DiBlasi RM, Engberg RJ, Poli J, Carlin KE, Kontoudios N, Longest PW, Kajimoto M. Aerosol Delivery Efficiency With High-Flow Nasal Cannula Therapy in Neonatal, Pediatric, and Adult Nasal Upper-Airway and Lung Models. Respir Care 2024; 69:1146-1160. [PMID: 38981652 PMCID: PMC11349594 DOI: 10.4187/respcare.11400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/11/2024]
Abstract
BACKGROUND High-flow nasal cannula (HFNC) systems employ different methods to provide aerosol to patients. This study compared delivery efficiency, particle size, and regional deposition of aerosolized bronchodilators during HFNC in neonatal, pediatric, and adult upper-airway and lung models between a proximal aerosol adapter and distal aerosol circuit chamber. METHODS A filter was connected to the upper airway to a spontaneously breathing lung model. Albuterol was nebulized using the aerosol adapter and circuit at different clinical flow settings. The aerosol mass deposited in the upper airway and lung was quantified. Particle size was measured with a laser diffractometer. Regional deposition was assessed with a gamma camera at each nebulizer location and patient model with minimum flow settings. RESULTS Inhaled lung doses ranged from 0.2-0.8% for neonates, 0.2-2.2% for the small child, and 0.5-5.2% for the adult models. Neonatal inhaled lung doses were not different between the aerosol circuit and adapter, but the aerosol circuit showed marginally greater lung doses in the pediatric and adult patient models. Impacted aerosols and condensation in the non-heated HFNC and aerosol delivery components contributed to the dispersion of coarse liquid droplets, high deposition (11-44%), and occlusion of the supine neonatal upper airway. In contrast, the upright pediatric and adult upper-airway models had minimal deposition (0.3-7.0%) and high fugitive losses (∼24%) from liquid droplets leaking out of the nose. The high impactive losses in the aerosol adapter (56%) were better contained than in the aerosol circuit, resulting in less cannula sputter (5% vs 22%), fewer fugitive losses (18% vs 24%), and smaller inhaled aerosols (5 µm vs 13 µm). CONCLUSIONS The inhaled lung dose was low (1-5%) during HFNC. Approaches that streamline aerosol delivery are needed to provide safe and effective therapy to patients receiving aerosolized medications with this HFNC system.
Collapse
Affiliation(s)
- Robert M DiBlasi
- Respiratory Therapy Department, Seattle Children's Hospital, Seattle, Washington; and Center for Respiratory Biology and Therapeutics, Seattle Children's Research Institute, Seattle, Washington
| | - Rebecca J Engberg
- Center for Respiratory Biology and Therapeutics, Seattle Children's Research Institute, Seattle, Washington; and Pediatric Intensive Care Unit, Seattle Children's Hospital, Seattle, Washington
| | - Jonathan Poli
- Center for Respiratory Biology and Therapeutics, Seattle Children's Research Institute, Seattle, Washington
| | - Kristen E Carlin
- Center for Clinical and Translational Research, Seattle Children's Research Institute, Seattle, Washington
| | - Niko Kontoudios
- Respiratory Therapy Department, Seattle Children's Hospital, Seattle, Washington; and Center for Respiratory Biology and Therapeutics, Seattle Children's Research Institute, Seattle, Washington
| | - P Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia
| | - Masaki Kajimoto
- Center for Respiratory Biology and Therapeutics, Seattle Children's Research Institute, Seattle, Washington
| |
Collapse
|
2
|
Seifelnasr A, Zare F, Si XA, Xi J. Optimized gravity-driven intranasal drop administration delivers significant doses to the ostiomeatal complex and maxillary sinus. Drug Deliv Transl Res 2024; 14:1839-1859. [PMID: 38044376 DOI: 10.1007/s13346-023-01488-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/23/2023] [Indexed: 12/05/2023]
Abstract
Chronic and allergic rhinosinusitis impacts approximately 12% of the global population. Challenges in rhinosinusitis treatment include paranasal sinus inaccessibility and variability in delivery efficiency among individuals. This study addresses these challenges of drug delivery by developing a high-efficiency, low-variability protocol for nasal drop delivery to the ostiomeatal complex (OMC) and maxillary sinus. Patient-specific nasal casts were dissected to reveal the configurations of conchae and meatus, providing insights into anatomical features amendable for sinus delivery. Fluorescent dye-enhanced videos visualized the dynamic liquid translocation in transparent nasal casts, allowing real-time assessment and quick adjustment to delivery parameters. Dosimetry to the OMC and maxillary sinus were quantified as drop count and mass using a precision scale. Key delivery factors, including the device type, formulation, and head-chin orientation, were systematically investigated in a cohort of ten nasal casts. Results show that both the squeeze bottle and soft-mist nasal pump yielded notably low doses to the OMC with high variability, and no dose from these two devices was detected within the maxillary sinuses. In contrast, the proposed approach, which included a curved nozzle surpassing the nasal valve and leveraged gravity-driven liquid translocation along the lateral nasal wall, delivered significant doses to the OMC and maxillary sinus. Iterative experimentations identified the optimal head tilt to be 40° and chin tilt to be° from the lateral recumbent position. Statistical analyses established the drop count required for effective OMC/sinus delivery. The proposed delivery protocol holds the potential to enhance chronic rhinosinusitis treatment outcomes with low variability. The dual role of nasal anatomy in posing challenges and offering opportunities highlights the need for future investigations using diverse formulations in a larger cohort of nasal models.
