, feature reduction and selection algorithms were utilized to enhance the robustness and ultimately lessen the complexity of the data collection. A new classification model with the feature reduction process improved the overall classification rate to 95.9%.
Collapse
Affiliation(s)
- Iyll-Joon Doh
- Applied Optics Laboratory, School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
| | | | - Sungho Shin
- Department of Basic Medical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN 47907, USA
| | - Robert E. Pruitt
- Department of Botany and Plant Pathology, Purdue University, West Lafayette, IN 47907, USA
| | - Bartek Rajwa
- Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907, USA
| | - J. Paul Robinson
- Department of Basic Medical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN 47907, USA
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - Euiwon Bae
- Applied Optics Laboratory, School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
| |
Collapse
|
13
|
Pistiki A, Ryabchykov O, Bocklitz TW, Rösch P, Popp J. Use of polymers as wavenumber calibration standards in deep-UVRR. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 287:122062. [PMID: 36351311 DOI: 10.1016/j.saa.2022.122062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 10/10/2022] [Accepted: 10/29/2022] [Indexed: 06/16/2023]
Abstract
Deep-UV resonance Raman spectroscopy (UVRR) allows the classification of bacterial species with high accuracy and is a promising tool to be developed for clinical application. For this attempt, the optimization of the wavenumber calibration is required to correct the overtime changes of the Raman setup. In the present study, different polymers were investigated as potential calibration agents. The ones with many sharp bands within the spectral range 400-1900 cm-1 were selected and used for wavenumber calibration of bacterial spectra. Classification models were built using a training cross-validation dataset that was then evaluated with an independent test dataset obtained after 4 months. Without calibration, the training cross-validation dataset provided an accuracy for differentiation above 99 % that dropped to 51.2 % after test evaluation. Applying the test evaluation with PET and Teflon calibration allowed correct assignment of all spectra of Gram-positive isolates. Calibration with PS and PEI leads to misclassifications that could be overcome with majority voting. Concerning the very closely related and similar in genome and cell biochemistry Enterobacteriaceae species, all spectra of the training cross-validation dataset were correctly classified but were misclassified in test evaluation. These results show the importance of selecting the most suitable calibration agent in the classification of bacterial species and help in the optimization of the deep-UVRR technique.
Collapse
Affiliation(s)
- Aikaterini Pistiki
- Leibniz Institute of Photonic Technology Jena, Albert-Einstein-Str. 9, 07745 Jena, Germany
| | - Oleg Ryabchykov
- Leibniz Institute of Photonic Technology Jena, Albert-Einstein-Str. 9, 07745 Jena, Germany; Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Lessingstraße 10, 07743 Jena, Germany
| | - Thomas W Bocklitz
- Leibniz Institute of Photonic Technology Jena, Albert-Einstein-Str. 9, 07745 Jena, Germany; Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Lessingstraße 10, 07743 Jena, Germany
| | - Petra Rösch
- InfectoGnostics Research Campus Jena, Philosophenweg 7, 07743 Jena, Germany; Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Lessingstraße 10, 07743 Jena, Germany.
