Bousiotis D, Alconcel LNS, Beddows DCS, Harrison RM, Pope FD. Monitoring and apportioning sources of indoor air quality using low-cost particulate matter sensors. ENVIRONMENT INTERNATIONAL 2023; 174:107907. [PMID: 37012195 DOI: 10.1016/j.envint.2023.107907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 03/24/2023] [Accepted: 03/27/2023] [Indexed: 06/19/2023]
Abstract
Air quality is one of the most important factors in public health. While outdoor air quality is widely studied, the indoor environment has been less scrutinised, even though time spent indoors is typically much greater than outdoors. The emergence of low-cost sensors can help assess indoor air quality. This study provides a new methodology, utilizing low-cost sensors and source apportionment techniques, to understand the relative importance of indoor and outdoor air pollution sources upon indoor air quality. The methodology is tested with three sensors placed in different rooms inside an exemplar house (bedroom, kitchen and office) and one outdoors. When the family was present, the bedroom had the highest average concentrations for PM2.5 and PM10 (3.9 ± 6.8 ug/m3 and 9.6 ± 12.7 μg/m3 respectively), due to the activities undertaken there and the presence of softer furniture and carpeting. The kitchen, while presenting the lowest PM concentrations for both size ranges (2.8 ± 5.9 ug/m3 and 4.2 ± 6.9 μg/m3 respectively), presented the highest PM spikes, especially during cooking times. Increased ventilation in the office resulted in the highest PM1 concentration (1.6 ± 1.9 μg/m3), highlighting the strong effect of infiltration of outdoor air for the smallest particles. Source apportionment, via positive matrix factorisation (PMF), showed that up to 95 % of the PM1 was found to be of outdoor sources in all the rooms. This effect was reduced as particle size increased, with outdoor sources contributing >65 % of the PM2.5, and up to 50 % of the PM10, depending on the room studied. The new approach to elucidate the contributions of different sources to total indoor air pollution exposure, described in this paper, is easily scalable and translatable to different indoor locations.
Collapse
Affiliation(s)
- Dimitrios Bousiotis
- Division of Environmental Health and Risk Management, School of Geography, Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| | - Leah-Nani S Alconcel
- School of Metallurgy and Materials, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| | - David C S Beddows
- Division of Environmental Health and Risk Management, School of Geography, Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| | - Roy M Harrison
- Division of Environmental Health and Risk Management, School of Geography, Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| | - Francis D Pope
- Division of Environmental Health and Risk Management, School of Geography, Earth and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom.
| |
Collapse
|
2
|
Wiryasaputra R, Huang CY, Kristiani E, Liu PY, Yeh TK, Yang CT. Review of an intelligent indoor environment monitoring and management system for COVID-19 risk mitigation. Front Public Health 2023; 10:1022055. [PMID: 36703846 PMCID: PMC9871550 DOI: 10.3389/fpubh.2022.1022055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Accepted: 12/23/2022] [Indexed: 01/12/2023] Open
Abstract
The coronavirus disease (COVID-19) outbreak has turned the world upside down bringing about a massive impact on society due to enforced measures such as the curtailment of personal travel and limitations on economic activities. The global pandemic resulted in numerous people spending their time at home, working, and learning from home hence exposing them to air contaminants of outdoor and indoor origins. COVID-19 is caused by the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), which spreads by airborne transmission. The viruses found indoors are linked to the building's ventilation system quality. The ventilation flow in an indoor environment controls the movement and advection of any aerosols, pollutants, and Carbon Dioxide (CO2) created by indoor sources/occupants; the quantity of CO2 can be measured by sensors. Indoor CO2 monitoring is a technique used to track a person's COVID-19 risk, but high or low CO2 levels do not necessarily mean that the COVID-19 virus is present in the air. CO2 monitors, in short, can help inform an individual whether they are breathing in clean air. In terms of COVID-19 risk mitigation strategies, intelligent indoor monitoring systems use various sensors that are available in the marketplace. This work presents a review of scientific articles that influence intelligent monitoring development and indoor environmental quality management system. The paper underlines that the non-dispersive infrared (NDIR) sensor and ESP8266 microcontroller support the development of low-cost indoor air monitoring at learning facilities.
