1
|
Davarinia F, Maleki A. EMG and SSVEP-based bimodal estimation of elbow angle trajectory. Neuroscience 2024; 562:1-9. [PMID: 39454713 DOI: 10.1016/j.neuroscience.2024.10.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 09/06/2024] [Accepted: 10/15/2024] [Indexed: 10/28/2024]
Abstract
Detecting intentions and estimating movement trajectories in a human-machine interface (HMI) using electromyogram (EMG) signals is particularly challenging, especially for individuals with movement impairments. Therefore, incorporating additional information from other biological sources, potential discrete information in the movement, and the EMG signal can be practical. This study combined EMG and target information to enhance estimation performance during reaching movements. EMG activity of the shoulder and arm muscles, elbow angle, and the electroencephalogram signals of ten healthy subjects were recorded while they reached blinking targets. The reaching target was recognized by steady-state visual evoked potential (SSVEP). The selected target's final angle and EMG were then mapped to the elbow angle trajectory. The proposed bimodal structure, which integrates EMG and final elbow angle information, outperformed the EMG-based decoder. Even under conditions of higher fatigue, the proposed structure provided better performance than the EMG decoder. Including additional information about the recognized reaching target in the trajectory model improved the estimation of the reaching profile. Consequently, this study's findings suggest that bimodal decoders are highly beneficial for enhancing assistive robotic devices and prostheses, especially for real-time upper limb rehabilitation.
Collapse
Affiliation(s)
| | - Ali Maleki
- Biomedical Engineering Department, Semnan University, Semnan, Iran.
| |
Collapse
|
2
|
Sherif O, Bassuoni MM, Mehrez O. A survey on the state of the art of force myography technique (FMG): analysis and assessment. Med Biol Eng Comput 2024; 62:1313-1332. [PMID: 38305814 PMCID: PMC11021344 DOI: 10.1007/s11517-024-03019-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2023] [Accepted: 01/09/2024] [Indexed: 02/03/2024]
Abstract
Precise feedback assures precise control commands especially for assistive or rehabilitation devices. Biofeedback systems integrated with assistive or rehabilitative robotic exoskeletons tend to increase its performance and effectiveness. Therefore, there has been plenty of research in the field of biofeedback covering different aspects such as signal acquisition, conditioning, feature extraction and integration with the control system. Among several types of biofeedback systems, Force myography (FMG) technique is a promising one in terms of affordability, high classification accuracies, ease to use, and low computational cost. Compared to traditional biofeedback systems such as electromyography (EMG) which offers some invasive techniques, FMG offers a completely non-invasive solution with much less effort for preprocessing with high accuracies. This work covers the whole aspects of FMG technique in terms of signal acquisition, feature extraction, signal processing, developing the machine learning model, evaluating tools for the performance of the model. Stating the difference between real-time and offline assessment, also highlighting the main uncovered points for further study, and thus enhancing the development of this technique.
Collapse
Affiliation(s)
- Omar Sherif
- Mechanical Power Engineering Department, Faculty of Engineering, Tanta University, Tanta, Egypt.
| | | | - Omar Mehrez
- Mechanical Power Engineering Department, Faculty of Engineering, Tanta University, Tanta, Egypt
| |
Collapse
|
3
|
Wang H, Ding Q, Luo Y, Wu Z, Yu J, Chen H, Zhou Y, Zhang H, Tao K, Chen X, Fu J, Wu J. High-Performance Hydrogel Sensors Enabled Multimodal and Accurate Human-Machine Interaction System for Active Rehabilitation. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2309868. [PMID: 38095146 DOI: 10.1002/adma.202309868] [Citation(s) in RCA: 22] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 12/03/2023] [Indexed: 12/22/2023]
Abstract
Human-machine interaction (HMI) technology shows an important application prospect in rehabilitation medicine, but it is greatly limited by the unsatisfactory recognition accuracy and wearing comfort. Here, this work develops a fully flexible, conformable, and functionalized multimodal HMI interface consisting of hydrogel-based sensors and a self-designed flexible printed circuit board. Thanks to the component regulation and structural design of the hydrogel, both electromyogram (EMG) and forcemyography (FMG) signals can be collected accurately and stably, so that they are later decoded with the assistance of artificial intelligence (AI). Compared with traditional multichannel EMG signals, the multimodal human-machine interaction method based on the combination of EMG and FMG signals significantly improves the efficiency of human-machine interaction by increasing the information entropy of the interaction signals. The decoding accuracy of the interaction signals from only two channels for different gestures reaches 91.28%. The resulting AI-powered active rehabilitation system can control a pneumatic robotic glove to assist stroke patients in completing movements according to the recognized human motion intention. Moreover, this HMI interface is further generalized and applied to other remote sensing platforms, such as manipulators, intelligent cars, and drones, paving the way for the design of future intelligent robot systems.
Collapse
Affiliation(s)
- Hao Wang
- State Key Laboratory of Optoelectronic Materials and Technologies and the Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou, 510275, China
| | - Qiongling Ding
- State Key Laboratory of Optoelectronic Materials and Technologies and the Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou, 510275, China
| | - Yibing Luo
- State Key Laboratory of Optoelectronic Materials and Technologies and the Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou, 510275, China
| | - Zixuan Wu
- State Key Laboratory of Optoelectronic Materials and Technologies and the Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou, 510275, China
| | - Jiahao Yu
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, Northwestern Polytechnical University, Xi'an, 710072, China
| | - Huizhi Chen
- Guangdong Provincial Key Laboratory of Research and Development of Natural Drugs and School of Pharmacy, Guangdong Medical University, Dongguan, 523808, P. R. China
- The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan, 523808, P. R. China
| | - Yubin Zhou
- Guangdong Provincial Key Laboratory of Research and Development of Natural Drugs and School of Pharmacy, Guangdong Medical University, Dongguan, 523808, P. R. China
- The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan, 523808, P. R. China
| | - He Zhang
- Guangdong Provincial Key Laboratory of Technique and Equipment for Macromolecular Advanced Manufacturing, National Engineering Research Center of Novel Equipment for Polymer Processing, Key Laboratory of Polymer Processing Engineering (SCUT) Ministry of Education, South China University of Technology, Guangzhou, 510641, P. R. China
| | - Kai Tao
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, Northwestern Polytechnical University, Xi'an, 710072, China
| | - Xiaoliang Chen
- Micro- and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Jun Fu
- School of Materials Science and Engineering, Sun Yat-sen University, Guangzhou, 510275, China
| | - Jin Wu
- State Key Laboratory of Optoelectronic Materials and Technologies and the Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzhou, 510275, China
- Guangdong Provincial Key Laboratory of Technique and Equipment for Macromolecular Advanced Manufacturing, National Engineering Research Center of Novel Equipment for Polymer Processing, Key Laboratory of Polymer Processing Engineering (SCUT) Ministry of Education, South China University of Technology, Guangzhou, 510641, P. R. China
- State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, 610065, People's Republic of China
| |
Collapse
|
4
|
Olsen RJ, Hasan SS, Woo JJ, Nawabi DH, Ramkumar PN. The Fundamentals and Applications of Wearable Sensor Devices in Sports Medicine: A Scoping Review. Arthroscopy 2024:S0749-8063(24)00098-7. [PMID: 38331364 DOI: 10.1016/j.arthro.2024.01.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 01/28/2024] [Accepted: 01/30/2024] [Indexed: 02/10/2024]
Abstract
PURPOSE To (1) characterize the various forms of wearable sensor devices (WSDs) and (2) review the peer-reviewed literature of applied wearable technology within sports medicine. METHODS A systematic search of PubMed and EMBASE databases, from inception through 2023, was conducted to identify eligible studies using WSDs within sports medicine. Data extraction was performed of study demographics and sensor specifications. Included studies were categorized by application: athletic training, rehabilitation, and research. RESULTS In total, 43 studies met criteria for inclusion in this review. Forms of WSDs include pedometers, accelerometers, encoders (consisting of magnetometers and gyroscopes), force sensors, global positioning system trackers, and inertial measurement units. Outcome metrics include step counts; gait, limb motion, and angular positioning; foot and skin pressure; change of direction and inclination, including analysis of both body parts and athletes on a field; displacement and velocity of body segments and joints; heart rate; plethysmography; sport-specific kinematics; range of motion, symmetry, and alignment; head impact; sleep; throwing biomechanics; and kinetic and spatiotemporal running metrics. WSDs are used in athletic training to assess sport-specific biomechanics and workload with a goal of injury prevention and training optimization, as well as for rehabilitation monitoring and research such as for risk predicting and aiding diagnosis. CONCLUSIONS WSDs enable real-time monitoring of human performance across a variety of implementations and settings, allowing collection of metrics otherwise not achievable. WSDs are powerful tools with multiple applications within athletic training, patient rehabilitation, and orthopaedic and sports medicine research. CLINICAL RELEVANCE Wearable technology may represent the missing link to quantitatively addressing return to play and previous performance. WSDs are commercially available and portable adjuncts that allow clinicians, trainers, and individual athletes to monitor biomechanical parameters, workload, and recovery status to better contextualize personalized training, injury risk, and rehabilitation.
Collapse
Affiliation(s)
- Reena J Olsen
- Sports Medicine Institute, Hospital for Special Surgery, New York, New York, U.S.A
| | | | - Joshua J Woo
- Brown University/The Warren Alpert School of Brown University, Providence, Rhode Island, U.S.A
| | - Danyal H Nawabi
- Sports Medicine Institute, Hospital for Special Surgery, New York, New York, U.S.A
| | - Prem N Ramkumar
- Long Beach Orthopedic Institute, Long Beach, California, U.S.A..
| |
Collapse
|
5
|
Sziburis T, Nowak M, Brunelli D. Instance-based learning with prototype reduction for real-time proportional myocontrol: a randomized user study demonstrating accuracy-preserving data reduction for prosthetic embedded systems. Med Biol Eng Comput 2024; 62:275-305. [PMID: 37796400 PMCID: PMC10758379 DOI: 10.1007/s11517-023-02917-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 08/21/2023] [Indexed: 10/06/2023]
Abstract
This work presents the design, implementation and validation of learning techniques based on the kNN scheme for gesture detection in prosthetic control. To cope with high computational demands in instance-based prediction, methods of dataset reduction are evaluated considering real-time determinism to allow for the reliable integration into battery-powered portable devices. The influence of parameterization and varying proportionality schemes is analyzed, utilizing an eight-channel-sEMG armband. Besides offline cross-validation accuracy, success rates in real-time pilot experiments (online target achievement tests) are determined. Based on the assessment of specific dataset reduction techniques' adequacy for embedded control applications regarding accuracy and timing behaviour, decision surface mapping (DSM) proves itself promising when applying kNN on the reduced set. A randomized, double-blind user study was conducted to evaluate the respective methods (kNN and kNN with DSM-reduction) against ridge regression (RR) and RR with random Fourier features (RR-RFF). The kNN-based methods performed significantly better ([Formula: see text]) than the regression techniques. Between DSM-kNN and kNN, there was no statistically significant difference (significance level 0.05). This is remarkable in consideration of only one sample per class in the reduced set, thus yielding a reduction rate of over 99% while preserving success rate. The same behaviour could be confirmed in an extended user study. With [Formula: see text], which turned out to be an excellent choice, the runtime complexity of both kNN (in every prediction step) as well as DSM-kNN (in the training phase) becomes linear concerning the number of original samples, favouring dependable wearable prosthesis applications.
Collapse
Affiliation(s)
- Tim Sziburis
- Institute for Neuroinformatics (INI), Ruhr University Bochum, Universitätsstr. 150, Bochum, 44801, Germany.
- German Aerospace Center (DLR), Robotics and Mechatronics Center (RMC), Münchener Str. 20, 82234, Weßling, Germany.
| | - Markus Nowak
- German Aerospace Center (DLR), Robotics and Mechatronics Center (RMC), Münchener Str. 20, 82234, Weßling, Germany
| | - Davide Brunelli
- Department of Industrial Engineering, DII, University of Trento, Via Sommarive, 9, 38123, Trento, Italy
| |
Collapse
|
6
|
Scarborough DM, Linderman SE, Aspenleiter R, Berkson EM. Quantifying muscle contraction with a conductive electroactive polymer sensor: introduction to a novel surface mechanomyography device. Int Biomech 2023; 10:1-10. [PMID: 38419418 PMCID: PMC10906126 DOI: 10.1080/23335432.2024.2319068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Accepted: 02/11/2024] [Indexed: 03/02/2024] Open
Abstract
Clinicians seek an accurate method to assess muscle contractility during activities to better guide treatment. We investigated application of a conductive electroactive polymer sensor as a novel wearable surface mechanomyography (sMMG) sensor for quantifying muscle contractility. The radial displacement of a muscle during a contraction is detected by the physically stretched dielectric elastomer component of the sMMG sensor which quantifies the changes in capacitance. The duration of muscle activation times for quadriceps, hamstrings, and gastrocnemius muscles demonstrated strong correlation between sMMG and EMG during a parallel squat activity and isometric contractions. A moderate to strong correlation was demonstrated between the sMMG isometric muscle activation times and force output times from a dynamometer. The potential wearable application of an electroactive polymer sensor to measure muscle contraction time is supported.