| | - Jürgen Popp
- Leibniz Institute of Photonic Technology Jena, Albert-Einstein-Str. 9, 07745 Jena, Germany; InfectoGnostics Research Campus Jena, Philosophenweg 7, 07743 Jena, Germany; Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Lessingstraße 10, 07743 Jena, Germany; Jena Biophotonics and Imaging Laboratory, Albert-Einstein-Str. 9, 07745 Jena, Germany; Center for Sepsis Control and Care, Jena University Hospital, Am Klinikum 1, 07747 Jena, Germany
| |
Collapse
|
14
|
Dina NE, Tahir MA, Bajwa SZ, Amin I, Valev VK, Zhang L. SERS-based antibiotic susceptibility testing: Towards point-of-care clinical diagnosis. Biosens Bioelectron 2023; 219:114843. [PMID: 36327563 DOI: 10.1016/j.bios.2022.114843] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 08/09/2022] [Accepted: 10/19/2022] [Indexed: 11/06/2022]
Abstract
Emerging antibiotic resistant bacteria constitute one of the biggest threats to public health. Surface-enhanced Raman scattering (SERS) is highly promising for detecting such bacteria and for antibiotic susceptibility testing (AST). SERS is fast, non-destructive (can probe living cells) and it is technologically flexible (readily integrated with robotics and machine learning algorithms). However, in order to integrate into efficient point-of-care (PoC) devices and to effectively replace the current culture-based methods, it needs to overcome the challenges of reliability, cost and complexity. Recently, significant progress has been made with the emergence of both new questions and new promising directions of research and technological development. This article brings together insights from several representative SERS-based AST studies and approaches oriented towards clinical PoC biosensing. It aims to serve as a reference source that can guide progress towards PoC routines for identifying antibiotic resistant pathogens. In turn, such identification would help to trace the origin of sporadic infections, in order to prevent outbreaks and to design effective medical treatment and preventive procedures.
Collapse
Affiliation(s)
- Nicoleta Elena Dina
- Department of Molecular and Biomolecular Department, National Institute for Research and Development of Isotopic and Molecular Technologies, 400293, Cluj-Napoca, Romania.
| | - Muhammad Ali Tahir
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Department of Environmental Science & Engineering, Fudan University, Shanghai, 200433, People's Republic of China
| | - Sadia Z Bajwa
- National Institute for Biotechnology and Genetic Engineering (NIBGE), P.O. Box No. 577, Jhang Road, 38000, Faisalabad, Pakistan
| | - Imran Amin
- National Institute for Biotechnology and Genetic Engineering (NIBGE), P.O. Box No. 577, Jhang Road, 38000, Faisalabad, Pakistan
| | - Ventsislav K Valev
- Centre for Photonics and Photonic Materials, Department of Physics, University of Bath, Bath, BA2 7AY, United Kingdom; Centre for Therapeutic Innovation, University of Bath, Bath, United Kingdom; Centre for Nanoscience and Nanotechnology, University of Bath, Bath, United Kingdom.
| | - Liwu Zhang
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Department of Environmental Science & Engineering, Fudan University, Shanghai, 200433, People's Republic of China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, 200092, People's Republic of China.
| |
Collapse
|
15
|
Hussain M, Zou J, Zhang H, Zhang R, Chen Z, Tang Y. Recent Progress in Spectroscopic Methods for the Detection of Foodborne Pathogenic Bacteria. BIOSENSORS 2022; 12:bios12100869. [PMID: 36291007 PMCID: PMC9599795 DOI: 10.3390/bios12100869] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 10/07/2022] [Accepted: 10/09/2022] [Indexed: 05/06/2023]
Abstract
Detection of foodborne pathogens at an early stage is very important to control food quality and improve medical response. Rapid detection of foodborne pathogens with high sensitivity and specificity is becoming an urgent requirement in health safety, medical diagnostics, environmental safety, and controlling food quality. Despite the existing bacterial detection methods being reliable and widely used, these methods are time-consuming, expensive, and cumbersome. Therefore, researchers are trying to find new methods by integrating spectroscopy techniques with artificial intelligence and advanced materials. Within this progress report, advances in the detection of foodborne pathogens using spectroscopy techniques are discussed. This paper presents an overview of the progress and application of spectroscopy techniques for the detection of foodborne pathogens, particularly new trends in the past few years, including surface-enhanced Raman spectroscopy, surface plasmon resonance, fluorescence spectroscopy, multiangle laser light scattering, and imaging analysis. In addition, the applications of artificial intelligence, microfluidics, smartphone-based techniques, and advanced materials related to spectroscopy for the detection of bacterial pathogens are discussed. Finally, we conclude and discuss possible research prospects in aspects of spectroscopy techniques for the identification and classification of pathogens.
