1
|
Ying Y, Cui X, Li H, Pan L, Luo T, Cao Z, Wang J. Development of Magnetic Lateral Flow and Direct Competitive Immunoassays for Sensitive and Specific Detection of Halosulfuron-Methyl Using a Novel Hapten and Monoclonal Antibody. Foods 2023; 12:2764. [PMID: 37509857 PMCID: PMC10378753 DOI: 10.3390/foods12142764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 07/12/2023] [Accepted: 07/14/2023] [Indexed: 07/30/2023] Open
Abstract
Halosulfuron-methyl (HM) is widely used for the removal of noxious weeds in corn, sugarcane, wheat, rice, and tomato fields. Despite its high efficiency and low toxicity, drift to nontarget crops and leaching of its metabolites to groundwater pose potential risks. Considering the instability of HM, the pyrazole sulfonamide of HM was used to generate a hapten and antigen to raise a high-quality monoclonal antibody (Mab, designated 1A91H11) against HM. A direct competitive immunoassay (dcELISA) using Mab 1A91H11 achieved a half-maximal inhibitory concentration (IC50) of 1.5 × 10-3 mg/kg and a linear range of 0.7 × 10-3 mg/kg-10.7 × 10-3 mg/kg, which was 10 times more sensitive than a comparable indirect competitive ELISA (icELISA) and more simple to operate. A spiking recovery experiment performed in tomato and maize matrices with 0.01, 0.05, and 0.1 mg/kg HM had average recoveries within 78.9-87.9% and 103.0-107.4% and coefficients of variation from 1.1-6.8% and 2.7-6.4% in tomato and maize, respectively. In addition, a magnetic lateral flow immunoassay (MLFIA) was developed for quantitative detection of low concentrations of HM in paddy water. Compared with dcELISA, the MLFIA exhibited 3.3- to 50-fold higher sensitivity (IC50 0.21 × 10-3 mg/kg). The average recovery and RSD of the developed MLFIA ranged from 81.5 to 92.5% and 5.4 to 9.7%. The results of this study demonstrated that the developed dcELISA and MLFIA are suitable for rapid detection of HM residues in tomato and maize matrices and paddy water, respectively, with acceptable accuracy and precision.
Collapse
Affiliation(s)
- Ying Ying
- Institute of Quality Standards and Testing Technology for Agro-Products, Key Laboratory of Agro-Product Quality and Safety, Chinese Academy of Agricultural Sciences, Ministry of Agriculture, Beijing 100081, China
- Institute of Quality Standards and Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Xueyan Cui
- Institute of Quality Standards and Testing Technology for Agro-Products, Key Laboratory of Agro-Product Quality and Safety, Chinese Academy of Agricultural Sciences, Ministry of Agriculture, Beijing 100081, China
- Institute of Quality Standards and Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Hui Li
- Institute of Quality Standards and Testing Technology for Agro-Products, Key Laboratory of Agro-Product Quality and Safety, Chinese Academy of Agricultural Sciences, Ministry of Agriculture, Beijing 100081, China
- Institute of Quality Standards and Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Lingyi Pan
- Institute of Quality Standards and Testing Technology for Agro-Products, Key Laboratory of Agro-Product Quality and Safety, Chinese Academy of Agricultural Sciences, Ministry of Agriculture, Beijing 100081, China
- Institute of Quality Standards and Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Ting Luo
- Institute of Quality Standards and Testing Technology for Agro-Products, Key Laboratory of Agro-Product Quality and Safety, Chinese Academy of Agricultural Sciences, Ministry of Agriculture, Beijing 100081, China
- Institute of Quality Standards and Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Zhen Cao
- Institute of Quality Standards and Testing Technology for Agro-Products, Key Laboratory of Agro-Product Quality and Safety, Chinese Academy of Agricultural Sciences, Ministry of Agriculture, Beijing 100081, China
- Institute of Quality Standards and Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Jing Wang
- Institute of Quality Standards and Testing Technology for Agro-Products, Key Laboratory of Agro-Product Quality and Safety, Chinese Academy of Agricultural Sciences, Ministry of Agriculture, Beijing 100081, China
- Institute of Quality Standards and Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| |
Collapse
|
2
|
Zhao Y, Sang J, Fu Y, Guo J, Guo J. Magnetic nanoprobe-enabled lateral flow assays: recent advances. Analyst 2023. [PMID: 37365935 DOI: 10.1039/d3an00044c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2023]
Abstract
In recent years, magnetic nanoparticle sensor technologies have attracted considerable interest in the point-of-care-testing (POCT) field, especially in lateral flow immunoassays (LFIAs). Although the visual signal of magnetic nanoparticles is reduced during an inspection, it can be compensated for by magnetic induction, and detection results can be quantified by magnetic sensors. Sensors that use magnetic nanoparticles (MNPs) as markers can overcome the high background noise of complex samples. In this study, MNP signal detection strategies are described from the perspectives of magnetoresistance, magnetic flux, frequency mixing technology, and magnetic permeability, and the principles and development of each technology are introduced in detail. Typical applications of magnetic nanoparticle sensor technologies are introduced. By describing the advantages and limitations of different sensing strategies, we highlight the development and improvement directions of different sensing strategies. In general, the future development of magnetic nanoparticle sensor technologies will be toward intelligent, convenient, and mobile high-performance detection equipment.
