Su TJ, Lin WH, Zhuang QY, Hung YC, Yang WR, He BJ, Wang SM. Application of Independent Component Analysis and Nelder-Mead Particle Swarm Optimization Algorithm in Non-Contact Blood Pressure Estimation. SENSORS (BASEL, SWITZERLAND) 2024; 24:3544. [PMID: 38894333 PMCID: PMC11174942 DOI: 10.3390/s24113544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 05/25/2024] [Accepted: 05/28/2024] [Indexed: 06/21/2024]
Abstract
In recent years, hypertension has become one of the leading causes of illness and death worldwide. Changes in lifestyle among the population have led to an increasing prevalence of hypertension. This study proposes a non-contact blood pressure estimation method that allows patients to conveniently monitor their blood pressure values. By utilizing a webcam to track facial features and the region of interest (ROI) for obtaining forehead images, independent component analysis (ICA) is employed to eliminate artifact signals. Subsequently, physiological parameters are calculated using the principle of optical wave reflection. The Nelder-Mead (NM) simplex method is combined with the particle swarm optimization (PSO) algorithm to optimize the empirical parameters, thus enhancing computational efficiency and accurately determining the optimal solution for blood pressure estimation. The influences of light intensity and camera distance on the experimental results are also discussed. Furthermore, the measurement time is only 10 s. The superior accuracy and efficiency of the proposed methodology are demonstrated by comparing them with those in other published literature.
Collapse
Affiliation(s)
- Te-Jen Su
- Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan; (T.-J.S.); (W.-H.L.); (Q.-Y.Z.); (Y.-C.H.); (W.-R.Y.); (B.-J.H.)
| | - Wei-Hong Lin
- Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan; (T.-J.S.); (W.-H.L.); (Q.-Y.Z.); (Y.-C.H.); (W.-R.Y.); (B.-J.H.)
| | - Qian-Yi Zhuang
- Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan; (T.-J.S.); (W.-H.L.); (Q.-Y.Z.); (Y.-C.H.); (W.-R.Y.); (B.-J.H.)
| | - Ya-Chung Hung
- Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan; (T.-J.S.); (W.-H.L.); (Q.-Y.Z.); (Y.-C.H.); (W.-R.Y.); (B.-J.H.)
| | - Wen-Rong Yang
- Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan; (T.-J.S.); (W.-H.L.); (Q.-Y.Z.); (Y.-C.H.); (W.-R.Y.); (B.-J.H.)
| | - Bo-Jun He
- Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan; (T.-J.S.); (W.-H.L.); (Q.-Y.Z.); (Y.-C.H.); (W.-R.Y.); (B.-J.H.)
| | - Shih-Ming Wang
- Department of Computer Science and Information Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan
| |
Collapse
|
2
|
Shokouhmand A, Jiang X, Ayazi F, Ebadi N. MEMS Fingertip Strain Plethysmography for Cuffless Estimation of Blood Pressure. IEEE J Biomed Health Inform 2024; 28:2699-2712. [PMID: 38442050 DOI: 10.1109/jbhi.2024.3372968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
OBJECTIVE To develop a cuffless method for estimating blood pressure (BP) from fingertip strain plethysmography (SPG) recordings. METHODS A custom-built micro-electromechanical systems (MEMS) strain sensor is employed to record heartbeat-induced vibrations at the fingertip. An XGboost regressor is then trained to relate SPG recordings to beat-to-beat systolic BP (SBP), diastolic BP (DBP), mean arterial pressure (MAP) values. For this purpose, each SPG segment in this setup is represented by a feature vector consisting of cardiac time interval, amplitude features, statistical properties, and demographic information of the subjects. In addition, a novel concept, coined geometric features, are introduced and incorporated into the feature space to further encode the dynamics in SPG recordings. The performance of the regressor is assessed on 32 healthy subjects through 5-fold cross-validation (5-CV) and leave-subject-out cross validation (LSOCV). RESULTS Mean absolute errors (MAEs) of 3.88 mmHg and 5.45 mmHg were achieved for DBP and SBP estimations, respectively, in the 5-CV setting. LSOCV yielded MAEs of 8.16 mmHg for DBP and 16.81 mmHg for SBP. Through feature importance analysis, 3 geometric and 26 integral-related features introduced in this work were identified as primary contributors to BP estimation. The method exhibited robustness against variations in blood pressure level (normal to critical) and body mass index (underweight to obese), with MAE ranges of [1.28, 4.28] mmHg and [2.64, 7.52] mmHg, respectively. CONCLUSION The findings suggest high potential for SPG-based BP estimation at the fingertip. SIGNIFICANCE This study presents a fundamental step towards the augmentation of optical sensors that are susceptible to dark skin tones.
Collapse
|
3
|
Pankaj, Kumar A, Komaragiri R, Kumar M. Blood pressure estimation and classification using a reference signal-less photoplethysmography signal: a deep learning framework. Phys Eng Sci Med 2023; 46:1589-1605. [PMID: 37747644 DOI: 10.1007/s13246-023-01322-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Accepted: 08/21/2023] [Indexed: 09/26/2023]
Abstract
The markers that help to predict th function of a cardiovascular system are hemodynamic parameters like blood pressure (BP), stroke volume, heart rate, and cardiac output. Continuous analysis of hemodynamic parameters such as BP can detect abnormalities earlier, preventing cardiovascular diseases (CVDs). However, sometimes due to motion artifacts, it becomes difficult to monitor the BP accurately and classify it. This work presents an optimized deep learning model having the capability to estimate the systolic blood pressure (SBP) and diastolic blood pressure (DBP) and classify the BP stages simultaneously from the same network using only a single channel photoplethysmography (PPG) signal. The proposed model is designed by exploiting the deep learning framework of a convolutional neural network (CNN), exhibiting the inherent ability to extract features automatically. Moreover, the proposed framework utilizes the superlet transform method to transform a 1-D PPG signal into a 2-D super-resolution time-frequency (TF) spectrogram. A superlet transform separates the peaks related to true PPG signal components and motion artifacts components. Thus, the superlet provides a robust realtime approach to accurately estimating and classifying BP using a single PPG sensor signal and does not require additional ECG and PPG sensor signals for reference. Using a super-resolution spectrogram and CNN model makes the method profitable in motion artifact removal, feature selection, and extraction. Hence the proposed framework becomes less complex for deployment on wearable devices having limited battery resources. The performance of the proposed framework is demonstrated on the publicly available larger dataset MIMIC-III. This work obtained a mean absolute error (MAE) of 2.71 mmHg and 2.42 mmHg for SBP and DBP, respectively. The classification accuracy for the SBP prediction is about 96.79%, whereas it is 98.94% for DBP. From a motion artifact-affected PPG signal, SBP and DBP are estimated. Then the estimated BP is classified into three categories: normotension, prehypertension, and hypertension, and is compared with the state of art methods to show the effectiveness of the proposed optimized framework.
