1
|
Atabakhsh S, Haji Abbasali H, Jafarabadi Ashtiani S. Thermally programmable time delay switches for multi-step assays in paper-based microfluidics. Talanta 2024; 271:125695. [PMID: 38295445 DOI: 10.1016/j.talanta.2024.125695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 12/18/2023] [Accepted: 01/17/2024] [Indexed: 02/02/2024]
Abstract
Paper-based microfluidic devices offer advantages such as low cost and disposability for point-of-care diagnostic applications. However, actuation of fluids on paper can be a challenge in multi-step and complex assays. In this work, a thermally programmable time-delay switch (TPTDS) is presented which operates by causing delays in the fluid path of a microfluidics paper-based analytical device (μPAD) by utilizing screen-printed wax micro-bridges. The time-delay is achieved through an electrical power feedback loop which indirectly adjusts the temperature of each individual micro-bridge, melting the wax into the paper. The melted wax manipulates the fluid flow depending on its penetration depth into the paper channel, which is a function of the applied temperature. To demonstrate functionality of the proposed method, the TPTDS is employed to automate and perform the nitrate assay which requires sequential delivery of reagents. Colorimetric detection is used to quantify the results by utilizing an electronic color sensor.
Collapse
Affiliation(s)
- Saeed Atabakhsh
- Department of Electrical Engineering, Roudehen Branch, Islamic Azad University, Roudehen, Iran
| | - Hossein Haji Abbasali
- School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, 14395/515, Iran
| | - Shahin Jafarabadi Ashtiani
- School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, 14395/515, Iran.
| |
Collapse
|
2
|
Li Z, Liu H, Wang D, Zhang M, Yang Y, Ren TL. Recent advances in microfluidic sensors for nutrients detection in water. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2022.116790] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
3
|
Lovecchio N, Costantini F, Nascetti A, de Cesare G, Caputo D. Thin-Film-Based Multifunctional System for Optical Detection and Thermal Treatment of Biological Samples. BIOSENSORS 2022; 12:bios12110969. [PMID: 36354478 PMCID: PMC9688047 DOI: 10.3390/bios12110969] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/24/2022] [Accepted: 10/31/2022] [Indexed: 05/31/2023]
Abstract
In this work, we present a multifunctional Lab-on-Chip (LoC) platform based on hydrogenated amorphous silicon sensors suitable for a wide range of application in the fields of biochemical and food quality control analysis. The proposed system includes a LoC fabricated on a 5 cm × 5 cm glass substrate and a set of electronic boards for controlling the LoC functionalities. The presented Lab-on-Chip comprises light and temperature sensors, a thin film resistor acting as a heating source, and an optional thin film interferential filter suitable for fluorescence analysis. The developed electronics allows to control the thin film heater, a light source for fluorescence and absorption measurements, and the photosensors to acquire luminescent signals. All these modules are enclosed in a black metal box ensuring the portability of the whole platform. System performances have been evaluated in terms of sensor optical performances and thermal control achievements. For optical sensors, we have found a minimum number of detectable photons of 8 × 104 s-1·cm-2 at room temperature, 1.6 × 106 s-1·cm-2 in presence of fluorescence excitation source, and 2.4 × 106 s-1·cm-2 at 90 °C. From a thermal management point of view, we have obtained heating and cooling rates both equal to 2.2 °C/s, and a temperature sensor sensitivity of about 3 mV/°C even in presence of light. The achieved performances demonstrate the possibility to simultaneously use all integrated sensors and actuators, making promising the presented platform for a wide range of application fields.
Collapse
Affiliation(s)
- Nicola Lovecchio
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy
| | - Francesca Costantini
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy
- CREA-DC Research Centre for Plant Protection and Certification, 00156 Rome, Italy
| | - Augusto Nascetti
- School of Aerospace Engineering, Sapienza University of Rome, 00138 Rome, Italy
| | - Giampiero de Cesare
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy
| | - Domenico Caputo
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy
| |
Collapse
|
4
|
Doǧan V, Isık T, Kılıç V, Horzum N. A field-deployable water quality monitoring with machine learning-based smartphone colorimetry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3458-3466. [PMID: 36000587 DOI: 10.1039/d2ay00785a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Water quality monitoring is an increasing global concern as the pollution of water sources causes adverse effects on economic growth and human health. Traditional approaches to the detection of pollutants are time-consuming and labor-intensive due to the requirement of sophisticated equipment or laboratory settings. Therefore, portable devices featuring rapid response and easy operation are indispensable in water quality monitoring. Herein, smartphone-based colorimetric pollutant quantification is demonstrated in a machine learning (ML) framework. As a proof of concept, the presence of seven ions in water was analyzed using colorimetric strips. The color variation on the strip indicators was captured under eight lighting conditions with five smartphones, providing robustness against the illumination variation and camera optics for ML classifiers. Color and texture features were extracted from the images to train the classifiers. Among the twenty-three classifiers, K-Nearest Neighbors exhibits the best classification performance, leading to the integration with our custom-designed Android application called Hydro Sens. The proposed approach was also tested with real samples taken from local water sources. The results prove that incorporating color strips with ML with a smartphone application can be used for water quality monitoring, which offers promising alternatives for sophisticated equipment that is especially applicable in resource-limited settings.