Collapse
Affiliation(s)
- Amr Seifelnasr
- Department of Biomedical Engineering, University of Massachusetts, 1 University Ave., Falmouth Hall 302I, Lowell, MA, 01854, USA
| | - Farhad Zare
- Department of Mechanical Engineering, Shiraz University, Shiraz, Iran
| | - Xiuhua April Si
- Department of Mechanical Engineering, California Baptist University, Riverside, CA, USA
| | - Jinxiang Xi
- Department of Biomedical Engineering, University of Massachusetts, 1 University Ave., Falmouth Hall 302I, Lowell, MA, 01854, USA.
| |
Collapse
|
3
|
Seifelnasr A, Si X, Xi J. Effects of Nozzle Retraction Elimination on Spray Distribution in Middle-Posterior Turbinate Regions: A Comparative Study. Pharmaceutics 2024; 16:683. [PMID: 38794345 PMCID: PMC11124954 DOI: 10.3390/pharmaceutics16050683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Revised: 05/08/2024] [Accepted: 05/17/2024] [Indexed: 05/26/2024] Open
Abstract
The standard multi-dose nasal spray pump features an integrated actuator and nozzle, which inevitably causes a retraction of the nozzle tip during application. The retraction stroke is around 5.5 mm and drastically reduces the nozzle's insertion depth, which further affects the initial nasal spray deposition and subsequent translocation, potentially increasing drug wastes and dosimetry variability. To address this issue, we designed a new spray pump that separated the nozzle from the actuator and connected them with a flexible tube, thereby eliminating nozzle retraction during application. The objective of this study is to test the new device's performance in comparison to the conventional nasal pump in terms of spray generation, plume development, and dosimetry distribution. For both devices, the spray droplet size distribution was measured using a laser diffraction particle analyzer. Plume development was recorded with a high-definition camera. Nasal dosimetry was characterized in two transparent nasal cavity casts (normal and decongested) under two breathing conditions (breath-holding and constant inhalation). The nasal formulation was a 0.25% w/v methyl cellulose aqueous solution with a fluorescent dye. For each test case, the temporospatial spray translocation in the nasal cavity was recorded, and the final delivered doses were quantified in five nasal regions. The results indicate minor differences in droplet size distribution between the two devices. The nasal plume from the new device presents a narrower plume angle. The head orientation, the depth at which the nozzle is inserted into the nostril, and the administration angle play crucial roles in determining the initial deposition of nasal sprays as well as the subsequent translocation of the liquid film/droplets. Quantitative measurements of deposition distributions in the nasal models were augmented with visualization recordings to evaluate the delivery enhancements introduced by the new device. With an extension tube, the modified device produced a lower spray output and delivered lower doses in the front, middle, and back turbinate than the conventional nasal pump. However, sprays from the new device were observed to penetrate deeper into the nasal passages, predominantly through the middle-upper meatus. This resulted in consistently enhanced dosing in the middle-upper turbinate regions while at the cost of higher drug loss to the pharynx.
