1
|
Jin G, Ravichandran V, Shim MS, Kim JE. Incorporating an artificially synthesized fluoride complex into urethane-acrylate-based 3D printing resin: Effects on mechanical properties, cytotoxicity, antimicrobial actions, and its long-term fluoride-releasing properties. J Dent 2024; 150:105363. [PMID: 39349093 DOI: 10.1016/j.jdent.2024.105363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Revised: 09/10/2024] [Accepted: 09/19/2024] [Indexed: 10/02/2024] Open
Abstract
OBJECTIVES To synthesize a 3D printing resin with antibacterial and long-term fluoride-releasing properties. METHODS (4,4-Bis-4-[2‑hydroxy-3-(2-methacryloyloxy)propoxy]-phenyl-pentanol-amine)-N,N-diacetic acid zirconium (IV) fluoride complex was synthesized from 4,4-bis-(4-hydroxyphenyl)-pentanoic acid and monitored using proton nuclear magnetic resonance spectroscopy. The synthesized complex was incorporated into a urethane-acrylate-based (UA) resin at 5 wt% and 10 wt% (5F-UA and 10F-UA groups, respectively). The UA resin without the synthesized complex was considered as the control group. All groups were 3D printed using a DLP printer, followed by 10 min of washing and 20 min of curing. Surface characteristics were observed using scanning electron microscopy. The mechanical properties were assessed by measuring its flexural strength and Vickers hardness. The antibacterial property was investigated with direct and indirect contact tests and a WST-8 metabolic activity assay. The suspension was fully mixed and diluted for counting the number of colony-forming units. The cell viability test was performed using a cell proliferation assay. The amount of fluoride released was measured daily for 28 days using ion chromatography. One-way analysis of variance was performed for statistical analyses using SPSS software. RESULTS The amount of fluoride released increased with the concentration of fluoride complex in the resin. The fluoride ions were constantly released at a low concentration from the 3D printed specimens (5F-UA: around 0.13 ppm daily; 10F-UA: around 0.22 ppm daily). The antibacterial efficacy was acceptable in both the 5F-UA and 10F-UA groups, and higher in the latter. No cytotoxicity of the resin was detected. The mechanical properties were significantly influenced by the addition of the fluoride-releasing complex. CONCLUSIONS The present 3D printing UA resin incorporating a fluoride complex effectively inhibited the growth of S. mutans and demonstrated the ability to slowly release fluoride over an extended period of time. CLINICAL SIGNIFICANCE This study provided informative composition of a fluoride-releasing UA-based 3D printing resin, ideal for dental applications such as crowns, bridges, removable partial dentures, and orthodontic appliances, which can benefit from sustained fluoride release and antimicrobial properties. Further modifications to the resin composition can be easily achieved to enhance the resin qualities.
Collapse
Affiliation(s)
- Gan Jin
- Department of Prosthodontics, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| | - Vasanthan Ravichandran
- Division of Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
| | - Min Suk Shim
- Division of Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
| | - Jong-Eun Kim
- Department of Prosthodontics, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea.
| |
Collapse
|
2
|
Hassanpour M, Narongdej P, Alterman N, Moghtadernejad S, Barjasteh E. Effects of Post-Processing Parameters on 3D-Printed Dental Appliances: A Review. Polymers (Basel) 2024; 16:2795. [PMID: 39408505 PMCID: PMC11479229 DOI: 10.3390/polym16192795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2024] [Revised: 09/25/2024] [Accepted: 09/29/2024] [Indexed: 10/20/2024] Open
Abstract
In recent years, additive manufacturing (AM) has been recognized as a transformative force in the dental industry, with the ability to address escalating demand, expedite production timelines, and reduce labor-intensive processes. Despite the proliferation of three-dimensional printing technologies in dentistry, the absence of well-established post-processing protocols has posed formidable challenges. This comprehensive review paper underscores the critical importance of precision in post-processing techniques for ensuring the acquisition of vital properties, encompassing mechanical strength, biocompatibility, dimensional accuracy, durability, stability, and aesthetic refinement in 3D-printed dental devices. Given that digital light processing (DLP) is the predominant 3D printing technology in dentistry, the main post-processing techniques and effects discussed in this review primarily apply to DLP printing. The four sequential stages of post-processing support removal, washing, secondary polymerization, and surface treatments are systematically navigated, with each phase requiring meticulous evaluation and parameter determination to attain optimal outcomes. From the careful selection of support removal tools to the consideration of solvent choice, washing methodology, and post-curing parameters, this review provides a comprehensive guide for practitioners and researchers. Additionally, the customization of post-processing approaches to suit the distinct characteristics of different resin materials is highlighted. A comprehensive understanding of post-processing techniques is offered, setting the stage for informed decision-making and guiding future research endeavors in the realm of dental additive manufacturing.
Collapse
Affiliation(s)
- Mana Hassanpour
- Department of Chemical Engineering, California State University Long Beach, Long Beach, CA 90840, USA; (M.H.); (S.M.)
| | - Poom Narongdej
- Department of Mechanical and Aerospace Engineering, California State University Long Beach, Long Beach, CA 90840, USA; (P.N.); (N.A.)
| | - Nicolas Alterman
- Department of Mechanical and Aerospace Engineering, California State University Long Beach, Long Beach, CA 90840, USA; (P.N.); (N.A.)
| | - Sara Moghtadernejad
- Department of Chemical Engineering, California State University Long Beach, Long Beach, CA 90840, USA; (M.H.); (S.M.)
| | - Ehsan Barjasteh
- Department of Chemical Engineering, California State University Long Beach, Long Beach, CA 90840, USA; (M.H.); (S.M.)
- Department of Mechanical and Aerospace Engineering, California State University Long Beach, Long Beach, CA 90840, USA; (P.N.); (N.A.)
| |
Collapse
|
3
|
Santi MR, Khodor N, Sekula M, Donatelli D, De Souza GM. Effect of cleaning solution on surface properties of 3D-printed denture materials. J Prosthodont 2024. [PMID: 39233451 DOI: 10.1111/jopr.13936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 08/17/2024] [Indexed: 09/06/2024] Open
Abstract
PURPOSE To evaluate the effect of cleaning solutions on surface properties of 3D-printed resins. MATERIALS AND METHODS Seven different resin materials for denture base and teeth were used in the form of 280 half-disks. Samples were randomly assigned to two cleaning groups (FD, FreshDent; PO, Polydent), with daily 2- or 3-min immersion followed by water storage, repeated for 30 days. Samples were then cleaned in an ultrasonic bath with water and analyzed for surface roughness (Keyence, VHX-7000N) and hardness (Shimadzu, HMV-2 series). The pH of cleaning solutions was analyzed over 5-min and the surface morphology of specimens was analyzed via scanning electron microscopy (SEM). Statistical analysis used two-way ANOVA (α = 0.05). RESULTS Surface roughness of base materials was significantly affected (p < 0.001), whereas roughness of teeth materials was not. As for hardness, there was a significant interaction between materials and cleaning solution for both, base (p < 0.001) and teeth (p < 0.001). For teeth materials, PO significantly increased Denture's (Dentca) hardness and decreased that of Rodin's (Pac Dent), while PO significantly increased Rodin's Base (Pac Dent) hardness. The hardness of Flexcera Ultra (Envision Tec), Glidewell (Glidewell), Lucitone (Dentsply Sirona), and NextDent (NextDent) teeth and base materials were not affected by the cleaning solution. Overall, the pH of FD averaged 7.3 and PO averaged 6.6. All the SEM images indicated surface irregularities after immersion in either FD or PO. CONCLUSIONS One-month of storage and cyclic cleaning of 3D- printed resins did not affect surface roughness but had a significant impact on hardness. The cleaning solutions' effect was not homogeneous among materials.