Collapse
Affiliation(s)
- Rita Wiryasaputra
- Department of Industrial Engineering and Enterprise Information, Tunghai University, Taichung, Taiwan
- Department of Informatics, Krida Wacana Christian University, Jakarta, Indonesia
| | - Chin-Yin Huang
- Department of Industrial Engineering and Enterprise Information, Tunghai University, Taichung, Taiwan
| | - Endah Kristiani
- Department of Informatics, Krida Wacana Christian University, Jakarta, Indonesia
- Department of Computer Science, Tunghai University, Taichung, Taiwan
| | - Po-Yu Liu
- Division of Infection, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan
- Ph.D. Program in Translational Medicine, National Chung Hsing University, Taichung, Taiwan
- Rong Hsing Research Center for Translational Medicine, National Chung Hsing University, Taichung, Taiwan
- Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan
- Genomic Center for Infectious Diseases, Taichung Veterans General Hospital, Taichung, Taiwan
| | - Ting-Kuang Yeh
- Division of Infection, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan
- Genomic Center for Infectious Diseases, Taichung Veterans General Hospital, Taichung, Taiwan
| | - Chao-Tung Yang
- Department of Computer Science, Tunghai University, Taichung, Taiwan
- Research Center for Smart Sustainable Circular Economy, Tunghai University, Taichung, Taiwan
| |
Collapse
|
3
|
Reis J, Lopes D, Graça D, Fernandes AP, Miranda AI, Lopes M. Using low-cost sensors to assess real-time comfort and air quality patterns in indoor households. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:7736-7751. [PMID: 36042135 DOI: 10.1007/s11356-022-22771-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 08/24/2022] [Indexed: 06/15/2023]
Abstract
People spend most of their time in indoor environments without knowing about the air quality in these spaces. In this study, indoor low-cost sensors were used (for 5 months) to assess the comfort and air quality patterns in two indoor households. To strengthen the robustness of the considered approach and build confidence in the obtained comfort and indoor air quality (IAQ) levels, the sensor measurements were also compared against information from reference monitoring equipment; in which, high correlation coefficients were obtained (> 0.85) and also low errors (on average 22%). The IAQ results were strongly influenced by the residents' activity and behaviour, the outdoor weather conditions, and indoor/outdoor air pollution sources. Overall, the recommended values of temperature and relative humidity for the occupant's comfort in indoor environments were not fulfilled. The highest particulate matter (PM) levels were recorded at the weekend (on average +14% higher), while maximum CO2 and CO levels were obtained on the weekdays (on average +9% higher). PM daily profiles followed the outdoor concentrations with the maximum levels at the end of the night and the lowest values in the early morning/mid-afternoon. The highest and lowest CO2 concentrations were registered in the early morning (< 1536 ppm) and mid-afternoon (< 627 ppm), respectively, while the CO daily profiles showed a high impact of outdoor emissions, with the minimum concentrations up to 0.81 mg m-3 (at 10 a.m. or 6 p.m.), and a maximum concentration of 1.87 mg m-3 (at 10 p.m.). Real-time comfort conditions and IAQ levels are a powerful approach to providing fast decisions to minimise human exposure and prevent negative health impacts.
Collapse
Affiliation(s)
- Johnny Reis
- CESAM - Centre for Environmental and Marine Studies, Department of Environment and Planning, University of Aveiro, Aveiro, Portugal
| | - Diogo Lopes
- CESAM - Centre for Environmental and Marine Studies, Department of Environment and Planning, University of Aveiro, Aveiro, Portugal.