Collapse
Affiliation(s)
- Vakkas Doǧan
- Department of Electrical and Electronics Engineering, Izmir Katip Celebi University, 35620 Turkey.
| | - Tuǧba Isık
- Department of Mineral Analysis and Technologies, General Directorate of Mineral Research and Exploration (MTA), Ankara, Turkey
| | - Volkan Kılıç
- Department of Electrical and Electronics Engineering, Izmir Katip Celebi University, 35620 Turkey.
| | - Nesrin Horzum
- Department of Engineering Sciences, Izmir Katip Celebi University, 35620 Izmir, Turkey
| |
Collapse
|
5
|
Catalan-Carrio R, Saez J, Fernández Cuadrado LÁ, Arana G, Basabe-Desmonts L, Benito-Lopez F. Ionogel-based hybrid polymer-paper handheld platform for nitrite and nitrate determination in water samples. Anal Chim Acta 2022; 1205:339753. [DOI: 10.1016/j.aca.2022.339753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 03/04/2022] [Accepted: 03/20/2022] [Indexed: 11/01/2022]
|
6
|
Catini A, Capuano R, Tancredi G, Dionisi G, Di Giuseppe D, Filippi J, Martinelli E, Di Natale C. A Lab-on-a-Chip Based Automatic Platform for Continuous Nitrites Sensing in Aquaculture. SENSORS 2022; 22:s22020444. [PMID: 35062404 PMCID: PMC8778806 DOI: 10.3390/s22020444] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 12/31/2021] [Accepted: 01/02/2022] [Indexed: 02/01/2023]
Abstract
In aquaculture, the density of fish stock, use of feeding, and surrounding environmental conditions can easily result in an excessive concentration of harmful compounds that require continuous monitoring. Chemical sensors are available for most of these compounds, however, operative conditions and continuous monitoring in water make the development of sensors suitable for long and unattended deployments difficult. A possible solution is the development of engineered automatic labs where the uptake of sample and the contact with water is reduced and the use of a minimal quantity of reagents enables the implementation of reliable chemical assays. In this paper, a platform for automatic chemical assays is presented. The concept is demonstrated with the detection of nitrites based on the well-known colorimetric Griess reaction. The platform is centered around a lab-on-a-chip where reagents and water samples are mixed. The color of the reaction product is measured with low-cost optoelectronic components. Results show the feasibility of the approach with a minimum detectable concentration of about 0.1 mg/L which is below the tolerance level for aquaculture farms.
Collapse
|
7
|
Saez J, Catalan-Carrio R, Owens RM, Basabe-Desmonts L, Benito-Lopez F. Microfluidics and materials for smart water monitoring: A review. Anal Chim Acta 2021; 1186:338392. [PMID: 34756264 DOI: 10.1016/j.aca.2021.338392] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 03/02/2021] [Accepted: 03/02/2021] [Indexed: 01/03/2023]
Abstract
Water quality monitoring of drinking, waste, fresh and seawaters is of great importance to ensure safety and wellbeing for humans, fauna and flora. Researchers are developing robust water monitoring microfluidic devices but, the delivery of a cost-effective, commercially available platform has not yet been achieved. Conventional water monitoring is mainly based on laboratory instruments or sophisticated and expensive handheld probes for on-site analysis, both requiring trained personnel and being time-consuming. As an alternative, microfluidics has emerged as a powerful tool with the capacity to replace conventional analytical systems. Nevertheless, microfluidic devices largely use conventional pumps and valves for operation and electronics for sensing, that increment the dimensions and cost of the final platforms, reducing their commercialization perspectives. In this review, we critically analyze the characteristics of conventional microfluidic devices for water monitoring, focusing on different water sources (drinking, waste, fresh and seawaters), and their application in commercial products. Moreover, we introduce the revolutionary concept of using functional materials such as hydrogels, poly(ionic liquid) hydrogels and ionogels as alternatives to conventional fluidic handling and sensing tools, for water monitoring in microfluidic devices.