Collapse
Affiliation(s)
- Marina Rodrigues Santi
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Nadima Khodor
- Department of Rehabilitative and Reconstructive Dentistry, University of Louisville, School of Dentistry, Louisville, Kentucky, USA
| | - Michael Sekula
- Department of Bioinformatics and Biostatistics, University of Louisville, School of Dentistry, University of Louisville, Louisville, Kentucky, USA
| | - David Donatelli
- Department of Rehabilitative and Reconstructive Dentistry, University of Louisville, School of Dentistry, Louisville, Kentucky, USA
| | - Grace Mendonça De Souza
- Department of Comprehensive Dentistry, University of Louisville, School of Dentistry, Louisville, Kentucky, USA
| |
Collapse
|
4
|
Odent J, Baleine N, Torcasio SM, Gautier S, Coulembier O, Raquez JM. 3D-Printed Phenylboronic Acid-Bearing Hydrogels for Glucose-Triggered Drug Release. Polymers (Basel) 2024; 16:2502. [PMID: 39274135 PMCID: PMC11398034 DOI: 10.3390/polym16172502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2024] [Revised: 08/19/2024] [Accepted: 08/30/2024] [Indexed: 09/16/2024] Open
Abstract
Diabetes is a major health concern that the next-generation of on-demand insulin releasing implants may overcome via personalized therapy. Therein, 3D-printed phenylboronic acid-containing implants with on-demand glucose-triggered drug release abilities are produced using high resolution stereolithography technology. To that end, the methacrylation of phenylboronic acid is targeted following a two-step reaction. The resulting photocurable phenylboronic acid derivative is accordingly incorporated within bioinert polyhydroxyethyl methacrylate-based hydrogels at varying loadings. The end result is a sub-centimeter scaled 3D-printed bioinert implant that can be remotely activated with 1,2-diols and 1,3-diols such as glucose for on-demand drug administration such as insulin. As a proof of concept, varying glucose concentration from hypoglycemic to hyperglycemic levels readily allow the release of pinacol, i.e., a 1,2-diol-containing model molecule, at respectively low and high rates. In addition, the results demonstrated that adjusting the geometry and size of the 3D-printed part is a simple and suitable method for tailoring the release behavior and dosage.
Collapse
Affiliation(s)
- Jérémy Odent
- Laboratory of Polymeric and Composite Materials (LPCM), Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 20, 7000 Mons, Belgium
| | - Nicolas Baleine
- Laboratory of Polymeric and Composite Materials (LPCM), Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 20, 7000 Mons, Belgium
| | - Serena Maria Torcasio
- Laboratory of Polymeric and Composite Materials (LPCM), Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 20, 7000 Mons, Belgium
| | - Sarah Gautier
- Laboratory of Polymeric and Composite Materials (LPCM), Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 20, 7000 Mons, Belgium
| | - Olivier Coulembier
- Laboratory of Polymeric and Composite Materials (LPCM), Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 20, 7000 Mons, Belgium
| | - Jean-Marie Raquez
- Laboratory of Polymeric and Composite Materials (LPCM), Center of Innovation and Research in Materials and Polymers (CIRMAP), University of Mons (UMONS), Place du Parc 20, 7000 Mons, Belgium
| |
Collapse
|
5
|
Gad MM, Hamad HMA, Almohsin FM, Fouda SM, Akhtar S, Khan SQ, Rahoma A, Al-Qarni FD, Baba NZ, Al-Harbi FA. Repair strength of 3D-printed denture base resins: Effect of surface treatment and repair material type. J Prosthodont 2024. [PMID: 39188160 DOI: 10.1111/jopr.13925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 07/01/2024] [Accepted: 07/28/2024] [Indexed: 08/28/2024] Open
Abstract
PURPOSE The aim of the study was to investigate the effect of surface treatment and repair materials on the flexural strength of repaired 3D-printed denture base resins after thermal aging. MATERIALS AND METHODS Bar-shape specimens (64 × 10 × 3.3 mm) were designed as intact (control) specimens while repair specimens were printed in sections with 2.5 mm space for repair material. Printing was performed with either ASIGA or NextDent denture base material. In each material, one group received no surface treatment, while other repair groups were subjected to one of three surface treatments: (1) monomer application, (2) aluminium oxide particles-abrasion, or (3) both methods (aluminum oxide particles-abrasion and monomer application). Pairs were fixed in a customized mold then repaired with either autopolymerizing acrylic resin or flowable composite (n = 9). Repaired specimens were incubated for 48 h at 37°C in distilled water and then subjected to thermal cycling (5000 cycles). A 3-point bending test was used to evaluate the flexural strength using a universal testing machine, and mode of failure determined followed by fractured surface analysis using scanning electron microscope. Data were analyzed using ANOVA and post hoc Tukey test (α = 0.05). RESULTS Both resin materials showed a significant decrease in the flexural strength of repaired specimens when compared to control ones (p < 0.001). Groups with no surface treatment had significantly lower flexural strength than those with surface treatment (p < 0.001). Groups treated with monomer application, and with aluminum oxide particles abrasion plus monomer application had similar flexural strength values (p > 0.05), which were higher than those treated with aluminum oxide particles abrasion alone (p < 0.001). Specimens repaired with composite resin showed higher flexural strength than those repaired with auto-polymerized resin (p < 0.05) however, specimens treated with aluminum oxide particles abrasion alone had similar values for both repair materials (p = 0.95). Adhesive failure was dominant in all repaired groups with auto-polymerized while cohesive and mixed were dominant with composite repair groups. CONCLUSION Surface treatment improved the repair strength of 3D-printed denture base resins. Using composite resin for repair shows better strength with dominant cohesive and mixed failure suggesting that surface treatment and composite repair are suitable procedures for 3D-printed denture base repair.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Hawra M Al Hamad
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fatimah M Almohsin
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Soban Q Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmed Rahoma
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal D Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Nadim Z Baba
- Advanced Specialty Education Program in Implant Dentistry, Loma Linda University, School of Dentistry, California, USA
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
6
|
Bassenheim D, Rist K, Moszner N, Catel Y, Liska R, Knaack P. Color-Stable Formulations for 3D-Photoprintable Dental Materials. Polymers (Basel) 2024; 16:2323. [PMID: 39204542 PMCID: PMC11359577 DOI: 10.3390/polym16162323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Revised: 08/03/2024] [Accepted: 08/13/2024] [Indexed: 09/04/2024] Open
Abstract
Color stability is crucial for dental materials to ensure they perfectly match a patient's tooth color. This is particularly challenging in photoresist-based additive manufacturing. Although some studies have addressed this issue, the exact causes of discoloration and ways to minimize it remain unclear. In this study, the intrinsic causes of discoloration in materials intended for 3D printing are investigated by examining thin-film samples (1200 µm) of various compositions, which are stored under different conditions. The samples are evaluated by measuring the UV-Vis absorption spectra at regular intervals to monitor changes. The findings reveal that both the composition of the formulations and the storage conditions significantly influence the discoloration behavior. Furthermore, methods have been developed to reduce or completely prevent discoloration. The use of photoinitiators with sterically demanding benzoyl moieties, as well as the addition of stabilizers, effectively decreases the intensity of emerging discoloration. Furthermore, incorporating the oxidizing agent cumene hydroperoxide (CHP) results in materials that maintain color stability.