| | - Daniel Graça
- CESAM - Centre for Environmental and Marine Studies, Department of Environment and Planning, University of Aveiro, Aveiro, Portugal
| | - Ana Patrícia Fernandes
- CESAM - Centre for Environmental and Marine Studies, Department of Environment and Planning, University of Aveiro, Aveiro, Portugal
| | - Ana Isabel Miranda
- CESAM - Centre for Environmental and Marine Studies, Department of Environment and Planning, University of Aveiro, Aveiro, Portugal
| | - Myriam Lopes
- CESAM - Centre for Environmental and Marine Studies, Department of Environment and Planning, University of Aveiro, Aveiro, Portugal
| |
Collapse
|
4
|
Al Huraimel K, Alhosani M, Gopalani H, Kunhabdulla S, Stietiya MH. Elucidating the role of environmental management of forests, air quality, solid waste and wastewater on the dissemination of SARS-CoV-2. HYGIENE AND ENVIRONMENTAL HEALTH ADVANCES 2022; 3:100006. [PMID: 37519421 PMCID: PMC9095661 DOI: 10.1016/j.heha.2022.100006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 04/13/2022] [Accepted: 04/30/2022] [Indexed: 11/29/2022]
Abstract
The increasing frequency of zoonotic diseases is amongst several catastrophic repercussions of inadequate environmental management. Emergence, prevalence, and lethality of zoonotic diseases is intrinsically linked to environmental management which are currently at a destructive level globally. The effects of these links are complicated and interdependent, creating an urgent need of elucidating the role of environmental mismanagement to improve our resilience to future pandemics. This review focused on the pertinent role of forests, outdoor air, indoor air, solid waste and wastewater management in COVID-19 dissemination to analyze the opportunities prevailing to control infectious diseases considering relevant data from previous disease outbreaks. Global forest management is currently detrimental and hotspots of forest fragmentation have demonstrated to result in zoonotic disease emergences. Deforestation is reported to increase susceptibility to COVID-19 due to wildfire induced pollution and loss of forest ecosystem services. Detection of SARS-CoV-2 like viruses in multiple animal species also point to the impacts of biodiversity loss and forest fragmentation in relation to COVID-19. Available literature on air quality and COVID-19 have provided insights into the potential of air pollutants acting as plausible virus carrier and aggravating immune responses and expression of ACE2 receptors. SARS-CoV-2 is detected in outdoor air, indoor air, solid waste, wastewater and shown to prevail on solid surfaces and aerosols for prolonged hours. Furthermore, lack of protection measures and safe disposal options in waste management are evoking concerns especially in underdeveloped countries due to high infectivity of SARS-CoV-2. Inadequate legal framework and non-adherence to environmental regulations were observed to aggravate the postulated risks and vulnerability to future waves of pandemics. Our understanding underlines the urgent need to reinforce the fragile status of global environmental management systems through the development of strict legislative frameworks and enforcement by providing institutional, financial and technical supports.
Collapse
Affiliation(s)
- Khaled Al Huraimel
- Division of Consultancy, Research & Innovation (CRI), Sharjah Environment Company - Bee'ah, Sharjah, United Arab Emirates
| | - Mohamed Alhosani
- Division of Consultancy, Research & Innovation (CRI), Sharjah Environment Company - Bee'ah, Sharjah, United Arab Emirates
| | - Hetasha Gopalani
- Division of Consultancy, Research & Innovation (CRI), Sharjah Environment Company - Bee'ah, Sharjah, United Arab Emirates
| | - Shabana Kunhabdulla
- Division of Consultancy, Research & Innovation (CRI), Sharjah Environment Company - Bee'ah, Sharjah, United Arab Emirates
| | - Mohammed Hashem Stietiya
- Division of Consultancy, Research & Innovation (CRI), Sharjah Environment Company - Bee'ah, Sharjah, United Arab Emirates
| |
Collapse
|
5
|
Zheng H, Krishnan V, Walker S, Loomans M, Zeiler W. Laboratory evaluation of low-cost air quality monitors and single sensors for monitoring typical indoor emission events in Dutch daycare centers. ENVIRONMENT INTERNATIONAL 2022; 166:107372. [PMID: 35777114 DOI: 10.1016/j.envint.2022.107372] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 06/13/2022] [Accepted: 06/22/2022] [Indexed: 06/15/2023]
Abstract