Collapse
Affiliation(s)
- Ying Zhao
- Institute of Respiratory Health, Frontiers Science Center for Disease-Related Molecular Network, Precision Medicine Key Laboratory of Sichuan Province, West China Hospital, Sichuan University, Chengdu, China
| | - Jingwei Sang
- University of Electronic Science and Technology of China, Chengdu 611731, China.
| | - Yusheng Fu
- University of Electronic Science and Technology of China, Chengdu 611731, China.
| | - Jiuchuan Guo
- University of Electronic Science and Technology of China, Chengdu 611731, China.
| | - Jinhong Guo
- School of Sensing Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
- The M.O.E. Key Laboratory of Laboratory Medical Diagnostics, The College of Laboratory Medicine, Chongqing Medical University, #1 Yixueyuan Road, Yuzhong District, Chongqing, 400016, China
| |
Collapse
|
3
|
Xu S, Ma B, Li J, Su W, Xu T, Zhang M. Europium Nanoparticles-Based Fluorescence Immunochromatographic Detection of Three Abused Drugs in Hair. TOXICS 2023; 11:toxics11050417. [PMID: 37235232 DOI: 10.3390/toxics11050417] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 04/19/2023] [Accepted: 04/26/2023] [Indexed: 05/28/2023]
Abstract
Drug abuse is becoming increasingly dangerous nowadays. Morphine (MOP), methamphetamine (MET) and ketamine (KET) are the most commonly abused drugs. The abuse of these drugs without supervision can cause serious harm to the human body and also endanger public safety. Developing a rapid and accurate method to screen drug suspects and thus control these drugs is essential to public safety. This paper presents a method for the simultaneous quantitative detection of these three drugs in hair by a europium nanoparticles-based fluorescence immunochromatographic assay (EuNPs-FIA). In our study, the test area of the nitrocellulose membrane was composed of three equally spaced detection lines and a quality control line. The test strip realized the quantitative analysis of the samples by detecting the fluorescence brightness of the europium nanoparticles captured on the test line within 15 min. For the triple test strip, the limits of detection of MOP, KET and MET were 0.219, 0.079 and 0.329 ng/mL, respectively. At the same time, it also showed strong specificity. The strip was stable and could be stored at room temperature for up to one year, and the average recovery rate was 85.98-115.92%. In addition, the EuNPs-FIA was validated by high-performance liquid chromatography (HPLC) analysis, and a satisfactory consistency was obtained. Compared to the current immunochromatographic methods used for detecting abused drugs in hair, this method not only increased the number of detection targets, but also ensured sensitivity, improving detection efficiency to a certain extent. The approach can also be used as an alternative to chromatography. It provides a rapid and accurate screening method for the detection of abused drugs in hair and has great application prospects in regard to public safety.
Collapse
Affiliation(s)
- Shujuan Xu
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
| | - Biao Ma
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
| | - Jiali Li
- Hangzhou Quickgene Sci-Tech. Co., Ltd., Hangzhou 310018, China
| | - Wei Su
- Wenzhou MeiZhong Medical Laboratory, Wenzhou 325000, China
| | - Tianran Xu
- College of Life Science, China Jiliang University, Hangzhou 310018, China
| | - Mingzhou Zhang
- Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
| |
Collapse
|
4
|
Nan X, Yang L, Cui Y. Lateral Flow Immunoassay for Proteins. Clin Chim Acta 2023; 544:117337. [PMID: 37044163 DOI: 10.1016/j.cca.2023.117337] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 04/07/2023] [Accepted: 04/07/2023] [Indexed: 04/14/2023]
Abstract
Protein biomarkers are useful for disease diagnosis. Identification thereof using in vitro diagnostics such as lateral flow immunoassays (LFIAs) has attracted considerable attention due to their low cost and ease of use especially in the point of care setting. Current challenges, however, do remain with respect to material selection for each component in the device and the synergistic integration of these components to display detectable signals. This review explores the principle of LFIA for protein biomarkers, device components including biomaterials and labeling methods. Medical applications and commercial status are examined as well. This review highlights critical methodologies in the development of new LFIAs and their role in advancing healthcare worldwide.
Collapse
Affiliation(s)
- Xuanxu Nan
- School of Materials Science and Engineering, Peking University; First Hospital Interdisciplinary Research Center, Peking University, Beijing 100871, P.R. China
| | - Li Yang
- Renal Division, Peking University First Hospital; Peking University Institute of Nephrology; Key Laboratory of Renal Disease, Ministry of Health of China; Key Laboratory of Chronic Kidney Disease Prevention and Treatment (Peking University), Ministry of Education, Beijing 100034, P. R. China.
| | - Yue Cui
- School of Materials Science and Engineering, Peking University; First Hospital Interdisciplinary Research Center, Peking University, Beijing 100871, P.R. China.
| |
Collapse
|
5
|
Ghasemi F, Fahimi-Kashani N, Bigdeli A, Alshatteri AH, Abbasi-Moayed S, Al-Jaf SH, Merry MY, Omer KM, Hormozi-Nezhad MR. Paper-based optical nanosensors – A review. Anal Chim Acta 2022; 1238:340640. [DOI: 10.1016/j.aca.2022.340640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022]
|
6
|
Current Trends and Challenges in Point-of-care Urinalysis of Biomarkers in Trace Amounts. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
7
|
Raj N, Crooks RM. Plastic-based lateral flow immunoassay device for electrochemical detection of NT-proBNP. Analyst 2022; 147:2460-2469. [PMID: 35531909 PMCID: PMC9178520 DOI: 10.1039/d2an00685e] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/23/2023]
Abstract
Here we report an easily fabricated, plastic-based lateral flow device for carrying out metalloimmunoassays. The device is called ocFlow to emphasize the open-channel design. We have shown that the ocFlow is capable of magnetic microbead (MμB)-based metalloimmunoassays for the detection of two types of immunoconjugates: a model composite (MC) and a sandwich immunoassay for the heart failure marker NT-proBNP. In both assays, Ag nanoparticles (AgNPs) were used as electrochemically detectable labels. NT-proBNP and MC concentrations as low as 750.0 pM and 10.0 pM, respectively, could be detected using the ocFlow device. Four key conclusions can be drawn from the results presented herein. First, immunoconjugates attached to the MμBs can be transported in the flow channel using combined hydrodynamic and capillary pressure passive pumping. Second, the ocFlow device is capable of on-chip storage, resolvation, and conjugate formation of both the MC and NT-proBNP composites. Third, electrochemical detection can be conducted on analytes suspended in serum by rinsing the electrodes with a wash buffer. Finally, and perhaps most significantly, the assay is quantitative and has a detection limit for NT-proBNP in the high picomolar range when the necessary reagents are stored on the device in a dry form.