Collapse
Affiliation(s)
- Pankaj
- Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India
| | - Ashish Kumar
- Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India
- School of Computer science engineering and technology, Bennett University, Greater Noida, India
| | - Rama Komaragiri
- Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India
| | - Manjeet Kumar
- Department of Electronics and Communication Engineering, Delhi Technological University, Delhi, India.
| |
Collapse
|
4
|
Sultan MA, Saadeh W. Continuous Patient-Independent Estimation of Respiratory Rate and Blood Pressure Using Robust Spectro-Temporal Features Derived From Photoplethysmogram Only. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2023; 5:637-649. [PMID: 39184965 PMCID: PMC11342923 DOI: 10.1109/ojemb.2023.3329728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 09/20/2023] [Accepted: 10/26/2023] [Indexed: 08/27/2024] Open
Abstract
Objective: A patient-independent approach for continuous estimation of vital signs using robust spectro-temporal features derived from only photoplethysmogram (PPG) signal. Methods: In the pre-processing stage, we remove baseline shifts and artifacts of the PPG signal using Incremental Merge Segmentation with adaptive thresholding. From the cleaned PPG, we extract multiple parameters independent of individual patient PPG morphology for both Respiration Rate (RR) and Blood Pressure (BP). In addition, we derived a set of novel spectral and statistical features strongly correlated to BP. We proposed robust correlation-based feature selection methods for accurate RR estimates. For fewer computations and accurate measurements of BP, the most significant features are selected using correlation and mutual information measures in the feature engineering part. Finally, RR and BP are estimated using breath counting and a neural network regression model, respectively. Results: The proposed approach outperforms the current state-of-the-art in both RR and BP. The RR algorithm results in mean absolute errors (median, 25th-75th percentiles) of 0.4 (0.1-0.7) for CapnoBase dataset and 0.5(0.3-2.8) for BIDMC dataset without discarding any data window. Similarly, BP approach has been validated on a large dataset derived from MIMIC-II ([Formula: see text]1700 records) which has errors (mean absolute, standard deviation) of 5.0(6.3) and 3.0(4.0) for systolic and diastolic BP, respectively. The results meet the American Association for the Advancement of Medical Instrumentation (AAMI) and British Hypertension Society (BHS) Class A criteria. Conclusion: By using robust features and feature selection methods, we alleviated patient dependency to have reliable estimates of vitals.
Collapse
Affiliation(s)
- Muhammad Ahmad Sultan
- Electrical Engineering DepartmentLahore University of Management Sciences (LUMS)Lahore54792Pakistan
| | - Wala Saadeh
- The Engineering and Design DepartmentWestern Washington University (WWU)BellinghamWA98225USA
| |
Collapse
|
5
|
Xiao H, Song W, Liu C, Peng B, Zhu M, Jiang B, Liu Z. Reconstruction of central arterial pressure waveform based on CBi-SAN network from radial pressure waveform. Artif Intell Med 2023; 145:102683. [PMID: 37925212 DOI: 10.1016/j.artmed.2023.102683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Revised: 05/30/2023] [Accepted: 10/06/2023] [Indexed: 11/06/2023]
Abstract
The central arterial pressure (CAP) is an important physiological indicator of the human cardiovascular system which represents one of the greatest threats to human health. Accurate non-invasive detection and reconstruction of CAP waveforms are crucial for the reliable treatment of cardiovascular system diseases. However, the traditional methods are reconstructed with relatively low accuracy, and some deep learning neural network models also have difficulty in extracting features, as a result, these methods have potential for further advancement. In this study, we proposed a novel model (CBi-SAN) to implement an end-to-end relationship from radial artery pressure (RAP) waveform to CAP waveform, which consisted of the convolutional neural network (CNN), the bidirectional long-short-time memory network (BiLSTM), and the self-attention mechanism to improve the performance of CAP reconstruction. The data on invasive measurements of CAP and RAP waveform were used in 62 patients before and after medication to develop and validate the performance of CBi-SAN model for reconstructing CAP waveform. We compared it with traditional methods and deep learning models in mean absolute error (MAE), root mean square error (RMSE), and Spearman correlation coefficient (SCC). Study results indicated the CBi-SAN model performed great performance on CAP waveform reconstruction (MAE: 2.23 ± 0.11 mmHg, RMSE: 2.21 ± 0.07 mmHg), concurrently, the best reconstruction effect was obtained in the central artery systolic pressure (CASP) and the central artery diastolic pressure(CADP) (RMSECASP: 2.94 ± 0.48 mmHg, RMSECADP: 1.96 ± 0.06 mmHg). These results implied the performance of the CAP reconstruction based on CBi-SAN model was superior to the existing methods, hopped to be effectively applied to clinical practice in the future.
Collapse
Affiliation(s)
- Hanguang Xiao
- College of Artificial Intelligent, Chongqing University of Technology, Chongqing 401135, China.
| | - Wangwang Song
- College of Artificial Intelligent, Chongqing University of Technology, Chongqing 401135, China
| | - Chang Liu
- College of Artificial Intelligent, Chongqing University of Technology, Chongqing 401135, China
| | - Bo Peng
- College of Artificial Intelligent, Chongqing University of Technology, Chongqing 401135, China
| | - Mi Zhu
- College of Artificial Intelligent, Chongqing University of Technology, Chongqing 401135, China
| | - Bin Jiang
- College of Artificial Intelligent, Chongqing University of Technology, Chongqing 401135, China
| | - Zhi Liu
- College of Artificial Intelligent, Chongqing University of Technology, Chongqing 401135, China.
| |
Collapse
|
6
|
Mahardika T NQ, Fuadah YN, Jeong DU, Lim KM. PPG Signals-Based Blood-Pressure Estimation Using Grid Search in Hyperparameter Optimization of CNN-LSTM. Diagnostics (Basel) 2023; 13:2566. [PMID: 37568929 PMCID: PMC10417316 DOI: 10.3390/diagnostics13152566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 07/24/2023] [Accepted: 07/26/2023] [Indexed: 08/13/2023] Open
Abstract
Researchers commonly use continuous noninvasive blood-pressure measurement (cNIBP) based on photoplethysmography (PPG) signals to monitor blood pressure conveniently. However, the performance of the system still needs to be improved. Accuracy and precision in blood-pressure measurements are critical factors in diagnosing and managing patients' health conditions. Therefore, we propose a convolutional long short-term memory neural network (CNN-LSTM) with grid search ability, which provides a robust blood-pressure estimation system by extracting meaningful information from PPG signals and reducing the complexity of hyperparameter optimization in the proposed model. The multiparameter intelligent monitoring for intensive care III (MIMIC III) dataset obtained PPG and arterial-blood-pressure (ABP) signals. We obtained 75,226 signal segments, with 60,180 signals allocated for training data, 12,030 signals allocated for the validation set, and 15,045 signals allocated for the test data. During training, we applied five-fold cross-validation with a grid-search method to select the best model and determine the optimal hyperparameter settings. The optimized configuration of the CNN-LSTM layers consisted of five convolutional layers, one long short-term memory (LSTM) layer, and two fully connected layers for blood-pressure estimation. This study successfully achieved good accuracy in assessing both systolic blood pressure (SBP) and diastolic blood pressure (DBP) by calculating the standard deviation (SD) and the mean absolute error (MAE), resulting in values of 7.89 ± 3.79 and 5.34 ± 2.89 mmHg, respectively. The optimal configuration of the CNN-LSTM provided satisfactory performance according to the standards set by the British Hypertension Society (BHS), the Association for the Advancement of Medical Instrumentation (AAMI), and the Institute of Electrical and Electronics Engineers (IEEE) for blood-pressure monitoring devices.
Collapse
Affiliation(s)
- Nurul Qashri Mahardika T
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Gyeongbuk, Republic of Korea; (N.Q.M.T.); (Y.N.F.); (D.U.J.)
| | - Yunendah Nur Fuadah
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Gyeongbuk, Republic of Korea; (N.Q.M.T.); (Y.N.F.); (D.U.J.)
- School of Electrical Engineering, Telkom University, Bandung 40257, Indonesia
| | - Da Un Jeong
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Gyeongbuk, Republic of Korea; (N.Q.M.T.); (Y.N.F.); (D.U.J.)
| | - Ki Moo Lim
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Gyeongbuk, Republic of Korea; (N.Q.M.T.); (Y.N.F.); (D.U.J.)