Collapse
Affiliation(s)
- David Bassenheim
- Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9/163 MC, A-1060 Vienna, Austria
| | - Kai Rist
- Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein (Y.C.)
| | - Norbert Moszner
- Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein (Y.C.)
| | - Yohann Catel
- Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein (Y.C.)
| | - Robert Liska
- Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9/163 MC, A-1060 Vienna, Austria
| | - Patrick Knaack
- Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9/163 MC, A-1060 Vienna, Austria
| |
Collapse
|
7
|
Souza LFB, Pires TS, Kist PP, Valandro LF, Moraes RR, Özcan M, Pereira GKR. 3D printed, subtractive, and conventional acrylic resins: Evaluation of monotonic versus fatigue behavior and surface characteristics. J Mech Behav Biomed Mater 2024; 155:106556. [PMID: 38676972 DOI: 10.1016/j.jmbbm.2024.106556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 04/01/2024] [Accepted: 04/17/2024] [Indexed: 04/29/2024]
Abstract
This study assessed the mechanical properties and surface characteristics of dental prosthetic acrylic resin fabricated by 3D printing, comparing it with subtractive, pressing, and molding techniques. Bar-shaped specimens (N= 90; 65 × 10 × 3.3 mm; ISO:207951) were prepared and assigned into six groups: PRINT (3D printing vis stereolithography with PriZma 3D Bio Denture, Makertech Labs); SUB (subtractive manufacturing with Vipiblock Trilux, Vipi); PRESS Base (pressing using muffle with Thermo Vipi Wave, Vipi for base); PRESS Tooth (pressing with Onda-cryl, Clássico for tooth); MOLD Base (molding using addition silicone with Vipi Flash, Vipi for base); and MOLD Tooth (molding with Dencor, Clássico for tooth). Monotonic flexural strength (FS) and elastic modulus (E) were measured using a three-point bending approach (n= 5) on a universal testing machine at a crosshead speed of 5 mm/min. Fatigue testing (n= 10) followed similar geometry and settings, with a frequency of 2 Hz, initial stress level at 20 MPa, and stress increments of 5 MPa every 2,500 cycles. Surface roughness (n= 10) was assessed through profilometry, and fractographic and topographic analyses were conducted. Statistical analyses included One-Way ANOVA for monotonic FS, roughness, and E, along with Kaplan-Meier with Mantel-Cox post-hoc and Weibull analysis for fatigue strength. PRINT showed lower monotonic FS than the SUB and PRESS Tooth but comparable fatigue strength to these groups and superior to PRESS Base and MOLD (Base and Tooth) groups. All groups had similar Weibull moduli. Surface roughness of the PRINT group was comparable to most techniques but higher than the PRESS Tooth group. Fractographic analysis revealed fractures originating from surface defects under tensile stress, with SEM showing scratch patterns in all groups except PRINT, which had a more uniform surface. Despite its lower monotonic strength, 3D printed resin demonstrated comparable fatigue strength to subtractive and pressing methods and similar surface roughness to most methods, indicating its potential as a viable option for dental prosthesis.
Collapse
Affiliation(s)
- Luiza Freitas Brum Souza
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Center for Development of Advanced Materials, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Telma Souza Pires
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Center for Development of Advanced Materials, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Priscila Pauli Kist
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Center for Development of Advanced Materials, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Center for Development of Advanced Materials, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Rafael R Moraes
- Post-Graduate Program in Dentistry, Faculty of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.
| | - Mutlu Özcan
- Clinic for Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, 8032, Zurich, Switzerland.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Center for Development of Advanced Materials, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
8
|
Alamo L, Cassiano FB, Bordini EAF, Stuani VT, Pacheco LE, Gallinari MDO, Souza Costa CA, Mondelli RFL, Soares DG. An organotypic model of oral mucosa cells for the biological assessment of 3D printed resins for interim restorations. J Prosthet Dent 2024; 132:251-259. [PMID: 35864023 DOI: 10.1016/j.prosdent.2022.04.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 04/18/2022] [Accepted: 04/18/2022] [Indexed: 10/17/2022]
Abstract
STATEMENT OF PROBLEM Three-dimensionally (3D) printed resins have become popular as a new class of materials for making interim restorations. However, little is known about how the fabrication parameters can influence biological compatibility with oral tissues. PURPOSE The purpose of this in vitro study was to evaluate the effect of the postpolymerization time on the cytotoxicity of resins for printing interim restorations by using a 3D organotypic model of the oral mucosa. MATERIAL AND METHODS Cylindrical specimens were prepared with conventional acrylic resin (AR), computer-aided design and computer-aided manufacture (CAD-CAM) resin (CC), composite resin (CR), and 2 resins for 3D printing (3DP) marketed as being biocompatible. The 3DPs were submitted to postpolymerization in an ultraviolet (UV) light chamber for 1, 10, or 20 minutes (90 W, 405 nm). Standard specimens of the materials were incubated for 1, 3, and 7 days in close contact with an organotypic model of keratinocytes (NOK-Si) in coculture with gingival fibroblasts (HGF) in a 3D collagen matrix, or directly with 3D HGF cultures. Then, the viability (Live/Dead n=2) and metabolism (Alamar Blue n=6) of the cells were assessed. Spectral scanning of the culture medium was performed to detect released components (n=6) and assessed statistically with ANOVA and the Tukey post hoc test (α=.05). RESULTS Severe reduction of metabolism (>70%) and viability of keratinocytes occurred for 3DP resin postpolymerized for 1 minute in all periods of analysis in a time-dependent manner. The decrease in cell metabolism and viability was moderate for the 3D culture of HGFs in both experimental models, correlated with the intense presence of resin components in the culture medium. The resins postpolymerized for 10 and 20 minutes promoted a mild-moderate cytotoxic effect in the period of 1 day, similar to AR. However, recovery of cell viability occurred at the 7-day incubation period. The 3DP resins submitted to postpolymerization for 20 minutes showed a pattern similar to that of CR and CC at the end of the experiment. CONCLUSIONS The cytotoxic potential of the tested 3DP resins on oral mucosa cells was influenced by postprinting processing, which seemed to have been related with the quantity of residual components leached.