Collapse
Affiliation(s)
- Janire Saez
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC), Group, Analytical Chemistry, University of the Basque Country UPV/EHU, Spain; Bioelectronic Systems Technology Group, Department of Chemical Engineering and Biotechnology, Philippa Fawcett Drive, Cambridge, CB3 0AS, UK.
| | - Raquel Catalan-Carrio
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC), Group, Analytical Chemistry, University of the Basque Country UPV/EHU, Spain; Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain
| | - Róisín M Owens
- Bioelectronic Systems Technology Group, Department of Chemical Engineering and Biotechnology, Philippa Fawcett Drive, Cambridge, CB3 0AS, UK
| | - Lourdes Basabe-Desmonts
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Vitoria-Gasteiz, Spain; Basque Foundation for Science, IKERBASQUE, Spain; Bioaraba Health Research Institute, Microfluidics Cluster UPV/EHU, Vitoria-Gasteiz, Spain; BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940, Leioa, Spain.
| | - Fernando Benito-Lopez
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC), Group, Analytical Chemistry, University of the Basque Country UPV/EHU, Spain; Bioaraba Health Research Institute, Microfluidics Cluster UPV/EHU, Vitoria-Gasteiz, Spain; BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940, Leioa, Spain.
| |
Collapse
|
8
|
Morsy MK, Morsy OM, Abd-Elaaty EM, Elsabagh R. Development and Validation of Rapid Colorimetric Detection of Nitrite Concentration in Meat Products on a Polydimethylsiloxane (PDMS) Microfluidic Device. FOOD ANAL METHOD 2021. [DOI: 10.1007/s12161-021-02139-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
9
|
De Beer DJ, Joubert TH. Validation of Low-Cost Impedance Analyzer via Nitrate Detection. SENSORS (BASEL, SWITZERLAND) 2021; 21:6695. [PMID: 34641015 PMCID: PMC8512716 DOI: 10.3390/s21196695] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 09/10/2021] [Accepted: 09/15/2021] [Indexed: 01/02/2023]
Abstract
Impedance spectroscopy is a widely used electrochemical technique with a wide variety of applications. Many of these applications benefit from the additional accessibility provided by low-cost impedance devices. With this in mind, a low-cost impedance device was designed for a high performance-to-cost ratio. The performance of this analyzer was validated against a high-performance DropSens µStat-i 400s potentiostat by performing an application-based experiment. Nitrate detection provides a relevant experiment because of the importance of maintaining precise nitrate concentrations to mitigate the impact of nitrate fluctuations on the environment. Dissolved nitrate samples of different concentrations, in the range 3-1000 mg/L, were confirmed colorimetrically and measured with both instruments. A calibration curve of the real impedance matched a sigmoidal transfer, with a linear region for concentrations below 10 mg/L. The device under investigation exhibited an average magnitude error of 1.28% and an average phase error of 0.96∘ relative to the high-performance standard, which validates the performance of the low-cost device. A cost analysis is presented that highlights some of the complexities of cost comparisons.
Collapse
Affiliation(s)
- Dirk Johannes De Beer
- Carl and Emily Fuchs Institute for Microelectronics (CEFIM), University of Pretoria, Pretoria 0002, South Africa;
| | | |
Collapse
|
10
|
Simultaneous Absorbance and Fluorescence Measurements Using an Inlaid Microfluidic Approach. SENSORS 2021; 21:s21186250. [PMID: 34577456 PMCID: PMC8473408 DOI: 10.3390/s21186250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 09/14/2021] [Accepted: 09/15/2021] [Indexed: 11/17/2022]
Abstract
A novel microfluidic optical cell is presented that enables simultaneous measurement of both light absorbance and fluorescence on microlitre volumes of fluid. The chip design is based on an inlaid fabrication technique using clear and opaque poly(methyl methacrylate) or PMMA to create a 20.2 mm long optical cell. The inlaid approach allows fluid interrogation with minimal interference from external light over centimeter long path lengths. The performance of the optical cell is evaluated using a stable fluorescent dye: rhodamine B. Excellent linear relationships (R2 > 0.99) are found for both absorbance and fluorescence over a 0.1-10 µM concentration range. Furthermore, the molar attenuation spectrum is accurately measured over the range 460-550 nm. The approach presented here is applicable to numerous colorimetric- or fluorescence-based assays and presents an important step in the development of multipurpose lab-on-chip sensors.