Collapse
Affiliation(s)
- Amr Seifelnasr
- Department of Biomedical Engineering, University of Massachusetts, Lowell, MA 01854, USA;
| | - Xiuhua Si
- Department of Aerospace, Industrial and Mechanical Engineering, California Baptist University, Riverside, CA 92504, USA;
| | - Jinxiang Xi
- Department of Biomedical Engineering, University of Massachusetts, Lowell, MA 01854, USA;
| |
Collapse
|
4
|
Seifelnasr A, Talaat M, Si XA, Xi J. Delivery of Agarose-aided Sprays to the Posterior Nose for Mucosa Immunization and Short-term Protection against Infectious Respiratory Diseases. Curr Pharm Biotechnol 2024; 25:787-798. [PMID: 37533243 DOI: 10.2174/1389201024666230801142913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 06/13/2023] [Accepted: 06/20/2023] [Indexed: 08/04/2023]
Abstract
AIM The study aimed to deliver sprays to the posterior nose for mucosa immunization or short-term protection. BACKGROUND Respiratory infectious diseases often enter the human body through the nose. Sars- Cov-2 virus preferentially binds to the ACE2-rich tissue cells in the Nasopharynx (NP). Delivering medications to the nose, especially to the NP region, provides either a short-term protective/ therapeutic layer or long-term mucosa immunization. Hydrogel-aided medications can assist film formation, prolong film life, and control drug release. However, conventional nasal sprays have failed to dispense mediations to the posterior nose, with most sprays lost in the nasal valve and front turbinate. OBJECTIVE The objective of the study was to develop a practical delivery system targeting the posterior nose and quantify the dosimetry distribution of agarose-saline solutions in the nasal cavity. METHODS The solution viscosities with various hydrogel concentrations (0.1-1%) were measured at different temperatures. Dripping tests on a vertical plate were conducted to understand the hydrogel concentration effects on the liquid film stability and mobility. Transparent nasal airway models were used to visualize the nasal spray deposition and liquid film translocation. RESULTS Spray dosimetry with different hydrogel concentrations and inhalation flow rates was quantified on a total and regional basis. The solution viscosity increased with decreasing temperature, particularly in the range of 60-40oC. The liquid viscosity, nasal spray atomization, and liquid film mobility were highly sensitive to the hydrogel concentration. Liquid film translocations significantly enhanced delivered doses to the caudal turbinate and nasopharynx when the sprays were administered at 60oC under an inhalation flow rate of 11 L/min with hydrogel concentrations no more than 0.5%. On the other hand, sprays with 1% hydrogel or administered at 40oC would significantly compromise the delivered doses to the posterior nose. CONCLUSION Delivering sufficient doses of hydrogel sprays to the posterior nose is feasible by leveraging the post-administration liquid film translocation.
Collapse
Affiliation(s)
- Amr Seifelnasr
- Department of Biomedical Engineering, University of Massachusetts Lowell, Lowell, MA, USA
| | - Mohamed Talaat
- Department of Biomedical Engineering, University of Massachusetts Lowell, Lowell, MA, USA
| | - Xiuhua April Si
- Department of Aerospace, Industrial, and Mechanical Engineering, California Baptist University, Riverside, CA, USA
| | - Jinxiang Xi
- Department of Biomedical Engineering, University of Massachusetts Lowell, Lowell, MA, USA
| |
Collapse
|
5
|
Doub WH, Suman JM, Copley M, Goodey AP, Hosseini S, Mitchell JP. Laboratory Performance Testing of Aqueous Nasal Inhalation Products for Droplet/Particle Size Distribution: an Assessment from the International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS). AAPS PharmSciTech 2023; 24:208. [PMID: 37817001 DOI: 10.1208/s12249-023-02665-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 09/21/2023] [Indexed: 10/12/2023] Open
Abstract
Although nasal inhalation products are becoming more and more important for the delivery of medicines, characterization of these products for quality control and assessment of bioequivalence is complicated. Most of the problems encountered are associated with the assessment of aerodynamic droplet/particle size distribution (APSD). The droplets produced by the various nasal devices are large, and for suspension products, individual droplets may contain multiple drug particles or none at all. Assessment of suspension products is further complicated by the presence of solid excipient particles. These complications make it imperative that the limitations of the instruments used for characterization as well as the underlying assumptions that govern the interpretation of data produced by these instruments are understood. In this paper, we describe various methodologies used to assess APSD for nasal inhalation products and discuss proper use, limitations, and new methodologies on the horizon.
