1
|
Khan MDFH, Youssef M, Nesdoly S, Kamen AA. Development of Robust Freeze-Drying Process for Long-Term Stability of rVSV-SARS-CoV-2 Vaccine. Viruses 2024; 16:942. [PMID: 38932234 PMCID: PMC11209311 DOI: 10.3390/v16060942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 06/01/2024] [Accepted: 06/07/2024] [Indexed: 06/28/2024] Open
Abstract
The thermostability of vaccines, particularly enveloped viral vectored vaccines, remains a challenge to their delivery wherever needed. The freeze-drying of viral vectored vaccines is a promising approach but remains challenging due to the water removal process from the outer and inner parts of the virus. In the case of enveloped viruses, freeze-drying induces increased stress on the envelope, which often leads to the inactivation of the virus. In this study, we designed a method to freeze-dry a recombinant vesicular stomatitis virus (VSV) expressing the SARS-CoV-2 spike glycoprotein. Since the envelope of VSV is composed of 50% lipids and 50% protein, the formulation study focused on both the protein and lipid portions of the vector. Formulations were prepared primarily using sucrose, trehalose, and sorbitol as cryoprotectants; mannitol as a lyoprotectant; and histidine as a buffer. Initially, the infectivity of rVSV-SARS-CoV-2 and the cake stability were investigated at different final moisture content levels. High recovery of the infectious viral titer (~0.5 to 1 log loss) was found at 3-6% moisture content, with no deterioration in the freeze-dried cakes. To further minimize infectious viral titer loss, the composition and concentration of the excipients were studied. An increase from 5 to 10% in both the cryoprotectants and lyoprotectant, together with the addition of 0.5% gelatin, resulted in the improved recovery of the infectious virus titer and stable cake formation. Moreover, the secondary drying temperature of the freeze-drying process showed a significant impact on the infectivity of rVSV-SARS-CoV-2. The infectivity of the vector declined drastically when the temperature was raised above 20 °C. Throughout a long-term stability study, formulations containing 10% sugar (sucrose/trehalose), 10% mannitol, 0.5% gelatin, and 10 mM histidine showed satisfactory stability for six months at 2-8 °C. The development of this freeze-drying process and the optimized formulation minimize the need for a costly cold chain distribution system.
Collapse
Affiliation(s)
| | | | | | - Amine A. Kamen
- Viral Vectors and Vaccines Bioprocessing Group, Department of Bioengineering, McGill University, Montreal, QC H2X 1Y4, Canada; (M.F.H.K.)
| |
Collapse
|
2
|
Emerging PAT for Freeze-Drying Processes for Advanced Process Control. Processes (Basel) 2022. [DOI: 10.3390/pr10102059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Lyophilization is a widely used drying operation, but long processing times are a major drawback. Most lyophilization processes are conducted by a recipe that is not changed or optimized after implementation. With the regulatory demanded quality by design (QbD) approach, the process can be controlled inside an optimal range, ensuring safe process conditions. Process analytical technology (PAT) is crucial because it allows real-time monitoring and is part of a control strategy. In this work, emerging PAT (manometric temperature measurement (MTM), comparative pressure measurement, heat flux sensors, and ice ruler) are used for measurements during the freeze-drying process, and their potential for implementation inside a control strategy is outlined.
Collapse
|
3
|
Process Automation and Control Strategy by Quality-by-Design in Total Continuous mRNA Manufacturing Platforms. Processes (Basel) 2022. [DOI: 10.3390/pr10091783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Vaccine supply has a bottleneck in manufacturing capacity due to operation personnel and chemicals needed. Assessment of existing mRNA (messenger ribonucleic acid) vaccine processing show needs for continuous manufacturing processes. This is enabled by strict application of the regulatory demanded quality by design process based on digital twins, process analytical technology, and control automation strategies in order to improve process transfer for manufacturing capacity, reduction out-of-specification batch failures, qualified personnel training and number, optimal utilization of buffers and chemicals as well as speed-up of product release. In this work, process control concepts, which are necessary for achieving autonomous, continuous manufacturing, for mRNA manufacturing are explained and proven to be ready for industrialization. The application of the process control strategies developed in this work enable the previously pointed out benefits. By switching from batch-wise to continuous mRNA production as was shown in previous work, which was the base for this study, a potential cost reduction by a factor 5 (i.e., from EUR 0.380 per dose to EUR 0.085 per dose) is achievable. Mainly, based on reduction of personnel (factor 30) and consumable (factor 7.5) per campaign due to the significant share of raw materials in the manufacturing costs (74–97). Future research focus following this work may be on model-based predictive control to gain further optimization potential of potential batch failure and out of specification (OOS) number reduction.