Collapse
Affiliation(s)
| | - Shannon E. Linderman
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts, USA
| | | | - Eric M. Berkson
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts, USA
| |
Collapse
|
7
|
Rehman MU, Shah K, Haq IU, Iqbal S, Ismail MA. A Wearable Force Myography-Based Armband for Recognition of Upper Limb Gestures. SENSORS (BASEL, SWITZERLAND) 2023; 23:9357. [PMID: 38067728 PMCID: PMC10708660 DOI: 10.3390/s23239357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Revised: 11/15/2023] [Accepted: 11/16/2023] [Indexed: 12/18/2023]
Abstract
Force myography (FMG) represents a promising alternative to surface electromyography (EMG) in the context of controlling bio-robotic hands. In this study, we built upon our prior research by introducing a novel wearable armband based on FMG technology, which integrates force-sensitive resistor (FSR) sensors housed in newly designed casings. We evaluated the sensors' characteristics, including their load-voltage relationship and signal stability during the execution of gestures over time. Two sensor arrangements were evaluated: arrangement A, featuring sensors spaced at 4.5 cm intervals, and arrangement B, with sensors distributed evenly along the forearm. The data collection involved six participants, including three individuals with trans-radial amputations, who performed nine upper limb gestures. The prediction performance was assessed using support vector machines (SVMs) and k-nearest neighbor (KNN) algorithms for both sensor arrangments. The results revealed that the developed sensor exhibited non-linear behavior, and its sensitivity varied with the applied force. Notably, arrangement B outperformed arrangement A in classifying the nine gestures, with an average accuracy of 95.4 ± 2.1% compared to arrangement A's 91.3 ± 2.3%. The utilization of the arrangement B armband led to a substantial increase in the average prediction accuracy, demonstrating an improvement of up to 4.5%.
Collapse
Affiliation(s)
- Mustafa Ur Rehman
- Department of Mechatronics Engineering, University of Engineering and Technology Peshawar, Peshawar 25000, Pakistan; (M.U.R.)
| | - Kamran Shah
- Department of Mechatronics Engineering, University of Engineering and Technology Peshawar, Peshawar 25000, Pakistan; (M.U.R.)
- Department of Mechanical Engineering, King Faisal University, Al-Ahsa 31982, Saudi Arabia;
| | - Izhar Ul Haq
- Department of Mechatronics Engineering, University of Engineering and Technology Peshawar, Peshawar 25000, Pakistan; (M.U.R.)
| | - Sajid Iqbal
- Department of Information Systems, King Faisal University, Al-Ahsa 31982, Saudi Arabia;
| | - Mohamed A. Ismail
- Department of Mechanical Engineering, King Faisal University, Al-Ahsa 31982, Saudi Arabia;
| |
Collapse
|
8
|
Hong GAT, Tobalske BW, van Staaveren N, Leishman EM, Widowski TM, Powers DR, Harlander-Matauschek A. Reduction of wing area affects estimated stress in the primary flight muscles of chickens. ROYAL SOCIETY OPEN SCIENCE 2023; 10:230817. [PMID: 38034124 PMCID: PMC10685109 DOI: 10.1098/rsos.230817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 11/08/2023] [Indexed: 12/02/2023]
Abstract
In flying birds, the pectoralis (PECT) and supracoracoideus (SUPRA) generate most of the power required for flight, while the wing feathers create the aerodynamic forces. However, in domestic laying hens, little is known about the architectural properties of these muscles and the forces the wings produce. As housing space increases for commercial laying hens, understanding these properties is important for assuring safe locomotion. We tested the effects of wing area loss on mass, physiological cross-sectional area (PCSA), and estimated muscle stress (EMS) of the PECT and SUPRA in white-feathered laying hens. Treatments included Unclipped (N = 18), Half-Clipped with primaries removed (N = 18) and Fully-Clipped with the primaries and secondaries removed (N = 18). The mass and PCSA of the PECT and SUPRA did not vary significantly with treatment. Thus, laying hen muscle anatomy may be relatively resistant to changes in external wing morphology. We observed significant differences in EMS among treatments, as Unclipped birds exhibited the greatest EMS. This suggests that intact wings provide the greatest stimulus of external force for the primary flight muscles.
Collapse
Affiliation(s)
- Grace A. T. Hong
- Campbell Centre for the Study of Animal Welfare, Department of Animal Biosciences, University of Guelph, 50 Stone Road E, Guelph, Ontario Canada, N1G 2W1
| | - Bret W. Tobalske
- Division of Biological Sciences, University of Montana, 32 Campus Drive, Missoula, MT 59812, USA
| | - Nienke van Staaveren
- Campbell Centre for the Study of Animal Welfare, Department of Animal Biosciences, University of Guelph, 50 Stone Road E, Guelph, Ontario Canada, N1G 2W1
- Centre for Genetic Improvement of Livestock, University of Guelph, 50 Stone Road E, Guelph, Ontario Canada, N1G 2W1
| | - Emily M. Leishman
- Campbell Centre for the Study of Animal Welfare, Department of Animal Biosciences, University of Guelph, 50 Stone Road E, Guelph, Ontario Canada, N1G 2W1
- Centre for Nutrition Modelling, Department of Animal Biosciences, University of Guelph, 50 Stone Road E, Guelph, Ontario Canada, N1G 2W1
| | - Tina M. Widowski
- Campbell Centre for the Study of Animal Welfare, Department of Animal Biosciences, University of Guelph, 50 Stone Road E, Guelph, Ontario Canada, N1G 2W1
| | - Donald R. Powers
- Department of Biology, George Fox University, 414N Meridian St, Newberg, OR 97132, USA
| | - Alexandra Harlander-Matauschek
- Campbell Centre for the Study of Animal Welfare, Department of Animal Biosciences, University of Guelph, 50 Stone Road E, Guelph, Ontario Canada, N1G 2W1
| |
Collapse
|
9
|
Kimoto A, Oishi Y, Machida M. A Wireless 2-Channel Layered EMG/NIRS Sensor System for Local Muscular Activity Evaluation. SENSORS (BASEL, SWITZERLAND) 2023; 23:8394. [PMID: 37896488 PMCID: PMC10610620 DOI: 10.3390/s23208394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 10/03/2023] [Accepted: 10/08/2023] [Indexed: 10/29/2023]
Abstract
A wireless 2-channel layered sensor system that enables electromyography (EMG) and near-infrared spectroscopy (NIRS) measurements at two local positions was developed. The layered sensor consists of a thin silver electrode and a photosensor consisting of a photoemitting diode (LED) or photodiode (PD). The EMG and NIRS signals were simultaneously measured using a pair of electrodes and photosensors for the LED and PD, respectively. Two local muscular activities are presented in detail using layered sensors. In the experiments, EMG and NIRS signals were measured for isometric constant and ramp contractions at each forearm using layered sensors. The results showed that local muscle activity analysis is possible using simultaneous EMG and NIRS signals at each local position.
Collapse
Affiliation(s)
- Akira Kimoto
- Faculty of Science and Engineering, Saga University, Saga 840-8502, Japan (M.M.)
| | | | | |
Collapse
|
10
|
Priyadarshini BS, Mitra R, Manju U. Titania Nanoparticle-Stimulated Ultralow Frequency Detection and High-Pass Filter Behavior of a Flexible Piezoelectric Nanogenerator: A Self-Sustaining Energy Harvester for Active Motion Tracking. ACS APPLIED MATERIALS & INTERFACES 2023; 15:45812-45822. [PMID: 37733300 DOI: 10.1021/acsami.3c07413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
A significant driving force for the fabrication of IoT-compatible smart health gear integrated with multifunctional sensors is the growing trend in fitness and the overall wellness of the human body. In this work, we present an autonomous motion and activity-sensing device based on the efficacious nucleation of the polar β-phase in an electroactive polymer. Representatively, we investigate the nucleating effect of TiO2 nanoparticles on weight-modulated PVDF-HFP films (PT-5, PT-10, and PT-15) and subsequently prototype a sensing device with the film that demonstrates superior β-phase nucleation. The PT-10 film, with an optimal polar β-phase, shows the highest remnant polarization (2Pr) and energy density of 0.36 μC/cm2 and 22.3 mJ/cm3, respectively, at 60 kV/cm. The films mimic a high pass filter at frequencies above 10 KHz with very low impedance and high ac conductivity values. The frequency-dependent impedance studies reveal an effective interfacial polarization between TiO2 nanoparticles and PVDF-HFP, explicitly observed in the low-frequency region. Consequently, the sensor fabricated with PT-10 as the sensing layer exhibits ultralow frequency detection (25 Hz) resulting from the blood flow muscle oxygenation. The device successfully senses voluntary joint movements of the human body and actively tracks a range of motions, from brisk walking to running. Additionally, through repetitive human finger-tapping motion, the nanogenerator lights up multiple light-emitting diodes in series and charges capacitors of varying magnitudes under 50 s. The real-time human motion sensing and movement tracking modalities of the sensor hold promise in the arena of smart wearables, sports biomechanics, and contact-based medical devices.
Collapse
Affiliation(s)
- B Sheetal Priyadarshini
- Materials Chemistry Department, CSIR-Institute of Minerals and Materials Technology, Bhubaneswar, Odisha 751013, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, Uttar Pradesh 201002, India
| | - Rahul Mitra
- Materials Chemistry Department, CSIR-Institute of Minerals and Materials Technology, Bhubaneswar, Odisha 751013, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, Uttar Pradesh 201002, India
| | - Unnikrishnan Manju
- Materials Chemistry Department, CSIR-Institute of Minerals and Materials Technology, Bhubaneswar, Odisha 751013, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, Uttar Pradesh 201002, India
| |
Collapse
|
11
|
Linderman SE, Scarborough DM, Aspenleiter R, Stein HS, Berkson EM. Assessing Quadriceps Muscle Contraction Using a Novel Surface Mechanomyography Sensor during Two Neuromuscular Control Screening Tasks. SENSORS (BASEL, SWITZERLAND) 2023; 23:6031. [PMID: 37447881 DOI: 10.3390/s23136031] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 06/22/2023] [Accepted: 06/22/2023] [Indexed: 07/15/2023]
Abstract
Electromyography (EMG) is the clinical standard for capturing muscle activation data to gain insight into neuromuscular control, yet challenges surrounding data analysis limit its use during dynamic tasks. Surface mechanomyography (sMMG) sensors are novel wearable devices that measure the physical output of muscle excursion during contraction, which may offer potential easy application to assess neuromuscular control. This study aimed to investigate sMMG detection of the timing patterns of muscle contraction compared to EMG. Fifteen healthy participants (mean age = 31.7 ± 9.1 y; eight males and seven females) were donned with EMG and sMMG sensors on their right quadriceps for simultaneous data capture during bilateral deep squats, and a subset performed three sets of repeated unilateral partial squats. No significant difference in the total duration of contraction was detected by EMG and sMMG during bilateral (p = 0.822) and partial (p = 0.246) squats. sMMG and EMG timing did not differ significantly for eccentric (p = 0.414) and concentric (p = 0.462) phases of muscle contraction during bilateral squats. The sMMG magnitude of quadriceps excursion demonstrated excellent intra-session retest reliability for bilateral (ICC3,1 = 0.962 mm) and partial (ICC3,1 = 0.936 mm, n = 10) squats. The sMMG sensors accurately and consistently provided key quadriceps muscle performance metrics during two physical activities commonly used to assess neuromuscular control for injury prevention, rehabilitation, and exercise training.