Daycare centers (DCCs) are where infants and toddlers (0-4 years old) spend the most time besides their homes. Given their higher susceptibility to the effects of air pollutants, as compared to older children and adults, indoor air quality (IAQ) is regarded as an essential parameter to monitor in DCCs. Recent advances in IAQ monitoring technologies have enabled the deployment of low-cost air quality monitors (LCMs) and single sensors (LCSs) to continuously monitor various indoor environments, and their performance testing should also be performed in the intended indoor applications. To our knowledge, there is no study evaluating the application of LCMs/LCSs in DCCs scenarios yet. Therefore, this study is aimed to assess the response of five types of LCMs (previously not tested) and five LCSs to typical DCCs emission activities in detecting multiple IAQ parameters, i.e., particulate matter, carbon dioxide, total volatile organic compounds, temperature, and relative humidity. These LCMs/LCSs were compared to outcomes from research-grade instruments (RGIs). All the experiments were performed in a climate chamber, where three kinds of typical activities (background; arts-and-crafts; cleaning; [in a total of 32 events]) were simulated by recruited subjects at two typical indoor climatic conditions (cool and dry [20 ± 1 °C & 40 ± 10%], warm and humid [26 ± 1 °C & 70 ± 5%]). Results showed that tested LCMs had the ability to capture DCCs activities by simultaneously monitoring multiple IAQ parameters, and LCMs/LCSs revealed a strong correlation with RGIs in most events (R2 values from 0.7 to 1), but, for some events, the magnitude of responses varied widely. Sensirion SCD41, an emerging CO2 sensor built on the photoacoustic sensing principle, had a more accurate performance than all tested NDIR-based CO2 sensors/monitors. In general, the study implies that the selection of LCMs/LCSs for a specific application of interest should be based on emission characteristics and space conditions.
Collapse
Affiliation(s)
- Hailin Zheng
- Department of the Built Environment, Eindhoven University of Technology, Eindhoven, the Netherlands.
| | - Vinayak Krishnan
- Department of the Built Environment, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Shalika Walker
- Department of the Built Environment, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Marcel Loomans
- Department of the Built Environment, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Wim Zeiler
- Department of the Built Environment, Eindhoven University of Technology, Eindhoven, the Netherlands
| |
Collapse
|
6
|
Winck JC, Almeida SM, Correia G, Gabriel MF, Marques G, Silva MG. A call for a national strategy for indoor air quality. Pulmonology 2022; 28:245-251. [PMID: 35351401 PMCID: PMC8957366 DOI: 10.1016/j.pulmoe.2022.02.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 02/13/2022] [Accepted: 02/14/2022] [Indexed: 12/04/2022] Open
Affiliation(s)
- J C Winck
- Faculdade de Medicina da Universidade do Porto, Porto 4200-319, Portugal.
| | - S M Almeida
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, EN10, km 139.7, Bobadela LRS 2695-066, Portugal
| | - G Correia
- Institute of Microbiology, FMUC - Faculty of Medicine, University of Coimbra, Coimbra, Portugal; Medical Microbiology Research Group, CIBB -Centre for Innovative Biomedicine and Biotechnology, University of Coimbra, Coimbra, Portugal
| | - M F Gabriel
- INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Campus da FEUP, Rua Dr. Roberto Frias 400, Porto 4200-465, Portugal
| | - G Marques
- Polytechnic of Coimbra, ESTGOH, Rua General Santos Costa, 3400-124 Oliveira do Hospital, Portugal
| | - M G Silva
- Universidade de Coimbra, Associação para o Desenvolvimento da Aerodinâmica Industrial, Departamento de Engenharia Mecânica, Rua Luís Reis Santos, Pólo II, Coimbra 3030-788, Portugal
| |
Collapse
|
7
|
Su Y, Cheng H, Wang Z, Wang L. Impacts of the COVID-19 lockdown on building energy consumption and indoor environment: A case study in Dalian, China. ENERGY AND BUILDINGS 2022; 263:112055. [PMID: 35370351 PMCID: PMC8959662 DOI: 10.1016/j.enbuild.2022.112055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 03/12/2022] [Accepted: 03/23/2022] [Indexed: 05/03/2023]
Abstract
Restricting social distancing is an effective means of controlling the COVID-19 pandemic, resulting in a sharp drop in the utilization of commercial buildings. However, the specific changes in the operating parameters are not clear. This study aims to quantify the impact of COVID-19 lockdowns on commercial building energy consumption and the indoor environment, including correlation analysis. A large green commercial building in Dalian, China's only country to experience five lockdowns, has been chosen. We compared the performance during the lockdown to the same period last year. The study found that the first lockdown caused a maximum 63.5% drop in monthly energy consumption, and the second lockdown was 55.2%. The energy consumption per unit area in 2020 dropped by 55.4% compared with 2019. In addition, during the lockdown, the compliance rate of indoor thermal environment increased by 34.7%, and indoor air quality was 9.5%. These findings could partly explain the short-term and far-reaching effects of the lockdown on the operating parameters of large commercial buildings. Humans are likely to coexist with COVID-19 for a long time, and commercial buildings have to adapt to new energy and health demands. Effective management strategies need to be developed.
