1
|
Choi W, Park H, Oh S, Seok S, Yoon DS, Kim J. High-Porosity Sieve-Type Neural Electrodes for Motor Function Recovery and Nerve Signal Acquisition. MICROMACHINES 2024; 15:862. [PMID: 39064373 PMCID: PMC11279187 DOI: 10.3390/mi15070862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Revised: 06/27/2024] [Accepted: 06/28/2024] [Indexed: 07/28/2024]
Abstract
In this study, the effects of electrode porosity on nerve regeneration and functional recovery after sciatic nerve transection in rats was investigated. A sieve-type neural electrode with 70% porosity was designed and compared with an electrode with 30% porosity. Electrodes were fabricated from photosensitive polyimide and implanted into the transected sciatic nerves. Motor function recovery was evaluated using the Sciatic Function Index. The number of active channels and their signal quality were recorded and analyzed to assess the sensory neural signal acquisition. Electrical impedance spectroscopy was used to evaluate the electrode performance. The group implanted with the 70% porosity electrode demonstrated significantly enhanced nerve regeneration and motor function recovery, approaching control group levels by the fifth week. In contrast, the group with the 30% porosity electrode exhibited limited improvement. Immunohistochemical analysis confirmed extensive nerve fiber growth within the 70% porous structure. Moreover, the 70% porosity electrode consistently acquired neural signals from more channels compared to the 30% porosity electrode, demonstrating its superior performance in sensory signal detection. These findings emphasize the importance of optimizing electrode porosity in the development of advanced neural interfaces, with the potential to enhance clinical outcomes in peripheral nerve repair and neuroprosthetic applications.
Collapse
Affiliation(s)
- Wonsuk Choi
- Center for Bionics, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; (W.C.); (H.P.); (S.O.)
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - HyungDal Park
- Center for Bionics, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; (W.C.); (H.P.); (S.O.)
| | - Seonghwan Oh
- Center for Bionics, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; (W.C.); (H.P.); (S.O.)
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Seonho Seok
- Center for Nanoscience and Nanotechnology (C2N), University-Paris-Saclay, 91400 Orsay, France;
| | - Dae Sung Yoon
- School of Biomedical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Jinseok Kim
- Center for Bionics, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; (W.C.); (H.P.); (S.O.)
| |
Collapse
|
2
|
Taghlabi KM, Cruz-Garza JG, Hassan T, Potnis O, Bhenderu LS, Guerrero JR, Whitehead RE, Wu Y, Luan L, Xie C, Robinson JT, Faraji AH. Clinical outcomes of peripheral nerve interfaces for rehabilitation in paralysis and amputation: a literature review. J Neural Eng 2024; 21:011001. [PMID: 38237175 DOI: 10.1088/1741-2552/ad200f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 01/18/2024] [Indexed: 02/02/2024]
Abstract
Peripheral nerve interfaces (PNIs) are electrical systems designed to integrate with peripheral nerves in patients, such as following central nervous system (CNS) injuries to augment or replace CNS control and restore function. We review the literature for clinical trials and studies containing clinical outcome measures to explore the utility of human applications of PNIs. We discuss the various types of electrodes currently used for PNI systems and their functionalities and limitations. We discuss important design characteristics of PNI systems, including biocompatibility, resolution and specificity, efficacy, and longevity, to highlight their importance in the current and future development of PNIs. The clinical outcomes of PNI systems are also discussed. Finally, we review relevant PNI clinical trials that were conducted, up to the present date, to restore the sensory and motor function of upper or lower limbs in amputees, spinal cord injury patients, or intact individuals and describe their significant findings. This review highlights the current progress in the field of PNIs and serves as a foundation for future development and application of PNI systems.
Collapse
Affiliation(s)
- Khaled M Taghlabi
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Jesus G Cruz-Garza
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Taimur Hassan
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Medicine, Texas A&M University, Bryan, TX 77807, United States of America
| | - Ojas Potnis
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Engineering Medicine, Texas A&M University, Houston, TX 77030, United States of America
| | - Lokeshwar S Bhenderu
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Medicine, Texas A&M University, Bryan, TX 77807, United States of America
| | - Jaime R Guerrero
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Rachael E Whitehead
- Department of Academic Affairs, Houston Methodist Academic Institute, Houston, TX 77030, United States of America
| | - Yu Wu
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Lan Luan
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Chong Xie
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Jacob T Robinson
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Amir H Faraji
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| |
Collapse
|
3
|
Ionescu ON, Franti E, Carbunaru V, Moldovan C, Dinulescu S, Ion M, Dragomir DC, Mihailescu CM, Lascar I, Oproiu AM, Neagu TP, Costea R, Dascalu M, Teleanu MD, Ionescu G, Teleanu R. System of Implantable Electrodes for Neural Signal Acquisition and Stimulation for Wirelessly Connected Forearm Prosthesis. BIOSENSORS 2024; 14:31. [PMID: 38248408 PMCID: PMC10813559 DOI: 10.3390/bios14010031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/31/2023] [Accepted: 01/02/2024] [Indexed: 01/23/2024]
Abstract
There is great interest in the development of prosthetic limbs capable of complex activities that are wirelessly connected to the patient's neural system. Although some progress has been achieved in this area, one of the main problems encountered is the selective acquisition of nerve impulses and the closing of the automation loop through the selective stimulation of the sensitive branches of the patient. Large-scale research and development have achieved so-called "cuff electrodes"; however, they present a big disadvantage: they are not selective. In this article, we present the progress made in the development of an implantable system of plug neural microelectrodes that relate to the biological nerve tissue and can be used for the selective acquisition of neuronal signals and for the stimulation of specific nerve fascicles. The developed plug electrodes are also advantageous due to their small thickness, as they do not trigger nerve inflammation. In addition, the results of the conducted tests on a sous scrofa subject are presented.
Collapse
Affiliation(s)
- Octavian Narcis Ionescu
- Faculty of Mechanical and Electrical Engineering, Petroleum and Gas University from Ploiesti, 100680 Ploiesti, Romania; (O.N.I.); (G.I.)
- National Institute for Research and Development for Microtechnology Bucharest, 077190 Bucharest, Romania; (C.M.); (S.D.); (M.I.); (D.C.D.); (C.M.M.)
| | - Eduard Franti
- National Institute for Research and Development for Microtechnology Bucharest, 077190 Bucharest, Romania; (C.M.); (S.D.); (M.I.); (D.C.D.); (C.M.M.)
- ICIA, Centre of New Electronic Architectures, 061071 Bucharest, Romania;
| | - Vlad Carbunaru
- Emergency Clinic Hospital Bucharest, 014461 Bucharest, Romania; (V.C.); (I.L.); (A.M.O.); (T.P.N.)