Collapse
Affiliation(s)
- Shannon E Linderman
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA 02114, USA
| | | | | | - Hannah S Stein
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Eric M Berkson
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, MA 02114, USA
| |
Collapse
|
12
|
Esposito D, Centracchio J, Bifulco P, Andreozzi E. A smart approach to EMG envelope extraction and powerful denoising for human-machine interfaces. Sci Rep 2023; 13:7768. [PMID: 37173364 PMCID: PMC10181995 DOI: 10.1038/s41598-023-33319-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Accepted: 04/11/2023] [Indexed: 05/15/2023] Open
Abstract
Electromyography (EMG) is widely used in human-machine interfaces (HMIs) to measure muscle contraction by computing the EMG envelope. However, EMG is largely affected by powerline interference and motion artifacts. Boards that directly provide EMG envelope, without denoising the raw signal, are often unreliable and hinder HMIs performance. Sophisticated filtering provides high performance but is not viable when power and computational resources must be optimized. This study investigates the application of feed-forward comb (FFC) filters to remove both powerline interferences and motion artifacts from raw EMG. FFC filter and EMG envelope extractor can be implemented without computing any multiplication. This approach is particularly suitable for very low-cost, low-power platforms. The performance of the FFC filter was first demonstrated offline by corrupting clean EMG signals with powerline noise and motion artifacts. The correlation coefficients of the filtered signals envelopes and the true envelopes were greater than 0.98 and 0.94 for EMG corrupted by powerline noise and motion artifacts, respectively. Further tests on real, highly noisy EMG signals confirmed these achievements. Finally, the real-time operation of the proposed approach was successfully tested by implementation on a simple Arduino Uno board.
Collapse
Affiliation(s)
- Daniele Esposito
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125, Naples, Italy
| | - Jessica Centracchio
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125, Naples, Italy.
| | - Paolo Bifulco
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125, Naples, Italy
| | - Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125, Naples, Italy
| |
Collapse
|
13
|
Sharma N, Prakash A, Sharma S. An optoelectronic muscle contraction sensor for prosthetic hand application. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:035009. [PMID: 37012764 DOI: 10.1063/5.0130394] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Accepted: 03/05/2023] [Indexed: 06/19/2023]
Abstract
Surface electromyography (sEMG) is considered an established means for controlling prosthetic devices. sEMG suffers from serious issues such as electrical noise, motion artifact, complex acquisition circuitry, and high measuring costs because of which other techniques have gained attention. This work presents a new optoelectronic muscle (OM) sensor setup as an alternative to the EMG sensor for precise measurement of muscle activity. The sensor integrates a near-infrared light-emitting diode and phototransistor pair along with the suitable driver circuitry. The sensor measures skin surface displacement (that occurs during muscle contraction) by detecting backscattered infrared light from skeletal muscle tissue. With an appropriate signal processing scheme, the sensor was able to produce a 0-5 V output proportional to the muscular contraction. The developed sensor depicted decent static and dynamic features. In detecting muscle contractions from the forearm muscles of subjects, the sensor showed good similarity with the EMG sensor. In addition, the sensor displayed higher signal-to-noise ratio values and better signal stability than the EMG sensor. Furthermore, the OM sensor setup was utilized to control the rotation of the servomotor using an appropriate control scheme. Hence, the developed sensing system can measure muscle contraction information for controlling assistive devices.
Collapse
Affiliation(s)
- Neeraj Sharma
- School of Biomedical Engineering, Indian Institute of Technology (BHU), Varanasi 221005, India
| | - Alok Prakash
- CSIR-National Physical Laboratory, New Delhi 110012, India
| | - Shiru Sharma
- School of Biomedical Engineering, Indian Institute of Technology (BHU), Varanasi 221005, India
| |
Collapse
|
14
|
Rehman MU, Shah K, Haq IU, Iqbal S, Ismail MA, Selimefendigil F. Assessment of Low-Density Force Myography Armband for Classification of Upper Limb Gestures. SENSORS (BASEL, SWITZERLAND) 2023; 23:2716. [PMID: 36904919 PMCID: PMC10007530 DOI: 10.3390/s23052716] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 02/23/2023] [Accepted: 02/24/2023] [Indexed: 06/18/2023]
Abstract
Using force myography (FMG) to monitor volumetric changes in limb muscles is a promising and effective alternative for controlling bio-robotic prosthetic devices. In recent years, there has been a focus on developing new methods to improve the performance of FMG technology in the control of bio-robotic devices. This study aimed to design and evaluate a novel low-density FMG (LD-FMG) armband for controlling upper limb prostheses. The study investigated the number of sensors and sampling rate for the newly developed LD-FMG band. The performance of the band was evaluated by detecting nine gestures of the hand, wrist, and forearm at varying elbow and shoulder positions. Six subjects, including both fit and amputated individuals, participated in this study and completed two experimental protocols: static and dynamic. The static protocol measured volumetric changes in forearm muscles at the fixed elbow and shoulder positions. In contrast, the dynamic protocol included continuous motion of the elbow and shoulder joints. The results showed that the number of sensors significantly impacts gesture prediction accuracy, with the best accuracy achieved on the 7-sensor FMG band arrangement. Compared to the number of sensors, the sampling rate had a lower influence on prediction accuracy. Additionally, variations in limb position greatly affect the classification accuracy of gestures. The static protocol shows an accuracy above 90% when considering nine gestures. Among dynamic results, shoulder movement shows the least classification error compared to elbow and elbow-shoulder (ES) movements.
Collapse
Affiliation(s)
- Mustafa Ur Rehman
- Department of Mechatronics Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan
| | - Kamran Shah
- Department of Mechatronics Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan
- Department of Mechanical Engineering, King Faisal University, Al-Hofuf 31982, Saudi Arabia
| | - Izhar Ul Haq
- Department of Mechatronics Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan
| | - Sajid Iqbal
- Department of Information Systems, King Faisal University, Al-Hofuf 31982, Saudi Arabia
| | - Mohamed A. Ismail
- Department of Mechanical Engineering, King Faisal University, Al-Hofuf 31982, Saudi Arabia
| | - Fatih Selimefendigil
- Department of Mechanical Engineering, King Faisal University, Al-Hofuf 31982, Saudi Arabia
| |
Collapse
|
15
|
Xue X, Zhang B, Moon S, Xu GX, Huang CC, Sharma N, Jiang X. Development of a Wearable Ultrasound Transducer for Sensing Muscle Activities in Assistive Robotics Applications. BIOSENSORS 2023; 13:134. [PMID: 36671969 PMCID: PMC9855872 DOI: 10.3390/bios13010134] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 01/05/2023] [Accepted: 01/08/2023] [Indexed: 06/17/2023]
Abstract
Robotic prostheses and powered exoskeletons are novel assistive robotic devices for modern medicine. Muscle activity sensing plays an important role in controlling assistive robotics devices. Most devices measure the surface electromyography (sEMG) signal for myoelectric control. However, sEMG is an integrated signal from muscle activities. It is difficult to sense muscle movements in specific small regions, particularly at different depths. Alternatively, traditional ultrasound imaging has recently been proposed to monitor muscle activity due to its ability to directly visualize superficial and at-depth muscles. Despite their advantages, traditional ultrasound probes lack wearability. In this paper, a wearable ultrasound (US) transducer, based on lead zirconate titanate (PZT) and a polyimide substrate, was developed for a muscle activity sensing demonstration. The fabricated PZT-5A elements were arranged into a 4 × 4 array and then packaged in polydimethylsiloxane (PDMS). In vitro porcine tissue experiments were carried out by generating the muscle activities artificially, and the muscle movements were detected by the proposed wearable US transducer via muscle movement imaging. Experimental results showed that all 16 elements had very similar acoustic behaviors: the averaged central frequency, -6 dB bandwidth, and electrical impedance in water were 10.59 MHz, 37.69%, and 78.41 Ω, respectively. The in vitro study successfully demonstrated the capability of monitoring local muscle activity using the prototyped wearable transducer. The findings indicate that ultrasonic sensing may be an alternative to standardize myoelectric control for assistive robotics applications.
Collapse
Affiliation(s)
- Xiangming Xue
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA
| | - Bohua Zhang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA
| | - Sunho Moon
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA
| | - Guo-Xuan Xu
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
| | - Chih-Chung Huang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
| | - Nitin Sharma
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA
| | - Xiaoning Jiang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|
16
|
Centracchio J, Esposito D, Gargiulo GD, Andreozzi E. Changes in Forcecardiography Heartbeat Morphology Induced by Cardio-Respiratory Interactions. SENSORS (BASEL, SWITZERLAND) 2022; 22:9339. [PMID: 36502041 PMCID: PMC9736082 DOI: 10.3390/s22239339] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 11/24/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
The cardiac function is influenced by respiration. In particular, various parameters such as cardiac time intervals and the stroke volume are modulated by respiratory activity. It has long been recognized that cardio-respiratory interactions modify the morphology of cardio-mechanical signals, e.g., phonocardiogram, seismocardiogram (SCG), and ballistocardiogram. Forcecardiography (FCG) records the weak forces induced on the chest wall by the mechanical activity of the heart and lungs and relies on specific force sensors that are capable of monitoring respiration, infrasonic cardiac vibrations, and heart sounds, all simultaneously from a single site on the chest. This study addressed the changes in FCG heartbeat morphology caused by respiration. Two respiratory-modulated parameters were considered, namely the left ventricular ejection time (LVET) and a morphological similarity index (MSi) between heartbeats. The time trends of these parameters were extracted from FCG signals and further analyzed to evaluate their consistency within the respiratory cycle in order to assess their relationship with the breathing activity. The respiratory acts were localized in the time trends of the LVET and MSi and compared with a reference respiratory signal by computing the sensitivity and positive predictive value (PPV). In addition, the agreement between the inter-breath intervals estimated from the LVET and MSi and those estimated from the reference respiratory signal was assessed via linear regression and Bland-Altman analyses. The results of this study clearly showed a tight relationship between the respiratory activity and the considered respiratory-modulated parameters. Both the LVET and MSi exhibited cyclic time trends that remarkably matched the reference respiratory signal. In addition, they achieved a very high sensitivity and PPV (LVET: 94.7% and 95.7%, respectively; MSi: 99.3% and 95.3%, respectively). The linear regression analysis reported almost unit slopes for both the LVET (R2 = 0.86) and MSi (R2 = 0.97); the Bland-Altman analysis reported a non-significant bias for both the LVET and MSi as well as limits of agreement of ±1.68 s and ±0.771 s, respectively. In summary, the results obtained were substantially in line with previous findings on SCG signals, adding to the evidence that FCG and SCG signals share a similar information content.
Collapse
Affiliation(s)
- Jessica Centracchio
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio 21, 80125 Napoli, Italy
| | - Daniele Esposito
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio 21, 80125 Napoli, Italy
| | - Gaetano D. Gargiulo
- School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW 2751, Australia
| | - Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio 21, 80125 Napoli, Italy
| |
Collapse
|
17
|
Liu C, Li J, Zhang S, Yang H, Guo K. Study on Flexible sEMG Acquisition System and Its Application in Muscle Strength Evaluation and Hand Rehabilitation. MICROMACHINES 2022; 13:2047. [PMID: 36557346 PMCID: PMC9782516 DOI: 10.3390/mi13122047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Revised: 11/18/2022] [Accepted: 11/20/2022] [Indexed: 06/01/2023]
Abstract
Wearable devices based on surface electromyography (sEMG) to detect muscle activity can be used to assess muscle strength with the development of hand rehabilitation applications. However, conventional acquisition devices are usually complicated to operate and poorly comfortable for more medical and scientific application scenarios. Here, we report a flexible sEMG acquisition system that combines a graphene-based flexible electrode with a signal acquisition flexible printed circuit (FPC) board. Our system utilizes a polydimethylsiloxane (PDMS) substrate combined with graphene transfer technology to develop a flexible sEMG sensor. The single-lead sEMG acquisition system was designed and the FPC board was fabricated considering the requirements of flexible bending and twisting. We demonstrate the above design approach and extend this flexible sEMG acquisition system to applications for assessing muscle strength and hand rehabilitation training using a long- and short-term memory network training model trained to predict muscle strength, with 98.81% accuracy in the test set. The device exhibited good flexion and comfort characteristics. In general, the ability to accurately and imperceptibly monitor surface electromyography (EMG) signals is critical for medical professionals and patients.