Collapse
|
4
|
Juckers A, Knerr P, Harms F, Strube J. Emerging process analytical technology (PAT) for characterization of freeze‐drying processes. CHEM-ING-TECH 2022. [DOI: 10.1002/cite.202255089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- A. Juckers
- Clausthal University of Technology Institute for Separation and Process Technology Leibnizstr. 15 38678 Clausthal-Zellerfeld Germany
- Martin Christ Gefriertrocknungsanlagen GmbH An der Unteren Söse 50 37520 Osterode Germany
| | - P. Knerr
- Martin Christ Gefriertrocknungsanlagen GmbH An der Unteren Söse 50 37520 Osterode Germany
| | - F. Harms
- Martin Christ Gefriertrocknungsanlagen GmbH An der Unteren Söse 50 37520 Osterode Germany
| | - J. Strube
- Clausthal University of Technology Institute for Separation and Process Technology Leibnizstr. 15 38678 Clausthal-Zellerfeld Germany
| |
Collapse
|
5
|
Abstract
The development and adoption of digital twins (DT) for Quality-by-Design (QbD)-based processes with flexible operating points within a proven acceptable range (PAR) and automation through Advanced Process Control (APC) with Process Analytical Technology (PAT) instead of conventional process execution based on offline analytics and inflexible process set points is one of the great challenges in modern biotechnology. Virus-like particles (VLPs) are part of a line of innovative drug substances (DS). VLPs, especially those based on human immunodeficiency virus (HIV), HIV-1 Gag VLPs, have very high potential as a versatile vaccination platform, allowing for pseudotyping with heterologous envelope proteins, e.g., the S protein of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). As enveloped VLPs, optimal process control with minimal hold times is essential. This study demonstrates, for the first time, the use of a digital twin for the overall production process of HIV-1 Gag VLPs from cultivation, clarification, and purification to lyophilization. The accuracy of the digital twins is in the range of 0.8 to 1.4% in depth filtration (DF) and 4.6 to 5.2% in ultrafiltration/diafiltration (UFDF). The uncertainty due to variability in the model parameter determination is less than 4.5% (DF) and less than 3.8% (UFDF). In the DF, a prediction of the final filter capacity was demonstrated from as low as 5.8% (9mbar) of the final transmembrane pressure (TMP). The scale-up based on DT in chromatography shows optimization potential in productivity up to a factor of 2. The schedule based on DT and PAT for APC has been compared to conventional process control, and hold-time and process duration reductions by a factor of 2 have been achieved. This work lays the foundation for the short-term validation of the DT and PAT for APC in an automated S7 process environment and the conversion from batch to continuous production.
Collapse
|
6
|
Abstract
Quality-by-Design (QbD) is demanded by regulatory authorities in biopharmaceutical production. Within the QbD frame advanced process control (APC), facilitated through process analytical technology (PAT) and digital twins (DT), plays an increasingly important role as it can help to assure to stay within the predefined proven acceptable range (PAR).This ensures high product quality, minimizes failure and is an important step towards a real-time-release testing (RTRT) that could help to accelerate time-to-market of drug substances, which is becoming even more important in light of dynamical pandemic situations. The approach is exemplified on scFv manufacturing in Escherichia coli. Simulation results from digital twins are compared to experimental data and found to be accurate and precise. Harvest is achieved by tangential flow filtration followed by product release through high pressure homogenization and subsequent clarification by tangential flow filtration. Digital twins of the membrane processes show that shear rate and transmembrane pressure are significant process parameters, which is in line with experimental data. Optimized settings were applied to 0.3 bar and a shear rate of 11,000 s−1. Productivity of chromatography steps were 5.3 g/L/d (Protein L) and 2167 g/L/d (CEX) and the final product concentration was 8 g/L. Based on digital twin results, an optimized process schedule was developed that decreased purification time to one working day, which is a factor-two reduction compared to the conventional process schedule. This work presents the basis for future studies on advanced process control and automation for biologics production in microbials in regulated industries.