- University of Medicine and Pharmacy UMF Carol Davila, 050474 Bucharest, Romania; (M.D.T.); (R.T.)
| | - Carmen Moldovan
- National Institute for Research and Development for Microtechnology Bucharest, 077190 Bucharest, Romania; (C.M.); (S.D.); (M.I.); (D.C.D.); (C.M.M.)
| | - Silviu Dinulescu
- National Institute for Research and Development for Microtechnology Bucharest, 077190 Bucharest, Romania; (C.M.); (S.D.); (M.I.); (D.C.D.); (C.M.M.)
| | - Marian Ion
- National Institute for Research and Development for Microtechnology Bucharest, 077190 Bucharest, Romania; (C.M.); (S.D.); (M.I.); (D.C.D.); (C.M.M.)
| | - David Catalin Dragomir
- National Institute for Research and Development for Microtechnology Bucharest, 077190 Bucharest, Romania; (C.M.); (S.D.); (M.I.); (D.C.D.); (C.M.M.)
| | - Carmen Marinela Mihailescu
- National Institute for Research and Development for Microtechnology Bucharest, 077190 Bucharest, Romania; (C.M.); (S.D.); (M.I.); (D.C.D.); (C.M.M.)
| | - Ioan Lascar
- Emergency Clinic Hospital Bucharest, 014461 Bucharest, Romania; (V.C.); (I.L.); (A.M.O.); (T.P.N.)
- University of Medicine and Pharmacy UMF Carol Davila, 050474 Bucharest, Romania; (M.D.T.); (R.T.)
| | - Ana Maria Oproiu
- Emergency Clinic Hospital Bucharest, 014461 Bucharest, Romania; (V.C.); (I.L.); (A.M.O.); (T.P.N.)
- University of Medicine and Pharmacy UMF Carol Davila, 050474 Bucharest, Romania; (M.D.T.); (R.T.)
| | - Tiberiu Paul Neagu
- Emergency Clinic Hospital Bucharest, 014461 Bucharest, Romania; (V.C.); (I.L.); (A.M.O.); (T.P.N.)
- University of Medicine and Pharmacy UMF Carol Davila, 050474 Bucharest, Romania; (M.D.T.); (R.T.)
| | - Ruxandra Costea
- Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine of Bucharest, 011464 Bucharest, Romania;
| | - Monica Dascalu
- ICIA, Centre of New Electronic Architectures, 061071 Bucharest, Romania;
- Faculty of Electronics, Telecommunications and Information Technology, National University of Science and Technology Politehnica of Bucharest, 060042 Bucharest, Romania
| | - Mihai Daniel Teleanu
- University of Medicine and Pharmacy UMF Carol Davila, 050474 Bucharest, Romania; (M.D.T.); (R.T.)
| | - Gabriela Ionescu
- Faculty of Mechanical and Electrical Engineering, Petroleum and Gas University from Ploiesti, 100680 Ploiesti, Romania; (O.N.I.); (G.I.)
| | - Raluca Teleanu
- University of Medicine and Pharmacy UMF Carol Davila, 050474 Bucharest, Romania; (M.D.T.); (R.T.)
| |
Collapse
|
4
|
Mascia A, Spanu A, Bonfiglio A, Cosseddu P. Multimodal force and temperature tactile sensor based on a short-channel organic transistor with high sensitivity. Sci Rep 2023; 13:16232. [PMID: 37758843 PMCID: PMC10533849 DOI: 10.1038/s41598-023-43360-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 09/22/2023] [Indexed: 09/29/2023] Open
Abstract
In this manuscript, we report on a novel architecture for the fabrication of highly sensitive multimodal tactile transducers, for the simultaneous detection of temperature and force. Such devices are based on a flexible Organic Charge Modulated Field Effect Transistor (OCMFET) coupled with a pyro/piezoelectric element, namely a commercial film of poly-vinylene difluoride (PVDF). The reduction of the channel length, obtained by employing a low-resolution vertical channel architecture, allowed to maximize the ratio between the sensing area and the transistor's channel area, a technological approach that allows to considerably enhance both temperature and force sensitivity, while at the same time minimize the sensor's dimensions. Thanks to the employment of a straightforward, up-scalable, and highly reproducible fabrication process, this solution represents an interesting alternative for all those applications requiring high-density, high-sensitivity sensors such as robotics and biomedical applications.
Collapse
Affiliation(s)
- Antonello Mascia
- Department of Electrical and Electronic Engineering, University of Cagliari, via Marengo, Cagliari, 09123, Italy
| | - Andrea Spanu
- Department of Science, Technology and Society, Scuola Universitaria Superiore IUSS, Palazzo del Broletto, Piazza della Vittoria 15, Pavia, 27100, Italy
| | - Annalisa Bonfiglio
- Department of Electrical and Electronic Engineering, University of Cagliari, via Marengo, Cagliari, 09123, Italy
- Department of Science, Technology and Society, Scuola Universitaria Superiore IUSS, Palazzo del Broletto, Piazza della Vittoria 15, Pavia, 27100, Italy
| | - Piero Cosseddu
- Department of Electrical and Electronic Engineering, University of Cagliari, via Marengo, Cagliari, 09123, Italy.
| |
Collapse
|
5
|
Lopresto N, Cao P, Koerner LJ, Orser H. Design of a Configurable 16-Electrode Sense and Stimulation Neuromodulation System. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-5. [PMID: 38082855 DOI: 10.1109/embc40787.2023.10340821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Electrical sensing and stimulation of nervous system activity is a valuable tool to investigate neural activity both in vivo and in vitro. A general system capable of supporting users across a variety of use cases would be valuable for the field of neuroscience. We propose a new system capable of supporting a variety of experimental cases including low and high impedance electrodes with stimulation amplitudes up to multiple mA. The system is designed to support sampling frequencies up to 26 kHz and to maximize stimulation flexibility with an electrically isolated system.
Collapse
|
6
|
Liu F, Wu Y, Almarri N, Habibollahi M, Lancashire HT, Bryson B, Greensmith L, Jiang D, Demosthenous A. A Fully Implantable Opto-Electro Closed-Loop Neural Interface for Motor Neuron Disease Studies. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:752-765. [PMID: 36018872 DOI: 10.1109/tbcas.2022.3202026] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
This paper presents a fully implantable closed-loop device for use in freely moving rodents to investigate new treatments for motor neuron disease. The 0.18 μm CMOS integrated circuit comprises 4 stimulators, each featuring 16 channels for optical and electrical stimulation using arbitrary current waveforms at frequencies from 1.5 Hz to 50 kHz, and a bandwidth programmable front-end for neural recording. The implant uses a Qi wireless inductive link which can deliver >100 mW power at a maximum distance of 2 cm for a freely moving rodent. A backup rechargeable battery can support 10 mA continuous stimulation currents for 2.5 hours in the absence of an inductive power link. The implant is controlled by a graphic user interface with broad programmable parameters via a Bluetooth low energy bidirectional data telemetry link. The encapsulated implant is 40 mm × 20 mm × 10 mm. Measured results are presented showing the electrical performance of the electronics and the packaging method.