Collapse
Affiliation(s)
- Nikhil Raj
- Department of Chemistry, The University of Texas at Austin, 105 E. 24th Street, Stop A5300, Austin, Texas 78712-1224, USA.
| | - Richard M Crooks
- Department of Chemistry, The University of Texas at Austin, 105 E. 24th Street, Stop A5300, Austin, Texas 78712-1224, USA.
| |
Collapse
|
8
|
Pan R, Li G, Liu S, Zhang X, Liu J, Su Z, Wu Y. Emerging nanolabels-based immunoassays: Principle and applications in food safety. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116462] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
9
|
Zhu X, Mohsin A, Zaman WQ, Liu Z, Wang Z, Yu Z, Tian X, Zhuang Y, Guo M, Chu J. Development of a novel noninvasive quantitative method to monitor Siraitia grosvenorii cell growth and browning degree using an integrated computer-aided vision technology and machine learning. Biotechnol Bioeng 2021; 118:4092-4104. [PMID: 34255354 DOI: 10.1002/bit.27886] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 06/19/2021] [Accepted: 07/07/2021] [Indexed: 12/28/2022]
Abstract
The rapid, accurate and noninvasive detection of biomass and plant cell browning can provide timely feedback on cell growth in plant cell culture. In this study, Siraitia grosvenorii suspension cells were taken as an example, a phenotype analysis platform was successfully developed to predict the biomass and the degree of cell browning based on the color changes of cells in computer-aided vision technology. First, a self-made laboratory system was established to obtain images. Then, matrices were prepared from digital images by a self-developed high-throughput image processing tool. Finally, classification models were used to judge different cell types, and then a semi-supervised classification to predict different degrees of cell browning. Meanwhile, regression models were developed to predict the plant cell mass. All models were verified with a good agreement by biological experiments. Therefore, this method can be applied for low-cost biomass estimation and browning degree quantification in plant cell culture.
Collapse
Affiliation(s)
- Xiaofeng Zhu
- State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai, China.,School of Biotechnology, East China University of Science and Technology, Shanghai, China
| | - Ali Mohsin
- State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai, China.,School of Biotechnology, East China University of Science and Technology, Shanghai, China
| | - Waqas Qamar Zaman
- Institute of Environmental Sciences and Engineering, School of Civil and Environmental Engineering, National University of Sciences and Technology (NUST), Islamabad, Pakistan
| | - Zebo Liu
- State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai, China.,School of Biotechnology, East China University of Science and Technology, Shanghai, China
| | - Zejian Wang
- State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai, China.,School of Biotechnology, East China University of Science and Technology, Shanghai, China
| | - Zhihong Yu
- School of Art Design and Media, East China University of Science and Technology, Shanghai, China
| | - Xiwei Tian
- State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai, China.,School of Biotechnology, East China University of Science and Technology, Shanghai, China
| | - Yingping Zhuang
- State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai, China.,School of Biotechnology, East China University of Science and Technology, Shanghai, China
| | - Meijin Guo
- State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai, China.,School of Biotechnology, East China University of Science and Technology, Shanghai, China
| | - Ju Chu
- State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai, China.,School of Biotechnology, East China University of Science and Technology, Shanghai, China
| |
Collapse
|
10
|
Pollok NE, Peng Y, Rabin C, Richards I, Crooks RM. Effect of Serum on Electrochemical Detection of Bioassays Having Ag Nanoparticle Labels. ACS Sens 2021; 6:1956-1962. [PMID: 33885282 PMCID: PMC8164997 DOI: 10.1021/acssensors.1c00446] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
The effect of serum on electrochemical detection of bioassays having silver nanoparticle (AgNP) detection labels was investigated. Both a model assay and an antigen-specific sandwich bioassay for the heart failure marker NT-proBNP were examined. In both cases, the AgNP labels were conjugated to a detection antibody. Electrochemical detection was carried out using a galvanic exchange/anodic stripping voltammetry method in which Au3+ exchanges with AgNP labels. The assays were carried out using a paper-based electrode platform. The bioassays were exposed to different serum conditions prior to and during detection. There are three important outcomes reported in this article. First, both the model- and antigen-specific assays could be formed in undiluted serum with no detectable interferences from the serum components. Second, to achieve the maximum possible electrochemical signal, the highest percentage of serum that can remain in an assay buffer during electrochemical detection is 0.25% when no washing is performed. The assay results are rendered inaccurate when 0.50% or more of serum is present. Third, the factors inhibiting galvanic exchange in serum probably relate to surface adsorption of biomolecules onto the AgNP labels, chelation of Au3+ by serum components, or both. The results reported here provide general guidance for using metal NP labels for electrochemical assays in biofluids.