Collapse
Affiliation(s)
- William H Doub
- OINDP In Vitro Analysis, 1430 Neffwold Ln, Kirkwood, Missouri, 63122, USA.
| | | | | | | | | | - Jolyon P Mitchell
- Jolyon Mitchell Inhaler Consulting Services Inc, 1154 St. Anthony Road, London, Ontario, N6H2R1, Canada
| |
Collapse
|
6
|
Xi J, Si XA, Malvè M. Nasal anatomy and sniffing in respiration and olfaction of wild and domestic animals. Front Vet Sci 2023; 10:1172140. [PMID: 37520001 PMCID: PMC10375297 DOI: 10.3389/fvets.2023.1172140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 06/29/2023] [Indexed: 08/01/2023] Open
Abstract
Animals have been widely utilized as surrogate models for humans in exposure testing, infectious disease experiments, and immunology studies. However, respiratory diseases affect both humans and animals. These disorders can spontaneously affect wild and domestic animals, impacting their quality and quantity of life. The origin of such responses can primarily be traced back to the pathogens deposited in the respiratory tract. There is a lack of understanding of the transport and deposition of respirable particulate matter (bio-aerosols or viruses) in either wild or domestic animals. Moreover, local dosimetry is more relevant than the total or regionally averaged doses in assessing exposure risks or therapeutic outcomes. An accurate prediction of the total and local dosimetry is the crucial first step to quantifying the dose-response relationship, which in turn necessitates detailed knowledge of animals' respiratory tract and flow/aerosol dynamics within it. In this review, we examined the nasal anatomy and physiology (i.e., structure-function relationship) of different animals, including the dog, rat, rabbit, deer, rhombus monkey, cat, and other domestic and wild animals. Special attention was paid to the similarities and differences in the vestibular, respiratory, and olfactory regions among different species. The ventilation airflow and behaviors of inhaled aerosols were described as pertinent to the animals' mechanisms for ventilation modulation and olfaction enhancement. In particular, sniffing, a breathing maneuver that animals often practice enhancing olfaction, was examined in detail in different animals. Animal models used in COVID-19 research were discussed. The advances and challenges of using numerical modeling in place of animal studies were discussed. The application of this technique in animals is relevant for bidirectional improvements in animal and human health.
Collapse
Affiliation(s)
- Jinxiang Xi
- Department of Biomedical Engineering, University of Massachusetts, Lowell, MA, United States
| | - Xiuhua April Si
- Department of Mechanical Engineering, California Baptist University, Riverside, CA, United States
| | - Mauro Malvè
- Department of Engineering, Public University of Navarre, Pamplona, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Madrid, Spain
| |
Collapse
|
7
|
Seifelnasr A, Si XA, Xi J. Visualization and Estimation of Nasal Spray Delivery to Olfactory Mucosa in an Image-Based Transparent Nasal Model. Pharmaceutics 2023; 15:1657. [PMID: 37376105 DOI: 10.3390/pharmaceutics15061657] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 05/25/2023] [Accepted: 06/04/2023] [Indexed: 06/29/2023] Open
Abstract
Background: Nose-to-brain (N2B) drug delivery offers unique advantages over intravenous methods; however, the delivery efficiency to the olfactory region using conventional nasal devices and protocols is low. This study proposes a new strategy to effectively deliver high doses to the olfactory region while minimizing dose variability and drug losses in other regions of the nasal cavity. Materials and Methods: The effects of delivery variables on the dosimetry of nasal sprays were systematically evaluated in a 3D-printed anatomical model that was generated from a magnetic resonance image of the nasal airway. The nasal model comprised four parts for regional dose quantification. A transparent nasal cast and fluorescent imaging were used for visualization, enabling detailed examination of the transient liquid film translocation, real-time feedback on input effect, and prompt adjustment to delivery variables, which included the head position, nozzle angle, applied dose, inhalation flow, and solution viscosity. Results: The results showed that the conventional vertex-to-floor head position was not optimal for olfactory delivery. Instead, a head position tilting 45-60° backward from the supine position gave a higher olfactory deposition and lower variability. A two-dose application (250 mg) was necessary to mobilize the liquid film that often accumulated in the front nose following the first dose administration. The presence of an inhalation flow reduced the olfactory deposition and redistributed the sprays to the middle meatus. The recommended olfactory delivery variables include a head position ranging 45-60°, a nozzle angle ranging 5-10°, two doses, and no inhalation flow. With these variables, an olfactory deposition fraction of 22.7 ± 3.7% was achieved in this study, with insignificant discrepancies in olfactory delivery between the right and left nasal passages. Conclusions: It is feasible to deliver clinically significant doses of nasal sprays to the olfactory region by leveraging an optimized combination of delivery variables.
Collapse
Affiliation(s)
- Amr Seifelnasr
- Department of Biomedical Engineering, University of Massachusetts, Lowell, MA 01854, USA
| | - Xiuhua April Si
- Department of Mechanical Engineering, California Baptist University, Riverside, CA 92504, USA
| | - Jinxiang Xi
- Department of Biomedical Engineering, University of Massachusetts, Lowell, MA 01854, USA
| |
Collapse
|