Collapse
Affiliation(s)
- Larissa Alamo
- MS student, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), São Paulo, Brazil
| | - Fernanda Balestrero Cassiano
- PhD student, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), São Paulo, Brazil
| | - Ester Alves Ferreira Bordini
- Postdoctoral Researcher, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), São Paulo, Brazil
| | - Vitor Toledo Stuani
- Postdoctoral Researcher, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), São Paulo, Brazil
| | - Leandro Edgar Pacheco
- PhD student, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), São Paulo, Brazil
| | - Marjorie de Oliveira Gallinari
- Postdoctoral Researcher, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), São Paulo, Brazil
| | - Carlos Alberto Souza Costa
- Full Professor, Department of Physiology and Pathology, School of Dentistry, São Paulo State University (UNESP), Araraquara, Brazil
| | - Rafael Francisco Lia Mondelli
- Full Professor, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), São Paulo, Brazil
| | - Diana Gabriela Soares
- Assistant Professor, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), São Paulo, Brazil.
| |
Collapse
|
9
|
Chuchulska B, Dimitrova M, Vlahova A, Hristov I, Tomova Z, Kazakova R. Comparative Analysis of the Mechanical Properties and Biocompatibility between CAD/CAM and Conventional Polymers Applied in Prosthetic Dentistry. Polymers (Basel) 2024; 16:877. [PMID: 38611135 PMCID: PMC11013798 DOI: 10.3390/polym16070877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 03/14/2024] [Accepted: 03/19/2024] [Indexed: 04/14/2024] Open
Abstract
Modern media often portray CAD/CAM technology as widely utilized in the fabrication of dental prosthetics. This study presents a comparative analysis of the mechanical properties and biocompatibility of CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) polymers and conventional polymers commonly utilized in prosthetic dentistry. With the increasing adoption of CAD/CAM technology in dental laboratories and practices, understanding the differences in material properties is crucial for informed decision-making in prosthodontic treatment planning. Through a narrative review of the literature and empirical data, this study evaluates the mechanical strength, durability, esthetics, and biocompatibility of CAD/CAM polymers in comparison to traditional polymers. Furthermore, it examines the implications of these findings on the clinical outcomes and long-term success of prosthetic restorations. The results provide valuable insights into the advantages and limitations of CAD/CAM polymers, informing clinicians and researchers about their suitability for various dental prosthetic applications. This study underscores the considerable advantages of CAD/CAM polymers over conventional ones in terms of mechanical properties, biocompatibility, and esthetics for prosthetic dentistry. CAD/CAM technology offers improved mechanical strength and durability, potentially enhancing the long-term performance of dental prosthetics, while the biocompatibility of these polymers makes them suitable for a broad patient demographic, reducing the risk of adverse reactions. The practical implications of these findings for dental technicians and dentists are significant, as understanding these material differences enables tailored treatment planning to meet individual patient needs and preferences. Integration of CAD/CAM technology into dental practices can lead to more predictable outcomes and heightened patient satisfaction with prosthetic restorations.
Collapse
Affiliation(s)
- Bozhana Chuchulska
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Mariya Dimitrova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Angelina Vlahova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Ilian Hristov
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Zlatina Tomova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Rada Kazakova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| |
Collapse
|
10
|
Chander NG, Mahajan A. Comparison of cytotoxicity between 3D printable resins and heat-cure PMMA. J Oral Biol Craniofac Res 2024; 14:107-110. [PMID: 38304040 PMCID: PMC10831252 DOI: 10.1016/j.jobcr.2024.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 12/06/2023] [Accepted: 01/10/2024] [Indexed: 02/03/2024] Open
Abstract
Aim The aim of this study was to evaluate and compare the cytotoxicity of polyurethane and polyoxymethylene printable resins with conventional heat cure polymethyl methacrylate denture base resins. Methods The study followed ISO-10993-5 guidelines. It comprised of three groups. Fifteen cuboidal samples measuring 10x10 × 10mm dimension were prepared for each group. The polymethylmethacrylate samples were fabricated using conventional denture processing techniques, while the polyoxymethylene samples were printed using fused deposition modeling and the polyurethane samples using stereolithography technique. Post fabrication the samples were evaluated for cytotoxicity using the MTT assay with the VERO cell line. The percentage of cell viability was calculated to determine the cytotoxic effects. Results Statistical analysis revealed a significant difference in the cell viability of the experimental groups (p ≤ 0.0001). The polyoxymethylene group showed the highest % cell viability (62.78 %), followed by the polymethylmethacrylate group (52.43 %), and the least was observed in the polyurethane-based resin group (46.47 %). The findings indicate polyoxymethylene group displayed least cytotoxicity, followed by polymethylmethacrylate, and polyurethane-based resin. Conclusion Polyoxymethylene resin exhibited the minimum cytotoxic properties among the tested materials, followed by polymethylmethacrylate and polyurethane resin.
Collapse
Affiliation(s)
- N. Gopi Chander
- Department of Prosthodontics, SRM Dental College, Ramapuram, Chennai, 89, India
| | - Aashmika Mahajan
- Department of Prosthodontics, SRM Dental College, Ramapuram, Chennai, 89, India
| |
Collapse
|
11
|
Prakash J, Shenoy M, Alhasmi A, Al Saleh AA, C SG, Shivakumar S. Biocompatibility of 3D-Printed Dental Resins: A Systematic Review. Cureus 2024; 16:e51721. [PMID: 38318586 PMCID: PMC10839546 DOI: 10.7759/cureus.51721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 01/05/2024] [Indexed: 02/07/2024] Open
Abstract
BACKGROUND The biocompatibility of 3D-printed dental resins has become a critical concern in modern dentistry due to the increasing utilization of additive manufacturing (AM) techniques in dental applications. These resins serve as essential materials for fabricating dental prostheses, orthodontic devices, and various dental components. As the clinical adoption of 3D printing in dentistry grows, it is imperative to comprehensively assess the biocompatibility of these materials to ensure patient safety and dental treatment efficacy. This systematic review aimed to evaluate the existing body of literature on the biocompatibility of 3D-printed dental resins, thereby providing valuable insights into the potential biological risks associated with their use. METHODS The search strategy to identify relevant papers was implemented across PubMed/MEDLINE, Scopus, Web of Science, Embase, Cochrane Library, CINAHL, and Google Scholar to identify relevant studies. Study selection was not limited to any particular timeframe of publishing. The revised CONSORT criteria were used to ascertain the authenticity and dependability of the review's outcomes. Comprehensive screening and eligibility assessment processes were conducted to select studies meeting predefined criteria. Biocompatibility-related parameters, including toxicity, mechanical properties, cell viability, and other relevant outcomes, were analyzed across selected studies using a standardized variable extraction protocol. RESULTS A total of 9 studies were included in the systematic review. The findings encompassed various aspects of biocompatibility assessment, including material composition, mechanical properties, cell viability, and cytotoxicity. Some studies revealed significant improvements in flexural strength and cell viability with specific resin formulations, demonstrating their potential for enhanced clinical utility. Conversely, certain resins exhibited cytotoxicity, while others displayed promising biocompatibility profiles. CONCLUSION As per the assessed findings, material composition, post-processing techniques, and manufacturing methods emerged as critical factors influencing biocompatibility outcomes. While some resins exhibited favorable biocompatibility profiles, others raised concerns due to cytotoxicity. These findings emphasize the need for careful consideration when selecting and implementing 3D-printed dental resins, with a focus on materials engineering and comprehensive biocompatibility testing. Further research is warranted to elucidate the long-term biocompatibility and clinical implications of these materials.