Collapse
Affiliation(s)
- Yuan Su
- School of Architecture & Fine Art, Dalian University of Technology, Dalian 116024, China
| | - Haoyuan Cheng
- School of Architecture & Fine Art, Dalian University of Technology, Dalian 116024, China
| | - Zhe Wang
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, China
| | - Linwei Wang
- China Merchants Shekou Holdings Northeast Corporation, China
| |
Collapse
|
8
|
Jankowski T, Sobiech P, Jakubiak S. The Influence of Air Humidity on the Output Signal from an Ionization Smoke Detector in the Presence of Soot Nanoparticles. SENSORS 2022; 22:s22103639. [PMID: 35632046 PMCID: PMC9146982 DOI: 10.3390/s22103639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/27/2022] [Accepted: 05/04/2022] [Indexed: 02/05/2023]
Abstract
In 2019, the European Committee for Standardization (CEN) initiated work on the preparation of a strategy for air quality monitoring at workplaces. The aim was to determine the concentrations of nano-objects and their aggregates and agglomerates (NOAA) by means of direct measurements using low-cost sensors. There is a growing need for low-cost devices that can continuously monitor the concentrations of nanoparticles, and that can be installed where nanoparticles are used or created spontaneously. In search of such a device, in this study, a smoke detector with an ionization sensor was tested. The aim of the research was to investigate the response of the analog output signal with respect to changes in environmental parameters such as the relative humidity of air. The research was conducted in controlled laboratory conditions, and the results confirmed that an ionization detector could be used to measure the concentrations of nanoaerosols. The modified smoke detector detected soot particles smaller than 100 nm. The linear regression line was calculated for the relative humidity dataset and had a slope coefficient of −1.214 × 10−4; thus, the value of the output signal was constant during the experiment. The dependence on air temperature was approximated by a second-degree curve, with a slope coefficient of −8.113 × 10−2. Air humidity affected aerosol concentrations, which may be related to surface modification of nanoparticles.
Collapse
|
9
|
Adam MG, Tran PTM, Balasubramanian R. Air quality changes in cities during the COVID-19 lockdown: A critical review. ATMOSPHERIC RESEARCH 2021; 264:105823. [PMID: 34456403 PMCID: PMC8384485 DOI: 10.1016/j.atmosres.2021.105823] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 08/11/2021] [Accepted: 08/21/2021] [Indexed: 05/04/2023]
Abstract
In response to the rapid spread of coronavirus disease-2019 (COVID-19) within and across countries and the need to protect public health, governments worldwide introduced unprecedented measures such as restricted road and air travel and reduced human mobility in 2020. The curtailment of personal travel and economic activity provided a unique opportunity for researchers to assess the interplay between anthropogenic emissions of primary air pollutants, their physical transport, chemical transformation, ultimate fate and potential health impacts. In general, reductions in the atmospheric levels of outdoor air pollutants such as particulate matter (PM), nitrogen dioxide (NO2), carbon monoxide (CO), sulfur dioxide (SO2), and volatile organic compounds (VOCs) were observed in many countries during the lockdowns. However, the levels of ozone (O3), a secondary air pollutant linked to asthma and respiratory ailments, and secondary PM were frequently reported to remain unchanged or even increase. An increase in O3 can enhance the formation of secondary PM2.5, especially secondary organic aerosols, through the atmospheric oxidation of VOCs. Given that the gaseous precursors of O3 (VOCs and NOx) are also involved in the formation of secondary PM2.5, an integrated control strategy should focus on reducing the emission of the common precursors for the co-mitigation of PM2.5 and O3 with an emphasis on their complex photochemical interactions. Compared to outdoor air quality, comprehensive investigations of indoor air quality (IAQ) are relatively sparse. People spend more than 80% of their time indoors with exposure to air pollutants of both outdoor and indoor origins. Consequently, an integrated assessment of exposure to air pollutants in both outdoor and indoor microenvironments is needed for effective urban air quality management and for mitigation of health risk. To provide further insights into air quality, we do a critical review of scientific articles, published from January 2020 to December 2020 across the globe. Finally, we discuss policy implications of our review in the context of global air quality improvement.