- Computational Medicine Lab, Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Gyeongbuk, Republic of Korea
- Meta Heart Co., Ltd., Gumi 39177, Gyeongbuk, Republic of Korea
| |
Collapse
|
7
|
Wang W, Mohseni P, Kilgore KL, Najafizadeh L. Demographic Information Fusion Using Attentive Pooling In CNN-GRU Model For Systolic Blood Pressure Estimation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38082724 DOI: 10.1109/embc40787.2023.10340926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Fusing demographic information into deep learning models has become of interest in recent end-to-end cuff-less blood pressure (BP) estimation studies in order to achieve improved performance. Conventionally, the demographic feature vector is concatenated with the pooled embedding vector. Here, using an attention-based convolutional neural network-gated recurrent unit (CNN-GRU), we present a new approach and fuse the demographic information into the attentive pooling module. Our results demonstrate that, under calibration-based testing protocol, the proposed approach provides improved systolic blood pressure (SBP) estimation accuracy (with R2=0.86 and mean absolute error (MAE)=4.90 mmHg) compared to both the baseline model with no demographic information fused, and the conventional approach of fusing demographic information. Our work showcases the feasibility of using attention-based methods to combine demographic features with deep learning models, and suggests new ways for fusing demographic information in deep learning models to achieve improved BP estimation accuracy.
Collapse
|
8
|
Zhao L, Liang C, Huang Y, Zhou G, Xiao Y, Ji N, Zhang YT, Zhao N. Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring. NPJ Digit Med 2023; 6:93. [PMID: 37217650 DOI: 10.1038/s41746-023-00835-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 05/05/2023] [Indexed: 05/24/2023] Open
Abstract
Cardiovascular diseases (CVDs) are a leading cause of death worldwide. For early diagnosis, intervention and management of CVDs, it is highly desirable to frequently monitor blood pressure (BP), a vital sign closely related to CVDs, during people's daily life, including sleep time. Towards this end, wearable and cuffless BP extraction methods have been extensively researched in recent years as part of the mobile healthcare initiative. This review focuses on the enabling technologies for wearable and cuffless BP monitoring platforms, covering both the emerging flexible sensor designs and BP extraction algorithms. Based on the signal type, the sensing devices are classified into electrical, optical, and mechanical sensors, and the state-of-the-art material choices, fabrication methods, and performances of each type of sensor are briefly reviewed. In the model part of the review, contemporary algorithmic BP estimation methods for beat-to-beat BP measurements and continuous BP waveform extraction are introduced. Mainstream approaches, such as pulse transit time-based analytical models and machine learning methods, are compared in terms of their input modalities, features, implementation algorithms, and performances. The review sheds light on the interdisciplinary research opportunities to combine the latest innovations in the sensor and signal processing research fields to achieve a new generation of cuffless BP measurement devices with improved wearability, reliability, and accuracy.
Collapse
Affiliation(s)
- Lei Zhao
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Cunman Liang
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yan Huang
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
| | - Guodong Zhou
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
| | - Yiqun Xiao
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Nan Ji
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yuan-Ting Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Ni Zhao
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China.
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China.
| |
Collapse
|
9
|
Seo Y, Kwon S, Sunarya U, Park S, Park K, Jung D, Cho Y, Park C. Blood pressure estimation and its recalibration assessment using wrist cuff blood pressure monitor. Biomed Eng Lett 2023; 13:221-233. [PMID: 37124108 PMCID: PMC10130301 DOI: 10.1007/s13534-023-00271-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 01/02/2023] [Accepted: 02/16/2023] [Indexed: 05/02/2023] Open
Abstract
The rapid evolution of wearable technology in healthcare sectors has created the opportunity for people to measure their blood pressure (BP) using a smartwatch at any time during their daily activities. Several commercially-available wearable devices have recently been equipped with a BP monitoring feature. However, concerns about recalibration remain. Pulse transit time (PTT)-based estimation is required for initial calibration, followed by periodic recalibration. Recalibration using arm-cuff BP monitors is not practical during everyday activities. In this study, we investigated recalibration using PTT-based BP monitoring aided by a deep neural network (DNN) and validated the performance achieved with more practical wrist-cuff BP monitors. The PTT-based prediction produced a mean absolute error (MAE) of 4.746 ± 1.529 mmHg for systolic blood pressure (SBP) and 3.448 ± 0.608 mmHg for diastolic blood pressure (DBP) when tested with an arm-cuff monitor employing recalibration. Recalibration clearly improved the performance of both DNN and conventional linear regression approaches. We established that the periodic recalibration performed by a wrist-worn BP monitor could be as accurate as that obtained with an arm-worn monitor, confirming the suitability of wrist-worn devices for everyday use. This is the first study to establish the potential of wrist-cuff BP monitors as a means to calibrate BP monitoring devices that can reliably substitute for arm-cuff BP monitors. With the use of wrist-cuff BP monitoring devices, continuous BP estimation, as well as frequent calibrations to ensure accurate BP monitoring, are now feasible.
Collapse
Affiliation(s)
- Youjung Seo
- Department of Computer Engineering, Kwangwoon University, Seoul, 01897 Korea
| | - Saehim Kwon
- Department of Artificial Intelligence, Kwangwoon University, Seoul, 01897 Korea
| | - Unang Sunarya
- Department of Computer Engineering, Kwangwoon University, Seoul, 01897 Korea
- School of Applied Science, Telkom University, Bandung, 40257 Indonesia
| | - Sungmin Park
- Department of Convergence IT Engineering and the Department of Electrical Engineering, Pohang University of Science and Technology, Pohang, 37673 Korea
| | - Kwangsuk Park
- Department of Biomedical Engineering, College of Medicine, Seoul National University, Seoul, 03080 Korea
| | - Dawoon Jung
- Center for Artificial Intelligence, Korea Institute of Science and Technology, Seoul, 13916 Korea
| | - Youngho Cho
- Department of Electrical and Communication Engineering, University of Daelim, Anyang, 13916 Korea
| | - Cheolsoo Park
- Department of Computer Engineering, Kwangwoon University, Seoul, 01897 Korea
| |
Collapse
|
10
|
González S, Hsieh WT, Chen TPC. A benchmark for machine-learning based non-invasive blood pressure estimation using photoplethysmogram. Sci Data 2023; 10:149. [PMID: 36944668 PMCID: PMC10030661 DOI: 10.1038/s41597-023-02020-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 02/14/2023] [Indexed: 03/23/2023] Open
Abstract
Blood Pressure (BP) is an important cardiovascular health indicator. BP is usually monitored non-invasively with a cuff-based device, which can be bulky and inconvenient. Thus, continuous and portable BP monitoring devices, such as those based on a photoplethysmography (PPG) waveform, are desirable. In particular, Machine Learning (ML) based BP estimation approaches have gained considerable attention as they have the potential to estimate intermittent or continuous BP with only a single PPG measurement. Over the last few years, many ML-based BP estimation approaches have been proposed with no agreement on their modeling methodology. To ease the model comparison, we designed a benchmark with four open datasets with shared preprocessing, the right validation strategy avoiding information shift and leak, and standard evaluation metrics. We also adapted Mean Absolute Scaled Error (MASE) to improve the interpretability of model evaluation, especially across different BP datasets. The proposed benchmark comes with open datasets and codes. We showcase its effectiveness by comparing 11 ML-based approaches of three different categories.