Collapse
|
11
|
Devamoglu U, Duman I, Saygili E, Yesil-Celiktas O. Development of an Integrated Optical Sensor for Determination of β-Hydroxybutyrate Within the Microplatform. Appl Biochem Biotechnol 2021; 193:2759-2768. [PMID: 33834362 DOI: 10.1007/s12010-021-03563-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Accepted: 03/22/2021] [Indexed: 11/26/2022]
Abstract
Ketone bodies (acetoacetate, beta-hydroxybutyrate (βHB), acetone) are generated as a result of fatty acid oxidation in the liver and exist at low concentrations in urine and blood. Elevated concentrations can indicate health problems such as diabetes, childhood hypoglycemia, alcohol, or salicylate poisoning. Development of portable and cost-effective bedside point-of-care (POC) tests to detect such compounds can help to reduce the risk of disease progression. In this study, βHB was chosen as a model molecule for developing an optical sensor-integrated microplatform. Prior to sensor optimization, βHB levels were measured at a concentration range of 0.02 and 0.1 mM spectrophotometrically, which is far below the reported elevated ranges of 1-2 mM and resulting absorbance changes were converted into an Arduino microcontroller code for the correlation. Measurements performed with the designed integrated microplatform were found significant. Integrated microplatform was verified with the benchtop spectrophotometer. Measurements between 0.02 and 0.1 mM substrate concentration were found highly sensitive with "y = 0.7347x + 0.00184" with R2 value of 0.9796, and the limit of detection was determined as 0.02 mM. Based on these results, the proposed system will allow on-site and early intervention.
Collapse
Affiliation(s)
- Utku Devamoglu
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100, Bornova, Izmir, Turkey
| | - Irem Duman
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100, Bornova, Izmir, Turkey
| | - Ecem Saygili
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100, Bornova, Izmir, Turkey
| | - Ozlem Yesil-Celiktas
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100, Bornova, Izmir, Turkey.
| |
Collapse
|
12
|
Recent Advancement of the Sensors for Monitoring the Water Quality Parameters in Smart Fisheries Farming. COMPUTERS 2021. [DOI: 10.3390/computers10030026] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Water quality is the most critical factor affecting fish health and performance in aquaculture production systems. Fish life is mostly dependent on the water fishes live in for all their needs. Therefore, it is essential to have a clear understanding of the water quality requirements of the fish. This research discusses the critical water parameters (temperature, pH, nitrate, phosphate, calcium, magnesium, and dissolved oxygen (DO)) for fisheries and reviews the existing sensors to detect those parameters. Moreover, this paper proposes a prospective solution for smart fisheries that will help to monitor water quality factors, make decisions based on the collected data, and adapt more quickly to changing conditions.
Collapse
|
13
|
Shahnia S, Ebendorff-Heidepriem H, Evans D, Afshar S. A Fibre-Optic Platform for Sensing Nitrate Using Conducting Polymers. SENSORS (BASEL, SWITZERLAND) 2020; 21:E138. [PMID: 33379268 PMCID: PMC7794756 DOI: 10.3390/s21010138] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 12/24/2020] [Accepted: 12/24/2020] [Indexed: 11/16/2022]
Abstract
Monitoring nitrate ions is essential in agriculture, food industry, health sector and aquatic ecosystem. We show that a conducting polymer, poly(3,4-ethylenedioxythiophene) (PEDOT), can be used for nitrate sensing through a process in which nitrate ion uptake leads to oxidation of PEDOT and change of its optical properties. In this study, a new platform is developed in which a single-mode fibre coated at the tip with PEDOT is used for nitrate sensing. A crucial step towards this goal is introduction of carbonate exposure to chemically reduced PEDOT to a baseline value. The proposed platform exhibits the change in optical behaviour of the PEDOT layer at the tip of the fibre as it undergoes chemical oxidation and reduction (redox). The change in optical properties due to redox switching varies with the intensity of light back reflected by the fibre coated with PEDOT. The proposed platform during oxidation demonstrates linear response for the uptake of nitrate ions in concentrations ranging between 0.2 and 40 parts per million (ppm), with a regression coefficient R2=0.97 and a detection limit of 6.7 ppm. The procedure for redox switching is repeatable as the back reflection light intensity reaches ±1.5% of the initial value after reduction.