Collapse
Affiliation(s)
- Jayant Prakash
- Department of Prosthodontics, Dental Institute, Rajendra Institute of Medical Sciences, Ranchi, IND
| | - Mahesh Shenoy
- Department of Oral and Maxillofacial Surgery and Diagnostic Sciences, College of Medicine and Dentistry, Riyadh Elm University, Riyadh, SAU
| | - Abdulmajeed Alhasmi
- Department of Periodontics, King Salman Hospital, Ministry of Health, Riyadh, SAU
| | | | - Shivakumar G C
- Department of Oral Medicine and Radiology, People's College of Dental Sciences and Research Centre, Bhopal, IND
| | - Sahana Shivakumar
- Department of Public Health Dentistry, People's College of Dental Sciences and Research Centre, Bhopal, IND
| |
Collapse
|
12
|
Dimitrova M, Vlahova A, Kalachev Y, Zlatev S, Kazakova R, Capodiferro S. Recent Advances in 3D Printing of Polymers for Application in Prosthodontics. Polymers (Basel) 2023; 15:4525. [PMID: 38231950 PMCID: PMC10708542 DOI: 10.3390/polym15234525] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 11/15/2023] [Accepted: 11/22/2023] [Indexed: 01/19/2024] Open
Abstract
Contemporary mass media frequently depict 3D printing as a technology with widespread utilization in the creation of dental prosthetics. This paper endeavors to provide an evidence-based assessment of the current scope of 3D printing's integration within dental laboratories and practices. Its primary objective is to offer a systematic evaluation of the existing applications of 3D-printing technology within the realm of dental prosthetic restorations. Furthermore, this article delves into potential prospects, while also critically examining the sustained relevance of conventional dental laboratory services and manufacturing procedures. The central focus of this article is to expound upon the extent to which 3D printing is presently harnessed for crafting dental prosthetic appliances. By presenting verifiable data and factual insights, this article aspires to elucidate the actual implementation of 3D printing in prosthetic dentistry and its seamless integration into dental practices. The aim of this narrative review is twofold: firstly, to provide an informed and unbiased evaluation of the role that 3D printing currently plays within dental laboratories and practices; and secondly, to instigate contemplation on the transformative potential of this technology, both in terms of its contemporary impact and its future implications, while maintaining a balanced consideration of traditional dental approaches.
Collapse
Affiliation(s)
- Mariya Dimitrova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
| | - Angelina Vlahova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Yavor Kalachev
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
| | - Stefan Zlatev
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Rada Kazakova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Saverio Capodiferro
- Department of Interdisciplinary Medicine, Aldo Moro, University of Bari, 70100 Bari, Italy;
| |
Collapse
|
13
|
Fei J, Rong Y, Zhu L, Li H, Zhang X, Lu Y, An J, Bao Q, Huang X. Progress in Photocurable 3D Printing of Photosensitive Polyurethane: A Review. Macromol Rapid Commun 2023; 44:e2300211. [PMID: 37294875 DOI: 10.1002/marc.202300211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/15/2023] [Indexed: 06/11/2023]
Abstract
In recent years, as a class of advanced additive manufacturing (AM) technology, photocurable 3D printing has gained increasing attention. Based on its outstanding printing efficiency and molding accuracy, it is employed in various fields, such as industrial manufacturing, biomedical, soft robotics, electronic sensors. Photocurable 3D printing is a molding technology based on the principle of area-selective curing of photopolymerization reaction. At present, the main printing material suitable for this technology is the photosensitive resin, a composite mixture consisting of a photosensitive prepolymer, reactive monomer, photoinitiator, and other additives. As the technique research deepens and its application gets more developed, the design of printing materials suitable for different applications is becoming the hotspot. Specifically, these materials not only can be photocured but also have excellent properties, such as elasticity, tear resistance, fatigue resistance. Photosensitive polyurethanes can endow photocured resin with desirable performance due to their unique molecular structure including the inherent alternating soft and hard segments, and microphase separation. For this reason, this review summarizes and comments on the research and application progress of photocurable 3D printing of photosensitive polyurethanes, analyzing the advantages and shortcomings of this technology, also offering an outlook on this rapid development direction.
Collapse
Affiliation(s)
- Jianhua Fei
- Key Laboratory of Medical Metal Materials of Shanxi Province, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, 030024, P. R. China
| | - Youjie Rong
- Key Laboratory of Medical Metal Materials of Shanxi Province, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, 030024, P. R. China
| | - Lisheng Zhu
- Key Laboratory of Medical Metal Materials of Shanxi Province, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, 030024, P. R. China
| | - Huijie Li
- Key Laboratory of Medical Metal Materials of Shanxi Province, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, 030024, P. R. China
| | - Xiaomin Zhang
- Key Laboratory of Medical Metal Materials of Shanxi Province, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, 030024, P. R. China
| | - Ying Lu
- Key Laboratory of Medical Metal Materials of Shanxi Province, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, 030024, P. R. China
- Shanxi Bethune Hospital, Shanxi Academy of Medical Science, Taiyuan, 030032, P. R. China
| | - Jian An
- Shanxi Coal Center Hospital, Taiyuan, 030006, P. R. China
- Department of Cardiology, Cardiovascular Hospital Affiliated to Shanxi Medical University, Taiyuan, 030001, P. R. China
| | - Qingbo Bao
- Shanxi Coal Center Hospital, Taiyuan, 030006, P. R. China
- Department of Cardiology, Cardiovascular Hospital Affiliated to Shanxi Medical University, Taiyuan, 030001, P. R. China
| | - Xiaobo Huang
- Key Laboratory of Medical Metal Materials of Shanxi Province, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, 030024, P. R. China
| |
Collapse
|
14
|
Idrees M, Yoon H, Palmese GR, Alvarez NJ. Engineering Toughness in a Brittle Vinyl Ester Resin Using Urethane Acrylate for Additive Manufacturing. Polymers (Basel) 2023; 15:3501. [PMID: 37688126 PMCID: PMC10490117 DOI: 10.3390/polym15173501] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 08/10/2023] [Accepted: 08/14/2023] [Indexed: 09/10/2023] Open
Abstract
Thermosetting polymers tend to have a stiffness-toughness trade-off due to the opposing relationship of stiffness and toughness on crosslink density. We hypothesize that engineering the polymer network, e.g., by incorporating urethane oligomers, we can improve the toughness by introducing variations in crosslink density. In this work, we show that a brittle methacrylated Bis-GMA resin (known as DA2) is toughened by adding a commercial urethane acrylate resin (known as Tenacious) in different proportions. The formulations are 3D printed using a vat photopolymerization technique, and their mechanical, thermal, and fracture properties are investigated. Our results show that a significant amount of Tenacious 60% w/w is required to produce parts with improved toughness. However, mechanical properties drop when the Tenacious amount is higher than 60% w/w. Overall, our results show that optimizing the amount of urethane acrylate can improve toughness without significantly sacrificing mechanical properties. In fact, the results show that synergistic effects in modulus and strength exist at specific blend concentrations.