Collapse
|
11
|
Wang CF, Wang TY, Kuo PH, Wang HL, Li SZ, Lin CM, Chan SC, Liu TY, Lo YC, Lin SH, Chen YY. Upper-Arm Photoplethysmographic Sensor with One-Time Calibration for Long-Term Blood Pressure Monitoring. BIOSENSORS 2023; 13:321. [PMID: 36979533 PMCID: PMC10046397 DOI: 10.3390/bios13030321] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/16/2023] [Accepted: 02/23/2023] [Indexed: 06/18/2023]
Abstract
Wearable cuffless photoplethysmographic blood pressure monitors have garnered widespread attention in recent years; however, the long-term performance values of these devices are questionable. Most cuffless blood pressure monitors require initial baseline calibration and regular recalibrations with a cuffed blood pressure monitor to ensure accurate blood pressure estimation, and their estimation accuracy may vary over time if left uncalibrated. Therefore, this study assessed the accuracy and long-term performance of an upper-arm, cuffless photoplethysmographic blood pressure monitor according to the ISO 81060-2 standard. This device was based on a nonlinear machine-learning model architecture with a fine-tuning optimized method. The blood pressure measurement protocol followed a validation procedure according to the standard, with an additional four weekly blood pressure measurements over a 1-month period, to assess the long-term performance values of the upper-arm, cuffless photoplethysmographic blood pressure monitor. The results showed that the photoplethysmographic signals obtained from the upper arm had better qualities when compared with those measured from the wrist. When compared with the cuffed blood pressure monitor, the means ± standard deviations of the difference in BP at week 1 (baseline) were -1.36 ± 7.24 and -2.11 ± 5.71 mmHg for systolic and diastolic blood pressure, respectively, which met the first criterion of ≤5 ± ≤8.0 mmHg and met the second criterion of a systolic blood pressure ≤ 6.89 mmHg and a diastolic blood pressure ≤ 6.84 mmHg. The differences in the uncalibrated blood pressure values between the test and reference blood pressure monitors measured from week 2 to week 5 remained stable and met both criteria 1 and 2 of the ISO 81060-2 standard. The upper-arm, cuffless photoplethysmographic blood pressure monitor in this study generated high-quality photoplethysmographic signals with satisfactory accuracy at both initial calibration and 1-month follow-ups. This device could be a convenient and practical tool to continuously measure blood pressure over long periods of time.
Collapse
Affiliation(s)
- Ching-Fu Wang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
- Biomedical Engineering Research and Development Center, National Yang Ming Chiao Tung University, Taipei 112304, Taiwan
| | - Ting-Yun Wang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
- Material and Chemical Research Laboratories, Industrial Technology Research Institute, No. 195, Sec. 4, Chunghsing Rd., Hsinchu 310401, Taiwan
| | - Pei-Hsin Kuo
- Department of Neurology, Hualien Tzu Chi Hospital, Buddhist Tzu chi Medical Foundation, No. 707, Sec. 3, Zhongyang Rd., Hualien 970473, Taiwan
- Department of Neurology, School of Medicine, Tzu Chi University, Hualien 97004, Taiwan
| | - Han-Lin Wang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
| | - Shih-Zhang Li
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
| | - Chia-Ming Lin
- Microlife Corporation, 9F, No. 431, Ruiguang Rd., Taipei 114063, Taiwan
| | - Shih-Chieh Chan
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
- Microlife Corporation, 9F, No. 431, Ruiguang Rd., Taipei 114063, Taiwan
| | - Tzu-Yu Liu
- Material and Chemical Research Laboratories, Industrial Technology Research Institute, No. 195, Sec. 4, Chunghsing Rd., Hsinchu 310401, Taiwan
| | - Yu-Chun Lo
- The Ph.D. Program in Medical Neuroscience, College of Medical Science and Technology, Taipei Medical University, No. 250, Wu-Xing St., Taipei 11031, Taiwan
| | - Sheng-Huang Lin
- Department of Neurology, Hualien Tzu Chi Hospital, Buddhist Tzu chi Medical Foundation, No. 707, Sec. 3, Zhongyang Rd., Hualien 970473, Taiwan
- Department of Neurology, School of Medicine, Tzu Chi University, Hualien 97004, Taiwan
| | - You-Yin Chen
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, No. 155, Sec. 2, Linong St., Taipei 112304, Taiwan
- The Ph.D. Program in Medical Neuroscience, College of Medical Science and Technology, Taipei Medical University, No. 250, Wu-Xing St., Taipei 11031, Taiwan
- Medical Device Innovation and Translation Center, National Yang Ming Chiao Tung University, Taipei 112304, Taiwan
| |
Collapse
|
12
|
Wang W, Mohseni P, Kilgore KL, Najafizadeh L. PulseDB: A large, cleaned dataset based on MIMIC-III and VitalDB for benchmarking cuff-less blood pressure estimation methods. Front Digit Health 2023; 4:1090854. [PMID: 36844249 PMCID: PMC9944565 DOI: 10.3389/fdgth.2022.1090854] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Accepted: 12/28/2022] [Indexed: 02/10/2023] Open
Abstract
There has been a growing interest in developing cuff-less blood pressure (BP) estimation methods to enable continuous BP monitoring from electrocardiogram (ECG) and/or photoplethysmogram (PPG) signals. The majority of these methods have been evaluated using publicly-available datasets, however, there exist significant discrepancies across studies with respect to the size, the number of subjects, and the applied pre-processing steps for the data that is eventually used for training and testing the models. Such differences make conducting performance comparison across models largely unfair, and mask the generalization capability of various BP estimation methods. To fill this important gap, this paper presents "PulseDB," the largest cleaned dataset to date, for benchmarking BP estimation models that also fulfills the requirements of standardized testing protocols. PulseDB contains 1) 5,245,454 high-quality 10 -s segments of ECG, PPG, and arterial BP (ABP) waveforms from 5,361 subjects retrieved from the MIMIC-III waveform database matched subset and the VitalDB database; 2) subjects' identification and demographic information, that can be utilized as additional input features to improve the performance of BP estimation models, or to evaluate the generalizability of the models to data from unseen subjects; and 3) positions of the characteristic points of the ECG/PPG signals, making PulseDB directly usable for training deep learning models with minimal data pre-processing. Additionally, using this dataset, we conduct the first study to provide insights about the performance gap between calibration-based and calibration-free testing approaches for evaluating generalizability of the BP estimation models. We expect PulseDB, as a user-friendly, large, comprehensive and multi-functional dataset, to be used as a reliable source for the evaluation of cuff-less BP estimation methods.