Collapse
Affiliation(s)
- Soroush Shahnia
- Laser Physics and Photonic Devices Laboratories, UniSA STEM, University of South Australia, Mawson Lakes, SA 5095, Australia;
| | - Heike Ebendorff-Heidepriem
- ARC Centre of Excellence for Nanoscale Biophotonics, Institute for Photonics and Advanced Sensing, The University of Adelaide, Adelaide, SA 5000, Australia;
| | - Drew Evans
- Future Industries Institute, University of South Australia, Mawson Lakes, SA 5095, Australia
| | - Shahraam Afshar
- Laser Physics and Photonic Devices Laboratories, UniSA STEM, University of South Australia, Mawson Lakes, SA 5095, Australia;
| |
Collapse
|
14
|
Charbaji A, Heidari-Bafroui H, Anagnostopoulos C, Faghri M. A New Paper-Based Microfluidic Device for Improved Detection of Nitrate in Water. SENSORS 2020; 21:s21010102. [PMID: 33375290 PMCID: PMC7794956 DOI: 10.3390/s21010102] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 12/06/2020] [Accepted: 12/23/2020] [Indexed: 12/11/2022]
Abstract
In this paper, we report a simple and inexpensive paper-based microfluidic device for detecting nitrate in water. This device incorporates two recent developments in paper-based technology suitable for nitrate detection and has an optimized microfluidic design. The first technical advancement employed is an innovative fibrous composite material made up of cotton fibers and zinc microparticles that can be incorporated in paper-based devices and results in better nitrate reduction. The second is a detection zone with an immobilized reagent that allows the passage of a larger sample volume. Different acids were tested—citric and phosphoric acids gave better results than hydrochloric acid since this acid evaporates completely without leaving any residue behind on paper. Different microfluidic designs that utilize various fluid control technologies were investigated and a design with a folding detection zone was chosen and optimized to improve the uniformity of the signal produced. The optimized design allowed the device to achieve a limit of detection and quantification of 0.53 ppm and 1.18 ppm, respectively, for nitrate in water. This accounted for more than a 40% improvement on what has been previously realized for the detection of nitrate in water using paper-based technology.
Collapse
|
15
|
Fan Y, Huang Y, Linthicum W, Liu F, Beringhs AO, Dang Y, Xu Z, Chang SY, Ling J, Huey BD, Suib SL, Ma AWK, Gao PX, Lu X, Lei Y, Shaw MT, Li B. Toward Long-Term Accurate and Continuous Monitoring of Nitrate in Wastewater Using Poly(tetrafluoroethylene) (PTFE)-Solid-State Ion-Selective Electrodes (S-ISEs). ACS Sens 2020; 5:3182-3193. [PMID: 32933249 DOI: 10.1021/acssensors.0c01422] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Long-term accurate and continuous monitoring of nitrate (NO3-) concentration in wastewater and groundwater is critical for determining treatment efficiency and tracking contaminant transport. Current nitrate monitoring technologies, including colorimetric, chromatographic, biometric, and electrochemical sensors, are not feasible for continuous monitoring. This study addressed this challenge by modifying NO3- solid-state ion-selective electrodes (S-ISEs) with poly(tetrafluoroethylene) (PTFE, (C2F4)n). The PTFE-loaded S-ISE membrane polymer matrix reduces water layer formation between the membrane and electrode/solid contact, while paradoxically, the even more hydrophobic PTFE-loaded S-ISE membrane prevents bacterial attachment despite the opposite approach of hydrophilic modifications in other antifouling sensor designs. Specifically, an optimal ratio of 5% PTFE in the S-ISE polymer matrix was determined by a series of characterization tests in real wastewater. Five percent of PTFE alleviated biofouling to the sensor surface by enhancing the negative charge (-4.5 to -45.8 mV) and lowering surface roughness (Ra: 0.56 ± 0.02 nm). It simultaneously mitigated water layer formation between the membrane and electrode by increasing hydrophobicity (contact angle: 104°) and membrane adhesion and thus minimized the reading (mV) drift in the baseline sensitivity ("data drifting"). Long-term accuracy and durability of 5% PTFE-loaded NO3- S-ISEs were well demonstrated in real wastewater over 20 days, an improvement over commercial sensor longevity.
Collapse
Affiliation(s)
- Yingzheng Fan
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Yuankai Huang
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Will Linthicum
- Department of Materials Science & Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Fangyuan Liu
- Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, United States
| | | | - Yanliu Dang
- Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Zhiheng Xu
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Shing-Yun Chang
- Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, United States
- Department of Chemical and Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Jing Ling
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Bryan D. Huey
- Department of Materials Science & Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Steven L. Suib
- Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Anson W. K. Ma
- Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, United States
- Department of Chemical and Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Pu-Xian Gao
- Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Xiuling Lu
- School of Pharmacy, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Yu Lei
- Department of Chemical and Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Montgomery T. Shaw
- Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Baikun Li
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| |
Collapse
|
16
|
Gold nanoparticles decorated bimetallic CuNi-based hollow nanoarchitecture for the enhancement of electrochemical sensing performance of nitrite. Mikrochim Acta 2020; 187:572. [PMID: 32940777 DOI: 10.1007/s00604-020-04545-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 09/02/2020] [Indexed: 01/24/2023]
Abstract
Gold nanoparticles (AuNPs) decorated bimetallic CuNi-based hollow nanoarchitecture (CNHN) are reported for the first time as a nonenzymatic sensor for the quantification of nitrite in neutral solution . The CNHN was prepared via a convenient calcining routine using the bimetallic CuNi-MOFs as a coprecursor. The unique chemical structure of hollow CNHN with high specific surface area and abundant terminal amino groups effectively avoid the aggregation of AuNPs and facilitate the subsequent adsorption of nitrite. The Au/CNHN exhibited high electrocatalytic activity towards nitrite oxidation due to the synergetic catalytic effect of AuNPs and CNHN. Chronoamperometric detection of nitrite at the Au/CNHN/GCE achieved a lower linear calibration range of 0.05 to 1.15 mM, with an LOD of 0.017 μM compared with previous reports. The proposed method obtained satisfactory recoveries for nitrite determination in practical applications, which was verified by UV-Vis spectrophotometry. The prepared sensor based on Au/CNHN featured favorable selectivity and stability, which provides a promising approach for real sample analysis. Graphical abstract.