Collapse
Affiliation(s)
- Nicole E. Pollok
- Department of Chemistry, The University of Texas at Austin, 100 E. 24th St., Stop A1590, Austin, Texas, 78712-1224, USA
| | - Yi Peng
- Department of Chemistry, The University of Texas at Austin, 100 E. 24th St., Stop A1590, Austin, Texas, 78712-1224, USA
| | - Charlie Rabin
- Department of Chemistry, The University of Texas at Austin, 100 E. 24th St., Stop A1590, Austin, Texas, 78712-1224, USA
| | - Ian Richards
- Interactives Executive Excellence LLC, Austin, Texas, 78733, USA
| | - Richard M. Crooks
- Department of Chemistry, The University of Texas at Austin, 100 E. 24th St., Stop A1590, Austin, Texas, 78712-1224, USA
| |
Collapse
|
11
|
Qriouet Z, Cherrah Y, Sefrioui H, Qmichou Z. Monoclonal Antibodies Application in Lateral Flow Immunochromatographic Assays for Drugs of Abuse Detection. Molecules 2021; 26:1058. [PMID: 33670468 PMCID: PMC7922373 DOI: 10.3390/molecules26041058] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 02/01/2021] [Accepted: 02/03/2021] [Indexed: 11/23/2022] Open
Abstract
Lateral flow assays (lateral flow immunoassays and nucleic acid lateral flow assays) have experienced a great boom in a wide variety of early diagnostic and screening applications. As opposed to conventional examinations (High Performance Liquid Chromatography, Polymerase Chain Reaction, Gas chromatography-Mass Spectrometry, etc.), they obtain the results of a sample's analysis within a short period. In resource-limited areas, these tests must be simple, reliable, and inexpensive. In this review, we outline the production process of antibodies against drugs of abuse (such as heroin, amphetamine, benzodiazepines, cannabis, etc.), used in lateral flow immunoassays as revelation or detection molecules, with a focus on the components, the principles, the formats, and the mechanisms of reaction of these assays. Further, we report the monoclonal antibody advantages over the polyclonal ones used against drugs of abuse. The perspective on aptamer use for lateral flow assay development was also discussed as a possible alternative to antibodies in view of improving the limit of detection, sensitivity, and specificity of lateral flow assays.
Collapse
Affiliation(s)
- Zidane Qriouet
- Medical Biotechnology Center, Moroccan Foundation for Advanced Science, Innovation & Research (MAScIR), Rabat 10100, Morocco; (Z.Q.); (H.S.)
- Laboratoire de Pharmacologie et Toxicologie, Faculté de Médecine et de Pharmacie, Université Mohammed V-Souissi, Rabat 10100, Morocco;
| | - Yahia Cherrah
- Laboratoire de Pharmacologie et Toxicologie, Faculté de Médecine et de Pharmacie, Université Mohammed V-Souissi, Rabat 10100, Morocco;
| | - Hassan Sefrioui
- Medical Biotechnology Center, Moroccan Foundation for Advanced Science, Innovation & Research (MAScIR), Rabat 10100, Morocco; (Z.Q.); (H.S.)
| | - Zineb Qmichou
- Medical Biotechnology Center, Moroccan Foundation for Advanced Science, Innovation & Research (MAScIR), Rabat 10100, Morocco; (Z.Q.); (H.S.)
| |
Collapse
|
12
|
Ahmed SR, Chand R, Kumar S, Mittal N, Srinivasan S, Rajabzadeh AR. Recent biosensing advances in the rapid detection of illicit drugs. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.116006] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
13
|
Zheng Q, Wu H, Jiang H, Yang J, Gao Y. Development of a Smartphone-Based Fluorescent Immunochromatographic Assay Strip Reader. SENSORS 2020; 20:s20164521. [PMID: 32823493 PMCID: PMC7471973 DOI: 10.3390/s20164521] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/03/2020] [Accepted: 08/11/2020] [Indexed: 01/29/2023]
Abstract
Fluorescence immunochromatographic assay (FICA) is a rapid immunoassay technique that has the characteristics of high precision and sensitivity. Although image FICA strip readers have the advantages of high portability and easy operation, the use of high-precision complementary metal oxide semiconductor (CMOS) image sensors leads to an increase in overall cost. Considering the popularity of CMOS image sensors in smartphones and their powerful processing functions, this work developed a smartphone-based FICA strip reader. An optical module suitable for the test strips with different fluorescent markers was designed by replacing the excitation light source and the light filter. An android smartphone was used for image acquisition and image denoising. Then, the test and control lines of the test strip image were recognized by the sliding window algorithm. Finally, the characteristic value of the strip image was calculated. A linear detection range from 10 to 5000 mIU/mL (R2 = 0.95) was obtained for human chorionic gonadotrophin with the maximum relative error less than 9.41%, and a linear detection range from 5 to 4000 pg/mL (R2 = 0.99) was obtained for aflatoxin B1, with the maximum relative error less than 12.71%. Therefore, the smartphone-based FICA strip reader had high portability, versatility, and accuracy.
Collapse
Affiliation(s)
- Qi Zheng
- Zhicheng College, Fuzhou University, Fuzhou 350002, China;
- Key Lab of Medical Instrumentation & Pharmaceutical Technology of Fujian Province, Fuzhou 350108, China; (H.W.); (H.J.); (J.Y.)
| | - Huihuang Wu
- Key Lab of Medical Instrumentation & Pharmaceutical Technology of Fujian Province, Fuzhou 350108, China; (H.W.); (H.J.); (J.Y.)