Collapse
Affiliation(s)
- Mubashir Hussain
- School of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, China
- Postdoctoral Innovation Practice, Shenzhen Polytechnic, Liuxian Avenue, Nanshan District, Shenzhen 518055, China
| | - Jun Zou
- School of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, China
- Correspondence: (Z.J.); (T.Y.)
| | - He Zhang
- School of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, China
| | - Ru Zhang
- School of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, China
| | - Zhu Chen
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou 412007, China
| | - Yongjun Tang
- Postdoctoral Innovation Practice, Shenzhen Polytechnic, Liuxian Avenue, Nanshan District, Shenzhen 518055, China
- Correspondence: (Z.J.); (T.Y.)
| |
Collapse
|
16
|
Svetličić E, Dončević L, Ozdanovac L, Janeš A, Tustonić T, Štajduhar A, Brkić AL, Čeprnja M, Cindrić M. Direct Identification of Urinary Tract Pathogens by MALDI-TOF/TOF Analysis and De Novo Peptide Sequencing. Molecules 2022; 27:molecules27175461. [PMID: 36080229 PMCID: PMC9457756 DOI: 10.3390/molecules27175461] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 08/19/2022] [Accepted: 08/19/2022] [Indexed: 11/16/2022] Open
Abstract
For mass spectrometry-based diagnostics of microorganisms, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is currently routinely used to identify urinary tract pathogens. However, it requires a lengthy culture step for accurate pathogen identification, and is limited by a relatively small number of available species in peptide spectral libraries (≤3329). Here, we propose a method for pathogen identification that overcomes the above limitations, and utilizes the MALDI-TOF/TOF MS instrument. Tandem mass spectra of the analyzed peptides were obtained by chemically activated fragmentation, which allowed mass spectrometry analysis in negative and positive ion modes. Peptide sequences were elucidated de novo, and aligned with the non-redundant National Center for Biotechnology Information Reference Sequence Database (NCBInr). For data analysis, we developed a custom program package that predicted peptide sequences from the negative and positive MS/MS spectra. The main advantage of this method over a conventional MALDI-TOF MS peptide analysis is identification in less than 24 h without a cultivation step. Compared to the limited identification with peptide spectra libraries, the NCBI database derived from genome sequencing currently contains 20,917 bacterial species, and is constantly expanding. This paper presents an accurate method that is used to identify pathogens grown on agar plates, and those isolated directly from urine samples, with high accuracy.
Collapse
Affiliation(s)
- Ema Svetličić
- Novo Nordisk Foundation Center for Biosustainability, Technical University of Denmark, 2800 Lyngby, Denmark
| | - Lucija Dončević
- Division of Molecular Medicine, Ruđer Bošković Institute, Bijenička 54, 10000 Zagreb, Croatia
| | - Luka Ozdanovac
- Division of Molecular Medicine, Ruđer Bošković Institute, Bijenička 54, 10000 Zagreb, Croatia
| | - Andrea Janeš
- Clinical Department of Laboratory Diagnostics, University Hospital Dubrava, Avenija Gojka Šuška 6, 10000 Zagreb, Croatia
| | | | - Andrija Štajduhar
- Division for Medical Statistics, Andrija Štampar Teaching Institute of Public Health, Mirogojska cesta 16, 10000 Zagreb, Croatia
| | | | - Marina Čeprnja
- Special Hospital Agram, Agram EEIG, Trnjanska cesta 108, 10000 Zagreb, Croatia
| | - Mario Cindrić
- Division of Molecular Medicine, Ruđer Bošković Institute, Bijenička 54, 10000 Zagreb, Croatia
- Correspondence: ; Tel.: +385-16384422
| |
Collapse
|
17
|
Monroy GL, Won J, Shi J, Hill MC, Porter RG, Novak MA, Hong W, Khampang P, Kerschner JE, Spillman DR, Boppart SA. Automated classification of otitis media with OCT: augmenting pediatric image datasets with gold-standard animal model data. BIOMEDICAL OPTICS EXPRESS 2022; 13:3601-3614. [PMID: 35781950 PMCID: PMC9208614 DOI: 10.1364/boe.453536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 03/28/2022] [Accepted: 05/12/2022] [Indexed: 06/15/2023]
Abstract
Otitis media (OM) is an extremely common disease that affects children worldwide. Optical coherence tomography (OCT) has emerged as a noninvasive diagnostic tool for OM, which can detect the presence and quantify the properties of middle ear fluid and biofilms. Here, the use of OCT data from the chinchilla, the gold-standard OM model for the human disease, is used to supplement a human image database to produce diagnostically relevant conclusions in a machine learning model. Statistical analysis shows the datatypes are compatible, with a blended-species model reaching ∼95% accuracy and F1 score, maintaining performance while additional human data is collected.