Collapse
|
7
|
He Y, Corradi F, Shi C, van der Ven S, Timmermans M, Stuijt J, Detterer P, Harpe P, Lindeboom L, Hermeling E, Langereis G, Chicca E, Liu YH. An Implantable Neuromorphic Sensing System Featuring Near-sensor Computation and Send-on-Delta Transmission for Wireless Neural Sensing of Peripheral Nerves. IEEE JOURNAL OF SOLID-STATE CIRCUITS 2022; 57:3058-3070. [PMID: 36741239 PMCID: PMC7614138 DOI: 10.1109/jssc.2022.3193846] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
This paper presents a bio-inspired event-driven neuromorphic sensing system (NSS) capable of performing on-chip feature extraction and "send-on-delta" pulse-based transmission, targeting peripheral-nerve neural recording applications. The proposed NSS employs event-based sampling which, by leveraging the sparse nature of electroneurogram (ENG) signals, achieves a data compression ratio of >125×, while maintaining a low normalized RMS error of 4% after reconstruction. The proposed NSS consists of three sub-circuits. A clockless level-crossing (LC) ADC with background offset calibration has been employed to reduce the data rate, while maintaining a high signal to quantization noise ratio. A fully synthesized spiking neural network (SNN) extracts temporal features of compound action potential signals consumes only 13 μW. An event-driven pulse-based body channel communication (Pulse-BCC) with serialized address-event representation encoding (AER) schemes minimizes transmission energy and form factor. The prototype is fabricated in 40-nm CMOS occupying a 0.32-mm2 active area and consumes in total 28.2 μW and 50 μW power in feature extraction and full diagnosis mode, respectively. The presented NSS also extracts temporal features of compound action potential signals with 10-μs precision.
Collapse
|
8
|
Takeuchi M, Tokutake K, Watanabe K, Ito N, Aoyama T, Saeki S, Kurimoto S, Hirata H, Hasegawa Y. A Wirelessly Powered 4-Channel Neurostimulator for Reconstructing Walking Trajectory. SENSORS (BASEL, SWITZERLAND) 2022; 22:7198. [PMID: 36236295 PMCID: PMC9572656 DOI: 10.3390/s22197198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 09/10/2022] [Accepted: 09/19/2022] [Indexed: 06/16/2023]
Abstract
A wirelessly powered four-channel neurostimulator was developed for applying selective Functional Electrical Stimulation (FES) to four peripheral nerves to control the ankle and knee joints of a rat. The power of the neurostimulator was wirelessly supplied from a transmitter device, and the four nerves were connected to the receiver device, which controlled the ankle and knee joints in the rat. The receiver device had functions to detect the frequency of the transmitter signal from the transmitter coil. The stimulation site of the nerves was selected according to the frequency of the transmitter signal. The rat toe position was controlled by changing the angles of the ankle and knee joints. The joint angles were controlled by the stimulation current applied to each nerve independently. The stimulation currents were adjusted by the Proportional Integral Differential (PID) and feed-forward control method through a visual feedback control system, and the walking trajectory of a rat's hind leg was reconstructed. This study contributes to controlling the multiple joints of a leg and reconstructing functional motions such as walking using the robotic control technology.
Collapse
Affiliation(s)
- Masaru Takeuchi
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Nagoya 464-8601, Japan
| | - Katsuhiro Tokutake
- Department of Human Enhancement and Hand Surgery, Nagoya University, Nagoya 464-8601, Japan
| | - Keita Watanabe
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Nagoya 464-8601, Japan
| | - Naoyuki Ito
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Nagoya 464-8601, Japan
| | - Tadayoshi Aoyama
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Nagoya 464-8601, Japan
| | - Sota Saeki
- Department of Human Enhancement and Hand Surgery, Nagoya University, Nagoya 464-8601, Japan
| | - Shigeru Kurimoto
- Department of Human Enhancement and Hand Surgery, Nagoya University, Nagoya 464-8601, Japan
| | - Hitoshi Hirata
- Department of Human Enhancement and Hand Surgery, Nagoya University, Nagoya 464-8601, Japan
| | - Yasuhisa Hasegawa
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Nagoya 464-8601, Japan
| |
Collapse
|
9
|
Khan SR, Mugisha AJ, Tsiamis A, Mitra S. Commercial Off-the-Shelf Components (COTS) in Realizing Miniature Implantable Wireless Medical Devices: A Review. SENSORS 2022; 22:s22103635. [PMID: 35632042 PMCID: PMC9144583 DOI: 10.3390/s22103635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/25/2022] [Accepted: 04/30/2022] [Indexed: 12/04/2022]
Abstract
Over the past decade, there has been exponential growth in the per capita rate of medical patients around the world, and this is significantly straining the resources of healthcare institutes. Therefore, the reliance on smart commercial off-the-shelf (COTS) implantable wireless medical devices (IWMDs) is increasing among healthcare institutions to provide routine medical services, such as monitoring patients' physiological signals and the remote delivery of therapeutic drugs. These smart COTS IWMDs reduce the necessity of recurring visits of patients to healthcare institutions and also mitigate physical contact, which can minimize the possibility of any potential spread of contagious diseases. Furthermore, the devices provide patients with the benefit of recuperating in familiar surroundings. As such, low-cost, ubiquitous COTS IWMDs have engendered the proliferation of telemedicine in healthcare to provide routine medical services. In this paper, a review work on COTS IWMDs is presented at a macro level to discuss the history of IWMDs, different networked COTS IWMDs, health and safety regulations of COTS IWMDs and the importance of organized procurement. Furthermore, we discuss the basic building blocks of IWMDs and how COTS components can contribute to build these blocks over widely researched custom-built application-specific integrated circuits.
Collapse
|
10
|
Remote Sensing System for Motor Nerve Impulse. SENSORS 2022; 22:s22082823. [PMID: 35458809 PMCID: PMC9027399 DOI: 10.3390/s22082823] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 03/28/2022] [Accepted: 03/30/2022] [Indexed: 12/04/2022]
Abstract
In this article, we present our research achievements regarding the development of a remote sensing system for motor pulse acquisition, as a first step towards a complete neuroprosthetic arm. We present the fabrication process of an implantable electrode for nerve impulse acquisition, together with an innovative wirelessly controlled system. In our study, these were combined into an implantable device for attachment to peripheral nerves. Mechanical and biocompatibility tests were performed, as well as in vivo testing on pigs using the developed system. This testing and the experimental results are presented in a comprehensive manner, demonstrating that the system is capable of accomplishing the requirements of its designed application. Most significantly, neural electrical signals were acquired and transmitted out of the body during animal experiments, which were conducted according to ethical regulations in the field.
Collapse
|
11
|
Park H, Choi W, Oh S, Kim YJ, Seok S, Kim J. A Study on Biocompatible Polymer-Based Packaging of Neural Interface for Chronic Implantation. MICROMACHINES 2022; 13:mi13040516. [PMID: 35457821 PMCID: PMC9027597 DOI: 10.3390/mi13040516] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 03/21/2022] [Accepted: 03/24/2022] [Indexed: 02/05/2023]
Abstract
This paper proposed and verified the use of polymer-based packaging to implement the chronic implantation of neural interfaces using a combination of a commercial thermal epoxy and a thin parylene film. The packaging’s characteristics and the performance of the vulnerable interface between the thermal epoxy layer and polyimide layer, which is mainly used for neural electrodes and an FPCB, were evaluated through in vitro, in vivo, and acceleration experiments. The performance of neural interfaces—composed of the combination of the thermal epoxy and thin parylene film deposition as encapsulation packaging—was evaluated by using signal acquisition experiments based on artificial stimulation signal transmissions through in vitro and in vivo experiments. It has been found that, when commercial thermal epoxy normally cured at room temperature was cured at higher temperatures of 45 °C and 65 °C, not only is its lifetime increased with about twice the room-temperature-based curing conditions but also an interfacial adhesion is higher with more than twice the room-temperature-based curing conditions. In addition, through in vivo experiments using rats, it was confirmed that bodily fluids did not flow into the interface between the thermal epoxy and FPCB for up to 18 months, and it was verified that the rats maintained healthy conditions without occurring an immune response in the body to the thin parylene film deposition on the packaging’s surface.