Collapse
Affiliation(s)
- Chang Liu
- College of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130022, China
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Jiuqiang Li
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
| | - Senhao Zhang
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
| | - Hongbo Yang
- College of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130022, China
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
| | - Kai Guo
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
| |
Collapse
|
18
|
Wang H, Zuo S, Cerezo-Sánchez M, Arekhloo NG, Nazarpour K, Heidari H. Wearable super-resolution muscle-machine interfacing. Front Neurosci 2022; 16:1020546. [PMID: 36466163 PMCID: PMC9714306 DOI: 10.3389/fnins.2022.1020546] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 10/21/2022] [Indexed: 09/19/2023] Open
Abstract
Muscles are the actuators of all human actions, from daily work and life to communication and expression of emotions. Myography records the signals from muscle activities as an interface between machine hardware and human wetware, granting direct and natural control of our electronic peripherals. Regardless of the significant progression as of late, the conventional myographic sensors are still incapable of achieving the desired high-resolution and non-invasive recording. This paper presents a critical review of state-of-the-art wearable sensing technologies that measure deeper muscle activity with high spatial resolution, so-called super-resolution. This paper classifies these myographic sensors according to the different signal types (i.e., biomechanical, biochemical, and bioelectrical) they record during measuring muscle activity. By describing the characteristics and current developments with advantages and limitations of each myographic sensor, their capabilities are investigated as a super-resolution myography technique, including: (i) non-invasive and high-density designs of the sensing units and their vulnerability to interferences, (ii) limit-of-detection to register the activity of deep muscles. Finally, this paper concludes with new opportunities in this fast-growing super-resolution myography field and proposes promising future research directions. These advances will enable next-generation muscle-machine interfaces to meet the practical design needs in real-life for healthcare technologies, assistive/rehabilitation robotics, and human augmentation with extended reality.
Collapse
Affiliation(s)
- Huxi Wang
- Microelectronics Lab, James Watt School of Engineering, The University of Glasgow, Glasgow, United Kingdom
- Neuranics Ltd., Glasgow, United Kingdom
| | - Siming Zuo
- Microelectronics Lab, James Watt School of Engineering, The University of Glasgow, Glasgow, United Kingdom
- Neuranics Ltd., Glasgow, United Kingdom
| | - María Cerezo-Sánchez
- Microelectronics Lab, James Watt School of Engineering, The University of Glasgow, Glasgow, United Kingdom
- Neuranics Ltd., Glasgow, United Kingdom
| | - Negin Ghahremani Arekhloo
- Microelectronics Lab, James Watt School of Engineering, The University of Glasgow, Glasgow, United Kingdom
- Neuranics Ltd., Glasgow, United Kingdom
| | - Kianoush Nazarpour
- Neuranics Ltd., Glasgow, United Kingdom
- School of Informatics, The University of Edinburgh, Edinburgh, United Kingdom
| | - Hadi Heidari
- Microelectronics Lab, James Watt School of Engineering, The University of Glasgow, Glasgow, United Kingdom
- Neuranics Ltd., Glasgow, United Kingdom
| |
Collapse
|
19
|
Bouyam C, Punsawad Y. Human–machine interface-based wheelchair control using piezoelectric sensors based on face and tongue movements. Heliyon 2022; 8:e11679. [DOI: 10.1016/j.heliyon.2022.e11679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 08/29/2022] [Accepted: 11/10/2022] [Indexed: 11/20/2022] Open
|
20
|
Andreozzi E, Sabbadini R, Centracchio J, Bifulco P, Irace A, Breglio G, Riccio M. Multimodal Finger Pulse Wave Sensing: Comparison of Forcecardiography and Photoplethysmography Sensors. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22197566. [PMID: 36236663 PMCID: PMC9570799 DOI: 10.3390/s22197566] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 09/26/2022] [Accepted: 10/01/2022] [Indexed: 05/31/2023]
Abstract
Pulse waves (PWs) are mechanical waves that propagate from the ventricles through the whole vascular system as brisk enlargements of the blood vessels' lumens, caused by sudden increases in local blood pressure. Photoplethysmography (PPG) is one of the most widespread techniques employed for PW sensing due to its ability to measure blood oxygen saturation. Other sensors and techniques have been proposed to record PWs, and include applanation tonometers, piezoelectric sensors, force sensors of different kinds, and accelerometers. The performances of these sensors have been analyzed individually, and their results have been found not to be in good agreement (e.g., in terms of PW morphology and the physiological parameters extracted). Such a comparison has led to a deeper comprehension of their strengths and weaknesses, and ultimately, to the consideration that a multimodal approach accomplished via sensor fusion would lead to a more robust, reliable, and potentially more informative methodology for PW monitoring. However, apart from various multichannel and multi-site systems proposed in the literature, no true multimodal sensors for PW recording have been proposed yet that acquire PW signals simultaneously from the same measurement site. In this study, a true multimodal PW sensor is presented, which was obtained by integrating a piezoelectric forcecardiography (FCG) sensor and a PPG sensor, thus enabling simultaneous mechanical-optical measurements of PWs from the same site on the body. The novel sensor performance was assessed by measuring the finger PWs of five healthy subjects at rest. The preliminary results of this study showed, for the first time, that a delay exists between the PWs recorded simultaneously by the PPG and FCG sensors. Despite such a delay, the pulse waveforms acquired by the PPG and FCG sensors, along with their first and second derivatives, had very high normalized cross-correlation indices in excess of 0.98. Six well-established morphological parameters of the PWs were compared via linear regression, correlation, and Bland-Altman analyses, which showed that some of these parameters were not in good agreement for all subjects. The preliminary results of this proof-of-concept study must be confirmed in a much larger cohort of subjects. Further investigation is also necessary to shed light on the physical origin of the observed delay between optical and mechanical PW signals. This research paves the way for the development of true multimodal, wearable, integrated sensors and for potential sensor fusion approaches to improve the performance of PW monitoring at various body sites.
Collapse
|
21
|
Centracchio J, Andreozzi E, Esposito D, Gargiulo GD. Respiratory-Induced Amplitude Modulation of Forcecardiography Signals. Bioengineering (Basel) 2022; 9:bioengineering9090444. [PMID: 36134993 PMCID: PMC9495917 DOI: 10.3390/bioengineering9090444] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 08/25/2022] [Accepted: 09/05/2022] [Indexed: 11/16/2022] Open
Abstract
Forcecardiography (FCG) is a novel technique that records the weak forces induced on the chest wall by cardio-respiratory activity, by using specific force sensors. FCG sensors feature a wide frequency band, which allows us to capture respiration, heart wall motion, heart valves opening and closing (similar to the Seismocardiogram, SCG) and heart sounds, all simultaneously from a single contact point on the chest. As a result, the raw FCG sensors signals exhibit a large component related to the respiratory activity, referred to as a Forcerespirogram (FRG), with a much smaller, superimposed component related to the cardiac activity (the actual FCG) that contains both infrasonic vibrations, referred to as LF-FCG and HF-FCG, and heart sounds. Although respiration can be readily monitored by extracting the very low-frequency component of the raw FCG signal (FRG), it has been observed that the respiratory activity also influences other FCG components, particularly causing amplitude modulations (AM). This preliminary study aimed to assess the consistency of the amplitude modulations of the LF-FCG and HF-FCG signals within the respiratory cycle. A retrospective analysis was performed on the FCG signals acquired in a previous study on six healthy subjects at rest, during quiet breathing. To this aim, the AM of LF-FCG and HF-FCG were first extracted via a linear envelope (LE) operation, consisting of rectification followed by low-pass filtering; then, the inspiratory peaks were located both in the LE of LF-FCG and HF-FCG, and in the reference respiratory signal (FRG). Finally, the inter-breath intervals were extracted from the obtained inspiratory peaks, and further analyzed via statistical analyses. The AM of HF-FCG exhibited higher consistency within the respiratory cycle, as compared to the LF-FCG. Indeed, the inspiratory peaks were recognized with a sensitivity and positive predictive value (PPV) in excess of 99% in the LE of HF-FCG, and with a sensitivity and PPV of 96.7% and 92.6%, respectively, in the LE of LF-FCG. In addition, the inter-breath intervals estimated from the HF-FCG scored a higher R2 value (0.95 vs. 0.86) and lower limits of agreement (± 0.710 s vs. ±1.34 s) as compared to LF-FCG, by considering those extracted from the FRG as the reference. The obtained results are consistent with those observed in previous studies on SCG. A possible explanation of these results was discussed. However, the preliminary results obtained in this study must be confirmed on a larger cohort of subjects and in different experimental conditions.
Collapse
Affiliation(s)
- Jessica Centracchio
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 80125 Napoli, Italy
| | - Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 80125 Napoli, Italy
- Correspondence:
| | - Daniele Esposito
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 80125 Napoli, Italy
| | - Gaetano D. Gargiulo
- School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW 2751, Australia
| |
Collapse
|
22
|
Zhang H, Wang X, Zhang Y, Cao G, Xia C. Design on a wireless mechanomyography acquisition equipment and feature selection for lower limb motion recognition. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
23
|
Asghar A, Jawaid Khan S, Azim F, Shakeel CS, Hussain A, Niazi IK. Review on electromyography based intention for upper limb control using pattern recognition for human-machine interaction. Proc Inst Mech Eng H 2022; 236:628-645. [DOI: 10.1177/09544119221074770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Upper limb myoelectric prosthetic control is an essential topic in the field of rehabilitation. The technique controls prostheses using surface electromyogram (sEMG) and intramuscular EMG (iEMG) signals. EMG signals are extensively used in controlling prosthetic upper and lower limbs, virtual reality entertainment, and human-machine interface (HMI). EMG signals are vital parameters for machine learning and deep learning algorithms and help to give an insight into the human brain’s function and mechanisms. Pattern recognition techniques pertaining to support vector machine (SVM), k-nearest neighbor (KNN) and Bayesian classifiers have been utilized to classify EMG signals. This paper presents a review on current EMG signal techniques, including electrode array utilization, signal acquisition, signal preprocessing and post-processing, feature selection and extraction, data dimensionality reduction, classification, and ultimate application to the community. The paper also discusses using alternatives to EMG signals, such as force sensors, to measure muscle activity with reliable results. Future implications for EMG classification include employing deep learning techniques such as artificial neural networks (ANN) and recurrent neural networks (RNN) for achieving robust results.
Collapse
Affiliation(s)
- Ali Asghar
- Department of Biomedical Engineering, Faculty of Engineering, Science, Technology and Management, Ziauddin University, Karachi, Pakistan
- Department of Electrical Engineering, Faculty of Engineering, Science, Technology and Management, Ziauddin University, Karachi, Pakistan
| | - Saad Jawaid Khan
- Department of Biomedical Engineering, Faculty of Engineering, Science, Technology and Management, Ziauddin University, Karachi, Pakistan
| | - Fahad Azim
- Department of Electrical Engineering, Faculty of Engineering, Science, Technology and Management, Ziauddin University, Karachi, Pakistan
| | - Choudhary Sobhan Shakeel
- Department of Biomedical Engineering, Faculty of Engineering, Science, Technology and Management, Ziauddin University, Karachi, Pakistan
| | - Amatullah Hussain
- College of Rehabilitation Sciences, Ziauddin University, Karachi, Pakistan
| | - Imran Khan Niazi
- Centre for Chiropractic Research, New Zealand College of Chiropractic, New Zealand
- Faculty of Health & Environmental Sciences, Health & Rehabilitation Research Institute, AUT University, New Zealand
- Centre for Sensory-Motor Interactions, Department of Health Science and Technology, Aalborg University, Denmark
| |
Collapse
|
24
|
Myoelectric Pattern Recognition Performance Enhancement Using Nonlinear Features. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE 2022; 2022:6414664. [PMID: 35528339 PMCID: PMC9076314 DOI: 10.1155/2022/6414664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 04/07/2022] [Accepted: 04/11/2022] [Indexed: 11/17/2022]
Abstract
The multichannel electrode array used for electromyogram (EMG) pattern recognition provides good performance, but it has a high cost, is computationally expensive, and is inconvenient to wear. Therefore, researchers try to use as few channels as possible while maintaining improved pattern recognition performance. However, minimizing the number of channels affects the performance due to the least separable margin among the movements possessing weak signal strengths. To meet these challenges, two time-domain features based on nonlinear scaling, the log of the mean absolute value (LMAV) and the nonlinear scaled value (NSV), are proposed. In this study, we validate the proposed features on two datasets, the existing four feature extraction methods, variable window size, and various signal-to-noise ratios (SNR). In addition, we also propose a feature extraction method where the LMAV and NSV are grouped with the existing 11 time-domain features. The proposed feature extraction method enhances accuracy, sensitivity, specificity, precision, and F1 score by 1.00%, 5.01%, 0.55%, 4.71%, and 5.06% for dataset 1, and 1.18%, 5.90%, 0.66%, 5.63%, and 6.04% for dataset 2, respectively. Therefore, the experimental results strongly suggest the proposed feature extraction method, for taking a step forward with regard to improved myoelectric pattern recognition performance.