Collapse
Affiliation(s)
- Guillermo L. Monroy
- Beckman Institute for Advanced
Science and Technology, 405 N Mathews Ave, Urbana, IL
61801, USA
| | - Jungeun Won
- Beckman Institute for Advanced
Science and Technology, 405 N Mathews Ave, Urbana, IL
61801, USA
- Department of Bioengineering,
University of Illinois at Urbana-Champaign,
1406 W Green St, Urbana, IL 61801, USA
| | - Jindou Shi
- Beckman Institute for Advanced
Science and Technology, 405 N Mathews Ave, Urbana, IL
61801, USA
- Department of Electrical and Computer
Engineering, University of Illinois at
Urbana-Champaign, 306 N Wright St, Urbana, IL 61801,
USA
| | - Malcolm C. Hill
- Carle Foundation
Hospital, 611 W Park St., Urbana, IL 61801, USA
| | - Ryan G. Porter
- Carle Foundation
Hospital, 611 W Park St., Urbana, IL 61801, USA
- Carle Illinois College of Medicine,
University of Illinois at Urbana-Champaign,
506 S. Mathews Ave., Urbana, IL 61801, USA
| | - Michael A. Novak
- Carle Foundation
Hospital, 611 W Park St., Urbana, IL 61801, USA
- Carle Illinois College of Medicine,
University of Illinois at Urbana-Champaign,
506 S. Mathews Ave., Urbana, IL 61801, USA
| | - Wenzhou Hong
- Department of Otolaryngology and
Communication Sciences, Medical College of
Wisconsin, Milwaukee, WI 53226, USA
| | - Pawjai Khampang
- Department of Otolaryngology and
Communication Sciences, Medical College of
Wisconsin, Milwaukee, WI 53226, USA
| | - Joseph E. Kerschner
- Department of Otolaryngology and
Communication Sciences, Medical College of
Wisconsin, Milwaukee, WI 53226, USA
- Division of Otolaryngology and Pediatric
Otolaryngology, Medical College of
Wisconsin, Milwaukee, WI 53226, USA
| | - Darold R. Spillman
- Beckman Institute for Advanced
Science and Technology, 405 N Mathews Ave, Urbana, IL
61801, USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced
Science and Technology, 405 N Mathews Ave, Urbana, IL
61801, USA
- Department of Bioengineering,
University of Illinois at Urbana-Champaign,
1406 W Green St, Urbana, IL 61801, USA
- Department of Electrical and Computer
Engineering, University of Illinois at
Urbana-Champaign, 306 N Wright St, Urbana, IL 61801,
USA
- Carle Illinois College of Medicine,
University of Illinois at Urbana-Champaign,
506 S. Mathews Ave., Urbana, IL 61801, USA
| |
Collapse
|
18
|
Chen Q, Wen Y. Target recognition triggered CRISPR-Cas12a assisted allosteric scaffold for sensitively analyzing bacterial infection after dental implantation. Anal Biochem 2022; 647:114666. [DOI: 10.1016/j.ab.2022.114666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 03/10/2022] [Accepted: 03/14/2022] [Indexed: 11/01/2022]
|
19
|
Liang S, Ji L, Zhong Y, Wang T, Yang H, Li QL, Li X, Zhao S. Fluorescence immunoassay for the targeted determination of trace Listeria monocytogenes based on immunomagnetic separation and CdZnTe quantum dot indication. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1124-1133. [PMID: 35212322 DOI: 10.1039/d1ay02106k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Infections from invasive Listeria monocytogenes (L. monocytogenes) frequently occur in food and can cause high morbidity and death. Thus, the sensitive, specific, and rapid detection of L. monocytogenes is critical for ensuring food safety and public health. Herein, a fluorescence immunoassay for trace L. monocytogenes detection was designed based on guinea pig antibody-functionalized magnetic nanoparticles (Fe3O4 NPs/pAb1) and rabbit antibody-anchored CdZnTe quantum dots (CdZnTe QDs/pAb2). Because of the antibody-directed magnetic separation and long-wave fluorescent emission for CdZnTe QD indication, the constructed immunoassay strategy presented excellent anti-interference performance toward a biological matrix. The immunosensor exhibited a wide detection range of 1 to 109 CFU mL-1 for L. monocytogenes and a low limit of detection (LOD) of 1 CFU mL-1, achieving an exceptionally sensitive detection of trace L. monocytogenes. Meanwhile, the immunosensor showed good specificity and had a short time-consumption of 60 min to realize the accurate determination of trace Listeria monocytogenes in spiked tap water and pasteurized milk samples.
Collapse
Affiliation(s)
- Shan Liang
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Li Ji
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Yingying Zhong
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Tiantian Wang
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Huiyi Yang
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Qing-Lan Li
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Xiangguang Li
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| | - Suqing Zhao
- Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China.
| |
Collapse
|
20
|
Rapid Bacterial Detection in Urine Using Laser Scattering and Deep Learning Analysis. Microbiol Spectr 2022; 10:e0176921. [PMID: 35234514 PMCID: PMC8941854 DOI: 10.1128/spectrum.01769-21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Images of laser scattering patterns generated by bacteria in urine are promising resources for deep learning. However, floating bacteria in urine produce dynamic scattering patterns and require deep learning of spatial and temporal features. We hypothesized that bacteria with variable bacterial densities and different Gram staining reactions would generate different speckle images. After deep learning of speckle patterns generated by various densities of bacteria in artificial urine, we validated the model in an independent set of clinical urine samples in a tertiary hospital. Even at a low bacterial density cutoff (1,000 CFU/mL), the model achieved a predictive accuracy of 90.9% for positive urine culture. At a cutoff of 50,000 CFU/mL, it showed a better accuracy of 98.5%. The model achieved satisfactory accuracy at both cutoff levels for predicting the Gram staining reaction. Considering only 30 min of analysis, our method appears as a new screening tool for predicting the presence of bacteria before urine culture. IMPORTANCE This study performed deep learning of multiple laser scattering patterns by the bacteria in urine to predict positive urine culture. Conventional urine analyzers have limited performance in identifying bacteria in urine. This novel method showed a satisfactory accuracy taking only 30 min of analysis without conventional urine culture. It was also developed to predict the Gram staining reaction of the bacteria. It can be used as a standalone screening tool for urinary tract infection.