- College of Physics and Information Engineering, Fuzhou University, Fuzhou 350108, China
| | - Haiyan Jiang
- Key Lab of Medical Instrumentation & Pharmaceutical Technology of Fujian Province, Fuzhou 350108, China; (H.W.); (H.J.); (J.Y.)
| | - Jiejie Yang
- Key Lab of Medical Instrumentation & Pharmaceutical Technology of Fujian Province, Fuzhou 350108, China; (H.W.); (H.J.); (J.Y.)
- College of Physics and Information Engineering, Fuzhou University, Fuzhou 350108, China
| | - Yueming Gao
- Key Lab of Medical Instrumentation & Pharmaceutical Technology of Fujian Province, Fuzhou 350108, China; (H.W.); (H.J.); (J.Y.)
- College of Physics and Information Engineering, Fuzhou University, Fuzhou 350108, China
- Correspondence: ; Tel.: +86-1359-906-7568
| |
Collapse
|
14
|
Moyano A, Serrano-Pertierra E, Salvador M, Martínez-García JC, Piñeiro Y, Yañez-Vilar S, Gónzalez-Gómez M, Rivas J, Rivas M, Blanco-López MC. Carbon-Coated Superparamagnetic Nanoflowers for Biosensors Based on Lateral Flow Immunoassays. BIOSENSORS 2020; 10:E80. [PMID: 32707868 PMCID: PMC7460469 DOI: 10.3390/bios10080080] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Revised: 07/09/2020] [Accepted: 07/18/2020] [Indexed: 12/11/2022]
Abstract
Superparamagnetic iron oxide nanoflowers coated by a black carbon layer (Fe3O4@C) were studied as labels in lateral flow immunoassays. They were synthesized by a one-pot solvothermal route, and they were characterized (size, morphology, chemical composition, and magnetic properties). They consist of several superparamagnetic cores embedded in a carbon coating holding carboxylic groups adequate for bioconjugation. Their multi-core structure is especially efficient for magnetic separation while keeping suitable magnetic properties and appropriate size for immunoassay reporters. Their functionality was tested with a model system based on the biotin-neutravidin interaction. For this, the nanoparticles were conjugated to neutravidin using the carbodiimide chemistry, and the lateral flow immunoassay was carried out with a biotin test line. Quantification was achieved with both an inductive magnetic sensor and a reflectance reader. In order to further investigate the quantifying capacity of the Fe3O4@C nanoflowers, the magnetic lateral flow immunoassay was tested as a detection system for extracellular vesicles (EVs), a novel source of biomarkers with interest for liquid biopsy. A clear correlation between the extracellular vesicle concentration and the signal proved the potential of the nanoflowers as quantifying labels. The limit of detection in a rapid test for EVs was lower than the values reported before for other magnetic nanoparticle labels in the working range 0-3 × 107 EVs/μL. The method showed a reproducibility (RSD) of 3% (n = 3). The lateral flow immunoassay (LFIA) rapid test developed in this work yielded to satisfactory results for EVs quantification by using a precipitation kit and also directly in plasma samples. Besides, these Fe3O4@C nanoparticles are easy to concentrate by means of a magnet, and this feature makes them promising candidates to further reduce the limit of detection.
Collapse
Affiliation(s)
- Amanda Moyano
- Department of Physical and Analytical Chemistry & Institute of Biotechnology of Asturias, University of Oviedo, c/Julián Clavería 8, 33006 Oviedo, Spain; (A.M.); (E.S.-P.)
| | - Esther Serrano-Pertierra
- Department of Physical and Analytical Chemistry & Institute of Biotechnology of Asturias, University of Oviedo, c/Julián Clavería 8, 33006 Oviedo, Spain; (A.M.); (E.S.-P.)
| | - María Salvador
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33204 Gijón, Spain; (M.S.); (J.C.M.-G.); (M.R.)
| | - José Carlos Martínez-García
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33204 Gijón, Spain; (M.S.); (J.C.M.-G.); (M.R.)
| | - Yolanda Piñeiro
- Department of Applied Physics, University of Santiago de Compostela, Campus Vida, 15782 Santiago de Compostela, Spain; (Y.P.); (S.Y.-V.); (M.G.-G.); (J.R.)
| | - Susana Yañez-Vilar
- Department of Applied Physics, University of Santiago de Compostela, Campus Vida, 15782 Santiago de Compostela, Spain; (Y.P.); (S.Y.-V.); (M.G.-G.); (J.R.)
| | - Manuel Gónzalez-Gómez
- Department of Applied Physics, University of Santiago de Compostela, Campus Vida, 15782 Santiago de Compostela, Spain; (Y.P.); (S.Y.-V.); (M.G.-G.); (J.R.)
| | - José Rivas
- Department of Applied Physics, University of Santiago de Compostela, Campus Vida, 15782 Santiago de Compostela, Spain; (Y.P.); (S.Y.-V.); (M.G.-G.); (J.R.)
| | - Montserrat Rivas
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33204 Gijón, Spain; (M.S.); (J.C.M.-G.); (M.R.)
| | - M. Carmen Blanco-López
- Department of Physical and Analytical Chemistry & Institute of Biotechnology of Asturias, University of Oviedo, c/Julián Clavería 8, 33006 Oviedo, Spain; (A.M.); (E.S.-P.)