Collapse
Affiliation(s)
- Weinan Wang
- Integrated Systems and NeuroImaging Laboratory, Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, United States
| | - Pedram Mohseni
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - Kevin L. Kilgore
- Department of Physical Medicine & Rehabilitation, Case Western Reserve University and The MetroHealth System, Cleveland, OH, United States
| | - Laleh Najafizadeh
- Integrated Systems and NeuroImaging Laboratory, Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, United States
| |
Collapse
|
13
|
Aguirre N, Cymberknop LJ, Grall-Maës E, Ipar E, Armentano RL. Central Arterial Dynamic Evaluation from Peripheral Blood Pressure Waveforms Using CycleGAN: An In Silico Approach. SENSORS (BASEL, SWITZERLAND) 2023; 23:1559. [PMID: 36772599 PMCID: PMC9919893 DOI: 10.3390/s23031559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/18/2023] [Accepted: 01/28/2023] [Indexed: 06/18/2023]
Abstract
Arterial stiffness is a major condition related to many cardiovascular diseases. Traditional approaches in the assessment of arterial stiffness supported by machine learning techniques are limited to the pulse wave velocity (PWV) estimation based on pressure signals from the peripheral arteries. Nevertheless, arterial stiffness can be assessed based on the pressure-strain relationship by analyzing its hysteresis loop. In this work, the capacity of deep learning models based on generative adversarial networks (GANs) to transfer pressure signals from the peripheral arterial region to pressure and area signals located in the central arterial region is explored. The studied signals are from a public and validated virtual database. Compared to other works in which the assessment of arterial stiffness was performed via PWV, in the present work the pressure-strain hysteresis loop is reconstructed and evaluated in terms of classical machine learning metrics and clinical parameters. Least-square GAN (LSGAN) and Wasserstein GAN with gradient penalty (WGAN-GP) adversarial losses are compared, yielding better results with LSGAN. LSGAN mean ± standard deviation of error for pressure and area pulse waveforms are 0.8 ± 0.4 mmHg and 0.1 ± 0.1 cm2, respectively. Regarding the pressure-strain elastic modulus, it is achieved a mean absolute percentage error of 6.5 ± 5.1%. GAN-based deep learning models can recover the pressure-strain loop of central arteries while observing pressure signals from peripheral arteries.
Collapse
Affiliation(s)
- Nicolas Aguirre
- GIBIO, Facultad Regional Buenos Aires, Universidad Tecnológica Nacional, Buenos Aires C1179AAQ, Argentina
- LIST3N, Université de Technologie de Troyes, 10004 Troyes, France
| | - Leandro J. Cymberknop
- GIBIO, Facultad Regional Buenos Aires, Universidad Tecnológica Nacional, Buenos Aires C1179AAQ, Argentina
| | - Edith Grall-Maës
- LIST3N, Université de Technologie de Troyes, 10004 Troyes, France
| | - Eugenia Ipar
- GIBIO, Facultad Regional Buenos Aires, Universidad Tecnológica Nacional, Buenos Aires C1179AAQ, Argentina
| | - Ricardo L. Armentano
- GIBIO, Facultad Regional Buenos Aires, Universidad Tecnológica Nacional, Buenos Aires C1179AAQ, Argentina
| |
Collapse
|
14
|
Qin K, Huang W, Zhang T, Tang S. Machine learning and deep learning for blood pressure prediction: a methodological review from multiple perspectives. Artif Intell Rev 2022. [DOI: 10.1007/s10462-022-10353-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
15
|
Baumgartner C, Deserno TM. Best Research Papers in the Field of Sensors, Signals, and Imaging Informatics 2021. Yearb Med Inform 2022; 31:296-302. [PMID: 36463887 PMCID: PMC9719749 DOI: 10.1055/s-0042-1742545] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022] Open
Abstract
OBJECTIVES In this synopsis, we identify and highlight research papers representing noteworthy developments in signals, sensors, and imaging informatics in 2021. METHODS A broad literature search was conducted on PubMed and Scopus databases. We combined Medical Subject Heading (MeSH) terms and keywords to construct particular queries for sensors, signals, and imaging informatics. Except for the sensor section, we only consider papers that have been published in journals providing at least three articles in the query response. Using a three-point Likert scale (1=not include, 2=maybe include, and 3=include), we reviewed the titles and abstracts of all database returns. Only those papers which reached two times three points were further considered for full paper review using the same Likert scale. Again, we only considered works with two times three points and provided these for external reviews. Based on the external reviews, we selected three best papers, as it happens that the three highest ranked papers represent works from all three parts of this section: sensors, signals, and imaging informatics. RESULTS The search for papers was executed in January 2022. After removing duplicates and conference proceedings, the query returned a set of 88, 376, and 871 papers for sensors, signals, and imaging informatics, respectively. For signals and images, we filtered out journals that had less than three papers in the query results, reducing the number of papers to 215 and 512, respectively. From this total of 815 papers, the section co-editors identified 35 candidate papers with two times three Likert points, from which nine candidate best papers were nominated after full paper assessment. At least three external reviewers then rated the remaining papers and the three best-ranked papers were selected using the composite rating of all external reviewers. By accident, these three papers represent each of the three fields of sensor, signal, and imaging informatics. They were approved by consensus of the International Medical Informatics Association (IMIA) Yearbook editorial board. Deep and machine learning techniques are still a dominant topic as well as concepts beyond the state-of-the-art. CONCLUSIONS Sensors, signals, and imaging informatics is a dynamic field of intense research. Current research focuses on creating and processing heterogeneous sensor data towards meaningful decision support in clinical settings.
Collapse
Affiliation(s)
- Christian Baumgartner
- Institute of Health Care Engineering with European Testing Center of Medical Devices, Graz University of Technology, Austria,Correspondence to: Christian Baumgartner
| | - Thomas M. Deserno
- Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School, Braunschweig, Germany
| |
Collapse
|
16
|
Advances in Cuffless Continuous Blood Pressure Monitoring Technology Based on PPG Signals. BIOMED RESEARCH INTERNATIONAL 2022; 2022:8094351. [PMID: 36217389 PMCID: PMC9547685 DOI: 10.1155/2022/8094351] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Accepted: 07/30/2022] [Indexed: 11/17/2022]
Abstract
Objective. To review the progress of research on photoplethysmography- (PPG-) based cuffless continuous blood pressure monitoring technologies and prospect the challenges that need to be addressed in the future. Methods. Using Web of Science and PubMed as search engines, the literature on cuffless continuous blood pressure studies using PPG signals in the recent five years were searched. Results. Based on the retrieved literature, this paper describes the available open datasets, commonly used signal preprocessing methods, and model evaluation criteria. Early researches employed multisite PPG signals to calculate pulse wave velocity or time and predicted blood pressure by a simple linear equation. Later, extensive researches were dedicated to mine the features of PPG signals related to blood pressure and regressed blood pressure by machine learning models. Most recently, many researches have emerged to experiment with complex deep learning models for blood pressure prediction with the raw PPG signal as input. Conclusion. This paper summarized the methods in the retrieved literature, provided insight into the artificial intelligence algorithms employed in the literature, and concluded with a discussion of the challenges and opportunities for the development of cuffless continuous blood pressure monitoring technologies.
Collapse
|
17
|
Comparison of pulse rate variability and morphological features of photoplethysmograms in estimation of blood pressure. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
18
|
Liu Z, Zhou C, Wang H, He Y. Blood pressure monitoring techniques in the natural state of multi-scenes: A review. Front Med (Lausanne) 2022; 9:851172. [PMID: 36091712 PMCID: PMC9462511 DOI: 10.3389/fmed.2022.851172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Accepted: 08/11/2022] [Indexed: 11/17/2022] Open
Abstract
Blood pressure is one of the basic physiological parameters of human physiology. Frequent and repeated measurement of blood pressure along with recording of environmental or other physiological parameters when measuring blood pressure may reveal important cardiovascular risk factors that can predict occurrence of cardiovascular events. Currently, wearable non-invasive blood pressure measurement technology has attracted much research attention. Several different technical routes have been proposed to solve the challenge between portability or continuity of measurement methods and medical level accuracy of measurement results. The accuracy of blood pressure measurement technology based on auscultation and oscillography has been clinically verified, while majority of other technical routes are being explored at laboratory or multi-center clinical demonstration stage. Normally, Blood pressure measurement based on oscillographic method outside the hospital can only be measured at intervals. There is a need to develop techniques for frequent and high-precision blood pressure measurement under natural conditions outside the hospital. In this paper, we discussed the current status of blood pressure measurement technology and development trends of blood pressure measurement technology in different scenarios. We focuses on the key technical challenges and the latest advances in the study of miniaturization devices based on oscillographic method at wrist and PTT related method at finger positions as well as technology processes. This study is of great significance to the application of high frequency blood pressure measurement technology.