Collapse
|
21
|
Monroy GL, Fitzgerald ST, Locke A, Won J, Spillman DR, Ho A, Zaki FR, Choi H, Chaney EJ, Werkhaven JA, Mason KM, Mahadevan-Jansen A, Boppart SA. Multimodal Handheld Probe for Characterizing Otitis Media - Integrating Raman Spectroscopy and Optical Coherence Tomography. FRONTIERS IN PHOTONICS 2022; 3:929574. [PMID: 36479543 PMCID: PMC9720905 DOI: 10.3389/fphot.2022.929574] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Otitis media (OM) is a common disease of the middle ear, affecting 80% of children before the age of three. The otoscope, a simple illuminated magnifier, is the standard clinical diagnostic tool to observe the middle ear. However, it has limited contrast to detect signs of infection, such as clearly identifying and characterizing middle ear fluid or biofilms that accumulate within the middle ear. Likewise, invasive sampling of every subject is not clinically indicated nor practical. Thus, collecting accurate noninvasive diagnostic factors is vital for clinicians to deliver a precise diagnosis and effective treatment regimen. To address this need, a combined benchtop Raman spectroscopy (RS) and optical coherence tomography (OCT) system was developed. Together, RS-OCT can non-invasively interrogate the structural and biochemical signatures of the middle ear under normal and infected conditions.In this paper, in vivo RS scans from pediatric clinical human subjects presenting with OM were evaluated in parallel with RS-OCT data of physiologically relevant in vitro ear models. Component-level characterization of a healthy tympanic membrane and malleus bone, as well as OM-related middle ear fluid, identified the optimal position within the ear for RS-OCT data collection. To address the design challenges in developing a system specific to clinical use, a prototype non-contact multimodal handheld probe was built and successfully tested in vitro. Design criteria have been developed to successfully address imaging constraints imposed by physiological characteristics of the ear and optical safety limits. Here, we present the pathway for translation of RS-OCT for non-invasive detection of OM.
Collapse
Affiliation(s)
- Guillermo L. Monroy
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, United States
| | - Sean T. Fitzgerald
- Vanderbilt Biophotonics Center, Nashville, TN, United States
- Dept. Biomedical Engineering, Vanderbilt University, Nashville, TN, United States
| | - Andrea Locke
- Vanderbilt Biophotonics Center, Nashville, TN, United States
- Dept. Biomedical Engineering, Vanderbilt University, Nashville, TN, United States
| | - Jungeun Won
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, United States
- Dept. Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, United States
| | - Darold R. Spillman
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, United States
| | - Alexander Ho
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, United States
- Dept. Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, United States
| | - Farzana R. Zaki
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, United States
| | - Honggu Choi
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, United States
| | - Eric J. Chaney
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, United States
| | - Jay A. Werkhaven
- Dept. Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Kevin M. Mason
- Center for Microbial Pathogenesis, The Abigail Wexner Research Institute Nationwide Children’s Hospital, Columbus, OH, United States
| | - Anita Mahadevan-Jansen
- Vanderbilt Biophotonics Center, Nashville, TN, United States
- Dept. Biomedical Engineering, Vanderbilt University, Nashville, TN, United States
- Dept. Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, United States
- Correspondence: Anita Mahadevan-Jansen, , Stephen A. Boppart,
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, IL, United States
- Dept. Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, United States
- Dept. Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, United States
- Carle Illinois College of Medicine, University of Illinois Urbana-Champaign, Urbana, IL, United States
- Cancer Center at Illinois, University of Illinois Urbana-Champaign, Urbana, IL, United States
- Correspondence: Anita Mahadevan-Jansen, , Stephen A. Boppart,
| |
Collapse
|
22
|
Thomas RE, Thomas BC. Reducing Biofilm Infections in Burn Patients' Wounds and Biofilms on Surfaces in Hospitals, Medical Facilities and Medical Equipment to Improve Burn Care: A Systematic Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:13195. [PMID: 34948803 PMCID: PMC8702030 DOI: 10.3390/ijerph182413195] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/08/2021] [Accepted: 12/09/2021] [Indexed: 11/21/2022]
Abstract
Biofilms in burns are major problems: bacterial communities rapidly develop antibiotic resistance, and 60% of burn mortality is attributed to biofilms. Key pathogens are Pseudomonas aeruginosa, methicillin-resistant Staphylococcus aureus, and multidrug-resistant Acinetobacter baumanii. Purpose: identify current and novel interventions to reduce biofilms on patients' burns and hospital surfaces and equipment. Medline and Embase were searched without date or language limits, and 31 possible interventions were prioritised: phages, nano-silver, AgSD-NLs@Cur, Acticoat and Mepilex silver, acetic acid, graphene-metal combinations, CuCo2SO4 nanoparticles, Chlorhexidene acetate nanoemulsion, a hydrogel with moxifloxacin, carbomer, Chitosan and Boswellia, LED light therapy with nano-emodin or antimicrobial blue light + Carvacrol to release reactive oxygen species, mannosidase + trypsin, NCK-10 (a napthalene compound with a decyl chain), antimicrobial peptide PV3 (includes two snake venoms), and polypeptides P03 and PL2. Most interventions aimed to penetrate cell membranes and reported significant reductions in biofilms in cfu/mL or biofilm mass or antibiotic minimal inhibitory concentrations or bacterial expression of virulence or quorum sensing genes. Scanning electron microscopy identified important changes in bacterial surfaces. Patients with biofilms need isolating and treating before full admission to hospital. Cleaning and disinfecting needs to include identifying biofilms on keyboards, tablets, cell phones, medical equipment (especially endoscopes), sinks, drains, and kitchens.