Collapse
|
25
|
Human Joint Torque Estimation Based on Mechanomyography for Upper Extremity Exosuit. ELECTRONICS 2022. [DOI: 10.3390/electronics11091335] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
Human intention recognition belongs to the algorithm basis for exoskeleton robots to generate synergic movements and provide corresponding assistance. In this article, we acquire and analyze the mechanomyography (MMG) to estimate the current joint torque and apply this method to the rehabilitation training research of the upper extremity exosuit. In order to obtain relatively pure biological signals, a MMG processing method based on the Hilbert-Huang Transform (HHT) is proposed to eliminate the mixed noise and motion artifacts. After extracting features and forming the dataset, a random forest regression (RFR) model is designed to build the mapping relationship between MMG and human joint output through offline learning. In addition, an upper extremity exosuit is constructed for multi-joint assistance. Based on the above research, we develop a torque estimation-based control strategy and make it responsible for the intention understanding and motion servo of this customized system. Finally, an actual test verifies the accuracy and reliability of this recognition algorithm, and an efficiency evaluation experiment also proves the feasibility for power assistance.
Collapse
|
26
|
Andreozzi E, Centracchio J, Esposito D, Bifulco P. A Comparison of Heart Pulsations Provided by Forcecardiography and Double Integration of Seismocardiogram. Bioengineering (Basel) 2022; 9:bioengineering9040167. [PMID: 35447727 PMCID: PMC9029002 DOI: 10.3390/bioengineering9040167] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 04/06/2022] [Accepted: 04/07/2022] [Indexed: 11/16/2022] Open
Abstract
Seismocardiography (SCG) is largely regarded as the state-of-the-art technique for continuous, long-term monitoring of cardiac mechanical activity in wearable applications. SCG signals are acquired via small, lightweight accelerometers fixed on the chest. They provide timings of important cardiac events, such as heart valves openings and closures, thus allowing the estimation of cardiac time intervals of clinical relevance. Forcecardiography (FCG) is a novel technique that records the cardiac-induced vibrations of the chest wall by means of specific force sensors, which proved capable of monitoring respiration, heart sounds and infrasonic cardiac vibrations, simultaneously from a single contact point on the chest. A specific infrasonic component captures the heart walls displacements and looks very similar to the Apexcardiogram. This low-frequency component is not visible in SCG recordings, nor it can be extracted by simple filtering. In this study, a feasible way to extract this information from SCG signals is presented. The proposed approach is based on double integration of SCG. Numerical double integration is usually very prone to large errors, therefore a specific numerical procedure was devised. This procedure yields a new displacement signal (DSCG) that features a low-frequency component (LF-DSCG) very similar to that of the FCG (LF-FCG). Experimental tests were carried out using an FCG sensor and an off-the-shelf accelerometer firmly attached to each other and placed onto the precordial region. Simultaneous recordings were acquired from both sensors, together with an electrocardiogram lead (used as a reference). Quantitative morphological comparison confirmed the high similarity between LF-FCG and LF-DSCG (normalized cross-correlation index >0.9). Statistical analyses suggested that LF-DSCG, although achieving a fair sensitivity in heartbeat detection (about 90%), has not a very high consistency within the cardiac cycle, leading to inaccuracies in inter-beat intervals estimation. Future experiments with high-performance accelerometers and improved processing methods are envisioned to investigate the potential enhancement of the accuracy and reliability of the proposed method.
Collapse
|
27
|
Shah J, Quinkert C, Collar B, Williams M, Biggs E, Irazoqui P. A Highly Miniaturized, Chronically Implanted ASIC for Electrical Nerve Stimulation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:233-243. [PMID: 35201991 PMCID: PMC9195150 DOI: 10.1109/tbcas.2022.3153282] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We present a wireless, fully implantable device for electrical stimulation of peripheral nerves consisting of a powering coil, a tuning network, a Zener diode, selectable stimulation parameters, and a stimulator IC, all encapsulated in biocompatible silicone. A wireless RF signal at 13.56 MHz powers the implant through the on-chip rectifier. The ASIC, designed in TSMC's 180 nm MS RF G process, occupies an area of less than 1.2 mm2. The IC enables externally selectable current-controlled stimulation through an on-chip read-only memory with a wide range of 32 stimulation parameters (90-750 µA amplitude, 100 µs or 1 ms pulse width, 15 or 50 Hz frequency). The IC generates the constant current waveform using an 8-bit binary weighted DAC and an H-Bridge. At the most power-hungry stimulation parameter, the average power consumption during a stimulus pulse is 2.6 mW with a power transfer efficiency of ∼5.2%. In addition to benchtop and acute testing, we chronically implanted two versions of the device (a design with leads and a leadless design) on two rats' sciatic nerves to verify the long-term efficacy of the IC and the full system. The leadless device had the following dimensions: height of 0.45 cm, major axis of 1.85 cm, and minor axis of 1.34 cm, with similar dimensions for the device with leads. Both devices were implanted and worked for experiments lasting from 21-90 days. To the best of our knowledge, the fabricated IC is the smallest constant-current stimulator that has been tested chronically.
Collapse
|
28
|
Centracchio J, Andreozzi E, Esposito D, Gargiulo GD, Bifulco P. Detection of Aortic Valve Opening and Estimation of Pre-Ejection Period in Forcecardiography Recordings. Bioengineering (Basel) 2022; 9:bioengineering9030089. [PMID: 35324778 PMCID: PMC8945374 DOI: 10.3390/bioengineering9030089] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 02/14/2022] [Accepted: 02/18/2022] [Indexed: 11/16/2022] Open
Abstract
Forcecardiography (FCG) is a novel technique that measures the local forces induced on the chest wall by the mechanical activity of the heart. Specific piezoresistive or piezoelectric force sensors are placed on subjects’ thorax to measure these very small forces. The FCG signal can be divided into three components: low-frequency FCG, high-frequency FCG (HF-FCG) and heart sound FCG. HF-FCG has been shown to share a high similarity with the Seismocardiogram (SCG), which is commonly acquired via small accelerometers and is mainly used to locate specific fiducial markers corresponding to essential events of the cardiac cycle (e.g., heart valves opening and closure, peaks of blood flow). However, HF-FCG has not yet been demonstrated to provide the timings of these markers with reasonable accuracy. This study addresses the detection of the aortic valve opening (AO) marker in FCG signals. To this aim, simultaneous recordings from FCG and SCG sensors were acquired, together with Electrocardiogram (ECG) recordings, from a few healthy subjects at rest, both during quiet breathing and apnea. The AO markers were located in both SCG and FCG signals to obtain pre-ejection periods (PEP) estimates, which were compared via statistical analyses. The PEPs estimated from FCG and SCG showed a strong linear relationship (r > 0.95) with a practically unit slope, and 95% of their differences were found to be distributed within ± 4.6 ms around small biases of approximately 1 ms, corresponding to percentage differences lower than 5% of the mean measured PEP. These preliminary results suggest that FCG can provide accurate AO timings and PEP estimates.
Collapse
Affiliation(s)
- Jessica Centracchio
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy; (J.C.); (D.E.); (P.B.)
| | - Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy; (J.C.); (D.E.); (P.B.)
- Correspondence:
| | - Daniele Esposito
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy; (J.C.); (D.E.); (P.B.)
| | - Gaetano Dario Gargiulo
- School of Engineering, Design and Built Environment, Western Sydney University, Penrith 2751, Australia;
| | - Paolo Bifulco
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy; (J.C.); (D.E.); (P.B.)
| |
Collapse
|
29
|
Design of a 3D-Printed Hand Exoskeleton Based on Force-Myography Control for Assistance and Rehabilitation. MACHINES 2022. [DOI: 10.3390/machines10010057] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Voluntary hand movements are usually impaired after a cerebral stroke, affecting millions of people per year worldwide. Recently, the use of hand exoskeletons for assistance and motor rehabilitation has become increasingly widespread. This study presents a novel hand exoskeleton, designed to be low cost, wearable, easily adaptable and suitable for home use. Most of the components of the exoskeleton are 3D printed, allowing for easy replication, customization and maintenance at a low cost. A strongly underactuated mechanical system allows one to synergically move the four fingers by means of a single actuator through a rigid transmission, while the thumb is kept in an adduction or abduction position. The exoskeleton’s ability to extend a typical hypertonic paretic hand of stroke patients was firstly tested using the SimScape Multibody simulation environment; this helped in the choice of a proper electric actuator. Force-myography was used instead of the standard electromyography to voluntarily control the exoskeleton with more simplicity. The user can activate the flexion/extension of the exoskeleton by a weak contraction of two antagonist muscles. A symmetrical master–slave motion strategy (i.e., the paretic hand motion is activated by the healthy hand) is also available for patients with severe muscle atrophy. An inexpensive microcontroller board was used to implement the electronic control of the exoskeleton and provide feedback to the user. The entire exoskeleton including batteries can be worn on the patient’s arm. The ability to provide a fluid and safe grip, like that of a healthy hand, was verified through kinematic analyses obtained by processing high-framerate videos. The trajectories described by the phalanges of the natural and the exoskeleton finger were compared by means of cross-correlation coefficients; a similarity of about 80% was found. The time required for both closing and opening of the hand exoskeleton was about 0.9 s. A rigid cylindric handlebar containing a load cell measured an average power grasp force of 94.61 N, enough to assist the user in performing most of the activities of daily living. The exoskeleton can be used as an aid and to promote motor function recovery during patient’s neurorehabilitation therapy.
Collapse
|
30
|
Basic characteristics between mechanomyogram and muscle force during twitch and tetanic contractions in rat skeletal muscles. J Electromyogr Kinesiol 2022; 62:102627. [PMID: 34999536 DOI: 10.1016/j.jelekin.2021.102627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 11/18/2021] [Accepted: 12/29/2021] [Indexed: 11/21/2022] Open
Abstract
The mechanomyogram (MMG) is a signal measured by various vibration sensors for slight vibrations induced by muscle contraction, and it reflects the muscle force during electrically induced-contraction or until 60%-70% maximum voluntary contraction, so the MMG is considered an alternative and novel measurement tool for muscle strength. We simultaneously measured the MMG and muscle force in the gastrocnemius (GC), vastus intermedius (VI), and soleus (SOL) muscles of rats. The muscle force was measured by attaching a hook to the tendon using a load cell, and the MMG was measured using a charged-coupled device-type displacement sensor at the middle of the target muscle. The MMG-twitch waveform was very similar to that of the muscle force; however, the half relaxation time and relaxation time (10%), which are relaxation parameters, were prolonged compared to those of the muscle force. The MMG amplitude correlated with the muscle force. Since stimulation frequencies that are necessary to evoke tetanic progression have a significant correlation with the twitch parameter, there is a close relationship between twitch and tetanus in the MMG signal. Therefore, we suggest that the MMG, which is electrically induced and detected by a laser displacement sensor, may be an alternative tool for measuring muscle strength.