Collapse
Affiliation(s)
- Ziyi Liu
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
- Guangdong Transtek Medical Electronics Co., Ltd., Zhongshan, China
| | - Congcong Zhou
- Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, China
- Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, China
| | - Hongwei Wang
- Tongde Hospital of Zhejiang Province, Hangzhou, China
- *Correspondence: Hongwei Wang,
| | - Yong He
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
- Yong He,
| |
Collapse
|
19
|
Weakly Supervised Learning for Transmission Line Detection Using Unpaired Image-to-Image Translation. REMOTE SENSING 2022. [DOI: 10.3390/rs14143421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
To achieve full autonomy of unmanned aerial vehicles (UAVs), obstacle detection and avoidance are indispensable parts of visual recognition systems. In particular, detecting transmission lines is an important topic due to the potential risk of accidents while operating at low altitude. Even though many studies have been conducted to detect transmission lines, there still remains many challenges due to their thin shapes in diverse backgrounds. Moreover, most previous methods require a significant level of human involvement to generate pixel-level ground truth data. In this paper, we propose a transmission line detection algorithm based on weakly supervised learning and unpaired image-to-image translation. The proposed algorithm only requires image-level labels, and a novel attention module, which is called parallel dilated attention (PDA), improves the detection accuracy by recalibrating channel importance based on the information from various receptive fields. Finally, we construct a refinement network based on unpaired image-to-image translation in order that the prediction map is guided to detect line-shaped objects. The proposed algorithm outperforms the state-of-the-art method by 2.74% in terms of F1-score, and experimental results demonstrate that the proposed method is effective for detecting transmission lines in both quantitative and qualitative aspects.
Collapse
|
20
|
Markuleva M, Gerashchenko M, Gerashchenko S, Khizbullin R, Ivshin I. The Hemodynamic Parameters Values Prediction on the Non-Invasive Hydrocuff Technology Basis with a Neural Network Applying. SENSORS 2022; 22:s22114229. [PMID: 35684849 PMCID: PMC9185255 DOI: 10.3390/s22114229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 05/20/2022] [Accepted: 05/25/2022] [Indexed: 12/10/2022]
Abstract
The task to develop a mechanism for predicting the hemodynamic parameters values based on non-invasive hydrocuff technology of a pulse wave signal fixation is described in this study. The advantages and disadvantages of existing methods of recording the ripple curve are noted in the published materials. This study proposes a new hydrocuff method for hemodynamic parameters and blood pressure values measuring. A block diagram of the device being developed is presented. Algorithms for processing the pulse wave contour are presented. A neural network applying necessity for the multiparametric feature space formation is substantiated. The pulse wave contours obtained using hydrocuff technology of oscillation formation for various age groups are presented. According to preliminary estimates, by the moment of the dicrotic surge formation, it is possible to judge the ratio of the heart and blood vessels work, which makes it possible to form an expanded feature space of significant parameters based on neural network classifiers. This study presents the characteristics accounted for creating a database for training a neural network.
Collapse
Affiliation(s)
- Marina Markuleva
- Medical Cybernetics and Computer Science Department, Penza State University, 440026 Penza, Russia; marina-- (M.M.); (M.G.); (S.G.)
| | - Mikhail Gerashchenko
- Medical Cybernetics and Computer Science Department, Penza State University, 440026 Penza, Russia; marina-- (M.M.); (M.G.); (S.G.)
| | - Sergey Gerashchenko
- Medical Cybernetics and Computer Science Department, Penza State University, 440026 Penza, Russia; marina-- (M.M.); (M.G.); (S.G.)
| | - Robert Khizbullin
- Kazan State Power Engineering University, Krasnoselskaya, 51, 420066 Kazan, Russia;
- Correspondence:
| | - Igor Ivshin
- Kazan State Power Engineering University, Krasnoselskaya, 51, 420066 Kazan, Russia;
| |
Collapse
|
21
|
Kim DK, Kim YT, Kim H, Kim DJ. DeepCNAP: A Deep Learning Approach for Continuous Noninvasive Arterial Blood Pressure Monitoring Using Photoplethysmography. IEEE J Biomed Health Inform 2022; 26:3697-3707. [PMID: 35511844 DOI: 10.1109/jbhi.2022.3172514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Arterial blood pressure (ABP) monitoring may permit the early diagnosis and management of cardiovascular disease (CVD); however, existing methods for measuring ABP outside the clinic use inconvenient cuff sphygmomanometry, or do not estimate continuous ABP waveforms. This study proposes a novel deep learning model DeepCNAP for estimating continuous BP waveform from a noninvasively measured photoplethysmography (PPG) signal in real time. DeepCNAP was designed through the combination of deep convolutional networks and self-attention. The proposed method was constructed via 10-fold cross-validation based on the MIMIC database (the number of subjects = 942, recording time = 374.43 hours). The performance of DeepCNAP was evaluated from two perspectives: estimating ABP from PPG and classifying hemodynamically unstable events (i.e., hypertension, prehypertension, hypotension, and the normal state). The mean absolute errors of the BP estimates were 3.40 4.36 mmHg for systolic BP, 1.75 2.25 mmHg for diastolic BP, and 3.23 2.21 mmHg for the BP waveform, indicating that DeepCNAP satisfies the standards of both the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI). From the estimated BP, hypertension, prehypertension, hypotension, and the normal state were classified with 99.44, 97.58, 92.23, and 94.64% accuracy, respectively. DeepCNAP enables feasible real-time estimation of invasively measured ABP from noninvasive PPG. With its noninvasive nature, high accuracy, and clinical relevance, the proposed model could be valuable in general wards at hospitals and for wearable devices in daily life.
Collapse
|
22
|
Chen JW, Huang HK, Fang YT, Lin YT, Li SZ, Chen BW, Lo YC, Chen PC, Wang CF, Chen YY. A Data-Driven Model with Feedback Calibration Embedded Blood Pressure Estimator Using Reflective Photoplethysmography. SENSORS (BASEL, SWITZERLAND) 2022; 22:1873. [PMID: 35271020 PMCID: PMC8914760 DOI: 10.3390/s22051873] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 02/07/2022] [Accepted: 02/25/2022] [Indexed: 12/05/2022]
Abstract
Ambulatory blood pressure (BP) monitoring (ABPM) is vital for screening cardiovascular activity. The American College of Cardiology/American Heart Association guideline for the prevention, detection, evaluation, and management of BP in adults recommends measuring BP outside the office setting using daytime ABPM. The recommendation to use night-day BP measurements to confirm hypertension is consistent with the recommendation of several other guidelines. In recent studies, ABPM was used to measure BP at regular intervals, and it reduces the effect of the environment on BP. Out-of-office measurements are highly recommended by almost all hypertension organizations. However, traditional ABPM devices based on the oscillometric technique usually interrupt sleep. For all-day ABPM purposes, a photoplethysmography (PPG)-based wrist-type device has been developed as a convenient tool. This optical, noninvasive device estimates BP using morphological characteristics from PPG waveforms. As measurement can be affected by multiple variables, calibration is necessary to ensure that the calculated BP values are accurate. However, few studies focused on adaptive calibration. A novel adaptive calibration model, which is data-driven and embedded in a wearable device, was proposed. The features from a 15 s PPG waveform and personal information were input for estimation of BP values and our data-driven calibration model. The model had a feedback calibration process using the exponential Gaussian process regression method to calibrate BP values and avoid inter- and intra-subject variability, ensuring accuracy in long-term ABPM. The estimation error of BP (ΔBP = actual BP-estimated BP) of systolic BP was -0.1776 ± 4.7361 mmHg; ≤15 mmHg, 99.225%, and of diastolic BP was -0.3846 ± 6.3688 mmHg; ≤15 mmHg, 98.191%. The success rate was improved, and the results corresponded to the Association for the Advancement of Medical Instrumentation standard and British Hypertension Society Grading criteria for medical regulation. Using machine learning with a feedback calibration model could be used to assess ABPM for clinical purposes.