Collapse
Affiliation(s)
- Max G Adam
- Department of Civil and Environmental Engineering, National University of Singapore, Singapore 117576, Singapore
| | - Phuong T M Tran
- Department of Civil and Environmental Engineering, National University of Singapore, Singapore 117576, Singapore
- Faculty of Environment, University of Science and Technology, The University of Danang, 54 Nguyen Luong Bang Street, Lien Chieu District, Danang City, Viet Nam
| | - Rajasekhar Balasubramanian
- Department of Civil and Environmental Engineering, National University of Singapore, Singapore 117576, Singapore
| |
Collapse
|
10
|
Ambient Air Quality Measurement with Low-Cost Optical and Electrochemical Sensors: An Evaluation of Continuous Year-Long Operation. ENVIRONMENTS 2021. [DOI: 10.3390/environments8110114] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Sensor technology is attractive to the public due to its availability and ease of use. However, its usage raises numerous questions. The general trustworthiness of sensor data is widely discussed, especially with regard to accuracy, precision, and long-term signal stability. The VSB-Technical University of Ostrava has operated an air quality sensor network for more than two years, and its large sets of valid results can help in understanding the limitations of sensory measurement. Monitoring is focused on the concentrations of dust particles, NO2, and ozone to verify the impact of newly planted greenery on the reduction in air pollution. The sensor network currently covers an open field on the outskirts of Ostrava, between Liberty Ironworks and the nearby ISKO1650 monitoring station, where some of the worst air pollution levels in the Czech Republic are regularly measured. In the future, trees should be allowed to grow over the sensors, enabling assessment of the green barrier effect on air pollution. As expected, the service life of the sensors varies from 1 to 3 years; therefore, checks are necessary both prior to the measurement and regularly during operation, verifying output stability and overall performance. Results of the PMx sensory measurements correlated well with the reference method. Concentration values measured by NO2 sensors correlated poorly with the reference method, although timeline plots of concentration changes were in accordance. We suggest that a comparison of timelines should be used for air quality evaluations, rather than particular values. The results showed that the sensor measurements are not yet suitable to replace the reference methods, and dense sensor networks proved useful and robust tools for indicative air quality measurements (AQM).
Collapse
|
11
|
Peladarinos N, Cheimaras V, Piromalis D, Arvanitis KG, Papageorgas P, Monios N, Dogas I, Stojmenovic M, Tsaramirsis G. Early Warning Systems for COVID-19 Infections Based on Low-Cost Indoor Air-Quality Sensors and LPWANs. SENSORS (BASEL, SWITZERLAND) 2021; 21:6183. [PMID: 34577400 PMCID: PMC8473455 DOI: 10.3390/s21186183] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 09/06/2021] [Accepted: 09/12/2021] [Indexed: 11/26/2022]
Abstract
During the last two years, the COVID-19 pandemic continues to wreak havoc in many areas of the world, as the infection spreads through person-to-person contact. Transmission and prognosis, once infected, are potentially influenced by many factors, including indoor air pollution. Particulate Matter (PM) is a complex mixture of solid and/or liquid particles suspended in the air that can vary in size, shape, and composition and recent scientific work correlate this index with a considerable risk of COVID-19 infections. Early Warning Systems (EWS) and the Internet of Things (IoT) have given rise to the development of Low Power Wide Area Networks (LPWAN) based on sensors, which measure PM levels and monitor In-door Air pollution Quality (IAQ) in real-time. This article proposes an open-source platform architecture and presents the development of a Long Range (LoRa) based sensor network for IAQ and PM measurement. A few air quality sensors were tested, a network platform was implemented after simulating setup topologies, emphasizing feasible low-cost open platform architecture.