| |
Collapse
|
15
|
Moyano A, Serrano-Pertierra E, Salvador M, Martínez-García JC, Rivas M, Blanco-López MC. Magnetic Lateral Flow Immunoassays. Diagnostics (Basel) 2020; 10:E288. [PMID: 32397264 PMCID: PMC7278001 DOI: 10.3390/diagnostics10050288] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 05/05/2020] [Accepted: 05/06/2020] [Indexed: 12/13/2022] Open
Abstract
A new generation of magnetic lateral flow immunoassays is emerging as powerful tool for diagnostics. They rely on the use of magnetic nanoparticles (MNP) as detecting label, replacing conventional gold or latex beads. MNPs can be sensed and quantified by means of external devices, allowing the development of immunochromatographic tests with a quantitative capability. Moreover, they have an added advantage because they can be used for immunomagnetic separation (IMS), with improvements in selectivity and sensitivity. In this paper, we have reviewed the current knowledge on magnetic-lateral flow immunoassay (LFIA), coupled with both research and commercially available instruments. The work in the literature has been classified in two categories: optical and magnetic sensing. We have analysed the type of magnetic nanoparticles used in each case, their size, coating, crystal structure and the functional groups for their conjugation with biomolecules. We have also taken into account the analytical characteristics and the type of transduction. Magnetic LFIA have been used for the determination of biomarkers, pathogens, toxins, allergens and drugs. Nanocomposites have been developed as alternative to MNP with the purpose of sensitivity enhancement. Moreover, IMS in combination with other detection principles could also improve sensitivity and limit of detection. The critical analysis in this review could have an impact for the future development of magnetic LFIA in fields requiring both rapid separation and quantification.
Collapse
Affiliation(s)
- Amanda Moyano
- Department of Physical and Analytical Chemistry & Institute of Biotechnology of Asturias, University of Oviedo, c/ Julián Clavería 8, 33006 Oviedo, Spain; (A.M.); (E.S.-P.)
| | - Esther Serrano-Pertierra
- Department of Physical and Analytical Chemistry & Institute of Biotechnology of Asturias, University of Oviedo, c/ Julián Clavería 8, 33006 Oviedo, Spain; (A.M.); (E.S.-P.)
| | - María Salvador
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33204 Gijón, Spain; (M.S.); (J.C.M.-G.); (M.R.)
| | - José Carlos Martínez-García
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33204 Gijón, Spain; (M.S.); (J.C.M.-G.); (M.R.)
| | - Montserrat Rivas
- Department of Physics & IUTA, University of Oviedo, Campus de Viesques, 33204 Gijón, Spain; (M.S.); (J.C.M.-G.); (M.R.)
| | - M. Carmen Blanco-López
- Department of Physical and Analytical Chemistry & Institute of Biotechnology of Asturias, University of Oviedo, c/ Julián Clavería 8, 33006 Oviedo, Spain; (A.M.); (E.S.-P.)
| |
Collapse
|
16
|
Walgama C, Nguyen MP, Boatner LM, Richards I, Crooks RM. Hybrid paper and 3D-printed microfluidic device for electrochemical detection of Ag nanoparticle labels. LAB ON A CHIP 2020; 20:1648-1657. [PMID: 32255136 PMCID: PMC7204514 DOI: 10.1039/d0lc00276c] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In the present article we report a new hybrid microfluidic device (hyFlow) comprising a disposable paper electrode and a three-dimensional (3D) printed plastic chip for the electrochemical detection of a magnetic bead-silver nanoparticle (MB-AgNP) bioconjugate. This hybrid device evolved due to the difficulty of incorporating micron-scale MBs into paper-only fluidic devices. Specifically, paper fluidic devices can entrap MB-containing conjugates within their cellulose or nitrocellulose fiber matrix. The hyFlow system was designed to minimize such issues and transport MB conjugates more efficiently to the electrochemical detection zone of the device. The hyFlow system retains the benefit of fluid transport by pressure-driven flow, however, no pump is required for its operation. The hyFlow device is capable of detecting either pre-formed MB-AgNP conjugates or conjugates formed in situ. The detection limit of AgNPs using this device is 12 pM, which represents just 22 AgNPs per MB.
Collapse
Affiliation(s)
- Charuksha Walgama
- Department of Chemistry and Texas Materials Institute, The University of Texas at Austin, 100 East 24th Street, Stop A1590, Austin, Texas 78712-1224, USA.
| | - Michael P Nguyen
- Department of Chemistry and Texas Materials Institute, The University of Texas at Austin, 100 East 24th Street, Stop A1590, Austin, Texas 78712-1224, USA.
| | - Lisa M Boatner
- Department of Chemistry and Texas Materials Institute, The University of Texas at Austin, 100 East 24th Street, Stop A1590, Austin, Texas 78712-1224, USA.
| | - Ian Richards
- Interactives Executive Excellence LLC, Austin, Texas 78733, USA
| | - Richard M Crooks
- Department of Chemistry and Texas Materials Institute, The University of Texas at Austin, 100 East 24th Street, Stop A1590, Austin, Texas 78712-1224, USA.
| |
Collapse
|
17
|
Murzin D, Mapps DJ, Levada K, Belyaev V, Omelyanchik A, Panina L, Rodionova V. Ultrasensitive Magnetic Field Sensors for Biomedical Applications. SENSORS (BASEL, SWITZERLAND) 2020; 20:E1569. [PMID: 32168981 PMCID: PMC7146409 DOI: 10.3390/s20061569] [Citation(s) in RCA: 61] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 03/02/2020] [Accepted: 03/06/2020] [Indexed: 12/27/2022]
Abstract
The development of magnetic field sensors for biomedical applications primarily focuses on equivalent magnetic noise reduction or overall design improvement in order to make them smaller and cheaper while keeping the required values of a limit of detection. One of the cutting-edge topics today is the use of magnetic field sensors for applications such as magnetocardiography, magnetotomography, magnetomyography, magnetoneurography, or their application in point-of-care devices. This introductory review focuses on modern magnetic field sensors suitable for biomedicine applications from a physical point of view and provides an overview of recent studies in this field. Types of magnetic field sensors include direct current superconducting quantum interference devices, search coil, fluxgate, magnetoelectric, giant magneto-impedance, anisotropic/giant/tunneling magnetoresistance, optically pumped, cavity optomechanical, Hall effect, magnetoelastic, spin wave interferometry, and those based on the behavior of nitrogen-vacancy centers in the atomic lattice of diamond.