Collapse
Affiliation(s)
| | | | | | - Nicolas J. Alvarez
- Department of Chemical and Biological Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA (G.R.P.)
| |
Collapse
|
15
|
Zainuddin MZ, Abu Bakar AA, Adam AN, Abdullah SM, Tamchek N, Alauddin MS, Mahat MM, Wiwatcharagoses N, Alforidi A, Ghazali MIM. Mechanical and Structural Properties of Polyhydroxybutyrate as Additive in Blend Material in Additive Manufacturing for Medical Applications. Polymers (Basel) 2023; 15:polym15081849. [PMID: 37111996 PMCID: PMC10145977 DOI: 10.3390/polym15081849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 03/24/2023] [Accepted: 04/05/2023] [Indexed: 04/29/2023] Open
Abstract
Today, additive manufacturing (AM) is considered one of the vital tenets of the industry 4.0 revolution due to its high productivity, decentralized production and rapid prototyping. This work aims to study the mechanical and structural properties of polyhydroxybutyrate as an additive in blend materials and its potential in medical applications. PHB/PUA blend resins were formulated with 0 wt.%, 6 wt.%, 12 wt.% and 18 wt.% of PHB concentration. Stereolithography or an SLA 3D printing technique were used to evaluate the printability of the PHB/PUA blend resins. Additionally, from FESEM analysis, a change was observed in PUA's microstructure, with an additional number of voids spotted. Furthermore, from XRD analysis, as PHB concentration increased, the crystallinity index (CI) also increased. This indicates the brittleness properties of the materials, which correlated to the weak performance of the tensile and impact properties. Next, the effect of PHB loading concentration within PHB/PUA blends and aging duration towards the mechanical performance of tensile and impact properties was also studied by using analysis of variance (ANOVA) with a two-way method. Finally, 12 wt.% of PHB/PUA was selected to 3D print the finger splint due to its characteristics, which are compatible to be used in finger bone fracture recovery.
Collapse
Affiliation(s)
- Muhammad Zulhilmi Zainuddin
- SMART RG, Faculty of Science and Technology (FST), Universiti Sains Islam Malaysia (USIM), Nilai 71800, Malaysia
| | - Ahmad Adnan Abu Bakar
- SMART RG, Faculty of Science and Technology (FST), Universiti Sains Islam Malaysia (USIM), Nilai 71800, Malaysia
| | - Ahmad Nurhelmy Adam
- SMART RG, Faculty of Science and Technology (FST), Universiti Sains Islam Malaysia (USIM), Nilai 71800, Malaysia
| | - Shahino Mah Abdullah
- SMART RG, Faculty of Science and Technology (FST), Universiti Sains Islam Malaysia (USIM), Nilai 71800, Malaysia
| | - Nizam Tamchek
- Department of Physics, Faculty of Science, Universiti Putra Malaysia (UPM), Serdang 43400, Malaysia
| | - Muhammad Syafiq Alauddin
- SMART RG, Faculty of Science and Technology (FST), Universiti Sains Islam Malaysia (USIM), Nilai 71800, Malaysia
- Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Universiti Sains Islam Malaysia, Kuala Lumpur 55100, Malaysia
| | - Mohd Muzamir Mahat
- Faculty of Applied Sciences, Universiti Teknologi Mara, Shah Alam 40450, Selangor, Malaysia
| | - Nophadon Wiwatcharagoses
- Department of Electrical and Computer Engineering, King Mongkut's University of Technology North Bangkok (KMUTNB) 1518 Pracharat 1 Road, Bangkok 10800, Thailand
| | - Ahmad Alforidi
- Electrical Engineering Department, Taibah University, Medina 42353, Saudi Arabia
| | - Mohd Ifwat Mohd Ghazali
- SMART RG, Faculty of Science and Technology (FST), Universiti Sains Islam Malaysia (USIM), Nilai 71800, Malaysia
| |
Collapse
|
16
|
Degree of conversion of 3D printing resins used for splints and orthodontic appliances under different postpolymerization conditions. Clin Oral Investig 2023:10.1007/s00784-023-04893-8. [PMID: 36757463 DOI: 10.1007/s00784-023-04893-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 02/01/2023] [Indexed: 02/10/2023]
Abstract
OBJECTIVES To measure the degree of conversion (DC) of different 3D printing resins used for splints or orthodontic appliances under different postpolymerization conditions. MATERIALS AND METHODS Five 3D-printed photopolymer resins were studied. Each resin was analyzed in liquid form (n = 15), and then cylindrical specimens (n = 135) were additively manufactured and postcured with Form Cure (Formlabs) at different times (10, 60, and 90 min) and temperatures (20 °C, 60 °C, and 80 °C). The DC of each specimen was measured with Fourier transform infrared spectroscopy (FTIR). The data were statistically analyzed using a 3-way ANOVA followed by Tukey's post hoc test. RESULTS The time and temperature of postpolymerization significantly influenced the DC of each resin: when time and/or temperature increased, the DC increased. For all resins tested, the lowest DC was obtained with a postcuring protocol at 10 min and 20 °C, and the highest DC was obtained at 90 min and 80 °C. However, at 80 °C, the samples showed a yellowish color. CONCLUSIONS With the Form Cure device, the time and temperature of postcuring could have an impact on the DC of the 3D printing resins studied. The DC of the 3D printing resins could be optimized by adjusting the postpolymerization protocol. CLINICAL RELEVANCE Regardless of the resin used, when using the Form Cure device, postcuring at 60 min and 60 °C would be the minimal time and temperature conditions for achieving proper polymerization. Beyond that, it would be preferable to increase the postcuring time to boost the DC.