Collapse
|
17
|
Al-Halhouli A, El Far B, Albagdady A, Al-Faqheri W. Development of Active Centrifugal Pump for Microfluidic CD Platforms. MICROMACHINES 2020; 11:E140. [PMID: 32012735 PMCID: PMC7074607 DOI: 10.3390/mi11020140] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Revised: 01/14/2020] [Accepted: 01/16/2020] [Indexed: 11/26/2022]
Abstract
The continuous emerging of microfluidic compact disc (CD) platforms for various real-life applications motivates researchers to explore new innovative ideas towards more integrated active functions. However, microfluidic CDs have some drawbacks, including the unidirectional flow that limits the usable space for multi-stepped biological and chemical assays. In this work, a novel active and bidirectional centrifugal pump is developed and integrated on microfluidic CDs. The design of the developed pump partially replicates the designs of the conventional centrifugal pumps with a modification in the connecting channels' positions that allow the developed pump to be reversible. The main advantage of the proposed centrifugal pump is that the pumping speed can be accurately controlled during spinning or while the microfluidic CD is stationary. Performance tests show that the pumping speed can reach up to 164.93 mm3/s at a pump rotational speed (impellers speed) of 4288 rpm. At that speed, 1 mL of water could be pumped in 6.06 s. To present a few of the potential applications of the centrifugal pump, flow reciprocation, bidirectional pumping, and flow switching were performed and evaluated. Results show that the developed centrifugal pump can pump 1096 µL of liquid towards the CD center at 87% pumping efficiency while spinning the microfluidic CD at 250 rpm. This novel centrifugal pump can significantly widen the range of the applicability of microfluidic CDs in advanced chemical processes and biological assays.
Collapse
Affiliation(s)
- Ala’aldeen Al-Halhouli
- NanoLab, School of Applied Technical Sciences, German Jordanian University (GJU), Amman 11180, Jordan; (A.A.); (W.A.-F.)
- Institut für Mikrotechnik, Technische Universität Braunschweig, 38106 Braunschweig, Germany
- Faculty of Engineering, Middle East University, Amman 11831, Jordan
| | - Baha El Far
- School of Engineering and Technology, Central Michigan University, Mount Pleasant, MI 48859, USA;
| | - Ahmed Albagdady
- NanoLab, School of Applied Technical Sciences, German Jordanian University (GJU), Amman 11180, Jordan; (A.A.); (W.A.-F.)
| | - Wisam Al-Faqheri
- NanoLab, School of Applied Technical Sciences, German Jordanian University (GJU), Amman 11180, Jordan; (A.A.); (W.A.-F.)
| |
Collapse
|
18
|
Dudala S, Dubey SK, Goel S. Fully Integrated, Automated, and Smartphone Enabled Point-of-Source Portable Platform With Microfluidic Device for Nitrite Detection. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:1518-1524. [PMID: 31494558 DOI: 10.1109/tbcas.2019.2939658] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Excess limit of Nitrites, which are prevalent within environmental and physiological systems, have severe detrimental effects, thus point-of-source detection becomes an important requirement to take suitable preventive measures. This paper presents the design and development of a standalone, point-of-source, portable, low-cost, automated and integrated microfluidic system for quick detection and quantification of nitrite. Based on multiphysics simulations, a disposable polydimethylsiloxane (PDMS) microfluidic device was employed to carry out the controlled Griess reaction based assay. A low-cost 3D printed syringe pump was developed to inject the sample and reagent. Photometric detection was employed using light emitting diode (LED) and photodiode. A transimpedance amplifier circuit was designed and fabricated to achieve amplified photodiode output with reduced noise. An off-the-shelf microprocessor was used to integrate the whole system and a smartphone application (app) was developed to control the complete system and store the data. Interaction between the application and the microprocessor was achieved using Bluetooth connectivity. Spectrophotometric validation was performed and a calibration equation was obtained which was used to convert the device voltage output to absorption, through specially programmed android app. All the components were integrated in a 3D printed platform whose virtues such as ease of usage and affordability makes, quantification of nitrite, a simple and real time process wherein the limit of detection and limit of quantification values are found to be 0.07103 ppm and 0.21524 ppm respectively with good repeatability.