Collapse
Affiliation(s)
- Jia-Wei Chen
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan; (J.-W.C.); (Y.-T.F.); (S.-Z.L.); (B.-W.C.)
| | - Hsin-Kai Huang
- Department of Cardiology, Ten-Chan General Hospital (Chung Li), Taoyuan 32043, Taiwan;
| | - Yu-Ting Fang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan; (J.-W.C.); (Y.-T.F.); (S.-Z.L.); (B.-W.C.)
- Food and Drug Administration, Ministry of Health and Welfare, Taipei 11561, Taiwan
| | - Yen-Ting Lin
- Department of Internal Medicine, Taoyuan General Hospital, Ministry of Health and Welfare, Taoyuan 33004, Taiwan;
| | - Shih-Zhang Li
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan; (J.-W.C.); (Y.-T.F.); (S.-Z.L.); (B.-W.C.)
| | - Bo-Wei Chen
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan; (J.-W.C.); (Y.-T.F.); (S.-Z.L.); (B.-W.C.)
| | - Yu-Chun Lo
- The Ph.D. Program for Neural Regenerative Medicine, Taipei Medical University, Taipei 11031, Taiwan;
| | - Po-Chuan Chen
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA;
| | - Ching-Fu Wang
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan; (J.-W.C.); (Y.-T.F.); (S.-Z.L.); (B.-W.C.)
- Biomedical Engineering Research and Development Center, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan
| | - You-Yin Chen
- Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan; (J.-W.C.); (Y.-T.F.); (S.-Z.L.); (B.-W.C.)
- The Ph.D. Program for Neural Regenerative Medicine, Taipei Medical University, Taipei 11031, Taiwan;
| |
Collapse
|
23
|
Cuffless Blood Pressure Measurement Using Linear and Nonlinear Optimized Feature Selection. Diagnostics (Basel) 2022; 12:diagnostics12020408. [PMID: 35204499 PMCID: PMC8870879 DOI: 10.3390/diagnostics12020408] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 01/30/2022] [Accepted: 01/30/2022] [Indexed: 02/04/2023] Open
Abstract
The cuffless blood pressure (BP) measurement allows for frequent measurement without discomfort to the patient compared to the cuff inflation measurement. With the availability of a large dataset containing physiological waveforms, now it is possible to use them through different learning algorithms to produce a relationship with changes in BP. In this paper, a novel cuffless noninvasive blood pressure measurement technique has been proposed using optimized features from electrocardiogram and photoplethysmography based on multivariate symmetric uncertainty (MSU). The technique is an improvement over other contemporary methods due to the inclusion of feature optimization depending on both linear and nonlinear relationships with the change of blood pressure. MSU has been used as a selection criterion with algorithms such as the fast correlation and ReliefF algorithms followed by the penalty-based regression technique to make sure the features have maximum relevance as well as minimum redundancy. The result from the technique was compared with the performance of similar techniques using the MIMIC-II dataset. After training and testing, the root mean square error (RMSE) comes as 5.28 mmHg for systolic BP and 5.98 mmHg for diastolic BP. In addition, in terms of mean absolute error, the result improved to 4.27 mmHg for SBP and 5.01 for DBP compared to recent cuffless BP measurement techniques which have used substantially large datasets and feature optimization. According to the British Hypertension Society Standard (BHS), our proposed technique achieved at least grade B in all cumulative criteria for cuffless BP measurement.
Collapse
|
24
|
Heart Rate Measurement Based on 3D Central Difference Convolution with Attention Mechanism. SENSORS 2022; 22:s22020688. [PMID: 35062649 PMCID: PMC8781886 DOI: 10.3390/s22020688] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 01/12/2022] [Accepted: 01/14/2022] [Indexed: 12/04/2022]
Abstract
Remote photoplethysmography (rPPG) is a video-based non-contact heart rate measurement technology. It is a fact that most existing rPPG methods fail to deal with the spatiotemporal features of the video, which is significant for the extraction of the rPPG signal. In this paper, we propose a 3D central difference convolutional network (CDCA-rPPGNet) to measure heart rate, with an attention mechanism to combine spatial and temporal features. First, we crop and stitch the region of interest together through facial landmarks. Next, the high-quality regions of interest are fed to CDCA-rPPGNet based on a central difference convolution, which can enhance the spatiotemporal representation and capture rich relevant time contexts by collecting time difference information. In addition, we integrate the attention module into the neural network, aiming to strengthen the ability of the neural network to extract video channels and spatial features, so as to obtain more accurate rPPG signals. In summary, the three main contributions of this paper are as follows: (1) the proposed network base on central difference convolution could better capture the subtle color changes to recover the rPPG signals; (2) the proposed ROI extraction method provides high-quality input to the network; (3) the attention module is used to strengthen the ability of the network to extract features. Extensive experiments are conducted on two public datasets—the PURE dataset and the UBFC-rPPG dataset. In terms of the experiment results, our proposed method achieves 0.46 MAE (bpm), 0.90 RMSE (bpm) and 0.99 R value of Pearson’s correlation coefficient on the PURE dataset, and 0.60 MAE (bpm), 1.38 RMSE (bpm) and 0.99 R value of Pearson’s correlation coefficient on the UBFC dataset, which proves the effectiveness of our proposed approach.
Collapse
|
25
|
Bikia V, Fong T, Climie RE, Bruno RM, Hametner B, Mayer C, Terentes-Printzios D, Charlton PH. Leveraging the potential of machine learning for assessing vascular ageing: state-of-the-art and future research. EUROPEAN HEART JOURNAL. DIGITAL HEALTH 2021; 2:676-690. [PMID: 35316972 PMCID: PMC7612526 DOI: 10.1093/ehjdh/ztab089] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Vascular ageing biomarkers have been found to be predictive of cardiovascular risk independently of classical risk factors, yet are not widely used in clinical practice. In this review, we present two basic approaches for using machine learning (ML) to assess vascular age: parameter estimation and risk classification. We then summarize their role in developing new techniques to assess vascular ageing quickly and accurately. We discuss the methods used to validate ML-based markers, the evidence for their clinical utility, and key directions for future research. The review is complemented by case studies of the use of ML in vascular age assessment which can be replicated using freely available data and code.