Collapse
|
31
|
Sobh KNM, Razak NAA, Osman NAA. A FSR Sensor Cuff to Measure Muscle Activation During Strength and Gait Cycle for Lower Limb. IEEE ACCESS 2022; 10:106135-106147. [DOI: 10.1109/access.2022.3207497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Affiliation(s)
- Khaled Nedal Mahmoud Sobh
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Nasrul Anuar Abd Razak
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Noor Azuan Abu Osman
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
32
|
Andreozzi E, Gargiulo GD, Esposito D, Bifulco P. A Novel Broadband Forcecardiography Sensor for Simultaneous Monitoring of Respiration, Infrasonic Cardiac Vibrations and Heart Sounds. Front Physiol 2021; 12:725716. [PMID: 34867438 PMCID: PMC8637282 DOI: 10.3389/fphys.2021.725716] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 10/19/2021] [Indexed: 01/14/2023] Open
Abstract
The precordial mechanical vibrations generated by cardiac contractions have a rich frequency spectrum. While the lowest frequencies can be palpated, the higher infrasonic frequencies are usually captured by the seismocardiogram (SCG) signal and the audible ones correspond to heart sounds. Forcecardiography (FCG) is a non-invasive technique that measures these vibrations via force sensing resistors (FSR). This study presents a new piezoelectric sensor able to record all heart vibrations simultaneously, as well as a respiration signal. The new sensor was compared to the FSR-based one to assess its suitability for FCG. An electrocardiogram (ECG) lead and a signal from an electro-resistive respiration band (ERB) were synchronously acquired as references on six healthy volunteers (4 males, 2 females) at rest. The raw signals from the piezoelectric and the FSR-based sensors turned out to be very similar. The raw signals were divided into four components: Forcerespirogram (FRG), Low-Frequency FCG (LF-FCG), High-Frequency FCG (HF-FCG) and heart sounds (HS-FCG). A beat-by-beat comparison of FCG and ECG signals was carried out by means of regression, correlation and Bland–Altman analyses, and similarly for respiration signals (FRG and ERB). The results showed that the infrasonic FCG components are strongly related to the cardiac cycle (R2 > 0.999, null bias and Limits of Agreement (LoA) of ± 4.9 ms for HF-FCG; R2 > 0.99, null bias and LoA of ± 26.9 ms for LF-FCG) and the FRG inter-breath intervals are consistent with ERB ones (R2 > 0.99, non-significant bias and LoA of ± 0.46 s). Furthermore, the piezoelectric sensor was tested against an accelerometer and an electronic stethoscope: synchronous acquisitions were performed to quantify the similarity between the signals. ECG-triggered ensemble averages (synchronized with R-peaks) of HF-FCG and SCG showed a correlation greater than 0.81, while those of HS-FCG and PCG scored a correlation greater than 0.85. The piezoelectric sensor demonstrated superior performances as compared to the FSR, providing more accurate, beat-by-beat measurements. This is the first time that a single piezoelectric sensor demonstrated the ability to simultaneously capture respiration, heart sounds, an SCG-like signal (i.e., HF-FCG) and the LF-FCG signal, which may provide information on ventricular emptying and filling events. According to these preliminary results the novel piezoelectric FCG sensor stands as a promising device for accurate, unobtrusive, long-term monitoring of cardiorespiratory functions and paves the way for a wide range of potential applications, both in the research and clinical fields. However, these results should be confirmed by further analyses on a larger cohort of subjects, possibly including also pathological patients.
Collapse
Affiliation(s)
- Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| | - Gaetano D Gargiulo
- School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW, Australia
| | - Daniele Esposito
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| | - Paolo Bifulco
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Naples, Italy
| |
Collapse
|
33
|
Kett AR, Milani TL, Sichting F. Sitting for Too Long, Moving Too Little: Regular Muscle Contractions Can Reduce Muscle Stiffness During Prolonged Periods of Chair-Sitting. Front Sports Act Living 2021; 3:760533. [PMID: 34805980 PMCID: PMC8595117 DOI: 10.3389/fspor.2021.760533] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 10/11/2021] [Indexed: 12/19/2022] Open
Abstract
In modern Western societies, sedentary behavior has become a growing health concern. There is increasing evidence that prolonged sitting periods can be associated with musculoskeletal disorders. While it is generally recognized that back muscle activity is low during chair-sitting, little is known about the consequences of minor to no muscle activity on muscle stiffness. Muscle stiffness may play an important role in musculoskeletal health. This study investigated the effects of regular muscle contractions on muscle stiffness in a controlled experiment in which participants sat for 4.5 h. Neuromuscular electrical stimulation in the lumbar region of the back was applied to trigger regular muscle contractions. Using stiffness measurements and continuous motion capturing, we found that prolonged sitting periods without regular muscle contractions significantly increased back muscle stiffness. Moreover, we were able to show that regular muscle contractions can prevent those effects. Our results highlight the importance of consistent muscle activity throughout the day and may help explain why prolonged periods of chair-sitting increase the susceptibility to common pathological conditions such as low back pain.
Collapse
Affiliation(s)
- Alexander R Kett
- Department of Human Locomotion, Institute of Human Movement Science and Health, Chemnitz University of Technology, Chemnitz, Germany.,Research & Development, Mercedes-Benz AG, Böblingen, Germany
| | - Thomas L Milani
- Department of Human Locomotion, Institute of Human Movement Science and Health, Chemnitz University of Technology, Chemnitz, Germany
| | - Freddy Sichting
- Department of Human Locomotion, Institute of Human Movement Science and Health, Chemnitz University of Technology, Chemnitz, Germany
| |
Collapse
|
34
|
Wearable Bluetooth Triage Healthcare Monitoring System. SENSORS 2021; 21:s21227586. [PMID: 34833659 PMCID: PMC8619240 DOI: 10.3390/s21227586] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 11/09/2021] [Accepted: 11/11/2021] [Indexed: 11/17/2022]
Abstract
Triage is the first interaction between a patient and a nurse/paramedic. This assessment, usually performed at Emergency departments, is a highly dynamic process and there are international grading systems that according to the patient condition initiate the patient journey. Triage requires an initial rapid assessment followed by routine checks of the patients’ vitals, including respiratory rate, temperature, and pulse rate. Ideally, these checks should be performed continuously and remotely to reduce the workload on triage nurses; optimizing tools and monitoring systems can be introduced and include a wearable patient monitoring system that is not at the expense of the patient’s comfort and can be remotely monitored through wireless connectivity. In this study, we assessed the suitability of a small ceramic piezoelectric disk submerged in a skin-safe silicone dome that enhances contact with skin, to detect wirelessly both respiration and cardiac events at several positions on the human body. For the purposes of this evaluation, we fitted the sensor with a respiratory belt as well as a single lead ECG, all acquired simultaneously. To complete Triage parameter collection, we also included a medical-grade contact thermometer. Performances of cardiac and respiratory events detection were assessed. The instantaneous heart and respiratory rates provided by the proposed sensor, the ECG and the respiratory belt were compared via statistical analyses. In all considered sensor positions, very high performances were achieved for the detection of both cardiac and respiratory events, except for the wrist, which provided lower performances for respiratory rates. These promising yet preliminary results suggest the proposed wireless sensor could be used as a wearable, hands-free monitoring device for triage assessment within emergency departments. Further tests are foreseen to assess sensor performances in real operating environments.
Collapse
|
35
|
A Power-Efficient Sensing Approach for Pulse Wave Palpation-Based Heart Rate Measurement. SENSORS 2021; 21:s21227549. [PMID: 34833626 PMCID: PMC8623446 DOI: 10.3390/s21227549] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 10/28/2021] [Accepted: 11/10/2021] [Indexed: 11/20/2022]
Abstract
Heart rate (HR) is an essential indicator of health in the human body. It measures the number of times per minute that the heart contracts or beats. An irregular heartbeat can signify a severe health condition, so monitoring heart rate periodically can help prevent heart complications. This paper presents a novel wearable sensing approach for remote HR measurement by a compact resistance-to-microcontroller interface circuit. A heartbeat’s signal can be detected by a Force Sensing Resistor (FSR) attached to the body near large arteries (such as the carotid or radial), which expand their area each time the heart expels blood to the body. Depending on how the sensor interfaces with the subject, the FSR changes its electrical resistance every time a pulse is detected. By placing the FSR in a direct interface circuit, those resistance variations can be measured directly by a microcontroller without using either analog processing stages or an analog-to-digital converter. In this kind of interface, the self-heating of the sensor is avoided, since the FSR does not require any voltage or bias current. The proposed system has a sampling rate of 50 Sa/s, and an effective resolution of 10 bits (200 mΩ), enough for obtaining well-shaped cardiac signals and heart rate estimations in real time by the microcontroller. With this approach, the implementation of wearable systems in health monitoring applications is more feasible.
Collapse
|
36
|
Batista E, Moncusi MA, López-Aguilar P, Martínez-Ballesté A, Solanas A. Sensors for Context-Aware Smart Healthcare: A Security Perspective. SENSORS (BASEL, SWITZERLAND) 2021; 21:6886. [PMID: 34696099 PMCID: PMC8537585 DOI: 10.3390/s21206886] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 10/12/2021] [Accepted: 10/14/2021] [Indexed: 12/24/2022]
Abstract
The advances in the miniaturisation of electronic devices and the deployment of cheaper and faster data networks have propelled environments augmented with contextual and real-time information, such as smart homes and smart cities. These context-aware environments have opened the door to numerous opportunities for providing added-value, accurate and personalised services to citizens. In particular, smart healthcare, regarded as the natural evolution of electronic health and mobile health, contributes to enhance medical services and people's welfare, while shortening waiting times and decreasing healthcare expenditure. However, the large number, variety and complexity of devices and systems involved in smart health systems involve a number of challenging considerations to be considered, particularly from security and privacy perspectives. To this aim, this article provides a thorough technical review on the deployment of secure smart health services, ranging from the very collection of sensors data (either related to the medical conditions of individuals or to their immediate context), the transmission of these data through wireless communication networks, to the final storage and analysis of such information in the appropriate health information systems. As a result, we provide practitioners with a comprehensive overview of the existing vulnerabilities and solutions in the technical side of smart healthcare.
Collapse
Affiliation(s)
- Edgar Batista
- Department of Computer Engineering and Mathematics, Universitat Rovira i Virgili, Av. Països Catalans 26, 43007 Tarragona, Spain; (E.B.); (M.A.M.); (A.M.-B.)
- SIMPPLE S.L., C. Joan Maragall 1A, 43003 Tarragona, Spain
| | - M. Angels Moncusi
- Department of Computer Engineering and Mathematics, Universitat Rovira i Virgili, Av. Països Catalans 26, 43007 Tarragona, Spain; (E.B.); (M.A.M.); (A.M.-B.)
| | - Pablo López-Aguilar
- Anti-Phishing Working Group EU, Av. Diagonal 621–629, 08028 Barcelona, Spain;
| | - Antoni Martínez-Ballesté
- Department of Computer Engineering and Mathematics, Universitat Rovira i Virgili, Av. Països Catalans 26, 43007 Tarragona, Spain; (E.B.); (M.A.M.); (A.M.-B.)
| | - Agusti Solanas
- Department of Computer Engineering and Mathematics, Universitat Rovira i Virgili, Av. Països Catalans 26, 43007 Tarragona, Spain; (E.B.); (M.A.M.); (A.M.-B.)
| |
Collapse
|
37
|
Esposito D, Centracchio J, Andreozzi E, Gargiulo GD, Naik GR, Bifulco P. Biosignal-Based Human-Machine Interfaces for Assistance and Rehabilitation: A Survey. SENSORS 2021; 21:s21206863. [PMID: 34696076 PMCID: PMC8540117 DOI: 10.3390/s21206863] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 09/30/2021] [Accepted: 10/12/2021] [Indexed: 12/03/2022]
Abstract
As a definition, Human–Machine Interface (HMI) enables a person to interact with a device. Starting from elementary equipment, the recent development of novel techniques and unobtrusive devices for biosignals monitoring paved the way for a new class of HMIs, which take such biosignals as inputs to control various applications. The current survey aims to review the large literature of the last two decades regarding biosignal-based HMIs for assistance and rehabilitation to outline state-of-the-art and identify emerging technologies and potential future research trends. PubMed and other databases were surveyed by using specific keywords. The found studies were further screened in three levels (title, abstract, full-text), and eventually, 144 journal papers and 37 conference papers were included. Four macrocategories were considered to classify the different biosignals used for HMI control: biopotential, muscle mechanical motion, body motion, and their combinations (hybrid systems). The HMIs were also classified according to their target application by considering six categories: prosthetic control, robotic control, virtual reality control, gesture recognition, communication, and smart environment control. An ever-growing number of publications has been observed over the last years. Most of the studies (about 67%) pertain to the assistive field, while 20% relate to rehabilitation and 13% to assistance and rehabilitation. A moderate increase can be observed in studies focusing on robotic control, prosthetic control, and gesture recognition in the last decade. In contrast, studies on the other targets experienced only a small increase. Biopotentials are no longer the leading control signals, and the use of muscle mechanical motion signals has experienced a considerable rise, especially in prosthetic control. Hybrid technologies are promising, as they could lead to higher performances. However, they also increase HMIs’ complexity, so their usefulness should be carefully evaluated for the specific application.