Collapse
|
7
|
Juckers A, Knerr P, Harms F, Strube J. Model-Based Product Temperature and Endpoint Determination in Primary Drying of Lyophilization Processes. Pharmaceutics 2022; 14:pharmaceutics14040809. [PMID: 35456643 PMCID: PMC9031979 DOI: 10.3390/pharmaceutics14040809] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 03/31/2022] [Accepted: 04/05/2022] [Indexed: 11/21/2022] Open
Abstract
Lyophilization process design still relies mainly on empirical studies with high experimental loads. In the regulatory demanded Quality by Design approach, process modeling is a key aspect. It allows process design, optimization and process control to ensure a safe process and product quality. A modeling approach is outlined that is able to predict the primary drying endpoint and temperature profile of distinct vials. Model parameters are determined by a reproducible determination concept. Simulated results are validated with a fractional factorial Design of Experiments (DoE) in pilot scale. The model shows higher accuracy and precision than the experiments and similar parameter interactions for both the endpoint and temperature determination. This approach can now be used to explore the primary design space in lyophilization process design. This paper proposes a distinct method for endpoint determination and product temperature prediction by a modeling approach based on Velardi et al. combined with a distinct model parameter determination according to Wegiel et al. and Tang et al.
Collapse
Affiliation(s)
- Alex Juckers
- Institute for Separation and Process Technology, Clausthal University of Technology, 38678 Clausthal-Zellerfeld, Germany;
- Martin Christ Gefriertrocknungsanlagen GmbH, 37520 Osterode am Harz, Germany; (P.K.); (F.H.)
| | - Petra Knerr
- Martin Christ Gefriertrocknungsanlagen GmbH, 37520 Osterode am Harz, Germany; (P.K.); (F.H.)
| | - Frank Harms
- Martin Christ Gefriertrocknungsanlagen GmbH, 37520 Osterode am Harz, Germany; (P.K.); (F.H.)
| | - Jochen Strube
- Institute for Separation and Process Technology, Clausthal University of Technology, 38678 Clausthal-Zellerfeld, Germany;
- Correspondence:
| |
Collapse
|
8
|
Process Design and Optimization towards Digital Twins for HIV-Gag VLP Production in HEK293 Cells, including Purification. Processes (Basel) 2022. [DOI: 10.3390/pr10020419] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Despite great efforts to develop a vaccine against human immunodeficiency virus (HIV), which causes AIDS if untreated, no approved HIV vaccine is available to date. A promising class of vaccines are virus-like particles (VLPs), which were shown to be very effective for the prevention of other diseases. In this study, production of HI-VLPs using different 293F cell lines, followed by a three-step purification of HI-VLPs, was conducted. The quality-by-design-based process development was supported by process analytical technology (PAT). The HI-VLP concentration increased 12.5-fold while >80% purity was achieved. This article reports on the first general process development and optimization up to purification. Further research will focus on process development for polishing and formulation up to lyophilization. In addition, process analytical technology and process modeling for process automation and optimization by digital twins in the context of quality-by-design framework will be developed.
Collapse
|
9
|
Wang J, Li X, Wang P, Liu Q. Bibliometric analysis of digital twin literature: a review of influencing factors and conceptual structure. TECHNOLOGY ANALYSIS & STRATEGIC MANAGEMENT 2022. [DOI: 10.1080/09537325.2022.2026320] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Jing Wang
- School of Economics and Management, China University of Mining and Technology, Xuzhou City, Jiangsu Province, People’s Republic of China
- Library, China University of Mining and Technology, Xuzhou City, Jiangsu Province, People’s Republic of China
| | - Xinchun Li
- School of Economics and Management, China University of Mining and Technology, Xuzhou City, Jiangsu Province, People’s Republic of China
| | - Peng Wang
- Library, China University of Mining and Technology, Xuzhou City, Jiangsu Province, People’s Republic of China
| | - Quanlong Liu
- School of Economics and Management, China University of Mining and Technology, Xuzhou City, Jiangsu Province, People’s Republic of China
| |
Collapse
|
10
|
Fast and Flexible mRNA Vaccine Manufacturing as a Solution to Pandemic Situations by Adopting Chemical Engineering Good Practice—Continuous Autonomous Operation in Stainless Steel Equipment Concepts. Processes (Basel) 2021. [DOI: 10.3390/pr9111874] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
SARS-COVID-19 vaccine supply for the total worldwide population has a bottleneck in manufacturing capacity. Assessment of existing messenger ribonucleic acid (mRNA) vaccine processing shows a need for digital twins enabled by process analytical technology approaches in order to improve process transfer for manufacturing capacity multiplication, a reduction in out-of-specification batch failures, qualified personal training for faster validation and efficient operation, optimal utilization of scarce buffers and chemicals and speed-up of product release by continuous manufacturing. In this work, three manufacturing concepts for mRNA-based vaccines are evaluated: Batch, full-continuous and semi-continuous. Technical transfer from batch single-use to semi-continuous stainless-steel, i.e., plasmid deoxyribonucleic acid (pDNA) in batch and mRNA in continuous operation mode, is recommended, in order to gain: faster plant commissioning and start-up times of about 8–12 months and a rise in dose number by a factor of about 30 per year, with almost identical efforts in capital expenditures (CAPEX) and personnel resources, which are the dominant bottlenecks at the moment, at about 25% lower operating expenses (OPEX). Consumables are also reduceable by a factor of 6 as outcome of this study. Further optimization potential is seen at consequent digital twin and PAT (Process Analytical Technology) concept integration as key-enabling technologies towards autonomous operation including real-time release-testing.