Collapse
|
17
|
Thurzo A, Šufliarsky B, Urbanová W, Čverha M, Strunga M, Varga I. Pierre Robin Sequence and 3D Printed Personalized Composite Appliances in Interdisciplinary Approach. Polymers (Basel) 2022; 14:polym14183858. [PMID: 36146014 PMCID: PMC9500754 DOI: 10.3390/polym14183858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/09/2022] [Accepted: 09/13/2022] [Indexed: 11/16/2022] Open
Abstract
This paper introduces a complex novel concept and methodology for the creation of personalized biomedical appliances 3D-printed from certified biocompatible photopolymer resin Dental LT Clear (V2). The explained workflow includes intraoral and CT scanning, patient virtualization, digital appliance design, additive manufacturing, and clinical application with evaluation of the appliance intended for patients with cranio-facial syndromes. The presented concept defines virtual 3D fusion of intraoral optical scan and segmented CT as sufficient and accurate data defining the 3D surface of the face, intraoral and airway morphology necessary for the 3D design of complex personalized intraoral and extraoral parts of the orthopedic appliance. A central aspect of the concept is a feasible utilization of composite resin for biomedical prototyping of the sequence of marginally different appliances necessary to keep the pace with the patient rapid growth. Affordability, noninvasiveness, and practicality of the appliance update process shall be highlighted. The methodology is demonstrated on a particular case of two-year-old infant with Pierre Robin sequence. Materialization by additive manufacturing of this photopolymer provides a highly durable and resistant-to-fracture two-part appliance similar to a Tübingen palatal plate, for example. The paper concludes with the viability of the described method and material upon interdisciplinary clinical evaluation of experts from departments of orthodontics and cleft anomalies, pediatric pneumology and phthisiology, and pediatric otorhinolaryngology.
Collapse
Affiliation(s)
- Andrej Thurzo
- Department of Stomatology and Maxillofacial Surgery, Faculty of Medicine, Comenius University in Bratislava, 81250 Bratislava, Slovakia
- Correspondence: ; Tel.: +421-903-110-107
| | - Barbora Šufliarsky
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine, Comenius University in Bratislava and University Hospital, 81372 Bratislava, Slovakia
| | - Wanda Urbanová
- Department of Orthodontics and Cleft Anomalies, Faculty Hospital Kralovske Vinohrady, Dental Clinic 3rd Medical Faculty Charles University, 10034 Prague, Czech Republic
| | - Martin Čverha
- Clinic of Pediatric Otorhinolaryngology of the Medical Faculty Comenius University in Bratislava, 83340 Bratislava, Slovakia
| | - Martin Strunga
- Department of Stomatology and Maxillofacial Surgery, Faculty of Medicine, Comenius University in Bratislava, 81250 Bratislava, Slovakia
| | - Ivan Varga
- Department of Histology and Embryology, Faculty of Medicine, Comenius University in Bratislava, 81372 Bratislava, Slovakia
| |
Collapse
|
18
|
Tigmeanu CV, Ardelean LC, Rusu LC, Negrutiu ML. Additive Manufactured Polymers in Dentistry, Current State-of-the-Art and Future Perspectives-A Review. Polymers (Basel) 2022; 14:3658. [PMID: 36080732 PMCID: PMC9460687 DOI: 10.3390/polym14173658] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 08/21/2022] [Accepted: 09/01/2022] [Indexed: 11/16/2022] Open
Abstract
3D-printing application in dentistry not only enables the manufacture of patient-specific devices and tissue constructs, but also allows mass customization, as well as digital workflow, with predictable lower cost and rapid turnaround times. 4D printing also shows a good impact in dentistry, as it can produce dynamic and adaptable materials, which have proven effective in the oral environment, under its continuously changing thermal and humidity conditions. It is expected to further boost the research into producing a whole tooth, capable to harmoniously integrate with the surrounding periodontium, which represents the ultimate goal of tissue engineering in dentistry. Because of their high versatility associated with the wide variety of available materials, additive manufacturing in dentistry predominantly targets the production of polymeric constructs. The aim of this narrative review is to catch a glimpse of the current state-of-the-art of additive manufacturing in dentistry, and the future perspectives of this modern technology, focusing on the specific polymeric materials.
Collapse
Affiliation(s)
- Codruta Victoria Tigmeanu
- Department of Technology of Materials and Devices in Dental Medicine, Faculty of Dental Medicine, Multidisciplinary Center for Research, Evaluation, Diagnosis and Therapies in Oral Medicine, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania
| | - Lavinia Cosmina Ardelean
- Department of Technology of Materials and Devices in Dental Medicine, Faculty of Dental Medicine, Multidisciplinary Center for Research, Evaluation, Diagnosis and Therapies in Oral Medicine, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania
| | - Laura-Cristina Rusu
- Department of Oral Pathology, Faculty of Dental Medicine, Multidisciplinary Center for Research, Evaluation, Diagnosis and Therapies in Oral Medicine, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania
| | - Meda-Lavinia Negrutiu
- Department of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, Research Center in Dental Medicine Using Conventional and Alternative Technologies, “Victor Babes” University of Medicine and Pharmacy Timisoara, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania
| |
Collapse
|
19
|
Andjela L, Abdurahmanovich VM, Vladimirovna SN, Mikhailovna GI, Yurievich DD, Alekseevna MY. A review on Vat Photopolymerization 3D-printing processes for dental application. Dent Mater 2022; 38:e284-e296. [DOI: 10.1016/j.dental.2022.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 09/19/2022] [Accepted: 09/22/2022] [Indexed: 11/03/2022]
|
20
|
Bakhshi H, Kuang G, Wieland F, Meyer W. Photo-Curing Kinetics of 3D-Printing Photo-Inks Based on Urethane-Acrylates. Polymers (Basel) 2022; 14:2974. [PMID: 35893938 PMCID: PMC9331891 DOI: 10.3390/polym14152974] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 07/20/2022] [Accepted: 07/21/2022] [Indexed: 11/16/2022] Open
Abstract
In this study, photo-curing kinetics for urethane-acrylate-based photo-inks for 3D printing were evaluated using a photo-differential scanning calorimetry analysis. Initially, the photopolymerization kinetics of di- and monofunctional monomers were separately studied at different temperatures (5-85 °C). Later, the photo-curing kinetics and mechanical properties of photo-inks based on different monomer mixtures (40/60-20/80) were evaluated. The results showed that urethane-dimethacrylate (UrDMA) and urethane-acrylate (UrA) had no light absorption in the region of 280-700 nm, making them a proper crosslinker and a reactive diluent, respectively, for the formulation of 3D-printing photo-inks. The kinetics investigations showed a temperature dependency for the photo-curing of UrDMA, where a higher photopolymerization rate (Rp,max: from 5.25 × 10-2 to 8.42 × 10-2 1/s) and double-bound conversion (DBCtotal: from 63.8% to 92.2%) were observed at elevated temperatures (5-85 °C), while the photo-curing of UrA was independent of the temperature (25-85 °C). Enhancing the UrA content from 60% to 80% in the UrDMA/UrA mixtures initially increased and later decreased the photopolymerization rate and conversion, where the mixtures of 30/70 and 25/75 presented the highest values. Meanwhile, increasing the UrA content led to lower glass transition temperatures (Tg) and mechanical strength for the photo-cured samples, where the mixture of 30/70 presented the highest maximum elongation (εmax: 73%).