Collapse
Affiliation(s)
- Vasiliki Bikia
- Laboratory of Hemodynamics and Cardiovascular Technology (LHTC), Swiss Federal Institute of Technology, CH-1015 Lausanne, Vaud, Switzerland
| | - Terence Fong
- Baker Heart and Diabetes Institute, 75 Commercial Rd, Melbourne, Victoria, 3004 Australia,Department of Cardiometabolic Health, Melbourne Medical School, University of Melbourne, Grattan Street, Parkville, Victoria, 3010 Australia
| | - Rachel E Climie
- Baker Heart and Diabetes Institute, 75 Commercial Rd, Melbourne, Victoria, 3004 Australia,Université de Paris, INSERM U970, Paris Cardiovascular Research Centre, Integrative Epidemiology of Cardiovascular Disease, Paris, France
| | - Rosa-Maria Bruno
- Université de Paris, INSERM U970, Paris Cardiovascular Research Centre, Integrative Epidemiology of Cardiovascular Disease, Paris, France
| | - Bernhard Hametner
- Center for Health & Bioresources, AIT Austrian Institute of Technology, Giefinggasse 4, 1210 Vienna, Austria
| | - Christopher Mayer
- Center for Health & Bioresources, AIT Austrian Institute of Technology, Giefinggasse 4, 1210 Vienna, Austria
| | - Dimitrios Terentes-Printzios
- First Department of Cardiology, Hippokration Hospital, Medical School, National and Kapodistrian University of Athens, 114 Vasilissis Sofias Avenue, 11527, Athens, Greece
| | - Peter H Charlton
- Department of Public Health and Primary Care, Strangeways Research Laboratory, 2 Worts' Causeway, Cambridge, CB1 8RN, UK,Research Centre for Biomedical Engineering, City, University of London, Northampton Square, London, EC1V 0HB, UK,Corresponding author.
| |
Collapse
|
26
|
Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder. SENSORS 2021; 21:s21186264. [PMID: 34577471 PMCID: PMC8469191 DOI: 10.3390/s21186264] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 09/13/2021] [Accepted: 09/15/2021] [Indexed: 01/09/2023]
Abstract
This study evaluates cardiovascular and cerebral hemodynamics systems by only using non-invasive electrocardiography (ECG) signals. The Massachusetts General Hospital/Marquette Foundation (MGH/MF) and Cerebral Hemodynamic Autoregulatory Information System Database (CHARIS DB) from the PhysioNet database are used for cardiovascular and cerebral hemodynamics, respectively. For cardiovascular hemodynamics, the ECG is used for generating the arterial blood pressure (ABP), central venous pressure (CVP), and pulmonary arterial pressure (PAP). Meanwhile, for cerebral hemodynamics, the ECG is utilized for the intracranial pressure (ICP) generator. A deep convolutional autoencoder system is applied for this study. The cross-validation method with Pearson’s linear correlation (R), root mean squared error (RMSE), and mean absolute error (MAE) are measured for the evaluations. Initially, the ECG is used to generate the cardiovascular waveform. For the ABP system—the systolic blood pressure (SBP) and diastolic blood pressures (DBP)—the R evaluations are 0.894 ± 0.004 and 0.881 ± 0.005, respectively. The MAE evaluations for SBP and DBP are, respectively, 6.645 ± 0.353 mmHg and 3.210 ± 0.104 mmHg. Furthermore, for the PAP system—the systolic and diastolic pressures—the R evaluations are 0.864 ± 0.003 mmHg and 0.817 ± 0.006 mmHg, respectively. The MAE evaluations for systolic and diastolic pressures are, respectively, 3.847 ± 0.136 mmHg and 2.964 ± 0.181 mmHg. Meanwhile, the mean CVP evaluations are 0.916 ± 0.001, 2.220 ± 0.039 mmHg, and 1.329 ± 0.036 mmHg, respectively, for R, RMSE, and MAE. For the mean ICP evaluation in cerebral hemodynamics, the R and MAE evaluations are 0.914 ± 0.003 and 2.404 ± 0.043 mmHg, respectively. This study, as a proof of concept, concludes that the non-invasive cardiovascular and cerebral hemodynamics systems can be potentially investigated by only using the ECG signal.
Collapse
|
27
|
Cuffless blood pressure estimation based on composite neural network and graphics information. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.103001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
28
|
Mejía-Mejía E, May JM, Elgendi M, Kyriacou PA. Classification of blood pressure in critically ill patients using photoplethysmography and machine learning. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 208:106222. [PMID: 34166851 DOI: 10.1016/j.cmpb.2021.106222] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 05/26/2021] [Indexed: 06/13/2023]
Abstract
OBJECTIVE The aim of this study was to evaluate the capability of features extracted from photoplethysmography (PPG) based Pulse Rate Variability (PRV) to classify hypertensive, normotensive and hypotensive events, and to estimate mean arterial, systolic and diastolic blood pressure in critically ill patients. METHODS Time-domain, frequency-domain and non-linear indices from PRV were extracted from 5-min and 1-min segments obtained from PPG signals. These features were filtered using machine learning algorithms in order to obtain the optimal combination for the classification of hypertensive, hypotensive and normotensive events, and for the estimation of blood pressure. RESULTS 5-min segments allowed for an improved performance in both classification and estimation tasks. Classification of blood pressure states showed around 70% accuracy and around 75% specificity. The sensitivity, precision and F1 scores were around 50%. In estimating mean arterial, systolic, and diastolic blood pressure, mean absolute errors as low as 2.55 ± 0.78 mmHg, 4.74 ± 2.33 mmHg, and 1.78 ± 0.14 mmHg were obtained, respectively. Bland-Altman analysis and Wilcoxon rank sum tests showed good agreement between real and estimated values, especially for mean and diastolic arterial blood pressures. CONCLUSION PRV-based features could be used for the classification of blood pressure states and the estimation of blood pressure values, although including additional features from the PPG waveform could improve the results. SIGNIFICANCE PRV contains information related to blood pressure, which may aid in the continuous, noninvasive, non-intrusive estimation of blood pressure and detection of hypertensive and hypotensive events in critically ill subjects.
Collapse
Affiliation(s)
- Elisa Mejía-Mejía
- Research Centre for Biomedical Engineering, City, University of London, London, United Kingdom.
| | - James M May
- Research Centre for Biomedical Engineering, City, University of London, London, United Kingdom
| | | | - Panayiotis A Kyriacou
- Research Centre for Biomedical Engineering, City, University of London, London, United Kingdom
| |
Collapse
|
29
|
A Continuous Cuffless Blood Pressure Estimation Using Tree-Based Pipeline Optimization Tool. Symmetry (Basel) 2021. [DOI: 10.3390/sym13040686] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
High blood pressure (BP) may lead to further health complications if not monitored and controlled, especially for critically ill patients. Particularly, there are two types of blood pressure monitoring, invasive measurement, whereby a central line is inserted into the patient’s body, which is associated with infection risks. The second measurement is cuff-based that monitors BP by detecting the blood volume change at the skin surface using a pulse oximeter or wearable devices such as a smartwatch. This paper aims to estimate the blood pressure using machine learning from photoplethysmogram (PPG) signals, which is obtained from cuff-based monitoring. To avoid the issues associated with machine learning such as improperly choosing the classifiers and/or not selecting the best features, this paper utilized the tree-based pipeline optimization tool (TPOT) to automate the machine learning pipeline to select the best regression models for estimating both systolic BP (SBP) and diastolic BP (DBP) separately. As a pre-processing stage, notch filter, band-pass filter, and zero phase filtering were applied by TPOT to eliminate any potential noise inherent in the signal. Then, the automated feature selection was performed to select the best features to estimate the BP, including SBP and DBP features, which are extracted using random forest (RF) and k-nearest neighbors (KNN), respectively. To train and test the model, the PhysioNet global dataset was used, which contains 32.061 million samples for 1000 subjects. Finally, the proposed approach was evaluated and validated using the mean absolute error (MAE). The results obtained were 6.52 mmHg for SBS and 4.19 mmHg for DBP, which show the superiority of the proposed model over the related works.
Collapse
|