1
|
Leung CLA, Wilson MD, Connolley T, Huang C. Mapping of lithium ion concentrations in 3D structures through development of in situ correlative imaging of X-ray Compton scattering-computed tomography. JOURNAL OF SYNCHROTRON RADIATION 2024; 31:888-895. [PMID: 38838165 PMCID: PMC11226152 DOI: 10.1107/s1600577524003382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 04/17/2024] [Indexed: 06/07/2024]
Abstract
Understanding the correlation between chemical and microstructural properties is critical for unraveling the fundamental relationship between materials chemistry and physical structures that can benefit materials science and engineering. Here, we demonstrate novel in situ correlative imaging of the X-ray Compton scattering computed tomography (XCS-CT) technique for studying this fundamental relationship. XCS-CT can image light elements that do not usually exhibit strong signals using other X-ray characterization techniques. This paper describes the XCS-CT setup and data analysis method for calculating the valence electron momentum density and lithium-ion concentration, and provides two examples of spatially and temporally resolved chemical properties inside batteries in 3D. XCS-CT was applied to study two types of rechargeable lithium batteries in standard coin cell casings: (1) a lithium-ion battery containing a cathode of bespoke microstructure and liquid electrolyte, and (2) a solid-state battery containing a solid-polymer electrolyte. The XCS-CT technique is beneficial to a wide variety of materials and systems to map chemical composition changes in 3D structures.
Collapse
Affiliation(s)
- Chu Lun Alex Leung
- Department of Mechanical EngineeringUniversity College LondonLondonWC1E 7JEUnited Kingdom
- Research Complex at HarwellRutherford Appleton LaboratoryDidcotOX11 0FAUnited Kingdom
| | | | | | - Chun Huang
- Research Complex at HarwellRutherford Appleton LaboratoryDidcotOX11 0FAUnited Kingdom
- Department of MaterialsImperial College LondonLondonSW7 2AZUnited Kingdom
- The Faraday InstitutionDidcotOX11 0RAUnited Kingdom
| |
Collapse
|
2
|
Vijayakumar J, Goudarzi NM, Eeckhaut G, Schrijnemakers K, Cnudde V, Boone MN. Characterization of Pharmaceutical Tablets by X-ray Tomography. Pharmaceuticals (Basel) 2023; 16:ph16050733. [PMID: 37242516 DOI: 10.3390/ph16050733] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 05/07/2023] [Accepted: 05/08/2023] [Indexed: 05/28/2023] Open
Abstract
Solid dosage forms such as tablets are extensively used in drug administration for their simplicity and large-scale manufacturing capabilities. High-resolution X-ray tomography is one of the most valuable non-destructive techniques to investigate the internal structure of the tablets for drug product development as well as for a cost effective production process. In this work, we review the recent developments in high-resolution X-ray microtomography and its application towards different tablet characterizations. The increased availability of powerful laboratory instrumentation, as well as the advent of high brilliance and coherent 3rd generation synchrotron light sources, combined with advanced data processing techniques, are driving the application of X-ray microtomography forward as an indispensable tool in the pharmaceutical industry.