Collapse
Affiliation(s)
- HyungDal Park
- Center for Bionics, Korea Institute of Science and Technology (KIST), Seoul 02792, Korea; (H.P.); (W.C.); (S.O.)
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Korea
| | - Wonsuk Choi
- Center for Bionics, Korea Institute of Science and Technology (KIST), Seoul 02792, Korea; (H.P.); (W.C.); (S.O.)
- Department of Biomedical Engineering, Korea University, Seoul 02841, Korea
| | - Seonghwan Oh
- Center for Bionics, Korea Institute of Science and Technology (KIST), Seoul 02792, Korea; (H.P.); (W.C.); (S.O.)
- Department of Biomedical Engineering, Korea University, Seoul 02841, Korea
| | - Yong-Jun Kim
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Korea
- Correspondence: (Y.-J.K.); (S.S.); (J.K.)
| | - Seonho Seok
- Center for Nanoscience and Nanotechnology (C2N), University-Paris-Saclay, 91400 Orsay, France
- Correspondence: (Y.-J.K.); (S.S.); (J.K.)
| | - Jinseok Kim
- Center for Bionics, Korea Institute of Science and Technology (KIST), Seoul 02792, Korea; (H.P.); (W.C.); (S.O.)
- Correspondence: (Y.-J.K.); (S.S.); (J.K.)
| |
Collapse
|
12
|
Vėbraitė I, Hanein Y. Soft Devices for High-Resolution Neuro-Stimulation: The Interplay Between Low-Rigidity and Resolution. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 3:675744. [PMID: 35047928 PMCID: PMC8757739 DOI: 10.3389/fmedt.2021.675744] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Accepted: 05/14/2021] [Indexed: 12/27/2022] Open
Abstract
The field of neurostimulation has evolved over the last few decades from a crude, low-resolution approach to a highly sophisticated methodology entailing the use of state-of-the-art technologies. Neurostimulation has been tested for a growing number of neurological applications, demonstrating great promise and attracting growing attention in both academia and industry. Despite tremendous progress, long-term stability of the implants, their large dimensions, their rigidity and the methods of their introduction and anchoring to sensitive neural tissue remain challenging. The purpose of this review is to provide a concise introduction to the field of high-resolution neurostimulation from a technological perspective and to focus on opportunities stemming from developments in materials sciences and engineering to reduce device rigidity while optimizing electrode small dimensions. We discuss how these factors may contribute to smaller, lighter, softer and higher electrode density devices.
Collapse
Affiliation(s)
- Ieva Vėbraitė
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Yael Hanein
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
13
|
New Stimulation Device to Drive Multiple Transverse Intrafascicular Electrodes and Achieve Highly Selective and Rich Neural Responses. SENSORS 2021; 21:s21217219. [PMID: 34770527 PMCID: PMC8587292 DOI: 10.3390/s21217219] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 10/24/2021] [Accepted: 10/26/2021] [Indexed: 11/25/2022]
Abstract
Peripheral Nerve Stimulation (PNS) is a promising approach in functional restoration following neural impairments. Although it proves to be advantageous in the number of implantation sites provided compared with intramuscular or epimysial stimulation and the fact that it does not require daily placement, as is the case with surface electrodes, the further advancement of PNS paradigms is hampered by the limitation of spatial selectivity due to the current spread and variations of nerve physiology. New electrode designs such as the Transverse Intrafascicular Multichannel Electrode (TIME) were proposed to resolve this issue, but their use was limited by a lack of innovative multichannel stimulation devices. In this study, we introduce a new portable multichannel stimulator—called STIMEP—and implement different stimulation protocols in rats to test its versatility and unveil the potential of its combined use with TIME electrodes in rehabilitation protocols. We developed and tested various stimulation paradigms in a single fascicle and thereafter implanted two TIMEs. We also tested its stimulation using two different waveforms. The results highlighted the versatility of this new stimulation device and advocated for the parameterizing of a hyperpolarizing phase before depolarization as well as the use of small pulse widths when stimulating with multiple electrodes.
Collapse
|
14
|
Shupe LE, Miles FP, Jones G, Yun R, Mishler J, Rembado I, Murphy RL, Perlmutter SI, Fetz EE. Neurochip3: An Autonomous Multichannel Bidirectional Brain-Computer Interface for Closed-Loop Activity-Dependent Stimulation. Front Neurosci 2021; 15:718465. [PMID: 34489634 PMCID: PMC8417105 DOI: 10.3389/fnins.2021.718465] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Accepted: 07/22/2021] [Indexed: 11/13/2022] Open
Abstract
Toward addressing many neuroprosthetic applications, the Neurochip3 (NC3) is a multichannel bidirectional brain-computer interface that operates autonomously and can support closed-loop activity-dependent stimulation. It consists of four circuit boards populated with off-the-shelf components and is sufficiently compact to be carried on the head of a non-human primate (NHP). NC3 has six main components: (1) an analog front-end with an Intan biophysical signal amplifier (16 differential or 32 single-ended channels) and a 3-axis accelerometer, (2) a digital control system comprised of a Cyclone V FPGA and Atmel SAM4 MCU, (3) a micro SD Card for 128 GB or more storage, (4) a 6-channel differential stimulator with ±60 V compliance, (5) a rechargeable battery pack supporting autonomous operation for up to 24 h and, (6) infrared transceiver and serial ports for communication. The NC3 and earlier versions have been successfully deployed in many closed-loop operations to induce synaptic plasticity and bridge lost biological connections, as well as deliver activity-dependent intracranial reinforcement. These paradigms to strengthen or replace impaired connections have many applications in neuroprosthetics and neurorehabilitation.