Collapse
|
19
|
Fornells E, Murray E, Waheed S, Morrin A, Diamond D, Paull B, Breadmore M. Integrated 3D printed heaters for microfluidic applications: Ammonium analysis within environmental water. Anal Chim Acta 2019; 1098:94-101. [PMID: 31948591 DOI: 10.1016/j.aca.2019.11.025] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Revised: 10/30/2019] [Accepted: 11/07/2019] [Indexed: 12/20/2022]
Abstract
A multi-material 3D printed microfluidic reactor with integrated heating is presented, which was applied within a manifold for the colorimetric determination of ammonium in natural waters. Graphene doped polymer was used to provide localised heating when connected to a power source, achieving temperatures of up to 120 °C at 12 V, 0.7 A. An electrically insulating layer of acrylonitrile butadiene styrene (ABS) polymer or a new microdiamond-ABS polymer composite was used as a heater coating. The microdiamond polymer composite provided higher thermal conductivity and uniform heating of the serpentine microreactor which resulted in greater temperature control and accuracy in comparison to pure ABS polymer. The developed heater was then applied and demonstrated using a modified Berthelot reaction for ammonium analysis, in which the microreactor was configured at a predetermined optimised temperature. A 5-fold increase in reaction speed was observed compared to previously reported reaction rates. A simple flow injection analysis set up, comprising the microfluidic heater along with an LED-photodiode based optical detector, was assembled for ammonium analysis. Two river water samples and two blind ammonium standards were analysed and estimated concentrations were compared to concentrations determined using benchtop IC. The highest relative error observed following the analysis of the environmental samples was 11% and for the blind standards was 5%.
Collapse
Affiliation(s)
- Elisenda Fornells
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Sandy Bay, Hobart, 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Sandy Bay, Hobart, 7001, Australia
| | - Eoin Murray
- Research & Development, T.E. Laboratories Ltd. (TelLab), Tullow, Carlow, Ireland; Insight Centre for Data Analytics, National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - Sidra Waheed
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Sandy Bay, Hobart, 7001, Australia; ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Sandy Bay, Hobart, 7001, Australia
| | - Aoife Morrin
- Insight Centre for Data Analytics, National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - Dermot Diamond
- Insight Centre for Data Analytics, National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - Brett Paull
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Sandy Bay, Hobart, 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Sandy Bay, Hobart, 7001, Australia; ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Sandy Bay, Hobart, 7001, Australia
| | - Michael Breadmore
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Sandy Bay, Hobart, 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Sandy Bay, Hobart, 7001, Australia.
| |
Collapse
|
20
|
Jaywant SA, Arif KM. A Comprehensive Review of Microfluidic Water Quality Monitoring Sensors. SENSORS (BASEL, SWITZERLAND) 2019; 19:E4781. [PMID: 31684136 PMCID: PMC6864743 DOI: 10.3390/s19214781] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 10/29/2019] [Accepted: 10/31/2019] [Indexed: 12/20/2022]
Abstract
Water crisis is a global issue due to water contamination and extremely restricted sources of fresh water. Water contamination induces severe diseases which put human lives at risk. Hence, water quality monitoring has become a prime activity worldwide. The available monitoring procedures are inadequate as most of them require expensive instrumentation, longer processing time, tedious processes, and skilled lab technicians. Therefore, a portable, sensitive, and selective sensor with in situ and continuous water quality monitoring is the current necessity. In this context, microfluidics is the promising technology to fulfill this need due to its advantages such as faster reaction times, better process control, reduced waste generation, system compactness and parallelization, reduced cost, and disposability. This paper presents a review on the latest enhancements of microfluidic-based electrochemical and optical sensors for water quality monitoring and discusses the relative merits and shortcomings of the methods.