Collapse
Affiliation(s)
- Roger E. Thomas
- Department of Family Medicine, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 4N1, Canada
| | | |
Collapse
|
23
|
Tahir MA, Dina NE, Cheng H, Valev VK, Zhang L. Surface-enhanced Raman spectroscopy for bioanalysis and diagnosis. NANOSCALE 2021; 13:11593-11634. [PMID: 34231627 DOI: 10.1039/d1nr00708d] [Citation(s) in RCA: 66] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
In recent years, bioanalytical surface-enhanced Raman spectroscopy (SERS) has blossomed into a fast-growing research area. Owing to its high sensitivity and outstanding multiplexing ability, SERS is an effective analytical technique that has excellent potential in bioanalysis and diagnosis, as demonstrated by its increasing applications in vivo. SERS allows the rapid detection of molecular species based on direct and indirect strategies. Because it benefits from the tunable surface properties of nanostructures, it finds a broad range of applications with clinical relevance, such as biological sensing, drug delivery and live cell imaging assays. Of particular interest are early-stage-cancer detection and the fast detection of pathogens. Here, we present a comprehensive survey of SERS-based assays, from basic considerations to bioanalytical applications. Our main focus is on SERS-based pathogen detection methods as point-of-care solutions for early bacterial infection detection and chronic disease diagnosis. Additionally, various promising in vivo applications of SERS are surveyed. Furthermore, we provide a brief outlook of recent endeavours and we discuss future prospects and limitations for SERS, as a reliable approach for rapid and sensitive bioanalysis and diagnosis.
Collapse
Affiliation(s)
- Muhammad Ali Tahir
- Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Department of Environmental Science & Engineering, Fudan University, Shanghai, 200433, Peoples' Republic of China.
| | | | | | | | | |
Collapse
|
24
|
García-Hernández J, Hernández M, Moreno Y. Combination of Direct Viable Count and Fluorescent In Situ Hybridization (DVC-FISH) as a Potential Method for Identifying Viable Vibrio parahaemolyticus in Oysters and Mussels. Foods 2021; 10:foods10071502. [PMID: 34209577 PMCID: PMC8303443 DOI: 10.3390/foods10071502] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 06/18/2021] [Accepted: 06/25/2021] [Indexed: 11/21/2022] Open
Abstract
Vibrio parahaemolyticus is a human food-borne pathogen with the ability to enter the food chain. It is able to acquire a viable, non-cultivable state (VBNC), which is not detected by traditional methods. The combination of the direct viable count method and a fluorescent in situ hybridization technique (DVC-FISH) makes it possible to detect microorganisms that can present VBNC forms in complex samples The optimization of the in vitro DVC-FISH technique for V. parahaemolyticus was carried out. The selected antibiotic was ciprofloxacin at a concentration of 0.75 μg/mL with an incubation time in DVC broth of 5 h. The DVC-FISH technique and the traditional plate culture were applied to detect and quantify the viable cells of the affected pathogen in artificially contaminated food matrices at different temperatures. The results obtained showed that low temperatures produced an important logarithmic decrease of V. parahaemolyticus, while at 22 °C, it proliferated rapidly. The DVC-FISH technique proved to be a useful tool for the detection and quantification of V. parahaemolyticus in the two seafood matrices of oysters and mussels. This is the first study in which this technique has been developed to detect viable cells for this microorganism.