Collapse
Affiliation(s)
- Nikolaos Peladarinos
- Department of Electrical and Electronics Engineering, University of West Attica, 12244 Athens, Greece; (N.P.); (V.C.); (P.P.); (N.M.); (I.D.)
| | - Vasileios Cheimaras
- Department of Electrical and Electronics Engineering, University of West Attica, 12244 Athens, Greece; (N.P.); (V.C.); (P.P.); (N.M.); (I.D.)
| | - Dimitrios Piromalis
- Department of Industrial Design and Production Engineering, University of West Attica, 12244 Athens, Greece;
| | - Konstantinos G. Arvanitis
- Department of Natural Resources Management and Agricultural Engineering, Agricultural University of Athens, Iera Odos 75, 11855 Athens, Greece
| | - Panagiotis Papageorgas
- Department of Electrical and Electronics Engineering, University of West Attica, 12244 Athens, Greece; (N.P.); (V.C.); (P.P.); (N.M.); (I.D.)
| | - Nikolaos Monios
- Department of Electrical and Electronics Engineering, University of West Attica, 12244 Athens, Greece; (N.P.); (V.C.); (P.P.); (N.M.); (I.D.)
| | - Ioannis Dogas
- Department of Electrical and Electronics Engineering, University of West Attica, 12244 Athens, Greece; (N.P.); (V.C.); (P.P.); (N.M.); (I.D.)
| | - Milos Stojmenovic
- Computer Science Department, Singidunum University, 160622 Beograd, Serbia;
| | - Georgios Tsaramirsis
- Higher Colleges of Technology, Abu Dhabi Women’s College, Abu Dhabi 25026, United Arab Emirates;
| |
Collapse
|
12
|
Nieckarz Z, Zoladz JA. New Calibration System for Low-Cost Suspended Particulate Matter Sensors with Controlled Air Speed, Temperature and Humidity. SENSORS 2021; 21:s21175845. [PMID: 34502737 PMCID: PMC8434339 DOI: 10.3390/s21175845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 08/25/2021] [Accepted: 08/27/2021] [Indexed: 11/16/2022]
Abstract
This paper presents a calibration system for low-cost suspended particulate matter (PM) sensors, consisting of reference instruments, enclosed space in a metal pipe (volume 0.145 m3), a duct fan, a controller and automated control software. The described system is capable of generating stable and repeatable concentrations of suspended PM in the air duct. In this paper, as the final result, we presented the process and effects of calibration of two low-cost air pollution stations—university measuring stations (UMS)—developed and used in the scientific project known as Storm&DustNet, implemented at the Jagiellonian University in Kraków (Poland), for the concentration range of PM from a few up to 240 µg·m–3. Finally, we postulate that a device of this type should be available for every system composed of a large number of low-cost PM sensors.
Collapse
Affiliation(s)
- Zenon Nieckarz
- Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, ul. Łojasiewicza 11, 30-348 Kraków, Poland
- Correspondence: ; Tel.: +48-12-664-4864
| | - Jerzy A. Zoladz
- Faculty of Health Sciences, Jagiellonian University Medical College, ul. Michałowskiego 12, 31-126 Kraków, Poland;
| |
Collapse
|
13
|
Performance Evaluation of Particulate Matter and Indoor Microclimate Monitors in University Classrooms under COVID-19 Restrictions. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18147363. [PMID: 34299813 PMCID: PMC8305222 DOI: 10.3390/ijerph18147363] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 07/05/2021] [Accepted: 07/07/2021] [Indexed: 12/17/2022]
Abstract
Optical monitors have proven their versatility into the studies of air quality in the workplace and indoor environments. The current study aimed to perform a screening of the indoor environment regarding the presence of various fractions of particulate matter (PM) and the specific thermal microclimate in a classroom occupied with students in March 2019 (before COVID-19 pandemic) and in March 2021 (during pandemic) at Valahia University Campus, Targoviste, Romania. The objectives were to assess the potential exposure of students and academic personnel to PM and to observe the performances of various sensors and monitors (particle counter, PM monitors, and indoor microclimate sensors). PM1 ranged between 29 and 41 μg m−3 and PM10 ranged between 30 and 42 μg m−3. It was observed that the particles belonged mostly to fine and submicrometric fractions in acceptable thermal environments according to the PPD and PMV indices. The particle counter recorded preponderantly 0.3, 0.5, and 1.0 micron categories. The average acute dose rate was estimated as 6.58 × 10−4 mg/kg-day (CV = 14.3%) for the 20–40 years range. Wearing masks may influence the indoor microclimate and PM levels but additional experiments should be performed at a finer scale.