Collapse
Affiliation(s)
- Dmitry Murzin
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
| | - Desmond J. Mapps
- Faculty of Science and Engineering, University of Plymouth, Plymouth PL4 8AA, UK;
| | - Kateryna Levada
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
| | - Victor Belyaev
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
| | - Alexander Omelyanchik
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
| | - Larissa Panina
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
- National University of Science and Technology, MISiS, 119049 Moscow, Russia
| | - Valeria Rodionova
- Institute of Physics, Mathematics and Information Technology, Immanuel Kant Baltic Federal University, 236041 Kaliningrad, Russia; (K.L.); (V.B.); (A.O.); (L.P.); (V.R.)
| |
Collapse
|
18
|
Recent advances in high-sensitivity detection methods for paper-based lateral-flow assay. Biosens Bioelectron 2020; 152:112015. [PMID: 32056735 DOI: 10.1016/j.bios.2020.112015] [Citation(s) in RCA: 190] [Impact Index Per Article: 47.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 01/02/2020] [Accepted: 01/08/2020] [Indexed: 12/19/2022]
Abstract
Paper-based lateral-flow assays (LFAs) have achieved considerable commercial success and continue to have a significant impact on medical diagnostics and environmental monitoring. Conventional LFAs are typically performed by examining the color changes in the test bands by naked eye. However, for critical biochemical markers that are present in extremely small amounts in the clinical specimens, this readout method is not quantitative, and does not provide sufficient sensitivity or suitable detection limit for a reliable assay. Diverse technologies for high-sensitivity LFA detection have been developed and commercialization efforts are underway. In this review, we aim to provide a critical and objective overview of the recent progress in high-sensitivity LFA detection technologies, which involve the exploitation of the physical and chemical responses of transducing particles. The features and biomedical applications of the technologies, along with future prospects and challenges, are also discussed.
Collapse
|
19
|
Liu C, Wu S, Yan Y, Dong Y, Shen X, Huang C. Application of magnetic particles in forensic science. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115674] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
20
|
Celikbas E, Balaban S, Evran S, Coskunol H, Timur S. A Bottom-Up Approach for Developing Aptasensors for Abused Drugs: Biosensors in Forensics. BIOSENSORS 2019; 9:E118. [PMID: 31581533 PMCID: PMC6955935 DOI: 10.3390/bios9040118] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 09/27/2019] [Accepted: 09/30/2019] [Indexed: 02/07/2023]
Abstract
Aptamer-based point-of-care (POC) diagnostics platforms may be of substantial benefit in forensic analysis as they provide rapid, sensitive, user-friendly, and selective analysis tools for detection. Aptasensors have not yet been adapted commercially. However, the significance of the applications of aptasensors in the literature exceeded their potential. Herein, in this review, a bottom-up approach is followed to describe the aptasensor development and application procedure, starting from the synthesis of the corresponding aptamer sequence for the selected analyte to creating a smart surface for the sensitive detection of the molecule of interest. Optical and electrochemical biosensing platforms, which are designed with aptamers as recognition molecules, detecting abused drugs are critically reviewed, and existing and possible applications of different designs are discussed. Several potential disciplines in which aptamer-based biosensing technology can be of greatest value, including forensic drug analysis and biological evidence, are then highlighted to encourage researchers to focus on developing aptasensors in these specific areas.
Collapse
Affiliation(s)
- Eda Celikbas
- Department of Biochemistry, Institute of Natural and Applied Sciences, Ege University, 35100 Bornova, Izmir, Turkey;
| | - Simge Balaban
- Department of Biochemistry, Institute of Natural and Applied Sciences, Ege University, 35100 Bornova, Izmir, Turkey;
| | - Serap Evran
- Department of Biochemistry, Institute of Natural and Applied Sciences, Ege University, 35100 Bornova, Izmir, Turkey;
- Department of Biochemistry, Faculty of Science, Ege University, 35100 Bornova, Izmir, Turkey
| | - Hakan Coskunol
- Department of Mental Health and Diseases, Faculty of Medicine, Ege University, 35100 Bornova, Izmir, Turkey;
| | - Suna Timur
- Department of Biochemistry, Institute of Natural and Applied Sciences, Ege University, 35100 Bornova, Izmir, Turkey;
- Department of Biochemistry, Faculty of Science, Ege University, 35100 Bornova, Izmir, Turkey
- Central Research Testing and Analysis Laboratory Research and Application Center, Ege University, 35100 Bornova, Izmir, Turkey
| |
Collapse
|
21
|
Tran TV, Nguyen BV, Nguyen TTP, Tran TT, Pham KG, Le QB, Do BN, Pham HN, Nguyen CV, Dinh DPH, Ha VT, Doan THT, Le HQ. Development of a highly sensitive magneto-enzyme lateral flow immunoassay for dengue NS1 detection. PeerJ 2019; 7:e7779. [PMID: 31579630 PMCID: PMC6765353 DOI: 10.7717/peerj.7779] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Accepted: 08/28/2019] [Indexed: 01/11/2023] Open
Abstract
Background Dengue infection represents a global health issue of growing importance. Dengue non-structural protein 1 (NS1) plays a central role in the early detection of the disease. The most common method for NS1 detection is testing by lateral flow immunoassays (LFIAs) with varying sensitivity. In this study, we present a highly sensitive magneto-enzyme LFIA for prompt diagnosis of dengue. Methods We have demonstrated the development of a magneto-enzyme LFIA combining super-paramagnetic nanoparticles as labels and Biotin–Streptavidin signal amplification strategy to detect dengue NS1. Factors affecting the test performance including antibody pair, super-paramagnetic nanoparticle size, nitrocellulose membrane type, amounts of detection and capture antibodies, and amounts of Streptavidin-polyHRP were optimized. Analytical sensitivity and cross-reactivity were determined. Clinical performance of the novel assay was evaluated using a panel of 120 clinical sera. Results This newly developed assay could detect NS1 of all four serotypes of dengue virus (DENV). The limit of detection (LOD) was found to be as low as 0.25 ng ml−1 for DENV-1 and DENV-3, 0.1 ng ml−1 for DENV-2, and 1.0 ng ml−1 for DENV-4. The LOD for DENV-2 was a 50-fold improvement over the best values previously reported. There was an absence of cross-reactivity with Zika NS1, Hepatitis B virus, Hepatitis C virus, and Japanese encephalitis virus. The sensitivity and specificity of the novel assay were 100% when tested on clinical samples. Conclusions We have successfully developed a magneto-enzyme LFIA, allowing rapid and highly sensitive detection of dengue NS1, which is essential for proper management of patients infected with DENV.