Collapse
Affiliation(s)
- Larry E Shupe
- Department of Physiology & Biophysics, University of Washington, Seattle, WA, United States.,Washington National Primate Research Center, University of Washington, Seattle, WA, United States
| | - Frank P Miles
- Washington National Primate Research Center, University of Washington, Seattle, WA, United States
| | - Geoff Jones
- Independent Researcher, Seattle, CA, United States
| | - Richy Yun
- Department of Bioengineering, University of Washington, Seattle, WA, United States
| | - Jonathan Mishler
- Department of Bioengineering, University of Washington, Seattle, WA, United States
| | - Irene Rembado
- Department of Physiology & Biophysics, University of Washington, Seattle, WA, United States
| | - R Logan Murphy
- Department of Physiology & Biophysics, University of Washington, Seattle, WA, United States
| | - Steve I Perlmutter
- Department of Physiology & Biophysics, University of Washington, Seattle, WA, United States.,Washington National Primate Research Center, University of Washington, Seattle, WA, United States
| | - Eberhard E Fetz
- Department of Physiology & Biophysics, University of Washington, Seattle, WA, United States.,Washington National Primate Research Center, University of Washington, Seattle, WA, United States.,Department of Bioengineering, University of Washington, Seattle, WA, United States
| |
Collapse
|
15
|
Turner BL, Senevirathne S, Kilgour K, McArt D, Biggs M, Menegatti S, Daniele MA. Ultrasound-Powered Implants: A Critical Review of Piezoelectric Material Selection and Applications. Adv Healthc Mater 2021; 10:e2100986. [PMID: 34235886 DOI: 10.1002/adhm.202100986] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 06/15/2021] [Indexed: 12/14/2022]
Abstract
Ultrasound-powered implants (UPIs) represent cutting edge power sources for implantable medical devices (IMDs), as their powering strategy allows for extended functional lifetime, decreased size, increased implant depth, and improved biocompatibility. IMDs are limited by their reliance on batteries. While batteries proved a stable power supply, batteries feature relatively large sizes, limited life spans, and toxic material compositions. Accordingly, energy harvesting and wireless power transfer (WPT) strategies are attracting increasing attention by researchers as alternative reliable power sources. Piezoelectric energy scavenging has shown promise for low power applications. However, energy scavenging devices need be located near sources of movement, and the power stream may suffer from occasional interruptions. WPT overcomes such challenges by more stable, on-demand power to IMDs. Among the various forms of WPT, ultrasound powering offers distinct advantages such as low tissue-mediated attenuation, a higher approved safe dose (720 mW cm-2 ), and improved efficiency at smaller device sizes. This study presents and discusses the state-of-the-art in UPIs by reviewing piezoelectric materials and harvesting devices including lead-based inorganic, lead-free inorganic, and organic polymers. A comparative discussion is also presented of the functional material properties, architecture, and performance metrics, together with an overview of the applications where UPIs are being deployed.
Collapse
Affiliation(s)
- Brendan L. Turner
- Joint Department of Biomedical Engineering North Carolina State University and University of North Carolina Chapel Hill, 911 Oval Dr. Raleigh NC 27695 USA
| | - Seedevi Senevirathne
- The Patrick G Johnston Centre for Cancer Research Queen's University 97 Lisburn Rd Belfast BT9 7AE UK
| | - Katie Kilgour
- Department of Chemical and Biomolecular Engineering North Carolina State University Raleigh NC 27695 USA
| | - Darragh McArt
- The Patrick G Johnston Centre for Cancer Research Queen's University 97 Lisburn Rd Belfast BT9 7AE UK
| | - Manus Biggs
- Centre for Research in Medical Devices National University of Ireland Newcastle Road Galway H91 W2TY Ireland
| | - Stefano Menegatti
- Department of Chemical and Biomolecular Engineering North Carolina State University Raleigh NC 27695 USA
| | - Michael A. Daniele
- Joint Department of Biomedical Engineering North Carolina State University and University of North Carolina Chapel Hill, 911 Oval Dr. Raleigh NC 27695 USA
- Department of Electrical and Computer Engineering North Carolina State University 890 Oval Dr. Raleigh NC 27695 USA
| |
Collapse
|
16
|
Telyshev D, Nesterenko I, Bochkov A, Malinina A, Markov A, Bordovsky S, Polunin G, Ananichuk A, Reshetov I. Functional Evaluation of Larynx Nerve Stimulator With EMG Acquisition Capability and Wireless Connectivity. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:629-641. [PMID: 34232890 DOI: 10.1109/tbcas.2021.3094890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Recently, an electrical stimulation of the paralyzed muscle, as a potential therapy for restoring function of a denervated muscle system, has been debated as an innovative treatment in the management of patients with laryngeal paralysis. Numerous studies in acute and chronic animal models have demonstrated that electrical stimulation of the paralyzed posterior cricoarytenoideus muscle (PCA) offers an approach to induce vocal fold abduction and restore ventilation through the glottis. The study aims to test applicability of the controlled opening of the rima glottides via direct electrical stimulation of the posterior cricoarytenoideus muscle. We developed for this purpose a novel instrument system for the controlled larynx nerve stimulation. An acute experiment on the 4 years old pig showed effectiveness of the engineered stimulator. The controlled opening of rima glottidis of both posterior cricoarytenoid muscles and afterwards of both PCA muscle contraction were observed as a result of the electrical stimulation with the applied current in the range of 0.1-3 mA and pulse width of 1 ms and 10 ms. Performed research indicates a large potential of the novel nerve stimulator for the human larynx stimulation.
Collapse
|
17
|
Stuart T, Cai L, Burton A, Gutruf P. Wireless and battery-free platforms for collection of biosignals. Biosens Bioelectron 2021; 178:113007. [PMID: 33556807 PMCID: PMC8112193 DOI: 10.1016/j.bios.2021.113007] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 01/02/2021] [Accepted: 01/14/2021] [Indexed: 02/06/2023]
Abstract
Recent progress in biosensors have quantitively expanded current capabilities in exploratory research tools, diagnostics and therapeutics. This rapid pace in sensor development has been accentuated by vast improvements in data analysis methods in the form of machine learning and artificial intelligence that, together, promise fantastic opportunities in chronic sensing of biosignals to enable preventative screening, automated diagnosis, and tools for personalized treatment strategies. At the same time, the importance of widely accessible personal monitoring has become evident by recent events such as the COVID-19 pandemic. Progress in fully integrated and chronic sensing solutions is therefore increasingly important. Chronic operation, however, is not truly possible with tethered approaches or bulky, battery-powered systems that require frequent user interaction. A solution for this integration challenge is offered by wireless and battery-free platforms that enable continuous collection of biosignals. This review summarizes current approaches to realize such device architectures and discusses their building blocks. Specifically, power supplies, wireless communication methods and compatible sensing modalities in the context of most prevalent implementations in target organ systems. Additionally, we highlight examples of current embodiments that quantitively expand sensing capabilities because of their use of wireless and battery-free architectures.