Collapse
Affiliation(s)
- Swapna A Jaywant
- Department of Mechanical and Electrical Engineering, SF&AT, Massey University, Auckland 0632, New Zealand.
| | - Khalid Mahmood Arif
- Department of Mechanical and Electrical Engineering, SF&AT, Massey University, Auckland 0632, New Zealand.
| |
Collapse
|
21
|
Lace A, Ryan D, Bowkett M, Cleary J. Chromium Monitoring in Water by Colorimetry Using Optimised 1,5-Diphenylcarbazide Method. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16101803. [PMID: 31117215 PMCID: PMC6571720 DOI: 10.3390/ijerph16101803] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Revised: 05/02/2019] [Accepted: 05/18/2019] [Indexed: 12/23/2022]
Abstract
Chromium contamination of drinking water has become a global problem due to its extensive use in industry. The most commonly used methods for chromium detection in water are laboratory-based methods, such as atomic absorption spectroscopy and mass spectroscopy. Although these methods are highly selective and sensitive, they require expensive maintenance and highly trained staff. Therefore, there is a growing demand for cost effective and portable detection methods that would meet the demand for mass monitoring. Microfluidic detection systems based on optical detection have great potential for onsite monitoring applications. Furthermore, their small size enables rapid sample throughput and minimises both reagent consumption and waste generation. In contrast to standard laboratory methods, there is also no requirement for sample transport and storage. The aim of this study is to optimise a colorimetric method based on 1,5-diphenylcarbazide dye for incorporation into a microfluidic detection system. Rapid colour development was observed after the addition of the dye and samples were measured at 543 nm. Beer's law was obeyed in the range between 0.03-3 mg·L-1. The detection limit and quantitation limit were found to be 0.023 and 0.076 mg·L-1, respectively.
Collapse
Affiliation(s)
- Annija Lace
- EnviroCORE, Department of Science and Health, Institute of Technology Carlow, Kilkenny Road, Co. Carlow R93 V960, Ireland.
| | - David Ryan
- EnviroCORE, Department of Science and Health, Institute of Technology Carlow, Kilkenny Road, Co. Carlow R93 V960, Ireland.
| | - Mark Bowkett
- TE Laboratories Ltd. (TelLab), Loughmartin Business Park, Tullow, Co. Carlow R93 N529, Ireland.
| | - John Cleary
- EnviroCORE, Department of Science and Health, Institute of Technology Carlow, Kilkenny Road, Co. Carlow R93 V960, Ireland.
| |
Collapse
|
22
|
Khanfar MF, Abu Eisheh NJ, Al-Ghussain L, Al-Halhouli AT. Lab on a Chip for the Colorimetric Determination of Nitrite in Processed Meat Products in the Jordanian Market. MICROMACHINES 2019; 10:E36. [PMID: 30621098 PMCID: PMC6356477 DOI: 10.3390/mi10010036] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2018] [Revised: 12/28/2018] [Accepted: 01/04/2019] [Indexed: 12/21/2022]
Abstract
Nitrite and Nitrate have been used extensively as additives in various meat products to enhance flavor, color, and to preserve the meat from the bacterial growth. High concentrations of nitrite can threat human health since several studies in the literature claim that nitrite is associated with cancer incidences, leukemia, and brain tumors. Therefore, it is vital to measure the nitrite concentrations in processed meat products. In this study, an in-lab miniaturized photometric detection system is fabricated to inspect the nitrite concentration in processed meat products in Jordan. The analytical performance of nitrite detection is evaluated based on three key statistical parameters; linearity, limit of detection, and limit of quantitation. Respectively, for the fabricated system, the three values are found to be equal to 0.995, 1.24 × 10-2 ppm, and 4.12 × 10-2 ppm. Adherence to Beer's law is found over the investigated range from 2.63 ppm to 96.0 ppm. The developed system is utilized for photometric detection of nitrite in processed meat products available in the Jordanian market like pastrami, salami, and corned beef. In all of the analyzed samples, the nitrite content is found to be lower than 150 ppm, which represents the maximum allowable nitrite limit.
Collapse
Affiliation(s)
- Mohammad F Khanfar
- Department of Pharmaceutical and Chemical Engineering, School of Applied Medical Sciences, German Jordanian University, Amman 11180, Jordan.
| | - Nour J Abu Eisheh
- Department of Pharmaceutical and Chemical Engineering, School of Applied Medical Sciences, German Jordanian University, Amman 11180, Jordan.
| | - Loiy Al-Ghussain
- NanoLab, Mechatronice Engineering Department, School of Applied Technical Sciences, German Jordanian University, Amman 11180, Jordan.
| | - Ala'aldeen T Al-Halhouli
- NanoLab, Mechatronice Engineering Department, School of Applied Technical Sciences, German Jordanian University, Amman 11180, Jordan.
| |
Collapse
|
23
|
Amperometric sensor based on carbon dots decorated self-assembled 3D flower-like β-Ni(OH)2 nanosheet arrays for the determination of nitrite. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.08.132] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|