Collapse
Affiliation(s)
| | | | - Thao T P Nguyen
- School of Biotechnology and Food Technology, Hanoi University of Science and Technology, Hanoi, Vietnam
| | - Tung T Tran
- School of Biotechnology and Food Technology, Hanoi University of Science and Technology, Hanoi, Vietnam
| | | | - Quang B Le
- Military Medical University, Hanoi, Vietnam
| | - Binh N Do
- Military Medical University, Hanoi, Vietnam
| | | | | | - Duong P H Dinh
- Nguyen Hue High School for Gifted Students, Hanoi, Vietnam
| | - Van T Ha
- Hanoi-Amsterdam High School for Gifted Students, Hanoi, Vietnam
| | - Trang H T Doan
- School of Biotechnology and Food Technology, Hanoi University of Science and Technology, Hanoi, Vietnam
| | - Hoa Q Le
- School of Biotechnology and Food Technology, Hanoi University of Science and Technology, Hanoi, Vietnam
| |
Collapse
|
22
|
Huang Z, Hu S, Xiong Y, Wei H, Xu H, Duan H, Lai W. Application and development of superparamagnetic nanoparticles in sample pretreatment and immunochromatographic assay. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.03.004] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
23
|
Guo L, Shao Y, Duan H, Ma W, Leng Y, Huang X, Xiong Y. Magnetic Quantum Dot Nanobead-Based Fluorescent Immunochromatographic Assay for the Highly Sensitive Detection of Aflatoxin B 1 in Dark Soy Sauce. Anal Chem 2019; 91:4727-4734. [PMID: 30840438 DOI: 10.1021/acs.analchem.9b00223] [Citation(s) in RCA: 86] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Herein, we synthesized bifunctional magnetic fluorescent beads (MFBs) with a distinct core/shell structure by encapsulating octadecylamine-coated CdSe/ZnS QDs (OC-QDs) and oleic acid-modified iron oxide nanoparticles (OA-IONPs) into two polymer matrixes with different hydrophobic properties. The OC-QDs and OA-IONPs were mainly distributed in the outer layer of MFBs. The resultant MFBs displayed ca. 226-fold stronger fluorescence emission relative to the corresponding OC-QDs and retained ca. 45.4% of the saturation magnetization of the OA-IONPs. The MFBs were used to purify and enrich aflatoxin B1 (AFB1) from dark soy sauce and then utilized as a fluorescent reporter of immunochromatographic assay (ICA) for the sensitive detection of AFB1. Under the optimal detection conditions, the MFB-based ICA (MFB-ICA) displayed a dynamic linear detection of AFB1 in sauce extract over the range of 5-150 pg/mL with a half maximal inhibitory concentration of 27 ± 3 pg/mL ( n = 3). The detection limits for AFB1 in sauce extract and real dark soy sauce were 3 and 51 pg/mL, respectively, which are considerably better than those of the previously reported fluorescent bead-based ICA methods. The analytical performance of the proposed MFB-ICA in terms of selectivity and accuracy was investigated by analyzing AFB1-spiked dark soy sauce samples. The reliability of the proposed method was further confirmed by ultraperformance liquid chromatography with fluorescence detection. With the combined advantages of QDs and IONPs, the resultant MFBs offer great potential as reporters of ICA for the sensitive detection of trace pollutants in complex matrix samples.
Collapse
Affiliation(s)
- Liang Guo
- State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China
- Jiangxi-OAI Joint Research Institute , Nanchang University , Nanchang 330047 , P. R. China
| | - Yanna Shao
- State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China
| | - Hong Duan
- State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China
- Jiangxi-OAI Joint Research Institute , Nanchang University , Nanchang 330047 , P. R. China
| | - Wei Ma
- State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China
- Gaoping Center for Comprehensive Inspection and Testing , Gaoping 048411 , P. R. China
| | - Yuankui Leng
- State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China
| | - Xiaolin Huang
- State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China
| | - Yonghua Xiong
- State Key Laboratory of Food Science and Technology , Nanchang University , Nanchang 330047 , P. R. China
- Jiangxi-OAI Joint Research Institute , Nanchang University , Nanchang 330047 , P. R. China
| |
Collapse
|