Collapse
Affiliation(s)
- Tucker Stuart
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Le Cai
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Alex Burton
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Philipp Gutruf
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA; Department of Electrical Engineering, University of Arizona, Tucson, AZ, 85721, USA; Bio5 Institute, University of Arizona, Tucson, AZ, 85721, USA; Neuroscience GIDP, University of Arizona, Tucson, AZ, 85721, USA.
| |
Collapse
|
18
|
Shon A, Brakel K, Hook M, Park H. Fully Implantable Plantar Cutaneous Augmentation System for Rats Using Closed-loop Electrical Nerve Stimulation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:326-338. [PMID: 33861705 DOI: 10.1109/tbcas.2021.3072894] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Plantar cutaneous feedback plays an important role in stable and efficient gait, by modulating the activity of ankle dorsi- and plantar-flexor muscles. However, central and peripheral nervous system trauma often decrease plantar cutaneous feedback and/or interneuronal excitability in processing the plantar cutaneous feedback. In this study, we tested a fully implantable neural recording and stimulation system augmenting plantar cutaneous feedback. Electromyograms were recorded from the medial gastrocnemius muscle for stance phase detection, while biphasic stimulation pulses were applied to the distal-tibial nerve during the stance phase to augment plantar cutaneous feedback. A Bluetooth low energy and a Qi-standard inductive link were adopted for wireless communication and wireless charging, respectively. To test the operation of the system, one intact rat walked on a treadmill with the electrical system implanted into its back. Leg kinematics were recorded to identify the stance phase. Stimulation was applied, with a 250-ms onset delay from stance onset and 200-ms duration, resulting in the onset at 47.58 ± 2.82% of stance phase and the offset at 83.49 ± 4.26% of stance phase (Mean ± SEM). The conduction velocity of the compound action potential (31.2 m/s and 41.6 m/s at 1·T and 2·T, respectively) suggests that the evoked action potential was characteristic of an afferent volley for cutaneous feedback. We also demonstrated successful wireless charging and system reset functions. The experimental results suggest that the presented implantable system can be a valuable neural interface tool to investigate the effect of plantar cutaneous augmentation on gait in a rat model.
Collapse
|
19
|
Abstract
Peripheral nerve interfaces (PNIs) record and/or modulate neural activity of nerves, which are responsible for conducting sensory-motor information to and from the central nervous system, and for regulating the activity of inner organs. PNIs are used both in neuroscience research and in therapeutical applications such as precise closed-loop control of neuroprosthetic limbs, treatment of neuropathic pain and restoration of vital functions (e.g. breathing and bladder management). Implantable interfaces represent an attractive solution to directly access peripheral nerves and provide enhanced selectivity both in recording and in stimulation, compared to their non-invasive counterparts. Nevertheless, the long-term functionality of implantable PNIs is limited by tissue damage, which occurs at the implant-tissue interface, and is thus highly dependent on material properties, biocompatibility and implant design. Current research focuses on the development of mechanically compliant PNIs, which adapt to the anatomy and dynamic movements of nerves in the body thereby limiting foreign body response. In this paper, we review recent progress in the development of flexible and implantable PNIs, highlighting promising solutions related to materials selection and their associated fabrication methods, and integrated functions. We report on the variety of available interface designs (intraneural, extraneural and regenerative) and different modulation techniques (electrical, optical, chemical) emphasizing the main challenges associated with integrating such systems on compliant substrates.
Collapse
Affiliation(s)
- Valentina Paggi
- Bertarelli Foundation Chair in Neuroprosthetic Technology, Laboratory for Soft Bioelectronic Interfaces, Institute of Microengineering, Institute of Bioengineering, Centre for Neuroprosthetics, Ecole Polytechnique Fédérale de Lausanne (EPFL), 1202 Geneva, Switzerland. Equally contributing authors
| | | | | | | |
Collapse
|
20
|
Shon A, Brakel K, Hook M, Park H. Closed-Loop Plantar Cutaneous Augmentation by Electrical Nerve Stimulation Increases Ankle Plantarflexion During Treadmill Walking. IEEE Trans Biomed Eng 2021; 68:2798-2809. [PMID: 33497323 DOI: 10.1109/tbme.2021.3054564] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Ankle plantarflexion plays an important role in forward propulsion and anterior-posterior balance during locomotion. This component of gait is often critically impacted by neurotraumas and neurological diseases. We hypothesized that augmenting plantar cutaneous feedback, via closed-loop distal-tibial nerve stimulation, could increase ankle plantarflexion during walking. To test the hypothesis, one intact rat walked on a motorized treadmill with implanted electronic device and electrodes for closed-loop neural recording and stimulation. Constant-current biphasic electrical pulse train was applied to distal-tibial nerve, based on electromyogram recorded from the medial gastrocnemius muscle, to be timed with the stance phase. The stimulation current threshold to evoke plantar cutaneous feedback was set at 30 μA (1·T), based on compound action potential evoked by stimulation. The maximum ankle joint angle at plantarflexion, during the application of stimulation currents of 3.3·T and 6.6·T, respectively, was increased from 149.4° (baseline) to 165.4° and 161.6°. The minimum ankle joint angle at dorsiflexion was decreased from 59.4° (baseline) to 53.1°, during the application of stimulation currents of 3.3·T, but not changed by 6.6·T. Plantar cutaneous augmentation also changed other gait kinematic parameters. Stance duty factor was increased from 51.9% (baseline) to 65.7% and 64.0%, respectively, by 3.3·T and 6.6·T, primarily due to a decrease in swing duration. Cycle duration was consistently decreased by the stimulation. In the control trial after two stimulation trials, a strong after-effect was detected in overall gait kinematics as well as ankle plantarflexion, suggesting that this stimulation has the potential for producing long-term changes in gait kinematics.
Collapse
|
21
|
Cho Y, Park J, Lee C, Lee S. Recent progress on peripheral neural interface technology towards bioelectronic medicine. Bioelectron Med 2020; 6:23. [PMID: 33292861 PMCID: PMC7706233 DOI: 10.1186/s42234-020-00059-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 11/05/2020] [Indexed: 11/23/2022] Open
Abstract
Modulation of the peripheral nervous system (PNS) has a great potential for therapeutic intervention as well as restore bodily functions. Recent interest has focused on autonomic nerves, as they regulate extensive functions implicated in organ physiology, chronic disease state and appear tractable to targeted modulation of discrete nerve units. Therapeutic interventions based on specific bioelectronic neuromodulation depend on reliable neural interface to stimulate and record autonomic nerves. Furthermore, the function of stimulation and recording requires energy which should be delivered to the interface. Due to the physiological and anatomical challenges of autonomic nerves, various forms of this active neural interface need to be developed to achieve next generation of neural interface for bioelectronic medicine. In this article, we present an overview of the state-of-the-art for peripheral neural interface technology in relation to autonomic nerves. Also, we reveal the current status of wireless neural interface for peripheral nerve applications. Recent studies of a novel concept of self-sustainable neural interface without battery and electronic components are presented. Finally, the recent results of non-invasive stimulation such as ultrasound and magnetic stimulation are covered and the perspective of the future research direction is provided.