Collapse
Affiliation(s)
- Jaianth Vijayakumar
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| | - Niloofar Moazami Goudarzi
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| | - Guy Eeckhaut
- Janssen Pharmaceutica, Turnhoutseweg 30, 2340 Beerse, Belgium
| | | | - Veerle Cnudde
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Pore-Scale Processes in Geomaterials Research (PProGRess), Department of Geology, Ghent University, Krijgslaan 281/S8, 9000 Gent, Belgium
- Environmental Hydrogeology, Department of Earth Sciences, Faculty of Geosciences, Utrecht University, Princetonlaan 8A, 3584 CD Utrecht, The Netherlands
| | - Matthieu N Boone
- Centre for X-ray Tomography (UGCT), Ghent University, Proeftuinstraat 86/N3, 9000 Gent, Belgium
- Department of Physics and Astronomy, Radiation Physics, Ghent University, Proeftuinstraat 86/N12, 9000 Gent, Belgium
| |
Collapse
|
3
|
Pommé S, Veale MC, Pooley DE, Van Assche F, Falksohn F, Collins SM. Analysis of a neutron-induced conversion electron spectrum of gadolinium. Appl Radiat Isot 2023; 197:110828. [PMID: 37126950 DOI: 10.1016/j.apradiso.2023.110828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/25/2023] [Accepted: 04/17/2023] [Indexed: 05/03/2023]
Abstract
A 100-nm-thick gadolinium layer deposited on a pixelated silicon sensor was activated in a neutron field to measure the internal conversion electron (ICE) spectrum generated by neutron capture products of 155Gd and 157Gd. The experiment was performed at the ISIS neutron and muon facility, using a bespoke version of the HEXITEC spectroscopic imaging camera. Signals originating from internal conversion electrons, Auger electrons, x rays and gamma rays up to 150 keV were identified. The ICE spectrum has an energy resolution of 1.8-1.9 keV at 72 keV and shows peaks from the K, L, M, N+ ICEs of the 79.51 keV and 88.967 keV 2+-0+ gamma transitions from the first excited states in 158Gd and 156Gd, respectively, as well as the K ICEs of the 4+-2+ transitions at 181.931 keV and 199.213 keV from the respective second excited states. Spectrum analysis was performed using a convolution of a Gaussian with exponential functions at the low and high energy side as the peak shaping function. Relative ICE intensities were derived from the fitted peak areas and compared with internal conversion coefficient (ICC) values calculated from the BrIcc database. Relative to the dominant L shell contribution, the K ICE intensity conforms to BrIcc and the M, N, O+ ICE intensities are somewhat higher than expected.
Collapse
Affiliation(s)
- S Pommé
- European Commission, Joint Research Centre (JRC), Geel, Belgium.
| | - M C Veale
- Technology Department, Rutherford Appleton Laboratory (STFC), Oxfordshire, UK
| | - D E Pooley
- ISIS Neutron and Muon Source, Rutherford Appleton Laboratory (STFC), Oxfordshire, UK
| | | | - F Falksohn
- National Physical Laboratory (NPL), Teddington, UK
| | - S M Collins
- National Physical Laboratory (NPL), Teddington, UK; School of Mathematics and Physics, University of Surrey, Guilford, UK
| |
Collapse
|
4
|
Huang C, Wilson MD, Suzuki K, Liotti E, Connolley T, Magdysyuk OV, Collins S, Van Assche F, Boone MN, Veale MC, Lui A, Wheater R, Leung CLA. 3D Correlative Imaging of Lithium Ion Concentration in a Vertically Oriented Electrode Microstructure with a Density Gradient. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2105723. [PMID: 35404540 PMCID: PMC9165496 DOI: 10.1002/advs.202105723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 03/10/2022] [Indexed: 06/14/2023]
Abstract
The performance of Li+ ion batteries (LIBs) is hindered by steep Li+ ion concentration gradients in the electrodes. Although thick electrodes (≥300 µm) have the potential for reducing the proportion of inactive components inside LIBs and increasing battery energy density, the Li+ ion concentration gradient problem is exacerbated. Most understanding of Li+ ion diffusion in the electrodes is based on computational modeling because of the low atomic number (Z) of Li. There are few experimental methods to visualize Li+ ion concentration distribution of the electrode within a battery of typical configurations, for example, coin cells with stainless steel casing. Here, for the first time, an interrupted in situ correlative imaging technique is developed, combining novel, full-field X-ray Compton scattering imaging with X-ray computed tomography that allows 3D pixel-by-pixel mapping of both Li+ stoichiometry and electrode microstructure of a LiNi0.8 Mn0.1 Co0.1 O2 cathode to correlate the chemical and physical properties of the electrode inside a working coin cell battery. An electrode microstructure containing vertically oriented pore arrays and a density gradient is fabricated. It is shown how the designed electrode microstructure improves Li+ ion diffusivity, homogenizes Li+ ion concentration through the ultra-thick electrode (1 mm), and improves utilization of electrode active materials.