Collapse
Affiliation(s)
- Daniele Esposito
- Department of Electrical Engineering and Information Technologies, Polytechnic and Basic Sciences School, University of Naples “Federico II”, 80125 Naples, Italy; (D.E.); (J.C.); (E.A.); (P.B.)
| | - Jessica Centracchio
- Department of Electrical Engineering and Information Technologies, Polytechnic and Basic Sciences School, University of Naples “Federico II”, 80125 Naples, Italy; (D.E.); (J.C.); (E.A.); (P.B.)
| | - Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, Polytechnic and Basic Sciences School, University of Naples “Federico II”, 80125 Naples, Italy; (D.E.); (J.C.); (E.A.); (P.B.)
| | - Gaetano D. Gargiulo
- School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW 2747, Australia;
- The MARCS Institute, Western Sydney University, Penrith, NSW 2751, Australia
| | - Ganesh R. Naik
- School of Engineering, Design and Built Environment, Western Sydney University, Penrith, NSW 2747, Australia;
- The Adelaide Institute for Sleep Health, Flinders University, Bedford Park, SA 5042, Australia
- Correspondence:
| | - Paolo Bifulco
- Department of Electrical Engineering and Information Technologies, Polytechnic and Basic Sciences School, University of Naples “Federico II”, 80125 Naples, Italy; (D.E.); (J.C.); (E.A.); (P.B.)
| |
Collapse
|
38
|
DATSURYOKU Sensor-A Capacitive-Sensor-Based Belt for Predicting Muscle Tension: Preliminary Results. SENSORS 2021; 21:s21196669. [PMID: 34640988 PMCID: PMC8512158 DOI: 10.3390/s21196669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 10/01/2021] [Accepted: 10/03/2021] [Indexed: 11/17/2022]
Abstract
Excessive muscle tension is implicitly caused by inactivity or tension in daily activities, and it results in increased joint stiffness and vibration, and thus, poor performance, failure, and injury in sports. Therefore, the routine measurement of muscle tension is important. However, a co-contraction observed in excessive muscle tension cannot be easily detected because it does not appear in motion owing to the counteracting muscle tension, and it cannot be measured by conventional motion capture systems. Therefore, we focused on the physiological characteristics of muscle, that is, the increase in muscle belly cross-sectional area during activity and softening during relaxation. Furthermore, we measured muscle tension, especially co-contraction and relaxation, using a DATSURYOKU sensor, which measures the circumference of the applied part. The experiments showed high interclass correlation between muscle activities and circumference across maximal voluntary co-contractions of the thigh muscles and squats. Moreover, the circumference sensor can measure passive muscle deformation that does not appear in muscle activities. Therefore, the DATSURYOKU sensor showed the potential to routinely measure muscle tension and relaxation, thus avoiding the risk of failure and injury owing to excessive muscle tension and can contribute to the realization of preemptive medicine by measuring daily changes.
Collapse
|
39
|
He Z, Qi Z, Liu H, Wang K, Roberts L, Liu JZ, Liu Y, Wang SJ, Cook MJ, Simon GP, Qiu L, Li D. Detecting subtle yet fast skeletal muscle contractions with ultrasoft and durable graphene-based cellular materials. Natl Sci Rev 2021; 9:nwab184. [PMID: 35401990 PMCID: PMC8986457 DOI: 10.1093/nsr/nwab184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Accepted: 09/27/2021] [Indexed: 11/23/2022] Open
Abstract
Human bodily movements are primarily controlled by the contractions of skeletal muscles. Unlike joint or skeletal movements that are generally performed in the large displacement range, the contractions of the skeletal muscles that underpin these movements are subtle in intensity yet high in frequency. This subtlety of movement makes it a formidable challenge to develop wearable and durable soft materials to electrically monitor such motions with high fidelity for the purpose of, for example, muscle/neuromuscular disease diagnosis. Here we report that an intrinsically fragile ultralow-density graphene-based cellular monolith sandwiched between silicone rubbers can exhibit a highly effective stress and strain transfer mechanism at its interface with the rubber, with a remarkable improvement in stretchability (>100%). In particular, this hybrid also exhibits a highly sensitive, broadband-frequency electrical response (up to 180 Hz) for a wide range of strains. By correlating the mechanical signal of muscle movements obtained from this hybrid material with electromyography, we demonstrate that the strain sensor based on this hybrid material may provide a new, soft and wearable mechanomyography approach for real-time monitoring of complex neuromuscular–skeletal interactions in a broad range of healthcare and human–machine interface applications. This work also provides a new architecture-enabled functional soft material platform for wearable electronics.
Collapse
Affiliation(s)
- Zijun He
- Department of Chemical Engineering, The University of Melbourne, Melbourne 3010, Australia
- Department of Materials Science and Engineering, Monash University, Melbourne 3800, Australia
| | - Zheng Qi
- Department of Chemical Engineering, Monash University, Melbourne 3800, Australia
| | - Huichao Liu
- State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace Engineering, Xi’an Jiaotong University, Xi’an 710049, China
| | - Kangyan Wang
- Department of Chemical Engineering, The University of Melbourne, Melbourne 3010, Australia
| | - Leslie Roberts
- Neurophysiology Department, Department of Neurology and Neurological Research, St Vincent's Hospital, Melbourne 3065, Australia
- Department of Medicine, St. Vincent's Hospital, University of Melbourne, Melbourne 3010, Australia
| | - Jefferson Z Liu
- Department of Mechanical Engineering, University of Melbourne, Melbourne 3010, Australia
| | - Yilun Liu
- State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace Engineering, Xi’an Jiaotong University, Xi’an 710049, China
| | - Stephen J Wang
- Department of Design, Monash University, Melbourne 3145, Australia
- School of Design, The Hong Kong Polytechnic University, Hong Kong 999077, China
| | - Mark J Cook
- Department of Medicine, St. Vincent's Hospital, University of Melbourne, Melbourne 3010, Australia
| | - George P Simon
- Department of Materials Science and Engineering, Monash University, Melbourne 3800, Australia
| | - Ling Qiu
- Department of Materials Science and Engineering, Monash University, Melbourne 3800, Australia
- Shenzhen Geim Graphene Center, Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
| | - Dan Li
- Department of Chemical Engineering, The University of Melbourne, Melbourne 3010, Australia
- Department of Materials Science and Engineering, Monash University, Melbourne 3800, Australia
| |
Collapse
|
40
|
Esposito D, Savino S, Andreozzi E, Cosenza C, Niola V, Bifulco P. The "Federica" Hand. Bioengineering (Basel) 2021; 8:128. [PMID: 34562951 PMCID: PMC8493631 DOI: 10.3390/bioengineering8090128] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 08/20/2021] [Accepted: 09/16/2021] [Indexed: 11/16/2022] Open
Abstract
Hand prostheses partially restore hand appearance and functionalities. In particular, 3D printers have provided great opportunities by simplifying the manufacturing process and reducing costs. The "Federica" hand is 3D-printed and equipped with a single servomotor, which synergically actuates its five fingers by inextensible tendons; no springs are used for hand opening. A differential mechanical system simultaneously distributes the motor force on each finger in predefined portions. The proportional control of hand closure/opening is achieved by monitoring muscle contraction by means of a thin force sensor, as an alternative to EMG. The electrical current of the servomotor is monitored to provide sensory feedback of the grip force, through a small vibration motor. A simple Arduino board was adopted as the processing unit. A closed-chain, differential mechanism guarantees efficient transfer of mechanical energy and a secure grasp of any object, regardless of its shape and deformability. The force sensor offers some advantages over the EMG: it does not require any electrical contact or signal processing to monitor muscle contraction intensity. The activation speed (about half a second) is high enough to allow the user to grab objects on the fly. The cost of the device is less then 100 USD. The "Federica" hand has proved to be a lightweight, low-cost and extremely efficient prosthesis. It is now available as an open-source project (CAD files and software can be downloaded from a public repository), thus allowing everyone to use the "Federica" hand and customize or improve it.
Collapse
Affiliation(s)
- Daniele Esposito
- Department of Electrical Engineering and Information Technologies, Polytechnic and Basic Sciences School, University of Naples “Federico II”, 80125 Naples, Italy; (E.A.); (P.B.)
- Department of Neurorehabilitation, IRCCS Istituti Clinici Scientifici Maugeri, 27100 Pavia, Italy
| | - Sergio Savino
- Department of Industrial Engineering, Polytechnic and Basic Sciences School, University of Naples “Federico II”, 80125 Naples, Italy; (S.S.); (C.C.); (V.N.)
| | - Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, Polytechnic and Basic Sciences School, University of Naples “Federico II”, 80125 Naples, Italy; (E.A.); (P.B.)
- Department of Neurorehabilitation, IRCCS Istituti Clinici Scientifici Maugeri, 27100 Pavia, Italy
| | - Chiara Cosenza
- Department of Industrial Engineering, Polytechnic and Basic Sciences School, University of Naples “Federico II”, 80125 Naples, Italy; (S.S.); (C.C.); (V.N.)
| | - Vincenzo Niola
- Department of Industrial Engineering, Polytechnic and Basic Sciences School, University of Naples “Federico II”, 80125 Naples, Italy; (S.S.); (C.C.); (V.N.)
| | - Paolo Bifulco
- Department of Electrical Engineering and Information Technologies, Polytechnic and Basic Sciences School, University of Naples “Federico II”, 80125 Naples, Italy; (E.A.); (P.B.)
- Department of Neurorehabilitation, IRCCS Istituti Clinici Scientifici Maugeri, 27100 Pavia, Italy
| |
Collapse
|
41
|
Respiration Monitoring via Forcecardiography Sensors. SENSORS 2021; 21:s21123996. [PMID: 34207899 PMCID: PMC8228286 DOI: 10.3390/s21123996] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 06/04/2021] [Accepted: 06/07/2021] [Indexed: 12/26/2022]
Abstract
In the last few decades, a number of wearable systems for respiration monitoring that help to significantly reduce patients’ discomfort and improve the reliability of measurements have been presented. A recent research trend in biosignal acquisition is focusing on the development of monolithic sensors for monitoring multiple vital signs, which could improve the simultaneous recording of different physiological data. This study presents a performance analysis of respiration monitoring performed via forcecardiography (FCG) sensors, as compared to ECG-derived respiration (EDR) and electroresistive respiration band (ERB), which was assumed as the reference. FCG is a novel technique that records the cardiac-induced vibrations of the chest wall via specific force sensors, which provide seismocardiogram-like information, along with a novel component that seems to be related to the ventricular volume variations. Simultaneous acquisitions were obtained from seven healthy subjects at rest, during both quiet breathing and forced respiration at higher and lower rates. The raw FCG sensor signals featured a large, low-frequency, respiratory component (R-FCG), in addition to the common FCG signal. Statistical analyses of R-FCG, EDR and ERB signals showed that FCG sensors ensure a more sensitive and precise detection of respiratory acts than EDR (sensitivity: 100% vs. 95.8%, positive predictive value: 98.9% vs. 92.5%), as well as a superior accuracy and precision in interbreath interval measurement (linear regression slopes and intercepts: 0.99, 0.026 s (R2 = 0.98) vs. 0.98, 0.11 s (R2 = 0.88), Bland–Altman limits of agreement: ±0.61 s vs. ±1.5 s). This study represents a first proof of concept for the simultaneous recording of respiration signals and forcecardiograms with a single, local, small, unobtrusive, cheap sensor. This would extend the scope of FCG to monitoring multiple vital signs, as well as to the analysis of cardiorespiratory interactions, also paving the way for the continuous, long-term monitoring of patients with heart and pulmonary diseases.
Collapse
|
42
|
Abstract
Mechanoreceptors in human skin are important and efficient cutaneous sensors that are highly sensitive, selective, and adaptive to the environment. Among these, Merkel disk (MD) and cilia are capable of sensing an external mechanical force through a receptor with a sharp pillar-like structure at its end. Then, the signal of the action potential is generated by pumping Na+ ions through ion channels. In this study, a self-powered, stretchable, and wearable gel mechanoreceptor sensor is developed inspired by the structural features of the MD and cilia with sharp tips and the signaling characteristics of mechanoreceptor ion migration. Poly(vinylidene fluoride-co-trifluoroethylene) gel is used to implement a self-powered system, and polyvinylchloride-based elastic gel is utilized to detect sensing signals based on charge transfer and distribution. The surface of all gels is that of a conical structure to achieve high sensor sensitivity and conformal contact with a target surface. In addition, using the developed sensors, various biological signals related to pressure/strain occurring in the human body (e.g., blood pressure (BP), muscle movement, and motion) are acquired. Furthermore, the behavior of arterial BP was investigated during the contraction and relaxation of the muscles.