Collapse
Affiliation(s)
- Youngjun Cho
- Daegu Geongbuk Institute of Science and Technology (DGIST), Daegu, 42899, Republic of Korea
| | - Jaeu Park
- Daegu Geongbuk Institute of Science and Technology (DGIST), Daegu, 42899, Republic of Korea
| | - Chengkuo Lee
- Electrical & Computer Engineering, National University of Singapore, Singapore, 117583, Singapore. .,Center for Intelligent Sensors and MEMS (CISM), National University of Singapore, Singapore, 117608, Singapore. .,NUS Graduate School for Integrated Science and Engineering (NGS), National University of Singapore, Singapore, 117456, Singapore.
| | - Sanghoon Lee
- Daegu Geongbuk Institute of Science and Technology (DGIST), Daegu, 42899, Republic of Korea.
| |
Collapse
|
22
|
Williams I, Brunton E, Rapeaux A, Liu Y, Luan S, Nazarpour K, Constandinou T. SenseBack - An Implantable System for Bidirectional Neural Interfacing. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; PP:1079-1087. [PMID: 32915746 DOI: 10.1109/tbcas.2020.3022839] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Chronic in-vivo neurophysiology experiments require highly miniaturized, remotely powered multi-channel neural interfaces which are currently lacking in power or flexibility post implantation. To resolve this problem we present the SenseBack system, a post-implantation reprogrammable wireless 32-channel bidirectional neural interfacing device that can enable chronic peripheral electrophysiology experiments in freely behaving small animals. The large number of channels for a peripheral neural interface, coupled with fully implantable hardware and complete software flexibility enable complex in-vivo studies where the system can adapt to evolving study needs as they arise. In complementary \textit{ex-vivo} and \textit{in-vivo} preparations, we demonstrate that this system can record neural signals and perform high-voltage, bipolar stimulation on any channel. In addition, we demonstrate transcutaneous power delivery and Bluetooth 5 data communication with a PC. The SenseBack system is capable of stimulation on any channel with 20 V of compliance and up to 315 A of current, and highly configurable recording with per-channel adjustable gain and filtering with 8 sets of 10-bit ADCs to sample data at 20 kHz for each channel. To our knowledge this is the first such implantable research platform offering this level of performance and flexibility post-implantation (including complete reprogramming even after encapsulation) for small animal electrophysiology. Here we present initial acute trials, demonstrations and progress towards a system that we expect to enable a wide range of electrophysiology experiments in freely behaving animals.
Collapse
|
23
|
Rodrigues D, Barbosa AI, Rebelo R, Kwon IK, Reis RL, Correlo VM. Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review. BIOSENSORS-BASEL 2020; 10:bios10070079. [PMID: 32708103 PMCID: PMC7400150 DOI: 10.3390/bios10070079] [Citation(s) in RCA: 72] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 07/07/2020] [Accepted: 07/16/2020] [Indexed: 12/21/2022]
Abstract
Biosensors devices have attracted the attention of many researchers across the world. They have the capability to solve a large number of analytical problems and challenges. They are future ubiquitous devices for disease diagnosis, monitoring, treatment and health management. This review presents an overview of the biosensors field, highlighting the current research and development of bio-integrated and implanted biosensors. These devices are micro- and nano-fabricated, according to numerous techniques that are adapted in order to offer a suitable mechanical match of the biosensor to the surrounding tissue, and therefore decrease the body’s biological response. For this, most of the skin-integrated and implanted biosensors use a polymer layer as a versatile and flexible structural support, combined with a functional/active material, to generate, transmit and process the obtained signal. A few challenging issues of implantable biosensor devices, as well as strategies to overcome them, are also discussed in this review, including biological response, power supply, and data communication.
Collapse
Affiliation(s)
- Daniela Rodrigues
- 3B’s Research Group, I3Bs—Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal; (D.R.); (A.I.B.); (R.R.); (I.K.K.); (R.L.R.)
| | - Ana I. Barbosa
- 3B’s Research Group, I3Bs—Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal; (D.R.); (A.I.B.); (R.R.); (I.K.K.); (R.L.R.)
- ICVS/3B’s—PT Government Associate Laboratory, 4710-057 Braga, Portugal
| | - Rita Rebelo
- 3B’s Research Group, I3Bs—Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal; (D.R.); (A.I.B.); (R.R.); (I.K.K.); (R.L.R.)
- ICVS/3B’s—PT Government Associate Laboratory, 4710-057 Braga, Portugal
| | - Il Keun Kwon
- 3B’s Research Group, I3Bs—Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal; (D.R.); (A.I.B.); (R.R.); (I.K.K.); (R.L.R.)
| | - Rui L. Reis
- 3B’s Research Group, I3Bs—Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal; (D.R.); (A.I.B.); (R.R.); (I.K.K.); (R.L.R.)
- ICVS/3B’s—PT Government Associate Laboratory, 4710-057 Braga, Portugal
- Department of Dental Materials, School of Dentistry, Kyung Hee University, 26 Kyungheedae-ro, Dongdaemun-gu, Seoul 02447, Korea
| | - Vitor M. Correlo
- 3B’s Research Group, I3Bs—Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal; (D.R.); (A.I.B.); (R.R.); (I.K.K.); (R.L.R.)
- ICVS/3B’s—PT Government Associate Laboratory, 4710-057 Braga, Portugal
- Correspondence:
| |
Collapse
|
24
|
Visual Feedback Control of a Rat Ankle Angle Using a Wirelessly Powered Two-Channel Neurostimulator. SENSORS 2020; 20:s20082210. [PMID: 32295158 PMCID: PMC7218912 DOI: 10.3390/s20082210] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 04/04/2020] [Accepted: 04/10/2020] [Indexed: 02/01/2023]
Abstract
Peripheral nerve disconnections cause severe muscle atrophy and consequently, paralysis of limbs. Reinnervation of denervated muscle by transplanting motor neurons and applying Functional Electrical Stimulation (FES) onto peripheral nerves is an important procedure for preventing irreversible degeneration of muscle tissues. After the reinnervation of denervated muscles, multiple peripheral nerves should be stimulated independently to control joint motion and reconstruct functional movements of limbs by the FES. In this study, a wirelessly powered two-channel neurostimulator was developed with the purpose of applying selective FES to two peripheral nerves—the peroneal nerve and the tibial nerve in a rat. The neurostimulator was designed in such a way that power could be supplied wirelessly, from a transmitter coil to a receiver coil. The receiver coil was connected, in turn, to the peroneal and tibial nerves in the rat. The receiver circuit had a low pass filter to allow detection of the frequency of the transmitter signal. The stimulation of the nerves was switched according to the frequency of the transmitter signal. Dorsal/plantar flexion of the rat ankle joint was selectively induced by the developed neurostimulator. The rat ankle joint angle was controlled by changing the stimulation electrode and the stimulation current, based on the Proportional Integral (PI) control method using a visual feedback control system. This study was aimed at controlling the leg motion by stimulating the peripheral nerves using the neurostimulator.
Collapse
|
25
|
Yu X, Su JY, Guo JY, Zhang XH, Li RH, Chai XY, Chen Y, Zhang DG, Wang JG, Sui XH, Durand DM. Spatiotemporal characteristics of neural activity in tibial nerves with carbon nanotube yarn electrodes. J Neurosci Methods 2019; 328:108450. [PMID: 31577919 DOI: 10.1016/j.jneumeth.2019.108450] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 09/25/2019] [Accepted: 09/27/2019] [Indexed: 10/25/2022]
Abstract
BACKGROUND Reliable interfacing with peripheral nervous system is essential to extract neural signals. Current implantable peripheral nerve electrodes cannot provide long-term reliable interfaces due to their mechanical mismatch with host nerves. Carbon nanotube (CNT) yarns possess excellent mechanical flexibility and electrical conductivity. It is of great necessity to investigate the selectivity of implantable CNT yarn electrodes. NEW METHOD Neural interfaces were fabricated with CNT yarn electrodes insulated with Parylene-C. Acute recordings were carried out on tibial nerves of rats, and compound nerve action potentials (CNAPs) were electrically evoked by biphasic current stimulation of four toes. Spatiotemporal characteristics of neural activity and spatial selectivity of the electrodes, denoted by selectivity index (SI), were analyzed in detail. RESULTS Conduction velocities of sensory afferent fibers recorded by CNT yarn electrodes varied between 4.25 m/s and 37.56 m/s. The SI maxima for specific toes were between 0.55 and 0.99 across seven electrodes. SIs for different CNT yarn electrodes are significantly different among varied toes. COMPARISON WITH EXISTING METHODS Most single CNT yarn electrode with a ∼ 500 μm exposed length can be sensitive to one or two specific toes in rodent animals. While, it is only possible to discriminate two non-adjacent toes by multisite TIME electrodes. CONCLUSION Single CNT yarn electrode exposed ∼ 500 μm showed SI values for different toes comparable to a multisite TIME electrode, and had high spatial selectivity for one or two specific toes. The electrodes with cross section exposed could intend to be more sensitive to one specific toe.