Collapse
Affiliation(s)
- Hadi Bakhshi
- Department of Life Science and Bioprocesses, Fraunhofer Institute for Applied Polymer Research IAP, Geiselbergstraße 69, 14476 Potsdam, Germany;
- Department of Functional Polymer Systems, Fraunhofer Institute for Applied Polymer Research IAP, Geiselbergstraße 69, 14476 Potsdam, Germany; (G.K.); (F.W.)
| | - Guanxing Kuang
- Department of Functional Polymer Systems, Fraunhofer Institute for Applied Polymer Research IAP, Geiselbergstraße 69, 14476 Potsdam, Germany; (G.K.); (F.W.)
| | - Franziska Wieland
- Department of Functional Polymer Systems, Fraunhofer Institute for Applied Polymer Research IAP, Geiselbergstraße 69, 14476 Potsdam, Germany; (G.K.); (F.W.)
| | - Wolfdietrich Meyer
- Department of Life Science and Bioprocesses, Fraunhofer Institute for Applied Polymer Research IAP, Geiselbergstraße 69, 14476 Potsdam, Germany;
- Department of Functional Polymer Systems, Fraunhofer Institute for Applied Polymer Research IAP, Geiselbergstraße 69, 14476 Potsdam, Germany; (G.K.); (F.W.)
| |
Collapse
|
21
|
Bürgers R, Schubert A, Müller J, Krohn S, Rödiger M, Leha A, Wassmann T. Cytotoxicity of 3D‐printed, milled, and conventional oral splint resins to L929 cells and human gingival fibroblasts. Clin Exp Dent Res 2022; 8:650-657. [PMID: 35570327 PMCID: PMC9209804 DOI: 10.1002/cre2.592] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Accepted: 05/01/2022] [Indexed: 11/22/2022] Open
Abstract
Objectives Evidence on the biocompatibility of three‐dimensional (3D)‐printed and milled resins for oral splints is limited. This in vitro study assessed the influence of the manufacturing method on the cytotoxicity of oral splint resins on L929 cells and human gingival fibroblasts (GF1). Materials and Methods Standardized specimens of four 3D‐printed, two‐milled, one‐thermoformed, and one‐pressed splint resin were incubated with L929 and GF1 cells for 24 h. Immunofluorescence and WST‐8 assay were performed to evaluate cytotoxic effects. One‐way analysis of variance and Tukey's multiple comparison test were applied with the variables “splint resin” and “manufacturing method” (p < .05). Results Immunofluorescence showed attachment of L929 and GF1 cells to the splint resins. Irrespective of the manufacturing method, the WST‐8 assay revealed significant differences between splint resins for the viability of L929 and GF1 cells. L929 cells generally showed lower viability rates than GF1 cells. The evaluation of cell viability by the manufacturing method showed no significant differences between 3D printing, milling, and conventional methods. Conclusions The cytotoxic effects of 3D‐printed, milled, and conventional oral splint resins were similar, indicating minor influence of the manufacturing method on biocompatibility. Cytotoxicity of the resins was below a critical threshold in GF1 cells. The chemical composition might be more crucial than the manufacturing method for the biocompatibility of splint resins.
Collapse
Affiliation(s)
- Ralf Bürgers
- Department of ProsthodonticsUniversity Medical Center GöttingenGöttingenGermany
| | - Andrea Schubert
- Department of ProsthodonticsUniversity Medical Center GöttingenGöttingenGermany
| | - Jonas Müller
- Department of ProsthodonticsUniversity Medical Center GöttingenGöttingenGermany
| | - Sebastian Krohn
- Department of ProsthodonticsUniversity Medical Center GöttingenGöttingenGermany
| | - Matthias Rödiger
- Department of ProsthodonticsUniversity Medical Center GöttingenGöttingenGermany
| | - Andreas Leha
- Department of Medical StatisticsUniversity Medical Center GöttingenGöttingenGermany
| | - Torsten Wassmann
- Department of ProsthodonticsUniversity Medical Center GöttingenGöttingenGermany
| |
Collapse
|
22
|
3D-Printed vs. Heat-Polymerizing and Autopolymerizing Denture Base Acrylic Resins. MATERIALS 2021; 14:ma14195781. [PMID: 34640178 PMCID: PMC8510326 DOI: 10.3390/ma14195781] [Citation(s) in RCA: 51] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 09/24/2021] [Accepted: 09/30/2021] [Indexed: 11/17/2022]
Abstract
The aim of this work was to investigate the effect of two post-curing methods on the mechanical properties of a 3D-printed denture base material. Additionally, to compare the mechanical properties of that 3D-printed material with those of conventional autopolymerizing and a heat-cured denture base material. A resin for 3D-printing denture base (Imprimo®), a heat-polymerizing acrylic resin (Paladon® 65), and an autopolymerizing acrylic resin (Palapress®) were investigated. Flexural strength, elastic modulus, fracture toughness, work of fracture, water sorption, and water solubility were evaluated. The 3D-printed test specimens were post-cured using two different units (Imprimo Cure® and Form Cure®). The tests were carried out after both dry and 30 days water storage. Data were collected and statistically analyzed. Resin type had a significant effect on the flexural strength, elastic modulus, fracture toughness, and work of fracture (p < 0.001). The flexural strength and elastic modulus for the heat-cured polymer were significantly the highest among all investigated groups regardless of the storage condition (p < 0.001). The fracture toughness and work of fracture of the 3D-printed material were significantly the lowest (p < 0.001). The heat-cured polymer had the lowest significant water solubility (p < 0.001). The post-curing method had an impact on the flexural strength of the investigated 3D-printed denture base material. The flexural strength, elastic modulus, fracture toughness, work of fracture of the 3D-printed material were inferior to those of the heat-cured one. Increased post-curing temperature may enhance the flexural properties of resin monomers used for 3D-printing dental appliances.
Collapse
|
23
|
Abstract
Fabrication of complete dentures (CDs) utilizing computer-aided design and computer-aided manufacturing (CAD/CAM) methods has attracted a lot of attention. The purpose of this paper was to summarize current knowledge about digital CDs and the relevant technology, and to present the application of the new technology in a dental geriatrics case. Initially, some of the challenges regarding digitization of the oral mucosa as a supporting surface of the CDs’ intaglio surface are listed. Next, a brief introduction of the CAD software capabilities regarding CDs is presented. The latest CAM additive and subtractive techniques for CDs are following. Subsequently, the consecutive steps for the construction of a digital CD as part of the prosthodontic treatment of a 90-year-old ambulative female patient are presented. Finally, some considerations about the digital workflow in CD manufacturing are discussed. In conclusion, the new digital technology has clear advantages; however, implementation requires careful planning. The digital workflow is applicable and versatile.
Collapse
|