Collapse
Affiliation(s)
- Jorge García-Hernández
- Advanced Center for Food Microbiology, Biotechnology Department, Universitat Politècnica de València, 46022 Valencia, Spain;
- Correspondence: ; Tel.: +34-658993099
| | - Manuel Hernández
- Advanced Center for Food Microbiology, Biotechnology Department, Universitat Politècnica de València, 46022 Valencia, Spain;
| | - Yolanda Moreno
- Research Institute of Water and Environmental Ingeneering (IIAMA), Universitat Politècnica de València, 46022 Valencia, Spain;
| |
Collapse
|
25
|
Doh IJ, Kim H, Sturgis J, Rajwa B, Robinson JP, Bae E. Optical multi-channel interrogation instrument for bacterial colony characterization. PLoS One 2021; 16:e0247721. [PMID: 33630969 PMCID: PMC7906345 DOI: 10.1371/journal.pone.0247721] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 02/11/2021] [Indexed: 11/18/2022] Open
Abstract
A single instrument that includes multiple optical channels was developed to simultaneously measure various optical and associated biophysical characteristics of a bacterial colony. The multi-channel device can provide five distinct optical features without the need to transfer the sample to multiple locations or instruments. The available measurement channels are bright-field light microscopy, 3-D colony-morphology map, 2-D spatial optical-density distribution, spectral forward-scattering pattern, and spectral optical density. The series of multiple morphological interrogations is beneficial in understanding the bio-optical features of a bacterial colony and the correlations among them, resulting in an enhanced power of phenotypic bacterial discrimination. To enable a one-shot interrogation, a confocal laser scanning module was built as an add-on to an upright microscope. Three different-wavelength diode lasers were used for the spectral analysis, and high-speed pin photodiodes and CMOS sensors were utilized as detectors to measure the spectral OD and light-scatter pattern. The proposed instrument and algorithms were evaluated with four bacterial genera, Escherichia coli, Listeria innocua, Salmonella Typhimurium, and Staphylococcus aureus; their resulting data provided a more complete picture of the optical characterization of bacterial colonies.
Collapse
Affiliation(s)
- Iyll-Joon Doh
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, United States of America
| | - Huisung Kim
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, United States of America
| | - Jennifer Sturgis
- Basic Medical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, United States of America
| | - Bartek Rajwa
- Bindley Bioscience Center, Purdue University, West Lafayette, Indiana, United States of America
| | - J. Paul Robinson
- Basic Medical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, United States of America
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, United States of America
| | - Euiwon Bae
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, United States of America
- * E-mail:
| |
Collapse
|
26
|
Abstract
<abstract>
<p>In diagnosing the urinary tract and related diseases, the problem of light scattering from human urine was examined on the basis of classical electromagnetic theory. Numerical calculations were made for the designed cylindrical model with the help of optical parameters in the literature obtained from the laboratory test results of urine samples. In the designed model, the changes of the scattered intensity of the light from the urine solution according to the size parameter of the particles and the angular distribution of the system (including forward, side and back scattering) in the equatorial plane were obtained, in both transverse electric (TE) and transverse magnetic (TM) of the polarization states of the light. It was observed that the molecular density changes caused by the materials in the urine sample changed primarily the optical parameters and indirectly the intensity distribution of the scattered light. Thus, with the contribution of standard data provided as a result of light scatter calculations from urine samples taken from people with normal and different diseases, it will be easier to diagnose diseases that will be encountered later.</p>
</abstract>
Collapse
|