Collapse
Affiliation(s)
- X Yu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - J Y Su
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - J Y Guo
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - X H Zhang
- Innovation Center for Textile Science and Technology, Donghua University, Shanghai, China
| | - R H Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - X Y Chai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Y Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - D G Zhang
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - J G Wang
- Shanghai Institute of Hypertension, Department of Hypertension, Shanghai Jiao Tong University School of Medicine Affiliated Ruijin Hospital, Shanghai, China
| | - X H Sui
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
| | - D M Durand
- Neural Engineering Center, Department of Biomedical Engineering, Case Western Reserve University, Cleveland, USA.
| |
Collapse
|
26
|
Sliow A, Ma Z, Gargiulo G, Mahns D, Mawad D, Breen P, Stoodley M, Houang J, Kuchel R, Tettamanzi GC, Tilley RD, Frost SJ, Morley J, Longo L, Lauto A. Stimulation and Repair of Peripheral Nerves Using Bioadhesive Graft-Antenna. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2019; 6:1801212. [PMID: 31179205 PMCID: PMC6548953 DOI: 10.1002/advs.201801212] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 03/05/2019] [Indexed: 06/09/2023]
Abstract
An original wireless stimulator for peripheral nerves based on a metal loop (diameter ≈1 mm) that is powered by a transcranial magnetic stimulator (TMS) and does not require circuitry components is reported. The loop can be integrated in a chitosan scaffold that functions as a graft when applied onto transected nerves (graft-antenna). The graft-antenna is bonded to rat sciatic nerves by a laser without sutures; it does not migrate after implantation and is able to trigger steady compound muscle action potentials for 12 weeks (CMAP ≈1.3 mV). Eight weeks postoperatively, axon regeneration is facilitated in transected nerves that are repaired with the graft-antenna and stimulated by the TMS for 1 h per week. The graft-antenna is an innovative and minimally-invasive device that functions concurrently as a wireless stimulator and adhesive scaffold for nerve repair.
Collapse
Affiliation(s)
- Ashour Sliow
- School of Science and HealthWestern Sydney UniversityLocked Bag 1797PenrithNSW2751Australia
| | - Zhi Ma
- School of MedicineWestern Sydney UniversityPenrithNSW2751Australia
| | - Gaetano Gargiulo
- Biomedical Engineering & Neuroscience Research GroupMARCS InstituteWestern Sydney UniversityPenrithNSW2751Australia
| | - David Mahns
- School of MedicineWestern Sydney UniversityPenrithNSW2751Australia
| | - Damia Mawad
- School of Materials Science and EngineeringUniversity of New South WalesKensingtonNSW2052Australia
| | - Paul Breen
- Biomedical Engineering & Neuroscience Research GroupMARCS InstituteWestern Sydney UniversityPenrithNSW2751Australia
| | - Marcus Stoodley
- The Australian School of Advanced MedicineMacquarie UniversityNorth RydeNSW2109Australia
| | - Jessica Houang
- School of Aerospace, Mechanical and Mechatronic EngineeringUniversity of SydneySydneyNSW2006Australia
| | - Rhiannon Kuchel
- Mark Wainwright Analytical CentreUniversity of New South WalesKensingtonNSW2052Australia
| | - Giuseppe C. Tettamanzi
- School of Physical Sciences and Institute for Photonics and Advanced SensingUniversity of AdelaideAdelaideSA5005Australia
| | - Richard D. Tilley
- Mark Wainwright Analytical CentreUniversity of New South WalesKensingtonNSW2052Australia
| | - Samuel J. Frost
- School of Science and HealthWestern Sydney UniversityLocked Bag 1797PenrithNSW2751Australia
| | - John Morley
- School of MedicineWestern Sydney UniversityPenrithNSW2751Australia
| | - Leonardo Longo
- Faculty of Human SciencesUniversity of the Republic of San MarinoContrada Omerelli47890Republic of San Marino
| | - Antonio Lauto
- School of Science and HealthWestern Sydney UniversityLocked Bag 1797PenrithNSW2751Australia
- School of MedicineWestern Sydney UniversityPenrithNSW2751Australia
- Biomedical Engineering & Neuroscience Research GroupMARCS InstituteWestern Sydney UniversityPenrithNSW2751Australia
| |
Collapse
|
27
|
Pan Y, Mu N, Liu B, Cao B, Wang W, Yang L. A Novel Surface Acoustic Wave Sensor Array Based on Wireless Communication Network. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2977. [PMID: 30200649 PMCID: PMC6164968 DOI: 10.3390/s18092977] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 09/04/2018] [Accepted: 09/04/2018] [Indexed: 11/16/2022]
Abstract
A novel surface acoustic wave (SAW) sensor array based on wireless communication network is prepared. The array is composed of four SAW sensors, a wireless communication network module, and a global positioning system (GPS) module. The four SAW sensors of the array are coated with triethanolamine, polyepichlorohydrin, fluoroalcoholpolysiloxane, and L-glutamic acid hydrochloride to detect hydrogen sulfide (H₂S), 2-chloroethyl ethyl sulfide (CEES), dimethylmethylphosphonate (DMMP), and ammonia (NH₃) at film thicknesses of 50⁻100 nm. The wireless communication network module consists of an acquisition unit, a wireless control unit, and a microcontroller unit. By means of Zigbee and Lora technologies, the module receives and transmits the collected data to a PC work station in real-time; moreover, the module can control the sensor array's working mode and monitor the working status. Simultaneously, the testing location is determined by the GPS module integrated into the SAW sensor array. H₂S, CEES, DMMP, and NH₃ are detected in 300 m at different concentrations. Given the practical future application in environment in the future, the low, safe concentrations of 1.08, 0.59, 0.10, and 5.02 ppm for H₂S, CEES, DMMP, and NH₃, respectively, are detected at the lowest concentration, and the sensitivities of different sensors of the sensor array are 32.4, 14.9, 78.1 and 22.6 Hz/ppm, respectively. With the obtained fingerprints and pattern recognition technology, the detected gases can be recognized.
Collapse
Affiliation(s)
- Yong Pan
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
| | - Ning Mu
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
| | - Bo Liu
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
| | - Bingqing Cao
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
| | - Wen Wang
- State Key Laboratory of Acoustics, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China.
| | - Liu Yang
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
| |
Collapse
|