Collapse
|
14
|
Bertke M, Kirsch I, Uhde E, Peiner E. Ultrafine Aerosol Particle Sizer Based on Piezoresistive Microcantilever Resonators with Integrated Air-Flow Channel. SENSORS (BASEL, SWITZERLAND) 2021; 21:3731. [PMID: 34072041 PMCID: PMC8199094 DOI: 10.3390/s21113731] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 05/21/2021] [Accepted: 05/24/2021] [Indexed: 01/11/2023]
Abstract
To monitor airborne nano-sized particles (NPs), a single-chip differential mobility particle sizer (DMPS) based on resonant micro cantilevers in defined micro-fluidic channels (µFCs) is introduced. A size bin of the positive-charged fraction of particles herein is separated from the air stream by aligning their trajectories onto the cantilever under the action of a perpendicular electrostatic field of variable strength. We use previously described µFCs and piezoresistive micro cantilevers (PMCs) of 16 ng mass fabricated using micro electro mechanical system (MEMS) technology, which offer a limit of detection of captured particle mass of 0.26 pg and a minimum detectable particulate mass concentration in air of 0.75 µg/m3. Mobility sizing in 4 bins of a nebulized carbon aerosol NPs is demonstrated based on finite element modelling (FEM) combined with a-priori knowledge of particle charge state. Good agreement of better than 14% of mass concentration is observed in a chamber test for the novel MEMS-DMPS vs. a simultaneously operated standard fast mobility particle sizer (FMPS) as reference instrument. Refreshing of polluted cantilevers is feasible without de-mounting the sensor chip from its package by multiply purging them alternately in acetone steam and clean air.
Collapse
Affiliation(s)
- Maik Bertke
- Institute for Semiconductor Technology and Laboratory for Emerging Nanometrology (LENA), Technische Universität Braunschweig, Hans-Sommer-Str. 66/Langer Kamp 6a, 38106 Braunschweig, Germany;
| | - Ina Kirsch
- Fraunhofer Wilhelm-Klauditz-Institut (WKI), Bienroder Weg 54E, 38106 Braunschweig, Germany; (I.K.); (E.U.)
| | - Erik Uhde
- Fraunhofer Wilhelm-Klauditz-Institut (WKI), Bienroder Weg 54E, 38106 Braunschweig, Germany; (I.K.); (E.U.)
| | - Erwin Peiner
- Institute for Semiconductor Technology and Laboratory for Emerging Nanometrology (LENA), Technische Universität Braunschweig, Hans-Sommer-Str. 66/Langer Kamp 6a, 38106 Braunschweig, Germany;
| |
Collapse
|
15
|
Miniature Optical Particle Counter and Analyzer Involving a Fluidic-Optronic CMOS Chip Coupled with a Millimeter-Sized Glass Optical System. SENSORS 2021; 21:s21093181. [PMID: 34063656 PMCID: PMC8124938 DOI: 10.3390/s21093181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 04/07/2021] [Accepted: 04/28/2021] [Indexed: 11/23/2022]
Abstract
Our latest advances in the field of miniaturized optical PM sensors are presented. This sensor combines a hybrid fluidic-optronic CMOS (holed retina) that is able to record a specific irradiance pattern scattered by an illuminated particle (scattering signature), while enabling the circulation of particles toward the sensing area. The holed retina is optically coupled with a monolithic, millimeter-sized, refracto-reflective optical system. The latter notably performs an optical pre-processing of signatures, with a very wide field of view of scattering angles. This improves the sensitivity of the sensors, and simplifies image processing. We report the precise design methodology for such a sensor, as well as its fabrication and characterization using calibrated polystyrene beads. Finally, we discuss its ability to characterize particles and its potential for further miniaturization and integration.
Collapse
|