Collapse
Affiliation(s)
- Kyoung-Yong Chun
- Institute of Advanced Machinery Design Technology, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136-713, Republic of Korea
| | - Seunghwan Seo
- School of Mechanical Engineering, College of Engineering, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136-713, Republic of Korea
| | - Chang-Soo Han
- Institute of Advanced Machinery Design Technology, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136-713, Republic of Korea
- School of Mechanical Engineering, College of Engineering, Korea University, Anam-Dong, Seongbuk-Gu, Seoul 136-713, Republic of Korea
| |
Collapse
|
43
|
Santos E, Fernandes Vara MDF, Ranciaro M, Strasse W, Nunes Nogueira Neto G, Nohama P. Influence of sensor mass and adipose tissue on the mechanomyography signal of elbow flexor muscles. J Biomech 2021; 122:110456. [PMID: 33962326 DOI: 10.1016/j.jbiomech.2021.110456] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 03/31/2021] [Accepted: 04/09/2021] [Indexed: 11/19/2022]
Abstract
Mechanomyography (MMG) is a non-invasive technique that records muscle contraction using sensors positioned on the skin's surface. Therefore, it can have its signal attenuated due to the adipose tissue, directly influencing the results. This study evaluates the influence of different mass added to a sensor's assembly and the adipose tissue on MMG signals of elbow flexor muscles. Test protocol consisted of skinfold thickness measurement of 22 volunteers, followed by applying 2-3 s electrical stimulation for muscle contraction during the acquisition of MMG signals. MMG signals were processed in the time domain, using the average of the absolute amplitude, and expressed in gravity values (G), termed here as MMG(G). Tests occurred four times with different sensor masses. MMG data were processed and analyzed statistically using Friedman and Kruskal-Wallis tests to determine the differences between the MMG signals measured with different sensor masses. The Mann-Whitney analysis indicated differences in the MMG signals between groups with different skinfold thickness. MMG(G) signals suffered attenuation with increasing sensor mass (0.4416 G to 0.94 g; 0.3902 G to 2.64 g; 0.3762 G to 5.44 g; 0.3762 G to 7.14 g) and adipose tissue.
Collapse
Affiliation(s)
- Elgison Santos
- Graduate Program in Health Technology, Pontifícia Universidade Católica do Paraná (PPGTS/PUCPR), Paraná, Brazil.
| | | | - Maira Ranciaro
- Graduate Program in Health Technology, Pontifícia Universidade Católica do Paraná (PPGTS/PUCPR), Paraná, Brazil.
| | - Wally Strasse
- Graduate Program in Electrical and Computer Engineering, Federal Technological University of Paraná UTFPR - Curitiba-Paraná/ Brazil.
| | | | - Percy Nohama
- Graduate Program in Health Technology, Pontifícia Universidade Católica do Paraná (PPGTS/PUCPR), Paraná, Brazil; Graduate Program in Electrical and Computer Engineering, Federal Technological University of Paraná UTFPR - Curitiba-Paraná/ Brazil.
| |
Collapse
|
44
|
Abstract
The actual grip force provided by a hand prosthesis is an important parameter to evaluate its efficiency. To this end, a split cylindrical handlebar embedding a single-axis load cell was designed, 3D printed and assembled. Various measurements were made to evaluate the performances of the “Federica” hand, a simple low-cost hand prosthesis. The handlebar was placed at different angular positions with respect to the hand palm, and the experimental data were processed to estimate the overall grip force. In addition, piezoresistive force sensors were applied on selected phalanxes of the prosthesis, in order to map the distribution of the grasping forces between them. The electrical current supplied to the single servomotor that actuates all the five fingers, was monitored to estimate the force exerted on the main actuator tendon, while tendon displacement was evaluated by a rotary potentiometer fixed to the servomotor shaft. The force transfer ratio of the whole system was about 12.85 %, and the mean dissipated energy for a complete cycle of closing-opening was 106.80 Nmm, resulting lower than that of many commercial prostheses. The mean grip force of the “Federica” hand was 8.80 N, that is enough to support the user in many actions of daily life, also considering the adaptive wrapping capability of the prosthesis. On average, the middle phalanges exerted the greatest grip force (2.65 N) on the handlebar, while the distal phalanges a force of 1.66 N.
Collapse
|
45
|
A Human–Computer Interface Replacing Mouse and Keyboard for Individuals with Limited Upper Limb Mobility. MULTIMODAL TECHNOLOGIES AND INTERACTION 2020. [DOI: 10.3390/mti4040084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
People with physical disabilities in their upper extremities face serious issues in using classical input devices due to lacking movement possibilities and precision. This article suggests an alternative input concept and presents corresponding input devices. The proposed interface combines an inertial measurement unit and force sensing resistors, which can replace mouse and keyboard. Head motions are mapped to mouse pointer positions, while mouse button actions are triggered by contracting mastication muscles. The contact pressures of each fingertip are acquired to replace the conventional keyboard. To allow for complex text entry, the sensory concept is complemented by an ambiguous keyboard layout with ten keys. The related word prediction function provides disambiguation at word level. Haptic feedback is provided to users corresponding to their virtual keystrokes for enhanced closed-loop interactions. This alternative input system enables text input as well as the emulation of a two-button mouse.
Collapse
|
46
|
Electrically Elicited Force Response Characteristics of Forearm Extensor Muscles for Electrical Muscle Stimulation-Based Haptic Rendering. SENSORS 2020; 20:s20195669. [PMID: 33020415 PMCID: PMC7582372 DOI: 10.3390/s20195669] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 09/28/2020] [Accepted: 10/01/2020] [Indexed: 12/15/2022]
Abstract
A haptic interface based on electrical muscle stimulation (EMS) has huge potential in terms of usability and applicability compared with conventional haptic interfaces. This study analyzed the force response characteristics of forearm extensor muscles for EMS-based haptic rendering. We introduced a simplified mathematical model of the force response, which has been developed in the field of rehabilitation, and experimentally validated its feasibility for haptic applications. Two important features of the force response, namely the peak force and response time, with respect to the frequency and amplitude of the electrical stimulation were identified by investigating the experimental force response of the forearm extensor muscles. An exponential function was proposed to estimate the peak force with respect to the frequency and amplitude, and it was verified by comparing with the measured peak force. The response time characteristics were also examined with respect to the frequency and amplitude. A frequency-dependent tendency, i.e., an increase in response time with increasing frequency, was observed, whereas there was no correlation with the amplitude. The analysis of the force response characteristics with the application of the proposed force response model may help enhance the fidelity of EMS-based haptic rendering.
Collapse
|
47
|
Prakash A, Sahi AK, Sharma N, Sharma S. Force myography controlled multifunctional hand prosthesis for upper-limb amputees. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.102122] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
48
|
Grushko S, Spurný T, Černý M. Control Methods for Transradial Prostheses Based on Remnant Muscle Activity and Its Relationship with Proprioceptive Feedback. SENSORS (BASEL, SWITZERLAND) 2020; 20:E4883. [PMID: 32872291 PMCID: PMC7506660 DOI: 10.3390/s20174883] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 08/24/2020] [Accepted: 08/25/2020] [Indexed: 02/07/2023]
Abstract
The loss of a hand can significantly affect one's work and social life. For many patients, an artificial limb can improve their mobility and ability to manage everyday activities, as well as provide the means to remain independent. This paper provides an extensive review of available biosensing methods to implement the control system for transradial prostheses based on the measured activity in remnant muscles. Covered techniques include electromyography, magnetomyography, electrical impedance tomography, capacitance sensing, near-infrared spectroscopy, sonomyography, optical myography, force myography, phonomyography, myokinetic control, and modern approaches to cineplasty. The paper also covers combinations of these approaches, which, in many cases, achieve better accuracy while mitigating the weaknesses of individual methods. The work is focused on the practical applicability of the approaches, and analyses present challenges associated with each technique along with their relationship with proprioceptive feedback, which is an important factor for intuitive control over the prosthetic device, especially for high dexterity prosthetic hands.
Collapse
Affiliation(s)
- Stefan Grushko
- Department of Robotics, VSB-Technical University of Ostrava, 70800 Ostrava, Czech Republic; (T.S.); (M.Č.)
| | | | | |
Collapse
|
49
|
Ke A, Huang J, Chen L, Gao Z, He J. An Ultra-Sensitive Modular Hybrid EMG-FMG Sensor with Floating Electrodes. SENSORS 2020; 20:s20174775. [PMID: 32846982 PMCID: PMC7506715 DOI: 10.3390/s20174775] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/16/2020] [Accepted: 08/19/2020] [Indexed: 11/16/2022]
Abstract
To improve the reliability and safety of myoelectric prosthetic control, many researchers tend to use multi-modal signals. The combination of electromyography (EMG) and forcemyography (FMG) has been proved to be a practical choice. However, an integrative and compact design of this hybrid sensor is lacking. This paper presents a novel modular EMG–FMG sensor; the sensing module has a novel design that consists of floating electrodes, which act as the sensing probe of both the EMG and FMG. This design improves the integration of the sensor. The whole system contains one data acquisition unit and eight identical sensor modules. Experiments were conducted to evaluate the performance of the sensor system. The results show that the EMG and FMG signals have good consistency under standard conditions; the FMG signal shows a better and more robust performance than the EMG. The average accuracy is 99.07% while using both the EMG and FMG signals for recognition of six hand gestures under standard conditions. Even with two layers of gauze isolated between the sensor and the skin, the average accuracy reaches 90.9% while using only the EMG signal; if we use both the EMG and FMG signals for classification, the average accuracy is 99.42%.
Collapse
Affiliation(s)
- Ang Ke
- Key Laboratory of Ministry of Education for Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan 430074, China; (A.K.); (Z.G.)
| | - Jian Huang
- Key Laboratory of Ministry of Education for Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan 430074, China; (A.K.); (Z.G.)
- Correspondence: ; Tel.: +86-136-2720-6071
| | - Luyao Chen
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China;
| | - Zhaolong Gao
- Key Laboratory of Ministry of Education for Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan 430074, China; (A.K.); (Z.G.)
| | - Jiping He
- Beijing Advanced Innovation Center for Intelligent Robots and Systems, Beijing Institute of Technology, Beijing 100081, China;
| |
Collapse
|
50
|
Andreozzi E, Fratini A, Esposito D, Naik G, Polley C, Gargiulo GD, Bifulco P. Forcecardiography: A Novel Technique to Measure Heart Mechanical Vibrations onto the Chest Wall. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3885. [PMID: 32668584 PMCID: PMC7411775 DOI: 10.3390/s20143885] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 07/08/2020] [Accepted: 07/10/2020] [Indexed: 11/17/2022]
Abstract
This paper presents forcecardiography (FCG), a novel technique to measure local, cardiac-induced vibrations onto the chest wall. Since the 19th century, several techniques have been proposed to detect the mechanical vibrations caused by cardiovascular activity, the great part of which was abandoned due to the cumbersome instrumentation involved. The recent availability of unobtrusive sensors rejuvenated the research field with the most currently established technique being seismocardiography (SCG). SCG is performed by placing accelerometers onto the subject's chest and provides information on major events of the cardiac cycle. The proposed FCG measures the cardiac-induced vibrations via force sensors placed onto the subject's chest and provides signals with a richer informational content as compared to SCG. The two techniques were compared by analysing simultaneous recordings acquired by means of a force sensor, an accelerometer and an electrocardiograph (ECG). The force sensor and the accelerometer were rigidly fixed to each other and fastened onto the xiphoid process with a belt. The high-frequency (HF) components of FCG and SCG were highly comparable (r > 0.95) although lagged. The lag was estimated by cross-correlation and resulted in about tens of milliseconds. An additional, large, low-frequency (LF) component, associated with ventricular volume variations, was observed in FCG, while not being visible in SCG. The encouraging results of this feasibility study suggest that FCG is not only able to acquire similar information as SCG, but it also provides additional information on ventricular contraction. Further analyses are foreseen to confirm the advantages of FCG as a technique to improve the scope and significance of pervasive cardiac monitoring.
Collapse
Affiliation(s)
- Emilio Andreozzi
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy
- Istituti Clinici Scientifici Maugeri S.p.A.-Società benefit, Via S. Maugeri, 10 27100 Pavia, Italy
| | - Antonio Fratini
- Biomedical Engineering, School of Life and Health Sciences, Aston University, Birmingham B4 7ET, UK
| | - Daniele Esposito
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy
- Istituti Clinici Scientifici Maugeri S.p.A.-Società benefit, Via S. Maugeri, 10 27100 Pavia, Italy
| | - Ganesh Naik
- The MARCS Institute, Western Sydney University, Penrith NSW 2751, Australia
| | - Caitlin Polley
- School of Computing, Engineering, and Mathematics, Western Sydney University, Penrith NSW 2747, Australia
| | - Gaetano D Gargiulo
- The MARCS Institute, Western Sydney University, Penrith NSW 2751, Australia
- School of Computing, Engineering, and Mathematics, Western Sydney University, Penrith NSW 2747, Australia
| | - Paolo Bifulco
- Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21 80125 Napoli, Italy
- Istituti Clinici Scientifici Maugeri S.p.A.-Società benefit, Via S. Maugeri, 10 27100 Pavia, Italy
| |
Collapse
|