Collapse
|
11
|
Advanced Process Analytical Technology in Combination with Process Modeling for Endpoint and Model Parameter Determination in Lyophilization Process Design and Optimization. Processes (Basel) 2021. [DOI: 10.3390/pr9091600] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Lyophilization is widely used in the preservation of thermolabile products. The main shortcoming is the long processing time. Lyophilization processes are mostly based on a recipe that is not changed, but, with the Quality by Design (QbD) approach and use of Process Analytical Technology (PAT), the process duration can be optimized for maximum productivity while ensuring product safety. In this work, an advanced PAT approach is used for the endpoint determination of primary drying. Manometric temperature measurement (MTM) and comparative pressure measurement are used to determine the endpoint of the batch while a modeling approach is outlined that is able to calculate the endpoint of every vial in the batch. This approach can be used for process development, control and optimization.
Collapse
|
12
|
Digital Twin of mRNA-Based SARS-COVID-19 Vaccine Manufacturing towards Autonomous Operation for Improvements in Speed, Scale, Robustness, Flexibility and Real-Time Release Testing. Processes (Basel) 2021. [DOI: 10.3390/pr9050748] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Supplying SARS-COVID-19 vaccines in quantities to meet global demand has a bottleneck in manufacturing capacity. Assessment of existing mRNA (messenger ribonucleic acid) vaccine processing shows the need for digital twins enabled by process analytical technology approaches to improve process transfers for manufacturing capacity multiplication, reduction of out-of-specification batch failures, qualified personnel training for faster validation and efficient operation, optimal utilization of scarce buffers and chemicals, and faster product release. A digital twin of the total pDNA (plasmid deoxyribonucleic acid) to mRNA process is proposed. In addition, a first feasibility of multisensory process analytical technology (PAT) is shown. Process performance characteristics are derived as results and evaluated regarding manufacturing technology bottlenecks. Potential improvements could be pointed out such as dilution reduction in lysis, and potential reduction of necessary chromatography steps. 1 g pDNA may lead to about 30 g mRNA. This shifts the bottleneck towards the mRNA processing step, which points out co-transcriptional capping as a preferred option to reduce the number of purification steps. Purity demands are fulfilled by a combination of mixed-mode and reversed-phase chromatography as established unit operations on a higher industrial readiness level than e.g., precipitation and ethanol-chloroform extraction. As a final step, lyophilization was chosen for stability, storage and transportation logistics. Alternative process units like UF/DF (ultra-/diafiltration) integration would allow the adjustment of final concentration and buffer composition before lipid-nano particle (LNP) formulation. The complete digital twin is proposed for further validation in manufacturing scale and utilization in process optimization and manufacturing operations. The first PAT results should be followed by detailed investigation of different batches and processing steps in order to implement this strategy for process control and reliable, efficient operation.
Collapse
|
13
|
Towards Autonomous Operation by Advanced Process Control—Process Analytical Technology for Continuous Biologics Antibody Manufacturing. Processes (Basel) 2021. [DOI: 10.3390/pr9010172] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
Continuous manufacturing opens up new operation windows with improved product quality in contrast to documented lot deviations in batch or fed-batch operations. A more sophisticated process control strategy is needed to adjust operation parameters and keep product quality constant during long-term operations. In the present study, the applicability of a combination of spectroscopic methods was evaluated to enable Advanced Process Control (APC) in continuous manufacturing by Process Analytical Technology (PAT). In upstream processing (USP) and aqueous two-phase extraction (ATPE), Raman-, Fourier-transformed infrared (FTIR), fluorescence- and ultraviolet/visible- (UV/Vis) spectroscopy have been successfully applied for titer and purity prediction. Raman spectroscopy was the most versatile and robust method in USP, ATPE, and precipitation and is therefore recommended as primary PAT. In later process stages, the combination of UV/Vis and fluorescence spectroscopy was able to overcome difficulties in titer and purity prediction induced by overlapping side component spectra. Based on the developed spectroscopic predictions, dynamic control of unit operations was demonstrated in sophisticated simulation studies. A PAT development workflow for holistic process development was proposed.
Collapse
|