Collapse
Affiliation(s)
- Chun Huang
- Department of MaterialsImperial College LondonLondonSW7 2AZUK
- The Faraday InstitutionQuad One, Becquerel Ave, Harwell CampusDidcotOX11 0RAUK
- Department of MaterialsUniversity of OxfordOxfordOX1 3PHUK
- Research Complex at HarwellRutherford Appleton LaboratoryDidcotOxfordshireOX11 0FAUK
- Department of EngineeringKing's College LondonLondonWC2R 2LSUK
| | - Matthew D. Wilson
- STFC‐UKRIRutherford Appleton LaboratoryHarwell CampusDidcotOxfordshireOX11 0QXUK
| | - Kosuke Suzuki
- Faculty of Science and TechnologyGunma University1‐5‐1 Tenjin‐cho, KiryuGunma376‐8515Japan
| | - Enzo Liotti
- Department of MaterialsUniversity of OxfordOxfordOX1 3PHUK
| | - Thomas Connolley
- Diamond Light SourceHarwell Science and Innovation CampusDidcotOxfordshireOX11 0QXUK
| | - Oxana V. Magdysyuk
- Diamond Light SourceHarwell Science and Innovation CampusDidcotOxfordshireOX11 0QXUK
| | - Stephen Collins
- Diamond Light SourceHarwell Science and Innovation CampusDidcotOxfordshireOX11 0QXUK
| | - Frederic Van Assche
- Radiation PhysicsDepartment of Physics and AstronomyFaculty of SciencesGhent UniversityProeftuinstraat 86/N12Gent9000Belgium
| | - Matthieu N. Boone
- Radiation PhysicsDepartment of Physics and AstronomyFaculty of SciencesGhent UniversityProeftuinstraat 86/N12Gent9000Belgium
| | - Matthew C. Veale
- STFC‐UKRIRutherford Appleton LaboratoryHarwell CampusDidcotOxfordshireOX11 0QXUK
| | - Andrew Lui
- Department of MaterialsUniversity of OxfordOxfordOX1 3PHUK
| | - Rhian‐Mair Wheater
- STFC‐UKRIRutherford Appleton LaboratoryHarwell CampusDidcotOxfordshireOX11 0QXUK
| | - Chu Lun Alex Leung
- Research Complex at HarwellRutherford Appleton LaboratoryDidcotOxfordshireOX11 0FAUK
- Department of Mechanical EngineeringUniversity College LondonLondonWC1E 7JEUK
| |
Collapse
|
5
|
Batey DJ, Van Assche F, Vanheule S, Boone MN, Parnell AJ, Mykhaylyk OO, Rau C, Cipiccia S. X-Ray Ptychography with a Laboratory Source. PHYSICAL REVIEW LETTERS 2021; 126:193902. [PMID: 34047586 DOI: 10.1103/physrevlett.126.193902] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 03/19/2021] [Accepted: 04/08/2021] [Indexed: 06/12/2023]
Abstract
X-ray ptychography has revolutionized nanoscale phase contrast imaging at large-scale synchrotron sources in recent years. We present here the first successful demonstration of the technique in a small-scale laboratory setting. An experiment was conducted with a liquid metal-jet x-ray source and a single photon-counting detector with a high spectral resolution. The experiment used a spot size of 5 μm to produce a ptychographic phase image of a Siemens star test pattern with a submicron spatial resolution. The result and methodology presented show how high-resolution phase contrast imaging can now be performed at small-scale laboratory sources worldwide.
Collapse
Affiliation(s)
- Darren J Batey
- Diamond Light Source, Harwell Science and Innovation Campus, Fermi Avenue, Didcot OX11 0DE, United Kingdom
| | - Frederic Van Assche
- UGCT-RP, Department of Physics and Astronomy, Ghent University, Ghent 9000, Belgium
| | - Sander Vanheule
- UGCT-RP, Department of Physics and Astronomy, Ghent University, Ghent 9000, Belgium
| | - Matthieu N Boone
- UGCT-RP, Department of Physics and Astronomy, Ghent University, Ghent 9000, Belgium
| | - Andrew J Parnell
- Department of Physics and Astronomy, University of Sheffield, Sheffield S3 7RH, United Kingdom
| | - Oleksandr O Mykhaylyk
- Soft Matter Analytical Laboratory, Department of Chemistry, University of Sheffield, Sheffield S3 7HF, United Kingdom
| | - Christoph Rau
- Diamond Light Source, Harwell Science and Innovation Campus, Fermi Avenue, Didcot OX11 0DE, United Kingdom
| | - Silvia Cipiccia
- Diamond Light Source, Harwell Science and Innovation Campus, Fermi Avenue, Didcot OX11 0DE, United Kingdom
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom
| |
Collapse
|